WorldWideScience

Sample records for argon plasma coagulation

  1. Argon plasma coagulation for treatment of hemorrhagic radiation gastroduodenitis

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Shu-Ji; Aoyama, Nobuo; Shirasaka, Daisuke; Inoue, Takashi; Kuroda, Kohei; Ebara, Shigeyuki; Tamura, Takao; Miyamoto, Masaki; Kasuga, Masato [Kobe Univ. (Japan). Graduate School of Medicine

    2002-01-01

    A 79-year-old man who had received radiotherapy for portal vein thrombosis due to hepatocellular carcinoma (HCC) 5 months earlier, showed progressive anemia and melena. Endoscopy on admission revealed diffuse bleeding from multiple telangiectasias on the anterior wall of the antrum and bulbus. We treated this patient with a new non-contact hemostatic method: the argon plasma coagulator (APC). The melena stopped after the first session and the hemoglobin level remained stable for 7 months. No delayed complications have been observed. Gastrointestinal bleeding from chronic radiation gastroduodenitis is rarely reported compared with radiation proctitis. This case demonstrates that APC is effective for hemostasis of diffuse bleeding from radiation gastroduodenitis, just as for radiation protitis. (author)

  2. Ablation of Barrett’s esophagus using the second-generation argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To investigate the efficacy and safety of the second-generation argon plasma coagulation (VIO APC) in ablation of Barrett’s esophagus. Methods Eighteen patients with Barrett’s esophagus (12 males, median age of 55 years, median length of 2.1 cm,1 low-grade dysplasia, 13 cases of short segment Barrett’s esophagus) received VIO APC, which was performed at a power setting of 40W and argon gas flow at 1.5-2.0 L/min, "forced" mode, in 1-3 sessions (mean 1.3). All the patients received treatment with hi...

  3. Epinephrine plus argon plasma or heater probe coagulation in ulcer bleeding

    Institute of Scientific and Technical Information of China (English)

    Ahmet Karaman; Mevlut Baskol; Sebnem Gursoy; Edip Torun; Alper Yurci; Banu Demet Ozel; Kadri Guven; Omer Ozbakir; Mehmet Yucesoy

    2011-01-01

    AIM: To compare the effectiveness of argon plasma coagulation (APC) and heater probe coagulation (HPC) in non-variceal upper gastrointestinal bleeding. METHODS: Eighty-five (18 female, 67 male) patients admitted for acute gastrointestinal bleeding due to gastric or duodenal ulcer were included in the study. Upper endoscopy was performed and HPC or APC were chosen randomly to stop the bleeding. Initial hemostasis and rebleeding rates were primary and secondary end-points of the study. RESULTS: Initial hemostasis was achieved in 97.7% (42/43) and 81% (36/42) of the APC and HPC groups, respectively (P 0.05). CONCLUSION: APC is an effective hemostatic method in bleeding peptic ulcers. Larger multicenter trials are necessary to confirm these results.

  4. Long-term outcomes of endoscopic argon plasma coagulation (APC) therapy for early esophageal cancer and precancerous lesions

    Institute of Scientific and Technical Information of China (English)

    王国清

    2013-01-01

    Objective To evaluate the long-term outcomes of endoscopic argon plasma coagulation (APC) therapy for early esophageal cancer and precancerous lesions.Methods One-hundred and seventy one cases with early esophageal cancer (intramucosal carcinoma) and precancerous lesions were treated by APC from 1994 to 2005,

  5. Ablation of Barrett's esophagus using the second-generation argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    Li Zhang; Lei Dong; Jia Liu; Xiao-lan Lu

    2009-01-01

    Objective To investigate the efficacy and safety of the second-generation argon plasma coagulation (VIO APC) in ablation of Barrett's esophagus. Methods Eighteen patients with Barrett's esophagus (12 males, median age of 55 years, median length of 2.1 cm,1 low-grade dysplasia, 13 cases of short segment Barrett's esophagus) received VIO APC, which was performed at a power setting of 40W and argon gas flow at 1. 5-2. 0 L/min, "forced" mode, in 1-3 sessions (mean 1.3). All the patients received treatment with high-dose proton pump inhibitors. The main complaints before ablation were upper abdominal pain in 12 patients (66%), sour regurgitation in 14 patients (77%), and dysphagia or odynophagia in 7 patients (38%). Two patients (11%) had esophageal hiatal hernia. Results The percentage of patients in whom ablation was endoscopically achieved proximal to the gastroesophageal junction was 77. 8%(14/18), and histologically achieved in 66. 7% (12/18). Berried glands were observed in 2 patients who had achieved endoscopic ablation, the areas of Barrett's mucosa were reduced by more than 60% in the other 4 patients. After treatment, 4 patients had transient retrosternal pain and 3 patients had mild epigastric discomfort. One patient had small amounts of hemorrhage during the process, and it ceased after norepinephrine and thrombosin were administered through endoscope biopsy channel. No esophageal stricture or other severe adverse events was observed. During 11.8 (4-15) months' follow-up, the patients who had achieved the complete ablation had no evidence of relapse of Barrett's esophagus. Conclusion VIO APC with a relatively low power setting can effectively ablate the Barrett's mucosa with special intestinal metaplasia when standard APC has been done. No severe adverse events were observed. Long-term follow-up is needed to assess cancer prevention and the durability of the neo-squamous epithelium.

  6. Adrenaline Injection Plus Argon Plasma Coagulation versus Adrenaline Injection Plus Hemoclips for Treating High-Risk Bleeding Peptic Ulcers: A Prospective, Randomized Trial

    Directory of Open Access Journals (Sweden)

    Seyed Alireza Taghavi

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Several combination endoscopic therapies are currently in use. The present study aimed to compare argon plasma coagulation (APC + adrenaline injection (AI with hemoclips + AI for the treatment of high-risk bleeding peptic ulcers.

  7. Video: argon plasma coagulator in a 2-month-old child with tracheoesophageal fistula.

    Science.gov (United States)

    Nardo, Giovanni Di; Oliva, Salvatore; Barbato, Maria; Aloi, Marina; Midulla, Fabio; Roggini, Mario; Valitutti, Francesco; Frediani, Simone; Cucchiara, Salvatore

    2012-09-01

    A 2 month-old boy was admitted to the authors' hospital because of regurgitation and persistent cough during breastfeeding. A chest X-ray examination and a barium esophagogram disclosed small amounts of barium passing in the trachea, suggesting a tracheoesophageal fistula (TEF). Bronchoscopy combined with upper gastrointestinal (GI) endoscopy performed with the patient under general anesthesia confirmed the fistula. The TEF was treated by injection of 1 ml Glubran 2 from the esophageal side. A nasogastric tube was placed for feedings, and 7 days later, a barium esophagogram showed a reduction of caliber but not complete closure of the TEF. Unsuccessful fistula obliteration with Glubran was attributed to technical difficulties in catheterization of the fistula orifice, mainly resulting from its close proximity to the upper esophageal sphincter and to its small caliber. Therefore, an argon plasma coagulator (APC) probe with a circumferentially oriented nozzle was used from the esophageal side as an alternative technique to fulgurate the residual fistula orifice (see video). A nasogastric tube was placed for feedings. Oral feeding was started 7 days later when a barium esophagogram confirmed complete fistula closure. At the 2-year follow-up visit, the boy was asymptomatic, and the barium esophagogram was negative. This report describes a case in which esophagoscopy gave a clear view of the fistula due to its direction from esophagus to trachea. Complete fistula obliteration was not obtained with Glubran. However, APC was successfully used to close the residual fistula orifice. The authors suggest that APC can be used as an alternative endoscopic technique to repair TEF when other techniques fail.

  8. Long-term follow-up after complete ablation of Barrett's esophagus with argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    Ahmed Madisch; Stephan Miehlke; Ekkehard Bayerd(o)rffer; Birgit Wiedemann; David Antos; Anke Sievert; Michael Vieth; Manfred Stolte; Heinrich Schulz

    2005-01-01

    AIM: To report the long-term outcome of patients after complete ablation of non-neoplastic Barrett's esophagus (BE) with respect to BE relapse and development of intraepithelial neoplasia or esophageal adenocarcinoma.METHODS: In 70 patients with histologically proven nonneoplastic BE, complete BE ablation was achieved by argon plasma coagulation (APC) and high-dose proton pump inhibitor therapy (120 mg omeprazole daily). Sixty-six patients (94.4%) underwent further surveillance endoscopy. At each surveillance endoscopy four-quadrant biopsies were taken from the neo-squamous epithelium at 2 cm intervals depending on the pre-treatment length of BE mucosa beginning at the neo-Z-line, and from any endoscopically suspicious lesion.RESULTS: The median follow-up of 66 patients was 51 mo (range 9-85 mo) giving a total of 280.5 patient years.A mean of 6 biopsies were taken during surveillance endoscopies. In 13 patients (19.7%) tongues or islands suspicious for BE were found during endoscopy. In 8 of these patients (12.1%) non-neoplastic BE relapse was confirmed histologically giving a histological relapse rate of 3% per year. In none of the patients, intraepithelial neoplasia nor an esophageal adenocarcinoma was detected.Logistic regression analysis identified endoscopic detection of islands or tongues as the only positive predictor of BE relapse (P = 0.0004).CONCLUSION: The long-term relapse rate of nonneoplastic BE following complete ablation with high-power APC is low (3% per year).

  9. Efficacy of argon plasma coagulation in the management of portal hypertensive gastropathy

    Science.gov (United States)

    Hanafy, Amr Shaaban; El Hawary, Amr Talaat

    2016-01-01

    Objectives: Evaluation of the outcome and experience in 2 years of management of portal hypertensive gastropathy (PHG) by argon plasma coagulation (APC) in a cohort of Egyptian cirrhotic patients. Methods: This study was conducted over a 2-year period from January 2011 to February 2013. Upper gastrointestinal endoscopy was performed to evaluate the degree and site of PHG. APC was applied to areas with mucosal vascular lesions. Results: In total, 200 cirrhotic patients were enrolled; 12 patients were excluded due to death (n = 6) caused by hepatic encephalopathy (n = 3), hepatorenal syndrome (n = 2), or chronic lymphatic leukemia (n = 1), or did not complete the treatment sessions (n = 6), so 188 patients completed the study. PHG was mainly fundic in 73 patients (38.8 %), corporeal in 66 patients (35.1 %), and pangastric in 49 patients (26.1 %) (P = 0.026). Patients were exposed to APC and received proton pump inhibitors together with propranolol at a dose sufficient to reduce the heart rate by 25 % or down to 55 beats/min. The mean (± standard deviation) number of sessions was 1.65 ± 0.8; six patients needed four sessions (3.2 %), 19 patients needed three sessions (10.1 %), 74 patients needed two sessions (39.4 %), and 89 patients needed one session (47.3 %). Patients with fundic and corporeal PHG required the lowest number of sessions (P = 0.000). Patients were followed up every 2 months for up to 1 year; the end point was a complete response with improved anemia and blood transfusion requirement which was achieved after one session in 89 patients (75.4 %), two sessions in 24 patients (20.3 %) and three sessions in five patients (4.3 %). A complete response was more prevalent in patients with corporeal and fundic PHG (P = 0.04). Conclusions: After 2 years’ experience in managing PHG, we found that a combination of APC and non-selective beta blockers was highly efficacious and safe in controlling

  10. An Inflammatory Fibroid Polyp in the Hepatic Flexure of the Colon Treated with Argon Plasma Coagulation, Endoscopic Clipping and Polypectomy

    Directory of Open Access Journals (Sweden)

    Ariyo Ihimoyan

    2012-01-01

    Full Text Available Inflammatory fibroid polyp (IFP is a rare benign polypoid lesion of the gastrointestinal tract. Most IFPs occur in the stomach and colonic occurrence is very rare. Histologically IFP is characterized by a mixture of numerous small vessels, fibroblasts and edematous connective tissue associated with marked inflammatory infiltration by eosinophils. We present a rare case of a pedunculated IFP in the hepatic flexure of the colon treated successfully with a combination of argon plasma coagulation, endoclipping and polypectomy. A 74-year-old asymptomatic female underwent a screening colonoscopy in our hospital. A 12-mm pedunculated polyp was found at the hepatic flexure of the colon. After saline injection, we attempted to remove the polyp with a hot snare. However the polyp stalk was extremely difficult to resect despite several attempts with the hot snare. We placed an endoclip at the base of the stalk and then applied argon plasma coagulation at 1.0 l/min and 40 W. After these measures we were able to resect the stalk and the polyp was retrieved. Histologically the polyp was located in the submucosa of the gastrointestinal tract. Proliferation of spindle cells and infiltration of inflammatory cells such as plasma cells and eosinophils were observed. The spindle cells were positive for CD34 and S100 but negative for c-kit and muscle markers. These findings are consistent with a histopathological diagnosis of IFP.

  11. From electrocautery, balloon dilatation, neodymium-doped:yttrium-aluminum-garnet (Nd:YAG) laser to argon plasma coagulation and cryotherapy

    Science.gov (United States)

    Pickering, Edward M.; Lee, Hans J.

    2015-01-01

    Over the past decade, there has been significant advancement in the development/application of therapeutics in thoracic diseases. Ablation methods using heat or cold energy in the airway is safe and effective for treating complex airway disorders including malignant and non-malignant central airway obstruction (CAO) without limiting the impact of future definitive therapy. Timely and efficient use of endobronchial ablative therapies combined with mechanical debridement or stent placement results in immediate relief of dyspnea for CAO. Therapeutic modalities reviewed in this article including electrocautery, balloon dilation (BD), neodymium-doped:yttrium-aluminum-garnet (Nd:YAG) laser, argon plasma coagulation (APC), and cryotherapy are often combined to achieve the desired results. This review aims to provide a clinically oriented review of these technologies in the modern era of interventional pulmonology (IP). PMID:26807284

  12. Argon Plasma Coagulation Therapy Versus Topical Formalin for Intractable Rectal Bleeding and Anorectal Dysfunction After Radiation Therapy for Prostate Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yeoh, Eric, E-mail: eric.yeoh@health.sa.gov.au [Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide (Australia); School of Medicine, University of Adelaide, Adelaide (Australia); Tam, William; Schoeman, Mark [School of Medicine, University of Adelaide, Adelaide (Australia); Department of Gastroenterology, Royal Adelaide Hospital, Adelaide (Australia); Moore, James; Thomas, Michelle [School of Medicine, University of Adelaide, Adelaide (Australia); Department of Colorectal Surgery, Royal Adelaide Hospital, Adelaide (Australia); Botten, Rochelle; Di Matteo, Addolorata [Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide (Australia)

    2013-12-01

    Purpose: To evaluate and compare the effect of argon plasma coagulation (APC) and topical formalin for intractable rectal bleeding and anorectal dysfunction associated with chronic radiation proctitis. Methods and Materials: Thirty men (median age, 72 years; range, 49-87 years) with intractable rectal bleeding (defined as ≥1× per week and/or requiring blood transfusions) after radiation therapy for prostate carcinoma were randomized to treatment with APC (n=17) or topical formalin (n=13). Each patient underwent evaluations of (1) anorectal symptoms (validated questionnaires, including modified Late Effects in Normal Tissues–Subjective, Objective, Management, and Analytic and visual analogue scales for rectal bleeding); (2) anorectal motor and sensory function (manometry and graded rectal balloon distension); and (3) anal sphincteric morphology (endoanal ultrasound) before and after the treatment endpoint (defined as reduction in rectal bleeding to 1× per month or better, reduction in visual analogue scales to ≤25 mm, and no longer needing blood transfusions). Results: The treatment endpoint was achieved in 94% of the APC group and 100% of the topical formalin group after a median (range) of 2 (1-5) sessions of either treatment. After a follow-up duration of 111 (29-170) months, only 1 patient in each group needed further treatment. Reductions in rectal compliance and volumes of sensory perception occurred after APC, but no effect on anorectal symptoms other than rectal bleeding was observed. There were no differences between APC and topical formalin for anorectal symptoms and function, nor for anal sphincteric morphology. Conclusions: Argon plasma coagulation and topical formalin had comparable efficacy in the durable control of rectal bleeding associated with chronic radiation proctitis but had no beneficial effect on anorectal dysfunction.

  13. The role of argon plasma coagulation in the management of Barrett's esophagus: a single-center experience

    Directory of Open Access Journals (Sweden)

    Gad YZ

    2011-04-01

    Full Text Available Yahia Z Gad1, Adel A Zeid21Associate Professor of Internal Medicine, Mansoura Specialized Medical Hospital, Mansoura University, Mansoura, Egypt; 2Consultant Surgeon, Al Nil Hospital, Mansaura, EgyptBackground/aim: Patients with Barrett's esophagus (BE are 30 times more likely to develop esophageal adenocarcinoma (EAC than the general population. Data regarding the use of argon plasma coagulation (APC for treatment of patients with BE in Egypt are still limited. This article discusses the efficacy and safety of APC as a thermoablative modality in Egyptian patients with BE.Materials and methods: A total of 73 referred eligible patients with a confirmed endoscopic and histopathologic diagnosis of BE were enrolled in this study and subjected to thermoablation by high-power (hp-APC equipment at a 60 W setting until complete ablation or a maximum of five sessions and were followed up clinically and endoscopically at 3-month intervals. Computer-generated randomization allocated patients into APC-treated and control groups (n = 75, all of whom were treated with a proton pump inhibitor.Results: Minor and major complications occurred in 8 of 73 (10.95% and 1 of 73 (1.36% patients, respectively. Macroscopic ablation was achieved after one session in 37 of 73 (50.63% patients, and complete histologic ablation was confirmed after 167 sessions in 69 of 73 (94.52% patients. At 1-year follow-up, no relapses of BE or progression to EAC were observed.Conclusion: hp-APC at a medium-energy setting of 60 W in an acid-reduced environment can ablate BE effectively and safely with promising initial results.Keywords: Barrett's esophagus, argon plasma coagulation

  14. Endoscopic ablation of Barrett's esophagus using the second generation argon plasma coagulation: a prospective randomized controlled trail

    Institute of Scientific and Technical Information of China (English)

    Li Zhang; Lei Dong; Jia Liu; Xiaolan Lu; Jun Zhang

    2009-01-01

    Objective:To investigate the efficacy and safety of the second generation argon plasma coagulation(VIO APC) in the ablation of Barrett's Esophagus. Methods:A total of 35 patients with uncomplicated Barrett's esophagus entered into a prospective, randomized, unblinded study comparing the treatment VIO APC combined with a proton pump inhibiter with a proton pump inhibiter administered alone. VIO APC was performed at a power setting of 40W, and argon gas flow at 1.5-2.0 L/min, and "forced" mode. Ablative treatment was repeated until either no Barrett's epithelium remained or a maximum of 5 treatment sessions occurred. Results:In the ablation group, macroscopic complete ablation was achieved in 14 of 18 patients, and complete ablation confirmed by histology in 12 of 18 patients (P<0.01). Buried glands were observed in 2 patients who had achieved macroscopic ablation. The Barrett's mucosa averaged a reduction of 65%(range 50-75%) in the remaining 4 patients. In the control group, only 2 patients had partial regression, median 30%(range 20-40%).In the ablation group, post-treatment 4 patients had transient retrosternal pain, and 3 patients had mild epigastric discomfort. One patient had a small hemorrhage during the procedure, which ceased after norepinephrine and thrombosin were administered through the endoscope biopsy channel. No adverse events were observed in the control group. During 11.8(4-15) months follow-up, patients who had achieved the complete ablation have no evidence of relapse of Barrett's esophagus. Conclusion:VIO APC with a relatively low power setting can effectively ablate the Barrett's mucosa. No severe adverse events were observed. Long-term follow-up is needed to assess cancer prevention and the durability of the neo-squamous epithelium.

  15. Safety and efficacy of argon plasma coagulator ablation therapy for flat colorectal adenomas Seguridad y eficacia de la ablación de pólipos colorrectales con argón plasma

    OpenAIRE

    García, A.; O. Núñez; C. González-Asanza; Parera, A; L. Menchén; Ripoll, C.; Senent, C; E. Cos; P. Menchén

    2004-01-01

    Introduction: argon-plasma coagulation (APC) has been used safely and efficaciously in multiple settings including colon polyp treatment. The aim of this study was to evaluate APC efficacy and safety in the treatment of flat colorectal adenomas. Materials and methods: APC ablation was prospectively performed and evaluated in 22 consecutive patients with colorectal adenomas, 11 of which had large sessile adenomas that were treated with piecemeal polypectomy and APC ablation of residual adenoma...

  16. Comparison of Hemostatic Efficacy of Argon Plasma Coagulation with and without Distilled Water Injection in Treating High-Risk Bleeding Ulcers

    Directory of Open Access Journals (Sweden)

    Yuan-Rung Li

    2014-01-01

    Full Text Available Background. Argon plasma coagulation (APC is useful to treat upper gastrointestinal bleeding, but its hemostatic efficacy has received little attention. Aims. This investigation attempted to determine whether additional endoscopic injection before APC could improve hemostatic efficacy in treating high-risk bleeding ulcers. Methods. From January 2007 to April 2011, adult patients with high-risk bleeding ulcers were included. This investigation compared APC plus distilled water injection (combined group to APC alone for treating high-risk bleeding ulcers. Outcomes were assessed based on initial hemostasis, surgery, blood transfusion, hospital stay, rebleeding, and mortality at 30 days posttreatment. Results. Totally 120 selected patients were analyzed. Initial hemostasis was accomplished in 59 patients treated with combined therapy and 57 patients treated with APC alone. No significant differences were noted between these groups in recurred bleeding, emergency surgery, 30-day mortality, hospital stay, or transfusion requirements. Comparing the combined end point of mortality plus the failure of initial hemostasis, rebleeding, and the need for surgery revealed an advantage for the combined group (P=0.040. Conclusions. Endoscopic therapy with APC plus distilled water injection was no more effective than APC alone in treating high-risk bleeding ulcers, whereas combined therapy was potentially superior for patients with poor overall outcomes.

  17. Watermelon stomach: clinical aspects and treatment with argon plasma coagulation Ectasia vascular do antro gástrico ("watermelon stomach": aspectos clínicos e tratamento com coagulação com plasma de argônio

    Directory of Open Access Journals (Sweden)

    Dalton M. Chaves

    2006-09-01

    Full Text Available BACKGROUND: Gastric antral vascular ectasia is a disorder whose pathogenetic mechanism is unknown. The endoscopic treatment with argon plasma coagulation has been considered one of the best endoscopic therapeutic options. AIM: To analyze the endoscopic and clinical features of gastric antral vascular ectasia and its response to the argon plasma coagulation treatment. PATIENTS AND METHODS: Eighteen patients were studied and classified into two groups: group 1 - whose endoscopic aspect was striped (watermelon or of the diffuse confluent type; group 2 - diffuse spotty nonconfluent endoscopic aspect. RESULTS: Group 1 with eight patients, all having autoimmune antibodies, but one, whose antibodies were not searched for. Three were cirrhotic and three had hypothyroidism. All had gastric mucosa atrophy. In group 2, with 10 patients, all had non-immune liver disease, with platelet levels below 90.000. Ten patients were submitted to argon plasma coagulation treatment, with 2 to 36 months of follow-up. Lesions recurred in all patients who remained in the follow-up program and one did not respond to treatment for acute bleeding control. CONCLUSION: There seem to be two distinct groups of patients with gastric antral vascular ectasia: one related to immunologic disorders and other to non-immune chronic liver disease and low platelets. The endoscopic treatment using argon plasma coagulation had a high recurrence in the long-term evaluation.RACIONAL: "Watermelon stomach" ou ectasia vascular do antro gástrico é uma doença de etiopatogenia desconhecida. O tratamento endoscópico através da coagulação com plasma de argônio é considerado uma das melhores opções terapêuticas. OBJETIVO: Analisar os aspectos clínicos e endoscópicos da ectasia vascular do antro gástrico e a resposta ao tratamento com coagulação com plasma de argônio. PACIENTES E MÉTODOS: Dezoito pacientes foram estudados e classificados em dois grupos: grupo I - oito pacientes que

  18. Is argon plasma coagulation an effective and safe treatment option for patients with chronic radiation proctitis after high doses of radiotherapy?

    Directory of Open Access Journals (Sweden)

    Eduardo Hortelano

    grade 2 rectal incontinence, respectively. Conclusions: The argon plasma coagulation is an effective and safe management option in patients with medically refractory rectal bleeding after high doses of radiation for prostate cancer.

  19. 内镜下HFEC术对比APC术治疗大肠息肉的疗效探究%Clinical efficacy of endoscopic high frequency electric coagulation and argon plasma coagulation for colorectal polyps

    Institute of Scientific and Technical Information of China (English)

    刘伟

    2015-01-01

    目的 探究内镜下高频电凝切除术(High frequency electric coagulation,HFEC)与氩离子凝固术(Argon plasma coagulation,APC)在大肠息肉(Colorectal polyps,CP)治疗中的价值,为临床上CP治疗方式的选择提供依据.方法选择2009年3月-2014年3月在杭州师范大学附属医院接受治疗的CP患者980例,随机分成HFEC组490例(息肉653枚)和APC组490例(息肉688枚),HFEC组患者采用HFEC切除治疗,APC组则采用APC术治疗.治疗后,统计2组患者一次清除率和并发症发生率,据此评价两种术式对CP治疗的价值.结果采用SPSS19.0进行统计学分析,行x2检验,以P<0.05为差异具有统计学意义.结果 APC组一次切除息肉635枚,两次及以上切除53枚,一次切除率为92.3%,而HFEC组一次切除息肉562枚,两次及以上切除91枚,一次切除率为86.1%,2组一次切除率比较,差异具有统计学意义(x2 =13.58,P<0.05);APC组发生腹胀22例,腹痛13例,穿孔1例,出血2例,并发症率为7.8%;HFEC组发生腹胀34例,腹痛21例,穿孔6例,出血9例,并发症率为14.3%,2组并发症率比较,差异具有统计学意义(x2=10.66,P<0.05).结论 APC术治疗CP一次切除率高,且并发症低,安全可靠,是CP患者较佳的治疗方式.

  20. Microwave Argon Plasma Torch

    Science.gov (United States)

    2013-07-01

    an electron-ion pair in the discharge. Fig. 2. EEDF is non - Maxwellian and changes along the plasma column The electron–neutral collision...plasma radius. Even at atmospheric pressure the EEDF is non - Maxwellian and it is changing along the plasma column. ...18 31st ICPIG, July 14-19, 2013, Granada, Spain EEDF usually strongly differs from Maxwellian and chages along the plasma column (this is

  1. Safety and efficacy of argon plasma coagulator ablation therapy for flat colorectal adenomas Seguridad y eficacia de la ablación de pólipos colorrectales con argón plasma

    Directory of Open Access Journals (Sweden)

    A. García

    2004-05-01

    Full Text Available Introduction: argon-plasma coagulation (APC has been used safely and efficaciously in multiple settings including colon polyp treatment. The aim of this study was to evaluate APC efficacy and safety in the treatment of flat colorectal adenomas. Materials and methods: APC ablation was prospectively performed and evaluated in 22 consecutive patients with colorectal adenomas, 11 of which had large sessile adenomas that were treated with piecemeal polypectomy and APC ablation of residual adenomatous tissue, whereas the remaining eleven patients with flat or carpet-like adenomas were only treated with APC. The mean initial longitudinal extension of adenomas to be treated with APC was 22 mm (range, 20 to 40 mm. Results: the mean age of patients was 70 years. Adenomas were found most frequently in the rectum (50% and cecum (23%. Complete ablation was achieved in 90.9% of adenomas. Recurrence was observed in 20% of patients, all of them in the rectum, after a mean follow-up period of 16.3 months (range, 8 to 35. All recurrences were managed satisfactorily. No major complications were seen. Conclusions: argon plasma coagulator ablation of flat colorectal adenomas is an efficacious and safe technique, specially in the right colon, but results must be confirmed in controlled trials with a higher number of patients.Introducción: el argón plasma (AP, como terapia endoscópica, ha sido utilizado en diferentes lesiones digestivas, incluyendo la ablación de tejido adenomatoso de pólipos colorrectales. El objetivo del presente estudio fue evaluar la seguridad y efectividad del tratamiento con AP de pólipos colorrectales. Material y métodos: se valoró de forma prospectiva la aplicación en la práctica clínica de AP en el tratamiento de 22 pacientes con pólipos colorrectales, de los cuales 11 pacientes con pólipos de gran tamaño fueron tratados con polipectomía endoscópica fragmentada más ablación del tejido adenomatoso con AP, y los otros 11

  2. Electrical and spectroscopic characterization of a surgical argon plasma discharge

    Science.gov (United States)

    Keller, Sandra; Bibinov, Nikita; Neugebauer, Alexander; Awakowicz, Peter

    2013-01-01

    For electrosurgical procedures, the argon plasma coagulation (APC) discharge is a well-established atmospheric-pressure plasma tool for thermal haemostasis and devitalization of biological tissue. To characterize this plasma source, voltage-current measurements, microphotography, optical emission spectroscopy and numerical simulation are applied. Two discharge modes are established during the operation of the APC plasma source. A short transient spark discharge is ignited within the positive half period of the applied high voltage after a streamer channel connects the APC probe and the counter-electrode. During the second phase, which continues under negative high voltage, a glow discharge is stabilized in the plasma channel.

  3. 内镜下氩离子凝固术治疗老年人大肠息肉%Endoscopic argon plasma coagulation in the treatment of elderly patients with colorectal polyps

    Institute of Scientific and Technical Information of China (English)

    邵耘; 何晓璞; 吴爱娟; 陈国胜; 许海尘; 薛绮萍; 孙为豪

    2012-01-01

    目的 探讨内镜下氩离子凝固术(APC)治疗老年人大肠息肉的安全性和有效性.方法 采用德国ERBE 公司生产的APC(VI0 200D型)内镜专用氩气刀对电子肠镜检查发现的大肠息肉进行内镜下治疗.结果 258例老年患者共检出525枚息肉全部使用APC治愈,根据息肉大小和形态,使用APC灼除302枚(57.5%),APC切除89枚(17%),黏膜下注射后APC切除134枚(25.5%),局部渗血者行APC电凝或钛夹止血.术后2例(0.8%)出现少量便血,予药物治疗后出血停止,无穿孔和大出血等严重并发症.结论 APC可作为老年人大肠息肉的首选治疗,安全性高,并发症少.%Objective To evaluate the safety and efficacy of endoscopic argon plasma coagulation (APC) in the treatment of elderly patients with colorectal polyps. Methods Colorectal polyps found in electronic enteroscopy were treated with argon plasma generated by ERBE APC (VIO 200D, ERBE Company, German) . Results A total of 525 polyps were detected in 258 elderly patients and all were cured by APC. According to the polyp size and morphology, 302 (57.5%) sessile flat polyps with diameter 0.2 cm to 0.5 cm were ablated with APC, 89 (17%) semi-pedunculated and pedunculated polyps were resected by high-frequency electrosection, and 134 sessile (25.5%) polyps with diameter 0.6 cm to 5.0 cm were resected after submucosal injection with epinephrine plus methylene blue normal saline on focal membrane. APC electric coagulation or titanium clip was employed when bleeding appeared in partial wounds. Minor bleeding occurred in two patients (0.8%) and was stopped after treated with hemostatic drugs; there were no serious complications such as perforations or bleeding requiring transfusion. Conclusion APC is a well tolerated and effective treatment for elderly patients with colorectal polyps.

  4. Combination of Argon Plasma Coagulation and Cryotherapy in Treatment of Central Type Lung Cancer%APC联合冷冻治疗53例中央型肺癌

    Institute of Scientific and Technical Information of China (English)

    王江红; 王珏; 易楠; 项颖

    2009-01-01

    目的 探讨经支气管镜氩等离子体凝固(argon plasma coagulation,APC)结合冷冻治疗中央型肺癌的疗效及安全性.方法 经支气管镜对53例中央型肺癌患者进行APC结合冷冻治疗,其中非小细胞肺癌(NSCLC)46例,小细胞肺癌(SCLC)7例,从症状改善情况、肺功能、血气分析、气促评分、体力状况变化、狭窄再通疗效等方面进行评价.结果 53例病人经136次治疗后完全有效29例(54.7%)、部分有效21例(39.6%)、轻度有效2例(3.8%)、无效1例(1.9%).仅有少数病例出现一过性轻、中度低氧血症(19.9%).结论 经支气管镜应用APC结合冷冻治疗中央型肺癌安全、有效.

  5. 氩离子凝固术治疗结直肠息肉的临床应用价值%Application value of curing colorectal polyps with the argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    张兰霞; 张鸣青; 王爱民

    2012-01-01

    Objective To evaluate the efficacy and the clinical value of argon plasma coagulation ( APC) in the treatment of colorectal polyps. Methods One hundred and sixty patients with 351 colorectal polyps were treated with APC ablation. 214 sessile and 65 semi-pedunculated polyps were only treated with APC, 72 pedunculated polyps were treated with polypectomy and polyp remnants were also treated with APC. Results All of the patients were healed. Symptomless emphysema under the local mucosal occurred in 2 patients. Transient mild abdominal pain occurred in 78 patients and relieved without treatment. Conclusion APC is an effective and safe method for treating colorectal polyp. It is easy to operate with fewer complications and can be the preferred method for the applanate and wide outsole polyps.%目的 探讨氩离子凝固术治疗结直肠息肉的疗效及临床应用价值.方法 对160例患者共351枚结直肠息肉行氩离子凝固术(APC)治疗,其中214枚扁平和65枚亚蒂息肉仅行APC治疗,72枚有蒂息肉电切治疗后用APC处理息肉残端.结果 本组病例全部临床治愈.2例患者出现无症状的局部黏膜下气肿,78例患者出现短暂腹痛,未行处理自行缓解.结论 APC是一种安全有效的结直肠息肉治疗方法,副反应少,操作简便,尤其是在扁平、广基息肉的治疗中可作为首选方法.

  6. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  7. Efficacy and safety of argon plasma coagulation for the treatment of hemorrhagic radiation proctitis Eficacia y seguridad de la electrocoagulación con plasma de argón en el tratamiento del sangrado rectal secundario a proctitis por radioterapia

    Directory of Open Access Journals (Sweden)

    C. de la Serna Higuera

    2004-11-01

    Full Text Available Objective: to evaluate the efficacy, safety and medium-/long-term clinical course of patients undergoing endoscopic treatment with argon plasma coagulation for hemorrhagic radiation proctopathy. Design: descriptive, retrospective study with medium- and long-term follow-up. Patients, material and methods: ten patients were treated with argon plasma coagulation for hemorrhagic radiation proctopathy between July 1998 and February 2003. Inclusion criteria were: evidence of chronic rectal bleeding, consistent endoscopic findings, and absence of any other cause of hematochezia after a comprehensive ano-rectal examination and complete colonoscopy. The equipment used was a standard colonoscope, an argon delivery unit, an argon plasma coagulation probe 1.5 mm in internal diameter, and a high-frequency electrosurgical generator. Consecutive treatment sessions were programmed whenever it was considered necessary until all mucosal lesions had been treated. Clinical and evolutive follow-up was performed with a focus on tolerance, efficacy, and potential argon plasma coagulation-related complications. Data were updated by personal or telephonic interview. Results: in all patients, chronic rectal bleeding stopped after the last treatment session. The mean number of treatment sessions to stop symptoms was 1.7. Mean follow-up was 31.1 months. All sessions were well tolerated, similarly to standard rectoscopy. In one case a recurrence of rectal bleeding was observed four months later, which required two repeat sessions. Four patients were anemic at inclusion. Three of them reported a resolved anemia at the end of the study. No delayed argon plasma coagulation-related complications such us ulcers or strictures were seen. Conclusions: argon plasma coagulation appears to be a useful, effective and safe treatment for rectal bleeding resulting from chronic radiation proctitis when compared to standard medical and endoscopic treatments. These successful outcomes seem

  8. Clinical analysis of effect of endoscopic cryotherapy and argon plasma coagulation on 28 cases of Bronchial Tuberculosis%经支气管镜冷冻联合氩气刀治疗支气管结核28例临床分析

    Institute of Scientific and Technical Information of China (English)

    苗玉昴; 齐曼古力·吾守尔; 胡昕; 夏宇; 王晶

    2012-01-01

    Objective To approach the effectiveness of effect of endoscopic cryotherapy and argon plasma coagulation on airway constriction in 28 cases of Bronchial Tuberculosis. Methods 28 cases of airway constriction with Bronchial Tuberculosis received endo scopic cryotherapy and argon plasma coagulation, and clinical symptoms, iconography and endoscopic changes were compared before and alter treatment. Results Every patient underwent 4. 7 times cryotherapy and argon plasma coagulation in the mean course of 1 . 6 months. Rate of complete response, partial response, mild response and invalidity were respectively 57. 1% ( 16/28 ), 35.7% ( 10/28 ), 7.1% ( 2/28 ) and 0. Only two of them was Pneumothorax and the rest of them had no adverse reaction. After 1 ~ 4 months of follow - up , re -stenosis occurred in 4 cases and received stent implantation. Long - term efficiency was 71 A% ( 20/28 ). Conclusions Endoscopic cry otherapy and argon plasma coagulation on airway constriction in treatment of Bronchial Tuberculosis are simple, effective and sale.%目的 探讨经支气管镜介入冷冻联合氩气刀治疗结核性大气道狭窄的疗效.方法 对28例支气管结核患者的狭窄气道进行冷冻联合氩气刀治疗,比较治疗前后的临床表现、影像学及镜下改变等指标来进行疗效评价.结果 28例患者经过平均1.6个月和平均4.7次/人的治疗,完全有效57.1%(16/28),部分有效35.7%(10/28),轻度有效7.1%(2/28),无效0例.术中有2例出现气胸,其余的未见明显不良反应,经过1~4月的随访,4例出现再次狭窄而采取支架植入治疗,长期有效率达71.4%(20/28).结论 冷冻联合氩气刀治疗支气管结核是一项安全、有效、简便的支气管治疗方法.

  9. Efficacy of Argon Plasma Coagulation in Management of Different Pathologic Types Colorectal Polyps%氩离子凝固术治疗不同病理类型结直肠息肉的疗效观察

    Institute of Scientific and Technical Information of China (English)

    赵曙光; 王旭霞; 黄裕新; 闻勤生; 赵保民

    2008-01-01

    目的:氩离子凝固术(Argon-plasma coagulation,APC)可以有效地治疗结直肠息肉,对不同病理类型息肉的疗效是否存在差异,目前尚不清楚.本文比较APC治疗不同病理类型结直肠息肉的效果.方法:对62例结直肠息肉患者共112枚结肠息肉行APC治疗,其中17例亚蒂和74例扁平息肉仅用APC治疗;21例有蒂息肉电切治疗后用APC处理息肉残基,治疗结束后1个月进行结肠镜随访.结果:112枚结直肠息肉经一次APC治疗均成功清除,随访期间共有4例(6.5%)患者出现复发,均为直肠腺瘤性息肉,经再次APC治疗后彻底清除.单纯APC治疗组复发3枚(3.3%);电切后用APC处理残端组术后复发1枚(4.7%),两组间复发率无显著差别(P>0.05),腺瘤性息肉的复发率显著高于其他两种病理类型(P<0.05).1例直肠有蒂息肉经圈套器切除后APC处理残端时出现黏膜下气肿,3例患者出现了短暂的腹痛,未经处理缓解,其余患者无特殊并发症.结论:APC是一种安全有效的结直肠息肉治疗方法,但对腺瘤性息肉APC治疗后应加强随访,以确保治疗成功.

  10. Merging of high speed argon plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Case, A.; Messer, S.; Brockington, S.; Wu, L.; Witherspoon, F. D. [HyperV Technologies Corp., Chantilly, Virginia 22180 (United States); Elton, R. [University of Maryland, College Park, Maryland 20742 (United States)

    2013-01-15

    Formation of an imploding plasma liner for the plasma liner experiment (PLX) requires individual plasma jets to merge into a quasi-spherical shell of plasma converging on the origin. Understanding dynamics of the merging process requires knowledge of the plasma phenomena involved. We present results from the study of the merging of three plasma jets in three dimensional geometry. The experiments were performed using HyperV Technologies Corp. 1 cm Minirailguns with a preionized argon plasma armature. The vacuum chamber partially reproduces the port geometry of the PLX chamber. Diagnostics include fast imaging, spectroscopy, interferometry, fast pressure probes, B-dot probes, and high speed spatially resolved photodiodes, permitting measurements of plasma density, temperature, velocity, stagnation pressure, magnetic field, and density gradients. These experimental results are compared with simulation results from the LSP 3D hybrid PIC code.

  11. Coagulation of dust particles in a plasma

    Science.gov (United States)

    Horanyi, M.; Goertz, C. K.

    1990-01-01

    The electrostatic charge of small dust grains in a plasma in which the temperature varies in time is discussed, pointing out that secondary electron emission might introduce charge separation. If the sign of the charge on small grains is opposite to that on big ones, enhanced coagulation can occur which will affect the size distribution of grains in a plasma. Two scenarios where this process might be relevant are considered: a hot plasma environment with temperature fluctuations and a cold plasma environment with transient heating events. The importance of the enhanced coagulation is uncertain, because the plasma parameters in grain-producing environments such as a molecular cloud or a protoplanetary disk are not known. It is possible, however, that this process is the most efficient mechanism for the growth of grains in the size range of 0.1-500 microns.

  12. Valoración de la respuesta endoscópica al tratamiento con argón plasma en la rectitis actínica crónica Evaluation of the endoscopic response to argon plasma coagulation in patients with chronic radiation proctopathy

    Directory of Open Access Journals (Sweden)

    M. Latorre Sánchez

    2008-10-01

    Full Text Available Objetivo: valorar la mejoría endoscópica tras el tratamiento con argón plasma utilizado para el control sintomático de las rectitis actínicas crónicas. Diseño y pacientes: estudio prospectivo de 48 meses de duración, con 38 pacientes (26 hombres y 12 mujeres, con edad media de 70,9 ± 7,38 años. Todos presentaban algún grado de rectorragia y/o anemia. Se realizaron entrevistas clínicas, analíticas y sesiones endoscópicas con argón, de forma periódica mensual, hasta la normalización analítica y cese del sangrado, con un seguimiento posterior de 24 meses. Para valorar la mejoría se utilizaron parámetros analíticos, gradación de sangrado (Chutckan y un índice endoscópico. Resultados: el tiempo medio trascurrido entre el inicio y la finalización del seguimiento fue de 28,5 ± 3,9 meses. La media de sesiones administradas por paciente ha sido de 3,6 ± 2,7. Si comparamos los síntomas antes, después del tratamiento existe una disminución significativa en el grado de rectorragia según la clasificación de Chutkan (2,29 ± 1,08 vs. 0,59 ± 1,12, p Objectives: to evaluate endoscopic improvement after argon plasma coagulation (APC in symptomatic patients with chronic radiation proctopathy. Methods and patients: a prospective study of 38 patients with radiation proctitis (26 males and 12 females, mean age 70.9 ± 7.38 yrs, and with rectal bleeding and or anemia. We performed monthly interviews, blood tests, and APC sessions until rectal bleeding had ceased and hemoglobin and ferritin levels were improved, with a follow-up of 24 months. We used blood testing, bleeding scores (Chutckhan's index, and endoscopic scores to evaluate improvement. Results: mean time between inclusion and follow-up completion was 28.5 ± 3.9 months. Mean number of sessions per patient was 3.6 ± 2.7. There was a significant decrease (2.29 ± 1.8 vs. 0.59 ± 1.12, p < 0.05 in rectal bleeding (Chutckan score from baseline after APC. There was a significant

  13. FORMATION OF CARBON NANOSTRUCTURES USING ACETYLENE, ARGON-ACETYLENE AND ARGON-HYDROGEN-ACETYLENE PLASMAS

    OpenAIRE

    Marcinauskas, Liutauras; Grigonis, Alfonsas; Valincius, Vitas

    2013-01-01

    The amorphous carbon films were deposited on silicon-metal substrates by plasma jet chemical vapor deposition (PJCVD) and plasma enchanted CVD (PECVD). PJCVD carbon films have been prepared at atmospheric pressure in argon-acetylene and argon-hydrogen-acetylene plasma mixtures. The films deposited in Ar-C2H2 plasma are attributed to graphite-like carbon films. The formation of the nanocrystalline graphite was obtained in Ar-H2-C2H2 plasma. Addition of the hydrogen gas lead to the ...

  14. Perioperative coagulation management--fresh frozen plasma.

    Science.gov (United States)

    Kor, Daryl J; Stubbs, James R; Gajic, Ognjen

    2010-03-01

    Clinical studies support the use of perioperative fresh frozen plasma (FFP) in patients who are actively bleeding with multiple coagulation factor deficiencies and for the prevention of dilutional coagulopathy in patients with major trauma and/or massive haemorrhage. In these settings, current FFP dosing recommendations may be inadequate. However, a substantial proportion of FFP is transfused in non-bleeding patients with mild elevations in coagulation screening tests. This practice is not supported by the literature, is unlikely to be of benefit and unnecessarily exposes patients to the risks of FFP. The role of FFP in reversing the effects of warfarin anticoagulation is dependent on the clinical context and availability of alternative agents. Although FFP is commonly transfused in patients with liver disease, this practice needs broad reconsideration. Adverse effects of FFP include febrile and allergic reactions, transfusion-associated circulatory overload and transfusion-related acute lung injury. The latter is the most serious complication, being less common with the preferential use of non-alloimmunised, male-donor predominant plasma. FP24 and thawed plasma are alternatives to FFP with similar indications for administration. Both provide an opportunity for increasing the safe plasma donor pool. Although prothrombin complex concentrates and factor VIIa may be used as alternatives to FFP in a variety of specific clinical contexts, additional study is needed.

  15. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 < t°a < 72 dyne/cm (O° ≤ theta < 120°), falling sharply through a broad minimum within the 20 < t°a < 40 dyne/cm (55° < theta < 75°). Furthermore, contact activation of FXII in buffer solution produces an ensemble of protein fragments exhibiting either procoagulant properties in plasma (proteolysis of blood factor XI or prekallikrein), amidolytic properties (cleavage of s-2302 chromogen), or the ability to suppress autoactivation through currently unknown biochemistry. The relative proportions of these fragments depend on activator surface chemistry/energy. We have also discovered that contact activation is moderated by adsorption of plasma proteins unrelated to coagulation through an

  16. Argon plasma coagulation and hyperbaric oxygen therapy in chronic radiation proctopathy, effectiveness and impact on tissue toxicity Argón plasma y oxígeno hiperbárico para el control de la rectorragia crónica secundaria a la proctopatía por radiación

    Directory of Open Access Journals (Sweden)

    Julio César Álvaro-Villegas

    2011-11-01

    Full Text Available Background: chronic radiation proctopathy (CRP is associated with recurrent rectal bleeding and transfusional requirements. Argon plasma coagulation (APC and hyperbaric oxygen therapy (HOT have been shown to be effective in the control of CRP. No prospective comparisons have been reported between these treatments. Aim: the aim was to evaluate the effectiveness, safety and impact on tissue toxicity of APC compared to HOT in patients with CRP. Material and methods: a prospective study for evaluating treatment response was conducted. Patients with cervical cancer and CRP with rectal bleeding were recruited. They had not received previous treatment. Collected data included: demographics, previous radiation dosage, duration and severity of rectal bleeding. Hemoglobin, transfusional requirements, and tissue toxicity (SOMA LENT questionnaire at baseline and at 1, 2, and 3 months follow up were recorded. Results: thirty-one patients were included, 14 in the APC group and 17 in the HOT group. No response was noted in 13 and 18% of patients in the APC and HOT group respectively (p = NS. At the 1 and 2 months follow-up, the APC group showed a significantly better response in terms of transfusional requirements (0.6 vs. 3.4 and 0.7 vs. 2.5 and tissue toxicity score (5.3 vs. 8.6 and 3.8 vs. 7.248. After 3 months, both groups showed further improvement in all parameters without significant differences between them. Conclusions: APC and HOT were effective, safe and decreased the tissue toxicity scores in patients with CRP. However, response rate was higher and faster in the APC group.Introducción: la proctopatía por radiación (PPR se asocia con rectorragía recurrente y requerimientos de trasfusiones. La coagulación con argón plasma (APC y la terapia con oxígeno hiperbárico (HOT han sido efectivas en el control de la PPR. No hay estudios prospectivos comparativos entre ambas técnicas. Objetivo: el objetivo del estudio es evaluar la efectividad

  17. Therapeutic effect of argon plasma coagulation and cryotherapy combined with radiotherapy on patients with central type lung cancer%经支气管镜氩等离子体凝固及冷冻结合体外放射联合治疗中央型肺癌疗效的临床研究

    Institute of Scientific and Technical Information of China (English)

    何小鹏; 刘小伟; 党焱; 王利; 杨友文; 朱波; 陈剑辉; 马玉娟

    2013-01-01

    [Objective] To study the efficacy and safety of argon plasma coagulation (APC) and cryotherapy through bronchoscope combined with radiation on patients with central type lung cancer.[Methods] 60 patients with central type lung cancer patients were divided into two groups.35 cases in treatment group,with combined therapy.The control group 25 cases,radiation treatment.Clinical symptom,life quality scroe,airway obstruction were measured before and after treatment.[Results] After average 4 times APC and cryotherapy through bronchoscope,result compared with control group,the remission rate of clinical symptoms,airway obstruction,and improve of life quality score were markedly highter,two group had a statistically difference (P <0.05).[Conclusion] Radiation combined with APC and cryotherapy through bronchoscope is a effective and safe therapy for the patients with central type lung cancer.%目的 探讨经支气管镜氩等离子体凝固(APC)及冷冻技术结合体外放射治疗中央型肺癌的疗效.方法 对35例确诊为中心型肺癌的患者进行联合治疗,并与单纯放疗患者进行对比,以观察其疗效.结果 经平均4次的介入治疗,治疗组临床症状、生活质量评分、气道阻塞的缓解相对于对照组均有明显改善,其差异具有显著性(P<0.05).结论 经支气管镜APC及冷冻技术结合体外放疗是治疗中心型肺癌的安全有效方法.

  18. Tin LPP plasma control in the argon cusp source

    Science.gov (United States)

    McGeoch, Malcolm W.

    2016-03-01

    The argon cusp plasma has been introduced [1,2] for 500W class tin LPP exhaust control in view of its high power handling, predicted low tin back-scatter from a beam dump, and avoidance of hydrogen usage. The physics of tin ion control by a plasma is first discussed. Experimentally, cusp stability and exhaust disc geometry have previously been proved at full scale [2], the equivalent of 300W-500W usable EUV. Here we verify operation of the plasma barrier that maintains a high argon density next to the collector, for its protection, and a low density in the long path toward the intermediate focus, for efficiency. A pressure differential of 2Pa has been demonstrated in initial work. Other aspects of tin LPP plasma control by the cusp have now been demonstrated using tin ions from a low Hz 130mJ CO2 laser pulse onto a solid tin surface at the cusp center. Plasma is rejected at the design to match a specified exhaust power is discussed. In view of this work, argon cusp exhaust control appears to be very promising for 500W class tin LPP sources.

  19. Bacteria Inactivation Using DBD Plasma Jet in Atmospheric Pressure Argon

    Institute of Scientific and Technical Information of China (English)

    XU Guimin; ZHANG Guanjun; SHI Xingmin; MA Yue; WANG Ning; LI Yuan

    2009-01-01

    A coaxial dielectric barrier discharge plasma jet Was designed,which can be operated in atmospheric pressure argon under an intermediate frequency sinusoidal resonant power supply,and an atmospheric pressure glow-like discharge Was achieved.Two kinds of typical bacteria,i.e.,the Staphylococcus aureus(S.aurens)and Escherichia coil(E.coil),were employed to study the bacterial inactivation mechanism by means of the non-thermal plasma.The killing log value (KLV)of S.aureus reached up to 5.38 with a treatment time of 90 s and that of E.coil up to 5.36 with 60 s,respectively.According to the argon emission spectra of the plasma jet and the scanning electron microscope (SEM) images of the two bacteria before and after the plasma treatment.it is concluded that the reactive species in the argon plasma played a major role in the bacterial inactivation,while the heat,electric field and UV photons had little effect.

  20. Investigation of Non-Equilibrium Argon and Hydrogen Plasmas.

    Science.gov (United States)

    Braun, Christopher Gifford

    1987-09-01

    Theoretical and experimental investigations are made into non-equilibrium argon and hydrogen partially -ionized plasmas characteristic of glow discharge devices such as thyratrons and discharge tubes. For an argon plasma, the development and use of a collisional-radiative, steady -state, three-energy-level model is presented and experimental measurements on pulsed argon plasmas are briefly mentioned. Two different theoretical argon plasma models are discussed; the first is numerically solved using a non-Maxwellian electron distribution function, while the second is solved analytically, including atom-atom inelastic collisions, assuming Maxwellian electron and atom distribution functions. For a hydrogen plasma, experimental measurements using fluorescence and laser-induced fluorescence have been made in a modified hydrogen thyratron over a wide current density range (from 100 to 8,000 A/cm('2)) for the atomic hydrogen population densities n = 2,3,4. A pronounced rise in the atomic hydrogen excited state populations is observed after the end of the current pulse. A new method to measure the time-resolved electron density has been developed and results are presented. A time-dependent model for atomic hydrogen plasmas typical of a thyratron has been constructed, and preliminary results are shown. This model includes ten atomic energy levels (n = 1 to n = 9 and the continuum), takes into account energy balance with an externally supplied current density and assumes a Maxwellian electron distribution function. Implications of these measurements and theoretical analysis upon the operation of thyratrons are discussed. (Copies available exclusively from Micrographics Department, Doheny Library, University of Southern California, Los Angeles, CA 90089 -0182.).

  1. Behavior of Excited Argon Atoms in Inductively Driven Plasmas

    CERN Document Server

    Hebner, G A

    1999-01-01

    Laser induced fluorescence has been used to measure the spatial distribution of the two lowest energy argon excited states, 1s sub 5 and 1s sub 4 , in inductively driven plasmas containing argon, chlorine and boron trichloride. The behavior of the two energy levels with plasma conditions was significantly different, probably because the 1s sub 5 level is metastable and the 1s sub 4 level is radiatively coupled to the ground state but is radiation trapped. The argon data is compared with a global model to identify the relative importance of processes such as electron collisional mixing and radiation trapping. The trends in the data suggest that both processes play a major role in determining the excited state density. At lower rfpower and pressure, excited state spatial distributions in pure argon were peaked in the center of the discharge, with an approximately Gaussian profile. However, for the highest rfpowers and pressures investigated, the spatial distributions tended to flatten in the center of the disch...

  2. Conclusive evidence of abrupt coagulation inside the void during cyclic nanoparticle formation in reactive plasma

    Science.gov (United States)

    van de Wetering, F. M. J. H.; Nijdam, S.; Beckers, J.

    2016-07-01

    In this letter, we present scanning electron microscopy (SEM) results that confirm in a direct way our earlier explanation of an abrupt coagulation event as the cause for the void hiccup. In a recent paper, we reported on the fast and interrupted expansion of voids in a reactive dusty argon-acetylene plasma. The voids appeared one after the other, each showing a peculiar, though reproducible, behavior of successive periods of fast expansion, abrupt contraction, and continued expansion. The abrupt contraction was termed "hiccup" and was related to collective coagulation of a new generation of nanoparticles growing in the void using relatively indirect methods: electron density measurements and optical emission spectroscopy. In this letter, we present conclusive evidence using SEM of particles collected at different moments in time spanning several growth cycles, which enables us to follow the nanoparticle formation process in great detail.

  3. Flush-mounted probe diagnostics for argon glow discharge plasma

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Liang, E-mail: xld02345@mail.ustc.edu.cn; Cao, Jinxiang; Liu, Yu; Wang, Jian; Du, Yinchang; Zheng, Zhe; Zhang, Xiao; Wang, Pi [Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhang, Jin; Li, Xiao; Qin, Yongqiang; Zhao, Liang [Science and Technology on Space Physics Laboratory, Beijing 100076 (China)

    2014-09-15

    A comparison is made between plasma parameters measured by a flush-mounted probe (FP) and a cylindrical probe (CP) in argon glow discharge plasma. Parameters compared include the space potential, the plasma density, and the effective electron temperature. It is found that the ion density determined by the FP agrees well with the electron density determined by the CP in the quasi-neutral plasma to better than 10%. Moreover, the space potential and effective electron temperature calculated from electron energy distribution function measured by the FP is consistent with that measured by the CP over the operated discharge current and pressure ranges. These results present the FP can be used as a reliable diagnostic tool in the stable laboratory plasma and also be anticipated to be applied in other complicated plasmas, such as tokamaks, the region of boundary-layer, and so on.

  4. 高频电刀氩气刀治疗伴呼吸功能不全的大气道肿瘤效果和安全性%Efficacy and safety of electrocautery and argon plasma coagulation for the therapy of central airway tumor with respiratory insufficiency

    Institute of Scientific and Technical Information of China (English)

    周一平; 陈小可; 刘慧; 夏莉萍; 喻海琼; 刘念; 李爱芬; 林海容

    2015-01-01

    目的:探讨经支气管镜高频电刀氩气刀治疗伴呼吸功能不全大气道肿瘤的有效性和安全性。方法分析广东医学院附属福田医院2010年9月~2014年12月19例经病理确诊的伴呼吸功能不全的晚期中央型肺癌患者的高频电刀氩气刀治疗情况。结果19例患者共进行了37次治疗,手术室全麻6人6次,其他31次均在支气管镜室非全麻下手术,25次辅助通气下进行。有效8例,部分有效7例,轻度有效3例。同时进行光动力照射治疗的有6例,置入金属支架的有1例。结论治疗大气道肿瘤伴呼吸功能不全,选择良好的麻醉和呼吸支持方式后,高频电刀氩气刀术是一种安全、有效的方法。%Objective To investigate the efficacy and safety of electrocautery and argon plasma coagulation (APC) for the therapy of central airway tumor with respiratory insufficiency. Methods The efficacy of electrocautery and APC for the therapy of 19 pathologically confirmed advanced central airway tumor with respiratory insufficiency from September 2010 to December 2014 in Affiliated Futian Hospital of Guangdong Medical College was analyzed. Results Of the 19 patients with a total of 37 treatments, 6 patients and 6 periods were in the operating room under general anesthesia;the other 31 periods were in the bronchoscopy room under potical anesthesia with sedation, 25 periods with assisted me-chanical ventilation. 8 cases were effective, 7 cases were partial response, 3 cases were mild effective. 6 cases took si-multaneous photodynamic therapy, one case took metal stent implantation. Conclusion With the proper anesthesia and respiratory support, electrocautery and APC is a safe and effective method for central airway tumor with respiratory in-sufficiency.

  5. 支气管镜介导下氩气刀与氩气刀联合冷冻技术治疗气道狭窄的对照研究%Prospective study of argon plasma coagulation(APC)and cryotherapy combined with APC under bronchoscopy for airway stenosis

    Institute of Scientific and Technical Information of China (English)

    程剑剑; 陈献亮; 张文平; 齐咏; 刘红梅; 马芸

    2011-01-01

    Objective To compare the efficacy and safety of argon plasma coagulation(APC)with cryotherapy combined with APC under flexible bronchoscopy to treat airway stenosis.Methods Patients with inoperable airway stenosis which are suitable for APC treatment are assigned to APC group or APC combined with cryotherapy group randomly.Then,evaluate the effect of the two different therapy by bronchoscopy.Results Fourteen of the total 40 patients have to undergo other therapy such as implanting stents and/or brachytherapy because of their special conditions,6 of them belonging to APC group,8 of them belonging to APC combined with cryotherapy group.Forty patients underwent 127 times of bronchoscopy.No differences in efficacy and safety were discovered between the two groups(P=0.173).Conclusions APC and cryotherapy combined with APC under bronchoscopy for airway stenosis were clinically safe and effective.%目的 评价支气管镜介导下使用氩气刀与联合使用氩气刀及冷冻技术治疗气道狭窄,对比其有效性和安全性.方法 选择2008年7月至2010年4月门诊及住院治疗的气道狭窄患者,根据病因及气道内的镜下表现,判断具有支气管镜介导下氩气刀治疗指征的患者,随机进入氩气刀治疗组或氩气刀联合冷冻治疗组.追踪复查支气管镜,评价疗效.结果 14例患者根据病情需要另外联合支架置入和/或后装放疗,其中6例属氩气刀治疗组,氩气刀联合冷冻治疗组8例.40例患者共进行127次气管镜检查治疗.两组患者疗效相比差异无统计学意义(P=0.173),均未出现并发症.结论 气管镜介导下使用氩气刀与联合使用氩气刀及冷冻技术治疗气道狭窄,均能达到满意的临床疗效,安全可靠.

  6. Study on tracheal intubation related severe subglottic stenosis under laryngeal mask by using holmium laser combined with argon plasma coagulation and cryotherapy through bronchoscopy%喉罩下经支气管镜钬激光联合氩气刀和二氧化碳冷冻治疗儿童获得性重度声门下狭窄

    Institute of Scientific and Technical Information of China (English)

    许煊; 祝彬; 石苗茜; 任海丽; 封志纯

    2015-01-01

    目的:探讨2例气管插管相关性重度声门下狭窄喉罩下支气管镜诊断及介入治疗的操作方法、有效性及安全性。方法2例男性患儿,年龄分别为4和11个月,因气管插管后出现脱机困难及呼吸困难,经CT及支气管镜检查,诊断为气管插管相关的重度声门下狭窄,在对家长进行详细告知支气管镜下介入手术不可预知情况并由家长签字同意后,遂对2例患儿进行经喉罩支气管镜下钬激光联合氩气刀和二氧化碳( CO2)冷冻治疗,分析患儿的临床资料、并发症及术后转归、随访情况。结果2例手术过程顺利,例1术后紧贴声门下的肉芽组织被完全清除,2例患儿声门下环形狭窄完全解除,治疗前呼吸道狭窄处周长约2.5 mm,治疗后,周长达5.2 mm,4.0 mm支气管镜进出无障碍,术后气管导管均成功拔除,呼吸困难均明显改善。2例患儿治疗后即刻、7 d、30 d和90 d镜下检查结果示狭窄处开放良好。术中有血氧饱和度下降及心率增快或减慢,暂停操作及恢复给氧后立即恢复,术中及术后未见异常血流动力学改变,2例目前仍在随访中。结论经喉罩钬激光、氩气刀及CO2冷冻治疗可用于后天性肉芽组织增生引起的声门下狭窄,方法安全、有效,近期效果显著,远期仍在进一步随访评估。%Objective To explore the operating methods,the effectiveness and safety for 2 cases of tracheal in-tubation related severe subglottic stenosis under laryngeal mask by using bronchoscopy in the diagnosis and interven-tional treatment. Methods Two male patients ( age at 4 and 11 months) both had difficulty breathing and weaning failure after endotracheal intubation,who were diagnosed with severe subglottic stenosis through CT and bronchoscopy examination. All parents signed their consent after being fully informed of treatment risks. Two cases were treated under bronchoscopic holmium laser combined with argon plasma coagulation and

  7. Trimming of a Migrated Biliary Nitinol Stent Using Argon Plasma

    Directory of Open Access Journals (Sweden)

    Hiroyuki Matsubayashi

    2009-07-01

    Full Text Available Metallic stent migration is a well-known complication which cannot always be managed by removal or repositioning, especially in case of uncovered stent. We report a patient who developed obstructive jaundice due to migration of an expandable metallic stent (EMS inserted in the lower bile duct. Trimming of the EMS using argon plasma was performed, with the power setting of 60 W and 2.0 l/min of argon flow. The distal part of the EMS was removed and mechanical cleaning using balloon catheter was performed for remnant EMS. Without additional stent insertion, jaundice was relieved in a few days. No complication was recognized during the procedure and no recurrence of jaundice in the rest of his life.

  8. Temporal evolution of electron beam generated Argon plasma in pasotron device

    Science.gov (United States)

    Khandelwal, Neha; Pal, U. N.; Prakash, Ram; Choyal, Y.

    2016-10-01

    The plasma- assisted slow wave oscillator (PASOTRON) is a high power microwave source in which the electron beam in the interaction region is confined by the background plasma. The plasma is generated by impact ionization of background gas with the electron beam. A model has been developed for temporal evolution of Argon plasma in pasotron device. In this model, we consider electron beam of energy E interacting with Argon gas. The resulting ionization creates quasi neutral argon plasma composed of argon Ar atoms, singly ionized ions Ar+1and electrons having energy from 0 to E. Electron impact excitation, ionization, radiative decay, radiative recombination and three body recombination processes are considered in this model. Population of ground and excited states of argon atom, ground state of argon ion as well as the population of electron energy groups is calculated by solving time dependent rate equations. Temporal evolution of electron beam generated plasma is given.

  9. Numerical Modeling of an RF Argon-Silane Plasma with Dust Particle Nucleation and Growth

    Science.gov (United States)

    Girshick, Steven; Agarwal, Pulkit

    2012-10-01

    We have developed a 1-D numerical model of an RF argon-silane plasma in which dust particles nucleate and grow. This model self-consistently couples a plasma module, a chemistry module and an aerosol module. The plasma module solves population balance equations for electrons and ions, the electron energy equation under the assumption of a Maxwellian velocity distribution, and Poisson's equation for the electric field. The chemistry module treats silane dissociation and reactions of silicon hydrides containing up to two silicon atoms. The aerosol module uses a sectional method to model particle size and charge distributions. The nucleation rate is equated to the rates of formation of anions containing two Si atoms, and a heterogeneous reaction model is used to model particle surface growth. Aerosol effects considered include particle charging, coagulation, and particle transport by neutral drag, ion drag, electric force, gravity and Brownian diffusion. Simulation results are shown for the case of a 13.56 MHz plasma at a pressure of 13 Pa and applied RF voltage of 100 V (amplitude), with flow through a showerhead electrode. These results show the strong coupling between the plasma and the spatiotemporal evolution of the nanoparticle cloud.

  10. 氩气刀配合分叉型被膜金属支架置入治疗气管隆突处狭窄16例%Argon plasma coagulation combined with bifurcated metal stents for treatment of airway stenosis in the carinal region A 16-case analysis

    Institute of Scientific and Technical Information of China (English)

    王洪武; 周云芝; 马洪明; 罗凌飞; 李晶; 邹珩; 李冬妹

    2009-01-01

    纳入16例气管隆突处气道狭窄患者,其中良性病变4例,恶件病变12例.对气道内病变先用氩等离子体凝固清除,随后放置气道分叉型金属支架.所选支架均为国产Z型不锈钢被膜支架.L型及I型支架均在软质气管镜引导下放置,Y型支架在气管镜和透视结合下放置.氩等离子体凝固治疗前气管、左、右主支气管的阻塞程度分别为(58.8±9.1)%,(67.4±7.4)%及(69.6±8.9)%,氩等离子体凝固首次消融后的阻塞程度分别为(7.5±2.4)%,(19.4±4.1)%及(27.6±5.4)%.所有患者胸闷、气憋症状均有明显改善,气促指数降低,体能状况Kamofsky评分增高.12例患者一次成功放置支架,其中9例为Y型:4例放置失败,其中2例肺癌患者隆突较宽,Y型支架难以置入,改用L型+I型.患者中位生存时间为10个月,平均生存时间为13个月.结果提示,氩等离子体凝固结合分叉型被膜金属支架置入治疗气管隆突处狭窄可以改善患者梗阻症状,提高生活质量.%A total of 16 patients with airway stenosis including benign lesion (n=4) and malignant disease (n=12) were treated with argon plasma coagulation (APC) and Z-type covered retrievable metallic stent.L-and I-type stents were placed by guidance of brenchoscope,while Y-type stent was placed by the guidance of both bronchoscope and fluoroscope.Airway stenosis was from (58.8 +9.1)% before APC to (7.5±2.4)% after APC in tracheal,from (67.4±7.4)% to (19.4±4.1)% in left main bronchus,from (69.6±8.9)% to (27.6±5.4)% in right main bronchus.Symptoms of chest distress and breathlessness were improved remarkably,tachypnea indexes were decreased,but Kamofsky performance scope were increased.Twelve stents were successfully installed by the first time,including 9 Y-shape;otherwise,4 stents failed to be installed because the carinal was too wide to insert the Y-shape stent in two patients with lung cancer,finally,L+I type stents were used.Median survival time after successful

  11. A Thermodynamic Model for Argon Plasma Kernel Formation

    Directory of Open Access Journals (Sweden)

    James Keck

    2010-11-01

    Full Text Available Plasma kernel formation of argon is studied experimentally and theoretically. The experiments have been performed in a constant volume cylindrical vessel located in a shadowgraph system. The experiments have been done in constant pressure. The energy of plasma is supplied by an ignition system through two electrodes located in the vessel. The experiments have been done with two different spark energies to study the effect of input energy on kernel growth and its properties. A thermodynamic model employing mass and energy balance was developed to predict the experimental data. The agreement between experiments and model prediction is very good. The effect of various parameters such as initial temperature, initial radius of the kernel, and the radiation energy loss have been investigated and it has been concluded that initial condition is very important on formation and expansion of the kernel.

  12. Nanotextured Shrink Wrap Superhydrophobic Surfaces by Argon Plasma Etching

    Directory of Open Access Journals (Sweden)

    Jolie M. Nokes

    2016-03-01

    Full Text Available We present a rapid, simple, and scalable approach to achieve superhydrophobic (SH substrates directly in commodity shrink wrap film utilizing Argon (Ar plasma. Ar plasma treatment creates a stiff skin layer on the surface of the shrink film. When the film shrinks, the mismatch in stiffness between the stiff skin layer and bulk shrink film causes the formation of multiscale hierarchical wrinkles with nano-textured features. Scanning electron microscopy (SEM images confirm the presence of these biomimetic structures. Contact angle (CA and contact angle hysteresis (CAH measurements, respectively, defined as values greater than 150° and less than 10°, verified the SH nature of the substrates. Furthermore, we demonstrate the ability to reliably pattern hydrophilic regions onto the SH substrates, allowing precise capture and detection of proteins in urine. Finally, we achieved self-driven microfluidics via patterning contrasting superhydrophilic microchannels on the SH Ar substrates to induce flow for biosensing.

  13. Argon plasma immersion ion implantation of polystyrene films

    Energy Technology Data Exchange (ETDEWEB)

    Kondyurin, A. [Applied and Plasma Physics, School of Physics (A28), University of Sydney, New South Wales 2006 (Australia)], E-mail: kond@mailcity.com; Gan, B.K.; Bilek, M.M.M.; McKenzie, D.R.; Mizuno, K. [Applied and Plasma Physics, School of Physics (A28), University of Sydney, New South Wales 2006 (Australia); Wuhrer, R. [Microstructural Analysis Unit, University of Technology Sydney, P.O. Box 123, Broadway, NSW 2007 (Australia)

    2008-04-15

    Plasma immersion ion implantation (PIII), using bias voltages of 5, 10, 15 and 20 kV in an argon plasma and fluences in the range of 2 x 10{sup 14}-2 x 10{sup 16} ions/cm{sup 2}, was applied to 100 nm polystyrene films coated on silicon wafer substrates. The etching kinetics and structural changes induced in the polystyrene films were investigated with ellipsometry, Raman and FTIR spectroscopies, optical and scanning electron microscopies, atomic force microscopy and contact angle measurements. Effects such as carbonisation, oxidation and cross-linking were observed and their dependence on the applied bias voltage is reported. Variations in the etching rate during the PIII process and its relationship to carbonisation of the modified surface layer are explored.

  14. Nonthermal atmospheric argon plasma jet effects on Escherichia coli biomacromolecules.

    Science.gov (United States)

    Hosseinzadeh Colagar, Abasalt; Memariani, Hamed; Sohbatzadeh, Farshad; Valinataj Omran, Azadeh

    2013-12-01

    Nonthermal atmospheric plasma jet, a promising technology based on ionized gas at low temperatures, can be applied for disinfection of contaminated surfaces. In this study, Escherichia coli cells and their macromolecules were exposed to the nonthermal atmospheric argon plasma jet for different time durations. Total protein, genomic DNA, and malondialdehyde (MDA) levels of E. coli were assessed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and silver staining; agarose gel electrophoresis; and measurement of absorbance at 534 nm, respectively. After exposure, the spectroscopic results of liquid samples indicated that the survival reduction of E. coli can reach to 100 % in an exposure time of 600 s. Moreover, inactivation zones of E. coli, DNA degradation, and MDA levels were significantly increased. Additionally, banding patterns of total protein were changed and amino acid concentrations increased following ninhydrin test. The experimental results suggest that the nonthermal plasma could serve as an effective instrument for both sterilizing E. coli and degrading macromolecules from the surface of the objects being sterilized.

  15. Alternating current electrical properties of Argon plasma treated jute

    Directory of Open Access Journals (Sweden)

    Md. Masroor Anwer

    2012-09-01

    Full Text Available Low temperature plasma (LTP treatment, a kind of environment friendly surface modification technique, was applied to biodegradable and environment friendly jute fibre with the use of nonpolymerizing gas, namely argon, at various discharge power levels and exposure times with a definite flow rate. Scanning electron microscopy (SEM microphotographs reveal that the roughness of the fibre surfaces increases with the increase of discharge power and exposure time. This is caused due to the bombardment of high energetic ions on the fibre surface and the fibres become sputtered. The capacitance and the electrical conductance of raw and LTP treated jute fibre were measured as a function of frequency at room temperature. The dielectric constant, conductivity, dielectric loss-tangent and the surface morphology of raw and LTP treated jute as a function of frequency were studied at room temperature. It was observed that for all the samples the dielectric constant almost constant at lower frequencies and then decreases gradually in the high frequency region. In addition, dielectric constant increases with the increase of plasma treatment time as well as discharge power. It is also observed for all the samples that the conductivity increases as the frequency increases with a lower slope in the low frequency region and with a higher slope in the higher frequency region. In addition, the conductivity decreases with the increase of plasma exposure time as well as discharge power. The conductivity increases with frequency due to the hopping mechanism of electrons. The dependence of the dielectric loss-tangent with frequency at different treatment times and discharge powers for all the jute samples show small relaxation peaks in the very low frequency region. The dielectric loss-tangent decreases with the increase of both plasma treatment time and discharge power. In addition, the relaxation peaks are shifted to the higher frequency region as the plasma treatment

  16. Nonthermal Argon Plasma Generator and Some Potential Applications

    Directory of Open Access Journals (Sweden)

    Bunoiu M.

    2015-12-01

    Full Text Available A laboratory - made nonthermal plasma generator is presented. It has a diameter of 0.020 m and length of 0.155 m and contains two electrodes. The first electrode is a 2% Th-W alloy, 0.002 m in diameter bar, centred inside the generator’s body by means of a four channel teflon piece; the other three channels, 0.003 m in diameter, are used for Ar supply. The second electrode is a nozzle of 0.002 m - 0.008 m diameter and 0.005m length. A ~500 kV/m electric field is generated between the two electrodes by a high frequency source (13.56 MHz ±5%, equipped with a OT-1000 (Tungsram power triode. For Ar flows ranging from 0.00008 m3/s to 0.00056 m3/s, a plasma jet of length not exceeding 0.015 m and temperature below 315 K is obtained. Anthurium andraeanumis sample , blood matrix, human hair and textile fibers may be introduced in the plasma jet. For time periods of 30 s and 60 s, various effects like, cell detexturization, fast blood coagulation or textile fiber or hair cleaning and smoothing are obtained. These effects are presented and discussed in the paper.

  17. Course of organized structures in thermal plasma inside and outside argon plasma torch

    Science.gov (United States)

    Gruber, Jan; Sonsky, Jiri; Hlina, Jan

    2016-09-01

    Arc chamber of direct-current (dc) argon plasma torch and area just above the nozzle outside of this dc plasma torch were observed by hi-speed camera. System of reflecting mirrors and transparent silica arc chamber walls were used to obtain simultaneous records of both i) cathode area with electric arc inside the plasma torch and ii) nozzle exit with resulting plasma jet outside the plasma torch. Such experimental arrangement allowed us to track localized repeating patterns (organized structures) in the arc chamber and in the plasma flow. Identification of various organized structures - for different experimental conditions - according to their origin and typical development is presented in this paper. Impact of 300 Hz ripple in arc current was compared between different areas of the plasma. Additional simultaneous observation of plasma flow in the same system by series of photodiodes was used for verification of the results. The work was possible with institutional support RVO:61388998.

  18. Collisional-Radiative Modeling of Free-Burning Arc Plasma in Argon

    Science.gov (United States)

    2013-06-01

    COLLISIONAL-RADIATIVE MODELING OF FREE-BURNING ARC PLASMA IN ARGON M. Baeva  , D. Uhrlandt, S. Gorchakov Leibniz Institute for Plasma...S) AND ADDRESS(ES) Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Strasse 2, 17489 Greifswald, Germany 8. PERFORMING

  19. Surface compositional changes in GaAs subjected to argon plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Surdu-Bob, C.C.; Sullivan, J.L.; Saied, S.O.; Layberry, R.; Aflori, M

    2002-12-30

    X-ray photoelectron spectroscopy (XPS) has been employed to study surface compositional changes in GaAs (1 0 0) subjected to argon plasma treatment. The experimental results have been explained in terms of predicted argon ion energies, measured ion densities and etch rates. A model is proposed for the processes taking place at the surface of GaAs in terms of segregation, sputtering and surface relaxation. Stopping and range of ions in matter (SRIM) code has also been employedan aid to identification of the mechanisms responsible for the compositional changes. Argon plasma treatment induced surface oxidation at very low energies and sputtering and surface damage with increasing energy.

  20. Influence the loading effect on modification of PET film and fiber by Argon Plasma

    Science.gov (United States)

    Vasilkin, D. P.; Shikova, T. G.; Titov, V. A.; Smirnov, S. A.; Kuzmicheva, L. A.

    2017-01-01

    Poly(ethylene terepthalate) films and fabrics were modified by low-pressure argon plasma at different area of samples been treated. Contact angles for water and glycerol were measured and surface energy was calculated for film surface characterization. Height of water capillary rise was measured for fabric. The changes in chemical structure of surface layer were analyzed by ATR-FTIR method. Influence of sample area on non-homogeneity of plasma modification was shown. Some experiments were performed with polypropylene treatment in flowing plasma afterglow to confirm the reactions of oxygen active species originated from gas products of poly(ethylene terepthalate) etching in argon plasma.

  1. Surface modification of poly (vinyl chloride) by long-distance and direct argon RF plasma

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper reports the effects of long- distance and direct argon radio frequency (RF) plasma surface treatment on polyvinyl chloride (PVC) films in terms of changes in surface wettability and surface chemistry. The surface properties are characterized by the water contact angle measurement, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The mechanism is further analyzed and the role of all kinds of active species, e.g. electrons, ions and free radicals involved in plasma surface modification is further evaluated. Results show that the long-distance and direct RF plasma treatments modify the PVC surface in morphology and composition, and both modifications cause surface oxidation of PVC films, in the forming of functional groups enhancing polymer wettability. The effect of the long-distance argon RF plasma is more notable. This suggests that long-distance argon RF plasma could restrain the ion and electron eroding effect and enhance free radical reaction.

  2. Influence of Additive Gas on Electrical and Optical Characteristics of Non-equilibrium Atmospheric Pressure Argon Plasma Jet%Influence of Additive Gas on Electrical and Optical Characteristics of Non-equilibrium Atmospheric Pressure Argon Plasma Jet

    Institute of Scientific and Technical Information of China (English)

    费小猛; Shin-ichi KURODA; Yuki KONDO; Tamio MORI; Katsuhiko HOSOI

    2011-01-01

    Electrical and optical properties of an argon plasma jet were characterized. In particular, effects of an additive gas, namely nitrogen or oxygen, on these properties were studied in detail. The plasma jet was found to be of a glow-like discharge, which scarcely changed upon the injection of an additive gas, either directly or through a glass capillary. Optical emission spectroscopy characterization revealed that excited argon atoms were the predominant active species in this plasma jet. Metastable argon atoms were highly quenched, and N2(C3yIu) became the main energy carrier following nitrogen injection. When oxygen was added to the afterglow zone through a glass capillary, no significant quenching effect was observed and the number of oxygen atoms decreased with the increase in oxygen concentration. Finally, to demonstrate an application of this plasma jet, a high-density polyethylene surface was treated with argon, argon/nitrogen, and argon/oxygen plasmas.

  3. Characterization of an atmospheric double arc argon-nitrogen plasma source

    Science.gov (United States)

    Tu, X.; Chéron, B. G.; Yan, J. H.; Yu, L.; Cen, K. F.

    2008-05-01

    In the framework of studies devoted to hazardous waste destruction, an original dc double anode plasma torch has been designed and tested, which produces an elongated, weak fluctuation and reproducible plasma jet at atmospheric pressure. The arc instabilities and dynamic behavior of the double arc argon-nitrogen plasma jet are investigated through the oscillations of electrical signals by combined means of fast Fourier transform and Wigner distribution. In our experiment, the restrike mode is identified as the typical fluctuation behavior in an argon-nitrogen plasma jet. The Fourier spectra and Wigner distributions exhibit two characteristic frequencies of 150 Hz and 4.1 kHz, which reveals that the nature of fluctuations in the double arc argon-nitrogen plasma can be ascribed to the undulation of the power supply and both arc roots motion on the anode channels. In addition, the microscopic properties of the plasma jet inside and outside the arc chamber are investigated by means of optical emission spectroscopy, which yields excitation, electronic, rotational, and vibrational temperatures, as well as the electron number density. The results allow us to examine the validity criteria of a local thermodynamic equilibrium (LTE) state in the plasma arc. The measured electron densities are in good agreement with those calculated from the LTE model, which indicates that the atmospheric double arc argon-nitrogen plasma in the core region is close to the LTE state under our experimental conditions.

  4. Study of an Atmospheric Pressure Plasma Jet of Argon Generated by Column Dielectric Barrier Discharge

    Science.gov (United States)

    Nur, M.; Kinandana, A. W.; Winarto, P.; Muhlisin, Z.; Nasrudin

    2016-11-01

    An atmospheric of argon plasma jet was generated by using column dielectric barrier discharge has been investigated. In this study, argon gas was passed through the capillary column by regulating the flow rate of gas. This atmospheric pressure plasma jet (APPJ) was generated by a sinusoidal AC high voltage in the range of 0.4 kV to 10 kV and at frequencies of 15 kHz and 26 kHz. APPJ has been produced with flow rate of argon gas from 1 litter/min - 10 litters/min. The electric current has been taken with variation of voltage and each interval argon gas flow rate of 1 litter/min. The results show that electric current increase linearly and then it trends to saturation condition by the increasing of applied voltage. We found also that the length of the plasma jet increase by augmenting of applied voltage both for frequencies of 15 kHz and 26 kHz. Furthermore, our results show that length of plasma jet optimum for flow rate of argon gas of 2 litters/minute. In addition, we obtained that the larger applied voltage, the greater the temperature of the plasma jet.

  5. Experimental characterization of an argon laminar plasma jet at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Langlois-Bertrand, Emilie; De Izarra, Charles, E-mail: charles.de_izarra@univ-orleans.fr [Groupe de Recherche sur l' Energetique des Milieux Ionises, UMR6606 Universite d' Orleans - CNRS, Faculte des Sciences, Site de Bourges, rue Gaston Berger, BP 4043, 18028 BOURGES Cedex (France)

    2011-10-19

    This paper deals with a dc laminar pure argon plasma jet operating at atmospheric pressure in ambient air that was experimentally studied in order to obtain temperature and velocity. Plasma jet temperature was evaluated by optical emission spectroscopy and the plasma jet velocity was determined by various methods using a pressure sensor. It is shown that the maximum plasma jet temperature is 15 000 K and the maximum plasma jet velocity is 250 m s{sup -1} at the plasma jet centre. Finally, a study of the ambient air amount entrained into the plasma jet is presented.

  6. Coherent and incoherent Thomson scattering on an argon/hydrogen microwave plasma torch with transient behaviour

    Science.gov (United States)

    Obrusník, A.; Synek, P.; Hübner, S.; van der Mullen, J. J. A. M.; Zajíčková, L.; Nijdam, S.

    2016-10-01

    A new method of processing time-integrated coherent Thomson scattering spectra is presented, which provides not only the electron density and temperature but also information about the transient behaviour of the plasma. Therefore, it is an alternative to single-shot Thomson scattering measurements as long as the scattering is coherent. The method is applied to a microwave plasma torch operating in argon or a mixture of argon with hydrogen at atmospheric pressure. Electron densities up to 8\\cdot {{10}21} m-3 (ionization degree above 10-3) were observed, which is more than two times higher than presented in earlier works on comparable discharges. Additionally, a parametric study with respect to the argon/hydrogen ratio and the input power was carried out and the results are discussed together with earlier Stark broadening measurements on the same plasma.

  7. Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: An open, randomized, prospective, multicenter, parallel-group trial

    DEFF Research Database (Denmark)

    Fischer, Lars; Seiler, Christoph M.; Broelsch, Christoph E.

    2011-01-01

    Background: The aim of this trial was to confirm previous results demonstrating the efficacy and safety of a fixed combination tissue sealant versus argon beam coagulation (ABC) treatment in liver resection. Methods: This trial was designed as an international, multicenter, randomized, controlled...... points were drainage duration, volume, and content. Adverse events were collected to evaluate the safety of treatments. The trial was registered internationally (Eudract number 2008-006407-23). Results: Among 119 patients (60 TachoSil and 59 ABC) randomized in 10 tertiary care centers in Europe, the mean...

  8. Influence of dissociative recombination on the LTE of argon high-frequency plasmas at atmospheric pressure

    CERN Document Server

    Sainz, A; García, M C; Calzada, M D; Sainz, Abel; Margot, Joelle; Garcia, Maria Carmen; Calzada, Maria Dolores

    2004-01-01

    This work presents a few preliminary results from a collisional-radiative (CR) model intended to describe an argon microwave (2.45 GHz) plasma at atmospheric pressure. This model aims to investigate the influence of dissociative recombination products on the Saha-Boltzmann plasma equilibrium. The model is tested through comparison with experimental results obtained in an argon plasma column generated by a traveling electromagnetic surface-wave, which is suitable to perform a parametric investigation of the plasma. It is shown that dissociative recombination predominantly populates the 4s levels and the ground state. It is further observed that it strongly influences the population of the levels, specially those of lower energy. However, the higher levels (close to the ionization limit) appear to be in equilibrium whatever the plasma density. This allows assuming that the excitation temperature Texc determined from the upper levels in the atomic system in the Boltzmann-plot is equal to Te.

  9. CFD Simulation of a Hydrogen/Argon Plasma Jet Reactor for Coal Pyrolysis

    Institute of Scientific and Technical Information of China (English)

    CHEN H. G.; XIE K. C.

    2004-01-01

    A Computational Fluid Dynamics (CFD) model was formulated for DC arc hydrogen/argon plasma jet reactors used in the process of the thermal H2/Ar plasma pyrolysis of coal to acetylene. In this model, fluid flow, convective heat transfer and conjugate heat conductivity are considered simultaneously. The error caused by estimating the inner-wall temperature of a reactor is avoided. The thermodynamic and transport properties of the hydrogen/argon mixture plasma system, which are usually expressed by a set of discrete dats, are fitted into expressions that can be easily implemented in the program. The effects of the turbulence are modeled by two standard k-s equations. The temperature field and velocity field in the plasma jet reactor were calculated by employing SIMPLEST algorithm. The knowledge and insight obtained are useful for the design improvement and scale-up of plasma reactors.

  10. Changes in Dietary Fat Content Rapidly Alters the Mouse Plasma Coagulation Profile without Affecting Relative Transcript Levels of Coagulation Factors.

    Directory of Open Access Journals (Sweden)

    Audrey C A Cleuren

    Full Text Available Obesity is associated with a hypercoagulable state and increased risk for thrombotic cardiovascular events.Establish the onset and reversibility of the hypercoagulable state during the development and regression of nutritionally-induced obesity in mice, and its relation to transcriptional changes and clearance rates of coagulation factors as well as its relation to changes in metabolic and inflammatory parameters.Male C57BL/6J mice were fed a low fat (10% kcal as fat; LFD or high fat diet (45% kcal as fat; HFD for 2, 4, 8 or 16 weeks. To study the effects of weight loss, mice were fed the HFD for 16 weeks and switched to the LFD for 1, 2 or 4 weeks. For each time point analyses of plasma and hepatic mRNA levels of coagulation factors were performed after overnight fasting, as well as measurements of circulating metabolic and inflammatory parameters. Furthermore, in vivo clearance rates of human factor (F VII, FVIII and FIX proteins were determined after 2 weeks of HFD-feeding.HFD feeding gradually increased the body and liver weight, which was accompanied by a significant increase in plasma glucose levels from 8 weeks onwards, while insulin levels were affected after 16 weeks. Besides a transient rise in cytokine levels at 2 weeks after starting the HFD, no significant effect on inflammation markers was present. Increased plasma levels of fibrinogen, FII, FVII, FVIII, FIX, FXI and FXII were observed in mice on a HFD for 2 weeks, which in general persisted throughout the 16 weeks of HFD-feeding. Interestingly, with the exception of FXI the effects on plasma coagulation levels were not paralleled by changes in relative transcript levels in the liver, nor by decreased clearance rates. Switching from HFD to LFD reversed the HFD-induced procoagulant shift in plasma, again not coinciding with transcriptional modulation.Changes in dietary fat content rapidly alter the mouse plasma coagulation profile, thereby preceding plasma metabolic changes, which

  11. Ionic Wind Phenomenon and Charge Carrier Mobility in Very High Density Argon Corona Discharge Plasma

    Science.gov (United States)

    Nur, M.; Bonifaci, N.; Denat, A.

    2014-04-01

    Wind ions phenomenon has been observed in the high density argon corona discharge plasma. Corona discharge plasma was produced by point to plane electrodes and high voltage DC. Light emission from the recombination process was observed visually. The light emission proper follow the electric field lines that occur between point and plane electrodes. By using saturation current, the mobilities of non-thermal electrons and ions have been obtained in argon gas and liquid with variation of density from 2,5 1021 to 2 1022 cm-3. In the case of ions, we found that the behaviour of the apparent mobility inversely proportional to the density or follow the Langevin variation law. For non-thermal electron, mobility decreases and approximately follows a variation of Langevin type until the density <= 0,25 the critical density of argon.

  12. Removal of Pendant Groups of Vinyl Polymers by Argon Plasma Treatment

    NARCIS (Netherlands)

    Groenewoud, L.M.H.; Terlingen, J.G.A.; Engbers, G.H.M.; Feijen, J.

    1999-01-01

    Poly(acrylic acid) (PAAc) and poly(vinyl chloride) (PVC) were treated with an argon plasma to create unsaturated bonds at the surface. By use of X-ray photoelectron spectroscopy and Fourier transform infrared measurements, it was shown that the pendant groups of these polymers are removed by the arg

  13. Arc Root Motions in an Argon-Hydrogen Direct-Current Plasma Torch at Reduced Pressure

    Institute of Scientific and Technical Information of China (English)

    HUANG He-Ji; PAN Wen-Xia; WU Cheng-Kang

    2008-01-01

    Arc root motions in generating dc argon hydrogen plasma at reduced pressure are optically observed using a high-speed video camera. The time resolved angular position of the arc root attachment point is measured and analysed. The arc root movement is characterized as a chaotic and jumping motion along the circular direction on the anode surface.

  14. On the plasma chemistry of a cold atmospheric argon plasma jet with shielding gas device

    Science.gov (United States)

    Schmidt-Bleker, Ansgar; Winter, Jörn; Bösel, André; Reuter, Stephan; Weltmann, Klaus-Dieter

    2016-02-01

    A novel approach combining experimental and numerical methods for the study of reaction mechanisms in a cold atmospheric \\text{Ar} plasma jet is introduced. The jet is operated with a shielding gas device that produces a gas curtain of defined composition around the plasma plume. The shielding gas composition is varied from pure {{\\text{N}}2} to pure {{\\text{O}}2} . The density of metastable argon \\text{Ar}≤ft(4\\text{s}{{,}3}{{\\text{P}}2}\\right) in the plasma plume was quantified using laser atom absorption spectroscopy. The density of long-living reactive oxygen and nitrogen species (RONS), namely {{\\text{O}}3} , \\text{N}{{\\text{O}}2} , \\text{NO} , {{\\text{N}}2}\\text{O} , {{\\text{N}}2}{{\\text{O}}5} and {{\\text{H}}2}{{\\text{O}}2} , was quantified in the downstream region of the jet in a multipass cell using Fourier-transform infrared spectroscopy (FTIR). The jet produces a turbulent flow field and features guided streamers propagating at several \\text{km}~{{\\text{s}}-1} that follow the chaotic argon flow pattern, yielding a plasma plume with steep spatial gradients and a time dependence on the \\text{ns} scale while the downstream chemistry unfolds within several seconds. The fast and highly localized electron impact reactions in the guided streamer head and the slower gas phase reactions of neutrals occurring in the plasma plume and experimental apparatus are therefore represented in two separate kinetic models. The first electron impact reaction kinetics model is correlated to the LAAS measurements and shows that in the guided streamer head primary reactive oxygen and nitrogen species are dominantly generated from \\text{Ar}≤ft(4\\text{s}{{,}3}{{\\text{P}}2}\\right) . The second neutral species plug-flow model hence uses an \\text{Ar}≤ft(4\\text{s}{{,}3}{{\\text{P}}2}\\right) source term as sole energy input and yields good agreement with the RONS measured by FTIR spectroscopy.

  15. Compact cryogenic source of periodic hydrogen and argon droplet beams for relativistic laser-plasma generation

    Energy Technology Data Exchange (ETDEWEB)

    Fraga, R. A. Costa; Kalinin, A.; Kuehnel, M.; Schottelius, A. [Institut fuer Kernphysik, J. W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt am Main (Germany); Hochhaus, D. C.; Neumayer, P. [EMMI Extreme Matter Institute and Research Division, GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); FIAS Frankfurt Institute for Advanced Studies, J. W. Goethe-Universitaet, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main (Germany); Polz, J. [Institut fuer Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Kaluza, M. C. [Institut fuer Optik und Quantenelektronik, Max-Wien-Platz 1, 07743 Jena (Germany); Helmholtz-Institut Jena, Froebelstieg 3, 07743 Jena (Germany); Grisenti, R. E. [Institut fuer Kernphysik, J. W. Goethe-Universitaet, Max-von-Laue-Str. 1, 60438 Frankfurt am Main (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany)

    2012-02-15

    We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art high-power lasers in which a precise synchronization between the laser pulses and the droplets is mandatory. We show this by irradiating argon droplets with multi-terawatt pulses.

  16. Rotational and Vibrational Temperatures of Atmospheric Double Arc Argon-Nitrogen Plasma

    Institute of Scientific and Technical Information of China (English)

    YAN Jian-Hua; TU Xin; MA Zeng-Yi; CEN Ke-Fa; B.G.Chéron

    2007-01-01

    The spectroscopic technique is employed to study the emission of atmospheric argon-nitrogen plasma jet generated by an original dc double anode plasma torch. The molecular bands of the N(+2) first negative system are observed at the torch exit and chosen to evaluate the rotational and vibrational temperatures in comparison with the simulated spectra. The excitation temperature (Texc≈9600 K) is determined from the Boltzmann plot method. The results show that the rotational, vibrational, electron and kinetic temperatures are in good agreement with one another, which indicates that the core region of atmospheric double arc argon-nitrogen plasma jet at the torch exit is close to the local thermodynamic equilibrium state under our experimental conditions.

  17. The influence of methane/argon plasma composition on the formation of the hydrogenated amorphous carbon films

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hsin-Hung [Department of Materials Science and Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan (China); Liao, Jiunn-Der, E-mail: jdliao@mail.ncku.edu.t [Department of Materials Science and Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan (China); Weng, Chih-Chiang; Hsieh, Jui-Fu; Chang, Chia-Wei [Department of Materials Science and Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan (China); Lin, Chao-Hsien; Cho, Ting-Pin [Metal Industries Development and Research Centre, 1001 Kaonan Highway, Kaohsiung 811, Taiwan (China)

    2011-01-03

    The quality of the a-C:H films was particularly correlated with the mixed ratio of methane/argon plasma. For a constant supply of energy and flowing rate, the optical emission from H{sub {alpha}} intensity linearly increased with the addition of methane in argon plasma, while that from intensities of radiation of diatmoic radicals (CH*and C{sub 2}*) exponentially decreased. For the a-C:H films, the added methane in argon plasma tended to raise the quantity of hydrogenated carbon or sp{sup 3} C-H structure, which exponentially decreased the nano-hardness and friction coefficient of the films. In contrast, the electric resistance of the films enlarged dramatically with the increase of the methane content in argon plasma. It is therefore advantageous to balance the mechanical properties and electrical resistance of the a-C:H film by adjusting plasma composition in the course of the film-growing process.

  18. Surface modification of ultra-high molecular weight polyethylene (UHMWPE) by argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Liu Hengjun; Pei Yanan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Xie Dong [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031 (China); Deng Xingrui [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Leng, Y.X., E-mail: yxleng@263.net [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Jin Yong, E-mail: jyct@163.com [Interventional Therapy Department, The Second Affiliated Hospital, Soochow University, Suzhou 215004 (China); Huang Nan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China)

    2010-04-01

    In this work, argon (Ar) plasma generated by microwave electron cyclotron resonance (MWECR) has been used to modify the UHMWPE in order to increase the wear resistance. The results showed that the wettability, anti-scratch and wear resistance of UHMWPE treated by the Ar plasma had been improved, comparing with native UHMWPE. The FTIR and XPS spectra indicated the improvement of wettability should come from the oxygen based functional groups generated on the surface of UHMWPE. The improvement of anti-scratch and wear resistance may come from the enhancement of crosslinking of UHMWPE by Ar plasma treatment.

  19. New level-resolved collision data for neutral argon, benchmarked against the ALEXIS plasma experiment

    Science.gov (United States)

    Arnold, Nicholas; Loch, Stuart; Ballance, Connor; Thomas, Ed

    2016-10-01

    Performing spectroscopic measurements of emission lines in low temperature laboratory plasmas is challenging because the plasma is often neutral-dominated and not in thermal equilibrium. The densities and temperatures are such that coronal models do not apply; meaning that generalized collisional-radiative (GCR) methods must be employed to theoretically analyze atomic processes. However, for most noble gases, detailed, level-resolved atomic data for neutral and low-charge states does not exist in the literature. We report on a new project, where we use existing atomic physics codes to calculate level-resolved atomic data for neutral and low charge states of argon and compare with previously published, term-resolved theoretical results. In addition, we use the Atomic Structure and Data Analysis (ADAS) suite of codes to calculate a GCR model for low temperature neutral argon, which we compare to published measurements of argon optical emission cross sections. Finally, we compare synthetic spectra generated from our data with observations taken from the Auburn Linear Experiment for Instability Studies (ALEXIS) in an attempt to develop new optical plasma diagnostics for electron temperature and plasma density measurements. This project is supported by the U.S. Department of Energy. Grant Number: DE-FG02-00ER54476.

  20. Influence of argon plasma treatment on polyethersulphone surface

    Indian Academy of Sciences (India)

    N L Singh; S M Pelagade; R S Rane; S Mukherjee; U P Deshpande; V Ganeshan; T Shripathi

    2013-01-01

    Polyethersulphone (PES) was modified to improve the hydrophilicity of its surface, which in turn helps in improving its adhesive property. The modified PES surface was characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and Vicker’s microhardness measurement. The contact angles of the modified PES reduces from 49° to 10° for water. The surface free energy (SFE) calculated from measured contact angles increases from 66.3 to 79.5 mJ/m2 with the increase in plasma treatment time. The increase in SFE after plasma treatment is attributed to the functionalization of the polymer surface with hydrophilic groups. The XPS analysis shows that the ratio of O/C increases from 0.177 to 0.277 for modified PES polymer. AFM shows that the average surface roughness increases from 6.9 nm to 23.7 nm due to the increase in plasma treatment time. The microhardness of the film also increases with plasma treatment.

  1. [Investigation on the Spectral Characteristics of a Plasma Jet in Atmospheric Argon Glow Discharge].

    Science.gov (United States)

    Li, Xue-chen; Zhang, Chun-yan; Li, Ji-yuan; Bao, Wen-ting

    2015-12-01

    Plasma jet is a kind of important plasma source at atmospheric pressure. In recent years, it becomes an important hot topic in the field of low temperature plasma. In this paper, using a tungsten needle and a tungsten wire mesh, a direct-current excited jet is developed to operate in argon at atmospheric pressure. In the atmospheric pressure argon, the plasma jet can produce a stable plasma plume. By using the method of emission spectroscopy, the parameters of the plasma plume are investigated. The discharge emits dazzling white light from the area between the tungsten needle electrode and the wire mesh electrode. A plasma plume with a flame shape appears outside the tungsten wire mesh electrode. For a constant value of voltage (U = 13.5 kV), the length of the plasma plume increases with the gas flow rate. For a constant value of the gas flow rate(10 L · min⁻¹), the length of the plasma plume increases with the voltage. The voltage is inversely proportional to the current under the constant gas flow rate. In other words, the voltage decreases with the discharge current, which indicates that a glow discharge is formed in the plasma jet. Optical emission spectrum in 300 to 800 nm is collected from the direct-current excited plasma jet. By Boltzmann plot method, the excited electron temperature of the plasma plume is investigated as a function of the applied voltage or the gas flow rate. Results show that the excited electron temperature increases with decreasing applied voltage under the constant gas flow. Moreover, it increases with decreasing the gas flow under the constant voltage. Based on the discharge theory, these experimental phenomena are explained qualitatively. These results are of great importance to the development of atmospheric pressure uniform discharge plasma source and its application in industrial field.

  2. Risk assessment of a cold argon plasma jet in respect to its mutagenicity.

    Science.gov (United States)

    Wende, K; Bekeschus, S; Schmidt, A; Jatsch, L; Hasse, S; Weltmann, K D; Masur, K; von Woedtke, T

    2016-03-01

    Cold atmospheric pressure plasmas represent a favorable option for the treatment of heat sensitive materials and human or animal tissue. Beneficial effects have been documented in a variety of medical conditions, e.g., in the treatment of chronic wounds. It is assumed that the main mechanism of the plasma's efficacy is mediated by a stimulating dissipation of energy via radiation and/or chemical energy. Although no evidence on undesired side effects of a plasma treatment has yet been presented, skepticism toward the safety of the exposure to plasma is present. However, only little data regarding the mutagenic potential of this new treatment option is available. Accordingly, we investigated the mutagenic potential of an argon plasma jet (kinpen) using different testing systems in accordance with ISO norms and multiple cell lines: a HPRT1 mutation assay, a micronucleus formation assay, and a colony formation assay. Moderate plasma treatment up to 180 s did not increase genotoxicity in any assay or cell type investigated. We conclude that treatment with the argon plasma jet kinpen did not display a mutagenic potential under the test conditions applied and may from this perspective be regarded as safe for the use in biomedical applications.

  3. Surface Modification of Poly Vinyl Chloride (PVC) Using Low Pressure Argon and Oxygen Plasma

    Science.gov (United States)

    Mahmood, Ghoranneviss; Sheila, Shahidi; Jakub, Wiener

    2010-04-01

    In this study, commercial poly vinyl chloride (PVC) films were treated by oxygen and argon plasmas in a cylindrical glass tube which was surrounded by a DC variable magnetic field, with different sample positions in the plasma reactor and also different exposure durations. Effects of the plasma treatment on the hydrophilic properties of the films were studied by measuring the water drop contact angle on the surface of the samples. The surface topography of the untreated and plasma treated films was analyzed and compared by atomic force microscopy (AFM). The optical characteristic changes in treated samples were investigated using reflective spectrophotometry. Also, the chemical changes which appeared on the surface of the samples were investigated using Fourier transform infrared spectroscopy (FTIR). The results show that the plasma treated PVC becomes more hydrophilic with an enhanced wettability. A sharp decrease in the water contact angle may also be a consequence of the surface texturization. The aging effect on wettability of the samples was also investigated. The results show that the effect of oxygen plasma on the surface properties of the samples is more pronounced compared with that of argon plasma.

  4. Numerical Analysis of Amirkabir Plasma Focus (APF) Device for Neon and Argon Gases

    Science.gov (United States)

    Niknam Sharak, M.; Goudarzi, S.; Raeisdana, A.; Jafarabadi, M.

    2013-04-01

    In this paper the experimental results in different working conditions in Amirkabir Plasma Focus (APF) Device have been compared with the numerical results of a two-dimensional simulation code based on Lee's model. The experiments were done with pure Neon and Argon as operating gases over a wide range of working conditions (gas pressures and discharge voltages). It is observed that by a proper choice for values of the efficiency factors, comparison between numerical and experimental results shows a good agreement.

  5. Enhanced Field Emission from Argon Plasma-Treated Ultra-sharp α-Fe2O3Nanoflakes

    Directory of Open Access Journals (Sweden)

    Zhang JX

    2009-01-01

    Full Text Available Abstract Hematite nanoflakes have been synthesized by a simple heat oxide method and further treated by Argon plasmas. The effects of Argon plasma on the morphology and crystal structures of nanoflakes were investigated. Significant enhancement of field-induced electron emission from the plasma-treated nanoflakes was observed. The transmission electron microscopy investigation shows that the plasma treatment effectively removes amorphous coating and creates plenty of sub-tips at the surface of the nanoflakes, which are believed to contribute the enhancement of emission. This work suggests that plasma treatment technique could be a direct means to improve field-emission properties of nanostructures.

  6. 氩离子凝固术联合腹腔镜食管裂孔疝修补术加胃底折叠术治疗食管裂孔疝合并Barrett食管的疗效观察%Clinical study of argon plasma coagulation combined with laparoscopic hiatal hernia repair and fundoplication in the treatment of hiatal hernia with Barrett esophagus

    Institute of Scientific and Technical Information of China (English)

    张成; 克力木; 李义亮; 苏福增; 李慧灵; 王志; 李赞林; 艾克拜尔; 阿扎提

    2015-01-01

    Objective To investigate the clinical efficacy of argon plasma coagulation (APC) combined with laparoscopic hiatal hernia repair and fundoplication in the treatment of hiatal hernia associated with Barrett esophagus.Methods A total of 61 cases of hiatal hernias with Barrett esophagus from June 2010 to January 2014 in the Department of Minimal Invasive Surgery, Hernia and Abdominal wall Surgery, People's Hospital of Xinjiang Uyhur Autonomous Region were prospectively enrolled and were randomly allocated into two groups by computer system.Twenty-nine patients received esomeprazole 40 mg/d after APC treatment for 8 weeks (APC with medicine group).Thirty-two patients underwent laparoscopic hiatal hernia repair and Nissen fundoplication after APC treatment (APC with surgery group).All the patients were reviewed by gastroscope and pathologic examination at half a year and one year after operation respectively.Differences of disease improvement and recurrence between the two groups were evaluated.Results In APC with medicine group, the Barrett's esophagus was relieved after one or two times of APC treatment, however, gastroscope and pathology revealed recurrence of Barrett's esophagus in 7 cases at half a year, and cumulative 16 cases of recurrences were detected after one year follow-up (16/29, 55.2%).In APC with surgery group, only one patient had recurrent Barrett's esophagus at half a year, and a total of two at one year follow-up by gastroscope examination(2/32, 6.3%).Significantly low recurrence rate of Barrett's esophagus was observed in APC with surgery group compared to APC with medicine group(P<0.01).Furthermore, recurrent hiatal hernia was detected in only one case in APC with surgery group.No esophageal cancer was found in both groups during follow-up.Conclusion APC combined with laparoscopic hiatal hernia repair and fundoplication is an ideal method for patients with hiatal hernia and Barrett's esophagus.%目的 探讨氩离子凝固术(APC)联合腹

  7. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII......:Ag) or estimated with an amidolytic method (FVII:Am). We have investigated whether FVII:Am is a valuable alternative to FVII:Ag. FVII:Ag and FVII:Am were measured in 147 plasma samples from blood donors, patients on oral anticoagulant therapy, postmenopausal women on hormone replacement therapy, in postprandial...

  8. On the effect of treating poly(acrylic acid) with argon and tetrafluoromethane plasmas: Kinetics and degradation mechanism

    NARCIS (Netherlands)

    Terlingen, Johannes G.A.; Takens, Gijsbert A.J.; Gaag, van der Frederik J.; Hoffman, Allan S.; Feijen, Jan

    1994-01-01

    Poly(acrylic acid) (PAAc) films were treated with either an argon or a tetrafluoromethane (CF4) plasma and subsequently analyzed with X-ray photoelectron spectroscopy (XPS). PAAc films were decarboxylated during both types of plasma treatments. In addition, during the CF4 plasma treatment, the PAAc

  9. Pulsed microwave-driven argon plasma jet with distinctive plume patterns resonantly excited by surface plasmon polaritons

    Institute of Scientific and Technical Information of China (English)

    陈兆权; 殷志祥; 夏广庆; 洪伶俐; 胡业林; 刘明海; 胡希伟

    2015-01-01

    Atmospheric lower-power pulsed microwave argon cold plasma jets are obtained by using coaxial transmission line resonators in ambient air. The plasma jet plumes are generated at the end of a metal wire placed in the middle of the dielec-tric tubes. The electromagnetic model analyses and simulation results suggest that the discharges are excited resonantly by the enhanced electric field of surface plasmon polaritons. Moreover, for conquering the defect of atmospheric argon filamentation discharges excited by 2.45-GHz continued microwave, the distinctive patterns of the plasma jet plumes can be maintained by applying different gas flow rates of argon gas, frequencies of pulsed modulator, duty cycles of pulsed microwave, peak values of input microwave power, and even by using different materials of dielectric tubes. In addition, the emission spectrum, the plume temperature, and other plasma parameters are measured, which shows that the proposed pulsed microwave plasma jets can be adjusted for plasma biomedical applications.

  10. Novel Diamond Films Synthesis Strategy: Methanol and Argon Atmosphere by Microwave Plasma CVD Method Without Hydrogen

    Science.gov (United States)

    Yang, Li; Jiang, Caiyi; Guo, Shenghui; Zhang, Libo; Gao, Jiyun; Peng, Jinhui; Hu, Tu; Wang, Liang

    2016-09-01

    Diamond thin films are grown on silicon substrates by only using methanol and argon mixtures in microwave plasma chemical vapor deposition (MPCVD) reactor. It is worth mentioning that the novel strategy makes the synthesis reaction works smoothly without hydrogen atmosphere, and the substrates temperature is only 500 °C. The evidence of surface morphology and thickness under different time is obtained by characterizing the samples using scanning electron microscopy (SEM). X-ray diffractometer (XRD) spectrum reveals that the preferential orientation of (111) plane sample is obtained. The Raman spectra indicate that the dominant component of all the samples is a diamond. Moreover, the diamond phase content of the targeted films was quantitatively analyzed by X-ray photoelectron spectroscopy (XPS) method, and the surface roughness of diamond films was investigated by atomic force microscope (AFM). Meanwhile, the possible synthesis mechanism of the diamond films in methanol- and argon-mixed atmosphere was discussed.

  11. Characterization of a copper spark discharge plasma in argon atmosphere used for nanoparticle generation

    Science.gov (United States)

    Kohut, Attila; Galbács, Gábor; Márton, Zsuzsanna; Geretovszky, Zsolt

    2017-04-01

    Spark discharge nanoparticle generation is a dynamically developing application of discharge plasmas. In the present study a spark plasma used for nanoparticle generation is characterized by means of spatially and temporally resolved optical emission spectroscopy (OES) supplemented by fast imaging. The data acquired during the generation of copper nanoparticles in argon ambient is used to describe the spatial and temporal evolution of the species in the spark gap and to derive plasma parameters such as excitation temperature and electron concentration on one hand, and the concentration of the Cu species eroded by a single spark on the other. It is shown that temporally and spatially resolved OES together with a simple equilibrium model are efficient tools to estimate the characteristics of the spark discharge plasma that typically exists in spark discharge nanoparticle generators.

  12. Investigating the Mutagenicity of a Cold Argon-Plasma Jet in an HET-MN Model

    Science.gov (United States)

    Bender, Claudia; Benkhai, Hicham; Sckell, Axel; Below, Harald; Stope, Matthias B.; Kramer, Axel

    2016-01-01

    Objective So-called cold physical plasmas for biomedical applications generate reactive oxygen and nitrogen species and the latter can trigger DNA damage at high concentrations. Therefore, the mutagenic risks of a certified atmospheric pressure argon plasma jet (kINPen MED) and its predecessor model (kINPen 09) were assessed. Methods Inner egg membranes of fertilized chicken eggs received a single treatment with either the kINPen 09 (1.5, 2.0, or 2.5 min) or the kINPen MED (3, 4, 5, or 10 min). After three days of incubation, blood smears (panoptic May-Grünwald-Giemsa stain) were performed, and 1000 erythrocytes per egg were evaluated for the presence of polychromatic and normochromic nuclear staining as well as nuclear aberrations and binucleated cells (hen’s egg test for micronuclei induction, HET-MN). At the same time, the embryo mortality was documented. For each experiment, positive controls (cyclophosphamide and methotrexate) and negative controls (NaCl-solution, argon gas) were included. Additionally, the antioxidant potential of the blood plasma was assessed by ascorbic acid oxidation assay after treatment. Results For both plasma sources, there was no evidence of genotoxicity, although at the longest plasma exposure time of 10 min the mortality of the embryos exceeded 40%. The antioxidant potential in the egg’s blood plasma was not significantly reduced immediately (p = 0.32) or 1 h (p = 0.19) post exposure to cold plasma. Conclusion The longest plasma treatment time with the kINPen MED was 5–10 fold above the recommended limit for treatment of chronic wounds in clinics. We did not find mutagenic effects for any plasma treatment time using the either kINPen 09 or kINPen MED. The data provided with the current study seem to confirm the lack of a genotoxic potential suggesting that a veterinary or clinical application of these argon plasma jets does not pose mutagenic risks. PMID:27584003

  13. Coagulation parameters as a guide for fresh frozen plasma transfusion practice: A tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    Wan Haslindawani W

    2010-01-01

    Full Text Available Introduction: The appropriate use of blood and blood products means the transfusion of safe blood products only to treat a condition leading to significant morbidity or mortality, which cannot be prevented or managed effectively by other means. The safety and effectiveness of transfusion depend on the appropriate clinical use of blood and blood products. This study was conducted to review the practice of fresh frozen plasma usage (FFP for transfusion, based on the coagulation profile, requested by various departments in the Hospital Universiti Sains Malaysia (HUSM. Methodology: A retrospective review of blood bank records and coagulation profile results of the patients given FFP from October to December 2006, in Hospital USM was undertaken. The criteria set by the College of American Pathologists in 1994, were used as the guidelines. Results: One thousand six hundred and ninety-eight units of FFP were used during this study period. Only 806 (47.47% FFP units were deemed appropriate. 20.38% were based on studies without any coagulation tests prior to transfusion and 21.13% were transfused for mild prolongation of coagulation test results. About 6.41% requested FFP in the setting of normal coagulation results. Conclusion: Our results showed that a significant proportion of the FFP transfusion was not guided by the coagulation profile. We recommend that a continuous education on FFP transfusion may help to guide the appropriate request for FFP.

  14. Frequency of cell treatment with cold microwave argon plasma is important for the final outcome

    Science.gov (United States)

    Sysolyatina, E.; Vasiliev, M.; Kurnaeva, M.; Kornienko, I.; Petrov, O.; Fortov, V.; Gintsburg, A.; Petersen, E.; Ermolaeva, S.

    2016-07-01

    The purpose of this work was to establish the influence of a regime of cold microwave argon plasma treatments on the physiological characteristics of human fibroblasts and keratinocytes. We used three regimes of plasma application: a single treatment, double treatment with a 48 h interval, and daily treatments for 3 d. Cell proliferation after plasma application was quantified in real time, and immunohistochemistry was used to establish the viability of the cells and determine changes in their physiology. It was established that the frequency of cell treatments is important for the outcome. In the samples treated with single plasma application and double plasma applications with a 48 h interval, a 42.6% and 32.0% increase was observed in the number of cells, respectively. In addition, there were no signs of deoxyribonucleic acid breaks immediately after plasma application. In contrast, plasma application increased the accumulation of cells in the active phases of the cell cycle. The activation of proliferation correlated with a decrease in the level of β-galactosidase, a senescence marker. This could be due to cell renovation after plasma application. Daily treatment decreased cell proliferation up to 29.1% in comparison with the control after 3 d.

  15. Experimental investigations of the plasma radial uniformity in single and dual frequency capacitively coupled argon discharges

    Science.gov (United States)

    Zhao, Kai; Liu, Yong-Xin; Gao, Fei; Liu, Gang-Hu; Han, Dao-Man; Wang, You-Nian

    2016-12-01

    In the current work, the radial plasma density has been measured by utilizing a floating double probe in single and dual frequency capacitively coupled argon discharges operated in a cylindrical reactor, aiming at a better understanding of electromagnetic effects and exploring a method of improving the radial uniformity. The experimental results indicate that for single-frequency plasma sustained at low pressure, the plasma density radial profile exhibits a parabolic distribution at 90 MHz, whereas at 180 MHz, the profile evolves into a bimodal distribution, and both cases indicate poor uniformities. With increasing the pressure, the plasma radial uniformity becomes better for both driving frequency cases. By contrast, when discharges are excited by two frequencies (i.e., 90 + 180 MHz), the plasma radial profile is simultaneously influenced by both sources. It is found that by adjusting the low-frequency to high-frequency voltage amplitude ratio β, the radial profile of plasma density could be controlled and optimized for a wide pressure range. To gain a better plasma uniformity, it is necessary to consider the balance between the standing wave effect, which leads to a maximum plasma density at the reactor center, and the edge field effect, which is responsible for a maximum density near the radial electrode edge. This balance can be controlled either by selecting a proper gas pressure or by adjusting the ratio β.

  16. Waves generated in the vicinity of an argon plasma gun in the ionosphere

    Science.gov (United States)

    Cahill, L. J., Jr.; Arnoldy, R. L.; Lysak, R. L.; Peria, W.; Lynch, K. A.

    1993-01-01

    Wave and particle observations were made in the close vicinity of an argon plasma gun carned to over 600 km altitude on a sounding rocket. The gun was carned on a subpayload, separated from the main payload early in the flight. Twelve-second argon ion ejections were energized alternately with a peak energy of 100 or 200 eV. They produced waves, with multiple harmonics, in the range of ion cyclotron waves, 10 to 1000 Hz at rocket altitudes. Many of these waves could not be identified as corresponding to the cyclotron frequencies of any of the ions, argon or ambient, known to be present. In addition, the wave frequencies were observed to rise and fall and to change abruptly during a 12-s gun operation. The wave amplitudes, near a few hundred Hertz, were of the order of O. 1 V/m. Some of the waves may be ion-ion hybrid waves. Changes in ion populations were observed at the main payload and at the subpayload during gun operations. A gun-related, field-aligned, electron population also appeared.

  17. Optical Characteristics Investigation of the Cold Argon Plasma Jet for the Medical Applications

    Science.gov (United States)

    Nguyen-Kuok, Shi; Malakhov, Yury; Bach, Sy Minh; Korotkikh, Ivan

    2016-09-01

    The medical setup was designed for the treatment of wounds, disinfection of inflammation, for the destruction of damaged cells. The results of experimental determination of the optical characteristics of Argon cold plasma at atmospheric pressure are presented in the paper. The main components of the experimental setup are plasma torch, spectrometer, photo-electron multiplier, oscilloscope, gas consumption QAr = 1 - 20 l/min. Spectrum of the plasma jet is obtained using the grating spectrometer Spectra with radiometric calibration, operating in the visible range λ = 380 - 760 nm. The sun-blind photodetector was used for determination of the intensity of radiation in the UV range λ = 190 - 380 nm. The emission spectrum consists of a continuous radiation and the emissions of atoms and ions ArI and ArII. The analysis of spectral lines was carried out.

  18. Spatially Resolved Measurements of a Double Layer in an Argon Helicon Plasma

    Science.gov (United States)

    Aguirre, Evan; Siddiqui, Umair; McKee, John; Scime, Earl

    2015-11-01

    We report 2-dimensional, spatially resolved observations of a double layer in an expanding helicon plasma. These new measurements investigate the origins of previously observed multiple ion beam populations in the downstream plasma. We use Laser Induced Fluorescence (LIF) to measure the ion velocity distribution functions (IVDFs) of argon ions and neutrals both parallel and perpendicular to the background magnetic field and an rf-compensated Langmuir probe to determine the local plasma potential. These are the first multi-dimensional LIF measurements of ion acceleration in a current-free double layer and were obtained with a recently installed, internal scanning probe system in the HELIX-LEIA experimental facility. This work is supported by US National Science Foundation grant number PHY-1360278.

  19. Investigation of forbidden transitions in argon ions. [in laboratory plasma for solar corona simulation

    Science.gov (United States)

    Jalufka, N. W.

    1976-01-01

    An attempt has been made to observe the visible forbidden argon coronal lines at 553.6 nm (Ar X), 691.7 nm (Ar XI), 847.6 nm (Ar XIII), and 441.2 nm (Ar XIV) in a deuterium-argon plasma produced in a large theta pinch. The electron temperature (250 eV) and the electron density (5 by 10 to the 16th power per cu cm) were measured by Thomson scattering of ruby laser radiation. This temperature is adequate to produce ionization stages up to Ar XIV, as was verified by photographic observation of Ar XIV lines. No line corresponding to the coronal lines was observed from the high-temperature plasma, but lines with wavelengths very nearly identical to those of two of the forbidden transitions were observed; these lines were due to allowed transitions of Ar II in a cooler portion of the plasma. Calculation of rate coefficients in the Coulomb-Born approximation shows that for laboratory experiments, electron collisions are much more important than radiative decay in depopulating the upper state of the forbidden lines.

  20. Particle-in-Cell Modeling of Magnetized Argon Plasma Flow Through Small Mechanical Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Adam B. Sefkow and Samuel A. Cohen

    2009-04-09

    Motivated by observations of supersonic argon-ion flow generated by linear helicon-heated plasma devices, a three-dimensional particle-in-cell (PIC) code is used to study whether stationary electrostatic layers form near mechanical apertures intersecting the flow of magnetized plasma. By self-consistently evaluating the temporal evolution of the plasma in the vicinity of the aperture, the PIC simulations characterize the roles of the imposed aperture and applied magnetic field on ion acceleration. The PIC model includes ionization of a background neutral-argon population by thermal and superthermal electrons, the latter found upstream of the aperture. Near the aperture, a transition from a collisional to a collisionless regime occurs. Perturbations of density and potential, with mm wavelengths and consistent with ion acoustic waves, propagate axially. An ion acceleration region of length ~ 200-300 λD,e forms at the location of the aperture and is found to be an electrostatic double layer, with axially-separated regions of net positive and negative charge. Reducing the aperture diameter or increasing its length increases the double layer strength.

  1. Numerical simulations of a nonequilibrium argon plasma in a shock-tube experiment

    Science.gov (United States)

    Cambier, Jean-Luc

    1991-01-01

    A code developed for the numerical modeling of nonequilibrium radiative plasmas is applied to the simulation of the propagation of strong ionizing shock waves in argon gas. The simulations attempt to reproduce a series of shock-tube experiments which will be used to validate the numerical models and procedures. The ability to perform unsteady simulations makes it possible to observe some fluctuations in the shock propagation, coupled to the kinetic processes. A coupling mechanism by pressure waves, reminiscent of oscillation mechanisms observed in detonation waves, is described. The effect of upper atomic levels is also briefly discussed.

  2. Compact Cryogenic Source of Periodic Hydrogen and Argon Droplet Beams for Intense Laser-Plasma Generation

    CERN Document Server

    Fraga, R A Costa; Kühnel, M; Hochhaus, D C; Schottelius, A; Polz, J; Kaluza, M C; Neumayer, P; Grisenti, R E

    2011-01-01

    We present a cryogenic source of periodic streams of micrometer-sized hydrogen (H2) and argon (Ar) droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art low-repetition rate high-power lasers, in which a precise synchronization between the laser pulses and the droplets is mandatory. We demonstrate this explicitly by irradiating Ar droplets with pulses from a Petawatt laser.

  3. Analysis of tree leaves, bark and wood by sequential inductively coupled argon plasma atomic emission spectrometry

    Science.gov (United States)

    Verbeek, A. A.

    The analysis of extracts from tree leaf, bark and wood samples for Ca, Mg, K, Na, P, Mn, Fe, Al, B, Cu and Zn by inductively coupled argon plasma sequential emission spectrometry is described. Recovery percentages for simulated tree extracts and for spiked tree samples are presented together with typical analysis values for a leaf and a wood sample. The choice of analytical line for each element is discussed and spectral interferences, not listed in the ICP tables of Boumans, of Cu on the 214.9 nm line of P and of Fe on the 249.7 nm line of B are noted.

  4. Development of a microplate coagulation assay for Factor V in human plasma

    Directory of Open Access Journals (Sweden)

    Samis John A

    2011-06-01

    Full Text Available Abstract Background Factor V (FV in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. Methods The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. Results The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC, the FV 1-stage, 2-stage (With activation by thrombin, and total (2-stage activity - 1-stage activity activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP. The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. Conclusions The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in

  5. Characteristics of a long and stable filamentary argon plasma jet generated in ambient atmosphere

    Science.gov (United States)

    Teodorescu, M.; Bazavan, M.; Ionita, E. R.; Dinescu, G.

    2015-04-01

    We present a study of a long (up to 60 mm) and thin (600 μm) plasma jet generated at 13.56 MHz in argon expanding in an open atmosphere from inside of a thin glass tube. The discharge is operated with one annular external electrode on the tube, in the absence of any grounded electrode in the discharge proximity. The study comprises image, spectral and electrical measurements, aiming to define and understand the operating domains of this plasma jet source. Two plasma zones were identified, which coexist: a long filament accompanied by a diffuse discharge. The coexistence of these plasma zones was studied in the power-mass flow rate parameter space. An electric model is proposed, considering the jet as a radiating antenna, which allows the determination of the main electrical parameters like capacitance, resistance and active RF power dissipated in the discharge. The specific zones on the I-V characteristics were assigned to the operating domains observed visually. The spectral emission of plasma has been used to characterize the jet in respect to the gas temperature, excitation temperature and plasma density.

  6. Long-term spatio-temporal evolution of the dust distribution in dusty argon rf plasmas

    Science.gov (United States)

    Killer, Carsten; Greiner, Franko; Groth, Sebastian; Tadsen, Benjamin; Melzer, André

    2016-10-01

    The 3D dust distribution in dense dust clouds confined in argon rf plasmas is measured by a computed tomography (CT) technique based on the extinction of visible light. On the one hand, clouds of micron-sized particles were created by injecting standardized plastic particles into the plasma. On the other hand, sub-micron sized dust with well-defined properties is grown in situ in an argon acetylene mixture. Once created, both kinds of dust clouds decay in the course of minutes to hours. This decay is monitored by CT measurements. It is revealed that micro-dust clouds feature a drastic change of the dust distribution due to a size reduction of the dust. Dust clouds of sub-micron particles, in contrast, show a strong variation of the overall dust density while the relative dust distribution remains nearly unchanged. The evolution of the overall dust density is subject to two effects: the loss of particles due to an imperfect confinement and the reduction of the dust size via etching.

  7. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat [Department of Physics, Facuty of Science, Chulalongkorn University, Bangkok (Thailand); Plasma Technology and Nuclear Fusion Research Unit, Chulalongkorn University, Bangkok (Thailand)

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) can be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.

  8. Generation of uniform atmospheric pressure argon glow plasma by dielectric barrier discharge

    Indian Academy of Sciences (India)

    Raju Bhai Tyata; Deepak Prasad Subedi; Rajendra Shrestha; Chiow San Wong

    2013-03-01

    In this paper, atmospheric pressure glow discharges (APGD) in argon generated in parallel plate dielectric barrier discharge system is investigated by means of electrical and optical measurements. Using a high voltage (0–20 kV) power supply operating at 10–30 kHz, homogeneous and steady APGD has been observed between the electrodes with gap spacing from 0.5 mm to 2 mm and with a dielectric barrier of thickness 2 mm while argon gas is fed at a controlled flow rate of 11/min. The electron temperature and electron density of the plasma are determined by means of optical emission spectroscopy. Our results show that the electron density of the discharge obtained is of the order of 1016 cm-3 while the electron temperature is estimated to be 0.65 eV. The important result is that electron density determined from the line intensity ratio method and stark broadening method are in very good agreement. The Lissajous figure is used to estimate the energy deposited to the glow discharge. It is found that the energy deposited to the discharge is in the range of 20 to 25 $\\$J with a discharge voltage of 1.85 kV. The energy deposited to the discharge is observed to be higher at smaller gas spacing. The glow discharge plasma is tested to be effective in reducing the hydrophobicity of polyethylene film significantly.

  9. Modification of tapioca starch by non-chemical route using jet atmospheric argon plasma.

    Science.gov (United States)

    Wongsagonsup, Rungtiwa; Deeyai, Panakamol; Chaiwat, Weerawut; Horrungsiwat, Sawanee; Leejariensuk, Kesini; Suphantharika, Manop; Fuongfuchat, Asira; Dangtip, Somsak

    2014-02-15

    Non-chemical modification of tapioca starch was investigated using jet atmospheric argon plasma treatment. Two forms of starch slurry, i.e. granular starch (G) and cooked starch (C), were jet-treated by argon plasma generated by supplying input power of 50 W (denoted as G50 and C50 samples) and 100 W (denoted as G100 and C100 samples) for 5 min. Physical, rheological, and structural characteristics of the modified starch were investigated. The G50 and C100 samples had lower paste clarity but higher thermal stability and performed stronger gels (G50 only) compared to their control counterparts. On the other hand, the analyzed properties of the G100 and C50 samples showed the opposite trend. FTIR and (1)H NMR results revealed that the relative areas of COC and OH peaks were changed after the treatment. Cross-linking reaction seemed to predominantly take place for the G50 and C100 samples, whereas depolymerization predominated for the G100 and C50 samples.

  10. Aluminium metallisation of argon and oxygen plasma-modified polycarbonate thin film surfaces

    Science.gov (United States)

    Rastomjee, C. S.; Keil, M.; Sotobayashi, H.; Bradshaw, A. M.; Lamont, C. L. A.; Gador, D.; Umbach, E.

    1998-12-01

    The influence of plasma treatment on the metallisation of polycarbonate surfaces was studied using X-ray absorption spectroscopy (XAFS) and core level X-ray photoelectron spectroscopy (XPS). Thin films of two different molecules were chosen: bis-phenol-A polycarbonate with phenol endgroups (P-PC) prepared ex situ by the spin-coating technique onto MoTe 2{0001}surfaces, and the model compound bis-phenol-A polycarbonate ( n=1) with tert-butyl phenyl endgroups (tBP-PC) evaporated in situ in UHV onto Cu{110}, Ag{100} and Ag{111} surfaces with film thicknesses of up to several monolayers. Surfaces of untreated samples and of samples which were pre-treated with either an inert argon or a reactive oxygen microwave plasma were metallised with Al (evaporated by electron beam heating) at film thicknesses ranging from the sub-monolayer region up to several monolayers. For the untreated surface, XAFS and XPS spectra suggest that the Al reacts with the carbonate groups leading to a breaking of the CO double bonds (and/or a reduction in bond order) as well as formation of Al oxide, Al hydroxide and Al-O-C linkages. A study of the time-dependent oxidation of the evaporated Al leads to the conclusion that Al slowly diffuses to the reactive sites in the first few subsurface layers of the polymer. Argon plasma treatment of samples leads to a reduction in the number of carbonyl groups in the near surface region. After metal deposition a higher ratio of metallic, non-reacted, Al was observed covering the polycarbonate surface and the diffusion rate into the polymer bulk seems to be higher than in the case of the untreated surface. Oxygen plasma treatment leads to the creation of additional CO containing species which also react with the Al in the subsequent metallisation process. Here, the ratio of oxidised Al on the polymer surface is higher than observed for untreated and argon plasma pre-treated polymer surfaces.

  11. Generation of Cold Argon Plasma Jet at the End of Flexible Plastic Tube

    CERN Document Server

    Kostov, Konstantin G; Prysiazhnyi, Vadym

    2014-01-01

    This brief communication reports a new method for generation of cold atmospheric pressure plasma jet at the downstream end of a flexible plastic tube. The device consists of a small chamber where dielectric barrier discharge (DBD) is ignited in Argon. The discharge is driven by a conventional low frequency AC power supply. The exit of DBD reactor is connected to a commercial flexible plastic tube (up to 4 meters long) with a thin floating Cu wire inside. Under certain conditions an Ar plasma jet can be extracted from the downstream tube end and there is no discharge inside the plastic tube. The jet obtained by this method is cold enough to be put in direct contact with human skin without electric shock and can be used for medical treatment and decontamination.

  12. A comparison among optical emission spectroscopic methods of determining electron temperature in low pressure argon plasmas

    Institute of Scientific and Technical Information of China (English)

    Niu Tian-Ye; Cao Jin-Xiang; Liu Lei; Liu Jin-Ying; Wang Yan; Wang Liang

    2007-01-01

    In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas.

  13. Microwave diagnostic for the determination of the electron temperature of a low density shock-heated argon plasma

    Science.gov (United States)

    Schneider, C. P.; Exberger, R. J.

    1978-01-01

    The diffraction, defocusing and beam bending effects of microwaves transmitted through a bounded shock-heated argon plasma with low electron density are investigated with the purpose of developing an accurate method for electron temperature (Te) determination. This report describes the evaluation technique and presents results for an argon plasma with pressure between 3 and 10 torr, and T2 between 5500 and 9500 K. The electron temperature values obtained have a range of uncertainty between -20% and +10% only. The electron temperature is equal or lower by approximately 1000 K in comparison to the heavy particle temperature (T2).

  14. ULTRAVIOLET INDUCED MOTION OF A FLUORESCENT DUST CLOUD IN AN ARGON DIRECT CURRENT GLOW DISCHARGE PLASMA

    Energy Technology Data Exchange (ETDEWEB)

    Hvasta, M.G.; and Zwicker, A.

    2008-01-01

    Dusty plasmas consist of electrons, ions, neutrals and nm-μm sized particles commonly referred to as dust. In man-made plasmas this dust may represent impurities in a tokamak or plasma etching processing. In astrophysical plasmas this dust forms structures such as planetary rings and comet tails. To study dusty plasma dynamics an experiment was designed in which a 3:1 silica (<5 μm diameter) and fl uorescent dust mixture was added to an argon DC glow discharge plasma and exposed to UV radiation. This fl uorescent lighting technique offers an advantage over laser scattering (which only allows two-dimensional slices of the cloud to be observed) and is simpler than scanning mirror techniques or particle image velocimetry. Under typical parameters (P=150 mTorr, V anode= 100 V, Vcathode= -400 V, Itotal < 2mA) when the cloud is exposed to the UV light (100W, λ = 365 nm) the mixture fl uoresces, moves ~2mm towards the light source and begins rotating in a clockwise manner (as seen from the cathode). By calibrating a UV lamp and adjusting the relative intensity of the UV with a variable transformer it was found that both translational and rotational velocities are a function of UV intensity. Additionally, it was determined that bulk cloud rotation is not seen when the dust tray is not grounded while bulk translation is. This ongoing experiment represents a novel way to control contamination in man-made plasmas and a path to a better understanding of UV-bathed plasma systems in space..

  15. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    Science.gov (United States)

    Van Deynse, A.; Cools, P.; Leys, C.; De Geyter, N.; Morent, R.

    2015-02-01

    Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1-1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the discharge power, the concentrations of all oxygen containing groups such as Csbnd O, Cdbnd O and Osbnd Cdbnd O increase. Increasing the flow rate up to 1.25 slm results mainly in an increase in Osbnd Cdbnd O groups. However, from a flow rate of 1.25 slm on, the concentration of all oxygen groups again decreases. Based on these results, the appropriate settings for an efficient plasma treatment can easily be selected.

  16. Measurement of factor v activity in human plasma using a microplate coagulation assay.

    Science.gov (United States)

    Tilley, Derek; Levit, Irina; Samis, John A

    2012-09-09

    In response to injury, blood coagulation is activated and results in generation of the clotting protease, thrombin. Thrombin cleaves fibrinogen to fibrin which forms an insoluble clot that stops hemorrhage. Factor V (FV) in its activated form, FVa, is a critical cofactor for the protease FXa and accelerator of thrombin generation during fibrin clot formation as part of prothrombinase (1, 2). Manual FV assays have been described (3, 4), but they are time consuming and subjective. Automated FV assays have been reported (5-7), but the analyzer and reagents are expensive and generally provide only the clot time, not the rate and extent of fibrin formation. The microplate platform is preferred for measuring enzyme-catalyzed events because of convenience, time, cost, small volume, continuous monitoring, and high-throughput (8, 9). Microplate assays have been reported for clot lysis (10), platelet aggregation (11), and coagulation Factors (12), but not for FV activity in human plasma. The goal of the method was to develop a microplate assay that measures FV activity during fibrin formation in human plasma. This novel microplate method outlines a simple, inexpensive, and rapid assay of FV activity in human plasma. The assay utilizes a kinetic microplate reader to monitor the absorbance change at 405 nm during fibrin formation in human plasma (Figure 1) (13). The assay accurately measures the time, initial rate, and extent of fibrin clot formation. It requires only μl quantities of plasma, is complete in 6 min, has high-throughput, is sensitive to 24-80 pM FV, and measures the amount of unintentionally activated (1-stage activity) and thrombin-activated FV (2-stage activity) to obtain a complete assessment of its total functional activity (2-stage activity - 1-stage activity). Disseminated intravascular coagulation (DIC) is an acquired coagulopathy that most often develops from pre-existing infections (14). DIC is associated with a poor prognosis and increases mortality

  17. Transient electromagnetic behaviour in inductive oxygen and argon-oxygen plasmas

    Science.gov (United States)

    Chadwick, A. R.; Herdrich, G.; Kim, M.; Dally, B.

    2016-12-01

    In order to develop inductive electric propulsion as a flexible, throttleable technology for future space operations, a greater understanding of discharge transitions within the inductive plasma generator discharge chamber is required. This paper presents a non-intrusive method to determine the conditions under which transitions between the capacitive, low inductive, and high inductive regimes occur with greater accuracy, as well as determining the proportion of a single discharge cycle the plasma spends in either capacitive or inductive regime. Such a method allows a more robust method of classification of inductive discharges than previously available and can be applied to numerous gases. This approach presents an advantage over previous methods which relied on strongly radiating or thermally reactive gases to exhibit certain behaviour (due to the restriction of classical diagnostics on such high power sources) before a transition could be confirmed. This paper presents results from the proposed method applied to a pure oxygen plasma as well as two combinations of argon and oxygen (at 1:1 and 3:2 Ar:O2 volumetric ratios) in order to assess the tunability of electromagnetic regime transitions through modifications of gas composition rather than mechanical alterations. Transitions to the higher inductive mode were observed for much lower input powers for the argon-oxygen blends, as was expected, allowing final discharge conditions to occupy the inductive regime for 94% and 85% of a single discharge cycle for the 3:2 and 1:1 Ar:O2 mixtures, respectively. Pure oxygen achieved a maximum inductive proportion of 71% by comparison.

  18. Refreezing previously thawed fresh-frozen plasma. Stability of coagulation factors V and VIII:C.

    Science.gov (United States)

    Dzik, W H; Riibner, M A; Linehan, S K

    1989-09-01

    With the growth in autologous blood programs and the increased scrutiny of the indications for transfusion of fresh-frozen plasma (FFP), an increase has been seen in the number of occasions on which FFP was requested and thawed but then not transfused. The coagulation properties of FFP units that were refrozen and then rethawed were therefore studied. Fifty-eight units of plasma were studied, with each experimental unit of FFP paired with an identical control unit. Experimental units were frozen, stored at -65 degrees C, thawed, stored at 1 to 6 degrees C for various periods of time up to 24 hours, and then refrozen, stored at -65 degrees C, rethawed, and stored again in the refrigerator for up to 24 hours. Control units were frozen once at the time the experimental units were first frozen and thawed once at the time of the second thaw of the experimental units. Aliquots of plasma were sampled periodically and were later batch-tested for prothrombin time (PT), activated partial thromboplastin time (aPTT), and factor V and VIII:C activity. The results of coagulation testing of the twice-frozen plasmas were always within the normal range. There was a slight but statistically valid prolongation of the PT and aPTT and a decrease in the factor V and VIII:C levels for twice-frozen plasma compared with control plasma. The greatest decline occurred in the level of factor VIII:C. The measured deterioration in coagulation of twice-frozen FFP is unlikely to be of clinical importance. Refreezing FFP may eventually prove useful for rare donor, autologous, and massive transfusion programs.

  19. Experimental behaviour of a argon plasma, which is passed by a high current intensity, with different magnetic field configurations; Comportamiento experimental de un plasma de argon en diferentes configuraciones de campo magnetico y a elevadas corrientes

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, J.

    1964-07-01

    In a lineal discharge, the longitudinal and azimuthal magnetic fields produced by the current through the tube and the returning conductors, which have 4 different forms, are determined with a magnetic probe, which has a radial and longitudinal displacement. The plasma is produced discharging a 135{mu}F and 9 KV capacitor bank through Argon at 10{sup -}1 Torr. (Author) 5 refs.

  20. Spectroscopic diagnostics of electron temperature and energy conversion efficiency of laser-sustained plasma in flowing argon

    Science.gov (United States)

    Mazumder, J.; Krier, H.; Chen, X.

    1988-08-01

    Laser sustained plasmas are often formed during laser materials interaction. The University's 10 kW CW CO2 laser has been used to study argon plasmas for the application to laser supported propulsion and laser materials processing. The spectroscopic diagnostic method has been applied to study laser-sustained plasmas in 1 atmosphere pure argon gas flow with an f/7 on-axis laser focusing scheme. High flow speeds of 2 to 10 m/sec are achieved. Plasma electron temperatures distributions are determined from the 415.8 nm Ar1 line and its adjacent continuum intensities. Plasma core temperatures as high as 20,000 K are reported. The total absorption of the incident laser power and the radiation loss by the plasma are calculated from the temperature distribution. Results indicated that up to 86 percent of the incident laser power can be absorbed and nearly 60 percent of the incident laser power can be retained by the flowing argon gas to provide thrust. Further research is called for in the Laser Induced Fluorescence (LIF) technique for diagnostics of the downstream mixing zone and the plasma outer region. Experiments over a wider range of operating conditions, as well as multiple plasma testings, are required to find the optimum operating scheme.

  1. The effect of UV radiation from oxygen and argon plasma on the adhesion of organosilicon coatings on polypropylene

    Science.gov (United States)

    Jaritz, M.; Behm, H.; Hopmann, Ch; Kirchheim, D.; Mitschker, F.; Awakowicz, P.; Dahlmann, R.

    2017-01-01

    The influence of ultraviolet (UV) radiation from oxygen and argon pretreatment plasmas on a plastic substrate has not been fully understood yet. In particular, its influence on the adhesion properties has not been sufficiently researched so far. This paper addresses this issue by comparing the bond strength of a plasmapolymerized silicon organic coating (SiO x C y H z ) on polypropylene (PP) after oxygen and argon plasma pretreatment and pretreatment by UV radiation emitted by the same plasmas. The UV radiation is isolated from the other species from the plasma by means of a magnesium fluoride (MgF2) optical filter. It could be shown that UV radiation originating from an oxygen plasma has a significant impact on both substrate surface chemistry and coating adhesion. The same maximum bond strength enhancement can be reached by pretreating the polypropylene surface either with pulsed oxygen plasma, or with only the UV radiation from this oxygen plasma. Also, similar surface chemistry and topography modifications are induced. For argon plasma no significant influence of its UV radiation on the substrate could be observed in this study.

  2. On the Role of Metastable Argon in Cold Atmospheric Pressure Plasma Jets with Shielding Gas Device

    Science.gov (United States)

    Schmidt-Bleker, Ansgar; Winter, Jorn; Sousa, Joao Santos; Puech, Vincent; Weltmann, Klaus-Dieter; Reuter, Stephan; ZIK plasmatis at the INP Greifswald e. V. Team; Laboratoire de Physique des Gaz et des Plasmas (LPGP), CNRS; Université Paris-Sud Team

    2014-10-01

    Shielding gas devices are a valuable tool for controlling the reactive species output of Cold Atmospheric Pressure Plasma (CAPP) Jets for biomedical applications. In this work we investigate the effect of different shielding gas compositions using a CAPP jet (kinpen) operated with argon. As shielding gas various mixtures of N2 and O2 are used. Metastable argon (Ar*) has been quantified using laser absorption spectroscopy and was identified as an important energy carrier in the CAPP jets effluent. The Ar* excitation dynamics was studied using phase resolve optical emission spectroscopy. Based on these findings a kinetic model for the gas phase chemistry has been developed that uses the Ar* density and dynamics as input and yields densities of O3, NO2, HNO2, HNO3, N2O5, H2O2 and N2O produced by the CAPP jet for different shielding gas compositions. The results are in good agreement with Fourier-Transform Infrared Spectroscopy measurements on these species. Authors gratefully acknowledge the funding by German Federal Ministry of Education a Research (BMBF) (Grant # 03Z2DN12).

  3. Study of a contracted glow in low-frequency plasma-jet discharges operating with argon

    Energy Technology Data Exchange (ETDEWEB)

    Minotti, F.; Giuliani, L.; Xaubet, M.; Grondona, D. [Departamento de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, C1428EHA, Buenos Aires, Argentina and Instituto de Física del Plasma (INFIP), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad de Buenos Aires - UBA, C1428EHA, Buenos Aires (Argentina)

    2015-11-15

    In this work, we present an experimental and theoretical study of a low frequency, atmospheric plasma-jet discharge in argon. The discharge has the characteristics of a contracted glow with a current channel of submillimeter diameter and a relatively high voltage cathode layer. In order to interpret the measurements, we consider the separate modeling of each region of the discharge: main channel and cathode layer, which must then be properly matched together. The main current channel was modeled, extending a previous work, as similar to an arc in which joule heating is balanced by lateral heat conduction, without thermal equilibrium between electrons and heavy species. The cathode layer model, on the other hand, includes the emission of secondary electrons by ion impact and by additional mechanisms, of which we considered emission due to collision of atoms excited at metastable levels, and field-enhanced thermionic emission (Schottky effect). The comparison of model and experiment indicates that the discharge can be effectively sustained in its contracted form by the secondary electrons emitted by collision of excited argon atoms, whereas thermionic emission is by far insufficient to provide the necessary electrons.

  4. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    Energy Technology Data Exchange (ETDEWEB)

    Van Deynse, A., E-mail: Annick.VanDeynse@ugent.be [Department Industrial Technology and Construction, Faculty of Engineering & Architecture, Ghent University, Valentin Vaerwyckweg 1, 9000 Ghent (Belgium); Cools, P., E-mail: Pieter.Cools@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); Leys, C., E-mail: Christophe.Leys@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); De Geyter, N., E-mail: Nathalie.DeGeyter@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); Morent, R., E-mail: Rino.Morent@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium)

    2015-02-15

    Highlights: • Surface modification of polyethylene by an argon atmospheric pressure plasma jet. • Investigation of the influence of the applied power and argon flow rate. • Turbulence in the gas flow leads to a shorter afterglow. • Turbulence in the gas flow results in a lower wettability of the polyethylene. • Increasing the applied power increases the wettability of the polyethylene. - Abstract: Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1–1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the

  5. Exploring the electron density in plasmas induced by extreme ultraviolet radiation in argon

    CERN Document Server

    van der Horst, R M; Osorio, E A; Banine, V Y

    2015-01-01

    The new generation of lithography tools use high energy EUV radiation which ionizes the present background gas due to photoionization. To predict and understand the long term impact on the highly delicate mirrors It is essential to characterize these kinds of EUV-induced plasmas. We measured the electron density evolution in argon gas during and just after irradiation by a short pulse of EUV light at 13.5 nm by applying microwave cavity resonance spectroscopy. Dependencies on EUV pulse energy and gas pressure have been explored over a range relevant for industrial applications. Our experimental results show that the maximum reached electron density depends linearly on pulse energy. A quadratic dependence - caused by photoionization and subsequent electron impact ionization by free electrons - is found from experiments where the gas pressure is varied. This is demonstrated by our theoretical estimates presented in this manuscript as well.

  6. Energy spectrum of argon ions emitted from Filippov type Sahand plasma focus

    Science.gov (United States)

    Mohammadnejad, M.; Pestehe, S. J.; Mohammadi, M. A.

    2013-07-01

    The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy.

  7. Determination of {sup 233}U by inductively coupled argon plasma - atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Patwardhan, A.B.; Kulkarni, V.T.; Radhakrishnan, K.; Ramanujam, A.; Page, A.G. [Bhabha Atomic Research Centre, Bombay (India)

    1994-09-01

    The paper describes studies carried out for the determination of {sup 233}U at various stages during the recovery and purification of {sup 233}U from {sup 233}U-Al alloy scraps generated during the fabrication of {sup 233}U-Al alloy fuel. Employing a high resolution sequential spectrometer and Inductively Coupled argon Plasma (ICP) as the spectral excitation source, isotope shift for {sup 233}U with respect to {sup 238}U has been resolved and recorded. The shift for the 424.437 nm emission line of {sup 238}U is found to be of the order of 0.040 nm on the lower wavelength side for {sup 233}U and this isotopic effect has been utilised for the quantitative determination of {sup 233}U. The overall precision of the method is 5% RSD with the detection limit of 0.01 {mu}g/ml.

  8. Proton acceleration using doped Argon plasma density gradient interacting with relativistic CO2 -laser pulse

    Science.gov (United States)

    Sahai, Aakash; Ettlinger, Oliver; Hicks, George; Ditter, Emma-Jane; Najmudin, Zulfikar

    2016-10-01

    We investigate proton and light-ion acceleration driven by the interaction of relativistic CO2 laser pulses with overdense Argon or other heavy-ion gas targets doped with lighter-ion species. Optically shaping the gas targets allows tuning of the pre-plasma scale-length from a few to several laser wavelengths, allowing the laser to efficiently drive a propagating snowplow through the bunching in the electron density. Preliminary PIC-based modeling shows that the lighter-ion species is accelerated even without any significant motion of the heavier ions which is a signature of the Relativistically Induced Transparency Acceleration mechanism. Some outlines of possible experiments at the TW CO2 laser at the Accelerator Test Facility at Brookhaven National Laboratory are presented.

  9. Energy spectrum of argon ions emitted from Filippov type Sahand plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadnejad, M.; Pestehe, S. J.; Mohammadi, M. A. [Department of Atomic and Molecular Physics, Faculty of Physics, University of Tabriz, Postal Code 5166614766, Tabriz (Iran, Islamic Republic of); Research Institute for Applied Physics and Astronomy, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2013-07-15

    The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy.

  10. Radiative properties of argon-helium-nitrogen-carbon-cobalt-nickel plasmas used in CNT synthesis

    Science.gov (United States)

    Salem, D.; Hannachi, R.; Cressault, Y.; Teulet, Ph; Béji, L.

    2015-02-01

    This work presents the radiative properties of argon-helium-nitrogen-carbon-nickel-cobalt thermal plasmas by the computation of net emission coefficients (NECs) under the assumption of a local thermodynamic equilibrium and at temperature range 1000-20 000 K. These mixtures were often used in the study of carbon nanotubes (CNTs) synthesis with arc plasma which becomes one of the most useful techniques in terms of flexibility of carbon nanostructures produced with fewer defects. The values of NEC allow estimation of total radiation losses in plasmas, by taking into account the emission radiation resulting from the atomic continuum, the molecular continuum, the atomic lines and some molecular bands. Free-free transitions (Bremsstrahlung) and free-bound (electron-ion recombination), have been considered for the calculation of atomic continuum. For bound-bound transitions, natural, resonance, Van der Waals, Stark and Doppler effects have been taken into account in the calculation of the lines broadenings while the self-absorption of the resonance lines has been treated using their escape factors. Molecular continuum has been only considered for N2, C2 and CN molecules whereas we have only taken into account diatomic systems N2, \\text{N}2+ , CN and C2 for the emission of the molecular bands. The results obtained show that even for low concentrations of Ni and Co in the plasma, the NECs are modified and considerably increase only at a low temperature (T < 8000 K) and the major contribution in the total radiation arises from the lines emission. However, the effect of the thickness of the plasma on plasma radiation has been analysed based on the self absorption phenomenon of resonance lines.

  11. Introduction of sulfate groups on poly(ethylene) surfaces by argon plasma immobilization of sodium alkyl sulfates

    NARCIS (Netherlands)

    Lens, J.P.; Terlingen, J.G.A.; Engbers, G.H.M.; Feijen, J.

    1998-01-01

    Sulfate groups were introduced at the surface of poly(ethylene) (PE) samples. This was accomplished by immobilizing a precoated layer of either sodium 10-undecene sulfate (S11(:)) or sodium dodecane sulfate (SDS) on the polymeric surface by means of an argon plasma treatment. For this purpose, S11(:

  12. Superhydrophilic poly(L-lactic acid) electrospun membranes for biomedical applications obtained by argon and oxygen plasma treatment

    Science.gov (United States)

    Correia, D. M.; Ribeiro, C.; Botelho, G.; Borges, J.; Lopes, C.; Vaz, F.; Carabineiro, S. A. C.; Machado, A. V.; Lanceros-Méndez, S.

    2016-05-01

    Poly(L-lactic acid), PLLA, electrospun membranes and films were plasma treated at different times and power with argon (Ar) and oxygen (O2), independently, in order to modify the hydrophobic nature of the PLLA membranes. Both Ar and O2 plasma treatments promote an increase in fiber average size of the electrospun membranes from 830 ± 282 nm to 866 ± 361 and 1179 ± 397 nm, respectively, for the maximum exposure time (970 s) and power (100 W). No influence of plasma treatment was detected in the physical-chemical characteristics of PLLA, such as chemical structure, polymer phase or degree of crystallinity. On the other hand, an increase in the roughness of the films was obtained both with argon and oxygen plasma treatments. Surface wettability studies revealed a decrease in the contact angle with increasing plasma treatment time for a given power and with increasing power for a given time in membranes and films and superhydrophilic electrospun fiber membranes were obtained. Results showed that the argon and oxygen plasma treatments can be used to tailor hydrophilicity of PLLA membranes for biomedical applications. MTT assay results indicated that plasma treatments under Ar and O2 do not influence the metabolic activity of MC3T3-E1 pre-osteoblast cells.

  13. Structural characteristics of copper/hydrogenated amorphous carbon composite films prepared by microwave plasma-assisted deposition processes from methane-argon and acetylene-argon gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Thiery, F.; Pauleau, Y.; Grob, J.J.; Babonneau, D

    2004-11-01

    Copper/hydrogenated amorphous carbon (Cu/a-C:H) composite films have been deposited on silicon substrates by a hybrid technique combining microwave plasma-assisted chemical vapor deposition and sputter-deposition from methane-argon and acetylene-argon gas mixtures. The major objective of this work was to investigate the effect of the carbon gas precursor on the structural characteristics of Cu/a-C:H composite films deposited at ambient temperature. The major characteristics of CH{sub 4}-argon and C{sub 2}H{sub 2}-argon plasmas were analyzed by Langmuir probe measurements. The composition of films was determined by Rutherford backscattering spectroscopy, energy recoil detection analyses and nuclear reaction analyses. The carbon content in the films was observed to vary in the range 20-77 at.% and 7.5-99 at.% as the CH{sub 4} and C{sub 2}H{sub 2} concentrations in the gas phase increased from 10 to 100%, respectively. The atom number ratio H/C in the films was scattered approximately 0.4 whatever the carbon gas precursor used. The crystallographic structure and the size of copper crystallites incorporated in the a-C were determined by X-ray diffraction techniques. The copper crystallite size decreased from 20 nm in pure copper films to less than 5 nm in Cu/a-C:H films containing more than 40 at.% of carbon. Grazing incidence small angle X-ray scattering measurements were performed to investigate the size distribution and distance of copper crystallites as functions of the deposition parameters. The structural characteristics of copper crystallites were dependent on the hydrocarbon gas precursor used. The crystallite size and the width of the size distribution were homogeneous in films deposited from CH{sub 4}. Copper crystallites with an anisotropic shape were found in films deposited from C{sub 2}H{sub 2}. The major radicals formed in the plasma and condensed on the surface of growing films, namely CH and C{sub 2}H radicals for films produced from CH{sub 4} and C

  14. Particle Densities of the Atmospheric-Pressure Argon Plasmas Generated by the Pulsed Dielectric Barrier Discharges

    Science.gov (United States)

    Pan, Jie; Li, Li; Wang, Yunuan; Xiu, Xianwu; Wang, Chao; Song, Yuzhi

    2016-11-01

    Atmospheric-pressure argon plasmas have received increasing attention due to their high potential in many industrial and biomedical applications. In this paper, a 1-D fluid model is used for studying the particle density characteristics of the argon plasmas generated by the pulsed dielectric barrier discharges. The temporal evolutions of the axial particle density distributions are illustrated, and the influences of changing the main discharge conditions on the averaged particle densities are researched by independently varying the various discharge conditions. The calculation results show that the electron density and the ion density reach two peaks near the momentary cathodes during the rising and the falling edges of the pulsed voltage. Compared with the charged particle densities, the densities of the resonance state atom Arr and the metastable state atom Arm have more uniform axial distributions, reach higher maximums and decay more slowly. During the platform of the pulsed voltage and the time interval between the pulses, the densities of the excited state atom Ar* are far lower than those of the Arr or the Arm. The averaged particle densities of the different considered particles increase with the increases of the amplitude and the frequency of the pulsed voltage. Narrowing the discharge gap and increasing the relative dielectric constant of the dielectric also contribute to the increase of the averaged particle densities. The effects of reducing the discharge gap distance on the neutral particle densities are more significant than the influences on the charged particle densities. supported by Natural Science Foundation of Shandong Province, China (No. ZR2015AQ008), and Project of Shandong Province Higher Educational Science and Technology Program of China (No. J15LJ04)

  15. Investigations of laser-induced plasma in argon by Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Mendys, A., E-mail: agata.mendys@uj.edu.pl [Instytut Fizyki im. M. Smoluchowskiego, Uniwersytet Jagiellonski, ulica Reymonta 4, 30-059 Krakow (Poland); Dzierzega, K.; Grabiec, M. [Instytut Fizyki im. M. Smoluchowskiego, Uniwersytet Jagiellonski, ulica Reymonta 4, 30-059 Krakow (Poland); Pellerin, S. [GREMI - site de Bourges, Universite d' Orleans, CNRS, rue Gaston Berger BP 4043, 18028 Bourges (France); Pokrzywka, B. [Obserwatorium Astronomiczne na Suhorze, Uniwersytet Pedagogiczny, ulica Podchorazych 2, 30-084 Krakow (Poland); Travaille, G.; Bousquet, B. [Centre de Physique Moleculaire Optique et Hertzienne, Universite Bordeaux 1, 351 Cours de la Liberation, 33405 Talence CEDEX (France)

    2011-09-15

    The Thomson scattering method was applied to quantify the electron number density and temperature of a laser spark formed in argon. The laser spark was generated by focusing a 15 mJ beam from the second harmonic ({lambda}{sub L} = 532 nm) of a nanosecond Nd:YAG laser with an 80 mm focal length lens. Images of the spark emission were obtained for times between 1 ns and 20 {mu}s after the laser pulse in order to characterize its spatial evolution. The electron density and temperature for the core of the plasma plume at different instants of its evolution were determined from the Thomson scattered spectra of another nanosecond Nd:YAG laser (532 nm, 10 to 60 mJ/pulse). In the time interval between 400 ns and 10 {mu}s between the laser induced plasma and Thomson scattering probe pulses, we found n{sub e} and T{sub e} to decrease from 4.3 Multiplication-Sign 10{sup 23} m{sup -3} to 2.4 Multiplication-Sign 10{sup 22} m{sup -3} and from 50 700 K to 11 100 K, respectively. Special care was paid to the plasma disturbance by the probe laser pulse in Thomson scattering experiments due to absorption of laser photons by electrons through the inverse bremsstrahlung process.

  16. Two Dimensional LIF Measurements and Potential Structure of Ion Beam Formation in an Argon Helicon Plasma

    Science.gov (United States)

    Aguirre, Evan; Scime, Earl; Good, Timothy

    2016-10-01

    We report 2-dimensional, spatially resolved observations of ion beam formation in an expanding helicon plasma. Previous studies found that a current free double layer (CFDL) spontaneously arises at low pressure, below 1 mT. We use Laser Induced Fluorescence (LIF), a non-perturbative diagnostic to measure the ion velocity distribution functions (IVDFs) of argon ions both parallel and perpendicular to the background magnetic field. We report ion beam formation as a function of the expansion chamber magnetic field (0-108 G). The ion beam appears peaked in the center of the expansion chamber and decays over a few centimeters radially. We also report the potential structure of the plasma obtained with a planar Langmuir probe. To obtain meaningful Langmuir probe measurements, averages of tens of current-voltage are needed to reduce the effects of large electrostatic fluctuations that arise in plasmas that generate ion beams. We report the dependence of density, electron temperature, and floating potential on radial and axial position in the expansion plume. NSF Award PHYS-1360278.

  17. Improving Resolution of Confocal Laser Induced Fluorescence in Argon Helicon Plasma

    Science.gov (United States)

    Soderholm, Mark; Vandervort, Robert; Scime, Earl; McKee, John; McCarren, Dustin

    2014-10-01

    Laser Induced Fluorescence (LIF) provides measurements of flow speed, temperature and when absolutely calibrated, density of ions or neutrals in a plasma. Traditionally, laser induced fluorescence requires two ports on a plasma device. One port is used for laser injection and the other is used for fluorescence emission collection. Traditional LIF is tedious and time consuming to align. These difficulties motivate the development of an optical configuration that requires a single port and remains fully aligned at all times; confocal LIF. Our confocal optical design employs a single two inch diameter lens to both inject the laser light and collect the stimulated emission from an argon plasma. A dichroic mirror is used to separate the injected laser light from the collected emission. The measurement location is scanned radially by manually adjusting the final focusing lens position. In the initial version of the confocal optical system, measurements were poorly resolved radially because they were integrated over a fairly large path length (~4 cm) centered at the focal point. Here we present collected data from a modified configuration that significantly improves the special resolution of confocal measurements. The confocal measurements are compared to traditional, two-port, LIF measurements over the same radial range.

  18. Titanium surface modification by using microwave-induced argon plasma in various conditions to enhance osteoblast biocompatibility

    OpenAIRE

    Seon, Gyeung Mi; Seo, Hyok Jin; Kwon, Soon Young; Lee, Mi Hee; Kwon, Byeong-Ju; Kim, Min Sung; Koo, Min-Ah; Park, Bong Joo; Park,Jong-Chul

    2015-01-01

    Background Titanium is a well proven implantable material especially for osseointegratable implants by its biocompatibility and anti-corrosive surface properties. Surface characteristics of the implant play an important role for the evolution of bone tissue of the recipient site. Among the various surface modification methods, plasma treatment is one of the promising methods for enhance biocompatibility. We made microwave-induced argon plasma at atmospheric pressure to improve in titanium sur...

  19. Evaluation of Some Plasma Coagulation Factors in Women with Spontaneous Miscarriage

    Directory of Open Access Journals (Sweden)

    Mahsa Besharat

    2015-10-01

    Full Text Available Background: It has been reported that 15-20% of parous female have experienced at least one miscarriage, while 3% of them have experienced two miscarriages. The goal of this study was to evaluate the plasma level of coagulation factors in women with a history of spontaneous abortions. Materials and Methods: In this case-control study, 82 women with a history of two or more abortions referred to the six private gynecologic clinics in Gorgan city without any structural abnormality were recruited during 2011-2012. Plasma levels of antithrombin III (ATIII using colorimetric assay, protein C, protein S, factor V Leiden and lupus anticoagulant (LAC using coagulation method were measured. The control group was women with a history of normal delivery and no abortions. Those under anti-coagulant therapy were excluded from the study. Data were entered into the computer using the Statistical Package for the Social Sciences (SPSS, SPSS Inc., Chicago, IL, USA version 16 and analyzed by Chi-square, t test and non-parametric tests. Results: At least one abnormality was reported in 35 cases (42.7%. Among them, protein C deficiency was the most prevalent (30.5%. ATIII was abnormal in 17.1% and lupus anti-coagulant was abnormal in 8.5%. Factor V Leiden was normal in all cases and protein S deficiency was only seen in one case. Conclusion: We suggest to perform these tests in regards to the thrombophilia in cases with spontaneous abortions in order to find an early cure for this treatable disorder.

  20. Pulsed microwave-driven argon plasma jet with distinctive plume patterns resonantly excited by surface plasmon polaritons

    Science.gov (United States)

    Chen, Zhao-Quan; Yin, Zhi-Xiang; Xia, Guang-Qing; Hong, Ling-Li; Hu, Ye-Lin; Liu, Ming-Hai; Hu, Xi-Wei; A. Kudryavtsev, A.

    2015-02-01

    Atmospheric lower-power pulsed microwave argon cold plasma jets are obtained by using coaxial transmission line resonators in ambient air. The plasma jet plumes are generated at the end of a metal wire placed in the middle of the dielectric tubes. The electromagnetic model analyses and simulation results suggest that the discharges are excited resonantly by the enhanced electric field of surface plasmon polaritons. Moreover, for conquering the defect of atmospheric argon filamentation discharges excited by 2.45-GHz of continued microwave, the distinctive patterns of the plasma jet plumes can be maintained by applying different gas flow rates of argon gas, frequencies of pulsed modulator, duty cycles of pulsed microwave, peak values of input microwave power, and even by using different materials of dielectric tubes. In addition, the emission spectrum, the plume temperature, and other plasma parameters are measured, which shows that the proposed pulsed microwave plasma jets can be adjusted for plasma biomedical applications. Project supported by the National Natural Science Foundation of China (Grant Nos. 11105002 and 61170172), the Natural Science Foundation of Anhui Province, China (Grant Nos. 1408085QA16 and 1408085ME101), the China Postdoctoral Science Foundation (Grant No. 2014M551788), and the Open-end Fund of State Key Laboratory of Advanced Electromagnetic Engineering and Technology (HUST), China (Grant No. GZ1301).

  1. Characterization of Modified Tapioca Starch in Atmospheric Argon Plasma under Diverse Humidity by FTIR Spectroscopy

    Science.gov (United States)

    Deeyai, P.; Suphantharika, M.; Wongsagonsup, R.; Dangtip, S.

    2013-01-01

    Tapioca is economical crop grown in Thailand and continues to be one of the major sources of starch. Nowadays, tapioca starch has been widely used in industrial applications, however the native form of starch has limited the applications. Thus scientists try to modify the properties of starch for increasing the stability of the granules, pastes to low pH, heat, and shear during the food process. We modify the tapioca starch by plasma treatment under an argon atmosphere. The degree of modification is determined by following water content in the starch granules. The tablet samples of native starch are also prepared and compared with the plasma treated starch. Before plasma treatment, the starch tablets are stored under three different relative humilities (RH) including 11%, 68%, and 78%RH, respectively. The samples are characterized using FTIR spectroscopy associated with the degree of cross-linking. The results show that the water molecules are engulfed into the starch structure in two ways, a tight bond and a weak absorption of water molecules which is represented at two wave number of 1630 cm-1 and 3272 cm-1, respectively. The degree of cross-linking can be identified from the relative intensity of these two peaks with the C—O—H peak at 993 cm-1. The results show that the degree of cross-linking increase in the plasma treated starch. The degree of cross-linking of the treated starch with high relative humidity is less than that of the treated starch with low relative humidity.

  2. Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces:In vitro study

    Science.gov (United States)

    Annunziata, Marco; Donnarumma, Giovanna; Caputo, Pina; Nastri, Livia; Guida, Luigi

    2016-01-01

    Background Surface treatment by argon plasma is widely used as the last step of the manufacturing process of titanium implant fixtures before their sterilization by gamma rays. The possibility of using such a technology in the daily clinical practice is particularly fascinating. The aim of the present study was to assess the effects of the argon plasma treatment on different titanium implant surfaces previously exposed In vitro to bacterial contamination. Material and Methods Sterile c.p. titanium implant discs with turned (T, Sa: 0.8 µm ), sandblasted/acid-etched (SAE, Sa: 1.3 µm) and titanium plasma sprayed (TPS, Sa: 3.0µm) surface were used in this study. A strain of Aggregatibacter actinomycetemcomitans ATCC3718 was grown at 37°C under anaerobic conditions for 24 h and then transferred on six discs for each of the three surface types. After 24 hours, a half of the contaminated discs (control group) were directly used to evaluate the colony forming units (CFUs). The other half of the contaminated discs (test group) were treated in an argon plasma chamber for 12 minutes at room temperature prior to be analyzed for CFU counting. All assays were performed using triplicate samples of each material in 3 different experiments. Results When the CFU counting was carried out on control discs, a total of 1.50x106±1.4x105, 1.55x106±7.07x104 and 3.15x106±2.12x105 CFU was respectively assessed for T, SAE and TPS discs, without statistically significant differences among the three surfaces. On the contrary, any trace of bacterial contamination was assessed for titanium discs treated in the argon plasma chamber prior to be analyzed, irrespectively to the implant surface tested. Conclusions Within the limit of this study, reported data suggested that the argon plasma technology could be efficiently used to decontaminate/sterilize previously infected titanium implant surfaces. Key words:Argon plasma, titanium implant surface, Aggregatibacter actinomycetemcomitans. PMID

  3. Discharge processes and an electrical model of atmospheric pressure plasma jets in argon

    Science.gov (United States)

    Fang, Zhi; Shao, Tao; Yang, Jing; Zhang, Cheng

    2016-01-01

    In this paper, an atmospheric pressure plasma discharge in argon was generated using a needle-to-ring electrode configuration driven by a sinusoidal excitation voltage. The electric discharge processes and discharge characteristics were investigated by inspecting the voltage-current waveforms, Lissajous curves and lighting emission images. The change in discharge mode with applied voltage amplitude was studied and characterised, and three modes of corona discharge, dielectric barrier discharge (DBD) and jet discharge were identified, which appeared in turn with increasing applied voltage and can be distinguished clearly from the measured voltage-current waveforms, light-emission images and the changing gradient of discharge power with applied voltage. Based on the experimental results and discharge mechanism analysis, an equivalent electrical model and the corresponding equivalent circuit for characterising the whole discharge processes accurately was proposed, and the three discharge stages were characterised separately. A voltage-controlled current source (VCCS) associated with a resistance and a capacitance were used to represent the DBD stage, and the plasma plume and corona discharge were modelled by a variable capacitor in series with a variable resistor. Other factors that can influence the discharge, such as lead and stray capacitance values of the circuit, were also considered in the proposed model. Contribution to the Topical Issue "Recent Breakthroughs in Microplasma Science and Technology", edited by Kurt Becker, Jose Lopez, David Staack, Klaus-Dieter Weltmann and Wei Dong Zhu.

  4. Effects of metastable species in helium and argon atmospheric pressure plasma jets (APPJs) on inactivation of periodontopathogenic bacteria

    Science.gov (United States)

    Yoon, Sung-Young; Kim, Kyoung-Hwa; Seol, Yang-Jo; Kim, Su-Jeong; Bae, Byeongjun; Huh, Sung-Ryul; Kim, Gon-Ho

    2016-05-01

    The helium and argon have been widely used as discharge gases in atmospheric pressure plasma jets (APPJs) for bacteria inactivation. The APPJs show apparent different in bullet propagation speed and bacteria inactivation rate apparently vary with discharge gas species. This work shows that these two distinctive features of APPJs can be linked through one factor, the metastable energy level. The effects of helium and argon metastable species on APPJ discharge mechanism for reactive oxygen nitrogen species (RONS) generation in APPJs are investigated by experiments and numerical estimation. The discharge mechanism is investigated by using the bullet velocity from the electric field which is obtained with laser induced fluorescence (LIF) measurement. The measured electric field also applied on the estimation of RONS generation, as electron energy source term in numerical particle reaction. The estimated RONS number is verified by comparing NO and OH densities to the inactivation rate of periodontitis bacteria. The characteristic time for bacteria inactivation of the helium-APPJ was found to be 1.63 min., which is significantly less than that of the argon-APPJ, 12.1 min. In argon-APPJ, the argon metastable preserve the energy due to the lack of the Penning ionization. Thus the surface temperature increase is significantly higher than helium-APPJ case. It implies that the metastable energy plays important role in both of APPJ bullet propagation and bacteria inactivation mechanism.

  5. Exploring the electron density in plasma induced by EUV radiation: II. Numerical studies in argon and hydrogen

    CERN Document Server

    Astakhov, D I; Lee, C J; Ivanov, V V; Krivtsun, V M; Koshelev, K N; Lopaev, D V; van der Horst, R M; Beckers, J; Osorio, E A; Bijkerk, F

    2016-01-01

    We used numerical modeling to study the evolution of EUV-induced plasmas in argon and hydrogen. The results of simulations were compared to the electron densities measured by microwave cavity resonance spectroscopy. It was found that the measured electron densities can be used to derive the integral amount of plasma in the cavity. However, in some regimes, the impact of the setup geometry, EUV spectrum, and EUV induced secondary emission should be taken into account. The influence of these parameters on the generated plasma and the measured electron density is discussed.

  6. Laser light scattering in a laser-induced argon plasma: Investigations of the shock wave

    Energy Technology Data Exchange (ETDEWEB)

    Pokrzywka, B. [Obserwatorium Astronomiczne na Suhorze, Uniwersytet Pedagogiczny, ulica Podchorazych 2, 30-084 Krakow (Poland); Mendys, A., E-mail: agata.mendys@uj.edu.pl [Instytut Fizyki im. M. Smoluchowskiego, Uniwersytet Jagiellonski, ulica Reymonta 4, 30-059 Krakow (Poland); Dzierzega, K.; Grabiec, M. [Instytut Fizyki im. M. Smoluchowskiego, Uniwersytet Jagiellonski, ulica Reymonta 4, 30-059 Krakow (Poland); Pellerin, S. [GREMI, site de Bourges, Universite d' Orleans, CNRS, rue Gaston Berger BP 4043, 18028 Bourges (France)

    2012-08-15

    Shock wave produced by a laser induced spark in argon at atmospheric pressure was examined using Rayleigh and Thomson scattering. The spark was generated by focusing a laser pulse from the second harmonic ({lambda} = 532 nm) of a nanosecond Nd:YAG laser using an 80 mm focal length lens, with a fluence of 2 kJ{center_dot}cm{sup -2}. Images of the spark emission were recorded for times between 30 ns and 100 {mu}s after the laser pulse in order to characterize its spatial evolution. The position of the shock wave at several instants of its evolution and for several plasma regions was determined from the Rayleigh-scattered light of another nanosecond Nd:YAG laser (532 nm, 40 J{center_dot}cm{sup -2} fluence). Simultaneously, Thomson scattering technique was applied to determine the electron density and temperature in the hot plasma core. Attempts were made to describe the temporal evolution of the shock wave within a self-similar model, both by the simple Sedov-Taylor formula as well as its extension deduced by de Izarra. The temporal radial evolution of the shock position is similar to that obtained within theory taking into account the counter pressure of the ambient gas. Density profiles just behind the shock front are in qualitative agreement with those obtained by numerically solving the Euler equations for instantaneous explosion at a point with counter pressure. - Highlights: Black-Right-Pointing-Pointer We investigated shock wave evolution by Rayleigh scattering method. Black-Right-Pointing-Pointer 2D map of shockwave position for several times after plasma generation is presented. Black-Right-Pointing-Pointer Shock wave evolution is not satisfactorily described within self-similar models. Black-Right-Pointing-Pointer Evolution of shock position similar to theory taking into account counter pressure. Black-Right-Pointing-Pointer Density profile behind the shock similar to numerical solution of Euler equations.

  7. Effect of Argon Plasma Treatment on Tribological Properties of UHMWPE/MWCNT Nanocomposites

    Directory of Open Access Journals (Sweden)

    Nitturi Naresh Kumar

    2016-08-01

    Full Text Available Ultra-high molecular weight polyethylene (UHMWPE is widely used in artificial joints in the replacement of knee, hip and shoulder that has been impaired as a result of arthritis or other degenerative joint diseases. The UHMWPE made plastic cup is placed in the joint socket in contact with a metal or ceramic ball affixed to a metal stem. Effective reinforcement of multi-walled carbon nanotubes (MWCNTs in UHMWPE results in improved mechanical and tribological properties. The hydrophobic nature of the nanocomposites surface results in lesser contact with biological fluids during the physiological interaction. In this project, we investigate the UHMWPE/MWCNTs nanocomposites reinforced with MWCNTs at different concentrations. The samples were treated with cold argon plasma at different exposure times. The water contact angles for 60 min plasma-treated nanocomposites with 0.0, 0.5, 1.0, 1.5, and 2.0 wt % MWCNTs were found to be 55.65°, 52.51°, 48.01°, 43.72°, and 37.18° respectively. Increasing the treatment time of nanocomposites has shown transformation from a hydrophobic to a hydrophilic nature due to carboxyl groups being bonded on the surface for treated nanocomposites. Wear analysis was performed under dry, and also under biological lubrication, conditions of all treated samples. The wear factor of untreated pure UHMWPE sample was reduced by 68% and 80%, under dry and lubricated conditions, respectively, as compared to 2 wt % 60 min-treated sample. The kinetic friction co-efficient was also noted under both conditions. The hardness of nanocomposites increased with both MWCNTs loading and plasma treatment time. Similarly, the surface roughness of the nanocomposites was reduced.

  8. The study of FTO surface texturing fabrication using Argon plasma etching technique for DSSC applications

    Science.gov (United States)

    Jayanti, Lindha; Kusumandari; Sujitno, Tjipto; Suryana, Risa

    2016-02-01

    This paper is aimed to investigate the fabrication of the fluorine-doped tin oxide (FTO) texturing by using Argon (Ar) plasma etching. The pressure and temperature of Ar gas during plasma etching were 1.6 mbar and 240-285oC, respectively. The plasma etching time was varied from 3 and 10 min. We also prepared without etching samples as reference. UV-Vis spectrophotometer showed that the transmittances of etching samples are higher than the without etching samples. The root mean square roughness (Rq) of etching samples are lower than the without etching samples. It is considered that the Ar ions bombardment can modify the FTO surfaces. However, the etching time does not significantly affect the FTO surfaces for 3 min and 10 min. The Rq of the without etching sample, the etching sample for 3 min, and the etching sample for 10 min are 11.697 nm, 9.859 nm, and 9.777 nm, respectively. These results are good agreement with the four point probe measurement that indicated that the sheet resistance (RS) for each the without sample, the etching sample for 3 min, and the etching sample for 10 min are 16.817 Ωsq, 16.067 Ω/sq, and 15.990 Ω/sq. In addition, the optical transmittance of the etching sample for 3 min and the etching sample for 10 min at wavelengths of 350 - 850 nm are almost similar. This is evidence that the etching time below 10 min cannot significantly change the morphology, optical and electrical properties.

  9. An Experimental Study of the Drag Force on a Cylinder Exposed to an Argon Thermal Plasma Cross Flow

    Institute of Scientific and Technical Information of China (English)

    XinTao; XiChen; 等

    1992-01-01

    Experimental data are presented concerning the drag force on a cylinder exposed to an argon plasma cross flow with temperatures about 104 K and velocities about 102 m/s.Using a method of sweeping a cylindrical probe across an argon plasma jet,the total drag force on the cylinder can be measured as a function of the lateral distance of cylindrical probe with respect to the plasma-jet axis.Through the Abel inversion,the drag force for per unit of cylinderlength and thus the drag coefflcient of cylinder have been measured under plasma conditions and compared with the values obtained from the standard drag curve of the cylinder in an isothermal flow.Experimental results show that the measured grag forces are always less than their counterparts read from the standard drag curve with the smae Reynolds numbers based on the oncoming plasma properties.Thew drag force on the cylinder exoposed to a thermal plasma flow is shown to be approximately proportional to the square root of cylinder diameter in the present experiment and it increases slightly proportional to the square root of cylinder diameter in the present experiment and if increases slightly with increasing surface temperature of the cylinder,.It is also shown that applying a voltage between the drag prode and the anode of the plasma jet generator has little effect on the drag force of cylinder under the experimental conditions.The drag force on a cylinder with finite length exposed to an argon plasma with the axis parallel to the plams jet is independent of ration of cylinder length to its dismeter L/d for the cases when L/d≤1.

  10. Investigations on the time evolution of the plasma density in argon electron-beam plasma at intermediate pressure

    Science.gov (United States)

    Xiaoyan, BAI; Chen, CHEN; Hong, LI; Wandong, LIU

    2017-03-01

    The time evolution of the argon electron-beam plasma at intermediate pressure and low electron beam intensity was presented. By applying the amplitude modulation with the frequency of 20 Hz on the stable beam current, the plasma evolution was studied. A Faraday cup was used for the measurement of the electron beam current and a single electrostatic probe was used for the measurement of the ion current. Experimental results indicated that the ion current was in phase with the electron beam current in the pressure range from 200 Pa to 3000 Pa and in the beam current range lower than 20 mA, the residual density increased approximately linearly with the maximum density in the log-log plot and the fitting coefficient was irrelative to the pressure. And then three kinds of kinetic models were developed and the simulated results given by the kinetic model, without the consideration of the excited atoms, mostly approached to the experimental results. This indicated that the effect of the excited atoms on the plasma density can be ignored at intermediate pressure and low electron beam current intensity, which can greatly simplify the kinetic model. In the end, the decrease of the plasma density when the beam current was suddenly off was studied based on the simplified model and it was found that the decease characteristic at intermediate pressure was approximate to the one at high pressure at low electron beam intensity, which was in good accordance with the experimental results. Supported by National Natural Science Foundations of China (No. 11375187) and the Foundation of State key Laboratory of China (No. SKLIPR1510).

  11. Diagnosis of a low pressure capacitively coupled argon plasma by using a simple collisional-radiative model

    Institute of Scientific and Technical Information of China (English)

    Yu Yi-Qing; Xin Yu; Ning Zhao-Yuan

    2011-01-01

    This paper proposes a simple collisional-radiative model to characterise capacitively coupled argon plasmas driven by conventional radio frequency in combination with optical emission spectroscopy and Langmuir probe measurements.Two major processes are considered in this model, electron-impact excitation and the spontaneous radiative decay.taken into account. Behaviours of representative metastable and radiative states are discussed. Two emission lines (located at 696.5 nm and 750.4 nm) are selected and intensities are measured to obtain populated densities of the corresponding radiative states in the argon plasma. The calculated results agree well with that measured by Langmuir probe, indicating that the current model combined with optical emission spectroscopy is a candidate tool for electron density and temperature measurement in radio frequency capacitively coupled discharges.

  12. Gas temperature determination in an argon non-thermal plasma at atmospheric pressure from broadenings of atomic emission lines

    Science.gov (United States)

    Yubero, C.; Rodero, A.; Dimitrijevic, M. S.; Gamero, A.; García, M. C.

    2017-03-01

    In this work a new spectroscopic method, allowing gas temperature determination in argon non-thermal plasmas sustained at atmospheric pressure, is presented. The method is based on the measurements of selected pairs of argon atomic lines (Ar I 603.2 nm/Ar I 549.6 nm, Ar I 603.2 nm/Ar I 522.1 nm, Ar I 549.6 nm/Ar I 522.1 nm). For gas temperature determination using the proposed method, there is no need of knowing the electron density, neither making assumptions on the degree of thermodynamic equilibrium existing in the plasma. The values of the temperatures obtained using this method, have been compared with the rotational temperatures derived from the OH ro-vibrational bands, using both, the well-known Boltzmann-plot technique and the best fitting to simulated ro-vibrational bands. A very good agreement has been found.

  13. Effect of Fast Curing Lights, Argon Laser, and Plasma Arc on Bond Strengths of Orthodontic Brackets: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    M. Hashem-Hoseini

    2008-12-01

    Full Text Available Objective: Nowadays light-cured composites are used widely by orthodontists to bond brackets. As these composites require 20-40 seconds time per tooth to be light cured, more chair-time in needed compared to self-cured composites. In recent years, the argon laser and plasma arc lights have been introduced in dentistry to reduce this curing time. The purpose of this study was to compare bond strength of brackets bonded with the argon la-ser and plasma arc light with those bonded with the conventional halogen light.Materials and Methods: Fifty-one intact human premolars were randomly divided into three groups of 17 teeth each. Stainless steel twin premolar brackets (018- in Dyna lock, 3M Unitek were bonded to the teeth using one of these curing devices in each group: the halogen unit (Coltolux 75, Switzerland, the argon laser unit (Bo-5, Iran , and the plasma arc unit (Remecure 15, Belgium. The orthodontic adhesive was the same in the three groups (Transbond XT, 3M Unitek. After thermal cycling, the diametral tensilebond strength of specimens was measured using a debonding plier in a Zwick Universal Testing machine (Z/100, Germany.Results: The mean bond strengths was 17.344 MPa (SD=4.567 for halogen 19.172 MPa(SD=6.328 for laser and 19.322 MPa (SD=4.036 for plasma arc groups. No statistically significant difference existed in the mean bond strengths among three groups.Conclusion: Argon laser lights, significantly reducing the curing time of orthodonticbrackets without affecting bond strength, have the potential to be considered as advanta-geous alternatives to conventional halogen light.

  14. Analysis of tungsten carbide coatings by infrared laser-induced argon spark with inductively coupled plasma atomic emission spectrometry

    Science.gov (United States)

    Kanický, V.; Otruba, V.; Mermet, J.-M.

    2000-10-01

    Infrared laser ablation was studied for application to the analysis of plasma-sprayed tungsten carbide/cobalt coatings. The potential of the laser induced argon-spark (LINA-Spark™), as a sample introduction device in inductively coupled plasma atomic emission spectrometry was studied. The use of an IR laser along with defocusing led to laser-induced microplasma-based ablation. The mass ablation rate, represented by the ICP emission intensity per laser beam unit area, exhibited a flat increase in the irradiance range 2-250 GW/cm 2. A low slope (0.5) of this dependence in log-log scale gave evidence of plasma shielding. The steep increase in the measured acoustic signal when focused in front of the sample, i.e. in argon, indicated a breakdown of argon. Consequently, considerably lower ICP emissions were observed within the same range of irradiance. The cobalt/tungsten line intensity ratio in the ICP was practically constant from 1.5 up to at least 250 GW/cm 2. Acceptable precision (R.S.D.<5%) was obtained without internal standardization for irradiance between 2 and 8 GW/cm 2. Optimization of the laser pulse energy, repetition rate, beam focusing and sample displacement during interaction led to the linearization of dependences of signal vs. cobalt percentage, at least up to the highest studied value of 23% Co.

  15. Integrated parametric study of a hybrid-stabilized argon-water arc under subsonic, transonic and supersonic plasma flow regimes

    Science.gov (United States)

    Jeništa, J.; Takana, H.; Nishiyama, H.; Bartlová, M.; Aubrecht, V.; Křenek, P.; Hrabovský, M.; Kavka, T.; Sember, V.; Mašláni, A.

    2011-11-01

    This paper presents a numerical investigation of characteristics and processes in the worldwide unique type of thermal plasma generator with combined stabilization of arc by argon flow and water vortex, the so-called hybrid-stabilized arc. The arc has been used for spraying of ceramic or metallic particles and for pyrolysis of biomass. The net emission coefficients as well as the partial characteristics methods for radiation losses from the argon-water arc are employed. Calculations for 300-600 A with 22.5-40 standard litres per minute (slm) of argon reveal transition from a transonic plasma flow for 400 A to a supersonic one for 600 A with a maximum Mach number of 1.6 near the exit nozzle of the plasma torch. A comparison with available experimental data near the exit nozzle shows very good agreement for the radial temperature profiles. Radial velocity profiles calculated 2 mm downstream of the nozzle exit show good agreement with the profiles determined from the combination of calculation and experiment (the so-called integrated approach). A recent evaluation of the Mach number from the experimental data for 500 and 600 A confirmed the existence of the supersonic flow regime.

  16. Metastable argon atom density in complex argon/acetylene plasmas determined by means of optical absorption and emission spectroscopy

    Science.gov (United States)

    Sushkov, Vladimir; Herrendorf, Ann-Pierra; Hippler, Rainer

    2016-10-01

    Optical emission and absorption spectroscopy has been utilized to investigate the instability of acetylene-containing dusty plasmas induced by growing nano-particles. The density of Ar(1s5) metastable atoms was derived by two methods: tunable diode laser absorption spectroscopy and with the help of the branching ratio method of emitted spectral lines. Results of the two techniques agree well with each other. The density of Ar(1s3) metastable atoms was also measured by means of optical emission spectroscopy. The observed growth instability leads to pronounced temporal variations of the metastable and other excited state densities. An analysis of optical line ratios provides evidence for a depletion of free electrons during the growth cycle but no indication for electron temperature variations.

  17. Influence of argon fraction on plasma parameters in H2-N2 mixture discharge with cathodic cage

    Science.gov (United States)

    Naeem, Muhammad; Zaka-ul-Islam, Mujahid; Khattak, Zahid Iqbal; Shafiq, Muhammad; Zakaullah, Muhammad

    2017-01-01

    Low-pressure H2-N2 mixture pulsed DC plasmas with a cathodic cage (active screen) are widely used for plasma nitriding applications. In this study, the low-pressure H2-N2 mixture plasma with a cathodic cage generated by 50 Hz pulsed DC source is investigated with triple Langmuir probe and optical emission spectroscopy. The electron temperature (TeLPformula id="FI1"> math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="mml_eq1"> T e LP math> formula->) and electron number density (ne) are measured using a triple Langmuir probe (TLP). The excitation temperature (TexcOESformula id="FI2"> math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="mml_eq2"> T e xc OES math> formula->) is calculated spectroscopically using Boltzmann plot method whereas nitrogen dissociation fraction is estimated using actinometry as well as the intensity ratio method (IN (746.83 nm)/IN2(337.1 nm)). The results show that the electron and excitation temperatures, electron density and nitrogen atomic species density [N] all increase with the argon admixture, however, the important molecular ionized species density [N2+formula id="FI3"> math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="mml_eq3"> N 2 + math> formula->] significantly decreases beyond 30% addition. This study provides useful information about the influence of the argon addition on plasma parameters and active species generation. As a result it helps to optimize the plasma nitriding system as a function of argon admixture to avoid random trials in the processing.

  18. Effects of post-deposition argon implantation on the memory properties of plasma-deposited silicon nitride films

    Science.gov (United States)

    Shams, Q. A.; Brown, W. D.

    1989-10-01

    Post-deposition ion implantation has been used to introduce argon into plasma-enhanced chemically vapor deposited silicon nitride films in an attempt to influence the transfer, trapping, and emission of charge during write/erase exercising of the metal-silicon nitride-silicon oxide-silicon structure. Argon was implanted into the SiH4 -NH3 -N2 deposited films at energies ranging from 25 to 75 keV, current densities ranging from 0.1 to 75 μA/cm2 and fluences ranging from 1×1012 to 1×1016 ions/cm2. Physical properties of the films were studied by ellipsometry and infrared spectroscopy, while high frequency capacitance-voltage (C-V) curves were used to obtain programming, retention, and endurance characteristics.

  19. Sensitivity of injected argon behavior to changes in magnetic balance in double-null plasmas in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, T.W. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States)], E-mail: petrie@fusion.gat.com; Brooks, N.H. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Fenstermacher, M.E.; Groth, M. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States); Hyatt, A.W. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States); Leonard, A.W. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Porter, G.D. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States); Schaffer, M.J.; Wade, M.R. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Watkins, J.G. [Sandia National Laboratories, P.O. Box 5800, Albuquerque, NM 87185 (United States); West, W.P. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States)

    2009-06-15

    Recent DIII-D experiments show that both magnetic balance and particle drifts are important to understanding how argon impurities accumulate in balanced and unbalanced double-null plasmas during 'puff and pump' radiating divertor operation. Unbalanced double-null shapes, which are biased in the direction opposite to the ion Bx{nabla}B drift direction, have produced the best result to-date in terms of coupling a radiating divertor approach with an H-mode plasma. The proximity to balanced double-null that can be used for puff-and-pump may depend on the width of the heat flux profile in the scrape-off layer. A comparison of plasma behavior in the open lower divertor to that of the more closed upper divertor determined that plasma density control was far more sensitive to the ion Bx{nabla}B drift direction than to the relative closure of the divertor.

  20. Characterization of magnetically confined low-pressure plasmas produced by an electromagnetic field in argon-acetylene mixtures

    Science.gov (United States)

    Makdessi, G. Al; Margot, J.; Clergereaux, R.

    2016-10-01

    Dust particles formation was investigated in magnetically confined low-pressure plasma produced in argon-acetylene mixtures. The plasma characteristics were measured in order to identify the species involved in the dust particles formation. Their dependence on the operating conditions including magnetic field intensity, acetylene fraction in the gas mixture and operating pressure was examined. In contrast with noble gases, in the presence of acetylene, the electron temperature increases with the magnetic field intensity, indicating additional charged particles losses in the plasma. Indeed, in these conditions, larger hydrocarbon ions are produced leading to the formation of dust particles in the plasma volume. The observed dependence of positive ion mass distribution and density and relative negative ion density on the operating parameters suggests that the dust particles are formed through different pathways, where negative and positive ions are both involved in the nucleation.

  1. Study on structural, morphological and thermal properties of surface modified polyvinylchloride (PVC) film under air, argon and oxygen discharge plasma

    Science.gov (United States)

    Suganya, Arjunan; Shanmugavelayutham, Gurusamy; Serra Rodríguez, Carmen

    2016-09-01

    The effect of air, argon, oxygen DC glow discharge plasma on the polyvinylchloride (PVC) film synthesized by solution casting technique, were evaluated via changes in physio-chemical properties such as structural, morphological, crystalline, thermal properties. The PVC film was plasma treated as a function of exposure time and different plasma forming gases, while other operating parameters such as power and pressure remained constant at 100 W and 2 Pa respectively. The plasma treated PVC were characterized by static contact angle, ATR-FTIR, XPS, AFM and T-peel analysis. It was found that various gaseous plasma treatments have improved the polar components, surface roughness on the surface of PVC which was confirmed by XPS, AFM, resulting in highly enhanced wettability and adhesion. X-ray diffraction study showed that plasma treatment does not persuade considerable change, even though it vaguely induces the crystallinity. The thermal properties of plasma treated PVC were evaluated by Differential Scanning Calorimetry and it was observed that O2 plasma treatment gives higher glass transition temperature of 87.21 °C compared with the untreated one. The glass transition temperature slightly increased for Oxygen plasma treated material due to the presence of higher concentration of the polar functional groups on the PVC surface due to strong intramolecular bonding.

  2. The effect of different methods of leucoreduction on plasma coagulation factors.

    Science.gov (United States)

    Aboul Enein, Azza A; Abdel Rahman, Hala A; Abdel Maged, Mohamed M M; El Sissy, Maha H

    2017-03-01

    Removal of leucocytes from blood products, namely leucoreduction, improves the safety of blood transfusion by reducing adverse events associated with the incidental transfusion of leucocytes. Coagulation factors might be compromised during leucoreduction because of exposure of plasma to a variety of filter materials. The aim of the current study was to assess the effect of different methods of prestorage leucofiltration (apheresis and whole blood filters) on prothrombin time, international normalized ratio, partial thromboplastin time and factors V and VIII. There was a significant prolongation of prothrombin time as well as elevation of international normalized ratio in plasma after leucoreduction (14.5 ± 0.7 s vs. 13.9 ± 0.7 s, P = 0.008 and 1.14 ± 0.07 vs. 1.09 ± 0.07, P = 0.005, respectively). Also, there was a statistically significant prolongation of activated partial thromboplastin time in nonleucoreduced plasma (55.6 ± 9.9 s vs. 43.2 ± 12.8 s, P = 0.001). There was no significant filtration effect on factors V and VIII levels. Furthermore, there was no significant difference in factors V and VIII levels between plasma filtered by inline whole blood filters and apheresis machine. Leucodepleted plasma originating from both inline whole blood filter and apheresis machine maintained satisfactory levels of factors V and VIII.

  3. Pathogen inactivation in fresh frozen plasma using riboflavin and ultraviolet light: Effects on plasma proteins and coagulation factor VIII

    Directory of Open Access Journals (Sweden)

    Stanojković Zoran

    2011-01-01

    Full Text Available Background/Aim. Riboflavin (vitamin B2 activated by ultraviolet (UV light, produces active oxygen which damages cell membrane and prevents replication of the carrier of diseases (viruses, bacteria, protozoa in all blood products. The aim of this study was to establish the influence of the process of photo inactivation in pathogens using riboflavin and UV rays on the concentration of coagulation factor VIII:C (FVIII:C and proteins in plasma that were treated before freezing. Methods. The examination included 20 units of plasma, separated from whole blood donated by voluntary blood donors around 6 hours from the moment of collection. The units were pooled and separated in to two groups: one consisted of 10 control units and the other of 10 experimental units. Experimental units of the plasma were treated by riboflavin (35 mL and UV rays (6.24 J/mL, 265-370 nm on Mirasol aparature (Caridian BCT Biotechnologies, USA in approximate duration of 6 minutes. Furthermore, 35 mL of saline solution was added to the control plasma. One sample for examining was taken from the control plasma (KG and two residual were taken from experimental plasma after the addition of riboflavin either before (EG1 or post illumination (EG2. Results. Comparing the mean values of FVIII:C (% we noticed statistically significantly higher level in the EG1 group than in the EG2 group (65.00 ± 4.52 vs 63.20 ± 4.73; t = 4.323, p = 0.002, while between the KG and experimental groups (EG1 and EG2 there was no statistically significant difference in the concentration of FVIII:C. There was a statistically significant decrease of albumin concentration (g/L in the EG2 group comparing to the KG (33.35 ± 0.94 vs 31.94 ± 0.84; t = 3.534, p = 0.002, but there was no mentioned difference in albumin concentration between the KG and the EG1, so as between the EG1 and the EG2. Conclusion. Plasma inactivated by riboflavin and UV rays (Mirasol PRT sistem, Caridian BCT, USA keeps all the

  4. Emission spectroscopy of CW CO2 laser-sustained argon plasma - Effects of gas-flow speed

    Science.gov (United States)

    Chen, Xiangli; Mazumder, Jyotirmoy

    1989-12-01

    The effect of elevated gas-flow speed on the laser-sustained argon plasmas (LSPs) formed in laser-gas interaction was examined for the purpose of investigating the applicability of LSPs to laser-supported rocket propulsion. The electron temperature distribution, obtained from the 415.8-nm Ar line-to-continuum intensity ratio, was used to calculate the fraction of laser power absorbed by the plasma and the amount of radiation lost. Laser powers were 2.5 and 5 kW with an f/7 lens focusing scheme, and gas-flow speeds of 2-10 m/sec. It was found that as much as 86 percent of incident laser energy can be absorbed by the plasma, and 41 to 62 of the laser energy can still be retained as the gas thermal energy, which is a significant increase over the previously reported results for lower-flow speed and smaller focusing f number.

  5. Theoretical study of nanoparticle formation in thermal plasma processing: Nucleation, coagulation and aggregation

    Science.gov (United States)

    Mendoza Gonzalez, Norma Yadira

    This work presents a mathematical modeling study of the synthesis of nanoparticles in radio frequency (RF) inductively coupled plasma (ICP) reactors. The purpose is to further investigate the influence of process parameters on the final size and morphology of produced particles. The proposed model involves the calculation of flow and temperature fields of the plasma gas. Evaporation of raw particles is also accounted with the particle trajectory and temperature history calculated with a Lagrangian approach. The nanoparticle formation is considered by homogeneous nucleation and the growth is caused by condensation and Brownian coagulation. The growth of fractal aggregates is considered by introducing a power law exponent Df. Transport of nanoparticles occurs by convection, thermophoresis and Brownian diffusion. The method of moments is used to solve the particle dynamics equation. The model is validated using experimental results from plasma reactors at laboratory scale. The results are presented in the following manner. First, use is made of the computational fluid dynamics software (CFD), Fluent 6.1 with a commercial companion package specifically developped for aerosols named: Fine Particle Model (FPM). This package is used to study the relationship between the operating parameters effect and the properties of the end products at the laboratory scale. Secondly, a coupled hybrid model for the synthesis of spherical particles and fractal aggregates is developped in place of the FPM package. Results obtained from this model will allow to identify the importance of each parameter in defining the morphology of spherical primary particles and fractal aggregates of nanoparticles. The solution of the model was made using the geometries and operating conditions of existing reactors at the Centre de Recherche en Energie, Plasma et Electrochimie (CREPE) of the Universite de Sherbrooke, for which experimental results were obtained experimentally. Additionally, this study

  6. Evaluation of bone response to synthetic bone grafting material treated with argon-based atmospheric pressure plasma

    Energy Technology Data Exchange (ETDEWEB)

    Beutel, Bryan G., E-mail: bryanbeutel@gmail.com; Danna, Natalie R.; Gangolli, Riddhi; Granato, Rodrigo; Manne, Lakshmiprada; Tovar, Nick; Coelho, Paulo G.

    2014-12-01

    Bone graft materials are utilized to stimulate healing of bone defects or enhance osseointegration of implants. In order to augment these capabilities, various surface modification techniques, including atmospheric pressure plasma (APP) surface treatment, have been developed. This in vivo study sought to assess the effect of APP surface treatment on degradation and osseointegration of Synthograft™, a beta-tricalcium phosphate (β-TCP) synthetic bone graft. The experimental (APP-treated) grafts were subjected to APP treatment with argon for a period of 60 s. Physicochemical characterization was performed by environmental scanning electron microscopy, surface energy (SE), and x-ray photoelectron spectroscopy analyses both before and after APP treatment. Two APP-treated and two untreated grafts were surgically implanted into four critical-size calvarial defects in each of ten New Zealand white rabbits. The defect samples were explanted after four weeks, underwent histological analysis, and the percentages of bone, soft tissue, and remaining graft material were quantified by image thresholding. Material characterization showed no differences in particle surface morphology and that the APP-treated group presented significantly higher SE along with higher amounts of the base material chemical elements on it surface. Review of defect composition showed that APP treatment did not increase bone formation or reduce the amount of soft tissue filling the defect when compared to untreated material. Histologic cross-sections demonstrated osteoblastic cell lines, osteoid deposition, and neovascularization in both groups. Ultimately, argon-based APP treatment did not enhance the osseointegration or degradation of the β-TCP graft. Future investigations should evaluate the utility of gases other than argon to enhance osseointegration through APP treatment. - Highlights: • Degradation/osseointegration of bone graft treated with argon-based APP is studied. • APP treatment did

  7. A hybrid model of radio frequency biased inductively coupled plasma discharges: description of model and experimental validation in argon

    Science.gov (United States)

    Wen, De-Qi; Liu, Wei; Gao, Fei; Lieberman, M. A.; Wang, You-Nian

    2016-08-01

    A hybrid model, i.e. a global model coupled bidirectionally with a parallel Monte-Carlo collision (MCC) sheath model, is developed to investigate an inductively coupled discharge with a bias source. This hybrid model can self-consistently reveal the interaction between the bulk plasma and the radio frequency (rf) bias sheath. More specifically, the plasma parameters affecting characteristics of rf bias sheath (sheath length and self-bias) are calculated by a global model and the effect of the rf bias sheath on the bulk plasma is determined by the voltage drop of the rf bias sheath. Moreover, specific numbers of ions are tracked in the rf bias sheath and ultimately the ion energy distribution function (IEDF) incident on the bias electrode is obtained. To validate this model, both bulk plasma density and IEDF on the bias electrode in an argon discharge are compared with experimental measurements, and a good agreement is obtained. The advantage of this model is that it can quickly calculate the bulk plasma density and IEDF on the bias electrode, which are of practical interest in industrial plasma processing, and the model could be easily extended to serve for industrial gases.

  8. Broadening of the Spectral Atomic Lines Analysis in High Density Argon Corona Plasma by Using Voigt Profile

    Science.gov (United States)

    Nur, M.; Bonifaci, N.; Denat, A.; Atrazhev, V. M.

    2015-06-01

    Studies of spectrum emission from high density argon plasma corona has been done. The analysis of the boardening of spectral atomic lines of Ar-I profile has been curried out by using an empirical approximation based on a Voigt profile. Full-width at half-maximum (FWHM) of the spectral-lines of 763.5 nm has been determined from atmospheric pressure until liquid state. The study liquid argon was curried out in a variation of temperature from K to 151.2 K and hydrostatics pressure from 2.1 MPa to 6.4 MPa. These pressure gives the densities N∞ (i.e. density very far from ionization zone) a variation from 1.08 1022 to 2.11 1022 cm-3. FWHM of Voigt approximation (Wv) of the line 763,5 nm of 'Ar I for: the emission lamp very low pressure (Wv = 0,160 nm) and our corona discharge at a pressure of MPa (Wv = 0,67 nm) and at a pressure of 9,5 MPa (Wv = 1,16 nm). In gas, corona plasma has been generated from 0.1 MPa to 9.5 MPa. We found that the broadening spectral line increase by increasing densities both for. the spectral-lines of 763.5 nm and 696.5 nm. We concluded that broadening of spectrum cause of Van der Waals force.

  9. Determination of dissolved boron in fresh, estuarine, and geothermal waters by d.c. argon-plasma emission spectrometry

    Science.gov (United States)

    Ball, J.W.; Thompson, J.M.; Jenne, E.A.

    1978-01-01

    A d.c. argon-plasma emission spectrometer is used to determine dissolved boron in natural (fresh and estuarine) water samples. Concentrations ranged from 0.02 to 250 mg l-1. The emission-concentration function is linear from 0.02 to 1000 mg l-1. Achievement of a relative standard deviation of ??? 3% requires frequent restandardization to offset sensitivity changes. Dilution may be necessary to overcome high and variable electron density caused by differences in alkali-metal content and to avoid quenching of the plasma by high solute concentrations of sodium and other easily ionized elements. The proposed method was tested against a reference method and found to be more sensitive, equally or more precise and accurate, less subject to interferences, with a wider linear analytical range than the carmine method. Analyses of standard reference samples yielded results in all cases within one standard deviation of the means. ?? 1978.

  10. Effect of voltage shape of electrical power supply on radiation and density of a cold atmospheric argon plasma jet

    Directory of Open Access Journals (Sweden)

    F Sohbatzadeh

    2017-02-01

    Full Text Available In this work, we investigated generating argon cold plasma jet at atmospheric pressure based on dielectric barrier discharge configuration using three electrical power supplies of sinusoidal, pulsed and saw tooth high voltage shapes at 8 KHZ. At first; we describe the electronic circuit features for generating high voltage (HV wave forms including saw tooth, sinusoidal and pulsed forms. Then, we consider the effect of voltage shape on the electrical breakdown. Relative concentrations of chemical reactive species such as Oxygen, atomic Nitrogen and OH were measured using optical emission spectroscopy. Using a simple numerical model, we showed a HV with less rise time increases electron density, therefore a cold plasma jet can be produced with a minimal consumption electrical power

  11. [Changes in the blood coagulating properties of preserved blood and the native and lyophilized plasma of cattle during storage].

    Science.gov (United States)

    Khubenov, Kh D

    1984-01-01

    Studied were some of the indices characterizing the blood clotting system (thrombocytes, fibrinogen, recalcified clotting time, CA-thromboplastin time, kephalin-kaolin time, thrombin time. F II, and F V) in preserved glucose-citrate blood kept at 4 degrees C, in untreated bovine plasma kept at 20 degrees C, 4 degrees C, and -20 degrees C, and in freeze-dried bovine plasma. It was concluded that bovine blood preserved with L-12 could be used as a hemostatic agent up to the 10th day after it was obtained; untreated plasma could be used up to one month after it was obtained; and freeze-dried plasma could be used up to two months after it was obtained. Following freeze-drying the coagulation properties of the plasma remained active for more than a year, and it could also be used as a hemostatic agent.

  12. Fresh frozen plasma in the pediatric age group and in congenital coagulation factor deficiency.

    Science.gov (United States)

    Muntean, Wolfgang

    2002-10-31

    Generally, the rules of good practice in transfusion medicine apply also to the pediatric age group. However, the frequency of specific diseases that might necessitate the administration of fresh frozen plasma (FFP) differs from that in adults. Physiologic differences to the later age exist in the neonatal period and in young infants, especially with respect to the hemostatic system, that must be recognized when considering administration of FFP. The plasma levels of many procoagulant factors and important anticoagulants are lower in neonates than in other age groups. Despite these findings, healthy neonates show no easy bruising, no increased bleeding during surgery, and excellent wound healing. The same discrepancy obtains between in vitro and clinical findings with primary hemostasis in neonates. The good primary hemostasis in neonates despite poor in vitro platelet function seems to be due mainly to a very high von Willebrand factor and the presence of more high-multimeric subunits of von Willebrand factor than later in life. We must assume that these particular plasma levels of procoagulant and anticoagulant proteins are essential for the correct function of neonatal hemostasis. Evidence that the hemostatic system of neonates works best with physiologic concentrations of procoagulants and anticoagulants can also be inferred from studies where the administration of clotting factor concentrates gave poor results.Since healthy neonates and young infants have excellent hemostasis, there is absolutely no indication to 'correct' these values to adult's norms prior to invasive procedures by administering FFP. Indications for FFP, met more frequently in the pediatric age group than later in life, are exchange transfusion and extracorporeal membrane oxygenation. Indications applying equally to adults are other extracorporeal life support systems, disseminated intravascular coagulation, hepatic coagulopathy, and 'complex unclear coagulopathies'. In congenital clotting

  13. Simulations and Measurement of Electron Energy and Effective Electron Temperature of Nanosecond Pulsed Argon Plasma%Simulations and Measurement of Electron Energy and Effective Electron Temperature of Nanosecond Pulsed Argon Plasma

    Institute of Scientific and Technical Information of China (English)

    闻雪晴; 信裕; 冯春雷; 丁洪斌

    2012-01-01

    The behavior of argon plasma driven by nanosecond pulsed plasma in a low-pressure plasma reactor is investigated using a global model, and the results are compared with the experimental measurements. The time evolution of plasma density and the electron energy probability function are calculated by solving the energy balance and Boltzmann equations. During and shortly after the discharge pulse, the electron energy probability function can be represented by a bi-Maxwellian distribution, indicating two energy groups of electrons. According to the effective electron temperature calculation, we find that there are more high-energy electrons that play an important role in the excitation and ionization processes than low-energy electrons. The effective electron temperature is also measured via optical emission spectroscopy to evaluate the simulation model. In the comparison, the simulation results are found to be in agreement with the measure- ments. Furthermore, variations of the effective electron temperature are presented versus other discharge parameters, such as pulse width time, pulse rise time and gas pressure.

  14. Antibacterial Activity of Cold Atmospheric Pressure Argon Plasma against 78 Genetically Different (mecA, luk-P, agr or Capsular Polysaccharide Type) Staphylococcus aureus Strains.

    Science.gov (United States)

    Matthes, Rutger; Lührman, Anne; Holtfreter, Silva; Kolata, Julia; Radke, Dörte; Hübner, Nils-Olaf; Assadian, Ojan; Kramer, Axel

    2016-01-01

    Previous studies on the antimicrobial activity of cold atmospheric pressure argon plasma showed varying effects against mecA+ or mecA-Staphylococcus aureus strains. This observation may have important clinical and epidemiological implications. Here, the antibacterial activity of argon plasma was investigated against 78 genetically different S. aureus strains, stratified by mecA, luk-P, agr1-4, or the cell wall capsule polysaccharide types 5 and 8. kINPen09® served as the plasma source for all experiments. On agar plates, mecA+luk-P-S. aureus strains showed a decreased susceptibility against plasma compared to other S. aureus strains. This study underlines the high complexity of microbial defence against antimicrobial treatment and confirms a previously reported strain-dependent susceptibility of S. aureus to plasma treatment.

  15. Application of post-discharge region of atmospheric pressure argon and air plasma jet in the contamination control of Candida albicans biofilms

    Directory of Open Access Journals (Sweden)

    Anelise Cristina Osório Cesar Doria

    Full Text Available Introduction:Candida species are responsible for about 80% of hospital fungal infections. Non-thermal plasmas operated at atmospheric pressure are increasingly used as an alternative to existing antimicrobial strategy. This work investigates the action of post-discharge region of a non-thermal atmospheric plasma jet, generated by a gliding arc reactor, on biofilms of standard strain of Candida albicans grown on polyurethane substrate. Methods Samples were divided into three groups: (i non-treated; (ii treated with argon plasma, and (iii treated with argon plus air plasma. Subsequently to plasma treatment, counting of colony-forming units (CFU/ml and cell viability tests were performed. In addition, the surface morphology of the samples was evaluated by scanning electron microscopy (SEM and optical profilometry (OP. Results Reduction in CFU/ml of 85% and 88.1% were observed in groups ii and iii, respectively. Cell viability after treatment also showed reduction of 33% in group ii and 8% in group iii, in comparison with group i (100%. The SEM images allow observation of the effect of plasma chemistry on biofilm structure, and OP images showed a reduction of its surface roughness, which suggests a possible loss of biofilm mass. Conclusion The treatment in post-discharge region and the chemistries of plasma jet tested in this work were effective in controlling Candida albicans biofilm contamination. Finally, it was evidenced that argon plus air plasma was the most efficient to reduce cell viability.

  16. Safety of plasma-derived protein C for treating disseminated intravascular coagulation in adult patients with active cancer.

    Science.gov (United States)

    Malato, Alessandra; Saccullo, Giorgia; Coco, Lucio Lo; Caracciolo, Clementina; Raso, Simona; Santoro, Marco; Zammit, Valentina; Siragusa, Sergio

    2012-02-01

    Cancer-related disseminated intravascular coagulation (DIC) is a life-threatening condition for which no effective treatment is currently available. Protein C (PC), a modulator of coagulation as well as the inflammatory system, has been successfully tested (in its activated recombinant form [a-rPC]) in sepsis-related coagulopathy, but with an increased risk for major bleeding. Plasma-derived PC (pd-PC) is more suitable than a-rPC in patients at high risk from bleeding due to its self-limiting process. We carried out a single-arm study evaluating the role of pd-PC in adult cancer patients with overt DIC. Over a period of 3 years, we treated 19 patients with overt DIC and a PC plasma concentration <50%; all received PC concentrate (Ceprotin(®), Baxter) for 72 hr in adjusted doses to restore normal PC values (70-120%). Blood coagulation, haematological tests, and the DIC score were recorded after 12, 24, 48 hr, 7 and 10 days, while clinical outcomes (bleeding, thrombosis and mortality) were recorded up to 28 days. Within 48 hr of starting pd-PC therapy, laboratory tests as well as the DIC score improved in all patients. At 28-days follow-up, no bleeding or thrombosis was observed. This is the first study to investigate the use of pd- PC for treatment of cancer-related overt DIC.

  17. Experimental study of propagation characteristics of a pulse-modulated surface-wave argon plasma at atmospheric pressure

    Science.gov (United States)

    Chen, Chuan-Jie; Li, Shou-Zhe; Wu, Yue; Li, Zhen-Ye; Zhang, Jialiang; Wang, Yong-Xing

    2016-12-01

    An atmospheric-pressure, pulse-modulated surface wave argon plasma is investigated with respect to its propagation of the ionization front. The time-resolved photographs about the advance of the ionization front are taken using a high speed camera. The ionization front velocity and its rise time when propagating along the discharge tube are measured with respect to a series of values of input power, duty ratio, and the pulse repetition frequency. The interpretations are given on the basis of the ionization and diffusion processes. And it is also found that the reduced electric field and memory effect from previous discharge impose the influence on both the ionization front velocity and its rise time strongly.

  18. Zinc, lead and copper in human teeth measured by induced coupled argon plasma atomic emission spectroscopy (ICP-AES)

    Energy Technology Data Exchange (ETDEWEB)

    Chew, L.T.; Bradley, D.A. E-mail: D.A.Bradley@exeter.ac.uk; Mohd, Y.; Jamil, M

    2000-11-15

    Inductively Coupled Argon Plasma Atomic Emission Spectroscopy (ICP-AES) has been used to determine Pb, Zn and Cu levels in 47 exfoliated human teeth (all of which required extraction for orthodontic reasons). Lead concentrations for the group were 1.7 {mu}g (g tooth mass){sup -1} to 40.5 {mu}g (g tooth mass){sup -1}, with a median of 9.8 {mu}g (g tooth mass){sup -1}. A median lead level in excess of the group value was found for the teeth of six lorry drivers who were included in the study. A more significant enhancement was found for the seven subjects whose age was in excess of 60 years. The median values for Zn and Cu were 123.0 and 0.6 {mu}g (g tooth mass){sup -1} respectively. Present values for tooth-Zn are lower than published data for other ethnic groups.

  19. Room-temperature atomic layer deposition of ZrO{sub 2} using tetrakis(ethylmethylamino)zirconium and plasma-excited humidified argon

    Energy Technology Data Exchange (ETDEWEB)

    Kanomata, K. [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa 992-8510 (Japan); Japan Society for the Promotion of Science, 5-3-1 Kojimachi, Chiyoda-ku, Tokyo 102-0083 (Japan); Tokoro, K.; Imai, T.; Pansila, P.; Miura, M.; Ahmmad, B.; Kubota, S.; Hirahara, K. [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa 992-8510 (Japan); Hirose, F., E-mail: fhirose@yz.yamagata-u.ac.jp [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa 992-8510 (Japan)

    2016-11-30

    Highlights: • RT-ALD of ZrO{sub 2} is developed using TEMAZ and plasma-excited humidified argon. • The plasma-excited humidified argon is effective in oxidizing the TEMAZ saturated ZrO{sub 2}. • We discuss the reaction mechanism of the RT-ZrO{sub 2} ALD. - Abstract: Room-temperature atomic layer deposition (ALD) of ZrO{sub 2} is developed with tetrakis(ethylmethylamino)zirconium (TEMAZ) and a plasma-excited humidified argon. A growth per cycle of 0.17 nm/cycle at room temperature is confirmed, and the TEMAZ adsorption and its oxidization on ZrO{sub 2} are characterized by IR absorption spectroscopy with a multiple internal reflection mode. TEMAZ is saturated on a ZrO{sub 2} surface with exposures exceeding ∼2.0 × 10{sup 5} Langmuir (1 Langmuir = 1.0 × 10{sup −6} Torr s) at room temperature, and the plasma-excited humidified argon is effective in oxidizing the TEMAZ-adsorbed ZrO{sub 2} surface. The IR absorption spectroscopy suggests that Zr-OH works as an adsorption site for TEMAZ. The reaction mechanism of room-temperature ZrO{sub 2} ALD is discussed in this paper.

  20. Determining the effect of freezing on coagulation testing: comparison of results between fresh and once frozen-thawed plasma.

    Science.gov (United States)

    Gosselin, Robert C; Dwyre, Denis W

    2015-01-01

    The accuracy of the results from coagulation testing can be affected by numerous preanalytic and analytic variables including the stability of the citrated sample at room temperature. Samples not tested within 2-4 h of collection should be processed and frozen for later analysis. As limited data exist about the impact of freezing samples on coagulation testing, we sought to evaluate the effect of freezing on coagulation testing. Plasma samples into 3.2% sodium citrate tubes, centrifuged to yield platelet-poor plasma, were evaluated for prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen, D-dimer, antithrombin (AT) activity, factors V, VII, VIII, IX, lupus anticoagulant and anti-Xa measurements for both unfractionated and low-molecular-weight heparins. Samples were then frozen at -70°C for at least 1 week and testing was repeated using the same lot of material. All tests strongly correlated (R > 0.85) between fresh and frozen sample results. Using paired t test analysis, significant differences between fresh and frozen tested plasma existed for PT, APTT, factors V, VIII and AT. Significant differences existed between fresh and frozen lupus anticoagulant ratios (lupus anticoagulant screen but not lupus anticoagulant confirm), and single centrifugation process underestimated the presence of lupus anticoagulant as compared to double centrifugation processing. Freezing significantly affects the results for PT, APTT, factors V and VIII activity, and AT activity, although these differences were not considered to be clinically significant. Double centrifugation is required for accurate lupus anticoagulant testing, regardless of whether platelet-poor plasma is achieved with single centrifugation.

  1. Improvement in micro-structural and mechanical properties of zinc film by surface treatment with low temperature argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Behera, Debadhyan, E-mail: debadhyan_25@yahoo.co.in [Institute of Minerals and Materials Technology, Council of Scientific and Industrial Research, Bhubaneswar 751013 (India); Mishra, Dilip K; Pradhan, Siddhartha K; Sakthivel, Ramasamy; Mohanty, Swagatika [Institute of Minerals and Materials Technology, Council of Scientific and Industrial Research, Bhubaneswar 751013 (India)

    2011-11-15

    Nanocrystalline zinc films were deposited on gold coated borosilicate glass substrates by thermal evaporation method using zinc powders as the source material and then treated with argon plasma at various temperatures. From X-ray diffraction study, the as-deposited films are found to be metallic Zn and polycrystalline in nature. The crystalline nature improves with the increase of temperature up to 200 Degree-Sign C and decreases with the further increase of temperature to 300 Degree-Sign C. The binding energy observed for Zn 2p{sub 3/2}, and the binding energy separation between Zn 2p{sub 3/2} and Zn 2p{sub 1/2} in the X-ray photoelectron spectrum indicate that the films are metallic zinc films. Transmission electron microscopic study shows hexagonal shaped grains having size {approx}58 nm upon treatment with Ar plasma. It is clearly shown the grain growth and distinct grain boundary with the increase in temperature. The average Young's modulus (E) and hardness (H) are measured to be 84 GPa and 4.0 GPa for as-deposited film, whereas 98 GPa and 5.8 GPa for plasma treated film at 200 Degree-Sign C. The enhancement in mechanical properties is attributed to improvement in crystalline nature of the film and better interlinking between grains and boundaries.

  2. Studies on Excitation and Rotational Temperatures of an Oxygen-shielded Argon Microwave Plasma Torch Source

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Excitation( Texc ) and rotation( Trot ) temperatures were determined under different conditions for an oxygen-shielded argon microwave plasmsa torch source(OS-Ar-MPT). The Texc value, which was shown to be between 4300 and 5250 K under different operating conditions, was calculated from the slope of the Boltzmann plot with Fe as the thermometric species. The Trot value, which was in the range of 2100-2500 K, was measured with OH molecular spectra. The influences of microwave power, flow rates of the support gas, carrier gas, and shielding gas, as well as the observation height on Texc and Trot were investigated and discussed. The detailed results of Texc and Trot provided a better understanding of the performance of an OS-ArMPT as a source for atomic emission spectrometry.

  3. Modification of acidity of Mo-Fe/HZSM-5 zeolite via argon plasma treatment

    Institute of Scientific and Technical Information of China (English)

    Xinli ZHU; Kailu YU; Dangguo CHENG; Yueping ZHANG; Qing XIA; Changjun LIU

    2008-01-01

    The NH3-TPD characterization was conducted to confirm that the acidity of Mo-Fe/HZSM-5 zeolite could be selectively modified via the glow discharge plasma treatment. The plasma catalyst treatment could totally change the distribution of aromatic products with higher methane conversion compared to the untreated catalyst. Some polycyclic aromatics such as anthracene, pyrene and phenanthrene were also produced over the plasma treated catalyst, in addition to benzene, toluene and naphthalene, which were normally obtained over the untreated catalyst.

  4. Electron properties and air mixing in radio frequency driven argon plasma jets at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Gessel, Bram van; Bruggeman, Peter [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Brandenburg, Ronny [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany)

    2013-08-05

    A time modulated radio frequency (RF) plasma jet operated with an Ar mixture is investigated by measuring the electron density and electron temperature using Thomson scattering. The measurements have been performed spatially resolved for two different electrode configurations and as a function of the plasma dissipated power and air concentration admixed to the Ar. Time resolved measurements of electron densities and temperatures during the RF cycle and after plasma power switch-off are presented. Furthermore, the influence of the plasma on the air entrainment into the effluent is studied using Raman scattering.

  5. COMBINED PLASMA FILTRATION, SELECTIVE ADSORPTION OF CYTOKINES WITH HEMOFILTRATION AND PLASMA EXCHANGE IN THE CORRECTION OF PLATELET AND COAGULATION HEMOSTASIS IN PATIENTS WITH THE SYNDROME OF DISSEMINATED INTRAVASCULAR COAGULATION

    Directory of Open Access Journals (Sweden)

    L. V. Belskikh

    2015-01-01

    Full Text Available Aim. To improve the efficiency of treatment of the patients with pancreatic necrosis through correcting the platelet-coagulation potential by methods of combined plasma filtration, selective sorption of cytokines with hemofiltration and plasmapheresis. Methods. The effects of selective sorption of cytokines with hemofiltration and plasmapheresis upon coagulation potential were studied in 70 patients with acute pancreatitis. Plasmapheresis was performed on PCS 2 (Haemonetics, USA; selective sorption of cytokines with hemofiltration – on Lynda ® machine (Bellco, Italy. The method of computer laser phasemeter was used for vital assessing of platelet morphofunctional status. Results. In patients with pancreatic necrosis in the fermentation phase the percentage of resting platelets was 51.3%, which is 12% below the control numbers. The number of activated platelets increased: 25.1% of the cells were represented by platelets with low activation; 15.5% – highly activated cells. The number of degenerative-modified platelets increased by two times – up to 8.1%. In the phase of sequestration and suppurative complications the percentage of resting platelets was only 42.3%, which is 1.5 times lower than the control numbers. 34.2% of the cells were presented by platelets with low activation; 11.0% – highly activated cells. The number of degenerative-modified platelets exceeded 12.5%. The analysis of the morphological structure of the platelets population revealed that due to plasmapheresis inclusion into therapeutic complex in the phase of intoxication of pancreatic necrosis the normalization of platelet activation status of hemostasis was observed. In 5 (20% patients the normalization of average platelets morphometric parameters was shown after selective sorption of cytokines with hemofiltration and plasmapheresis. These patients demonstrated positive clinical dynamics. In 15 patients morphometric values of platelets either remained at the same

  6. Measurement of plasma-surface energy fluxes in an argon rf-discharge by means of calorimetric probes and fluorescent microparticles

    Science.gov (United States)

    Maurer, H. R.; Hannemann, M.; Basner, R.; Kersten, H.

    2010-11-01

    Measured energy influx densities toward a tungsten dummy substrate in an argon rf-plasma are presented and a model for the description of the energy influx density based on plasma parameters, which have been obtained by Langmuir probe measurements, is applied. Furthermore, temperature measurements of microparticles are presented, which are confined in the plasma sheath. An extension of the model is developed for the description of the energy influx density to the particles. The comparison of model and experimental results offer the possibility to obtain an improved understanding of plasma-surface interactions.

  7. Reactivity of water vapor in an atmospheric argon flowing post-discharge plasma torch

    CERN Document Server

    Collette, S; Reniers, F

    2016-01-01

    The reactivity of water vapor introduced in the flowing post-discharge of an RF atmospheric plasma torch is investigated through electrical characterization, optical emission spectroscopy and mass spectrometry measurements. Due to the technical features of the plasma torch, the post-discharge can be considered as divided into two regions: an inner region (inside the plasma torch device) where the water vapor is injected and an outer region which directly interacts with the ambient air. The main reactions induced by the injection of water vapor are identified as well as those indicative of the influence of the ambient air. Plausible pathways allowing the production of H, OH, O radicals and H2O2 are discussed as well as reactions potentially responsible for inhomogeneities and for a low DC current measured in the flowing post-discharge. Keywords: atmospheric post-discharge, H2O plasma reactivity, RF plasma torch

  8. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.

    Science.gov (United States)

    Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan

    2017-05-15

    Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1μl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R(2)=0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring.

  9. Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

    Science.gov (United States)

    Cristofolini, Andrea; Neretti, Gabriele; Borghi, Carlo A.

    2012-08-01

    This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of Hα and the Hβ lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

  10. Effects of argon plasma treatment on the interfacial adhesion of PBO fiber/bismaleimide composite and aging behaviors

    Science.gov (United States)

    Liu, Dong; Chen, Ping; Chen, Mingxin; Yu, Qi; Lu, Chun

    2011-09-01

    This paper is concerned with the influence of argon plasma on the interfacial adhesion of PBO fiber/bismaleimide composites and aging behaviors. The interlaminar shear strength (ILSS) was greatly increased to 62.3 MPa with an increase of 39.7% after treatment for 7 min at 80 Pa, 200 W. A small amount of O and N atoms was incorporated onto the fiber surface, but the plasma caused C-O bonds to break and generated Odbnd C-N groups. The fiber surface roughness increased, contributing much to the wettability. However, long-time treatment excessively destroyed the inherent and newly created structures. The SEM images suggested that the fracture shifted from the interface to the matrix. The modification effects degraded with storage time in the air and the ILSS decreased to approximately 54.0 MPa after 10-30 days. The composite had low water absorption of 2.0 wt% and a high retention of 90% in the ILSS at moisture conditions.

  11. Excitation temperature and electron number density distributions experienced by analyte species in an inductively coupled argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kalnicky, D.J.

    1977-02-01

    Spatially resolved, radial excitation temperatures and radial electron number density distributions experienced by analyte species in the observation zone of 15 to 25 mm above the load coil of a toroidally shaped, inductively coupled argon plasma (ICP) are presented and related to the analytical performance of these plasmas. A comparison of radial temperatures measured with support gas (Ar I) lines and with a typical analyte thermometric species (Fe I) at 15 mm above the load coil is given. Radial (Fe I) excitation temperatures obtained at three observation heights (15, 20, and 25 mm) are compared for aerosol carrier gas flows of 1.0 l/min and 1.3 l/min. The addition of a large amount of an easily ionized element (6900 ..mu..g Na/ml) did not significantly change Fe I excitation temperature distributions at the respective aerosol carrier gas flows and observation heights. A comparison of radial electron number density distributions measured by the Saha-Eggert ionization and Stark broadening methods is given for an observation height of 15 mm above the load coil. The differences between the electron number density values obtained by these methods is discussed. The effect of addition of 6900 ..mu..g Na/ml on Saha-Eggert electron density distributions at these observation heights is also discussed. The computer programs employed in this investigation and discussions of the computational procedures incorporated in these programs are given.

  12. Local thermodynamic equilibrium modeling of ionization of impurities in argon inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Serapinas, Petras, E-mail: serapinas@pfi.l [Institute of Theoretical Physics and Astronomy, Vilnius University, A. Gostauto 12, 01108 Vilnius (Lithuania); Salkauskas, Julius; Ezerinskis, Zilvinas; Acus, Arturas [Institute of Theoretical Physics and Astronomy, Vilnius University, A. Gostauto 12, 01108 Vilnius (Lithuania)

    2010-01-15

    Essentially higher ionization degree of small concentrations of elements in inductively coupled plasma in comparison to the ionization of pure elements is emphasized. This conclusion is used to determine the relative dependence of the sensitivity of the inductively coupled plasma mass spectrometer on the atomic mass. The possibility of evaluation of the ionization temperature and electron density from mass spectrometric signals is proposed. Temperatures about 7000 K and 8000 K were obtained from the ionization ratio dependences on ionization potentials. Electron densities of the order of magnitude 10{sup 15} cm{sup -3}, in excess to the local thermodynamic equilibrium values, follow from the application of the Saha equation to the measurement results and indicate the recombining character of the plasma in the mass spectrometer measurement region. Effects due to additional ionization from matrix were discussed. The effect is largest on minor abundant ionization state components. Matrix effect is restricted to some temperature interval, which depends on the whole matrix composition and the plasma state. The results show that the local thermodynamic equilibrium modeling, if adequately matching the sample composition, can be useful as a quantitative basis for both description of the plasma state and indication of the character of the nonequilibrium effects.

  13. Equations of state, transport properties, and compositions of argon plasma: combination of self-consistent fluid variation theory and linear response theory.

    Science.gov (United States)

    Quan, W L; Chen, Q F; Fu, Z J; Sun, X W; Zheng, J; Gu, Y J

    2015-02-01

    A consistent theoretical model that can be applied in a wide range of densities and temperatures is necessary for understanding the variation of a material's properties during compression and heating. Taking argon as an example, we show that the combination of self-consistent fluid variational theory and linear response theory is a promising route for studying warm dense matter. Following this route, the compositions, equations of state, and transport properties of argon plasma are calculated in a wide range of densities (0.001-20 g/cm(3)) and temperatures (5-100 kK). The obtained equations of state and electrical conductivities are found in good agreement with available experimental data. The plasma phase transition of argon is observed at temperatures below 30 kK and density about 2-6g/cm(3). The minimum density for the metallization of argon is found to be about 5.8 g/cm(3), occurring at 30-40 kK. The effects of many-particle correlations and dynamic screening on the electrical conductivity are also discussed through the effective potentials.

  14. Broadband microwave characteristics of a novel coaxial gridded hollow cathode argon plasma

    Science.gov (United States)

    Gao, Ruilin; Yuan, Chengxun; Li, Hui; Jia, Jieshu; Zhou, Zhong-Xiang; Wang, Ying; Wang, Xiaoou; Wu, Jian

    2016-08-01

    The interaction between microwave and large area plasma is crucially important for space communication. Gas pressure, input power, and plasma volume are critical to both the microwave electromagnetic wave phase shift and electron density. This paper presents a novel type of large coaxial gridded hollow cathode plasma having a 50 cm diameter and a 40 cm thickness. Microwave characteristics are studied using a microwave measurement system that includes two broadband antennae in the range from 2 GHz to 18 GHz. The phase shift under varying gas pressure and input power is shown. In addition, the electron density ne, which varies from 1.2 × 1016 m-3 to 8.7 × 1016 m-3 under different discharge conditions, is diagnosed by the microwave system. The measured results accord well with those acquired by Langmuir Probe measurement and show that the microwave properties in the large volume hollow cathode discharge significantly depend on the input power and gas pressure.

  15. Argon/Hexamethyldisiloxane Plasma Effects on Poly Propylene Film Surface Properties

    Science.gov (United States)

    Mortazavi, S. H.; Ghoranneviss, M.; Sari, A. H.

    2010-10-01

    In this work a DC plasma reactor was used for deposition of plasma polymerized coating from hexamethyldisiloxane-Ar (35/65%) mixture on polypropylene films. Surface energy parameter have been calculated using Owens-Wendt approaches with the sessile drop method are used to obtain the dispersive γD and polar γP component of surface free energy. The surface morphology of samples were investigated using scanning electron microscope. Also the chemical properties and wetability of prepared samples were tested using Fourier transform infrared spectroscopy and contact angle measurement, respectively.

  16. Carbon monoxide-releasing molecule-2 enhances coagulation in rabbit plasma and decreases bleeding time in clopidogrel/aspirin-treated rabbits.

    Science.gov (United States)

    Nielsen, Vance G; Chawla, Nikhil; Mangla, Dipty; Gomes, Sheldon B; Arkebauer, Matthew R; Wasko, Kimberly A; Sadacharam, Kesavan; Vosseller, Keith

    2011-12-01

    Administration of carbon monoxide derived from carbon monoxide-releasing molecules has been demonstrated to enhance coagulation in vitro at small concentrations (100-200 μmol/l) in human and rabbit plasma. We sought to determine if carbon monoxide-releasing molecule-2 [tricarbonyldichlororuthenium (II) dimer, CORM-2] would improve coagulation in rabbit plasma in vitro via thrombelastography and in an in vivo preclinical rabbit model of ear bleeding time following administration of clopidogrel (20 mg/kg) with aspirin (10 mg/kg) via gavage. Addition of 100 μmol/l CORM-2 to rabbit plasma significantly improved coagulation. This procoagulant effect was blocked by pre-exposure of plasma to an agent that converts hemefibrinogen to methemefibrinogen in human plasma, preventing carbon monoxide binding and enhancement of coagulation. Rabbit ear bleeding time was 5.8 ± 1.1 min 2-3 h after clopidogrel/aspirin administration. Bleeding time significantly decreased to 2.6 ± 0.6 min, 5 min after administration of CORM-2 (10 mg/kg; 279 μmol/l 'best-case' instantaneous concentration) intravenously. CORM-2 enhances plasmatic coagulation in a manner similar to that of human plasma in vitro, and plasmatic coagulation is enhanced in vivo by CORM-2 as well. Additional preclinical investigation of the effects of CORM-2 on coagulopathy (e.g. heparin or hemodilution mediated) utilizing this rabbit model is planned.

  17. Growth-inducing effects of argon plasma on soybean sprouts via the regulation of demethylation levels of energy metabolism-related genes

    Science.gov (United States)

    Zhang, Jiao Jiao; Jo, Jin Oh; Huynh, Do Luong; Mongre, Raj Kumar; Ghosh, Mrinmoy; Singh, Amit Kumar; Lee, Sang Baek; Mok, Young Sun; Hyuk, Park; Jeong, Dong Kee

    2017-02-01

    This study was conducted to determine the effects of argon plasma on the growth of soybean [Glycine max (L.) Merr.] sprouts and investigate the regulation mechanism of energy metabolism. The germination and growth characteristics were modified by argon plasma at different potentials and exposure durations. Upon investigation, plasma treatment at 22.1 kV for 12 s maximized the germination and seedling growth of soybean, increasing the concentrations of soluble protein, antioxidant enzymes, and adenosine triphosphate (ATP) as well as up-regulating ATP a1, ATP a2, ATP b1, ATP b2, ATP b3, target of rapamycin (TOR), growth-regulating factor (GRF) 1–6, down-regulating ATP MI25 mRNA expression, and increasing the demethylation levels of the sequenced region of ATP a1, ATP b1, TOR, GRF 5, and GRF 6 of 6-day-old soybean sprouts. These observations indicate that argon plasma promotes soybean seed germination and sprout growth by regulating the demethylation levels of ATP, TOR, and GRF.

  18. Comparison of glow argon plasma-induced surface changes of thermoplastic polymers

    Science.gov (United States)

    Řezníčková, A.; Kolská, Z.; Hnatowicz, V.; Stopka, P.; Švorčík, V.

    2011-01-01

    Modification of high-density polyethylene (PE), polytetrafluoroethylene (PTFE), polystyrene (PS), polyethyleneterephthalate (PET) and polypropylene (PP) by Ar plasma was studied. The amount of the ablated material was determined by gravimetry. Wettability of polymers after the plasma treatment was determined from the contact angle measurement. The changes in the surface morphology of polymers were observed using atomic force microscopy (AFM). Chemical structure of modified polymers was characterized by X-ray photoelectron spectroscopy (XPS) and electron paramagnetic resonance (EPR). Surface changes were also studied by the determination of electrokinetic potential ( ζ-potential). It was found that under the plasma treatment the polymers are ablated and their surface morphology and roughness are changed dramatically. XPS measurements indicate an oxidation of the polymer surface. The plasma treatment results in a dramatic increase of the ζ-potential. EPR data show different radical amount present on the treated surface of all polymers. Most significant changes due to the degradation of polymer chains are observed on PTFE.

  19. Analysis of coagulation tests, proteins C and S, and plasma fibrinogen in addicts and non-addicts with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Abdolrasoul Moloudi

    2014-03-01

    Full Text Available Given the high incidence of drug addiction in the society and high prevalence of Coronary Artery Disease (CAD in opium users, this study was conducted to evaluate the coagulation tests and plasma levels of proteins C and S, and fibrinogen in opium users with Coronary Artery Disease (CAD. The results indicated that the plasma level of fibrinogen in addicted patients was higher than that of non-addicted patients (p=0.001, but the findings of coagulation tests and proteins C and S levels revealed no significant difference between groups.

  20. Room-temperature atomic layer deposition of ZrO2 using tetrakis(ethylmethylamino)zirconium and plasma-excited humidified argon

    Science.gov (United States)

    Kanomata, K.; Tokoro, K.; Imai, T.; Pansila, P.; Miura, M.; Ahmmad, B.; Kubota, S.; Hirahara, K.; Hirose, F.

    2016-11-01

    Room-temperature atomic layer deposition (ALD) of ZrO2 is developed with tetrakis(ethylmethylamino)zirconium (TEMAZ) and a plasma-excited humidified argon. A growth per cycle of 0.17 nm/cycle at room temperature is confirmed, and the TEMAZ adsorption and its oxidization on ZrO2 are characterized by IR absorption spectroscopy with a multiple internal reflection mode. TEMAZ is saturated on a ZrO2 surface with exposures exceeding ∼2.0 × 105 Langmuir (1 Langmuir = 1.0 × 10-6 Torr s) at room temperature, and the plasma-excited humidified argon is effective in oxidizing the TEMAZ-adsorbed ZrO2 surface. The IR absorption spectroscopy suggests that Zr-OH works as an adsorption site for TEMAZ. The reaction mechanism of room-temperature ZrO2 ALD is discussed in this paper.

  1. Modification of argon impurity transport by electron cyclotron heating in KSTAR H-mode plasmas

    Science.gov (United States)

    Hong, Joohwan; Henderson, S. S.; Kim, Kimin; Seon, C. R.; Song, Inwoo; Lee, H. Y.; Jang, Juhyeok; Park, Jae Sun; Lee, S. G.; Lee, J. H.; Lee, Seung Hun; Hong, Suk-Ho; Choe, Wonho

    2017-03-01

    Experiments with a small amount of Ar gas injection as a trace impurity were conducted in the Korea Superconducting Tokamak Advanced Research (KSTAR) H-mode plasma ({{B}\\text{T}}   =  2.8 T, {{I}\\text{P}}   =  0.6 MA, and {{P}\\text{NBI}}   =  4.0 MW). 170 GHz electron cyclotron resonance heating (ECH) at 600 and 800 kW was focused along the mid-plane with a fixed major radial position of R   =  1.66 m. The emissivity of the Ar16+ (3.949 {\\mathring{\\text{A}}} ) and Ar15+ (353.860 {\\mathring{\\text{A}}} ) spectral lines were measured by x-ray imaging crystal spectroscopy (XICS) and a vacuum UV (VUV) spectrometer, respectively. ECH reduces the peak Ar15+ emission and increases the Ar16+ emission, an effect largest with 800 kW. The ADAS-SANCO impurity transport code was used to evaluate the Ar transport coefficients. It was found that the inward convective velocity found in the plasma core without ECH was decreased with ECH, while diffusion remained approximately constant resulting in a less-peaked Ar density profile. Theoretical results from the NEO code suggest that neoclassical transport is not responsible for the change in transport, while the microstability analysis using GKW predicts a dominant ITG mode during both ECH and non-ECH plasmas.

  2. Cross-diagnostic comparison of fluctuation measurements in a cylindrical argon plasma

    Science.gov (United States)

    Light, Adam; Chakraborty Thakur, Saikat; Tynan, George

    2016-10-01

    The advent of fast imaging diagnostics, which provide two-dimensional measurements on relevant plasma time scales, has proven invaluable for interpreting plasma dynamics in laboratory devices. Despite its success, imaging remains a qualitative aid for many studies, because intensity is difficult to map onto a single physical variable for use in a theoretical model. This work continues our exploration of the relationship between visible-light imaging and other diagnostics in the Controlled Shear Decorrelation Experiment (CSDX). CSDX is a well-characterized linear machine producing dense plasmas relevant to the tokamak edge (Te 5 eV, ne 1013 /cc). Visible light from ArI and ArII line emission is collected at high frame rates using a fast digital camera, floating potential and ion-saturation current are measured by an array of electrostatic probe tips, and average profiles of ion temperature and velocity are obtained using laser-induced fluorescence (LIF). We present a detailed comparison between these measurements, including temporal, spatial, and spectral properties in various operational regimes.

  3. Etching of Niobium in an Argon-Chlorine Capacitively Coupled Plasma

    Science.gov (United States)

    Radovanov, Svetlana; Samolov, Ana; Upadhyay, Janardan; Peshl, Jeremy; Popovic, Svetozar; Vuskovic, Leposava; Applied Materials, Varian Semiconductor Team; Old Dominion University Team

    2016-09-01

    Ion assisted etching of the inner surfaces of Nb superconducting radio frequency (SRF) cavities requires control of incident ion energies and fluxes to achieve the desired etch rate and smooth surfaces. In this paper, we combine numerical simulation and experiment to investigate Ar /Cl2 capacitively coupled plasma (CCP) in cylindrical reactor geometry. Plasma simulations were done in the CRTRS 2D/3D code that self-consistently solves for CCP power deposition and electrostatic potential. The experimental results are used in combination with simulation predictions to understand the dependence of plasma parameters on the operating conditions. Using the model we were able to determine the ion current and flux at the Nb substrate. Our simulations indicate the relative importance of the current voltage phase shift and displacement current at different pressures and powers. For simulation and the experiment we have used a test structure with a pillbox cavity filled with niobium ring-type samples. The etch rate of these samples was measured. The probe measurements were combined with optical emission spectroscopy in pure Ar for validation of the model. The authors acknowledge Dr Shahid Rauf for developing the CRTRS code. Support DE-SC0014397.

  4. Compression between ion and hard x-ray emissions from nitrogen and argon in Mather type plasma focus device

    Directory of Open Access Journals (Sweden)

    S Paghe

    2016-12-01

    Full Text Available In this study, some characteristics of a Mather type Plasma Focus (PF device such as a discharge current, pinch time, ion flux and hard x-ray intensity has been investigated simultaneously in argon and nitrogen gases separately for various operating gas pressures and charging voltages of capacitor bank. It was observed that pinch phenomena was energy and pressure dependent in current sheath as well as ion and hard x-ray emission intensity. Optimum pressure with maximum ion flux and the most intense hard x-ray showed a nearly linear dependence on the charging voltage of the device. Maximum ion flux was estimated in the order of 1018 ions per steradian in both gases. Hard x-ray emission was registered a little after discharge current and Faraday cup (FC signals. Also, optimum pressure for maximum ion flux was not the same as the pressure for intense hard x-rays. Hard x-ray intensity reached its peak at higher pressures

  5. Effects of argon laser on in vitro aggregation of platelets in platelet rich plasma and whole blood

    Energy Technology Data Exchange (ETDEWEB)

    Doerger, P.T.; Glueck, H.I.; McGill, M.

    1988-06-01

    The effects of an Argon laser on platelet aggregation were studied, since platelets may be exposed to laser energy when used intravascularly. Various preparations of platelets in platelet rich plasma (PRP) and whole blood, with or without aspirin, were tested with the aggregating agents ADP, collagen, thrombin, and epinephrine. Simultaneous release of ATP was also measured in PRP. At relatively low levels of irradiation, platelet aggregation was potentiated. Enhancement was evidenced by an increase in percent aggregation, earlier onset of the reaction, and reduction in the amount of aggregating agent required. In PRP, the mechanism of laser potentiation appeared to be the release of endogenous ATP from platelets. At relatively high levels of irradiation, platelets were destroyed and aggregation abolished. In whole blood, the mechanism was somewhat more complicated since release of ATP occurred from RBCs as well as platelets. Spontaneous aggregation following laser treatment occurred in isolated instances in PRP and in every trial in whole blood preparations. Aspirin ingestion inhibited the laser's effects in PRP but not in whole blood. These results may have important clinical implications for laser angioplasty, and the potentiated aggregation response may prove useful in laboratory studies of platelet function.

  6. Electron Density and Temperature Measurement by Stark Broadening in a Cold Argon Arc-Plasma Jet at Atmospheric Pressure

    Institute of Scientific and Technical Information of China (English)

    ZHOU Qiuping; CHENG Cheng; MENG Yuedong

    2009-01-01

    Determination of both the electron density and temperature simultaneously in a cold argon arc-plasma jet by analyzing the Stark broadening of two different emission lines is presented.This method is based on the fact that the Stark broadening of different lines has a different dependence on the electron density and temperature.Therefore,a comparison of two or more line broadenings allows us to diagnose the electron density and temperature simultaneously.In this study we used the first two Balmer series hydrogen lines H_α and H_β for their large broadening width.For this purpose,a small amount of hydrogen was introduced into the discharge gas.The results of the Gigosos-Cardenoso computational model,considering more relevant processes for the hydrogen Balmer lines,is used to process the experimental data.With this method,we obtained reliable electron density and temperature,1.88 ×10 ~(15) cm~(-3 )and 13000 K,respectively.Possible sources of error were also analyzed.

  7. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with argon

    Energy Technology Data Exchange (ETDEWEB)

    Malinina, A. A., E-mail: alexandr-malinin@rambler.ru; Malinin, A. N. [Uzhhorod National University (Ukraine)

    2015-03-15

    Results are presented from studies of the optical characteristics and parameters of the plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with argon—the working medium of an exciplex gas-discharge emitter. It is established that the partial pressures of mercury dibromide vapor and argon at which the average and pulsed emission intensities in the blue—green spectral region (λ{sub max} = 502 nm) reach their maximum values are 0.6 and 114.4 kPa, respectively. The electron energy distribution function, the transport characteristics, the specific power spent on the processes involving electrons, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering from the molecules and atoms of the working mixture are determined by numerical simulation, and their dependences on the reduced electric field strength are analyzed. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules for a reduced electric field of E/N = 20 Td, at which the maximum emission intensity in the blue—green spectral region was observed in this experiment, is found to be 8.1 × 10{sup −15} m{sup 3}/s.

  8. Effects of the electrical excitation signal parameters on the geometry of an argon-based non-thermal atmospheric pressure plasma jet.

    Science.gov (United States)

    Benabbas, Mohamed Tahar; Sahli, Salah; Benhamouda, Abdallah; Rebiai, Saida

    2014-12-01

    A non-thermal atmospheric pressure argon plasma jet for medical applications has been generated using a high-voltage pulse generator and a homemade dielectric barrier discharge (DBD) reactor with a cylindrical configuration. A plasma jet of about 6 cm of length has been created in argon gas at atmospheric pressure with an applied peak to peak voltage and a frequency of 10 kV and 50 kHz, respectively. The length and the shape of the created plasma jet were found to be strongly dependent on the electrode setup and the applied voltage and the signal frequency values. The length of the plasma jet increases when the applied voltage and/or its frequency increase, while the diameter at its end is significantly reduced when the applied signal frequency increases. For an applied voltage of 10 kV, the plasma jet diameter decreases from near 5 mm for a frequency of 10 kHz to less than 1 mm at a frequency of 50 kHz. This obtained size of the plasma jet diameter is very useful when the medical treatment must be processed in a reduced space. PACS 2008: 52.50.Dg; 52.70.-m; 52.80.-s.

  9. Argon/UF6 plasma experiments: UF6 regeneration and product analysis

    Science.gov (United States)

    Roman, W. C.

    1980-03-01

    An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

  10. Numerical study of the effect of gas temperature on the time for onset of particle nucleation in argon-silane low-pressure plasmas

    CERN Document Server

    Bhandarkar, U; Girshick, S L

    2003-01-01

    Particle nucleation in silane plasmas has attracted interest for the past decade, both due to the basic problems of plasma chemistry involved and the importance of silane plasmas for many applications. A better understanding of particle nucleation may facilitate the avoidance of undesirable particle contamination as well as enable the controlled production of nanoparticles for novel applications. While understanding of particle nucleation has significantly advanced over the past years, a number of questions have not been resolved. Among these is the delay of particle nucleation with an increasing gas temperature, which has been observed in experiments in argon-silane plasmas. We have developed a quasi-one-dimensional model to simulate particle nucleation and growth in silane containing plasmas. In this paper we present a comparative study of the various effects that have been proposed as explanations for the nucleation delay. Our results suggest that the temperature dependence of the Brownian diffusion coeffi...

  11. Plasma diagnostics of the SIMPA Ecr ion source by X-ray spectroscopy, Collisions of H-like Neon ions with Argon clusters; Diagnostic du plasma de la source d'ions ECR SIMPA par spectroscopie X, Collision d'ions neon hydrogenoides avec des agregats d'argon

    Energy Technology Data Exchange (ETDEWEB)

    Adrouche, N

    2006-09-15

    The first part of this thesis is devoted to the SIMPA ECR ion source characterization, first, I explored the ion source's capacities on the point of view of extracted currents for three elements, argon, krypton and neon. By analyzing the Bremsstrahlung spectra, I determined the electronic temperature in the plasma and the electronic and ionic densities. In a second time, I recorded high resolution X-spectra of argon and krypton plasma's. By taking into account the principal mechanisms of production of a K hole in the ions inside the plasma, I determined the ionic densities of the high charge states of argon. Lastly, I highlighted a correlation between the ions charge states densities with the intensities of extracted currents. The second part of the thesis is devoted to Ne{sup 9+-} argon clusters collisions. First, I presented simple and effective theoretical models allowing to describe the phenomena occurring during a collision, from the point of view of the projectile. I carried out a simulation for a collision of an ion Ne{sup 9+} with an argon cluster of a given size, which has enabled us to know the energy levels populated during the electronic capture and to follow the number of electrons in each projectile shell. Lastly, I presented the first results of a collision between a Ne{sup 9+} beam and argon clusters. These results, have enabled me by using projectile X-ray spectroscopy during the ions-clusters collision, to evidence a strong clustering of targets atoms and to highlight an electronic multi-capture in the projectile ion excited states. (author)

  12. Comparative study on contribution of charge-transfer collision to excitations of iron ion between argon radio-frequency inductively-coupled plasma and nitrogen microwave induced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Kozue; Wagatsuma, Kazuaki, E-mail: wagatuma@imr.tohoku.ac.jp

    2015-06-01

    This paper describes an ionization/excitation phenomenon of singly-ionized iron occurring in an Okamoto-cavity microwave induced plasma (MIP) as well as an argon radio-frequency inductively-coupled plasma (ICP), by comparing the Boltzmann distribution among iron ionic lines (Fe II) having a wide range of the excitation energy from 4.76 to 9.01 eV. It indicated in both the plasmas that plots of Fe II lines having lower excitation energies (4.76 to 5.88 eV) were fitted on each linear relationship, implying that their excitations were caused by a dominant thermal process such as collision with energetic electron. However, Fe II lines having higher excitation energies (more than 7.55 eV) had a different behavior from each other. In the ICP, Boltzmann plots of Fe II lines assigned to the higher excited levels also followed the normal Boltzmann relationship among the low-lying excited levels, even including a deviation from it in particular excited levels having an excitation energy of ca. 7.8 eV. This deviation can be attributed to a charge-transfer collision with argon ion, which results in the overpopulation of these excited levels, but the contribution is small. On the other hand, the distribution of the high-lying excited levels was non-thermal in the Okamoto-cavity MIP, which did not follow the normal Boltzmann relationship among the low-lying excited levels. A probable reason for the non-thermal characteristics in the MIP is that a charge-transfer collision with nitrogen molecule ion having many vibrational/rotational levels could work for populating the 3d{sup 6}4p (3d{sup 5}4s4p) excited levels of iron ion broadly over an energy range of 7.6–9.0 eV, while collisional excitation by energetic electron would occur insufficiently to excite these high-energy levels. - Highlights: • This paper describes the excitation mechanism of iron ion in Okamoto-cavity MIP in comparison with conventional ICP. • Boltzmann distribution is studied among iron ionic lines of

  13. Investigation of local thermodynamic equilibrium of laser induced Al2O3–TiC plasma in argon by spatially resolved optical emission spectroscopy

    Directory of Open Access Journals (Sweden)

    K. Alnama

    2016-06-01

    Full Text Available Plasma plume of Al2O3–TiC is generated by third harmonic Q-switched Nd:YAG nanosecond laser. It is characterized using Optical Emission Spectroscopy (OES at different argon background gas pressures 10, 102, 103, 104 and 105 Pa. Spatial evolution of excitation and ionic temperatures is deduced from spectral data analysis. Temporal evolution of Ti I emission originated from different energy states is probed. The correlation between the temporal behavior and the spatial temperature evolution are investigated under LTE condition for the possibility to use the temporal profile of Ti I emission as an indicator for LTE validity in the plasma.

  14. Investigation of local thermodynamic equilibrium of laser induced Al2O3-TiC plasma in argon by spatially resolved optical emission spectroscopy

    Science.gov (United States)

    Alnama, K.; Alkhawwam, A.; Jazmati, A. K.

    2016-06-01

    Plasma plume of Al2O3-TiC is generated by third harmonic Q-switched Nd:YAG nanosecond laser. It is characterized using Optical Emission Spectroscopy (OES) at different argon background gas pressures 10, 102, 103, 104 and 105 Pa. Spatial evolution of excitation and ionic temperatures is deduced from spectral data analysis. Temporal evolution of Ti I emission originated from different energy states is probed. The correlation between the temporal behavior and the spatial temperature evolution are investigated under LTE condition for the possibility to use the temporal profile of Ti I emission as an indicator for LTE validity in the plasma.

  15. The application of cold-plasma coagulation on the visceral pleura results in a predictable depth of necrosis without fistula generation.

    Science.gov (United States)

    Hoffmann, Martin; Ulrich, Anita; Schloericke, Erik; Limmer, Stefan; Habermann, Jens Karsten; Wolken, Heike; Bruch, Hans-Peter; Kujath, Peter

    2012-03-01

    A technique for the safe transfer of electric energy to the pulmonary surface for the potential evaporation of malignant tumours is non-existent to date. By conducting the current study, we wanted to generate data on the potential beneficiary effects and complications of using cold-plasma coagulation on the pulmonary surface. Cold-plasma coagulation was applied to the pulmonary surface in eight female mini-pigs via a thoracoscopic access. After 12 days, we performed a re-thoracoscopy on the contralateral side. After a further 12 days, we performed a median sternotomy and did cold-plasma coagulation on previously untreated areas of either lung. No pulmonary fistulas were detected. In two of the eight pigs, we found a localized chronic pneumonia. None of the pigs died during the course of the study. Morbidity was also low with two pigs refusing food intake, one pig with dyspnoea after difficult intubation and one pig coughing. All events were self-limited and occurred only on post-operative Day 1. The treatment effect was almost linear and correlated to the generator energy applied. The differences between the effects reached statistical significance (P < 0.05). The application of cold-plasma coagulation to the pulmonary surface is safe in pigs. A potential clinical application of this technique is treatment of malignant pleural mesothelioma.

  16. On the difference between breakdown and quench voltages of argon plasma and its relation to $4p-4s$ atomic state transitions

    CERN Document Server

    Forati, Ebrahim; Sievenpiper, Dan

    2014-01-01

    Using a relaxation oscillator circuit, breakdown ($V_{\\mathrm{BD}}$) and quench ($V_{\\mathrm{Q}}$) voltages of a DC discharge microplasma between two needle probes are measured. High resolution modified Paschen curves are obtained for argon microplasmas including a quench voltage curve representing the voltage at which the plasma turns off. It is shown that, for a point to point microgap (e.g. the microgap between two needle probes) which describes many realistic microdevices, neither Paschen's law applies nor field emission is noticeable. Although normally $V_{\\mathrm{BD}}>V_{\\mathrm{Q}}$, it is observed that depending on environmental parameters of argon, such as pressure and the driving circuitry, plasma can exist in a different state with equal $V_{\\mathrm{BD}}$ and $V_{\\mathrm{Q}}$. Using emission line spectroscopy, it is shown that $V_{\\mathrm{BD}}$ and $V_{\\mathrm{Q}}$ are equal if the atomic excitation by the electric field dipole moment dominantly leads to one of the argon's metastable states ($4P_{5...

  17. On the difference between breakdown and quench voltages of argon plasma and its relation to 4p–4s atomic state transitions

    Energy Technology Data Exchange (ETDEWEB)

    Forati, Ebrahim, E-mail: forati@ieee.org; Piltan, Shiva; Sievenpiper, Dan, E-mail: dsievenpiper@ucsd.edu [University of California San Diego, La Jolla, California 92093 (United States)

    2015-02-02

    Using a relaxation oscillator circuit, breakdown (V{sub BD}) and quench (V{sub Q}) voltages of a DC discharge microplasma between two needle probes are measured. High resolution modified Paschen curves are obtained for argon microplasmas including a quench voltage curve representing the voltage at which the plasma turns off. It is shown that for a point to point microgap (e.g., the microgap between two needle probes) which describes many realistic microdevices, neither Paschen's law applies nor field emission is noticeable. Although normally V{sub BD} > V{sub Q,} it is observed that depending on environmental parameters of argon, such as pressure and the driving circuitry, plasma can exist in a different state with equal V{sub BD} and V{sub Q.} Using emission line spectroscopy, it is shown that V{sub BD} and V{sub Q} are equal if the atomic excitation by the electric field dipole moment dominantly leads to one of the argon's metastable states (4P{sub 5} in our study)

  18. Estimation of Minimal Breakdown Point in a GaP Plasma Structure and Discharge Features in Air and Argon Media

    Science.gov (United States)

    Kurt, H. Hilal; Tanrıverdi, Evrim

    2016-08-01

    We present gas discharge phenomena in argon and air media using a gallium phosphide (GaP) semiconductor and metal electrodes. The system has a large-diameter ( D) semiconductor and a microscaled adjustable interelectrode gap ( d). Both theoretical and experimental findings are discussed for a direct-current (dc) electric field ( E) applied to this structure with parallel-plate geometry. As one of the main parameters, the pressure p takes an adjustable value from 0.26 kPa to 101 kPa. After collection of experimental data, a new theoretical formula is developed to estimate the minimal breakdown point of the system as a function of p and d. It is proven that the minimal breakdown point in the semiconductor and metal electrode system differs dramatically from that in metal and metal electrode systems. In addition, the surface charge density σ and spatial electron distribution n e are calculated theoretically. Current-voltage characteristics (CVCs) demonstrate that there exist certain negative differential resistance (NDR) regions for small interelectrode separations (i.e., d = 50 μm) and low and moderate pressures between 3.7 kPa and 13 kPa in Ar medium. From the difference of currents in CVCs, the bifurcation of the discharge current is clarified for an applied voltage U. Since the current differences in NDRs have various values from 1 μA to 7.24 μA for different pressures, the GaP semiconductor plasma structure can be used in microwave diode systems due to its clear NDR region.

  19. Investigations of the cathode region of an argon arc plasma by degenerate four-wave mixing laser spectroscopy and optical emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dzierzega, K [Marian Smoluchowski Institute of Physics, Jagiellonian University, ul. Reymonta 4, 30-059 Cracow (Poland); Pokrzywka, B [Mt. Suhora Observatory, Cracow Pedagogical University, ul. Podchorazych 2, 30-083 Cracow (Poland); Pellerin, S [LASEP, Universite d' Orleans-Centre Universitaire de Bourges, Rue Gaston Berger BP 4043, 18028 Bourges (France)

    2004-07-07

    Degenerate four-wave mixing (DFWM) laser spectroscopy was used in local studies of atmospheric pressure argon plasma generated in a free-burning arc. The results of plasma diagnostics using the DFWM method were compared to the results obtained with optical emission measurements. In the cathode region of the arc the maxima of both the DFWM signal and the emission coefficient for the 696.5 nm Ar I line depend on the distance from the cathode tip. This effect proves the departure of the plasma state from local thermal equilibrium (LTE) as it has been reported by many authors. On the other hand the Stark shifts of the 696.5 nm Ar I line determined by the DFWM method in relation to plasma diagnostic results show no deviations from LTE on the arc axis down to 1.0 mm from the cathode tip.

  20. Dynamics of the spectral behaviour of an ultrashort laser pulse in an argon-gas-filled capillary discharge-preformed plasma channel

    Directory of Open Access Journals (Sweden)

    Sakai S.

    2013-11-01

    Full Text Available We have reported the argon plasma waveguide produced in an alumina (Al2O3 capillary discharge and used to guide ultrashort laser pulses at intensities of the order of 1016  W/cm2. A one-dimensional magnetohydrodynamic (MHD code was used to evaluate the average degree of ionization of Ar in the preformed plasma channel. The spectrum of the propagated laser pulse in the Ar plasma waveguide was not modified and was well reproduced by a particle-in-cell (PIC simulation under initial ion charge state of Ar3+ in the preformed plasma waveguide. The optimum timing for the laser pulse injection was around 150 ns after initiation of a discharge with a peak current of 200 A.

  1. Characteristic effects onto C13H12N2O3 molecule dissolved in solvents of argon plasma at atmospheric pressure

    Science.gov (United States)

    Tanışlı, Murat; Taşal, Erol

    2017-02-01

    We could easily argue that the decomposition of the chemical chain molecules is a compelling application when it comes to the atmospheric pressure plasma. In this paper, we have investigated the effect of the atmospheric pressure argon plasma on 4-((2-methoxyphenyl)diazenyl)benzene-1,3,-diol molecule (abbreviated as 4MBD) at room temperature. 4MBD molecule is one of the industrial dye molecules used widely. When considering the ecological life, this molecule is very harmful and dangerous. As such, we suggest a new decomposing method for such molecules. Atmospheric pressure plasma jet is principally treated for the breakdown of the molecule in question. Fourier transform infrared spectrometry and UV-Vis spectrophotometry tools are used to characterization of the molecules subsequent to the plasma applications to 4MBD molecule in ethanol and methanol solvents. The atmospheric-pressure plasma jet of argon (Ar) as non-equilibrium has been formed by ac-power generator with frequency—24 kHz and voltage—12 kV. Characterizations for solutions prepared with ethanol and methanol solvents of 4MBD molecule have been examined after applying (duration 3 min) the atmospheric pressure plasma jet. The molecule is broken at 6C-7N-8N=9C stretching peak in consequence of the plasma treatment. The new plasma photo-products for ethanol and methanol solutions are produced as 6C-7N-8N=9C (strong, varying) and 12C=17O (strong, wide) stretching peaks. Also, the bathochromic drifts are discerned.

  2. Retention of coagulation factors in plasma frozen after extended holding at 1-6 degrees C

    NARCIS (Netherlands)

    Smith, JF; Ness, PM; Moroff, G; Luban, NLC

    2000-01-01

    Background and Objectives: The ability to use plasma, isolated from units of whole blood and frozen within 24 h of phlebotomy, as a substitute for plasma frozen within 8 h of phlebotomy would have several advantages for blood centers. It should provide increased flexibility pertaining to the freezin

  3. Argon plasma inductively coupled plasma reactive ion etching study for smooth sidewall thin film lithium niobate waveguide application

    Science.gov (United States)

    Ulliac, G.; Calero, V.; Ndao, A.; Baida, F. I.; Bernal, M.-P.

    2016-03-01

    Lithium Niobate (LN) exhibits unique physical properties such as remarkable electro-optical coefficients and it is thus an excellent material for a wide range of fields like optic communications, lasers, nonlinear optical applications, electric field optical sensors etc. In order to further enhance the optical device performance and to be competitive with silicon photonics, sub-micrometric thickness lithium niobate films are crucial. A big step has been achieved with the development of LN thin films by using smart cut technology and wafer bonding and these films are nowadays available in the market. However, it is a challenge to obtain the requirements of the high quality thin LN film waveguide. In this letter, we show smooth ridge waveguides fabricated on 700 nm thickness thin film lithium niobate (TFLN). The fabrication has been done by developing and optimizing three steps of the technological process, the mask fabrication, the plasma etching, and a final cleaning wet etching step in order to remove the lithium niobate redeposition on the side walls. We have obtained single mode propagation with light overall losses of only 5 dB/cm.

  4. Contribution of a portable air plasma torch to rapid blood coagulation as a method of preventing bleeding

    Science.gov (United States)

    Kuo, S. P.; Tarasenko, O.; Chang, J.; Popovic, S.; Chen, C. Y.; Fan, H. W.; Scott, A.; Lahiani, M.; Alusta, P.; Drake, J. D.; Nikolic, M.

    2009-11-01

    The effectiveness and mechanism of a low temperature air plasma torch in clotting blood are explored. Both blood droplets and smeared blood samples were used in the tests. The treated droplet samples reveal how blood clotting depends on the distance at which the torch operated, and for how long the droplets have been exposed to the torch. Microscopy and cell count of smeared blood samples shed light on dependencies of erythrocyte and platelet counts on torch distance and exposure time. With an increase of torch distance, the platelet count of treated blood samples increases but is less than that of the control. The flux of reactive atomic oxygen (RAO) and the degree of blood clotting decreased. With an increase of exposure time, platelet count of treated samples decreased, while the degree of clot increased. The correlation among these dependencies and published data support a blood clotting mechanism that RAO as well as other likely reactive oxygen species generated by the plasma torch activate erythrocyte-platelets interactions and induces blood coagulation.

  5. Quality Control and Assurance for Coagulation Tests

    Institute of Scientific and Technical Information of China (English)

    彭黎明

    2006-01-01

    @@ The coagulation laboratory aids the clinician in assessing not only the bleeding patient but also the thrombotic patient. The techniques of coagulation laboratory are used to evaluate not only the coagulation system but also the anti-coagulation system, fibrinolytic system,platelet and vascular endothelial function. Enzymes, inhibitors, plasma factors and co-factors, cellular release products, and cell receptors can be measured in coagulation laboratory.

  6. Mechanisms of suppressing secondary nucleation for low-power and low-temperature microwave plasma self-bias-enhanced growth of diamond films in argon diluted methane

    Directory of Open Access Journals (Sweden)

    Ji-heng Jiang

    2011-12-01

    Full Text Available We report on mechanisms for suppressing diamond secondary nucleation in microwave plasma self-bias-enhanced growth (SBEG of diamond films in methane diluted by argon. High-density plasma at a small distance from the substrate induces a floating potential which promotes high-flux, low-energy ion bombardment on diamond growing surfaces along with an equal flux of electrons. Increased atomic hydrogen generated by electron impact dissociation of methane and low-energy ion bombardment help remove hydrocarbon coatings on diamond grains in favor of continuous grain growth and, therefore, the suppression of secondary diamond nucleation. Energetic meta-stable excited argon, abundant C2 dimers, and enhanced effective surface temperature due to low-energy ion bombardment further promote the diamond grain growth resulting in the deposition of a diamond film with columnar diamond grains of much larger grain sizes and a much lower density of grain boundaries than ultrananocrystalline diamond (UNCD films grown under similar conditions without optimized plasma-substrate interactions. SEM, XRD, PL, and Raman scattering help confirm the deposition of diamond films with columnar grains.

  7. COAGULATION ACTIVITY IN LIVER DISEASE

    Directory of Open Access Journals (Sweden)

    Dr. Sheikh Sajjadieh Mohammad Reza

    2009-07-01

    Full Text Available Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation markers were assayed in 60 participants: 20 patients with chronic hepatitis, 20 patients with cirrhosis, and 20 healthy individuals (control. Plasma levels of anti-thrombin III were determined by a chromogenic substrate method, and plasma concentrations of fibrinogen were analyzed by the Rutberg method. Commercially available assays were used for laboratory coagulation tests. The levels of coagualation activity markers in patients with chronic liver disease were significantly different in comparison to those in healthy participants. These results indicate the utility of measuring markers for coagulation activity in determining which cirrhosis patients are more susceptible to disseminated intravascular coagulation.

  8. 大气氛围中氩气等离子体射流的数值模拟%Numerical Simulation on Argon Plasma Jet in Atmospheric Ambient

    Institute of Scientific and Technical Information of China (English)

    邵先军; 张冠军; 李娅西; 张增辉; 詹江杨

    2011-01-01

    In order to analyze the characteristics of Argon plasma jet under atmospheric air environment, a two-dimensional axis-symmetrical spurt model of plasma jet was established, in which the influences of a material work piece on plasma jet was considered, the Jets&Poudres software was employed to solve the compressible N-S equations, energy equation and K-e turbulence equation, and the free boundary was used to deal with the outside boundary condition of plasma jet. Moreover, the plasma temperature, velocity and air percentage composition in plasma were analyzed, and the effects of Argon flow rates and nozzle diameters on spurt properties were also researched. The results show that, the distributions of plasma temperature and axial velocity present as inverted cone shape, and the distributions of attenuations of temperature and axial velocity are behaved as Gaussian function; The maximum value of radial velocity is 1% that of axis velocity, which appears at the tail of plasma jet; As Argon flow rates increase, the axial velocities of plasma jet increase apparently, and the plasma temperatures decrease gradually, indicating that the cool effect of plasma jet is enlarged at high gas flow rate; As nozzle diameters increase, the plasma temperatures increase gradually, and the peak values of axial velocities decrease sharply although the minimum values of axial velocities keep constant. Furthermore, in the region of high plasma temperature and velocity, it is difficult for air to enter, and the air percentages in this region are almost around 3%~5%.%为了分析大气压空气环境中氩气等离子体射流的特性,建立了二维轴对称的等离子体射流喷射模型;考虑待处理材料对等离子体射流的影响,利用Jets&Poudres软件耦合求解了等离子体射流的可压缩N—s方程、能量方程以及K-e湍流方程;采用自由边界条件来处理射流等离子体的外边界条件,分析了射流等离子体的温度、速度以

  9. Study on the effect of hydrogen addition on the variation of plasma parameters of argon-oxygen magnetron glow discharge for synthesis of TiO2 films

    Directory of Open Access Journals (Sweden)

    Partha Saikia

    2016-04-01

    Full Text Available We report the effect of hydrogen addition on plasma parameters of argon-oxygen magnetron glow discharge plasma in the synthesis of H-doped TiO2 films. The parameters of the hydrogen-added Ar/O2 plasma influence the properties and the structural phases of the deposited TiO2 film. Therefore, the variation of plasma parameters such as electron temperature (Te, electron density (ne, ion density (ni, degree of ionization of Ar and degree of dissociation of H2 as a function of hydrogen content in the discharge is studied. Langmuir probe and Optical emission spectroscopy are used to characterize the plasma. On the basis of the different reactions in the gas phase of the magnetron discharge, the variation of plasma parameters and sputtering rate are explained. It is observed that the electron and heavy ion density decline with gradual addition of hydrogen in the discharge. Hydrogen addition significantly changes the degree of ionization of Ar which influences the structural phases of the TiO2 film.

  10. Surface modification with poly(sulfobetaine methacrylate-co-acrylic acid) to reduce fibrinogen adsorption, platelet adhesion, and plasma coagulation.

    Science.gov (United States)

    Kuo, Wei-Hsuan; Wang, Meng-Jiy; Chien, Hsiu-Wen; Wei, Ta-Chin; Lee, Chiapyng; Tsai, Wei-Bor

    2011-12-12

    Zwitterionic sulfobetaine methacrylate (SBMA) polymers were known to possess excellent antifouling properties due to high hydration capacity and neutral charge surface. In this study, copolymers of SBMA and acrylic acid (AA) with a variety of compositions were synthesized and were immobilized onto polymeric substrates with layer-by-layer polyelectrolyte films via electrostatic interaction. The amounts of platelet adhesion and fibrinogen adsorption were determined to evaluate hemocompatibility of poly(SBMA-co-AA)-modified substrates. Among various deposition conditions by modulating SBMA ratio in the copolymers and pH of the deposition solution, poly(SBMA(56)-co-AA(44)) deposited at pH 3.0 possessed the best hemocompatibility. This work demonstrated that poly(SBMA-co-AA) copolymers adsorbed on polyelectrolyte-base films via electrostatic interaction improve hemocompatibility effectively and are applicable for various substrates including TCPS, PU, and PDMS. Furthermore, poly(SBMA-co-AA)-coated substrate possesses great durability under rigorous conditions. The preliminary hemocompatibility tests regarding platelet adhesion, fibrinogen adsorption, and plasma coagulation suggest the potential of this technique for the application to blood-contacting biomedical devices.

  11. Deviation from Boltzmann distribution in excited energy levels of singly-ionized iron in an argon glow discharge plasma for atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lei; Kashiwakura, Shunsuke; Wagatsuma, Kazuaki, E-mail: wagatuma@imr.tohoku.ac.jp

    2012-01-15

    A Boltzmann plot for many iron ionic lines having excitation energies of 4.7-9.1 eV was investigated in an argon glow discharge plasma when the discharge parameters, such as the voltage/current and the gas pressure, were varied. A Grimm-style radiation source was employed in a DC voltage range of 400-800 V at argon pressures of 400-930 Pa. The plot did not follow a linear relationship over a wide range of the excitation energy, but it yielded a normal Boltzmann distribution in the range of 4.7-5.8 eV and a large overpopulation in higher-lying excitation levels of iron ion. A probable reason for this phenomenon is that excitations for higher excited energy levels of iron ion would be predominantly caused by non-thermal collisions with argon species, the internal energy of which is received by iron atoms for the ionization. Particular intense ionic lines, which gave a maximum peak of the Boltzmann plot, were observed at an excitation energy of ca. 7.7 eV. They were the Fe II 257.297-nm and the Fe II 258.111-nm lines, derived from the 3d{sup 5}4s4p {sup 6}P excited levels. The 3d{sup 5}4s4p {sup 6}P excited levels can be highly populated through a resonance charge transfer from the ground state of argon ion, because of good matching in the excitation energy as well as the conservation of the total spin before and after the collision. An enhancement factor of the emission intensity for various Fe II lines could be obtained from a deviation from the normal Boltzmann plot, which comprised the emission lines of 4.7-5.8 eV. It would roughly correspond to a contribution of the charge transfer excitation to the excited levels of iron ion, suggesting that the charge-transfer collision could elevate the number density of the corresponding excited levels by a factor of ca.10{sup 4}. The Boltzmann plots give important information on the reason why a variety of iron ionic lines can be emitted from glow discharge plasmas.

  12. A sequence variation scan of the coagulation factor VIII (FVIII) structural gene and associations with plasma FVIII activity levels.

    Science.gov (United States)

    Viel, Kevin R; Machiah, Deepa K; Warren, Diane M; Khachidze, Manana; Buil, Alfonso; Fernstrom, Karl; Souto, Juan C; Peralta, Juan M; Smith, Todd; Blangero, John; Porter, Sandra; Warren, Stephen T; Fontcuberta, Jordi; Soria, Jose M; Flanders, W Dana; Almasy, Laura; Howard, Tom E

    2007-05-01

    Plasma factor VIII coagulant activity (FVIII:C) level is a highly heritable quantitative trait that is strongly correlated with thrombosis risk. Polymorphisms within only 1 gene, the ABO blood-group locus, have been unequivocally demonstrated to contribute to the broad population variability observed for this trait. Because less than 2.5% of the structural FVIII gene (F8) has been examined previously, we resequenced all known functional regions in 222 potentially distinct alleles from 137 unrelated nonhemophilic individuals representing 7 racial groups. Eighteen of the 47 variants identified, including 17 single-nucleotide polymorphisms (SNPs), were previously unknown. As the degree of linkage disequilibrium across F8 was weak overall, we used measured-genotype association analysis to evaluate the influence of each polymorphism on the FVIII:C levels in 398 subjects from 21 pedigrees known as the Genetic Analysis of Idiopathic Thrombophilia project (GAIT). Our results suggested that 92714C>G, a nonsynonymous SNP encoding the B-domain substitution D1241E, was significantly associated with FVIII:C level. After accounting for important covariates, including age and ABO genotype, the association persisted with each C-allele additively increasing the FVIII:C level by 14.3 IU dL(-1) (P = .016). Nevertheless, because the alleles of 56010G>A, a SNP within the 3' splice junction of intron 7, are strongly associated with 92714C>G in GAIT, additional studies are required to determine whether D1241E is itself a functional variant.

  13. Measurement of ion density in an atmospheric pressure argon with pin-to-plate dielectric barrier discharge by resonance of plasma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Bing, E-mail: qibing@szu.edu.cn; Pan, Lizhu; Zhou, Qiujiao; Huang, Jianjun; Liu, Ying [Applied Low Temperature Plasma Laboratory, School of Physics, Shenzhen University, Shenzhen 518060 (China)

    2014-12-15

    The measurements of the ion densities in the atmospheric AC barrier corona argon discharge are carried out by receiving and analyzing the frequencies of the electromagnetic radiation emitted from the plasma. An auxiliary excitation source composed of a pin-to-pin discharge system is introduced to excite the oscillations of the main discharge. To analyze the resonance mechanism, a complemented model based on a one-dimensional description of forced vibrations is given. Calculations indicate that Ar{sub 2}{sup +} is the dominant ion (∼89% in number density). By analyzing resonance frequencies, the ion densities of Ar{sub 2}{sup +} are in the order of 10{sup 19}∼10{sup 20}m{sup −3} and increase slowly as the applied voltage increases.

  14. Measurement of ion density in an atmospheric pressure argon with pin-to-plate dielectric barrier discharge by resonance of plasma radiation

    Science.gov (United States)

    Qi, Bing; Pan, Lizhu; Zhou, Qiujiao; Huang, Jianjun; Liu, Ying

    2014-12-01

    The measurements of the ion densities in the atmospheric AC barrier corona argon discharge are carried out by receiving and analyzing the frequencies of the electromagnetic radiation emitted from the plasma. An auxiliary excitation source composed of a pin-to-pin discharge system is introduced to excite the oscillations of the main discharge. To analyze the resonance mechanism, a complemented model based on a one-dimensional description of forced vibrations is given. Calculations indicate that Ar2 + is the dominant ion ( ˜ 89 % in number density). By analyzing resonance frequencies, the ion densities of Ar2 + are in the order of 10 19 ˜ 10 20 m - 3 and increase slowly as the applied voltage increases.

  15. Influence of low energy argon plasma treatment on the moisture barrier performance of hot wire-CVD grown SiNx multilayers

    Science.gov (United States)

    Majee, Subimal; Fátima Cerqueira, Maria; Tondelier, Denis; Geffroy, Bernard; Bonnassieux, Yvan; Alpuim, Pedro; Bourée, Jean Eric

    2014-01-01

    The reliability and stability are key issues for the commercial utilization of organic photovoltaic devices based on flexible polymer substrates. To increase the shelf-lifetime of these devices, transparent moisture barriers of silicon nitride (SiNx) films are deposited at low temperature by hot wire CVD (HW-CVD) process. Instead of the conventional route based on organic/inorganic hybrid structures, this work defines a new route consisting in depositing multilayer stacks of SiNx thin films, each single layer being treated by argon plasma. The plasma treatment allows creating smoother surface and surface atom rearrangement. We define a critical thickness of the single layer film and focus our attention on the effect of increasing the number of SiNx single-layers on the barrier properties. A water vapor transmission rate (WVTR) of 2 × 10-4 g/(m2·day) is reported for SiNx multilayer stack and a physical interpretation of the plasma treatment effect is given.

  16. Charge-state and element-resolved ion energies in the cathodic arc plasma from composite AlCr cathodes in argon, nitrogen and oxygen atmospheres

    CERN Document Server

    Franz, Robert; Anders, André

    2014-01-01

    The energy distribution functions of ions in the cathodic arc plasma using composite AlCr cathodes were measured as a function of the background gas pressure in the range 0.5 to 3.5 Pa for different cathode compositions and gas atmospheres. The most abundant aluminium ions were Al$^{+}$ regardless of the background gas species, whereas Cr$^{2+}$ ions were dominating in Ar and N$_2$ and Cr$^{+}$ in O$_2$ atmospheres. The energy distributions of the aluminium and chromium ions typically consisted of a high energy fraction due to acceleration in the expanding plasma plume from the cathode spot and thermalised ions that were subjected to collisions in the plasma cloud. The fraction of the latter increased with increasing background gas pressure. Atomic nitrogen and oxygen ions showed similar energy distributions as the aluminium and chromium ions, whereas the argon and molecular nitrogen and oxygen ions were mainly thermalised. In addition to the positively charged metal and gas ions, negatively charged oxygen an...

  17. Spectroscopy of reactive species produced by low-energy atmospheric-pressure plasma on conductive target material surface

    Science.gov (United States)

    Yamada, Hiromasa; Sakakita, Hajime; Kato, Susumu; Kim, Jaeho; Kiyama, Satoru; Fujiwara, Masanori; Itagaki, Hirotomo; Okazaki, Toshiya; Ikehara, Sanae; Nakanishi, Hayao; Shimizu, Nobuyuki; Ikehara, Yuzuru

    2016-10-01

    A method for blood coagulation using low-energy atmospheric-pressure plasma (LEAPP) is confirmed as an alternative procedure to reduce tissue damage caused by heat. Blood coagulation using LEAPP behaves differently depending on working gas species; helium is more effective than argon in promoting fast coagulation. To analyse the difference in reactive species produced by helium and argon plasma, spectroscopic measurements were conducted without and with a target material. To compare emissions, blood coagulation experiments using LEAPP for both plasmas were performed under almost identical conditions. Although many kinds of reactive species such as hydroxyl radicals and excited nitrogen molecules were observed with similar intensity in both plasmas, intensities of nitrogen ion molecules and nitric oxide molecules were extremely strong in the helium plasma. It is considered that nitrogen ion molecules were mainly produced by penning ionization by helium metastable. Near the target, a significant increase in the emissions of reactive species is observed. There is a possibility that electron acceleration was induced in a local electric field formed on the surface. However, in argon plasma, emissions from nitrogen ion were not measured even near the target surface. These differences between the two plasmas may be producing the difference in blood coagulation behaviour. To control the surrounding gas of the plasma, a gas-component-controllable chamber was assembled. Filling the chamber with O2/He or N2/He gas mixtures selectively produces either reactive oxygen species or reactive nitrogen species. Through selective treatments, this chamber would be useful in studying the effects of specific reactive species on blood coagulation.

  18. Proteome of human plasma very low-density lipoprotein and low-density lipoprotein exhibits a link with coagulation and lipid metabolism.

    Science.gov (United States)

    Dashty, M; Motazacker, M M; Levels, J; de Vries, M; Mahmoudi, M; Peppelenbosch, M P; Rezaee, F

    2014-03-03

    Apart from transporting lipids through the body, the human plasma lipoproteins very low-density lipoprotein (VLDL) and low-density lipoprotein (LDL) are also thought to serve as a modality for intra-organismal protein transfer, shipping proteins with important roles in inflammation and thrombosis from the site of synthesis to effector locations. To better understand the role of VLDL and LDL in the transport of proteins, we applied a combination of LTQ ORBITRAP-XL (nLC-MS/MS) with both in-SDS-PAGE gel and in-solution tryptic digestion of pure and defined VLDL and LDL fractions. We identified the presence of 95 VLDL- and 51 LDL-associated proteins including all known apolipoproteins and lipid transport proteins, and intriguingly a set of coagulation proteins, complement system and anti- microbial proteins. Prothrombin, protein S, fibrinogen γ, PLTP, CETP, CD14 and LBP were present on VLDL but not on LDL. Prenylcysteine oxidase 1, dermcidin, cathelicidin antimicrobial peptide, TFPI-1 and fibrinogen α chain were associated with both VLDL and LDL. Apo A-V is only present on VLDL and not on LDL. Collectively, this study provides a wealth of knowledge on the protein constituents of the human plasma lipoprotein system and strongly supports the notion that protein shuttling through this system is involved in the regulation of biological processes. Human diseases related to proteins carried by VLDL and LDL can be divided in three major categories: 1 - dyslipidaemia, 2 - atherosclerosis and vascular disease, and 3 - coagulation disorders.

  19. Study on Blood Coagulant/Fibrinolytic Activity at Plasma andMonocytic Levels in Coronary Heart Disease Patients withBlood-Stasis Syndrome of Traditional Chinese Medicine

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective: To explore and compare the changes of coagulant/fibrinolytic activity in coronary heart disease (CHD) patients with Blood Stasis Syndrome of TCM and evaluate the roles of these changes. Methods: Eighty patients of CHD were divided into two groups by Syndrome Differentiation of TCM, the Blood-Stasis (BS) group (30 cases) and the non-Blood-Stasis (NBS) group (50 cases, including 27 cases of Phlegm-Dampness Syndrome and 23 cases of Qi-Stagnation Syndrome); and 20 healthy persons were enrolled as normal control group. Tissue type plasminogen activator (t-PA) and its inhibitor (PAI-1) in plasma and in human peripheral blood monocyte cell (PBMC), as well as the procoagulant activity (PCA) in PBMC were measured by chromogenic substrate method. Results: The plasma PAI-1 activity and PCA of PBMC in the BS group were significantly higher than those in the NBS group and the normal control group (P<0.01). PAI-1 activity of PBMC in the two groups of CHD patients was higher than those in the normal control group significantly (P<0.01), but no significant difference was found between the BS group and the NBS group (P>0.05). The difference of plasma t-PA activity between the two groups of CHD was insignificant. The PBMC t-PA activity in the BS group was lower than that in the NBS and normal control groups (P<0.01). Conclusion: In the CHD patients with BS, the PBMC PCA was increased and the fibrinolytic activity at both plasma and monocyte levels lowered significantly, these changes in coagulant/fibrinolytic activity may be the important pathologic factors in forming BS which suggests that CHD patients with BS were in the prothrombotic state.

  20. A differentially pumped argon plasma in the linear plasma generator Magnum-PSI: gas flow and dynamics of the ionized fraction

    NARCIS (Netherlands)

    van Eck, H. J. N.; Hansen, T. A. R.; Kleyn, A. W.; van der Meiden, H. J.; D.C. Schram,; van Emmichoven, P. A. Zeijlma

    2011-01-01

    Magnum-PSI is a linear plasma generator designed to reach the plasma-surface interaction (PSI) regime of ITER and nuclear fusion reactors beyond ITER. To reach this regime, the influx of cold neutrals from the source must be significantly lower than the plasma flux reaching the target. This is achie

  1. In vitro study of safety and co-efficiency of the transbronchial coagulation techniques

    Institute of Scientific and Technical Information of China (English)

    BAI Chong; DONG Yu-chao; SONG Xiao-lian; HUANG Yi; SHI Hui; HU Zhen-li; LI Qiang

    2013-01-01

    Background The usual transbronchial coagulation techniques include microwave,argon plasma coagulation (APC),electrocautery and cryotherapy.However,there are serious clinical problems in the safety of each.By analyzing the experimental data and clinical observations,we observed the variable effects of different coagulation techniques via bronchofibroscopy,to look for an optimal interventional management of luminal bronchus diseases,and evaluate the safety and the equivalent point.Methods Four kinds of coagulation techniques under bronchoscopy were performed on the fresh bronchus of healthy sheep,and the pathologic changes in all groups were observed under the microscope.The different treatment parameters were as follows:microwave 60 W×1 second,3 seconds,5 seconds and 40 W×1 second,3 seconds,5 seconds; APC 40 W×1 second,3 seconds,5 seconds; electrocautery 40 W×1 second,3 seconds,5 seconds;cryotherapy 100 Ω×60 seconds,120 seconds.Results After treatment,ovine bronchial mucosa in all groups showed pathologic changes such as local necrosis and amotio of the mucosa lining epithelium,local submucosa coagulative necrosis or tissue defects,while inflammation in the surrounding tissue was not obvious.Under the same output power and action time,different methods had different outcomes.The damage by APC was the most superficial,microwave was the second,and electrocautery caused the worst damage.The study also found that effects of electrocautery at 40 W×3 seconds,microwave at 40 W×5 seconds or 60 W×3 seconds,APC at 40 W×5 seconds and cryotherapy at 100 Ω×120 seconds were the equivalent point conditions.The appearance included mucosa absence,partial submucosa absence,and collagen fiber coagulation in treatment areas.Conclusions Each coagulation technique has its own characteristic.It is very important to choose the appropriate power and action time of the suitable method according to the therapy requirement.

  2. Photocatalytic property of titanium dioxide thin films deposited by radio frequency magnetron sputtering in argon and water vapour plasma

    Energy Technology Data Exchange (ETDEWEB)

    Sirghi, L., E-mail: lsirghi@uaic.ro [Department of Physics, Alexandru Ioan Cuza University, Blvd. Carol I, 11, Iasi, 700506 (Romania); Hatanaka, Y. [Research Institute of Electronics, Shizuoka University, 3-5-1, Johoku Naka-ku Hamamatsu, 432-8011 (Japan); Sakaguchi, K. [Faculty of Engineering, Aichi University of Technology, 50-2 Manori, Nishihazama, Gamagori, 443-0047 Aichi (Japan)

    2015-10-15

    Highlights: • TiOx thin films were deposited by radio frequency magnetron sputtering in Ar and Ar/H{sub 2}O plasma. • The deposited films contain OH groups in their bulk structure irrespective of the water content of the working gas. • The structure and photocatalytic activity of the deposited films were studied. - Abstract: The present work is investigating the photocatalytic activity of TiO{sub 2} thin films deposited by radiofrequency magnetron sputtering of a pure TiO{sub 2} target in Ar and Ar/H{sub 2}O (pressure ratio 40/3) plasmas. Optical absorption, structure, surface morphology and chemical structure of the deposited films were comparatively studied. The films were amorphous and included a large amount of hydroxyl groups (about 5% of oxygen atoms were bounded to hydrogen) irrespective of the intentional content of water in the deposition chamber. Incorporation of hydroxyl groups in the film deposited in pure Ar plasma is explained as contamination of the working gas with water molecules desorbed by plasma from the deposition chamber walls. However, intentional input of water vapour into the discharge chamber decreased the deposition speed and roughness of the deposited films. The good photocatalytic activity of the deposited films could be attributed hydroxyl groups in their structures.

  3. Plasma triacylglycerol and coagulation factor concentrations predict the anticoagulant effect of dietary fish oil in overweight subjects

    DEFF Research Database (Denmark)

    Vanschoonbeek, Kristof; Feijge, Marion A H; Saris, Wim H M;

    2007-01-01

    determined partly the interindividual variation in thrombin generation, of which prothrombin and triacylglycerol concentrations were the main determinants. In both healthy subjects and diabetes patients, high triacylglycerol concentrations (>1.69 mmol/L) at baseline were closely linked to a strong fish oil......-induced lowering of triacylglycerol and coagulation factor V, VII, and X concentrations, and thrombin generation. We conclude that high fasting triacylglycerol concentrations predict high procoagulant activity and a lowering of thrombin potential with dietary fish oil....

  4. Performance of coagulation tests in patients on therapeutic doses of rivaroxaban. A cross-sectional pharmacodynamic study based on peak and trough plasma levels.

    Science.gov (United States)

    Francart, Suzanne J; Hawes, Emily M; Deal, Allison M; Adcock, Dorothy M; Gosselin, Robert; Jeanneret, Cheryl; Friedman, Kenneth D; Moll, Stephan

    2014-06-01

    Knowledge of anticoagulation status during rivaroxaban therapy is desirable in certain clinical situations. It was the study objective to determine coagulation tests most useful for assessing rivaroxaban's anticoagulant effect. Peak and trough blood samples from 29 patients taking rivaroxaban 20 mg daily were collected. Mass spectrometry and various coagulation assays were performed. "On-therapy range" was defined as the rivaroxaban concentrations determined by LC-MS/MS. A "misprediction percentage" was calculated based on how often results of each coagulation assay were in the normal reference range, while the rivaroxaban concentration was in the "on-therapy" range. The on-therapy range was 8.9-660 ng/ml. The misprediction percentages for prothrombin time (PT) and activated partial thromboplastin time (aPTT), using multiple reagents and coagulometers, ranged from 10%-52% and 31%-59%, respectively. PT, aPTT and activated clotting time (ACT) were insensitive to trough rivaroxaban: 59%, 62%, and 80% of samples had a normal result, respectively. Over 95% of PT and ACT values were elevated at peak. Four different rivaroxaban calibrated anti-Xa assays had R² values >0.98, demonstrating strong correlations with rivaroxaban drug levels. In conclusion, PT, aPTT and ACT are often normal in patients on therapeutic doses of rivaroxaban. However, PT and ACT may have clinical utility at higher drug plasma levels. Rivaroxaban calibrated anti-factor Xa assays can accurately identify low and high on-therapy rivaroxaban drug levels and, therefore, have superior utility in all clinical situations where assessment of anticoagulation status may be beneficial.

  5. Argon ion beam interaction on polyethylene terephthalate surface by a 4 kJ plasma focus device

    Indian Academy of Sciences (India)

    Habibi Morteza; Alavi M H S

    2016-03-01

    Polyethylene terephthalate (PET) has a wide variety of applications ranging from making regular bottles to biosensors. However, for many of these applications, surface treatment is needed to improve its surface characteristics such as adhesion to other materials. In this study, we focussed on treating PET foils by dense Ar pulsed plasma produced by a 4.5 kJ Mather-type plasmafocus device (20 kV, 40 $\\mu$f, 115 nH) to examine its ability to make the PET surface hydrophilic. The most common method to examine this characteristic is measuring the water contact angle on a polymer surface. The results show that while the energy and density of plasma in our device are higher compared to other devices, as the exposure time is very low, the device can enhance thewettability of PET film surfaces.

  6. Irradiation influence on Mylar and Makrofol induced by argon ions in a plasma immersion ion implantation system

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, A. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Aal, S.A. Abd El [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Ghazaly, M. El [Physiology Department, College of Medicine, Taif University, P.O. 888, Taif (Saudi Arabia); Physics Department, Faculty of Science, Zagazig University, P.O. 44519, Zagazig (Egypt)

    2015-08-30

    Highlights: • A home-built plasma immersion ion implantation system was tested in modifying surfaces. • Wettability modifications within the energy range 10 keV implantation are not investigated elsewhere, up to our knowledge. • The wettability of Mylar and Makrofol surface was enhanced by the dual effect of ion implantation and plasma treatment. • The improved wettability was found to depend on both surface roughness and chemistry. • The adhesive bonding and surface energy of the polymers are improved. - Abstract: Mylar and Makrofol polycarbonate polymers were irradiated by Ar ions in a plasma immersion ion implantation (PIII) system. The surface wettability of both polymers was investigated by employing the contact angle method. The measured contact angles were found to depend on the surface layer properties. Good wetting surfaces were found to depend not only on surface roughness but also on its chemistry that analyzed by Fourier transform infrared (FTIR) spectroscopy. Surfaces topography and roughness was investigated and correlated to their surface energy which studied with the aid of acid-base model for evaluating the improvement of surface wettability after irradiation. PIII improves polymers surface properties efficiently in a controllable way.

  7. UPLC-MRM Mass Spectrometry Method for Measurement of the Coagulation Inhibitors Dabigatran and Rivaroxaban in Human Plasma and Its Comparison with Functional Assays.

    Directory of Open Access Journals (Sweden)

    Joachim Kuhn

    Full Text Available The fast, precise, and accurate measurement of the new generation of oral anticoagulants such as dabigatran and rivaroxaban in patients' plasma my provide important information in different clinical circumstances such as in the case of suspicion of overdose, when patients switch from existing oral anticoagulant, in patients with hepatic or renal impairment, by concomitant use of interaction drugs, or to assess anticoagulant concentration in patients' blood before major surgery.Here, we describe a quick and precise method to measure the coagulation inhibitors dabigatran and rivaroxaban using ultra-performance liquid chromatography electrospray ionization-tandem mass spectrometry in multiple reactions monitoring (MRM mode (UPLC-MRM MS. Internal standards (ISs were added to the sample and after protein precipitation; the sample was separated on a reverse phase column. After ionization of the analytes the ions were detected using electrospray ionization-tandem mass spectrometry. Run time was 2.5 minutes per injection. Ion suppression was characterized by means of post-column infusion.The calibration curves of dabigatran and rivaroxaban were linear over the working range between 0.8 and 800 μg/L (r >0.99. Limits of detection (LOD in the plasma matrix were 0.21 μg/L for dabigatran and 0.34 μg/L for rivaroxaban, and lower limits of quantification (LLOQ in the plasma matrix were 0.46 μg/L for dabigatran and 0.54 μg/L for rivaroxaban. The intraassay coefficients of variation (CVs for dabigatran and rivaroxaban were < 4% and 6%; respectively, the interassay CVs were < 6% for dabigatran and < 9% for rivaroxaban. Inaccuracy was < 5% for both substances. The mean recovery was 104.5% (range 83.8-113.0% for dabigatran and 87.0% (range 73.6-105.4% for rivaroxaban. No significant ion suppressions were detected at the elution times of dabigatran or rivaroxaban. Both coagulation inhibitors were stable in citrate plasma at -20°C, 4°C and even at RT for at

  8. Irradiation influence on Mylar and Makrofol induced by argon ions in a plasma immersion ion implantation system

    Science.gov (United States)

    Hassan, A.; El-Saftawy, A. A.; Aal, S. A. Abd El; Ghazaly, M. El

    2015-08-01

    Mylar and Makrofol polycarbonate polymers were irradiated by Ar ions in a plasma immersion ion implantation (PIII) system. The surface wettability of both polymers was investigated by employing the contact angle method. The measured contact angles were found to depend on the surface layer properties. Good wetting surfaces were found to depend not only on surface roughness but also on its chemistry that analyzed by Fourier transform infrared (FTIR) spectroscopy. Surfaces topography and roughness was investigated and correlated to their surface energy which studied with the aid of acid-base model for evaluating the improvement of surface wettability after irradiation. PIII improves polymers surface properties efficiently in a controllable way.

  9. Development and Characterization of a 9-mm Inductively Coupled Argon Plasma (ICP) Source for Atomic Emission Spectrometry.

    Science.gov (United States)

    1980-09-30

    not be achieved. Allemand et al. (10) have reported the development and characterization of both 13-mm and 9-mm ICP torches. The 13-mm ICP performed...study, a new 9-mm torch is reported which supports a plasma at approximately 1/3 the r.f. power and less than half the Ar flow of a conve:tional...Alli;mid, IP.M4. Farn s and C.C. Wohlers , Anal. Chem., 51, 2392 (1i99). 11. S. c:-iti. 1 I.i iJ Specc 1(-him. Acta, Part It, 34, 423 P19.)’. 12. C.P

  10. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu.

    Directory of Open Access Journals (Sweden)

    Hidefumi Uchiyama

    Full Text Available Electron paramagnetic resonance (EPR-spin trapping and flow cytometry were used to identify free radicals generated using argon-cold atmospheric plasma (Ar-CAP in aqueous solutions and intracellularly in comparison with those generated by X-irradiation. Ar-CAP was generated using a high-voltage power supply unit with low-frequency excitation. The characteristics of Ar-CAP were estimated by vacuum UV absorption and emission spectra measurements. Hydroxyl (·OH radicals and hydrogen (H atoms in aqueous solutions were identified with the spin traps 5,5-dimethyl-1-pyrroline N-oxide (DMPO, 3,3,5,5-tetramethyl-1-pyrroline-N-oxide (M4PO, and phenyl N-t-butylnitrone (PBN. The occurrence of Ar-CAP-induced pyrolysis was evaluated using the spin trap 3,5-dibromo-4-nitrosobenzene sulfonate (DBNBS in aqueous solutions of DNA constituents, sodium acetate, and L-alanine. Human lymphoma U937 cells were used to study intracellular oxidative stress using five fluorescent probes with different affinities to a number of reactive species. The analysis and quantification of EPR spectra revealed the formation of enormous amounts of ·OH radicals using Ar-CAP compared with that by X-irradiation. Very small amounts of H atoms were detected whereas nitric oxide was not found. The formation of ·OH radicals depended on the type of rare gas used and the yield correlated inversely with ionization energy in the order of krypton > argon = neon > helium. No pyrolysis radicals were detected in aqueous solutions exposed to Ar-CAP. Intracellularly, ·OH, H2O2, which is the recombination product of ·OH, and OCl- were the most likely formed reactive oxygen species after exposure to Ar-CAP. Intracellularly, there was no practical evidence for the formation of NO whereas very small amounts of superoxides were formed. Despite the superiority of Ar-CAP in forming ·OH radicals, the exposure to X-rays proved more lethal. The mechanism of free radical formation in aqueous solutions and

  11. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu.

    Science.gov (United States)

    Uchiyama, Hidefumi; Zhao, Qing-Li; Hassan, Mariame Ali; Andocs, Gabor; Nojima, Nobuyuki; Takeda, Keigo; Ishikawa, Kenji; Hori, Masaru; Kondo, Takashi

    2015-01-01

    Electron paramagnetic resonance (EPR)-spin trapping and flow cytometry were used to identify free radicals generated using argon-cold atmospheric plasma (Ar-CAP) in aqueous solutions and intracellularly in comparison with those generated by X-irradiation. Ar-CAP was generated using a high-voltage power supply unit with low-frequency excitation. The characteristics of Ar-CAP were estimated by vacuum UV absorption and emission spectra measurements. Hydroxyl (·OH) radicals and hydrogen (H) atoms in aqueous solutions were identified with the spin traps 5,5-dimethyl-1-pyrroline N-oxide (DMPO), 3,3,5,5-tetramethyl-1-pyrroline-N-oxide (M4PO), and phenyl N-t-butylnitrone (PBN). The occurrence of Ar-CAP-induced pyrolysis was evaluated using the spin trap 3,5-dibromo-4-nitrosobenzene sulfonate (DBNBS) in aqueous solutions of DNA constituents, sodium acetate, and L-alanine. Human lymphoma U937 cells were used to study intracellular oxidative stress using five fluorescent probes with different affinities to a number of reactive species. The analysis and quantification of EPR spectra revealed the formation of enormous amounts of ·OH radicals using Ar-CAP compared with that by X-irradiation. Very small amounts of H atoms were detected whereas nitric oxide was not found. The formation of ·OH radicals depended on the type of rare gas used and the yield correlated inversely with ionization energy in the order of krypton > argon = neon > helium. No pyrolysis radicals were detected in aqueous solutions exposed to Ar-CAP. Intracellularly, ·OH, H2O2, which is the recombination product of ·OH, and OCl- were the most likely formed reactive oxygen species after exposure to Ar-CAP. Intracellularly, there was no practical evidence for the formation of NO whereas very small amounts of superoxides were formed. Despite the superiority of Ar-CAP in forming ·OH radicals, the exposure to X-rays proved more lethal. The mechanism of free radical formation in aqueous solutions and an

  12. 大气压氩等离子体射流特性%Characteristics of the Atmospheric Pressure Argon Plasma Jet

    Institute of Scientific and Technical Information of China (English)

    杨安; 聂秋月; 王志斌; 李和平; 张西正; 包成玉

    2012-01-01

    Abstract: In order to produce uniform, steady and large volume dielectric barrier discharge (DBD) argon plasma jets at atmospheric pressure, a plasma generator with a screw-like inner electrode configuration was proposed. A uni- form, steady and visibly glow-like discharge plasma jet was obtained at an open environment using this newly-de- signed plasma generator. The experimental and preliminary zero- dimensional modeling results show that, the dis- charges can be operated at an initial, transitional, stable or unstable discharge modes with the increase of the applied voltage; the glow-like discharge can occupy the whole glass tube with an inner-diameter of 8.9 mm at a stable dis- charge mode; the optical emission spectrum shows that there are different kinds of chemically reactive species in the plasma jet region; the estimated length of the plasma jet (longer than 30 mml based on the modeling and experi- ments are consistent with each other qualitatively. The axial profile of the emission intensity of the plasma jet is re- lated with the de-excitation process of the metastables in the plasma jet region.%为了在大气压下获得均匀、稳定且具有较大体积的氩气介质阻挡放电等离子体射流,提出了一种新的同轴型具有螺纹型内电极结构的等离子体发生器结构设计,在大气压开放环境下获得了均匀稳定的类辉光氩气介质阻挡放电等离子体射流。实验和初步的零维数值模拟结果表明:在所研究的工作参数范围内,放电随外加电压的增加可工作于初始放电阶段、过渡阶段、稳定放电和不稳定放电阶段;在稳定放电模式下,均匀弥散的类辉光放电可充满内径为8.9mm的玻璃管,发射光谱测量结果表明在等离子体射流区含有多种化学活性粒子;数值计算和实验测量所估算的等离子体射流长度基本一致(可为30mm以上),且等离子体射流发射光谱强度的轴向分布与其

  13. Use of a nitrogen-argon plasma to improve adherence of sputtered titanium carbide coatings on steel

    Science.gov (United States)

    Brainard, W. A.; Wheeler, D. R.

    1979-01-01

    Friction and wear experiments on 440-C steel surfaces that had been RF-sputtered with titanium carbide when a small percentage of nitrogen was added to the plasma were conducted. X-ray photoelectron spectroscopy and X-ray diffraction were used to analyze the resultant coatings. Results indicate that a small partial pressure of nitrogen (about 0.5%) markedly improves the adherence, friction, and wear properties when compared with coatings applied on sputter-etched oxidized surfaces or in the presence of a small oxygen partial pressure. The improvements are related to the formation of an interface containing a mixture of the nitrides of titanium and iron, which are harder than their corresponding oxides.

  14. Impact of cold atmospheric pressure argon plasma on antibiotic sensitivity of methicillin-resistant Staphylococcus aureus strains in vitro.

    Science.gov (United States)

    Lührmann, Anne; Matthes, Rutger; Kramer, Axel

    2016-01-01

    Zielsetzung: Die antimikrobielle Wirksamkeit von kaltem Atmosphärendruckplasma (CAP), auch als gewebeverträgliches Plasma (TTP) bezeichnet, könnte eine aussichtsreiche Option zur Eradikation von Methicillin-empfindlichen ebenso wie von Methicillin-resistenten Staphylococcus aureus-Stämmen sein, die oft chronische Wunden kolonisieren. Bisher wurde der Einfluss von CAP auf die Antibiotikaempfindlichkeit von S. aureus kaum untersucht. Da eine Veränderung der Antibiotikaempfindlichkeit für die Wundbehandlung relevant sein könnte, sollte der Einfluss von CAP auf die Empfindlichkeit verschiedener S. aureus-Stämme gegen unterschiedliche Antibiotika untersucht werden.Methode: Im Agardiffusionstest wurden Antibiotikatestplättchen mit Cefuroxim, Gentamicin, Oxacillin, Vancomycin, Ciprofloxacin, Co-Trimoxazol, Clindamycin und Erythromycin eingesetzt. Die Teststämme wurden auf Agar ausplattiert und mit CAP exponiert, bevor die Testplättchen aufgelegt wurden. Nach 24 h Bebrütung wurden die Inhibitionszonen gemessen und statistisch auf Unterschiede geprüft.Ergebnisse: In den meisten Fällen war die Einfluss von CAP auf die Antibiotikaempfindlichkeit zu vernachlässigen. Für zwei Stämme wurde die Empfindlichkeit gegenüber β-Lactam-Antibiotika signifikant herabgesetzt. Schlussfolgerung: Da CAP die Antibiotikaempfindlichkeit beeinflussen kann, sollten vor beabsichtigter kombinierter lokaler CAP-Behandlung und gleichzeitiger systemischer Antibiotikagabe Interaktionen in vitro untersucht werden, um unerwünschte Kombinationseffekte auszuschließen.

  15. Epistatic and pleiotropic effects of polymorphisms in the fibrinogen and coagulation factor XIII genes on plasma fibrinogen concentration, fibrin gel structure and risk of myocardial infarction.

    Science.gov (United States)

    Mannila, Maria Nastase; Eriksson, Per; Ericsson, Carl-Göran; Hamsten, Anders; Silveira, Angela

    2006-03-01

    An intricate interplay between the genes encoding fibrinogen gamma (FGG), alpha (FGA) and beta (FGB), coagulation factor XIII (F13A1) and interleukin 6 (IL6) and environmental factors is likely to influence plasma fibrinogen concentration, fibrin clot structure and risk of myocardial infarction (MI). In the present study, the potential contribution of SNPs harboured in the fibrinogen, IL6 and F13A1 genes to these biochemical and clinical phenotypes was examined. A database and biobank based on 387 survivors of a first MI and population-based controls were used. Sixty controls were selected according to FGG 9340T > C [rs1049636] genotype for studies on fibrin clot structure using the liquid permeation method. The multifactor dimensionality reduction method was used for interaction analyses. We here report that the FGA 2224G > A [rs2070011] SNP (9.2%), plasma fibrinogen concentration (13.1%) and age (8.1%) appeared as independent determinants of fibrin gel porosity. The FGA 2224G > A SNP modulated the relation between plasma fibrinogen concentration and fibrin clot porosity. The FGG-FGA*4 haplotype, composed of the minor FGG 9340C and FGA 2224A alleles, had similar effects, supporting its reported protective role in relation to MI. Significant epistasis on plasma fibrinogen concentration was detected between the FGA 2224G > A and F13A1 Val34Leu [rs5985] SNPs (p FGG 9340T > C and FGB 1038G > A [rs1800791] SNPs appeared to interact on MI risk, explaining the association of FGG-FGB haplotypes with MI in the absence of effects of individual SNPs. Thus, epistatic and pleiotropic effects of polymorphisms contribute to the variation in plasma fibrinogen concentration, fibrin clot structure and risk of MI.

  16. Experimental and Theoretical Estimation of Excited Species Generation in Pulsed Electron Beam-Generated Plasmas Produced in Pure Argon, Nitrogen, Oxygen, and Their Mixtures

    Science.gov (United States)

    2011-05-13

    cross sections were used and they are shown in the appendix. It should be noted that Bretagne et al.17 modeled electrons beams in argon using an...811 nm and 750 nm lines respectively based on data by Bretagne , Hayashi, Phelps, and Boffard. d) Theoretical results Results from two sets of...discussed above. Bretagne et al. used the continuous-slowing-down approximation to model beams in argon. This approach is less accurate than the Monte

  17. Effects of nitrogen on the apoptosis of and changes in gene expression in human lymphoma U937 cells exposed to argon-based cold atmospheric pressure plasma.

    Science.gov (United States)

    Tabuchi, Yoshiaki; Uchiyama, Hidefumi; Zhao, Qing-Li; Yunoki, Tatsuya; Andocs, Gabor; Nojima, Nobuyuki; Takeda, Keigo; Ishikawa, Kenji; Hori, Masaru; Kondo, Takashi

    2016-06-01

    Cold atmospheric pressure plasma (CAP) is known as a source of biologically active agents, such as reactive oxygen species (ROS) and reactive nitrogen species (RNS). In the present study, we examined the effects of nitrogen (N2) on the apoptosis of and changes in gene expression in human lymphoma U937 cells exposed to argon (Ar)-CAP. Enormous amounts of hydroxyl (·OH) radicals in aqueous solution were produced using Ar‑CAP generated using a 20 kHz low frequency at 18 kV with a flow rate of 2 l/min. The increase in the levels of ·OH radicals was significantly attenuated by the addition of N2 to Ar gas. On the other hand, the level of total nitrate/nitrite in the supernatant was significantly elevated in the Ar + N2-CAP‑exposed U937 cells. When the cells were exposed to Ar‑CAP, a significant increase in apoptosis was observed, whereas apoptosis was markedly decreased in the cells exposed to Ar + N2-CAP. Microarray and pathway analyses revealed that a newly identified gene network containing a number of heat shock proteins (HSPs), anti-apoptotic genes, was mainly associated with the biological function of the prevention of apoptosis. Quantitative PCR revealed that the expression levels of HSPs were significantly elevated in the cells exposed to Ar + N2-CAP than those exposed to Ar‑CAP. These results indicate that N2 gas in Ar‑CAP modifies the ratio of ROS to RNS, and suppresses the apoptosis induced by Ar‑CAP. The modulation of gaseous conditions in CAP may thus prove to be useful for future clinical applications, such as for switching from a sterilizing mode to cytocidal effect for cancer cells.

  18. Nanocrystalline silicon and silicon quantum dots formation within amorphous silicon carbide by plasma enhanced chemical vapour deposition method controlling the Argon dilution of the process gases

    Energy Technology Data Exchange (ETDEWEB)

    Kole, Arindam; Chaudhuri, Partha, E-mail: erpc@iacs.res.in

    2012-11-01

    Structural and optical properties of the amorphous silicon carbide (a-SiC:H) thin films deposited by radio frequency plasma enhanced chemical vapour deposition method from a mixture of silane (SiH{sub 4}) and methane (CH{sub 4}) diluted in argon (Ar) have been studied with variation of Ar dilution from 94% to 98.4%. It is observed that nanocrystalline silicon starts to form within the a-SiC:H matrix by increasing the dilution to 96%. With further increase in Ar dilution to 98% formation of the silicon nanocrystals (nc-Si) with variable size is enhanced. The optical band gap (E{sub g}) of the a-SiC:H film decreases from 2.0 eV to 1.9 eV with increase in Ar dilution from 96% to 98% as the a-SiC:H films gradually become Si rich. On increasing the Ar dilution further to 98.4% leads to the appearance of crystalline silicon quantum dots (c-Si q-dots) of nearly uniform size of 3.5 nm. The quantum confinement effect is apparent from the sharp increase in the E{sub g} value to 2.6 eV. The phase transformation phenomenon from nc-Si within the a-SiC:H films to Si q-dot were further studied by high resolution transmission electron microscopy and the grazing angle X-ray diffraction spectra. A relaxation in the lattice strain has been observed with the formation of Si q-dots.

  19. Interaction of nanosecond ultraviolet laser pulses with reactive dusty plasma

    Science.gov (United States)

    van de Wetering, F. M. J. H.; Oosterbeek, W.; Beckers, J.; Nijdam, S.; Gibert, T.; Mikikian, M.; Rabat, H.; Kovačević, E.; Berndt, J.

    2016-05-01

    Even though UV laser pulses that irradiate a gas discharge are small compared to the plasma volume (≲3%) and plasma-on time (≲6 × 10-6%), they are found to dramatically change the discharge characteristics on a global scale. The reactive argon-acetylene plasma allows the growth of nanoparticles with diameters up to 1 μm, which are formed inside the discharge volume due to spontaneous polymerization reactions. It is found that the laser pulses predominantly accelerate and enhance the coagulation phase and are able to suppress the formation of a dust void.

  20. Polymorphisms of the coagulation factor Ⅶ gene and its plasma levels in relation to acute cerebral infarction differences in allelic frequencies between Chinese Han and European populations

    Institute of Scientific and Technical Information of China (English)

    康文英; 王鸿利; 熊立凡; 王学锋; 储海燕; 璩斌; 刘湘帆; 尹俊; 段宝华; 王振义

    2004-01-01

    Background Coagulation factor Ⅶ (F Ⅶ) levels in plasma are usually related to ischemic heart disease (IHD) and cerebral infarction shares many of the risk factors related to IHD. Is there any relationship between factor Ⅶ and cerebral infarction? We investigated the relationship between F Ⅶ and acute cerebral infarction and reported genotype frequencies and allelic frequencies of FⅦ gene polymorphisms in the Chinese Han population.Methods We recruited 62 patients with acute cerebral infarction confirmed by magnetic resonance imaging (MRI) from Ruijin Hospital, and 149 age-matched patients clinically free of vascular disease to act as controls. All of them were unrelated, and were from the Chinese Han population. FⅦ coagulant activity (FⅦc) was determined using an clotting assay, activated FⅦ (FⅦa) and FⅦ Ag were assayed using enzyme immunoassay kits. The FⅦ gene polymorphisms to be detected included-401G/T, -402G/A, 5'F7A1/A2, IVS7 and R353Q. 5'F7 and IVS7 were revealed by means of a PCR and direct agarose gel electrophoresis. The rest were examined by a polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Results The results showed that FⅦc, FⅦAg and FⅦa were higher in the acute cerebral infarction group than in the control group (P<0.01, P<0.05, P<0.05, respectively). There were no significant differences in the genotype frequencies of FⅦ gene polymorphisms between the two groups. The allelic frequencies in the Chinese Han population were as follows: -401G/T (96.64/3.36), -402G/A (52.01/47.99), 5'F7A1/A2(96.64/3.36), IVS7 H5/H6/H7/H8 (0.34/52.35/46.98/0.34) and R353Q (95.64/4.36). There were significant differences (P<0.01, P<0.001, P<0.001, P<0.001, P<0.001, respectively) in these allelic frequencies between the Chinese Han and European populations.Conclusions The results indicate that increased plasma FⅦ levels may contribute to thrombosis in cerebral infarction. And there was no significant difference

  1. First principles transport coefficients and reaction rates of Ar{sub 2}{sup +} ions in argon for cold plasma jet modeling

    Energy Technology Data Exchange (ETDEWEB)

    Chicheportiche, Alexandre; Benhenni, Malika; Yousfi, Mohammed, E-mail: yousfi@laplace.univ-tlse.fr [Laboratoire Plasma et Conversion d’Energie, LAPLACE and UMR5213 du CNRS, Université de Toulouse, UPS, 118 route de Narbonne, 31062 Toulouse Cedex (France); Stachoň, Martin; Kalus, René, E-mail: rene.kalus@vsb.cz [Center of Excellence IT4Innovations and Department of Applied Mathematics, VSB - Technical University of Ostrava, 17. listopadu 15, 708 33 Ostrava (Czech Republic); Gadéa, Florent Xavier [Laboratoire de Chimie et de Physique Quantiques, IRSAMC and UMR5626 du CNRS, Université de Toulouse, UPS, 118 route de Narbonne, 31062 Toulouse Cedex (France)

    2014-10-07

    Momentum-transfer collision cross-sections and integral collision cross-sections for the collision-induced dissociation are calculated for collisions of ionized argon dimers with argon atoms using a nonadiabatic semiclassical method with the electronic Hamiltonian calculated on the fly via a diatomics-in-molecules semiempirical model as well as inverse-method modeling based on simple isotropic rigid-core potential. The collision cross-sections are then used in an optimized Monte Carlo code for evaluations of the Ar{sub 2}{sup +} mobility in argon gas, longitudinal diffusion coefficient, and collision-induced dissociation rates. A thorough comparison of various theoretical calculations as well as with available experimental data on the Ar{sub 2}{sup +} mobility and collision cross-sections is performed. Good agreement is found between both theoretical approaches and the experiment. Analysis of the role of inelastic processes in Ar{sub 2}{sup +}/Ar collisions is also provided.

  2. Spatial coagulation with bounded coagulation rate

    OpenAIRE

    Bailleul, Ismael

    2010-01-01

    We prove that the spatial coagulation equation with bounded coagulation rate is well-posed for all times in a given class of kernels if the convection term of the underlying particle dynamics has divergence bounded below by a positive constant. Multiple coagulations, fragmentation and scattering are also considered.

  3. Potentiation of thrombin generation in hemophilia A plasma by coagulation factor VIII and characterization of antibody-specific inhibition.

    Directory of Open Access Journals (Sweden)

    Bhavya S Doshi

    Full Text Available Development of inhibitory antibodies to coagulation factor VIII (fVIII is the primary obstacle to the treatment of hemophilia A in the developed world. This adverse reaction occurs in 20-30% of persons with severe hemophilia A treated with fVIII-replacement products and is characterized by the development of a humoral and neutralizing immune response to fVIII. Patients with inhibitory anti-fVIII antibodies are treated with bypassing agents including recombinant factor VIIa (rfVIIa. However, some patients display poor hemostatic response to bypass therapy and improved treatment options are needed. Recently, we demonstrated that fVIII inhibitors display widely variable kinetics of inhibition that correlate with their respective target epitopes. Thus, it was hypothesized that for antibodies that display slow rates of inhibition, supplementation of rfVIIa with fVIII would result in improved thrombin generation and be predictive of clinical responses to this novel treatment regimen. In order to test this hypothesis, 10 murine monoclonal antibodies (MAbs with non-overlapping epitopes spanning fVIII, differential inhibition titers, and inhibition kinetics were studied using a thrombin generation assay. Of the 3 MAbs with high inhibitory titers, only the one with fast and complete (classically defined as "type I" kinetics displayed significant inhibition of thrombin generation with no improvement upon supplementation of rfVIIa with fVIII. The other two MAbs that displayed incomplete (classically defined as "type II" inhibition did not suppress the potentiation of thrombin generation by fVIII. All antibodies that did not completely inhibit fVIII activity demonstrated potentiation of thrombin generation by the addition of fVIII as compared to rfVIIa alone. In conclusion, fVIII alone or in combination with rfVIIa corrects the thrombin generation defect produced by the majority of anti-fVIII MAbs better than single agent rfVIIa. Therefore, combined f

  4. Relationship between disseminated intravascular coagu-lation and levels of plasma thrombinogen segment 1+2,D-dimer, and thrombomodulin in patients with multiple injuries

    Institute of Scientific and Technical Information of China (English)

    ZHU Yu-jun; HUANG Xian-kai

    2009-01-01

    Objective: To explore the relationship between dis-seminated intravascular coagulation (DIC) and levels of plasma thrombinogen segment 1+2 (F1+2), D-dimer (D-D), and thrombomodulin (TM) in patients with severe multiple injuries.Methods: In this study, 66 patients (49 males and 17 females, aged 15-74 years, mean=38.4 years) with multiple injuries, who were admitted to our hospital within 24 hours after injury with no personal or family history of hematopathy or coagulopathy, were divided into a minor injury group (ISS≥16, n=45) according to the injury severity. The patients in the major injury group were divided into a subgroup complicated with DIC (DIC subgroup, n=12) and a subgroup compli-cated with no DIC (non-DIC subgroup, n=33). Ten healthy people (7 males and 3 females, aged 22-61 years, mean=36.5 years±9.0 years), who received somatoscopy and diagnosed as healthy, served as the control group. Venous blood samples were collected once in the control group and 1, 3 and 7 days after trauma in the injury groups. The F1+2 and TM concentrations were determined by enzyme linked immunosorbent assay (ELISA), and D-D concentrations were measured by automated latex enhanced immunoassay. Results: F1+2, D-D and TM levels were higher in the minor and major injury groups than in the control group.They were markedly higher in the major injury group than in the minor injury group. In the non-DIC subgroup, F1+2 levels declined gradually while D-D and TM levels declined continuously. In the DIC subgroup, F1+2 and D-D levels remained elevated while TM levels exhibited an early rise and subsequent decrease. Plasma F1+2, D-D and TM levels were higher in the DIC patients than in the non-DIC patients. Injury-induced increases in F1+2, D-D and TM plasma lev-els had significant positive correlation with each other at each time point.Conclusions: Besides being related to trauma severity, F1+2, D-D and TM levels correlate closely with the occur-rence of posttraumatic DIC. Therefore

  5. Characterization of the gene for the a subunit of human factor XIII (plasma transglutaminase), a blood coagulation factor

    Energy Technology Data Exchange (ETDEWEB)

    Ichinose, A.; Davie, E.W. (Univ. of Washington, Seattle (USA))

    1988-08-01

    Factor XIII (plasma transglutaminase, fibrin stabilizing factor) is a glycoprotein that circulates in blood as a tetramer (a{sub 2}b{sub 2}) consisting of two a and two b subunits. The primary structures of the a and b subunits of human factor XIII have been reported by a combination of cDNA cloning and amino acid sequence analysis. To establish the gene structure of the a subunit for factor XIII, several human genomic libraries were screened by using the cDNA encoding the a subunit as a probe. Among {approx}5 {times} 10{sup 7} recombinant phage, 121 have been shown to contain an insert encoding a portion of the a subunit. Twenty-five unique clones were than characterized by restriction mapping, Southern blotting, and DNA sequencing. Overlapping clones encoding the a subunit of factor XIII span >160 kilobases. DNA sequence analysis revealed that the activation peptide released by thrombin, the active site cysteine region, the two putative calcium-binding regions, and the thrombin cleavage site leading to inactivation are encoded by separate exons. This suggest that the introns may separate the a subunit into functional and structural domains. A comparison of the amino acid sequence deduced from the genomic DNA sequence with those deduced from cDNA or determined by amino acid sequence analysis of the plasma and placental proteins revealed apparent amino acid polymorphisms in six positions of the polypeptide chain of the a subunit.

  6. Coagulation Factors Test

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Coagulation Factors Share this page: Was this page helpful? ... else I should know? How is it used? Coagulation factor testing is performed to determine if a ...

  7. Power Consideration for Pulsed Discharges in Potassium Seeded Argon

    Institute of Scientific and Technical Information of China (English)

    XIA Sheng-Guo; HE Jun-Jia; LIU Ke-Fu

    2007-01-01

    Minimization of energy consumed in plasma generation is critical for applications, in which a large volume of plasmas is needed. We suggest that a high electron density atmospheric pressure plasmas can be generated by pulsed discharges in potassium seeded argon at an elevated temperature with a very small power input. The ionization efficiency and power budget of pulsed discharges in such plasmas are analytically studied. The results show that ionization efficiency of argon, especially at small reduced electric field E/N (the ratio of the electric field to the gas number density), is improved effectively in the presence of small amount of potassium additives. Power input of pulsed discharge to sustain a prescribed average level of ionization in potassium seeded argon is three orders of magnitude lower than that in pure argon. Further, unlike in pure argon, it is found that very short high-voltage pulses with very high repetition rates are unnecessary in potassium seeded argon. A pulse with 100ns of pulse duration, 5kHz of repetition rate, and 2Td (1 Td = 1 ×10-21 Vm2) of E/N is enough to sustain an electron density of 10l9m-3 in 1 atm 1500 K Ar+0.1% K mixture, with a very small power input of about 0.08 × 104 W/m3.

  8. Treatment of Disseminated Intravascular Coagulation.

    Science.gov (United States)

    Makruasi, Nisa

    2015-11-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic activation of blood coagulation, generation of thrombin, and leading to disturbance of the microvasculature. In this article, definition and diagnostic criteria of DIC depend on the International Society of Thrombosis and Haemostasis (ISTH). There is no gold standard for diagnosis of DIC, only low quality evidence is used in general practice. Many diagnostic tests and repeated measurement are required. For the treatment of DIC, there is no good quality evidence. The most important treatment for DIC is the specific treatment of the conditions associated DIC. Platelets and/or plasma transfusion may be also necessary if indicated. Nevertheless, there is no gold standard for diagnosis and treatment of DIC, we use only low quality evidence in general practice.

  9. Disseminated intravascular coagulation in term and preterm neonates.

    Science.gov (United States)

    Veldman, Alex; Fischer, Doris; Nold, Marcel F; Wong, Flora Y

    2010-06-01

    Among critically ill patients, the risk of developing disseminated intravascular coagulation (DIC) is probably highest in neonates. Low plasma reserves in pro- and anticoagulant coagulation factors, intravascular volume contraction after birth, and a high incidence of hypoxia and sepsis in critically ill newborns rapidly lead to a decompensation of the coagulation system in this population. Global coagulation tests and single-factor plasma levels have to be interpreted in the context of age-corrected normal ranges. Platelet consumption and reduced protein C plasma levels have diagnostic value; the latter also has prognostic potential in neonates with DIC and sepsis. Therapeutic success relies heavily on reversal of the underlying condition. Some coagulation-specific therapies have been explored in small studies and case series with varying success and sometimes conflicting results. Therefore, larger controlled trials in this common and serious condition are urgently needed.

  10. Tissue gas and blood analyses of human subjects breathing 80% argon and 20% oxygen

    Science.gov (United States)

    Horrigan, D. J.; Wells, C. H.; Guest, M. M.; Hart, G. B.; Goodpasture, J. E.

    1979-01-01

    Eight human volunteers, individually studied in a hyperbaric chamber, breathed: (1) air at 1 ATA; (2) 80% argon and 20% oxygen at 1 ATA for 30 min; (3) air at 1 ATA for 30 min; (4) 100% O2 at 1 ATA for 30 min; (5) air at 1 ATA for 30 min; (6) 100% O2 at 2 ATA for 60 min; and (7) 80% argon and 20% oxygen at 1 ATA for 30 min. Oxygen, carbon dioxide, nitrogen, and argon tensions were measured in muscle and subcutaneous tissue by mass spectroscopic analyses. Venous blood obtained at regular intervals was analyzed for coagulation and fibrinolytic factors. Inert gas narcosis was not observed. After breathing argon for 30 min, muscle argon tensions were almost three times the subcutaneous tensions. Argon wash-in mirrored nitrogen wash-out. Argon wash-in and wash-out had no effect on tissue PO2 or PCO2. Coagulation and fibrinolytic changes usually associated with vascular bubbles were absent.

  11. Argon in action

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    Over the past few days, the SPS has been accelerating argon ions, which have started to be sent to the NA61/SHINE experiment. This operating mode, using a new type of ion, required a number of modifications to the accelerator.   Picture 1: a “super-cycle” of the SPS, featuring a proton cycle for the LHC, followed by an argon ion cycle for the North Area. Today, the accelerators are once again juggling particles and even performing completely new tricks. The SPS is supplying beams of argon ions for the first time, at energies never before achieved for this type of beam. They are destined for the NA61/SHINE experiment (see box) located in the North Area, which began receiving the beams on 11 February. Argon ions have a relatively large mass, as they consist of 40 nucleons, so they can be used in a similar way to lead ions. The main difficulty in accelerating them lies in the SPS, where the variation in acceleration frequency is limited. “The SPS was designed for a...

  12. Coagulation factor VIII activity in diabetic patients

    Directory of Open Access Journals (Sweden)

    Nermina Babić

    2011-02-01

    Full Text Available Aim To examine coagulation factor VIII activity in plasma, as a risk factor for thrombosis, in the patients with diabetes mellitus (DM. Also, to assess its relationship with ibrinogen and fasting blood glucose concentrations and with body mass index. Methods The plasma coagulation factor VIII activity, plasma levels of ibrinogen and blood glucose concentrations were measured in 30 patients with DM type 1, 30 patients with DM type 2 and in 30 healthy subjects. Body weight and body height were also measured and BMI was calculated.Results The plasma factor VIII activity in patients with DM type 1 and patients with DM type 2 was signiicantly higher than the values measured in healthy subjects. There was no signiicant difference in the factor VIII activity between patients with DM type 1 and type 2. The concentrations of ibrinogen and blood glucose in both groups of patients were signiicantly higher than in the group of healthy subjects. Patients with DM type 2 had a signiicantly higher BMI compared to healthy subjects, as well as compared to patients with DM type 1. There was a signiicant positive correlation between plasma factor VIII activity and plasma level of ibrinogen and a signiicant negative correlation between factor VIII activity and BMI in patients with DM type 2. Conclusion Diabetic patients have the elevated plasma coagulation factor VIII activity and increased ibrinogen concentration thus an increased risk of thrombosis and vascular diseases.

  13. Future liquid Argon detectors

    CERN Document Server

    Rubbia, A

    2013-01-01

    The Liquid Argon Time Projection Chamber offers an innovative technology for a new class of massive detectors for rare-event detection. It is a precise tracking device that allows three-dimensional spatial reconstruction with mm-scale precision of the morphology of ionizing tracks with the imaging quality of a "bubble chamber", provides $dE/dx$ information with high sampling rate, and acts as high-resolution calorimeter for contained events. First proposed in 1977 and after a long maturing process, its holds today the potentialities of opening new physics opportunities by providing excellent tracking and calorimetry performance at the relevant multi-kton mass scales, outperforming other techniques. In this paper, we review future liquid argon detectors presently being discussed by the neutrino physics community.

  14. Direct solid analysis of powdered tungsten carbide hardmetal precursors by laser-induced argon spark ablation with inductively coupled plasma atomic emission spectrometry.

    Science.gov (United States)

    Holá, Markéta; Kanický, Viktor; Mermet, Jean-Michel; Otruba, Vítezslav

    2003-12-01

    The potential of the laser-induced argon spark atomizer (LINA-Spark atomizer) coupled with ICP-AES as a convenient device for direct analysis of WC/Co powdered precursors of sintered hardmetals was studied. The samples were presented for the ablation as pressed pellets prepared by mixing with powdered silver binder containing GeO2 as internal standard. The pellets were ablated with the aid of a Q-switched Nd:YAG laser (1064 nm) focused 16 mm behind the target surface with a resulting estimated power density of 5 GW cm(-2). Laser ablation ICP-AES signals were studied as a function of ablation time, and the duration of time prior to measurement (pre-ablation time) which was necessary to obtain reliable results was about 40 s. Linear calibration plots were obtained up to 10% (m/m) Ti, 9% Ta and 3.5% Nb both without internal standardization and by using germanium as an added internal standard or tungsten as a contained internal standard. The relative uncertainty at the centroid of the calibration line was in the range from +/- 6% to +/- 11% for Nb, Ta and Ti both with and without internal standardisation by Ge. A higher spread of points about the regression was observed for cobalt for which the relative uncertainty at the centroid was in the range from +/- 9% to +/- 14%. Repeatability of results was improved by the use of both Ge and W internal standards. The lowest determinable quantities calculated for calibration plots were 0.060% Co, 0.010% Nb, 0.16% Ta and 0.030% Ti with internal standardization by Ge. The LA-ICP-AES analyses of real samples led to good agreement with the results obtained by solution-based ICP determination with a relative bias not exceeding 10%. The elimination of the dissolution procedure of powdered tungsten (Nb, Ta, Ti) carbide is the principal advantage of the developed LA-ICP-AES method.

  15. Microrheological Coagulation Assay Exploiting Micromechanical Resonators.

    Science.gov (United States)

    Padovani, Francesco; Duffy, James; Hegner, Martin

    2017-01-03

    Rheological measurements in biological liquids yield insights into homeostasis and provide information on important molecular processes that affect fluidity. We present a fully automated cantilever-based method for highly precise and sensitive measurements of microliter sample volumes of human blood plasma coagulation (0.009 cP for viscosity range 0.5-3 cP and 0.0012 g/cm(3) for density range 0.9-1.1 g/cm(3)). Microcantilever arrays are driven by a piezoelectric element, and resonance frequencies and quality factors of sensors that change over time are evaluated. A highly accurate approximation of the hydrodynamic function is introduced that correlates resonance frequency and quality factor of cantilever beams immersed in a fluid to the viscosity and density of that fluid. The theoretical model was validated using glycerol reference solutions. We present a surface functionalization protocol that allows minimization of unspecific protein adsorption onto cantilevers. Adsorption leads to measurement distortions and incorrect estimation of the fluid parameters (viscosity and density). Two hydrophilic terminated self-assembled monolayers (SAMs) sensor surfaces are compared to a hydrophobic terminated SAM coating. As expected, the hydrophobic modified surfaces induced the highest mass adsorption and could promote conformational changes of the proteins and subsequent abnormal biological activity. Finally, the activated partial thromboplastin time (aPTT) coagulation assay was performed, and the viscosity, density, and coagulation rate of human blood plasma were measured along with the standard coagulation time. The method could extend and improve current coagulation testing.

  16. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    Science.gov (United States)

    Sun, Wen-Ting; Li, Guo; Li, He-Ping; Bao, Cheng-Yu; Wang, Hua-Bo; Zeng, Shi; Gao, Xing; Luo, Hui-Ying

    2007-06-01

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images.

  17. 大气压氩气射流等离子体的光谱特性研究%Investigation on the Spectral Characteristics of a Plasma Jet in Atmospheric Argon Glow Discharge

    Institute of Scientific and Technical Information of China (English)

    李雪辰; 张春艳; 李霁媛; 鲍文婷

    2015-01-01

    等离子体喷枪是一种重要的等离子体源,已成为近几年低温等离子体研究的一个重要课题。本文利用钨针-钨丝网电极制作了直流喷枪装置,在大气压空气中产生了稳定的等离子体羽,并采用发射光谱的方法,对等离子体羽的等离子体参数进行了研究。在钨针电极与钨丝网电极之间放出耀眼的白光,钨丝网电极出口的气流下游有火苗形状的等离子体羽喷出。在电压保持不变的条件下(13.5 kV),等离子体羽长度随气体流量增加而增大;在气体流量保持不变的条件下(10 L・min-1),羽长度随外加电压的增大而增大。在气体流量一定的条件下,放电电压和放电电流呈反比例关系,即电压随着电流的增大而减小,说明放电属于辉光放电。采集了该喷枪在300~800 nm范围内的放电发射光谱,通过玻尔兹曼方法对放电等离子体电子激发温度进行了测量。结果表明,电子的激发温度随外加电压的增大而降低,随着工作气体流量的减小而升高。利用放电的基本理论对上述现象做了解释。这些研究结果对大气压均匀放电等离子体源的研制和工业应用具有重要意义。%Plasma jet is a kind of important plasma source at atmospheric pressure .In recent years ,it becomes an important hot topic in the field of low temperature plasma .In this paper ,using a tungsten needle and a tungsten wire mesh ,a direct-current excited jet is developed to operate in argon at atmospheric pressure .In the atmospheric pressure argon ,the plasma jet can pro-duce a stable plasma plume .By using the method of emission spectroscopy ,the parameters of the plasma plume are investigated . The discharge emits dazzling white light from the area between the tungsten needle electrode and the wire mesh electrode .A plasma plume with a flame shape appears outside the tungsten wire mesh electrode .For a constant value of

  18. Effect of oxygen atoms dissociated by non-equilibrium plasma on flame of methane oxygen and argon pre-mixture gas

    Science.gov (United States)

    Akashi, Haruaki; Yoshinaga, Tomokazu; Sasaki, Koichi

    2014-10-01

    For more efficient way of combustion, plasma-assisted combustion has been investigated by many researchers. But it is very difficult to clarify the effect of plasma even on the flame of methane. Because there are many complex chemical reactions in combustion system. Sasaki et al. has reported that the flame length of methane and air premixed burner shortened by irradiating microwave power. They also measured emission from Second Positive Band System of nitrogen during the irradiation. The emission indicates existence of high energy electrons which are accelerated by the microwave. The high energy electrons also dissociate oxygen molecules easily and oxygen atom would have some effects on the flame. But the dissociation ratio of oxygen molecules by the non-equilibrium plasma is significantly low, compared to that in the combustion reaction. To clarify the effect of dissociated oxygen atoms on the flame, dependence of dissociation ratio of oxygen on the flame has been examined using CHEMKIN. It is found that in the case of low dissociation ratio of 10-6, the ignition of the flame becomes slightly earlier. It is also found that in the case of high dissociation ratio of 10-3, the ignition time becomes significantly earlier by almost half. This work was supported by KAKENHI (22340170).

  19. Plasma Sources for Medical Applications - A Comparison of Spot Like Plasmas and Large Area Plasmas

    Science.gov (United States)

    Weltmann, Klaus-Dieter

    2015-09-01

    Plasma applications in life science are currently emerging worldwide. Whereas today's commercially available plasma surgical technologies such as argon plasma coagulation (APC) or ablation are mainly based on lethal plasma effects on living systems, the newly emerging therapeutic applications will be based on selective, at least partially non-lethal, possibly stimulating plasma effects on living cells and tissue. Promising results could be obtained by different research groups worldwide revealing a huge potential for the application of low temperature atmospheric pressure plasma in fields such as tissue engineering, healing of chronic wounds, treatment of skin diseases, tumor treatment based on specific induction of apoptotic processes, inhibition of biofilm formation and direct action on biofilms or treatment of dental diseases. The development of suitable and reliable plasma sources for the different therapies requires an in-depth knowledge of their physics, chemistry and parameters. Therefore much basic research still needs to be conducted to minimize risk and to provide a scientific fundament for new plasma-based medical therapies. It is essential to perform a comprehensive assessment of physical and biological experiments to clarify minimum standards for plasma sources for applications in life science and for comparison of different sources. One result is the DIN-SPEC 91315, which is now open for further improvements. This contribution intends to give an overview on the status of commercial cold plasma sources as well as cold plasma sources still under development for medical use. It will discuss needs, prospects and approaches for the characterization of plasmas from different points of view. Regarding the manageability in everyday medical life, atmospheric pressure plasma jets (APPJ) and dielectric barrier discharges (DBD) are of special interest. A comprehensive risk-benefit assessment including the state of the art of commercial sources for medical use

  20. Study of nuclear recoils in liquid argon with monoenergetic neutrons

    CERN Document Server

    Regenfus, C; Amsler, C; Creus, W; Ferella, A; Rochet, J; Walter, M

    2012-01-01

    For the development of liquid argon dark matter detectors we assembled a setup in the laboratory to scatter neutrons on a small liquid argon target. The neutrons are produced mono-energetically (E_kin=2.45 MeV) by nuclear fusion in a deuterium plasma and are collimated onto a 3" liquid argon cell operating in single-phase mode (zero electric field). Organic liquid scintillators are used to tag scattered neutrons and to provide a time-of-flight measurement. The setup is designed to study light pulse shapes and scintillation yields from nuclear and electronic recoils as well as from {\\alpha}-particles at working points relevant to dark matter searches. Liquid argon offers the possibility to scrutinise scintillation yields in noble liquids with respect to the populations of the two fundamental excimer states. Here we present experimental methods and first results from recent data towards such studies.

  1. Effect of different time on coagulation factors in fresh frozen plasma after thawing%不同放置时间对融化后新鲜冰冻血浆中凝血因子的影响

    Institute of Scientific and Technical Information of China (English)

    徐会芹

    2015-01-01

    Objective To investigate the effect of different time on coagulation factors in fresh frozen plasma after thawing.Methods The medicine blood by ACD B anticoagulated whole blood separation, preparation and fresh frozen plasma30,37℃ water bath melting and melt after 0,6,12,24h determination of prothrombin time (PT),activated partial thromboplastin time(APTT),fibrinogen(FIB),thrombin time (TT),coagulation factor FⅦ、FⅧ、FⅨ activity level.ResultsAfter the fresh frozen plasma,the PT,APTT,FIB,TT at different time points of the test results were not statistically different in 24 hours(P>0.05).Coagulation factor FⅦ and FⅧ changed with time and significantly decreased with the passage of time attenuation and blood immediate difference was statistically significant(P<0.05). FIX only when 12 hours had decreased,again after 24 hours.ConclusionFresh frozen plasma should be infused immediately after thawing,so as to guarantee the biological activity of coagulation factor and guarantee the effect of treatment.%目的:探讨不同放置时间对融化后新鲜冰冻血浆中凝血因子的影响。方法选择本院血站经ACD-B抗凝全血分离制备而成的新鲜冰冻血浆30份,37℃水浴融化,于融化后0、6、12、24h测定凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)、纤维蛋白(FIB)、凝血酶时间(TT)、凝血因子FⅦ、FⅧ、FⅨ活性水平。结果新鲜冷冻血浆融化后,PT、APTT、FIB、TT在24h内不同时间点测定结果,差异无统计学意义( P>0.05)。凝血因子FⅦ及FⅧ随时间的改变而有明显的降低,随着时间的推移衰减,与抽血即刻比较差异有统计学意义(P<0.05)。而FⅨ仅在12h的时候有一过性的下降,24h后又恢复。结论新鲜冰冻血浆在融化后应该立即输注,以保证凝血因子生物学活性,进一步保证治疗的效果。

  2. Electrical and Optical Diagnostics of Plasma Jet Generated by Needle-plate Dielectric Barrier Discharge at Atmospheric Argon%大气压氩气针-板介质阻挡放电的光电诊断

    Institute of Scientific and Technical Information of China (English)

    尹增谦; 沈崇丰; 王永杰; 王慧娟

    2014-01-01

    An atmospheric argon plasma jet was obtained with a needle-plate dielectric barrier dis-charge system. The discharge gap was kept at 4 mm and the argon gas flow rate was 0. 5 L/min. A test capacitor and a test resistance were connected in series in the circuit, and the discharge current and the transport charge were measured simultaneously. The average discharge power in a period of the applied voltage was calculated by Lissajous figure. The plasma jet was investigated spatially by optical emission spectroscopy, and the electron density was estimated by Stark broadening of ArⅠ696. 54 nm. It is found that the discharge is asymmetric at different discharge phases, and more dis-charge current pulses are generated during the positive half cycle of the applied voltage. In addition, with the increasing of the applied voltage, the pulse number and the discharge power increase. Mo-reover, the plasma density is in an order of 1015 cm-3 . With the increasing of the distance from the needle tip, the electron density of the plasma jet decreases from 2. 94 × 1015 cm-3 to 2. 28 × 1015 cm-3 . The results show that the electric field plays an important role in the discharge current num-ber and the spatial distribution of the electron density.%利用针-板介质阻挡放电装置,在4 mm长的气隙中产生了大气压氩气射流等离子体。利用电学方法实现了对放电电流和电荷量的同时测量,并且对放电脉冲数和放电功率进行了研究;利用发射光谱法对放电等离子体进行了空间分辨测量,并根据ArⅠ696.54 nm的Stark展宽计算了等离子体的电子密度。结果发现:随着外加电压的增加,每个周期内的放电脉冲数增加,放电功率也增加。随着针头距离的增加,电子密度由2.94×1015 cm-3逐渐减小到2.28×1015 cm-3。实验结果表明:电场强度对放电脉冲数和电子密度的空间分布起重要作用。

  3. Nitrogen metastable (N2(A3 Σu + )) in a cold argon atmospheric pressure plasma jet: Shielding and gas composition

    Science.gov (United States)

    Iseni, Sylvain; Bruggeman, Peter J.; Weltmann, Klaus-Dieter; Reuter, Stephan

    2016-05-01

    N 2 ( A 3 Σu + ) metastable species are detected and measured in a non-equilibrium atmospheric pressure plasma jet by laser induced fluorescence. A shielding device is used to change the ambient conditions additionally to the feeding gas composition. Varying the amount of N2 and air admixed to the feeding gas as well as changing the shielding gas from N2 to air reveals that the highest N 2 ( A 3 Σu + ) is achieved in the case of air admixtures in spite of the enhanced collisional quenching due to the presence of O2. The reasons for these observations are discussed in detail.

  4. Dust coagulation in ISM

    Science.gov (United States)

    Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David

    1989-01-01

    Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.

  5. Cancer and blood coagulation.

    Science.gov (United States)

    Boccaccio, C; Medico, E

    2006-05-01

    In human patients, blood coagulation disorders often associate with cancer, even in its early stages. Recently, in vitro and in vivo experimental models have shown that oncogene expression, or inactivation of tumour suppressor genes, upregulate genes that control blood coagulation. These studies suggest that activation of blood clotting, leading to peritumoral fibrin deposition, is instrumental in cancer development. Fibrin can indeed build up a provisional matrix, supporting the invasive growth of neoplastic tissues and blood vessels. Interference with blood coagulation can thus be considered as part of a multifaceted therapeutic approach to cancer.

  6. Emission and absorption spectroscopy study of Ar excited states in 13.56 MHz argon plasma operating at sub-atmospheric to atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Li, L. [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium); Nikiforov, A., E-mail: anton.nikiforov@ugent.be [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium); Institute of Solution Chemistry of the Russian Academy of Science, Academicheskaya St., 1, Ivanovo, 153045 (Russian Federation); Britun, N. [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Universite de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Snyders, R. [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Universite de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Materia Nova Research Centre, Parc Initialis, B-7000 Mons (Belgium); Leys, C. [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium)

    2015-05-01

    The densities of metastable and resonant states of Ar atoms are measured in high pressure Ar radio frequency discharge. Resonant absorption spectroscopy for the case of a low pressure spectral lamp and high-pressure plasma absorption lines is implemented for this purpose. The necessary generalizations for the high-pressure resonant absorption method are given. Absolute density of Ar 1s levels obtained at different RF input power and operating pressures are of the order of 10{sup 11} cm{sup −3}, which is in a good agreement with those reported in the literature. The population distribution on the Ar 2p (excited) levels, obtained from the optical emission spectroscopy, reveals strong deviation from thermal equilibrium for these levels in the high-pressure case. The generation of the Ar excited states in the studied discharges is compared to the previously reported results. - Highlights: • Strong non-equilibrium distribution of Ar 2p levels is observed. • The absolute number density of non-radiative Ar 1s states is determined by the easier and low cost spectral-lamp absorption method. • The modified absorption theory of Mitchell and Zemanski was used to obtain the absolute number density of Ar 1s states at high pressure. • The developed RF source with 5 cm long gap can be a possible alternative to micro-plasma working in Ar at atmospheric pressure.

  7. Numerical Modeling of Plasmas in which Nanoparticles Nucleate and Grow

    Science.gov (United States)

    Agarwal, Pulkit

    Dusty plasmas refer to a broad category of plasmas. Plasmas such as argon-silane plasmas in which particles nucleate and grow are widely used in semiconductor processing and nanoparticle manufacturing. In such dusty plasmas, the plasma and the dust particles are strongly coupled to each other. This means that the presence of dust particles significantly affects the plasma properties and vice versa. Therefore such plasmas are highly complex and they involve several interesting phenomena like nucleation, growth, coagulation, charging and transport. Dusty plasma afterglow is equally complex and important. Especially, residual charge on dust particles carries special significance in several industrial and laboratory situations and it has not been well understood. A 1D numerical model was developed of a low-pressure capacitively-coupled plasma in which nanoparticles nucleate and grow. Polydispersity of particle size distributions can be important in such plasmas. Sectional method, which is well known in aerosol literature, was used to model the evolving particle size and charge distribution. The numerical model is transient and one-dimensional and self consistently accounts for nucleation, growth, coagulation, charging and transport of dust particles and their effect on plasma properties. Nucleation and surface growth rates were treated as input parameters. Results were presented in terms of particle size and charge distribution with an emphasis on importance of polydispersity in particle growth and dynamics. Results of numerical model were compared with experimental measurements of light scattering and light emission from plasma. Reasonable qualitative agreement was found with some discrepancies. Pulsed dusty plasma can be important for controlling particle production and/or unwanted particle deposition. In this case, it is important to understand the behavior of the particle cloud during the afterglow following plasma turn-off. Numerical model was modified to self

  8. Modeling of particle coagulation in low pressure PECVD

    Science.gov (United States)

    Bhandarkar, U.; Kortshagen, U.

    1998-10-01

    Contaminant particles generated in plasmas used to manufacture semiconductor devices can potentially destroy micro-electronic circuits. Particles of micrometer-size in a plasma are usually negatively charged due to the higher mobility of electrons. Like charges on the particles should inhibit growth by coagulation. However, the coagulation rates of nanometer-sized particles observed experimentally are even higher than the thermal coagulation rates of uncharged particles. This observation implies the presence of positively charged nano-particles along with the negative ones such that the mutual attraction enhances coagulation. We propose photo-detachment of electrons due to UV radiation as a potential path for the generation of positively charged particles. We have developed a self-consistent plasma-coagulation model based on the General Dynamic Equation which is well-known from aerosol research. Plasma properties are determined self-consistently using a global plasma model. The particle charge distribution is calculated using a charging module which also accounts for UV photo-detachment. Preliminary results of this model yield coagulation rates consistent with those observed experimentally.

  9. Viscoelastic coagulation testing: technology, applications, and limitations.

    Science.gov (United States)

    McMichael, Maureen A; Smith, Stephanie A

    2011-06-01

    Use of viscoelastic point-of-care (POC) coagulation instrumentation is relatively new to veterinary medicine. In human medicine, this technology has recently undergone resurgence owing to its capacity to detect hypercoagulability. The lack of sensitive tests for detecting hypercoagulable states, along with our current understanding of in vivo coagulation, highlights the deficiencies of standard coagulation tests, such as prothrombin and partial thromboplastin times, which are performed on platelet-poor plasma. Viscoelastic coagulation analyzers can provide an assessment of global coagulation, from the beginning of clot formation to fibrinolysis, utilizing whole blood. In people, use of this technology has been reported to improve management of hemostasis during surgery and decrease usage of blood products and is being used as a rapid screen for hypercoagulability. In veterinary medicine, clinical use of viscoelastic technology has been reported in dogs, cats, foals, and adult horses. This article will provide an overview of the technology, reagents and assays, applications in human and veterinary medicine, and limitations of the 3 viscoelastic POC analyzers in clinical use.

  10. The Characteristic Research of ・OH Induced by Water on an Argon Plasma Jet%氩气等离子体射流诱导水生成OH自由基的研究

    Institute of Scientific and Technical Information of China (English)

    刘坤; 廖华; 郑培超; 王琛颖; 刘红弟; Dobrynin Danil

    2015-01-01

    ・OH plays a crucial role in many fields ,having aroused wide public concern in the world .Atmospheric Pressure Plasma Jet ,which can be achieved by portable device due to working without the vacuum environment ,has the advantages of high concentration of reactive species ,high electron temperature and low gas temperature .It has become an important research topic in the field of gas discharge with a strong prospect .Especially ,how to induce plasma jet to produce ・OH has become a new hotpot in the field of low‐temperature plasma .It has been reported that mass ・OH can be induced successfully when water vapor is added to the working gas ,but it will be unstable when the concentrate of water reaches a certain degree .Thus ,a device of argon plasma jet with a Ring‐to‐Ring Electrode Configuration has been designed to interact with water in the surrounding air to generate ・OH under atmospheric pressure .In order to increase the production of ・OH ,ultrasonic atomizing device is intro‐duced to promote water concentration around the plasma plume .The generating rule of OH (A2Σ+ ) induced by water has been extensively studied under different voltages and flow rate .・OH output induced by the plasma has been tested by emission spec‐trometry ,and at the meanwhile ,Ar atomic spectral lines at 810.41 and 811.48 nm are also recorded in order to calculate the electron temperature in argon plasma plume .The results show that the water surrounding the plasma plume can be induced to produce ・OH ,and OH(A2Σ+ ) output increases with the electrode voltage rising from 20 to 28 kV .When the flow rate increa‐ses from 100 to 200 L・h-1 ,the OH(A2Σ+ ) output increases ,but from 200 to 600 L・h-1 ,it decreases .The production rules of OH(A2Σ+ ) is the same as that of electron temperature .Therefore ,the presumption is proved that ・OH output mainly af‐fected by electron temperature .%・OH在众多领域中具有非常重要的作用,在国际上引起

  11. Estimation Using an Enhancement Factor on Non Local Thermodynamic Equilibrium Behavior of High-lying Energy Levels of Neutral Atom in Argon Radio-Frequency Inductively-Coupled Plasma.

    Science.gov (United States)

    Wagatsuma, Kazuaki; Satoh, Kozue

    2016-01-01

    This paper describes a plasma-diagnostic method using an enhancement factor on the Boltzmann distribution among emission lines of iron atom in an argon radio-frequency inductively-coupled plasma (ICP). It indicated that Boltzmann plots of the atomic lines having lower excitation energies (3.4 to 4.8 eV) were well fitted on a straight line while those having more than 5.5 eV deviated upwards from a linear relationship. This observation could be explained by the fact that ICP is not in a complete thermodynamic equilibrium between direct excitation to energy levels of iron atom, ionization of iron atom, and radiative decay processes to the ground state. Especially, the recombination of iron ion with captured electron should accompany cascade de-excitations between closely-spaced excited levels just below the ionization limit, the rates of which become slower as a whole; as a result, these high-lying levels might be more populated than the low-lying levels as if a different LTE condition coexists on the high energy side. This overpopulation could be quantitatively estimated using an enhancement factor (EF), which was a ratio of the observed intensity to the expected value extrapolated from the normal distribution on the low energy side. The EFs were generally small (less than 3); therefore, the cascade de-excitation process would slightly contribute to the population of these excited levels. It could be considered from variations of the EF that the overpopulation proceeded to a larger extent at lower radio-frequency forward powers, at higher flow rates of the carrier gas, or at higher observation heights. The reason for this is that the kinetic energy of energetic particles, such as electrons, becomes reduced under all of these plasma conditions, thus enabling the high-lying levels to be more populated by cascade de-excitation processes from iron ion rather than by collisional excitation processes with the energetic particles. A similar Boltzmann analysis using the EF

  12. Change in blood coagulation indices as a function of the incubation period of plasma in a constant magnetic field. [considering heparin tolerance and recalcification

    Science.gov (United States)

    Yepishina, S. G.

    1974-01-01

    The influence of a constant magnetic field (CMF) with a strength of 250 and 2500 oersteds on the recalcification reaction and the tolerance of plasma to heparin was studied as a function of the exposure time of the plasma to the CMF. The maximum and reliable change in the activation of the coagulatory system of the blood was observed after a 20-hour incubation of the plasma in a CMF. As the exposure time increased, the recalcification reaction changed insigificantly; the difference between the mean arithmetic of the experiment and control values was not statistically reliable. The tolerance of the plasma to heparin as a function of the exposure time to the CMF of the plasma was considerably modified, an was statistically reliable.

  13. Clinical and prognostic significance of coagulation assays in lung cancer.

    Science.gov (United States)

    Tas, Faruk; Kilic, Leyla; Serilmez, Murat; Keskin, Serkan; Sen, Fatma; Duranyildiz, Derya

    2013-03-01

    Activation of coagulation and fibrinolysis is frequently encountered among cancer patients. Such tumors are supposed to be associated with higher risk of invasion, metastases and eventually worse outcome. The aim of this study is to explore the prognostic value of blood coagulation tests for lung cancer patients. The study comprised 110 lung cancer patients. Pretreatment blood coagulation tests including PT, aPTT, PTA, INR, D-dimer, fibrinogen levels and platelet counts were evaluated. The plasma level of all coagulation tests revealed statistically significant difference between patient and control group (p coagulation parameters (p = 0.05). In conclusion, elevation of PT and INR are associated with decreased survival in lung cancer patients.

  14. Simulation of nanoparticle coagulation in radio-frequency C2H2/Ar microdischarges

    Science.gov (United States)

    Xiang-Mei, Liu; Qi-Nan, Li; Rui, Li

    2016-06-01

    The nanoparticle coagulation is investigated by using a couple of fluid models and aerosol dynamics model in argon with a 5% molecular acetylene admixture rf microdischarges, with the total input gas flow rate of 400 sccm. It co-exists with a homogeneous, secondary electron-dominated low temperature γ-mode glow discharges. The heat transfer equation and flow equation for neutral gas are taken into account. We mainly focused on investigations of the nanoparticle properties in atmospheric pressure microdischarges, and discussed the influences of pressure, electrode spacing, and applied voltage on the plasma density and nanoparticle density profiles. The results show that the characteristics of microdischarges are quite different from those of low pressure radio-frequency discharges. First, the nanoparticle density in the bulk plasma in microdischarges is much larger than that of low pressure discharges. Second, the nanoparticle density of 10 nm experiences an exponential increase as soon as the applied voltage increases, especially in the presheath. Finally, as the electrode spacing increases, the nanoparticle density decreased instead of increasing. Project supported by the Natural Science Foundation of Heilongjiang Province, China (Grant Nos. A2015011 and A2015010), the Postdoctoral Scientific Research Development Fund of Heilongjiang Province, China (Grant No. LBH-Q14159), the Program for Young Teachers Scientific Research in Qiqihar University (Grant No. 2014k-Z11), the National Natural Science Foundation of China (Grant No. 11404180), and the University Nursing Program for Yong Scholars with Creative Talents in Heilongjiang Province, China (Grant No. UNPYSCT-2015095).

  15. Depleted argon from underground sources

    Energy Technology Data Exchange (ETDEWEB)

    Back, H.O.; /Princeton U.; Alton, A.; /Augustana U. Coll.; Calaprice, F.; Galbiati, C.; Goretti, A.; /Princeton U.; Kendziora, C.; /Fermilab; Loer, B.; /Princeton U.; Montanari, D.; /Fermilab; Mosteiro, P.; /Princeton U.; Pordes, S.; /Fermilab

    2011-09-01

    Argon is a powerful scintillator and an excellent medium for detection of ionization. Its high discrimination power against minimum ionization tracks, in favor of selection of nuclear recoils, makes it an attractive medium for direct detection of WIMP dark matter. However, cosmogenic {sup 39}Ar contamination in atmospheric argon limits the size of liquid argon dark matter detectors due to pile-up. The cosmic ray shielding by the earth means that Argon from deep underground is depleted in {sup 39}Ar. In Cortez Colorado a CO{sub 2} well has been discovered to contain approximately 500ppm of argon as a contamination in the CO{sub 2}. In order to produce argon for dark matter detectors we first concentrate the argon locally to 3-5% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation. The N{sub 2} and He will be removed by continuous cryogenic distillation in the Cryogenic Distillation Column recently built at Fermilab. In this talk we will discuss the entire extraction and purification process; with emphasis on the recent commissioning and initial performance of the cryogenic distillation column purification.

  16. The Liquid Argon Purity Demonstrator

    CERN Document Server

    Adamowski, M; Dvorak, E; Hahn, A; Jaskierny, W; Johnson, C; Jostlein, H; Kendziora, C; Lockwitz, S; Pahlka, B; Plunkett, R; Pordes, S; Rebel, B; Schmitt, R; Stancari, M; Tope, T; Voirin, E; Yang, T

    2014-01-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  17. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  18. Proteome of human plasma very low-density lipoprotein and low-density lipoprotein exhibits a link with coagulation and lipid metabolism

    NARCIS (Netherlands)

    Dashty Rahmatabady, Monireh; Motazacker, Mohammad M.; Levels, Johannes; de Vries, Marcel; Mahmoudi, Morteza; Peppelenbosch, Maikel; Rezaee, Farhad

    2014-01-01

    Apart from transporting lipids through the body, the human plasma lipoproteins very low-density lipoprotein (VLDL) and low-density lipoprotein (LDL) are also thought to serve as a modality for intra-organismal protein transfer, shipping proteins with important roles in inflammation and thrombosis fr

  19. Proton Scattering on Liquid Argon

    Science.gov (United States)

    Bouabid, Ryan; LArIAT Collaboration

    2017-01-01

    LArIAT (Liquid Argon In A Test-beam) is a liquid argon time projection chamber (LArTPC) positioned in a charged particle beamline whose primary purpose is to study the response of LArTPC's to charged particle interactions. This previously unmeasured experimental data will allow for improvement of Monte Carlo simulations and development of identification techniques, important for future planned LArTPC neutrino experiments. LArIAT's beamline is instrumented to allow for the identification of specific particles as well as measurement of those particles' incoming momenta. Among the particles present in the beamline, the analysis presented here focuses on proton-Argon interactions. This study uses particle trajectories and calorimetric information to identify proton-Argon interaction candidates. We present preliminary data results on the measurement of the proton-Argon cross-section. Liquid Argon In A Test Beam. The work is my analysis made possible through the efforts of LArIAT detector, data, and software.

  20. Tailoring the surface properties of polypropylene films through cold atmospheric pressure plasma (CAPP) assisted polymerization and immobilization of biomolecules for enhancement of anti-coagulation activity

    Energy Technology Data Exchange (ETDEWEB)

    Navaneetha Pandiyaraj, K., E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L& T By Pass, Chinniyam Palayam (Post), Coimbatore 641062 (India); Ram Kumar, M.C.; Arun Kumar, A. [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L& T By Pass, Chinniyam Palayam (Post), Coimbatore 641062 (India); Padmanabhan, P.V.A. [PSN College of Engineering and Technology, Tirunelveli 627 152 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Bah, M.; Ismat Shah, S. [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark (United States); Su, Pi-Guey [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Halleluyah, M.; Halim, A.S. [School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2016-05-01

    Graphical abstract: - Highlights: • Developed low cost cold atmospheric plasma reactor for plasma polymerization technique. • Surface of the PP film was modified by grafting of AAc and PEG by CAPP polymerization. • Biomolecules of chitosan, insulin and heparin were immobilized on surface of PEG-AAc grafted PP films. • The surface modified PP films were characterized by various techniques. • The plasma polymerized and immobilized film reveals substantial blood compatibility. - Abstract: Enhancement of anti-thrombogenic properties of polypropylene (PP) to avert the adsorption of plasma proteins (fibrinogen and albumin), adhesion and activation of the platelets are very important for vast biomedical applications. The cold atmospheric pressure plasma (CAPP) assisted polymerization has potential to create the specific functional groups such as O−C=O, C=O, C−N and S−S. on the surface of polymeric films using selective precursor in vapour phase to enhance anti-thrombogenic properties. Such functionalized polymeric surfaces would be suitable for various biomedical applications especially to improve the blood compatibility. The eventual aspiration of the present investigation is to develop the biofunctional coating onto the surface of PP films using acrylic acid (AAc) and polyethylene glycol (PEG) as a precursor in a vapour phase by incorporating specific functional groups for immobilization of biomolecules such as heparin (HEP), chitosan (CHI) and insulin (INS) on the surface of plasma modified PP films. The surface properties such as hydrophilicity, chemical composition, surface topography of the surface modified PP films were analyzed by contact angle (CA), Fourier transform infrared spectroscopy (FTIR), X-ray photo electron spectroscopy (XPS) and atomic force microscopy (AFM). Furthermore the anti-thrombogenic properties of the surface modified PP films were studied by in vitro tests which include platelet adhesion and protein adsorption analysis. It was

  1. Genotype–phenotype relationship of F7 R353Q polymorphism and plasma factor VII coagulant activity in Asian Indian families predisposed to coronary artery disease

    Indian Academy of Sciences (India)

    Jayashree Shanker; Ganapathy Perumal; Arindam Maitra; Veena S. Rao; B. K. Natesha; Shibu John; Sridhar Hebbagodi; Vijay V. Kakkar

    2009-12-01

    Elevated factor VII (FVII) level is a risk factor for coronary artery disease (CAD). We investigated the role of R353Q polymorphism in the F7 gene in 139 Indian families with CAD, comprising of 222 affected subjects, 105 unaffected subjects and 126 affected sibling pairs. Plasma per cent FVIIc activity (FVII.c activity) differed significantly across R353Q genotype ($P \\lt 0.0001$). Frequency of subjects with RR and QQ genotypes were higher in 4th quartile and 1st quartile of FVII.c activity, respectively ($P \\lt 0.0001$). F7 R353Q SNP was able to explain up to 7% of variation in FVII.c activity by regression analysis and an additive genetic component of variance of 28.04% by heritability analysis. Quantitative trait loci analysis showed suggestive linkage evidence of F7 SNP with per cent FVII.c activity (LOD score $-1.82$; $P = 0.002$). Individuals with RR and RQ genotypes carried an OR of 2.071 (95% c.i. = 1.506–2.850) and 2.472 (95% c.i. = 1.679–3.641), respectively, towards CAD risk. There was significant correlation of FVII.c activity with lipid markers, particularly among those with RR and RQ genotype after covariate adjustment. In conclusion, the F7 R353Q SNP appears to moderately influence plasma FVII.c activity and risk of CAD in Indians.

  2. Attachment cooling of electrons in oxygen-argon and SF6-argon mixtures

    Science.gov (United States)

    Babaeva, Natalia; Kim, Sung Jin; Park, Gan Young; Lee, Jae Koo

    2004-09-01

    In e-beam sustained plasma different electron temperature can be obtained. Thus, in plasma of capacitive RF discharges in inert gases typical electron temperature is of the order of 2-3 eV. At certain conditions, in plasma of electronegative gases electron temperature can approach ion/neutral temperature. We consider e-beam sustained plasma of electronegative gases and their mixtures with argon where the main mechanism of plasma neutralization is connected with electron-molecule attachment. In such plasma, due to retardation of fast electrons of e-beam secondary electrons are created which loose their energy due to attachment. It is shown, that at certain conditions (in dependence of the e-beam intensity and spectrum of secondary electrons) electron temperature can obtain the values comparable or even less than temperature of neutral component. The effect can be explained by the increase of attachment rate coefficient with the increase of electron temperature (mean electron energy). Such a dependence leads to attachment of the fastest plasma electrons and selective loss of electrons whose energy exceeds the mean electron energy and, as a result, to effective electron cooling. The theoretical and numerical analysis of the problem has been conducted. The numerical results obtained using ELENDIF code are compared with Particle-in-cell/Monte Carlo simulations under similar conditions.

  3. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  4. Tailoring the surface properties of polypropylene films through cold atmospheric pressure plasma (CAPP) assisted polymerization and immobilization of biomolecules for enhancement of anti-coagulation activity

    Science.gov (United States)

    Navaneetha Pandiyaraj, K.; Ram Kumar, M. C.; Arun Kumar, A.; Padmanabhan, P. V. A.; Deshmukh, R. R.; Bah, M.; Ismat Shah, S.; Su, Pi-Guey; Halleluyah, M.; Halim, A. S.

    2016-05-01

    Enhancement of anti-thrombogenic properties of polypropylene (PP) to avert the adsorption of plasma proteins (fibrinogen and albumin), adhesion and activation of the platelets are very important for vast biomedical applications. The cold atmospheric pressure plasma (CAPP) assisted polymerization has potential to create the specific functional groups such as Osbnd Cdbnd O, Cdbnd O, Csbnd N and Ssbnd S. on the surface of polymeric films using selective precursor in vapour phase to enhance anti-thrombogenic properties. Such functionalized polymeric surfaces would be suitable for various biomedical applications especially to improve the blood compatibility. The eventual aspiration of the present investigation is to develop the biofunctional coating onto the surface of PP films using acrylic acid (AAc) and polyethylene glycol (PEG) as a precursor in a vapour phase by incorporating specific functional groups for immobilization of biomolecules such as heparin (HEP), chitosan (CHI) and insulin (INS) on the surface of plasma modified PP films. The surface properties such as hydrophilicity, chemical composition, surface topography of the surface modified PP films were analyzed by contact angle (CA), Fourier transform infrared spectroscopy (FTIR), X-ray photo electron spectroscopy (XPS) and atomic force microscopy (AFM). Furthermore the anti-thrombogenic properties of the surface modified PP films were studied by in vitro tests which include platelet adhesion and protein adsorption analysis. It was found that the anti-thrombogenic properties of the PP films are effectively controlled by the CAPP grafting of AAc and PEG followed by immobilization of biomolecules of heparin, chitosan and insulin. The grafting and immobilization was confirmed by FTIR and XPS through the recognition of specific functional groups such as COOH, Csbnd O, Ssbnd S and Csbnd N. on the surface of PP film. Furthermore, the surface morphology and hydrophilic nature of the PP films also tailored

  5. Overview of the coagulation system

    Directory of Open Access Journals (Sweden)

    Sanjeev Palta

    2014-01-01

    Full Text Available Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ′coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  6. A novel mutation in a patient with congenital coagulation factor Ⅻ deficiency

    Institute of Scientific and Technical Information of China (English)

    FENG Ying; YE Xu; PANG Ying; DAI Jing; WANG Xue-feng; ZHOU Xu-hong

    2008-01-01

    @@ Human coagulation factor Ⅻ(FⅫ),also called Hageman factor,is a plasma plycoprotein that is functionally deficient in individuals with Hageman trait:which is an inhefited trait discovered by chance during preoperative blood coagulation screening tests.FⅫ is a single-chain 596-amino-acid zymogen of a serine protease with an approximate molecular weight of 80 000.

  7. Topical allogeneic platelet-rich plasma treatment for a massive cutaneous lesion induced by disseminated intravascular coagulation in a toy breed dog.

    Science.gov (United States)

    Chung, Tae-Ho; Baek, Dae-Seung; Kim, Namjung; Park, Jin-Ho; Park, Chul

    2015-01-01

    A 2-year-old intact female miniature Pinscher weighing 1.7 kg with a body condition score of 2/5 was presented for acute vomiting, lethargy for 2 days, and large petechial skin lesions on the hip region including the tail. Acute pancreatitis was diagnosed by clinical signs, strong positive cPLI test, laboratory test and ultrasound appearance. While the clinical signs associated with acute pancreatitis had improved in 3-5 days, lesion of petechial appeared on the left hip region 7 days after the presentation, with a fast progression into a necrotic tissue along the left side hip. Allogenic platelet rich plasma (PRP) with Weibrich and Kleis method was administered to promote skin healing and regeneration. Gradual and complete improvement in the dog's wound lesions was noted approximately 1 month after applying allogeneic topical PRP. In this case report, allogeneic PRP was applied to a large regional cutaneous defect caused by coagulopathy induced by acute pancreatitis. Topical application of PRP in this case was unique in that allogeneic PRP was used instead of autologous PRP for the first time in cutaneous soft-tissue wound management in the veterinary medical field.

  8. How Is Disseminated Intravascular Coagulation Treated?

    Science.gov (United States)

    ... the NHLBI on Twitter. How Is Disseminated Intravascular Coagulation Treated? Treatment for disseminated intravascular coagulation (DIC) depends ... and treat the underlying cause. Acute Disseminated Intravascular Coagulation People who have acute DIC may have severe ...

  9. Disseminated intravascular coagulation in cancer patients

    NARCIS (Netherlands)

    M. Levi

    2009-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome that may complicate a variety of diseases, including malignant disease. DIC is characterized by widespread, intravascular activation of coagulation (leading to intravascular fibrin deposition) and simultaneous consumption of coagulation fact

  10. Influences of fresh frozen plasma with different melting temperatures on coagulation factor and fibrinogen activity%新鲜冰冻血浆不同融解温度对凝血因子及纤维蛋白原活性的影响

    Institute of Scientific and Technical Information of China (English)

    赵凯

    2016-01-01

    目的:探讨不同融解温度对新鲜冰冻血浆凝血因子及纤维蛋白原活性的影响。方法随机选取40份新鲜冰冻血浆,分别在37℃、42℃、45℃水浴中充分进行融解,检测纤维蛋白原(FIB)、凝血Ⅷ因子、总蛋白(TP)含量,进行统计学分析。结果42℃组与37℃组新鲜冰冻血浆凝血Ⅷ因子、FIB、TP差异均无统计学意义(P>0.05)。45℃组与37℃组新鲜冰冻血浆FIB、TP差异均无统计学意义(P>0.05),45℃融解新鲜冰冻血浆凝血Ⅷ因子水平较37℃低,差异具有统计学意义(P<0.05)。结论随着融解温度升高,新鲜冰冻血浆凝血因子活性呈降低趋势,37℃为较佳融解温度。%Objective To explore the influences of fresh frozen plasma with different melting temperatures on coagulation factor and fibrinogen activity. Methods 40 samples of fresh frozen plasma were selected and sufficiently melted at 37℃, 42℃, 45℃ water bath respectively. The contents of fibrinogen (FIB), coagulation factor VIII, total protein (TP) were detected and statistically analyzed. Results There wad no difference in contents of FIB, coagulation factor VIII, TP between 42℃ group and 37℃ group (P>0.05). There wad no difference in contents of FIB, TP between 45℃ group and 37℃ group (P>0.05). The content of coagulation factor VIII in 45℃ group was lower than that in 37℃ group (P<0.05). Conclusion The coagulation factor activity of fresh frozen plasma was decreased when the melting temperature increased. 37℃ was the better choice of melting temperature.

  11. Attainable superheat of argon-helium, argon-neon solutions.

    Science.gov (United States)

    Baidakov, Vladimir G; Kaverin, Aleksey M; Andbaeva, Valentina N

    2008-10-16

    The method of lifetime measurement has been used to investigate the kinetics of spontaneous boiling-up of superheated argon-helium and argon-neon solutions. Experiments were made at a pressure of p = 1.5 MPa and concentrations up to 0.33 mol% in the range of nucleation rates from 10 (4) to 10 (8) s (-1) m (-3). The homogeneous nucleation regime has been distinguished. With good agreement between experimental data and homogeneous nucleation theory in temperature and concentration dependences of the nucleation rate, a systematic underestimation by 0.25-0.34 K has been revealed in superheat temperatures over the saturated line attained by experiment as compared with theoretical values calculated in a macroscopic approximation. The revealed disagreement between theory and experiment is connected with the dependence of the properties of new-phase nuclei on their size.

  12. Tissue regenerating functions of coagulation factor XIII

    DEFF Research Database (Denmark)

    Soendergaard, C; Kvist, P H; Seidelin, J B;

    2013-01-01

    The protransglutaminase factor XIII (FXIII) has recently gained interest within the field of tissue regeneration, as it has been found that FXIII significantly influences wound healing by exerting a multitude of functions. It supports haemostasis by enhancing platelet adhesion to damaged......-receptor 2 and the αVβ3 integrin is important for angiogenesis supporting formation of granulation tissue. Chronic inflammatory conditions involving bleeding and activation of the coagulation cascade have been shown to lead to reduced FXIII levels in plasma. Of particular importance for this review...

  13. Monocytes regulate systemic coagulation and inflammation in abdominal sepsis.

    Science.gov (United States)

    Wang, Yongzhi; Braun, Oscar Ö; Zhang, Su; Norström, Eva; Thorlacius, Henrik

    2015-03-01

    Abdominal sepsis is associated with significant changes in systemic inflammation and coagulation. The purpose of the present study was to examine the role of peripheral blood monocytes for systemic coagulation, including thrombin generation and consumption of coagulation factors. Abdominal sepsis was induced by cecal ligation and puncture (CLP) in C57BL/6 mice. Plasma and lung levels of IL-6 and C-X-C motif (CXC) chemokines [chemokine CXC ligand (CXCL)1, CXCL2, and CXCL5], pulmonary activity of myeloperoxidase, thrombin generation, and coagulation factors were determined 6 h after CLP induction. Administration of clodronate liposomes decreased circulating levels of monocytes by 96%. Time to peak thrombin formation was increased and peak and total thrombin generation was decreased in plasma from CLP animals. Monocyte depletion decreased time to peak formation of thrombin and increased peak and total generation of thrombin in septic animals. In addition, monocyte depletion decreased the CLP-induced increase in the levels of thrombin-antithrombin complexes in plasma. Depletion of monocytes increased plasma levels of prothrombin, factor V, factor X, and protein C in septic mice. Moreover, depletion of monocytes decreased CLP-induced levels of IL-6 and CXC chemokines in the plasma and lung by >59% and 20%, respectively. CLP-induced myeloperoxidase activity in the lung was attenuated by 44% in animals depleted of monocytes. Taken together, our findings show, for the first time, that peripheral blood monocytes regulate systemic coagulation. The results of our study improve our understanding of the pathophysiology of sepsis and encourage further attempts to target innate immune cell functions in abdominal sepsis.

  14. Liquid Argon Barrel Cryostat Arrived

    CERN Multimedia

    Pailler, P

    Last week the first of three cryostats for the ATLAS liquid argon calorimeter arrived at CERN. It had travelled for 46 days over several thousand kilometers from Japan to CERN. During three years it has been fabricated by Kawasaki Heavy Industries Ltd. at Harima, close to Kobe, under contract from Brookhaven National Laboratory (BNL) of the U.S.. This cryostat consists of two concentric cylinders made of aluminium: the outer vacuum vessel with a diameter of 5.5 m and a length of 7 m, and the inner cold vessel which will contain the electromagnetic barrel calorimeter immersed in liquid argon. The total weight will be 270 tons including the detectors and the liquid argon. The cryostat is now located in building 180 where it will be equipped with 64 feed-throughs which serve for the passage of 122,880 electrical lines which will carry the signals of the calorimeter. After integration of the calorimeter, the solenoidal magnet of ATLAS will be integrated in the vacuum vessel. A final cold test of the cryostat inc...

  15. Extremely refractory Kawasaki disease with disseminated intravascular coagulation.

    Science.gov (United States)

    Koh, Young Kwon; Lee, Jae Hee; Park, Yeong Bong

    2017-03-07

    Disseminated intravascular coagulation is a rare complication of Kawasaki disease and appears in Kawasaki disease patients. We report a case of refractory Kawasaki disease complicated with disseminated intravascular coagulation and giant coronary aneurysm. A 5-month-old boy presented with Kawasaki disease with coagulopathy. Although the coagulopathy improved after fresh-frozen plasma and antithrombin-III administration, the fever persisted despite two rounds of intravenous immunoglobulin, along with intravenous methylprednisolone pulse therapy and infliximab administration. Despite all efforts to treatment, the patient had giant coronary aneurysms and died suddenly.

  16. Argon-krypton ion laser as light source for medical photocoagulation applications

    Science.gov (United States)

    Kamiński, Wojciech; Warda, Piotr; Kasprzak, Jan; Kesik, Jerzy

    2013-01-01

    Photocoagulators are one of the most popular laser devices in medicine. Due to different kind of interaction of particular wavelength range of laser light with live tissues, sources of laser radiation which can cover as much as possible of visible spectrum are still very wanted (see [1,2]). In last years it also can be observed the intensive developing works on new photocoagulation technique called "micropulse coagulation" [3,4]. The most critical feature of lasers for micropulse coagulation is the possibility of fast switching between two selected laser power values. It seems that the good proposal for these applications can be ion laser filled with argon-krypton mixture. Authors previously have indicated the possibility of improvement of generation conditions in this type of laser in presence of buffer gases [5,6] and with use developed by authors pulse supply regime [7,8]. These improvements allow to obtain output power values of most important argon and krypton laser lines in laser filled with mixture of both gases, similar to values available in laser filled with pure gases. Presented in this paper the following researches are concerned on verification of possibilities of use of the developed laser system in photocoagulation with possibility of use of the laser system in micropulse coagulation technique.

  17. Physiological levels of blood coagulation factors IX and X control coagulation kinetics in an in vitro model of circulating tissue factor

    Science.gov (United States)

    Tormoen, Garth W.; Khader, Ayesha; Gruber, András; McCarty, Owen J. T.

    2013-06-01

    Thrombosis significantly contributes to cancer morbidity and mortality. The mechanism behind thrombosis in cancer may be circulating tissue factor (TF), as levels of circulating TF are associated with thrombosis. However, circulating TF antigen level alone has failed to predict thrombosis in patients with cancer. We hypothesize that coagulation factor levels regulate the kinetics of circulating TF-induced thrombosis. Coagulation kinetics were measured as a function of individual coagulation factor levels and TF particle concentration. Clotting times increased when pooled plasma was mixed at or above a ratio of 4:6 with PBS. Clotting times increased when pooled plasma was mixed at or above a ratio of 8:2 with factor VII-depleted plasma, 7:3 with factor IX- or factor X-depleted plasmas, or 2:8 with factor II-, V- or VIII-depleted plasmas. Addition of coagulation factors VII, X, IX, V and II to depleted plasmas shortened clotting and enzyme initiation times, and increased enzyme generation rates in a concentration-dependent manner. Only additions of factors IX and X from low-normal to high-normal levels shortened clotting times and increased enzyme generation rates. Our results demonstrate that coagulation kinetics for TF particles are controlled by factor IX and X levels within the normal physiological range. We hypothesize that individual patient factor IX and X levels may be prognostic for susceptibility to circulating TF-induced thrombosis.

  18. Purification of coagulation factor VIII by immobilized metal affinity chromatography.

    Science.gov (United States)

    Rodrigues, Estela S; Verinaud, Claudia I; Oliveira, Douglas S; Raw, Isaías; Lopes, Alexandre P Y; Martins, Elizabeth A L; Cheng, Elisabeth

    2015-01-01

    Factor VIII (FVIII) is a glycoprotein that plays an essential role in blood coagulation cascade. Purification of plasma-derived coagulation FVIII by direct application of plasma to a chromatographic column is a method of choice. Anion exchange column is a very powerful method because FVIII is strongly adsorbed, resulting in good activity recovery and high purification factor. However, vitamin-K-dependent coagulation factors coelute with FVIII. In the present study, we report the separation of vitamin-K-dependent coagulation proteins from FVIII using immobilized metal affinity chromatography (IMAC) with Cu(2+) as the metal ligand. Plasma was directly loaded to a Q Sepharose Big Beads column, and FVIII was recovered with 65% activity and a purification factor of approximately 50 times. Then, the Q Sepharose eluate was applied to the IMAC-Cu(2+) column, and FVIII was eluted with 200 mM imidazole, with up to 85% recovery of activity. The mass recovery in this fraction was less than 10% of the applied mass of protein. Vitamin-K-dependent proteins elute with imidazole concentrations of lower than 60 mM. Because of the difference in affinity, FVIII could be completely separated from the vitamin-K-dependent proteins in the IMAC column.

  19. 21 CFR 864.5400 - Coagulation instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400....5400 Coagulation instrument. (a) Identification. A coagulation instrument is an automated or semiautomated device used to determine the onset of clot formation for in vitro coagulation studies....

  20. Composing Experimental Environment of PRIDE Argon cell

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Seonho; Jang, Yongkuk; Cho, Il Je [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In PRIDE depleted Uranium feed material and a depleted Uranium mixed with some surrogate material are used for performing engineering scale Pyroprocessing. PRIDE has to maintain inert atmosphere because of the characteristic of Electrolytic Reduction technology, Electro refining technology, Electrowinning technology. The impurity concentration of the Argon cell has to be under 50 ppm(Oxygen, moisture). Atmospheric pressure changes and temperature changes can affect the Argon cell's impurity concentration. In this paper, how to compose the Argon cell impurity concentration under 50 ppm to make the exact optimal experimental environment(Oxygen, moisture) will be introduced. Composing the exact optimal experimental environment by supplying Argon gas have been introduced in this paper. Continuously supplying Argon gas which is heavier than the Oxygen through the bottom of the Argon cell the oxygen eventually discharged through the high vent fan and lower the impurity concentration of Oxygen.

  1. Disorders of coagulation in pregnancy.

    Science.gov (United States)

    Katz, D; Beilin, Y

    2015-12-01

    The process of haemostasis is complex and is further complicated in the parturient because of the physiological changes of pregnancy. Understanding these changes and the impact that they have on the safety profile of the anaesthetic options for labour and delivery is crucial to any anaesthetist caring for the parturient. This article analyses current theories on coagulation and reviews the physiological changes to coagulation that occur during pregnancy and the best methods with which to evaluate coagulation. Finally, we examine some of the more common disorders of coagulation that occur during pregnancy, including von Willebrand disease, common factor deficiencies, platelet disorders, the parturient on anticoagulants, and the more rare acute fatty liver of pregnancy, with a focus on their implications for neuraxial anaesthesia.

  2. Obstetrical disseminated intravascular coagulation score.

    Science.gov (United States)

    Kobayashi, Takao

    2014-06-01

    Obstetrical disseminated intravascular coagulation (DIC) is usually a very acute, serious complication of pregnancy. The obstetrical DIC score helps with making a prompt diagnosis and starting treatment early. This DIC score, in which higher scores are given for clinical parameters rather than for laboratory parameters, has three components: (i) the underlying diseases; (ii) the clinical symptoms; and (iii) the laboratory findings (coagulation tests). It is justifiably appropriate to initiate therapy for DIC when the obstetrical DIC score reaches 8 points or more before obtaining the results of coagulation tests. Improvement of blood coagulation tests and clinical symptoms are essential to the efficacy evaluation for treatment after a diagnosis of obstetrical DIC. Therefore, the efficacy evaluation criteria for obstetrical DIC are also defined to enable follow-up of the clinical efficacy of DIC therapy.

  3. Plasmin-induced procoagulant effects in the blood coagulation: a crucial role of coagulation factors V and VIII.

    Science.gov (United States)

    Ogiwara, Kenichi; Nogami, Keiji; Nishiya, Katsumi; Shima, Midori

    2010-09-01

    Plasminogen activators provide effective treatment for patients with acute myocardial infarction. However, paradoxical elevation of thrombin activity associated with failure of clot lysis and recurrent thrombosis has been reported. Generation of thrombin in these circumstances appears to be owing to plasmin (Plm)-induced activation of factor (F) XII. Plm catalyzes proteolysis of several coagulant factors, but the roles of these factors on Plm-mediated procoagulant activity remain to be determined. Recently developed global coagulation assays were used in this investigation. Rotational thromboelastometry using whole blood, clot waveform analysis and thrombin generation tests using plasma, showed that Plm (> or =125 nmol/l) shortened the clotting times in similar dose-dependent manners. In particular, the thrombin generation test, which was unaffected by products of fibrinolysis, revealed the enhanced coagulation with an approximately two-fold increase of peak level of thrombin generation. Studies using alpha2-antiplasmin-deficient plasma revealed that much lower dose of Plm (> or =16 nmol/l) actually contributed to enhancing thrombin generation. The shortening of clotting time could be observed even in the presence of corn trypsin inhibitor, supporting that Plm exerted the procoagulant activity independently of FXII. In addition, using specific coagulation-deficient plasmas, the clot waveform analysis showed that Plm did not shorten the clotting time in only FV-deficient or FVIII-deficient plasma in prothrombin time-based or activated partial thromboplastin time-based assay, respectively. Our results indicated that Plm did possess procoagulant activity in the blood coagulation, and this effect was likely attributed by multicoagulation factors, dependent on FV and/or FVIII.

  4. Structural determination of argon trimer

    Directory of Open Access Journals (Sweden)

    Xiguo Xie

    2015-09-01

    Full Text Available Rare gas clusters are model systems to investigate structural properties at finite size. However, their structures are difficult to be determined with available experimental techniques because of the strong coupling between the vibration and the rotation. Here we experimentally investigated multiple ionization and fragmentation dynamics of argon trimer by ultrashort intense laser fields and reconstructed their structures with Coulomb explosion technique. The measured structure distribution was compared with our finite-temperature ab initio calculations and the discrepancy was discussed. The present study provides a guidance for the development of theoretical methods for exploring the geometric structure of rare gas clusters.

  5. The scintillation of liquid argon

    CERN Document Server

    Heindl, T; Hofmann, M; Krücken, R; Oberauer, L; Potzel, W; Wieser, J; Ulrich, A

    2015-01-01

    A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd excimer continuum. Various additional emission features were found. The time structure of the light emission has been measured for a set of well defined wavelength positions. The results help to interpret literature data in the context of liquid rare gas detectors in which the wavelength information is lost due to the use of wavelength shifters.

  6. Coagulation tests show significant differences in patients with breast cancer.

    Science.gov (United States)

    Tas, Faruk; Kilic, Leyla; Duranyildiz, Derya

    2014-06-01

    Activated coagulation and fibrinolytic system in cancer patients is associated with tumor stroma formation and metastasis in different cancer types. The aim of this study is to explore the correlation of blood coagulation assays for various clinicopathologic factors in breast cancer patients. A total of 123 female breast cancer patients were enrolled into the study. All the patients were treatment naïve. Pretreatment blood coagulation tests including PT, APTT, PTA, INR, D-dimer, fibrinogen levels, and platelet counts were evaluated. Median age of diagnosis was 51 years old (range 26-82). Twenty-two percent of the group consisted of metastatic breast cancer patients. The plasma level of all coagulation tests revealed statistically significant difference between patient and control group except for PT (p50 years) was associated with higher D-dimer levels (p=0.003). Metastatic patients exhibited significantly higher D-dimer values when compared with early breast cancer patients (p=0.049). Advanced tumor stage (T3 and T4) was associated with higher INR (p=0.05) and lower PTA (p=0.025). In conclusion, coagulation tests show significant differences in patients with breast cancer.

  7. Carbon monoxide and iron modulate plasmatic coagulation in Alzheimer's disease.

    Science.gov (United States)

    Nielsen, Vance G; Pretorius, Etheresia; Bester, Janette; Jacobsen, Wayne K; Boyle, Patrick K; Reinhard, Joao P

    2015-01-01

    Alzheimer's disease (AD) is a significant source of morbidity and mortality for millions of people worldwide, and multiple potential etiologies have been postulated to contribute to AD. Among these, spontaneous cerebral emboli and increased cerebral and circulating heme oxygenase (Hmox) activity in AD patients are of particular interest, as two of the products of Hmox activity, carbon monoxide (CO) and iron enhance plasmatic coagulation and modify the ultrastructure of thrombi. We hypothesized that patients afflicted with AD would have coagulation kinetics modulated by CO and iron. Using viscoelastic assessments of coagulation, it was determined with a small cohort (n=11) of AD patients that all had enhancement of coagulation by CO, iron, or both. In a complementary fashion, it was determined that a separate cohort (n=12) of AD patients had thrombi with ultrastructural features consistent with iron and CO exposure as assessed with scanning electron microscopy. Further, when stratified by normal or abnormally increased serum ferritin concentrations (which can be increased by Hmox), the AD patients with abnormal ferritin concentrations had significantly thinner fibrin fiber diameters, not unlike that noted when normal plasma is mixed with iron or CO. In sum, AD patients were noted to have plasmatic coagulation kinetic and thrombus ultrastructural changes consistent with exposure to CO and iron. Future investigation of CO and iron in the pathogenesis of Alzheimer's disease is warranted.

  8. Separation of seven arsenic compounds by high-performance liquid chromatography with on-line detection by hydrogen–argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, E. H.; Pritzl, G.

    1992-01-01

    Seven molecular forms of arsenic were separated by anion- and cation-exchange high-performance liquid chromatography (HPLC) with on-line detection by flame atomic absorption spectrometry (FAAS). The interfacing was established by a vented poly(tetrafluoroethylene) capillary tubing connecting...... the HPLC column to the nebulizer of the atomic absorption spectrometer. Arsenite, arsenate, monomethylarsonate (MMA) and dimethylarsinate (DMA) were separated from each other and from the co-injected cationic arsenic compounds, arsenobetaine (AsB), arsenocholine (AsC) and the tetramethylarsonium ion (TMAs......-to-noise ratio of the on-line AAS detector was optimized. This involved the use of the hydrogen-argon-entrained air flame, a slotted tube atom trap in the flame for signal enhancement, electronic noise damping and a high-intensity light source. The detection limits in mu-g cm-3, using 100 mm3 injections...

  9. Separation of seven arsenic compounds by high performance liquid chromatography with on-line detection by hydrogen-argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, Erik Huusfeldt; Pritzl, G.

    1992-01-01

    Seven molecular forms of arsenic were separated by anion- and cation-exchange high-performance liquid chromatography (HPLC) with on-line detection by flame atomic absorption spectrometry (FAAS). The interfacing was established by a vented poly(tetrafluoroethylene) capillary tubing connecting...... the HPLC column to the nebulizer of the atomic absorption spectrometer. Arsenite, arsenate, monomethylarsonate (MMA) and dimethylarsinate (DMA) were separated from each other and from the co-injected cationic arsenic compounds, arsenobetaine (AsB), arsenocholine (AsC) and the tetramethylarsonium ion (TMAs......-to-noise ratio of the on-line AAS detector was optimized. This involved the use of the hydrogen-argon-entrained air flame, a slotted tube atom trap in the flame for signal enhancement, electronic noise damping and a high-intensity light source. The detection limits in mu-g cm-3, using 100 mm3 injections...

  10. Influence of easily ionised elements on the delayed responses of the emission intensities of an analyte in a power modulated U-shaped argon stabilised DC arc plasma with an aerosol supply

    Directory of Open Access Journals (Sweden)

    MIROSLAV KUZMANOVIC

    2005-09-01

    Full Text Available The current of a U-shaped argon stabilised DC arc was square modulated with a 40 Hz repetition frequency between 6 and 3 A. The delayed line intensity responses to the modulation of the arc current were investigated using calcium as a representative analyte. The intensities of both the atomic and ionic lines were monitored at different distances from the arc axis in the presence of various concentrations of the easily ionised element. Temporal evolutions were monitored on a millisecond time scale. It was found that the responses of the line intesity to the arc current change strongly depended on the observed radial position, especially in the vicinity of the arc axis. The obtained results showed a significant influence of even small amounts of the easily ionised element on the excitation and transport of the analyte and indicated a way of possibly improving the analytical capabilities of the excitation source.

  11. Effects of oxygen concentration on atmospheric pressure dielectric barrier discharge in Argon-Oxygen Mixture

    Science.gov (United States)

    Li, Xuechun; Li, Dian; Wang, Younian

    2016-09-01

    A dielectric barrier discharge (DBD) can generate a low-temperature plasma easily at atmospheric pressure and has been investigated for applications in trials in cancer therapy, sterilization, air pollution control, etc. It has been confirmed that reactive oxygen species (ROS) play a key role in the processes. In this work, we use a fluid model to simulate the plasma characteristics for DBD in argon-oxygen mixture. The effects of oxygen concentration on the plasma characteristics have been discussed. The evolution mechanism of ROS has been systematically analyzed. It was found that the ground state oxygen atoms and oxygen molecular ions are the dominated oxygen species under the considered oxygen concentrations. With the oxygen concentration increasing, the densities of electrons, argon atomic ions, resonance state argon atoms, metastable state argon atoms and excited state argon atoms all show a trend of decline. The oxygen molecular ions density is high and little influenced by the oxygen concentration. Ground state oxygen atoms density tends to increase before falling. The ozone density increases significantly. Increasing the oxygen concentration, the discharge mode begins to change gradually from the glow discharge mode to Townsend discharge mode. Project supported by the National Natural Science Foundation of China (Grant No. 11175034).

  12. [Modern coagulation management reduces the transfusion rate of allogenic blood products].

    Science.gov (United States)

    Weber, Christian Friedrich

    2012-06-01

    Evaluating the patient's individual bleeding history with a standardized questionnaire, using "point-of-care" - methods for coagulation analyses and providing autologous transfusion techniques are preconditions of a modern coagulation management. Therapy of coagulopathic patients should be based on structured hemotherapy algorithms. Surgical haemostasis and the maintenance of the basic conditions for haemostasis are elementary requirements for an effective therapy. In cases of diffuse bleeding, early antifibrinolytic therapy should be considered. Coagulation factor deficiencies should be corrected "goal-directed" using coagulation factor concentrates. Transfusion of fresh frozen plasma is only indicated in the clinical setting of massive transfusions. DDAVP and transfusion of platelet concentrates are options to optimize primary haemostasis. In cases of on-going bleeding, recombinant activated coagulation factor VII represents an option for "ultima-ratio" therapy.

  13. Argon purge gas cooled by chill box

    Science.gov (United States)

    Spiro, L. W.

    1966-01-01

    Cooling argon purge gas by routing it through a shop-fabricated chill box reduces charring of tungsten inert gas torch head components. The argon gas is in a cooled state as it enters the torch and prevents buildup of char caused by the high concentrations of heat in the weld area during welding operations.

  14. Depinning as a coagulation process

    Science.gov (United States)

    İşeri, M.; Kaspar, D.; Mungan, M.

    2016-08-01

    We consider a one-dimensional model that describes the depinning of an elastic string of particles in a strongly pinning, phase-disordered periodic environment under a slowly increasing force. The evolution towards depinning occurs by the triggering of avalanches in regions of activity which are at first isolated, but later grow and merge. For large system sizes the dynamically critical behavior is dominated by the coagulation of these active regions. Our analysis and numerical simulations show that the evolution of the sizes of active regions is well described by a Smoluchowski coagulation equation, allowing us to predict correlation lengths and avalanche sizes in terms of certain moments of the size distribution.

  15. Modelling of Complex Plasmas

    Science.gov (United States)

    Akdim, Mohamed Reda

    2003-09-01

    Nowadays plasmas are used for various applications such as the fabrication of silicon solar cells, integrated circuits, coatings and dental cleaning. In the case of a processing plasma, e.g. for the fabrication of amorphous silicon solar cells, a mixture of silane and hydrogen gas is injected in a reactor. These gases are decomposed by making a plasma. A plasma with a low degree of ionization (typically 10_5) is usually made in a reactor containing two electrodes driven by a radio-frequency (RF) power source in the megahertz range. Under the right circumstances the radicals, neutrals and ions can react further to produce nanometer sized dust particles. The particles can stick to the surface and thereby contribute to a higher deposition rate. Another possibility is that the nanometer sized particles coagulate and form larger micron sized particles. These particles obtain a high negative charge, due to their large radius and are usually trapped in a radiofrequency plasma. The electric field present in the discharge sheaths causes the entrapment. Such plasmas are called dusty or complex plasmas. In this thesis numerical models are presented which describe dusty plasmas in reactive and nonreactive plasmas. We started first with the development of a simple one-dimensional silane fluid model where a dusty radio-frequency silane/hydrogen discharge is simulated. In the model, discharge quantities like the fluxes, densities and electric field are calculated self-consistently. A radius and an initial density profile for the spherical dust particles are given and the charge and the density of the dust are calculated with an iterative method. During the transport of the dust, its charge is kept constant in time. The dust influences the electric field distribution through its charge and the density of the plasma through recombination of positive ions and electrons at its surface. In the model this process gives an extra production of silane radicals, since the growth of dust is

  16. Coagulation/Flocculation of Tannery Wastewater Using Immobilized Chemical Coagulants

    Directory of Open Access Journals (Sweden)

    Q. Imran

    2012-04-01

    Full Text Available Chemical coagulants were immobilized into bead form using sodium alginate to treat tannery wastewater samples. The used chemical coagulants were ammonium aluminium sulphate (NH4Al(SO42, aluminium sulphate (Al2(SO42, calcium carbonate (CaCO3, sodium citrate (Na3C6HsO7. The effect of the chemical coagulant dose and tannery wastewater pH was studied on wastewater electrical conductance (EC, total dissolved solids (TDS, sulphates, chlorides, phenolphthalein alkalinity, total alkalinity and chemical oxygen demand (COD. The quantity of various pollutants present in waste water was reduced after treatment. The optimized dose and pH for maximum decrease in EC and TDS were 5g/L and 7, respectively. The maximum reduction in the amount of sulphates and chlorides present in tannery wastewater was observed at dosage of 0.5g/L and pH 7. A dosage of 5g/L and pH 7 was also found most favorable for maximum reduction in values of COD, phenolphtalein and total alkalinity. The chromium concentrations in tannery wastewater before and after treatment were determined by atomic absorption spectrophotometer. A reduction in chromium concentration was observed after treatment. The promising results of the present study demonstrate that immobilization of chemical coagulants can make them more effective for wastewater treatment.

  17. High-resolution measurement, line identification, and spectral modeling of the K{beta} spectrum of heliumlike argon emitted by a laser-produced plasma using a gas-puff target

    Energy Technology Data Exchange (ETDEWEB)

    Skobelev, I.Y.; Faenov, A.Y.; Dyakin, V.M. [Multicharged Ion Spectra Data Center, VNIIFTRI, Mendeleevo, 141570 (Russia); Fiedorowicz, H.; Bartnik, A.; Szczurek, M. [Institute of Optoelectronics, Military University of Technology, 01-489 Warsaw (Poland); Beiersdorfer, P.; Nilsen, J.; Osterheld, A.L. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    1997-03-01

    We present an analysis of the spectrum of satellite transitions to the He-{beta} line in ArXVII. High-resolution measurements of the spectra from laser-heated Ar-gas-puff targets are made with spectral resolution of 10000 and spatial resolution of better than 50 {mu}m. These are compared with tokamak measurements. Several different lines are identified in the spectra and the spectral analysis is used to determine the plasma parameters in the gas-puff laser-produced plasma. The data complement those from tokamak measurements to provide more complete information on the satellite spectra. {copyright} {ital 1997} {ital The American Physical Society}

  18. Heat Transfer During Evaporation of Cesium From Graphite Surface in an Argon Environment

    Directory of Open Access Journals (Sweden)

    Bespala Evgeny

    2016-01-01

    Full Text Available The article focuses on discussion of problem of graphite radioactive waste formation and accumulation. It is shown that irradiated nuclear graphite being inalienable part of uranium-graphite reactor may contain fission and activation products. Much attention is given to the process of formation of radioactive cesium on the graphite element surface. It is described a process of plasma decontamination of irradiated graphite in inert argon atmosphere. Quasi-one mathematical model is offered, it describes heat transfer process in graphite-cesium-argon system. Article shows results of calculation of temperature field inside the unit cell. Authors determined the factors which influence on temperature change.

  19. Clinical periodontics with the argon laser

    Science.gov (United States)

    Finkbeiner, R. L.

    1995-04-01

    The argon laser has proven to be a valuable tool for the thermodynamic debridement of the periodontal lesion, incisions and tissue fusion. Illustrations of clinical applications and discussion of laser parameters will be provided.

  20. Microwave diagnostics of atmospheric plasmas

    Science.gov (United States)

    Scott, David

    Plasma treatment of biological tissues has tremendous potential due to the wide range of applications. Most plasmas have gas temperatures which greatly exceed room temperature. These are often utilized in electro-surgery for cutting and coagulating tissue. Another type of plasma, referred to as cold atmospheric plasma, or CAP, is characterized by heavy particle temperatures which are at or near room temperature. Due to this lack of thermal effect, CAP may provide less invasive medical procedures. Additionally, CAP have been demonstrated to be effective at targeting cancer cells while minimizing damage to the surrounding tissue. A recently fabricated Microwave Electron Density Device (MEDD) utilizes microwave scattering on small atmospheric plasmas to determine the electron plasma density. The MEDD can be utilized on plasmas which range from a fraction of a millimeter to several centimeters at atmospheric pressure when traditional methods cannot be applied. Microwave interferometry fails due to the small size of the plasma relative to the microwave wavelength which leads to diffraction and negligible phase change; electrostatic probes introduce very strong perturbation and are associated with difficulties of application in strongly-collisional atmospheric conditions; and laser Thomson scattering is not sensitive enough to measure plasma densities less than 1012 cm-3. The first part of this dissertation provides an overview of two types of small atmospheric plasma objects namely CAPs and plasmas utilized in the electro-surgery. It then goes on to describe the fabrication, testing and calibration of the MEDD facility. The second part of this dissertation is focused on the application of the MEDD and other diagnostic techniques to both plasma objects. A series of plasma images that illustrate the temporal evolution of a discharge created by an argon electrosurgical device operating in the coagulation mode and its behavior was analyzed. The discharge of the argon

  1. 活化血浆凝固时间对评价血小板输注疗效价值的研究%Clinical Value of Activated Plasma Coagulation Time on Evaluation of Platelet Transfusion

    Institute of Scientific and Technical Information of China (English)

    陈明艳; 邱群芳; 席雅娟; 彭友堂

    2014-01-01

    Objective:To study the value of activated plasma coagulation time ( APCT) on evaluation of platelet transfusion.Method:Patients with blood disease and blood platelets count (PLT) was less than 50× 109 L-1 in our hospital from January to December 2011 were selected,in which 34 hemorrhage patients were selected as the observation group , and 34 patients without hemorrhage were selected as the control group . PLT,APCT of two groups were detected ,platelet transfusion was adopted in patients whose PLT was less than 10×109L-1,detected APCT,PLT after anticoagulation,then calculated corrected count increment (CCI) and practical platelet recovery (PPR).Result:There were three patients adopted platelet transfusion ,difference of PLT≤20×109L-1 and PLT≤10×109L-1 in hemorrhage patients had no statistical significance (p>0.05), APCT had shortened compared to that before platelet transfusion ,difference was statistically signficant ( p<0. 01);in observation group platelet transfusion was effective in 29 patients,APCT was less than 80s after 24h, CCI of 2 patients and PPR of 5 patients met the invalid standard of platelet transfusion ,in addition,platelet transfusion of 5 patients was invalid,APCT was more than 80s after 24h ,only 2 patients’ CCI and PPR metthe invalid standard of platelet transfusion .Conclusion:ACT not only can show the number and quality chan-ges of blood platelet well , but also evaluate the efficacy of platelet transfusion more comprehensively .%目的:对用活化血浆凝固时间( APCT)评价血小板输注疗效的价值进行研究。方法:在2011年1月至12月于我院住院治疗的血小板计数(PLT)均<50×109L-1的血液病患者中,出血的患者34例为观察组,不出血34例为对照组。对两组患者静脉采血测PLT、APCT;再对观察组和对照组中PLT <10×109L-1的患者给予血小板输注,抗凝后测其APCT、PLT,并计算校正血小板增高指数(CCI)和实际血小板回收率

  2. Argon Laser Photoablation for Postburn Conjunctival Pigmentation

    Directory of Open Access Journals (Sweden)

    Seong Joon Ahn

    2014-01-01

    Full Text Available We report a case of an ocular burn injury from boiling water which resulted in conjunctival pigmentation, 1 week following injury. For cosmetic purposes, 2 sessions of argon laser photoablation were performed. One month after laser treatment, conjunctival pigmentation had been successfully removed and the patient was very satisfied with the results. Argon laser photoablation may be an effective way to remove postburn conjunctival pigmentation.

  3. Potassium-argon/argon-40-argon-39 geochronology of Cenozoic alkali basalts from the South China Sea

    Institute of Scientific and Technical Information of China (English)

    YAN Quanshu; SHI Xuefa; YANG Yaomin; WANG Kunshan

    2008-01-01

    Based on the isotopic chronologic results of Cenozoic alkali basalts from the South China Sea,the characteristics of volcanic activi-ty of the South China Sea after spreading were studied.The potassium - argon ages of eight alkali basalt samples from the South China Sea,and the argon - argon ages of two samples among them are reported.Apparent ages of the whole rock are 3.80 to 7.91 Ma with an average value of 5.43 Ma (potassium- argon,whole rock),and there is little difference among samples at the same location,e.g.,4.76~5.78 Ma for location S04-12.The argon - argon ages for the two samples are 6.06 and 4.71 Ma,which lie within the age scope of potassium - argon method.The dating results indicate that rock-forming age is from late Miocene to Pli-ocene,which is consistent with erupting event for alkali basalts from adjacent regions of the South China Sea.Volcanic activities occur after the cessation of spreading of the South China Sea,which are controlled by lithospheric fault and the spreading center formed during the spreading period of the South China Sea.These dating results,combined with geochemical characteristics of these basalts,the published chronological data for the South China Sea and its adjacent regions,and the updated geophysical data near Hainan Island,suggest that after the cessation of spreading of the South China Sea,there occur widely distributing magmatic activities which primarily is alkali basalt,and the volcanic activity continues to Quaternary.The activity may be relative to Hainan mantle plume originated from core/mantle boundary.

  4. Blood coagulation and the risk of atherothrombosis: a complex relationship

    Directory of Open Access Journals (Sweden)

    van der Voort Danielle

    2004-12-01

    Full Text Available Abstract The principles of Virchov's triad appear to be operational in atherothrombosis or arterial thrombosis: local flow changes and particularly vacular wall damage are the main pathophysiological elements. Furthermore, alterations in arterial blood composition are also involved although the specific role and importance of blood coagulation is an ongoing matter of debate. In this review we provide support for the hypothesis that activated blood coagulation is an essential determinant of the risk of atherothrombotic complications. We distinguish two phases in atherosclerosis: In the first phase, atherosclerosis develops under influence of "classical" risk factors, i.e. both genetic and acquired forces. While fibrinogen/fibrin molecules participate in early plaque lesions, increased activity of systemic coagulation is of no major influence on the risk of arterial thrombosis, except in rare cases where a number of specific procoagulant forces collide. Despite the presence of tissue factor – factor VII complex it is unlikely that all fibrin in the atherosclerotic plaque is the direct result from local clotting activity. The dominant effect of coagulation in this phase is anticoagulant, i.e. thrombin enhances protein C activation through its binding to endothelial thrombomodulin. The second phase is characterized by advancing atherosclerosis, with greater impact of inflammation as indicated by an elevated level of plasma C-reactive protein, the result of increased production influenced by interleukin-6. Inflammation overwhelms protective anticoagulant forces, which in itself may have become less efficient due to down regulation of thrombomodulin and endothelial cell protein C receptor (EPCR expression. In this phase, the inflammatory drive leads to recurrent induction of tissue factor and assembly of catalytic complexes on aggregated cells and on microparticles, maintaining a certain level of thrombin production and fibrin formation. In advanced

  5. [Ratio of erythrocyte and plasma in massive blood transfusion].

    Science.gov (United States)

    Wen, Xian-Hui; Liu, Feng-Xia; Zhang, Jun-Hua; Gui, Rong

    2014-06-01

    This study was purposed to explore the suitable ratio between fresh frozen plasma and erythrocyte by retrospective analysis of coagulation in patients with massive blood transfusion. The clinical data of 151 cases with massive blood transfusion from January 2011 to January 2013 were analyzed retrospectively. According to coagulation, patients were divided into coagulation normal group (138 cases) and coagulation dysfunction group (13 cases). Based on the ratio of 1:1 of fresh frozen plasma and erythrocyte, the patients were divided into high plasma group(2:1), medium plasma group (1:1) and low plasma (transfusion. The results showed that prothrombin time (PT), activated partial thromboplastin time (APTT) and thrombin time (TT) were prolonged, fibrinogen (FIB) level decreased significantly (all P transfusion 24 h; the high plasma and the medium plasma group of coagulation normal group had no significant changes in coagulation (P > 0.05); prothrombin time, activated partial thromboplastin time, thrombin time and fibrinogen level in the medium plasma and low plasma subgroup of coagulation dysfunction group after massive transfusion was still in abnormal levels (P > 0.05), coagulation function in high plasma subgroup was improved significantly (P transfusion, the ratio between fresh frozen plasma and erythrocyte is recommended to be 2:1 in patients of coagulation dysfunction in order to improve the patient's coagulation function and to reduce the incidence of adverse event, the ratio of fresh frozen plasma to erythrocyte is recommended to be 1:1 in patients with normal coagulation so as to reduce the dilutional coagulopathy and hypervolemia of blood.

  6. Fast-imaging and spectroscopic analysis of atmospheric argon streamers for large gap arc breakdown

    Science.gov (United States)

    Pachuilo, Michael; Stefani, Francis; Bengtson, Roger; Raja, Laxminarayan

    2014-10-01

    A non-equilibrium plasma source has been developed to assist in the low-voltage arc breakdown of large electrode gaps. The source consists of a dielectric embedded wire helically wound around a confining cylindrical quartz chamber. Annular electrodes cap the ends of the quartz chamber. An argon feed gas is used to provide a uniform environment and exhausts to ambient atmospheric conditions. A negative polarity 50 kV trigger pulse is applied to the embedded trigger wire to initiate the arc breakdown. Application of the trigger pulse produces a localized coronal discharges along the inner surface of the quartz tube. The corona provides seed electrons through which streamers propagate from one of the main discharge electrode along the quartz surface until it reaches the opposite electrode to bridge the gap. Once the gap is bridged a spark over occurs and robust arc discharge is formed in the chamber volume. Fast imaging of the streamer propagation establishes its velocity in the range of ~ 100 km/s. Spectroscopy of the streamer discharge in atmospheric argon has been conducted and electron temperature and number density estimated from a collision radiative model. Argon spectrum is dominated by neutral argon lines in the 650--950 nm range, and singly ionized argon lines are observed in the ultra-violet to near UV (300--400 nm). Research was performed in connection with AFOSR Contract FA9550-11-1-0062.

  7. Argon Collection And Purification For Proliferation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Achey, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event was a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.

  8. [Abnormality of blood coagulation indexes in patients with de novo acute leukemia and its clinical significance].

    Science.gov (United States)

    Xiao, Fang-Fang; Hu, Kai-Xun; Guo, Mei; Qiao, Jian-Hui; Sun, Qi-Yun; Ai, Hui-Sheng; Yu, Chang-Lin

    2013-04-01

    To explore hemorrhage risk and the clinical significance of abnormal change of prothrombin time (PT), activated partial thromboplastin time (APTT), plasma fibrinogen (FIB), plasma thrombin time (TT) and d-dimer (D-D) in de novo acute leukemia (except for APL), the different bleeding manifestations of 114 cases of de novo acute leukemia with different coagulation indexes were analyzed retrospectively. The correlation between these blood coagulation indexes and the possible correlative clinical characteristics were analysed, including age, sex, type of acute leukemia, initial white blood cell(WBC) and platelet(Plt) count, the proportion of blast cells in bone marrow and cytogenetic abnormality of patients at diagnosis. The results indicated that the incidence of abnormal blood coagulation was as high as 78.1% for de novo AL patients. These patients with 5 normal blood coagulation indexes may have mild bleeding manifestation, but the more abnormal indexes, the more severe bleeding. Both PT and D-D were sensitive indexes for diagnosis of level II bleeding. Incidence of abnormal blood coagulation significantly correlates with the proportion of blast cells in bone marrow (χ(2) = 4.184, OR = 1.021, P coagulation. It is concluded that the coagulation and fibrinolysis are abnormal in most patients with de novo acute leukemia. More abnormal indexes indicate more severe bleeding, and both PT and D-D are sensitive indexes for diagnosis of level II bleeding. Higher proportion of blast cells in bone marrow predicts higher incidence of abnormal blood clotting. Acute leukemia with elderly age, high white blood cell count and adverse cytogenetics do not predict severer abnormal blood clotting. Detection of PT, APTT, TT, FIB, and D-D may help to judge whether the patients are in a state of hypercoagulability or disseminated intravenous coagulation, which will provide experiment evidences for early intervention and medication.

  9. Attenuation of vacuum ultraviolet light in liquid argon

    CERN Document Server

    Neumeier, A; Oberauer, L; Potzel, W; Schönert, S; Dandl, T; Heindl, T; Ulrich, A; Wieser, J

    2015-01-01

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  10. Dependence of Arc Plasma Dispersion Capability on its Temperature

    Institute of Scientific and Technical Information of China (English)

    CHEN Yun-Yun; SONG Yang; HE An-Zhi; LI Zhen-Hua

    2008-01-01

    @@ The relationship between the dispersion capability and the temperature of argon arc plasma at Iatm is deduced in view of the plasma's refractive index equation.The results indicate that argon arc plasma has a normal dispersion and its dispersion capability is nonlinear to the plasma's temperature in a wide range of temperature and wavelength region.According to the results of numerical calculation, the preferred optical methods are believed to be suitable for the diagnosis of argon arc plasma in different temperature regions.

  11. Effect of fibrinogen on blood coagulation detected by optical coherence tomography

    Science.gov (United States)

    Xu, Xiangqun; Teng, Xiangshuai

    2015-05-01

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d1/e) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0-8 g L-1) and 2) native plasma with commercial Fbg added (0-8 g L-1). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels.

  12. Comparison of coagulation performance and floc properties using a novel zirconium coagulant against traditional ferric and alum coagulants.

    Science.gov (United States)

    Jarvis, Peter; Sharp, Emma; Pidou, Marc; Molinder, Roger; Parsons, Simon A; Jefferson, Bruce

    2012-09-01

    Coagulation in drinking water treatment has relied upon iron (Fe) and aluminium (Al) salts throughout the last century to provide the bulk removal of contaminants from source waters containing natural organic matter (NOM). However, there is now a need for improved treatment of these waters as their quality deteriorates and water quality standards become more difficult to achieve. Alternative coagulant chemicals offer a simple and inexpensive way of doing this. In this work a novel zirconium (Zr) coagulant was compared against traditional Fe and Al coagulants. The Zr coagulant was able to provide between 46 and 150% lower dissolved organic carbon (DOC) residual in comparison to the best traditional coagulant (Fe). In addition floc properties were significantly improved with larger and stronger flocs forming when the Zr coagulant was used with the median floc sizes being 930 μm for Zr; 710 μm for Fe and 450 μm for Al. In pilot scale experiments, a similar improved NOM and particle removal was observed. The results show that when optimised for combined DOC removal and low residual turbidity, the Zr coagulant out-performed the other coagulants tested at both bench and pilot scale.

  13. 氩气低温等离子体处理HDPE薄膜表面的性能研究%Study on Surface Modification of High Density Polyethylene ( HDPE ) Film by Low Temperature Plasma Treatment of Argon

    Institute of Scientific and Technical Information of China (English)

    王建龙; 王正祥; 解林坤; 顾丽争

    2012-01-01

    The surface of high density polyethylene was modified using low temperature Ar plasma technology under the condition of vacuum pressure of 20 Pa and treatment power of 30 W. The results have been analyzed and characterized with water contact angle measurement, scanned electron microscopy(SEM), atomic force microscopy(AFM), XPS, etc. The results show that the weight loss rate of per unit area has reached maximum value at discharge time of 90 seconds during the treatment time of 0 -300 s; the water contact angle sharply decreased in the 0 - 160 s treatment time and their values did not cause significant changes during the 160 -300 s treatment time; the water contact angle gradually increased with the longer standing time; the surface of HDPE could form some polar species such as carbonyl, hydroxyl and carboxyl groups and the binding energy of the surface changed after treatment by low temperature Ar plasma.%利用低温等离子体,以氩气为工作气体,在工作压强为20Pa、处理功率为30w的条件下对HDPE薄膜进行了表面改性。用接触角、SEM、AFM、XPS等手段对改性结果进行了分析和表征。研究结果表明:在0~300s的处理时间内,失重率在处理时间为90s左右时达最大值;接触角在0~160s内随处理时间的增加显著减小,而在160~300s的处理时间内没有发生明显变化;改性后的接触角随着放置时间的推移出现微弱回复;HDPE薄膜经过氩气低温等离子体处理后,能在其表面形成各种极性基团,主要是羰基、羟基和羧基,且薄膜经处理后,其表面的结合能及平面光洁度发生了改变。

  14. Optical emission spectrometric determination of arsenic and antimony by continuous flow chemical hydride generation and a miniaturized microwave microstrip argon plasma operated inside a capillary channel in a sapphire wafer

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, Pawel; Zapata, Israel Jimenez; Bings, Nicolas H. [Universitaet Hamburg, Institut fuer Anorganische und Angewandte Chemie, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Voges, Edgar [Universitaet Dortmund, Fakultaet fuer Elektrotechnik und Informationstechnik, Friedrich-Woehler-Weg 4, D-44221 Dortmund (Germany); Broekaert, Jose A.C. [Universitaet Hamburg, Institut fuer Anorganische und Angewandte Chemie, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)], E-mail: jose.broekaert@chemie.uni-hamburg.de

    2007-05-15

    Continuous flow chemical hydride generation coupled directly to a 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma operated inside a capillary channel in a sapphire wafer has been optimized for the emission spectrometric determination of As and Sb. The effect of the NaBH{sub 4} concentration, the concentration of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} used for sample acidification, the Ar flow rate, the reagent flow rates, the liquid volume in the separator as well as the presence of interfering metals such as Fe, Cu, Ni, Co, Zn, Cd, Mn, Pb and Cr, was investigated in detail. A considerable influence of Fe(III) (enhancement of up to 50 %) for As(V) and of Fe(III), Cu(II) and Cr(III) (suppression of up to 75%) as well as of Cd(II) and Mn(II) (suppression by up to 25%) for Sb(III) was found to occur, which did not change by more than a factor of 2 in the concentration range of 2-20 {mu}g ml{sup -1}. The microstrip plasma tolerated the introduction of 4.2 ml min{sup -1} of H{sub 2} in the Ar working gas, which corresponded to an H{sub 2}/Ar ratio of 28%. Under these conditions, the excitation temperature as measured with Ar atom lines and the electron number density as determined from the Stark broadening of the H{sub {beta}} line was of the order of 5500 K and 1.50 . 10{sup 14} cm{sup -3}, respectively. Detection limits (3{sigma}) of 18 ng ml{sup -1} for As and 31 ng ml{sup -1} for Sb were found and the calibration curves were linear over 2 orders of magnitude. With the procedure developed As and Sb could be determined at the 45 and 6.4 {mu}g ml{sup -1} level in a galvanic bath solution containing 2.5% of NiSO{sub 4}. Additionally, As was determined in a coal fly ash reference material (NIST SRM 1633a) with a certified concentration of As of 145 {+-} 15 {mu}g g{sup -1} and a value of 144 {+-} 4 {mu}g g{sup -1} was found.

  15. Monte Carlo simulation of electron back diffusion in argon

    Science.gov (United States)

    Radmilović, M.; Stojanović, V.; Petrović, Z. Lj.

    1999-10-01

    Monte Carlo simulation was applied to study the back-diffusion of electrons in argon at low and moderate values of E/N from 10Td to 10 kTd. Simulations were performed for gaps of 1 cm and for pressures corresponding to the breakdown voltages taken from experimental Paschen curves. Effects of inelastic collisions, ionization, reflection of electrons and anisotropic scattering as well as anisotropic initial and reflected angular distributions of electrons were included. A complete and detailed set of electron scattering cross sections that describes well electron transport in argon was used. We found a very good agreement of the results of simulations with the experimental data for well defined initial conditions, and with several models available in the literature.(A.V. Phelps and Z.LJ. Petrović), Plasma Sources Sci. Tehnol. 8, R21 (1999). While effect of reflection may be large, for realistic values of reflection coefficient and for realistic secondary electron productions the effect may be neglected for the accuracy required in gas discharge modeling.

  16. THE EFFECT OF PLASMA TREATMENT OVER THE ADHESION PROPERTY OF POLYAMİDE 6 FABRICS

    OpenAIRE

    ÖZDOĞAN, Esen

    2006-01-01

    The effect of plasma treatment on the surface characteristics of polyamide fabrics was investigated. Plasma surface modifications with carbon dioxide and argon were performed on the polyamide 6 fabrics to improve the adhesion and hidrophylity. The surface morphology of the fiber was observed with scanning electron microscopy. The fiber surface was effectively etched with carbon dioxide and argon plasma treatment

  17. ICARUS and status of liquid argon technology

    CERN Document Server

    Menegolli, Alessandro

    2012-01-01

    ICARUS T600 is the largest liquid Argon Time Projection Chamber (LAr TPC) detector ever realized. It operates underground at the LNGS laboratory in Gran Sasso. It has been smoothly running since summer 2010, collecting data with the CNGS (Cern to Gran Sasso) beam and with cosmic particles. Liquid Argon TPCs are indeed 'electronic bubble chambers', providing a completely uniform imaging calorimetry with unprecedented accuracy on such massive volumes. ICARUS T600 is internationally considered as a milestone towards the realization of the next generation of massive detectors (tens of ktons) for neutrino and rare event physics. Results will be presented on the data collected so far with the detector.

  18. Coagulation factor Xa signaling : the link between coagulation and inflammatory bowel disease?

    NARCIS (Netherlands)

    Borensztajn, Keren; Peppelenbosch, Maikel P.; Spek, C. Arnold

    2009-01-01

    Inflammatory bowel disease (IBD) is characterized by activation of the coagulation cascade and it has long been suspected that coagulation is an essential component of this still largely idiopathic group of diseases. The realization that coagulation factors are not only passive mediators in the prop

  19. New evidence for intrinsic blood coagulation in chickens.

    Science.gov (United States)

    Doerr, J A; Hamilton, P B

    1981-01-01

    Coagulation of blood in chickens is considered the result of an extrinsic clotting system initiated, as in mammals, by tissue thromboplastin released from injured tissues. Blood coagulation in mammals depends principally on an intrinsic mechanism in which thromboplastin is generated from blood itself. Only a negligible role, if any, has been ascribed to an intrinsic system in chickens. A reevaluation of intrinsic coagulation in chickens was undertaken in this study. Whole blood of chickens was found to clot over 30% faster when contacted by suitable surface activators such as kaolin or glass than when such contact was omitted. Plasma recalcification times were significantly (P less than .02) shortened by contact activators. Clotting functions were measurable both by partial thromboplastin time and activated partial thromboplastin time, tests that bypass extrinsic factors. Intrinsic thromboplastin could be generated from dilute whole chicken blood although at a slower rate than that reported for human blood. Modification of whole blood thromboplastin generation techniques permitted measurement of activities that seem analogous to human intrinsic factors VIII and IX but not XI or XII. These data provide evidence of a functioning intrinsic clotting mechanism in chickens. A complete description and role for this mechanism remains to be defined.

  20. Influence of argon and oxygen on charge-state-resolved ion energydistributions of filtered aluminum arcs

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, Johanna; Anders, Andre; Mraz, Stanislav; Atiser, Adil; Schneider, Jochen M.

    2006-03-23

    The charge-state-resolved ion energy distributions (IEDs) in filtered aluminum vacuum arc plasmas were measured and analyzed at different oxygen and argon pressures in the range 0.5 8.0 mTorr. A significant reduction of the ion energy was detected as the pressure was increased, most pronounced in an argon environment and for the higher charge states. The corresponding average charge state decreased from 1.87 to 1.0 with increasing pressure. The IEDs of all metal ions in oxygen were fitted with shifted Maxwellian distributions. The results show that it is possible to obtain a plasma composition with a narrow charge-state distribution as well as a narrow IED. These data may enable tailoring thin-film properties through selecting growth conditions that are characterized by predefined charge state and energy distributions.

  1. Positive and negative pulsed corona in argon

    NARCIS (Netherlands)

    Veldhuizen, E.M. van; Rutgers, W.R.; Ebert, U.

    2002-01-01

    Photographs are obtained of corona discharges in argon at atmospheric pressure using a high resolution, intensified CCD camera. Positive and negative polarity is applied at the curved electrode in a point-plane gap and a plane-plane gap with a protruding point. Branching is observed in the positive

  2. Inflammation and coagulation in urticaria and angioedema.

    Science.gov (United States)

    Cugno, Massimo; Asero, Riccardo; Tedeschi, Alberto; Lazzari, Riccardo; Marzano, Angelo V

    2012-09-01

    Urticaria is a skin disease characterised by short-lived surface swellings of the dermis (wheals) frequently accompanied by itching. It is classified as acute or chronic depending on whether the wheal recurrence occurs for less or more than six weeks. Acute urticaria is often due to a hypersensitivity reaction, whereas about 50% of the cases of chronic urticaria are regarded as autoimmune. Urticaria may occur alone or in association with a deeper swelling (angioedema) involving the subcutaneous and/or submucosal tissues, and last from hours to a few days. Angioedema can also develop alone, and may be idiopathic or be caused by allergies, inherited or acquired deficiencies of C1-inhibitor protein, or adverse drug reactions. An interplay between inflammation and coagulation has been proposed as a pathomechanism in urticaria and urticaria-associated angioedema (in which histamine and thrombin are involved), as well as in angioedema due to C1-inhibitor deficiency, which involves various biological systems. An increase in the plasma markers of thrombin generation, fibrinolysis and inflammation has been documented during exacerbations of urticaria and angioedema, with the marker levels decreasing to normal during remission. However, the hypercoagulable state in chronic urticaria and angioedema has not been reported to be associated with any increased risk of thrombosis, although there have been a number of reports of cardiovascular events occurring during episodes of acute urticaria. These observations have provided the rationale for the clinical evaluation of anticoagulant and antifibrinolytic drugs, the efficacy of which has sometimes been demonstrated.

  3. Blood coagulation reactions on nanoscale membrane surfaces

    Science.gov (United States)

    Pureza, Vincent S.

    Blood coagulation requires the assembly of several membrane-bound protein complexes composed of regulatory and catalytic subunits. The biomembranes involved in these reactions not only provide a platform for these procoagulant proteins, but can also affect their function. Increased exposure of acidic phospholipids on the outer leaflet of the plasma membrane can dramatically modulate the catalytic efficiencies of such membrane-bound enzymes. Under physiologic conditions, however, these phospholipids spontaneously cluster into a patchwork of membrane microdomains upon which membrane binding proteins may preferentially assemble. As a result, the membrane composition surrounding these proteins is largely unknown. Through the development and use of a nanometer-scale bilayer system that provides rigorous control of the phospholipid membrane environment, I investigated the role of phosphatidylserine, an acidic phospholipid, in the direct vicinity (within nanometers) of two critical membrane-bound procoagulant protein complexes and their respective natural substrates. Here, I present how the assembly and function of the tissue factor˙factor VIIa and factor Va˙factor Xa complexes, the first and final cofactor˙enzyme complexes of the blood clotting cascade, respectively, are mediated by changes in their immediate phospholipid environments.

  4. SC response characteristics of two kinds of coagulant

    Institute of Scientific and Technical Information of China (English)

    杨万东; 宋爽; 史惠祥

    2002-01-01

    Automatic coagulant dosage control with streaming current (SC) technique is introduced in this paper. Aluminum and ferric coagulants are widely used in surface water treatment. The SC response characteristics of P-AlCl3 aluminum coagulant and P-FeCl3 ferric coagulant were investigated in this work. Bench-scale water treatment results were obtained from jar tests including rapid mixing, flocculation and undisturbed sedimentation. Results showed that aluminum coagulant is more sensitive than ferric coagulant to SC response.

  5. SC response characteristics of two kinds of coagulant

    Institute of Scientific and Technical Information of China (English)

    杨万东; 宋爽; 史惠祥

    2002-01-01

    Automatic coagulant dosage control with streaming current (SC) technique is in troduced inthis paper. Aluminum and ferric coagulants are widely used in surface water treatment. The SC response characteristics of P-AiCI3 aluminum coagulant and P-FeCI3 ferric coagulant were investigated in this work. Bench-scale water treatment results were obtained from jar tests including rapid mixing,flocculation and undisturbed sedimentation. Results showed that aluminum coagulant is more sensitive than ferric coagulant to SC response.

  6. Influence Factor Analysis on Jet Length of Atmospheric Pressure Argon Plasma Jets%大气压氩气等离子体射流长度的影响因素

    Institute of Scientific and Technical Information of China (English)

    张冠军; 詹江杨; 邵先军; 彭兆裕

    2011-01-01

    Atmospheric pressure Ar plasma jets(APPJs) were designed to research their discharge characteristics with three kinds of different jet configurations,i.e.,double wrapped electrode,single wrapped electrode and center-electrode inside tube.The influences of flow rates,applied voltage amplitudes,and electrode configurations on the length of APPJs were studied.The results show that,as the flow rates increase,the flow status of Ar in tube has a process from the laminar state to the transition state and finally to the turbulent state.Correspondingly,the jet length first increases,then decreases,and finally reaches the maximum length when the Reynolds number is around 2000~3000.Under the same gas flow rate,the length of the single-wrapped electrode jet is slightly longer than double wrapped electrode jet while the center-electrode jet is shortest among three electrode configurations.But the discharge stability of center-electrode jet is superior to that of double-wrapped electrode jet,and the single-wrapped electrode jet is the worst.It is generally believed that the length of the jets is based on the high-energy electron in the ionization head.The electric field of double-wrapped electrode jet and single-wrapped electrode jet is mainly axial component of electric field,which leads to the discharge similar to streamer discharge and prolongs the APPJ length,while the electric field of the center-electrode jet is concentrated at the peak of the center electrode,and the discharge is originated from corona discharge with short jet length.The jet length comparison of different tube sizes shows that under our paper's conditions,the maximum jet length of the double-electrode jet and single-electrode jet first increases with the increment of tube sizes and finally tends to saturation,while the maximum jet length of the centre-electrode jet slightly decreases.%为了研究不同大气压氩气射流结构的放电特性以及气流速率、外施电压和电极结构对射

  7. 46 CFR 151.50-36 - Argon or nitrogen.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Argon or nitrogen. 151.50-36 Section 151.50-36 Shipping... BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-36 Argon or nitrogen. (a) A cargo tank that contains argon or nitrogen and that has a maximum allowable working pressure of 172 kPa...

  8. Matriptase activation connects tissue factor-dependent coagulation initiation to epithelial proteolysis and signaling.

    Science.gov (United States)

    Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric

    2016-06-23

    The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation.

  9. Coagulation factor VA2440G causes east Texas bleeding disorder via TFPIα

    Science.gov (United States)

    Vincent, Lisa M.; Tran, Sinh; Livaja, Ruzica; Bensend, Tracy A.; Milewicz, Dianna M.; Dahlbäck, Björn

    2013-01-01

    The autosomal dominantly inherited east Texas bleeding disorder is linked to an A2440G variant in exon 13 of the F5 gene. Affected individuals have normal levels of coagulation factor V (FV) activity, but demonstrate inhibition of global coagulation tests. We demonstrated that the A2440G mutation causes upregulation of an alternatively spliced F5 transcript that results in an in-frame deletion of 702 amino acids of the large activation fragment, the B domain. The approximately 250-kDa FV isoform (FV-short), which can be fully activated by thrombin, is present in all A2440G carriers’ plasma (n = 16). FV-short inhibits coagulation through an indirect mechanism by forming a complex with tissue factor pathway inhibitor-α (TFPIα), resulting in an approximately 10-fold increase in plasma TFPIα, suggesting that the TFPIα:FV-short complexes are retained in circulation. The TFPIα:FV-short complexes efficiently inhibit thrombin generation of both intrinsic and extrinsic coagulation pathways. These data demonstrate that the east Texas bleeding disorder–associated F5A2440G leads to the formation of the TFPIα:FV-short complex, which inhibits activation and propagation of coagulation. PMID:23979162

  10. Coagulation factor V(A2440G) causes east Texas bleeding disorder via TFPIα.

    Science.gov (United States)

    Vincent, Lisa M; Tran, Sinh; Livaja, Ruzica; Bensend, Tracy A; Milewicz, Dianna M; Dahlbäck, Björn

    2013-09-01

    The autosomal dominantly inherited east Texas bleeding disorder is linked to an A2440G variant in exon 13 of the F5 gene. Affected individuals have normal levels of coagulation factor V (FV) activity, but demonstrate inhibition of global coagulation tests. We demonstrated that the A2440G mutation causes upregulation of an alternatively spliced F5 transcript that results in an in-frame deletion of 702 amino acids of the large activation fragment, the B domain. The approximately 250-kDa FV isoform (FV-short), which can be fully activated by thrombin, is present in all A2440G carriers' plasma (n = 16). FV-short inhibits coagulation through an indirect mechanism by forming a complex with tissue factor pathway inhibitor-α (TFPIα), resulting in an approximately 10-fold increase in plasma TFPIα, suggesting that the TFPIα:FV-short complexes are retained in circulation. The TFPIα:FV-short complexes efficiently inhibit thrombin generation of both intrinsic and extrinsic coagulation pathways. These data demonstrate that the east Texas bleeding disorder-associated F5(A2440G) leads to the formation of the TFPIα:FV-short complex, which inhibits activation and propagation of coagulation.

  11. Coagulation and fibrinolysis during laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Rahr, H B; Fabrin, K; Larsen, J F;

    1999-01-01

    Laparoscopic surgery appears to be less traumatic to the patient than open surgery, but its influence upon coagulation and fibrinolysis is incompletely elucidated. Our aim was to measure markers of coagulation and fibrinolysis before, during. and after laparoscopic cholecystectomy (LC). Blood...

  12. Investigation of coagulation activity of natural coagulants from seeds of different leguminose species

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2005-01-01

    Full Text Available The ability of seeds of plants: Phaseolus vulgaris, Robinia pseudoacacia Ceratonia siliqua and Amorpha fruticosa, to act as natural coagulants was tested using synthetic turbid water. This water was prepared by adding kaolin into tap water, just before the test. Active components were extracted from ground seeds with distilled water. The coagulation ability of this extract was assessed by the use of standard jar test measurements in water with various initial turbidity. Investigation of these natural coagulants was confirmed their positive coagulation activity. Of all plants that have been examined, the seed extract from Ceratonia siliqua appeared to be one of the most effective coagulants for water treatment. A dose of 20 mg/l of this coagulant resulted in 100% coagulation activity for clarification of water with 17.5 NTU initial turbidity.

  13. The hemostatic status of pediatric recipients of adult liver grafts suggests that plasma levels of hemostatic proteins are not regulated by the liver

    NARCIS (Netherlands)

    Lisman, Ton; Platto, Marco; Meijers, Joost C. M.; Haagsma, Elizabeth B.; Colledan, Michele; Porte, Robert J.

    2011-01-01

    Plasma levels of coagulation factors differ profoundly between adults and children, but are remarkably stable throughout adulthood. It is unknown which factors determine plasma levels of coagulation factors in a given individual. We hypothesized that the liver, which synthesizes coagulation factors,

  14. Textile wastewater purification through natural coagulants

    Science.gov (United States)

    Beltrán-Heredia, J.; Sánchez-Martín, J.; Rodríguez-Sánchez, M. T.

    2011-09-01

    A new coagulant obtained through polymerization of Acacia mearnsii de Wild tannin extract has been characterized in the removal of two dangerous dye pollutants: Alizarin Violet 3R and Palatine Fast Black WAN. This coagulant is lab-synthesized according to the etherification of tannins with glycidyltrimethylammonium chloride and formaldehyde and its performance in dye removal in terms of efficiency was high. Reasonably low coagulant dosages (ca. 50 mg L-1) reaches high capacity levels (around 0.8 for Alizarin Violet 3R and 1.6 for Palatine Fast Black WAN mg dye mg-1 of coagulant) and pH and temperature are not extremely affecting variables. The systems coagulant dyes were successfully modeled by applying the Langmuir hypothesis. q max and b parameters were obtained with an adjusted correlation factor ( r 2) above 0.8.

  15. Quantifying interspecific coagulation efficiency of phytoplankton

    DEFF Research Database (Denmark)

    Hansen, J.L.S.; Kiørboe, Thomas

    1997-01-01

    Non-sticky latex beads and sticky diatoms were used as models to describe mutual coagulation between sticky and non-sticky particles. in mixed suspensions of beads and Thalassiosira nordenskjoeldii, both types of particles coagulated into mixed aggregates at specific rates, from which the intersp......Non-sticky latex beads and sticky diatoms were used as models to describe mutual coagulation between sticky and non-sticky particles. in mixed suspensions of beads and Thalassiosira nordenskjoeldii, both types of particles coagulated into mixed aggregates at specific rates, from which....... nordenskjoeldii. Mutual coagulation between Skeletonema costatum and the non-sticky cel:ls of Ditylum brightwellii also proceeded with hall the efficiency of S. costatum alone. The latex beads were suitable to be used as 'standard particles' to quantify the ability of phytoplankton to prime aggregation...

  16. Atmospheric pressure argon surface discharges propagated in long tubes: physical characterization and application to bio-decontamination

    Science.gov (United States)

    Kovalova, Zuzana; Leroy, Magali; Jacobs, Carolyn; Kirkpatrick, Michael J.; Machala, Zdenko; Lopes, Filipa; Laux, Christophe O.; DuBow, Michael S.; Odic, Emmanuel

    2015-11-01

    Pulsed corona discharges propagated in argon (or in argon with added water vapor) at atmospheric pressure on the interior surface of a 49 cm long quartz tube were investigated for the application of surface bio-decontamination. H2O molecule dissociation in the argon plasma generated reactive species (i.e. OH in ground and excited states) and UV emission, which both directly affected bacterial cells. In order to facilitate the evaluation of the contribution of UV radiation, a DNA damage repair defective bacterial strain, Escherichia coli DH-1, was used. Discharge characteristics, including propagation velocity and plasma temperature, were measured. Up to ~5.5 and ~5 log10 reductions were observed for E. coli DH-1 bacteria (from 106 initial load) exposed 2 cm and 44 cm away from the charged electrode, respectively, for a 20 min plasma treatment. The factors contributing to the observed bactericidal effect include desiccation, reactive oxygen species (OH) plus H2O2 accumulation in the liquid phase, and UV-B (and possibly VUV) emission in dry argon. The steady state temperature measured on the quartz tube wall did not exceeded 29 °C the contribution of heating, along with that of H2O2 accumulation, was estimated to be low. The effect of UV-B emission alone or in combination with the other stress factors of the plasma process was examined for different operating conditions.

  17. Cell Adhesion to Plasma-Coated PVC

    OpenAIRE

    Elidiane C. Rangel; Souza,Eduardo S. de; Francine S. de Moraes; Eliana A. R. Duek; Carolina Lucchesi; Schreiner, Wido H.; Durrant, Steven F.; Cruz, Nilson C.

    2014-01-01

    To produce environments suitable for cell culture, thin polymer films were deposited onto commercial PVC plates from radiofrequency acetylene-argon plasmas. The proportion of argon in the plasmas, P-Ar, was varied from 5.3 to 65.8%. The adhesion and growth of Vero cells on the coated surfaces were examined for different incubation times. Cytotoxicity tests were performed using spectroscopic methods. Carbon, O, and N were detected in all the samples using XPS. Roughness remained almost unchang...

  18. A high-fat meal does not activate blood coagulation factor VII in minipigs

    DEFF Research Database (Denmark)

    Olsen, A K; Larsen, L F; Bladbjerg, E-M;

    2001-01-01

    , 3.5, 4, 5, and 6 h after the first fat load. Triglycerides, activated FVII (FVIIa), FVII coagulant activity (FVIIc), FVII amidolytic activity (FVIIam) and prothrombin fragment I + 2 (F1 + 2) were analysed in plasma samples. Median plasma triglycerides were significantly raised from 0.67 mmol....../l (baseline) to 2.56 mmol/l 5 h postprandially (P high-fat meal does not seem...

  19. Intein-Fused Lucine Zippers Increase Plasma Coagulation Activity by Improving Protein Trans-Splicing in Dual-Vector Factor Ⅷ Gene Delivered Mice%亮氨酸拉链提高小鼠血浆中剪接的凝血因子Ⅷ凝血活性

    Institute of Scientific and Technical Information of China (English)

    朱甫祥; 刘泽隆; 缪静; 屈慧鸽; 迟晓艳

    2012-01-01

    培养细胞实验表明,亮氨酸拉链通过改善内含肽(intein)的蛋白质剪接效率,提高双载体转B区缺失型凝血因子Ⅷ(BDD-FⅧ)基因细胞剪接FⅧ蛋白的分泌量和活性.本文从C57BL/6小鼠门静脉注射含亮氨酸拉链和Ssp DnaB内含肽融合的BDD-FⅧ的重链和轻链基因双表达载体,48 h后,检测到血浆的重链分泌量和FⅧ活性分别为(298±67) μg/L和(1.15±0.29) U/mL,明显高于不含亮氨酸拉链的双载体转BDD-FⅧ基因对照小鼠((179±59) μg/L和(0.58±0.19) U/mL).结果表明,亮氨酸拉链通过改善蛋白质反式剪接,提高基于蛋白质剪接的双载体转BDD-FⅧ基因小鼠血浆的凝血活性,为进一步双腺相关病毒(AAV)载体转BDD-FⅧ基因的甲型血友病基因治疗研究提供了依据.%We previously demonstrated that leucine zippers fused to intein could increase secretion of spliced B-domain-deleted coagulation factor Ⅷ (BDD-FⅧ) protein and activity by dual-vector based BDD-Ⅷ gene transfected cell in vitro through improving protein trans -splicing. In this study, a pair of plasmid vectors expressing human BDD-FⅧ heavy and light chain fused with lucine zipper and split Ssp DnaB intein was co-injected into C57BL/6 mice via the portal vein. Fourty-eight hours post-injection, the level of heavy chain and FⅧ coagulation activity in collected plasma were determined and shown as (298±67)μg/L and (1.15±0.29) U/ml respectively, greater than that of control mice injected with both vectors without leucine zippers ((179±59) μg/L and (0.58±0.19) U/ml). It demonstrated that leucine zippers fused intein could increase FⅧ coagulation activity in plasma of mice with intein-based dual-vector BDD-FⅧ gene delivery through improved protein trans -splicing. It provided evidence for ongoing hemophilia A gene therapy using dual-AAV vecors.

  20. Identification of the biologically active liquid chemistry induced by a nonthermal atmospheric pressure plasma jet.

    Science.gov (United States)

    Wende, Kristian; Williams, Paul; Dalluge, Joe; Gaens, Wouter Van; Aboubakr, Hamada; Bischof, John; von Woedtke, Thomas; Goyal, Sagar M; Weltmann, Klaus-Dieter; Bogaerts, Annemie; Masur, Kai; Bruggeman, Peter J

    2015-06-06

    The mechanism of interaction of cold nonequilibrium plasma jets with mammalian cells in physiologic liquid is reported. The major biological active species produced by an argon RF plasma jet responsible for cell viability reduction are analyzed by experimental results obtained through physical, biological, and chemical diagnostics. This is complemented with chemical kinetics modeling of the plasma source to assess the dominant reactive gas phase species. Different plasma chemistries are obtained by changing the feed gas composition of the cold argon based RF plasma jet from argon, humidified argon (0.27%), to argon/oxygen (1%) and argon/air (1%) at constant power. A minimal consensus physiologic liquid was used, providing isotonic and isohydric conditions and nutrients but is devoid of scavengers or serum constituents. While argon and humidified argon plasma led to the creation of hydrogen peroxide dominated action on the mammalian cells, argon-oxygen and argon-air plasma created a very different biological action and was characterized by trace amounts of hydrogen peroxide only. In particular, for the argon-oxygen (1%), the authors observed a strong negative effect on mammalian cell proliferation and metabolism. This effect was distance dependent and showed a half life time of 30 min in a scavenger free physiologic buffer. Neither catalase and mannitol nor superoxide dismutase could rescue the cell proliferation rate. The strong distance dependency of the effect as well as the low water solubility rules out a major role for ozone and singlet oxygen but suggests a dominant role of atomic oxygen. Experimental results suggest that O reacts with chloride, yielding Cl2(-) or ClO(-). These chlorine species have a limited lifetime under physiologic conditions and therefore show a strong time dependent biological activity. The outcomes are compared with an argon MHz plasma jet (kinpen) to assess the differences between these (at least seemingly) similar plasma sources.

  1. MeV Argon ion beam generation with narrow energy spread

    CERN Document Server

    Xu, Jiancai; Shen, Baifei; Zhang, Hui; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-01-01

    Laser driven particle acceleration has shown remarkable progresses in generating multi-GeV electron bunches and 10s of MeV ion beams based on high-power laser facilities. Intense laser pulse offers the acceleration field of 1012 Volt per meter, several orders of magnitude larger than that in conventional accelerators, enabling compact devices. Here we report that a highly-collimated argon ion beam with narrow energy spread is produced by irradiating a 45-fs fully-relativistic laser pulse onto an argon cluster target. The highly-charged (Argon ion with charge state of 16+) heavy ion beam has a minimum absolute energy spread of 0.19 MeV per nucleon at the energy peak of 0.39 MeV per nucleon. we identify a novel scheme from particle-in-cell simulations that greatly reduces the beam energy spread. The laser-driven intense plasma wakefield has a strong modulation on the ion beam in a way that the low energy part is cut off. The pre-accelerated argon ion beam from Coulomb explosion thus becomes more mono-energetic ...

  2. Enhanced coagulation for high alkalinity and micro-polluted water: the third way through coagulant optimization.

    Science.gov (United States)

    Yan, Mingquan; Wang, Dongsheng; Qu, Jiuhui; Ni, Jinren; Chow, Christopher W K

    2008-04-01

    Conventional coagulation is not an effective treatment option to remove natural organic matter (NOM) in water with high alkalinity/pH. For this type of water, enhanced coagulation is currently proposed as one of the available treatment options and is implemented by acidifying the raw water and applying increased doses of hydrolyzing coagulants. Both of these methods have some disadvantages such as increasing the corrosive tendency of water and increasing cost of treatment. In this paper, an improved version of enhanced coagulation through coagulant optimization to treat this kind of water is demonstrated. A novel coagulant, a composite polyaluminum chloride (HPAC), was developed with both the advantages of polyaluminum chloride (PACl) and the additive coagulant aids: PACl contains significant amounts of highly charged and stable polynuclear aluminum hydrolysis products, which is less affected by the pH of the raw water than traditional coagulants (alum and ferric salts); the additives can enhance both the charge neutralization and bridging abilities of PACl. HPAC exhibited 30% more efficiency than alum and ferric salts in dissolved organic carbon (DOC) removal and was very effective in turbidity removal. This result was confirmed by pilot-scale testing, where particles and organic matter were removed synergistically with HPAC as coagulant by sequential water treatment steps including pre-ozonation, coagulation, flotation and sand filtration.

  3. Neprilysin Inhibits Coagulation through Proteolytic Inactivation of Fibrinogen.

    Directory of Open Access Journals (Sweden)

    Matthew Burrell

    Full Text Available Neprilysin (NEP is an endogenous protease that degrades a wide range of peptides including amyloid beta (Aβ, the main pathological component of Alzheimer's disease (AD. We have engineered NEP as a potential therapeutic for AD but found in pre-clinical safety testing that this variant increased prothrombin time (PT and activated partial thromboplastin time (APTT. The objective of the current study was to investigate the effect of wild type NEP and the engineered variant on coagulation and define the mechanism by which this effect is mediated. PT and APTT were measured in cynomolgus monkeys and rats dosed with a human serum albumin fusion with an engineered variant of NEP (HSA-NEPv as well as in control plasma spiked with wild type or variant enzyme. The coagulation factor targeted by NEP was determined using in vitro prothrombinase, calibrated automated thrombogram (CAT and fibrin formation assays as well as N-terminal sequencing of fibrinogen treated with the enzyme. We demonstrate that HSA-NEP wild type and HSA-NEPv unexpectedly impaired coagulation, increasing PT and APTT in plasma samples and abolishing fibrin formation from fibrinogen. This effect was mediated through cleavage of the N-termini of the Aα- and Bβ-chains of fibrinogen thereby significantly impairing initiation of fibrin formation by thrombin. Fibrinogen has therefore been identified for the first time as a substrate for NEP wild type suggesting that the enzyme may have a role in regulating fibrin formation. Reductions in NEP levels observed in AD and cerebral amyloid angiopathy may contribute to neurovascular degeneration observed in these conditions.

  4. Coagulation abnormalities in the cirrhotic patient.

    Science.gov (United States)

    Muciño-Bermejo, Jimena; Carrillo-Esper, Raúl; Uribe, Misael; Méndez-Sánchez, Nahum

    2013-01-01

    The clotting process is a dynamic array of multiple processes which can be described in four phases: platelet plug initiation and formation, clotting process propagation by the coagulation cascade, clotting termination by antithrombotic mechanisms and clot removal by fibrinolysis. The liver plays a central role in each of these phases of clotting process, as it synthesizes the majority of coagulation factors and proteins involved in fibrinolysis as well as thrombopoeitin, which is responsible for platelet production from megakaryocytes. Many pathological processes associated with cirrhosis, such as portal hypertension and endothelial dysfunction, as well as co-morbid conditions, may also alter the coagulation process. Consequently, patients with liver disease have a disturbed balance of procoagulant and anti-coagulant factors which deviates from the normal coagulation cascade. This situation poses an additional problem in the diagnostic and therapeutic approach to this group of patients, since traditional coagulation test may not be reliable for assessing bleeding or thrombotic risk and traditional transfusional strategies may not be applicable in cirrhotic patients. In this article, we review the pathophysiological bases of coagulation abnormalities, in cirrhotic patients, the diagnostic therapeutic strategies to be followed and its impact on the clinical outcome in the cirrhotic patient.

  5. Detrapping of tungsten nanoparticles in a direct-current argon glow discharge

    Energy Technology Data Exchange (ETDEWEB)

    Couëdel, L., E-mail: lenaic.couedel@univ-amu.fr; Kumar, K. Kishor; Arnas, C. [Laboratoire de Physique des Interactions Ioniques et Moléculaires, CNRS, Aix-Marseille Université, 13397 Marseille (France)

    2014-12-15

    Nanoparticles are grown from the sputtering of a tungsten cathode in a direct current argon glow discharge. Laser light scattering of a vertical laser sheet going through the plasma reveals that the dust particle cloud is compressed and pushed towards the anode during the discharge. Scanning electron microscopy images of substrates exposed to the plasma for given durations show that dust particles are continuously falling down on the anode during the discharge. These observations are explained by the fact that the electrostatic force at the negative glow-anode sheath boundary cannot balance the ion drag, gravity, and thermophoresis forces for particles of more than a few tens of nanometres in diameter.

  6. Abnormal epidermal changes after argon laser treatment

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, R.A.; Knobler, R.M.; Aberer, E.; Klein, W.; Kocsis, F.; Ott, E. (Univ. of Vienna (Austria))

    1991-02-01

    A 26-year-old woman with a congenital port-wine stain on the forehead was treated three times at 2-month intervals with an argon laser. Six months after the last treatment, moderate blanching and mild scaling confined to the treated area was observed. A biopsy specimen of the treated area revealed a significant decrease in ectatic vessels. However, epidermal changes similar to those of actinic keratosis with disorganized cell layers and marked cytologic abnormalities were seen. Analysis of peripheral blood lymphocytes for a defect in DNA repair was negative. Multiple, argon laser-induced photothermal effects may be responsible for the changes observed in our case and may lead to premalignant epidermal transformation.

  7. Explanation of the memory effect in argon

    Directory of Open Access Journals (Sweden)

    Marković Vidosav

    2005-01-01

    Full Text Available Memory effect - the long time variation of the electrical breakdown time delay on the relaxation time td (τ was observed in argon 24 hours after relaxation times and explained by the long-lived metastable states remaining from the preceding glow. However, the quenching processes reducing the effective lifetime of metastable states several orders of magnitude below that relevant for the time scale of observation were neglected. By applying approximate gas phase models it was found that the early afterglow kinetics up to hundreds of milliseconds is dominated by the decay of molecular argon ions Ar2+ and the approximate value of their ambipolar diffusion coefficient is determined. After that, nitrogen atoms present as impurities and recombined on the cathode surface and/or field emission determine the breakdown time delay down to the cosmic rays and natural radioactivity level.

  8. ATLAS Liquid Argon Calorimeter Module Zero

    CERN Multimedia

    1993-01-01

    This module was built and tested with beam to validate the ATLAS electromagnetic calorimeter design. One original design feature is the folding. 10 000 lead plates and electrodes are folded into an accordion shape and immersed in liquid argon. As they cross the folds, particles are slowed down by the lead. As they collide with the lead atoms, electrons and photons are ejected. There is a knock-on effect and as they continue on into the argon, a whole shower is produced. The electrodes collect up all the electrons and this signal gives a measurement of the energy of the initial particle. The M0 was fabricated by French institutes (LAL, LAPP, Saclay, Jussieu) in the years 1993-1994. It was tested in the H6/H8 beam lines in 1994, leading to the Technical Design Report in 1996.

  9. Argon gas flow through glass nanopipette

    Science.gov (United States)

    Takami, Tomohide; Nishimoto, Kiwamu; Goto, Tadahiko; Ogawa, Shuichi; Iwata, Futoshi; Takakuwa, Yuji

    2016-12-01

    We have observed the flow of argon gas through a glass nanopipette in vacuum. A glass nanopipette with an inner diameter of 100 nm and a shank length of 3 mm was set between vacuum chambers, and argon gas was introduced from the top of the nanopipette to the bottom. The exit pressure was monitored with an increase in entrance pressure in the range of 50-170 kPa. Knudsen flow was observed at an entrance pressure lower than 100 kPa, and Poiseuille flow was observed at an entrance pressure higher than 120 kPa. The proposed pressure-dependent gas flow method provides a means of evaluating the glass nanopipette before using it for various applications including nanodeposition to surfaces and femtoinjection to living cells.

  10. Time-resolved characterization of a filamentary argon discharge at atmospheric pressure in a capillary using emission and absorption spectroscopy

    Science.gov (United States)

    Schröter, Sandra; Pothiraja, Ramasamy; Awakowicz, Peter; Bibinov, Nikita; Böke, Marc; Niermann, Benedikt; Winter, Jörg

    2013-11-01

    An argon/nitrogen (0.999/0.001) filamentary pulsed discharge operated at atmospheric pressure in a quartz tube is characterized using voltage-current measurements, microphotography, optical emission spectroscopy (OES) and absorption spectroscopy. Nitrogen is applied as a sensor gas for the purpose of OES diagnostic. The density of argon metastable atoms Ar(3P2) is determined using tunable diode laser absorption spectroscopy (TDLAS). Using a plasma chemical model the measured OES data are applied for the characterization of the plasma conditions. Between intense positive pulses the discharge current oscillates with a damped amplitude. It is established that an electric current flows in this discharge not only through a thin plasma filament that is observed in the discharge image but also through the whole cross section of the quartz tube. A diffuse plasma fills the quartz tube during a time between intense current pulses. Ionization waves are propagating in this plasma between the spike and the grounded area of the tube producing thin plasma channels. The diameter of these channels increases during the pause between the propagation of ionization waves probably because of thermal expansion and diffusion. Inside the channels electron densities of ˜2 × 1013 cm-3, argon metastable densities ˜1014 cm-3 and a reduced electric field about 10 Td are determined.

  11. LIQUID ARGON CALORIMETER PERFORMANCE AT HIGH RATES

    CERN Document Server

    Kukhtin, V; The ATLAS collaboration

    2011-01-01

    The performance of the ATLAS liquid argon endcap and forward calorimeters has been projected at the planned high luminosity LHC option HL-LHC by exposing small calorimeter modules of the electromagnetic, hadronic, and forward calorimeters to high intensity proton beams at IHEP/Protvino accelerator. The results of HV current and of pulse shape analysis, and also the dependence of signal amplitude on beam intensity are presented.

  12. An impact hypothesis for Venus argon anomalies

    Science.gov (United States)

    Kaula, W. M.; Newman, W. I.

    1997-03-01

    The Ar-36+38 argon-excess anomally of Venus has been hypothesized to have its origin in the impact of an outer solar system body of about 100-km diameter. A critical evaluation is made of this hypothesis and its competitors; it is judged that its status must for the time being remain one of 'Sherlock Holmes' type, in that something so improbable must be accepted when all alternatives are eliminated.

  13. Usefulness of human coagulation and fibrinolysis assays in domestic pigs

    DEFF Research Database (Denmark)

    Münster, Anna-Marie Bloch; Olsen, Aage Kristian; Bladbjerg, Else-Marie

    2002-01-01

    Pigs are often used as animal models in research on blood coagulation and fibrinolysis. The usefulness of the assays applied within this field, and the knowledge of reference intervals are therefore essential and of utmost importance. In the study reported here, we investigated the applicability...... time, tissue factor, tissue factor pathway inhibitor, factor VII, protein C, protein S, prothrombin fragment 1+2, antithrombin, thrombin-antithrombin complexes, fibrinogen, soluble fibrin, urokinase-type plasminogen activator, plasmin inhibitor, plasminogen activator inhibitor 1, and D-dimer. We found...... that 11 of 12 functional assays, but only 3 of 10 immunoassays, were applicable to porcine plasma, and we determined the normal range of these variables. We conclude that human functional assays are useful in porcine plasma, whereas only a few immunologic assays can be used. However, precautions must...

  14. Diagnostics of Atmospheric Pressure Surface Discharge Plasmas in Argon

    Institute of Scientific and Technical Information of China (English)

    张锐; 詹如娟; 温晓辉

    2003-01-01

    Atmospheric pressure surface discharge is shown to have great prospects for a number of industrial applications.To acquire better results in application fields and considering that the study of the basic parameters including electron temperature and electron density is desirable,we develop an equivalent circuit model and the diagnostic techniques based on optical emission spectroscopy and electrical measurement in our laboratory.The electron temperature has been determined to be about 0.7eV by a Fermi-Dirac model.The electron density has been calculated to be near 1010 cm-3 from a time resolved electrical measurement(Ohmic heating method).

  15. Coagulation-induced shedding of platelet glycoprotein VI mediated by factor Xa.

    Science.gov (United States)

    Al-Tamimi, Mohammad; Grigoriadis, George; Tran, Huy; Paul, Eldho; Servadei, Patricia; Berndt, Michael C; Gardiner, Elizabeth E; Andrews, Robert K

    2011-04-01

    This study evaluated shedding of the platelet collagen receptor, glycoprotein VI (GPVI) in human plasma. Collagen or other ligands induce metalloproteinase-mediated GPVI ectodomain shedding, generating approximately 55-kDa soluble GPVI (sGPVI) and approximately 10-kDa platelet-associated fragments. In the absence of GPVI ligands, coagulation of platelet-rich plasma from healthy persons induced GPVI shedding, independent of added tissue factor, but inhibitable by metalloproteinase inhibitor, GM6001. Factor Xa (FXa) common to intrinsic and tissue factor-mediated coagulation pathways was critical for sGPVI release because (1) shedding was strongly blocked by the FXa-selective inhibitor rivaroxaban but not FIIa (thrombin) inhibitors dabigatran or hirudin; (2) Russell viper venom that directly activates FX generated sGPVI, with complete inhibition by enoxaparin (inhibits FXa and FIIa) but not hirudin; (3) impaired GPVI shedding during coagulation of washed platelets resuspended in FX-depleted plasma was restored by adding purified FX; and (4) purified FXa induced GM6001-inhibitable GPVI shedding from washed platelets. In 29 patients with disseminated intravascular coagulation, mean plasma sGPVI was 53.9 ng/mL (95% confidence interval, 39.9-72.8 ng/mL) compared with 12.5 ng/mL (95% confidence interval, 9.0-17.3 ng/mL) in thrombocytopenic controls (n = 36, P coagulation-induced GPVI shedding via FXa down-regulates GPVI under procoagulant conditions. FXa inhibitors have an unexpected role in preventing GPVI down-regulation.

  16. Coagulation behavior of polyaluminum chloride:Effects of pH and coagulant dosage☆

    Institute of Scientific and Technical Information of China (English)

    Ning Wei; Zhongguo Zhang; Dan Liu; Yue Wu; Jun Wang; Qunhui Wang

    2015-01-01

    Coagulation mechanisms of polyaluminum chloride (PACl) at various dosages were studied using a conventional jar test at different final and initial pH values during treating kaolin suspension. The optimal final pH and dosages for PACl were obtained based on residual turbidity and zeta potential of flocs. The coagulation zones at various PACl dosages and solution pH values were developed and compared with those of alum. It is found that the optimal mechanism under acidic condition is charge neutralization, while alkaline condition wil facilitate the coagulation of PACl. Both charge neutralization coagulation and sweep coagulation can achieve high coagulation efficiency under the alkaline condition ranging from final pH 7.0 to 10.0. Stabilization, charge neutralization destabilization, restabilization and sweep zones occur successively with increasing PACl dosages with the final pH values fixed at 7.0 and 8.0, but restabilization zone disappears at final pH 10.0. When the final pH is not controlled and consequently decreases with increasing PACl dosage, no typical sweep zone can be observed and the coagulant efficiency decreases at high PACl dosage. It seems that the final pH is more meaningful than the initial pH for coagulation. Charge neutralization coagulation efficiency is dominated by zeta potential of flocs and PACl precipitates. The charge neutralization and sweep coagulation zones of PACl are broader in the ranges of coagulant dosage and pH than those of alum. The results are helpful for us to treat water and wastewa-ter using PACl and to understand the coagulation process of PACl.

  17. Study on the Efficacy of Abstergent Autologous Blood Transfusion Combined with Fresh Frozen Plasma in Preventing Coagulation Disorders after Operation%洗涤式自体血回输联合新鲜冰冻血浆预防术后凝血功能障碍

    Institute of Scientific and Technical Information of China (English)

    唐新桥; 陈建明; 李慧梁; 蔡丹; 周巧群; 罗旭倩

    2014-01-01

    【目的】探讨洗涤自体血回输联合使用新鲜冰冻血浆预防术后凝血障碍的疗效。【方法】选取2012年1月至2013年12月本院收治的大出血患者90例,按照患者的术中失血量大小,将其分为小量组(<400mL,n=50)、中量组(400~800mL,n=20)和大量组(>800mL,n=20)。根据回输血量多少与患者凝血功能的量化关系,制定联合新鲜冰冻血浆输注的具体方案。比较分析三组患者纤维蛋白原(FIB)、血小板(PLT)及凝血酶原时间(PT)变化情况。【结果】回输血液后三组患者机体FIB、PLT均较术前显著降低,PT明显延长(P<0.05);术后18h三组患者FIB、PLT均较回输血液后明显升高,PT显著缩短(P<0.05)。【结论】联合新鲜冰冻血浆输注的具体方案能提高洗涤自体血回输的安全性和实用性,有效预防凝血功能障碍的发生。%Objective To explore the efficacy of abstergent autologous blood transfusion combined with fresh frozen plasma in preventing coagulation disorders after operation .[Methods] Totally 90 patients with hemorrhea in our hospital from Jan .2012 to Sept .2013 were chosen .According to blood loss volume ,all pa-tients were divided into small volume group(800ml) .On the basis of the quantitative relation between blood transfusion volume and coagulation function of patients ,the concrete scheme about the combined fresh frozen plasma transfusion was made .Fi-brinogen(FIB) ,platelet(PLT) and prothrombin time(PT ) in 3 groups at different time point were analyzed and compared .[Results] Compared with before blood transfusion ,FIB and PLT in 3 groups after blood trans-fusion were decreased significantly and PT was prolonged obviously ( P <0 .05) .Compared with after blood transfusion ,FIB and PLT in 3 groups 18h after blood transfusion were increased obviously and PT was short-ened significantly( P < 0 .05) .[Conclusion]The concrete scheme about the

  18. [New oral anticoagulants - influence on coagulation tests].

    Science.gov (United States)

    Simeon, L; Nagler, M; Wuillemin, W A

    2014-01-01

    The new oral anticoagulants (NOACs) represent alternative antithrombotic agents for prophylaxis and therapy of thromboembolic diseases. They act either by inhibition of the clotting factor Xa or IIa (thrombin). As a consequence, they influence several coagulation assays (for example prothrombin time, activated partial thromboplastin time). Because of the short half-life of these new agents, these changes show great variations in the course of 24 hours. Furthermore, there are significant differences of laboratory results depending on the used reagents. We explain the influence of apixaban, rivaroxaban (factor Xa inhibitors) and dabigatran (thrombin inhibitor) on the most commonly used coagulation assays. Besides we show that this influence depends on the way of action of the drug as well as on the principle of the coagulation assay. Being aware of this relationships helps to interpret the results of coagulation assays under influence of NOACs correctly.

  19. Identification of the blood coagulation factor interacting sequences in staphylococcal superantigen-like protein 10.

    Science.gov (United States)

    Itoh, Saotomo; Takii, Takemasa; Onozaki, Kikuo; Tsuji, Tsutomu; Hida, Shigeaki

    2017-03-25

    Staphylococcal superantigen-like proteins (SSLs) are a family of exoproteins of Staphylococcus aureus. We have shown that SSL10 binds to vitamin K-dependent coagulation factors and inhibits blood coagulation induced by recalcification of citrated plasma. SSL10 was revealed to bind to coagulation factors via their γ-carboxyglutamic acid (Gla) domain. In this study we attempted to identify the responsible sequence of SSL10 for the interaction with coagulation factors. We prepared a series of domain swap mutants between SSL10 and its paralog SSL7 that does not interact with coagulation factors, and examined their binding activity to immobilized prothrombin using ELISA-like binding assay. The domain swap mutants that contained SSL10β1-β3 ((23)MEMKN ISALK HGKNN LRFKF RGIKI QVL(60)) bound to immobilized prothrombin, and mutants that contained SSL10β10-β12 ((174)SFYNL DLRSK LKFKY MGEVI ESKQI KDIEV NLK(207)) also retained the binding activity. On the other hand, mutants that lacked these two regions did not bind to prothrombin. These sequences, each alone, bound to prothrombin as 33 amino acid length polypeptides. These results suggest that SSL10 has two responsible sequences for the binding to prothrombin. These prothrombin-binding peptides would contribute to the development of new anticoagulants.

  20. Effects of nucleotides and nucleosides on coagulation

    DEFF Research Database (Denmark)

    Bune, Laurids; Thaning, Pia; Johansson, Pär I;

    2010-01-01

    Nucleotides, including ADP, ATP and uridine triphosphate (UTP), are discharged profusely in the circulation during many pathological conditions including sepsis. Sepsis can cause hypotension and systemic activation of the coagulation and fibrinolytic systems in humans, which may cause disseminated...... intravascular coagulation. We investigated whether nucleotide-induced cardiovascular collapse as provoked by systemic infusion of adenosine, ADP, ATP, UTP and nitric oxide affected the haemostatic system as assessed by whole blood thromboelastography (TEG) analysis. Ten pigs received a randomized infusion...

  1. Are the argon metastables important in high power impulse magnetron sputtering discharges?

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J. T., E-mail: tumi@hi.is [Department of Space and Plasma Physics, School of Electrical Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavik (Iceland); Lundin, D.; Minea, T. M. [Laboratoire de Physique des Gaz et Plasmas - LPGP, UMR 8578 CNRS, Université Paris-Sud, 91405 Orsay Cedex (France); Stancu, G. D. [CentraleSupélec, Grande Voie des Vignes, 92295 Chatenay-Malabry Cedex (France); CNRS, UPR 288 Laboratoire EM2C, Grande Voie des Vignes, 92295 Chatenay-Malabry Cedex (France); Brenning, N. [Department of Space and Plasma Physics, School of Electrical Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Plasma and Coatings Physics Division, IFM-Materials Physics, Linköping University, SE-581 83 Linköping (Sweden)

    2015-11-15

    We use an ionization region model to explore the ionization processes in the high power impulse magnetron sputtering (HiPIMS) discharge in argon with a titanium target. In conventional dc magnetron sputtering (dcMS), stepwise ionization can be an important route for ionization of the argon gas. However, in the HiPIMS discharge stepwise ionization is found to be negligible during the breakdown phase of the HiPIMS pulse and becomes significant (but never dominating) only later in the pulse. For the sputtered species, Penning ionization can be a significant ionization mechanism in the dcMS discharges, while in the HiPIMS discharge Penning ionization is always negligible as compared to electron impact ionization. The main reasons for these differences are a higher plasma density in the HiPIMS discharge, and a higher electron temperature. Furthermore, we explore the ionization fraction and the ionized flux fraction of the sputtered vapor and compare with recent experimental work.

  2. Influence of nitrogen admixture to argon on the ion energy distribution in reactive high power pulsed magnetron sputtering of chromium

    Science.gov (United States)

    Breilmann, W.; Maszl, C.; Hecimovic, A.; von Keudell, A.

    2017-04-01

    Reactive high power impulse magnetron sputtering (HiPIMS) of metals is of paramount importance for the deposition of various oxides, nitrides and carbides. The addition of a reactive gas such as nitrogen to an argon HiPIMS plasma with a metal target allows the formation of the corresponding metal nitride on the substrate. The addition of a reactive gas introduces new dynamics into the plasma process, such as hysteresis, target poisoning and the rarefaction of two different plasma gases. We investigate the dynamics for the deposition of chromium nitride by a reactive HiPIMS plasma using energy- and time-resolved ion mass spectrometry, fast camera measurements and temporal and spatially resolved optical emission spectroscopy. It is shown that the addition of nitrogen to the argon plasma gas significantly changes the appearance of the localized ionization zones, the so-called spokes, in HiPIMS plasmas. In addition, a very strong modulation of the metal ion flux within each HiPIMS pulse is observed, with the metal ion flux being strongly suppressed and the nitrogen molecular ion flux being strongly enhanced in the high current phase of the pulse. This behavior is explained by a stronger return effect of the sputtered metal ions in the dense plasma above the racetrack. This is best observed in a pure nitrogen plasma, because the ionization zones are mostly confined, implying a very high local plasma density and consequently also an efficient scattering process.

  3. 内镜下氩离子凝固术治疗结直肠息肉92例护理体会%Experience of nursing care in the treatment of 92 patients with colorectal polyp by using argon ion plasma coagulation under endoscope

    Institute of Scientific and Technical Information of China (English)

    郭荣; 王明英; 吕燕; 曹允芳

    2007-01-01

    目的:探讨内镜下氩离子凝固术(APC)治疗结、直肠息肉的护理方法.方法:对92例结、直肠息肉患者采用内镜下APC联合高频电切术进行治疗.结果:本组56例息肉直径<4mm者,采用APC 1次性治疗消除;36例息肉直径>4mm者,根据不同形态及有无蒂采用粘膜下注射生理盐水、高频电切除术,对残端有渗血或息肉残留者再用APC处理,效果满意,且无不良反应.结论:APC治疗结、直息肉患者痛苦小,值得推广应用.

  4. EDITORIAL: Focus on Plasma Medicine

    Science.gov (United States)

    Morfill, G. E.; Kong, M. G.; Zimmermann, J. L.

    2009-11-01

    -pressure microwave plasmas in an N2 and O2 gas mixture M K Singh, A Ogino and M Nagatsu Degradation of adhesion molecules of G361 melanoma cells by a non-thermal atmospheric pressure microplasma H J Lee, C H Shon, Y S Kim, S Kim, G C Kim and M G Kong The acidification of lipid film surfaces by non-thermal DBD at atmospheric pressure in air A Helmke, D Hoffmeister, N Mertens, S Emmert, J Schuette and W Vioel Reduction and degradation of amyloid aggregates by a pulsed radio-frequency cold atmospheric plasma jet D L Bayliss, J L Walsh, G Shama, F Iza and M G Kong The effect of low-temperature plasma on bacteria as observed by repeated AFM imaging René Pompl, Ferdinand Jamitzky, Tetsuji Shimizu, Bernd Steffes, Wolfram Bunk, Hans-Ulrich Schmidt, Matthias Georgi, Katrin Ramrath, Wilhelm Stolz, Robert W Stark, Takuya Urayama, Shuitsu Fujii and Gregor Eugen Morfill Removal and sterilization of biofilms and planktonic bacteria by microwave-induced argon plasma at atmospheric pressure Mi Hee Lee, Bong Joo Park, Soo Chang Jin, Dohyun Kim, Inho Han, Jungsung Kim, Soon O Hyun, Kie-Hyung Chung and Jong-Chul Park Cell permeabilization using a non-thermal plasma M Leduc, D Guay, R L Leask and S Coulombe Physical and biological mechanisms of direct plasma interaction with living tissue Danil Dobrynin, Gregory Fridman, Gary Friedman and Alexander Fridman Nosocomial infections-a new approach towards preventive medicine using plasmas G E Morfill, T Shimizu, B Steffes and H-U Schmidt Generation and transport mechanisms of chemical species by a post-discharge flow for inactivation of bacteria Takehiko Sato, Shiroh Ochiai and Takuya Urayama Low pressure plasma discharges for the sterilization and decontamination of surfaces F Rossi, O Kylián, H Rauscher, M Hasiwa and D Gilliland Contribution of a portable air plasma torch to rapid blood coagulation as a method of preventing bleeding S P Kuo, O Tarasenko, J Chang, S Popovic, C Y Chen, H W Fan, A Scott, M Lahiani, P Alusta, J D Drake and M Nikolic A two

  5. Blood coagulation screening using a paper-based microfluidic lateral flow device.

    Science.gov (United States)

    Li, H; Han, D; Pauletti, G M; Steckl, A J

    2014-10-21

    A simple approach to the evaluation of blood coagulation using a microfluidic paper-based lateral flow assay (LFA) device for point-of-care (POC) and self-monitoring screening is reported. The device utilizes whole blood, without the need for prior separation of plasma from red blood cells (RBC). Experiments were performed using animal (rabbit) blood treated with trisodium citrate to prevent coagulation. CaCl2 solutions of varying concentrations are added to citrated blood, producing Ca(2+) ions to re-establish the coagulation cascade and mimic different blood coagulation abilities in vitro. Blood samples are dispensed into a paper-based LFA device consisting of sample pad, analytical membrane and wicking pad. The porous nature of the cellulose membrane separates the aqueous plasma component from the large blood cells. Since the viscosity of blood changes with its coagulation ability, the distance RBCs travel in the membrane in a given time can be related to the blood clotting time. The distance of the RBC front is found to decrease linearly with increasing CaCl2 concentration, with a travel rate decreasing from 3.25 mm min(-1) for no added CaCl2 to 2.2 mm min(-1) for 500 mM solution. Compared to conventional plasma clotting analyzers, the LFA device is much simpler and it provides a significantly larger linear range of measurement. Using the red colour of RBCs as a visible marker, this approach can be utilized to produce a simple and clear indicator of whether the blood condition is within the appropriate range for the patient's condition.

  6. Effect of Crocus sativus L. (saffron) on coagulation and anticoagulation systems in healthy volunteers.

    Science.gov (United States)

    Ayatollahi, Hossein; Javan, Atefeh Ordoei; Khajedaluee, Mohammad; Shahroodian, Masood; Hosseinzadeh, Hossein

    2014-04-01

    Saffron showed some effects on blood coagulation and platelet aggregation in in vitro and in vivo studies. In a clinical trial with a limited number volunteers, saffron tablets influenced on bleeding time. In this study, the effect of saffron on plasma level of fibrinogen, factor VII (as coagulant agent), C and S protein (as anti-coagulant agent), PT and PTT in a larger sample size was evaluated. The study was a double-blind, placebo-controlled study consisting of 1 week treatment with 200 mg and 400 mg saffron tablets. Sixty healthy volunteers (age range 20-50 years) were selected for the study. The volunteers were divided into three groups of 20 each. Group 1 received placebo; Groups 2 and 3 received 200 mg and 400 mg saffron tablets, respectively, for 7 days (1 tablet per day). Before and after 7 days treatment and also 1 month after that, blood samples were taken. The plasma levels of fibrinogen, factor VII, C and S protein, PT and PTT were evaluated. Statistical analysis showed no difference between groups for any of evaluated factors. This study rejected any effect of saffron with dose of 200 and 400 mg for 1 week on coagulant and anticoagulant system.

  7. Argon diffusion from biotite at high temperature and pressure

    Institute of Scientific and Technical Information of China (English)

    陈道公; 贾命命; 李彬贤; 陆全明; 谢鸿森; 侯渭

    1995-01-01

    t The experiments of argon diffusion dynamics for biotite were carried out at 700 -1000℃ and 0.5 - 2,0 GPa and the diffusion coefficient and activation energy using different models have been calculated. The results indicate that the pressure does affect the argon diffusion and its effect is opposite to that of temperature. When p increases, the activation energy increases and diffusion coefficient decreases. The relation between pressure, closure temperature and cooling rate has been obtained. It is postulated that in low T and high p conditions, the argon diffusion from the environment to the system could occur and incur the appearance of the external argon in minerals.

  8. Numerical and experimental study of transferred arcs in argon

    Energy Technology Data Exchange (ETDEWEB)

    Bini, R [Department of Mechanical Engineering, Politecnico di Milano, Via Bonardi 9, 20133 Milan (Italy); Monno, M [Department of Mechanical Engineering, Politecnico di Milano, Via Bonardi 9, 20133 Milan (Italy); Boulos, M I [Centre de Recherche en Energie, Plasma et Electrochimie (CREPE), Department de Genie Chimique Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, J1K1R2 (Canada)

    2006-08-07

    The bidimensional model of the electric arc is enhanced with the plasma-electrodes interaction to predict the properties and the energy distribution of an argon arc operating with current intensities between 100 and 200 A and electrode gaps of 10 and 20 mm. An adaptive numerical insulation is applied to the cathode, to properly simulate its thermionic emission mechanism and overcome the dependence on empirical distributions of the current density at its tip. The numerical results are quantitatively compared with the data obtained from calorimetric and spectroscopical measurements, performed on a device which generates a transferred arc between a water cooled copper anode and a thoriated tungsten cathode enclosed in a stainless steel chamber. The calculation of the heat fluxes towards the electrodes permits to determine the amount of power delivered to each component of the arc system (the anode, the cathode assembly and the chamber) and to evaluate the overall efficiency of the process for different configurations. The agreement between theory and data, over the range of parameters investigated, is sensible both in the temperature profiles and in the energy distributions. In such configurations, the conduction from the hot gas is the most relevant term in the overall heat transferred to the anode, but it is the electron transfer which rules the heat transfer in the arc attachment zone. The arc attachment radius is also dependent on the process parameters and increases with the arc current (from approximately 5 mm at 100 A to 7 mm at 200 A) and the arc length. However the maximum heat flux reached on the axis decreases increasing the gap between the electrodes, although more power is delivered to the anode due to the radial spreading of the plasma. A 10 mm 200 A argon arc releases to the anode about 2.6 kW, which corresponds to 75% of the total arc power available. If the arc is extended to 20 mm the power transferred rises by nearly 350 W, but the overall

  9. Argon isotope fractionation induced by stepwise heating

    Science.gov (United States)

    Trieloff, Mario; Falter, Martina; Buikin, Alexei I.; Korochantseva, Ekaterina V.; Jessberger, Elmar K.; Altherr, Rainer

    2005-03-01

    Noble gas isotopes are widely used to elucidate the history of the rocks in which they have been trapped, either from distinct reservoirs or by accumulation following radioactive decay. To extract noble gases from their host rocks, stepwise heating is the most commonly used technique to deconvolve isotopically different components, e.g., atmospheric, in situ radiogenic, or excess radiogenic from mantle or crustal reservoirs. The accurate determination of the isotopic composition of these different components is of crucial importance, e.g., for ages obtained by 40Ar- 39Ar stepheating plateaus. However, diffusion theory-based model calculations predict that the stepwise thermal extraction process from mineral phases induces isotope fractionation and, hence, adulterates the original composition. Such effects are largely unconsidered, as they are small and a compelling experimental observation is lacking. We report the first unequivocal evidence for significant mass fractionation of argon isotopes during thermal extraction, observed on shungite, a carbon-rich Precambrian sedimentary rock. The degree of fractionation, as monitored by 38Ar/ 36Ar and 40Ar/ 36Ar ratios, very well agrees with theoretical predictions assuming an inverse square root dependence of diffusion coefficient and atomic mass, resulting in easier extraction of lighter isotopes. Hence, subatmospheric 40Ar/ 36Ar ratios obtained for argon extracted at low temperatures may not represent paleoatmospheric argon. Shungite argon resembles modern atmospheric composition, but constraints on the timing of trapping appear difficult to obtain, as shungites are multicomponent systems. In 40Ar- 39Ar stepwise heating, the isotope fractionation effect could cause systematic underestimations of plateau ages, between 0.15 and 0.4% depending on age, or considerably higher if samples contain appreciable atmospheric Ar. The magnitude of this effect is similar to the presently achieved uncertainties of this increasingly

  10. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  11. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  12. 产后出血患者大量输血治疗时血浆和红细胞的比例对凝血功能的影响%Effect of ratio of fresh frozen plasma to red blood cells on coagulation function in patients with massive blood transfusion for postpartum hemorrhage

    Institute of Scientific and Technical Information of China (English)

    刘桂芳; 金勇; 夏和凤

    2016-01-01

    目的 探讨产后大出血患者早期大量输血时,输入新鲜冰冻血浆(FFP)和红细胞(RBC)的比例对凝血功能的影响.方法 因产后大出血24 h内需输注RBC大于10 U的患者45例,按输注FFP与悬浮RBC的比例,随机分为低血浆组(A组,FFP∶ RC=1∶2.5,15例)、中血浆组(B组,FFP∶ RBC=1∶1,16例)和高血浆组(C组,FFP∶ RBC=1.5∶1,14例).检测产前和输血后24h凝血功能和血常规,比较三组患者大量输血后24h内RBC和冷沉淀输入量的差异.结果 三组患者产前凝血功能、血常规比较无统计学差异(P>0.05).大量输血24 h后,A组凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)延长,纤维蛋白原(Fbg)含量降低(P<0.05),B、C组凝血功能无明显变化(P>0.05);三组患者大量输血后血小板计数(Plt)及血红蛋白(Hb)均降低(P<0.05),B组优于A、C组(P<0.05).三组间24 h内输注RBC和冷沉淀的量无统计学差异(P>0.05).结论 产后大出血患者输血时,FFP与RBC比例过低,可造成血液稀释性低凝,建议以1∶1比例输注为宜.%Objective To investigate the effect of ratio of fresh frozen plasma(FFP) to red blood cells (RBC) on coagulation function in the patients with massive blood transfusion for postpartum hemorrhage.Methods Forty-five patients with blood transfusion more than 10 U in 24 hours were randomly assigned into three groups of A(ratio of FFP to RBC 1 ∶ 2.5,15 cases),B(ratio of FFP to RBC 1 ∶ 1,16 cases) and C(ratio of FFP to RBC 1.5 ∶ 1,14 cases).The coagulation function was examined before delivery and at 24 hours after transfusion.The volumes of RBC and cryoprecipitate infused in 24 hours were compared among three groups.Results The tests of coagulation function,platelet and hemoglobin (Hb) of three groups were similar before delivery (P>0.05).The prothrombin time (PT) and activated partial thromboplastin time (APTT) were significantly prolonged and fibrinogen was decreased at 24 hours after

  13. Study on statistical breakdown delay time in argon gas using a W-band millimeter-wave gyrotron

    Science.gov (United States)

    Kim, Dongsung; Kim, Sung Gug; Sawant, Ashwini; Yu, Dongho; Choe, MunSeok; Choi, EunMi

    2016-04-01

    In this study, we investigated plasma initiation delay times for argon volume breakdown at the W-band frequency regime. The threshold electric field is defined as the minimum electric field amplitude needed for plasma breakdown at various pressures. The measured statistical delay time showed an excellent agreement with the theoretical Gaussian distribution and the theoretically estimated formative delay time. Also, we demonstrated that the normalized effective electric field as a function of the product of pressure and formative time shows an outstanding agreement to that of 1D particle-in-cell simulation coupled with a Monte Carlo collision model [H. C. Kim and J. P. Verboncoeur, Phys. Plasmas 13, 123506 (2006)].

  14. Postoperative bleeding in a patient with normal screening coagulation tests.

    Science.gov (United States)

    Nourbakhsh, Eva; Anvari, Reza; D'cunha, Nicholas; Thaxton, Lauren; Malik, Asim; Nugent, Kenneth

    2011-09-01

    A 54-year-old man was brought to the emergency room after a head-on collision. He had multiple fractures in his lower extremities and required immediate surgery. After surgery, the patient had a persistent drop in hemoglobin, hematocrit and platelets despite red blood cell transfusions. Laboratory studies included normal prothrombin time, activated partial thromboplastin time, normal plasminogen functional activity, negative antiplatelet antibodies, normal platelet functional analysis and negative disseminated intravascular coagulation screen. Factor XIII antigen levels were 25% of predicted, and the diagnosis of factor XIII deficiency was made. The patient was treated with cryoprecipitate, and the bleeding stopped. Patients with factor XIII deficiency have either a rare congenital or acquired coagulation disorder. Both presentations have normal standard laboratory clotting tests, and the diagnosis requires an assay measuring factor XIII activity or antigen levels. The usual treatment includes cryoprecipitate, fresh-frozen plasma or recombinant factor XIII. This deficiency should be considered in patients with unexplained spontaneous, traumatic or postoperative bleeding.

  15. Characterization of atmospheric pressure microplasma produced from argon and a mixture of argon–ethylenediamine

    Energy Technology Data Exchange (ETDEWEB)

    Bashir, M., E-mail: ranabashir77@gmail.com [Department of Chemical and Biological Engineering and Kroto Research Institute, University of Sheffield, Sheffield S1 3JD (United Kingdom); Rees, Julia M.; Bashir, S. [School of Mathematics and Statistics, Hicks Building, Hounsfield Road, University of Sheffield, Sheffield S3 7RH (United Kingdom); Zimmerman, William B. [Department of Chemical and Biological Engineering and Kroto Research Institute, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2014-06-27

    A non-thermal atmospheric pressure microplasma generated from pure argon (Ar) and a mixture of argon–ethylenediamine vapors (Ar/EDA) has been characterized in this study. A sinusoidal power supply operating at 30 kHz was used to excite microplasma in a rectangular borosilicate glass capillary (4×0.4 mm{sup 2}). The monomer EDA was mixed with Ar in order to perform plasma polymerization inside the microchannel. The analyses were made by measuring spectroscopic and electrical parameters of the discharge. The effects of EDA mixing on plasma parameters such as electron, excitation and rotational temperatures during the process of surface coating of the microchannel were investigated. These parameters play an important role in the deposition process. The plasma temperatures estimated through spectroscopic measurement were found in the sequence T{sub e}>T{sub exc}>T{sub vib}>T{sub rot}, which indicated the non-thermal characteristics of the proposed DBD microplasma. The parameters of the Ar discharge were also numerically computed using plasma simulations. The numerical predictions of electron temperature (2D simulations) and electron density (3D simulations) were found to be in close agreement to those estimated through experiments. - Highlights: • An atmospheric pressure microplasma was generated in a borosilicate glass capillary. • A pure argon and a mixture of argon–ethylenediamine plasmas were characterized. • Characterization was performed by emission spectrometry and electrical measurements. • Plasma parameters were also predicted by numerical simulations. • The sequence of estimated plasma temperatures indicated its non-thermal behaviour.

  16. Magnetic particle imaging of blood coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu [Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Graduate School of Medicine, Osaka University, Osaka 565-0871 (Japan)

    2014-06-23

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

  17. Diagnosis and treatment of disseminated intravascular coagulation.

    Science.gov (United States)

    Levi, M

    2014-06-01

    Disseminated intravascular coagulation (DIC) is a condition in which systemic activation of coagulation without a specific localization occurs, resulting in extensive formation of intravascular fibrin, particularly in small and midsize vessels. Disseminated intravascular coagulation may lead to several altered coagulation parameters, including a low platelet count, abnormal global clotting assays, low levels of physiological anticoagulant proteases, or increased fibrin degradation products. Also, more complex assays for activation of coagulation factors or pathways may indicate involvement of these molecules in DIC. None of these tests alone, however, can accurately ascertain or rebuff a diagnosis of DIC. Nonetheless, a combination of readily available routine assays may be instrumental in establishing a diagnosis of DIC and can also be useful to point to a subset of patients with DIC that may need definite, often costly, interventions in the hemostatic system. Current insights on relevant etiological pathways that may contribute to the occurrence of DIC have led to innovative therapeutic and adjunctive approaches to patient with DIC. Management options directed at the amelioration of hemostatic activation may tentatively be indicated and were found to be advantageous in experimental and clinical investigations. These treatments encompass elimination of tissue factor-mediated thrombin generation or restitution of normal anticoagulant function.

  18. Magnetic particle imaging of blood coagulation

    Science.gov (United States)

    Murase, Kenya; Song, Ruixiao; Hiratsuka, Samu

    2014-06-01

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl2 to whole sheep blood mixed with magnetic nanoparticles (MNPs). The "MPI value" was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

  19. Alterations in Blood Coagulation and Viscosity Among Young Male Cigarette Smokers of Al-Jouf Region in Saudi Arabia.

    Science.gov (United States)

    Almarshad, Hassan A; Hassan, Fathelrahman M

    2016-05-01

    Hemorheology, a measure of rheological properties of blood, is often correlated with cerebral blood flow and cardiac output; an increased blood viscosity may increase the risk of thrombosis or thromboembolic events. Previous studies have reported a large variation in hemorheological properties of blood among smokers. This prompted us to conduct coagulation experiments to evaluate the effect of cigarette smoking on hematological parameters, like cell counts, and coagulation parameters among young males in Al-Jouf region, Saudi Arabia. The hematological and coagulation parameters were used to relate the changes in viscosity and coagulation to smoking. A total of 321 male participants (126 nonsmokers and 195 smokers) were enrolled into the study as randomized sample. Complete blood count was measured by hematology analyzer, and coagulation tests were performed by coagulation analyzer. Thettest analysis was performed to compare the relationships of variables between the 2 groups. The results confirmed that smoking alters some hematology parameters leading to significant deterioration in blood flow properties. Smoking also increased the hematocrit (HCT), whole blood viscosity (WBV), and plasma viscosity (PV) but decreased the international normalized ratio (INR). The decrease in INR was found to be associated with the increase in WBV, PV, and HCT. Further investigations are necessary to assess the reversibility of such changes in cessation of smoking or other elements of influence.

  20. Plasma metallization

    CERN Document Server

    Crowther, J M

    1997-01-01

    Many methods are currently used for the production of thin metal films. However, all of these have drawbacks associated with them, for example the need for UHV conditions, high temperatures, exotic metal precursors, or the inability to coat complex shaped objects. Reduction of supported metal salts by non-isothermal plasma treatment does not suffer from these drawbacks. In order to produce and analyse metal films before they become contaminated, a plasma chamber which could be attached directly to a UHV chamber with XPS capability was designed and built. This allowed plasma treatment of supported metal salts and surface analysis by XPS to be performed without exposure of the metal film to the atmosphere. Non-equilibrium plasma treatment of Nylon 66 supported gold(lll) chloride using hydrogen as the feed gas resulted in a 95% pure gold film, the remaining 5% of the film being carbon. If argon or helium were used as the feed gases during plasma treatment the resultant gold films were 100% pure. Some degree of s...

  1. Impact of Albumin on Coagulation Competence and Hemorrhage During Major Surgery: A Randomized Controlled Trial.

    Science.gov (United States)

    Rasmussen, Kirsten C; Højskov, Michael; Johansson, Pär I; Kridina, Irina; Kistorp, Thomas; Salling, Lisbeth; Nielsen, Henning B; Ruhnau, Birgitte; Pedersen, Tom; Secher, Niels H

    2016-03-01

    For patients exposed to a massive blood loss during surgery, maintained coagulation competence is important. It is less obvious whether coagulation competence influences bleeding during elective surgery where patients are exposed to infusion of a crystalloid or a colloid. This randomized controlled trial evaluates whether administration of 5% human albumin (HA) or lactated Ringer solution (LR) affects coagulation competence and in turn blood loss during cystectomy due to bladder cancer. Forty patients undergoing radical cystectomy were included to receive either 5% HA (n = 20) or LR (n = 20). Nineteen patients were analyzed in the HA group and 20 patients in the lactated Ringer group. Blinded determination of the blood loss was similar in the 2 groups of patients: 1658 (800-3300) mL with the use of HA and 1472 (700-4330) mL in the lactated Ringer group (P = 0.45). Yet, by thrombelastography (TEG) evaluated coagulation competence, albumin affected clot growth (TEG-angle 69 ± 5 vs 74° ± 3°, P blood loss (P = 0.042) while administration of albumin was related to the changes in TEG-MA (P = 0.029), aPPT (P blood loss as compared to infusion of LR. Also the use of HA did not affect the need for blood transfusion, the incidence of postoperative complications, or the hospital in-stay. Yet, albumin decreases coagulation competence during major surgery and the blood loss is related to TEG-MA rather than to plasma coagulation variables.

  2. Performance of a liquid argon accordion hadronic calorimeter prototype

    Energy Technology Data Exchange (ETDEWEB)

    Gingrich, D.M. [Alberta Univ., Edmonton, AB (Canada); Greeniaus, G. [Alberta Univ., Edmonton, AB (Canada); Kitching, P. [Alberta Univ., Edmonton, AB (Canada); Olsen, B. [Alberta Univ., Edmonton, AB (Canada); Pinfold, J.L. [Alberta Univ., Edmonton, AB (Canada); Rodning, N.L. [Alberta Univ., Edmonton, AB (Canada); Boos, E. [Alma-Ata (Kazakhstan); Schaoutnikov, B.O. [Alma-Ata (Kazakhstan); Aubert, B. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Bazan, A. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Beaugiraud, B. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Boniface, J. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Colas, J. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Jezequel, S. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Leflour, T. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Maire, M. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Rival, F. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Stipcevic, M. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Thion, J. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; VanDenPlas, D. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Wingerter-Seez, I. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Zolnierowski, Y.P. [Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules; Chmeissani, M. [Universidad Autonoma de Barcelona (Spain); Fernandez, E. [Universidad Autonoma de Barcelona (Spain); Garrido, L. [Universidad Autonoma de Barcelona (Spain); Martinez, M. [Universidad Autonoma de Barcelona (Spain); Padilla, C. [Universidad Autonoma de Barcelona (Spain); Gordon, H.A. [Brookhaven National Lab., Upton, NY (United States); RD3 Colla...

    1995-02-15

    A liquid argon hadronic calorimeter using the ``accordion`` geometry and the electrostatic transformer readout scheme has been tested at CERN, together with a liquid argon accordion electromagnetic prototype. The results obtained for pions on the linearity, the energy resolution and the uniformity of the calorimeter response are well within the requirements for operation at the LHC. ((orig.))

  3. Comparison of Diode and Argon Laser Lesions in Rabbit Retina

    Institute of Scientific and Technical Information of China (English)

    Hui Zhang; Xiaoxin Li; Bin Li; Jiping Da

    2004-01-01

    Purpose: To compare the histological alteration of retina with various spot intensities between diode and argon lasers in order to instruct the clinical use of 810 nm diode laser.Methods: Transpupillary retinal photocoagulations were performed on 42 eyes of 27pigmented rabbits. Histopathologic alteration of lesions in different intensities and different time intervals after irradiation produced by diode and argon laser was observed and compared using light microscopy. Areas of various lesions measured by image analysis system (CMIAS) were compared quantitatively.Results: Histopathologically, two-week-old grade 2 lesions produced by diode laser induced the disappearance of outer nuclear cells. More than a half of all showed reduction in number of outer nuclear layer cells in argon. Fibroblasts appeared in the diode grade 3lesions 5 days after irradiation. CMIAS data showed that all the areas of diode lesions immediately after photocoagulation were to be larger than those of argon laser lesions in the same spot intensity (P < 0.05). However, twenty-four hours after photocoagulation, the area of the diode lesions increased less than that of the argon laser lesions (8%vs.23%).Conclusion: The acute histological effect caused by 810 nm diode laser and argon green laser is similar,while the expansion of lesion area 24 hours after photocoagulation was less with the diode laser compared to the argon. This may be the first report in the literature regarding quantitative analysis of the delayed reaction of argon green lasers.

  4. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...

  5. Coagulation function in patients with pancreatic carcinoma

    Institute of Scientific and Technical Information of China (English)

    WANG Hang-yan; XIU Dian-rong; LI Zhi-fei; WANG Gang

    2009-01-01

    Background The coagulation function in patients with pancreatic carcinoma is abnormal and the reason is not very clear. In this study, we retrospectively analyzed the coagulation function in patients with pancreatic carcinoma.Methods From June 2004 to December 2007, 132 patients received diagnosis and treatment in our hospital. The coagulative parameters including the prothrombin time, activated partial thromboplastin time, and fibrinogen levels were collected and studied retrospectively.Results The average fibrinogen levels in patients with pancreatic carcinoma, (476.21±142.05) mg/dl, were significantly higher than in patients with cholangiolithiasis, (403.28±126.41) mg/dl (P 0.05).Conclusions The level of fibrinogen in patients with pancreatic carcinoma was elevated. The elevated fibrinogen level may be associated with invasiveness and lymphatic metastasis. Using vitamin K in perioperation management did not reduce intraoperative blood loss.

  6. Monitoring Thermal Coagulation with Ultrasonic Textures

    Institute of Scientific and Technical Information of China (English)

    YANG Wei; ZHANG Su; CHEN Ya-zhu; CHEN Lei; HU Bing; MA Wei-yin

    2007-01-01

    The feasibility of using B-mode ultrasound image textures and pattern recognition technique to characterize the thermal coagulation in vitro during radiofrequency ablation was investigated.The changes of ultrasonic textures in the different regions of samples varied with the heating time in the in-vitro experiments, which would result in that the coagulated and noncoagulated regions of tissue had different ultrasonic textures.Using support vector machine to extract the ultrasonic texture features and characterize the state of tissue, the size and boundaries of thermal lesions could be detected and measured more exactly than only using the gray scale information of B-mode ultrasound image.The proposed method would be applied to the image-guided radiofrequency ablation (IGRA) procedure for monitoring the thermal coagulation.

  7. A Power Interruption Technique for Investigation of Temperature Difference in Stabilized Low Direct-Current Arc Burning in Pure Argon on Atmospheric Pressure

    Institute of Scientific and Technical Information of China (English)

    M. M. Kuzmanovi(c); J. J. Savovi(c); D. P. Rankovi(c); M. Stoiljkovi(c); A. Anti(c)-Jovanovi(c); M.S. Pavlovi(c); M. Marinkovi(c)

    2008-01-01

    @@ Plasma of argon stabilized arc column, in a current range 3-11 A, is investigated using emission spectrometric diagnostic techniques. Temperatures are evaluated using several methods: argon line to adjacent recombinational continuum intensity ratio, absolute emissivity of argon fine, measurement of electron number density, and power interruption. Electron number density is evaluated from absolute emissivity of recombinational continuum. The difference between electron Te and heavy particle Th temperature ranged from 4500 K for 3 A to 2300 K for 11 A arc current. By comparing the present with the previously obtained results, using the same arc device but with the introduction of water aerosol, it is concluded that water aerosol reduces the difference Te - Th and brings plasma closer to the partial thermodynamic equilibrium state.

  8. Improved installation prototype for measurement of low argon-37 activity

    Science.gov (United States)

    Pakhomov, Sergei; Dubasov, Yuri

    2015-04-01

    On-site Inspection (OSI) is a key element of verification of State Parties' compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An on-site inspection is launched to establish whether or not a nuclear explosion has been carried out. One of the most significant evidence of n underground nuclear explosion (UNE) is detection above background concentrations of argon-37 in near surface air. Argon-37 is formed in large amounts at interaction of neutrons of UNE with the potassium which is a part of the majority of rocks. Its estimated contents for the 100th days after explosion with a energy of 1000 t of TNT near a surface can vary from 1 to 1000 mBq/m3. The background concentrations of argon-37 in subsoil air vary 1 do100 mBq/m3. Traditionally, for argon-37 activity measurement the gas-proportional counters are used. But at Khlopin Radium institute the developments of the new type of highly sensitive and low-background installation capable to provide the required range of measurements of the argon-37 concentration are conducted. The liquid scintillation method of the registration of the low-energetic argon-37 electrons is the basic installation principle and as scintillator, the itself condensed air argon sample is used. Registration of scintillations of liquid argon is made by means of system from 3 PMT which cathodes are cooled near to the temperature of liquid nitrogen together with the measuring chamber in which placed the quartz glass ampule, containing the measured sample of the liquefied argon. For converse the short wavelength photons (λ = 127 nm) of liquid argon scintillations to more long-wave, corresponding to the range of PMT sensitivity, the polymer film with tetra-phenyl-butadiene (TPB) is provided. Even the insignificant impurities of nitrogen, oxygen and others gaseous in the liquid argon samples can to cause the quenching of scintillation, especially their slow components. To account this effect and it influence on change of registration

  9. The investigation of coagulation activity of natural coagulants extracted from different strains of common bean

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2010-01-01

    Full Text Available Coagulation and flocculation by adding chemicals are the methods that are usually used for removal of water turbidity. This study is concerned with the coagulation activity of extracts of various strains of bean. The aim was to ascertain if bean varieties influence coagulation activity. Active components were extracted from 1 g of ground sample with 100 ml distilled water. Contents of dry matter and nitrogen were specified in the solid samples, and the content of soluble nitrogen was determined in the extracts. These data were used to calculate the efficiency of extraction of nitrogen-containing compounds. The coagulation activity was assessed by jar test using synthetic turbid water, of the initial pH 9 and turbidity 35 NTU. The jar test was carried out by adding different amounts of extracts to model water, and stirring the content. After sedimentation for 1 h, residual turbidity was determined by turbidimeter and coagulation activity was calculated. The increment of organic matter concentration after the coagulation was also determined. These experiments confirmed that extracts of all investigated strains of bean could be used successfully as natural coagulants.

  10. Coagulation factor deficiency apparently related to the Fitzgerald trait: the first cases in Japan.

    Directory of Open Access Journals (Sweden)

    Hayashi,Hisamoto

    1978-04-01

    Full Text Available A blood coagulation deficiency was found at the contact phase in identical Japanese female twins. Of the four possible factors involved, Factor XI or XII can be ruled out according to cross-correction studies. The problem factor was probably not Fletcher factor, because the abnormal partial thromboplastin time was not significantly shortened by increasing the incubation period of plasma with kaolin. The deficiency is most likely due to the lack of Fitzgerald factor.

  11. Coagulant and anticoagulant activities in Jatropha curcas latex.

    Science.gov (United States)

    Osoniyi, Omolaja; Onajobi, Funmi

    2003-11-01

    Jatropha curcas Linn. (Euphorbiaceae), a medicinal plant commonly grown in the Tropics, is traditionally used as a haemostatic. Investigation of the coagulant activity of the latex of Jatropha curcas showed that whole latex significantly (Platex, however, prolonged the clotting time: at high dilutions, the blood did not clot at all. This indicates that Jatropha curcas latex possesses both procoagulant and anticoagulant activities. Prothrombin time (PT) and activated partial thromboplastin time (APTT) tests on plasma confirm these observations. Solvent partitioning of the latex with ethyl acetate and butanol led to a partial separation of the two opposing activities: at low concentrations, the ethyl acetate fraction exhibited a procoagulant activity, while the butanol fraction had the highest anticoagulant activity. The residual aqueous fraction had no significant effect on the clotting time of blood and the PT but slightly prolonged the APTT.

  12. Impact of Argon gas on optical and electrical properties of Carbon thin films

    Science.gov (United States)

    Usman, Arslan; Rafique, M. S.; Shaukat, S. F.; Siraj, Khurram; Ashfaq, Afshan; Anjum, Safia; Imran, Muhammad; Sattar, Abdul

    2016-12-01

    Nanostructured thin films of carbon were synthesized and investigated for their electrical, optical, structural and surface properties. Pulsed Laser Deposition (PLD) technique was used for the preparation of these films under Argon gas environment. A KrF Laser (λ=248 nm) was used as source of ablation and plasma formation. It was observed that the carbon ions and the background gas environment has deep impact on the morphology as well as on the microstructure of the films. Time of Flight (TOF) method was used to determine the energies of the ablated carbon ions. The morphology of film surfaces deposited at various argon pressure was analysed using an atomic force microscope. The Raman spectroscopic measurement reveal that there is shift in phase from sp3 to sp2 and a decrease in FWHM of G band, which is a clear indication of enhanced graphitic clusters. The electrical resistivity was also reduced from 85.3×10-1 to 2.57×10-1 Ω-cm. There is an exponential decrease in band gap Eg of the deposited films from 1.99 to 1.37 eV as a function of argon gas pressure.

  13. Disseminated intravascular coagulation in burn injury.

    Science.gov (United States)

    Lippi, Giuseppe; Ippolito, Luigi; Cervellin, Gianfranco

    2010-06-01

    Disseminated intravascular coagulation (DIC) is a complex and multifaceted disorder characterized by the activation of coagulation and fibrinolytic pathways, consumption of coagulation factors, and depletion of coagulation regulatory proteins. The introduction into the circulation of cellular debris characterized by strong thromboplastic activity due to tissue factor exposition or release (in or from burned tissues), which can thereby activate extrinsic pathway of coagulation system and trigger massive thrombin generation when present in sufficient concentration, represents the most plausible biological explanation to support the development of intravascular coagulation in patients with burn injury. Severe burns left untreated might also lead to an immunological and inflammatory response (activation of the complement cascade), which can amplify fibrinolysis and blood clotting. Overall, the real prevalence of DIC in patients with burns is as yet unclear. Postmortem, retrospective, and even longitudinal investigations are in fact biased by several factors, such as the objective difficulty to establish whether DIC might have occurred as a primary complication of burns or rather as a consequence of other superimposed pathologies (e.g., sepsis, multiple organ failure), the different diagnostic criteria for assessing DIC, and the heterogeneity of the patient samples studied. Nevertheless, the current scientific evidence is consistent with the hypothesis that biochemical changes suggestive for DIC (hypercoagulability, hypo- and hyperfibrinolysis) are commonplace in patients with burn trauma, and their severity increases exponentially with the severity of injury. Overt DIC seems to occur especially in critically ill burn patients or in those with severe burns (up to third degree) and large involvement of body surface area, in whom an appropriate therapy might be effective to prevent the otherwise fulminant course. Although early prophylaxis with antithrombin concentrates

  14. Effects of nucleotides and nucleosides on coagulation

    DEFF Research Database (Denmark)

    Bune, Laurids; Thaning, Pia; Johansson, Pär I;

    2010-01-01

    intravascular coagulation. We investigated whether nucleotide-induced cardiovascular collapse as provoked by systemic infusion of adenosine, ADP, ATP, UTP and nitric oxide affected the haemostatic system as assessed by whole blood thromboelastography (TEG) analysis. Ten pigs received a randomized infusion......Nucleotides, including ADP, ATP and uridine triphosphate (UTP), are discharged profusely in the circulation during many pathological conditions including sepsis. Sepsis can cause hypotension and systemic activation of the coagulation and fibrinolytic systems in humans, which may cause disseminated.......7 ng/ml; P blood was evaluated by TEG. Circulating ADP induces hypocoagulation without signs of increased fibrinolysis as evaluated by TEG. The potential...

  15. Ionization effects in the generation of wake-fields by ultra-high contrast femtosecond laser pulses in argon gas

    Energy Technology Data Exchange (ETDEWEB)

    Makito, K.; Shin, J.-H. [Graduate School of Engineering, Osaka University, 2-1, Yamadaoka, Suita, Osaka (Japan); Zhidkov, A.; Hosokai, T.; Masuda, S. [Photon Pioneers Center, Osaka University, 2-8, Yamadaoka, Suita, Osaka (Japan); Japan Science and Technology Agency (JST), CREST, 2-8 Yamadaoka, Suita, Osaka (Japan); Kodama, R. [Graduate School of Engineering, Osaka University, 2-1, Yamadaoka, Suita, Osaka (Japan); Photon Pioneers Center, Osaka University, 2-8, Yamadaoka, Suita, Osaka (Japan); Japan Science and Technology Agency (JST), CREST, 2-8 Yamadaoka, Suita, Osaka (Japan)

    2012-10-15

    Difference in mechanisms of wake-field generation and electron self-injection by high contrast femtosecond laser pulses in an initially neutral Argon gas and in pre-ionized plasma without ionization is studied via 2D particle-in-cell simulations including optical ionization of the media. For shorter laser pulses, 40 fs, ionization results only in an increase of the charge of accelerated electrons by factor of {approx}3 with qualitatively the same energy distribution. For longer pulses, 80 fs, a more stable wake field structure is observed in the neutral gas with the maximal energy of the accelerated electrons exceeding that in the fixed density plasma. In higher density Argon, an ionizing laser pulse converts itself to a complex system of solitons at a self-induced, critical density ramp.

  16. Ionization effects in the generation of wake-fields by ultra-high contrast femtosecond laser pulses in argon gas

    Science.gov (United States)

    Makito, K.; Zhidkov, A.; Hosokai, T.; Shin, J.-H.; Masuda, S.; Kodama, R.

    2012-10-01

    Difference in mechanisms of wake-field generation and electron self-injection by high contrast femtosecond laser pulses in an initially neutral Argon gas and in pre-ionized plasma without ionization is studied via 2D particle-in-cell simulations including optical ionization of the media. For shorter laser pulses, 40 fs, ionization results only in an increase of the charge of accelerated electrons by factor of ˜3 with qualitatively the same energy distribution. For longer pulses, 80 fs, a more stable wake field structure is observed in the neutral gas with the maximal energy of the accelerated electrons exceeding that in the fixed density plasma. In higher density Argon, an ionizing laser pulse converts itself to a complex system of solitons at a self-induced, critical density ramp.

  17. Effect of rivaroxaban on blood coagulation using the viscoelastic coagulation test ROTEM™.

    Science.gov (United States)

    Casutt, M; Konrad, C; Schuepfer, G

    2012-11-01

    This study investigated the influence of the oral direct inhibitor of factor Xa rivaroxaban on blood coagulation measured by rotation thrombelastometry ROTEM™. Blood was obtained from 11 healthy male volunteers before and 2.5 h after oral administration of 10 mg rivaroxaban. In addition to standard coagulation tests clot formation was measured by ROTEM™ analyzing extrinsic (Extem) and intrinsic thrombelastometry (Intem). Significant differences to the baseline values were found in the Extem clotting time (Extem-CT, 58 ± 9 s and 87 ± 17 s, p coagulation by rivaroxaban.

  18. Self-consistent Kinetic Description of the Low-Pressure Solenoidal Inductively Coupled Argon Discharge

    Institute of Scientific and Technical Information of China (English)

    毛明; 王友年

    2005-01-01

    Using an one-dimensional slab model, we have studied the electron energy distribution, the anomalous skin effect, and power absorption in the solenoidal-inductively-coupled argon discharge under low pressures (≤1.33 Pa). The electron energy distribution function and rf electromagnetic field in the plasma are determined self-consistently by the linearized Bolztmann equation incorporating with the Maxwell equations. The numerical results show that, at low pressures, the electron energy distribution function exhibits a non-Maxwellian distribution with a long high-energy tail. The anomalous skin effect is greatly enhanced under low pressures and the negative power absorption is also obtained.

  19. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  20. Designing plasmas for chronic wound disinfection

    Science.gov (United States)

    Nosenko, T.; Shimizu, T.; Morfill, G. E.

    2009-11-01

    Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.

  1. Simulations with Conventional and Gas Puff Plasma Focus Devices

    Science.gov (United States)

    Shan, Bing; Liu, Mahe; Lee, Paul; Lee, Sing

    2000-10-01

    An energy consistent plasma focus model is improved by considering the plasma ionization states based on the corona equilibrium. This provides the model with the capability of calculating the plasma dynamics and states for different gases in plasma focus. The model is employed to simulate the behavior of the NX2 plasma focus, with both neon and argon gases. The results show that much lower pressure is required to work with argon for x-ray. The model has also been modified to describe a gas-puff plasma focus based on a measured pressure distribution profile. The simulation result reveals that the gas-puff scheme is more efficient in plasma heating and can improve the stability of the plasma column. By comparing with the published results, agreements have been obtained between the computations and experiments of both machines in the major points regarding plasma dynamics, plasma column stability and appearances, plasma temperatures, and x-ray radiation properties.

  2. Mathematical Model of Extrinsic Blood Coagulation Cascade Dynamic System

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The blood coagulation system is very important to life. This paper presents a mathematical blood coagulation model for the extrinsic pathway. This model simulates clotting factor VIII, which plays an important role in the coagulation mechanism. The mathematical model is used to study the equilibrium stability, orbit structure, attractors and global stability behavior, with conclusions in accordance with the physiological phenomena. Moreover, the results provide information about blood related illnesses, which can be used for further study of the coagulation mechanism.

  3. [The implantation of bipolar coagulation to remove endometriosis foci].

    Science.gov (United States)

    Sobkiewicz, S; Palatyński, A; Salata, I

    2001-05-01

    The paper compares the results of bipolar coagulation bey means of ERBE ICC 300 diatermy coagulator and WISAP endocoagulator. The results of both types of coagulation were assessed with reference to the changes occurring on peritoneum ligamenti sacro-uterini, Douglas pouch and ovary. The best results of endometriosis foci coagulation were obtained with bipolar ball at 20-30 W; no side effects or feelings of malaise were observed in patients just after the operation or over a longer period of convalescence.

  4. The relationship between inflammation and the coagulation system

    NARCIS (Netherlands)

    Choi, Goda; Schultz, Marcus J; Levi, Marcel; van der Poll, Tom

    2006-01-01

    Inflammation and coagulation play pivotal roles in host defence. As phylogenetically old responses, there is extensive cross-talk between inflammation and coagulation in enabling an adequate immune response against potentially injurious stimuli. Immune cells are important in the initiation of coagul

  5. The immediate and late effects of thyroid hormone (triiodothyronine on murine coagulation gene transcription.

    Directory of Open Access Journals (Sweden)

    Salam Salloum-Asfar

    Full Text Available Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine (T3 and thyroxine (T4 production. Under these conditions, the impact of exogenous T3 on plasma coagulation, and hepatic and vessel-wall-associated coagulation gene transcription was studied in a short- (4 hours and long-term (14 days setting. Comparing euthyroid conditions (normal mice, with hypothyroidism (conditions of a shortage of thyroid hormone and those with replacement by incremental doses of T3, dosages of 0 and 0.5 μg T3/mouse/day were selected to study the impact of T3 on coagulation gene transcription. Under these conditions, a single injection of T3 injection increased strongly hepatic transcript levels of the well-characterized T3-responsive genes deiodinase type 1 (Dio1 and Spot14 within 4 hours. This coincided with significantly reduced mRNA levels of Fgg, Serpinc1, Proc, Proz, and Serpin10, and the reduction of the latter three persisted upon daily treatment with T3 for 14 days. Prolonged T3 treatment induced a significant down-regulation in factor (F 2, F9 and F10 transcript levels, while F11 and F12 levels increased. Activity levels in plasma largely paralleled these mRNA changes. Thbd transcript levels in the lung (vessel-wall-associated coagulation were significantly up-regulated after a single T3 injection, and persisted upon prolonged T3 exposure. Two-week T3 administration also resulted in increased Vwf and Tfpi mRNA levels, whereas Tf levels decreased. These data showed that T3 has specific effects on coagulation, with Fgg, Serpinc1, Proc, Proz, Serpin10 and Thbd responding rapidly, making these likely direct thyroid hormone receptor targets. F2, F9, F10, F11, F12, Vwf, Tf and Tfpi are late responding genes and probably

  6. Diagnosis of overt disseminated intravascular coagulation in critically Ill adults by Sonoclot coagulation analysis.

    Science.gov (United States)

    Wan, Peng; Tong, Hua-Sheng; Zhang, Xing-Qin; Duan, Peng-Kai; Tang, You-Qing; Su, Lei

    2014-08-01

    Disseminated intravascular coagulation (DIC) diagnosis is hampered by the limited availability of reliable clinical or laboratory tests. Currently available tests are time consuming and expensive. We investigated whether coagulation and platelet function analyses using the Sonoclot system were suitable for overt DIC diagnosis in critically ill adults. This was an observational diagnostic study performed in 498 patients presenting with an underlying disorder associated with DIC. Overt DIC patients were identified according to an International Society on Thrombosis and Hemostasis (ISTH) score of >5. Coagulation and platelet parameters were analyzed using the Sonoclot system, and compared with ISTH as the gold standard. Receiver operating characteristic curves and area under the curves were used to evaluate the value of the Sonoclot parameters. There were no differences for age or gender between the groups. Significant correlations were observed between activated clotting time (ACT) and ISTH score (r = 0.7; P coagulation dysfunction in patients with overt DIC.

  7. Coagulation disorders in the patients with deep vein thrombosis of lower extremity

    Directory of Open Access Journals (Sweden)

    Milić Dragan J.

    2003-01-01

    Full Text Available PURPOSE Venous thromboembolism is a relevant social and health care problem for its high incidence, pulmonary embolism-related mortality and long-term sequelae which may be disabling (post-thrombotic syndrome and ulceration. PROCEDURES The aim of our work was to establish the presence of coagulation disorders (hypercoagulable states in the patients with deep vein thrombosis (DVT of the leg. Prospectively we have analyzed a group of 30 patients with echosono-graphicaly verified DVT of the leg who were admitted to the department of vascular surgery from August 1st 2000 to July 31st 2001.The following parameters were monitored: prothrombin time (PT partial thromboplastin time (PTT, fibrinogen (Fib, alpha 2 antiplasmin (A-2 AP, D-dimer (DD, antithrombin III (AT III and factor VII. FINDINGS Activation of the coagulation process was registered. The values of monitored coagulation parameters are shown in table 1. Plasma levels of monitored parameters in the patients with DVT of the leg were significantly higher than in the control subjects. CONCLUSION In patients with a DVT a hypercoagulable state is common finding. Some parameters of coagulation activity such as D-dimer might be of great interest in the diagnostic strategy of DVT.

  8. Roles for vitamin K beyond coagulation

    Science.gov (United States)

    Recent interest in vitamin K has been motivated by evidence of physiological roles beyond that of coagulation. Vitamin K and vitamin K-dependent proteins may be involved in regulation of calcification, energy metabolism, and inflammation. However, the evidence for many of these proposed roles in the...

  9. Brownian coagulation at high particle concentrations

    NARCIS (Netherlands)

    Trzeciak, T. M.

    2012-01-01

    The process of Brownian coagulation, whereby particles are brought together by thermal motion and grow by collisions, is one of the most fundamental processes influencing the final properties of particulate matter in a variety of technically important systems. It is of importance in colloids, emulsi

  10. Genetically determined coagulation disorders in ischemic stroke

    NARCIS (Netherlands)

    M.P.J. van Goor (Marie-Louise)

    2004-01-01

    textabstractThe aim of the research described in this thesis was to investigate the role of genetically determined coagulation disorders in ischemic stroke. We therefore performed several retrospective studies and one prospective case-control study of patients with recent ischemic stroke (the COCOS

  11. Laboratory testing in disseminated intravascular coagulation.

    Science.gov (United States)

    Favaloro, Emmanuel J

    2010-06-01

    The diagnosis of disseminated intravascular coagulation (DIC) relies on clinical signs and symptoms, identification of the underlying disease, the results of laboratory testing, and differentiation from other pathologies. The clinical features mainly depend on the underlying cause of the DIC. The laboratory diagnosis of DIC uses a combination of tests because no single test result alone can firmly establish or rule out the diagnosis. Global tests of hemostasis may initially provide evidence of coagulation activation and later in the process provide evidence of consumption of coagulation factors, but their individual diagnostic efficiency is limited. Fibrinolytic markers, in particular D-dimer, are reflective of activation of both coagulation and fibrinolysis, so that a normal finding can be useful for ruling-out DIC. Decreased levels of the natural anticoagulants (in particular, antithrombin and protein C) are frequently observed in patients with DIC, but their measurement is not normally incorporated into standard diagnostic algorithms. New tests are being explored for utility in DIC, and some additional tests may be useful on a case-by-case basis, depending on the proposed cause of the DIC or their local availability. For example, clot waveform analysis is useful but currently limited to a single instrument. Also, procalcitonin is an inflammatory biomarker that may be useful within the context of septic DIC, and activated factor X clotting time is an emerging test of procoagulant phospholipids that also seems to hold promise in DIC.

  12. Blood coagulation: hemostasis and thrombin regulation.

    Science.gov (United States)

    Tanaka, Kenichi A; Key, Nigel S; Levy, Jerrold H

    2009-05-01

    Perioperative bleeding is a major challenge particularly because of increasing clinical use of potent antithrombotic drugs. Understanding current concepts of coagulation is important in determining the preoperative bleeding risk of patients, and in managing hemostatic therapy perioperatively. The serine protease thrombin plays pivotal roles in the activation of additional serine protease zymogens (inactive enzymatic precursors), cofactors, and cell-surface receptors. Thrombin generation is closely regulated to locally achieve rapid hemostasis after injury without causing uncontrolled systemic thrombosis. During surgery, there are major disturbances in coagulation and inflammatory systems because of hemorrhage/hemodilution, blood transfusion, and surgical stresses. Postoperative bleeding often requires allogeneic blood transfusions, which support thrombin generation and hemostasis. However, procoagulant activity and inflammation are increased postoperatively; thus, antithrombotic therapy may be required to prevent perioperative thrombotic complications. There have been significant advances in the management of perioperative hemostasis and thrombosis because of the introduction of novel hemostatic and antithrombotic drugs. However, a limitation of current treatment is that conventional clotting tests do not reflect the entire physiological processes of coagulation making optimal pharmacologic therapy difficult. Understanding the in vivo regulatory mechanisms and pharmacologic modulation of thrombin generation may help control bleeding without potentially increasing prothrombotic risks. In this review, we focus on the regulatory mechanisms of hemostasis and thrombin generation using multiple, simplified models of coagulation.

  13. Blood coagulation factor VIII: An overview

    Indian Academy of Sciences (India)

    G M Bhopale; R K Nanda

    2003-12-01

    Factor VIII (FVIII) functions as a co-factor in the blood coagulation cascade for the proteolytic activation of factor X by factor IXa. Deficiency of FVIII causes hemophilia A, the most commonly inherited bleeding disorder. This review highlights current knowledge on selected aspects of FVIII in which both the scientist and the clinician should be interested.

  14. Argon laser induced changes to the carbonate content of enamel

    Energy Technology Data Exchange (ETDEWEB)

    Ziglo, M.J. [Orthodontic Graduate Program, Faculty of Medicine and Dentistry, University of Alberta, Private Practice, Regina, Saskatchewan (Canada); Nelson, A.E., E-mail: aenelson@dow.com [Department of Chemical and Materials Engineering, Faculty of Engineering, University of Alberta (Canada); Heo, G.; Major, P.W. [Orthodontic Graduate Program, Faculty of Medicine and Dentistry, University of Alberta (Canada)

    2009-05-15

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm{sup -2}) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  15. Clinical effect of co-infusion of fresh frozen plasma and cryoprecipitate on blood coagulation function in patients with postpartum hemorrhage%新鲜冰冻血浆联合冷沉淀输注对产后大出血患者凝血功能影响

    Institute of Scientific and Technical Information of China (English)

    陈涌泉; 王厚照; 吕小英; 张毓

    2015-01-01

    Objective: To observe the clinical effect of co-infusion of fresh frozen plasma(FFP) and cryoprecipitate(Cryo) to raise the levels of fibrinogen(Fbg)and fibronectin(Fn)in patients with postpartum hemorrhage. Methods: Patients with postpartum hemorrhage were randomly divided into three groups , Group A: FFP and Cryo co-infusion group( n=25), Group B:FFP infusion group( n=23), Group C:Cryo infusion group( n=24). The levels of Fbg and Fn were determined 1 hour before infusion and 3-12 hours after infusion. Results: Compared to the FFP infusion group and Cryo infusion group, the levels of Fbg and Fn of FFP and Cryo co-infusion group were both significantly higher with the changes containing statistical significance. Conclusion: FFP and Cryo co-infusion could significantly raise the levels of Fbg and Fn in patients with postpartum hemorrhage, which could improve their coagulation functions and promote their hemostatic functions.%目的:观察新鲜冰冻血浆(FFP)和冷沉淀(Cryo)联合输注提升产后大出血患者血液中纤维蛋白原(Fbg)和纤维结合蛋白(Fn)水平的临床效果。方法:72例产后大出血患者分为3组, A 组:FFP 联合 Cryo 输注组(共25例),B 组:FFP 输注组(共23例),C 组:Cryo 输注组(共24例)。输注前1h 和输注后3~12h 测定血液中 Fbg 和 Fn 含量。结果:与 FFP 输注组和 Cryo 输注组相比,FFP 联合 Cryo 输注组输注后 Fbg 和 Fn 含量均明显上升,差异有统计学意义(P<0.05)。结论:FFP 和 Cryo 联合输注比单独输注 FFP 或 Cryo 更能有效提升患者血液中 Fbg 和 Fn 含量,改善大出血产妇凝血功能状况和促进止血。

  16. Optimized coagulation of high alkalinity, low temperature and particle water: pH adjustment and polyelectrolytes as coagulant aids.

    Science.gov (United States)

    Yu, Jianfeng; Wang, Dongsheng; Yan, Mingquan; Ye, Changqing; Yang, Min; Ge, Xiaopeng

    2007-08-01

    The Yellow River in winter as source water is characterized as high alkalinity, low temperature and low particle concentrations, which have brought many difficulties to water treatment plants. This study fully examines the optimized coagulation process of the Yellow River by conventional and pre-polymerized metal coagulants, pH adjustment and polyelectrolytes as the primary coagulants or coagulant aids. For all the metal coagulants, polyaluminum chlorides are superior to traditional metal coagulants due to their stable polymeric species and low consumption of alkalinity. The removal of natural organic matter by monomeric metal coagulants can be improved through pH adjustment, which is in accordance with the higher concentration of polymeric species formed at corresponding pH value. With the addition of polyelectrolytes as coagulant aids, the coagulation performance is significantly improved. The effective removal of dissolved organic matter is consistent with high charge density, while molecular weight is relatively important for removing particles, which is consistent with polyelectrolytes as primary coagulants. These results suggest that the coagulation mechanisms in the removal of dissolved organic matter and particles are different, which may be exploited for optimized coagulation for the typical source water in practice.

  17. Surface treatment of polypropylene (PP) film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

    Science.gov (United States)

    Joshi, Ujjwal Man; Subedi, Deepak Prasad

    2015-07-01

    Thin films of polypropylene (PP) are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. PP samples before and after the treatments are studied using contact angle measurements, surface free energy calculations and scanning electron microscopy (SEM). Distilled water (H2O), glycerol (C3H8O3) and diiodomethane (CH2I2) are used as test liquids. The contact angle measurements between test liquids and PP samples are used to determine total surface free energy using sessile drop technique. PP films show a remarkable increase in surface free energy after plasma treatment. SEM analysis of the plasma-treated PP films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.

  18. Surface treatment of high density polyethylene (HDPE film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

    Directory of Open Access Journals (Sweden)

    Joshi Ujjwal Man

    2015-03-01

    Full Text Available Thin films of high density polyethylene (HDPE are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. HDPE samples before and after the treatment are studied using contact angle measurements, surface free energy calculations and atomic force microscopy (AFM. Distilled water (H2O, glycerol (C3H8O3 and diiodomethane (CH2I2 are used as test liquids. The contact angle measurements between test liquids and HDPE samples are used to determine total surface free energy using sessile drop technique. HDPE films show a remarkable increase in surface free energy after plasma treatment. AFM analysis of the plasma-treated HDPE films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.

  19. Study on the removal of acid dyes using chitosan as a natural coagulant/coagulant aid.

    Science.gov (United States)

    Zonoozi, M H; Alavi Moghaddam, M R; Arami, M

    2011-01-01

    Chitosan was selected as a natural coagulating agent for the removal of acid dyes (Acid Blue 292; AB292, and Acid Red 398; AR398) from dye-containing solutions. The study was organised in two phases. In phase 1, chitosan was used alone as a natural coagulant for the removal of the dyes. For this purpose, the effect of different parameters including pH, chitosan dosage and initial dye concentration on the dye removal efficiency was examined. In phase 2 of the study, the application of chitosan as a natural coagulant aid in conjunction with polyaluminium chloride (PAC) was assessed. According to the results of phase 1, the best removal efficiencies occurred in an acidic pH range (less than 6) for both of the dyes. Also, excellent dye removal results (about 90%) were achieved with relatively low dosages of chitosan (30-35 mg L(-1) for AB292 and 50-60 mg L(-1) for AR398). However, the initial concentration of the dyes severely influenced the coagulation performance of chitosan, which can constrain the performance of chitosan as a natural coagulant. On the basis of the results of phase 2, chitosan, as a natural coagulant aid, noticeably enhanced the dye removal efficiency of PAC, especially in the case of AB292. Small amounts of chitosan (3 or 5 mg L(-1)) enhanced the dye removal efficiency of PAC up to 2.5 times for AB292.

  20. Improvement of paint effluents coagulation using natural and synthetic coagulant aids.

    Science.gov (United States)

    Aboulhassan, M A; Souabi, S; Yaacoubi, A; Baudu, M

    2006-11-01

    The coagulant iron chloride and the flocculants Polysep 3000 (PO), Superfloc A-1820 (SU) and Praestol 2515 TR (PR) have been used in this study to show the efficiency of coagulation flocculation process in the chemical precipitation method for the removal of organic and colouring matters from the paint industry wastewater. This study also includes the amount of produced sludge. The results indicate that FeCl(3) is efficient at pH range 8-9 and at optimal dose of 650 mgl(-1). Iron chloride allows the removal of 82% of chemical oxygen demand (COD) and 94% of colour. However, sequential addition of coagulant and polymeric additives enhance clearly pollutant removal and produces less decanted sludge compared to the results obtained when the coagulant is used alone. The removal efficiency of COD reaches 91% and that of colour 99%. Coagulation-biflocculation process is more effective than the coagulation-monoflocculation one. The sequential addition of iron chloride, Polysep 3000 (cationic flocculant) and Praestol 2515 TR (anionic flocculant) seems to be the most suitable combination for the treatment of the paint industry wastewaters.

  1. Simplifying plasma chemistry via ILDM

    Science.gov (United States)

    Rehman, T.; Kemaneci, E.; Graef, W.; van Dijk, J.

    2016-02-01

    A plasma fluid model containing a large number of chemical species and reactions yields a high computational load. One of the methods to overcome this difficulty is to apply Chemical Reduction Techniques as used in combustion engineering. The chemical reduction technique that we study here is ILDM (Intrinsic Lower Dimensional Manifold). The ILDM method is used to simplify an argon plasma model and then a comparison is made with a CRM (Collisional Radiative Model).

  2. Upper gastrointestinal bleeding from duodenal vascular ectasia in a patient with cirrhosis

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    We report a cirrhotic patient with duodenal vascular ectasia and spontaneous bleeding. The bleeding was successfully controlled with argon plasma coagulation.Duodenal vascular ectasia may be a cause of upper gastrointestinal bleeding in patients with cirrhosis, and argon plasma coagulation may be effective and safe to achieve hemostasis of this lesion.

  3. Practical reactor production of {sup 41}Ar from argon clathrate

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, J.R. E-mail: jmercer@pharmacy.ualberta.ca; Duke, M.J.M.; McQuarrie, S.A

    2000-06-01

    The radionuclide {sup 41}Ar has many ideal properties as a gas flow tracer. However, the modest cross-section of {sup 40}Ar for thermal neutron activation makes preparation of suitable activities of {sup 41}Ar technically difficult particularly for low flux reactors. Argon can however be trapped in a molecular complex called a clathrate that can then be irradiated. We prepared argon clathrate and explored its irradiation and stability characteristics. Argon clathrate can be used to provide gigabecquerel quantities of {sup 41}Ar even with low power reactors.

  4. Modeling Electronegative Impurity Concentrations in Liquid Argon Detectors

    Science.gov (United States)

    Tang, Wei; Li, Yichen; Thorn, Craig; Qian, Xin

    2017-01-01

    Achieving long electron lifetime is crucial to reach the high performance of large Liquid Argon Time Projection Chamber (LArTPC) envisioned for next generation neutrino experiments. We have built up a quantitative model to describe the impurity distribution and transportation in a cryostat. Henrys constants of Oxygen and water, which describe the partition of impurities between gas argon and liquid argon, have been deduced through this model with the measurements in BNL 20-L LAr test stand. These results indicate the importance of the gas purification system and prospects on large LArTPC detectors will be discussed.

  5. Unidentified coagulation disorders in post-tonsillectomy hemorrhage.

    Science.gov (United States)

    Windfuhr, Jochen P; Chen, Yue-Shih; Remmert, Stephan

    2004-01-01

    We conducted a retrospective study of 6,966 patients who had undergone tonsillectomy or adenotonsillectomy to evaluate the incidence and clinical features of previously unidentified coagulation disorders in patients who experienced postoperative hemorrhage (n = 201). We found that post-tonsillectomy hemorrhage secondary to unidentified coagulation disorders is extremely rare. However, normal coagulation values and an insignificant history do not rule out coagulation disorders. If diffuse, persistent, and bilateral bleeding is not related to arterial hypertension, dissection technique, or local infection, a rapid and detailed analysis of coagulation factors should be considered.

  6. 早发型重度子痫前期合并器官功能障碍患者可溶性内皮抑素、内皮素-1与凝血功能的变化及意义%Serum soluble Endoglin, plasma endothelin-1 and coagulation function in early onset severe preeclampsia with organ dysfunction

    Institute of Scientific and Technical Information of China (English)

    张立军; 韩玉环; 韩玉植

    2010-01-01

    Objective To investigate the expression levels of serum soluble Endoglin (sEng), plasma endothelin-1 (ET-1) and coagulation function in patients suffering from early onset severe preeclampsia with organ dysfunction, and to analyze the clinical significance. Methods Forty-nine early onset severe preeclampsia patients were enrolled in the study group, including 26 cases without organ dysfunction (study group Ⅰ) and 23 cases with organ dysfunction (study group Ⅱ). The control group included 30 cases of health pregnant women during the same period of gestation. The serum levels of sEng and plasma ET-1 were analyzed with enzyme-linked immunosorbent assay (ELISA), coagulation function was determined at the same time, and the relationship between the change in levels of sEng, ET-1, coagulation function and organ function, and also outcome of perinatal infants. Results ① The levels of sEng, ET-1, fibrinogen (Fib) and mean platelet volume (MPV) of the study group Ⅰ and I were significantly higher compared with control group (sEng,μg/L:10.96±3.21, 14.17±4.02vs. 7.49±2.73; ET-1, μg/L: 41.54 ± 10. 37, 65.91± 12.46vs. 24.56±6.26; Fib, g/L:4.41±1.02,5.35±1.17vs. 3.69±0.82; MPV, fl:11. 71± 1.21, 13.89±1.76vs. 11.03±0.82, all P< 0.05), and prothrombin time (PT), activated partial thromboplastin time (APTT) and platelet (PLT) were significantly lower compared with control group (PT, s:10.73±1.82, 8.37±1.51vs. 12.95±1.91; APTT, s:26.14±4.32, 22.69±3.77vs. 30.25±4.71; PLT,×109/L; 164.17±50.67, 136.43±51.21vs. 201.63±59.83, all P<0.05). There were also statistical significances in all the values between study group Ⅰ and I (all P<0.05). ②There was positive correlation between the sEng level and systolic pressure, diastolic pressure, Fib, urine protein of 24 hours, serum creatinine (SCr); there was negative correlation between the sEng level and albumin (Alb) content, PT, estriol/creatinine (E/C) of 12-hour urine, fetal birth weight (all P

  7. Diagnostics of Nanodusty Plasma

    Science.gov (United States)

    Greiner, Franko; Groth, Sebastian; Tadsen, Bejamin; Piel, Alexander

    2015-11-01

    The diagnostic of nanodusty plasmas, i.e. plasmas including nano-sized dust particles, is a challenging task. For both, the diagnostic of the nanodusty plasma itself, and the in-situ diagnostic of the nanoparticles, no standard diagnostic exist. Nanodust particle size and density can be estimated using light scattering techniques, namely kinetic Mie ellipsometry and extinction measurements. The charge of the nanoparticles can be estimated from the analysis of dust density waves (DDW). Parameters like the electron density, which give information about the plasma itself, may be deduced from the DDW analysis. We present detailed investigations on nanodust in a reactive Argon-Acetylene plasma created in an rf-driven parallel plate reactor at low pressure using the above mentioned portfolio of diagnostic. Funded by DFG under contract SFB TR-24/A2.

  8. Parameters of atmospheric plasmas produced by electrosurgical devices

    Science.gov (United States)

    Keidar, Michael; Shashurin, Alexey; Canady, Jerome

    2013-10-01

    Electrosurgical systems are extensively utilized in general surgery, surgical oncology, plastic and reconstructive surgery etc. In this work we study plasma parameters created by electrosurgical system SS-200E/Argon 2 of US Medical Innovations. The maximal length of the discharge plasma column at which the discharge can be sustained was determined as function of discharge power and argon flow rate. Electrical parameters including discharge current and voltage were measured. Recently proposed Rayleigh microwave scattering method for temporally resolved density measurements of small-size atmospheric plasmas was utilized. Simultaneously, evolution of plasma column was observed using intensified charge-coupled device (ICCD) camera.

  9. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    degrees C and evidence was found for the solidification of the melt at 380-440 degrees C, i.e. simultaneously with the onset of decomposition. Between 400 degrees C and 520 degrees C (Ba(C4H9CO2)(2) decomposes in two main steps, first into BaCO3 with release of C4H9COC4H9 (5-nonanone), whereas final......The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...... conversion to BaO takes place with release of CO2. Elemental carbon that is left as a by-product is finally slowly burned by the residual oxygen present in the Ar atmosphere. (C) 2015 Elsevier B.V. All rights reserved....

  10. Liquid argon calorimeter performance at high rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2012-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $10^{12}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  11. Electron avalanches in liquid argon mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.G.; Dardin, S.M.; Kadel, R.W.; Kadyk, J.A.; Wenzel, W.B.; Peskov, V.

    2004-03-19

    We have observed stable avalanche gain in liquid argon when mixed with small amounts of xenon in the high electric field (>7 MV/cm) near the point of a chemically etched needle in a point-plane geometry. We identify two gain mechanisms, one pressure dependent, and the other independent of the applied pressure. We conclude that the pressure dependent signals are from avalanche gain in gas bubbles at the tip of the needle, while the pressure independent pulses are from avalanche gain in liquid. We measure the decay time spectra of photons from both types of avalanches. The decay times from the pressure dependent pulses decrease (increase) with the applied pressure (high voltage), while the decay times from the pressure independent pulses are approximately independent of pressure or high voltage. For our operating conditions, the collected charge distribution from avalanches is similar for 60 keV or 122 keV photon sources. With krypton additives, instead of Xe, we measure behavior consistent with only the pressure dependent pulses. Neon and TMS were also investigated as additives, and designs for practical detectors were tested.

  12. Liquid Argon Calorimeter performance at High Rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2013-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $3\\cdot10^{11}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  13. A Study of the Residual 39Ar Content in Argon from Underground Sources

    CERN Document Server

    Xu, J; Galbiati, C; Goretti, A; Guray, G; Hohman, T; Holtz, D; Ianni, A; Laubenstein, M; Loer, B; Love, C; Martoff, C J; Montanari, D; Mukhopadhyay, S; Nelson, A; Rountree, S D; Vogelaar, R B; Wright, A

    2012-01-01

    The discovery of argon from underground sources with significantly less 39Ar than atmospheric argon was an important step in the development of direct-detection dark matter experiments using argon as the active target. We report on the design and operation of a low background detector with a single phase liquid argon target that was built to study the 39Ar content of the underground argon. Underground argon from the Kinder Morgan CO2 plant in Cortez, Colorado was determined to have less than 0.65% of the 39Ar activity in atmospheric argon.

  14. Theory of gas discharge plasma

    CERN Document Server

    Smirnov, Boris M

    2015-01-01

    This book presents the theory of gas discharge plasmas in a didactical way. It explains the processes in gas discharge plasmas. A gas discharge plasma is an ionized gas which is supported by an external electric field. Therefore its parameters are determined by processes in it. The properties of a gas discharge plasma depend on its gas component, types of external fields, their geometry and regimes of gas discharge. Fundamentals of a gas discharge plasma include elementary, radiative and transport processes which are included in its kinetics influence. They are represented in this book together with the analysis of simple gas discharges. These general principles are applied to stationary gas discharge plasmas of helium and argon. The analysis of such plasmas under certain conditions is theoretically determined by numerical plasma parameters for given regimes and conditions.

  15. Size Determination of Argon Clusters from a Rayleigh Scattering Experiment

    Institute of Scientific and Technical Information of China (English)

    LEI An-Le; ZHAI Hua-Jin; LIU Bing-Chen; LI Zhong; NI Guo-Yuan; XU Zhi-Zhan

    2000-01-01

    Argon clusters are produced in the process of adiabatic expansion of a high backing pressure gas into vacuum through a nozzle. The cluster size is determined by a Rayleigh scattering measurement. The scattered signal measured is proportional to the 2.78th power of gas stagnation pressure. The average cluster sizes vary from 100 to more than 12000 atoms/cluster with the argon gas backing pressures ranging between 3 to 45 atm.

  16. Evaluation of the process of coagulation/flocculation of produced water using Moringa oleifera Lam. as natural coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Santana, C.R.; Pereira, D.F.; Sousa, S.C S N.; Silva, G.F. [Universidade Federal de Sergipe (UFSE), Sao Cristovao, SE (Brazil). Dept. de Engenharia Quimica], e-mail: claudia@ufs.br; Cavalcanti, E.B. [Universidade Tiradentes (UNIT), SE (Brazil). Inst. de Tecnologia e Pesquisa

    2010-07-15

    In the lifetime of an oil well, there comes a moment when a lot of water begins to be produced along with oil, either by the conditions of the reservoir, or as a result of water injection in the secondary recovery of the well. An important step in such process involves the treatment of the produced water by means of coagulation techniques. Therefore, the use of environmentally correct coagulants is presented as a viable alternative and has demonstrated advantages over the use of chemical coagulants. The plant of the genus Moringa, whose species is oleifera Lam, stands out as one of the most promising natural coagulants. The present study investigated the evaluation of the coagulation/flocculation of produced water, using seeds of Moringa oleifera Lam. as coagulant. The results were very significant, demonstrating that Moringa oleifera Lam. can be used as a natural coagulant in this type of treatment. (author)

  17. 维生素K1、新鲜冰冻血浆和冷沉淀对不同出生胎龄新生儿凝血指标的影响%Effects of vitamin k1, fresh frozen plasma and cryoprecipitate on coagulation index of newborns with different gestational ages

    Institute of Scientific and Technical Information of China (English)

    张涛; 廖嘉仪; 张费通; 谭小华; 崔其亮

    2014-01-01

    Objective To explore the effect of Vitamin K1(Vit K1), fresh frozen plasma (plasma) andcryoprecipitate on prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen original(Fbg), thrombin time (TT) of newborns with different gestational ages. Methods The serum of 1,134 newbornsfrom The Third Affiliated Hospital of Guangzhou Medical University was collected from February 2009 to September2012. All newborns had been divided into four groups (according to the gestational age of 28-31+6 weeks, 32-33+6weeks, 34-36+6 weeks and gestational age≥37 weeks).The effect of various interventions (Vit K1, Vit K1+plasmaand Vit K1+cryoprecipitate) on PT, APTT, Fbg, and TT had been recorded. Results (1)The PT and APTT ofeach group with the interventions of Vit k1 were significantly improved (P < 0.05). (2)The PT, APTT, Fbg and TTof each group with the interventions of Vit k1 combined with plasma were significantly improved (P < 0.05). (3)ThePT, APTT and Fbg of each group with the interventions of Vit k1 combined with cryoprecipitate were significantlyimproved (P < 0.05). (4)With Vit k1 combined with plasma, PT and APTT were mostly improved and Fbg wasimproved mostly with Vit k1 combined with cryoprecipitate. Conclusion Vitamin K1, fresh frozen plasma andcryoprecipitate can effectively improvedin the coagulation index of newborns with different gestational ages.%目的:回顾性分析不同出生胎龄新生儿应用维生素K1(Vitamin K1,Vit K1)、新鲜冰冻血浆(血浆)和冷沉淀对凝血酶原时间(PT)、部分活化凝血活酶时间(APTT)、纤维蛋白原(Fbg)、凝血酶时间(TT)的影响。方法:收集广州医科大学附属第三医院2009年2月至2012年9月新生儿科住院的新生儿1134例,按照胎龄28-31+6周、32-33+6周、胎龄34-36+6周、胎龄≥37周进行分组,每组均分析使用Vit K1、Vit K1联合血浆以及Vit K1联合冷沉淀等干预措施前后PT、APTT

  18. Can dust coagulation trigger streaming instability?

    CERN Document Server

    Drazkowska, Joanna

    2014-01-01

    Streaming instability can be a very efficient way of overcoming growth and drift barriers to planetesimal formation. However, it was shown that strong clumping, which leads to planetesimal formation, requires a considerable number of large grains. State-of-the-art streaming instability models do not take into account realistic size distributions resulting from the collisional evolution of dust. We investigate whether a sufficient quantity of large aggregates can be produced by sticking and what the interplay of dust coagulation and planetesimal formation is. We develop a semi-analytical prescription of planetesimal formation by streaming instability and implement it in our dust coagulation code based on the Monte Carlo algorithm with the representative particles approach. We find that planetesimal formation by streaming instability may preferentially work outside the snow line, where sticky icy aggregates are present. The efficiency of the process depends strongly on local dust abundance and radial pressure g...

  19. EFFECTS OF ORAL CONTRACEPTIVES ON COAGULATING FACTORS

    Directory of Open Access Journals (Sweden)

    H.R. Sadeghipour Roudsari.

    1997-06-01

    Full Text Available Thirty young, healthy, nonsmoking women (mean age approximately 28 years taking low-dose oral contraceptive pills were recruited for the study of the effects of these pills on coagulating factors. Twenty subjects were taking LD pill (Ethinyl estradiol 0.03 mg, levonorgestrel 0.15 mg and 10 others were taking Cilest (Ethinyl estradiol 0.035 mg, Norgestimate 0.25 mg for six months. The control subjects did not receive any oral contraceptives or other medications. Our results showed that:"n1. There is no significant difference between the effects of LD and Cilest (with a different progestin content on coagulating factors."n2. No significant changes were observed between both LD users and controls in PT, APTT, and fibrinogen levels."n3. No significant changes were observed between both Cilest users and controls in PT, APTT, and fibrinogen levels."n

  20. Monitoring Oral Anticoagulant Therapy: Measuring Coagulant Activity

    DEFF Research Database (Denmark)

    Attermann, Jorn

    daily anticoagulant therapy. The therapy necessitates close monitoring of coagulant activity, since excess doses of anticoagulant medicine may lead to life-threatening bleedings. Traditionally, patients on OAT are required to pay regular visits to a physician, who decides on drug dosage adjustments...... of the new concept is the training and continuous support and monitoring of the patients, and a center with these purposes has been established at Skejby Sygehus. The main instrument for monitoring the coagulant activity is the prothrombin time (PT). This is the time until clotting can be observed...... central aspects of the INR system, such as the inaccuracy of INR estimates based on a given path of calibrations. The main result states that, under weak regularity conditions, log (log (estimated INR)) is approximately normally distributed with mean log (log (true INR)). The variance is a function...

  1. Self-similar behavior for multicomponent coagulation

    Institute of Scientific and Technical Information of China (English)

    杨曼丽; 卢志明; 刘宇陆

    2014-01-01

    Self-similar behavior for the multicomponent coagulation system is investi-gated analytically in this paper. Asymptotic self-similar solutions for the constant ker-nel, sum kernel, and product kernel are achieved by introduction of different generating functions. In these solutions, two size-scale variables are introduced to characterize the asymptotic distribution of total mass and individual masses. The result of product kernel (gelling kernel) is consistent with the Vigli-Ziff conjecture to some extent. Furthermore, the steady-state solution with injection for the constant kernel is obtained, which is again the product of a normal distribution and the scaling solution for the single variable coag-ulation.

  2. [Disseminated intravascular coagulation: clinical and biological diagnosis].

    Science.gov (United States)

    Touaoussa, Aziz; El Youssi, Hind; El Hassani, Imane; Hanouf, Daham; El Bergui, Imane; Zoulati, Ghizlane; Amrani Hassani, Moncef

    2015-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by the systemic activation of blood coagulation. Its pathophysiological mechanisms are complex and dependent on the underlying pathology, making the clinical and biological expression of quite variable DIC. Among the various biological parameters disrupted, most are not specific, and none of them allows in itself to make the diagnosis. All this does not facilitate the task of the practitioner for diagnosis of overt DIC, much less that of the non-overt DIC, early stage whose treatment would improve the prognosis. These considerations have led to develop scores, combining several parameters depending on their availability in daily practice, as well as their diagnostic relevance. Of all the scores, the ISTH (International society of thrombosis and hemostasis) remains the most used.

  3. Changes in coagulation and lytic activity of the blood and tissues at the pelvic trauma during anticoagulant therapy

    Directory of Open Access Journals (Sweden)

    A. P. Vlasov

    2014-01-01

    Full Text Available The purpose of our study was exploration of coagulation and lytic activity in blood and tissues during anticoagulation therapy in the early posttraumatic period in patients with pelvic bone fracture. The study was based on experiment researches using methods allowing to estimate coagulation activity in different tissues (skeletal muscles, liver, kidneys, heart, lungs and blood at pelvic trauma during anticoagulation therapy. It was established that at pelvic trauma using anticoagulation therapy (fraxiparine leads to hemostatic system modification in the early posttraumatic period. We observed fast decrease of a hypercoagulability in a blood plasma (organism level and growth fibrinolytic activity. In liver, kidneys, heart and lungs tissues (organ level we also registered correction the hemostatic disorders. However, the rate of these recovery processes in tissues is lower than in the blood. Especially low it was in skeletal muscles in the area of injury. Thus, it is proved that anticoagulant therapy at a pelvic trauma affects on the extrinsic coagulation pathway less than on the intrinsic coagulation pathway. The established regularity explains the risks of coagulation abnormalities in the early posttraumatic period during anticoagulation treatment.

  4. Development of coagulation regulatory proteins in the fetal and neonatal lamb.

    Science.gov (United States)

    Manco-Johnson, Marilyn J; Jacobson, Linda J; Hacker, Michele R; Townsend, Susan F; Murphy, James; Hay, William

    2002-10-01

    To investigate the development of coagulation regulatory proteins-protein C (PC), protein S (PS), and antithrombin (AT)-in relationship to the procoagulant protein factor X (FX), a chronically catheterized fetal ovine model was used. Infusion and sampling catheters were placed into pregnant ewes and their fetuses and maintained from mid-gestation. From a total of 110 fetuses, 17 lambs, and 63 ewes that were studied on one to 15 occasions, 212 fetal, 88 neonatal, and 157 maternal samples were obtained. Liver tissue was obtained from 31 fetuses and 15 ewes. Plasma levels of all proteins studied were higher in the ewe than in the fetus (p 0.05). This study suggests that fetal regulation of coagulation proteins follows characteristic patterns relative to the vitamin K dependence of the protein rather than its role as a procoagulant versus regulatory protein.

  5. Size-dependent effects of nanoparticles on enzymes in the blood coagulation cascade.

    Science.gov (United States)

    Sanfins, Elodie; Augustsson, Cecilia; Dahlbäck, Björn; Linse, Sara; Cedervall, Tommy

    2014-08-13

    Nanoparticles (NPs) are increasingly used in diagnostic and drug delivery. After entering the bloodstream, a protein corona will form around NPs. The size and curvature of NPs is one of the major characteristics affecting the composition of bound protein in the corona. Key initiators of the intrinsic pathway of blood coagulation, the contact activation complex, (Kallikrein, Factor XII, and high molecular weight Kininogen) have previously been identified on NPs surfaces. We show that the functional impact of carboxyl-modified polystyrene NPs on these initiators of the intrinsic pathway is size dependent. NPs with high curvature affect the enzymatic activity differently from NPs with low curvature. The size dependency is evident in full blood plasma as well as in solutions of single coagulation factors. NPs induce significant alteration of the enzymatic activity in a size-dependent manner, and enzyme kinetics studies show a critical role for NPs surface area and curvature.

  6. Disseminated intravascular coagulation or acute coagulopathy of trauma shock early after trauma? A prospective observational study

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Sorensen, Anne Marie; Perner, Anders;

    2011-01-01

    ABSTRACT: INTRODUCTION: It is debated whether the early trauma induced coagulopathy (TIC) in severely injured patients reflects disseminated intravascular coagulation (DIC) with a fibrinolytic phenotype, acute coagulopathy of trauma shock (ACoTS) or yet other entities. This study investigated...... activation and had an arterial cannula inserted. Blood was sampled a median of 68 min (IQR 48-88) post-injury. Data on demography, biochemistry, injury severity score (ISS) and mortality were recorded. Plasma/serum was analyzed for biomarkers reflecting tissue/endothelial cell/glycocalyx damage (histone......-complexed DNA fragments, Annexin V, thrombomodulin, syndecan-1), coagulation activation/inhibition (prothrombinfragment 1+2, thrombin/antithrombin-complexes, antithrombin, protein C, activated protein C, endothelial protein C receptor, protein S, tissue factor pathway inhibitor, vWF), factor consumption...

  7. Modelling Coagulation Systems: A Stochastic Approach

    CERN Document Server

    Ryazanov, V V

    2011-01-01

    A general stochastic approach to the description of coagulating aerosol system is developed. As the object of description one can consider arbitrary mesoscopic values (number of aerosol clusters, their size etc). The birth-and-death formalism for a number of clusters can be regarded as a partial case of the generalized storage model. An application of the storage model to the number of monomers in a cluster is discussed.

  8. Rennet coagulation of heated milk concentrates

    OpenAIRE

    Schreiber, Regina; Hinrichs, Jörg

    2000-01-01

    International audience; The high temperature heating of cheese milk is a useful tool for preventing late fermentation during cheese ripening if the renneting properties remain unchanged. The aim of the investigations was to find heating conditions which guarantee the inactivation of clostridia spores but still enable rennet coagulation of the heated milk and milk concentrates respectively. The gel strength of the rennet gels increased the more the casein content increased. The native whey pro...

  9. [Disseminated intravascular coagulation in solid tumours].

    Science.gov (United States)

    Ferrand, François Régis; Garcia-Hejl, Carine; Moussaid, Yassine; Schernberg, Antoine; Bidard, François-Clément; Pavic, Michel; Khenifer, Safia; Stoclin, Annabelle

    2014-06-01

    Disseminated intravascular coagulation (DIC) is a complex abnormality of hemostasis with dramatic consequences and long described as associated with tumors. Yet the diagnosis and management of paraneoplastic DIC are poorly defined. The purpose of this paper is to review DIC associated with solid tumors, at the pathophysiological and therapeutic levels in particular. We also report data from a recent retrospective series of patients with DIC in the context of a solid tumor, to illustrate the epidemiological, clinical and prognostic.

  10. Electrocoagulation versus chemical coagulation: coagulation/flocculation mechanisms and resulting floc characteristics.

    Science.gov (United States)

    Harif, Tali; Khai, Moti; Adin, Avner

    2012-06-15

    Electrocoagulation (EC) and chemical coagulation (CC) are employed in water treatment for particle removal. Although both are used for similar purposes, they differ in their dosing method - in EC the coagulant is added by electrolytic oxidation of an appropriate anode material, while in CC dissolution of a chemical coagulant is used. These different methods in fact induce different chemical environments, which should impact coagulation/flocculation mechanisms and subsequent floc formation. Hence, the process implications when choosing which to apply should be significant. This study elucidates differences in coagulation/flocculation mechanisms in EC versus CC and their subsequent effect on floc growth kinetics and structural evolution. A buffered kaolin suspension served as a representative solution that underwent EC and CC by applying aluminum via additive dosing regime in batch mode. In EC an aluminum anode generated the active species while in CC, commercial alum was used. Aluminum equivalent doses were applied, at initial pH values of 5, 6.5 and 8, while samples were taken over pre-determined time intervals, and analyzed for pH, particle size distribution, ζ potential, and structural properties. EC generated fragile flocs, compared to CC, over a wider pH range, at a substantially higher growth rate, that were prone to restructuring and compaction. The results suggest that the flocculation mechanism governing EC in sweep floc conditions is of Diffusion Limited Cluster Aggregation (DCLA) nature, versus a Reaction Limited Cluster Aggregation (RLCA) type in CC. The implications of these differences are discussed.

  11. Disseminated intravascular coagulation: testing and diagnosis.

    Science.gov (United States)

    Wada, Hideo; Matsumoto, Takeshi; Yamashita, Yoshiki; Hatada, Tsuyoshi

    2014-09-25

    Abnormalities of the hemostatic system in patients with DIC result from the sum of vectors for hypercoagulation and hyperfibrinolysis. DIC is classified into hyperfibrinolysis, hypercoagulation, massive bleeding or nonsymptomatic types according to the balance of the two vectors. Both the antithrombin (AT) and protein C (PC) levels are significantly low in patients with septic DIC, and reduced amounts of AT and PC result in the lack of inhibition of thrombin and activated FVIII, respectively. Thrombin activates FVIII, while activated FVIII accelerates the coagulation pathway to generate thrombin; thus activation of the coagulation system persists. Three sets of diagnostic criteria have been established by the Japanese Ministry of Health, Labour and Welfare, International Society of Thrombosis and Haemostasis and Japanese Association for Acute Medicine, respectively. Although these three diagnostic criteria score hemostatic abnormalities using similar global coagulation tests, the sensitivity and/or specificity for death differ. Treatment with AT or activated PC may not improve the outcomes of patients with sepsis at the early stage, although they may improve the outcomes in those with DIC. Therefore, new diagnostic criteria for determining the appropriate time to initiate anticoagulant treatment are required.

  12. Dependence of LTX plasma performance on surface conditions as determined by in situ analysis of plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Lucia, M., E-mail: mlucia@pppl.gov [Princeton Plasma Physics Laboratory (PPPL), Princeton, NJ 08543 (United States); Kaita, R.; Majeski, R. [Princeton Plasma Physics Laboratory (PPPL), Princeton, NJ 08543 (United States); Bedoya, F.; Allain, J.P. [University of Illinois at Urbana-Champaign (UIUC), Urbana, IL 61801 (United States); Abrams, T.; Bell, R.E.; Boyle, D.P.; Jaworski, M.A.; Schmitt, J.C. [Princeton Plasma Physics Laboratory (PPPL), Princeton, NJ 08543 (United States)

    2015-08-15

    The Materials Analysis and Particle Probe (MAPP) diagnostic has been implemented on the Lithium Tokamak Experiment (LTX) at PPPL, providing the first in situ X-ray photoelectron spectroscopy (XPS) surface characterization of tokamak plasma facing components (PFCs). MAPP samples were exposed to argon glow discharge conditioning (GDC), lithium evaporations, and hydrogen tokamak discharges inside LTX. Samples were analyzed with XPS, and alterations to surface conditions were correlated against observed LTX plasma performance changes. Argon GDC caused the accumulation of nm-scale metal oxide layers on the PFC surface, which appeared to bury surface carbon and oxygen contamination and thus improve plasma performance. Lithium evaporation led to the rapid formation of a lithium oxide (Li{sub 2}O) surface; plasma performance was strongly improved for sufficiently thick evaporative coatings. Results indicate that a 5 h argon GDC or a 50 nm evaporative lithium coating will both significantly improve LTX plasma performance.

  13. Communication: Trapping a proton in argon: Spectroscopy and theory of the proton-bound argon dimer and its solvation

    Science.gov (United States)

    McDonald, D. C.; Mauney, D. T.; Leicht, D.; Marks, J. H.; Tan, J. A.; Kuo, J.-L.; Duncan, M. A.

    2016-12-01

    Ion-molecule complexes of the form H+Arn are produced in pulsed-discharge supersonic expansions containing hydrogen and argon. These ions are analyzed and mass-selected in a reflectron spectrometer and studied with infrared laser photodissociation spectroscopy. Infrared spectra for the n = 3-7 complexes are characterized by a series of strong bands in the 900-2200 cm-1 region. Computational studies at the MP2/aug-cc-pVTZ level examine the structures, binding energies, and infrared spectra for these systems. The core ion responsible for the infrared bands is the proton-bound argon dimer, Ar-H+-Ar, which is progressively solvated by the excess argon. Anharmonic vibrational theory is able to reproduce the vibrational structure, identifying it as arising from the asymmetric proton stretch in combination with multiple quanta of the symmetric argon stretch. Successive addition of argon shifts the proton vibration to lower frequencies, as the charge is delocalized over more ligands. The Ar-H+-Ar core ion has a first solvation sphere of five argons.