Sample records for arrhythmia monitoring system

  1. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  2. Automated testing of arrhythmia monitors using annotated databases.

    Science.gov (United States)

    Elghazzawi, Z; Murray, W; Porter, M; Ezekiel, E; Goodall, M; Staats, S; Geheb, F

    1992-01-01

    Arrhythmia-algorithm performance is typically tested using the AHA and MIT/BIH databases. The tools for this test are simulation software programs. While these simulations provide rapid results, they neglect hardware and software effects in the monitor. To provide a more accurate measure of performance in the actual monitor, a system has been developed for automated arrhythmia testing. The testing system incorporates an IBM-compatible personal computer, a digital-to-analog converter, an RS232 board, a patient-simulator interface to the monitor, and a multi-tasking software package for data conversion and communication with the monitor. This system "plays" patient data files into the monitor and saves beat classifications in detection files. Tests were performed using the MIT/BIH and AHA databases. Statistics were generated by comparing the detection files with the annotation files. These statistics were marginally different from those that resulted from the simulation. Differences were then examined. As expected, the differences were related to monitor hardware effects.

  3. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection.

    Science.gov (United States)

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-06-12

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan-Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.

  4. Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection †

    Science.gov (United States)

    Son, Junggab; Park, Juyoung; Oh, Heekuck; Bhuiyan, Md Zakirul Alam; Hur, Junbeom; Kang, Kyungtae

    2017-01-01

    Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities. PMID:28604628

  5. Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.

    Science.gov (United States)

    Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe

    2014-01-01

    As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.

  6. Computer-assisted education system for arrhythmia (CAESAR).

    Science.gov (United States)

    Fukushima, M; Inoue, M; Fukunami, M; Ishikawa, K; Inada, H; Abe, H

    1984-08-01

    A computer-assisted education system for arrhythmia (CAESAR) was developed for students to acquire the ability to logically diagnose complicated arrhythmias. This system has a logical simulator of cardiac rhythm using a mathematical model of the impulse formation and conduction system of the heart. A simulated arrhythmia (ECG pattern) is given on a graphic display unit with simulated series of the action potential of five pacemaker centers and the "ladder diagram" of impulse formation and conduction, which show the mechanism of that arrhythmia. For the purpose of the evaluation of this system, 13 medical students were given two types of tests concerning arrhythmias before and after 2-hr learning with this system. The scores they obtained after learning increased significantly from 73.3 +/- 11.9 to 93.2 +/- 3.0 (P less than 0.001) in one test and from 47.2 +/- 17.9 to 64.9 +/- 19.6 (P less than 0.001) in another one. These results proved that this CAI system is useful and effective for training ECG interpretation of arrhythmias.

  7. Monitoring of arrhythmia and sudden death in a hemodialysis population: The CRASH-ILR Study.

    Directory of Open Access Journals (Sweden)

    Paul R Roberts

    Full Text Available It has been suggested that sudden cardiac death (SCD contributes around 50% of cardiovascular and 27% of all-cause mortality in hemodialysis patients. The true burden of arrhythmias and arrhythmic deaths in this population, however, remains poorly characterised. Cardio Renal Arrhythmia Study in Hemodialysis (CRASH-ILR is a prospective, implantable loop recorder single centre study of 30 established hemodialysis patients and one of the first to provide long-term ambulatory ECG monitoring.30 patients (60% male aged 68±12 years receiving hemodialysis for 45±40 months with varied etiology (diabetes 37%, hypertension 23% and left ventricular ejection fraction (LVEF 55±8% received a Reveal XT implantable loop recorder (Medtronic, USA between August 2011 and October 2014. ECG data from loop recorders were transmitted at each hemodialysis session using a remote monitoring system. Primary outcome was SCD or implantation of a (tachy or bradyarrhythmia controlling device and secondary outcome, the development of arrhythmia necessitating medical intervention.During 379,512 hours of continuous ECG monitoring (mean 12,648±9,024 hours/patient, there were 8 deaths-2 SCD and 6 due to generalised deterioration/sepsis. 5 (20% patients had a primary outcome event (2 SCD, 3 pacemaker implantations for bradyarrhythmia. 10 (33% patients reached an arrhythmic primary or secondary end point. Median event free survival for any arrhythmia was 2.6 years (95% confidence intervals 1.6-3.6 years.The findings confirm the high mortality rate seen in hemodialysis populations and contrary to initial expectations, bradyarrhythmias emerged as a common and potentially significant arrhythmic event.

  8. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    International Nuclear Information System (INIS)

    Sultana, R.; Sultana, N.; Rashid, A.; Rasheed, S.Z.; Ahmed, M.; Ishaq, M.; Samad, A.

    2010-01-01

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  9. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sultana, R; Sultana, N; Rashid, A; Rasheed, S Z; Ahmed, M; Ishaq, M; Samad, A [Karachi Institute of Heart Diseases, Karachi (Pakistan)

    2010-10-15

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  10. A multiprocessor system for the analysis of cardiac arrhythmias

    International Nuclear Information System (INIS)

    Jugo, G. Diego J.

    1983-01-01

    The study presented here forms part of a real-time electrocardiographic signal analysis system project. The medical data analysis system consists of eight independent analyser units, all of which are connected to a controller unit by the standard IEEE-488 bus. Each bed is monitored by an arrhythmias analyser which has the facilities for analysing a patient's electrocardiogram automatically in real time. The measurements may be made in the presence of a pacemaker. The system described presents the technique of a separate and a simultaneous data analysis on two different ECG channels. This permit: a better diagnosis and an optimum use of the bus. (author) [fr

  11. Computers and clinical arrhythmias.

    Science.gov (United States)

    Knoebel, S B; Lovelace, D E

    1983-02-01

    Cardiac arrhythmias are ubiquitous in normal and abnormal hearts. These disorders may be life-threatening or benign, symptomatic or unrecognized. Arrhythmias may be the precursor of sudden death, a cause or effect of cardiac failure, a clinical reflection of acute or chronic disorders, or a manifestation of extracardiac conditions. Progress is being made toward unraveling the diagnostic and therapeutic problems involved in arrhythmogenesis. Many of the advances would not be possible, however, without the availability of computer technology. To preserve the proper balance and purposeful progression of computer usage, engineers and physicians have been exhorted not to work independently in this field. Both should learn some of the other's trade. The two disciplines need to come together to solve important problems with computers in cardiology. The intent of this article was to acquaint the practicing cardiologist with some of the extant and envisioned computer applications and some of the problems with both. We conclude that computer-based database management systems are necessary for sorting out the clinical factors of relevance for arrhythmogenesis, but computer database management systems are beset with problems that will require sophisticated solutions. The technology for detecting arrhythmias on routine electrocardiograms is quite good but human over-reading is still required, and the rationale for computer application in this setting is questionable. Systems for qualitative, continuous monitoring and review of extended time ECG recordings are adequate with proper noise rejection algorithms and editing capabilities. The systems are limited presently for clinical application to the recognition of ectopic rhythms and significant pauses. Attention should now be turned to the clinical goals for detection and quantification of arrhythmias. We should be asking the following questions: How quantitative do systems need to be? Are computers required for the detection of

  12. Comparison of real-time classification systems for arrhythmia detection on Android-based mobile devices.

    Science.gov (United States)

    Leutheuser, Heike; Gradl, Stefan; Kugler, Patrick; Anneken, Lars; Arnold, Martin; Achenbach, Stephan; Eskofier, Bjoern M

    2014-01-01

    The electrocardiogram (ECG) is a key diagnostic tool in heart disease and may serve to detect ischemia, arrhythmias, and other conditions. Automatic, low cost monitoring of the ECG signal could be used to provide instantaneous analysis in case of symptoms and may trigger the presentation to the emergency department. Currently, since mobile devices (smartphones, tablets) are an integral part of daily life, they could form an ideal basis for automatic and low cost monitoring solution of the ECG signal. In this work, we aim for a realtime classification system for arrhythmia detection that is able to run on Android-based mobile devices. Our analysis is based on 70% of the MIT-BIH Arrhythmia and on 70% of the MIT-BIH Supraventricular Arrhythmia databases. The remaining 30% are reserved for the final evaluation. We detected the R-peaks with a QRS detection algorithm and based on the detected R-peaks, we calculated 16 features (statistical, heartbeat, and template-based). With these features and four different feature subsets we trained 8 classifiers using the Embedded Classification Software Toolbox (ECST) and compared the computational costs for each classification decision and the memory demand for each classifier. We conclude that the C4.5 classifier is best for our two-class classification problem (distinction of normal and abnormal heartbeats) with an accuracy of 91.6%. This classifier still needs a detailed feature selection evaluation. Our next steps are implementing the C4.5 classifier for Android-based mobile devices and evaluating the final system using the remaining 30% of the two used databases.

  13. Pit-a-Pat: A Smart Electrocardiogram System for Detecting Arrhythmia.

    Science.gov (United States)

    Park, Juyoung; Lee, Kuyeon; Kang, Kyungtae

    2015-10-01

    Electrocardiogram (ECG) telemonitoring is one of the most promising applications of medical telemetry. However, previous approaches to ECG telemonitoring have largely relied on public databases of ECG results. In this article we propose a smart ECG system called Pit-a-Pat, which extracts features from ECG signals and detects arrhythmia. It is designed to run on an Android™ (Google, Mountain View, CA) device, without requiring modifications to other software. We implemented the Pit-a-Pat system using a commercial ECG device, and the experimental results demonstrate the effectiveness and accuracy of Pit-a-Pat for monitoring the ECG signal and analyzing the cardiac activity of a mobile patient. The proposed system allows monitoring of cardiac activity with automatic analysis, thereby providing a convenient, inexpensive, and ubiquitous adjunct to personal healthcare.

  14. Arrhythmia risk in liver cirrhosis

    Institute of Scientific and Technical Information of China (English)

    Ioana Mozos

    2015-01-01

    Interactions between the functioning of the heart andthe liver have been described, with heart diseasesaffecting the liver, liver diseases affecting the heart,and conditions that simultaneously affect both. Theheart is one of the most adversely affected organs inpatients with liver cirrhosis. For example, arrhythmiasand electrocardiographic changes are observed inpatients with liver cirrhosis. The risk for arrhythmia isinfluenced by factors such as cirrhotic cardiomyopathy,cardiac ion channel remodeling, electrolyte imbalances,impaired autonomic function, hepatorenal syndrome, metabolic abnormalities, advanced age, inflammatory syndrome, stressful events, impaired drug metabolism and comorbidities. Close monitoring of cirrhotic patients is needed for arrhythmias, particularly when QT intervalprolonging drugs are given, or if electrolyte imbalances or hepatorenal syndrome appear. Arrhythmia risk may persist after liver transplantation due to possible QT interval prolongation, persistence of the parasympathetic impairment, post-transplant reperfusion and chronic immunosuppression, as well as consideration of the fact that the transplant itself is a stressful event for the cardiovascular system. The aims of the present article were to provide a review of the most important data regarding the epidemiology, pathophysiology, and biomarkers of arrhythmia risk in patients with liver cirrhosis, to elucidate the association with long-term outcome, and to propose future research directions.

  15. Arrhythmia during extracorporeal shock wave lithotripsy.

    Science.gov (United States)

    Zeng, Z R; Lindstedt, E; Roijer, A; Olsson, S B

    1993-01-01

    A prospective study of arrhythmia during extracorporeal shock wave lithotripsy (ESWL) was performed in 50 patients, using an EDAP LT01 piezoelectric lithotriptor. The 12-lead standard ECG was recorded continuously for 10 min before and during treatment. One or more atrial and/or ventricular ectopic beats occurred during ESWL in 15 cases (30%). The occurrence of arrhythmia was similar during right-sided and left-sided treatment. One patient developed multifocal ventricular premature beats and ventricular bigeminy; another had cardiac arrest for 13.5 s. It was found that various irregularities of the heart rhythm can be caused even by treatment with a lithotriptor using piezoelectric energy to create the shock wave. No evidence was found, however, that the shock wave itself rather than vagal activation and the action of sedo-analgesia was the cause of the arrhythmia. For patients with severe underlying heart disease and a history of complex arrhythmia, we suggest that the ECG be monitored during treatment. In other cases, we have found continuous monitoring of oxygen saturation and pulse rate with a pulse oximeter to be perfectly reliable for raising the alarm when depression of respiration and vaso-vagal reactions occur.

  16. Understand Your Risk for Arrhythmia

    Science.gov (United States)

    ... is likely monitoring your heart rhythm with regular EKGs ( electrocardiograms ). But arrhythmias that occur infrequently may not ... patient sheets Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  17. Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

    Directory of Open Access Journals (Sweden)

    Umair Aziz

    2015-12-01

    Full Text Available Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from July 2013 to November 2014 were included. On admission, twelve-lead electrocardiogram (ECG was performed for all patients. During admission, all patients underwent continuous cardiac monitoring using a cardiac monitor. If an arrhythmia was suspected on the cardiac monitor, another ECG was obtained immediately.  Results: During the study period, 100 patients with AlP poisoning (63% men were treated at Allied Hospital Faisalabad. Mean age of the patients was 26.7 ± 7.9 years ranging from 16 to 54 years. Tachycardia was detected in 68 patients and bradycardia in 12 patients. Hypotension was observed in 75 patients. Eighty patients developed cardiac arrhythmia. The most frequent arrhythmia was atrial fibrillation (31% of patients followed by ventricular fibrillation (20%, ventricular tachycardia (17%, 3rd degree AV block (7% and 2nd degree AV block (5%. In total, 78 patients died, depicting a 78% mortality rate following wheat pill poisoning. Among those who died, seventy-one patients had cardiac arrhythmia. Comparison of death rate between patients with and without cardiac arrhythmia showed a significant difference (71/80 (88.8% vs. 7/20 (35%; P < 0.001.  Conclusion: Wheat pill poisoning causes a very high mortality, and circulatory collapse is the major cause of death among these patients. Most of the patients with AlP poisoning develop cardiac arrhythmias which are invariably life threatening. Early detection of cardiac disorders and proper management of arrhythmias may reduce mortalities.

  18. Evaluation of heart rhythm variability and arrhythmia in children with systemic and localized scleroderma.

    Science.gov (United States)

    Wozniak, Jacek; Dabrowski, Rafal; Luczak, Dariusz; Kwiatkowska, Malgorzata; Musiej-Nowakowska, Elzbieta; Kowalik, Ilona; Szwed, Hanna

    2009-01-01

    To evaluate possible disturbances in autonomic regulation and cardiac arrhythmias in children with localized and systemic scleroderma. There were 40 children included in the study: 20 with systemic and 20 with localized scleroderma. The control group comprised 20 healthy children. In 24-hour Holter recording, the average rate of sinus rhythm was significantly higher in the groups with systemic and localized scleroderma than in the control group, but there was no significant difference between them. The variability of heart rhythm in both groups was significantly decreased. In the group with systemic scleroderma, single supraventricular ectopic beats were observed in 20% and runs were seen in 40% of patients. In the group with localized scleroderma, supraventricular single ectopic beats occurred in 35% of patients and runs in 45% of those studied. Ventricular arrhythmia occurred in 2 children with systemic scleroderma, but in 1 child, it was complex. The most frequent cardiac arrhythmias in both types of scleroderma in children were of supraventricular origin, whereas ventricular arrhythmias did not occur very often. There were no significant differences in autonomic disturbances manifesting as a higher heart rate and decreased heart rate variability between localized and systemic scleroderma.

  19. Arrhythmias in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Gaurav Agarwal

    2017-01-01

    Full Text Available Chronic hyperglycaemia of Type 2 diabetes mellitus causes long term damage to heart resulting in coronary artery disease (CAD, myocardial infarction (MI, congestive heart failure (CHF, and sudden death from arrhythmias. AIMS: To study the prevalence of different types of arrhythmias in T2DM, particularly in association with Cardiac Autonomic Neuropathy (CAN. METHODS: A cross-sectional study including 100 patients of Type 2 Diabetes Mellitus (T2DM presenting with cardiac arrhythmias, was done at our hospital over 2 years. Detailed history along with physical examination and tests for CAN were done. Routine investigations along with echocardiography, stress test, Holter monitoring were done. RESULTS: Sinus Tachycardia (ST was the commonest arrhythmia, found in 32% of patients. 20% had Complete Heart Block (CHB, 15% had Sinus Bradycardia (SB, and 15% had Atrial Fibrillation (AF. Ventricular Premature Complex (VPC was found in 10% and 3% had Atrial Premature Complex (APC. 3% had first degree AV block, whereas 1% had Paroxysmal Supra Ventricular Tachycardia (PSVT, and another 1% had Ventricular Tachycardia (VT. Poorly controlled diabetes and co-morbidities was associated with higher incidence of arrhythmias. 62% of patients had prolonged QTc, majority of which had CAN. Most of the patients responded to standard therapy.

  20. Multi-arrhythmias detection with an XML rule-based system from 12-Lead Electrocardiogram.

    Science.gov (United States)

    Khelassi, Abdeldjalil; Yelles-Chaouche, Sarra-Nassira; Benais, Faiza

    2017-05-01

    The computer-aided detection of cardiac arrhythmias stills a crucial application in medical technologies. The rule based systems RBS ensure a high level of transparency and interpretability of the obtained results. To facilitate the diagnosis of the cardiologists and to reduce the uncertainty made in this diagnosis. In this research article, we have realized a classification and automatic recognition of cardiac arrhythmias, by using XML rules that represent the cardiologist knowledge. Thirteen experiments with different knowledge bases were realized for improving the performance of the used method in the detection of 13 cardiac arrhythmias. In the first 12 experiments, we have designed a specialized knowledge base for each cardiac arrhythmia, which contains just one arrhythmia detection rule. In the last experiment, we applied the knowledge base which contains rules of 12 arrhythmias. We used, for the experiments, an international data set with 279 features and 452 records characterizing 12 leads of ECG signal and social information of patients. The data sets were constructed and published at Bilkent University of Ankara, Turkey. In addition, the second version of the self-developed software "XMLRULE" was used; the software can infer more than one class and facilitate the interpretability of the obtained results. The 12 first experiments give 82.80% of correct detection as the mean of all experiments, the results were between 19% and 100% with a low rate in just one experiment. The last experiment in which all arrhythmias are considered, the results of correct detection was 38.33% with 90.55% of sensibility and 46.24% of specificity. It was clearly show that in these results the good choice of the classification model is very beneficial in terms of performance. The obtained results were better than the published results with other computational methods for the mono class detection, but it was less in multi-class detection. The RBS is the most transparent method for

  1. Arrhythmias

    Science.gov (United States)

    ... some herbal remedies); injuries to the heart from chest trauma or heart surgery; use of illegal drugs, alcohol, or tobacco; caffeine; and stress. Arrhythmias also can happen for no apparent reason. Signs and ... of breath chest pain fainting Arrhythmias can ...

  2. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    Directory of Open Access Journals (Sweden)

    Hongqiang Li

    2016-10-01

    Full Text Available Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  3. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  4. β1-Adrenoceptor blocker aggravated ventricular arrhythmia.

    Science.gov (United States)

    Wang, Yan; Patel, Dimpi; Wang, Dao Wu; Yan, Jiang Tao; Hsia, Henry H; Liu, Hao; Zhao, Chun Xia; Zuo, Hou Juan; Wang, Dao Wen

    2013-11-01

    To assess the impact of β1 -adrenoceptor blockers (β1 -blocker) and isoprenaline on the incidence of idiopathic repetitive ventricular arrhythmia that apparently decreases with preprocedural anxiety. From January 2010 to July 2012, six patients were identified who had idiopathic ventricular arrhythmias that apparently decreased (by greater than 90%) with preprocedural anxiety. The number of ectopic ventricular beats per hour (VPH) was calculated from Holter or telemetry monitoring to assess the ectopic burden. The mean VPH of 24 hours from Holter before admission (VPH-m) was used as baseline (100%) for normalization. β1 -Blockers, isoprenaline, and/or aminophylline were administrated successively on the ward and catheter lab to evaluate their effects on the ventricular arrhythmias. Among 97 consecutive patients with idiopathic ventricular arrhythmias, six had reduction in normalized VPHs in the hour before the scheduled procedure time from (104.6 ± 4.6%) to (2.8 ± 1.6%) possibly due to preprocedural anxiety (P < 0.05), then increased to (97.9 ± 9.7%) during β1 -blocker administration (P < 0.05), then quickly reduced to (1.6 ± 1.0%) during subsequent isoprenaline infusion. Repeated β1 -blocker quickly counteracted the inhibitory effect of isoprenaline, and VPHs increased to (120.9 ± 2.4%) from (1.6 ± 1.0%; P < 0.05). Isoprenaline and β1 -blocker showed similar effects on the arrhythmias in catheter lab. In some patients with structurally normal heart and ventricular arrhythmias there is a marked reduction of arrhythmias associated with preprocedural anxiety. These patients exhibit a reproducible sequence of β1 -blocker aggravation and catecholamine inhibition of ventricular arrhythmias, including both repetitive ventricular premature beats and monomorphic ventricular tachycardia. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  5. Non-sedating antihistamine drugs and cardiac arrhythmias -- biased risk estimates from spontaneous reporting systems?

    DEFF Research Database (Denmark)

    De Bruin, M L; van Puijenbroek, E P; Egberts, A C G

    2002-01-01

    AIMS: This study used spontaneous reports of adverse events to estimate the risk for developing cardiac arrhythmias due to the systemic use of non-sedating antihistamine drugs and compared the risk estimate before and after the regulatory action to recall the over-the-counter status of some...... of these drugs. METHODS: All suspected adverse drug reactions (ADRs) reported until July 1999 to the Netherlands Pharmacovigilance Foundation Lareb were used to calculate the ADR reporting odds ratio, defined as the ratio of exposure odds among reported arrhythmia cases, to the exposure odds of other ADRs (non......-sedating antihistamines. In general non-sedating antihistamines are associated with cardiac arrhythmia to a higher extent in comparison with other drugs (ADR reporting odds ratio 2.05 [95% CI: 1.45, 2.89]). The association between arrhythmias and non-sedating antihistamine drugs calculated before 1998...

  6. Arrhythmias and hemodialysis: role of potassium and new diagnostic tools.

    Science.gov (United States)

    Buemi, Michele; Coppolino, Giuseppe; Bolignano, Davide; Sturiale, Alessio; Campo, Susanna; Buemi, Antoine; Crascì, Eleonora; Romeo, Adolfo

    2009-01-01

    Cardiovascular diseases represent the main causes of death in patients affected by renal failure, and arrhythmias are frequently observed in patients undergoing hemodialysis. Dialytic treatment per se can be considered as an arrhythmogenic stimulus; moreover, uraemic patients are characterized by a "pro-arrhythmic substrate" because of the high prevalence of ischaemic heart disease, left ventricular hypertrophy and autonomic neuropathy. One of the most important pathogenetic element involved in the onset of intra-dialytic arrhythmias is the alteration in electrolytes concentration, particularly calcium and potassium. It may be very useful to monitor the patient's cardiac activity during the whole hemodilaytic session. Nevertheless, the application of an extended intradialytic electrocardiographic monitoring is not simple because of several technical and structural impairments. We tried to overcome these difficulties using Whealthy, a wearable system consisting in a t-shirt composed of conductors and piezoresistive materials, integrated to form fibers and threads connected to tissutal sensors, electrodes, and connectors. ECG and pneumographic impedance signals are acquired by the electrodes in the tissue, and the data are registered by a small computer and transmitted via GPRS or Bluetooth.

  7. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    Directory of Open Access Journals (Sweden)

    Bohui Zhu

    2013-01-01

    Full Text Available This paper presents a novel maximum margin clustering method with immune evolution (IEMMC for automatic diagnosis of electrocardiogram (ECG arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias.

  8. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    Science.gov (United States)

    Chakraborty, Monisha; Ghosh, Dipak

    2018-04-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  9. Patient characteristics associated with false arrhythmia alarms in intensive care

    Directory of Open Access Journals (Sweden)

    Harris PR

    2017-04-01

    Full Text Available Patricia R Harris,1,2 Jessica K Zègre-Hemsey,3,4 Daniel Schindler,5 Yong Bai,6 Michele M Pelter,2,7 Xiao Hu2,8 1Department of Nursing, School of Health and Natural Sciences, Dominican University of California, San Rafael, 2Department of Physiological Nursing, School of Nursing, University of California, San Francisco, CA, 3School of Nursing, 4Department of Emergency Medicine, School of Medicine, University of North Carolina at Chapel Hill, NC, 5Intensive Care Unit, The Neuroscience Center, Sutter Eden Medical Center, Castro Valley, 6Hu Research Laboratory, Department of Physiological Nursing, School of Nursing, University of California, San Francisco, 7ECG Monitoring Research Lab, Department of Physiological Nursing, School of Nursing, 8Physiological Nursing and Neurological Surgery, Affiliate Faculty of Institute for Computational Health Sciences Core Faculty UCB/UCSF Joint Bio-Engineering Graduate Program, University of California, San Francisco, CA, USA Introduction: A high rate of false arrhythmia alarms in the intensive care unit (ICU leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms. Objective: The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU. Methods: This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and

  10. Qt interval prolongation and ventricular arrhythmias in patients with chronic heart failure

    International Nuclear Information System (INIS)

    Sarwar, M.; Majeed, S.M.I.; Khan, M.A.; Majeed, S.M.

    2014-01-01

    To determine the association of QTc interval prolongation with ventricular arrhythmias in patients with chronic heart failure. Study Design: Descriptive study. Place and Duration of Study: This study was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases, Rawalpindi, Pakistan from April 2013 to August 2013. Patients and Methods: Fifty three heart failure patients were monitored for 48 hours using ambulatory holter electrocardiography recorders. Digital ECG data was analyzed for QTc interval along with frequency and severity of arrhythmias. Association of prolonged QTc interval with ventricular arrhythmias and severity of arrhythmias was analyzed. Results: Cardiac arrhythmias were observed in 79.2% patients. QT analysis revealed that 69.8% patients had prolonged QTc interval, 86.4% patients with prolonged QTc had ventricular arrhythmias. Of these 66% patients were found to have severe ventricular arrhythmias. Comparison of mean QTc interval of our study population with a reference value showed significantly higher QTc interval of our study group than the test value. Conclusion: Arrhythmia frequency and severity significantly increases with an increase in QTc interval in heart failure demonstrating association of prolonged QTc interval with high risk of severe ventricular arrhythmias and sudden cardiac death in chronic heart failure. (author)

  11. Hypertension and cardiac arrhythmias

    DEFF Research Database (Denmark)

    Lip, Gregory Y.H.; Coca, Antonio; Kahan, Thomas

    2017-01-01

    Hypertension is a common cardiovascular risk factor leading to heart failure (HF), coronary artery disease, stroke, peripheral artery disease and chronic renal insufficiency. Hypertensive heart disease can manifest as many cardiac arrhythmias, most commonly being atrial fibrillation (AF). Both...... supraventricular and ventricular arrhythmias may occur in hypertensive patients, especially in those with left ventricular hypertrophy (LVH) or HF. Also, some of the antihypertensive drugs commonly used to reduce blood pressure, such as thiazide diuretics, may result in electrolyte abnormalities (e.g. hypokalaemia......, hypomagnesemia), further contributing to arrhythmias, whereas effective control of blood pressure may prevent the development of the arrhythmias such as AF. In recognizing this close relationship between hypertension and arrhythmias, the European Heart Rhythm Association (EHRA) and the European Society...

  12. Arrhythmias (For Parents)

    Science.gov (United States)

    ... some herbal remedies ); injuries to the heart from chest trauma or heart surgery; use of illegal drugs, alcohol, or tobacco; caffeine; and stress. Arrhythmias can be temporary or permanent. An ... of breath chest pain fainting Arrhythmias can ...

  13. Calcium-dependent arrhythmias in transgenic mice with heart failure.

    Science.gov (United States)

    London, Barry; Baker, Linda C; Lee, Joon S; Shusterman, Vladimir; Choi, Bum-Rak; Kubota, Toru; McTiernan, Charles F; Feldman, Arthur M; Salama, Guy

    2003-02-01

    Transgenic mice overexpressing the inflammatory cytokine tumor necrosis factor (TNF)-alpha (TNF-alpha mice) in the heart develop a progressive heart failure syndrome characterized by biventricular dilatation, decreased ejection fraction, atrial and ventricular arrhythmias on ambulatory telemetry monitoring, and decreased survival compared with nontransgenic littermates. Programmed stimulation in vitro with single extra beats elicits reentrant ventricular arrhythmias in TNF-alpha (n = 12 of 13 hearts) but not in control hearts. We performed optical mapping of voltage and Ca(2+) in isolated perfused ventricles of TNF-alpha mice to study the mechanisms that lead to the initiation and maintenance of the arrhythmias. When compared with controls, hearts from TNF-alpha mice have prolonged of action potential durations (action potential duration at 90% repolarization: 23 +/- 2 ms, n = 7, vs. 18 +/- 1 ms, n = 5; P < 0.05), no increased dispersion of refractoriness between apex and base, elevated diastolic and depressed systolic [Ca(2+)], and prolonged Ca(2+) transients (72 +/- 6 ms, n = 10, vs. 54 +/- 5 ms, n = 8; P < 0.01). Premature beats have diminished action potential amplitudes and conduct in a slow, heterogeneous manner. Lowering extracellular [Ca(2+)] normalizes conduction and prevents inducible arrhythmias. Thus both action potential prolongation and abnormal Ca(2+) handling may contribute to the initiation of reentrant arrhythmias in this heart failure model by mechanisms distinct from enhanced dispersion of refractoriness or triggered activity.

  14. Automatic recognition of cardiac arrhythmias based on the geometric patterns of Poincaré plots

    International Nuclear Information System (INIS)

    Zhang, Lijuan; Guo, Tianci; Xi, Bin; Fan, Yang; Wang, Kun; Bi, Jiacheng; Wang, Ying

    2015-01-01

    The Poincaré plot emerges as an effective tool for assessing cardiovascular autonomic regulation. It displays nonlinear characteristics of heart rate variability (HRV) from electrocardiographic (ECG) recordings and gives a global view of the long range of ECG signals. In the telemedicine or computer-aided diagnosis system, it would offer significant auxiliary information for diagnosis if the patterns of the Poincaré plots can be automatically classified. Therefore, we developed an automatic classification system to distinguish five geometric patterns of the Poincaré plots from four types of cardiac arrhythmias. The statistics features are designed on measurements and an ensemble classifier of three types of neural networks is proposed. Aiming at the difficulty to set a proper threshold for classifying the multiple categories, the threshold selection strategy is analyzed. 24 h ECG monitoring recordings from 674 patients, which have four types of cardiac arrhythmias, are adopted for recognition. For comparison, Support Vector Machine (SVM) classifiers with linear and Gaussian kernels are also applied. The experiment results demonstrate the effectiveness of the extracted features and the better performance of the designed classifier. Our study can be applied to diagnose the corresponding sinus rhythm and arrhythmia substrates disease automatically in the telemedicine and computer-aided diagnosis system. (paper)

  15. Sleep Apnea and Nocturnal Cardiac Arrhythmia: A Populational Study

    Directory of Open Access Journals (Sweden)

    Fatima Dumas Cintra

    2014-11-01

    Full Text Available Background: The mechanisms associated with the cardiovascular consequences of obstructive sleep apnea include abrupt changes in autonomic tone, which can trigger cardiac arrhythmias. The authors hypothesized that nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea. Objective: To analyze the relationship between obstructive sleep apnea and abnormal heart rhythm during sleep in a population sample. Methods: Cross-sectional study with 1,101 volunteers, who form a representative sample of the city of São Paulo. The overnight polysomnography was performed using an EMBLA® S7000 digital system during the regular sleep schedule of the individual. The electrocardiogram channel was extracted, duplicated, and then analyzed using a Holter (Cardio Smart® system. Results: A total of 767 participants (461 men with a mean age of 42.00 ± 0.53 years, were included in the analysis. At least one type of nocturnal cardiac rhythm disturbance (atrial/ventricular arrhythmia or beat was observed in 62.7% of the sample. The occurrence of nocturnal cardiac arrhythmias was more frequent with increased disease severity. Rhythm disturbance was observed in 53.3% of the sample without breathing sleep disorders, whereas 92.3% of patients with severe obstructive sleep apnea showed cardiac arrhythmia. Isolated atrial and ventricular ectopy was more frequent in patients with moderate/severe obstructive sleep apnea when compared to controls (p < 0.001. After controlling for potential confounding factors, age, sex and apnea-hypopnea index were associated with nocturnal cardiac arrhythmia. Conclusion: Nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea and the prevalence increases with disease severity. Age, sex, and the Apnea-hypopnea index were predictors of arrhythmia in this sample.

  16. QTc-prolonging drugs and hospitalizations for cardiac arrhythmias

    DEFF Research Database (Denmark)

    De Bruin, Marie L; Hoes, Arno W; Leufkens, Hubert G M

    2003-01-01

    Cardiac arrhythmia as an adverse effect of noncardiac drugs has been an issue of growing importance during the past few years. In this population-based study, we evaluated the risk for serious cardiac arrhythmias during the use of several noncardiac QTc-prolonging drugs in day-to-day practice......, and subsequently focused on several specific groups of patients who could be extremely vulnerable for drug-induced arrhythmias. We performed a case-control study in which patients (cases), hospitalized for nonatrial cardiac arrhythmias from 1987 to 1998, were compared with their matched controls regarding current...... use of QTc-prolonging drugs. Odds ratios (OR) and 95% confidence intervals (CI) were calculated using multivariate conditional logistic regression, adjusting for potential confounding factors. Data were obtained from the PHARMO record linkage system. We identified 501 cases, 39 of whom used QTc...

  17. Obstructive sleep apnoea-hypopnoea and arrhythmias: new updates.

    Science.gov (United States)

    Vizzardi, Enrico; Sciatti, Edoardo; Bonadei, Ivano; D'Aloia, Antonio; Curnis, Antonio; Metra, Marco

    2017-07-01

    Obstructive sleep apnoea-hypopnoea (OSAH) is a prevalent condition characterized by repetitive pharyngeal collapse during sleep, leading to hypoxemia, hypercapnia, and persistent inspiratory efforts against an occluded airway until arousal. Several studies demonstrated that OSAH exerts acute and chronic effects on the cardiovascular system. Thus, although being a respiratory problem, the most important consequences of OSAH are cardiovascular, among which there are arrhythmias. The purpose of this review is to systematically analyse what has been recently published about the relationship between OSAH and every cardiac arrhythmia separately. We searched Pubmed, Scopus, Web of Science and Cochrane Collaboration databases for 'OSAHS arrhythmias', 'OSAH arrhythmias' and 'OSA arrhythmias'. We analyse 1298 articles and meta-analyses, excluding already edited reviews. Arrhythmias, especially of ventricular origin, are frequent in OSAH. Ventricular premature beats, couplets and ventricular tachycardia runs are even more frequent in patients suffering from heart failure. They may be due to left heart remodelling, overwork and ischaemia and can explain at least some sudden deaths occurring between midnight and 6 a.m. Sinus pauses and atrioventricular blocks are increased according to the severity of the disturbance and may be reduced by continuous positive airway pressure therapy, preventing pace-maker implantation. Finally, atrial fibrillation, resistance against antiarrhythmic drugs and recurrences after surgical procedures are strongly related to OSAH. Arrhythmias are frequent in OSAH. Treatment of OSAH may reduce some of them. An implantable cardioverter-defibrillator and continuous positive airway pressure should be considered in some patients.

  18. Ventricular arrhythmias in Chagas disease

    Directory of Open Access Journals (Sweden)

    Marco Paulo Tomaz Barbosa

    2015-02-01

    Full Text Available Sudden death is one of the most characteristic phenomena of Chagas disease, and approximately one-third of infected patients develop life-threatening heart disease, including malignant ventricular arrhythmias. Fibrotic lesions secondary to chronic cardiomyopathy produce arrhythmogenic substrates that lead to the appearance and maintenance of ventricular arrhythmias. The objective of this study is to discuss the main clinical and epidemiological aspects of ventricular arrhythmias in Chagas disease, the specific workups and treatments for these abnormalities, and the breakthroughs needed to determine a more effective approach to these arrhythmias. A literature review was performed via a search of the PubMed database from 1965 to May 31, 2014 for studies of patients with Chagas disease. Clinical management of patients with chronic Chagas disease begins with proper clinical stratification and the identification of individuals at a higher risk of sudden cardiac death. Once a patient develops malignant ventricular arrhythmia, the therapeutic approach aims to prevent the recurrence of arrhythmias and sudden cardiac death by the use of implantable cardioverter defibrillators, antiarrhythmic drugs, or both. In select cases, invasive ablation of the reentrant circuit causing tachycardia may be useful. Ventricular arrhythmias are important manifestations of Chagas cardiomyopathy. This review highlights the absence of high-quality evidence regarding the treatment of ventricular arrhythmias in Chagas disease. Recognizing high-risk patients who require specific therapies, especially invasive procedures such as the implantation of cardioverter defibrillators and ablative approaches, is a major challenge in clinical practice.

  19. Sports and arrhythmias: a report of the International Workshop Venice Arrhythmias 2009.

    Science.gov (United States)

    Giada, Franco; Biffi, Alessandro; Cannom, David S; Cappato, Riccardo; Capucci, Alessandro; Corrado, Domenico; Delise, Pietro; Drezner, Jonathan A; El-Sherif, Nabil; Estes, Mark; Furlanello, Francesco; Heidbuchel, Hein; Inama, Giuseppe; Lindsay, Bruce D; Maron, Barry J; Maron, Martin S; Mont, Luis; Olshansky, Brian; Pelliccia, Antonio; Thiene, Gaetano; Viskin, Sami; Zeppilli, Paolo; Natale, Andrea; Raviele, Antonio

    2010-10-01

    This article is a report of an international symposium, endorsed by the Section on Sports Cardiology of the European Association for Cardiovascular Prevention and Rehabilitation, the Italian Society of Sports Cardiology, and the Italian Federation of Sports Medicine, which was held within the 11th International Workshop on Cardiac Arrhythmias (Venice Arrhythmias 2009, Venice, Italy, October 2009). The following main topics were discussed during the symposium: the role of novel diagnostic examinations to assess the risk of sudden death in athletes, controversies on arrhythmic risk evaluation in athletes, controversies on the relationship between sports and arrhythmias, and controversies on antiarrhythmic treatment in athletes.

  20. Pharmacogenetics of drug-induced arrhythmias

    DEFF Research Database (Denmark)

    De Bruin, Marie L; van Puijenbroek, Eugene P; Bracke, Madelon

    2006-01-01

    PURPOSE: The bottleneck in pharmacogenetic research on rare adverse drug reactions (ADR) is retrieval of patients. Spontaneous reports of ADRs may form a useful source of patients. We investigated the feasibility of a pharmacogenetic study, in which cases were selected from the database...... of a spontaneous reporting system for ADRs, using drug-induced arrhythmias as an example. METHODS: Reports of drug-induced arrhythmias to proarrhythmic drugs were selected from the database of the Netherlands Pharmacovigilance Centre (1996-2003). Information on the patient's general practitioner (GP) was obtained...... be included in the study, giving an overall participation rate of 9% (4/45). The main reason for GPs not being willing to participate was lack of time. Variants were identified in KCNH2, SCN5A and KCNE1. CONCLUSIONS: Spontaneous reporting systems for ADRs may be used for pharmacogenetic research. The methods...

  1. Arrhythmias

    Science.gov (United States)

    ... sign of other heart problems, or an immediate danger to your health. ... patient with suspected arrhythmia. In: Goldman L, Schafer AI, eds. Goldman’s Cecil Medicine . 25th ed. Philadelphia, PA: ...

  2. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    Science.gov (United States)

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  3. Features of conngestive heart failure development in patients with post infarct cardiosclerosis concomitant with arrhythmias

    International Nuclear Information System (INIS)

    Zharov, E.I.; Martynov, A.I.; Vertkin, A.L.; Sergeeva, L.I.; Sedov, V.P.

    1989-01-01

    Two hundred and seventy seven patients with coronary heart disease, includng 182 with postinfarction cardiosclerosis undewent 24-hour Holter monitoring. A significant correlation was found between the number of coupled ventricular arrhythmias, ventricular tachycardia paroxysms and developmet of congestive heart failure in patients with postinfarct cardiosclerosis. With evolving metabolic deficiency as evidenced by thallium-201 myocardial scintigraphy, the incidence of congestive heart failure and ventricular arrhythmias increased among the patients

  4. Monitor of cardiac events implemented in PDA platform

    International Nuclear Information System (INIS)

    Bustamante, John; Saenz, Jose F; Amaya, Adrian

    2007-01-01

    Ambulatory monitoring of electrocardiac events constitutes a valuable tool in the diagnosis of cardiac arrhythmias involved in pathologic processes such as myocardiopathies, post-infarction stages, autonomous cardiac system injuries, etc.; unfortunately, its extensive use is not possible yet, due to the high costs that imply the acquisition of these equipment. For this purpose, through the utilization of personal digital assistants, a monitor of cardiac events with pre and post-symptomatic recording capacity, electrocardiographic signal visualization in real time, automatic recording of bradycardias and tachycardias and the possibility of annotation of symptoms by the patient, is designed and developed. It consists of a hardware component for the acquisition and treatment of the signals, software for the monitoring in Palm OSO platform and an appliance for the discharge and analysis of the stored data. Prototype validations were realized through an electrocardiographic simulator, an arrhythmia simulator Based on arrhythmia data base registers of the Massachusetts Institute of Technology and 8eth Israel Hospital and on pilot tests of healthy people and of patients with arrhythmias. In this preliminary report, we show the way in which the developed prototype constitutes a viable alternative for ambulatory monitoring of arrhythmia, taking advantages of the storage capacity, processing and visualization that have the actual digital assistances with the additional advantages that its use is not restricted to only one utility and its economic accessibility is facilitated due to its wide commercial availability

  5. Automated system for ST segment and arrhythmia analysis in exercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hsia, P.W.; Jenkins, J.M.; Shimoni, Y.; Gage, K.P.; Santinga, J.T.; Pitt, B.

    1986-01-01

    A computer-based system for interpretation of the electrocardiogram (ECG) in the diagnosis of arrhythmia and ST segment abnormality in an exercise system is presented. The system was designed for inclusion in a gamma camera so the ECG diagnosis could be combined with the diagnostic capability of radionuclide ventriculography. Digitized data are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is provided. Each beat is assigned a beat code based on a combination of waveform analysis and RR interval measurement. The waveform analysis employs a new correlation coefficient formula which corrects for baseline wander. Selective signal averaging, in which only normal beats are included, is done for an improved signal-to-noise ratio prior to ST segment analysis. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate have all been automated. ST level and slope measurements are computed on signal-averaged data. Arrhythmia analysis of 13 passages of abnormal rhythm by computer was found to be correct in 98.4 percent of all beats. 25 passages of exercise data, 1-5 min in length, were evaluated by the cardiologist and found to be in agreement in 95.8 percent in measurements of ST level and 91.7 percent in measurements of ST slope

  6. In Search of Hidden Arrhythmia

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2015-10-01

    Full Text Available Cardiac rhythm disorders could be very common and minimal significance like isolated ventricular ectopics are very serious and life threatening like ventricular tachycardia or fibrillation. Often it is an irregular pulse or heart beats which calls our attention to the presence of cardiac rhythm disorders. But many times, cardiac arrhythmia is intermittent and not manifest at the time of physical examination. A simple 12 lead electrocardiogram with a long rhythm strip can document cardiac arrhythmia which is frequent, but often fails to record intermittent arrhythmia which can still be quite symptomatic and sometimes life threatenting. This brief review is on the various modalities of electrocardiographic recordings used for documenting arrhythmia which is not easily documented by a 12 lead electrocardiogram with a long rhythm strip.

  7. Carbon monoxide induces cardiac arrhythmia via induction of the late Na+ current.

    Science.gov (United States)

    Dallas, Mark L; Yang, Zhaokang; Boyle, John P; Boycott, Hannah E; Scragg, Jason L; Milligan, Carol J; Elies, Jacobo; Duke, Adrian; Thireau, Jérôme; Reboul, Cyril; Richard, Sylvain; Bernus, Olivier; Steele, Derek S; Peers, Chris

    2012-10-01

    Clinical reports describe life-threatening cardiac arrhythmias after environmental exposure to carbon monoxide (CO) or accidental CO poisoning. Numerous case studies describe disruption of repolarization and prolongation of the QT interval, yet the mechanisms underlying CO-induced arrhythmias are unknown. To understand the cellular basis of CO-induced arrhythmias and to identify an effective therapeutic approach. Patch-clamp electrophysiology and confocal Ca(2+) and nitric oxide (NO) imaging in isolated ventricular myocytes was performed together with protein S-nitrosylation to investigate the effects of CO at the cellular and molecular levels, whereas telemetry was used to investigate effects of CO on electrocardiogram recordings in vivo. CO increased the sustained (late) component of the inward Na(+) current, resulting in prolongation of the action potential and the associated intracellular Ca(2+) transient. In more than 50% of myocytes these changes progressed to early after-depolarization-like arrhythmias. CO elevated NO levels in myocytes and caused S-nitrosylation of the Na(+) channel, Na(v)1.5. All proarrhythmic effects of CO were abolished by the NO synthase inhibitor l-NAME, and reversed by ranolazine, an inhibitor of the late Na(+) current. Ranolazine also corrected QT variability and arrhythmias induced by CO in vivo, as monitored by telemetry. Our data indicate that the proarrhythmic effects of CO arise from activation of NO synthase, leading to NO-mediated nitrosylation of Na(V)1.5 and to induction of the late Na(+) current. We also show that the antianginal drug ranolazine can abolish CO-induced early after-depolarizations, highlighting a novel approach to the treatment of CO-induced arrhythmias.

  8. Non-sedating antihistamine drugs and cardiac arrhythmias -- biased risk estimates from spontaneous reporting systems?

    DEFF Research Database (Denmark)

    De Bruin, M L; van Puijenbroek, E P; Egberts, A C G

    2002-01-01

    of these drugs. METHODS: All suspected adverse drug reactions (ADRs) reported until July 1999 to the Netherlands Pharmacovigilance Foundation Lareb were used to calculate the ADR reporting odds ratio, defined as the ratio of exposure odds among reported arrhythmia cases, to the exposure odds of other ADRs (non......-sedating antihistamines. In general non-sedating antihistamines are associated with cardiac arrhythmia to a higher extent in comparison with other drugs (ADR reporting odds ratio 2.05 [95% CI: 1.45, 2.89]). The association between arrhythmias and non-sedating antihistamine drugs calculated before 1998...

  9. Lysophosphatidylcholine (LPC) metabolism and cardiac arrhythmias

    International Nuclear Information System (INIS)

    Giffin, D.M.; Man, R.Y.K.; Arthur, G.; Choy, P.C.

    1986-01-01

    The effect of LPC in the production of cardiac arrhythmias in isolated mammalian hearts has been well-documented. Cardiac arrhythmias are initiated by the accumulation of the lysolipid in the cardiac membrane. When isolated rat hearts were perfused in 10 μM LPC for 10 min, severe arrhythmias were observed in all experiments. In isolated guinea pig hearts that were perfused under identical conditions, the development of severe arrhythmias was never observed, and mild arrhythmias were produced in less than 50% of the hearts used. When the hearts of both species were perfused with [ 14 C-palmitate]-LPC, the labellings found in the microsomal fractions (expressed in mg protein) were similar. However, a higher amount of labelled LPC (2-fold) was found in rat heart microsomes, whereas a higher amount of labelled fatty acid was located in the guinea pig heart microsomes. Determination of lysophospholipase activities in these microsomal fractions revealed that the specific activity of the enzyme was much higher in the guinea pig heart than the rat heart. The authors conclude that the differential effect of LPC-induced arrhythmias between the rat and guinea pig heart may be a direct result of the lysophospholipase activities in these hearts. The ability to catabolize LPC more rapidly in the guinea pig heart may decrease the accumulation of LPC in the membrane, and hence, reduce the production of arrhythmias

  10. Andrographolide inhibits arrhythmias and is cardioprotective in rabbits.

    Science.gov (United States)

    Zeng, Mengliu; Jiang, Wanzhen; Tian, Youjia; Hao, Jie; Cao, Zhenzhen; Liu, Zhipei; Fu, Chen; Zhang, Peihua; Ma, Jihua

    2017-09-22

    Andrographolide has a protective effect on the cardiovascular system. To study its cardic-electrophysiological effects, action potentials and voltage-gated Na + (I Na ), Ca 2+ (I CaL ), and K + (I K1 , I Kr , I to and I Kur ) currents were recorded using whole-cell patch clamp and current clamp techniques. Additionally, the effects of andrographolide on aconitine-induced arrhythmias were assessed on electrocardiograms in vivo . We found that andrographolide shortened action potential duration and reduced maximum upstroke velocity in rabbit left ventricular and left atrial myocytes. Andrographolide attenuated rate-dependence of action potential duration, and reduced or abolished delayed afterdepolarizations and triggered activities induced by isoproterenol (1 μM) and high calcium ([Ca 2+ ] o =3.6 mM) in left ventricular myocytes. Andrographolide also concentration-dependently inhibited I Na and I CaL , but had no effect on I to , I Kur , I K1 , or I Kr in rabbit left ventricular and left atrial myocytes. Andrographolide treatment increased the time and dosage thresholds of aconitine-induced arrhythmias, and reduced arrhythmia incidence and mortality in rabbits. Our results indicate that andrographolide inhibits cellular arrhythmias (delayed afterdepolarizations and triggered activities) and aconitine-induced arrhythmias in vivo , and these effects result from I Na and I CaL inhibition. Andrographolide may be useful as a class I and IV antiarrhythmic therapeutic.

  11. Sevoflurane causes less arrhythmias than desflurane after off-pump coronary artery bypass grafting: A pilot study

    Directory of Open Access Journals (Sweden)

    Hemmerling Thomas

    2010-01-01

    Full Text Available Background: Volatile anesthetics provide myocardial protection during cardiac surgery. Sevoflurane and desflurane are both efficient agents that allow immediate extubation after off-pump coronary artery bypass grafting (OPCABG. This study compared the incidence of arrhythmias after OPCABG with the two agents. Materials and Methods: Forty patients undergoing OPCABG with immediate extubation and perioperative high thoracic analgesia were included in this controlled, double-blind study; anesthesia was either provided using 1 MAC of sevoflurane (SEVO-group or desflurane (DES-group. Monitoring of perioperative arrhythmias was provided by continuous monitoring of the EKG up to 72 hours after surgery, and routine EKG monitoring once every day, until time of discharge. Patient data, perioperative arrhythmias, and myocardial protection (troponin I, CK, CK-MB-ratio, and transesophageal echocardiography examinations were compared using t-test, Fisher′s exact test or two-way analysis of variance for repeated measurements; P < 0.05. Results: Patient data and surgery-related data were similar between the two groups; all the patients were successfully extubated immediately after surgery, with similar emergence times. Supraventricular tachycardia occurred only in the DES-group (5 of 20 patients, atrial fibrillation was significantly more frequent in the DES group versus SEVO-group, at five out of 20 versus one out of 20 patients, respectively. Myocardial protection was equally achieved in both groups. Discussion: Ultra-fast track anesthesia using sevoflurane seems more advantageous than desflurane for anesthesia, for OPCABG, as it is associated with significantly less atrial fibrillation or supraventricular arrhythmias after surgery.

  12. Detection of Life Threatening Ventricular Arrhythmia Using Digital Taylor Fourier Transform.

    Science.gov (United States)

    Tripathy, Rajesh K; Zamora-Mendez, Alejandro; de la O Serna, José A; Paternina, Mario R Arrieta; Arrieta, Juan G; Naik, Ganesh R

    2018-01-01

    Accurate detection and classification of life-threatening ventricular arrhythmia episodes such as ventricular fibrillation (VF) and rapid ventricular tachycardia (VT) from electrocardiogram (ECG) is a challenging problem for patient monitoring and defibrillation therapy. This paper introduces a novel method for detection and classification of life-threatening ventricular arrhythmia episodes. The ECG signal is decomposed into various oscillatory modes using digital Taylor-Fourier transform (DTFT). The magnitude feature and a novel phase feature namely the phase difference (PD) are evaluated from the mode Taylor-Fourier coefficients of ECG signal. The least square support vector machine (LS-SVM) classifier with linear and radial basis function (RBF) kernels is employed for detection and classification of VT vs. VF, non-shock vs. shock and VF vs. non-VF arrhythmia episodes. The accuracy, sensitivity, and specificity values obtained using the proposed method are 89.81, 86.38, and 93.97%, respectively for the classification of Non-VF and VF episodes. Comparison with the performance of the state-of-the-art features demonstrate the advantages of the proposition.

  13. Arrhythmia as a cardiac manifestation in MELAS syndrome.

    Science.gov (United States)

    Thomas, Tamara; Craigen, William J; Moore, Ryan; Czosek, Richard; Jefferies, John L

    2015-09-01

    A 44-year-old female with a diagnosis of mitochondrial myopathy, encephalopathy and stroke-like episodes (MELAS) syndrome had progressive left ventricular hypertrophy (LVH) on echocardiogram. A Holter monitor demonstrated episodes of non-sustained atrial tachycardia, a finding not been previously described in this population. This unique case of MELAS syndrome demonstrates the known associated cardiac manifestation of LVH and the new finding of atrial tachycardia which may represent the potential for subclinical arrhythmia in this population.

  14. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  15. Adapting detection sensitivity based on evidence of irregular sinus arrhythmia to improve atrial fibrillation detection in insertable cardiac monitors.

    Science.gov (United States)

    Pürerfellner, Helmut; Sanders, Prashanthan; Sarkar, Shantanu; Reisfeld, Erin; Reiland, Jerry; Koehler, Jodi; Pokushalov, Evgeny; Urban, Luboš; Dekker, Lukas R C

    2017-10-03

    Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  16. New theory of arrhythmia. Conceptual substantiation of arrhythmia mechanisms

    Directory of Open Access Journals (Sweden)

    Vladimir I. Ermoshkin

    2015-11-01

    Full Text Available Aims A new attempt is made to substantiate the concept of the mechanism of arrhythmia and sudden cardiac death. Methods The paper is based on a theoretical analysis of special literature, personal experience of participation in conferences and discussions with leading Russian cardiologists. Results We have succeeded in demonstrating the fact that researchers ignore the fact that cardiomyocytes can be excited by mechanical pulses, when considering the arrhythmia mechanisms. We have conducted trials using the Cardiocode device. Under stress in a human, opened may be large and small arteriovenous anastomoses, via which blood under high pressure is ejected into veins. It leads to pressure surges in arteries and veins. The vena cava dilates, its tonus increases. In some cases, the pulse waves travel via anastomoses along the vena cava walls to the atria and the ventricles. An above-threshold concentration of tensions from mechanical pulses may excite cardiomyocytes from different points of the myocardium, disturbing the sinus rhythm. As a result, extrasystoles, tachycardia attacks, blocking of blood circulation in the peripheral segments of the venous arterial networks, edemata, thrombosis and metabolism disorders appear. Arrhythmia, tachycardia attacks and concomitant myocardial ischemia lead to progression of heart fibrosis. Such changes increase the probability of fibrillations and sudden cardiac death. Conclusion Unhealthy lifestyle, the presence of opening and not properly closing anastomoses may provoke a number of diseases. To avoid the cardiac arrhythmia attacks and prevent SCD, it is necessary to suppress travel of the mechanical waves within the following circuitry: aorta – artery – anastomosis – vein – vena cava – atria – ventricles. The travel of the mechanical waves within the same vessel circuitry explains the fact that the fixed couplings under extrasystoles are observed, and the beat-to-beat RR intervals under tachycardia

  17. Inhibition of Rac1 reduces store overload-induced calcium release and protects against ventricular arrhythmia.

    Science.gov (United States)

    Zhang, Lili; Lu, Xiangru; Gui, Le; Wu, Yan; Sims, Stephen M; Wang, Guoping; Feng, Qingping

    2016-08-01

    Rac1 is a small GTPase and plays key roles in multiple cellular processes including the production of reactive oxygen species (ROS). However, whether Rac1 activation during myocardial ischaemia and reperfusion (I/R) contributes to arrhythmogenesis is not fully understood. We aimed to study the effects of Rac1 inhibition on store overload-induced Ca(2+) release (SOICR) and ventricular arrhythmia during myocardial I/R. Adult Rac1(f/f) and cardiac-specific Rac1 knockdown (Rac1(ckd) ) mice were subjected to myocardial I/R and their electrocardiograms (ECGs) were monitored for ventricular arrhythmia. Myocardial Rac1 activity was increased and ventricular arrhythmia was induced during I/R in Rac1(f/f) mice. Remarkably, I/R-induced ventricular arrhythmia was significantly decreased in Rac1(ckd) compared to Rac1(f/f) mice. Furthermore, treatment with Rac1 inhibitor NSC23766 decreased I/R-induced ventricular arrhythmia. Ca(2+) imaging analysis showed that in response to a 6 mM external Ca(2+) concentration challenge, SOICR was induced with characteristic spontaneous intracellular Ca(2+) waves in Rac1(f/f) cardiomyocytes. Notably, SOICR was diminished by pharmacological and genetic inhibition of Rac1 in adult cardiomyocytes. Moreover, I/R-induced ROS production and ryanodine receptor 2 (RyR2) oxidation were significantly inhibited in the myocardium of Rac1(ckd) mice. We conclude that Rac1 activation induces ventricular arrhythmia during myocardial I/R. Inhibition of Rac1 suppresses SOICR and protects against ventricular arrhythmia. Blockade of Rac1 activation may represent a new paradigm for the treatment of cardiac arrhythmia in ischaemic heart disease. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  18. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    Science.gov (United States)

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  19. Alcohol, cardiac arrhythmias and sudden death.

    Science.gov (United States)

    Kupari, M; Koskinen, P

    1998-01-01

    Studies in experimental animals have shown varying and apparently opposite effects of alcohol on cardiac rhythm and conduction. Given acutely to non-alcoholic animals, ethanol may even have anti-arrhythmic properties whereas chronic administration clearly increases the animals' susceptibility to cardiac arrhythmias. Chronic heavy alcohol use has been incriminated in the genesis of cardiac arrhythmias in humans. The evidence has come from clinical observations, retrospective case-control studies, controlled studies of consecutive admissions for arrhythmias, and prospective epidemiological investigations. Furthermore, electrophysiological studies have shown that acute alcohol administration facilitates the induction of tachyarrhythmias in selected heavy drinkers. The role of alcohol appears particularly conspicuous in idiopathic atrial fibrillation. Occasionally, ventricular tachyarrhythmias have also been provoked by alcohol intake. Several lines of evidence suggest that heavy drinking increases the risk of sudden cardiac death with fatal arrhythmia as the most likely mechanism. According to epidemiological studies this effect appears most prominent in middle-aged men and is only partly explained by confounding traits such as smoking and social class. The basic arrhythmogenic effects of alcohol are still insufficiently delineated. Subclinical heart muscle injury from chronic heavy use may be instrumental in producing patchy delays in conduction. The hyperadrenergic state of drinking and withdrawal may also contribute, as may electrolyte abnormalities, impaired vagal heart rate control, repolarization abnormalities with prolonged QT intervals and worsening of myocardial ischaemia or sleep apnoea. Most of what we know about alcohol and arrhythmias relates to heavy drinking. The effect of social drinking on clinical arrhythmias in non-alcoholic cardiac patients needs to be addressed further.

  20. Arrhythmia and exercise intolerance in Fontan patients

    DEFF Research Database (Denmark)

    Idorn, L; Juul, K; Jensen, A S

    2013-01-01

    BACKGROUND: Long-term survival after the Fontan procedure shows excellent results but is associated with a persistent risk of arrhythmias and exercise intolerance. We aimed to analyze the current burden of clinically relevant arrhythmia and severe exercise intolerance in Danish Fontan patients...... and estimated to 99.1% per year. Prevalence of clinically relevant arrhythmia and severe exercise intolerance increased significantly with age and was found in 32% and 85% of patients ≥20years, respectively. Thus, from survival data and logistic regression models the future prevalence of patients, clinically...... relevant arrhythmia and severe exercise intolerance were estimated, revealing a considerable augmentation. Furthermore, resting and maximum cardiac index, resting stroke volume index and pulmonary diffusing capacity decreased significantly with age while diastolic and systolic ventricular function...

  1. Burden of arrhythmia in recreational marijuana users.

    Science.gov (United States)

    Desai, Rupak; Patel, Upenkumar; Deshmukh, Abhishek; Sachdeva, Rajesh; Kumar, Gautam

    2018-03-27

    Marijuana or Cannabis is extensively used as a recreational substance globally. Case reports have reported cardiac arrhythmias immediately following recreational marijuana use. However, the burden of arrhythmias in hospitalized marijuana users have not been evaluated through prospective or cross-sectional studies. Therefore, we planned to measure temporal trends of the frequency of arrhythmias in hospitalized marijuana users using National Inpatient Sample (NIS) database in the United States. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The association of air temperature with cardiac arrhythmias

    Science.gov (United States)

    Čulić, Viktor

    2017-11-01

    The body response to meteorological influences may activate pathophysiological mechanisms facilitating the occurrence of cardiac arrhythmias in susceptible patients. Putative underlying mechanisms include changes in systemic vascular resistance and blood pressure, as well as a network of proinflammatory and procoagulant processes. Such a chain reaction probably occurs within the time window of several hours, so use of daily average values of meteorological elements do not seem appropriate for investigation in this area. In addition, overall synoptic situation, and season-specific combinations of meteorological elements and air pollutant levels probably cause the overall effect rather than a single atmospheric element. Particularly strong interrelations have been described among wind speed, air pressure and temperature, relative air humidity, and suspended particulate matter. This may be the main reason why studies examining the association between temperature and ventricular arrhythmias have found linear positive, negative, J-shaped or no association. Further understanding of the pathophysiological adaptation to atmospheric environment may help in providing recommendations for protective measures during "bad" weather conditions in patients with cardiac arrhythmias.

  3. Wireless physiological monitoring system for psychiatric patients.

    Science.gov (United States)

    Rademeyer, A J; Blanckenberg, M M; Scheffer, C

    2009-01-01

    Patients in psychiatric hospitals that are sedated or secluded are at risk of death or injury if they are not continuously monitored. Some psychiatric patients are restless and aggressive, and hence the monitoring device should be robust and must transmit the data wirelessly. Two devices, a glove that measures oxygen saturation and a dorsally-mounted device that measures heart rate, skin temperature and respiratory rate were designed and tested. Both devices connect to one central monitoring station using two separate Bluetooth connections, ensuring a completely wireless setup. A Matlab graphical user interface (GUI) was developed for signal processing and monitoring of the vital signs of the psychiatric patient. Detection algorithms were implemented to detect ECG arrhythmias such as premature ventricular contraction and atrial fibrillation. The prototypes were manufactured and tested in a laboratory setting on healthy volunteers.

  4. Effect of low oral doses of disopyramide and amiodarone on ventricular and atrial arrhythmias of chagasic patients with advanced myocardial damage.

    Science.gov (United States)

    Carrasco, H A; Vicuña, A V; Molina, C; Landaeta, A; Reynosa, J; Vicuña, N; Fuenmayor, A; López, F

    1985-12-01

    Low-dose (7 mg/kg per day) disopyramide administration to arrhythmic chagasic patients decreased the frequency of ventricular extrasystoles in 4 of 17 patients (24%) and suppressed most complex ventricular arrhythmias in 12 of 15 patients (80%). This assessment was made from 72-h continuous Holter monitoring recorded during the course of this double blind, placebo-controlled randomized crossover study. Seven patients (41%) complained of anticholinergic side effects, but no contractile or conduction system depression was seen. Amiodarone (200 mg) given on a single blind, placebo-controlled basis to 9 of these patients reduced the frequency of ventricular extrasystoles in 6 of 9 patients (67%) and suppressed complex ventricular ectopy in 6 of 7 patients (85%). One patient was unable to tolerate this drug (11%). Both drugs seemed less effective in controlling supraventricular arrhythmias, although disopyramide eliminated paroxysms of supraventricular tachycardia in 9 of 13 (69%) and amiodarone in all 6 patients with this arrhythmia. Amiodarone appears to be a better antiarrhythmic drug for chagasic patients, due to its greater effectiveness and lower incidence of side effects.

  5. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  6. Cardiac arrhythmia as initial presentation of aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    van der Kleij, FGH; Henselmans, JML; van de Loosdrecht, AA

    1999-01-01

    Cardiac arrhythmia and sudden death are most frequently caused by preexisting heart disease. Rarely, cardiac arrhythmia is a first symptom of an acute neurological event. We describe a patient with asystole and other cardiac arrhythmias, as initial symptoms of acute aneurysmal subarachnoid

  7. A CAMAC system for cardiologic monitoring

    International Nuclear Information System (INIS)

    Ouali, Abderrazak

    1977-01-01

    Standard CAMAC rules and features are summarized and a configuration is described for E.C.G. monitoring in intensive care units. This configuration contains intelligent modules (including microprocessors) for the biomedical signals pre-processing and for the CAMAC control. One of these modules analyses in real time the arrythmias from two different E.C.G. channels. With micro-programmed algorithms each arrhythmia is counted and stored in numerical files which are transmitted via the CAMAC data-way to an autonomous crate controller JCAM-10 linked to an interactive graphic and alphanumeric display unit. (author) [fr

  8. Electrocardiographic Patch Devices and Contemporary Wireless Cardiac Monitoring

    Directory of Open Access Journals (Sweden)

    Erik eFung

    2015-05-01

    Full Text Available Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG, Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable ‘on-body’ ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.

  9. Malignant Arrhythmia in Apical Ballooning Syndrome: Risk Factors and Outcomes

    Directory of Open Access Journals (Sweden)

    Samuel J. Asirvatham

    2008-08-01

    Full Text Available Objectives: We sought to determine the frequency and outcomes with symptomatic arrhythmia in patients with apical ballooning syndrome (ABS. Methods: A retrospective review of the Mayo Clinic Angiography database was conducted to identify patients who met the Mayo criteria for ABS. Patients with documented arrhythmias formed the study group, and 31 randomly selected patients with ABS but without arrhythmia formed the control group.Results: Out of 105 patients identified with ABS, 6 (5.7% women aged 69 +/- 9 years experienced significant arrhythmia (ventricular fibrillation, asystole, 2 patients died, and 1 required permanent pacemaker implantation. When compared with controls, the study group showed no significant difference with respect to ECG characteristics (QT, QRS duration or axis except for R-R interval variability (see comments below (30.6±6 vs 14.5±17 p = 0.0004, QTc, and P-R interval. Patients without arrhythmia were more likely to be on beta-blocker therapy than the study population (33% vs 80.6% p = 0.02. Conclusion: Life-threatening arrhythmia is uncommon (5.7% with ABS despite marked, structural abnormalities. When arrhythmias do occur, the outcome is poor. Prominent variability in R-R intervals appears to be predictive of significant arrhythmias in ABS. The role of beta-blocker therapy in preventing arrhythmia with ABS requires further investigation.

  10. [The design of a cardiac monitoring and analysing system with low power consumption].

    Science.gov (United States)

    Chen, Zhen-cheng; Ni, Li-li; Zhu, Yan-gao; Wang, Hong-yan; Ma, Yan

    2002-07-01

    The paper deals with a portable analyzing monitor system with liquid crystal display (LCD), which is low in power consumption and suitable for China's specific conditions. Apart from the development of the overall scheme of the system, the paper introduces the design of the hardware and the software. The 80196 single chip microcomputer is used as the central microprocessor to process and real-time electrocardiac signal data. The system have the following functions: five types of arrhythmia analysis, alarm, freeze, and record of automatic paperfeeding. The portable system can be operated by alternate-current (AC) or direct-current (DC). Its hardware circuit is simplified and its software structure is optimized. Multiple low power consumption and LCD unit are adopted in its modular designs.

  11. Spiral Wave Initiation in Reaction-Diffusion-Mechanics Systems: A Model for the Onset of Reentrant Cardiac Arrhythmia

    NARCIS (Netherlands)

    Weise, L.D.

    2012-01-01

    Heart failure due to cardiac arrhythmias is a major cause of death in the industrialized world. Cardiac arrhythmia is often caused by spi- ral waves of electrical activity in the cardiac muscle. Therefore, it is a major task in cardiology to understand the mechanisms of spiral wave initiation in the

  12. Cardiac arrhythmias in adult patients with asthma

    DEFF Research Database (Denmark)

    Warnier, Miriam J; Rutten, Frans H; Kors, Jan A

    2012-01-01

    OBJECTIVE: The pathogenesis of cardiac arrhythmias in asthma patients has not been fully elucidated. Adverse drug effects, particularly those of β2-mimetics, may play a role. The aim of this study was to determine whether asthma is associated with the risk of cardiac arrhythmias and electrocardio......OBJECTIVE: The pathogenesis of cardiac arrhythmias in asthma patients has not been fully elucidated. Adverse drug effects, particularly those of β2-mimetics, may play a role. The aim of this study was to determine whether asthma is associated with the risk of cardiac arrhythmias...... and electrocardiographic characteristics of arrhythmogenicity (ECG) and to explore the role of β2-mimetics. METHODS: A cross-sectional study was conducted among 158 adult patients with a diagnosis of asthma and 6303 participants without asthma from the cohort of the Utrecht Health Project-an ongoing, longitudinal, primary...... or flutter). Secondary outcomes were tachycardia, bradycardia, PVC, atrial fibrillation or flutter, mean heart rate, mean corrected QT (QTc) interval length, and prolonged QTc interval. RESULTS: Tachycardia and PVCs were more prevalent in patients with asthma (3% and 4%, respectively) than those without...

  13. Ventricular arrhythmia burst is an independent indicator of larger infarct size even in optimal reperfusion in STEMI

    NARCIS (Netherlands)

    van der Weg, Kirian; Majidi, Mohamed; Haeck, Joost D. E.; Tijssen, Jan G. P.; Green, Cynthia L.; Koch, Karel T.; Kuijt, Wichert J.; Krucoff, Mitchell W.; Gorgels, Anton P. M.; de Winter, Robbert J.

    2016-01-01

    We hypothesized that ventricular arrhythmia (VA) bursts during reperfusion phase are a marker of larger infarct size despite optimal epicardial and microvascular perfusion. 126 STEMI patients were studied with 24h continuous, 12-lead Holter monitoring. Myocardial blush grade (MBG) was determined and

  14. Electrical Signs predictors of malignant ventricular arrhythmias

    International Nuclear Information System (INIS)

    Aleman Fernandez, Ailema Amelia; Dorantes Sanchez, Margarita

    2012-01-01

    Recurrence of malignant ventricular arrhythmia is frequent in cardioverter-defibrillators related patients. The risk stratification is difficult, there are numerous electrocardiographic predictors but his sensibility and specificity are not absolute. The limit between normal and pathological is not defined, besides the complexity of ventricular arrhythmias. We expose different electrocardiographic predictors that can help to better individual risk stratification

  15. [Idiopathic ventricular arrhythmia in children. Apropos of 24 cases].

    Science.gov (United States)

    Coeurderoy, A; Almange, C; Laurent, M; Biron, Y; Leborgne, P

    1985-12-01

    The severity and prognosis of idiopathic ventricular arrhythmias in childhood were studied in 24 patients (12 boys, 12 girls) with an average age of 8 years at the time of diagnosis of the arrhythmia. Investigations included clinical assessment and analysis of basal ECG (morphology of the arrhythmias) and dynamic recordings (Holter and exercise stress testing). The clinical course was followed for an average of 3.8 years. The patients were classified in two groups: monomorphic arrhythmias (Group I) and polymorphic arrhythmias (Group II). Group I was divided into 4 subgroups: isolated ventricular extrasystoles (IA), 11 patients; ventricular extrasystoles with bursts of ventricular tachycardia (IB), 6 patients; sustained ventricular tachycardia without intercritical extrasystoles (IC), 1 patient; accelerated idioventricular rhythm (ID), 2 patients. Subgroups IA, IB and ID were characterised by the absence of symptoms, the disappearance of the arrhythmia on exercise, the decreased efficacy of antiarrhythmic drugs and an excellent prognosis. Therapeutic abstention was the rule in these patients. Patients in Group IC were characterised by the variability of their symptoms, the absence of exercise induced arrhythmias, the need for treatment in most cases and a good long-term prognosis. Group II was divided into 2 subgroups: adrenergic polymorphic ventricular tachycardia (IIA), 2 patients, and non-adrenergic polymorphic ventricular tachycardia (IIB), 2 patients. Patients in Subgroup IIA were characterised by syncope on exercise or emotion, the need for betablocker therapy which considerably improved the patients symptoms but which did not usually prevent sudden death.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  17. QTc-prolonging drugs and hospitalizations for cardiac arrhythmias

    NARCIS (Netherlands)

    De Bruin, ML; Hoes, AW; Leufkens, HGM

    2003-01-01

    Cardiac arrhythmia as an adverse effect of noncardiac drugs has been an issue of growing importance during the past few years. In this population-based study, we evaluated the risk for serious cardiac arrhythmias during the use of several noncardiac QTc-prolonging drugs in day-to-day practice, and

  18. Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system

    Directory of Open Access Journals (Sweden)

    Diego Vanegas-Cadavid

    2018-05-01

    Full Text Available Objectives: To present the clinical experience with a new extended (for 15 days, wireless, and satellite cardiac monitoring system in a group of patients with suspicion of cardiac arrhythmia. Method: The study included a cohort of 100 patients seen in the Cardiovascular Electrophysiology Unit of a reference hospital. They were suspected of having a cardiac arrhythmia, with no electrocardiographic diagnosis of the cause, despite previous examinations. They were subjected to SEEQ-type (Medtronic external cardiac monitoring for 15 days, with the outcomes recorded. Results: Of the total of 100 subjects studied, 51% were male, and the median age was 60 years (range: 5 - 91 years. The main symptoms were palpitation, and the most prevalent comorbidity was arterial hypertension (47%. Almost all (98% of them had a previous Holter study, and 46% had two studies, which were inconclusive in explaining the symptoms. The SEEQ monitoring recorded a significant electrocardiographic abnormality in 22% of the patients. A pacemaker implant was the treatment most applied and atrial fibrillation was the most frequent arrhythmia in 50% of the positive findings. There was a higher and significant percentage of positive diagnoses in males. Conclusions: External, satellite, wireless cardiac monitoring extended for 15 days, is a novel tool that can increase the probability of documenting a clinically significant electrocardiographic abnormality in those patients who suffer recurrent cardiovascular symptoms. Resumen: Objetivos: Dar a conocer la experiencia clínica con un nuevo sistema de monitorización cardiaca extendida (por 15 días, inalámbrica y satelital en un grupo de pacientes con sospecha de arritmias cardíacas. Metodología: Cohorte de 100 pacientes atendidos en la unidad de Electrofisiología cardiovascular de un centro de referencia, con sospecha de arritmia cardíaca, sin diagnóstico electrocardiográfico causal, a pesar de exámenes previos. Se les aplic

  19. Atrial Arrhythmias in Astronauts. Summary of a NASA Summit

    Science.gov (United States)

    Barr, Yael; Watkins, Sharmila; Polk, J. D.

    2011-01-01

    This slide presentation reviews the findings of a panel of heart experts brought together to study if atrial arrhythmias more prevalent in astronauts, and potential risk factors that may predispose astronauts to atrial arrhythmias. The objective of the panel was to solicit expert opinion on screening, diagnosis, and treatment options, identify gaps in knowledge, and propose relevant research initiatives. While Atrial Arrhythmias occur in approximately the same percents in astronauts as in the general population, they seem to occur at younger ages in astronauts. Several reasons for this predisposition were given: gender, hypertension, endurance training, and triggering events. Potential Space Flight-Related Risk factors that may play a role in precipitating lone atrial fibrillation were reviewed. There appears to be no evidence that any variable of the space flight environment increases the likelihood of developing atrial arrhythmias during space flight.

  20. Percutaneous autonomic neural modulation: A novel technique to treat cardiac arrhythmia

    International Nuclear Information System (INIS)

    DeSimone, Christopher V.; Madhavan, Malini; Venkatachalam, Kalpathi L.; Knudson, Mark B.; Asirvatham, Samuel J.

    2013-01-01

    Ablation and anti-arrhythmic medications have shown promise but have been met with varying success and unwanted side effects such as myocardial injury, arrhythmias, and morbidity from invasive surgical intervention. The answer to improving efficacy of ablation may include modulation of the cardiac aspect of the autonomic nervous system. Our lab has developed a novel approach and device to navigate the oblique sinus and to use DC current and saline/alcohol irrigation to selectively stimulate and block the autonomic ganglia found on the epicardial side of the heart. This novel approach minimizes myocardial damage from thermal injury and provides a less invasive and targeted approach. For feasibility, proof-of-concept, and safety monitoring, we carried out canine studies to test this novel application. Our results suggest a safer and less invasive way of modulating arrhythmogenic substrate that may lead to improved treatment of AF in humans

  1. Percutaneous autonomic neural modulation: A novel technique to treat cardiac arrhythmia

    Energy Technology Data Exchange (ETDEWEB)

    DeSimone, Christopher V.; Madhavan, Malini [Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN (United States); Venkatachalam, Kalpathi L. [Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Jacksonville, FL (United States); Knudson, Mark B. [Mayo Clinic, Rochester, MN (United States); EnteroMedics, EnteroMedics, St. Paul, MN (United States); Asirvatham, Samuel J., E-mail: asirvatham.samuel@mayo.edu [Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN (United States); Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Mayo Clinic, Rochester, MN (United States)

    2013-05-15

    Ablation and anti-arrhythmic medications have shown promise but have been met with varying success and unwanted side effects such as myocardial injury, arrhythmias, and morbidity from invasive surgical intervention. The answer to improving efficacy of ablation may include modulation of the cardiac aspect of the autonomic nervous system. Our lab has developed a novel approach and device to navigate the oblique sinus and to use DC current and saline/alcohol irrigation to selectively stimulate and block the autonomic ganglia found on the epicardial side of the heart. This novel approach minimizes myocardial damage from thermal injury and provides a less invasive and targeted approach. For feasibility, proof-of-concept, and safety monitoring, we carried out canine studies to test this novel application. Our results suggest a safer and less invasive way of modulating arrhythmogenic substrate that may lead to improved treatment of AF in humans.

  2. From Incidental, Mechanically-Induced Arrhythmias to Reflex-Defined Arrhythmogenicity: On The Track of The Ternary Reflex System Resemblance to The "Infancy" of New Era or Rediscovery.

    Science.gov (United States)

    Stirbys, Petras

    2016-01-01

    The underlying pathophysiology of supraventricular and ventricular arrhythmias remains a matter of intense investigation. Though evolving, the contemporary explanations do not encompass all aspects of arrhythmogenicity. An improved understanding of arrhythmia substrate is needed to augment therapeutic capabilities. Our observation and literature sources demonstrate relatively high incidence of transitory arrhythmias which are non-intentionally generated by the endocardial lead/catheter manipulation. These findings are interesting and potentially may crystallize the reflex-dependent proarrhythmic cardiac activity. Herein we suggest the "reflexogenic arrhythmogenicity" concept extending an overall spectrum of known hypotheses. Cardiovascular reflex action can be categorized into three-tiered levels - intra-cellular, inter-cellular and inter-organic. The first two levels of the triplicate system reside within the cardiac anatomical landmarks (in fact intramurally, intra-organically), however the third one implicates central (cerebral) activity which boomerangs back via centripetal and centrifugal connections. These levels likely compose synoptic ternary reflex set system which may be validated in future studies. To hypothesize, coordinated mutual reciprocity of reflex activity results in stabilization of heart rhythm in robust heart. Any stressful cardiac event may lead to the shift of the rhythm toward unfavorable clinical entity probably via the loss of the influence of dominant reflex. Overall, an interaction and likely intrinsic inter-tiered competition along with possible interplay between physiological and pathological reflexes may be treated as contributing factors for the inception and maintaining of arrhythmias and cardiac performance as well. These assumptions await further documentation. If such a tenet were recognized, the changes in the clinical approach to arrhythmia management might be anticipated, preferably by selective reflex suppression or

  3. Channelopathies - emerging trends in the management of inherited arrhythmias

    NARCIS (Netherlands)

    Chockalingam, Priya; Mizusawa, Yuka; Wilde, Arthur A. M.

    2015-01-01

    In spite of their relative rarity, inheritable arrhythmias have come to the forefront as a group of potentially fatal but preventable cause of sudden cardiac death in children and (young) adults. Comprehensive management of inherited arrhythmias includes diagnosing and treating the proband and

  4. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  5. Arrhythmia phenotype in mouse models of human long QT.

    Science.gov (United States)

    Salama, Guy; Baker, Linda; Wolk, Robert; Barhanin, Jacques; London, Barry

    2009-03-01

    Enhanced dispersion of repolarization (DR) was proposed as a unifying mechanism, central to arrhythmia genesis in the long QT (LQT) syndrome. In mammalian hearts, K(+) channels are heterogeneously expressed across the ventricles resulting in 'intrinsic' DR that may worsen in long QT. DR was shown to be central to the arrhythmia phenotype of transgenic mice with LQT caused by loss of function of the dominant mouse K(+) currents. Here, we investigated the arrhythmia phenotype of mice with targeted deletions of KCNE1 and KCNH2 genes which encode for minK/IsK and Merg1 (mouse homolog of human ERG) proteins resulting in loss of function of I(Ks) and I(Kr), respectively. Both currents are important human K(+) currents associated with LQT5 and LQT2. Loss of minK, a protein subunit that interacts with KvLQT1, results in a marked reduction of I(Ks) giving rise to the Jervell and Lange-Nielsen syndrome and the reduced KCNH2 gene reduces MERG and I(Kr). Hearts were perfused, stained with di-4-ANEPPS and optically mapped to compare action potential durations (APDs) and arrhythmia phenotype in homozygous minK (minK(-/-)) and heterozygous Merg1 (Merg(+/-)) deletions and littermate control mice. MinK(-/-) mice has similar APDs and no arrhythmias (n = 4). Merg(+/-) mice had prolonged APDs (from 20 +/- 6 to 32 +/- 9 ms at the base, p mice (60% vs. 10%). A comparison of mouse models of LQT based on K(+) channel mutations important to human and mouse repolarization emphasizes DR as a major determinant of arrhythmia vulnerability.

  6. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology.

    Science.gov (United States)

    Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M B

    2015-01-01

    This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet.

  7. Loperamide Induced Life Threatening Ventricular Arrhythmia

    Directory of Open Access Journals (Sweden)

    Ankit Upadhyay

    2016-01-01

    Full Text Available Loperamide is over-the-counter antidiarrheal agent acting on peripherally located μ opioid receptors. It is gaining popularity among drug abusers as opioid substitute. We report a case of a 46-year-old male that was presented after cardiac arrest. After ruling out ischemia, cardiomyopathy, pulmonary embolism, central nervous system pathology, sepsis, and other drug toxicity, we found out that patient was using around 100 mg of Loperamide to control his chronic diarrhea presumably because of irritable bowel syndrome for last five years and consumed up to 200 mg of Loperamide daily for last two days before the cardiac arrest. We hypothesize that the patient’s QTc prolongation and subsequent cardiac arrest are due to Loperamide toxicity. Patient experienced gradual resolution of tachyarrhythmia and gradual decrease in QTc interval during hospitalization which supports the evidence of causal relationship between Loperamide overdose and potentially fatal arrhythmias. It also provided the clue that patient may have congenital long QT syndrome which was unmasked by Loperamide causing ventricular arrhythmias. This case adds one more pearl in the literature to support that Loperamide overdose related cardiac toxicity does exist and it raises concerns over Loperamide abuse in the community.

  8. [Analysis of the heart sound with arrhythmia based on nonlinear chaos theory].

    Science.gov (United States)

    Ding, Xiaorong; Guo, Xingming; Zhong, Lisha; Xiao, Shouzhong

    2012-10-01

    In this paper, a new method based on the nonlinear chaos theory was proposed to study the arrhythmia with the combination of the correlation dimension and largest Lyapunov exponent, through computing and analyzing these two parameters of 30 cases normal heart sound and 30 cases with arrhythmia. The results showed that the two parameters of the heart sounds with arrhythmia were higher than those with the normal, and there was significant difference between these two kinds of heart sounds. That is probably due to the irregularity of the arrhythmia which causes the decrease of predictability, and it's more complex than the normal heart sound. Therefore, the correlation dimension and the largest Lyapunov exponent can be used to analyze the arrhythmia and for its feature extraction.

  9. Effect of acute alloxan diabetes on ischemic and reperfusion arrhythmias in rats with different activity of nitric oxide system.

    Science.gov (United States)

    Belkina, L M; Terekhina, O L; Smirnova, E A; Usacheva, M A; Kruglov, S V; Saltykova, V A

    2011-01-01

    Similar degree of glycemia (28-31 mmol/liter) and similar mortality (37-42%) were revealed in August rats exhibiting enhanced activity of NO system and in Wistar rats 3 weeks after alloxan treatment. Under conditions of myocardial ischemia caused by 10-min coronary artery ligation, the intensity of arrhythmias did not differ from the control in Wistar rats with diabetes mellitus and increased in August rats. Under conditions of reperfusion, diabetes produced an antiarrhythmic effect in Wistar rats and did not affect arrhythmia in August rats. Plasma concentrations of nitrates and nitrites in Wistar and August rats increased by 82 and 143%, respectively, compared to the control. The level of hemoxygenase-1 (hsp32) in the myocardium remained unchanged in Wistar rats and decreased by 26% in August rats. Thus, the absence of antiarrhythmic effect of acute diabetes in August rats is probably related to elevated NO content and reduced antioxidant activity.

  10. Dobutamine use for arrhythmia induction during electrical programmed heart stimulation

    International Nuclear Information System (INIS)

    Vanegas, Diego I; Perez, Climaco de J; Montenegro, Juan de J; Orjuela, Alejandro

    2006-01-01

    isoproterenol is the traditionally used drug for incrementing arrhythmia induction when this induction is not achieved during electric programmed heart stimulation under basal conditions. Dobutamine is an adrenergic agent, chemical precursor of isoproterenol, which can be an alternative for inducing arrhythmia during electrical programmed heart stimulation (PES). Patients and methods: a retrospective comparative study of the experience with dobutamine for inducing arrhythmia during electrical programmed heart stimulation was performed. The following data were collected: number of studies, data about the patient (medical record, age, gender, and study indication) protocol of programmed electrical stimulation, basal and under dobutamine or isoproterenol, and result of the study. Isoproterenol was used in doses of 1 to 3 micrograms per minute until the basal heart rate was incremented at least in 25%. Dobutamine was used in doses of 10 to 40 micrograms per kg of body weight, until obtaining the same increment in the basal heart rate. Results: 1054 electrophysiological studies were evaluated. In 144 patients (group A) isoproterenol was used and in 140, dobutamine (group B). In A group the mean age was 39.2 ± 16.2 and 58.3% were females. In-group B, mean age was 41.9 ± 18.6 and 51% were females. The most frequent symptom was palpitation and the most commonly induced arrhythmia was AV nodal reentry tachycardia in both groups. The induction of arrhythmia during the electrical programmed heat stimulation under drugs was similar in-group A (isoproterenol) respect to group B (dobutamine). Conclusions: There were no statistical significant differences in the induction of arrhythmia during electrical programmed heart stimulation using dobutamine or isoproterenol. Dobutamine may be safe and may be successfully used as an alternative to isoproterenol for arrhythmia induction during electrical programmed stimulation

  11. Increasing Prevalence of Atrial Fibrillation and Permanent Atrial Arrhythmias in Congenital Heart Disease.

    Science.gov (United States)

    Labombarda, Fabien; Hamilton, Robert; Shohoudi, Azadeh; Aboulhosn, Jamil; Broberg, Craig S; Chaix, Marie A; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Macle, Laurent; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Khairy, Paul

    2017-08-15

    Atrial arrhythmias are the most common complication encountered in the growing and aging population with congenital heart disease. This study sought to assess the types and patterns of atrial arrhythmias, associated factors, and age-related trends. A multicenter cohort study enrolled 482 patients with congenital heart disease and atrial arrhythmias, age 32.0 ± 18.0 years, 45.2% female, from 12 North American centers. Qualifying arrhythmias were classified by a blinded adjudicating committee. The most common presenting arrhythmia was intra-atrial re-entrant tachycardia (IART) (61.6%), followed by atrial fibrillation (28.8%), and focal atrial tachycardia (9.5%). The proportion of arrhythmias due to IART increased with congenital heart disease complexity from 47.2% to 62.1% to 67.0% in patients with simple, moderate, and complex defects, respectively (p = 0.0013). Atrial fibrillation increased with age to surpass IART as the most common arrhythmia in those ≥50 years of age (51.2% vs. 44.2%; p congenital heart disease, with a predominantly paroxysmal pattern. However, atrial fibrillation increases in prevalence and atrial arrhythmias progressively become permanent as the population ages. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Temporal abstraction and inductive logic programming for arrhythmia recognition from electrocardiograms.

    Science.gov (United States)

    Carrault, G; Cordier, M-O; Quiniou, R; Wang, F

    2003-07-01

    This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.

  13. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PRarrhythmias. Dual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to

  14. Symmetrical compression distance for arrhythmia discrimination in cloud-based big-data services.

    Science.gov (United States)

    Lillo-Castellano, J M; Mora-Jiménez, I; Santiago-Mozos, R; Chavarría-Asso, F; Cano-González, A; García-Alberola, A; Rojo-Álvarez, J L

    2015-07-01

    The current development of cloud computing is completely changing the paradigm of data knowledge extraction in huge databases. An example of this technology in the cardiac arrhythmia field is the SCOOP platform, a national-level scientific cloud-based big data service for implantable cardioverter defibrillators. In this scenario, we here propose a new methodology for automatic classification of intracardiac electrograms (EGMs) in a cloud computing system, designed for minimal signal preprocessing. A new compression-based similarity measure (CSM) is created for low computational burden, so-called weighted fast compression distance, which provides better performance when compared with other CSMs in the literature. Using simple machine learning techniques, a set of 6848 EGMs extracted from SCOOP platform were classified into seven cardiac arrhythmia classes and one noise class, reaching near to 90% accuracy when previous patient arrhythmia information was available and 63% otherwise, hence overcoming in all cases the classification provided by the majority class. Results show that this methodology can be used as a high-quality service of cloud computing, providing support to physicians for improving the knowledge on patient diagnosis.

  15. Types of Arrhythmia in Children

    Science.gov (United States)

    ... even though they may need to keep taking medicine. Your child will probably need periodic check-ups but will ... minute. Understand and manage medications Parents of a child taking medicine for an arrhythmia should give the medicine at ...

  16. Transcatheter radiofrequency ablation under the guidance of three-dimensional mapping for the treatment of complex cardiac arrhythmias

    International Nuclear Information System (INIS)

    Hong Lang; Wang Hong; Lai Hengli; Ying Qiulin; Chen Zhangqiang; Lu Linxiang; Qiu Yun; Xiao Chengwei

    2010-01-01

    Objective: To investigate the effectiveness and safety of transcatheter radiofrequency ablation guided by a three-dimensional mapping system (Ensite or Carto) for the treatment of complex cardiac arrhythmias. Methods: A cohort of 123 consecutive hospitalized inpatients during the period from February 2006 to December 2008 were selected for this study. These patients suffered from various arrhythmias, including paroxysmal atrial fibrillation (n = 58), persistent or permanent atrial fibrillation (n = 10), atrial flutter (n = 13), atrial tachycardia (n = 12) and ventricular tachycardia or frequent ventricular premature beats (n = 30). Transcatheter radiofrequency ablation for arrhythmias was performed under the guidance of an EnSite3000 / NavX or Array mapping system in 80 cases, and under the guidance of a CARTO mapping system in the remaining 43 cases. Results: Successful ablation of arrhythmias was obtained by single operation in 106 cases (86.18%), including 59 cases with atrial fibrillation, 11 cases with atrial flutter, 10 cases with atrial tachycardia, and 26 cases with ventricular tachycardia or premature ventricular beat.Ablation procedure was carried out and was successful in 10 cases with a successful rate of 94.31%, including 5 cases with atrial fibrillation, 1 case with recurred atrial flutter, 1 case with recurrent atrial tachycardia, and 3 cases with ventricular tachycardia or premature ventricular beat.After operation, complications occurred in 6 cases, including cardiac tamponade in 4 cases, distal embolism of the left anterior descending coronary artery in 1 case, and pulmonary embolism in 1 case. Conclusion: Three-dimensional mapping system can clearly and stereoscopically display the cardiac structures. Therefore, this technique is of great value in guiding the transcatheter radiofrequency ablation for complex arrhythmias, in improving the success rate of ablation and in increasing the safety of the procedure. (authors)

  17. Andrographolide inhibits arrhythmias and is cardioprotective in rabbits

    OpenAIRE

    Zeng, Mengliu; Jiang, Wanzhen; Tian, Youjia; Hao, Jie; Cao, Zhenzhen; Liu, Zhipei; Fu, Chen; Zhang, Peihua; Ma, Jihua

    2017-01-01

    Andrographolide has a protective effect on the cardiovascular system. To study its cardic-electrophysiological effects, action potentials and voltage-gated Na+ (INa), Ca2+ (ICaL), and K+ (IK1, IKr, Ito and IKur) currents were recorded using whole-cell patch clamp and current clamp techniques. Additionally, the effects of andrographolide on aconitine-induced arrhythmias were assessed on electrocardiograms in vivo. We found that andrographolide shortened action potential duration and reduced ma...

  18. FY1995 report on the remote monitoring system for the aged at home; 1995 nendo zaitaku koreisha no kenko jotai enkaku kanshi system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The purpose of the project is to develop a prototype system which monitors the health conditions of the aged living alone by measuring his/her electronic cardiograms at sleep and the activity of movement at daytime which are gathered by telephone lines. The practicability of the system is also verified. After our newly developed health monitoring system was applied for one year in four people over age 80, this system is useful to monitor both ECG during night and the daily activity at home of the aged living alone for long term without being aware. In each subject, a unique pattern of ECG waveform and the daily activity at home was found. Since the individual activity was fairly stable throughout the year, we were able to point out the unusual days by comparing the daily activity pattern with the reference pattern and analysis the reason. As to the clinical problem, we called one subject to come to see a doctor after we found temporary ventricular arrhythmia in his record. On the occasion of unusual activity, we called the subject and/or his/her neighbors and found a health problem. Depending on the response to the call, the system administrator took an appropriate action like informing the relatives or making a visit. (NEDO)

  19. A Proposal for Cardiac Arrhythmia Classification using Complexity Measures

    Directory of Open Access Journals (Sweden)

    AROTARITEI, D.

    2017-08-01

    Full Text Available Cardiovascular diseases are one of the major problems of humanity and therefore one of their component, arrhythmia detection and classification drawn an increased attention worldwide. The presence of randomness in discrete time series, like those arising in electrophysiology, is firmly connected with computational complexity measure. This connection can be used, for instance, in the analysis of RR-intervals of electrocardiographic (ECG signal, coded as binary string, to detect and classify arrhythmia. Our approach uses three algorithms (Lempel-Ziv, Sample Entropy and T-Code to compute the information complexity applied and a classification tree to detect 13 types of arrhythmia with encouraging results. To overcome the computational effort required for complexity calculus, a cloud computing solution with executable code deployment is also proposed.

  20. P wave detector with PP rhythm tracking: evaluation in different arrhythmia contexts

    International Nuclear Information System (INIS)

    Portet, François

    2008-01-01

    Automatic detection of atrial activity (P waves) in an electrocardiogram (ECG) is a crucial task to diagnose the presence of arrhythmias. The P wave is difficult to detect and most of the approaches in the literature have been evaluated on normal sinus rhythms and rarely considered arrhythmia contexts other than atrial flutter and fibrillation. A novel knowledge-based P wave detector algorithm is presented. It is self-adaptive to the patient and able to deal with certain arrhythmias by tracking the PP rhythm. The detector has been tested on 12 records of the MIT-BIH arrhythmia database containing several ventricular and supra-ventricular arrhythmias. On the overall records, the detector demonstrates Se = 96.60% and Pr = 95.46%; for the normal sinus rhythm, it reaches Se = 97.76% and Pr = 96.80% and, in the case of Mobitz type II, it demonstrates Se = 72.79% and Pr = 99.51%. It also shows good performance for trigeminy and bigeminy, and outperforms some more sophisticated techniques. Although the results emphasize the difficulty of P wave detection in difficult arrhythmias (supra and ventricular tachycardias), it shows that domain knowledge can efficiently support signal processing techniques

  1. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    Science.gov (United States)

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support

  2. Epidemiology of Arrhythmias in Children

    Directory of Open Access Journals (Sweden)

    R Prem Sekar

    2008-05-01

    Full Text Available Unlike the adult population, arrhythmias occur less commonly in childhood. Only 5% of the emergency hospital admissions in the paediatric population is attributed to symptomatic arrhythmias. Majority of these tend to be accessory pathway mediated supraventricular tachyarrhythmias such as Wolff-Parkinson-White (WPW syndrome, permanent junctional reciprocating tachycardia (PJRT and Mahaim tachycardia. The non accessory pathway mediated supraventricular tachyarrhythmias commonly seen in children are junctional ectopic tachycardia (JET and automatic ectopic atrial tachycardia (AET and occur mostly in the post operative period after intracardiac repair for a structural heart defect. Ventricular tachycardia (VT although uncommon, occurs in the paediatric age group in association with hypertrophic cardiomyopathy (HCM, long QT syndrome (LQTS and Brugada syndrome. Occasionally, VT can also present symptomatically as incessant idiopathic infant ventricular tachycardia, right ventricular outflow tract tachycardia, benign VT, catecholaminic VT, idiopathic left ventricular tachycardia and in post cardiac surgical patients.

  3. Disease and drug-induced arrhythmias : the example of obstructive pulmonary disease

    NARCIS (Netherlands)

    Warnier, M.J.

    2014-01-01

    Notwithstanding the clinical importance of cardiac arrhythmias, relevant information about the background risk and the exact underlying mechanisms of cardiac arrhythmias in patients with obstructive pulmonary disease (asthma and chronic obstructive pulmonary disease [COPD]) is still lacking. The

  4. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  5. Illicit drugs and cardiac arrhythmias in athletes.

    Science.gov (United States)

    Furlanello, Francesco; Serdoz, Laura Vitali; Cappato, Riccardo; De Ambroggi, Luigi

    2007-08-01

    The current management of athletes with cardiac arrhythmias has become complicated by the widespread use of illicit drugs, which can be arrhythmogenic. The World Anti-Doping Agency annually updates a list of prohibited substances and methods banned by the International Olympic Committee that includes different classes of substances namely, anabolic androgenic steroids, hormones and related substances, beta2-agonists, diuretics, stimulants, narcotics, cannabinoids, glucocorticosteroids, alcohol, beta-blockers and others. Almost all illicit drugs may cause, through a direct or indirect arrhythmogenic effect, a wide range of cardiac arrhythmias (focal or reentry type, supraventricular and/or ventricular) that can even be lethal and which are frequently sport activity related. A large use of illicit drugs has been documented in competitive athletes, but the arrhythmogenic effect of specific substances is not precisely known. Precipitation of cardiac arrhythmias, particularly in the presence of a latent electrophysiologic substrate including some inherited cardiomyopathies, at risk of sudden death or due to long-term consumption of the substances, should raise the suspicion that illicit drugs may be a possible cause and lead cardiologists to investigate carefully this relationship and appropriately prevent the clinical consequences.

  6. Gene Therapy in Cardiac Arrhythmias

    Directory of Open Access Journals (Sweden)

    Praveen S.V

    2006-04-01

    Full Text Available Gene therapy has progressed from a dream to a bedside reality in quite a few human diseases. From its first application in adenosine deaminase deficiency, through the years, its application has evolved to vascular angiogenesis and cardiac arrhythmias. Gene based biological pacemakers using viral vectors or mesenchymal cells tested in animal models hold much promise. Induction of pacemaker activity within the left bundle branch can provide stable heart rates. Genetic modification of the AV node mimicking beta blockade can be therapeutic in the management of atrial fibrillation. G protein overexpression to modify the AV node also is experimental. Modification and expression of potassium channel genes altering the delayed rectifier potassium currents may permit better management of congenital long QT syndromes. Arrhythmias in a failing heart are due to abnormal calcium cycling. Potential targets for genetic modulation include the sarcoplasmic reticulum calcium pump, calsequestrin and sodium calcium exchanger.Lastly the ethical concerns need to be addressed.

  7. Gated cardiac blood pool studies in arrhythmias

    International Nuclear Information System (INIS)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed [fr

  8. Gated cardiac blood pool studies in arrhythmias

    Energy Technology Data Exchange (ETDEWEB)

    Itti, R.; Casset, D.; Philippe, L.; Cosnay, P.; Fauchier, J.P.

    1988-01-01

    Biventricular phase analysis a gated blood pool studies may help to solve two fundamental questions raised by patients suffering from arrhythmias: localization of an electrical cardiac activation abnormality by means of contraction mapping and assesment of an underlying organic disease using the phase histograms and their standard deviations. Three groups of patients have been evaluated to demonstrate the usefulness of radioisotopic techniques in arrhythmias: 36 patients with a Wolff-Parkinson-White syndrom, 27 patients studied during a ventricular tachycardia attack and 32 patients suspected of arrhythmogenic ventricular dysplasia. Correlations with invasive electrophysiologic studies are presented and the diagnostic and therapeutic implications of these results are discussed.

  9. Observational cohort study of ventricular arrhythmia in adults with Marfan syndrome caused by FBN1 mutations.

    Directory of Open Access Journals (Sweden)

    Ali Aydin

    Full Text Available Marfan syndrome is associated with ventricular arrhythmia but risk factors including FBN1 mutation characteristics require elucidation.We performed an observational cohort study of 80 consecutive adults (30 men, 50 women aged 42±15 years with Marfan syndrome caused by FBN1 mutations. We assessed ventricular arrhythmia on baseline ambulatory electrocardiography as >10 premature ventricular complexes per hour (>10 PVC/h, as ventricular couplets (Couplet, or as non-sustained ventricular tachycardia (nsVT, and during 31±18 months of follow-up as ventricular tachycardia (VT events (VTE such as sudden cardiac death (SCD, and sustained ventricular tachycardia (sVT. We identified >10 PVC/h in 28 (35%, Couplet/nsVT in 32 (40%, and VTE in 6 patients (8%, including 3 with SCD (4%. PVC>10/h, Couplet/nsVT, and VTE exhibited increased N-terminal pro-brain natriuretic peptide serum levels(P10/h and Couplet/nsVT also related to increased indexed end-systolic LV diameters (P = .024 and P = .020, to moderate mitral valve regurgitation (P = .018 and P = .003, and to prolonged QTc intervals (P = .001 and P = .006, respectively. Moreover, VTE related to mutations in exons 24-32 (P = .021. Kaplan-Meier analysis corroborated an association of VTE with increased NT-proBNP (P<.001 and with mutations in exons 24-32 (P<.001.Marfan syndrome with causative FBN1 mutations is associated with an increased risk for arrhythmia, and affected persons may require life-long monitoring. Ventricular arrhythmia on electrocardiography, signs of myocardial dysfunction and mutations in exons 24-32 may be risk factors of VTE.

  10. Targeting sodium channels in cardiac arrhythmia

    NARCIS (Netherlands)

    Remme, Carol Ann; Wilde, Arthur A. M.

    2014-01-01

    Cardiac voltage-gated sodium channels are responsible for proper electrical conduction in the heart. During acquired pathological conditions and inherited sodium channelopathies, altered sodium channel function causes conduction disturbances and ventricular arrhythmias. Although the clinical,

  11. Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.

    Science.gov (United States)

    Soucek, Filip; Starek, Zdenek

    2018-05-23

    Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Disease management: atrial fibrillation and home monitoring.

    Science.gov (United States)

    Ricci, Renato Pietro

    2013-06-01

    Device-detected atrial fibrillation (AF) episodes predict poor clinical outcome regardless of symptoms. Potential benefits of remote monitoring are early arrhythmia detection and patient continuous monitoring. Several studies of device remote monitoring consistently demonstrated that AF represents the most common clinical alert and that detailed information on arrhythmia onset, duration, and burden as well as on the ventricular rate may be early available for clinical evaluation. Reaction time to AF alerts was very short in all series involving either pacemakers or defibrillators and action ability of AF alerts was very high. In the Home Guide Registry, in which 1650 patients were enrolled, AF was detected in 16.3% of patients and represented 36% of all cardiovascular events during the follow-up. Timely anticoagulation introduction in asymptomatic patients may impact on the stroke rate. According to the results of repeated Monte Carlo simulations based on a real population of 166 patients, daily monitoring may reduce the 2-year stroke risk by 9-18% with an absolute reduction of 0.2-0.6%, compared with conventional inter-visit intervals of 6-12 months. In the COMPAS trial, the incidence of hospitalizations for atrial arrhythmias and related stroke was significantly higher in the control group than in the remote monitoring group. Major questions will be addressed by the ongoing IMPACT trial in which a remote monitoring guided anticoagulation strategy based on AF detection will be compared with a physician-directed standard strategy. In patients with heart failure, AF early detection combined with other indexes may help prevent hospitalizations.

  13. ECG scaling properties of cardiac arrhythmias using detrended fluctuation analysis

    International Nuclear Information System (INIS)

    Rodriguez, E; Echeverria, J C; Alvarez-Ramirez, J; Lerma, C

    2008-01-01

    We applied detrended fluctuation analysis to characterize at very short time scales during episodes of cardiac arrhythmias the raw electrocardiogram (ECG) waveform, aiming to get a global insight into its dynamical behaviour in patients who experienced sudden death. We found that in 15 recordings involving different types of arrhythmias (taken from PhysioNet's Sudden Cardiac Death Holter Database), the ECG waveform, besides showing a less-random dynamics, becomes more regular during bigeminy, ventricular tachycardia or even atrial fibrillation and ventricular fibrillation. The ECG waveform scaling properties thus suggest that reduced complexity dominates the underlying mechanisms of arrhythmias. Among other explanations, this may result from shorted or restricted (i.e. less diverse) pathways of conduction of the electrical activity within ventricles

  14. Design of a cardiac monitor in terms of parameters of QRS complex.

    Science.gov (United States)

    Chen, Zhen-cheng; Ni, Li-li; Su, Ke-ping; Wang, Hong-yan; Jiang, Da-zong

    2002-08-01

    Objective. To design a portable cardiac monitor system based on the available ordinary ECG machine and works on the basis of QRS parameters. Method. The 80196 single chip microcomputer was used as the central microprocessor and real time electrocardiac signal was collected and analyzed [correction of analysized] in the system. Result. Apart from the performance of an ordinary monitor, this machine possesses also the following functions: arrhythmia analysis, HRV analysis, alarm, freeze, and record of automatic papering. Convenient in carrying, the system is powered by AC or DC sources. Stability, low power and low cost are emphasized in the hardware design; and modularization method is applied in software design. Conclusion. Popular in usage and low cost made the portable monitor system suitable for use under simple conditions.

  15. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    Science.gov (United States)

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  16. Associations between arrhythmia episodes and temporally and spatially resolved black carbon and particulate matter in elderly patients

    Science.gov (United States)

    Zanobetti, Antonella; Coull, Brent A.; Gryparis, Alexandros; Kloog, Itai; Sparrow, David; Vokonas, Pantel S; Wright, Robert O.; Gold, Diane R; Schwartz, Joel

    2015-01-01

    Objectives Ambient air pollution has been associated with sudden deaths, some of which are likely due to ventricular arrhythmias. Defibrillator discharge studies have examined the association of air pollution with arrhythmias in sensitive populations. No studies have assessed this association using residence-specific estimates of air pollution exposure. Methods In the Normative Aging Study, we investigated the association between temporally-and spatially-resolved black carbon (BC) and PM2.5 and arrhythmia episodes (bigeminy, trigeminy or couplets episodes) measured as ventricular ectopy (VE) by 4-min electrocardiogram (ECG) monitoring in repeated measures of 701 subjects, during the years 2000 to 2010. We used a binomial distribution (having or not a VE episode) in a mixed effect model with a random intercept for subject, controlling for seasonality, temperature, day of the week, medication use, smoking, having diabetes, BMI and age. We also examined whether these associations were modified by genotype or phenotype. Results We found significant increases in VE with both pollutants and lags; for the estimated concentration averaged over the three days prior to the health assessment we found increases in the odds of having VE with an OR of 1.52 (95% CI: 1.19–1.94) for an IQR (0.30 μg/m3) increase in BC and an OR of 1.39 (95% CI: 1.12–1.71) for an IQR (5.63 μg/m3) increase in PM2.5. We also found higher effects in subjects with the GSTT1 and GSTM1 variants and in obese (P-valuespollutants may increase the risk of ventricular arrhythmia in elderly subjects. PMID:24142987

  17. Channelopathies - Emerging Trends in The Management of Inherited Arrhythmias

    Directory of Open Access Journals (Sweden)

    Priya Chockalingam, MBBS, MRCPCH, PhD

    2015-01-01

    Full Text Available In spite of their relative rarity, inheritable arrhythmias have come to the forefront as a group of potentially fatal but preventable cause of sudden cardiac death in children and (young adults. Comprehensive management of inherited arrhythmias includes diagnosing and treating the proband and identifying and protecting affected family members. This has been made possible by the vast advances in the field of molecular biology enabling better understanding of the genetic underpinnings of some of these disease groups, namely congenital long QT syndrome, catecholaminergic polymorphic ventricular tachycardia and Brugada syndrome. The ensuing knowledge of the genotype-phenotype correlations enables us to risk-stratify, prognosticate and treat based on the genetic test results. The various diagnostic modalities currently available to us, including clinical tools and genetic technologies, have to be applied judiciously in order to promptly identify those affected and to spare the emotional burden of a potentially lethal disease in the unaffected individuals. The therapeutic armamentarium of inherited arrhythmias includes pharmacological agents, device therapies and surgical interventions. A treatment strategy keeping in mind the risk profile of the patients, the local availability of drugs and the expertise of the treating personnel is proving effective. While opportunities for research are numerous in this expanding field of medicine, there is also tremendous scope for incorporating the emerging trends in managing patients and families with inherited arrhythmias in the Indian subcontinent.

  18. Effect of different doses of oxytocin on cardiac electrophysiology and arrhythmias induced by ischemia.

    Science.gov (United States)

    Houshmand, Fariba; Faghihi, Mahdieh; Imani, Alireza; Kheiri, Soleiman

    2017-01-01

    The onset of acute myocardial ischemia (MI) is accompanied by a rapid increase in electrical instability and often fatal ventricular arrhythmias. This study investigated that whether oxytocin (OT) can modulate ischemia-induced arrhythmias and considered relationships between the severity of arrhythmia and the electrocardiogram parameters during ischemia. OT (0.0001-1 μg) was administrated intraperitoneally 30 min before ischemia. To examine receptor involved, a selective OT-receptor antagonist, atosiban (ATO), was infused 10 min before OT. OT caused a significant and biphasic dose-dependent reduction in ectopic heart activity and arrhythmia score. OT doses that reduced ventricular arrhythmia elicited significant increase in QT interval. OT attenuated the electrophysiological changes associated with MI and there was significant direct relationship between QRS duration and arrhythmia score. ATO treatment reduced beneficial effects of OT on arrhythmogenesis. Nevertheless, ATO failed to alter OT effects on premature ventricular contractions. We assume that the ability of OT to modulate the electrical activity of the heart may play an important role in the antiarrhythmic actions of OT.

  19. Effect of different doses of oxytocin on cardiac electrophysiology and arrhythmias induced by ischemia

    Directory of Open Access Journals (Sweden)

    Fariba Houshmand

    2017-01-01

    Full Text Available The onset of acute myocardial ischemia (MI is accompanied by a rapid increase in electrical instability and often fatal ventricular arrhythmias. This study investigated that whether oxytocin (OT can modulate ischemia-induced arrhythmias and considered relationships between the severity of arrhythmia and the electrocardiogram parameters during ischemia. OT (0.0001–1 μg was administrated intraperitoneally 30 min before ischemia. To examine receptor involved, a selective OT-receptor antagonist, atosiban (ATO, was infused 10 min before OT. OT caused a significant and biphasic dose-dependent reduction in ectopic heart activity and arrhythmia score. OT doses that reduced ventricular arrhythmia elicited significant increase in QT interval. OT attenuated the electrophysiological changes associated with MI and there was significant direct relationship between QRS duration and arrhythmia score. ATO treatment reduced beneficial effects of OT on arrhythmogenesis. Nevertheless, ATO failed to alter OT effects on premature ventricular contractions. We assume that the ability of OT to modulate the electrical activity of the heart may play an important role in the antiarrhythmic actions of OT.

  20. The risk of arrhythmias following coronary artery bypass surgery: do smokers have a paradox effect?

    LENUS (Irish Health Repository)

    Al-Sarraf, Nael

    2010-11-01

    Smoking is reported to increase the risk of arrhythmias. However, there are limited data on its effects on arrhythmias following coronary artery bypass graft (CABG). This is a retrospective review of a prospective database of all CABG patients over an eight-year period. Our cohort (n=2813) was subdivided into: current (n=1169), former (n=837), and non-smokers (n=807). Predictors of arrhythmias following CABG in relation to smoking status were analysed. Atrial arrhythmias occurred in 942 patients (33%). Ventricular arrhythmias occurred in 48 patients (2%) and high-grade atrioventricular block occurred in five patients (0.2%). Arrhythmias were lower in current smokers than former and non-smokers (29% vs. 40% vs. 39%, respectively P<0.001). Logistic regression analysis showed 30% arrhythmia risk reduction in smokers compared to non-smokers [odds ratio (OR) 0.7, 95% confidence intervals (CI) 0.5-0.8] and this effect persisted after accounting for potential confounders while former smokers had the same risk as non-smokers (OR 1.04, CI 0.9-1.3). There were no significant differences in mortality. Smokers are less prone to develop arrhythmias following CABG. This paradox effect is lost in former smokers. This effect is possibly due to a lower state of hyper adrenergic stimulation observed in smokers than non-smokers following the stress of surgery.

  1. Atypical dengue meningitis in Makkah, Saudi Arabia with slow resolving, prominent migraine like headache, phobia, and arrhythmia

    Directory of Open Access Journals (Sweden)

    Kalakatawi H Mamdouh

    2013-01-01

    Full Text Available Although dengue meningitis is a rare presentation of dengue infection, our aim is to focus on atypical presentation of dengue meningitis that may appear in dengue endemic area like the Makkah region. We report two cases of clinical meningitis with positive dengue virus (DENV IgM in cerebrospinal fluid, followed for minimal 3 months for their prominent attacks of migraine like headache, phobia, and arrhythmia. With special consideration to attack time, type, severity, and respond to classical therapy, using regular ECG monitoring, visual analog pain score and neuropsychological assessments were done. Both cases showed resistant migraine like headaches to classic anti-migraine therapy except for strong NSAID and narcotics with tendency to have severe to extreme severe daily migraine like headache on early to late afternoon time, associated with non-fatal arrhythmias and extreme death phobia, that resolve slowly in a minimal 3 month period. In conclusion, dengue meningitis in the endemic area may present atypically.

  2. Ventricular arrhythmias in the absence of structural heart disease.

    Science.gov (United States)

    Prystowsky, Eric N; Padanilam, Benzy J; Joshi, Sandeep; Fogel, Richard I

    2012-05-15

    Ventricular arrhythmia (VA) in structurally normal hearts can be broadly considered under non-life-threatening monomorphic and life-threatening polymorphic rhythms. Monomorphic VA is classified on the basis of site of origin in the heart, and the most common areas are the ventricular outflow tracts and left ventricular fascicles. The morphology of the QRS complexes on electrocardiogram is an excellent tool to identify the site of origin of the rhythm. Although these arrhythmias are common and generally carry an excellent prognosis, rare sudden death events have been reported. Very frequent ventricular ectopy may also result in a cardiomyopathy in a minority of patients. Suppression of VA may be achieved using calcium-channel blockers, beta-adrenergic blockers, and class I or III antiarrhythmic drugs. Radiofrequency ablation has emerged as an excellent option to eliminate these arrhythmias, although certain foci including aortic cusps and epicardium may be technically challenging. Polymorphic ventricular tachycardia (VT) is rare and generally occurs in patients with genetic ion channel disorders including long QT syndrome, Brugada syndrome, catecholaminergic polymorphic VT, and short QT syndrome. Unlike monomorphic VT, these arrhythmic syndromes are associated with sudden death. While the cardiac gross morphology is normal, suggesting a structurally normal heart, abnormalities exist at the molecular level and predispose them to arrhythmias. Another fascinating area, idiopathic ventricular fibrillation and early repolarization syndrome, are undergoing research for a genetic basis. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. The predictive value of CHADS₂ risk score in post myocardial infarction arrhythmias - a Cardiac Arrhythmias and RIsk Stratification after Myocardial infArction (CARISMA) substudy

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine Huth; Gang, Uffe; Thomsen, Poul Erik Bloch

    2014-01-01

    BACKGROUND: Previous studies have shown substantially increased risk of cardiac arrhythmias and sudden cardiac death in post-myocardial infarction (MI) patients. However it remains difficult to identify the patients who are at highest risk of arrhythmias in the post-MI setting. The purpose...... of this study was to investigate if CHADS₂ score (congestive heart failure, hypertension, age ≥75 years, diabetes and previous stroke/TCI [doubled]) can be used as a risk tool for predicting cardiac arrhythmias after MI. METHODS: The study included 297 post-MI patients from the CARISMA study with left....... Patients were stratified according to CHADS₂ score at enrollment. Congestive heart failure was defined as LVEF ≤40% and NYHA class II, III or IV. RESULTS: We found significantly increased risk of an arrhythmic event with increasing CHADS₂ score (CHADS₂ score=1-2: HR=2.1 [1.1-3.9], p=0.021, CHADS₂ score ≥ 3...

  4. Protective effects of isorhynchophylline on cardiac arrhythmias in rats and guinea pigs.

    Science.gov (United States)

    Gan, Runtao; Dong, Guo; Yu, Jiangbo; Wang, Xu; Fu, Songbin; Yang, Shusen

    2011-09-01

    As one important constituent extracted from a traditional Chinese medicine, Uncaria Rhynchophylla Miq Jacks, isorhynchophylline has been used to treat hypertension, epilepsy, headache, and other illnesses. Whether isorhynchophylline protects hearts against cardiac arrhythmias is still incompletely investigated. This study was therefore aimed to examine the preventive effects of isorhynchophylline on heart arrhythmias in guinea pigs and rats and then explore their electrophysiological mechanisms. In vivo, ouabain and calcium chloride were used to establish experimental arrhythmic models in guinea pigs and rats. In vitro, the whole-cell patch-lamp technique was used to study the effect of isorhynchophylline on action potential duration and calcium channels in acutely isolated guinea pig and rat cardiomyocytes. The dose of ouabain required to induce cardiac arrhythmias was much larger in guinea pigs administered with isorhynchophylline. Additionally, the onset time of cardiac arrhythmias induced by calcium chloride was prolonged, and the duration was shortened in rats pretreated with isorhynchophylline. The further study showed that isorhynchophylline could significantly decrease action potential duration and inhibit calcium currents in isolated guinea pig and rat cardiomyocytes in a dose-dependent manner. In summary, isorhynchophylline played a remarkably preventive role in cardiac arrhythmias through the inhibition of calcium currents in rats and guinea pigs. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Risk of arrhythmia induced by psychotropic medications

    DEFF Research Database (Denmark)

    Fanoe, Søren; Kristensen, Diana; Fink-Jensen, Anders

    2014-01-01

    with psychotropic medications. The algorithm integrates the risk categories of the individual drugs and pre-disposing risk factors and suggests a prudent follow-up for patients with an increased risk. We believe this clinically manageable guideline might improve safety in the many and rapidly increasing number...... of the major mental disorders are associated with a large risk of suicide if untreated. The observed risk of malignant arrhythmia associated with treatment with psychotropic drugs calls for clinical guidelines integrating the risk of the individual drug and other potentially interacting risk factors......Several drugs used in the treatment of mental diseases are associated with an increased risk of sudden cardiac death (SCD). A general cause-relationship between the intake of these drugs and SCD is unattainable, but numerous case reports of drug-induced malignant arrhythmia and epidemiological...

  6. Induced pluripotent stem cell derived cardiomyocytes as models for cardiac arrhythmias

    Directory of Open Access Journals (Sweden)

    Maaike eHoekstra

    2012-08-01

    Full Text Available Cardiac arrhythmias are a major cause of morbidity and mortality. In younger patients, the majority of sudden cardiac deaths have an underlying Mendelian genetic cause. Over the last 15 years, enormous progress has been made in identifying the distinct clinical phenotypes and in studying the basic cellular and genetic mechanisms associated with the primary Mendelian (monogenic arrhythmia syndromes. Investigation of the electrophysiological consequences of an ion channel mutation is ideally done in the native cardiomyocyte environment. However, the majority of such studies so far have relied on heterologous expression systems in which single ion channel genes are expressed in non-cardiac cells. In some cases, transgenic mouse models haven been generated, but these also have significant shortcomings, primarily related to species differences.The discovery that somatic cells can be reprogrammed to pluripotency as induced pluripotent stem cells (iPSC has generated much interest since it presents an opportunity to generate patient- and disease-specific cell lines from which normal and diseased human cardiomyocytes can be obtained These genetically diverse human model systems can be studied in vitro and used to decipher mechanisms of disease and identify strategies and reagents for new therapies. Here we review the present state of the art with respect to cardiac disease models already generated using IPSC technology and which have been (partially characterized.Human iPSC (hiPSC models have been described for the cardiac arrhythmia syndromes, including LQT1, LQT2, LQT3-Brugada Syndrome, LQT8/Timothy syndrome and catecholaminergic polymorphic ventricular tachycardia. In most cases, the hiPSC-derived cardiomyoctes recapitulate the disease phenotype and have already provided opportunities for novel insight into cardiac pathophysiology. It is expected that the lines will be useful in the development of pharmacological agents for the management of these

  7. Effect of Cardiac Arrhythmia Simulation on Nursing Students' Knowledge Acquisition and Retention.

    Science.gov (United States)

    Tubaishat, Ahmad; Tawalbeh, Loai I

    2015-09-01

    The realistic and practical environment that simulation provides is an extremely useful part of the teaching process. Simulation is widely used in health and nursing education today. This study aims to evaluate the effect of simulation-based teaching on the acquisition and retention of arrhythmia-related knowledge among nursing students. A randomized controlled design involving a pretest-posttest was used. Nursing students were allocated randomly either to the experimental group (n = 47), who attended simulation scenarios on cardiac arrhythmia, or to the control group (n = 44) who received a traditional lecture on the same topic. A paired t test showed that the mean knowledge score at the posttest was significantly higher than at the pretest for both groups. However, participants in the experimental group demonstrated significantly increased knowledge of cardiac arrhythmia in the first and the second posttest compared with those in the control group. Thus, simulation is superior and significantly improves students' arrhythmia knowledge. © The Author(s) 2014.

  8. [Extension of cardiac monitoring function by used of ordinary ECG machine].

    Science.gov (United States)

    Chen, Zhencheng; Jiang, Yong; Ni, Lili; Wang, Hongyan

    2002-06-01

    This paper deals with a portable monitor system on liquid crystal display (LCD) based on this available ordinary ECG machine, which is low power and suitable for China's specific condition. Apart from developing the overall scheme of the system, this paper also has completed the design of the hardware and the software. The 80c196 single chip microcomputer is taken as the central microprocessor and real time electrocardiac single is data treated and analyzed in the system. With the performance of ordinary monitor, this machine also possesses the following functions: five types of arrhythmia analysis, alarm, freeze, and record of automatic pappering, convenient in carrying, with alternate-current (AC) or direct-current (DC) powered. The hardware circuit is simplified and the software structure is optimized in this paper. Multiple low power designs and LCD unit design are adopted and completed in it. Popular in usage, low in cost price, the portable monitor system will have a valuable influence on China's monitor system field.

  9. Risk of Ventricular Arrhythmia with Citalopram and Escitalopram: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Elena Qirjazi

    Full Text Available The risk of ventricular arrhythmia with citalopram and escitalopram is controversial. In this study we investigated the association between these two drugs and the risk of ventricular arrhythmia.We conducted a population-based retrospective cohort study of older adults (mean age 76 years from 2002 to 2012 in Ontario, Canada, newly prescribed citalopram (n = 137 701 or escitalopram (n = 38 436, compared to those prescribed referent antidepressants sertraline or paroxetine (n = 96 620. After inverse probability of treatment weighting using a propensity score, the baseline characteristics of the comparison groups were similar. The primary outcome was a hospital encounter with ventricular arrhythmia within 90 days of a new prescription, assessed using hospital diagnostic codes. The secondary outcome was all-cause mortality within 90 days.Citalopram was associated with a higher risk of a hospital encounter with ventricular arrhythmia compared with referent antidepressants (0.06% vs. 0.04%, relative risk [RR] 1.53, 95% confidence intervals [CI]1.03 to 2.29, and a higher risk of mortality (3.49% vs. 3.12%, RR 1.12, 95% CI 1.06 to 1.18. Escitalopram was not associated with a higher risk of ventricular arrhythmia compared with the referent antidepressants (0.03% vs. 0.04%, RR 0.84, 95% CI 0.42 to 1.68, but was associated with a higher risk of mortality (2.86% vs. 2.63%, RR 1.09, 95% CI 1.01 to 1.18.Among older adults, initiation of citalopram compared to two referent antidepressants was associated with a small but statistically significant increase in the 90-day risk of a hospital encounter for ventricular arrhythmia.

  10. Risk of Ventricular Arrhythmia with Citalopram and Escitalopram: A Population-Based Study.

    Science.gov (United States)

    Qirjazi, Elena; McArthur, Eric; Nash, Danielle M; Dixon, Stephanie N; Weir, Matthew A; Vasudev, Akshya; Jandoc, Racquel; Gula, Lorne J; Oliver, Matthew J; Wald, Ron; Garg, Amit X

    2016-01-01

    The risk of ventricular arrhythmia with citalopram and escitalopram is controversial. In this study we investigated the association between these two drugs and the risk of ventricular arrhythmia. We conducted a population-based retrospective cohort study of older adults (mean age 76 years) from 2002 to 2012 in Ontario, Canada, newly prescribed citalopram (n = 137 701) or escitalopram (n = 38 436), compared to those prescribed referent antidepressants sertraline or paroxetine (n = 96 620). After inverse probability of treatment weighting using a propensity score, the baseline characteristics of the comparison groups were similar. The primary outcome was a hospital encounter with ventricular arrhythmia within 90 days of a new prescription, assessed using hospital diagnostic codes. The secondary outcome was all-cause mortality within 90 days. Citalopram was associated with a higher risk of a hospital encounter with ventricular arrhythmia compared with referent antidepressants (0.06% vs. 0.04%, relative risk [RR] 1.53, 95% confidence intervals [CI]1.03 to 2.29), and a higher risk of mortality (3.49% vs. 3.12%, RR 1.12, 95% CI 1.06 to 1.18). Escitalopram was not associated with a higher risk of ventricular arrhythmia compared with the referent antidepressants (0.03% vs. 0.04%, RR 0.84, 95% CI 0.42 to 1.68), but was associated with a higher risk of mortality (2.86% vs. 2.63%, RR 1.09, 95% CI 1.01 to 1.18). Among older adults, initiation of citalopram compared to two referent antidepressants was associated with a small but statistically significant increase in the 90-day risk of a hospital encounter for ventricular arrhythmia.

  11. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    Directory of Open Access Journals (Sweden)

    Tanatorn Tanantong

    2015-02-01

    Full Text Available False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs, the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  12. Cardiac Arrhythmia Classification by Multi-Layer Perceptron and Convolution Neural Networks

    Directory of Open Access Journals (Sweden)

    Shalin Savalia

    2018-05-01

    Full Text Available The electrocardiogram (ECG plays an imperative role in the medical field, as it records heart signal over time and is used to discover numerous cardiovascular diseases. If a documented ECG signal has a certain irregularity in its predefined features, this is called arrhythmia, the types of which include tachycardia, bradycardia, supraventricular arrhythmias, and ventricular, etc. This has encouraged us to do research that consists of distinguishing between several arrhythmias by using deep neural network algorithms such as multi-layer perceptron (MLP and convolution neural network (CNN. The TensorFlow library that was established by Google for deep learning and machine learning is used in python to acquire the algorithms proposed here. The ECG databases accessible at PhysioBank.com and kaggle.com were used for training, testing, and validation of the MLP and CNN algorithms. The proposed algorithm consists of four hidden layers with weights, biases in MLP, and four-layer convolution neural networks which map ECG samples to the different classes of arrhythmia. The accuracy of the algorithm surpasses the performance of the current algorithms that have been developed by other cardiologists in both sensitivity and precision.

  13. Cardiac Arrhythmia Classification by Multi-Layer Perceptron and Convolution Neural Networks.

    Science.gov (United States)

    Savalia, Shalin; Emamian, Vahid

    2018-05-04

    The electrocardiogram (ECG) plays an imperative role in the medical field, as it records heart signal over time and is used to discover numerous cardiovascular diseases. If a documented ECG signal has a certain irregularity in its predefined features, this is called arrhythmia, the types of which include tachycardia, bradycardia, supraventricular arrhythmias, and ventricular, etc. This has encouraged us to do research that consists of distinguishing between several arrhythmias by using deep neural network algorithms such as multi-layer perceptron (MLP) and convolution neural network (CNN). The TensorFlow library that was established by Google for deep learning and machine learning is used in python to acquire the algorithms proposed here. The ECG databases accessible at PhysioBank.com and kaggle.com were used for training, testing, and validation of the MLP and CNN algorithms. The proposed algorithm consists of four hidden layers with weights, biases in MLP, and four-layer convolution neural networks which map ECG samples to the different classes of arrhythmia. The accuracy of the algorithm surpasses the performance of the current algorithms that have been developed by other cardiologists in both sensitivity and precision.

  14. Short-term Effects of High-Dose Caffeine on Cardiac Arrhythmias in Patients With Heart Failure: A Randomized Clinical Trial.

    Science.gov (United States)

    Zuchinali, Priccila; Souza, Gabriela C; Pimentel, Maurício; Chemello, Diego; Zimerman, André; Giaretta, Vanessa; Salamoni, Joyce; Fracasso, Bianca; Zimerman, Leandro I; Rohde, Luis E

    2016-12-01

    The presumed proarrhythmic action of caffeine is controversial. Few studies have assessed the effect of high doses of caffeine in patients with heart failure due to left ventricular systolic dysfunction at high risk for ventricular arrhythmias. To compare the effect of high-dose caffeine or placebo on the frequency of supraventricular and ventricular arrhythmias, both at rest and during a symptom-limited exercise test. Double-blinded randomized clinical trial with a crossover design conducted at the heart failure and cardiac transplant clinic of a tertiary-care university hospital. The trial included patients with chronic heart failure with moderate-to-severe systolic dysfunction (left ventricular ejection fraction capsules, in addition to 5 doses of 100 mL decaffeinated coffee at 1-hour intervals, for a total of 500 mg of caffeine or placebo during a 5-hour protocol. After a 1-week washout period, the protocol was repeated. Number and percentage of ventricular and supraventricular premature beats assessed by continuous electrocardiographic monitoring. We enrolled 51 patients (37 [74%] male; mean [SD] age, 60.6 [10.9] years) with predominantly moderate-to-severe left ventricular systolic dysfunction (mean [SD] left ventricular ejection fraction, 29% [7%]); 31 [61%] had an implantable cardioverter-defibrillator device. No significant differences between the caffeine and placebo groups were observed in the number of ventricular (185 vs 239 beats, respectively; P = .47) and supraventricular premature beats (6 vs 6 beats, respectively; P = .44), as well as in couplets, bigeminal cycles, or nonsustained tachycardia during continuous electrocardiographic monitoring. Exercise test-derived variables, such as ventricular and supraventricular premature beats, duration of exercise, estimated peak oxygen consumption, and heart rate, were not influenced by caffeine ingestion. We observed no increases in ventricular premature beats (91 vs 223 vs 207 beats, respectively

  15. Cardiac arrhythmias during aerobatic flight and its simulation on a centrifuge.

    Science.gov (United States)

    Zawadzka-Bartczak, Ewelina K; Kopka, Lech H

    2011-06-01

    It is well known that accelerations during centrifuge training and during flight can provoke cardiac arrhythmias. Our study was designed to investigate both the similarities and differences between heart rhythm disturbances during flights and centrifuge tests. There were 40 asymptomatic, healthy pilots who performed two training flights and were also tested in a human centrifuge according to a program of rapid onset rate acceleration (ROR) and of centrifuge simulation of the actual acceleration experienced in flight (Simulation). During the flight and centrifuge tests ECG was monitored with the Holter method. ECG was examined for heart rhythm changes and disturbances. During flights, premature ventricular contractions (PVCs) were found in 25% of the subjects, premature supraventricular contractions (PSVCs) and PVCs with bigeminy in 5%, and pairs of PVCs in 2.5% of subjects. During the centrifuge tests, PVCs were experienced by 45% of the subjects, PSVCs and pairs of PVCs by 7.5%, and PVCs with bigeminy by 2.5%. Sinus bradycardia was observed during flights and centrifuge tests in 7.5% of subjects. Comparative evaluation of electrocardiographic records in military pilots during flights and centrifuge tests demonstrated that: 1) there were no clinically significant arrhythmias recorded; and 2) the frequency and kind of heart rhythm disturbances during aerobatic flight and its simulation on a centrifuge were not identical and did not occur repetitively in the same persons during equal phases of the tests.

  16. Monitor de eventos electrocardiacos implementado en plataforma PDA Monitor of cardiac events implemented in PDA platform

    Directory of Open Access Journals (Sweden)

    John Bustamante

    Full Text Available El monitoreo ambulatorio de eventos electrocardiacos es una herramienta valiosa en el diagnóstico de arritmias cardiacas, involucradas en procesos patológicos como miocardiopatías, estadios post-infarto, lesiones del sistema autónomo cardiaco, etc.; infortunadamente aún no es posible su uso extensivo debido a los altos costos que implica la adquisición de estos equipos. Con este propósito, se diseña y desarrolla mediante el uso de asistentes digitales personales, un monitor de eventos cardiacos con capacidad de grabación pre-sintomática y post-sintomática, visualización de señal electrocardiográfica en tiempo real, grabación automática de bradicardias y taquicardias, y posibilidad de anotación de síntomas por parte del paciente. Para ello se desarrolló un componente de hardware para la adquisición y tratamiento de las señales, un software para el monitoreo en plataforma Palm OS® y una aplicación para la descarga y análisis de los datos almacenados. Las validaciones del prototipo se realizaron mediante un simulador electrocardiográfico, un simulador de arritmias basado en registros de la base de datos de arritmias del Massachusetts Institute of Technology y Beth Israel Hospital, y pruebas piloto con personas sanas y pacientes con arritmias. En este reporte preliminar se enseña cómo el prototipo desarrollado, constituye una alternativa viable para el monitoreo ambulatorio de arritmias aprovechando las capacidades de almacenamiento, procesamiento y visualización con que cuentan los asistentes digitales actuales, con la ventaja adicional de que su uso no está restringido a una sola utilidad y su accesibilidad económica se facilita debido a su amplia disponibilidad comercial.Ambulatory monitoring of electro-cardiac events constitutes a valuable tool in the diagnosis of cardiac arrhythmias involved in pathologic processes such as myocardiopathies, post-infarction stages, autonomous cardiac system injuries, etc

  17. Hypertension and Cardiac Arrhythmias

    DEFF Research Database (Denmark)

    Lip, Gregory Y H; Coca, Antonio; Kahan, Thomas

    2017-01-01

    Hypertension (HTN) is a common cardiovascular risk factor leading to heart failure (HF), coronary artery disease (CAD), stroke, peripheral artery disease and chronic renal failure. Hypertensive heart disease can manifest as many types of cardiac arrhythmias, most commonly being atrial fibrillation......) Council on Hypertension convened a Task Force, with representation from the Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE), with the remit of comprehensively reviewing the available evidence...

  18. [The Key Technology Study on Cloud Computing Platform for ECG Monitoring Based on Regional Internet of Things].

    Science.gov (United States)

    Yang, Shu; Qiu, Yuyan; Shi, Bo

    2016-09-01

    This paper explores the methods of building the internet of things of a regional ECG monitoring, focused on the implementation of ECG monitoring center based on cloud computing platform. It analyzes implementation principles of automatic identifi cation in the types of arrhythmia. It also studies the system architecture and key techniques of cloud computing platform, including server load balancing technology, reliable storage of massive smalfi les and the implications of quick search function.

  19. Exercising arrhythmias and sudden cardiac death in horses: Review of the literature and comparative aspects.

    Science.gov (United States)

    Navas de Solis, C

    2016-07-01

    Arrhythmias are common in equine athletes during and immediately after exercise. Many of these rhythm variations are not clinically relevant. In horses, a link between different exercising arrhythmias and poor performance or between exercising arrhythmias and sudden cardiac death (SCD) is strongly suspected but not fully understood or proven. SCD during races or competitions is rare, but has catastrophic consequences for the safety of the human partner and public perceptions of welfare during equestrian sports. This review summarises current knowledge of equine exercise arrhythmias and their implications in SCD and compares existing principles and recommendations for equine subjects with those for human athletes. © 2016 EVJ Ltd.

  20. Thyroid hormones and cardiac arrhythmias

    Czech Academy of Sciences Publication Activity Database

    Tribulová, N.; Knezl, V.; Shainberg, A.; Seki, S.; Soukup, Tomáš

    2010-01-01

    Roč. 52, 3-4 (2010), s. 102-112 ISSN 1537-1891 R&D Projects: GA ČR(CZ) GA304/08/0256 Grant - others:VEGA(SK) 2/0049/09; APVV(SK) 51-059505; APVV(SK) 51-017905 Institutional research plan: CEZ:AV0Z50110509 Keywords : thyroid hormone * arrhythmias * ion channels * connexin-43 Subject RIV: FA - Cardiovascular Disease s incl. Cardiotharic Surgery Impact factor: 2.174, year: 2010

  1. Arrhythmias and conduction abnormalities in children after repair of tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Kuzevska-Maneva Konstandina

    2005-01-01

    Full Text Available Aim. To find out types and frequency of cardiac arrhythmias and conduction abnormalities in the group of children who underwent surgery for tetralogy of Fallot (TOF. Methods. Fortysix pedicatric patients who underwent a complete repair of TOF at the age of 1 to 13 (mean 2.89 ± 2.36 were studied. Thirty-eight (82.60% had total correction and 8 (17.40% had palliative operation first, and total correction afterwards. Twenty-four-hour Holter ECG monitoring was performed in all 46 pediatric patients aged from 1 to 16 yrs (mean 6.48 ± 4.04 after surgery as follows: in 1 patient (2.17% after a year, in 20 patients (43.47% after 2 to 5 years and in 25 patients (54.34% after 5 years. Mean age of patients on Holter monitoring was 9.25 ± 4.39 (range 4−19. Twenty of them (43.47% were girls and 28 (56.53% were boys. All the patients were evaluated by standard methods (clinical signs, clinical findings, ECG before surgery, ECG before Holter monitoring and 2D Doppler echocardiography. Results. Types of heart rhythm found out by Holter monitoring were: sinus nodus dysfunction in 1 child (2.17%, significant premature atrial contraction (PAC in 8 (17.39%, supraventricular paroxysmal tachycardia in 3 (6.53%, transient nodal rhythm in 2 (4.34%, premature ventricular contraction (PVC Lown grade I-III in 9 (19.56% and Lown grade IV in 2 (4.34, atrioventricular (AV block grade I in 2, right bundle branch block (RBBB in all 46 (100% and RBBB + left anterior hemiblock (LAH in 4 (8.96%. There was no presence of atrial flutter, ventricular tachycardia or complete AV block. None of them experienced sudden death. Using cross procedure statistical methods, it was found that all the patients with PVC had right ventricular dilatation. There was no relation of other types of arrhythmia found on Holter monitoring to the other parameters from echocardiography, neither to the other standard methods. Children did not need the pace-maker, but 36.95% of the them required

  2. Immediate postoperative digitalization in the prophylaxis of supraventricular arrhythmias following coronary artery bypass.

    Science.gov (United States)

    Csicsko, J F; Schatzlein, M H; King, R D

    1981-03-01

    Regimens of acute preoperative digitalization have been evaluated previously in the prophylaxis of supraventricular tachycardias (SVT) following coronary artery bypass operations, with equivocal results. This study assesses the effectiveness of immediate postoperative digitalization on the incidence of arrhythmias in 407 consecutive patients recovering from myocardial revascularization. In 137 patients treated by our regimen, which begins digitalization within 4 hours postoperatively, the incidence of supraventricular tachyarrhythmias was 2%, while the corresponding figure for 270 untreated patients was 15%. Digitalization reduced the incidence of supraventricular arrhythmias significantly (p less than 0.01), whereas death, ventricular ectopy, and infarction rates were similar in the two groups. The few patients who did have supraventricular arrhythmias while receiving prophylactic digoxin were no more easily treated than patients in the undigitalized group. The timing of administration of digoxin for SVT prophylaxis may be more important than previously recognized. Immediately postoperative digitalization, theoretically preferable to preoperative regimens, is a safe, effective way to reduce the incidence of supraventricular arrhythmias following myocardial revascularization.

  3. [Observation of antiarrhythmic effects of Cinnamomum migao H. W. Li on experimental arrhythmia].

    Science.gov (United States)

    Sui, Y; Qiu, D; Xie, C; Chen, K

    1998-08-01

    To investigate the effects of Cinnamomum migao on experimental arrhythmia. Arrhythmic models of mice, rabbits, guinea pigs and rats were built using chloroform(Chl), adrenalin(Adr), strophanthin-K (Spt-K) and barium chloride (BaCl2). The affected animals were divided randomly into three groups: control group, Cinnamomum migao (CV-3) group and mexiletine (MXL) group, so as to observe and compare the antiarrhythmic effects. CV-3 could reduce the incidence of ventricular fibrillation caused by ch1 in mice and the ventricular tachycardia induced by Adr in rabbits, delay the onset time of this arrhythmia, increase the arrhythmic doses of Spt-K in guinea pigs, reduce the incidence of some arrhythmia caused by BaCl2 in rats and slow down their heart rate. CV-3 has obvious antiarrhythmic effects on experimental arrhythmia. The mechanism of these effects is probably related to the arrest of the intraflow of Na+, Ca2+ in the cardiac cells and the depression of their cardiac autoarrhythmicity and conductivity.

  4. Gene Therapy in Cardiac Arrhythmias

    OpenAIRE

    Praveen, S.V; Francis, Johnson; Venugopal, K

    2006-01-01

    Gene therapy has progressed from a dream to a bedside reality in quite a few human diseases. From its first application in adenosine deaminase deficiency, through the years, its application has evolved to vascular angiogenesis and cardiac arrhythmias. Gene based biological pacemakers using viral vectors or mesenchymal cells tested in animal models hold much promise. Induction of pacemaker activity within the left bundle branch can provide stable heart rates. Genetic modification of the AV...

  5. Long-term neurodevelopmental outcome after fetal arrhythmia

    NARCIS (Netherlands)

    Lopriore, Enrico; Aziz, Muhammed I.; Nagel, Helene T.; Blom, Nico A.; Rozendaal, Lieke; Kanhai, Humphrey H. H.; Vandenbussche, Frank P. H. A.

    2009-01-01

    OBJECTIVE: The purpose of this study was to determine the long-term neurodevelopmental outcome in fetuses with severe tachy- or bradyarrhythmia. STUDY DESIGN: This was a follow-up study to assess the neurologic, mental, and psychomotor development in cases with fetal cardiac arrhythmia. RESULTS: A

  6. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Tassi, Eduardo Marinho, E-mail: etassi@ibest.com.br [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Continentino, Marcelo Abramoff [Hospital Frei Galvão, Guaratinguetá, SP (Brazil); Nascimento, Emília Matos do; Pereira, Basílio de Bragança [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Coppe - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - UFRJ, Rio de Janeiro, RJ (Brazil); Pedrosa, Roberto Coury [Instituto de Cardiologia Edson Saad - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2014-05-15

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups.

  7. Relationship between Fibrosis and Ventricular Arrhythmias in Chagas Heart Disease Without Ventricular Dysfunction

    International Nuclear Information System (INIS)

    Tassi, Eduardo Marinho; Continentino, Marcelo Abramoff; Nascimento, Emília Matos do; Pereira, Basílio de Bragança; Pedrosa, Roberto Coury

    2014-01-01

    Patients with Chagas disease and segmental wall motion abnormality (SWMA) have worse prognosis independent of left ventricular ejection fraction (LVEF). Cardiac magnetic resonance (CMR) is currently the best method to detect SWMA and to assess fibrosis. To quantify fibrosis by using late gadolinium enhancement CMR in patients with Chagas disease and preserved or minimally impaired ventricular function (> 45%), and to detect patterns of dependence between fibrosis, SWMA and LVEF in the presence of ventricular arrhythmia. Electrocardiogram, treadmill exercise test, Holter and CMR were carried out in 61 patients, who were divided into three groups as follows: (1) normal electrocardiogram and CMR without SWMA; (2) abnormal electrocardiogram and CMR without SWMA; (3) CMR with SWMA independently of electrocardiogram. The number of patients with ventricular arrhythmia in relation to the total of patients, the percentage of fibrosis, and the LVEF were, respectively: Group 1, 4/26, 0.74% and 74.34%; Group 2, 4/16, 3.96% and 68.5%; and Group 3, 11/19, 14.07% and 55.59%. Ventricular arrhythmia was found in 31.1% of the patients. Those with and without ventricular arrhythmia had mean LVEF of 59.87% and 70.18%, respectively, and fibrosis percentage of 11.03% and 3.01%, respectively. Of the variables SWMA, groups, age, LVEF and fibrosis, only the latter was significant for the presence of ventricular arrhythmia, with a cutoff point of 11.78% for fibrosis mass (p < 0.001). Even in patients with Chagas disease and preserved or minimally impaired ventricular function, electrical instability can be present. Regarding the presence of ventricular arrhythmia, fibrosis is the most important variable, its amount being proportional to the complexity of the groups

  8. Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity.

    Science.gov (United States)

    Jularic, Mario; Akbulak, Ruken Özge; Schäffer, Benjamin; Moser, Julia; Nuehrich, Jana; Meyer, Christian; Eickholt, Christian; Willems, Stephan; Hoffmann, Boris A

    2018-03-01

    During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map. Published on behalf of the European Society of Cardiology. All rights reserved.

  9. Chronic cardiac arrhythmias produced by focused cobalt-60 gamma irradiation of the canine atria

    International Nuclear Information System (INIS)

    Dick, H.L.H.; Saylor, C.B.; Reeves, M.M.; Davies, M.J.

    1979-01-01

    Cardiac arrhythmias following exposure of the human heart to ionizing radiation have been reported. Earlier experiments involving irradiation of the hearts of various animals failed to consistently produce similar arrhythmias. In the present work, cobalt-60 irradiation was focused on the interatrial septum of the hearts of 12 dogs. Ten animals developed arrhythmias: These were repetive junctional and atrial tachycardias, repetitive atrial fibrillation, and type one, second-degree atrial ventricular block. The duration varied from 1 to 52 days, with onsets varying from 48 to 146 days postirradiation

  10. Cardiac arrhythmias associated with spinal cord injury

    DEFF Research Database (Denmark)

    Hector, Sven Magnus; Biering-Sørensen, Tor; Krassioukov, Andrei

    2013-01-01

    CONTEXT/OBJECTIVES: To review the current literature to reveal the incidence of cardiac arrhythmias and its relation to spinal cord injury (SCI). METHODS: Data source: MEDLINE database, 304 hits, and 32 articles were found to be relevant. The relevant articles all met the inclusion criteria: (1...

  11. The Effect of PM 10 on Ischemia- Reperfusion Induced Arrhythmias in Rats

    Directory of Open Access Journals (Sweden)

    Esmat Radmanesh

    Full Text Available ABSTRACT Epidemiological studies show that particulate matter (PM is the principal instigator of some adverse clinical symptoms involving cardiovascular diseases. PM exposure can increase experimental infarct size and potentiate myocardial ischemia and arrhythmias in experimental MI models such as ischemia-reperfusion (I/R injury.The present study was aimed to evaluate the effects of particulate matter (PM10 on ischemia- reperfusion induced arrhythmias with emphasis on the protective role of VA as an antioxidant on them. Male Wistar rats were divided into 8 groups (n=10: Control, VAc, Sham, VA, PM1 (0.5 mg/kg, PM2 (2.5 mg/kg, PM3 group (5 mg/kg, PM3 + VA group. Within 48 hours, PM10 was instilled into trachea in two stages. Then the hearts were isolated, transferred to a Langendorff apparatus, and subjected to global ischemia (30 minutes followed by reperfusion (60 minutes. The ischemia- reperfusion induced ventricular arrhythmias were assessed according to the Lambeth conventions.In the present study,the number, incidence and duration of arrhythmiasduring30 minutes ischemia were demonstrated to be more than those in the reperfusion stage. PM exposure increased significantly the number, incidence and duration of arrhythmias in the ischemia and reperfusion duration. Vanillic acid reduced significantly the number, incidence and duration of arrhythmias during the ischemia and reperfusion period.In summary, the results of this study demonstrated that the protective and dysrhythmic effects of VA in the PM exposure rats in I/R model are probably related to its antioxidant properties.

  12. Recommendations regarding dietary intake and caffeine and alcohol consumption in patients with cardiac arrhythmias: what do you tell your patients to do or not to do?

    Science.gov (United States)

    Glatter, Kathryn A; Myers, Richard; Chiamvimonvat, Nipavan

    2012-10-01

    The etiology of arrhythmias including atrial fibrillation is multifactorial. Most arrhythmias are associated with comorbid illnesses like hypertension, diabetes, thyroid disease, or advanced age. Although it is tempting to blame a stimulant like caffeine as a trigger for arrhythmias, the literature does not support this idea. There is no real benefit to having patients with arrhythmias limit their caffeine intake. Caffeine is a vasoactive substance that also may promote the release of norepinephrine and epinephrine. However, acute ingestion of caffeine (as coffee or tea) does not cause atrial fibrillation. Even patients suffering a myocardial infarction do not have an increased incidence of ventricular or other arrhythmias after ingesting several cups of coffee. Large epidemiologic studies have also failed to find a connection between the amount of coffee/caffeine used and the development of arrhythmias. As such, it does not make sense to suggest that patients with palpitations, paroxysmal atrial fibrillation, or supraventricular tachycardia, abstain from caffeine use. Energy drinks are a new phenomenon on the beverage market, with 30-50 % of young adults and teens using them regularly. Energy drinks are loaded with caffeine, sugar, and other chemicals that can stimulate the cardiac system. There is an increasing body of mainly anecdotal case reports describing arrhythmias or even sudden death triggered by exercise plus using energy drinks. Clearly, there must be more study in this area, but it is wise to either limit or avoid their use in patients with arrhythmias. Moderate to heavy alcohol use seems to be associated with the development of atrial fibrillation. The term "holiday heart" was coined back in 1978, to describe patients who had atrial fibrillation following binge alcohol use. Thus, it is reasonable to recommend to patients with arrhythmias that they limit their alcohol use, although unfortunately this treatment will likely not completely resolve their

  13. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    International Nuclear Information System (INIS)

    Braceli, Agustín Iriart; Morani, Jorge Exequiel

    2011-01-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  14. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    Science.gov (United States)

    Iriart Braceli, Agustín; Exequiel Morani, Jorge

    2011-12-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  15. Electromechanical wave imaging for arrhythmias

    International Nuclear Information System (INIS)

    Provost, Jean; Nguyen, Vu Thanh-Hieu; Legrand, Diégo; Okrasinski, Stan; Costet, Alexandre; Konofagou, Elisa E; Gambhir, Alok; Garan, Hasan

    2011-01-01

    Electromechanical wave imaging (EWI) is a novel ultrasound-based imaging modality for mapping of the electromechanical wave (EW), i.e. the transient deformations occurring in immediate response to the electrical activation. The correlation between the EW and the electrical activation has been established in prior studies. However, the methods used previously to map the EW required the reconstruction of images over multiple cardiac cycles, precluding the application of EWI for non-periodic arrhythmias such as fibrillation. In this study, new imaging sequences are developed and applied based on flash- and wide-beam emissions to image the entire heart at very high frame rates (2000 fps) during free breathing in a single heartbeat. The methods are first validated by imaging the heart of an open-chest canine while simultaneously mapping the electrical activation using a 64-electrode basket catheter. Feasibility is then assessed by imaging the atria and ventricles of closed-chest, conscious canines during sinus rhythm and during right-ventricular pacing following atrio-ventricular dissociation, i.e., during a non-periodic rhythm. The EW was validated against electrode measurements in the open-chest case, and followed the expected electrical propagation pattern in the closed-chest setting. These results indicate that EWI can be used for the characterization of non-periodic arrhythmias in conditions similar to the clinical setting, in a single heartbeat, and during free breathing. (fast track communication)

  16. Cardiac Arrhythmia: In vivo screening in the zebrafish to overcome complexity in drug discovery.

    Science.gov (United States)

    Macrae, Calum A

    2010-07-01

    IMPORTANCE OF THE FIELD: Cardiac arrhythmias remain a major challenge for modern drug discovery. Clinical events are paroxysmal, often rare and may be asymptomatic until a highly morbid complication. Target selection is often based on limited information and though highly specific agents are identified in screening, the final efficacy is often compromised by unanticipated systemic responses, a narrow therapeutic index and substantial toxicities. AREAS COVERED IN THIS REVIEW: Our understanding of complexity of arrhythmogenesis has grown dramatically over the last two decades, and the range of potential disease mechanisms now includes pathways previously thought only tangentially involved in arrhythmia. This review surveys the literature on arrhythmia mechanisms from 1965 to the present day, outlines the complex biology underlying potentially each and every rhythm disturbance, and highlights the problems for rational target identification. The rationale for in vivo screening is described and the utility of the zebrafish for this approach and for complementary work in functional genomics is discussed. Current limitations of the model in this setting and the need for careful validation in new disease areas are also described. WHAT THE READER WILL GAIN: An overview of the complex mechanisms underlying most clinical arrhythmias, and insight into the limits of ion channel conductances as drug targets. An introduction to the zebrafish as a model organism, in particular for cardiovascular biology. Potential approaches to overcoming the hurdles to drug discovery in the face of complex biology including in vivo screening of zebrafish genetic disease models. TAKE HOME MESSAGE: In vivo screening in faithful disease models allows the effects of drugs on integrative physiology and disease biology to be captured during the screening process, in a manner agnostic to potential drug target or targets. This systematic strategy bypasses current gaps in our understanding of disease

  17. Emerging molecular therapies targeting myocardial infarction-related arrhythmias

    NARCIS (Netherlands)

    Driessen, Helen E.; van Veen, Toon A. B.; Boink, Gerard J. J.

    2017-01-01

    Cardiac disease is the leading cause of death in the developed world. Ventricular arrhythmias associated with myocardial ischaemia and/or infarction are a major contributor to cardiovascular mortality, and require improved prevention and treatment. Drugs, devices, and radiofrequency catheter

  18. Multiclass Classification of Cardiac Arrhythmia Using Improved Feature Selection and SVM Invariants.

    Science.gov (United States)

    Mustaqeem, Anam; Anwar, Syed Muhammad; Majid, Muahammad

    2018-01-01

    Arrhythmia is considered a life-threatening disease causing serious health issues in patients, when left untreated. An early diagnosis of arrhythmias would be helpful in saving lives. This study is conducted to classify patients into one of the sixteen subclasses, among which one class represents absence of disease and the other fifteen classes represent electrocardiogram records of various subtypes of arrhythmias. The research is carried out on the dataset taken from the University of California at Irvine Machine Learning Data Repository. The dataset contains a large volume of feature dimensions which are reduced using wrapper based feature selection technique. For multiclass classification, support vector machine (SVM) based approaches including one-against-one (OAO), one-against-all (OAA), and error-correction code (ECC) are employed to detect the presence and absence of arrhythmias. The SVM method results are compared with other standard machine learning classifiers using varying parameters and the performance of the classifiers is evaluated using accuracy, kappa statistics, and root mean square error. The results show that OAO method of SVM outperforms all other classifiers by achieving an accuracy rate of 81.11% when used with 80/20 data split and 92.07% using 90/10 data split option.

  19. Arrhythmia Mechanism and Scaling Effect on the Spectral Properties of Electroanatomical Maps With Manifold Harmonics.

    Science.gov (United States)

    Sanroman-Junquera, Margarita; Mora-Jimenez, Inmaculada; Garcia-Alberola, Arcadio; Caamano, Antonio J; Trenor, Beatriz; Rojo-Alvarez, Jose L

    2018-04-01

    Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysiological studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms.

  20. Dofetilide: a new drug to control cardiac arrhythmia

    DEFF Research Database (Denmark)

    Elming, Hanne; Brendorp, Bente; Pedersen, Ole Dyg

    2003-01-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. Mortality, and especially morbidity caused by AF, are major and growing health problems in the western world. AF is strongly associated with arterial hypertension, congestive heart failure, valvular heart disease, ischaemic heart...

  1. Surgical outcome of Fontan conversion and arrhythmia surgery: Need a pacemaker?

    Science.gov (United States)

    Terada, Takafumi; Sakurai, Hajime; Nonaka, Toshimichi; Sakurai, Takahisa; Sugiura, Junya; Taneichi, Tetsuyoshi; Ohtsuka, Ryohei

    2014-07-01

    Atrial tachyarrhythmias are frequent complications in the late period after the Fontan procedure, and important risk factors for a poor prognosis. The impact of Fontan conversion and arrhythmia surgery in failed Fontan patients has been described in many reports. We evaluated our experience with Fontan conversion procedures, concomitant arrhythmia surgery, and pacemaker implantation. We reviewed the hospital records of 25 consecutive patients who underwent a Fontan conversion procedure from January 2004 to March 2012. Twenty-four patients had arrhythmia surgery using cryoablation and radiofrequency ablation at the time of conversion. A bilateral atrial maze procedure was performed in 6 patients, right-side maze in 15, and isthmus block in 3. Three patients with a diagnosis of corrected transposition of the great arteries underwent simultaneous pacemaker implantation electively. There was no early death and one late death during a mean follow-up period of 21.2 months. Three tachyarrhythmia recurrences developed, and there were 4 occurrences of sinus bradycardia. Five of these patients required postoperative pacemaker implantation. The mid-term results of Fontan conversion and arrhythmia surgery in our institute were satisfactory. The occurrence of unexpected postoperative pacemaker requirement was high in the patients who underwent a right atrial or bilateral atrial maze procedure. Pacemaker or lead implantation is recommended for patients planned to undergo a right-side or full maze procedure. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. A comparison of heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major.

    Science.gov (United States)

    Amoozgar, Hamid; Zeighami, Samaneh; Haghpanah, Sezaneh; Karimi, Mehran

    2017-01-01

    The goal of this study was to compare heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major. In this cross-sectional study, 60 patients with beta thalassemia major and 60 patients with beta thalassemia intermedia who had clinically no symptoms of arrhythmia and clinically normal heart function were evaluated using 24-hour ambulatory electrocardiogram monitoring and echocardiography. For data analysis SPSS ver.20 software was used. A P-value of less than 0.05 was considered statistically significant. The mean age of the beta thalassemia intermedia patients was 24.18 ± 7.9 years and the mean age in beta thalassemia major was 24.38 ± 7.7 years (P>0.05). Premature atrial contractions (PACs) were observed in 14 (23.3%) patients with beta thalassemia intermedia and in 22 (36.6%) beta thalassemia major patients. Premature ventricular contractions (PVCs) were detected in 8 (13.3%) patients in the beta thalassemia intermediate group and 16 (26.6) patients in the beta thalassemia major group, respectively. The left ventricular diastolic dimension, end-diastolic volume, and stroke volume were significantly higher in beta thalassemia intermedia group (Pintermedia group. Both atrial and ventricular arrhythmias were more common in the beta thalassemia major group. Higher end-diastolic volume and stroke volume were detected in the beta thalassemia intermedia group. Pulmonary acceleration time was lower in the beta thalassemia intermedia group, which can be an indicator of higher pulmonary pressure.

  3. Low-Cost Optical Mapping Systems for Panoramic Imaging of Complex Arrhythmias and Drug-Action in Translational Heart Models

    Science.gov (United States)

    Lee, Peter; Calvo, Conrado J.; Alfonso-Almazán, José M.; Quintanilla, Jorge G.; Chorro, Francisco J.; Yan, Ping; Loew, Leslie M.; Filgueiras-Rama, David; Millet, José

    2017-02-01

    Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had on the fields of cardiac arrhythmias and whole-heart computational modeling, present-day system designs precludes its adoption by the broader cardiovascular research community because of their high costs. Taking advantage of recent technological advances, we developed and validated low-cost optical mapping systems for panoramic imaging using Langendorff-perfused pig hearts, a clinically-relevant model in basic research and bioengineering. By significantly lowering financial thresholds, this powerful cardiac electrophysiology imaging modality may gain wider use in research and, even, teaching laboratories, which we substantiated using the lower-cost Langendorff-perfused rabbit heart model.

  4. Prediction of tonic parasympathetic cardiac control using respiratory sinus arrhythmia: the need for respiratory control

    NARCIS (Netherlands)

    GROSSMAN, P.; Karemaker, J.; Wieling, W.

    1991-01-01

    Respiratory sinus arrhythmia (RSA) has received much attention in recent years due to the large body of evidence indicating that variations in this phenomenon represent alterations in parasympathetic cardiac control. Although it appears that respiratory sinus arrhythmia is mediated by vagal

  5. Cardiac arrhythmia detection using combination of heart rate variability analyses and PUCK analysis.

    Science.gov (United States)

    Mahananto, Faizal; Igasaki, Tomohiko; Murayama, Nobuki

    2013-01-01

    This paper presents cardiac arrhythmia detection using the combination of a heart rate variability (HRV) analysis and a "potential of unbalanced complex kinetics" (PUCK) analysis. Detection performance was improved by adding features extracted from the PUCK analysis. Initially, R-R interval data were extracted from the original electrocardiogram (ECG) recordings and were cut into small segments and marked as either normal or arrhythmia. HRV analyses then were conducted using the segmented R-R interval data, including a time-domain analysis, frequency-domain analysis, and nonlinear analysis. In addition to the HRV analysis, PUCK analysis, which has been implemented successfully in a foreign exchange market series to characterize change, was employed. A decision-tree algorithm was applied to all of the obtained features for classification. The proposed method was tested using the MIT-BIH arrhythmia database and had an overall classification accuracy of 91.73%. After combining features obtained from the PUCK analysis, the overall accuracy increased to 92.91%. Therefore, we suggest that the use of a PUCK analysis in conjunction with HRV analysis might improve performance accuracy for the detection of cardiac arrhythmia.

  6. Effects of Statin on Arrhythmia and Heart Rate Variability in Healthy Persons With 48-Hour Sleep Deprivation.

    Science.gov (United States)

    Chen, Wei Ren; Liu, Hong Bin; Sha, Yuan; Shi, Yang; Wang, Hao; Yin, Da Wei; Chen, Yun Dai; Shi, Xiang Min

    2016-10-31

    It has been reported that sleep deprivation is associated with cardiac autonomic disorder, inflammation, and oxidative stress. Statins have significant cardiovascular protective effects in patients with cardiovascular disease. This study aimed to investigate the protective effect of statins on arrhythmia and heart rate variability in young healthy persons after 48-hour sleep deprivation. This study enrolled 72 young healthy participants aged 26.5±3.5 years. All participants received 48-hour continuous ambulatory electrocardiogram monitoring. Arrhythmia, time, and frequency domain parameters were analyzed for all participants. The primary end point, low/high frequency ratio, was significantly lower in the statin group than in the control group (2.48±1.12 versus 3.02±1.23, Psleep deprivation, low frequency-the frequency of premature atrial complexes and premature ventricular complexes-was significantly decreased in the statin group compared with the control group (Psleep deprivation in the statin group compared with the control group (Psleep deprivation. This finding should be confirmed by larger scale trials. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02496962. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  7. Dipyridamole-thallium tests are predictive of severe cardiac arrhythmias in patients with left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Saragoca, M.A.; Canziani, M.E.; Gil, M.A.; Castiglioni, M.L.; Cassiolato, J.L.; Barbieri, A.; Lima, V.C.; Draibe, S.A.; Martinez, E.E.

    1991-01-01

    In a population of patients with chronic renal failure (CRF) and a high prevalence of left ventricular hypertrophy (LVH) undergoing chronic hemodialysis, the authors investigated the association between the results of dipyridamole-thallium tests (DTTs) and the occurrence of ventricular arrhythmias. They observed a positive significant association between positive DTTs and the occurrence of severe forms of ventricular arrhythmias. A significant association was also observed between the presence of severe LVH and the occurrence of severe ventricular arrhythmias. However, no association was found between the presence of LVH and the positivity of the DTT. As most of their patients with positive DTTs had unimpaired coronary circulations, they conclude that positive DTTs, although falsely indicative of impaired myocardial blood supply, does have an important clinical relevance, indicating increased risk of morbidity (and, possibly, mortality) due to ventricular arrhythmias in a population of CRF patients submitted to chronic renal function replacement program

  8. Real-Time Analytics for the Healthcare Industry: Arrhythmia Detection.

    Science.gov (United States)

    Agneeswaran, Vijay Srinivas; Mukherjee, Joydeb; Gupta, Ashutosh; Tonpay, Pranay; Tiwari, Jayati; Agarwal, Nitin

    2013-09-01

    It is time for the healthcare industry to move from the era of "analyzing our health history" to the age of "managing the future of our health." In this article, we illustrate the importance of real-time analytics across the healthcare industry by providing a generic mechanism to reengineer traditional analytics expressed in the R programming language into Storm-based real-time analytics code. This is a powerful abstraction, since most data scientists use R to write the analytics and are not clear on how to make the data work in real-time and on high-velocity data. Our paper focuses on the applications necessary to a healthcare analytics scenario, specifically focusing on the importance of electrocardiogram (ECG) monitoring. A physician can use our framework to compare ECG reports by categorization and consequently detect Arrhythmia. The framework can read the ECG signals and uses a machine learning-based categorizer that runs within a Storm environment to compare different ECG signals. The paper also presents some performance studies of the framework to illustrate the throughput and accuracy trade-off in real-time analytics.

  9. Ischaemic stroke in hyperthyroidism without cardiac arrhythmia - A ...

    African Journals Online (AJOL)

    BACKGROUND: The relationship between hyperthyroidism and stroke is well established in the setting of atrial fibrillation. However there is limited literature for ischaemic stroke occurring in hyperthyroidism without cardiac arrhythmia. No such case had been described in South East Nigeria. METHOD: This report highlights ...

  10. Predictors of the left ventricular dysfunction induced by ventricular arrhythmia

    Directory of Open Access Journals (Sweden)

    А. І. Vytryhovskiy

    2016-08-01

    Full Text Available The most powerful predictor of life-threatening arrhythmia risk is a combination of low heart rate variability with low ejection fraction (EF of the left ventricle. Aim. To identify predictors of left ventricle dysfunction which is induced by ventricular arrhythmia. Materials and methods. To diagnose structural changes of left ventricular functional capacity and reserves in patients with previous myocardial infarction and patients with high and very high cardiovascular risk by SCORE scale and for establishment the relationship between morphological heart changes and pathological phenomenon of heart turbulence echocardiography and study of heart rate turbulence variability were performed. 603 patients were selected for the research. All patients were divided into groups: group 1 – patients with coronary heart disease, but without associated risk factors, such as smoking, obesity, metabolic syndrome; group 2 – patients who smoke tobacco more than 2 years (very high cardiovascular risk by scale SCORE; group 3 – patients with metabolic syndrome without coronary heart disease or arterial hypertension (very high cardiovascular risk by scale SCORE. The control group consisted of 149 persons. Results. The feature of structural changes in patients with myocardial infarction and in patients with a high cardiovascular risk by SCORE with heart rate turbulence compared with cases without НRT is considerably thickening of the left interventricular septum in systole. Based on this, it can be argued that the emergence of ventricular arrhythmia and accordingly phenomenon of heart rate turbulence in patients with existing cardiovascular diseases and risk factors has both morphological and functional character. Significant difference of echocardioscopy parameters in patients with postinfarction cardiosclerosis and risk factors by the SCORE system was established by index of intraventricular septum thickness in systole, and in persons with high risk – in

  11. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  12. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  13. Statins as anti-arrhythmics: a systematic review part II: effects on risk of ventricular arrhythmias.

    Science.gov (United States)

    Abuissa, Hussam; O'Keefe, James H; Bybee, Kevin A

    2009-10-01

    Recent studies have demonstrated that statins may possess anti-arrhythmic properties in addition to their lipid-lowering effects. Studies which reported the association of statins with the incidence of ventricular arrhythmias were identified through a systematic review of the published literature. Statins have been associated with a significant reductions in ventricular arrhythmia in cardiomyopathy patients with an implantable cardioverter defibrillator, although randomized trials have not been completed. Published data suggests that statins may possess anti-arrhythmic properties that reduce the propensity for ventricular arrhythmias. Most of this data is observational; more randomized, placebo-controlled trials are needed.

  14. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  15. Double hazards of ischemia and reperfusion arrhythmias in a patient with variant angina pectoris.

    Science.gov (United States)

    Xu, Mingzhu; Yang, Xiangjun

    2015-01-01

    Variant angina pectoris, also called Prinzmetal's angina, is a syndrome caused by vasospasms of the coronary arteries. It can lead to myocardial infarction, ventricular arrhythmias, atrioventricular block and even sudden cardiac death. We report the case of a 53 year-old male patient with recurrent episodes of chest pain and arrhythmias in the course of related variant angina pectoris. It is likely that the reperfusion following myocardial ischemia was responsible for the ventricular fibrillation while the ST-segment returned to the baseline. This case showed that potential lethal arrhythmias could arise due to variant angina pectoris. It also indicated that ventricular fibrillation could be self-terminated. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Decreasing the false alarm rate of arrhythmias in intensive care using a machine learning approach

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2015-01-01

    We present a novel algorithm for classifying true and false alarms of five life-threatening arrhythmias in intensive care. This algorithm was entered in the PhysioNet/Computing in Cardiology Challenge 2015 Reducing False Arrhythmia Alarms in the ICU. The algorithm performs a binary classification of

  17. Risk prediction of ventricular arrhythmias and myocardial function in Lamin A/C mutation positive subjects

    DEFF Research Database (Denmark)

    Hasselberg, Nina E; Edvardsen, Thor; Petri, Helle

    2014-01-01

    Mutations in the Lamin A/C gene may cause atrioventricular block, supraventricular arrhythmias, ventricular arrhythmias (VA), and dilated cardiomyopathy. We aimed to explore the predictors and the mechanisms of VA in Lamin A/C mutation-positive subjects.METHODS AND RESULTS: We included 41 Lamin A/C...

  18. Inhibition of N-type Ca2+ channels ameliorates an imbalance in cardiac autonomic nerve activity and prevents lethal arrhythmias in mice with heart failure.

    Science.gov (United States)

    Yamada, Yuko; Kinoshita, Hideyuki; Kuwahara, Koichiro; Nakagawa, Yasuaki; Kuwabara, Yoshihiro; Minami, Takeya; Yamada, Chinatsu; Shibata, Junko; Nakao, Kazuhiro; Cho, Kosai; Arai, Yuji; Yasuno, Shinji; Nishikimi, Toshio; Ueshima, Kenji; Kamakura, Shiro; Nishida, Motohiro; Kiyonaka, Shigeki; Mori, Yasuo; Kimura, Takeshi; Kangawa, Kenji; Nakao, Kazuwa

    2014-10-01

    Dysregulation of autonomic nervous system activity can trigger ventricular arrhythmias and sudden death in patients with heart failure. N-type Ca(2+) channels (NCCs) play an important role in sympathetic nervous system activation by regulating the calcium entry that triggers release of neurotransmitters from peripheral sympathetic nerve terminals. We have investigated the ability of NCC blockade to prevent lethal arrhythmias associated with heart failure. We compared the effects of cilnidipine, a dual N- and L-type Ca(2+) channel blocker, with those of nitrendipine, a selective L-type Ca(2+) channel blocker, in transgenic mice expressing a cardiac-specific, dominant-negative form of neuron-restrictive silencer factor (dnNRSF-Tg). In this mouse model of dilated cardiomyopathy leading to sudden arrhythmic death, cardiac structure and function did not significantly differ among the control, cilnidipine, and nitrendipine groups. However, cilnidipine dramatically reduced arrhythmias in dnNRSF-Tg mice, significantly improving their survival rate and correcting the imbalance between cardiac sympathetic and parasympathetic nervous system activity. A β-blocker, bisoprolol, showed similar effects in these mice. Genetic titration of NCCs, achieved by crossing dnNRSF-Tg mice with mice lacking CACNA1B, which encodes the α1 subunit of NCCs, improved the survival rate. With restoration of cardiac autonomic balance, dnNRSF-Tg;CACNA1B(+/-) mice showed fewer malignant arrhythmias than dnNRSF-Tg;CACNA1B(+/+) mice. Both pharmacological blockade of NCCs and their genetic titration improved cardiac autonomic balance and prevented lethal arrhythmias in a mouse model of dilated cardiomyopathy and sudden arrhythmic death. Our findings suggest that NCC blockade is a potentially useful approach to preventing sudden death in patients with heart failure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  19. [Clinical aspects of reperfusion arrhythmia following intravenous thrombolysis in acute myocardial infarct].

    Science.gov (United States)

    Kettner, W; Klein, E; Schulz, W; Götze, C

    1987-05-15

    In accordance with the majority of the reports in the literature reperfusion arrhythmias were observed in more than 30% of the patients with acute myocardial infarction (n = 25) under or immediately after a highly dosed short-term infusion with streptokinase. With reference to indirect signs the recanalisation rate was assumed with 75%. Only one third of the reperfusion arrhythmias had haemodynamically significant characteristics and required an influence. Though in literature from animal experimental findings directive conclusions for the therapy are to be derived, the procedure in practice is still vastly empirical. In the ventricular tachycardia lidocaine, procainamide and ajmalin may be recommended. In ineffectiveness or particularly threatening situations the electrotherapy (cardioversion, DC-shock) is to be preferred. The concept inaugurated by Corr and Witkowski apply alpha-adrenoreceptor blockers has not yet entered the clinical practice. Possible problems in the treatment of reperfusion arrhythmias in the prehospital phase should at present still be a reason not to antedate the thrombolytic therapy into this phase.

  20. Metabolic Syndrome Remodels Electrical Activity of the Sinoatrial Node and Produces Arrhythmias in Rats

    Science.gov (United States)

    Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia

    2013-01-01

    In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of “metabolic syndrome rats”, compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats. PMID:24250786

  1. Magnesium sulphate and amiodarone prophylaxis for prevention of postoperative arrhythmia in coronary by-pass operations

    Directory of Open Access Journals (Sweden)

    Huysal Kagan

    2009-02-01

    Full Text Available Abstract Background The aim of this study was to investigate the use of prophylactic magnesium sulphate and amiodarone in treating arrhythmias that may occur following coronary bypass grafting operations. Methods The study population consisted of 192 consecutive patients who were undergoing coronary artery bypass grafting (CABG. Sixty-four patients were given 3 g of magnesium sulphate (MgSO4 [20 ml = 24.32 mEq/L Mg+2] in 100 cc of isotonic 0.9% solution over 2 hours intravenously at the following times: 12 hours prior to the operation, immediately following the operation, and on postoperative days 1, 2, and 3 (Group 1. Another group of 64 patients was given a preoperative infusion of amiodarone (1200 mg on first post-operative day (Group 2. After the operation amiodarone was administered orally at a dose of 600 mg/day. Sixty-four patients in group 3 (control group had 100 cc. isotonic 0.9% as placebo, during the same time periods. Results In the postoperative period, the magnesium values were significantly higher in Group 1 than in Group 2 for all measurements. The use of amiodarone for total arrhythmia was significantly more effective than prophylactic treatment with magnesium sulphate (p = 0.015. There was no difference between the two drugs in preventing supraventricular arrhythmia, although amiodarone significantly delayed the revealing time of atrial fibrillation (p = 0.026. Ventricular arrhythmia, in the form of ventricular extra systole, was more common in the magnesium prophylaxis group. The two groups showed no significant differences in other operative or postoperative measurements. No side effects of the drugs were observed. Conclusion Prophylactic use of magnesium sulphate and amiodarone are both effective at preventing arrhythmia that may occur following coronary by-pass operations. Magnesium sulphate should be used in prophylactic treatment since it may decrease arrhythmia at low doses. If arrhythmia should occur despite this

  2. Syncope in old people. The importance of multiparametric monitor in OBI evaluation

    Directory of Open Access Journals (Sweden)

    Alessandro Riccardi

    2006-10-01

    Full Text Available Syncope is a common clinical entity, and it causes up to 3% of admission in the Emergency Department. The evaluation of syncope begins with a careful history, physical examination, and electrocardiography, with a correct identification of etiology at the presentation in up to 50% of cases. Moreover, the underlying cause of syncope remains unidentified in a elevated percentage of patients. The application of Standard Guidelines and the institution of the Observation Unit (OBI with continuous monitoring improves patients management, chiefly in the geriatric population (> 65 years old. In older patients the clinical features of syncope are less defined, and the medical history has a limited value. The management in the OBI of this group of patient with continuous monitoring could become the best approach. The ECG monitoring can detect life-threatening arrhythmias in older patients with apparent non cardiac syncope. In the firs six months of 2005 the Emergency Department of the Ospedale San Paolo (Savona evaluated 164 patients > 65 years old with diagnosis of syncope/pre-syncope. During monitoring we detected events of arrhythmia in 12 patients (7,3%, including ventricular tachycardia in 2, atrial fibrillation in 4, paroxysmal atrial flutter in 2, paroxysmal supraventricular tachycardia in 1, asystole in 1 and third-degree atrioventricular block in 2 patients. We briefly describe 2 of this case: in both cases the first suggestion indicates a possible non cardiac etiology, but the subsequent monitoring shows episodes of potentially fatal arrhythmia. Both an early discharge and an in non-monitorized bed admission wouldn’t have preserved the two patient by a sudden cardiac death.

  3. Life threatening arrhythmias: Knowledge and skills among nurses ...

    African Journals Online (AJOL)

    Conclusion: Although the majority of the participants scored highly in their level of knowledge regarding life threatening arrhythmias, they scored poorly in most of the observed skills when identifying and treating this patient group. It is important that hospital administration take into consideration the identified areas of ...

  4. Life threatening arrhythmias: Knowledge and skills among nurses ...

    African Journals Online (AJOL)

    User

    this study was to assess knowledge and skills of nurses in identifying life ... Much of the literature considers ventricular tachycardia, ventricular fibrillation, ... In critical care settings, bedside nurses play a critical role in arrhythmia identification and ..... Lambert, V.A. & Lambert, C.E. (2008) Nurses' workplace stressors and ...

  5. Intracoronary infusion of catecholamines causes focal arrhythmias in pigs.

    Science.gov (United States)

    Doppalapudi, Harish; Jin, Qi; Dosdall, Derek J; Qin, Hao; Walcott, Gregory P; Killingsworth, Cheryl R; Smith, William M; Ideker, Raymond E; Huang, Jian

    2008-09-01

    Acute ischemia causes myriad changes including increased catecholamines. We tested the hypothesis that elevated catecholamines alone are arrhythmogenic. A 504 electrode sock was placed over both ventricles in six open-chest pigs. During control infusion of saline through a catheter in the left anterior descending coronary artery (LAD), no sustained arrhythmias occurred, and the refractory period estimated by the activation recovery interval (ARI) was 175 +/- 14 ms in the LAD bed below the catheter. After infusion of isoproterenol at 0.1 microg/kg/min through the catheter, the ARI in this bed was significantly reduced to 109 +/- 10 ms. A sharp gradient of refractoriness of 43 +/- 10 ms was at the border of the perfused bed. Sustained monomorphic ventricular tachycardia occurred after drug infusion in the perfused bed or near its boundary in all animals with a cycle length of 329 +/- 26 ms and a focal origin. The maximum slope of the ARI restitution curve at the focal origins of the tachyarrhythmias was always <1 (0.62 +/- 0.15). Similar results with a focal arrhythmia origin occurred in two additional pigs in which intramural mapping was performed with 36 plunge needle electrodes in the left ventricular perfused bed. Regional elevation of a catecholamine, which is one of the alterations produced by acute ischemia, can by itself cause tachyarrhythmias. These arrhythmias are closely associated with a shortened refractory period and a large gradient of the spatial distribution of refractoriness but not with a steep restitution curve.

  6. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  7. Discrete potentials guided radiofrequency ablation for idiopathic outflow tract ventricular arrhythmias.

    Science.gov (United States)

    Liu, Enzhao; Xu, Gang; Liu, Tong; Ye, Lan; Zhang, Qitong; Zhao, Yanshu; Li, Guangping

    2015-03-01

    Discrete potentials (DPs) have been recorded and targeted as the site of ablation of the outflow tract arrhythmias. The aim of the present study was to investigate the significance of DPs with respect to mapping and ablation for idiopathic outflow tract premature ventricular contractions (PVCs) or ventricular tachycardias (VTs). Seventeen consecutive patients with idiopathic right or left ventricular outflow tract PVCs/VTs who underwent radiofrequency catheter ablation were included. Intracardiac electrograms during the mapping and ablation were analysed. During sinus rhythm, sharp high-frequency DPs that displayed double or multiple components were recorded following or buried in the local ventricular electrograms in all of the 17 patients, peak amplitude 0.51 ± 0.21 mV. The same potential was recorded prior to the local ventricular potential of the PVCs/VTs. Spontaneous reversal of the relationship of the DPs to the local ventricular electrogram during the arrhythmias was noted. The DPs were related to a region of low voltage showed by intracardiac high-density contact mapping. At the sites with DPs, lower unipolar and bipolar ventricular voltage of sinus beats were noted compared with the adjacent regions without DPs (unipolar: 6.1 ± 1.8 vs. 8.3 ± 2.3 mV, P Discrete potentials were not present in seven controls. Discrete potentials and related low-voltage regions were common in idiopathic outflow tract ventricular arrhythmias. Discrete potential- and substrate-guided ablation strategy will help to reduce the recurrence of idiopathic outflow tract arrhythmias. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  8. Controversies in Cardiovascular Research: Induced pluripotent stem cell-derived cardiomyocytes – boutique science or valuable arrhythmia model?

    Science.gov (United States)

    Knollmann, Björn C

    2013-01-01

    As part of the series on Controversies in Cardiovascular Research, the article reviews the strengths and limitations of induced pluripotent stem cell-derived cardiomyocytes (iPSC-CM) as models of cardiac arrhythmias. Specifically, the article attempts to answer the following questions: Which clinical arrhythmias can be modeled by iPSC-CM? How well can iPSC-CM model adult ventricular myocytes? What are the strengths and limitations of published iPSC-CM arrhythmia models? What new mechanistic insight has been gained? What is the evidence that would support using iPSC-CM to personalize anti-arrhythmic drug therapy? The review also discusses the pros and cons of using the iPSC-CM technology for modeling specific genetic arrhythmia disorders such as long QT syndrome, Brugada Syndrome or Catecholaminergic Polymorphic Ventricular Tachycardia. PMID:23569106

  9. Electroversion in treatment of arrhythmia in a patient with Wolff-Parkinson-White syndrome and cervical spinal cord injury

    Directory of Open Access Journals (Sweden)

    SHEN Peng

    2013-06-01

    Full Text Available 【Abstract】We report electroversion in treatment of atrial fibrillation (AF and atrioventricular nodal reentry ta-chycardia (AVNRT in a patient with Wolff-Parkinson-White syndrome and cervical spinal cord injury. At first, the pa-tient sustained respiratory failure and weak cough reflex, thereafter repeated bronchoscopy was used to aspirate the sputum as well as control the pneumonia, which resulted in arrhythmia (AF and AVNRT. Two doses of intravenous amiodarone failed to correct the arrhythmia. After restora-tion of sinus rhythm by electroversion, he was successfully weaned from mechanical ventilation and discharged from the intensive care unit without recurrent arrhythmia. Key words: Arrhythmia, cardiac; Atrial fibrillation; Electric countershock; Wolff-Parkinson-White syndrome; Spinal cord injuries

  10. The effect of Cardiac Arrhythmias Simulation Software on the nurses' learning and professional development.

    Science.gov (United States)

    Bazrafkan, Leila; Hemmati, Mehdi

    2018-04-01

    One of the important tasks of nurses in intensive care unit is interpretation of ECG. The use of training simulator is a new paradigm in the age of computers. This study was performed to evaluate the impact of cardiac arrhythmias simulator software on nurses' learning in the subspecialty Vali-Asr Hospital in 2016. This study was conducted by quasi-experimental randomized Salomon four group design with the participation of 120 nurses in subspecialty Vali-Asr Hospital in Tehran, Iran in 2016 that were selected purposefully and allocated in 4 groups. By this design other confounding factors such as the prior information, maturation and the role of sex and age were controlled by Solomon 4 design. The valid and reliable multiple choice test tools were used to gather information; the validity of the test was approved by experts and its reliability was obtained by Cronbach's alpha coefficient 0.89. At first, the knowledge and skills of the participants were assessed by a pre-test; following the educational intervention with cardiac arrhythmias simulator software during 14 days in ICUs, the mentioned factors were measured for the two groups again by a post-test in the four groups. Data were analyzed using the two way ANOVA. The significance level was considered as ptest results, using cardiac arrhythmias simulator software as an intervention was effective in the nurses' learning since a significant difference was found between pre-test and post-test in the first group (ptest showed that there was no interaction between pre-test and intervention in all of the three knowledge areas of cardiac arrhythmias, their treatments and their diagnosis (P>0.05). The use of software-based simulator for cardiac arrhythmias was effective in nurses' learning in light of its attractive components and interactive method. This intervention increased the knowledge of the nurses in cognitive domain of cardiac arrhythmias in addition to their diagnosis and treatment. Also, the package can be

  11. Novel energy modalities for catheter ablation of cardiac arrhythmias : Pitfalls and possibilities of potent power sources

    NARCIS (Netherlands)

    Neven, K.G.E.J.

    2014-01-01

    The acceptance of catheter ablation as treatment for cardiac arrhythmias is amongst others dependent on its success rate, a high initial success rate will increase physician and patient acceptance. One of the reasons why recurrence of arrhythmia after ablation is substantial is non-transmurality of

  12. Effects of short-term administration of estradiol on reperfusion arrhythmias in rats of different ages

    International Nuclear Information System (INIS)

    Savergnini, S.Q.; Reis, A.M.; Santos, R.A.S.; Santos, P.E.B.; Ferreira, A.J.; Almeida, A.P.

    2012-01-01

    Little is known about age-related differences in short-term effects of estradiol on ischemia-reperfusion (I/R) insults. The present study was designed to evaluate the effects of short-term treatment with estradiol on reperfusion arrhythmias in isolated hearts of 6-7-week-old and 12-14-month-old female rats. Wistar rats were sham-operated, ovariectomized and treated with vehicle or ovariectomized and treated with 17β-estradiol (E 2 ; 5 µg·100 g −1 ·day −1 ) for 4 days. Hearts were perfused by the Langendorff technique. Reperfusion arrhythmias, i.e., ventricular tachycardia and/or ventricular fibrillation, were induced by 15 min of left coronary artery ligation and 30 min of reperfusion. The duration and incidence of I/R arrhythmias were significantly higher in young rats compared to middle-aged rats (arrhythmia severity index: 9.4 ± 1.0 vs 3.0 ± 0.3 arbitrary units, respectively, P < 0.05). In addition, middle-aged rats showed lower heart rate, systolic tension and coronary flow. Four-day E 2 treatment caused an increase in uterine weight. Although E 2 administration had no significant effect on the duration of I/R arrhythmias in middle-aged rats, it induced a marked reduction in the rhythm disturbances of young rats accompanied by a decrease in heart rate of isolated hearts. Also, this reduction was associated with an increase in QT interval. No significant changes were observed in the QT interval of middle-aged E 2 -treated rats. These data demonstrate that short-term estradiol treatment protects against I/R arrhythmias in hearts of young female rats. The anti-arrhythmogenic effect of estradiol might be related to a lengthening of the QT interval

  13. Effects of short-term administration of estradiol on reperfusion arrhythmias in rats of different ages

    Energy Technology Data Exchange (ETDEWEB)

    Savergnini, S.Q.; Reis, A.M. [Departamento de Fisiologia e Biofísica, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Santos, R.A.S. [1Departamento de Fisiologia e Biofísica, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Santos, P.E.B. [Departamento de Farmacologia, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Ferreira, A.J. [Departamento de Morfologia, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Almeida, A.P. [Departamento de Fisiologia e Biofísica, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2012-11-01

    Little is known about age-related differences in short-term effects of estradiol on ischemia-reperfusion (I/R) insults. The present study was designed to evaluate the effects of short-term treatment with estradiol on reperfusion arrhythmias in isolated hearts of 6-7-week-old and 12-14-month-old female rats. Wistar rats were sham-operated, ovariectomized and treated with vehicle or ovariectomized and treated with 17β-estradiol (E{sub 2}; 5 µg·100 g{sup −1}·day{sup −1}) for 4 days. Hearts were perfused by the Langendorff technique. Reperfusion arrhythmias, i.e., ventricular tachycardia and/or ventricular fibrillation, were induced by 15 min of left coronary artery ligation and 30 min of reperfusion. The duration and incidence of I/R arrhythmias were significantly higher in young rats compared to middle-aged rats (arrhythmia severity index: 9.4 ± 1.0 vs 3.0 ± 0.3 arbitrary units, respectively, P < 0.05). In addition, middle-aged rats showed lower heart rate, systolic tension and coronary flow. Four-day E{sub 2} treatment caused an increase in uterine weight. Although E{sub 2} administration had no significant effect on the duration of I/R arrhythmias in middle-aged rats, it induced a marked reduction in the rhythm disturbances of young rats accompanied by a decrease in heart rate of isolated hearts. Also, this reduction was associated with an increase in QT interval. No significant changes were observed in the QT interval of middle-aged E{sub 2}-treated rats. These data demonstrate that short-term estradiol treatment protects against I/R arrhythmias in hearts of young female rats. The anti-arrhythmogenic effect of estradiol might be related to a lengthening of the QT interval.

  14. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  15. Geometric patterns of time-delay plots from different cardiac rhythms and arrhythmias using short-term EKG signals.

    Science.gov (United States)

    Borracci, Raúl A; Montoya Pulvet, José D; Ingino, Carlos A; Fitz Maurice, Mario; Hirschon Prado, Alfredo; Dominé, Enrique

    2017-12-27

    To date, no systematic work has been intended to describe spatio-temporal patterns of cardiac rhythms using only short series of RR intervals, to facilitate visual or computerized-aided identification of EKG motifs for use in clinical practice. The aim of this study was to detect and classify eye-catching geometric patterns of Poincaré time-delay plots from different types of cardiac rhythms and arrhythmias using short-term EKG signals. Approximately 150-300 representative, consecutive beats were retrieved from 24-h Holter registers of 100 patients with different heart rhythms. Two-dimensional Poincaré charts were created, and the resulting geometric patterns were transformed into representative familiar eye-catching drawings to interpret different arrhythmias. Poincaré plot representation of RR interval data revealed a wide variety of visual patterns: (i) comet-shaped for sinus rhythm; (ii) torpedo-shaped for sinus bradycardia; (iii) cigarette-shaped for sinus tachycardia; (iv) butterfly-shaped for sinus tachycardia and isolated atrial premature complexes; (v) arrow-shaped for isolated premature complexes and inappropriate sinus tachycardia; (vi) inverted fan-shaped for sinus rhythm with frequent atrial premature complexes; (vii) tornado-shaped for atrial flutter and atrial tachycardia; and (viii) fan-shaped for atrial fibrillation. Modified Poincaré plots with smoothed lines connecting successive points could accurately classify different types of arrhythmias based on short RR interval sequence variability. Characteristic emergent patterns can be visually identified and eventually could be distinguished by an automatic classification system able to discern between arrhythmias. This work provides an alternative method to interpret time-delay plots obtained from short-term EKG signal recordings. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  16. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  17. Combination of opium smoking and hypercholesterolemia augments susceptibility for lethal cardiac arrhythmia and atherogenesis in rabbit.

    Science.gov (United States)

    Najafipour, Hamid; Joukar, Siyavash

    2012-09-01

    Opium consumption is increasing in some eastern societies, where it is grown. We investigated the effect of opium smoking on plasma atherogenic index and incidence of lethal cardiac arrhythmia, i.e. ventricular tachycardia (VT) and ventricular fibrillation (VF) in rabbits. Animals were divided into two-, normo- and hyper-cholesterolemic main groups fed with normal or high cholesterol diet prior and during short-term and long-term exposure to opium smoke. Then, isoproterenol (3mg/kg, i.p.) was injected to induce cardiac ischemia and animals were followed for 3h for counting of lethal arrhythmia incidence. Long-term opium smoking significantly increased the plasma atherogenic index. In ischemic hearts, opium smoking along with hypercholesterolemia significantly enhanced the incidence of fatal arrhythmia. This vulnerability was not mediated by changes in QT interval. These data suggest that opium smoking, especially in hypercholesterolemic conditions, can be a predisposing factor for atherogenesis and lethal arrhythmia. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Cardiac arrhythmia with premature ventricular contractures induced by interferon beta in a patient with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Igor Sobol

    2015-03-01

    Full Text Available Multiple sclerosis (MS is an immune-mediated inflammatory and neurodegenerative disease of the central nervous system. Interferon (IFN beta is an active ingredient of five out of twelve disease modifying treatments approved for MS. We report a case of IFN-beta-induced cardiac arrhythmia with premature ventricular contractures in a patient recently diagnosed with MS.

  19. Is exposure to ionising radiation associated with childhood cardiac arrhythmia in the Russian territories contaminated by the Chernobyl fallout? A cross-sectional population-based study.

    Science.gov (United States)

    Jourdain, Jean-Rene; Landon, Geraldine; Clero, Enora; Doroshchenko, Vladimir; Silenok, Aleksandr; Kurnosova, Irina; Butsenin, Andrei; Denjoy, Isabelle; Franck, Didier; Heuze, Jean-Pierre; Gourmelon, Patrick

    2018-03-25

    To investigate childhood cardiac arrhythmia and chronic exposure to caesium-137 ( 137 Cs) resulting from the Chernobyl accident. Prospective cross-sectional study using exposed/unexposed design conducted in the Bryansk region from May 2009 to May 2013 on children selected on the basis of 137 Cs soil deposition: control territories ([ 137 Cs]555 kBq per square metre, where children were considered as exposed). Russian territories affected by the Chernobyl fallout (Bryansk region). This cross-sectional study included 18 152 children aged 2-18 years and living in the Bryansk region (Russia). All children received three medical examinations (ECG, echocardiography and 137 Cs whole-body activity measurement) and some of them were given with a 24-hour Holter monitoring and blood tests. Cardiac arrhythmia was diagnosed in 1172 children living in contaminated territories and 1354 children living in control territories. The crude prevalence estimated to 13.3% in contaminated territories was significantly lower than in control territories with 15.2% over the period 2009-2013 (PChernobyl fallout. The suspected increase of cardiac arrhythmia in children exposed to Chernobyl fallout is not confirmed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Arctigenin, a Potential Anti-Arrhythmic Agent, Inhibits Aconitine-Induced Arrhythmia by Regulating Multi-Ion Channels

    Directory of Open Access Journals (Sweden)

    Zhenying Zhao

    2013-11-01

    Full Text Available Background/Aims: Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. Methods: A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD, sodium current (INa, L-type calcium current (ICa, L and transient outward potassium current (Ito were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Results: Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90 were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited INa and ICa,L and attenuated the aconitine-increased INa and ICa,L by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Conclusions: Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, INa, ICa, L, and Ito may be multiple targets of arctigenin, leading to its antiarrhythmic effect.

  1. Comparison of two teaching methods for cardiac arrhythmia interpretation among nursing students.

    Science.gov (United States)

    Varvaroussis, Dimitrios P; Kalafati, Maria; Pliatsika, Paraskevi; Castrén, Maaret; Lott, Carsten; Xanthos, Theodoros

    2014-02-01

    The aim of this study was to compare the six-stage method (SSM) for instructing primary cardiac arrhythmias interpretation to students without basic electrocardiogram (ECG) knowledge with a descriptive teaching method in a single educational intervention. This is a randomized trial. Following a brief instructional session, undergraduate nursing students, assigned to group A (SSM) and group B (descriptive teaching method), undertook a written test in cardiac rhythm recognition, immediately after the educational intervention (initial exam). Participants were also examined with an unannounced retention test (final exam), one month after instruction. Altogether 134 students completed the study. Interpretation accuracy for each cardiac arrhythmia was assessed. Mean score at the initial exam was 8.71±1.285 for group A and 8.74±1.303 for group B. Mean score at the final exam was 8.25±1.46 for group A vs 7.84±1.44 for group B. Overall results showed that the SSM was equally effective with the descriptive teaching method. The study showed that in each group bradyarrhythmias were identified correctly by more students than tachyarrhythmias. No significant difference between the two teaching methods was seen for any specific cardiac arrhythmia. The SSM effectively develops staff competency for interpreting common cardiac arrhythmias in students without ECG knowledge. More research is needed to support this conclusion and the method's effectiveness must be evaluated if being implemented to trainee groups with preexisting basic ECG interpretation knowledge. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Cardiac Arrhythmia: Atrial Flutter in a Newborn. Case Study

    Directory of Open Access Journals (Sweden)

    T.M. Klimenko

    2014-09-01

    Full Text Available The article gives case report of rare in neonatal period cardiac arrhythmia — atrial flutter. The disease is one of the manifestations of life-threatening heart rhythm disorders, has no characteristic clinical picture, is diagnosed only by means of an electrocardiogram.

  3. [Intravenous nitroglycerin infusion suppresses exercise-induced arrhythmia in patients with ischemic cardiopathy: indications for chronic treatment ].

    Science.gov (United States)

    Bonetti, F; Margonato, A; Mailhac, A; Vicedomini, G; Cianflone, D; Scarpazza, P; Chierchia, S L

    1990-05-01

    In patients with ischemic heart disease and arrhythmias, selection of antiarrhythmic treatment is often difficult as it is hard to separate "primary" from ischemic arrhythmias. We studied 20 patients with ischemic heart disease, who developed ventricular arrhythmias consistently during exercise test. Exercise test was performed twice during infusion of placebo and then during intravenous administration of nitroglycerin, titrated to reduce systolic blood pressure by 10 mmHg. Exercise duration was 7.8 +/- 1.7 and 7.9 +/- 1.5 min, in the 2 placebo tests (NS). Angina developed in 5 patients and ischemic ST changes in 10. With nitroglycerin exercise duration increased to 8.4 +/- 20 min (p less than 0.05), diagnostic ST segment depression was observed in 2 patients and only 1 had angina. In all 20 patients, ventricular arrhythmias were consistently present during both tests on placebo, that were markedly reduced by nitroglycerin. In fact, ventricular ectopic beats were 455 (mean 35.8 +/- 16.8) and 418 (mean 34.4 +/- 11.1) in the 2 exercise tests with placebo, and 11 during nitroglycerin infusion (mean 0.6 +/- 0.1; p less than 0.001). Couplets were 28 and 29 during placebo (NS) and 0 during nitroglycerin (p less than 0.001). Ventricular tachycardia was present in 6 and 8 patients during placebo but in none during nitroglycerin (p less than 0.001). Reduction of exercise-induced arrhythmias was maintained during chronic treatment with oral vasodilators. Prevention of exercise-related arrhythmias by nitroglycerin infusion appears a good indicator of their ischemic origin and may provide valuable information for long-term profilaxis with oral vasodilators, then avoiding the use of antiarrhythmic agents and their potential side effects.

  4. Integrated photovoltaic (PV) monitoring system

    Science.gov (United States)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  5. Current and future technologies for remote monitoring in cardiology and evidence from trial data.

    Science.gov (United States)

    Acosta-Lobos, Andres; Riley, Jillian P; Cowie, Martin R

    2012-05-01

    All major manufacturers of implantable pacing or defibrillator technologies support remote monitoring of their devices. Integration of signals from several monitored variables can facilitate earlier detection of arrhythmia or technical problems, and can also identify patients at risk of deterioration. Meta-analyses of randomized studies of remote monitoring of heart failure using standalone systems suggest considerable clinical benefit when compared with usual care. However, there may be little to be gained by frequently monitoring patients with well-treated stable disease. Trials of implantable monitoring-only devices suggest that there is a subgroup of patients that may benefit from such remote monitoring. Remote monitoring is still not widely adopted due to a number of social, technological and reimbursement issues, but this is likely to change rapidly. Remote monitoring will not replace face-to-face clinical review, but it will be part of the solution to ever increasing numbers of patients with heart failure and/or an implantable device requiring expert input to their care.

  6. Validation of a real-time wireless telemedicine system, using bluetooth protocol and a mobile phone, for remote monitoring patient in medical practice.

    Science.gov (United States)

    Yousef, Jasemian; Lars, A N

    2005-06-22

    This paper validates the integration of a generic real-time wireless telemedicine system utilising Global System for Mobile Communications (GSM), BLUETOOTH protocol and General Packet Radio Service (GPRS) for cellular network in clinical practice. In the first experiment, the system was tested on 24 pacemaker patients at Aalborg Hospital (Denmark), in order to see if the pacemaker implant would be affected by the system. I the second experiment, the system was tested on 15 non risky arrhythmia heart patients, in order to evaluate and validate the system application in clinical practice, for patient monitoring. Electrocardiograms were selected as the continuously monitored parameter in the present study. The results showed that the system had no negative effects on the pacemaker implants. The experiment results showed, that in a realistic environment for the patients, the system had 96.1 % up-time, 3.2 (kbps) throughput, 10(-3) (packet/s) Packet Error Rate and 10(-3) (packet/s) Packet Lost Rate. During 24 hours test the network did not respond for 57 minutes, from which 83.1 % was in the range of 0-3 minutes, 15.4 % was in the range of 3-5 minutes, and only 0.7 % of the down-time was > or = 5 and < or = 6 minutes. By a subjective evaluation, it was demonstrated that the system is applicable and the patients as well as the healthcare personals were highly confident with the system. Moreover, the patients had high degree of mobility and freedom, employing the system. In conclusion, this generic telemedicine system showed a high reliability, quality and performance, and the design can provide a basic principle for real-time wireless remote monitoring systems used in clinical practice.

  7. Hereditary arrhythmias and cardiomyopathies: decision-making about genetic testing.

    Science.gov (United States)

    Louis, Clauden; Calamaro, Emily; Vinocur, Jeffrey M

    2018-01-01

    The modern field of clinical genetics has advanced beyond the traditional teachings familiar to most practicing cardiologists. Increased understanding of the roles of genetic testing may improve uptake and appropriateness of use. Clinical genetics has become integral to the management of patients with hereditary arrhythmia and cardiomyopathy diagnoses. Depending on the condition, genetic testing may be useful for diagnosis, prognosis, treatment, family screening, and reproductive planning. However, genetic testing is a powerful tool with potential for underuse, overuse, and misuse. In the absence of a substantial body of literature on how these guidelines are applied in clinical practice, we use a case-based approach to highlight key lessons and pitfalls. Importantly, in many scenarios genetic testing has become the standard of care supported by numerous class I recommendations; genetic counselors can improve accessibility to and appropriate use and application of testing. Optimal management of hereditary arrhythmias and cardiomyopathies incorporates genetic testing, applied as per consensus guidelines, with involvement of a multidisciplinary team.

  8. Arctigenin, a potential anti-arrhythmic agent, inhibits aconitine-induced arrhythmia by regulating multi-ion channels.

    Science.gov (United States)

    Zhao, Zhenying; Yin, Yongqiang; Wu, Hong; Jiang, Min; Lou, Jianshi; Bai, Gang; Luo, Guo'an

    2013-01-01

    Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD), sodium current (I(Na)), L-type calcium current (I(Ca, L)) and transient outward potassium current (I(to)) were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90) were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited I(Na) and I(Ca,L) and attenuated the aconitine-increased I(Na) and I(Ca,L) by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, I(Na), I(Ca, L), and I(to) may be multiple targets of arctigenin, leading to its antiarrhythmic effect. © 2013 S. Karger AG, Basel.

  9. Possible influence of the polarity reversal of the solar magnetic field on the various types of arrhythmias

    International Nuclear Information System (INIS)

    Giannaropoulou, E; Papailiou, M; Mavromichalaki, H; Preka-Papadema, P; Gigolashvili, M; Tvildiani, L; Janashia, K; Papadima, Th

    2013-01-01

    Over the last few years various researches have reached the conclusion that cosmic ray variations and geomagnetic disturbances are related to the condition of the human physiological state. In this study medical data concerning the number of incidents of different types of cardiac arrhythmias for the time period 1983 – 1992 which refer to 1902 patients in Tbilisi, Georgia were used. The smoothing method and the Pearson r-coefficients were used to examine the possible effect of different solar and geomagnetic activity parameters and cosmic ray intensity variations on the different types of arrhythmias. The time interval under examination was separated into two different time periods which coincided with the polarity reversal of the solar magnetic field that occurred in the years 1989-1990 and as a result a different behavior of all the above mentioned parameters as well as of the different types of arrhythmias was noticed during the two time intervals. In addition, changing of polarity sign of the solar magnetic field was found to affect the sign of correlation between the incidence of arrhythmias and the aforementioned parameters. The primary and secondary maxima observed in the solar parameters during the solar cycle 22, also appeared in several types of arrhythmias with a time lag of about five months.

  10. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  11. Percutaneous cardiopulmonary support for catheter ablation of unstable ventricular arrhythmias in high-risk patients.

    Science.gov (United States)

    Carbucicchio, Corrado; Della Bella, Paolo; Fassini, Gaetano; Trevisi, Nicola; Riva, Stefania; Giraldi, Francesco; Baratto, Francesca; Marenzi, Giancarlo; Sisillo, Erminio; Bartorelli, Antonio; Alamanni, Francesco

    2009-11-01

    In patients with severe cardiomyopathy, recurrent episodes of nontolerated ventricular tachycardia (VT) or electrical storm (ES) frequently cause acute heart failure and cardiac death; the suppression of the arrhythmia is therefore lifesaving, but feasibility of catheter ablation (CA) is precluded by the adverse hemodynamic conditions together with the characteristics of the arrhythmia that interdicts efficacious mapping. The use of the percutaneous cardiopulmonary support (CPS) for circulatory assistance may allow patient's stabilization and enhance efficacy and safety of CA in this emergency setting. 19 patients (19 males; mean age 61 +/- 6 years; chronic ischemic cardiomyopathy, eleven patients; primary dilated cardiomyopathy, six patients; arrhythmogenic right ventricular dysplasia/ cardiomyopathy, two patients) with recurrent nontolerated VT episodes undergoing CPS-assisted CA were retrospectively evaluated. Twelve patients had acute hemodynamic failure refractory to inotropic agents and ventilatory assistance, seven patients had undergone a failing nonconventional CA procedure. 14 patients presented with ES, and in twelve the procedure was undertaken under emergency conditions within 24 h from admission. Patients were ventilated under general anesthesia and assisted by a multidisciplinary team. The CPS system consisted in a Medtronic Bio-Medicus centrifugal pump and in a Maxima Plus oxygenator, a 15-F arterial cannula, and a 17-F venous cannula. Flows between 2 and 3 l/min were activated after induction of 56/62 forms of nontolerated VT, achieving hemodynamic stabilization in all patients. CA was mainly guided by conventional activation mapping and was effective in abolishing 45/56 supported VTs; in 10/19 patients all clinical VTs were suppressed by CA. Mean procedural time was 4 h and 20 min. Complete stabilization was achieved in 13 patients (68%) without VT recurrence during a 7-day in-hospital monitoring. A significant clinical improvement was observed in

  12. Facilitating arrhythmia simulation: the method of quantitative cellular automata modeling and parallel running

    Directory of Open Access Journals (Sweden)

    Mondry Adrian

    2004-08-01

    Full Text Available Abstract Background Many arrhythmias are triggered by abnormal electrical activity at the ionic channel and cell level, and then evolve spatio-temporally within the heart. To understand arrhythmias better and to diagnose them more precisely by their ECG waveforms, a whole-heart model is required to explore the association between the massively parallel activities at the channel/cell level and the integrative electrophysiological phenomena at organ level. Methods We have developed a method to build large-scale electrophysiological models by using extended cellular automata, and to run such models on a cluster of shared memory machines. We describe here the method, including the extension of a language-based cellular automaton to implement quantitative computing, the building of a whole-heart model with Visible Human Project data, the parallelization of the model on a cluster of shared memory computers with OpenMP and MPI hybrid programming, and a simulation algorithm that links cellular activity with the ECG. Results We demonstrate that electrical activities at channel, cell, and organ levels can be traced and captured conveniently in our extended cellular automaton system. Examples of some ECG waveforms simulated with a 2-D slice are given to support the ECG simulation algorithm. A performance evaluation of the 3-D model on a four-node cluster is also given. Conclusions Quantitative multicellular modeling with extended cellular automata is a highly efficient and widely applicable method to weave experimental data at different levels into computational models. This process can be used to investigate complex and collective biological activities that can be described neither by their governing differentiation equations nor by discrete parallel computation. Transparent cluster computing is a convenient and effective method to make time-consuming simulation feasible. Arrhythmias, as a typical case, can be effectively simulated with the methods

  13. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  14. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  15. Unique Association of Rare Cardiovascular Disease in an Athlete With Ventricular Arrhythmias.

    Science.gov (United States)

    Santomauro, V; Contursi, M; Dellegrottaglie, S; Borsellino, G

    2015-01-01

    Ventricular arrhythmias are a leading cause of non-elegibility to competitive sport. The failure to detect a significant organic substrate in the initial stage of screening does not preclude the identification of structural pathologies in the follow-up by using advanced imaging techniques. Here we report the case of a senior athlete judged not elegible because an arrhythmia with the morphology consistent with the origin of the left ventricle, in which subsequent execution of a cardiac MR and a thoracic CT scan has allowed the identification of an unique association between an area of myocardial damage, probable site of origine of the arrhythma, and a rare aortic malformation.

  16. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    Science.gov (United States)

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  17. Acute effects of sex steroid hormones on susceptibility to cardiac arrhythmias: a simulation study.

    Directory of Open Access Journals (Sweden)

    Pei-Chi Yang

    2010-01-01

    Full Text Available Acute effects of sex steroid hormones likely contribute to the observation that post-pubescent males have shorter QT intervals than females. However, the specific role for hormones in modulating cardiac electrophysiological parameters and arrhythmia vulnerability is unclear. Here we use a computational modeling approach to incorporate experimentally measured effects of physiological concentrations of testosterone, estrogen and progesterone on cardiac ion channel targets. We then study the hormone effects on ventricular cell and tissue dynamics comprised of Faber-Rudy computational models. The "female" model predicts changes in action potential duration (APD at different stages of the menstrual cycle that are consistent with clinically observed QT interval fluctuations. The "male" model predicts shortening of APD and QT interval at physiological testosterone concentrations. The model suggests increased susceptibility to drug-induced arrhythmia when estradiol levels are high, while testosterone and progesterone are apparently protective. Simulations predict the effects of sex steroid hormones on clinically observed QT intervals and reveal mechanisms of estrogen-mediated susceptibility to prolongation of QT interval. The simulations also indicate that acute effects of estrogen are not alone sufficient to cause arrhythmia triggers and explain the increased risk of females to Torsades de Pointes. Our results suggest that acute effects of sex steroid hormones on cardiac ion channels are sufficient to account for some aspects of gender specific susceptibility to long-QT linked arrhythmias.

  18. Design of a hybrid model for cardiac arrhythmia classification based on Daubechies wavelet transform.

    Science.gov (United States)

    Rajagopal, Rekha; Ranganathan, Vidhyapriya

    2018-06-05

    Automation in cardiac arrhythmia classification helps medical professionals make accurate decisions about the patient's health. The aim of this work was to design a hybrid classification model to classify cardiac arrhythmias. The design phase of the classification model comprises the following stages: preprocessing of the cardiac signal by eliminating detail coefficients that contain noise, feature extraction through Daubechies wavelet transform, and arrhythmia classification using a collaborative decision from the K nearest neighbor classifier (KNN) and a support vector machine (SVM). The proposed model is able to classify 5 arrhythmia classes as per the ANSI/AAMI EC57: 1998 classification standard. Level 1 of the proposed model involves classification using the KNN and the classifier is trained with examples from all classes. Level 2 involves classification using an SVM and is trained specifically to classify overlapped classes. The final classification of a test heartbeat pertaining to a particular class is done using the proposed KNN/SVM hybrid model. The experimental results demonstrated that the average sensitivity of the proposed model was 92.56%, the average specificity 99.35%, the average positive predictive value 98.13%, the average F-score 94.5%, and the average accuracy 99.78%. The results obtained using the proposed model were compared with the results of discriminant, tree, and KNN classifiers. The proposed model is able to achieve a high classification accuracy.

  19. Perinatal management and long-term cardiac outcome in fetal arrhythmia

    NARCIS (Netherlands)

    Hahurij, N.D.; Blom, N.A.; Lopriore, E.; Aziz, M.I.; Nagel, H.T.; Rozendaal, L.; Vandenbussche, F.P.H.A.

    2011-01-01

    BACKGROUND: cardiac arrhythmias are commonly observed in the fetus, however, may have major consequences for fetal development and post natal life. AIMS: to evaluate the perinatal management and cardiac outcome of fetuses with tachy- or bradyarrhythmia. STUDY DESIGN: perinatal management, outcome

  20. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  1. Arctigenin, a Potential Anti-Arrhythmic Agent, Inhibits Aconitine-Induced Arrhythmia by Regulating Multi-Ion Channels

    OpenAIRE

    Zhenying Zhao; Yongqiang Yin; Hong Wu; Min Jiang; Jianshi Lou; Gang Bai; Guo‘an Luo

    2013-01-01

    Background/Aims: Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. Methods: A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were reco...

  2. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  3. Ultrasound diagnosis and monitoring of fetal tachyarrhythmias

    Directory of Open Access Journals (Sweden)

    Yu.А. Ivaniv

    2017-12-01

    Full Text Available The aim – to evaluate the efficiency of prenatal echocardiography in detecting, differential diagnosis and monitoring fetuses with tachyarrhythmias. Materials and methods. Investigations performed in a single center from April 1996 to July 2016 were analysed. During this study 2,073 pregnant women were examined and 213 cases of fetal arrhythmia were found (10.3 %. Prenatal echocardiography was conducted by general protocol, each examination were fixed and saved in electronic and paper form. Results. During this period 25 cases of fetal tachyarrhythmias were diagnosed, representing 11.7 % of all cases of arrhythmia and 1.2 % of all fetal heart examinations. In five fetuses tachyarrhythmia was combined with structural heart disorders, which constitutes 20 % among all tachyarrhythmias. Most fetal tachyarrhythmias (21 were diagnosed during third trimester of pregnancy. The most common fetal tachyarrhythmia was atrioventricular «re-entry» tachycardia – 14 cases (56 %. None case of this group was combined with structural cardiac pathology, however, almost half were accompanied by hemodynamic complications. Drug treatment was effective in this group. Atrial fibrillation was second prevalent in our study, 4 cases (16 % – dangerous arrhythmia, which in most fetuses caused circulatory failure, being combined with congenital heart defect or myocardial pathology. Drug treatment in this group is less effective, depending on comorbidity and age pregnancy. We diagnosed 4 cases of sinus tachycardia (16 %, largely having benign course in the prenatal period and not requiring drug treatment. Prognosis of pregnancy is determined by concomitant diseases of the fetus. One case (4 % of atrial flutter required preterm delivery through the hemodynamic complications. Ectopic atrial tachycardia was diagnosed in two fetuses (8 %. This arrhythmia is insensitive to medical treatment and may persist after birth. Conclusions. Clinical management of pregnancy, the need

  4. Noninvasive risk stratification of lethal ventricular arrhythmias and sudden cardiac death after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Kenji Yodogawa, MD

    2014-08-01

    Full Text Available Prediction of lethal ventricular arrhythmias leading to sudden cardiac death is one of the most important and challenging problems after myocardial infarction (MI. Identification of MI patients who are prone to ventricular tachyarrhythmias allows for an indication of implantable cardioverter-defibrillator placement. To date, noninvasive techniques such as microvolt T-wave alternans (MTWA, signal-averaged electrocardiography (SAECG, heart rate variability (HRV, and heart rate turbulence (HRT have been developed for this purpose. MTWA is an indicator of repolarization abnormality and is currently the most promising risk-stratification tool for predicting malignant ventricular arrhythmias. Similarly, late potentials detected by SAECG are indices of depolarization abnormality and are useful in risk stratification. However, the role of SAECG is limited because of its low predictive accuracy. Abnormal HRV and HRT patterns reflect autonomic disturbances, which may increase the risk of lethal ventricular arrhythmias, but the existing evidence is insufficient. Further studies of noninvasive assessment may provide a new insight into risk stratification in post-MI patients.

  5. TECRL, a new life-threatening inherited arrhythmia gene associated with overlapping clinical features of both LQTS and CPVT

    NARCIS (Netherlands)

    Devalla, Harsha D.; Gélinas, Roselle; Aburawi, Elhadi H.; Beqqali, Abdelaziz; Goyette, Philippe; Freund, Christian; Chaix, Marie-A.; Tadros, Rafik; Jiang, Hui; Le Béchec, Antony; Monshouwer-Kloots, Jantine J.; Zwetsloot, Tom; Kosmidis, Georgios; Latour, Frédéric; Alikashani, Azadeh; Hoekstra, Maaike; Schlaepfer, Jurg; Mummery, Christine L.; Stevenson, Brian; Kutalik, Zoltan; de Vries, Antoine Af; Rivard, Léna; Wilde, Arthur Am; Talajic, Mario; Verkerk, Arie O.; Al-Gazali, Lihadh; Rioux, John D.; Bhuiyan, Zahurul A.; Passier, Robert

    2016-01-01

    Genetic causes of many familial arrhythmia syndromes remain elusive. In this study, whole-exome sequencing (WES) was carried out on patients from three different families that presented with life-threatening arrhythmias and high risk of sudden cardiac death (SCD). Two French Canadian probands

  6. Production of arrhythmias by elevated carboxyhemoglobin in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Sheps, D.S.; Herbst, M.C.; Hinderliter, A.L.; Adams, K.F.; Ekelund, L.G.; O'Neil, J.J.; Goldstein, G.M.; Bromberg, P.A.; Dalton, J.L.; Ballenger, M.N.

    1990-01-01

    The object of this study was to assess the effects of exposure to 4% and 6% carboxyhemoglobin on ventricular arrhythmias in patients with coronary artery disease. This was a randomized, double-blind, crossover design. Forty-one nonsmokers with documented coronary artery disease were tested. On day 1, a training session with no exposure, the baseline carboxyhemoglobin level was measured, and a supine bicycle exercise test was done. On days 2 to 4, patients were exposed to room air, 100 ppm carbon monoxide (target, 4% carboxyhemoglobin) or 200 ppm carbon monoxide (target, 6% carboxyhemoglobin), and they then did supine bicycle exercise with radionuclide ventriculography. Ambulatory electrocardiogram recordings were made during the 4 consecutive days to determine the frequency of ventricular premature depolarization (VPD) at various intervals. The frequency of single VPD/h was significantly greater on the 6% carboxyhemoglobin day than on the room air day during the exercise period (167.72 +/- 37.99 for 6% carboxyhemoglobin compared with 127.32 +/- 28.22 for room air, P = 0.03). During exercise, the frequency of multiple VPD/h was greater on the 6% carboxyhemoglobin day compared with room air (9.59 +/- 3.70 on the 6% carboxyhemoglobin compared with 3.18 +/- 1.67 on room air, P = 0.02). Patients who developed increased single VPD during exercise on the 6% carboxyhemoglobin day were significantly older than those who had no increased arrhythmia, whereas patients who developed complex arrhythmias were also older and, in addition, exercised longer and had a higher peak workload during exercise. The number and complexity of ventricular arrhythmias increases significantly during exercise after carbon monoxide exposure producing 6% carboxyhemoglobin compared with room air but not after exposure producing 4% carboxyhemoglobin

  7. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  8. Mortality of Inherited Arrhythmia Syndromes Insight Into Their Natural History

    NARCIS (Netherlands)

    Nannenberg, Eline A.; Sijbrands, Eric J. G.; Dijksman, Lea M.; Alders, Marielle; van Tintelen, J. Peter; Birnie, Martijn; van Langen, Irene M.; Wilde, Arthur A. M.

    Background-For most arrhythmia syndromes, the risk of sudden cardiac death for asymptomatic mutation carriers is ill defined. Data on the natural history of these diseases, therefore, are essential. The family tree mortality ratio method offers the unique possibility to study the natural history at

  9. Mobile Cardiac Health-care Monitoring and Notification with Real Time Tachycardia and Bradycardia Arrhythmia Detection.

    Science.gov (United States)

    Golzar, Mina; Fotouhi-Ghazvini, Faranak; Rabbani, Hossein; Zakeri, Fahimeh Sadat

    2017-01-01

    The increasing trend of heart disease has turned the attention of researchers toward the use of portable connected technologies. The necessity of continuous special care for cardiovascular patients is an inevitable fact. In this research, a new wireless electrocardiographic (ECG) signal-monitoring system based on smartphone is presented. This system has two main sections. The first section consists of a sensor which receives ECG signals via an amplifier, then filters and digitizes the signal, and prepares it to be transmitted. The signals are stored, processed, and then displayed in a mobile application. The application alarms in dangerous situations and sends the location of the cardiac patient to family or health-care staff. The results obtained from the analysis of the electrocardiogram signals on 20 different people have been compared with the traditional ECG in hospital by a cardiologist. The signal is instantly transmitted by 200 sample per second to mobile phone. The raw data are processed, the anomaly is detected, and the signal is drawn on the interface in about 70 s. Therefore, the delay is not noticeable by the patient. With respect to rate of data transmission to hospital, different internet connections such as 2G, 3G, 4G, WiFi, WiMax, or Long-Term Evolution (LTE) could be used. Data transmission ranges from 9.6 kbps to 20 Mbps. Therefore, the physician could receive data with no delay. A performance accuracy of 91.62% is obtained from the wireless ECG system. It conforms to the hospital's diagnostic standard system while providing a portable monitoring anywhere at anytime.

  10. Particulate Air Pollution, Ambulatory Heart Rate Variability, and Cardiac Arrhythmia in Retirement Community Residents with Coronary Artery Disease

    Science.gov (United States)

    Longhurst, John; Tjoa, Thomas; Sioutas, Constantinos; Delfino, Ralph J.

    2013-01-01

    Background: Decreased heart rate variability (HRV) has been associated with future cardiac morbidity and mortality and is often used as a marker of altered cardiac autonomic balance in studies of health effects of airborne particulate matter. Fewer studies have evaluated associations between air pollutants and cardiac arrhythmia. Objectives: We examined relationships between cardiac arrhythmias, HRV, and exposures to airborne particulate matter. Methods: We measured HRV and arrhythmia with ambulatory electrocardiograms in a cohort panel study for up to 235 hr per participant among 50 nonsmokers with coronary artery disease who were ≥ 71 years of age and living in four retirement communities in the Los Angeles, California, Air Basin. Exposures included hourly outdoor gases, hourly traffic-related and secondary organic aerosol markers, and daily size-fractionated particle mass. We used repeated measures analyses, adjusting for actigraph-derived physical activity and heart rate, temperature, day of week, season, and community location. Results: Ventricular tachycardia was significantly increased in association with increases in markers of traffic-related particles, secondary organic carbon, and ozone. Few consistent associations were observed for supraventricular tachycardia. Particulates were significantly associated with decreased ambulatory HRV only in the 20 participants using ACE (angiotensin I–converting enzyme) inhibitors. Conclusions: Although these data support the hypothesis that particulate exposures may increase the risk of ventricular tachycardia for elderly people with coronary artery disease, HRV was not associated with exposure in most of our participants. These results are consistent with previous findings in this cohort for systemic inflammation, blood pressure, and ST segment depression. Citation: Bartell SM, Longhurst J, Tjoa T, Sioutas C, Delfino RJ. 2013. Particulate air pollution, ambulatory heart rate variability, and cardiac arrhythmia in

  11. An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects.

    Science.gov (United States)

    Kim, Jinkwon; Min, Se Dong; Lee, Myoungho

    2011-06-27

    Numerous studies have been conducted regarding a heartbeat classification algorithm over the past several decades. However, many algorithms have also been studied to acquire robust performance, as biosignals have a large amount of variation among individuals. Various methods have been proposed to reduce the differences coming from personal characteristics, but these expand the differences caused by arrhythmia. In this paper, an arrhythmia classification algorithm using a dedicated wavelet adapted to individual subjects is proposed. We reduced the performance variation using dedicated wavelets, as in the ECG morphologies of the subjects. The proposed algorithm utilizes morphological filtering and a continuous wavelet transform with a dedicated wavelet. A principal component analysis and linear discriminant analysis were utilized to compress the morphological data transformed by the dedicated wavelets. An extreme learning machine was used as a classifier in the proposed algorithm. A performance evaluation was conducted with the MIT-BIH arrhythmia database. The results showed a high sensitivity of 97.51%, specificity of 85.07%, accuracy of 97.94%, and a positive predictive value of 97.26%. The proposed algorithm achieves better accuracy than other state-of-the-art algorithms with no intrasubject between the training and evaluation datasets. And it significantly reduces the amount of intervention needed by physicians.

  12. An arrhythmia classification algorithm using a dedicated wavelet adapted to different subjects

    Directory of Open Access Journals (Sweden)

    Min Se Dong

    2011-06-01

    Full Text Available Abstract Background Numerous studies have been conducted regarding a heartbeat classification algorithm over the past several decades. However, many algorithms have also been studied to acquire robust performance, as biosignals have a large amount of variation among individuals. Various methods have been proposed to reduce the differences coming from personal characteristics, but these expand the differences caused by arrhythmia. Methods In this paper, an arrhythmia classification algorithm using a dedicated wavelet adapted to individual subjects is proposed. We reduced the performance variation using dedicated wavelets, as in the ECG morphologies of the subjects. The proposed algorithm utilizes morphological filtering and a continuous wavelet transform with a dedicated wavelet. A principal component analysis and linear discriminant analysis were utilized to compress the morphological data transformed by the dedicated wavelets. An extreme learning machine was used as a classifier in the proposed algorithm. Results A performance evaluation was conducted with the MIT-BIH arrhythmia database. The results showed a high sensitivity of 97.51%, specificity of 85.07%, accuracy of 97.94%, and a positive predictive value of 97.26%. Conclusions The proposed algorithm achieves better accuracy than other state-of-the-art algorithms with no intrasubject between the training and evaluation datasets. And it significantly reduces the amount of intervention needed by physicians.

  13. Environmental monitoring and information systems

    International Nuclear Information System (INIS)

    Gibbert, R.

    1998-01-01

    Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)

  14. Data monitoring system of technical diagnosis system for EAST

    International Nuclear Information System (INIS)

    Qian Jing; Weng Peide; Chen Zhuomin; Wu Yu; Xi Weibin; Luo Jiarong

    2010-01-01

    Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor.. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described. (authors)

  15. The JOYO remote monitoring system

    International Nuclear Information System (INIS)

    Damico, Joseph P.; Hashimoto, Yu

    2000-01-01

    The evolution of the personal computer, operating systems and applications software and the Internet has brought drastic change and many benefits worldwide. Remote monitoring systems benefit from computer network and other modern software technologies. The availability of fast, inexpensive and secure communications enables new solutions for monitoring system applications. The JOYO Remote Monitoring System (RMS) utilizes computer network communications and modular software design to provide a distributed integrated solution for monitoring multiple storage locations. This paper describes the remote monitoring system installed at the JOYO Fast Reactor. The system combines sensors, software, and computer network technologies to create a powerful data collection, storage and dissemination capability. The RMS provides a flexible, scalable solution for a variety of applications. The RMS integrates a variety of state of the art technologies from several sources and serves as a test bed for cutting edge technologies that can be shared with outside users. This paper describes the system components and their operation and discusses system benefits. Current activities and future plants for the JOYO RMS will be discussed. (author)

  16. Unattended Monitoring System Design Methodology

    International Nuclear Information System (INIS)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-01-01

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations

  17. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  18. Chewing reduces sympathetic nervous response to stress and prevents poststress arrhythmias in rats.

    Science.gov (United States)

    Koizumi, So; Minamisawa, Susumu; Sasaguri, Kenichi; Onozuka, Minoru; Sato, Sadao; Ono, Yumie

    2011-10-01

    Reducing stress is important in preventing sudden death in patients with cardiovascular disease, as stressful events may cause autonomic imbalance and trigger fatal arrhythmias. Since chewing has been shown to inhibit stress-induced neuronal responses in the hypothalamus, we hypothesized that chewing could ameliorate stress-induced autonomic imbalance and prevent arrhythmias. To test this hypothesis, we analyzed changes in radiotelemetered electrocardiograms in rats that were allowed to chew a wooden stick during a 1-h period of immobilization stress. Chewing significantly reduced the occurrence of ventricular premature beats (VPBs) and complex ventricular ectopy after immobilization and prevented stress-induced prolongation of the QT interval of VPBs throughout the 10-h experimental period. It also prevented prolongation of the QRS complex and fluctuations in the QT interval in normal sinus rhythm beats preceding VPBs during both immobilization and in the poststress period. Fast Fourier transform-based spectral analysis of heart-rate variability further showed that chewing significantly inhibited the stress-induced increase in the power ratio of low-to-high frequency activity (LF/HF: a marker of sympathetic activity) during immobilization and in addition was associated with blunting of the stress-induced increase in plasma noradrenaline observed at the termination of immobilization. Similar suppressive effects on the occurrence of VPBs and the LF/HF were observed in rats that were administered the β-adrenergic blocker propranolol before immobilization. These results indicate that chewing can ameliorate sympathetic hyperactivity during stress and prevent poststress arrhythmias and suggest that chewing may provide a nonpharmacological and cost-effective treatment option for patients with a high risk of stress-induced fatal arrhythmia.

  19. The impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot.

    Science.gov (United States)

    Ávila, Pablo; Marcotte, François; Dore, Annie; Mercier, Lise-Andrée; Shohoudi, Azadeh; Mongeon, François-Pierre; Mondésert, Blandine; Proietti, Anna; Ibrahim, Reda; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2016-09-15

    Sudden death of presumed arrhythmic etiology is the leading cause of mortality in adults with tetralogy of Fallot. To assess the impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot. Adults with repaired tetralogy of Fallot were randomized in a 2:1 ratio to an open-label trial of standard care versus 12weeks of supervised combined aerobic/resistance training with continuous Holter monitoring. Proportion of premature ventricular complexes (PVC) and runs of non-sustained ventricular tachycardia (NSVT) were assessed by mixed and Poisson regression models with generalized estimating equations for repeated measures. A total of 152 Holters were performed in 17 patients, median age 35 (interquartile range [IQR] 28, 42) years, 65% male, 13 of whom were randomized to exercise training. Baseline characteristics were similar between groups. Exercise training resulted in significant increases in peak oxygen uptake (11±19%, p=0.028), metabolic equivalents (11±18%, p=0.027), and exercise duration (8±10%, p=0.009) compared to no changes in controls. Frequent (≥30 per hour) PVCs were present in 46% of patients, couplets in 62%, and 3 to 7 beat runs of NSVT in 31%. The median proportion of PVCs was 1.93‰ (IQR 0.41, 5.89) at baseline and 1.45‰ (IQR 0.08, 2.76) during the initial exercise session (p=0.722), and remained stable over time (ß coefficient=-0.031, p=0.408). Runs of NSVT decreased significantly over time (ß coefficient=-0.032, p=0.018). In adults with repaired tetralogy of Fallot, exercise training is safe, improves exercise capacity, and appears to confer a beneficial effect on ventricular arrhythmias. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  1. Use of whole exome sequencing for the identification of Ito-based arrhythmia mechanism and therapy.

    Science.gov (United States)

    Sturm, Amy C; Kline, Crystal F; Glynn, Patric; Johnson, Benjamin L; Curran, Jerry; Kilic, Ahmet; Higgins, Robert S D; Binkley, Philip F; Janssen, Paul M L; Weiss, Raul; Raman, Subha V; Fowler, Steven J; Priori, Silvia G; Hund, Thomas J; Carnes, Cynthia A; Mohler, Peter J

    2015-05-26

    Identified genetic variants are insufficient to explain all cases of inherited arrhythmia. We tested whether the integration of whole exome sequencing with well-established clinical, translational, and basic science platforms could provide rapid and novel insight into human arrhythmia pathophysiology and disease treatment. We report a proband with recurrent ventricular fibrillation, resistant to standard therapeutic interventions. Using whole-exome sequencing, we identified a variant in a previously unidentified exon of the dipeptidyl aminopeptidase-like protein-6 (DPP6) gene. This variant is the first identified coding mutation in DPP6 and augments cardiac repolarizing current (Ito) causing pathological changes in Ito and action potential morphology. We designed a therapeutic regimen incorporating dalfampridine to target Ito. Dalfampridine, approved for multiple sclerosis, normalized the ECG and reduced arrhythmia burden in the proband by >90-fold. This was combined with cilostazol to accelerate the heart rate to minimize the reverse-rate dependence of augmented Ito. We describe a novel arrhythmia mechanism and therapeutic approach to ameliorate the disease. Specifically, we identify the first coding variant of DPP6 in human ventricular fibrillation. These findings illustrate the power of genetic approaches for the elucidation and treatment of disease when carefully integrated with clinical and basic/translational research teams. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Frequency of cardiac arrhythmias in high and low- yielding dairy cows

    Directory of Open Access Journals (Sweden)

    Afshin Jafari Dehkordi

    2014-06-01

    Full Text Available Electrocardiography (ECG may be used to recognize cardiac disorders. Levels of milk production may change the serum electrolytes which its imbalance has a role in cardiac arrhythmia. Fifty high yielding and fifty low yielding Holstein dairy cows were used in this study. Electrocardiography was recorded by base-apex lead and blood samples were collected from jugular vein for measurement of serum elements such as sodium, potassium, calcium, phosphorous, iron and magnesium. Cardiac dysrhythmias were detected more frequent in low yielding Holstein cows (62.00% compared to high yielding Holstein cows (46.00%. The cardiac dysrhythmias that were observed in low yielding Holstein cows included sinus arrhythmia (34.70%, wandering pacemaker (22.45 %, bradycardia (18.37%, tachycardia (10.20%, atrial premature beat (2.04%, sinoatrial block (2.04%, atrial fibrillation (8.16% and atrial tachycardia (2.04%. The cardiac dysrhythmias were observed in high yielding Holstein cows including, sinus arrhythmia (86.95% and wandering pacemaker (13.05%. Also, notched P wave was observed to be 30% and 14% in high- and low- yielding Holstein cows respectively. The serum calcium concentration of low yielding Holstein cows was significantly lower than that of high yielding Holstein cows. There was not any detectable significant difference in other serum elements between high- and low- yielding Holstein cows. Based on the result of present study, could be concluded that low serum concentration of calcium results to more frequent dysrhythmias in low yielding Holstein cows.

  3. High-throughput cardiac safety evaluation and multi-parameter arrhythmia profiling of cardiomyocytes using microelectrode arrays

    Energy Technology Data Exchange (ETDEWEB)

    Gilchrist, Kristin H., E-mail: kgilchrist@rti.org; Lewis, Gregory F.; Gay, Elaine A.; Sellgren, Katelyn L.; Grego, Sonia

    2015-10-15

    Microelectrode arrays (MEAs) recording extracellular field potentials of human-induced pluripotent stem cell-derived cardiomyocytes (hiPS-CM) provide a rich data set for functional assessment of drug response. The aim of this work is the development of a method for a systematic analysis of arrhythmia using MEAs, with emphasis on the development of six parameters accounting for different types of cardiomyocyte signal irregularities. We describe a software approach to carry out such analysis automatically including generation of a heat map that enables quick visualization of arrhythmic liability of compounds. We also implemented signal processing techniques for reliable extraction of the repolarization peak for field potential duration (FPD) measurement even from recordings with low signal to noise ratios. We measured hiPS-CM's on a 48 well MEA system with 5 minute recordings at multiple time points (0.5, 1, 2 and 4 h) after drug exposure. We evaluated concentration responses for seven compounds with a combination of hERG, QT and clinical proarrhythmia properties: Verapamil, Ranolazine, Flecainide, Amiodarone, Ouabain, Cisapride, and Terfenadine. The predictive utility of MEA parameters as surrogates of these clinical effects were examined. The beat rate and FPD results exhibited good correlations with previous MEA studies in stem cell derived cardiomyocytes and clinical data. The six-parameter arrhythmia assessment exhibited excellent predictive agreement with the known arrhythmogenic potential of the tested compounds, and holds promise as a new method to predict arrhythmic liability. - Highlights: • Six parameters describing arrhythmia were defined and measured for known compounds. • Software for efficient parameter extraction from large MEA data sets was developed. • The proposed cellular parameter set is predictive of clinical drug proarrhythmia.

  4. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  5. The Role of Biologically Active Ingredients from Natural Drug Treatments for Arrhythmias in Different Mechanisms

    OpenAIRE

    Li, Jie; Hu, Dan; Song, Xiaoli; Han, Tao; Gao, Yonghong; Xing, Yanwei

    2017-01-01

    Arrhythmia is a disease that is caused by abnormal electrical activity in the heart rate or rhythm. It is the major cause of cardiovascular morbidity and mortality. Although several antiarrhythmic drugs have been used in clinic for decades, their application is often limited by their adverse effects. As a result, natural drugs, which have fewer side effects, are now being used to treat arrhythmias. We searched for all articles on the role of biologically active ingredients from natural drug t...

  6. Single-Nucleotide Variations in Cardiac Arrhythmias: Prospects for Genomics and Proteomics Based Biomarker Discovery and Diagnostics

    Directory of Open Access Journals (Sweden)

    Ayman Abunimer

    2014-03-01

    Full Text Available Cardiovascular diseases are a large contributor to causes of early death in developed countries. Some of these conditions, such as sudden cardiac death and atrial fibrillation, stem from arrhythmias—a spectrum of conditions with abnormal electrical activity in the heart. Genome-wide association studies can identify single nucleotide variations (SNVs that may predispose individuals to developing acquired forms of arrhythmias. Through manual curation of published genome-wide association studies, we have collected a comprehensive list of 75 SNVs associated with cardiac arrhythmias. Ten of the SNVs result in amino acid changes and can be used in proteomic-based detection methods. In an effort to identify additional non-synonymous mutations that affect the proteome, we analyzed the post-translational modification S-nitrosylation, which is known to affect cardiac arrhythmias. We identified loss of seven known S-nitrosylation sites due to non-synonymous single nucleotide variations (nsSNVs. For predicted nitrosylation sites we found 1429 proteins where the sites are modified due to nsSNV. Analysis of the predicted S-nitrosylation dataset for over- or under-representation (compared to the complete human proteome of pathways and functional elements shows significant statistical over-representation of the blood coagulation pathway. Gene Ontology (GO analysis displays statistically over-represented terms related to muscle contraction, receptor activity, motor activity, cystoskeleton components, and microtubule activity. Through the genomic and proteomic context of SNVs and S-nitrosylation sites presented in this study, researchers can look for variation that can predispose individuals to cardiac arrhythmias. Such attempts to elucidate mechanisms of arrhythmia thereby add yet another useful parameter in predicting susceptibility for cardiac diseases.

  7. Cardiac arrhythmia beat classification using DOST and PSO tuned SVM.

    Science.gov (United States)

    Raj, Sandeep; Ray, Kailash Chandra; Shankar, Om

    2016-11-01

    The increase in the number of deaths due to cardiovascular diseases (CVDs) has gained significant attention from the study of electrocardiogram (ECG) signals. These ECG signals are studied by the experienced cardiologist for accurate and proper diagnosis, but it becomes difficult and time-consuming for long-term recordings. Various signal processing techniques are studied to analyze the ECG signal, but they bear limitations due to the non-stationary behavior of ECG signals. Hence, this study aims to improve the classification accuracy rate and provide an automated diagnostic solution for the detection of cardiac arrhythmias. The proposed methodology consists of four stages, i.e. filtering, R-peak detection, feature extraction and classification stages. In this study, Wavelet based approach is used to filter the raw ECG signal, whereas Pan-Tompkins algorithm is used for detecting the R-peak inside the ECG signal. In the feature extraction stage, discrete orthogonal Stockwell transform (DOST) approach is presented for an efficient time-frequency representation (i.e. morphological descriptors) of a time domain signal and retains the absolute phase information to distinguish the various non-stationary behavior ECG signals. Moreover, these morphological descriptors are further reduced in lower dimensional space by using principal component analysis and combined with the dynamic features (i.e based on RR-interval of the ECG signals) of the input signal. This combination of two different kinds of descriptors represents each feature set of an input signal that is utilized for classification into subsequent categories by employing PSO tuned support vector machines (SVM). The proposed methodology is validated on the baseline MIT-BIH arrhythmia database and evaluated under two assessment schemes, yielding an improved overall accuracy of 99.18% for sixteen classes in the category-based and 89.10% for five classes (mapped according to AAMI standard) in the patient

  8. At-admission risk stratification for in-hospital life-threatening ventricular arrhythmias and death in non-ST elevation myocardial infarction patients.

    Science.gov (United States)

    Zorzi, Alessandro; Turri, Riccardo; Zilio, Filippo; Spadotto, Veronica; Baritussio, Anna; Peruzza, Francesco; Gasparetto, Nicola; Marra, Martina Perazzolo; Cacciavillani, Luisa; Marzari, Armando; Tarantini, Giuseppe; Iliceto, Sabino; Corrado, Domenico

    2014-12-01

    Identification of patients with non-ST elevation acute myocardial infarction (NSTEMI) at higher risk of in-hospital life-threatening ventricular arrhythmias (LT-VA) and death is crucial for determining appropriate levels of care/monitoring during hospitalisation. We assessed predictors of in-hospital LT-VA and all-cause mortality in a consecutive series of NSTEMI patients. We prospectively studied 1325 consecutive patients (69.7% males, median age 70 (61-79) years) presenting with NSTEMI and undergoing continuous electrocardiographic monitoring. The primary study end-point was the occurrence of spontaneous (unrelated to coronary interventions) in-hospital LT-VA, including sustained ventricular tachycardia and ventricular fibrillation; the secondary end-point was in-hospital mortality from all causes. Of 1325 patients, 21 (1.5%) experienced LT-VA and 62 (4.7%) died from either arrhythmias (n=1) or other causes (n=61). Seven of the 20 patients who survived LT-VA subsequently died of heart failure. Independent predictors of in-hospital LT-VA were the Global Registry of Acute Coronary Events (GRACE) score >140 (odds ratio (OR)=7.5; 95% confidence interval (CI) 1.7-33.3; p=0.008) and left ventricular ejection fraction (LV-EF)140 (OR=14.6; 95% CI 3.4-62) and LV-EF 140 and LV-EF<35%, while it was respectively 0.2% and 0% among the 627 (47.3%) with GRACE score ≤140 and LV-EF ≥35%. Simple risk stratification at admission based on GRACE score and echocardiographic LV-EF allows early identification of NSTEMI patients at higher risk of both in-hospital LT-VA and all-cause mortality. © The European Society of Cardiology 2014.

  9. System health monitoring

    International Nuclear Information System (INIS)

    Reneke, J.A.; Fryer, M.O.

    1995-01-01

    Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection

  10. chronic sleep deprevation and ventricular arrhythmias: effect of symphatic nervous system

    Directory of Open Access Journals (Sweden)

    Samira Choopani

    2016-04-01

    Full Text Available Introduction: We assessed the effect of chronic sleep deprivation on incidence of ischemia/reperfusion-induced ventricular arrhythmias (ventricular tachycardia and ventricular fibrillation and the role of the sympathetic nervous system in this respect. Material and methods: Rats were randomly divided into four groups; 1 ischemia/reperfusion group (IR: 30 minutes ischemia followed by 60 minutes reperfusion was induced, 2 control group (CON: rats has been placed in large multiple platforms for 72h prior to ischemia and reperfusion, 3 Chronic sleep deprivation group( SD: 72h sleep deprivation was induced by using small  multiple platform prior to ischemia and reperfusion, 4 Sympathectomy group (SYM: chemical sympathectomy was done 24h before to chronic sleep deprivation and then underwent ischemia and reperfusion. The heart isolated and perfused by langendorff apparatus. After thoracotomy and aorta cannulation, the hearts perfused in the langendorff apparatus using krebs-Henseleit buffer. Hearts were allowed to recovery for 15 min. After recovery period, 15 minutes was considered as baseline prior to 30 minutes ischemia followed by 60 minutes reperfusion.Tow thin stainless stell electrodes fixed on the ventricular apex and right atrium for recording the lead II of electrocardiogram (ECG.Results: There were no significant differences between heart rates between groups, and ventricular tachycardia significantly increased in chronic sleep deprivation group As compared with IR group in ischemia period. Sympathectomy significantly reduced ventricular tachycardia incidence when compared with SD. There is no difference in incidence of ventricular tachycardia between control group and IR group. The incidence of ventricular fibrillation during early reperfusion was significantly augmented (P<0.05 in sleep deprivation group as compared with IR group and Sympathectomy significantly could reverse ventricular fibrillation incidence to IR group level as

  11. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  12. Maintenance of radiation monitoring systems

    International Nuclear Information System (INIS)

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  13. Relationship of serum magnesium level and supplemental magnesium dosage with post coronary artery bypass graft surgery arrhythmias

    Directory of Open Access Journals (Sweden)

    Najafi M

    2007-06-01

    Full Text Available Background: Atrial and ventricular arrhythmias are among the most common complications after coronary artery bypass graft (CABG surgery. Previous studies demonstrated that cardiopulmonary bypass itself results in reduced serum magnesium levels. In this study, we evaluated the effect of total blood magnesium level (TMG on the prevention of perioperative arrhythmias with routine regimens of 2-4 grams supplemental magnesium (SMG. Methods: TMG was measured in patients who were scheduled for CABG on three occasions: just before anesthesia, just after entering the intensive care unit (ICU after completion of the sugery, and on the first morning after the operation. Patients were evaluated for primary cardiac rhythm and other variables that could have an influence on the magnesium level, including serum creatinine, urine output in the operating room and diuretic therapy. The SMG dosage was also recorded in the operating room and ICU. Patients were then evaluated for the rate and type of arrhythmia for the next three days. Results: The mean TMG levels in 174 cases were 2.2 (0.5, 2.6 (0.6 and 2.4 (0.6 mg/dl for the three occasions, respectively. The mean SMG was 2.5 (1.2 grams. Of 164 patients, 51 (31% developed the following post-operative arrhythmias: AF (7.3%, non-AF SVA (15.2% and ventricular (16.5%. The mean serum creatinine level and urine output were 1.2 mg/dl and 1800 ml, respectively. Although there was a significant difference between the TMG levels on the three different occasions (P<0.001, all values were within normal range. When we stratified the TMG levels of the patients based on administered SMG, the Mentel-Haenszel test revealed no significant difference between the first and third TMG (P=0.6. Although the TMG levels were higher in arrhythmic patients compared to those without arrhythmia (2.25 vs. 2.14 mg/dl, both values were within the normal range and there was no significant difference between the two groups. Serum creatinine levels

  14. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  15. Classification of ECG signal with Support Vector Machine Method for Arrhythmia Detection

    Science.gov (United States)

    Turnip, Arjon; Ilham Rizqywan, M.; Kusumandari, Dwi E.; Turnip, Mardi; Sihombing, Poltak

    2018-03-01

    An electrocardiogram is a potential bioelectric record that occurs as a result of cardiac activity. QRS Detection with zero crossing calculation is one method that can precisely determine peak R of QRS wave as part of arrhythmia detection. In this paper, two experimental scheme (2 minutes duration with different activities: relaxed and, typing) were conducted. From the two experiments it were obtained: accuracy, sensitivity, and positive predictivity about 100% each for the first experiment and about 79%, 93%, 83% for the second experiment, respectively. Furthermore, the feature set of MIT-BIH arrhythmia using the support vector machine (SVM) method on the WEKA software is evaluated. By combining the available attributes on the WEKA algorithm, the result is constant since all classes of SVM goes to the normal class with average 88.49% accuracy.

  16. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  17. The effect of intermittent fasting and water restriction on myocardial ischemia/reperfusion-induced arrhythmia in rats

    OpenAIRE

    KAYA, Salih Tunç; BOZDOĞAN, Ömer

    2011-01-01

    To investigate the effect of intermittent fasting and water restriction on ischemia/reperfusion-induced arrhythmias. Materials and methods: Six minutes of ischemia followed by 6 min of reperfusion was produced by the ligation and then releasing of the left coronary artery. Intermittent fasting and water restriction were applied during 1 month for 12 h/day. The duration, type, and incidence of arrhythmias during reperfusion and the survival rate at the end of reperfusion were determined and c...

  18. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  19. LiteNet: Lightweight Neural Network for Detecting Arrhythmias at Resource-Constrained Mobile Devices

    Directory of Open Access Journals (Sweden)

    Ziyang He

    2018-04-01

    Full Text Available By running applications and services closer to the user, edge processing provides many advantages, such as short response time and reduced network traffic. Deep-learning based algorithms provide significantly better performances than traditional algorithms in many fields but demand more resources, such as higher computational power and more memory. Hence, designing deep learning algorithms that are more suitable for resource-constrained mobile devices is vital. In this paper, we build a lightweight neural network, termed LiteNet which uses a deep learning algorithm design to diagnose arrhythmias, as an example to show how we design deep learning schemes for resource-constrained mobile devices. Compare to other deep learning models with an equivalent accuracy, LiteNet has several advantages. It requires less memory, incurs lower computational cost, and is more feasible for deployment on resource-constrained mobile devices. It can be trained faster than other neural network algorithms and requires less communication across different processing units during distributed training. It uses filters of heterogeneous size in a convolutional layer, which contributes to the generation of various feature maps. The algorithm was tested using the MIT-BIH electrocardiogram (ECG arrhythmia database; the results showed that LiteNet outperforms comparable schemes in diagnosing arrhythmias, and in its feasibility for use at the mobile devices.

  20. Obesity and exercise-induced ectopic ventricular arrhythmias in apparently healthy middle aged adults.

    Science.gov (United States)

    Sabbag, Avi; Sidi, Yechezkel; Kivity, Shaye; Beinart, Roy; Glikson, Michael; Segev, Shlomo; Goldenberg, Ilan; Maor, Elad

    2016-03-01

    Obesity and overweight are strongly associated with cardiovascular morbidity and mortality. However, there are limited data on the association between excess weight and the risk of ectopic ventricular activity. We investigated the association between body mass index (BMI) and the risk for ectopic ventricular activity (defined as multiple ventricular premature beats (≥3), ventricular bigeminy, nonsustained ventricular tachycardia or sustained ventricular tachycardia) during exercise stress testing among 22,516 apparently healthy men and women who attended periodic health screening examinations between the years 2000 and 2014. All subjects had completed maximal exercise stress testing annually according to the Bruce protocol. Subjects were divided at baseline into three groups: normal weight (BMI ≥ 18.5 kg/m(2) andexercise-induced ectopic ventricular activity arrhythmias was highest among obese subjects, intermediate among overweight subjects and lowest among subjects with normal weight (3.4%, 2.7% and 2.2% respectively; p exercise compared with subjects with normal weight (p = 0.005), and that each 1 kg/m(2) increase in BMI was associated with a significant 4% (p = 0.002) increased adjusted risk for exercise-induced ventricular arrhythmias. Obesity is independently associated with increased likelihood of ectopic ventricular arrhythmia during exercise. © The European Society of Cardiology 2015.

  1. LiteNet: Lightweight Neural Network for Detecting Arrhythmias at Resource-Constrained Mobile Devices.

    Science.gov (United States)

    He, Ziyang; Zhang, Xiaoqing; Cao, Yangjie; Liu, Zhi; Zhang, Bo; Wang, Xiaoyan

    2018-04-17

    By running applications and services closer to the user, edge processing provides many advantages, such as short response time and reduced network traffic. Deep-learning based algorithms provide significantly better performances than traditional algorithms in many fields but demand more resources, such as higher computational power and more memory. Hence, designing deep learning algorithms that are more suitable for resource-constrained mobile devices is vital. In this paper, we build a lightweight neural network, termed LiteNet which uses a deep learning algorithm design to diagnose arrhythmias, as an example to show how we design deep learning schemes for resource-constrained mobile devices. Compare to other deep learning models with an equivalent accuracy, LiteNet has several advantages. It requires less memory, incurs lower computational cost, and is more feasible for deployment on resource-constrained mobile devices. It can be trained faster than other neural network algorithms and requires less communication across different processing units during distributed training. It uses filters of heterogeneous size in a convolutional layer, which contributes to the generation of various feature maps. The algorithm was tested using the MIT-BIH electrocardiogram (ECG) arrhythmia database; the results showed that LiteNet outperforms comparable schemes in diagnosing arrhythmias, and in its feasibility for use at the mobile devices.

  2. Dispersion of repolarization and refractoriness are determinants of arrhythmia phenotype in transgenic mice with long QT.

    Science.gov (United States)

    London, Barry; Baker, Linda C; Petkova-Kirova, Polina; Nerbonne, Jeanne M; Choi, Bum-Rak; Salama, Guy

    2007-01-01

    Enhanced dispersion of repolarization (DR) and refractoriness may be a unifying mechanism central to arrhythmia genesis in the long QT (LQT) syndrome. The role of DR in promoting arrhythmias was investigated in several strains of molecularly engineered mice: (a) Kv4.2 dominant negative transgenic (Kv4.2DN) that lacks the fast component of the transient outward current, I(to,f), have action potential (AP) and QT prolongation, but no spontaneous arrhythmias, (b) Kv1.4 targeted mice (Kv1.4-/-) that lack the slow component of I(to) (I(to,s)), have no QT prolongation and no spontaneous arrhythmias, and (c) double transgenic (Kv4.2DN x Kv1.4-/-) mice that lack both I(to,f) and I(to,s), have AP and QT prolongation, and spontaneous ventricular tachyarrhythmias. Hearts were perfused, stained with di-4-ANEPPS and optically mapped. Activation patterns and conduction velocities were similar between the strains but AP duration at 75% recovery (APD75) was longer in Kv4.2DN (28.0 +/- 2.5 ms, P mice than controls (20.3 +/- 1.0 ms, n = 5). Dispersion of refractoriness between apex and base was markedly reduced in Kv4.2DN (0.3 +/- 0.5 ms, n = 6, P mice compared with controls (10 +/- 2 ms, n = 5). A premature pulse elicited ventricular tachycardia (VT) in Kv1.4-/- (n = 4/5) and Kv4.2DN x Kv1.4-/- hearts (n = 5/5) but not Kv4.2DN hearts (n = 0/6). Voltage-clamp recordings showed that I(to,f) was 30% greater in myocytes from the apex than base which may account for the absence of DR in Kv4.2DN mice. Thus, dispersion of repolarization (DR) appears to be an important determinant of arrhythmia vulnerability.

  3. An extended family suddenly confronted with a life-threatening hereditary arrhythmia

    NARCIS (Netherlands)

    Hendriks, K.S.W.H.; Van Langen, I.M.; Van Tintelen, J.P.; Grosfeld, F.J.M.; Wilde, A.A.M.; Ten Kroode, H.F.J.

    2005-01-01

    Objective. This exploratory study serves to illustrate the psychological impact on an extended family in the process of genetic counselling and testing for a potentially life-threatening arrhythmia, the long-QT syndrome (LQTS). Method. All members of the third generation and their partners (n=11)

  4. Cardiovascular exercise and burden of arrhythmia in patients with atrial fibrillation

    DEFF Research Database (Denmark)

    Skielboe, Ane Katrine; Bandholm, Thomas Quaade; Hakmann, Stine

    2017-01-01

    BACKGROUND: Physical activity at moderate-high intensity is recommended to prevent lifestyle diseases. Patients with atrial fibrillation are at risk of a sedentary lifestyle due to fear of exercise-induced episodes of atrial fibrillation. The burden of arrhythmia can be reduced by physical exercise...

  5. Computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  6. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  7. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  8. Coolant monitoring systems for PWR reactors

    International Nuclear Information System (INIS)

    Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.

    1987-01-01

    The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated

  9. Monitoring of Danish marketed solar heating systems

    International Nuclear Information System (INIS)

    Ellehauge, K.

    1993-01-01

    The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)

  10. Radiation monitor system for nuclear power plants

    International Nuclear Information System (INIS)

    Wu Bingzhe; Guo Shusheng

    1990-12-01

    The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants

  11. An extended family suddenly confronted with a life-threatening hereditary arrhythmia

    NARCIS (Netherlands)

    Hendriks, K. S. W. H.; van Langen, I. M.; van Tintelen, J. P.; Grosfeld, F. J. M.; Wilde, A. A. M.; ten Kroode, H. F. J.

    2005-01-01

    This exploratory study serves to illustrate the psychological impact on an extended family in the process of genetic counselling and testing for a potentially life-threatening arrhythmia, the long-QT syndrome (LQTS). All members of the third generation and their partners (n=11) were interviewed, the

  12. N-3 fatty acids from fish and markers of cardiac arrhythmia

    NARCIS (Netherlands)

    Geelen, A.

    2004-01-01

    N‑3 fatty acids from fish may protect against heart disease mortality by preventing fatal arrhythmias. The objective of this thesis was to investigate whether this possible antiarrhythmic effect of n-3 fatty acids is supported by short-term effects on electrophysiological markers. We performed two

  13. The Role of Biologically Active Ingredients from Natural Drug Treatments for Arrhythmias in Different Mechanisms.

    Science.gov (United States)

    Li, Jie; Hu, Dan; Song, Xiaoli; Han, Tao; Gao, Yonghong; Xing, Yanwei

    2017-01-01

    Arrhythmia is a disease that is caused by abnormal electrical activity in the heart rate or rhythm. It is the major cause of cardiovascular morbidity and mortality. Although several antiarrhythmic drugs have been used in clinic for decades, their application is often limited by their adverse effects. As a result, natural drugs, which have fewer side effects, are now being used to treat arrhythmias. We searched for all articles on the role of biologically active ingredients from natural drug treatments for arrhythmias in different mechanisms in PubMed. This study reviews 19 natural drug therapies, with 18 active ingredient therapies, such as alkaloids, flavonoids, saponins, quinones, and terpenes, and two kinds of traditional Chinese medicine compound (Wenxin-Keli and Shensongyangxin), all of which have been studied and reported as having antiarrhythmic effects. The primary focus is the proposed antiarrhythmic mechanism of each natural drug agent. Conclusion . We stress persistent vigilance on the part of the provider in discussing the use of natural drug agents to provide a solid theoretical foundation for further research on antiarrhythmia drugs.

  14. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  15. A Grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin [Fermi National Accelerator Laboratory (United States); Nowack, Andreas [RWTH Aachen (Germany); Padhi, Sanjay [University of California San Diego (United States); Sarkar, Subir, E-mail: subir.sarkar@cern.c [INFN, Sezione di Pisa and Scuola Normale Superiore, Pisa (Italy)

    2010-04-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  16. A grid job monitoring system

    International Nuclear Information System (INIS)

    Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  17. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  18. Ion Channel Trafficking: Control of Ion Channel Density as a Target for Arrhythmias?

    Directory of Open Access Journals (Sweden)

    Elise Balse

    2017-10-01

    Full Text Available The shape of the cardiac action potential (AP is determined by the contributions of numerous ion channels. Any dysfunction in the proper function or expression of these ion channels can result in a change in effective refractory period (ERP and lead to arrhythmia. The processes underlying the correct targeting of ion channels to the plasma membrane are complex, and have not been fully characterized in cardiac myocytes. Emerging evidence highlights ion channel trafficking as a potential causative factor in certain acquired and inherited arrhythmias, and therapies which target trafficking as opposed to pore block are starting to receive attention. In this review we present the current evidence for the mechanisms which underlie precise control of cardiac ion channel trafficking and targeting.

  19. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  20. Family and population strategies for screening and counselling of inherited cardiac arrhythmias

    NARCIS (Netherlands)

    Van Langen, I.M.; Hofman, N.; Tan, H.L.; Wilde, A.A.M.

    2004-01-01

    Family screening in inherited cardiac arrhythmias has been performed in The Netherlands since 1996, when diagnostic DNA testing in long QT syndrome (LOTS) and hypertrophic cardiomyopathy (HCM) became technically possible. In multidisciplinary outpatient academic clinics, an adjusted protocol for

  1. Distributed Monitoring System Based on ICINGA

    CERN Multimedia

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  2. GTA Beamloss-Monitor System

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper

  3. GTA beamloss-monitor system

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamloss-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamloss-Monitor System measures the induced gamma radiation, from (p,γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals, integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamloss-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics, is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/93 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper. (Author) 4 figs., ref

  4. AV-block and conduction slowing prevail over TdP arrhythmias in the methoxamine-sensitized pro-arrhythmic rabbit model.

    Science.gov (United States)

    Varkevisser, Rosanne; Vos, Marc A; Beekman, Jet D; Tieland, Ralph G; Van Der Heyden, Marcel A

    2015-01-01

    The methoxamine-sensitized rabbit model is widely used to screen drugs for proarrhythmic properties, especially repolarization-dependent TdP arrhythmias. With the change of anesthesia and/or sensitizing agent, conduction disturbances have been reported as well. Therefore, we compared currently available in-house anesthetics in order to preserve arrhythmia sensitivity and preclude conduction disturbances. Rabbits were randomly assigned to 3 groups: (1) 35 mg/kg ketamine + 5 mg/kg xylazine; (2) 0.5 mL/kg hypnorm + 3 mg/kg midazolam; (3) 35 mg/kg ketamine + 20 mg/kg propofol. Anesthesia was maintained by 1.5% isoflurane. Concomitant infusion of methoxamine (17 μg/kg/min for 40 minutes) and dofetilide (10 μg/kg/min for 30 minutes) was used to induce arrhythmias. Sole methoxamine infusion exclusively decreased HR in groups 1 and 3. Dofetilide lengthened repolarization, followed in time by PQ/QRS prolongation, second-degree AV block, and subsequently TdP arrhythmias. TdP was seen in 80%, 0%, and 33% of the rabbits in groups 1, 2, and 3, respectively. Decreasing the dose of dofetilide to 5 μg/kg/min in ketamine/xylazine anesthetized rabbits resulted in a drop in TdP incidence (25%) while conduction disturbances persisted. Flunarizine (n = 6) suppressed all TdP arrhythmias while conduction disturbances remained present. TdP incidence in the methoxamine-sensitized rabbit could be dramatically influenced by anesthesia, drug dose, and flunarizine, while conduction slowing remained present. Thus, conduction slowing seems to be the integral outcome in this model. © 2014 Wiley Periodicals, Inc.

  5. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  6. Association of ventricular arrhythmia and in-hospital mortality in stroke patients in Florida: A nonconcurrent prospective study.

    Science.gov (United States)

    Dahlin, Arielle A; Parsons, Chase C; Barengo, Noël C; Ruiz, Juan Gabriel; Ward-Peterson, Melissa; Zevallos, Juan Carlos

    2017-07-01

    Stroke remains one of the leading causes of death in the United States. Current evidence identified electrocardiographic abnormalities and cardiac arrhythmias in 50% of patients with an acute stroke. The purpose of this study was to assess whether the presence of ventricular arrhythmia (VA) in adult patients hospitalized in Florida with acute stroke increased the risk of in-hospital mortality.Secondary data analysis of 215,150 patients with ischemic and hemorrhagic stroke hospitalized in the state of Florida collected by the Florida Agency for Healthcare Administration from 2008 to 2012. The main outcome for this study was in-hospital mortality. The main exposure of this study was defined as the presence of VA. VA included the ICD-9 CM codes: paroxysmal ventricular tachycardia (427.1), ventricular fibrillation (427.41), ventricular flutter (427.42), ventricular fibrillation and flutter (427.4), and other - includes premature ventricular beats, contractions, or systoles (427.69). Differences in demographic and clinical characteristics and hospital outcomes were assessed between patients who developed versus did not develop VA during hospitalization (χ and t tests). Binary logistic regression was used to estimate unadjusted and adjusted odds ratios and 95% confidence intervals (CIs) between VA and in-hospital mortality.VA was associated with an increased risk of in-hospital mortality after adjusting for all covariates (odds ratio [OR]: 1.75; 95% CI: 1.6-1.2). There was an increased in-hospital mortality in women compared to men (OR: 1.1; 95% CI: 1.1-1.14), age greater than 85 years (OR: 3.9, 95% CI: 3.5-4.3), African Americans compared to Whites (OR: 1.1; 95% CI: 1.04-1.2), diagnosis of congestive heart failure (OR: 2.1; 95% CI: 2.0-2.3), and atrial arrhythmias (OR: 2.1, 95% CI: 2.0-2.2). Patients with hemorrhagic stroke had increased odds of in-hospital mortality (OR: 9.0; 95% CI: 8.6-9.4) compared to ischemic stroke.Identifying VAs in stroke patients may help in

  7. Low-complexity R-peak detection in ECG signals: a preliminary step towards ambulatory fetal monitoring.

    Science.gov (United States)

    Rooijakkers, Michiel; Rabotti, Chiara; Bennebroek, Martijn; van Meerbergen, Jef; Mischi, Massimo

    2011-01-01

    Non-invasive fetal health monitoring during pregnancy has become increasingly important. Recent advances in signal processing technology have enabled fetal monitoring during pregnancy, using abdominal ECG recordings. Ubiquitous ambulatory monitoring for continuous fetal health measurement is however still unfeasible due to the computational complexity of noise robust solutions. In this paper an ECG R-peak detection algorithm for ambulatory R-peak detection is proposed, as part of a fetal ECG detection algorithm. The proposed algorithm is optimized to reduce computational complexity, while increasing the R-peak detection quality compared to existing R-peak detection schemes. Validation of the algorithm is performed on two manually annotated datasets, the MIT/BIH Arrhythmia database and an in-house abdominal database. Both R-peak detection quality and computational complexity are compared to state-of-the-art algorithms as described in the literature. With a detection error rate of 0.22% and 0.12% on the MIT/BIH Arrhythmia and in-house databases, respectively, the quality of the proposed algorithm is comparable to the best state-of-the-art algorithms, at a reduced computational complexity.

  8. System specification for the integrated monitoring and surveillance system

    International Nuclear Information System (INIS)

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides

  9. Dictionary-based monitoring of premature ventricular contractions: An ultra-low-cost point-of-care service.

    Science.gov (United States)

    Bollepalli, S Chandra; Challa, S Sastry; Anumandla, Laxminarayana; Jana, Soumya

    2018-04-25

    While cardiovascular diseases (CVDs) are prevalent across economic strata, the economically disadvantaged population is disproportionately affected due to the high cost of traditional CVD management, involving consultations, testing and monitoring at medical facilities. Accordingly, developing an ultra-low-cost alternative, affordable even to groups at the bottom of the economic pyramid, has emerged as a societal imperative. Against this backdrop, we propose an inexpensive yet accurate home-based electrocardiogram (ECG) monitoring service. Specifically, we seek to provide point-of-care monitoring of premature ventricular contractions (PVCs), high frequency of which could indicate the onset of potentially fatal arrhythmia. Note that the first-generation telecardiology system acquires the ECG, transmits it to a professional diagnostic center without processing, and nearly achieves the diagnostic accuracy of a bedside setup. In the process, such a system incurs high bandwidth cost and requires the physicians to process the entire record for diagnosis. To reduce cost, current telecardiology systems compress data before transmitting. However, the burden on physicians remains undiminished. In this context, we develop a dictionary-based algorithm that reduces not only the overall bandwidth requirement, but also the physicians workload by localizing anomalous beats. Specifically, we detect anomalous beats with high sensitivity and only those beats are then transmitted. In fact, we further compress those beats using class-specific dictionaries subject to suitable reconstruction/diagnostic fidelity. Finally, using Monte Carlo cross validation on MIT/BIH arrhythmia database, we evaluate the performance of the proposed system. In particular, with a sensitivity target of at most one undetected PVC in one hundred beats, and a percentage root mean squared difference less than 9% (a clinically acceptable level of fidelity), we achieved about 99.15% reduction in bandwidth cost

  10. Prevalence of Fibromyalgia Syndrome and Its Correlations with Arrhythmia in Patients with Palpitations

    Directory of Open Access Journals (Sweden)

    Ayhan Aşkın

    2018-04-01

    Full Text Available Objective: It is aimed to determine the prevalence of fibromyalgia syndrome (FMS and its correlations with arrhythmia in patients with palpitations. Material and Methods: Sixty-two patients who underwent electrophysiological study (EPS due to palpitation complaints in Cardiology department and 40 healthy controls were included in the study. The precise diagnosis of arrhythmia was established using EPS. All participants were screened for FMS using American College of Rheumatology 2010 Fibromyalgia diagnostic criteria. Clinical assessments included measurement of severity of pain, fatigue and morning fatigue with visual analog scale (VAS, functional status with Fibromyalgia Impact Questionnaire (FIQ, and anxiety/depression with Hospital Anxiety and Depression Scale (HAD. Results: FMS was diagnosed in 22 of the 62 patients (36%, and 4 of the 40 healthy controls (10% (p 0.05. EPS+ patients with FMS had higher fatigue levels, HAD and FIQ scores than EPS− patients, although statistically insignificant. HV durations were statistically longer in the EPS− subgroup (p < 0.05 but other EPS data were similar. Conclusion: FMS frequency and HAD anxiety scores were found to be higher in patients with palpitation complaints. However, we found no association between arrhythmia, EPS parameters and FMS. In our clinical practice we should keep in mind to carry out assessments in terms of FMS in patients with palpitation.

  11. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  12. Reduction of false arrhythmia alarms using signal selection and machine learning

    NARCIS (Netherlands)

    Eerikäinen, L.M.; Vanschoren, J.; Rooijakkers, M.J.; Vullings, R.; Aarts, R.M.

    2016-01-01

    In this paper, we propose an algorithm that classifies whether a generated cardiac arrhythmia alarm is true or false. The large number of false alarms in intensive care is a severe issue. The noise peaks caused by alarms can be high and in a noisy environment nurses can experience stress and

  13. High level of oxygen treatment causes cardiotoxicity with arrhythmias and redox modulation

    Energy Technology Data Exchange (ETDEWEB)

    Chapalamadugu, Kalyan C.; Panguluri, Siva K. [Department of Pharmaceutical Sciences, College of Pharmacy, University of South Florida, Tampa, FL (United States); Bennett, Eric S. [Department of Molecular Pharmacology and Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL (United States); Kolliputi, Narasaiah [Division of Allergy and Immunology, Department of Internal Medicine, Morsani College of Medicine, University of South Florida, Tampa, FL (United States); Tipparaju, Srinivas M., E-mail: stippara@health.usf.edu [Department of Pharmaceutical Sciences, College of Pharmacy, University of South Florida, Tampa, FL (United States)

    2015-01-01

    Hyperoxia exposure in mice leads to cardiac hypertrophy and voltage-gated potassium (Kv) channel remodeling. Because redox balance of pyridine nucleotides affects Kv function and hyperoxia alters cellular redox potential, we hypothesized that hyperoxia exposure leads to cardiac ion channel disturbances and redox changes resulting in arrhythmias. In the present study, we investigated the electrical changes and redox abnormalities caused by 72 h hyperoxia treatment in mice. Cardiac repolarization changes were assessed by acquiring electrocardiogram (ECG) and cardiac action potentials (AP). Biochemical assays were employed to identify the pyridine nucleotide changes, Kv1.5 expression and myocardial injury. Hyperoxia treatment caused marked bradycardia, arrhythmia and significantly prolonged (ms) the, RR (186.2 ± 10.7 vs. 146.4 ± 6.2), PR (46.8 ± 3.1 vs. 39.3 ± 1.6), QRS (10.8 ± 0.6 vs. 8.5 ± 0.2), QTc (57.1 ± 3.5 vs. 40 ± 1.4) and JT (13.4 ± 2.1 vs. 7.0 ± 0.5) intervals, when compared with normoxia group. Hyperoxia treatment also induced significant increase in cardiac action potential duration (APD) (ex-APD{sub 90}; 73.8 ± 9.5 vs. 50.9 ± 3.1 ms) and elevated levels of serum markers of myocardial injury; cardiac troponin I (TnI) and lactate dehydrogenase (LDH). Hyperoxia exposure altered cardiac levels of mRNA/protein expression of; Kv1.5, Kvβ subunits and SiRT1, and increased ratios of reduced pyridine nucleotides (NADH/NAD and NADPH/NADP). Inhibition of SiRT1 in H9C2 cells using Splitomicin resulted in decreased SiRT1 and Kv1.5 expression, suggesting that SiRT1 may mediate Kv1.5 downregulation. In conclusion, the cardiotoxic effects of hyperoxia exposure involve ion channel disturbances and redox changes resulting in arrhythmias. - Highlights: • Hyperoxia treatment leads to arrhythmia with prolonged QTc and action potential duration. • Hyperoxia treatment alters cardiac pyridine nucleotide [NAD(P)H/NAD(P)] levels. • SiRT1 and Kv1.5 are co

  14. High level of oxygen treatment causes cardiotoxicity with arrhythmias and redox modulation

    International Nuclear Information System (INIS)

    Chapalamadugu, Kalyan C.; Panguluri, Siva K.; Bennett, Eric S.; Kolliputi, Narasaiah; Tipparaju, Srinivas M.

    2015-01-01

    Hyperoxia exposure in mice leads to cardiac hypertrophy and voltage-gated potassium (Kv) channel remodeling. Because redox balance of pyridine nucleotides affects Kv function and hyperoxia alters cellular redox potential, we hypothesized that hyperoxia exposure leads to cardiac ion channel disturbances and redox changes resulting in arrhythmias. In the present study, we investigated the electrical changes and redox abnormalities caused by 72 h hyperoxia treatment in mice. Cardiac repolarization changes were assessed by acquiring electrocardiogram (ECG) and cardiac action potentials (AP). Biochemical assays were employed to identify the pyridine nucleotide changes, Kv1.5 expression and myocardial injury. Hyperoxia treatment caused marked bradycardia, arrhythmia and significantly prolonged (ms) the, RR (186.2 ± 10.7 vs. 146.4 ± 6.2), PR (46.8 ± 3.1 vs. 39.3 ± 1.6), QRS (10.8 ± 0.6 vs. 8.5 ± 0.2), QTc (57.1 ± 3.5 vs. 40 ± 1.4) and JT (13.4 ± 2.1 vs. 7.0 ± 0.5) intervals, when compared with normoxia group. Hyperoxia treatment also induced significant increase in cardiac action potential duration (APD) (ex-APD 90 ; 73.8 ± 9.5 vs. 50.9 ± 3.1 ms) and elevated levels of serum markers of myocardial injury; cardiac troponin I (TnI) and lactate dehydrogenase (LDH). Hyperoxia exposure altered cardiac levels of mRNA/protein expression of; Kv1.5, Kvβ subunits and SiRT1, and increased ratios of reduced pyridine nucleotides (NADH/NAD and NADPH/NADP). Inhibition of SiRT1 in H9C2 cells using Splitomicin resulted in decreased SiRT1 and Kv1.5 expression, suggesting that SiRT1 may mediate Kv1.5 downregulation. In conclusion, the cardiotoxic effects of hyperoxia exposure involve ion channel disturbances and redox changes resulting in arrhythmias. - Highlights: • Hyperoxia treatment leads to arrhythmia with prolonged QTc and action potential duration. • Hyperoxia treatment alters cardiac pyridine nucleotide [NAD(P)H/NAD(P)] levels. • SiRT1 and Kv1.5 are co-regulated in

  15. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  16. Energy Doubler cryoloop temperature monitor system

    International Nuclear Information System (INIS)

    Pucci, G.; Howard, D.

    1981-10-01

    The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control

  17. A multicenter, long-term study on arrhythmias in children with Ebstein anomaly.

    NARCIS (Netherlands)

    Delhaas, T.; Sarvaas, G.J.; Rijlaarsdam, M.E.; Strengers, J.L.; Eveleigh, R.M.; Poulino, S.E.; Korte, C.L. de; Kapusta, L.

    2010-01-01

    To assess the prevalence, history, and treatment of arrhythmias, in particular preexcitation and Wolff-Parkinson-White (WPW) syndrome, in patients with Ebstein anomaly (EA) during childhood and adolescence, we performed a multicenter retrospective study of all consecutive live-born patients with EA,

  18. A Multicenter, Long-Term Study on Arrhythmias in Children with Ebstein Anomaly

    NARCIS (Netherlands)

    Delhaas, Tammo; Sarvaas, Gideon J. du Marchie; Rijlaarsdam, Marry E.; Strengers, Jan L.; Eveleigh, Rhona M.; Poulino, Sumayah E.; de Korte, Chris L.; Kapusta, Livia

    To assess the prevalence, history, and treatment of arrhythmias, in particular preexcitation and Wolff-Parkinson-White (WPW) syndrome, in patients with Ebstein anomaly (EA) during childhood and adolescence, we performed a multicenter retrospective study of all consecutive live-born patients with EA,

  19. Hanger-type laundry monitor system

    International Nuclear Information System (INIS)

    Aoyama, Kei; Kouno, Yoshio; Yanagishima, Ryouhei; Ikeda, Yasuyuki; Nakatani, Masahiro

    1987-01-01

    Laundry monitor is installed in nuclear power plants or other nuclear facilities in order to efficiently detect radioactive contamination remains on the surfaces of the working clothes which were used in the controlled area and washed afterward. The number of the working clothes which must be measured has been increasing in accordance with the increase of the nuclear facilities. This fact and recent intensified radiation control require automatic, high-speed and high sensitive measurement. Conveyer-type laundry monitor in which the working clothes are inserted by the metal net conveyer has been generally used, and recently new system with an automatic folder has become more popular. But, this type of system has not so big capacity because the clothes are conveyed longitudinally and also requires considerable wide space when installed. Fuji electric Co., Ltd. has been engaging in research and development for an optimum laundry monitor system used in nuclear facilities since the joint investigation with ten electric power companies in Japan in 1982. Consequently hanger-type laundry monitor system using automatic hanger conveyer was developed and 2 systems were delivered to Chubu Electric Power Co., Ltd. in 1986. This system permits to detect radioactive contamination on the working clothes, pick the contaminated clothes out and fold the uncontaminated clothes fully automatically and continuously. Moreover it allows to shorten the measurement time because the clothes are conveyed transversely and save the installation space, so that this will be regarded as considerably complete system in the world. This report describes the outline of the hanger-type laundry monitor system. (author)

  20. Storage monitoring systems for the year 2000

    International Nuclear Information System (INIS)

    Nilsen, C.; Pollock, R.

    1997-01-01

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000

  1. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  2. [Treatment of arrhythmia in coronary patients and hypertensives with beta blockers and Depasan retard].

    Science.gov (United States)

    Kandziora, J

    1981-05-14

    In the ambulatory of an internal specialist a number of patients suffering from angina pectoris or hypertonia together with arrhythmic troubles received an initial treatment with beta-blockers over a period of 21 days. In cases in which arrhythmia persisted after this initial period the treatment was continued for another 21 days with the addition of Depasan retard in function of a second medicament. This combined treatment in form of an open study was extended to a total number of 50 patients presenting ventricular extrasystolia in 45 cases and in 5 cases absolute arrhythmia in addition to the main disease. Treatment with Depasan retard showed good or satisfactory results in 39 out of 45 patients suffering from ventricular extrasystoles, whilst no effect could be obtained in the 5 cases with absolute arrhythmia. No signs of incompatibility or unwanted interactions were observed in the course of this open study. Based on these results it can be concluded that Depasan retard should be recommended in those cases where on account of persistent arrhythmical troubles and especially extrasystoles, during a treatment with beta-blockers in patients suffering from angina pectoris or hypertonia, and additional treatment with anti-arrhythmical medicaments appears to be indicated.

  3. Plant-wide integrated equipment monitoring and analysis system

    International Nuclear Information System (INIS)

    Morimoto, C.N.; Hunter, T.A.; Chiang, S.C.

    2004-01-01

    A nuclear power plant equipment monitoring system monitors plant equipment and reports deteriorating equipment conditions. The more advanced equipment monitoring systems can also provide information for understanding the symptoms and diagnosing the root cause of a problem. Maximizing the equipment availability and minimizing or eliminating consequential damages are the ultimate goals of equipment monitoring systems. GE Integrated Equipment Monitoring System (GEIEMS) is designed as an integrated intelligent monitoring and analysis system for plant-wide application for BWR plants. This approach reduces system maintenance efforts and equipment monitoring costs and provides information for integrated planning. This paper describes GEIEMS and how the current system is being upgraded to meet General Electric's vision for plant-wide decision support. (author)

  4. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  5. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  6. Risk of malignant arrhythmias in initially symptomatic patients with Wolff-Parkinson-White syndrome: results of a prospective long-term electrophysiological follow-up study.

    Science.gov (United States)

    Pappone, Carlo; Vicedomini, Gabriele; Manguso, Francesco; Baldi, Mario; Pappone, Alessia; Petretta, Andrea; Vitale, Raffaele; Saviano, Massimo; Ciaccio, Cristiano; Giannelli, Luigi; Calovic, Zarko; Tavazzi, Luigi; Santinelli, Vincenzo

    2012-02-07

    The available amount of detailed long-term data in patients with Wolff-Parkinson-White syndrome is limited, and no prospective electrophysiological studies looking at predictors of malignant arrhythmia are available. Among 8575 symptomatic Wolff-Parkinson-White patients with atrioventricular reentrant tachycardia referred for electrophysiological test, 369 (mean age, 23±12.5 years) declined catheter ablation and were followed up. The primary end point of the study was to evaluate over a 5-year follow-up the predictors and characteristics of patients who develop malignant arrhythmias. After a mean follow-up of 42.1±10 months, malignant arrhythmias developed in 29 patients (mean age, 13.9±5.6 years; 26 male), resulting in presyncope/syncope (25 patients), hemodynamic collapse (3 patients), or cardiac arrest caused by ventricular fibrillation (1 patient). Of the remaining 340 patients, 168 (mean age, 34.2±9.0 years) remained asymptomatic up to 5 years, and 172 (mean age, 13.6±5.1 years) had benign recurrence, including sustained atrioventricular reentrant tachycardia (132 patients) or atrial fibrillation (40 patients). Compared with the group with no malignant arrhythmias, the group with malignant arrhythmias showed shorter accessory-pathway effective refractory period (PWolff-Parkinson-White syndrome generally have a good outcome, and predictors of malignant arrhythmias are similar to those reported for asymptomatic patients with ventricular pre-excitation.

  7. Automatic detection of measurement points for non-contact vibrometer-based diagnosis of cardiac arrhythmias

    Science.gov (United States)

    Metzler, Jürgen; Kroschel, Kristian; Willersinn, Dieter

    2017-03-01

    Monitoring of the heart rhythm is the cornerstone of the diagnosis of cardiac arrhythmias. It is done by means of electrocardiography which relies on electrodes attached to the skin of the patient. We present a new system approach based on the so-called vibrocardiogram that allows an automatic non-contact registration of the heart rhythm. Because of the contactless principle, the technique offers potential application advantages in medical fields like emergency medicine (burn patient) or premature baby care where adhesive electrodes are not easily applicable. A laser-based, mobile, contactless vibrometer for on-site diagnostics that works with the principle of laser Doppler vibrometry allows the acquisition of vital functions in form of a vibrocardiogram. Preliminary clinical studies at the Klinikum Karlsruhe have shown that the region around the carotid artery and the chest region are appropriate therefore. However, the challenge is to find a suitable measurement point in these parts of the body that differs from person to person due to e. g. physiological properties of the skin. Therefore, we propose a new Microsoft Kinect-based approach. When a suitable measurement area on the appropriate parts of the body are detected by processing the Kinect data, the vibrometer is automatically aligned on an initial location within this area. Then, vibrocardiograms on different locations within this area are successively acquired until a sufficient measuring quality is achieved. This optimal location is found by exploiting the autocorrelation function.

  8. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  9. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA

    Directory of Open Access Journals (Sweden)

    Christie E Tung

    2015-01-01

    Full Text Available Background: It is important to evaluate patients with TIA or stroke for atrial fibrillation (AF because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch in patients with stroke or TIA.Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies. Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. Results: 1,171 monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0. The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%. AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 hours. The mean PAF burden was 12.7% of the total monitoring duration. Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 hours of monitoring suggest that the cardiac patch is superior to conventional 48-hour Holter monitors for AF detection in patients with stroke or TIA.

  10. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA.

    Science.gov (United States)

    Tung, Christie E; Su, Derek; Turakhia, Mintu P; Lansberg, Maarten G

    2014-01-01

    It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA. We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration. Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.

  11. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  12. Remote supervision of GIS monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pannunzio, J.; Juge, P.; Ficheux, A.; Rayon, J.L. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada)

    2007-07-01

    Operators of gas-insulated substations (GIS) are increasingly concerned with failure prevention, scheduled maintenance, personnel safety and shortage of maintenance crews. Until recently, the density levels of the insulating gas sulfur hexafluoride (SF6) was the only parameter controlled in gas-insulated substations. Modern digital type control and monitoring equipment have been widely used in the past decade. Remote indication of gas density and status of dynamic components was made possible and shown on local control panels. Modern GIS monitoring systems offer features such as SF6 monitoring, SF6 leakage trends, internal arc localization and detection. The required information is recorded in a local computer and displaced onto a local human machine interface (HMI) or a local industrial PC mounted next to the GIS. These monitoring systems are used as decision making tools to facilitate maintenance activities and optimize the management of assets. This paper presented the latest developments in digital monitoring systems in terms of modern digital architecture; management of information flows between monitoring systems and control systems; operation of remote supervision; configuration of high voltage substations and information sharing; and, types of links between GIS room and remote supervision. This paper also demonstrated what can be achieved by moving the central HMI of a GIS monitoring system to the decision-making centres. It was shown that integrated features that allow remote on-line or automated management have reached an acceptable level of reliability and comfort for operators. 5 figs.

  13. System of message for gamma-radiation monitor

    International Nuclear Information System (INIS)

    Bolic, M.D.; Koturovic, A.M.

    2001-01-01

    Paper describes a system of voice messages for gamma-radiation monitor based on PC. The systems reproduces recorded messages that is simpler than the process of their synthesis. Message choice is based on combination of recorded digital results and/or received reference messages or warnings. The system of generation of voice messages applies the Windows based software. The total memory array required to create independent voice system is maximum 1.7 mbyte. The monitor may be used for continuous monitoring of radioactivity level with 5-8 s period of message repetition. Another option of the system operation is based on monitor application for the environment monitoring. Period of messages in this case is equal to 5-30 min [ru

  14. Stack Monitoring System At PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin

    2014-01-01

    This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)

  15. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  16. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    Science.gov (United States)

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  17. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  18. Enhanced 911/global position system wizard: a telemedicine application for the prevention of severe hypoglycemia--monitor, alert, and locate.

    Science.gov (United States)

    Dassau, Eyal; Jovanovic, Lois; Doyle, Francis J; Zisser, Howard C

    2009-11-01

    Intensive insulin therapy has an inherent risk of hypoglycemia that can lead to loss of consciousness, cardiac arrhythmia, seizure, and death ("dead-in-bed syndrome"). This risk of hypoglycemia is a major concern for patients, families, and physicians. The need for an automated system that can alert in the event of severe hypoglycemia is evident. In engineering systems, where there is a risk of malfunction of the primary control system, alert and safety mechanisms are implemented in layers of protection. This concept has been adopted in the proposed system that integrates a hypoglycemia prediction algorithm with a global position system (GPS) locator and short message service such that the current glucose value with the rate of change (ROC) and the location of the subject can be communicated to a predefined list. Furthermore, if the system is linked to the insulin pump, it can suspend the pump or decrease the basal insulin infusion rate to prevent the pending event. The system was evaluated on clinical datasets of glucose tracings from the DexCom Seven system. Glucose tracings were analyzed for hypoglycemia events and then a text message was broadcast to a predefined list of people who were notified with the glucose value, ROC, GPS coordinates, and a Google map of the location. In addition to providing a safety layer to a future artificial pancreas, this system also can be easily implemented in current continuous glucose monitors to help provide information and alerts to people with diabetes.

  19. Anti-HERG activity and the risk of drug-induced arrhythmias and sudden death

    DEFF Research Database (Denmark)

    De Bruin, M L; Pettersson, M; Meyboom, R H B

    2005-01-01

    AIMS: Drug-induced QTc-prolongation, resulting from inhibition of HERG potassium channels may lead to serious ventricular arrhythmias and sudden death. We studied the quantitative anti-HERG activity of pro-arrhythmic drugs as a risk factor for this outcome in day-to-day practice. METHODS...... defined as reports of cardiac arrest, sudden death, torsade de pointes, ventricular fibrillation, and ventricular tachycardia (n = 5591), and compared with non-cases regarding the anti-HERG activity, defined as the effective therapeutic plasma concentration (ETCPunbound) divided by the HERG IC50 value......, of suspected drugs. We identified a significant association of 1.93 (95% CI: 1.89-1.98) between the anti-HERG activity of drugs, measured as log10 (ETCPunbound/IC50), and reporting of serious ventricular arrhythmias and sudden death to the WHO-UMC database. CONCLUSION: Anti-HERG activity is associated...

  20. AANA Journal Course: update for nurse anesthetists. Arrhythmia management devices and electromagnetic interference.

    Science.gov (United States)

    Mattingly, Emily

    2005-04-01

    The technological complexity of implantable arrhythmia management devices, specifically pacemakers and defibrillators, has increased dramatically since their introduction only a few decades ago. Patients with such devices are encountered much more frequently in hospitals and surgery centers, yet anesthesia provider knowledge of safe and proper management is often incomplete. Anesthesia textbooks and references may provide only short paragraphs on arrhythmia management devices that do not address important perioperative management strategies for this ever-growing patient population. It is no longer satisfactory to simply place a magnet over an implanted device during surgery and assume that this action protects the patient from harm due to electromagnetic interference from inappropriate device function. This AANA Journal course serves as a concise review of basic device function, the sources and effects of electromagnetic interference in the operative setting, and patient management recommendations from current literature.

  1. A unique radiation area monitoring system

    International Nuclear Information System (INIS)

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  2. Communicating with Professionals

    Medline Plus

    Full Text Available ... Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & Treatment of Arrhythmia Arrhythmia Tools & Resources Cholesterol About ...

  3. Coping with Feelings

    Medline Plus

    Full Text Available ... Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & Treatment of Arrhythmia Arrhythmia Tools & Resources Cholesterol About ...

  4. Drinking-water monitoring systems

    International Nuclear Information System (INIS)

    1994-01-01

    A new measuring system was developed by the Austrian Research Centre Seibersdorf for monitoring the quality of drinking-water. It is based on the experience made with the installation of UWEDAT (registered trademark) environmental monitoring networks in several Austrian provinces and regions. The standard version of the drinking-water monitoring system comprises sensors for measuring chemical parameters in water, radioactivity in water and air, and meteorological values of the environment. Further measuring gauges, e.g. for air pollutants, can be connected at any time, according to customers' requirements. For integration into regional and supraregional networks, station computers take over the following tasks: Collection of data and status signals transmitted by the subsystem, object protection, intermediate storage and communication of data to the host or several subcentres via Datex-P postal service, permanent lines or radiotransmission

  5. Scintigraphic assessment of cardiac sympathetic innervation with I-123-metaiodobenzylguanidine in cardiomyopathy. Special reference to cardiac arrhythmia

    Energy Technology Data Exchange (ETDEWEB)

    Asano, Takahisa; Otsuka, Nobuaki; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Tomomitsu, Tatsushi; Fukunaga, Masao [Kawasaki Medical School, Kurashiki, Okayama (Japan); Morita, Koichi

    1999-07-01

    Cardiac sympathetic imagings with I-123-metaiodobenzylguanidine (MIBG) were carried out in 5 cases with dilated cardiomyopathy (DCM), 26 cases with hypertrophic cardiomyopathy (HCM), and 4 cases without cardiac disease as a control to assess cardiac sympathetic innervation qualitatively and quantitatively, and to clarify the relation of MIBG accumulation to arrhythmia. MIBG scintigraphy was performed at 15 min. (early image) and 4 hr. (delayed image) after intravenous injection of MIBG 111 MBq. The MIBG uptake ratio of mediastinum (H/M) and the cardiac washout rate (WR) from early to delayed images were calculated. On both early and delayed SPECTs, MIBG uptake was assessed by defect scores (DSs). Regarding the cases with HCM, the MIBG uptake ratio, WR, and DS were also compared in cases with and without arrhythmia. In DCM, the MIBG uptake on delayed SPECT was markedly low, the H/M ratio was significantly lower, and the DS was significantly higher than in the control (all p<0.05). As for the WR, there was no significant difference between HCM, DCM and the control. In HCM, significantly reduced MIBG uptake was observed in cases with ventricular techycardia (VT) and in cases with atrial fibrillation (Af), as compared with cases without arrhythmia (all p<0.05). There results suggest that MIBG scintigraphy might be a useful tool in the assessment of cardiac sympathetic abnormalities in cardiomyopathy, especially in cases with arrhythmia. (author)

  6. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  7. Late gadolinium enhancement by magnetic resonance explains adverse cardiac events in individuals with ventricular arrhythmia

    International Nuclear Information System (INIS)

    Courtis, J.; Vasallo, J.; Arabia, L.; Dimitroff, M.; Gonzalez, A.; Tibaldi, M.

    2012-01-01

    Objective: To determine whether the presence of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) predict adverse cardiac events in patients with ventricular arrhythmia. Methods: We selected 74 consecutive patients with symptomatic ventricular arrhythmia (premature ventricular contractions and ventricular tachycardia) and left ventricular ejection fraction (LVEF) >55% sent to CMR for evaluation of structural heart disease previously undetected by other complementary methods. LGE, systolic function and volumes of both ventricles were analyzed. At follow-up was assessed a combined end point: hospitalization for ventricular arrhythmia, appropriate implantable cardioverter-defibrillator therapy and cardiac death. Results: During a median follow up of 575 days (interquartile range 24-1120 days) and by analyzing the population according to the presence (n=9, 12%) or not (n=65, 88%) LGE was observed that the group with positive Gd had lower LVEF (58% vs. 66% respectively, p=0.01) and larger volumes (EDV: 185 ml vs. 123 ml respectively, p=0.01 and ESV: 81 ml vs. 42 ml respectively, p=0.01) than the other group. Two (22%) patients in the LGE + group vs. one (4%) of those without LGE showed the combined endpoint (p=0.01) and when performing a logistic regression analysis it was found that the LGE is a predictor of adverse cardiac events analyzed (p=0.029). Conclusions: In this consecutive series of patients with ventricular arrhythmia we demonstrate a strong association between myocardial LGE and adverse cardiac events; this supports the hypothesis that myocardial fibrosis is an important arrhythmogenic substrate. In addition, almost all individuals without LGE were free of events during follow-up suggesting that it is possible to identify through the CMR low-risk individuals who can be treated conservatively. (authors) [es

  8. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  9. Dental caries, periodontal disease, and cardiac arrhythmias in community-dwelling older persons aged 80 and older: is there a link?

    DEFF Research Database (Denmark)

    Holm-Pedersen, Poul; Avlund, Kirsten; Morse, Douglas E

    2005-01-01

    lesions had 2.8 times higher odds (95% confidence interval=1.1-7.0) of arrhythmia than persons without active coronal caries, but there was no greater risk for persons with three or more coronal caries lesions. There was no association between periodontal disease and arrhythmia. CONCLUSION: The findings......OBJECTIVES: To examine whether caries or periodontitis is associated with cardiac arrhythmias in community-dwelling people aged 80 and older. SETTING: Urban, community-based population in Stockholm, Sweden. DESIGN: Cross-sectional. PARTICIPANTS: Eligible persons were identified through...... by a physician or the Stockholm Inpatient Register. Active root caries, active coronal caries, and periodontitis were assessed using previously defined National Institute of Dental and Craniofacial Research diagnostic criteria. RESULTS: The primary finding of the multivariate logistic regression analysis...

  10. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  11. Critical function monitoring system algorithm development

    International Nuclear Information System (INIS)

    Harmon, D.L.

    1984-01-01

    Accurate critical function status information is a key to operator decision-making during events threatening nuclear power plant safety. The Critical Function Monitoring System provides continuous critical function status monitoring by use of algorithms which mathematically represent the processes by which an operating staff would determine critical function status. This paper discusses in detail the systematic design methodology employed to develop adequate Critical Function Monitoring System algorithms

  12. hERG trafficking inhibition in drug-induced lethal cardiac arrhythmia.

    Science.gov (United States)

    Nogawa, Hisashi; Kawai, Tomoyuki

    2014-10-15

    Acquired long QT syndrome induced by non-cardiovascular drugs can cause lethal cardiac arrhythmia called torsades de points and is a significant problem in drug development. The prolongation of QT interval and cardiac action potential duration are mainly due to reduced physiological function of the rapidly activating voltage-dependent potassium channels encoded by human ether-a-go-go-related gene (hERG). Structurally diverse groups of drugs are known to directly inhibit hERG channel conductance. Therefore, the ability of acute hERG inhibition is routinely assessed at the preclinical stages in pharmaceutical testing. Recent findings indicated that chronic treatment with various drugs not only inhibits hERG channels but also decreases hERG channel expression in the plasma membrane of cardiomyocytes, which has become another concern in safety pharmacology. The mechanisms involve the disruption of hERG trafficking to the surface membrane or the acceleration of hERG protein degradation. From this perspective, we present a brief overview of mechanisms of drug-induced trafficking inhibition and pathological regulation. Understanding of drug-induced hERG trafficking inhibition may provide new strategies for predicting drug-induced QT prolongation and lethal cardiac arrhythmia in pharmaceutical drug development. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo

    1993-03-01

    Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)

  14. The efficacy of radiofrequency ablation in the treatment of pediatric arrhythmia and its effects on serum IL-6 and hs-CRP.

    Science.gov (United States)

    Li, Chunli; Jia, Libo; Wang, Zhenzhou; Niu, Ling; An, Xinjiang

    2017-10-01

    The aim of this study was to investigate the efficacy of radiofrequency ablation in the treatment of pediatric arrhythmia and to assess the changes in serum interleukin-6 (IL-6) and hs-CRP levels after treatment. Hundred and six children with tachyarrhythmia who were admitted to Xuzhou Children's Hospital from November, 2014 to December, 2015 were recruited for study. The efficacies of radiofrequency in the treatment of different types of arrhythmia were analyzed. Successful ablation was found in 104 cases (98.11%) and recurrence was found in 7 cases (6.73%). Among 62 cases of atrioventricular reentrant tachycardia (AVRT), successful ablation was found in 60 cases (96.77%) and recurrence was found in 3 cases (4.84%). Among 33 cases of atrioventricular nodal reentrant tachycardia (AVNRT), successful ablation was found in 33 cases (100%) and recurrence was found in 2 cases (6.06%). Among 5 cases of ventricular tachycardia (VT), successful ablation was found in 5 cases (100%) and no recurrence was found. Among 4 cases of atrial tachycardia (AT), successful ablation was found in 4 cases (100%) and recurrence was found in 1 case (25%). Among 2 cases of atrial flutter (AFL), successful ablation was found in both (100%) and recurrence was found in 1 case (50%). After operation, the levels of IL-6 and hs-CRP were increased and were continually increased within 6 h after operation. The levels of IL-6 and hs-CRP at 24 h after operation were reduced but still higher than preoperative levels. The duration of radiofrequency and ablation energy were positively correlated with the levels of IL-6 and hs-CRP, while the number of discharges was not significantly correlated with either. In conclusion, radiofrequency ablation is a safe and effective treatment for pediatric arrhythmia. Postoperative monitoring of IL-6 and hs-CRP levels is conducive to understanding postoperative myocardial injury and inflammatory response.

  15. Distributed intelligent urban environment monitoring system

    Science.gov (United States)

    Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang

    2018-02-01

    The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion

  16. Exercise-induced ventricular arrhythmias and vagal dysfunction in Chagas disease patients with no apparent cardiac involvement

    Directory of Open Access Journals (Sweden)

    Henrique Silveira Costa

    2015-04-01

    Full Text Available INTRODUCTION : Exercise-induced ventricular arrhythmia (EIVA and autonomic imbalance are considered as early markers of heart disease in Chagas disease (ChD patients. The objective of the present study was to verify the differences in the occurrence of EIVA and autonomic maneuver indexes between healthy individuals and ChD patients with no apparent cardiac involvement. METHODS : A total of 75 ChD patients with no apparent cardiac involvement, aged 44.7 (8.5 years, and 38 healthy individuals, aged 44.0 (9.2 years, were evaluated using echocardiography, symptom-limited treadmill exercise testing and autonomic function tests. RESULTS : The occurrence of EIVA was higher in the chagasic group (48% than in the control group (23.7% during both the effort and the recovery phases. Frequent ventricular contractions occurred only in the patient group. Additionally, the respiratory sinus arrhythmia index was significantly lower in the chagasic individuals compared with the control group. CONCLUSIONS : ChD patients with no apparent cardiac involvement had a higher frequency of EIVA as well as more vagal dysfunction by respiratory sinus arrhythmia. These results suggest that even when asymptomatic, ChD patients possess important arrhythmogenic substrates and subclinical disease.

  17. Noninvasive predictors of perioperative atrial arrhythmias in patients with tetralogy of Fallot undergoing pulmonary valve replacement.

    Science.gov (United States)

    Cortez, Daniel; Barham, Waseem; Ruckdeschel, Emily; Sharma, Nandita; McCanta, Anthony C; von Alvensleben, Johannes; Sauer, William H; Collins, Kathryn K; Kay, Joseph; Patel, Sonali; Nguyen, Duy T

    2017-08-01

    Patients with tetralogy of Fallot (TOF) have increased risk of atrial arrhythmias. A measure of atrial dispersion, the P-wave vector magnitude (Pvm), can identify patients at risk for perioperative atrial flutter (AFL) or intra-atrial re-entrant tachycardia (IART) in a large TOF cohort. We performed a blinded, retrospective analysis of 158 TOF patients undergoing pulmonary valve replacement between 1997 and 2015. History of AFL/IART was documented using electrocardiogram, Holter monitor, exercise stress test, implanted cardiac device, and electrophysiology study. P-R intervals, Pvm, QRS duration, and QRS vector magnitude were assessed from resting sinus-rhythm 12-lead electrocardiograms and identification of those with AFL/IART was determined. Fourteen patients (8.9%) were found to have AFL/IART. Pvm, QRS duration, and QRS vector magnitude significantly differentiated those with AFL/IART from those without on univariate analysis: 0.09 ± 0.04 vs 0.18 ± 0.07 mV, 161.3 ± 21.9 vs 137.7 ± 31.4 ms, and 1.2 (interquartile range, 1.0-1.2) vs 1.6 mV (1.0-2.3), respectively (P < 0.05 for each). The Pvm had the highest area under the ROC curve (0.88) and was the only significant predictor on multivariate analysis, with odds ratio of 0.02 (95% confidence interval: 0.01-0.53). P-R duration, MRI volumes, and right-heart hemodynamics did not significantly differentiate those with vs those without AFL/IART. In TOF patients undergoing pulmonary valve replacement, Pvm has significant value in predicting those with perioperative AFL/IART. These clinical features may help further evaluate TOF patients at risk for perioperative atrial arrhythmias. Prospective studies are warranted. © 2017 Wiley Periodicals, Inc.

  18. The influence of type 2 diabetes mellitus on the frequency and complexity of ventricular arrhythmias and heart rate variability in patients after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Stoičkov Viktor

    2016-01-01

    Full Text Available Background/Aim. After myocardial infarction arrhythmic cardiac deaths are significantly more frequent compared to non-arrhythmic ones. The aim of the study was to investigate the influence of type 2 diabetes mellitus (T2DM on the frequency and complexity of ventricular arrhythmias after myocardial infarction. Methods. The study included 293 patients, mean age 59.5 ± 9.21 years, who were at least six months after acute myocardial infarction with the sinus rhythm, without atrioventricular blocks and branch blocks. In the clinical group 95 (32.42% patients were with T2DM, while 198 (67.57% patients were without diabetes. All of the patients were subjected to the following procedures: standard ECG according to which the corrected QT dispersion (QTdc was calculated, exercise stress test, and 24-hour holter monitoring according to which, the four parameters of time domain of heart rate variability (HRV were analyzed: standard deviation of all normal RR intervals during 24 hours (SDNN, standard deviation of the averages of normal RR intervals in all five-minute segments during 24 hours (SDANN, the square root of the mean of the sum of the squares of differences between adjacent normal (RMS-SD, and percentage of consequtive RR intervals which differed for more than 50 ms during 24 hours (NN > 50 ms. Results. In patients after myocardial infarction, patients with T2DM had significantly higher percentage of frequent and complex ventricular arrhythmias compared to the patients without diabetes (p 50 ms (p < 0.001, and significantly higher values of QTdc (p < 0.001 compared to the patients without diabetes. Conclusion. The study showed that type 2 diabetes mellitus has significant influence on ventricular arrhythmias, HRV parameters and QT dispersion in patients after myocardial infarction.

  19. Visualization System for Monitoring Data Management Systems

    Directory of Open Access Journals (Sweden)

    Emanuel Pinho

    2016-11-01

    Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.

  20. Online NPP monitoring with neuro-expert system

    International Nuclear Information System (INIS)

    Nabeshima, K.

    2002-01-01

    This study present a hybrid monitoring system for nuclear power plant utilizing neural networks and a rule-based expert system. The whole monitoring system including a data acquisition system and the advisory displays has been tested by an on-line simulator of pressurized water reactor. From the testing results, it was shown that the neural network in the monitoring system successfully modeled the plant dynamics and detected the symptoms of anomalies earlier than the conventional alarm system. The expert system also worked satisfactorily in diagnosing and displaying the system status by using the outputs of neural networks and a priori knowledge base

  1. Remote Monitoring of Cardiac Implantable Electronic Devices.

    Science.gov (United States)

    Cheung, Christopher C; Deyell, Marc W

    2018-01-08

    Over the past decade, technological advancements have transformed the delivery of care for arrhythmia patients. From early transtelephonic monitoring to new devices capable of wireless and cellular transmission, remote monitoring has revolutionized device care. In this article, we review the current evolution and evidence for remote monitoring in patients with cardiac implantable electronic devices. From passive transmission of device diagnostics, to active transmission of patient- and device-triggered alerts, remote monitoring can shorten the time to diagnosis and treatment. Studies have shown that remote monitoring can reduce hospitalization and emergency room visits, and improve survival. Remote monitoring can also reduce the health care costs, while providing increased access to patients living in rural or marginalized communities. Unfortunately, as many as two-thirds of patients with remote monitoring-capable devices do not use, or are not offered, this feature. Current guidelines recommend remote monitoring and interrogation, combined with annual in-person evaluation in all cardiac device patients. Remote monitoring should be considered in all eligible device patients and should be considered standard of care. Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  3. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  4. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  5. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, H.; Kobalyashi, H.

    1993-01-01

    JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles

  6. Life Support Systems: Environmental Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems (AES) Life Support Systems project Environmental Monitoring (EM) systems task objectives are to develop and demonstrate onboard...

  7. Acoustic emission leak monitoring system LMS-96

    International Nuclear Information System (INIS)

    Liska, J.; Cvrcek, M.; Mueller, L.

    1997-01-01

    On-line acoustic emission leak monitoring under industrial conditions of nuclear power plants is a problem with specific features setting specific demands on the leak monitoring system. The paper briefly reviews those problems (attenuation pattern of a real structure, acoustic background, alarm system, etc.) and the solution of some of them is discussed. Information is presented on the Acoustic Emission Leak Monitoring System LMS-96 by SKODA NUCLEAR MACHINERY and the system's function is briefly described. (author)

  8. Arrhythmia-provoking factors and symptoms at the onset of paroxysmal atrial fibrillation: A study based on interviews with 100 patients seeking hospital assistance

    Directory of Open Access Journals (Sweden)

    Madsen-Härdig Bjarne

    2004-08-01

    Full Text Available Abstract Background Surprisingly little information on symptoms of paroxysmal atrial fibrillation is available in scientific literature. Using questionnaires, we have analyzed the symptoms associated with arrhythmia attacks. Methods One hundred randomly-selected patients with idiopathic paroxysmal atrial fibrillation filled in a structured questionnaire. Results Psychic stress was the most common factor triggering arrhythmia (54%, followed by physical exertion (42%, tiredness (41% coffee (25% and infections (22%. Thirty-four patients cited alcohol, 26 in the form of red wine, 16 as white wine and 26 as spirits. Among these 34, red wine and spirits produced significantly more episodes of arrhythmia than white wine (p = 0.01 and 0.005 respectively. Symptoms during arrhythmia were palpitations while exerting (88%, reduced physical ability (87%, palpitations at rest (86%, shortage of breath during exertion (70% and anxiety (59%. Significant differences between sexes were noted regarding swollen legs (women 21%, men 6%, p = 0.027, nausea (women 36%, men 13%, p = 0.012 and anxiety (females 79%, males 51%, p = 0.014. Conclusion Psychic stress was the commonest triggering factor in hospitalized patients with paroxysmal atrial fibrillation. Red wine and spirits were more proarrhythmic than white wine. Symptoms in women in connection with attacks of arrhythmia vary somewhat from those in men.

  9. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  10. Nonischemic Left Ventricular Scar as a Substrate of Life-Threatening Ventricular Arrhythmias and Sudden Cardiac Death in Competitive Athletes.

    Science.gov (United States)

    Zorzi, Alessandro; Perazzolo Marra, Martina; Rigato, Ilaria; De Lazzari, Manuel; Susana, Angela; Niero, Alice; Pilichou, Kalliopi; Migliore, Federico; Rizzo, Stefania; Giorgi, Benedetta; De Conti, Giorgio; Sarto, Patrizio; Serratosa, Luis; Patrizi, Giampiero; De Maria, Elia; Pelliccia, Antonio; Basso, Cristina; Schiavon, Maurizio; Bauce, Barbara; Iliceto, Sabino; Thiene, Gaetano; Corrado, Domenico

    2016-07-01

    The clinical profile and arrhythmic outcome of competitive athletes with isolated nonischemic left ventricular (LV) scar as evidenced by contrast-enhanced cardiac magnetic resonance remain to be elucidated. We compared 35 athletes (80% men, age: 14-48 years) with ventricular arrhythmias and isolated LV subepicardial/midmyocardial late gadolinium enhancement (LGE) on contrast-enhanced cardiac magnetic resonance (group A) with 38 athletes with ventricular arrhythmias and no LGE (group B) and 40 healthy control athletes (group C). A stria LGE pattern with subepicardial/midmyocardial distribution, mostly involving the lateral LV wall, was found in 27 (77%) of group A versus 0 controls (group C; P<0.001), whereas a spotty pattern of LGE localized at the junction of the right ventricle to the septum was respectively observed in 11 (31%) versus 10 (25%; P=0.52). All athletes with stria pattern showed ventricular arrhythmias with a predominant right bundle branch block morphology, 13 of 27 (48%) showed ECG repolarization abnormalities, and 5 of 27 (19%) showed echocardiographic hypokinesis of the lateral LV wall. The majority of athletes with no or spotty LGE pattern had ventricular arrhythmias with a predominant left bundle branch block morphology and no ECG or echocardiographic abnormalities. During a follow-up of 38±25 months, 6 of 27 (22%) athletes with stria pattern experienced malignant arrhythmic events such as appropriate implantable cardiac defibrillator shock (n=4), sustained ventricular tachycardia (n=1), or sudden death (n=1), compared with none of athletes with no or LGE spotty pattern and controls. Isolated nonischemic LV LGE with a stria pattern may be associated with life-threatening arrhythmias and sudden death in the athlete. Because of its subepicardial/midmyocardial location, LV scar is often not detected by echocardiography. © 2016 The Authors.

  11. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  12. Arrhythmia causes lipid accumulation and reduced glucose uptake.

    Science.gov (United States)

    Lenski, Matthias; Schleider, Gregor; Kohlhaas, Michael; Adrian, Lucas; Adam, Oliver; Tian, Qinghai; Kaestner, Lars; Lipp, Peter; Lehrke, Michael; Maack, Christoph; Böhm, Michael; Laufs, Ulrich

    2015-01-01

    Atrial fibrillation (AF) is characterized by irregular contractions of atrial cardiomyocytes and increased energy demand. The aim of this study was to characterize the influence of arrhythmia on glucose and fatty acid (FA) metabolism in cardiomyocytes, mice and human left atrial myocardium. Compared to regular pacing, irregular (pseudo-random variation at the same number of contractions/min) pacing of neonatal rat cardiomyocytes induced shorter action potential durations and effective refractory periods and increased diastolic [Ca(2+)]c. This was associated with the activation of Ca(2+)/calmodulin-dependent protein kinase II (CaMKII) and AMP-activated protein kinase (AMPK). Membrane expression of fatty acid translocase (FAT/CD36) and (14)C-palmitic acid uptake were augmented while membrane expression of glucose transporter subtype 4 (GLUT-4) as well as (3)H-glucose uptake were reduced. Inhibition of AMPK and CaMKII prevented these arrhythmia-induced metabolic changes. Similar alterations of FA metabolism were observed in a transgenic mouse model (RacET) for spontaneous AF. Consistent with these findings samples of left atrial myocardium of patients with AF compared to matched samples of patients with sinus rhythm showed up-regulation of CaMKII and AMPK and increased membrane expression of FAT/CD36, resulting in lipid accumulation. These changes of FA metabolism were accompanied by decreased membrane expression of GLUT-4, increased glycogen content and increased expression of the pro-apoptotic protein bax. Irregular pacing of cardiomyocytes increases diastolic [Ca(2+)]c and activation of CaMKII and AMPK resulting in lipid accumulation, reduced glucose uptake and increased glycogen synthesis. These metabolic changes are accompanied by an activation of pro-apoptotic signalling pathways.

  13. Taming of the monitors: reducing false alarms in intensive care units

    Czech Academy of Sciences Publication Activity Database

    Plešinger, Filip; Klimeš, Petr; Halámek, Josef; Jurák, Pavel

    2016-01-01

    Roč. 37, č. 8 (2016), s. 1313-1325 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2034; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : ECG * critical care * arrhythmia * intensive care unit * ICU monitor * false alarm * beat detection Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 2.058, year: 2016

  14. Flecainide Therapy Reduces Exercise-Induced Ventricular Arrhythmias in Patients With Catecholaminergic Polymorphic Ventricular Tachycardia

    NARCIS (Netherlands)

    van der Werf, Christian; Kannankeril, Prince J.; Sacher, Frederic; Krahn, Andrew D.; Viskin, Sami; Leenhardt, Antoine; Shimizu, Wataru; Sumitomo, Naokata; Fish, Frank A.; Bhuiyan, Zahurul A.; Willems, Albert R.; van der Veen, Maurits J.; Watanabe, Hiroshi; Laborderie, Julien; Haïssaguerre, Michel; Knollmann, Björn C.; Wilde, Arthur A. M.

    2011-01-01

    Objectives This study evaluated the efficacy and safety of flecainide in addition to conventional drug therapy in patients with catecholaminergic polymorphic ventricular tachycardia (CPVT). Background CPVT is an inherited arrhythmia syndrome caused by gene mutations that destabilize cardiac

  15. Uranium concentration monitor manual: 2300 system

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.

    1985-04-01

    This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs

  16. Standard-D hydrogen monitoring system, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1996-01-01

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS

  17. Radiation monitoring system based on EPICS

    International Nuclear Information System (INIS)

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)

  18. FFTF fission gas monitor computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be controlled by the computer, allowing the system to provide rapid system self tests and operational performance reports

  19. A real time ECG signal processing application for arrhythmia detection on portable devices

    Science.gov (United States)

    Georganis, A.; Doulgeraki, N.; Asvestas, P.

    2017-11-01

    Arrhythmia describes the disorders of normal heart rate, which, depending on the case, can even be fatal for a patient with severe history of heart disease. The purpose of this work is to develop an application for heart signal visualization, processing and analysis in Android portable devices e.g. Mobile phones, tablets, etc. The application is able to retrieve the signal initially from a file and at a later stage this signal is processed and analysed within the device so that it can be classified according to the features of the arrhythmia. In the processing and analysing stage, different algorithms are included among them the Moving Average and Pan Tompkins algorithm as well as the use of wavelets, in order to extract features and characteristics. At the final stage, testing is performed by simulating our application in real-time records, using the TCP network protocol for communicating the mobile with a simulated signal source. The classification of ECG beat to be processed is performed by neural networks.

  20. Ambulatory cardiac arrhythmias in relation to mild hypokalaemia and prognosis in community dwelling middle-aged and elderly subjects

    DEFF Research Database (Denmark)

    Mattsson, Nick; Sadjadieh, Golnaz; Kumarathurai, Preman

    2016-01-01

    with frequency of premature ventricular complexes (PVCs) especially in combination with diuretic treatment (r = -0.22, P = 0.015). Hypokalaemia was not associated with supraventricular arrhythmias. Subjects at lowest quintile of p-potassium (mean 3.42, range 2.7-3.6 mmol/L) were defined as hypokalaemic......, 10 and 15 per 1000 patient-year in those with one abnormality, and 3 per 1000 patient-year in subjects with no abnormality. One variable combining hypokalaemia with excessive supraventricular arrhythmias gave similar results in univariate analysis, but not after multivariate adjustments. CONCLUSION...

  1. Prevention of fatal arrhythmias in high-risk subjects by fish oil n-3 fatty acid intake.

    Science.gov (United States)

    Leaf, Alexander; Albert, Christine M; Josephson, Mark; Steinhaus, David; Kluger, Jeffrey; Kang, Jing X; Cox, Benjamin; Zhang, Hui; Schoenfeld, David

    2005-11-01

    The long-chain n-3 fatty acids in fish have been demonstrated to have antiarrhythmic properties in experimental models and to prevent sudden cardiac death in a randomized trial of post-myocardial infarction patients. Therefore, we hypothesized that these n-3 fatty acids might prevent potentially fatal ventricular arrhythmias in high-risk patients. Four hundred two patients with implanted cardioverter/defibrillators (ICDs) were randomly assigned to double-blind treatment with either a fish oil or an olive oil daily supplement for 12 months. The primary end point, time to first ICD event for ventricular tachycardia or fibrillation (VT or VF) confirmed by stored electrograms or death from any cause, was analyzed by intention to treat. Secondary analyses were performed for "probable" ventricular arrhythmias, "on-treatment" analyses for all subjects who had taken any of their oil supplements, and "on-treatment" analyses only of those subjects who were on treatment for at least 11 months. Compliance with double-blind treatment was similar in the 2 groups; however, the noncompliance rate was high (35% of all enrollees). In the primary analysis, assignment to treatment with the fish oil supplement showed a trend toward a prolonged time to the first ICD event (VT or VF) or of death from any cause (risk reduction of 28%; P=0.057). When therapies for probable episodes of VT or VF were included, the risk reduction became significant at 31%; P=0.033. For those who stayed on protocol for at least 11 months, the antiarrhythmic benefit of fish oil was improved for those with confirmed events (risk reduction of 38%; P=0.034). Although significance was not achieved for the primary end point, this study provides evidence that for individuals at high risk of fatal ventricular arrhythmias, regular daily ingestion of fish oil fatty acids may significantly reduce potentially fatal ventricular arrhythmias.

  2. Moisture monitoring and control system engineering study

    International Nuclear Information System (INIS)

    Carpenter, K.E.; Fadeff, J.G.

    1995-01-01

    During the past 50 years, a wide variety of chemical compounds have been placed in the 149 single-shell tanks (SSTS) on the Hanford Site. A concern relating to chemical stability, chemical control, and safe storage of the waste is the potential for propagating reactions as a result of ferrocyanide-oxidizer and organic-oxidizer concentrations in the SSTS. Propagating reactions in fuel-nitrate mixtures are precluded if the amounts of fuel and moisture present in the waste are within specified limits. Because most credible ignition sources occur near the waste surface, the main emphasis of this study is toward monitoring and controlling moisture in the top 14 cm (5.5 in.) of waste. The purpose of this engineering study is to recommend a moisture monitoring and control system for use in SSTs containing sludge and saltcake. This study includes recommendations for: (1) monitoring and controlling moisture in SSTs; (2) the fundamental design criteria for a moisture monitoring and control system; and (3) criteria for the deployment of a moisture monitoring and control system in hanford Site SSTs. To support system recommendations, technical bases for selecting and using a moisture monitoring and control system are presented. Key functional requirements and a conceptual design are included to enhance system development and establish design criteria

  3. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  4. Risk Prediction of One-Year Mortality in Patients with Cardiac Arrhythmias Using Random Survival Forest

    Directory of Open Access Journals (Sweden)

    Fen Miao

    2015-01-01

    Full Text Available Existing models for predicting mortality based on traditional Cox proportional hazard approach (CPH often have low prediction accuracy. This paper aims to develop a clinical risk model with good accuracy for predicting 1-year mortality in cardiac arrhythmias patients using random survival forest (RSF, a robust approach for survival analysis. 10,488 cardiac arrhythmias patients available in the public MIMIC II clinical database were investigated, with 3,452 deaths occurring within 1-year followups. Forty risk factors including demographics and clinical and laboratory information and antiarrhythmic agents were analyzed as potential predictors of all-cause mortality. RSF was adopted to build a comprehensive survival model and a simplified risk model composed of 14 top risk factors. The built comprehensive model achieved a prediction accuracy of 0.81 measured by c-statistic with 10-fold cross validation. The simplified risk model also achieved a good accuracy of 0.799. Both results outperformed traditional CPH (which achieved a c-statistic of 0.733 for the comprehensive model and 0.718 for the simplified model. Moreover, various factors are observed to have nonlinear impact on cardiac arrhythmias prognosis. As a result, RSF based model which took nonlinearity into account significantly outperformed traditional Cox proportional hazard model and has great potential to be a more effective approach for survival analysis.

  5. Ulysses spacecraft control and monitoring system

    Science.gov (United States)

    Hamer, P. A.; Snowden, P. J.

    1991-01-01

    The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.

  6. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  7. Heart rate turbulence and variability in patients with ventricular arrhythmias

    Directory of Open Access Journals (Sweden)

    Diego Tarricone

    2009-08-01

    Full Text Available Background: To evaluate the changes in autonomic neural control mechanisms before malignant ventricular arrhythmias, we measured heart rate variability (HRV and heart rate turbulence (HRT in patients with ventricular tachycardia or fibrillation (Group I; n=6, non sustained ventricular tachycardia (Group II; n=32, frequent premature ventricular beats (Group III; n=26 and with ICD implantation (Group IV; n=11. Methods: Time domain parameters of HRV and turbulence onset (TO and slope (TS were calculated on 24 hour Holter recordings. Normal values were: SDNN > 70 msec for HRV, TO <0% and TS >2.5 msec/RR-I for HRT. Results: Whereas SDNN was within normal range and similar in all study groups, HRT parameters were significantly different in patients who experienced VT/VF during Holter recording. Abnormal TO and/or TS were present in 100% of Group I patients and only in about 50% of Group II and IV. On the contrary, normal HRT parameters were present in 40-70% of Group II, III and IV patients and none of Group I. Conclusions: These data suggest that HRT analysis is more suitable than HRV to detect those transient alterations in autonomic control mechanisms that are likely to play a major trigger role in the genesis of malignant cardiac arrhythmias. (Heart International 2007; 3: 51-7

  8. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  9. Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Woong; Kwon, Hyuk Chan; Kim, Ki Dam; Lee, Yong Ho; Kim, Jin Mok; Kim, In Seon; Lim, Hyun Kyoon; Park, Yong Ki [Biomagnetism Research, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Kim, Doo Sang [Seoul Veterans Hospital, Seoul (Korea, Republic of); Lim, Seung Pyung [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2005-10-15

    We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was 10 fT/Hz(a) 1 Hz and 5 fT/Hz(a) 100 Hz. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  10. Current status of technology development on remote monitoring system

    International Nuclear Information System (INIS)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  11. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  12. Particulate air pollution induces arrhythmia via oxidative stress and calcium calmodulin kinase II activation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin-Bae [The Division of Cardiology, Kyung Hee University College of Medicine, 1 Hoegi-dong, Dongdaemun-Gu, Seoul (Korea, Republic of); Kim, Changsoo [The Department of Preventive Medicine, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Choi, Eunmi [Cardiovascular Research Institute and Severance Biomedical Science Institute, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Park, Sanghoon; Park, Hyelim; Pak, Hui-Nam; Lee, Moon-Hyoung [The Division of Cardiology, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Shin, Dong Chun [The Department of Preventive Medicine, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Hwang, Ki-Chul [Cardiovascular Research Institute and Severance Biomedical Science Institute, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); The Division of Cardiology, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Brain Korea 21 Project for Medical Science, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of); Joung, Boyoung, E-mail: cby6908@yuhs.ac [The Division of Cardiology, Yonsei University College of Medicine, 250 Seungsanno, Seodaemun-gu, Seoul (Korea, Republic of)

    2012-02-15

    Ambient particulate matter (PM) can increase the incidence of arrhythmia. However, the arrhythmogenic mechanism of PM is poorly understood. This study investigated the arrhythmogenic mechanism of PM. In Sprague–Dawley rats, QT interval was increased from 115.0 ± 14.0 to 142.1 ± 18.4 ms (p = 0.02) after endotracheal exposure of DEP (200 μg/ml for 30 min, n = 5). Ventricular premature contractions were more frequently observed after DEP exposure (100%) than baseline (20%, p = 0.04). These effects were prevented by pretreatment of N-acetylcysteine (NAC, 5 mmol/L, n = 3). In 12 Langendorff-perfused rat hearts, DEP infusion of 12.5 μg/ml for 20 min prolonged action potential duration (APD) at only left ventricular base increasing apicobasal repolarization gradients. Spontaneous early afterdepolarization (EAD) and ventricular tachycardia (VT) were observed in 8 (67%) and 6 (50%) hearts, respectively, versus no spontaneous triggered activity or VT in any hearts before DEP infusion. DEP-induced APD prolongation, EAD and VT were successfully prevented with NAC (5 mmol/L, n = 5), nifedipine (10 μmol/L, n = 5), and active Ca{sup 2+}/calmodulin-dependent protein kinase II (CaMKII) blockade, KN 93 (1 μmol/L, n = 5), but not by thapsigargin (200 nmol/L) plus ryanodine (10 μmol/L, n = 5) and inactive CaMKII blockade, KN 92 (1 μmol/L, n = 5). In neonatal rat cardiomyocytes, DEP provoked ROS generation in dose dependant manner. DEP (12.5 μg/ml) induced apoptosis, and this effect was prevented by NAC and KN 93. Thus, this study shows that in vivo and vitro exposure of PM induced APD prolongation, EAD and ventricular arrhythmia. These effects might be caused by oxidative stress and CaMKII activation. -- Highlights: ► The ambient PM consistently prolonged repolarization. ► The ambient PM induced triggered activity and ventricular arrhythmia. ► These effects were prevented by antioxidants, I{sub CaL} blockade and CaMKII blockade. ► The ambient PM can induce

  13. An automated neutron monitor maintenance system

    International Nuclear Information System (INIS)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-01-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  14. Integrated environmental monitoring and information system

    International Nuclear Information System (INIS)

    Klinda, J.; Lieskovska, Z.

    1998-01-01

    The concept of the environmental monitoring within the territory of the Slovak Republic and the concept of the integrated environmental information system of the Slovak Republic were accepted and confirmed by the Government Order No. 449/1992. The state monitoring system covering the whole territory of Slovakia is the most important and consists of 13 Partial Monitoring Systems (PMSs). List of PMSs is included. The listed PMSs are managed according to the concept of the Sectoral Information System (SIS) of the Ministry of the Environment of the Slovak Republic (MESR) which was established by the National Council Act No. 261/1995 Coll. on the SIS. The SIS consists of 18 subsystems which are listed. The overviews of budget of PMSs as well as of environmental publications and periodicals of the MESR are included

  15. Respiratory sinus arrhythmia responses to cognitive tasks : effects of task factors and RSA indices

    NARCIS (Netherlands)

    Overbeek, T.; Boxtel, van Anton; Westerink, J.H.D.M.

    2014-01-01

    Many studies show that respiratory sinus arrhythmia (RSA) decreases while performing cognitive tasks. However, there is uncertainty about the role of contaminating factors such as physical activity and stress-inducing task variables. Different methods to quantify RSA may also contribute to variable

  16. Respiratory sinus arrhythmia responses to cognitive tasks: Effects of task factors and RSA indices

    NARCIS (Netherlands)

    Overbeek, T.J.M.; van Boxtel, A.; Westerink, J.H.D.M.

    2014-01-01

    Many studies show that respiratory sinus arrhythmia (RSA) decreases while performing cognitive tasks. However, there is uncertainty about the role of contaminating factors such as physical activity and stress-inducing task variables. Different methods to quantify RSA may also contribute to variable

  17. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  18. Current and Emerging Uses of Insertable Cardiac Monitors: Evaluation of Syncope and Monitoring for Atrial Fibrillation.

    Science.gov (United States)

    Tomson, Todd T; Passman, Rod

    Insertable cardiac monitors (ICMs) have provided clinicians with a superb tool for assessing infrequent or potentially asymptomatic arrhythmias. ICMs have shown their usefulness in the evaluation of unexplained syncope, providing high diagnostic yields in a cost-effective manner. While unexplained syncope continues to be the most common reason for their use, ICMs are increasingly being used for the monitoring of atrial fibrillation (AF). Recent trials have demonstrated that a substantial proportion of patients with cryptogenic stroke have AF detected only by the prolonged monitoring provided by ICMs. A particularly promising and emerging use for ICMs is in the management of anticoagulation in patients with known paroxysmal AF. The introduction in recent years of ICMs with automatic AF detection algorithms and continuous remote monitoring in combination with novel oral anticoagulants have opened the door for targeted anticoagulation guided by remote monitoring, a strategy that has recently shown promise in pilot studies of this technique. While further research is needed before official recommendations can be given, this use of ICMs opens exciting new possibilities for personalized medicine that could potentially reduce bleeding risk and improve quality of life in patients with atrial fibrillation.

  19. Structure health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok

    2003-01-01

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  20. Structural health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)

    2003-07-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  1. Structure health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok [Smart Measurment Group. Korea Resarch Institute of Standards and Science, Saejeon (Korea, Republic of)

    2003-05-15

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  2. Structural health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok

    2003-01-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  3. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  4. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  5. Modification of GNPS environment radiation monitoring network system

    International Nuclear Information System (INIS)

    Jiang Lili; Cao Chunsheng

    1999-01-01

    GNPS Environment Radiation Continuous Monitoring System (KRS), the only real time on-line system of site radiation monitoring, was put into service in 1993 prior to the first loading the the plant. It is revealed through several years of operation that this system has some deficiencies such as inadequate real time monitoring means, no figure and diagram display function on the central computer, high failures, frequent failure warning signals, thus making the availability of the system at a low level. In recent years, with the rapid development of computer network technology and increasingly strict requirements on the NPP environment protection raised by the government and public, KRS modification had become necessary and urgent. In 1996, GNPS carried out modification work on the measuring geometry condition of γ radiation monitoring sub-station and lightening protection. To enhance the functions of real time monitoring and data auto-processing, further modification of the system was made in 1998, including the update of the software and hardware of KRS central processor, set-up of system computer local network and database. In this way, the system availability and monitoring quality are greatly improved and effective monitoring and analysis means are provided for gaseous release during normal operation and under accident condition

  6. Project W-420 stack monitoring system upgrades

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420

  7. Mechanisms and Clinical Management of Ventricular Arrhythmias following Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Daniel H. Wolbrom

    2016-01-01

    Full Text Available Nonpenetrating, blunt chest trauma is a serious medical condition with varied clinical presentations and implications. This can be the result of a dense projectile during competitive and recreational sports but may also include other etiologies such as motor vehicle accidents or traumatic falls. In this setting, the manifestation of ventricular arrhythmias has been observed both acutely and chronically. This is based on two entirely separate mechanisms and etiologies requiring different treatments. Ventricular fibrillation can occur immediately after chest wall injury (commotio cordis and requires rapid defibrillation. Monomorphic ventricular tachycardia can develop in the chronic stage due to underlying structural heart disease long after blunt chest injury. The associated arrhythmogenic tissue may be complex and provides the necessary substrate to form a reentrant VT circuit. Ventricular tachycardia in the absence of overt structural heart disease appears to be focal in nature with rapid termination during ablation. Regardless of the VT mechanism, patients with recurrent episodes, despite antiarrhythmic medication in the chronic stage following blunt chest injury, are likely to require ablation to achieve VT control. This review article will describe the mechanisms, pathophysiology, and treatment of ventricular arrhythmias that occur in both the acute and chronic stages following blunt chest trauma.

  8. Reliability of operating WWER monitoring systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.

    1996-01-01

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs

  9. Reliability of operating WWER monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.

    1997-12-31

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.

  10. Respiratory Sinus Arrhythmia: A Transdiagnostic Biomarker of Emotion Dysregulation and Psychopathology

    Science.gov (United States)

    Beauchaine, Theodore P.

    2015-01-01

    In the past two decades, respiratory sinus arrhythmia (RSA)—an index of parasympathetic nervous system (PNS)-mediated cardiac control—has emerged as a reliable peripheral biomarker of emotion regulation (ER). Reduced RSA and excessive RSA reactivity (i.e., withdrawal) to emotional challenge are observed consistently among individuals with poor ER capabilities, including those with various forms of internalizing and externalizing psychopathology, and those with specific psychopathological syndromes, including anxiety, phobias, attention problems, autism, callousness, conduct disorder, depression, non-suicidal self-injury, panic disorder, and trait hostility. Emerging evidence suggests that low RSA and excessive RSA reactivity index poor ER because they are downstream peripheral markers of prefrontal cortex (PFC) dysfunction. Poorly modulated inhibitory efferent pathways from the medial PFC to the PNS result in reduced RSA and excessive RSA reactivity. According to this perspective, RSA is a non-invasive proxy for poor executive control over behavior, which characterizes most forms of psychopathology. PMID:25866835

  11. Oxidized CaMKII (Ca2+/Calmodulin-Dependent Protein Kinase II) Is Essential for Ventricular Arrhythmia in a Mouse Model of Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Wang, Qiongling; Quick, Ann P; Cao, Shuyi; Reynolds, Julia; Chiang, David Y; Beavers, David; Li, Na; Wang, Guoliang; Rodney, George G; Anderson, Mark E; Wehrens, Xander H T

    2018-04-01

    Duchenne muscular dystrophy patients are prone to ventricular arrhythmias, which may be caused by abnormal calcium (Ca 2+ ) homeostasis and elevated reactive oxygen species. CaMKII (Ca 2+ /calmodulin-dependent protein kinase II) is vital for normal Ca 2+ homeostasis, but excessive CaMKII activity contributes to abnormal Ca 2+ homeostasis and arrhythmias in cardiomyocytes. Reactive oxygen species induce CaMKII to become autonomously active. We hypothesized that genetic inhibition of CaMKII oxidation (ox-CaMKII) in a mouse model of Duchenne muscular dystrophy can alleviate abnormal Ca 2+ homeostasis, thus, preventing ventricular arrhythmia. The objective of this study was to test if selective loss of ox-CaMKII affects ventricular arrhythmias in the mdx mouse model of Duchenne muscular dystrophy. 5-(6)-Chloromethyl-2,7-dichlorodihydrofluorescein diacetate staining revealed increased reactive oxygen species production in ventricular myocytes isolated from mdx mice, which coincides with elevated ventricular ox-CaMKII demonstrated by Western blotting. Genetic inhibition of ox-CaMKII by knockin replacement of the regulatory domain methionines with valines (MM-VV [CaMKII M281/282V]) prevented ventricular tachycardia in mdx mice. Confocal calcium imaging of ventricular myocytes isolated from mdx :MM-VV mice revealed normalization of intracellular Ca 2+ release events compared with cardiomyocytes from mdx mice. Abnormal action potentials assessed by optical mapping in mdx mice were also alleviated by genetic inhibition of ox-CaMKII. Knockout of the NADPH oxidase regulatory subunit p47 phox normalized elevated ox-CaMKII, repaired intracellular Ca 2+ homeostasis, and rescued inducible ventricular arrhythmias in mdx mice. Inhibition of reactive oxygen species or ox-CaMKII protects against proarrhythmic intracellular Ca 2+ handling and prevents ventricular arrhythmia in a mouse model of Duchenne muscular dystrophy. © 2018 American Heart Association, Inc.

  12. The arrangement of deformation monitoring project and analysis of monitoring data of a hydropower engineering safety monitoring system

    Science.gov (United States)

    Wang, Wanshun; Chen, Zhuo; Li, Xiuwen

    2018-03-01

    The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.

  13. Radiation monitoring of nuclear census intelligent data management and mobile monitoring data acquisition system

    International Nuclear Information System (INIS)

    Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo

    2014-01-01

    The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)

  14. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  15. Arrhythmias After Tetralogy of Fallot Repair

    Science.gov (United States)

    Folino, Antonio Franco; Daliento, Luciano

    2005-01-01

    Tetralogy of Fallot is the most common cyanotic congenital heart disease, with a good outcome after total surgical correction. In spite of a low perioperative mortality and a good quality of life, late sudden death remains a significant clinical problem, mainly related to episodes of sustained ventricular tachycardia and ventricular fibrillation. Fibro-fatty substitution around infundibular resection, intraventricular septal scar, and patchy myocardial fibrosis, may provide anatomical substrates of abnormal depolarization and repolarization causing reentrant ventricular arrhythmias. Several non-invasive indices based on classical examination such as ECG, signal-averaging ECG, and echocardiography have been proposed to identify patients at high risk of sudden death, with hopeful results. In the last years other more sophisticated invasive and non-invasive tools, such as heart rate variability, electroanatomic mapping and cardiac magnetic resonance added a relevant contribution to risk stratification. Even if each method per se is affected by some limitations, a comprehensive multifactorial clinical and investigative examination can provide an accurate risk evaluation for every patient. PMID:16943881

  16. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  17. Hybrid Wireless Hull Monitoring System for Naval Combat Vessels

    Science.gov (United States)

    2010-03-01

    Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system

  18. Radiation monitoring system in medical facilities

    International Nuclear Information System (INIS)

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  19. Brief Report: Social Skills, Internalizing and Externalizing Symptoms, and Respiratory Sinus Arrhythmia in Autism

    Science.gov (United States)

    Neuhaus, Emily; Bernier, Raphael; Beauchaine, Theodore P.

    2014-01-01

    Theoretical and empirical models describe respiratory sinus arrhythmia (RSA) as a peripheral biomarker of emotion regulation and social competence. Recent findings also link RSA to individual differences in social functioning within autism spectrum disorder (ASD). However, associations between RSA and symptoms of internalizing/externalizing…

  20. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  1. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  2. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  3. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-01-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs

  4. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  5. Low frequency of cardniac arrhythmias and lack of structural heart disease in medically-naïve acromegaly patients: a prospective study at baseline and after 1 year of somatostatin analogs treatment.

    Science.gov (United States)

    Warszawski, Leila; Kasuki, Leandro; Sá, Rodrigo; Dos Santos Silva, Cintia Marques; Volschan, Isabela; Gottlieb, Ilan; Pedrosa, Roberto Coury; Gadelha, Mônica R

    2016-12-01

    The incidence of arrhythmias may be increased in acromegaly, but the pathophysiologic mechanisms involved are still unclear, and it has never been correlated with structural heart changes analyzed by the gold-standard method cardiac magnetic resonance (CMR). Evaluate the frequency of arrhythmias in drug-naïve acromegaly patients at baseline and after 1 year of somatostatin analogs (SA) treatment and to correlate the occurrence of arrhythmias with the presence of structural heart changes. Consecutive drug-naïve acromegaly patients were recruited. The occurrence of arrhythmias and structural heart changes were studied through 24-h Holter and CMR, respectively, at baseline and after 1-year SA treatment. Thirty-six patients were studied at baseline and 28 were re-evaluated after 1 year of SA treatment. There were 13 females and median age was 48 years (20-73 years). Nine patients (32 %) were controlled after treatment. No sustained arrhythmias were reported in the 24-h Holter. No arrhythmia-related symptoms were observed. Only two patients presented left ventricular hypertrophy and three patients presented fibrosis at baseline. There was no correlation of the left ventricular mass with the number of episodes of arrhythmias and they were not more prevalent in the patients presenting cardiac fibrosis. We found no sustained arrhythmias and a lack of arrhythmia-related symptoms at baseline and after 1 year of SA treatment in a contemporary cohort of acromegaly patients that also present a low frequency of structural heart changes, indicating that these patients may have a lower frequency of heart disease than previously reported.

  6. Monitoring support system for nuclear power plant

    International Nuclear Information System (INIS)

    Higashikawa, Yuichi; Kubota, Rhuji; Tanaka, Keiji; Takano, Yoshiyuki

    1996-01-01

    The nuclear power plants in Japan reach to 49 plants and supply 41.19 million kW in their installed capacities, which is equal to about 31% of total electric power generation and has occupied an important situation as a stable energy supplying source. As an aim to keeping safe operation and working rate of the power plants, various monitoring support systems using computer technology, optical information technology and robot technology each advanced rapidly in recent year have been developed to apply to the actual plants for a plant state monitoring system of operators in normal operation. Furthermore, introduction of the emergent support system supposed on accidental formation of abnormal state of the power plants is also investigated. In this paper, as a monitoring system in the recent nuclear power plants, design of control panel of recent central control room, introduction to its actual plant and monitoring support system in development were described in viewpoints of improvement of human interface, upgrade of sensor and signal processing techniques, and promotion of information service technique. And, trend of research and development of portable miniature detector and emergent monitoring support system are also introduced in a viewpoint of labor saving and upgrade of the operating field. (G.K.)

  7. Beacon-Colss core monitoring system application and benefits

    International Nuclear Information System (INIS)

    Boyd, W.A.; Yoon, T.Y.

    2005-01-01

    Westinghouse and KNFC are creating an upgraded core monitoring system by merging the BEACON system (best estimate analyzer for core operation-nuclear) and COLSS (core operating limit supervisory system) into an integrated product. Although both BEACON and COLSS are core monitoring systems that have been in operation at many plants for a number of years, they each have some features and capabilities that are not in the other. Therefore it has been decided to incorporate portions of COLSS into the beacon system to create an optional level to support core monitoring applications on selected combustion engineering (C-E) designed plants. This optional level in the beacon system will be called BEACON-COLSS and will allow the beacon system to monitor the LCO's and Tech Spec limits at CE plants that currently use COLSS. This paper will present the structure of the new core monitoring system and the benefits it achieves for current COLSS plants, i.e., CE plants in the US and KSNP (Korean standard nuclear power plant). (authors)

  8. Applications for cyber security - System and application monitoring

    International Nuclear Information System (INIS)

    Marron, J. E.

    2006-01-01

    Standard network security measures are adequate for defense against external attacks. However, many experts agree that the greater threat is from internal sources. Insiders with malicious intentions can change controller instructions, change alarm thresholds, and issue commands to equipment which can damage equipment and compromise control system integrity. In addition to strict physical security the state of the system must be continually monitored. System and application monitoring goes beyond the capabilities of network security appliances. It will include active processes, operating system services, files, network adapters and IP addresses. The generation of alarms is a crucial feature of system and application monitoring. The alarms should be integrated to avoid the burden on operators of checking multiple locations for security violations. Tools for system and application monitoring include commercial software, free software, and ad-hoc tools that can be easily created. System and application monitoring is part of a 'defense-in-depth' approach to a control network security plan. Layered security measures prevent an individual security measure failure from being exploited into a successful security breach. Alarming of individual failures is essential for rapid isolation and correction of single failures. System and application monitoring is the innermost layer of this defense strategy. (authors)

  9. Monitoring of low level environmental gamma exposure by the centralized radiation monitoring system

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo; Obata, Kazuichi; Kokubu, Morinobu; Itoh, Naoji

    1981-07-01

    In the Japan Atomic Energy Research Institute (JAERI), a centralized automatic radiation monitoring system developed 20 years ago has recently been improved to monitor low level gamma radiation more accurately in normal operation of the nuclear facilities and to detect abnormal radioactive releases more effectively. The present state of the system is described. This system puts together environmental monitoring data such as gamma exposure rate (20 points), radioactive concentration in the air (4 points) and in water (2 drains), and meteorological items (14 including wind directions, wind speeds, solar radiation and air temperatures at a observation tower of 40 m height). Environmental monitoring around the JAERI site is carried out effectively using the system. Data processing system consists of a central processing unit, a magnetic disk, a magnetic tape, a line printer and a console typewriter. The data at respective monitoring points are transmitted to the central monitoring room by wireless or telephone line. All data are printed out and field in magnetic disk and magnetic tape every 10 minutes. When the emergency levels are exceeded, however, the data are automatically output on a line printer every 2 minute. This system can distinguish very low gamma exposure due to gaseous effluents, about 1 mR/y, from the background. Even in monthly exposures, calculated values based on the data of release amount and meteorology are in good agreement with the measured ones. (author)

  10. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  11. A radiation monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.

    1974-01-01

    Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)

  12. Monitoring Distributed Real-Time Systems: A Survey and Future Directions

    Science.gov (United States)

    Goodloe, Alwyn E.; Pike, Lee

    2010-01-01

    Runtime monitors have been proposed as a means to increase the reliability of safety-critical systems. In particular, this report addresses runtime monitors for distributed hard real-time systems. This class of systems has had little attention from the monitoring community. The need for monitors is shown by discussing examples of avionic systems failure. We survey related work in the field of runtime monitoring. Several potential monitoring architectures for distributed real-time systems are presented along with a discussion of how they might be used to monitor properties of interest.

  13. [Silent myocardial ischemia and exercise-induced arrhythmia detected by the exercise test in the total health promotion plan (THP)].

    Science.gov (United States)

    Iwane, M; Shibe, Y; Itoh, K; Kinoshita, F; Kanagawa, Y; Kobayashi, M; Mugitani, K; Ohta, M; Ohata, H; Yoshikawa, A; Ikuta, Z; Nakamura, Y; Mohara, O

    2001-03-01

    We investigated the prevalence and characteristics of ischemic heart disease especially silent myocardial ischemia (SMI) and arrhythmia in need of careful observation in the exercise stress tests in the Total Health Promotion Plan (THP), which was conducted between 1994-96 for the purpose of measuring cardiopulmonary function. All workers (n = 4,918, 4,426 males) aged 18-60 yr old in an occupational field were studied. Exercise tests with an ergometer were performed by the LOPS protocol, in which the maximal workload was set up as a presumed 70-80% maximal oxygen intake, or STEP (original multistage protocol). ECG changes were evaluated with a CC5 lead. Two hundred and fifteen people refused the study because of a common cold, lumbago and so on. Of 4,703 subjects, 17 with abnormal rest ECG and 19 with probable anginal pain were excluded from the exercise tests. Of 4,667 who underwent the exercise test, 37 (0.79%) had ischemic ECG change, and 155 (3.32%) had striking arrhythmia. These 228 subjects then did a treadmill exercise test with Bruce protocol. Twenty-two (0.47% of 4,703) showed positive ECG change, 9 (0.19%) of 22 had abnormal findings on a 201Tl scan. 8 (0.17%) were diagnosed as SMI (Cohn I), in which the prevalence of hypertension, hyperlipidemia, diabetes mellitus, smoker and positive familial history of ischemic heart disease was greater than that of all subjects. In a 15-30 month follow up, none has developed cardiac accidents. Exercise-induced arrhythmia was detected in 11 (0.23%) subjects. Four were non-sustained ventricular tachycardia without any organic disease, 4 were ventricular arrhythmia based on cardiomyopathy detected by echocardiography, 2 were atrial fibrillation and another was WPW syndrome. It is therefore likely that the ergometer exercise test in THP was effective in preventing sudden death caused by ischemic heart disease or striking arrhythmia.

  14. Automated Cryocooler Monitor and Control System Software

    Science.gov (United States)

    Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad

    2011-01-01

    This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

  15. Safeguards equipment of the future: Integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors

  16. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  17. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  18. Propose Reactor Control and Monitoring System for RTP

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Izhar Abu Hussin; Mohd Idris Taib; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha

    2011-01-01

    Reactor control and monitoring system is a one of the important features used in reactor. The control and monitoring must come together to provide safety, excellent performance and reliable in nuclear reactor technology application. Objectives of this technical paper are to design and propose reactor control system and reactor monitoring system in Research Reactor (RTP) for Reactor Upgrading Project. (author)

  19. Water monitoring and its information management system in China; Chugoku ni okeru suishitsu monitoring to joho kanri system

    Energy Technology Data Exchange (ETDEWEB)

    Quan, H.

    1996-01-10

    This paper summarizes the water monitoring system (WMS) in China applied mainly to surface water and operated within the competence of the Environmental Protection Agency. The WMS consists of a national water monitoring network and a water information system that monitors surface water periodically. The WMS comprises water monitoring stations classified from class 1 to class 4, which are located in 2,222 locations. Stations from class 1 to class 3 are operated by using computers, but class 4 stations are still incapable to use floppy disks to perform information transmission. When an information management system is completed at the China-Japan Friendship Environmental Protection Center being constructed by gratis assistance from the Japanese Government, transmission of water quality data will become possible by means of the cable line system in addition to the table system and the floppy system. The water quality data are published to general people in the forms of Chinese gazette for the environmental conditions, the environment yearbook, and the reports on environmental quality. However, the more important is to publish more publications to make people aware of the actual state of water pollution and have them cooperate in environment preservation. 4 refs., 1 fig.

  20. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  1. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  2. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  3. Outcome for Fetuses with Prenatally Detected Congenital Heart Disease and Cardiac Arrhythmias in Taiwan

    Directory of Open Access Journals (Sweden)

    Sheng-Mou Hsiao

    2007-01-01

    Conclusion: Outcome for fetuses with prenatally detected CHD remains poor, with the prognosis negatively influenced by the presence of complex heart defects as well as extracardiac and chromosomal anomalies. However, prognosis is good for fetuses with cardiac arrhythmia, except with long QT syndrome or hydrops fetalis.

  4. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  5. Atrial Arrhythmias in Obstructive Sleep Apnea: Underlying Mechanisms and Implications in the Clinical Setting

    Directory of Open Access Journals (Sweden)

    David Filgueiras-Rama

    2013-01-01

    Full Text Available Obstructive sleep apnea (OSA is a common disorder characterized by repetitive interruption of ventilation during sleep caused by recurrent upper airway collapse, which leads to intermittent hypoxia. The disorder is commonly undiagnosed despite its relationship with substantial cardiovascular morbidity and mortality. Moreover, the effects of the disorder appear to be particularly dangerous in young subjects. In the last decade, substantial clinical evidence has identified OSA as independent risk factor for both bradyarrhythmias and tachyarrhythmias. To date the mechanisms leading to such arrhythmias have not been completely understood. However, recent data from animal models and new molecular analyses have increased our knowledge of the field, which might lead to future improvement in current therapeutic strategies mainly based on continuous positive airway pressure. This paper aims at providing readers a brief and specific revision of current knowledge about the mechanisms underlying atrial arrhythmias in OSA and their clinical and therapeutic implications.

  6. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing.......We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  7. Operational readiness of filtered air discharge monitoring systems

    International Nuclear Information System (INIS)

    Lafortune, J.F.; Jamieson, T.J.

    1993-08-01

    An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report

  8. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  9. Smart health monitoring systems: an overview of design and modeling.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  10. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  11. Radiation monitoring system based on Internet

    International Nuclear Information System (INIS)

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  12. An Automated Platform for Assessment of Congenital and Drug-Induced Arrhythmia with hiPSC-Derived Cardiomyocytes

    Directory of Open Access Journals (Sweden)

    Wesley L. McKeithan

    2017-10-01

    Full Text Available The ability to produce unlimited numbers of human induced pluripotent stem cell derived cardiomyocytes (hiPSC-CMs harboring disease and patient-specific gene variants creates a new paradigm for modeling congenital heart diseases (CHDs and predicting proarrhythmic liabilities of drug candidates. However, a major roadblock to implementing hiPSC-CM technology in drug discovery is that conventional methods for monitoring action potential (AP kinetics and arrhythmia phenotypes in vitro have been too costly or technically challenging to execute in high throughput. Herein, we describe the first large-scale, fully automated and statistically robust analysis of AP kinetics and drug-induced proarrhythmia in hiPSC-CMs. The platform combines the optical recording of a small molecule fluorescent voltage sensing probe (VoltageFluor2.1.Cl, an automated high throughput microscope and automated image analysis to rapidly generate physiological measurements of cardiomyocytes (CMs. The technique can be readily adapted on any high content imager to study hiPSC-CM physiology and predict the proarrhythmic effects of drug candidates.

  13. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  14. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  15. Monitoring system in reactor dry well

    International Nuclear Information System (INIS)

    Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.

    1991-01-01

    A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)

  16. Monitoring system for OpenPBS environment

    Energy Technology Data Exchange (ETDEWEB)

    Kolosov, V. [ITEP, Moscow (Russian Federation)]. E-mail: victor.kolosov@itep.ru; Lublev, Y. [ITEP, Moscow (Russian Federation); Makarychev, S. [ITEP, Moscow (Russian Federation)

    2004-11-21

    The OpenPBS batch system is widely used in the HEP community. The Open PBS package has a set of tools to check the current status of the system. This information is useful, but it is not sufficient enough for resource accounting and planning. As a solution for this problem, we developed a monitoring system which parses the logfiles from OpenPBS and stores the information into a SQL database (PostgreSQL). This allows us to analyze the data in many different ways using SQL queries. The system was used in ITEP during the last two years for batch farm monitoring.

  17. Economic analysis of condition monitoring systems for offshore wind turbine sub-systems

    DEFF Research Database (Denmark)

    May, Allan; MacMillan, David; Thöns, Sebastian

    2015-01-01

    The use of condition monitoring systems on offshore wind turbines has increased dramatically in recent times. However, their use is mostly restricted to vibration based monitoring systems for the gearbox, generator and drive train. A survey of commercially available condition monitoring systems...... year life cycle. The model uses Hidden Markov Models to represent both the actual system state and the observed condition monitoring state. The CM systems are modelled to include reduced failure types, false alarms, detection rates and 6 month failure warnings. The costs for system failures are derived...... and their associated costs has been completed for the blades, drive train, tower and foundation. This paper considers what value can be obtained from integrating these additional systems into the maintenance plan. This is achieved by running simulations on an operations and maintenance model for a wind farm over a 20...

  18. A blade deflection monitoring system

    DEFF Research Database (Denmark)

    2017-01-01

    A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...

  19. Wide-area, real-time monitoring and visualization system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  20. Body surface mounted biomedical monitoring system using Bluetooth.

    Science.gov (United States)

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.

  1. RFID and IOT for Attendance Monitoring System

    Directory of Open Access Journals (Sweden)

    Dedy Irawan Joseph

    2018-01-01

    Full Text Available In recent years, RFID technology has been widely used in various sectors, such as in-education, transportation, agriculture, animal husbandry, store sales and other sectors. RFID utilization in education is student attendance monitoring system, by using Internet of Things (IoT and Cloud technology, it will produce a real time attendance monitoring system that can be accessed by various parties, such as lecturer, campus administration and parents. With this monitoring system if there are students who are not present can be immediately discovered and can be taken immediate action and the learning process can run smoothly.

  2. A New Environmental Monitoring System For Silkworm Incubators

    OpenAIRE

    Alejandra Duque-Torres; Juan Ruiz-Rosero; Gesille Zambrano-Gonzalez; Martha Almanza-Pinzon; Oscar Mauricio Caicedo Rendon; Gustavo Ramirez-Gonzalez

    2018-01-01

    A newly Monitoring Environmental Conditions System is proposed based on Raspberry-Pi. This proposal monitors the temperature, humidity, and luminosity in a silkworm incubator. The monitoring data are collected and save in the cloud for the subsequent analysis. The monitoring environmental system is based on Raspberry Pi due to capabilities, features, and low cost. The preliminary tests were realized in a real scenery and the results demonstrating its reliability.

  3. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  4. ZPR-9 airborne plutonium monitoring system

    International Nuclear Information System (INIS)

    Rusch, G.K.; McDowell, W.P.; Knapp, W.G.

    1975-01-01

    An airborne plutonium monitoring system which is installed in the ZPR-9 (Zero Power Reactor No. 9) facility at Argonne National Laboratory is described. The design and operational experience are discussed. This monitoring system utilizes particle size and density discrimination, alpha particle energy discrimination, and a background-subtraction techique operating in cascade to separate airborne-plutonium activity from other, naturally occurring, airborne activity. Relatively high sensitivity and reliability are achieved

  5. Coping with Feelings

    Medline Plus

    Full Text Available ... Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & ... The Impact of Congenital Heart Defects Understand Your Risk for Congenital Heart Defects Symptoms & Diagnosis of Congenital ...

  6. Communicating with Professionals

    Medline Plus

    Full Text Available ... Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & ... The Impact of Congenital Heart Defects Understand Your Risk for Congenital Heart Defects Symptoms & Diagnosis of Congenital ...

  7. Coping with Feelings

    Medline Plus

    Full Text Available ... Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & Treatment of Arrhythmia Arrhythmia ... Understand Your Risk for Congenital Heart Defects Symptoms & Diagnosis of Congenital Heart Defects Care & Treatment for Congenital ...

  8. Communicating with Professionals

    Medline Plus

    Full Text Available ... Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & Treatment of Arrhythmia Arrhythmia ... Understand Your Risk for Congenital Heart Defects Symptoms & Diagnosis of Congenital Heart Defects Care & Treatment for Congenital ...

  9. Communicating with Professionals

    Medline Plus

    Full Text Available ... Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & Treatment of Arrhythmia Arrhythmia Tools & Resources Cholesterol About Cholesterol HDL, LDL & Triglycerides Causes of High Cholesterol How To Get Your Cholesterol ...

  10. Coping with Feelings

    Medline Plus

    Full Text Available ... Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & Treatment of Arrhythmia Arrhythmia Tools & Resources Cholesterol About Cholesterol HDL, LDL & Triglycerides Causes of High Cholesterol How To Get Your Cholesterol ...

  11. IDEA-system - a new computer based expert system for incorporation monitoring

    International Nuclear Information System (INIS)

    Doerfel, H.

    2005-01-01

    Full text: There is an increasing number of national and international recommendations and guidelines for incorporation monitoring (ICRP Publications, IAEA Safety Reports, ISO Standards, etc.). These recommendations cover different phases of incorporation monitoring and they provide general requirements for the measuring techniques, the monitoring procedures and for the procedures to evaluate intakes and doses from the monitoring results. There is, however, still a strong need for giving guidance to the dosimetrists on how to apply all the regulations properly. Thus, the EU project IDEAS was launched in order to provide general guidelines for the assessment of internal dose from incorporation monitoring data. These guidelines have recently been discussed in a virtual workshop on the internet (www.ideas-workshop.de) and they are being considered by ICRP for possible adoption in the near future. Recently, in the Karlsruhe Research Centre, a computer-based expert system has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for incorporation monitoring and internal dosimetry. The expert system gives guidance to the user with respect to: planning of monitoring (estimation of potential exposures, decision on the requirements of monitoring, definition of optimum measuring techniques and monitoring intervals); performing routine and special monitoring and evaluation of primary monitoring results. The evaluation of primary monitoring results is done according to the IDEAS guidelines in a threestage procedure according to the expected level of exposure (E = committed effective dose): standard evaluation with default or site specific parameter values (E 6 mSv). With these well-defined procedures the expert system follows the aim, that all recommendations and guidelines are applied properly and thus: internal exposures of more than 1 mSv are very likely to be detected in all situations; the results in terms of committed effective

  12. Development of the simulation monitoring system

    International Nuclear Information System (INIS)

    Kato, Katsumi; Watanabe, Tadashi; Kume, Etsuo

    2001-01-01

    Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering for the computational science research in nuclear fields. Visualization and animation processing techniques are developed for efficient understanding of simulation results. The development of the simulation monitoring system, which is used for real-time visualization of ongoing simulations or for successive visualization of calculated results, is described in this report. The standard visualization tool AVS5 or AVS/EXPRESS is used for the simulation monitoring system, and thus, this system can be utilized in various computer environments. (author)

  13. Delayed-enhancement MRI of apical hypertrophic cardiomyopathy: assessment of the intramural distribution and comparison with clinical symptoms, ventricular arrhythmias, and cine MRI

    International Nuclear Information System (INIS)

    Amano, Yasuo; Fukushima, Yoshimitsu; Kumita, Shinichiro; Takayama, Morimasa; Kitamura, Mitsunobu

    2011-01-01

    Background: Hypertrophic cardiomyopathy (HCM) is reported to show patchy midwall myocardial hyper enhancement on delayed-enhancement magnetic resonance imaging (DE-MRI). The intramural distribution of myocardial hyper enhancement and its correlation with clinical symptoms, ventricular arrhythmias, and cardiac function have not been described for symptomatic apical HCM. Purpose: To evaluate the features and significance of myocardial hyper enhancement on DE-MRI in symptomatic apical HCM. Material and Methods: Thirteen patients with symptomatic apical HCM and their 65 apical segments were investigated. Myocardial hyper enhancement and regional and global functional parameters were determined with MRI. We investigated the intramural distribution and frequencies of this myocardial hyper enhancement and compared them with the patients' clinical symptoms, the presence of ventricular arrhythmias, and cine MRI. Results: Eight (61.5%) patients with symptomatic apical HCM displayed apical myocardial hyper enhancement, and 22 (33.8%) of the 65 apical segments examined showed myocardial hyper enhancement. Of the myocardial hyper enhancement observed, 81.8% showed a subendocardial pattern.The Hyperenhanced apical myocardium had a lower percentage of systolic myocardial thickening, and was associated with serious symptoms (e.g. syncope) and ventricular arrhythmias. Conclusion: Patients with symptomatic apical HCM showed myocardial hyper enhancement involving the subendocardial layer, which might be related to regional systolic dysfunction, serious clinical symptoms, and ventricular arrhythmias

  14. Application of Video Recognition Technology in Landslide Monitoring System

    Directory of Open Access Journals (Sweden)

    Qingjia Meng

    2018-01-01

    Full Text Available The video recognition technology is applied to the landslide emergency remote monitoring system. The trajectories of the landslide are identified by this system in this paper. The system of geological disaster monitoring is applied synthetically to realize the analysis of landslide monitoring data and the combination of video recognition technology. Landslide video monitoring system will video image information, time point, network signal strength, power supply through the 4G network transmission to the server. The data is comprehensively analysed though the remote man-machine interface to conduct to achieve the threshold or manual control to determine the front-end video surveillance system. The system is used to identify the target landslide video for intelligent identification. The algorithm is embedded in the intelligent analysis module, and the video frame is identified, detected, analysed, filtered, and morphological treatment. The algorithm based on artificial intelligence and pattern recognition is used to mark the target landslide in the video screen and confirm whether the landslide is normal. The landslide video monitoring system realizes the remote monitoring and control of the mobile side, and provides a quick and easy monitoring technology.

  15. Corral Monitoring System assessment results

    International Nuclear Information System (INIS)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system

  16. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  17. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  18. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  19. An Electrical Energy Consumption Monitoring and Forecasting System

    Directory of Open Access Journals (Sweden)

    J. L. Rojas-Renteria

    2016-10-01

    Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.

  20. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  1. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  2. The relationship between ECG signs of atrial infarction and the development of supraventricular arrhythmias in patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Nielsen, F E; Andersen, H H; Gram-Hansen, P

    1992-01-01

    ECGs obtained on arrival at the hospital from 277 patients with acute myocardial infarction were analyzed retrospectively for PR displacements, which were classified as major or minor criteria for atrial infarction and related to the later occurrence of supraventricular arrhythmia in the hospital...... arrhythmias, giving odds ratios of 9.9 and 3.7, respectively. Enzyme-estimated infarct size, the occurrence of heart failure, and mortality rates did not differ in patients with or without major criteria for atrial infarction. We conclude that the occurrence of PR segment displacements on the admission ECG...

  3. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  4. Upgrade of the monitoring system of LHCb ECAL

    CERN Document Server

    Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei

    2016-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.

  5. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  6. Effects of exogenous oxygen derived free radicals on myocardial capillary permeability, vascular tone, and incidence of ventricular arrhythmias in the canine heart

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Bjerrum, P J

    1992-01-01

    The aim was to examine the effects of exogenous oxygen derived free radicals on myocardial capillary permeability for a small hydrophilic indicator, postischaemic vascular tone, and the occurrence of arrhythmias in the canine heart in vivo.......The aim was to examine the effects of exogenous oxygen derived free radicals on myocardial capillary permeability for a small hydrophilic indicator, postischaemic vascular tone, and the occurrence of arrhythmias in the canine heart in vivo....

  7. Timing and control monitor system upgrade design document. Version 4

    International Nuclear Information System (INIS)

    Brandt, J.J.

    1984-01-01

    This is a design document for the Timing and Control Monitor System Upgrade Project. This project is intended to provide a replacement system for the existing user Encoder Monitor Systems and Varian 72 Control Room computer systems. All of these systems reside at the Nevada Test Site. The function of the T and C Monitor System is to gather real-time statistics and data on user defined key variables from control, communication, data acquistion systems, and from the monitoring system itself. The control, communication, and data acquisition systems each operate separately from the monitor system. The T and C Monitor System gathers this data in order to verify the readiness of an event to begin countdown. This includes setup, verification, calibration, and peripheral services, report any failures that may occur during the countdown, verify detonation and containment, and assist reentry activities after the event

  8. Experience with neutron flux monitoring systems qualified for post-accident monitoring

    International Nuclear Information System (INIS)

    Shugars, H.G.; Miller, J.F.

    1995-01-01

    In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs

  9. Supervisory monitoring system in nuclear power plants

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Turkcan, E.

    1997-01-01

    Monitoring of a power plant is one of the essential tasks during operation and the computer-based implementations are nowadays seemingly quite mature. However, presently these are still not satisfactory enough to meet the high standards to the licensing requirements and they are mostly not truly integrated to the plant's design-based monitoring system. This is basically due to the robustness problem as the majority of the methods are not robust enough for the monitoring of the safety parameter set in a plant or intelligent supervision. Therefore, a supervisory monitoring system (SMS) in a plant is necessary to supervise the monitoring tasks: determining the objectives to be obtained and finding the means to support them. SMS deals with the changing plant status and the coordination of the information flow among the monitoring subunits. By means of these robustness and consistency in monitoring is achieved. The paper will give the guidelines of knowledge and data management techniques in a framework of robust comprehensive and coordinated monitoring which is presented as supervisory monitoring. Such a high level monitoring serves for consistent and immediate actions in fault situations while this particularly has vital importance in preventing imminent severe accidents next to the issues of recognition of the monitoring procedures for licensing and enhanced plant safety. (author). 8 refs, 5 figs

  10. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  11. Remote monitoring of VRLA batteries for telecommunications systems

    Energy Technology Data Exchange (ETDEWEB)

    Tsujikawa, Tomonobu; Matsushima, Toshio [NTT Facilities Inc., G.H.Y. Building, 2-13-1 Kita-Otsuka, Toshima-ku, Tokyo 170-0004 (Japan)

    2007-05-25

    This paper describes a remote monitoring system that can be set up in an operating center to monitor the state of valve regulated lead acid batteries (VRLA) used as a backup power supply for telecommunications. This system has a battery voltage monitoring function, a lifetime prediction function based on ambient temperature, and a discharge circuit diagnosis function. In addition, the system can be equipped with an internal resistance measurement function and an electrolyte leakage detection function to further insure power-supply reliability. Various states of batteries observed with the system are transmitted to the remote operating center by a remote monitoring function. This function enables obtaining immediate information about the condition of batteries and helps to avoid unexpected failures. (author)

  12. Cardiac cell therapy: overexpression of connexin43 in skeletal myoblasts and prevention of ventricular arrhythmias

    NARCIS (Netherlands)

    Fernandes, Sarah; van Rijen, Harold V. M.; Forest, Virginie; Evain, Stéphane; Leblond, Anne-Laure; Mérot, Jean; Charpentier, Flavien; de Bakker, Jacques M. T.; Lemarchand, Patricia

    2009-01-01

    Cell-based therapies have great potential for the treatment of cardiovascular diseases. Recently, using a transgenic mouse model Roell et al. reported that cardiac engraftment of connexin43 (Cx43)-overexpressing myoblasts in vivo prevents post-infarct arrhythmia, a common cause of death in patients

  13. Cost-effectiveness of genotyping in inherited arrhythmia syndromes: are we getting value for the money?

    NARCIS (Netherlands)

    Wilde, Arthur A. M.; Pinto, Yigal M.

    2009-01-01

    Over the last decade, the identification of the diverse genetic basis of most important inherited arrhythmia syndromes has remarkably changed our attitude toward these life-threatening diseases. Just over 10 years ago, long-QT syndrome (LQTS) was considered one disease entity, Brugada -QT syndrome

  14. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  15. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  16. Effect of sodium nitrite on ischaemia and reperfusion-induced arrhythmias in anaesthetized dogs: is protein S-nitrosylation involved?

    Directory of Open Access Journals (Sweden)

    Mária Kovács

    Full Text Available To provide evidence for the protective role of inorganic nitrite against acute ischaemia and reperfusion-induced ventricular arrhythmias in a large animal model.Dogs, anaesthetized with chloralose and urethane, were administered intravenously with sodium nitrite (0.2 µmol kg(-1 min(-1 in two protocols. In protocol 1 nitrite was infused 10 min prior to and during a 25 min occlusion of the left anterior descending (LAD coronary artery (NaNO2-PO; n = 14, whereas in protocol 2 the infusion was started 10 min prior to reperfusion of the occluded vessel (NaNO2-PR; n = 12. Control dogs (n = 15 were infused with saline and subjected to the same period of ischaemia and reperfusion. Severities of ischaemia and ventricular arrhythmias, as well as changes in plasma nitrate/nitrite (NOx levels in the coronary sinus blood, were assessed throughout the experiment. Myocardial superoxide and nitrotyrosine (NT levels were determined during reperfusion. Changes in protein S-nitrosylation (SNO and S-glutathionylation were also examined.Compared with controls, sodium nitrite administered either pre-occlusion or pre-reperfusion markedly suppressed the number and severity of ventricular arrhythmias during occlusion and increased survival (0% vs. 50 and 92% upon reperfusion. There were also significant decreases in superoxide and NT levels in the nitrite treated dogs. Compared with controls, increased SNO was found only in NaNO2-PR dogs, whereas S-glutathionylation occurred primarily in NaNO2-PO dogs.Intravenous infusion of nitrite profoundly reduced the severity of ventricular arrhythmias resulting from acute ischaemia and reperfusion in anaesthetized dogs. This effect, among several others, may result from an NO-mediated reduction in oxidative stress, perhaps through protein SNO and/or S-glutathionylation.

  17. Differential roles of two delayed rectifier potassium currents in regulation of ventricular action potential duration and arrhythmia susceptibility.

    Science.gov (United States)

    Devenyi, Ryan A; Ortega, Francis A; Groenendaal, Willemijn; Krogh-Madsen, Trine; Christini, David J; Sobie, Eric A

    2017-04-01

    Arrhythmias result from disruptions to cardiac electrical activity, although the factors that control cellular action potentials are incompletely understood. We combined mathematical modelling with experiments in heart cells from guinea pigs to determine how cellular electrical activity is regulated. A mismatch between modelling predictions and the experimental results allowed us to construct an improved, more predictive mathematical model. The balance between two particular potassium currents dictates how heart cells respond to perturbations and their susceptibility to arrhythmias. Imbalances of ionic currents can destabilize the cardiac action potential and potentially trigger lethal cardiac arrhythmias. In the present study, we combined mathematical modelling with information-rich dynamic clamp experiments to determine the regulation of action potential morphology in guinea pig ventricular myocytes. Parameter sensitivity analysis was used to predict how changes in ionic currents alter action potential duration, and these were tested experimentally using dynamic clamp, a technique that allows for multiple perturbations to be tested in each cell. Surprisingly, we found that a leading mathematical model, developed with traditional approaches, systematically underestimated experimental responses to dynamic clamp perturbations. We then re-parameterized the model using a genetic algorithm, which allowed us to estimate ionic current levels in each of the cells studied. This unbiased model adjustment consistently predicted an increase in the rapid delayed rectifier K + current and a drastic decrease in the slow delayed rectifier K + current, and this prediction was validated experimentally. Subsequent simulations with the adjusted model generated the clinically relevant prediction that the slow delayed rectifier is better able to stabilize the action potential and suppress pro-arrhythmic events than the rapid delayed rectifier. In summary, iterative coupling of

  18. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  19. Excessive exercise habits of runners as new signs of hypertension and arrhythmia.

    Science.gov (United States)

    Kim, Young-Joo; Kim, Chul-Hyun; Park, Kyoung-Min

    2016-08-15

    Excessive exercise may induce arrhythmia, and this risk is higher in middle-aged people. The study aim was to compare the exercise characteristics of middle-aged runners participating in excessive endurance exercise. The subjects of this study were 552 runners (mean age; 49.0±7.4years) without structural heart disease who performed exercise at least twice per week, had consistently exercised for at least three years, and had finished at least five marathons. The arrhythmia runner group (ARG, n=14) and normal runner group (NRG, n=538) were compared with regard to hemodynamic response, cardiorespiratory fitness level, training history, number of finished races, finishing times, and exercise habits. The mean resting systolic (134.0±15.8mmHg) and diastolic (85.8±10.9mmHg) blood pressure values indicated pre-hypertension, while the mean maximal SBP (213.7±27.4mmHg) values indicated exercise-induced hypertension. The VO2max was significantly higher and the maximal DBP was significantly lower in the ARG than in the NRG (phypertension and exercise-induced hypertension, and the ARG had higher VO2max values, greater exercise intensities, and longer training histories than the NRG. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Arrhythmias After Tetralogy of Fallot Repair

    Directory of Open Access Journals (Sweden)

    Antonio Franco Folino

    2005-10-01

    Full Text Available Tetralogy of Fallot is the most common cyanotic congenital heart disease, with a good outcome after total surgical correction. In spite of a low perioperative mortality and a good quality of life, late sudden death remains a significant clinical problem, mainly related to episodes of sustained ventricular tachycardia and ventricular fibrillation. Fibro-fatty substitution around infundibular resection, intraventricular septal scar, and patchy myocardial fibrosis, may provide anatomical substrates of abnormal depolarization and repolarization causing reentrant ventricular arrhythmias. Several non-invasive indices based on classical examination such as ECG, signal-averaging ECG, and echocardiography have been proposed to identify patients at high risk of sudden death, with hopeful results. In the last years other more sophisticated invasive and non-invasive tools, such as heart rate variability, electroanatomic mapping and cardiac magnetic resonance added a relevant contribution to risk stratification. Even if each method per se is affected by some limitations, a comprehensive multifactorial clinical and investigative examination can provide an accurate risk evaluation for every patient.

  1. Activity monitoring systems in health care

    NARCIS (Netherlands)

    Kröse, B.; van Oosterhout, T.; van Kasteren, T.; Salah, A.A.; Gevers, T.

    2011-01-01

    This chapter focuses on activity monitoring in a home setting for health care purposes. First the most current sensing systems are described, which consist of wearable and ambient sensors. Then several approaches for the monitoring of simple actions are discussed, like falls or therapies. After

  2. Geological hazard monitoring system in Georgia

    Science.gov (United States)

    Gaprindashvili, George

    2017-04-01

    Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.

  3. 10-year follow-up after radiofrequency ablation of idiopathic ventricular arrhythmias from right ventricular outflow tract

    Directory of Open Access Journals (Sweden)

    Synne Dragesund Rørvik

    2016-05-01

    Conclusions: A reduction of symptoms and use of antiarrhythmic medication, as well as an improvement in the general health perception and fitness to work after RFA of idiopathic ventricular arrhythmias can be demonstrated at ten-year follow-up.

  4. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  5. Efficient network monitoring for large data acquisition systems

    International Nuclear Information System (INIS)

    Savu, D.O.; Martin, B.; Al-Shabibi, A.; Sjoen, R.; Batraneanu, S.M.; Stancu, S.N.

    2012-01-01

    Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed realtime data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and seamlessly integrates complementary data from auxiliary tools, such as NAGIOS, information services or custom databases. A number of techniques (e.g. normalization, aggregation and data caching) were used in order to improve the user interface response time. The end result is a unified monitoring interface, for fast and uniform access to system statistics, which significantly reduced the time spent by experts for ad-hoc and post-mortem analysis. (authors)

  6. The Advanced Monitoring Systems Initiative--Performance Monitoring for DOE Environmental Remediation and Contaminant Containment

    Science.gov (United States)

    Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.

    2005-05-01

    The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and

  7. User interface design and system integration aspects of core monitoring systems

    International Nuclear Information System (INIS)

    Berg, O.; Bodal, T.; Hornaes, A.; Porsmyr, J.

    2000-01-01

    The present paper describes our experience with the SCORPIO core monitoring system using generic building blocks for the MMI and system integration. In this context the different layers of the software system are discussed starting with the communication system, interfacing of various modules (e.g. physics codes), administration of several modules and generation of graphical user interfaces for different categories of end-users. A method by which re-use of software components can make the system development and maintenance more efficient is described. Examples are given from different system installation projects. The methodology adopted is considered particularly important in the future, as it is anticipated that core monitoring systems will be expanded with new functions (e.g. information from technical specifications, procedures, noise analysis, etc). Further, efficient coupling of off-line tools for core physics calculations and on-line modules in core monitoring can pave the way for cost savings. (authors)

  8. Environmental radiation monitoring system with GPS (global positioning system)

    International Nuclear Information System (INIS)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  9. Coping with Feelings

    Medline Plus

    Full Text Available ... American Heart area Search By Zipcode Search by State SELECT YOUR LANGUAGE Español (Spanish) 繁体中文 (Traditional Chinese) ... Arrhythmia About Arrhythmia Why Arrhythmia Matters Understand Your Risk for Arrhythmia Symptoms, Diagnosis & Monitoring of Arrhythmia Prevention & ...

  10. 296-B-10 stack monitoring and sampling system annual system assessment report

    International Nuclear Information System (INIS)

    Ridge, T.M.

    1995-01-01

    B Plant Administration Manual, requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with stack 296-B-10 at B Plant. The ventilation system of WESF (Waste Encapsulation and Storage Facility) is designed to provide airflow patterns so that air movement throughout the building is from areas of lesser radioactivity to areas of greater radioactivity. All potentially contaminated areas are maintained at a negative pressure with respect to the atmosphere so that air flows into the building at all times. The exhaust discharging through the 296-B-10 stack is continuously monitored and sampled using a sampling and monitoring probe assembly located approximately 17.4 meters (57 feet) above the base of the stack. The probe assembly consists of 5 nozzles for the sampling probe and 2 nozzles to monitor the flow. The sampling and monitoring system associated with Stack 296-B-10 is functional and performing satisfactorily

  11. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  12. IDEA system - a new computer-based expert system for incorporation monitoring

    International Nuclear Information System (INIS)

    Doerfel, H.

    2007-01-01

    Recently, at the Karlsruhe Research Centre, a computer-based expert system, Internal Dose Equivalent Assessment System (IDEA System), has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for internal dosimetry. The expert system gives guidance to the user with respect to: (a) planning of monitoring, (b) performing routine and special monitoring, and (c) evaluation of primary monitoring results. The evaluation is done according to the IDEA System guidelines (Doerfel, H. et al., General guidelines for the estimation of committed effective dose from incorporation monitoring data. Research Report FZKA 7243, Research Center Karlsruhe, Karlsruhe (2006). ISSN 0947-8260.) in a three-stage procedure according to the expected level of exposure. At the first level the evaluation is performed with default or site-specific parameter values, at the second level case-specific parameter values are applied and at the third level a special evaluation is performed with individual adjustment of model parameter values. With these well-defined procedures the expert system follows the aim, in which all recommendations and guidelines are applied properly and the results in terms of committed effective and organ doses are close to the best estimate. (author)

  13. Identifying potential functional impact of mutations and polymorphisms: Linking heart failure, increased risk of arrhythmias and sudden cardiac death.

    Directory of Open Access Journals (Sweden)

    BENOIT eJAGU

    2013-09-01

    Full Text Available Researchers and clinicians have discovered several important concepts regarding the mechanisms responsible for increased risk of arrhythmias, heart failure and sudden cardiac death. One major step in defining the molecular basis of normal and abnormal cardiac electrical behaviour has been the identification of single mutations that greatly increase the risk for arrhythmias and sudden cardiac death by changing channel-gating characteristics. Indeed, mutations in several genes encoding ion channels, such as SCN5A, which encodes the major cardiac Na+ channel, have emerged as the basis for a variety of inherited cardiac arrhythmias such as long QT syndrome, Brugada syndrome, progressive cardiac conduction disorder, sinus node dysfunction or sudden infant death syndrome. In addition, genes encoding ion channel accessory proteins, like anchoring or chaperone proteins, which modify the expression, the regulation of endocytosis and the degradation of ion channel α-subunits have also been reported as susceptibility genes for arrhythmic syndromes. The regulation of ion channel protein expression also depends on a fine-tuned balance among different other mechanisms, such as gene transcription, RNA processing, post-transcriptional control of gene expression by miRNA, protein synthesis, assembly and post-translational modification and trafficking.

  14. Atrial arrhythmia in ageing spontaneously hypertensive rats: unraveling the substrate in hypertension and ageing.

    Directory of Open Access Journals (Sweden)

    Dennis H Lau

    Full Text Available BACKGROUND: Both ageing and hypertension are known risk factors for atrial fibrillation (AF although the pathophysiological contribution or interaction of the individual factors remains poorly understood. Here we aim to delineate the arrhythmogenic atrial substrate in mature spontaneously hypertensive rats (SHR. METHODS: SHR were studied at 12 and 15 months of age (n = 8 per group together with equal numbers of age-matched normotensive Wistar-Kyoto control rats (WKY. Electrophysiologic study was performed on superfused isolated right and left atrial preparations using a custom built high-density multiple-electrode array to determine effective refractory periods (ERP, atrial conduction and atrial arrhythmia inducibility. Tissue specimens were harvested for structural analysis. RESULTS: COMPARED TO WKY CONTROLS, THE SHR DEMONSTRATED: Higher systolic blood pressure (p<0.0001, bi-atrial enlargement (p<0.05, bi-ventricular hypertrophy (p<0.05, lower atrial ERP (p = 0.008, increased atrial conduction heterogeneity (p = 0.001 and increased atrial interstitial fibrosis (p = 0.006 & CD68-positive macrophages infiltration (p<0.0001. These changes resulted in higher atrial arrhythmia inducibility (p = 0.01 and longer induced AF episodes (p = 0.02 in 15-month old SHR. Ageing contributed to incremental bi-atrial hypertrophy (p<0.01 and atrial conduction heterogeneity (p<0.01 without affecting atrial ERP, fibrosis and arrhythmia inducibility. The limited effect of ageing on the atrial substrate may be secondary to the reduction in CD68-positive macrophages. CONCLUSIONS: Significant atrial electrical and structural remodeling is evident in the ageing spontaneously hypertensive rat atria. Concomitant hypertension appears to play a greater pathophysiological role than ageing despite their compounding effect on the atrial substrate. Inflammation is pathophysiologically linked to the pro-fibrotic changes in the hypertensive atria.

  15. Home-based mobile cardio-pulmonary rehabilitation consultant system.

    Science.gov (United States)

    Lee, Hsu-En; Wang, Wen-Chih; Lu, Shao-Wei; Wu, Bo-Yuan; Ko, Li-Wei

    2011-01-01

    Cardiovascular diseases are the most popular cause of death in the world recently. For postoperatives, cardiac rehabilitation is still asked to maintain at home (phase II) to improve cardiac function. However, only one third of outpatients do the exercise regularly, reflecting the difficulty for home-based healthcare: lacking of monitoring and motivation. Hence, a cardio-pulmonary rehabilitation system was proposed in this research to improve rehabilitation efficiency for better prognosis. The proposed system was built on mobile phone and receiving electrocardiograph (ECG) signal from a wireless ECG holter via Bluetooth connection. Apart from heart rate (HR) monitor, an ECG derived respiration (EDR) technique is also included to provide respiration rate (RR). Both HR and RR are the most important vital signs during exercise but only used one physiological signal recorder in this system. In clinical test, there were 15 subjects affording Bruce Task (treadmill) to simulate rehabilitation procedure. Correlation between this system and commercial product (Custo-Med) was up to 98% in HR and 81% in RR. Considering the prevention of sudden heart attack, an arrhythmia detection expert system and healthcare server at the backend were also integrated to this system for comprehensive cardio-pulmonary monitoring whenever and wherever doing the exercise.

  16. Monitoring solar-thermal systems: An outline of methods and procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, A. [New Mexico State Univ., Las Cruces, NM (United States). Southwest Technology Development Inst.

    1994-04-01

    This manual discusses the technical issues associated with monitoring solar-thermal systems. It discusses some successful monitoring programs that have been implemented in the past. It gives the rationale for selecting a program of monitoring and gives guidelines for the design of new programs. In this report, solar thermal monitoring systems are classified into three levels. For each level, the report discusses the kinds of information obtained by monitoring, the effort needed to support the monitoring program, the hardware required, and the costs involved. Ultimately, all monitoring programs share one common requirement: the collection of accurate data that characterize some aspect or aspects of the system under study. This report addresses most of the issues involved with monitoring solar thermal systems. It does not address such topics as design fundamentals of thermal systems or the relative merits of the many different technologies employed for collection of solar energy.

  17. Automated respiratory sinus arrhythmia measurement: Demonstration using executive function assessment.

    Science.gov (United States)

    Hegarty-Craver, Meghan; Gilchrist, Kristin H; Propper, Cathi B; Lewis, Gregory F; DeFilipp, Samuel J; Coffman, Jennifer L; Willoughby, Michael T

    2017-08-08

    Respiratory sinus arrhythmia (RSA) is a quantitative metric that reflects autonomic nervous system regulation and provides a physiological marker of attentional engagement that supports cognitive and affective regulatory processes. RSA can be added to executive function (EF) assessments with minimal participant burden because of the commercial availability of lightweight, wearable electrocardiogram (ECG) sensors. However, the inclusion of RSA data in large data collection efforts has been hindered by the time-intensive processing of RSA. In this study we evaluated the performance of an automated RSA-scoring method in the context of an EF study in preschool-aged children. The absolute differences in RSA across both scoring methods were small (mean RSA differences = -0.02-0.10), with little to no evidence of bias for the automated relative to the hand-scoring approach. Moreover, the relative rank-ordering of RSA across both scoring methods was strong (rs = .96-.99). Reliable changes in RSA from baseline to the EF task were highly similar across both scoring methods (96%-100% absolute agreement; Kappa = .83-1.0). On the basis of these findings, the automated RSA algorithm appears to be a suitable substitute for hand-scoring in the context of EF assessment.

  18. Best Management Practices Monitoring Guide for Stream Systems

    OpenAIRE

    Mesner, Nancy

    2011-01-01

    Best Management Practices Monitoring Guide for Stream Systems provides guidance on establishing a water quality monitoring program that will demonstrate the effectiveness of Best Management Practices (BMPs) to reduce nonpoint source pollution in stream systems.

  19. Bile acids induce arrhythmias in human atrial myocardium--implications for altered serum bile acid composition in patients with atrial fibrillation.

    Science.gov (United States)

    Rainer, Peter P; Primessnig, Uwe; Harenkamp, Sandra; Doleschal, Bernhard; Wallner, Markus; Fauler, Guenter; Stojakovic, Tatjana; Wachter, Rolf; Yates, Ameli; Groschner, Klaus; Trauner, Michael; Pieske, Burkert M; von Lewinski, Dirk

    2013-11-01

    High bile acid serum concentrations have been implicated in cardiac disease, particularly in arrhythmias. Most data originate from in vitro studies and animal models. We tested the hypotheses that (1) high bile acid concentrations are arrhythmogenic in adult human myocardium, (2) serum bile acid concentrations and composition are altered in patients with atrial fibrillation (AF) and (3) the therapeutically used ursodeoxycholic acid has different effects than other potentially toxic bile acids. Multicellular human atrial preparations ('trabeculae') were exposed to primary bile acids and the incidence of arrhythmic events was assessed. Bile acid concentrations were measured in serum samples from 250 patients and their association with AF and ECG parameters analysed. Additionally, we conducted electrophysiological studies in murine myocytes. Taurocholic acid (TCA) concentration-dependently induced arrhythmias in atrial trabeculae (14/28 at 300 µM TCA, pursodeoxycholic acid did not. Patients with AF had significantly decreased serum levels of ursodeoxycholic acid conjugates and increased levels of non-ursodeoxycholic bile acids. In isolated myocytes, TCA depolarised the resting membrane potential, enhanced Na(+)/Ca(2+) exchanger (NCX) tail current density and induced afterdepolarisations. Inhibition of NCX prevented arrhythmias in atrial trabeculae. High TCA concentrations induce arrhythmias in adult human atria while ursodeoxycholic acid does not. AF is associated with higher serum levels of non-ursodeoxycholic bile acid conjugates and low levels of ursodeoxycholic acid conjugates. These data suggest that higher levels of toxic (arrhythmogenic) and low levels of protective bile acids create a milieu with a decreased arrhythmic threshold and thus may facilitate arrhythmic events.

  20. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....