WorldWideScience

Sample records for argon plasma coagulation

  1. Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator

    International Nuclear Information System (INIS)

    Background. Distal migration is one of the common complications after insertion of a covered metallic stent. Stent repositioning or removal is not always possible in every patient. Therefore, trimming using an argon plasma coagulator (APC) may be a good alternative method to solve this problem. Methods. Metallic stent trimming by APC was performed in 2 patients with biliary Wallstent migration and in another patient with esophageal Ultraflex stent migration. The power setting was 60-100 watts with an argon flow of 0.8 l/min. Observations. The procedure was successfully performed and all distal parts of the stents were removed. No significant collateral damage to the nearby mucosa was observed. Conclusions. In a patient with a distally migrated metallic stent, trimming of the stent is possible by means of an APC. This new method may be applicable to other sites of metallic stent migration

  2. Argon plasma coagulation for treatment of hemorrhagic radiation gastroduodenitis

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Shu-Ji; Aoyama, Nobuo; Shirasaka, Daisuke; Inoue, Takashi; Kuroda, Kohei; Ebara, Shigeyuki; Tamura, Takao; Miyamoto, Masaki; Kasuga, Masato [Kobe Univ. (Japan). Graduate School of Medicine

    2002-01-01

    A 79-year-old man who had received radiotherapy for portal vein thrombosis due to hepatocellular carcinoma (HCC) 5 months earlier, showed progressive anemia and melena. Endoscopy on admission revealed diffuse bleeding from multiple telangiectasias on the anterior wall of the antrum and bulbus. We treated this patient with a new non-contact hemostatic method: the argon plasma coagulator (APC). The melena stopped after the first session and the hemoglobin level remained stable for 7 months. No delayed complications have been observed. Gastrointestinal bleeding from chronic radiation gastroduodenitis is rarely reported compared with radiation proctitis. This case demonstrates that APC is effective for hemostasis of diffuse bleeding from radiation gastroduodenitis, just as for radiation protitis. (author)

  3. Ablation of Barrett’s esophagus using the second-generation argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To investigate the efficacy and safety of the second-generation argon plasma coagulation (VIO APC) in ablation of Barrett’s esophagus. Methods Eighteen patients with Barrett’s esophagus (12 males, median age of 55 years, median length of 2.1 cm,1 low-grade dysplasia, 13 cases of short segment Barrett’s esophagus) received VIO APC, which was performed at a power setting of 40W and argon gas flow at 1.5-2.0 L/min, "forced" mode, in 1-3 sessions (mean 1.3). All the patients received treatment with hi...

  4. Bronchial asthma control after argon plasma coagulation turbinectomy in patients with chronic rhinitis

    OpenAIRE

    Jura-Szołtys, Edyta; Ficek, Rafał; Ficek, Joanna; Markowski, Jarosław; Chudek, Jerzy

    2013-01-01

    Bronchial asthma is frequently accompanied by chronic rhinitis. It has been observed that effective treatment of rhinitis may reduce asthma symptoms. The aim of the study was the evaluation of the control of bronchial asthma symptoms in patients with chronic rhinitis after argon plasma coagulation turbinectomy (APCt). The effect of APCt was assessed in 47 adults with drug-resistant chronic rhinitis and bronchial asthma 3-month post-procedure. Changes of asthma symptoms were scored using Asthm...

  5. Epinephrine plus argon plasma or heater probe coagulation in ulcer bleeding

    Institute of Scientific and Technical Information of China (English)

    Ahmet Karaman; Mevlut Baskol; Sebnem Gursoy; Edip Torun; Alper Yurci; Banu Demet Ozel; Kadri Guven; Omer Ozbakir; Mehmet Yucesoy

    2011-01-01

    AIM: To compare the effectiveness of argon plasma coagulation (APC) and heater probe coagulation (HPC) in non-variceal upper gastrointestinal bleeding. METHODS: Eighty-five (18 female, 67 male) patients admitted for acute gastrointestinal bleeding due to gastric or duodenal ulcer were included in the study. Upper endoscopy was performed and HPC or APC were chosen randomly to stop the bleeding. Initial hemostasis and rebleeding rates were primary and secondary end-points of the study. RESULTS: Initial hemostasis was achieved in 97.7% (42/43) and 81% (36/42) of the APC and HPC groups, respectively (P 0.05). CONCLUSION: APC is an effective hemostatic method in bleeding peptic ulcers. Larger multicenter trials are necessary to confirm these results.

  6. Argon Plasma Coagulation Combined with Covered Stent Placement for Management of Tracheobronchial Stenoses/occlusions as well as Esophagorespiratory Fistulas

    OpenAIRE

    Hongwu WANG; Lingfei LUO; Yunzhi ZHOU; Ma, Hongming; Li, Jing; Zou, Heng; Li, Dongmei; Zhang, Nan

    2010-01-01

    Background and objective It is a complex problem and difficult treatment for tracheobronchial stenoses/occlusions involving in carina. The aim of this study is to investigate the feasibility and efficiency of argon plasma coagulation (APC) and bifurcated covered Z-type stents (CZTS) placement for the treatment of tracheobronchus stenoses and esophagorespiratory fistula (ERF). Methods Thirty-two cases with airway disorders were retrospectively reviewed for the treatment of APC and CZTS placeme...

  7. Long-term follow-up after complete ablation of Barrett's esophagus with argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    Ahmed Madisch; Stephan Miehlke; Ekkehard Bayerd(o)rffer; Birgit Wiedemann; David Antos; Anke Sievert; Michael Vieth; Manfred Stolte; Heinrich Schulz

    2005-01-01

    AIM: To report the long-term outcome of patients after complete ablation of non-neoplastic Barrett's esophagus (BE) with respect to BE relapse and development of intraepithelial neoplasia or esophageal adenocarcinoma.METHODS: In 70 patients with histologically proven nonneoplastic BE, complete BE ablation was achieved by argon plasma coagulation (APC) and high-dose proton pump inhibitor therapy (120 mg omeprazole daily). Sixty-six patients (94.4%) underwent further surveillance endoscopy. At each surveillance endoscopy four-quadrant biopsies were taken from the neo-squamous epithelium at 2 cm intervals depending on the pre-treatment length of BE mucosa beginning at the neo-Z-line, and from any endoscopically suspicious lesion.RESULTS: The median follow-up of 66 patients was 51 mo (range 9-85 mo) giving a total of 280.5 patient years.A mean of 6 biopsies were taken during surveillance endoscopies. In 13 patients (19.7%) tongues or islands suspicious for BE were found during endoscopy. In 8 of these patients (12.1%) non-neoplastic BE relapse was confirmed histologically giving a histological relapse rate of 3% per year. In none of the patients, intraepithelial neoplasia nor an esophageal adenocarcinoma was detected.Logistic regression analysis identified endoscopic detection of islands or tongues as the only positive predictor of BE relapse (P = 0.0004).CONCLUSION: The long-term relapse rate of nonneoplastic BE following complete ablation with high-power APC is low (3% per year).

  8. Endoscopic ablation of Barrett's esophagus using high power setting argon plasma coagulation: A prospective study

    Institute of Scientific and Technical Information of China (English)

    Corrado Pedrazzani; Filippo Catalano; Mara Festini; Germana Zerman; Anna Tomezzoli; Andrea Ruzzenente; Alfredo Guglielmi; Giovanni de Manzoni

    2005-01-01

    AIM: This prospective study evaluated the effectiveness of 90 W argon plasma coagulation (APC) for the ablation of Barrett's esophagus (BE) that is considered to be the main risk factor for the development of esophageal adenocarcinoma.METHODS: The results from 25 patients, observed at the First Department of General Surgery, University of Verona, Italy, from October 2000 to October 2003, who underwent APC for histologically proven BE were prospectively analyzed.RESULTS: The ablation treatment was completed in all the patients but one (96%). The mean number of APC sessions needed to complete ablation was 1.6 (total number: 40). The eradication was obtained in the majority of cases by one session only (60%), two sessions were required in 24% of the cases and three or more in 16%.About 43% of the sessions were complicated. Retrosternal pain (22.5%) and fever (17.5%) were the most frequent symptoms. Only one major complication occurred, it was an hemorrhage due to ulcer formation on the treated esophagus that required urgent endoscopic sclerosis and admission. The follow-up was accomplished in all the patients with a mean period of 26.3 mo and 20 patients (84%) with a follow-up period longer than 24 mo. Only one patient showed a relapse of metaplastic mucosa 12 mo after the completion of ablation. The patient was hence re-treated and now is free from recurrence 33 mo later.CONCLUSION: High power setting (90 W) APC showed to be safe and effective. The effects persist at a mean follow-up period of two years with a comparable cost in term of complications with respect to standard power settings. Further studies with greater number of patients are required to confirm these results and to assess if ablation reduces the incidence of malignant progression.

  9. Argon plasma coagulation for superficial esophageal squamous-cell carcinoma in high-risk patients

    Institute of Scientific and Technical Information of China (English)

    Kumiko Tahara; Satoshi Tanabe; Kenji Ishido; Katsuhiko Higuchi; Tohru Sasaki; Chikatoshi Katada; Mizutomo Azuma

    2012-01-01

    AIM:To evaluate the usefulness and safety of argon plasma coagulation (APC) for superficial esophageal squamous-cell carcinoma (SESC) in high-risk patients.METHODS:We studied 17 patients (15 men and 2 women,21 lesions) with SESC in whom endoscopic mucosal resection (EMR),endoscopic submucosal dissection (ESD),and open surgery were contraindicated from March 1999 through February 2009.None of the patients could tolerate prolonged EMR/ESD or open surgery because of severe concomitant disease (e.g.,liver cirrhosis,cerebral infarction,or ischemic heart disease) or scar formation after EMR/ESD and chemoradiotherapy.After conventional endoscopy,an iodine stain was sprayed on the esophageal mucosa to determine the lesion margins.The lesion was then ablated by APC.We retrospectively studied the treatment time,number of APC sessions per site,complications,presence or absence of recurrence,and time to recurrence.RESULTS:The median duration of follow-up was 36 mo (range:6-120 mo).All of the tumors were macroscopically classified as superficial and slightly depressed type (0-Ⅱ c).The preoperative depth of invasion was clinical T1a (mucosal cancer) for 19 lesions and clinical T1b (submucosal cancer) for 2.The median treatment time was 15 min (range:10-36 min).The median number of treatment sessions per site was 2 (range:1-4).The median hospital stay was 14 d (range:5-68d).Among the 17 patients (21 lesions),2 (9.5%) had recurrence and underwent additional APC with no subsequent evidence of recurrence.There were no treatment-related complications,such as bleeding or perforation.CONCLUSION:APC is considered to be safe and effective for the management of SESC that cannot be resected endoscopically because of underlying disease,as well as for the control of recurrence after EMR and local recurrence after chemoradiotherapy.

  10. Efficacy of argon plasma coagulation in the management of portal hypertensive gastropathy

    Science.gov (United States)

    Hanafy, Amr Shaaban; El Hawary, Amr Talaat

    2016-01-01

    Objectives: Evaluation of the outcome and experience in 2 years of management of portal hypertensive gastropathy (PHG) by argon plasma coagulation (APC) in a cohort of Egyptian cirrhotic patients. Methods: This study was conducted over a 2-year period from January 2011 to February 2013. Upper gastrointestinal endoscopy was performed to evaluate the degree and site of PHG. APC was applied to areas with mucosal vascular lesions. Results: In total, 200 cirrhotic patients were enrolled; 12 patients were excluded due to death (n = 6) caused by hepatic encephalopathy (n = 3), hepatorenal syndrome (n = 2), or chronic lymphatic leukemia (n = 1), or did not complete the treatment sessions (n = 6), so 188 patients completed the study. PHG was mainly fundic in 73 patients (38.8 %), corporeal in 66 patients (35.1 %), and pangastric in 49 patients (26.1 %) (P = 0.026). Patients were exposed to APC and received proton pump inhibitors together with propranolol at a dose sufficient to reduce the heart rate by 25 % or down to 55 beats/min. The mean (± standard deviation) number of sessions was 1.65 ± 0.8; six patients needed four sessions (3.2 %), 19 patients needed three sessions (10.1 %), 74 patients needed two sessions (39.4 %), and 89 patients needed one session (47.3 %). Patients with fundic and corporeal PHG required the lowest number of sessions (P = 0.000). Patients were followed up every 2 months for up to 1 year; the end point was a complete response with improved anemia and blood transfusion requirement which was achieved after one session in 89 patients (75.4 %), two sessions in 24 patients (20.3 %) and three sessions in five patients (4.3 %). A complete response was more prevalent in patients with corporeal and fundic PHG (P = 0.04). Conclusions: After 2 years’ experience in managing PHG, we found that a combination of APC and non-selective beta blockers was highly efficacious and safe in controlling

  11. Argon Plasma Coagulation Therapy Versus Topical Formalin for Intractable Rectal Bleeding and Anorectal Dysfunction After Radiation Therapy for Prostate Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yeoh, Eric, E-mail: eric.yeoh@health.sa.gov.au [Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide (Australia); School of Medicine, University of Adelaide, Adelaide (Australia); Tam, William; Schoeman, Mark [School of Medicine, University of Adelaide, Adelaide (Australia); Department of Gastroenterology, Royal Adelaide Hospital, Adelaide (Australia); Moore, James; Thomas, Michelle [School of Medicine, University of Adelaide, Adelaide (Australia); Department of Colorectal Surgery, Royal Adelaide Hospital, Adelaide (Australia); Botten, Rochelle; Di Matteo, Addolorata [Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide (Australia)

    2013-12-01

    Purpose: To evaluate and compare the effect of argon plasma coagulation (APC) and topical formalin for intractable rectal bleeding and anorectal dysfunction associated with chronic radiation proctitis. Methods and Materials: Thirty men (median age, 72 years; range, 49-87 years) with intractable rectal bleeding (defined as ≥1× per week and/or requiring blood transfusions) after radiation therapy for prostate carcinoma were randomized to treatment with APC (n=17) or topical formalin (n=13). Each patient underwent evaluations of (1) anorectal symptoms (validated questionnaires, including modified Late Effects in Normal Tissues–Subjective, Objective, Management, and Analytic and visual analogue scales for rectal bleeding); (2) anorectal motor and sensory function (manometry and graded rectal balloon distension); and (3) anal sphincteric morphology (endoanal ultrasound) before and after the treatment endpoint (defined as reduction in rectal bleeding to 1× per month or better, reduction in visual analogue scales to ≤25 mm, and no longer needing blood transfusions). Results: The treatment endpoint was achieved in 94% of the APC group and 100% of the topical formalin group after a median (range) of 2 (1-5) sessions of either treatment. After a follow-up duration of 111 (29-170) months, only 1 patient in each group needed further treatment. Reductions in rectal compliance and volumes of sensory perception occurred after APC, but no effect on anorectal symptoms other than rectal bleeding was observed. There were no differences between APC and topical formalin for anorectal symptoms and function, nor for anal sphincteric morphology. Conclusions: Argon plasma coagulation and topical formalin had comparable efficacy in the durable control of rectal bleeding associated with chronic radiation proctitis but had no beneficial effect on anorectal dysfunction.

  12. The role of argon plasma coagulation in the management of Barrett's esophagus: a single-center experience

    Directory of Open Access Journals (Sweden)

    Gad YZ

    2011-04-01

    Full Text Available Yahia Z Gad1, Adel A Zeid21Associate Professor of Internal Medicine, Mansoura Specialized Medical Hospital, Mansoura University, Mansoura, Egypt; 2Consultant Surgeon, Al Nil Hospital, Mansaura, EgyptBackground/aim: Patients with Barrett's esophagus (BE are 30 times more likely to develop esophageal adenocarcinoma (EAC than the general population. Data regarding the use of argon plasma coagulation (APC for treatment of patients with BE in Egypt are still limited. This article discusses the efficacy and safety of APC as a thermoablative modality in Egyptian patients with BE.Materials and methods: A total of 73 referred eligible patients with a confirmed endoscopic and histopathologic diagnosis of BE were enrolled in this study and subjected to thermoablation by high-power (hp-APC equipment at a 60 W setting until complete ablation or a maximum of five sessions and were followed up clinically and endoscopically at 3-month intervals. Computer-generated randomization allocated patients into APC-treated and control groups (n = 75, all of whom were treated with a proton pump inhibitor.Results: Minor and major complications occurred in 8 of 73 (10.95% and 1 of 73 (1.36% patients, respectively. Macroscopic ablation was achieved after one session in 37 of 73 (50.63% patients, and complete histologic ablation was confirmed after 167 sessions in 69 of 73 (94.52% patients. At 1-year follow-up, no relapses of BE or progression to EAC were observed.Conclusion: hp-APC at a medium-energy setting of 60 W in an acid-reduced environment can ablate BE effectively and safely with promising initial results.Keywords: Barrett's esophagus, argon plasma coagulation

  13. Argon Plasma Coagulation Combined with Covered Stent Placement for Management of Tracheobronchial Stenoses/occlusions as well as Esophagorespiratory Fistulas

    Directory of Open Access Journals (Sweden)

    Hongwu WANG

    2010-09-01

    Full Text Available Background and objective It is a complex problem and difficult treatment for tracheobronchial stenoses/occlusions involving in carina. The aim of this study is to investigate the feasibility and efficiency of argon plasma coagulation (APC and bifurcated covered Z-type stents (CZTS placement for the treatment of tracheobronchus stenoses and esophagorespiratory fistula (ERF. Methods Thirty-two cases with airway disorders were retrospectively reviewed for the treatment of APC and CZTS placement. Under the bronchoscopic guidance, APC was first given in patients with airway stenoses, then CZTS was placed under the fluoroscopic and flexible bronchoscopic guidance either with airway stenoses or ERF. Results APC was first given in 19 patients with airway stenoses. Airway structures were significantly improved after APC procedure (57.4%-72.1% before APC vs 12.8%-25.8% after APC. Thirty-two CZTS were technically successfully placed in 30 out of 32 cases involving in carinal bifurcation. After APC and stent placement, short breath index was significantly reduced and karnofsky physical score (KPS increased obviously. The endobronchial defects were successfully palliated with bifurcated CZTS placed under fluoroscopy and flexible bronchoscopy in 12 out of 13 patients with ERFs. There is no bleeding introprocedure. Mucous retention was very common in all types of the stents less than 2 weeks after stenting, which required debridement by bronchoscopy and could be prevented by normal saline solution nebulizations. Granuloma developed at the ends of stents after 1 month of stenting which all of them were treated successfully with APC and CO2 cryosurgery. Conclusion Utilization of APC and retrieval bifurcated CZTS placement is a simple and safe protocol for the management of airway complex stenoses involving the tracheal carina and ERF.

  14. Comparison of Hemostatic Efficacy of Argon Plasma Coagulation with and without Distilled Water Injection in Treating High-Risk Bleeding Ulcers

    Directory of Open Access Journals (Sweden)

    Yuan-Rung Li

    2014-01-01

    Full Text Available Background. Argon plasma coagulation (APC is useful to treat upper gastrointestinal bleeding, but its hemostatic efficacy has received little attention. Aims. This investigation attempted to determine whether additional endoscopic injection before APC could improve hemostatic efficacy in treating high-risk bleeding ulcers. Methods. From January 2007 to April 2011, adult patients with high-risk bleeding ulcers were included. This investigation compared APC plus distilled water injection (combined group to APC alone for treating high-risk bleeding ulcers. Outcomes were assessed based on initial hemostasis, surgery, blood transfusion, hospital stay, rebleeding, and mortality at 30 days posttreatment. Results. Totally 120 selected patients were analyzed. Initial hemostasis was accomplished in 59 patients treated with combined therapy and 57 patients treated with APC alone. No significant differences were noted between these groups in recurred bleeding, emergency surgery, 30-day mortality, hospital stay, or transfusion requirements. Comparing the combined end point of mortality plus the failure of initial hemostasis, rebleeding, and the need for surgery revealed an advantage for the combined group (P=0.040. Conclusions. Endoscopic therapy with APC plus distilled water injection was no more effective than APC alone in treating high-risk bleeding ulcers, whereas combined therapy was potentially superior for patients with poor overall outcomes.

  15. Watermelon stomach: clinical aspects and treatment with argon plasma coagulation Ectasia vascular do antro gástrico ("watermelon stomach": aspectos clínicos e tratamento com coagulação com plasma de argônio

    Directory of Open Access Journals (Sweden)

    Dalton M. Chaves

    2006-09-01

    Full Text Available BACKGROUND: Gastric antral vascular ectasia is a disorder whose pathogenetic mechanism is unknown. The endoscopic treatment with argon plasma coagulation has been considered one of the best endoscopic therapeutic options. AIM: To analyze the endoscopic and clinical features of gastric antral vascular ectasia and its response to the argon plasma coagulation treatment. PATIENTS AND METHODS: Eighteen patients were studied and classified into two groups: group 1 - whose endoscopic aspect was striped (watermelon or of the diffuse confluent type; group 2 - diffuse spotty nonconfluent endoscopic aspect. RESULTS: Group 1 with eight patients, all having autoimmune antibodies, but one, whose antibodies were not searched for. Three were cirrhotic and three had hypothyroidism. All had gastric mucosa atrophy. In group 2, with 10 patients, all had non-immune liver disease, with platelet levels below 90.000. Ten patients were submitted to argon plasma coagulation treatment, with 2 to 36 months of follow-up. Lesions recurred in all patients who remained in the follow-up program and one did not respond to treatment for acute bleeding control. CONCLUSION: There seem to be two distinct groups of patients with gastric antral vascular ectasia: one related to immunologic disorders and other to non-immune chronic liver disease and low platelets. The endoscopic treatment using argon plasma coagulation had a high recurrence in the long-term evaluation.RACIONAL: "Watermelon stomach" ou ectasia vascular do antro gástrico é uma doença de etiopatogenia desconhecida. O tratamento endoscópico através da coagulação com plasma de argônio é considerado uma das melhores opções terapêuticas. OBJETIVO: Analisar os aspectos clínicos e endoscópicos da ectasia vascular do antro gástrico e a resposta ao tratamento com coagulação com plasma de argônio. PACIENTES E MÉTODOS: Dezoito pacientes foram estudados e classificados em dois grupos: grupo I - oito pacientes que

  16. 内镜下HFEC术对比APC术治疗大肠息肉的疗效探究%Clinical efficacy of endoscopic high frequency electric coagulation and argon plasma coagulation for colorectal polyps

    Institute of Scientific and Technical Information of China (English)

    刘伟

    2015-01-01

    目的 探究内镜下高频电凝切除术(High frequency electric coagulation,HFEC)与氩离子凝固术(Argon plasma coagulation,APC)在大肠息肉(Colorectal polyps,CP)治疗中的价值,为临床上CP治疗方式的选择提供依据.方法选择2009年3月-2014年3月在杭州师范大学附属医院接受治疗的CP患者980例,随机分成HFEC组490例(息肉653枚)和APC组490例(息肉688枚),HFEC组患者采用HFEC切除治疗,APC组则采用APC术治疗.治疗后,统计2组患者一次清除率和并发症发生率,据此评价两种术式对CP治疗的价值.结果采用SPSS19.0进行统计学分析,行x2检验,以P<0.05为差异具有统计学意义.结果 APC组一次切除息肉635枚,两次及以上切除53枚,一次切除率为92.3%,而HFEC组一次切除息肉562枚,两次及以上切除91枚,一次切除率为86.1%,2组一次切除率比较,差异具有统计学意义(x2 =13.58,P<0.05);APC组发生腹胀22例,腹痛13例,穿孔1例,出血2例,并发症率为7.8%;HFEC组发生腹胀34例,腹痛21例,穿孔6例,出血9例,并发症率为14.3%,2组并发症率比较,差异具有统计学意义(x2=10.66,P<0.05).结论 APC术治疗CP一次切除率高,且并发症低,安全可靠,是CP患者较佳的治疗方式.

  17. Safety and efficacy of argon plasma coagulator ablation therapy for flat colorectal adenomas Seguridad y eficacia de la ablación de pólipos colorrectales con argón plasma

    Directory of Open Access Journals (Sweden)

    A. García

    2004-05-01

    Full Text Available Introduction: argon-plasma coagulation (APC has been used safely and efficaciously in multiple settings including colon polyp treatment. The aim of this study was to evaluate APC efficacy and safety in the treatment of flat colorectal adenomas. Materials and methods: APC ablation was prospectively performed and evaluated in 22 consecutive patients with colorectal adenomas, 11 of which had large sessile adenomas that were treated with piecemeal polypectomy and APC ablation of residual adenomatous tissue, whereas the remaining eleven patients with flat or carpet-like adenomas were only treated with APC. The mean initial longitudinal extension of adenomas to be treated with APC was 22 mm (range, 20 to 40 mm. Results: the mean age of patients was 70 years. Adenomas were found most frequently in the rectum (50% and cecum (23%. Complete ablation was achieved in 90.9% of adenomas. Recurrence was observed in 20% of patients, all of them in the rectum, after a mean follow-up period of 16.3 months (range, 8 to 35. All recurrences were managed satisfactorily. No major complications were seen. Conclusions: argon plasma coagulator ablation of flat colorectal adenomas is an efficacious and safe technique, specially in the right colon, but results must be confirmed in controlled trials with a higher number of patients.Introducción: el argón plasma (AP, como terapia endoscópica, ha sido utilizado en diferentes lesiones digestivas, incluyendo la ablación de tejido adenomatoso de pólipos colorrectales. El objetivo del presente estudio fue evaluar la seguridad y efectividad del tratamiento con AP de pólipos colorrectales. Material y métodos: se valoró de forma prospectiva la aplicación en la práctica clínica de AP en el tratamiento de 22 pacientes con pólipos colorrectales, de los cuales 11 pacientes con pólipos de gran tamaño fueron tratados con polipectomía endoscópica fragmentada más ablación del tejido adenomatoso con AP, y los otros 11

  18. Argon plasma irradiation of polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Slepicka, P., E-mail: petr.slepicka@vscht.c [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic); Vasina, A. [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic); Kolska, Z. [J.E. Purkyne University, Department of Chemistry, 40096 Usti Nad Labem (Czech Republic); Luxbacher, T. [Anton Paar GmbH, 8054 Graz (Austria); Malinsky, P.; Mackova, A. [Nuclear Physics Institute of Academy of Sciences of the Czech Republic, 25068 Rez (Czech Republic); Svorcik, V. [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic)

    2010-06-15

    Polypropylene samples were exposed to argon plasma discharge and the changes of the PP surface properties were studied by different methods. Surface wettability was derived from contact angle measured by standard goniometry and chemical structure of the plasma modified PP was studied using X-ray photoelectron spectroscopy (XPS) and by Rutherford backscattering spectroscopy (RBS), surface morphology and roughness of samples using AFM. Zeta potential of pristine and modified PP was determined with the SurPASS. The presence of incorporated oxygen in the PP surface layer, about 60 nm thick, was observed in RBS spectra. Oxygen concentration is a decreasing function of the depth. With progressing aging time the oxygen concentration on the PP surface decreases. Plasma treatment results in a rapid decrease of the contact angle, which increases again with increasing aging time. In XPS measurement the oxygen containing structures, created by the plasma treatment, were found on the very surface of the modified PP and the zeta potential being changed too. The significant difference in zeta potential between pristine and plasma treated PP clearly indicates that the plasma treatment leads to a more hydrophilic PP surface.

  19. 内镜下氩离子凝固术治疗老年人大肠息肉%Endoscopic argon plasma coagulation in the treatment of elderly patients with colorectal polyps

    Institute of Scientific and Technical Information of China (English)

    邵耘; 何晓璞; 吴爱娟; 陈国胜; 许海尘; 薛绮萍; 孙为豪

    2012-01-01

    目的 探讨内镜下氩离子凝固术(APC)治疗老年人大肠息肉的安全性和有效性.方法 采用德国ERBE 公司生产的APC(VI0 200D型)内镜专用氩气刀对电子肠镜检查发现的大肠息肉进行内镜下治疗.结果 258例老年患者共检出525枚息肉全部使用APC治愈,根据息肉大小和形态,使用APC灼除302枚(57.5%),APC切除89枚(17%),黏膜下注射后APC切除134枚(25.5%),局部渗血者行APC电凝或钛夹止血.术后2例(0.8%)出现少量便血,予药物治疗后出血停止,无穿孔和大出血等严重并发症.结论 APC可作为老年人大肠息肉的首选治疗,安全性高,并发症少.%Objective To evaluate the safety and efficacy of endoscopic argon plasma coagulation (APC) in the treatment of elderly patients with colorectal polyps. Methods Colorectal polyps found in electronic enteroscopy were treated with argon plasma generated by ERBE APC (VIO 200D, ERBE Company, German) . Results A total of 525 polyps were detected in 258 elderly patients and all were cured by APC. According to the polyp size and morphology, 302 (57.5%) sessile flat polyps with diameter 0.2 cm to 0.5 cm were ablated with APC, 89 (17%) semi-pedunculated and pedunculated polyps were resected by high-frequency electrosection, and 134 sessile (25.5%) polyps with diameter 0.6 cm to 5.0 cm were resected after submucosal injection with epinephrine plus methylene blue normal saline on focal membrane. APC electric coagulation or titanium clip was employed when bleeding appeared in partial wounds. Minor bleeding occurred in two patients (0.8%) and was stopped after treated with hemostatic drugs; there were no serious complications such as perforations or bleeding requiring transfusion. Conclusion APC is a well tolerated and effective treatment for elderly patients with colorectal polyps.

  20. A clinical study on treating Barrett’s esophagus with argon plasma coagulation plus esomeprazole%氩离子凝固术配合埃索美拉唑治疗 Barrett 食管临床研究

    Institute of Scientific and Technical Information of China (English)

    钱鑫

    2014-01-01

    目的:探讨内镜下氩离子凝固术(Argon Plasma Coagulation,APC)配合抑酸治疗Barrett食管(Barrett’s Esophagus, BE)的临床疗效。方法:在内镜下以APC对40例经病理证实为肠上皮化生的BE完全损毁化生黏膜,再配合埃索美拉唑抑酸治疗,术后再进行内镜、病理随访12个月。结果:40例均完成治疗,其中需要1次治疗者28例,2次治疗者11例,3次治疗者1例。37例达到完全的鳞状上皮再生(92.5%),3例再生的鳞状上皮间混有岛状的柱状上皮(7.5%),12个月后共有4例出现内镜下可见的复发。结论:内镜下APC配合抑酸治疗BE安全、有效,但有一定比例的复发和残留。%Objective: To study clinical effects of the argon plasma coagulation (APC) plus esomeprazole on Barrett’s esophagus(BE). Methods: 40 patients with Barrett’s esophagus confirmed by endoscope were treated with APC and successively acid suppression therapy. All the patients were rechecked by endoscope and pathology method on 12 months after treatment. Results: All patients were accomplished treatment. The eradication was obtained in 28 cases by only one session and 11 cases two session, 1 cases three sessions. The complete squamous reepithelialization was observed in 37 patients (92.5%), and remnant islands of columnar epithelium mixed with squamous reepithelialization in the original places were observed in 3 patients (7.5%). The reappearance of columnar epithelium was observed in 4 patients in 12 months. Conclusion: APC plus esomeprazole in Barrett’s esophagus’ endepidermis show obvious reversal function, however, recurrences and residual of BE are present in minority of patients.

  1. 氩离子凝固术治疗结直肠息肉的临床应用价值%Application value of curing colorectal polyps with the argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    张兰霞; 张鸣青; 王爱民

    2012-01-01

    Objective To evaluate the efficacy and the clinical value of argon plasma coagulation ( APC) in the treatment of colorectal polyps. Methods One hundred and sixty patients with 351 colorectal polyps were treated with APC ablation. 214 sessile and 65 semi-pedunculated polyps were only treated with APC, 72 pedunculated polyps were treated with polypectomy and polyp remnants were also treated with APC. Results All of the patients were healed. Symptomless emphysema under the local mucosal occurred in 2 patients. Transient mild abdominal pain occurred in 78 patients and relieved without treatment. Conclusion APC is an effective and safe method for treating colorectal polyp. It is easy to operate with fewer complications and can be the preferred method for the applanate and wide outsole polyps.%目的 探讨氩离子凝固术治疗结直肠息肉的疗效及临床应用价值.方法 对160例患者共351枚结直肠息肉行氩离子凝固术(APC)治疗,其中214枚扁平和65枚亚蒂息肉仅行APC治疗,72枚有蒂息肉电切治疗后用APC处理息肉残端.结果 本组病例全部临床治愈.2例患者出现无症状的局部黏膜下气肿,78例患者出现短暂腹痛,未行处理自行缓解.结论 APC是一种安全有效的结直肠息肉治疗方法,副反应少,操作简便,尤其是在扁平、广基息肉的治疗中可作为首选方法.

  2. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  3. Efficacy of Argon Plasma Coagulation in Management of Different Pathologic Types Colorectal Polyps%氩离子凝固术治疗不同病理类型结直肠息肉的疗效观察

    Institute of Scientific and Technical Information of China (English)

    赵曙光; 王旭霞; 黄裕新; 闻勤生; 赵保民

    2008-01-01

    目的:氩离子凝固术(Argon-plasma coagulation,APC)可以有效地治疗结直肠息肉,对不同病理类型息肉的疗效是否存在差异,目前尚不清楚.本文比较APC治疗不同病理类型结直肠息肉的效果.方法:对62例结直肠息肉患者共112枚结肠息肉行APC治疗,其中17例亚蒂和74例扁平息肉仅用APC治疗;21例有蒂息肉电切治疗后用APC处理息肉残基,治疗结束后1个月进行结肠镜随访.结果:112枚结直肠息肉经一次APC治疗均成功清除,随访期间共有4例(6.5%)患者出现复发,均为直肠腺瘤性息肉,经再次APC治疗后彻底清除.单纯APC治疗组复发3枚(3.3%);电切后用APC处理残端组术后复发1枚(4.7%),两组间复发率无显著差别(P>0.05),腺瘤性息肉的复发率显著高于其他两种病理类型(P<0.05).1例直肠有蒂息肉经圈套器切除后APC处理残端时出现黏膜下气肿,3例患者出现了短暂的腹痛,未经处理缓解,其余患者无特殊并发症.结论:APC是一种安全有效的结直肠息肉治疗方法,但对腺瘤性息肉APC治疗后应加强随访,以确保治疗成功.

  4. Merging of high speed argon plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Case, A.; Messer, S.; Brockington, S.; Wu, L.; Witherspoon, F. D. [HyperV Technologies Corp., Chantilly, Virginia 22180 (United States); Elton, R. [University of Maryland, College Park, Maryland 20742 (United States)

    2013-01-15

    Formation of an imploding plasma liner for the plasma liner experiment (PLX) requires individual plasma jets to merge into a quasi-spherical shell of plasma converging on the origin. Understanding dynamics of the merging process requires knowledge of the plasma phenomena involved. We present results from the study of the merging of three plasma jets in three dimensional geometry. The experiments were performed using HyperV Technologies Corp. 1 cm Minirailguns with a preionized argon plasma armature. The vacuum chamber partially reproduces the port geometry of the PLX chamber. Diagnostics include fast imaging, spectroscopy, interferometry, fast pressure probes, B-dot probes, and high speed spatially resolved photodiodes, permitting measurements of plasma density, temperature, velocity, stagnation pressure, magnetic field, and density gradients. These experimental results are compared with simulation results from the LSP 3D hybrid PIC code.

  5. Flow Parameters of Argon plasma Discharge

    International Nuclear Information System (INIS)

    Owing to the viscosity, the plasma will be adhering to the inner surface of the outer electrode and outer surface of the inner one. As result that the discharge will be eroding the walls of coaxial system. The thickness of the boundary layer near the walls has been estimated at different positions from the breech of coaxial plasma gun. It is found that the thickness of layer 0.008 cm at the end of inner electrode (17 cm). A coaxial plasma gun device is operated in argon gas at ambient pressure 0.6 Torr and discharge voltage about 10 KV. The electron temperature of argon discharge has been determined by using spectroscopic technique. It is found that kTe=3.4 eV. By knowing the thickness of the boundary layer, the density can be determined. The Reynolds number R=105 and Mach number M=5 i.e. the flow is compressible and hypersonic

  6. Comparison of clinical efficacy between arterial infusion and embolization with arterial infusion and argon plasma coagulation in the treatment of patients with advanced central type lung cancer%支气管动脉化疗+栓塞与支气管动脉化疗联合氩等离子体治疗晚期中央型肺癌的疗效比较

    Institute of Scientific and Technical Information of China (English)

    王梅芳; 刘玉全; 唐以军; 熊畅; 卢进昌; 刘先军; 刘为舜; 雷怀定; 罗国仕

    2013-01-01

    目的 探讨应用支气管动脉化疗联合氩等离子体治疗晚期中央型肺癌的近期疗效.方法 分析比较我院45例晚期中央型肺癌分别行支气管动脉化疗+栓塞与支气管动脉化疗联合氩等离子体治疗疗效差别.结果 支气管动脉化疗联合氩等离子体治疗晚期中央型肺癌组实体瘤缓解率(87.5%)及气道狭窄再通改善率(91.7%)明显优于支气管动脉化疗+栓塞组的57.1%及52.4%,且近期生存质量好.结论 应用支气管动脉化疗联合氩等离子体治疗晚期中央型肺癌近期疗效明显优于支气管动脉化疗+栓塞治疗组,且能提高患者生活质量.%Objective To study the therapeutic effects to combine bronchial arterial chemotherapy with argon plasma coagulation on patients with advanced central type lung cancer. Methods 45 cases with central type lung cancer were collected, including one group treated by bronchial arterial chemotherapy combined with embolization and another group treated by bronchial arterial chemotherapy combined with argon plasma coagulation ( APC ). Results The solid tumor response rate and airway narrowing recanalization rate of improvement in the group treated by bronchial arterial chemotherapy combined with argon plasma coagulation were respectively 87. 5% and 91. 7% , which were significantly higher than the group treated by bronchial arterial chemotherapy combined with embolization, respectively 57. 1 % and 52. 4%. At the same time, the patients treated by bronchial arterial chemotherapy combined with argon plasma coagulation enjoyed better quality of life recently. Conclusion The clinical therapeutic effects of bronchial arterial chemotherapy combined with argon plasma coagulation on patients with advanced stage central type lung cancer is apparently superior comparing with that of bronchial arterial chemotherapy and embolization treatment group. The combined therapy of arterial infusion and APC can improve patients'life quality, thus it

  7. Development of a low-cost inductively coupled argon plasma

    International Nuclear Information System (INIS)

    The aim of this investigation is to drastically reduce running costs of an inductively coupled plasma. This is done by reducing the argon consumption from 20 l/min to about 1 l/min. First, a sample introduction system operating on 0.1 l/min of carrier argon is described. This system ensures a high ratio of plasma argon and carrier argon even at the low total argon consumptions intended. Next, the developed low consumption plasma is presented. In the proposed design, air is blown perpendicularly against the outside of the torch. A different coil has been developed to make air-cooling efficient. Preliminary data on coupling efficiency for the air-cooled plasma are presented. A similarly low argon consumption has been achieved with water as an external coolant medium. It is concluded that a cheaper alternative to the current ICP has become available. (Auth.)

  8. Nitrogen Removal from Molten Steel under Argon DC Glow Plasma

    Institute of Scientific and Technical Information of China (English)

    SUN Ming-shan; DING Wei-zhong; LU Xiong-gang

    2005-01-01

    Under argon DC glow plasma, the nitrogen removal from molten steel was studied. The experimental result showed that nitrogen mass percent could be reduced to 0.000 8%. The change of polarity had no impact on nitrogen removal when the nitrogen mass percent was low. The mechanism of denitrogenation of molten steel under argon DC glow plasma was discussed.

  9. Discussion of the nursing care of advanced esophageal cancer after treatment with Argon plasma coagulation combined 5-FU plus anhydrous alcohol%氩气刀联合5-FU加无水酒精治疗晚期食管癌患者的护理

    Institute of Scientific and Technical Information of China (English)

    唐清碧; 明洪莉; 叶勇

    2013-01-01

    目的 探讨晚期食管癌经内镜下氩气刀联合局部分点注射5-FU加无水酒精治疗和经制定护理措施后,对改善患者的生活质量,提高护理满意度的效果.方法 对48例晚期食管癌患者,分为治疗组和对照组各24例,对照组行内科晚期食管癌传统常规护理模式及保守治疗;治疗组在传统护理模式的基础上加用专科护理及氩气刀联合5-FU加无水酒精治疗,比较两组的生活质量及护理满意度.结果 治疗组24例晚期食管癌患者在内镜下给予氩气刀2~3次烧灼联合分点局部注射5-FU加无水酒精经密切医护配合及专科护理,均获得满意疗效,生活质量改善,护理满意度明显提高,治疗组明显优于对照组,两组差异有统计学意义(P<0.05).绪论 内镜下氩气刀联合分点局部注射5-FU加无水酒精治疗晚期食管癌及癌性狭窄,经密切医护配合,充分的术前准备,术中术后护理,是手术成功的护理关键,可达到改善生活质量的目的,可在临床推广应用.%Objective To explore the nursing care of esophageal cancer after treatment with Argon plasma coagulation combined 5-FU plus anhydrous alcohol.Methods 48 cases of patients with advanced esophageal cancer were divided into treatment group and control group,24 cases each.The control group underwent internal medicine advanced esophageal conventional care model and conservative treatment; treatment group on the basis of the traditional model of care plus specialist care and argon the air knives joint 5-FU plus anhydrous alcohol treatment,the two groups were compared quality of life and care satisfaction.Results 24 patients with advanced esophageal cancer,including endoscopic given 2-3 times a burning joint points of argon plasma coagulation local injection of 5-FU plus anhydrous alcohol Satisfactory results were obtained by the close of health care co-ordination and specialist care,and improved quality of life,care satisfaction

  10. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not

  11. Curative effects of cryosurgery combined with argon plasma coagulation therapy for advanced central lung cancer by artificial trachea%经人工气道冷冻联合氩等离子电凝治疗晚期中央型肺癌的疗效分析

    Institute of Scientific and Technical Information of China (English)

    邱容; 肖昌武; 何正光; 文富强

    2013-01-01

    Objective To assess the feasibility,safety and clinical practicality value of cryosurgery combined with argon plasma coagulation(APC) therapy via bronchofibroscope for advanced central lung cancer by artificial trachea.Methods The clinical data of 41 cases of cryosurgery combined with argon plasma coagulation therapy via bronchofibroscope for advanced central lung cancer by artificial trachea from February 2011 to December 2012 were retrospectively analyzed.The curative effects were assessed before and after treatment.There were following evaluation indicators including preoperative,postoperative cough,hemoptysis,fever,dyspnea index,imaging examination,review of airway stenosis bronchoscopy etc.Results The research showed patients with cough relieving were 13 cases (31.7%),hemoptysis remission in 14 cases (34.1%),fever ease in 9 cases (22.0%),preoperative dyspnea index 3.5 ± 0.42,postoperative 1.8 ± 0.33,imaging suggestive of obstructive pneumonia and atelectasis disappeared in 12 cases (29.3%),27 cases (65.9%)improved,39 cases effective,2 cases no changes; bronchoscope checks completely effect in 17 cases (41.5%),partially effect in 21 cases (51.2%),invalid in 3 cases (7.3%).Conclusions cryosurgery combined with argon plasma coagulation therapy via bronchofibroscope for advanced central lung cancer by artificial trachea is feasible,safe and practical.It has the advantages of relieving cough,hemoptysis,fever,dyspnea,fewer complications etc,fewer complications and high security,which should be developed extensively in clinic.%目的 探讨经人工气道支气管镜下冷冻联合氩等离子电凝(APC)治疗晚期中央型肺癌的可行性、安全性.方法 回顾分析我院2011年2月至2012年12月经人工气道在支气管镜下对41例晚期中央型肺癌,行冷冻,并联合APC治疗的临床资料进行分析,术后一周评价疗效.评价指标包括术前、术后咳嗽、咯血、发热症状,呼吸困难指数、影像学检查、

  12. Perioperative coagulation management--fresh frozen plasma.

    Science.gov (United States)

    Kor, Daryl J; Stubbs, James R; Gajic, Ognjen

    2010-03-01

    Clinical studies support the use of perioperative fresh frozen plasma (FFP) in patients who are actively bleeding with multiple coagulation factor deficiencies and for the prevention of dilutional coagulopathy in patients with major trauma and/or massive haemorrhage. In these settings, current FFP dosing recommendations may be inadequate. However, a substantial proportion of FFP is transfused in non-bleeding patients with mild elevations in coagulation screening tests. This practice is not supported by the literature, is unlikely to be of benefit and unnecessarily exposes patients to the risks of FFP. The role of FFP in reversing the effects of warfarin anticoagulation is dependent on the clinical context and availability of alternative agents. Although FFP is commonly transfused in patients with liver disease, this practice needs broad reconsideration. Adverse effects of FFP include febrile and allergic reactions, transfusion-associated circulatory overload and transfusion-related acute lung injury. The latter is the most serious complication, being less common with the preferential use of non-alloimmunised, male-donor predominant plasma. FP24 and thawed plasma are alternatives to FFP with similar indications for administration. Both provide an opportunity for increasing the safe plasma donor pool. Although prothrombin complex concentrates and factor VIIa may be used as alternatives to FFP in a variety of specific clinical contexts, additional study is needed.

  13. Turbulence and transport in a magnetized argon plasma

    International Nuclear Information System (INIS)

    An experimental study on turbulence and transport in the highly ionized argon plasma of a hollow cathode discharge is described. In order to determine the plasma parameters three standard diagnostics have been used, whilst two diagnostics have been developed to study the plasma turbulence. (Auth.)

  14. Measurement of the argon plasma temperature by use of pyrometer

    International Nuclear Information System (INIS)

    The author describes in detail how to use pyrometer to measure the plasma temperature. The temperatures of shock-generated argon plasmas are given in the present work. Measured results of temperature-pressure curve are compared with calculated results using Saha-Debye-Huckel model, which are in good agreement

  15. Argon plasma coagulation and hyperbaric oxygen therapy in chronic radiation proctopathy, effectiveness and impact on tissue toxicity Argón plasma y oxígeno hiperbárico para el control de la rectorragia crónica secundaria a la proctopatía por radiación

    Directory of Open Access Journals (Sweden)

    Julio César Álvaro-Villegas

    2011-11-01

    Full Text Available Background: chronic radiation proctopathy (CRP is associated with recurrent rectal bleeding and transfusional requirements. Argon plasma coagulation (APC and hyperbaric oxygen therapy (HOT have been shown to be effective in the control of CRP. No prospective comparisons have been reported between these treatments. Aim: the aim was to evaluate the effectiveness, safety and impact on tissue toxicity of APC compared to HOT in patients with CRP. Material and methods: a prospective study for evaluating treatment response was conducted. Patients with cervical cancer and CRP with rectal bleeding were recruited. They had not received previous treatment. Collected data included: demographics, previous radiation dosage, duration and severity of rectal bleeding. Hemoglobin, transfusional requirements, and tissue toxicity (SOMA LENT questionnaire at baseline and at 1, 2, and 3 months follow up were recorded. Results: thirty-one patients were included, 14 in the APC group and 17 in the HOT group. No response was noted in 13 and 18% of patients in the APC and HOT group respectively (p = NS. At the 1 and 2 months follow-up, the APC group showed a significantly better response in terms of transfusional requirements (0.6 vs. 3.4 and 0.7 vs. 2.5 and tissue toxicity score (5.3 vs. 8.6 and 3.8 vs. 7.248. After 3 months, both groups showed further improvement in all parameters without significant differences between them. Conclusions: APC and HOT were effective, safe and decreased the tissue toxicity scores in patients with CRP. However, response rate was higher and faster in the APC group.Introducción: la proctopatía por radiación (PPR se asocia con rectorragía recurrente y requerimientos de trasfusiones. La coagulación con argón plasma (APC y la terapia con oxígeno hiperbárico (HOT han sido efectivas en el control de la PPR. No hay estudios prospectivos comparativos entre ambas técnicas. Objetivo: el objetivo del estudio es evaluar la efectividad

  16. Metastable argon beam source using a surface wave sustained plasma

    International Nuclear Information System (INIS)

    A new source of metastable argon atoms in the thermal energy range is reported. The source is based on expanding a plasma sustained by electromagnetic surface waves in a quartz tube through a converging nozzle and extracting a beam from the supersonic free-expansion jet. The beam was characterized by time-of-flight measurements which yielded the absolute intensity and velocity distribution of the argon metastables. The source produced a maximum intensity of 6.2x1014 metastables per second per steradian, the highest time-averaged intensity of thermal argon metastables of any source reported to date. A simple picture of an expanding plasma in a recombination regime is used to explain the dependence of the metastable intensity on absorbed power

  17. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  18. Optical emission spectroscopy of argon and hydrogen-containing plasmas

    Science.gov (United States)

    Siepa, Sarah; Danko, Stephan; Tsankov, Tsanko V.; Mussenbrock, Thomas; Czarnetzki, Uwe

    2015-09-01

    Optical emission spectroscopy (OES) on neutral argon is applied to investigate argon, hydrogen and hydrogen-silane plasmas. The spectra are analyzed using an extensive collisional-radiative model (CRM), from which the electron density and the electron temperature (or mean energy) can be calculated. The CRM also yields insight into the importance of different excited species and kinetic processes. The OES measurements are performed on pure argon plasmas at intermediate pressure. Besides, hydrogen and hydrogen-silane plasmas are investigated using argon as a trace gas. Especially for the gas mixture discharges, CRMs for low and high pressure differ substantially. The commonly used line-ratio technique is found to lose its sensitivity for gas mixture discharges at higher pressure. A solution using absolutely calibrated line intensities is proposed. The effect of radiation trapping and the shape of the electron energy distribution function on the results are discussed in detail, as they have been found to significantly influence the results. This work was supported by the Ruhr University Research School PLUS, funded by Germany's Excellence Initiative [DFG GSC 98/3].

  19. Tin LPP plasma control in the argon cusp source

    Science.gov (United States)

    McGeoch, Malcolm W.

    2016-03-01

    The argon cusp plasma has been introduced [1,2] for 500W class tin LPP exhaust control in view of its high power handling, predicted low tin back-scatter from a beam dump, and avoidance of hydrogen usage. The physics of tin ion control by a plasma is first discussed. Experimentally, cusp stability and exhaust disc geometry have previously been proved at full scale [2], the equivalent of 300W-500W usable EUV. Here we verify operation of the plasma barrier that maintains a high argon density next to the collector, for its protection, and a low density in the long path toward the intermediate focus, for efficiency. A pressure differential of 2Pa has been demonstrated in initial work. Other aspects of tin LPP plasma control by the cusp have now been demonstrated using tin ions from a low Hz 130mJ CO2 laser pulse onto a solid tin surface at the cusp center. Plasma is rejected at the design to match a specified exhaust power is discussed. In view of this work, argon cusp exhaust control appears to be very promising for 500W class tin LPP sources.

  20. Bacteria Inactivation Using DBD Plasma Jet in Atmospheric Pressure Argon

    Institute of Scientific and Technical Information of China (English)

    XU Guimin; ZHANG Guanjun; SHI Xingmin; MA Yue; WANG Ning; LI Yuan

    2009-01-01

    A coaxial dielectric barrier discharge plasma jet Was designed,which can be operated in atmospheric pressure argon under an intermediate frequency sinusoidal resonant power supply,and an atmospheric pressure glow-like discharge Was achieved.Two kinds of typical bacteria,i.e.,the Staphylococcus aureus(S.aurens)and Escherichia coil(E.coil),were employed to study the bacterial inactivation mechanism by means of the non-thermal plasma.The killing log value (KLV)of S.aureus reached up to 5.38 with a treatment time of 90 s and that of E.coil up to 5.36 with 60 s,respectively.According to the argon emission spectra of the plasma jet and the scanning electron microscope (SEM) images of the two bacteria before and after the plasma treatment.it is concluded that the reactive species in the argon plasma played a major role in the bacterial inactivation,while the heat,electric field and UV photons had little effect.

  1. Emission Rates in ASTRAL Argon Plasmas.

    Science.gov (United States)

    Kamar, Ola; Boivin, Robert; Loch, Stuart; Munoz, Jorge; Ballance, Connor

    2006-10-01

    Relative Emission rates measured in the ASTRAL (Auburn Steady sTate Research fAciLity) helicon plasma source are compared to theoretical predictions. A spectrometer which features a 0.33 m Criss-Cross Scanning monochromator and a CCD camera is used for this study. ASTRAL produces bright intense Ar plasmas with the following parameters: ne = 10^12 to 10^13 cm-3 and Te = 2 to 10 eV. A rf compensated Langmuir probe is used to measure Te and ne. In a first series of experiment Ar I, Ar II and Ar III transitions are monitored as a function of plasma density and this for constant electron temperature. In the second series of experiments, the same transitions are observed as a function of Te while ne is this time kept constant. Observations revealed that Te is by far the most significant parameter affecting the emission rate coefficients in the ASTRAL plasma. The spectroscopy measurements are compared with spectral modeling from the ADAS suite of codes. Our collisional-radiative formalism assumes that the excited levels are in quasi-static equilibrium with the ground and metastable populations. We use existing standard R-matrix electron-impact excitation data in our modeling, and assess this dataset against the results from a new R-matrix with pseudo-states calculation.

  2. Argon Plasma Coagulation Combined with Covered Stent Placement for Management of Tracheobronchial Stenoses/occlusions as well as Esophagorespiratory Fistulas%氩等离子体凝固联合分叉型被膜金属内支架置入治疗气管隆突周围复合狭窄和气管食管瘘

    Institute of Scientific and Technical Information of China (English)

    王洪武; 罗凌飞; 周云芝; 马洪明; 李晶; 邹珩; 李冬妹; 张楠

    2010-01-01

    背景与目的气管下端、隆突和双侧主支气管发生的狭窄称为多发性狭窄或复合狭窄,治疗非常棘手.本研究旨在探讨氩等离子体凝固(argon plasma coagulation,APC)联合分叉型被膜金属内支架(covered Z-type stents,CZTS)置入治疗气管隆突周围狭窄和气管食管瘘的安全性和疗效.方法回顾性分析32例气道病变的患者,在支气管镜引导下行APC,在X线透视和/或支气管镜引导下置入CZTS.结果 19例伴有气道狭窄的患者先行APC,术前气道狭窄发生率为57.4%-72.1%,术后均明显缓解(气道狭窄发生率仅为12.8%-25.8%).32例患者中30例技术上成功放置32个支架,2例失败.APC及成功放置支架的患者术后气促指数明显下降,KPS明显升高.13例气管下端瘘口置入分叉型CZTS,12例(92.3%)达临床治愈.术中、术后未出现大出血等并发症.两种术式术后短期内均产生大量分泌物,用气管镜可有效清除.置入内支架的患者1个月后易在支架两端形成肉芽,用APC结合冷冻可有效处理.结论使用APC联合CZTS置入治疗气道复合狭窄和气管食管瘘快速有效,安全可靠.

  3. Line ratio diagnostics in helium and helium seeded argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, R F [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Loch, S D [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Ballance, C P [Physics Department, Rollins College, White Park, FL 32789 (United States); Branscomb, D [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Pindzola, M S [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States)

    2007-08-15

    We investigate the potential use of line ratio diagnostics to evaluate electron temperature in either helium or helium seeded argon plasmas. Plasmas are produced in a helicon plasma source. A rf compensated Langmuir probe is used to measure both the electron temperature and plasma density while a spectrometer is used to measure He I line intensities from the plasma. For all plasma densities where the electron temperature remains at 5 {+-} 1 eV, three He line ratios are measured. Each experimental ratio is compared with the prediction of three different collisional radiative models. One of these models makes uses of recent R-matrix with pseudo-states calculations for collisional rate coefficients. A discussion related to the different observations and model predictions is presented.

  4. Study on tracheal intubation related severe subglottic stenosis under laryngeal mask by using holmium laser combined with argon plasma coagulation and cryotherapy through bronchoscopy%喉罩下经支气管镜钬激光联合氩气刀和二氧化碳冷冻治疗儿童获得性重度声门下狭窄

    Institute of Scientific and Technical Information of China (English)

    许煊; 祝彬; 石苗茜; 任海丽; 封志纯

    2015-01-01

    目的:探讨2例气管插管相关性重度声门下狭窄喉罩下支气管镜诊断及介入治疗的操作方法、有效性及安全性。方法2例男性患儿,年龄分别为4和11个月,因气管插管后出现脱机困难及呼吸困难,经CT及支气管镜检查,诊断为气管插管相关的重度声门下狭窄,在对家长进行详细告知支气管镜下介入手术不可预知情况并由家长签字同意后,遂对2例患儿进行经喉罩支气管镜下钬激光联合氩气刀和二氧化碳( CO2)冷冻治疗,分析患儿的临床资料、并发症及术后转归、随访情况。结果2例手术过程顺利,例1术后紧贴声门下的肉芽组织被完全清除,2例患儿声门下环形狭窄完全解除,治疗前呼吸道狭窄处周长约2.5 mm,治疗后,周长达5.2 mm,4.0 mm支气管镜进出无障碍,术后气管导管均成功拔除,呼吸困难均明显改善。2例患儿治疗后即刻、7 d、30 d和90 d镜下检查结果示狭窄处开放良好。术中有血氧饱和度下降及心率增快或减慢,暂停操作及恢复给氧后立即恢复,术中及术后未见异常血流动力学改变,2例目前仍在随访中。结论经喉罩钬激光、氩气刀及CO2冷冻治疗可用于后天性肉芽组织增生引起的声门下狭窄,方法安全、有效,近期效果显著,远期仍在进一步随访评估。%Objective To explore the operating methods,the effectiveness and safety for 2 cases of tracheal in-tubation related severe subglottic stenosis under laryngeal mask by using bronchoscopy in the diagnosis and interven-tional treatment. Methods Two male patients ( age at 4 and 11 months) both had difficulty breathing and weaning failure after endotracheal intubation,who were diagnosed with severe subglottic stenosis through CT and bronchoscopy examination. All parents signed their consent after being fully informed of treatment risks. Two cases were treated under bronchoscopic holmium laser combined with argon plasma coagulation and

  5. 喉罩下经支气管镜钬激光联合氩气刀和二氧化碳冷冻治疗儿童获得性重度声门下狭窄%Study on tracheal intubation related severe subglottic stenosis under laryngeal mask by using holmium laser combined with argon plasma coagulation and cryotherapy through bronchoscopy

    Institute of Scientific and Technical Information of China (English)

    许煊; 祝彬; 石苗茜; 任海丽; 封志纯

    2015-01-01

    目的:探讨2例气管插管相关性重度声门下狭窄喉罩下支气管镜诊断及介入治疗的操作方法、有效性及安全性。方法2例男性患儿,年龄分别为4和11个月,因气管插管后出现脱机困难及呼吸困难,经CT及支气管镜检查,诊断为气管插管相关的重度声门下狭窄,在对家长进行详细告知支气管镜下介入手术不可预知情况并由家长签字同意后,遂对2例患儿进行经喉罩支气管镜下钬激光联合氩气刀和二氧化碳( CO2)冷冻治疗,分析患儿的临床资料、并发症及术后转归、随访情况。结果2例手术过程顺利,例1术后紧贴声门下的肉芽组织被完全清除,2例患儿声门下环形狭窄完全解除,治疗前呼吸道狭窄处周长约2.5 mm,治疗后,周长达5.2 mm,4.0 mm支气管镜进出无障碍,术后气管导管均成功拔除,呼吸困难均明显改善。2例患儿治疗后即刻、7 d、30 d和90 d镜下检查结果示狭窄处开放良好。术中有血氧饱和度下降及心率增快或减慢,暂停操作及恢复给氧后立即恢复,术中及术后未见异常血流动力学改变,2例目前仍在随访中。结论经喉罩钬激光、氩气刀及CO2冷冻治疗可用于后天性肉芽组织增生引起的声门下狭窄,方法安全、有效,近期效果显著,远期仍在进一步随访评估。%Objective To explore the operating methods,the effectiveness and safety for 2 cases of tracheal in-tubation related severe subglottic stenosis under laryngeal mask by using bronchoscopy in the diagnosis and interven-tional treatment. Methods Two male patients ( age at 4 and 11 months) both had difficulty breathing and weaning failure after endotracheal intubation,who were diagnosed with severe subglottic stenosis through CT and bronchoscopy examination. All parents signed their consent after being fully informed of treatment risks. Two cases were treated under bronchoscopic holmium laser combined with argon plasma coagulation and

  6. Some transport properties in plasmas containing argon and fluorine

    Directory of Open Access Journals (Sweden)

    Novaković R.N.V.

    2003-01-01

    Full Text Available In this paper some results of numerical evaluation of transport coefficients in plasmas in the mixtures of argon and fluorine are presented. These transport characteristics are given in the function of the temperature for low pressures ranging from 0,1 kPa to 1,0 kPa and for low temperatures between 500 K and 5 000 K in argon plasmas with 20% and 30% of the fluorine added. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE is attained in it. The equilibrium plasma composition, necessary for the evaluations, was determined on the ground of the Saha equations for ionization processes and the law of mass action for the thermal dissociation of F2, combined with the charge conservation relation and the assumption that the pressure remained constant in the course of temperature variations. The ionization energy lowering, required in conjunction with the Saha equations, was obtained with the aid of a modified expression for the plasma Debye radius proposed previously. A previously derived expression for the modified Debye radius, offering the possibility to treat the plasmas considered as weakly non-ideal in the whole temperature range, is used. The cut-off at the Landau length rather than of the smallest of ionic radii is introduced. This alteration in the evaluation procedure brings different considerable changes in the final numerical results for the all relevant quantities.

  7. Numerical Modeling of an RF Argon-Silane Plasma with Dust Particle Nucleation and Growth

    Science.gov (United States)

    Girshick, Steven; Agarwal, Pulkit

    2012-10-01

    We have developed a 1-D numerical model of an RF argon-silane plasma in which dust particles nucleate and grow. This model self-consistently couples a plasma module, a chemistry module and an aerosol module. The plasma module solves population balance equations for electrons and ions, the electron energy equation under the assumption of a Maxwellian velocity distribution, and Poisson's equation for the electric field. The chemistry module treats silane dissociation and reactions of silicon hydrides containing up to two silicon atoms. The aerosol module uses a sectional method to model particle size and charge distributions. The nucleation rate is equated to the rates of formation of anions containing two Si atoms, and a heterogeneous reaction model is used to model particle surface growth. Aerosol effects considered include particle charging, coagulation, and particle transport by neutral drag, ion drag, electric force, gravity and Brownian diffusion. Simulation results are shown for the case of a 13.56 MHz plasma at a pressure of 13 Pa and applied RF voltage of 100 V (amplitude), with flow through a showerhead electrode. These results show the strong coupling between the plasma and the spatiotemporal evolution of the nanoparticle cloud.

  8. Observations of acoustic-wave-induced superluminescence in an argon plasma

    International Nuclear Information System (INIS)

    It is shown that in an argon discharge plasma it is possible to obtain overpopulation of certain electronic levels of atomic argon under the influence of acoustic waves. When the specified threshold is exceeded, then a superluminescence (in the form of light flashes) from the overpopulated electronic levels of atomic argon is observed

  9. 氩气刀配合分叉型被膜金属支架置入治疗气管隆突处狭窄16例%Argon plasma coagulation combined with bifurcated metal stents for treatment of airway stenosis in the carinal region A 16-case analysis

    Institute of Scientific and Technical Information of China (English)

    王洪武; 周云芝; 马洪明; 罗凌飞; 李晶; 邹珩; 李冬妹

    2009-01-01

    纳入16例气管隆突处气道狭窄患者,其中良性病变4例,恶件病变12例.对气道内病变先用氩等离子体凝固清除,随后放置气道分叉型金属支架.所选支架均为国产Z型不锈钢被膜支架.L型及I型支架均在软质气管镜引导下放置,Y型支架在气管镜和透视结合下放置.氩等离子体凝固治疗前气管、左、右主支气管的阻塞程度分别为(58.8±9.1)%,(67.4±7.4)%及(69.6±8.9)%,氩等离子体凝固首次消融后的阻塞程度分别为(7.5±2.4)%,(19.4±4.1)%及(27.6±5.4)%.所有患者胸闷、气憋症状均有明显改善,气促指数降低,体能状况Kamofsky评分增高.12例患者一次成功放置支架,其中9例为Y型:4例放置失败,其中2例肺癌患者隆突较宽,Y型支架难以置入,改用L型+I型.患者中位生存时间为10个月,平均生存时间为13个月.结果提示,氩等离子体凝固结合分叉型被膜金属支架置入治疗气管隆突处狭窄可以改善患者梗阻症状,提高生活质量.%A total of 16 patients with airway stenosis including benign lesion (n=4) and malignant disease (n=12) were treated with argon plasma coagulation (APC) and Z-type covered retrievable metallic stent.L-and I-type stents were placed by guidance of brenchoscope,while Y-type stent was placed by the guidance of both bronchoscope and fluoroscope.Airway stenosis was from (58.8 +9.1)% before APC to (7.5±2.4)% after APC in tracheal,from (67.4±7.4)% to (19.4±4.1)% in left main bronchus,from (69.6±8.9)% to (27.6±5.4)% in right main bronchus.Symptoms of chest distress and breathlessness were improved remarkably,tachypnea indexes were decreased,but Kamofsky performance scope were increased.Twelve stents were successfully installed by the first time,including 9 Y-shape;otherwise,4 stents failed to be installed because the carinal was too wide to insert the Y-shape stent in two patients with lung cancer,finally,L+I type stents were used.Median survival time after successful

  10. Characterization of SF6/Argon Plasmas for Microelectronics Applications; TOPICAL

    International Nuclear Information System (INIS)

    This report documents measurements in inductively driven plasmas containing SF(sub 6)/Argon gas mixtures. The data in this report is presented in a series of appendices with a minimum of interpretation. During the course of this work we investigated: the electron and negative ion density using microwave interferometry and laser photodetachment; the optical emission; plasma species using mass spectrometry, and the ion energy distributions at the surface of the rf biased electrode in several configurations. The goal of this work was to assemble a consistent set of data to understand the important chemical mechanisms in SF(sub 6) based processing of materials and to validate models of the gas and surface processes

  11. A Thermodynamic Model for Argon Plasma Kernel Formation

    Directory of Open Access Journals (Sweden)

    James Keck

    2010-11-01

    Full Text Available Plasma kernel formation of argon is studied experimentally and theoretically. The experiments have been performed in a constant volume cylindrical vessel located in a shadowgraph system. The experiments have been done in constant pressure. The energy of plasma is supplied by an ignition system through two electrodes located in the vessel. The experiments have been done with two different spark energies to study the effect of input energy on kernel growth and its properties. A thermodynamic model employing mass and energy balance was developed to predict the experimental data. The agreement between experiments and model prediction is very good. The effect of various parameters such as initial temperature, initial radius of the kernel, and the radiation energy loss have been investigated and it has been concluded that initial condition is very important on formation and expansion of the kernel.

  12. Nonthermal Argon Plasma Generator and Some Potential Applications

    Directory of Open Access Journals (Sweden)

    Bunoiu M.

    2015-12-01

    Full Text Available A laboratory - made nonthermal plasma generator is presented. It has a diameter of 0.020 m and length of 0.155 m and contains two electrodes. The first electrode is a 2% Th-W alloy, 0.002 m in diameter bar, centred inside the generator’s body by means of a four channel teflon piece; the other three channels, 0.003 m in diameter, are used for Ar supply. The second electrode is a nozzle of 0.002 m - 0.008 m diameter and 0.005m length. A ~500 kV/m electric field is generated between the two electrodes by a high frequency source (13.56 MHz ±5%, equipped with a OT-1000 (Tungsram power triode. For Ar flows ranging from 0.00008 m3/s to 0.00056 m3/s, a plasma jet of length not exceeding 0.015 m and temperature below 315 K is obtained. Anthurium andraeanumis sample , blood matrix, human hair and textile fibers may be introduced in the plasma jet. For time periods of 30 s and 60 s, various effects like, cell detexturization, fast blood coagulation or textile fiber or hair cleaning and smoothing are obtained. These effects are presented and discussed in the paper.

  13. An update of argon inelastic cross sections for plasma discharges

    International Nuclear Information System (INIS)

    This paper proposes a coherent set of electron impact inelastic cross sections for argon, based on recent experimental measurements. The updated set is validated by comparing calculated swarm parameters and rate coefficients (obtained by solving the two-term approximation electron Boltzmann equation) with available experimental data. This validation procedure is usually adopted when the cross section set is to be later used in plasma discharge modelling. Simulation results for the electron drift velocity and characteristic energy are in very good agreement with experimental values of these quantities. Calculations, using cross section sets proposed by different authors, of the total (direct + cascade) excitation coefficients to the 4s and 4p states, and of the Townsend ionization coefficient, show that the present set ensures the best overall agreement with measured values. The agreement is particularly good for the excitation coefficient to metastable 4s'[1/2]0 and the Townsend ionization coefficient, which are probably the most relevant electron macroscopic coefficients in the modelling of discharge plasmas

  14. Plasma fibronectin concentrations in dogs with disseminated intravascular coagulation.

    Science.gov (United States)

    Feldman, B F; Thomson, D B; O'Neill, S

    1985-05-01

    Plasma fibronectin concentrations were significantly (P less than 0.001) below the reference range in dogs with disseminated intravascular coagulation (DIC) secondary to nonlymphomatous neoplasia, acute necrotizing pancreatitis, sepsis, chronic active hepatitis, and heat stroke. There was no statistical evidence of a group effect. Decrease in fibronectin concentration was associated with severe DIC, although no attempt was made to correlate fibronectin concentration with prognosis. These findings parallel those reported for severely ill human beings with diseases associated with DIC. They exemplify the potential of spontaneous diseases in animals as models for the study of human disease. PMID:4003893

  15. Effect of taurine on platelets and the plasma coagulation system.

    Science.gov (United States)

    Miglis, Mitchell; Wilder, Donna; Reid, Thomas; Bakaltcheva, Irina

    2002-02-01

    It is not yet clear what exact mechanisms are at work in hibernating animals that prevent clot formation and maintain tissue perfusion under conditions of very slow blood flow and increased blood viscosity brought about by the low temperatures. It has been shown that the total amino acid pool increases more then two fold in hibernating animals with taurine accounting for about 50% of this increase [Storey et al., Proc Natl Acad Sci USA 1988; 85(21): 8350-4]. This work investigates the effect of taurine on platelets and the plasma coagulation system. Taurine was added at different concentrations in the range between 5 and 25 mM to donor plasma. Using STA/STA Compact coagulation analyzer the following tests were performed: prothrombin time (PT), activated partial thromboplastin time (APTT), and thrombin time (TT). At the highest concentration tested (25 mM) taurine prolonged TT by 9%. The prolongation was statistically significant but not clinically significant retaining TT within normal limits (16.7-20.7 s). PT and APTT remained unchanged by taurine. The effect of taurine on platelets was assessed by platelet aggregation by thrombin, extent of platelet shape change (ESC) induced by ADP, and thrombelastography. Taurine at 5 mM final concentration inhibited platelet aggregation by 10%. Increasing taurine concentration to 25 mM did not result in a further augmentation of the inhibitory effect. ESC was unaffected by taurine. Clot strength determined by thrombelastography also remained unchanged by taurine. PMID:11918831

  16. Characterisation of an RF excited argon plasma cathode electron beam gun

    OpenAIRE

    Del Pozo, S.; Ribton, C; Smith, DR

    2014-01-01

    This work describes the experimental set up used for carrying out spectroscopic measurements in a plasma cathode electron beam (EB) gun. Advantages of plasma cathode guns over thermionic guns are described. The factors affecting electron beam power such as plasma pressure, excitation power and plasma chamber geometry are discussed. The maximum beam current extracted was 53 mA from a 0.5 mm diameter aperture in the plasma chamber. In this work, the electron source is an argon plasma excited at...

  17. Radiating plasma species density distribution in EUV-induced plasma in argon: a spatiotemporal experimental study

    Science.gov (United States)

    van der Horst, R. M.; Beckers, J.; Osorio, E. A.; van de Ven, T. H. M.; Banine, V. Y.

    2015-12-01

    In this contribution we experimentally study temporally and spatially resolved radiating plasma species density distribution in plasma induced by irradiating a low pressure argon gas with high energy photons with a wavelength of 13.5 nm, i.e. extreme ultraviolet (EUV). This is done by recording the optical emission spatially and temporally resolved by an iCCD camera as a function of the argon gas pressure. Our experimental results show that the emission intensity, i.e. density of radiating plasma species, depends quadratically on the gas pressure. The linear term is due to photoionization and simultaneous excitation by EUV photons, the quadratic term due to electron impact excitation by electrons generated by photoionization. The decay of radiating plasma species can be divided into two phases. At time scales shorter than 10 μs (first phase), the decay is governed by radiative decay of radiating plasma species. At longer time scales (second phase, >10 μs), the decay is dominated by diffusion and subsequent de-excitation at the wall. The experimental decay and expansion during this phase corresponds well with a simplified diffusion model. In order to gain more insight in this exotic type of plasma, we compare the electron density from previous measurements with the results obtained here.

  18. Common versus noble Bacillus subtilis differentially responds to air and argon gas plasma.

    Science.gov (United States)

    Winter, Theresa; Bernhardt, Jörg; Winter, Jörn; Mäder, Ulrike; Schlüter, Rabea; Weltmann, Klaus-Dieter; Hecker, Michael; Kusch, Harald

    2013-09-01

    The applications of low-temperature plasma are not only confined to decontamination and sterilization but are also found in the medical field in terms of wound and skin treatment. For the improvement of already established and also for new plasma techniques, in-depth knowledge on the interactions between plasma and microorganism is essential. In an initial study, the interaction between growing Bacillus subtilis and argon plasma was investigated by using a growth chamber system suitable for low-temperature gas plasma treatment of bacteria in liquid medium. In this follow-up investigation, a second kind of plasma treatment-namely air plasma-was applied. With combined proteomic and transcriptomic analyses, we were able to investigate the plasma-specific stress response of B. subtilis toward not only argon but also air plasma. Besides an overlap of cellular responses due to both argon and air plasma treatment (DNA damage and oxidative stress), a variety of gas-dependent cellular responses such as growth retardation and morphological changes were observed. Only argon plasma treatments lead to a phosphate starvation response whereas air plasma induced the tryptophan operon implying damage by photooxidation. Biological findings were supported by the detection of reactive plasma species by optical emission spectroscopy and Fourier transformed infrared spectroscopy measurements. PMID:23794223

  19. Surface compositional changes in GaAs subjected to argon plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Surdu-Bob, C.C.; Sullivan, J.L.; Saied, S.O.; Layberry, R.; Aflori, M

    2002-12-30

    X-ray photoelectron spectroscopy (XPS) has been employed to study surface compositional changes in GaAs (1 0 0) subjected to argon plasma treatment. The experimental results have been explained in terms of predicted argon ion energies, measured ion densities and etch rates. A model is proposed for the processes taking place at the surface of GaAs in terms of segregation, sputtering and surface relaxation. Stopping and range of ions in matter (SRIM) code has also been employedan aid to identification of the mechanisms responsible for the compositional changes. Argon plasma treatment induced surface oxidation at very low energies and sputtering and surface damage with increasing energy.

  20. Surface modification of polypropylene using argon plasma: Statistical optimization of the process variables

    International Nuclear Information System (INIS)

    Low pressure plasma treatment using radiofrequency (rf) discharge of argon gas was employed to improve the hydrophilicity of polypropylene. The effects of argon plasma on the wettability, surface chemistry and surface morphology of polypropylene were studied using static contact angle measurements, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Increase in surface energy of polypropylene was observed as a result of argon plasma treatment. SEM and AFM images revealed the increased surface roughness. A set of identified process variables (rf power, pressure, argon flow rate and time) were used in this study and were optimized using central composite design (CCD) of response surface methodology (RSM). A statistical model was developed to represent the surface energy in terms of the process variables mentioned above. Accuracy of the model was verified and found to be high.

  1. Surface modification of poly (vinyl chloride) by long-distance and direct argon RF plasma

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper reports the effects of long- distance and direct argon radio frequency (RF) plasma surface treatment on polyvinyl chloride (PVC) films in terms of changes in surface wettability and surface chemistry. The surface properties are characterized by the water contact angle measurement, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The mechanism is further analyzed and the role of all kinds of active species, e.g. electrons, ions and free radicals involved in plasma surface modification is further evaluated. Results show that the long-distance and direct RF plasma treatments modify the PVC surface in morphology and composition, and both modifications cause surface oxidation of PVC films, in the forming of functional groups enhancing polymer wettability. The effect of the long-distance argon RF plasma is more notable. This suggests that long-distance argon RF plasma could restrain the ion and electron eroding effect and enhance free radical reaction.

  2. The effect of potassium addition on plasma parameters in argon dc plasma arc

    Energy Technology Data Exchange (ETDEWEB)

    Rankovic, D; Kuzmanovic, M [Faculty of Physical Chemistry, University of Belgrade, PO Box 137, 11000 Belgrade (Serbia); Savovic, J; Pavlovic, M S; Stoiljkovic, M; Momcilovic, M, E-mail: dragan@ffh.bg.ac.r [Laboratory of Physical Chemistry, Institute Vinca, University of Belgrade, PO Box 522, 11001 Belgrade (Serbia)

    2010-08-25

    The effect of potassium addition on the radial distribution of temperature and electron number density in a U-shaped direct current (dc) argon plasma operating at different arc currents has been studied by optical emission spectroscopic techniques and the power interruption method. Spatially resolved electron number densities (n{sub e}) have been determined from measured radial profiles of Balmer-H{sub {beta}} spectral line. The obtained electron number densities have been used for thermodynamic temperature (T{sub LTE}) evaluation with the assumption that the arc plasma is in a state of local thermodynamic equilibrium. The excitation temperatures (T{sub exc}) have been determined from the absolute integral emissivity of the argon line at 430.01 nm. For heavy particle temperature (T{sub h}) evaluations we have used a power interruption method. The obtained results have shown that an addition of KCl decreases both electron number density and temperature of the arc column. The magnitude of such an influence on plasma parameters increases with an increase in the KCl concentration and decreases with an increase in the arc current.

  3. Simulations of geometrically pinched argon plasmas using an extended one-dimensional model

    NARCIS (Netherlands)

    K.T.A.L. Burm,; W. J. Goedheer,; D.C. Schram,

    2001-01-01

    The subject of this paper is the modelling of a wall-stabilized cylinder symmetric cascaded are which is to be used as a high-density plasma source. To enhance the ion flux emerging from cascaded are argon plasmas the confining wall can be changed into a nozzle geometry. Such pinched geometries incr

  4. Coherent and incoherent Thomson scattering on an argon/hydrogen microwave plasma torch with transient behaviour

    Science.gov (United States)

    Obrusník, A.; Synek, P.; Hübner, S.; van der Mullen, J. J. A. M.; Zajíčková, L.; Nijdam, S.

    2016-10-01

    A new method of processing time-integrated coherent Thomson scattering spectra is presented, which provides not only the electron density and temperature but also information about the transient behaviour of the plasma. Therefore, it is an alternative to single-shot Thomson scattering measurements as long as the scattering is coherent. The method is applied to a microwave plasma torch operating in argon or a mixture of argon with hydrogen at atmospheric pressure. Electron densities up to 8\\cdot {{10}21} m-3 (ionization degree above 10-3) were observed, which is more than two times higher than presented in earlier works on comparable discharges. Additionally, a parametric study with respect to the argon/hydrogen ratio and the input power was carried out and the results are discussed together with earlier Stark broadening measurements on the same plasma.

  5. Gas temperature effect on the time for onset of particle nucleation in argon diluted acetylene plasma

    CERN Document Server

    Stefanovic, I; Berndt, J; Winter, J; Stefanovic, Ilija; Kovacevic, Eva; Berndt, Johannes; Winter, Jorg

    2004-01-01

    In our work we are focused on study of powder formation in C2H2/Ar plasmas. In this scope we used a combination of FTIR and mass spectroscopy, which are the mostly used experimental techniques for plasma powder formation diagnostics. To test the proposed mechanism for particle nucleation delay we measured the particle nucleation under different plasma conditions: firstly we increased the gas temperature and secondly we changed the background gas from argon to helium.

  6. Surface modification of fluorosilicone acrylate RGP contact lens via low-temperature argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Yin Shiheng [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Analytical and Testing Center, South China University of Technology, Guangzhou 510640 (China); Wang Yingjun [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Ren Li [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China)], E-mail: psliren@scut.edu.cn; Zhao Lianna [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Kuang Tongchun [Analytical and Testing Center, South China University of Technology, Guangzhou 510640 (China); Chen Hao [Wenzhou Medical College, Wenzhou 325035 (China)], E-mail: chenhao823@mail.wz.zj.cn; Qu Jia [Wenzhou Medical College, Wenzhou 325035 (China)

    2008-11-15

    A fluorosilicone acrylate rigid gas permeable (RGP) contact lens was modified via argon plasma to improve surface hydrophilicity and resistance to protein deposition. The influence of plasma treatment on surface chemical structure, hydrophilicity and morphology of RGP lens was investigated by X-ray photoelectron spectrometer (XPS), contact angle measurements and scanning electron microscope (SEM), respectively. The contact angle results showed that the hydrophilicity of the contact lens was improved after plasma treatment. XPS results indicated that the incorporation of oxygen-containing groups on surface and the transformation of silicone into hydrophilic silicate after plasma treatment are the main reasons for the surface hydrophilicity improvement. SEM results showed that argon plasma with higher power could lead to surface etching.

  7. Influence of dissociative recombination on the LTE of argon high-frequency plasmas at atmospheric pressure

    CERN Document Server

    Sainz, A; García, M C; Calzada, M D; Sainz, Abel; Margot, Joelle; Garcia, Maria Carmen; Calzada, Maria Dolores

    2004-01-01

    This work presents a few preliminary results from a collisional-radiative (CR) model intended to describe an argon microwave (2.45 GHz) plasma at atmospheric pressure. This model aims to investigate the influence of dissociative recombination products on the Saha-Boltzmann plasma equilibrium. The model is tested through comparison with experimental results obtained in an argon plasma column generated by a traveling electromagnetic surface-wave, which is suitable to perform a parametric investigation of the plasma. It is shown that dissociative recombination predominantly populates the 4s levels and the ground state. It is further observed that it strongly influences the population of the levels, specially those of lower energy. However, the higher levels (close to the ionization limit) appear to be in equilibrium whatever the plasma density. This allows assuming that the excitation temperature Texc determined from the upper levels in the atomic system in the Boltzmann-plot is equal to Te.

  8. CFD Simulation of a Hydrogen/Argon Plasma Jet Reactor for Coal Pyrolysis

    Institute of Scientific and Technical Information of China (English)

    CHEN H. G.; XIE K. C.

    2004-01-01

    A Computational Fluid Dynamics (CFD) model was formulated for DC arc hydrogen/argon plasma jet reactors used in the process of the thermal H2/Ar plasma pyrolysis of coal to acetylene. In this model, fluid flow, convective heat transfer and conjugate heat conductivity are considered simultaneously. The error caused by estimating the inner-wall temperature of a reactor is avoided. The thermodynamic and transport properties of the hydrogen/argon mixture plasma system, which are usually expressed by a set of discrete dats, are fitted into expressions that can be easily implemented in the program. The effects of the turbulence are modeled by two standard k-s equations. The temperature field and velocity field in the plasma jet reactor were calculated by employing SIMPLEST algorithm. The knowledge and insight obtained are useful for the design improvement and scale-up of plasma reactors.

  9. Impact of an atmospheric argon plasma jet on a dielectric surface and desorption of organic molecules

    Science.gov (United States)

    Damany, Xavier; Pasquiers, Stéphane; Blin-Simiand, Nicole; Bauville, Gérard; Bournonville, Blandine; Fleury, Michel; Jeanney, Pascal; Santos Sousa, João

    2016-08-01

    The propagation of a DC-pulsed argon plasma jet through the surrounding ambient air, and its interaction with an ungrounded glass plate placed on the jet trajectory, was studied by means of fast imaging. The surface plays an important role in the spatio-temporal characteristics of the plasma. Indeed, for an argon jet propagating perpendicularly to the surface, the plasma jet structure changes from filamentary to diffuse when the distance between the nozzle of the capillary tube and the surface is short (≤10 mm). Changing the angle between the capillary tube and the glass plate, and varying the gas flow rate strongly affects the spatial extension of the plasma that develops on the surface. This surface plasma propagates while the plasma in the argon jet is maintained with the same luminous intensity. Finally, this plasma jet shows interesting characteristics for desorption of low volatile organic molecules such as bibenzyl. A maximum removal of bibenzyl is located at the intersection area between the jet axis and the glass surface, and some of the initially deposited molecules are found intact in gas phase. Contribution to the topical issue "6th Central European Symposium on Plasma Chemistry (CESPC-6)", edited by Nicolas Gherardi, Ester Marotta and Cristina Paradisi

  10. Electron Temperature Control in Inductively Coupled Nitrogen Plasmas by Adding Argon/Helium

    Institute of Scientific and Technical Information of China (English)

    康正德; 蒲以康

    2002-01-01

    A new technique, adding argon or helium into nitrogen plasma, has been used to regulate the electron temperature in an inductively coupled plasma. The electron temperature is determined by analysing the intensity ratio of two nitrogen spectrum lines. The results show that, when the total pressure is 0.7Pa, the electron temperature increases with the increase of the He partial pressure in He/N2 plasma, but the electron temperature decreases with the increase of the Ar partial pressure in Ar/N2 plasma. The regulation effect of electron temperature is weaker in higher pressure N2/He plasma of 2.6Pa.

  11. Ionic Wind Phenomenon and Charge Carrier Mobility in Very High Density Argon Corona Discharge Plasma

    Science.gov (United States)

    Nur, M.; Bonifaci, N.; Denat, A.

    2014-04-01

    Wind ions phenomenon has been observed in the high density argon corona discharge plasma. Corona discharge plasma was produced by point to plane electrodes and high voltage DC. Light emission from the recombination process was observed visually. The light emission proper follow the electric field lines that occur between point and plane electrodes. By using saturation current, the mobilities of non-thermal electrons and ions have been obtained in argon gas and liquid with variation of density from 2,5 1021 to 2 1022 cm-3. In the case of ions, we found that the behaviour of the apparent mobility inversely proportional to the density or follow the Langevin variation law. For non-thermal electron, mobility decreases and approximately follows a variation of Langevin type until the density <= 0,25 the critical density of argon.

  12. On the plasma chemistry of a cold atmospheric argon plasma jet with shielding gas device

    Science.gov (United States)

    Schmidt-Bleker, Ansgar; Winter, Jörn; Bösel, André; Reuter, Stephan; Weltmann, Klaus-Dieter

    2016-02-01

    A novel approach combining experimental and numerical methods for the study of reaction mechanisms in a cold atmospheric \\text{Ar} plasma jet is introduced. The jet is operated with a shielding gas device that produces a gas curtain of defined composition around the plasma plume. The shielding gas composition is varied from pure {{\\text{N}}2} to pure {{\\text{O}}2} . The density of metastable argon \\text{Ar}≤ft(4\\text{s}{{,}3}{{\\text{P}}2}\\right) in the plasma plume was quantified using laser atom absorption spectroscopy. The density of long-living reactive oxygen and nitrogen species (RONS), namely {{\\text{O}}3} , \\text{N}{{\\text{O}}2} , \\text{NO} , {{\\text{N}}2}\\text{O} , {{\\text{N}}2}{{\\text{O}}5} and {{\\text{H}}2}{{\\text{O}}2} , was quantified in the downstream region of the jet in a multipass cell using Fourier-transform infrared spectroscopy (FTIR). The jet produces a turbulent flow field and features guided streamers propagating at several \\text{km}~{{\\text{s}}-1} that follow the chaotic argon flow pattern, yielding a plasma plume with steep spatial gradients and a time dependence on the \\text{ns} scale while the downstream chemistry unfolds within several seconds. The fast and highly localized electron impact reactions in the guided streamer head and the slower gas phase reactions of neutrals occurring in the plasma plume and experimental apparatus are therefore represented in two separate kinetic models. The first electron impact reaction kinetics model is correlated to the LAAS measurements and shows that in the guided streamer head primary reactive oxygen and nitrogen species are dominantly generated from \\text{Ar}≤ft(4\\text{s}{{,}3}{{\\text{P}}2}\\right) . The second neutral species plug-flow model hence uses an \\text{Ar}≤ft(4\\text{s}{{,}3}{{\\text{P}}2}\\right) source term as sole energy input and yields good agreement with the RONS measured by FTIR spectroscopy.

  13. Arc Root Motions in an Argon-Hydrogen Direct-Current Plasma Torch at Reduced Pressure

    Institute of Scientific and Technical Information of China (English)

    HUANG He-Ji; PAN Wen-Xia; WU Cheng-Kang

    2008-01-01

    Arc root motions in generating dc argon hydrogen plasma at reduced pressure are optically observed using a high-speed video camera. The time resolved angular position of the arc root attachment point is measured and analysed. The arc root movement is characterized as a chaotic and jumping motion along the circular direction on the anode surface.

  14. Experimental investigation of MHD impact on argon plasma flows by variation of magnetic flux density

    OpenAIRE

    Knapp, A.; Fulge, Hannes; Herdrich, Georg; Ono, N.; Wernitz, Ricarda; AUWETER-KURTZ, Monika; Röser, Hans-Peter; Fasoulas, Stefanos

    2012-01-01

    The interaction between a probe body and argon plasma flow is investigated to examine to what extent the probe head temperature and the bow shock distance can be influenced by applying a strong magnetic field. The experiments are performed using a strong permanent magnet installed inside a probe body with a spherical, coated probe head. Former investigations showed strong influence on the bow shock geometry but also on the inflow plasma jet. Several boundary conditions have been varied to eva...

  15. Emission Spectroscopy of OH Radical in Water-Argon Arc Plasma Jet

    OpenAIRE

    Alan Mašláni; Viktor Sember

    2014-01-01

    Emission spectra of OH radical are studied in the plasma jet generated by a plasma torch with hybrid water-argon stabilization. Plasma jet is located in a chamber with pressures 4 kPa and 10 kPa. In spite of high temperatures of produced plasma, OH spectra are observed in a large area of the jet. OH spectra are used to obtain rotational temperatures from the Boltzmann plots of resolved rotational lines. Due to line-of-sight integration of radiation, interpretation of the temperatures is not s...

  16. Calculation of ion energy distributions of argon excimer ions generated in helicon plasma

    Institute of Scientific and Technical Information of China (English)

    Fang Tong-Zhen; Jiang Nan; Wang Long

    2005-01-01

    A program is developed to calculate the ion energy distributions (IEDs) of Ar2+ making use of a simplified kinetic model with a combination of Monte Carlo method. Several coefficients are used to realize good match between the calculated and measured results. Some important assumptions are confirmed: argon excimer ions have short lifetime,hence they are formed in a short range before the collecting electrode. The excimer ions that encounter collisions will be discarded because they turn to other ion species after they collide with argon atoms. From the calculated results some plasma parameters such as the cross section or neutral density in discharge could be evaluated.

  17. Plasma and plasma components in the management of disseminated intravascular coagulation

    NARCIS (Netherlands)

    M. Levi; E. de Jonge; T. van der Poll

    2006-01-01

    A variety of clinical conditions can cause systemic activation of coagulation that ranges from insignificant laboratory changes to severe disseminated intravascular coagulation (DIC). DIC consists of a widespread systemic activation of coagulation, resulting in diffuse fibrin deposition in small and

  18. Diagnosis of the Argon Plasma in a PECVD Coating Machine

    Institute of Scientific and Technical Information of China (English)

    WANG Qing; BA Dechun; FENG Jian

    2008-01-01

    A Langmuir probe plasma diagnostic system was developed to measure the plasma parameters in a PECVD vacuum coating machine. The plasma was a capacitively coupled plasma (CCP) driven by a radio-frequency (RF) power supply. To avoid the disturbanqe of radio-frequency field on the Langmuir probe measurement, a passive compensation method was applied. This method allowed the 'dc' component to be passed and measured in the probe circuit. It was found that the electron temperature in the range from 2.7 eV to 6.4 eV decreased with the increase in RF power. The measured plasma density ranged from 8×1016 m-3 to 0.85×1015 m-3 and increased with the increase in RF power.

  19. Rotational and Vibrational Temperatures of Atmospheric Double Arc Argon-Nitrogen Plasma

    Institute of Scientific and Technical Information of China (English)

    YAN Jian-Hua; TU Xin; MA Zeng-Yi; CEN Ke-Fa; B.G.Chéron

    2007-01-01

    The spectroscopic technique is employed to study the emission of atmospheric argon-nitrogen plasma jet generated by an original dc double anode plasma torch. The molecular bands of the N(+2) first negative system are observed at the torch exit and chosen to evaluate the rotational and vibrational temperatures in comparison with the simulated spectra. The excitation temperature (Texc≈9600 K) is determined from the Boltzmann plot method. The results show that the rotational, vibrational, electron and kinetic temperatures are in good agreement with one another, which indicates that the core region of atmospheric double arc argon-nitrogen plasma jet at the torch exit is close to the local thermodynamic equilibrium state under our experimental conditions.

  20. Plasma Diagnostics Using K-Line Emission Profiles of Argon

    CERN Document Server

    Chen, Yiling; Reinholz, Heidi; Röpke, Gerd

    2014-01-01

    K-line profiles emitted from a warm dense plasma environment are used for diagnostics of Ar droplet plasmas created by high energy laser pulses. We observe temperature gradients within the Ar droplet from cold temperatures of the order of some 10 eV up to higher temperatures of about 170 eV. Non-perturbative wave functions are calculated as well as ionization energies, binding energies and relevant emission energies using a chemical {\\it ab initio} code. The plasma screening is considered within a perturbative approach to the Hamiltonian. The plasma effect influences the many-particle system resulting in energy shifts due to electron-ion and electron-electron interaction. With this approach we get a good reproduction of spectral features that are strongly influenced by ionization and excitation processes within the plasma. Comparing with the widely known FLYCHK code, counting for internal degrees of freedom (bound states) and treating pressure ionization within our quantum statistical approach leads to differ...

  1. Surface modification of ultra-high molecular weight polyethylene (UHMWPE) by argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Liu Hengjun; Pei Yanan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Xie Dong [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031 (China); Deng Xingrui [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Leng, Y.X., E-mail: yxleng@263.net [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Jin Yong, E-mail: jyct@163.com [Interventional Therapy Department, The Second Affiliated Hospital, Soochow University, Suzhou 215004 (China); Huang Nan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China)

    2010-04-01

    In this work, argon (Ar) plasma generated by microwave electron cyclotron resonance (MWECR) has been used to modify the UHMWPE in order to increase the wear resistance. The results showed that the wettability, anti-scratch and wear resistance of UHMWPE treated by the Ar plasma had been improved, comparing with native UHMWPE. The FTIR and XPS spectra indicated the improvement of wettability should come from the oxygen based functional groups generated on the surface of UHMWPE. The improvement of anti-scratch and wear resistance may come from the enhancement of crosslinking of UHMWPE by Ar plasma treatment.

  2. Surface modification of ultra-high molecular weight polyethylene (UHMWPE) by argon plasma

    International Nuclear Information System (INIS)

    In this work, argon (Ar) plasma generated by microwave electron cyclotron resonance (MWECR) has been used to modify the UHMWPE in order to increase the wear resistance. The results showed that the wettability, anti-scratch and wear resistance of UHMWPE treated by the Ar plasma had been improved, comparing with native UHMWPE. The FTIR and XPS spectra indicated the improvement of wettability should come from the oxygen based functional groups generated on the surface of UHMWPE. The improvement of anti-scratch and wear resistance may come from the enhancement of crosslinking of UHMWPE by Ar plasma treatment.

  3. Influence of argon plasma treatment on polyethersulphone surface

    Indian Academy of Sciences (India)

    N L Singh; S M Pelagade; R S Rane; S Mukherjee; U P Deshpande; V Ganeshan; T Shripathi

    2013-01-01

    Polyethersulphone (PES) was modified to improve the hydrophilicity of its surface, which in turn helps in improving its adhesive property. The modified PES surface was characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and Vicker’s microhardness measurement. The contact angles of the modified PES reduces from 49° to 10° for water. The surface free energy (SFE) calculated from measured contact angles increases from 66.3 to 79.5 mJ/m2 with the increase in plasma treatment time. The increase in SFE after plasma treatment is attributed to the functionalization of the polymer surface with hydrophilic groups. The XPS analysis shows that the ratio of O/C increases from 0.177 to 0.277 for modified PES polymer. AFM shows that the average surface roughness increases from 6.9 nm to 23.7 nm due to the increase in plasma treatment time. The microhardness of the film also increases with plasma treatment.

  4. Risk assessment of a cold argon plasma jet in respect to its mutagenicity.

    Science.gov (United States)

    Wende, K; Bekeschus, S; Schmidt, A; Jatsch, L; Hasse, S; Weltmann, K D; Masur, K; von Woedtke, T

    2016-03-01

    Cold atmospheric pressure plasmas represent a favorable option for the treatment of heat sensitive materials and human or animal tissue. Beneficial effects have been documented in a variety of medical conditions, e.g., in the treatment of chronic wounds. It is assumed that the main mechanism of the plasma's efficacy is mediated by a stimulating dissipation of energy via radiation and/or chemical energy. Although no evidence on undesired side effects of a plasma treatment has yet been presented, skepticism toward the safety of the exposure to plasma is present. However, only little data regarding the mutagenic potential of this new treatment option is available. Accordingly, we investigated the mutagenic potential of an argon plasma jet (kinpen) using different testing systems in accordance with ISO norms and multiple cell lines: a HPRT1 mutation assay, a micronucleus formation assay, and a colony formation assay. Moderate plasma treatment up to 180 s did not increase genotoxicity in any assay or cell type investigated. We conclude that treatment with the argon plasma jet kinpen did not display a mutagenic potential under the test conditions applied and may from this perspective be regarded as safe for the use in biomedical applications.

  5. Transport and turbulence in a magnetized argon plasma

    International Nuclear Information System (INIS)

    Three aspects of the longitudinal motion of ionized and neutral particles in a hollow cathode arc are investigated. The longitudinal plasma momentum balance of the column has been investigated, we have studied the momentum balance in relation to turbulence and we have investigated the source properties of the cathode. The study of the plasma momentum balance contains two aspects: (1) to collect experimental data on ion drift velocities and temperatures with Fabry-Perot interferometry, on electron densities and temperatures with Thomson scattering or optical spectroscopy and on neutral densities with a collisional radiative model combined with the ion energy balance; (2) to check the (classical) theory of the momentum balance with these data. The coupling between these aspects has been investigated and found to be in good agreement. (Auth.)

  6. Investigation of capacitively coupled argon plasma driven at various frequencies and validation of surface waves excitation

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Fattah, E., E-mail: essam29@hotmail.com [Physics Department, Faculty of Science, Zagazig University, Zagazig 44519 (Egypt); Physics Department, College of Science, Salman bin AbdulAziz University, Al-Kharj, P.O. 83, Al-Kharj 11942 (Saudi Arabia)

    2013-01-03

    The influence of excitation frequency (13.56–96 MHz) on the characteristics of capacitively coupled argon plasma is investigated by means of Langmuir probe and a high-voltage probe. Measurements are performed in argon pressure of 40 and 60 mTorr at a fixed discharge voltage V{sub pp}=200 V. The measured electron energy distribution function EEPFs are a bi-Maxwellian type irrespective of the driving frequency and gas pressure. The electron density and temperatures show peak over frequency range of 54–72 MHz, beyond which it decreases. The non-monotonic dependences of plasma parameters with driving frequency were interpreted in terms of excited surface wave excited at the powered electrode.

  7. 氩离子凝固术联合腹腔镜食管裂孔疝修补术加胃底折叠术治疗食管裂孔疝合并Barrett食管的疗效观察%Clinical study of argon plasma coagulation combined with laparoscopic hiatal hernia repair and fundoplication in the treatment of hiatal hernia with Barrett esophagus

    Institute of Scientific and Technical Information of China (English)

    张成; 克力木; 李义亮; 苏福增; 李慧灵; 王志; 李赞林; 艾克拜尔; 阿扎提

    2015-01-01

    Objective To investigate the clinical efficacy of argon plasma coagulation (APC) combined with laparoscopic hiatal hernia repair and fundoplication in the treatment of hiatal hernia associated with Barrett esophagus.Methods A total of 61 cases of hiatal hernias with Barrett esophagus from June 2010 to January 2014 in the Department of Minimal Invasive Surgery, Hernia and Abdominal wall Surgery, People's Hospital of Xinjiang Uyhur Autonomous Region were prospectively enrolled and were randomly allocated into two groups by computer system.Twenty-nine patients received esomeprazole 40 mg/d after APC treatment for 8 weeks (APC with medicine group).Thirty-two patients underwent laparoscopic hiatal hernia repair and Nissen fundoplication after APC treatment (APC with surgery group).All the patients were reviewed by gastroscope and pathologic examination at half a year and one year after operation respectively.Differences of disease improvement and recurrence between the two groups were evaluated.Results In APC with medicine group, the Barrett's esophagus was relieved after one or two times of APC treatment, however, gastroscope and pathology revealed recurrence of Barrett's esophagus in 7 cases at half a year, and cumulative 16 cases of recurrences were detected after one year follow-up (16/29, 55.2%).In APC with surgery group, only one patient had recurrent Barrett's esophagus at half a year, and a total of two at one year follow-up by gastroscope examination(2/32, 6.3%).Significantly low recurrence rate of Barrett's esophagus was observed in APC with surgery group compared to APC with medicine group(P<0.01).Furthermore, recurrent hiatal hernia was detected in only one case in APC with surgery group.No esophageal cancer was found in both groups during follow-up.Conclusion APC combined with laparoscopic hiatal hernia repair and fundoplication is an ideal method for patients with hiatal hernia and Barrett's esophagus.%目的 探讨氩离子凝固术(APC)联合腹

  8. Enhanced Field Emission from Argon Plasma-Treated Ultra-sharp α-Fe2O3Nanoflakes

    Directory of Open Access Journals (Sweden)

    Zhang JX

    2009-01-01

    Full Text Available Abstract Hematite nanoflakes have been synthesized by a simple heat oxide method and further treated by Argon plasmas. The effects of Argon plasma on the morphology and crystal structures of nanoflakes were investigated. Significant enhancement of field-induced electron emission from the plasma-treated nanoflakes was observed. The transmission electron microscopy investigation shows that the plasma treatment effectively removes amorphous coating and creates plenty of sub-tips at the surface of the nanoflakes, which are believed to contribute the enhancement of emission. This work suggests that plasma treatment technique could be a direct means to improve field-emission properties of nanostructures.

  9. Introduction of argon beam coagulation functionality to robotic procedures using the ABC D-Flex probe: equivalency to an existing laparoscopic instrument

    Science.gov (United States)

    Merchel, Renée. A.; Barnes, Kelli S.; Taylor, Kenneth D.

    2015-03-01

    INTRODUCTION: The ABC® D-Flex Probe utilizes argon beam coagulation (ABC) technology to achieve hemostasis during minimally invasive surgery. A handle on the probe allows for integration with robotic surgical systems and introduces ABC to the robotic toolbox. To better understand the utility of D-Flex, this study compares the performance of the D-Flex probe to an existing ABC laparoscopic probe through ex vivo tissue analysis. METHODS: Comparisons were performed to determine the effect of four parameters: ABC device, tissue type, activation duration, and distance from tissue. Ten ABC D-Flex probes were used to create 30 burn samples for each comparison. Ex vivo bovine liver and porcine muscle were used as tissue models. The area and depth of each burn was measured using a light microscope. The resulting dimensional data was used to correlate tissue effect with each variable. RESULTS: D-Flex created burns which were smaller in surface area than the laparoscopic probe at all power levels. Additionally, D-Flex achieved thermal penetration levels equivalent to the laparoscopic probe. CONCLUSION: D-Flex implements a small 7F geometry which creates a more focused beam. When used with robotic precision, quick localized superficial hemostasis can be achieved with minimal collateral damage. Additionally, D-Flex achieved equivalent thermal penetration levels at lower power and argon flow-rate settings than the laparoscopic probe.

  10. The Effect of SF6 dilution in an Argon plasma

    Science.gov (United States)

    Koirala, Sudip; Gordon, Matt

    2010-02-01

    Plasma etching is widely used in semiconductor industries. There have been extensive studies in the dilution of rare gases; however, limited studies are found in the dilution of electronegative gases. In this work, SF6 content is varied from 5% to 60% in an Ar plasma in a deep reactive ion etching system. A Langmuir probe is used to measure electron temperature (Te), electron density (ne), and electron energy distribution function (eedf). Te decreases monotonically with increasing SF6 at first, and then increases for SF6 content greater than 20%. This increase is attributed to the loss of low energy electrons in attachment and high energy electrons in excitation and ionization. As the content of SF6 is increased above 20%, the dissociation of SF6 increases and most of the low energy electrons are lost in attachment and hence the average electron temperature increases. ne decreases by an order of magnitude as the SF6 dilution is increased from 5% to 60%. eedf shows that the distribution shifts towards high energy with the increase of SF6 content, which is because of the depletion of low energy electrons. )

  11. An investigation of non-equilibrium effects in thermal argon plasmas

    International Nuclear Information System (INIS)

    This thesis deals with the study of the validity of the assumption of Local Thermal Equilibrium (LTE) in the description of the parameters of a thermal argon plasma. The aim is twofold. As the studied plasma is close to, but not completely in equilibrium, the author first attempts to obtain a simple description of the plasma in terms of an LTE model in which suitable corrections for the deviations of the plasma parameters from their LTE values is introduced. To this end the plasma parameters are studied by means of a diagnostic method in which the assumption of LTE is not made. The evaluation of the usefulness of this method is the second aim of this thesis. (Auth.)

  12. On the effect of treating poly(acrylic acid) with argon and tetrafluoromethane plasmas: Kinetics and degradation mechanism

    NARCIS (Netherlands)

    Terlingen, Johannes G.A.; Takens, Gijsbert A.J.; Gaag, van der Frederik J.; Hoffman, Allan S.; Feijen, Jan

    1994-01-01

    Poly(acrylic acid) (PAAc) films were treated with either an argon or a tetrafluoromethane (CF4) plasma and subsequently analyzed with X-ray photoelectron spectroscopy (XPS). PAAc films were decarboxylated during both types of plasma treatments. In addition, during the CF4 plasma treatment, the PAAc

  13. Pulsed microwave-driven argon plasma jet with distinctive plume patterns resonantly excited by surface plasmon polaritons

    Institute of Scientific and Technical Information of China (English)

    陈兆权; 殷志祥; 夏广庆; 洪伶俐; 胡业林; 刘明海; 胡希伟

    2015-01-01

    Atmospheric lower-power pulsed microwave argon cold plasma jets are obtained by using coaxial transmission line resonators in ambient air. The plasma jet plumes are generated at the end of a metal wire placed in the middle of the dielec-tric tubes. The electromagnetic model analyses and simulation results suggest that the discharges are excited resonantly by the enhanced electric field of surface plasmon polaritons. Moreover, for conquering the defect of atmospheric argon filamentation discharges excited by 2.45-GHz continued microwave, the distinctive patterns of the plasma jet plumes can be maintained by applying different gas flow rates of argon gas, frequencies of pulsed modulator, duty cycles of pulsed microwave, peak values of input microwave power, and even by using different materials of dielectric tubes. In addition, the emission spectrum, the plume temperature, and other plasma parameters are measured, which shows that the proposed pulsed microwave plasma jets can be adjusted for plasma biomedical applications.

  14. Coagulation parameters as a guide for fresh frozen plasma transfusion practice: A tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    Wan Haslindawani W

    2010-01-01

    Full Text Available Introduction: The appropriate use of blood and blood products means the transfusion of safe blood products only to treat a condition leading to significant morbidity or mortality, which cannot be prevented or managed effectively by other means. The safety and effectiveness of transfusion depend on the appropriate clinical use of blood and blood products. This study was conducted to review the practice of fresh frozen plasma usage (FFP for transfusion, based on the coagulation profile, requested by various departments in the Hospital Universiti Sains Malaysia (HUSM. Methodology: A retrospective review of blood bank records and coagulation profile results of the patients given FFP from October to December 2006, in Hospital USM was undertaken. The criteria set by the College of American Pathologists in 1994, were used as the guidelines. Results: One thousand six hundred and ninety-eight units of FFP were used during this study period. Only 806 (47.47% FFP units were deemed appropriate. 20.38% were based on studies without any coagulation tests prior to transfusion and 21.13% were transfused for mild prolongation of coagulation test results. About 6.41% requested FFP in the setting of normal coagulation results. Conclusion: Our results showed that a significant proportion of the FFP transfusion was not guided by the coagulation profile. We recommend that a continuous education on FFP transfusion may help to guide the appropriate request for FFP.

  15. First steps towards the reaction kinetics of HMDSO in an atmospheric pressure plasma jet in argon

    Science.gov (United States)

    Loffhagen, Detlef; Becker, Markus M.; Foest, Rüdiger; Schäfer, Jan; Sigeneger, Florian

    2014-10-01

    Hexamethyldisiloxane (HMDSO) is a silicon-organic compound which is often used as precursor for thin-film deposition by means of plasma polymerization because of its high deposition rate and low toxicity. To improve the physical understanding of the deposition processes, fundamental investigations have been performed to clarify the plasma-chemical reaction pathways of HMDSO and their effect on the composition and structure of the deposited film. The current contribution represents the main primary and secondary plasma-chemical processes and their reaction products in the effluent region of an argon plasma jet at atmospheric pressure. The importance of the different collision processes of electrons and heavy particles are discussed. Results of numerical modelling of the plasma jet and the Ar-HMDSO reaction kinetics indicate that the fragmentation of HMDSO is mainly initiated by collisions with molecular argon ions, while Penning ionization processes play a minor role for the reaction kinetics in the effluent region of the jet. The work has been supported by the German Research Foundation (DFG) under Grant LO 623/3-1.

  16. Emission Spectroscopy of OH Radical in Water-Argon Arc Plasma Jet

    Directory of Open Access Journals (Sweden)

    Alan Mašláni

    2014-01-01

    Full Text Available Emission spectra of OH radical are studied in the plasma jet generated by a plasma torch with hybrid water-argon stabilization. Plasma jet is located in a chamber with pressures 4 kPa and 10 kPa. In spite of high temperatures of produced plasma, OH spectra are observed in a large area of the jet. OH spectra are used to obtain rotational temperatures from the Boltzmann plots of resolved rotational lines. Due to line-of-sight integration of radiation, interpretation of the temperatures is not straightforward. It seems that excited OH molecules can be formed by various mechanisms, mainly in the outer parts of the jet, where thermal processes are not as dominant as in the hot central region.

  17. Comparison between modeled and experimental emission rates in ASTRAL argon plasmas.

    Science.gov (United States)

    Munoz, J.; Boivin, R.; Gardner, A.; Kamar, O.; Loch, S.; Ballance, C.

    2007-11-01

    Argon emission rate coefficients are measured in the ASTRAL helicon plasma source using a 0.33 m scanning monochromator and a CCD camera. ASTRAL produces bright intense Ar plasmas with the following parameters: ne = 10^12 - 10^13 cm-3 and Te = 2 - 10 eV, B-field ASTRAL helicon plasma source. Recent R-matrix electron-impact excitation data are combined with a new R-matrix calculation that includes pseudo-states contributions. Our collisional-radiative formalism assumes that the excited levels are in quasi-static equilibrium with the ground and metastable populations. Good to excellent agreement has been obtained by including Te and ne profiles in the modeling. The experiment-theory comparison confirms that Te is the dominant parameters in determining the emission rate coefficients in these plasmas.

  18. Investigating the Mutagenicity of a Cold Argon-Plasma Jet in an HET-MN Model

    Science.gov (United States)

    Bender, Claudia; Benkhai, Hicham; Sckell, Axel; Below, Harald; Stope, Matthias B.; Kramer, Axel

    2016-01-01

    Objective So-called cold physical plasmas for biomedical applications generate reactive oxygen and nitrogen species and the latter can trigger DNA damage at high concentrations. Therefore, the mutagenic risks of a certified atmospheric pressure argon plasma jet (kINPen MED) and its predecessor model (kINPen 09) were assessed. Methods Inner egg membranes of fertilized chicken eggs received a single treatment with either the kINPen 09 (1.5, 2.0, or 2.5 min) or the kINPen MED (3, 4, 5, or 10 min). After three days of incubation, blood smears (panoptic May-Grünwald-Giemsa stain) were performed, and 1000 erythrocytes per egg were evaluated for the presence of polychromatic and normochromic nuclear staining as well as nuclear aberrations and binucleated cells (hen’s egg test for micronuclei induction, HET-MN). At the same time, the embryo mortality was documented. For each experiment, positive controls (cyclophosphamide and methotrexate) and negative controls (NaCl-solution, argon gas) were included. Additionally, the antioxidant potential of the blood plasma was assessed by ascorbic acid oxidation assay after treatment. Results For both plasma sources, there was no evidence of genotoxicity, although at the longest plasma exposure time of 10 min the mortality of the embryos exceeded 40%. The antioxidant potential in the egg’s blood plasma was not significantly reduced immediately (p = 0.32) or 1 h (p = 0.19) post exposure to cold plasma. Conclusion The longest plasma treatment time with the kINPen MED was 5–10 fold above the recommended limit for treatment of chronic wounds in clinics. We did not find mutagenic effects for any plasma treatment time using the either kINPen 09 or kINPen MED. The data provided with the current study seem to confirm the lack of a genotoxic potential suggesting that a veterinary or clinical application of these argon plasma jets does not pose mutagenic risks. PMID:27584003

  19. Novel Diamond Films Synthesis Strategy: Methanol and Argon Atmosphere by Microwave Plasma CVD Method Without Hydrogen.

    Science.gov (United States)

    Yang, Li; Jiang, Caiyi; Guo, Shenghui; Zhang, Libo; Gao, Jiyun; Peng, Jinhui; Hu, Tu; Wang, Liang

    2016-12-01

    Diamond thin films are grown on silicon substrates by only using methanol and argon mixtures in microwave plasma chemical vapor deposition (MPCVD) reactor. It is worth mentioning that the novel strategy makes the synthesis reaction works smoothly without hydrogen atmosphere, and the substrates temperature is only 500 °C. The evidence of surface morphology and thickness under different time is obtained by characterizing the samples using scanning electron microscopy (SEM). X-ray diffractometer (XRD) spectrum reveals that the preferential orientation of (111) plane sample is obtained. The Raman spectra indicate that the dominant component of all the samples is a diamond. Moreover, the diamond phase content of the targeted films was quantitatively analyzed by X-ray photoelectron spectroscopy (XPS) method, and the surface roughness of diamond films was investigated by atomic force microscope (AFM). Meanwhile, the possible synthesis mechanism of the diamond films in methanol- and argon-mixed atmosphere was discussed. PMID:27644241

  20. Novel Diamond Films Synthesis Strategy: Methanol and Argon Atmosphere by Microwave Plasma CVD Method Without Hydrogen

    Science.gov (United States)

    Yang, Li; Jiang, Caiyi; Guo, Shenghui; Zhang, Libo; Gao, Jiyun; Peng, Jinhui; Hu, Tu; Wang, Liang

    2016-09-01

    Diamond thin films are grown on silicon substrates by only using methanol and argon mixtures in microwave plasma chemical vapor deposition (MPCVD) reactor. It is worth mentioning that the novel strategy makes the synthesis reaction works smoothly without hydrogen atmosphere, and the substrates temperature is only 500 °C. The evidence of surface morphology and thickness under different time is obtained by characterizing the samples using scanning electron microscopy (SEM). X-ray diffractometer (XRD) spectrum reveals that the preferential orientation of (111) plane sample is obtained. The Raman spectra indicate that the dominant component of all the samples is a diamond. Moreover, the diamond phase content of the targeted films was quantitatively analyzed by X-ray photoelectron spectroscopy (XPS) method, and the surface roughness of diamond films was investigated by atomic force microscope (AFM). Meanwhile, the possible synthesis mechanism of the diamond films in methanol- and argon-mixed atmosphere was discussed.

  1. Evaluation of coagulation factors in fresh frozen plasma treated with riboflavin and ultraviolet light

    Directory of Open Access Journals (Sweden)

    Antić Ana

    2012-01-01

    Full Text Available Background/Aim. Pathogen inactivation in blood products using riboflavin and ultraviolet (UV light represents a proactive approach to blood safety, not only for known infectious agents but also for new ones or not yet recognized as threats to the blood supply. This method inactivates a virus, bacteria, fungus, or protozoan pathogen from the blood product without damaging its function or shelf-life. The aim of the study was to study the influence of photoinactivation using riboflavin on the concentration of coagulation factors and coagulation inhibitors in plasma that was treated before freezing. Methods. The examination included 30 units of plasma, separated from whole blood donated by voluntary blood donors around 6 h from the moment of collection. They were treated by riboflavin (35 mL and UV rays (6.24 J/mL, 265-370 nm on Mirasol aparature (Caridian BCT Biotechnologies, USA in approximate duration of 6 min. The samples for examining were taken before (K - control units and after illumination (I - illuminated units. Results. Comparing the middle values of coagulation factors in the control and illuminated units we noticed their statistically significant decrease in illuminated units (p < 0.001, but the activity of coagulation ones was still in the reference range. The most sensitive coagulation factors to photoinactivation were FVIII, FIX and FXI (21.99%, 20.54% and 17.26% loss, respectively. Anticoagulant factors were better preseved than coagulation factors. Conclusion. Plasma separated from whole blood donation within 6 h, treated with riboflavin and UV light within 6 h from separation and frozen at temperature below -30ºC within 24 h, shows good retention of pro- and anticoagulation activity.

  2. The susceptibility of plasma coagulation factor XI to nitration and peroxynitrite action.

    Science.gov (United States)

    Ponczek, Michał Błażej

    2016-10-01

    Coagulation factor XI is present in blood plasma as the zymogen, like other serine proteases of hemostatic system, but as the only coagulation factor forms 140-160kDa homodimers. Its activation is induced by thrombin, and a positive feedback increases the generation of the extra thrombin. Experimental and clinical observations confirm protective roles of factor XI deficiencies in certain types of thromboembolic disorders. Thromboembolism still causes serious problems for modern civilization. Diseases associated with the blood coagulation system are often associated with inflammation and oxidative stress. Peroxynitrite is produced from nitric oxide and superoxide in inflammatory diseases. The aim of the current study is to evaluate effects of nitrative stress triggered by peroxynitrite on coagulation factor XI in human plasma employing biochemical and bioinformatic methods. The amidolytic assay shows increase in factor XI activity triggered by peroxynitrite. Peroxynitrite interferes factor XI by nitration and fragmentation, which is demonstrated by immunoprecipitation followed by western blotting. Nitrated factor XI is even present in control blood plasma. The results suggest possible modifications of factor XI on the molecular level. Computer simulations show tyrosine residues as targets of peroxynitrite action. The modifications induced by peroxynitrite in factor XI might be important in thrombotic disorders. PMID:27268383

  3. Frequency of cell treatment with cold microwave argon plasma is important for the final outcome

    Science.gov (United States)

    Sysolyatina, E.; Vasiliev, M.; Kurnaeva, M.; Kornienko, I.; Petrov, O.; Fortov, V.; Gintsburg, A.; Petersen, E.; Ermolaeva, S.

    2016-07-01

    The purpose of this work was to establish the influence of a regime of cold microwave argon plasma treatments on the physiological characteristics of human fibroblasts and keratinocytes. We used three regimes of plasma application: a single treatment, double treatment with a 48 h interval, and daily treatments for 3 d. Cell proliferation after plasma application was quantified in real time, and immunohistochemistry was used to establish the viability of the cells and determine changes in their physiology. It was established that the frequency of cell treatments is important for the outcome. In the samples treated with single plasma application and double plasma applications with a 48 h interval, a 42.6% and 32.0% increase was observed in the number of cells, respectively. In addition, there were no signs of deoxyribonucleic acid breaks immediately after plasma application. In contrast, plasma application increased the accumulation of cells in the active phases of the cell cycle. The activation of proliferation correlated with a decrease in the level of β-galactosidase, a senescence marker. This could be due to cell renovation after plasma application. Daily treatment decreased cell proliferation up to 29.1% in comparison with the control after 3 d.

  4. Spectra of heliumlike carbon, aluminium and argon under strongly coupled plasma

    International Nuclear Information System (INIS)

    Spectral line positions for the highly stripped helium like carbon, aluminium and argon embedded in intense plasma environments have been calculated theoretically to compare with the existing data available from laser plasma experiments. The changes in the ionization potentials for such ions have been determined and the excitation energies, oscillator strengths and transition probabilities for the transitions 1s2 1S → 1snp 1P (n 2-5) have been evaluated for the diagnostic determination of such plasmas. The ion sphere (IS) model was used for estimating the effect of strongly coupled plasma on the ions within the non-relativistic as well as the relativistic framework. Time dependent perturbation theory has been applied for obtaining the linear response properties of the ions in the non-relativistic approximation. The effects of the plasma environment on such properties of the ions under the Debye screening model with suitable cut off radii have also been considered for comparing the data with those obtained from the IS model of the plasma. These results show that the IS model seems to be a viable method for predicting the data obtained from experiments involving strongly coupled plasmas generated in laser produced Icf plasmas

  5. Spectra of heliumlike carbon, aluminium and argon under strongly coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Sil, A. [Heidelberg Univ., Theoretische Chemie (Germany); Anton, J. [Ulm Univ., Institut fur Elektrochemie (Germany); Fritzsche, S. [Gesellschaft fur Schwerionenforschung Darmstadt, Darmstadt (Germany); Mukherjee, P.K. [Indian Association for the Cultivation of Science, Jadavpur, Kolkata (India); Ramakrishna Mission Vivekananda Univ., West Bengal (India); Fricke, B. [Kassel Univ., Institut fur Physik (Germany)

    2009-12-15

    Spectral line positions for the highly stripped helium like carbon, aluminium and argon embedded in intense plasma environments have been calculated theoretically to compare with the existing data available from laser plasma experiments. The changes in the ionization potentials for such ions have been determined and the excitation energies, oscillator strengths and transition probabilities for the transitions 1s{sup 2} 1S -> 1snp {sup 1}P (n 2-5) have been evaluated for the diagnostic determination of such plasmas. The ion sphere (IS) model was used for estimating the effect of strongly coupled plasma on the ions within the non-relativistic as well as the relativistic framework. Time dependent perturbation theory has been applied for obtaining the linear response properties of the ions in the non-relativistic approximation. The effects of the plasma environment on such properties of the ions under the Debye screening model with suitable cut off radii have also been considered for comparing the data with those obtained from the IS model of the plasma. These results show that the IS model seems to be a viable method for predicting the data obtained from experiments involving strongly coupled plasmas generated in laser produced Icf plasmas

  6. Effect of Argon Plasma Treatment Variables on Wettability and Antibacterial Properties of Polyester Fabrics

    Science.gov (United States)

    Senthilkumar, Pandurangan; Karthik, Thangavelu

    2016-04-01

    In this research work, the effect of argon plasma treatment variables on the comfort and antibacterial properties of polyester fabric has been investigated. The SEM micrographs and FTIR analysis confirms the modification of fabric surface. The Box-Behnken design was used for the optimization of plasma process variables and to evaluate the effects and interactions of the process variables, i.e. operating power, treatment time and distance between the electrodes on the characteristics of polyester fabrics. The optimum conditions of operating power 600 W, treatment time 30 s, and the distance between the electrodes of 2.8 mm was arrived using numerical prediction tool in Design-Expert software. The plasma treated polyester fabrics showed better fabric characteristics particularly in terms of water vapour permeability, wickability and antibacterial activity compared to untreated fabrics, which confirms that the modified structure of polyester fabric.

  7. Two-dimensional ion velocity distribution functions in inductively coupled argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Zimmerman, David C [Optical Sciences Company, Anaheim, CA 92806 (United States); McWilliams, Roger [Department of Physics and Astronomy, University of California at Irvine, Irvine, CA 92697 (United States); Edrich, David A [Scientific Applications and Research Associates Inc., Cypress, CA 90630 (United States)

    2005-08-01

    Two-dimensional ion velocity distribution functions (IVDFs) of argon plasmas have been measured with optical tomography via laser-induced fluorescence (LIF). An inductive radio-frequency (RF) coil created the plasmas, and IVDFs were measured versus RF frequency, gas pressure and location (bulk plasma or presheath of a plate). Typical gas pressure was 0.3-0.4 mTorr, RF power 25 W and magnetic field 130 G. Effective perpendicular ion temperature decreased with increasing RF frequency, and changed little with pressure. Optical tomography reveals features of the presheath IVDF that cannot be deduced from LIF scans parallel and perpendicular to the plate alone. Progress also has been made toward performing optical tomography on a commercial ion beam source (Veeco/Ion Tech 3 cm RF Ion Source, Model no. 201). In particular, it has been discovered that the beam energy fluctuates in a range of about 20 eV over the timescale of a few minutes.

  8. Waves generated in the vicinity of an argon plasma gun in the ionosphere

    Science.gov (United States)

    Cahill, L. J., Jr.; Arnoldy, R. L.; Lysak, R. L.; Peria, W.; Lynch, K. A.

    1993-01-01

    Wave and particle observations were made in the close vicinity of an argon plasma gun carned to over 600 km altitude on a sounding rocket. The gun was carned on a subpayload, separated from the main payload early in the flight. Twelve-second argon ion ejections were energized alternately with a peak energy of 100 or 200 eV. They produced waves, with multiple harmonics, in the range of ion cyclotron waves, 10 to 1000 Hz at rocket altitudes. Many of these waves could not be identified as corresponding to the cyclotron frequencies of any of the ions, argon or ambient, known to be present. In addition, the wave frequencies were observed to rise and fall and to change abruptly during a 12-s gun operation. The wave amplitudes, near a few hundred Hertz, were of the order of O. 1 V/m. Some of the waves may be ion-ion hybrid waves. Changes in ion populations were observed at the main payload and at the subpayload during gun operations. A gun-related, field-aligned, electron population also appeared.

  9. Particle-in-Cell Modeling of Magnetized Argon Plasma Flow Through Small Mechanical Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Adam B. Sefkow and Samuel A. Cohen

    2009-04-09

    Motivated by observations of supersonic argon-ion flow generated by linear helicon-heated plasma devices, a three-dimensional particle-in-cell (PIC) code is used to study whether stationary electrostatic layers form near mechanical apertures intersecting the flow of magnetized plasma. By self-consistently evaluating the temporal evolution of the plasma in the vicinity of the aperture, the PIC simulations characterize the roles of the imposed aperture and applied magnetic field on ion acceleration. The PIC model includes ionization of a background neutral-argon population by thermal and superthermal electrons, the latter found upstream of the aperture. Near the aperture, a transition from a collisional to a collisionless regime occurs. Perturbations of density and potential, with mm wavelengths and consistent with ion acoustic waves, propagate axially. An ion acceleration region of length ~ 200-300 λD,e forms at the location of the aperture and is found to be an electrostatic double layer, with axially-separated regions of net positive and negative charge. Reducing the aperture diameter or increasing its length increases the double layer strength.

  10. Investigation of forbidden transitions in argon ions. [in laboratory plasma for solar corona simulation

    Science.gov (United States)

    Jalufka, N. W.

    1976-01-01

    An attempt has been made to observe the visible forbidden argon coronal lines at 553.6 nm (Ar X), 691.7 nm (Ar XI), 847.6 nm (Ar XIII), and 441.2 nm (Ar XIV) in a deuterium-argon plasma produced in a large theta pinch. The electron temperature (250 eV) and the electron density (5 by 10 to the 16th power per cu cm) were measured by Thomson scattering of ruby laser radiation. This temperature is adequate to produce ionization stages up to Ar XIV, as was verified by photographic observation of Ar XIV lines. No line corresponding to the coronal lines was observed from the high-temperature plasma, but lines with wavelengths very nearly identical to those of two of the forbidden transitions were observed; these lines were due to allowed transitions of Ar II in a cooler portion of the plasma. Calculation of rate coefficients in the Coulomb-Born approximation shows that for laboratory experiments, electron collisions are much more important than radiative decay in depopulating the upper state of the forbidden lines.

  11. Development of a microplate coagulation assay for Factor V in human plasma

    Directory of Open Access Journals (Sweden)

    Samis John A

    2011-06-01

    Full Text Available Abstract Background Factor V (FV in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. Methods The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. Results The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC, the FV 1-stage, 2-stage (With activation by thrombin, and total (2-stage activity - 1-stage activity activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP. The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. Conclusions The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in

  12. Effect of neutral gas heating in argon radio frequency inductively coupled plasma

    International Nuclear Information System (INIS)

    Heating of neutral gas in inductively coupled plasma (ICP) is known to result in neutral gas depletion. In this work, this effect is considered in the simulation of the magnetic field distribution of a 13.56 MHz planar coil ICP. Measured electron temperatures and densities at argon pressures of 0.03, 0.07 and 0.2 mbar were used in the simulation whilst neutral gas temperatures were heuristically fitted. The simulated results showed reasonable agreement with the measured magnetic field profile. (author)

  13. Decay of femtosecond laser-induced plasma filaments in air, nitrogen, and argon for atmospheric and subatmospheric pressures.

    Science.gov (United States)

    Aleksandrov, N L; Bodrov, S B; Tsarev, M V; Murzanev, A A; Sergeev, Yu A; Malkov, Yu A; Stepanov, A N

    2016-07-01

    The temporal evolution of a plasma channel at the trail of a self-guided femtosecond laser pulse was studied experimentally and theoretically in air, nitrogen (with an admixture of ∼3% O_{2}), and argon in a wide range of gas pressures (from 2 to 760 Torr). Measurements by means of transverse optical interferometry and pulsed terahertz scattering techniques showed that plasma density in air and nitrogen at atmospheric pressure reduces by an order of magnitude within 3-4 ns and that the decay rate decreases with decreasing pressure. The argon plasma did not decay within several nanoseconds for pressures of 50-760 Torr. We extended our theoretical model previously applied for atmospheric pressure air plasma to explain the plasma decay in the gases under study and to show that allowance for plasma channel expansion affects plasma decay at low pressures. PMID:27575227

  14. Thermalization of electrons in decaying extreme ultraviolet photons induced low pressure argon plasma

    Science.gov (United States)

    Beckers, J.; van der Horst, R. M.; Osorio, E. A.; Kroesen, G. M. W.; Banine, V. Y.

    2016-06-01

    We monitored—in the pressure range: 0.5–15 Pa—the electron temperature in decaying plasmas induced in argon gas by pulsed irradiation with extreme ultraviolet (EUV) photons with wavelengths closely around 13.5 nm. For this purpose, temporal measurements of the space-averaged and electric field weighted electron density after pulsed EUV irradiation are combined with an ambipolar diffusion model of the plasma. Results demonstrate that electrons are thermalized to room temperature before the plasma has fully expanded to the chamber walls for pressures of 3 Pa and higher. At pressures below 3 Pa, the electron temperature was found to be up to 0.1 eV above room temperature which is explained by the fact that plasma expansion is too quick for the electrons to fully thermalize. The comparison between plasma expansion duration towards a surface, plasma decay at a surface and time needed for thermalization and cooling of electrons is essential for designers of EUV lithography tools and EUV sources since the temperature of electrons dictates many fundamental physical processes.

  15. Characteristics of a long and stable filamentary argon plasma jet generated in ambient atmosphere

    Science.gov (United States)

    Teodorescu, M.; Bazavan, M.; Ionita, E. R.; Dinescu, G.

    2015-04-01

    We present a study of a long (up to 60 mm) and thin (600 μm) plasma jet generated at 13.56 MHz in argon expanding in an open atmosphere from inside of a thin glass tube. The discharge is operated with one annular external electrode on the tube, in the absence of any grounded electrode in the discharge proximity. The study comprises image, spectral and electrical measurements, aiming to define and understand the operating domains of this plasma jet source. Two plasma zones were identified, which coexist: a long filament accompanied by a diffuse discharge. The coexistence of these plasma zones was studied in the power-mass flow rate parameter space. An electric model is proposed, considering the jet as a radiating antenna, which allows the determination of the main electrical parameters like capacitance, resistance and active RF power dissipated in the discharge. The specific zones on the I-V characteristics were assigned to the operating domains observed visually. The spectral emission of plasma has been used to characterize the jet in respect to the gas temperature, excitation temperature and plasma density.

  16. Surface-mediated molecular events in material-induced blood-plasma coagulation

    Science.gov (United States)

    Chatterjee, Kaushik

    Coagulation and thrombosis persist as major impediments associated with the use of blood-contacting medical devices. We are investigating the molecular mechanism underlying material-induced blood-plasma coagulation focusing on the role of the surface as a step towards prospective development of improved hemocompatible biomaterials. A classic observation in hematology is that blood/blood-plasma in contact with clean glass surface clots faster than when in contact with many plastic surfaces. The traditional biochemical theory explaining the underlying molecular mechanism suggests that hydrophilic surfaces, like that of glass, are specific activators of the coagulation cascade because of the negatively-charged groups on the surface. Hydrophobic surfaces are poor procoagulants or essentially "benign" because they lack anionic groups. Further, these negatively-charged surfaces are believed to not only activate blood factor XII (FXII), the key protein in contact activation, but also play a cofactor role in the amplification and propagation reactions that ultimately lead to clot formation. In sharp contrast to the traditional theory, our investigations indicate a need for a paradigm shift in the proposed sequence of contact activation events to incorporate the role of protein adsorption at the material surfaces. These studies have lead to the central hypothesis for this work proposing that protein adsorption to hydrophobic surfaces attenuates the contact activation reactions so that poorly-adsorbent hydrophilic surfaces appear to be stronger procoagulants relative to hydrophobic surfaces. Our preliminary studies measuring the plasma coagulation response of activated FXII (FXIIa) on different model surfaces suggested that the material did not play a cofactor role in the processing of this enzyme dose through the coagulation pathway. Therefore, we focused our efforts on studying the mechanism of initial production of enzyme at the procoagulant surface. Calculations for the

  17. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat [Department of Physics, Facuty of Science, Chulalongkorn University, Bangkok (Thailand); Plasma Technology and Nuclear Fusion Research Unit, Chulalongkorn University, Bangkok (Thailand)

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) can be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.

  18. Long-term spatio-temporal evolution of the dust distribution in dusty argon rf plasmas

    Science.gov (United States)

    Killer, Carsten; Greiner, Franko; Groth, Sebastian; Tadsen, Benjamin; Melzer, André

    2016-10-01

    The 3D dust distribution in dense dust clouds confined in argon rf plasmas is measured by a computed tomography (CT) technique based on the extinction of visible light. On the one hand, clouds of micron-sized particles were created by injecting standardized plastic particles into the plasma. On the other hand, sub-micron sized dust with well-defined properties is grown in situ in an argon acetylene mixture. Once created, both kinds of dust clouds decay in the course of minutes to hours. This decay is monitored by CT measurements. It is revealed that micro-dust clouds feature a drastic change of the dust distribution due to a size reduction of the dust. Dust clouds of sub-micron particles, in contrast, show a strong variation of the overall dust density while the relative dust distribution remains nearly unchanged. The evolution of the overall dust density is subject to two effects: the loss of particles due to an imperfect confinement and the reduction of the dust size via etching.

  19. Generation of uniform atmospheric pressure argon glow plasma by dielectric barrier discharge

    Indian Academy of Sciences (India)

    Raju Bhai Tyata; Deepak Prasad Subedi; Rajendra Shrestha; Chiow San Wong

    2013-03-01

    In this paper, atmospheric pressure glow discharges (APGD) in argon generated in parallel plate dielectric barrier discharge system is investigated by means of electrical and optical measurements. Using a high voltage (0–20 kV) power supply operating at 10–30 kHz, homogeneous and steady APGD has been observed between the electrodes with gap spacing from 0.5 mm to 2 mm and with a dielectric barrier of thickness 2 mm while argon gas is fed at a controlled flow rate of 11/min. The electron temperature and electron density of the plasma are determined by means of optical emission spectroscopy. Our results show that the electron density of the discharge obtained is of the order of 1016 cm-3 while the electron temperature is estimated to be 0.65 eV. The important result is that electron density determined from the line intensity ratio method and stark broadening method are in very good agreement. The Lissajous figure is used to estimate the energy deposited to the glow discharge. It is found that the energy deposited to the discharge is in the range of 20 to 25 $\\$J with a discharge voltage of 1.85 kV. The energy deposited to the discharge is observed to be higher at smaller gas spacing. The glow discharge plasma is tested to be effective in reducing the hydrophobicity of polyethylene film significantly.

  20. Theoretical investigation of the effect of hydrogen addition on the formation and properties of soliton in direct current argon plasma

    International Nuclear Information System (INIS)

    In this study the effect of hydrogen addition on the formation and properties of soliton in direct-current (DC) argon plasma is theoretically investigated. By coupling fluid equations with Poisons equation for such multi-component plasma, the Mach number and amplitude of the soliton are determined following pseudo potential method. Addition of hydrogen in argon discharge leads to the decrease of electron, Ar+ ion density while a reverse trend was observed for ArH+ and hydrogen like ions. It was found that presence of hydrogen like ions in argon plasma affects the formation of soliton with its amplitude significantly decreases as concentration of hydrogen increases. On the other hand, increase in ion to electron temperature ratios of the lighter ions in the discharge also has a significant influence on the amplitude and formation of soliton. The inverse relation between solitons width and amplitude is found to be consistent for the entire range of study

  1. Generation of Cold Argon Plasma Jet at the End of Flexible Plastic Tube

    CERN Document Server

    Kostov, Konstantin G; Prysiazhnyi, Vadym

    2014-01-01

    This brief communication reports a new method for generation of cold atmospheric pressure plasma jet at the downstream end of a flexible plastic tube. The device consists of a small chamber where dielectric barrier discharge (DBD) is ignited in Argon. The discharge is driven by a conventional low frequency AC power supply. The exit of DBD reactor is connected to a commercial flexible plastic tube (up to 4 meters long) with a thin floating Cu wire inside. Under certain conditions an Ar plasma jet can be extracted from the downstream tube end and there is no discharge inside the plastic tube. The jet obtained by this method is cold enough to be put in direct contact with human skin without electric shock and can be used for medical treatment and decontamination.

  2. A comparison among optical emission spectroscopic methods of determining electron temperature in low pressure argon plasmas

    Institute of Scientific and Technical Information of China (English)

    Niu Tian-Ye; Cao Jin-Xiang; Liu Lei; Liu Jin-Ying; Wang Yan; Wang Liang

    2007-01-01

    In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas.

  3. Study of collisional and radiatif processes for atmospheric pressure argon plasma in stationary state and quenching

    International Nuclear Information System (INIS)

    The positive column of a wall-stabilized arc burning in argon at atmospheric pressure is studied. In the first part, experimental values of electron and atom number densities are presented. They have been obtained in stationary state and during the arc decay by means of spectroscopy and two wavelengths laser interferometry measurements. The theoretical study has been developed with a collisional-radiative model coupled with the electron energy balance. Electron-ion recombination and ionization coefficients have been calculated solving rate equations. Then the model has been adapted for studying a stationary plasma and the calculated results are in good agreement with the experimental values. The theoretical study of the plasma decay has allowed us to determine the influence of recombination, ionization, diffusion and convection in the evolution of densities and temperatures. Temporal variations of the difference between electron temperature and gas temperature have been explained by analysing the electron energy balance

  4. Measurement of factor v activity in human plasma using a microplate coagulation assay.

    Science.gov (United States)

    Tilley, Derek; Levit, Irina; Samis, John A

    2012-09-09

    In response to injury, blood coagulation is activated and results in generation of the clotting protease, thrombin. Thrombin cleaves fibrinogen to fibrin which forms an insoluble clot that stops hemorrhage. Factor V (FV) in its activated form, FVa, is a critical cofactor for the protease FXa and accelerator of thrombin generation during fibrin clot formation as part of prothrombinase (1, 2). Manual FV assays have been described (3, 4), but they are time consuming and subjective. Automated FV assays have been reported (5-7), but the analyzer and reagents are expensive and generally provide only the clot time, not the rate and extent of fibrin formation. The microplate platform is preferred for measuring enzyme-catalyzed events because of convenience, time, cost, small volume, continuous monitoring, and high-throughput (8, 9). Microplate assays have been reported for clot lysis (10), platelet aggregation (11), and coagulation Factors (12), but not for FV activity in human plasma. The goal of the method was to develop a microplate assay that measures FV activity during fibrin formation in human plasma. This novel microplate method outlines a simple, inexpensive, and rapid assay of FV activity in human plasma. The assay utilizes a kinetic microplate reader to monitor the absorbance change at 405 nm during fibrin formation in human plasma (Figure 1) (13). The assay accurately measures the time, initial rate, and extent of fibrin clot formation. It requires only μl quantities of plasma, is complete in 6 min, has high-throughput, is sensitive to 24-80 pM FV, and measures the amount of unintentionally activated (1-stage activity) and thrombin-activated FV (2-stage activity) to obtain a complete assessment of its total functional activity (2-stage activity - 1-stage activity). Disseminated intravascular coagulation (DIC) is an acquired coagulopathy that most often develops from pre-existing infections (14). DIC is associated with a poor prognosis and increases mortality

  5. Laser scattering diagnostics of an argon atmospheric-pressure plasma jet in contact with vaporized water

    Science.gov (United States)

    Seo, B. H.; Kim, J. H.; You, S. J.; Seong, D. J.

    2015-12-01

    The radial profiles of the electron density, electron temperature, and molecular rotational temperature are investigated in an argon atmospheric-pressure plasma jet in contact with vaporized water, which is driven by a 13.56 MHz radio frequency by means of the Thomson and Raman laser scattering methods. There is a distinct difference in the radial profiles of the plasma parameters between plasmas in contact with water and those without water contact. In the case of plasmas without vaporized water contact, all the parameters have a single-peak distribution with maximum values at the center of the discharge. In the case of plasmas in contact with vaporized water, all parameters have double-peak distributions; a neighboring peak appears beside the main peak. The new peak may have originated from the ripple of the water surface, which works as a cathode, and the peak of the ripple offers a sharp curvature point, playing the role of a pin. Our experimental results and the underlying physics are described in detail.

  6. Refreezing previously thawed fresh-frozen plasma. Stability of coagulation factors V and VIII:C.

    Science.gov (United States)

    Dzik, W H; Riibner, M A; Linehan, S K

    1989-09-01

    With the growth in autologous blood programs and the increased scrutiny of the indications for transfusion of fresh-frozen plasma (FFP), an increase has been seen in the number of occasions on which FFP was requested and thawed but then not transfused. The coagulation properties of FFP units that were refrozen and then rethawed were therefore studied. Fifty-eight units of plasma were studied, with each experimental unit of FFP paired with an identical control unit. Experimental units were frozen, stored at -65 degrees C, thawed, stored at 1 to 6 degrees C for various periods of time up to 24 hours, and then refrozen, stored at -65 degrees C, rethawed, and stored again in the refrigerator for up to 24 hours. Control units were frozen once at the time the experimental units were first frozen and thawed once at the time of the second thaw of the experimental units. Aliquots of plasma were sampled periodically and were later batch-tested for prothrombin time (PT), activated partial thromboplastin time (aPTT), and factor V and VIII:C activity. The results of coagulation testing of the twice-frozen plasmas were always within the normal range. There was a slight but statistically valid prolongation of the PT and aPTT and a decrease in the factor V and VIII:C levels for twice-frozen plasma compared with control plasma. The greatest decline occurred in the level of factor VIII:C. The measured deterioration in coagulation of twice-frozen FFP is unlikely to be of clinical importance. Refreezing FFP may eventually prove useful for rare donor, autologous, and massive transfusion programs.

  7. ULTRAVIOLET INDUCED MOTION OF A FLUORESCENT DUST CLOUD IN AN ARGON DIRECT CURRENT GLOW DISCHARGE PLASMA

    Energy Technology Data Exchange (ETDEWEB)

    Hvasta, M.G.; and Zwicker, A.

    2008-01-01

    Dusty plasmas consist of electrons, ions, neutrals and nm-μm sized particles commonly referred to as dust. In man-made plasmas this dust may represent impurities in a tokamak or plasma etching processing. In astrophysical plasmas this dust forms structures such as planetary rings and comet tails. To study dusty plasma dynamics an experiment was designed in which a 3:1 silica (<5 μm diameter) and fl uorescent dust mixture was added to an argon DC glow discharge plasma and exposed to UV radiation. This fl uorescent lighting technique offers an advantage over laser scattering (which only allows two-dimensional slices of the cloud to be observed) and is simpler than scanning mirror techniques or particle image velocimetry. Under typical parameters (P=150 mTorr, V anode= 100 V, Vcathode= -400 V, Itotal < 2mA) when the cloud is exposed to the UV light (100W, λ = 365 nm) the mixture fl uoresces, moves ~2mm towards the light source and begins rotating in a clockwise manner (as seen from the cathode). By calibrating a UV lamp and adjusting the relative intensity of the UV with a variable transformer it was found that both translational and rotational velocities are a function of UV intensity. Additionally, it was determined that bulk cloud rotation is not seen when the dust tray is not grounded while bulk translation is. This ongoing experiment represents a novel way to control contamination in man-made plasmas and a path to a better understanding of UV-bathed plasma systems in space..

  8. Two-dimensional profile measurement of plasma parameters in radio frequency-driven argon atmospheric pressure plasma jet

    International Nuclear Information System (INIS)

    The two-dimensional profiles of the electron density, electron temperature, neutral translational temperature, and molecular rotational temperature are investigated in an argon atmospheric pressure plasma jet, which is driven by the radio frequency of 13.56 MHz by means of the laser scattering methods of Thomson, Rayleigh, and Raman. All measured parameters have maximum values at the center of the discharge and decrease toward the plasma edge. The results for the electron temperature profile are contrary to the results for the microwave-driven plasma. From our experimental results, the profiles of the plasma parameters arise from the radial contraction of plasmas and the time averaged profile of the electric field, which is obtained by a microwave simulation performed under identical conditions to the plasma jet. In the case of the neutral temperature, a higher translational temperature than the rotational temperature is measured, and its discrepancy is tentatively explained in terms of the low ion-neutral charge exchange rate and the additional degrees of freedom of the molecules. The description of our experimental results and the underlying physics are addressed in detail

  9. Two-dimensional profile measurement of plasma parameters in radio frequency-driven argon atmospheric pressure plasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Seo, B. H.; Kim, J. H., E-mail: jhkim86@kriss.re.kr [Center for Vacuum Technology, Korea Research Institute of Standards and Science, Daejeon 305-340 (Korea, Republic of); Kim, D. W. [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-338 (Korea, Republic of); You, S. J., E-mail: sjyou@cnu.ac.kr [Department of Physics, Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2015-09-15

    The two-dimensional profiles of the electron density, electron temperature, neutral translational temperature, and molecular rotational temperature are investigated in an argon atmospheric pressure plasma jet, which is driven by the radio frequency of 13.56 MHz by means of the laser scattering methods of Thomson, Rayleigh, and Raman. All measured parameters have maximum values at the center of the discharge and decrease toward the plasma edge. The results for the electron temperature profile are contrary to the results for the microwave-driven plasma. From our experimental results, the profiles of the plasma parameters arise from the radial contraction of plasmas and the time averaged profile of the electric field, which is obtained by a microwave simulation performed under identical conditions to the plasma jet. In the case of the neutral temperature, a higher translational temperature than the rotational temperature is measured, and its discrepancy is tentatively explained in terms of the low ion-neutral charge exchange rate and the additional degrees of freedom of the molecules. The description of our experimental results and the underlying physics are addressed in detail.

  10. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    Science.gov (United States)

    Van Deynse, A.; Cools, P.; Leys, C.; De Geyter, N.; Morent, R.

    2015-02-01

    Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1-1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the discharge power, the concentrations of all oxygen containing groups such as Csbnd O, Cdbnd O and Osbnd Cdbnd O increase. Increasing the flow rate up to 1.25 slm results mainly in an increase in Osbnd Cdbnd O groups. However, from a flow rate of 1.25 slm on, the concentration of all oxygen groups again decreases. Based on these results, the appropriate settings for an efficient plasma treatment can easily be selected.

  11. Morphology and characteristics of laser-induced aluminum plasma in argon and in air: A comparative study

    Science.gov (United States)

    Bai, Xueshi; Cao, Fan; Motto-Ros, Vincent; Ma, Qianli; Chen, Yanping; Yu, Jin

    2015-11-01

    In laser-induced breakdown spectroscopy (LIBS), ablation takes place in general in an ambient gas of the atmospheric pressure, often in air but also in noble gas such as argon or helium. The use of noble gas is known to significantly improve the performance of the technique. We investigate in this work the morphology and the characteristics of induced plasma in argon and in air. The purpose is to understand the mechanism of the analytical performance improvement by the use of argon ambient with respective to air ambient and the dependence on the other experimental parameters such as the laser fluence. The observation of plasma morphology in different ambient gases provides also information for better design of the detection system which optimizes the signal collection according to the used ambient gases. More specifically, the expansion of the plasma induced on an aluminum target with nanosecond infrared (1064 nm) laser pulse in two ambient gases, argon and the atmospheric air, has been studied with spectroscopic imaging at short delays and with emission spectroscopy at longer delays. With relatively low ablation laser fluence (65 J/cm2), similar morphologies have been observed in argon and in air over the early stage of plasma expansion, while diagnostics at longer delay shows stronger emission, higher electron density and temperature for plasma induced in argon. With higher ablation laser fluence (160 J/cm2) however, different expansion behaviors have been observed, with a stagnating aluminum vapor near the target surface in air while a propagating plume away from the target in argon. The craters left on the target surface show as well corresponding difference: in air, the crater is very shallow with a target surface chaotically affected by the laser pulse, indicating an effective re-deposition of the ablated material back to the crater; while in Ar a deeper crater is observed, indicating an efficient mass removal by laser ablation. At longer delays, a brighter

  12. Simulation of DBD plasma actuators, and nanoparticle-plasma interactions in argon-hydrogen CCP RF discharges

    Science.gov (United States)

    Mamunuru, Meenakshi

    The focus of this work is modeling and simulation of low temperature plasma discharges (LTPs). The first part of the thesis consists of the study of dielectric barrier (DBD) plasma actuators. Use of DBD plasma actuators on airfoil surfaces is a promising method for increasing airfoil efficiency. Actuators produce a surface discharge that causes time averaged thrust in the neutral gas. The thrust modifies the boundary layer properties of the flow and prevents the occurrence of separation bubbles. In simulating the working of an actuator, the focus is on the spatial characteristics of the thrust produced by the discharge over very short time and space scales. The results provide an understanding of the causes of thrust, and the basic principles behind the actuator operation. The second part of this work focusses on low pressure plasma discharges used for silicon nanoparticle synthesis. When reactive semiconductor precursor gases are passed through capacitively coupled plasma (CCP) radio frequency (RF) reactors, nano sized particles are formed. When the reactors are operated at high enough powers, a very high fraction of the nanoparticles are crystallized in the chamber. Nanoparticle crystallization in plasma is a very complex process and not yet fully understood. It can be inferred from experiments that bulk and surface processes initiated due to energetic ion impaction of the nanoparticles are responsible for reordering of silicon atoms, causing crystallization. Therefore, study of plasma-particle interactions is the first step towards understanding how particles are crystallized. The specific focus of this work is to investigate the experimental evidence that hydrogen gas presence in argon discharges used for silicon nanocrystal synthesis, leads to a superior quality of nanocrystals. Influence of hydrogen gas on plasma composition and discharge characteristics is studied. Via Monte Carlo simulation, distribution of ion energy impacting particles surface is studied

  13. The influence of the EUV spectrum on plasma induced by EUV radiation in argon and hydrogen gas

    Science.gov (United States)

    van der Horst, R. M.; Osorio, E. A.; Banine, V. Y.; Beckers, J.

    2016-02-01

    Plasmas induced by EUV radiation are scarcely investigated, although they are unique since they are created without any discharge. These plasmas are also of interest from an applicational point of view, since they are related to the lifetime of optics in EUV lithography tools. In order to assess this impact, it is essential to characterize and understand EUV-induced plasma. In this contribution the influence of the background gas (argon and hydrogen) in the lithography tool and the spectrum of the illumination source on the electron density of EUV-induced plasma is investigated using microwave cavity resonance spectroscopy. The experimental results showed that out-of-band radiation (>20 nm) is the main contributor to EUV-induced plasma in both argon and hydrogen. In hydrogen, this contribution is relatively more important than in argon due to the stronger wavelength dependence of the photoionization cross section of hydrogen than of argon. Furthermore, the production of electrons by out-of-band radiation lasts longer than the production by in-band radiation (10-20 nm) due to the longer temporal width of out-of-band radiation. Finally, the obtained results correspond reasonably well with estimates from a simplified absorption model.

  14. Experimental behaviour of a argon plasma, which is passed by a high current intensity, with different magnetic field configurations; Comportamiento experimental de un plasma de argon en diferentes configuraciones de campo magnetico y a elevadas corrientes

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, J.

    1964-07-01

    In a lineal discharge, the longitudinal and azimuthal magnetic fields produced by the current through the tube and the returning conductors, which have 4 different forms, are determined with a magnetic probe, which has a radial and longitudinal displacement. The plasma is produced discharging a 135{mu}F and 9 KV capacitor bank through Argon at 10{sup -}1 Torr. (Author) 5 refs.

  15. Temporally and spatially resolved characterization of microwave induced argon plasmas: Experiment and modeling

    Science.gov (United States)

    Baeva, M.; Andrasch, M.; Ehlbeck, J.; Loffhagen, D.; Weltmann, K.-D.

    2014-04-01

    Experiments and modeling of the plasma-microwave interaction have been performed in a coaxial microwave plasma source at a field frequency of 2.45 GHz generating argon plasmas at pressures of 20 and 40 millibars and a ratio of flow rate to pressure of 0.125 sccm/Pa. The incident microwave power between 100 W and 300 W is supplied in a regime of a pulse-width modulation with cycle duration of 110 ms and a power-on time of 23 ms. The experiments are based on heterodyne reflectometry and microwave interferometry at 45.75 GHz. They provide the temporal behaviour of the complex reflection coefficient, the microwave power in the plasma, as well as the electron density in the afterglow zone of the discharge. The self-consistent spatially two-dimensional and time-dependent modeling complements the analysis of the plasma-microwave interaction delivering the plasma and electromagnetic field parameters. The consolidating experimental observations and model predictions allow further characterizing the plasma source. The generated plasma has a core occupying the region close to the end of the inner electrode, where maximum electron densities above 1020 m-3 and electron temperatures of about 1 eV are observed. Due to a longer outer electrode of the coaxial structure, the plasma region is extended and fills the volume comprised by the outer electrode. The electron density reaches values of the order of 1019 m-3. The heating of the gas occurs in its great part due to elastic collisions with the plasma electrons. However, the contribution of the convective heating is important especially in the extended plasma region, where the gas temperature reaches its maximum values up to approximately 1400 K. The temporally and spatially resolved modeling enables a thorough investigation of the plasma-microwave interaction which clearly shows that the power in-coupling occurs in the region of the highest electron density during the early stage of the discharge. In the steady state phase

  16. On the Role of Metastable Argon in Cold Atmospheric Pressure Plasma Jets with Shielding Gas Device

    Science.gov (United States)

    Schmidt-Bleker, Ansgar; Winter, Jorn; Sousa, Joao Santos; Puech, Vincent; Weltmann, Klaus-Dieter; Reuter, Stephan; ZIK plasmatis at the INP Greifswald e. V. Team; Laboratoire de Physique des Gaz et des Plasmas (LPGP), CNRS; Université Paris-Sud Team

    2014-10-01

    Shielding gas devices are a valuable tool for controlling the reactive species output of Cold Atmospheric Pressure Plasma (CAPP) Jets for biomedical applications. In this work we investigate the effect of different shielding gas compositions using a CAPP jet (kinpen) operated with argon. As shielding gas various mixtures of N2 and O2 are used. Metastable argon (Ar*) has been quantified using laser absorption spectroscopy and was identified as an important energy carrier in the CAPP jets effluent. The Ar* excitation dynamics was studied using phase resolve optical emission spectroscopy. Based on these findings a kinetic model for the gas phase chemistry has been developed that uses the Ar* density and dynamics as input and yields densities of O3, NO2, HNO2, HNO3, N2O5, H2O2 and N2O produced by the CAPP jet for different shielding gas compositions. The results are in good agreement with Fourier-Transform Infrared Spectroscopy measurements on these species. Authors gratefully acknowledge the funding by German Federal Ministry of Education a Research (BMBF) (Grant # 03Z2DN12).

  17. Study of a contracted glow in low-frequency plasma-jet discharges operating with argon

    Energy Technology Data Exchange (ETDEWEB)

    Minotti, F.; Giuliani, L.; Xaubet, M.; Grondona, D. [Departamento de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, C1428EHA, Buenos Aires, Argentina and Instituto de Física del Plasma (INFIP), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad de Buenos Aires - UBA, C1428EHA, Buenos Aires (Argentina)

    2015-11-15

    In this work, we present an experimental and theoretical study of a low frequency, atmospheric plasma-jet discharge in argon. The discharge has the characteristics of a contracted glow with a current channel of submillimeter diameter and a relatively high voltage cathode layer. In order to interpret the measurements, we consider the separate modeling of each region of the discharge: main channel and cathode layer, which must then be properly matched together. The main current channel was modeled, extending a previous work, as similar to an arc in which joule heating is balanced by lateral heat conduction, without thermal equilibrium between electrons and heavy species. The cathode layer model, on the other hand, includes the emission of secondary electrons by ion impact and by additional mechanisms, of which we considered emission due to collision of atoms excited at metastable levels, and field-enhanced thermionic emission (Schottky effect). The comparison of model and experiment indicates that the discharge can be effectively sustained in its contracted form by the secondary electrons emitted by collision of excited argon atoms, whereas thermionic emission is by far insufficient to provide the necessary electrons.

  18. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    Energy Technology Data Exchange (ETDEWEB)

    Van Deynse, A., E-mail: Annick.VanDeynse@ugent.be [Department Industrial Technology and Construction, Faculty of Engineering & Architecture, Ghent University, Valentin Vaerwyckweg 1, 9000 Ghent (Belgium); Cools, P., E-mail: Pieter.Cools@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); Leys, C., E-mail: Christophe.Leys@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); De Geyter, N., E-mail: Nathalie.DeGeyter@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); Morent, R., E-mail: Rino.Morent@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium)

    2015-02-15

    Highlights: • Surface modification of polyethylene by an argon atmospheric pressure plasma jet. • Investigation of the influence of the applied power and argon flow rate. • Turbulence in the gas flow leads to a shorter afterglow. • Turbulence in the gas flow results in a lower wettability of the polyethylene. • Increasing the applied power increases the wettability of the polyethylene. - Abstract: Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1–1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the

  19. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    International Nuclear Information System (INIS)

    Highlights: • Surface modification of polyethylene by an argon atmospheric pressure plasma jet. • Investigation of the influence of the applied power and argon flow rate. • Turbulence in the gas flow leads to a shorter afterglow. • Turbulence in the gas flow results in a lower wettability of the polyethylene. • Increasing the applied power increases the wettability of the polyethylene. - Abstract: Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1–1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the

  20. Some metals determination in beers by atomic emission spectrometry of induced argon plasma

    International Nuclear Information System (INIS)

    It was made the identification and determination of metals in brazilian bottled and canned beer, using atomic emission spectrometry with d.c. are and argon coupled plasma excitation sources. The elements Co, Cr, Cu, Fe, Pb and Zn were determined in beer samples, after treatment with HNO sub(3) conc. /H sub(2) O sub(2) (30%). In the determination of Co, Cr, Cu, Pb and Zn and alternative method using HNO sub(3) conc. /O sub(3) was proved be useful. The results obtained for Co, Cr, Cu, Fe, Pb and Zn were below the limits established by brazilian legislation, showing the good quality of the beer concerning the metals. The results of this work were requested by the previous Ministerio do Meio Ambiente e Urbanismo in order to contribute to review the brazilian legislation in foods and beverages about metals contents. (author)

  1. Energy spectrum of argon ions emitted from Filippov type Sahand plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadnejad, M.; Pestehe, S. J.; Mohammadi, M. A. [Department of Atomic and Molecular Physics, Faculty of Physics, University of Tabriz, Postal Code 5166614766, Tabriz (Iran, Islamic Republic of); Research Institute for Applied Physics and Astronomy, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2013-07-15

    The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy.

  2. Exploring the electron density in plasmas induced by extreme ultraviolet radiation in argon

    Science.gov (United States)

    van der Horst, R. M.; Beckers, J.; Osorio, E. A.; Banine, V. Y.

    2015-07-01

    The new generation of lithography tools use high energy EUV radiation which ionizes the present background gas due to photoionization. To predict and understand the long term impact on the highly delicate mirrors, it is essential to characterize these kinds of EUV-induced plasmas. We measured the electron density evolution in argon gas during and just after irradiation by a short pulse of EUV light at 13.5 nm by applying microwave cavity resonance spectroscopy. Dependencies on EUV pulse energy and gas pressure have been explored over a range relevant for industrial applications. Our experimental results show that the maximum reached electron density depends linearly on pulse energy. A quadratic dependence caused by photoionization and subsequent electron impact ionization by free electrons is found from experiments where the gas pressure is varied. This is demonstrated by our theoretical estimates presented in this manuscript as well.

  3. Numerical study on iron particles behaviour injected in an argon plasma from an electric transferred arc

    Energy Technology Data Exchange (ETDEWEB)

    Douce, A.; Flour, I.

    1995-11-01

    In the scope of the Research and Development Project `Control of Plasma/Product Interaction`, the aim of this study is to analyze the behaviour of iron particles injected in an argon plasma flow from an electric transferred arc. It includes particle trajectories and, heat and mass transfer (as the particle undergoes smelting and evaporation), using a 3 dimensional Lagrangian simulation with the numerical code ESTET. The plasma flow is a result of a calculation done using Melodie, a 2 dimensional axisymmetrical software, in the scope of a modelling bath heating with plasma transferred arc. The first step consists of an analysis on the forces applied to a single particle. Simulations show that equation of motion would reduce, finally, to the sum of the drag force and the gravitational effects. In a second step, special attention is given to the effect of steep temperature gradients (across the boundary layer around the particle) on the evaluation of the plasma properties, the drag coefficient, and the heat and mass transfer coefficients. The comparison of several correlations show that the definition of the mean temperature mainly controls the calculation of plasma properties across the boundary layer around the particle.At least, several particle injection conditions are tested on four different sizes particles (50, 100, 150 et 200{mu}m), showing that the 200 {mu}m particle is the only one falling into the bath, without being completely evaporated. However, taking into account the `blow-up effect`, induced by evaporation, leads to a decrease of the heat transfer coefficient which slow down the evaporation, and then modify the conclusion made before. (authors). 18 refs., 41 figs., 5 tabs., 4 appends.

  4. Time- and space-resolved spectroscopic characterization of a laser carbon plasma plume in an argon background

    International Nuclear Information System (INIS)

    We present time- and space-resolved spectroscopic observations of a laser-produced carbon plasma, in an argon background. An Nd : YAG laser pulse, 370 mJ, 3.5 ns, at 1.06 µm, with a fluence of 6.9 J cm−2, is used to produce a plasma from a solid graphite target in a 0.5 to 415 mTorr argon background. The spectral emission in the visible is recorded with 15 ns time resolution. We use 20 ns time resolution plasma imaging, filtered at characteristic carbon species emission wavelengths, to study the dynamics of the expanding plasma. The carbon plasma emission is found to evolve from the characteristic of single ionized carbon, to a more complex one, where C2 and C3 molecular bands dominate. Several plasma fronts, with either ionic or molecular composition, are seen to detach from the laser target plasma. The temporal and spatial features of the molecular carbon species evolution are found to be dependent on the actual argon background pressure. (paper)

  5. Superhydrophilic poly(L-lactic acid) electrospun membranes for biomedical applications obtained by argon and oxygen plasma treatment

    Science.gov (United States)

    Correia, D. M.; Ribeiro, C.; Botelho, G.; Borges, J.; Lopes, C.; Vaz, F.; Carabineiro, S. A. C.; Machado, A. V.; Lanceros-Méndez, S.

    2016-05-01

    Poly(L-lactic acid), PLLA, electrospun membranes and films were plasma treated at different times and power with argon (Ar) and oxygen (O2), independently, in order to modify the hydrophobic nature of the PLLA membranes. Both Ar and O2 plasma treatments promote an increase in fiber average size of the electrospun membranes from 830 ± 282 nm to 866 ± 361 and 1179 ± 397 nm, respectively, for the maximum exposure time (970 s) and power (100 W). No influence of plasma treatment was detected in the physical-chemical characteristics of PLLA, such as chemical structure, polymer phase or degree of crystallinity. On the other hand, an increase in the roughness of the films was obtained both with argon and oxygen plasma treatments. Surface wettability studies revealed a decrease in the contact angle with increasing plasma treatment time for a given power and with increasing power for a given time in membranes and films and superhydrophilic electrospun fiber membranes were obtained. Results showed that the argon and oxygen plasma treatments can be used to tailor hydrophilicity of PLLA membranes for biomedical applications. MTT assay results indicated that plasma treatments under Ar and O2 do not influence the metabolic activity of MC3T3-E1 pre-osteoblast cells.

  6. Introduction of sulfate groups on poly(ethylene) surfaces by argon plasma immobilization of sodium alkyl sulfates

    NARCIS (Netherlands)

    Lens, J.P.; Terlingen, J.G.A.; Engbers, G.H.M.; Feijen, J.

    1998-01-01

    Sulfate groups were introduced at the surface of poly(ethylene) (PE) samples. This was accomplished by immobilizing a precoated layer of either sodium 10-undecene sulfate (S11(:)) or sodium dodecane sulfate (SDS) on the polymeric surface by means of an argon plasma treatment. For this purpose, S11(:

  7. In vitro and in vivo microbial adhesion and growth on argon plasma-treated silicone rubber voice prostheses

    NARCIS (Netherlands)

    Everaert, EPJM; Van de Belt-Gritter, B; Van der Mei, HC; Busscher, HJ; Verkerke, GJ; Dijk, F; Mahieu, HF; Reitsma, A

    1998-01-01

    Patients who undergo a total laryngectomy usually receive a silicone rubber voice prosthesis for voice rehabilitation. Unfortunately, biofilm formation on the esophageal side of voice prostheses limits their lifetime to 3-4 mon on average. The effects of repeated argon plasma treatment of medical gr

  8. Effects of water addition on OH radical generation and plasma properties in an atmospheric argon microwave plasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, Nimisha; Wang Chuji [Department of Physics and Astronomy and the Energy Institute, Mississippi State University, Mississippi State, Mississippi 39762 (United States)

    2011-09-01

    Water vapor was added to the feeding gas of a continuous atmospheric argon (Ar) microwave plasma jet to study its influence on plasma shape, plasma gas temperature, and OH radical concentrations. The plasma jet was created by a 2.45 GHz microwave plasma source operating at constant power of 104 W with H{sub 2}O-Ar mixture flow rate of 1.7 standard liter per minute (slm). With an increase in the H{sub 2}O/Ar ratio from 0.0 to 1.9%, the plasma jet column length decreased from 11 mm to 4 mm, and the plasma jet became unstable when the ratio was higher than 1.9%; elevation of plasma gas temperature up to 330 K was observed in the plasma temperature range of 420-910 K. Optical emission spectroscopy showed that the dominant plasma emissions changed from N{sub 2} in the pure Ar plasma jet to OH with the addition of water vapor, and simulations of emission spectra suggested non-Boltzmann distribution of the rotational levels in the OH A-state (v'=0). Spatially resolved absolute OH number densities along the plasma jet axis were measured using UV cavity ringdown spectroscopy of the OH (A-X) (0-0) band in the H{sub 2}O/Ar ratio range of 0.0-1.9%. The highest OH number density is consistently located in the vicinity of the plasma jet tip, regardless of the H{sub 2}O/Ar ratio. OH number density in the post-tip region follows approximately an exponential decay along the jet axis with the fastest decay constant of 3.0 mm in the H{sub 2}O/Ar ratio of 1.5%. Given the low gas temperature of 420-910 K and low electron temperature of 0.5-5 eV along the jet axis, formation of the OH radical is predominantly due to electron impact induced dissociation of H{sub 2}O and dissociative recombination of H{sub 2}O{sup +} resulting from the Penning ionization process.

  9. Predictive modelling of the impact of argon injection on H-mode plasmas in JET with the RITM code

    Energy Technology Data Exchange (ETDEWEB)

    Unterberg, B [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, Ass. Euratom-FZ Juelich, D-52425 Juelich (Germany); Kalupin, D [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, Ass. Euratom-FZ Juelich, D-52425 Juelich (Germany); Tokar' , M Z [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, Ass. Euratom-FZ Juelich, D-52425 Juelich (Germany); Corrigan, G [EURATOM UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Dumortier, P [Laboratory for Plasma Physics, Ass. Euratom-Belgian State, Koninklijke Militaire School-Ecole Royale Militaire, B-1000 Brussels (Belgium); Huber, A [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, Ass. Euratom-FZ Juelich, D-52425 Juelich (Germany); Jachmich, S [Laboratory for Plasma Physics, Ass. Euratom-Belgian State, Koninklijke Militaire School-Ecole Royale Militaire, B-1000 Brussels (Belgium); Kempenaars, M [FOM-Instituut voor Plasmafysica ' Rijnhuizen' , Ass. Euratom-FOM, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Kreter, A [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, Ass. Euratom-FZ Juelich, D-52425 Juelich (Germany); Messiaen, A M [Laboratory for Plasma Physics, Ass. Euratom-Belgian State, Koninklijke Militaire School-Ecole Royale Militaire, B-1000 Brussels (Belgium); Monier-Garbet, P [Ass. Euratom-CEA, DRFC, CEA Cadarache, St Paul lez Durance (France); Ongena, J [Laboratory for Plasma Physics, Ass. Euratom-Belgian State, Koninklijke Militaire School-Ecole Royale Militaire, B-1000 Brussels (Belgium); Puiatti, M E [Associazione Euratom-ENEA sulla Fusione, Consorzio RFX, Padova (Italy); Valisa, M [Associazione Euratom-ENEA sulla Fusione, Consorzio RFX, Padova (Italy); Hellermann, M von [FOM-Instituut voor Plasmafysica ' Rijnhuizen' , Ass. Euratom-FOM, PO Box 1207, 3430 BE Nieuwegein(Netherlands)

    2004-05-01

    Self-consistent modelling of energy and particle transport of the plasma background and impurities has been performed with the code RITM for argon seeded high density H-mode plasmas in JET. The code can reproduce both the profiles in the plasma core and the structure of the edge pedestal. The impact of argon on core transport is found to be small; in particular, no significant change in confinement is observed in both experimental and modelling results. The same transport model, which has been used to reproduce density peaking in the radiative improved mode in TEXTOR, reveals a flat density profile in Ar seeded JET H-mode plasmas in agreement with the experimental observations. This behaviour is attributed to the rather flat profile of the safety factor in the bulk of H-mode discharges.

  10. Systematic studies of covalent functionalization of carbon nanotubes via argon plasma-assisted UV grafting

    International Nuclear Information System (INIS)

    Single-walled carbon nanotubes (SWNTs) with 1-vinylimidazole species covalently attached to their sidewalls and end caps have been prepared by ultraviolet (UV) irradiation in 1-vinylimidazole monomer. This process can be greatly assisted by argon (Ar) plasma pretreatment, which generates more defect sites at the tube ends and sidewalls acting as the active sites for the subsequent UV grafting of 1-vinylimidazole molecules. The effects of total deposited energy of Ar plasma treatment, either by change of treatment time or discharge power, on the functionalization degree and structural morphology of the resulting nanotubes are systematically studied. By control of the Ar plasma treatment time within 5 min at the discharge power of 200 W, no visible chopping of the functionalized SWNTs was observed. Under this advised optimum processing condition, the functionalization degree, estimated by x-ray photoelectron spectroscopy (XPS) measurement, is as high as around 26 wt% 1-vinylimidazole molecules grafted onto the nanotubes. This method may be extended to other reactive vinyl monomers and offers another diverse way of covalent functionalization of SWNTs

  11. Plasma Formed in Argon, Acid Nitric and Water Used in Industrial ICP Torches

    Institute of Scientific and Technical Information of China (English)

    F. BENDJEBBAR; P. ANDRE; M. BENBAKKAR; D. ROCHETTE; S. FLAZI; D. VACHER

    2012-01-01

    Inductively coupled plasmas (ICPs) are used in spectrochemical analyses. The introduction of the sample by means of an aerosol are widely used. The introduction and the total evaporation of the aerosol is required in order to obtain a good repeatability and reproducibility of analyses. To check whether the vaporization of the aerosol droplets inside the plasma is completed, a solution could be used to compare the experimental results of the emission spectral lines with theoretical results. An accurate calculation code to obtain monatomic spectral lines intensities is therefore required, which is the purpose of the present paper. The mixtures of argon, water and nitric acid are widely used in spectrochemical analyses with ICPs. With these mixtures, we calculate the composition, thermodynamic functions and monatomic spectral lines intensities of the plasma at thermodynamic equilibrium and at atmospheric pressure. To obtain a self sufficient paper and also to allow other researchers to compare their results, all required data and a robust accurate algorithm, which is simple and easy to compute, are given.

  12. Laboratory experiments in the argon plasma perturbed by injections of the electronegative gases

    Science.gov (United States)

    Zhang, Xiao; Cao, Jin-xiang; Liu, Yu; Yu, Peng-cheng; Zhang, Zhong-kai

    2016-07-01

    In this study, laboratory observations of the perturbations of the magnetic field are reported due to the injection of attachment chemicals (CF4, SF6, and CO2) into argon plasmas. Besides the well-known electron density reduction, we also observed magnetic field perturbation in the experiment. The measured induced voltage B ˙ , which is taken as a proxy of the time-changing electromagnetic field, fluctuates in the boundary layer between the ambient plasmas and negative ions plasmas. Perturbations of the magnetic field were investigated by changing the ambient pressure and ratio of attachment chemicals. The measured B ˙ keeps increasing in these lower pressures; but it no longer increases as the ambient pressure higher than a threshold, e.g., for CF4, SF6, and CO2, the transition pressure is 6Pa, 5Pa and 4Pa, respectively. The magnitude of the B ˙ increase with the change of the ratio of release flow until at higher ratios, e.g., 40%. We transformed these time-sampled data into the frequency domain and found coherent modes with fundamental frequencies lying in the lower hybrid range. In addition, these coherent frequencies show a frequency drift with the increase of the contents of the negative ions. These modes were suggested as the magnetic component of electron-ion hybrid mode. This work has an important application in the study of artificially-created ionospheric depletion which is usually generated by releasing of attachment chemicals in the upper atmosphere.

  13. Pulsed microwave-driven argon plasma jet with distinctive plume patterns resonantly excited by surface plasmon polaritons

    Science.gov (United States)

    Chen, Zhao-Quan; Yin, Zhi-Xiang; Xia, Guang-Qing; Hong, Ling-Li; Hu, Ye-Lin; Liu, Ming-Hai; Hu, Xi-Wei; A. Kudryavtsev, A.

    2015-02-01

    Atmospheric lower-power pulsed microwave argon cold plasma jets are obtained by using coaxial transmission line resonators in ambient air. The plasma jet plumes are generated at the end of a metal wire placed in the middle of the dielectric tubes. The electromagnetic model analyses and simulation results suggest that the discharges are excited resonantly by the enhanced electric field of surface plasmon polaritons. Moreover, for conquering the defect of atmospheric argon filamentation discharges excited by 2.45-GHz of continued microwave, the distinctive patterns of the plasma jet plumes can be maintained by applying different gas flow rates of argon gas, frequencies of pulsed modulator, duty cycles of pulsed microwave, peak values of input microwave power, and even by using different materials of dielectric tubes. In addition, the emission spectrum, the plume temperature, and other plasma parameters are measured, which shows that the proposed pulsed microwave plasma jets can be adjusted for plasma biomedical applications. Project supported by the National Natural Science Foundation of China (Grant Nos. 11105002 and 61170172), the Natural Science Foundation of Anhui Province, China (Grant Nos. 1408085QA16 and 1408085ME101), the China Postdoctoral Science Foundation (Grant No. 2014M551788), and the Open-end Fund of State Key Laboratory of Advanced Electromagnetic Engineering and Technology (HUST), China (Grant No. GZ1301).

  14. A cartridge based sensor array platform for multiple coagulation measurements from plasma

    OpenAIRE

    Kavaklı, İbrahim Halil; Çakmak, Onur; Ermek, Erhan; Kılınç, Necmettin; Bulut, Sinan; Barış, İbrahim; Ürey, Hakan; Yaralıoğlu, Göksenin

    2015-01-01

    This paper proposes a MEMS-based sensor array enabling multiple clot-time tests for plasma in one disposable microfluidic cartridge. The versatile LoC (Lab-on-Chip) platform technology is demonstrated here for real-time coagulation tests (activated Partial Thromboplastin Time (aPTT) and Prothrombin Time (PT)). The system has a reader unit and a disposable cartridge. The reader has no electrical connections to the cartridge. This enables simple and low-cost cartridge designs and avoids reliabi...

  15. Characterization of Modified Tapioca Starch in Atmospheric Argon Plasma under Diverse Humidity by FTIR Spectroscopy

    International Nuclear Information System (INIS)

    Tapioca is economical crop grown in Thailand and continues to be one of the major sources of starch. Nowadays, tapioca starch has been widely used in industrial applications, however the native form of starch has limited the applications. Thus scientists try to modify the properties of starch for increasing the stability of the granules, pastes to low pH, heat, and shear during the food process. We modify the tapioca starch by plasma treatment under an argon atmosphere. The degree of modification is determined by following water content in the starch granules. The tablet samples of native starch are also prepared and compared with the plasma treated starch. Before plasma treatment, the starch tablets are stored under three different relative humilities (RH) including 11%, 68%, and 78%RH, respectively. The samples are characterized using FTIR spectroscopy associated with the degree of cross-linking. The results show that the water molecules are engulfed into the starch structure in two ways, a tight bond and a weak absorption of water molecules which is represented at two wave number of 1630 cm−1 and 3272 cm−1, respectively. The degree of cross-linking can be identified from the relative intensity of these two peaks with the C—O—H peak at 993 cm−1. The results show that the degree of cross-linking increase in the plasma treated starch. The degree of cross-linking of the treated starch with high relative humidity is less than that of the treated starch with low relative humidity

  16. Characterization of Modified Tapioca Starch in Atmospheric Argon Plasma under Diverse Humidity by FTIR Spectroscopy

    Science.gov (United States)

    Deeyai, P.; Suphantharika, M.; Wongsagonsup, R.; Dangtip, S.

    2013-01-01

    Tapioca is economical crop grown in Thailand and continues to be one of the major sources of starch. Nowadays, tapioca starch has been widely used in industrial applications, however the native form of starch has limited the applications. Thus scientists try to modify the properties of starch for increasing the stability of the granules, pastes to low pH, heat, and shear during the food process. We modify the tapioca starch by plasma treatment under an argon atmosphere. The degree of modification is determined by following water content in the starch granules. The tablet samples of native starch are also prepared and compared with the plasma treated starch. Before plasma treatment, the starch tablets are stored under three different relative humilities (RH) including 11%, 68%, and 78%RH, respectively. The samples are characterized using FTIR spectroscopy associated with the degree of cross-linking. The results show that the water molecules are engulfed into the starch structure in two ways, a tight bond and a weak absorption of water molecules which is represented at two wave number of 1630 cm-1 and 3272 cm-1, respectively. The degree of cross-linking can be identified from the relative intensity of these two peaks with the C—O—H peak at 993 cm-1. The results show that the degree of cross-linking increase in the plasma treated starch. The degree of cross-linking of the treated starch with high relative humidity is less than that of the treated starch with low relative humidity.

  17. Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces:In vitro study

    Science.gov (United States)

    Annunziata, Marco; Donnarumma, Giovanna; Caputo, Pina; Nastri, Livia; Guida, Luigi

    2016-01-01

    Background Surface treatment by argon plasma is widely used as the last step of the manufacturing process of titanium implant fixtures before their sterilization by gamma rays. The possibility of using such a technology in the daily clinical practice is particularly fascinating. The aim of the present study was to assess the effects of the argon plasma treatment on different titanium implant surfaces previously exposed In vitro to bacterial contamination. Material and Methods Sterile c.p. titanium implant discs with turned (T, Sa: 0.8 µm ), sandblasted/acid-etched (SAE, Sa: 1.3 µm) and titanium plasma sprayed (TPS, Sa: 3.0µm) surface were used in this study. A strain of Aggregatibacter actinomycetemcomitans ATCC3718 was grown at 37°C under anaerobic conditions for 24 h and then transferred on six discs for each of the three surface types. After 24 hours, a half of the contaminated discs (control group) were directly used to evaluate the colony forming units (CFUs). The other half of the contaminated discs (test group) were treated in an argon plasma chamber for 12 minutes at room temperature prior to be analyzed for CFU counting. All assays were performed using triplicate samples of each material in 3 different experiments. Results When the CFU counting was carried out on control discs, a total of 1.50x106±1.4x105, 1.55x106±7.07x104 and 3.15x106±2.12x105 CFU was respectively assessed for T, SAE and TPS discs, without statistically significant differences among the three surfaces. On the contrary, any trace of bacterial contamination was assessed for titanium discs treated in the argon plasma chamber prior to be analyzed, irrespectively to the implant surface tested. Conclusions Within the limit of this study, reported data suggested that the argon plasma technology could be efficiently used to decontaminate/sterilize previously infected titanium implant surfaces. Key words:Argon plasma, titanium implant surface, Aggregatibacter actinomycetemcomitans. PMID

  18. Radiative Transition Line Shape in Warm and Dense Argon Plasma: a Two-Centre Model Study

    Institute of Scientific and Technical Information of China (English)

    MENG Cong-Sen; ZHAO Zeng-Xiu; YUAN Jian-Min

    2008-01-01

    A two-centre model is employed to study the electronic structure of argon plasma at a density of 1022cm-3 and a temperature of 5eV. The model takes into account the influence of the nearest neighbour on the electronic structure of the radiator and gives a proper description of the transient molecular behaviour in dense plasmas where the mean interatomic distance can be the order of the orbital spatial extent. The orbital energies of quasi-molecular Ar,2 against the interatomic distance are calculated in the framework of density functional theory. It is shown that the orbital energies are not monotonic functions of the distance because of two competitive effects: the repulsive potential between electrons and the attractive potential between electrons and nuclei. The characteristics of this two-centre system can be categorized by three regimes depending on the ratio between the electron wavelength and the interatomic distance: atomic regime, screened atomic regime, and quasi-molecular regime. This classification agrees qualitatively with the conclusion of full quantum-mechanical approach [Yonger S M et al 1988 Phys. Rev. Lett. 61962].

  19. Discharge processes and an electrical model of atmospheric pressure plasma jets in argon

    Science.gov (United States)

    Fang, Zhi; Shao, Tao; Yang, Jing; Zhang, Cheng

    2016-01-01

    In this paper, an atmospheric pressure plasma discharge in argon was generated using a needle-to-ring electrode configuration driven by a sinusoidal excitation voltage. The electric discharge processes and discharge characteristics were investigated by inspecting the voltage-current waveforms, Lissajous curves and lighting emission images. The change in discharge mode with applied voltage amplitude was studied and characterised, and three modes of corona discharge, dielectric barrier discharge (DBD) and jet discharge were identified, which appeared in turn with increasing applied voltage and can be distinguished clearly from the measured voltage-current waveforms, light-emission images and the changing gradient of discharge power with applied voltage. Based on the experimental results and discharge mechanism analysis, an equivalent electrical model and the corresponding equivalent circuit for characterising the whole discharge processes accurately was proposed, and the three discharge stages were characterised separately. A voltage-controlled current source (VCCS) associated with a resistance and a capacitance were used to represent the DBD stage, and the plasma plume and corona discharge were modelled by a variable capacitor in series with a variable resistor. Other factors that can influence the discharge, such as lead and stray capacitance values of the circuit, were also considered in the proposed model. Contribution to the Topical Issue "Recent Breakthroughs in Microplasma Science and Technology", edited by Kurt Becker, Jose Lopez, David Staack, Klaus-Dieter Weltmann and Wei Dong Zhu.

  20. Study of argon plasma treatment of polycarbonate substrate and its effect on film deposition

    International Nuclear Information System (INIS)

    Results of polycarbonate plasma treatment in argon r.f. glow discharges as concern the chemical structure and surface free energy are presented. The oxygen-to-carbon ratio increased after the treatment indicating an increase of oxygen containing functional groups on the polycarbonate surface. Small amount of silicon as a result of previous depositions of organosilicon thin films in the same reactor and small amount of nitrogen coming probably from an exposure of the reactive surface to the atmosphere were found on the surface. The surface free energy increased after the treatment from the original value of 35 mJ/m2 to 63-74 mJ/M2. Effect of treatment time, gas flow rate, pressure and aging on the surface free energy was studied too. In order to study an improvement of adhesion between between the polycarbonate and an additional coatings the organosilicon thin films were deposited on the untreated and plasma treated polycarbonate. The interfacial fracture resistance of such a system was qualitatively tested by cross-hatch peel test. The initiation and propagation stage of the fracture were studied by depth sensing indentation method followed by an observation of the samples with an optical microscope (Authors)

  1. Effects of metastable species in helium and argon atmospheric pressure plasma jets (APPJs) on inactivation of periodontopathogenic bacteria

    Science.gov (United States)

    Yoon, Sung-Young; Kim, Kyoung-Hwa; Seol, Yang-Jo; Kim, Su-Jeong; Bae, Byeongjun; Huh, Sung-Ryul; Kim, Gon-Ho

    2016-05-01

    The helium and argon have been widely used as discharge gases in atmospheric pressure plasma jets (APPJs) for bacteria inactivation. The APPJs show apparent different in bullet propagation speed and bacteria inactivation rate apparently vary with discharge gas species. This work shows that these two distinctive features of APPJs can be linked through one factor, the metastable energy level. The effects of helium and argon metastable species on APPJ discharge mechanism for reactive oxygen nitrogen species (RONS) generation in APPJs are investigated by experiments and numerical estimation. The discharge mechanism is investigated by using the bullet velocity from the electric field which is obtained with laser induced fluorescence (LIF) measurement. The measured electric field also applied on the estimation of RONS generation, as electron energy source term in numerical particle reaction. The estimated RONS number is verified by comparing NO and OH densities to the inactivation rate of periodontitis bacteria. The characteristic time for bacteria inactivation of the helium-APPJ was found to be 1.63 min., which is significantly less than that of the argon-APPJ, 12.1 min. In argon-APPJ, the argon metastable preserve the energy due to the lack of the Penning ionization. Thus the surface temperature increase is significantly higher than helium-APPJ case. It implies that the metastable energy plays important role in both of APPJ bullet propagation and bacteria inactivation mechanism.

  2. Calculations on charge state and energy loss of argon ions in partially and fully ionized carbon plasmas.

    Science.gov (United States)

    Barriga-Carrasco, Manuel D; Casas, David; Morales, Roberto

    2016-03-01

    The energy loss of argon ions in a target depends on their velocity and charge density. At the energies studied in this work, it depends mostly on the free and bound electrons in the target. Here the random-phase approximation is used for analyzing free electrons at any degeneracy. For the plasma-bound electrons, an interpolation between approximations for low and high energies is applied. The Brandt-Kitagawa (BK) model is employed to depict the projectile charge space distribution, and the stripping criterion of Kreussler et al. is used to determine its equilibrium charge state Q(eq). This latter criterion implies that the equilibrium charge state depends slightly on the electron density and temperature of the plasma. On the other hand, the effective charge Q(eff) is obtained as the ratio between the energy loss of the argon ion and that of the proton for the same plasma conditions. This effective charge Q(eff) is larger than the equilibrium charge state Q(eq) due to the incorporation of the BK charge distribution. Though our charge-state estimations are not exactly the same as the experimental values, our energy loss agrees quite well with the experiments. It is noticed that the energy loss in plasmas is higher than that in the same cold target of about, ∼42-62.5% and increases with carbon plasma ionization. This confirms the well-known enhanced plasma stopping. It is also observed that only a small part of this energy loss enhancement is due to an increase of the argon charge state, namely only ∼2.2 and 5.1%, for the partially and the fully ionized plasma, respectively. The other contribution is connected with a better energy transfer to the free electrons at plasma state than to the bound electrons at solid state of about, ∼38.8-57.4%, where higher values correspond to a fully ionized carbon plasma. PMID:27078472

  3. Calculations on charge state and energy loss of argon ions in partially and fully ionized carbon plasmas

    Science.gov (United States)

    Barriga-Carrasco, Manuel D.; Casas, David; Morales, Roberto

    2016-03-01

    The energy loss of argon ions in a target depends on their velocity and charge density. At the energies studied in this work, it depends mostly on the free and bound electrons in the target. Here the random-phase approximation is used for analyzing free electrons at any degeneracy. For the plasma-bound electrons, an interpolation between approximations for low and high energies is applied. The Brandt-Kitagawa (BK) model is employed to depict the projectile charge space distribution, and the stripping criterion of Kreussler et al. is used to determine its equilibrium charge state Qeq. This latter criterion implies that the equilibrium charge state depends slightly on the electron density and temperature of the plasma. On the other hand, the effective charge Qeff is obtained as the ratio between the energy loss of the argon ion and that of the proton for the same plasma conditions. This effective charge Qeff is larger than the equilibrium charge state Qeq due to the incorporation of the BK charge distribution. Though our charge-state estimations are not exactly the same as the experimental values, our energy loss agrees quite well with the experiments. It is noticed that the energy loss in plasmas is higher than that in the same cold target of about, ˜42 -62.5 % and increases with carbon plasma ionization. This confirms the well-known enhanced plasma stopping. It is also observed that only a small part of this energy loss enhancement is due to an increase of the argon charge state, namely only ˜2.2 and 5.1 % , for the partially and the fully ionized plasma, respectively. The other contribution is connected with a better energy transfer to the free electrons at plasma state than to the bound electrons at solid state of about, ˜38.8 -57.4 % , where higher values correspond to a fully ionized carbon plasma.

  4. Exploring the electron density in plasma induced by EUV radiation: II. Numerical studies in argon and hydrogen

    CERN Document Server

    Astakhov, D I; Lee, C J; Ivanov, V V; Krivtsun, V M; Koshelev, K N; Lopaev, D V; van der Horst, R M; Beckers, J; Osorio, E A; Bijkerk, F

    2016-01-01

    We used numerical modeling to study the evolution of EUV-induced plasmas in argon and hydrogen. The results of simulations were compared to the electron densities measured by microwave cavity resonance spectroscopy. It was found that the measured electron densities can be used to derive the integral amount of plasma in the cavity. However, in some regimes, the impact of the setup geometry, EUV spectrum, and EUV induced secondary emission should be taken into account. The influence of these parameters on the generated plasma and the measured electron density is discussed.

  5. Exploring the electron density in plasma induced by EUV radiation: II. Numerical studies in argon and hydrogen

    Science.gov (United States)

    Astakhov, D. I.; Goedheer, W. J.; Lee, C. J.; Ivanov, V. V.; Krivtsun, V. M.; Koshelev, K. N.; Lopaev, D. V.; van der Horst, R. M.; Beckers, J.; Osorio, E. A.; Bijkerk, F.

    2016-07-01

    We used numerical modeling to study the evolution of EUV-induced plasmas in argon and hydrogen. The results of simulations were compared to the electron densities measured by microwave cavity resonance spectroscopy. It was found that the measured electron densities can be used to derive the integral amount of plasma in the cavity. However, in some regimes, the impact of the setup geometry, EUV spectrum, and EUV induced secondary emission should be taken into account. The influence of these parameters on the generated plasma and the measured electron density is discussed.

  6. Experimental investigation of the structure and the dynamics of nanosecond laser-induced plasma in 1-atm argon ambient gas

    Science.gov (United States)

    Ma, Qianli; Motto-Ros, Vincent; Bai, Xueshi; Yu, Jin

    2013-11-01

    We have investigated the structure and the dynamics of the plasma induced on a metallic target in 1-atm argon ambient by a nanosecond laser pulse with irradiance in the range of 10 GW/cm2. The structure is revealed to be sensitively dependent on the laser wavelength. A layered structure of different species characterizes the plasma induced by ultraviolet 355 nm pulse, while an effective mixing between the ablation vapor and the shocked ambient gas is observed with infrared 1064 nm pulse. The absorption property of the shocked gas is found to be crucial for determining the structure of the plasma.

  7. Effect of Argon Plasma Treatment on Tribological Properties of UHMWPE/MWCNT Nanocomposites

    Directory of Open Access Journals (Sweden)

    Nitturi Naresh Kumar

    2016-08-01

    Full Text Available Ultra-high molecular weight polyethylene (UHMWPE is widely used in artificial joints in the replacement of knee, hip and shoulder that has been impaired as a result of arthritis or other degenerative joint diseases. The UHMWPE made plastic cup is placed in the joint socket in contact with a metal or ceramic ball affixed to a metal stem. Effective reinforcement of multi-walled carbon nanotubes (MWCNTs in UHMWPE results in improved mechanical and tribological properties. The hydrophobic nature of the nanocomposites surface results in lesser contact with biological fluids during the physiological interaction. In this project, we investigate the UHMWPE/MWCNTs nanocomposites reinforced with MWCNTs at different concentrations. The samples were treated with cold argon plasma at different exposure times. The water contact angles for 60 min plasma-treated nanocomposites with 0.0, 0.5, 1.0, 1.5, and 2.0 wt % MWCNTs were found to be 55.65°, 52.51°, 48.01°, 43.72°, and 37.18° respectively. Increasing the treatment time of nanocomposites has shown transformation from a hydrophobic to a hydrophilic nature due to carboxyl groups being bonded on the surface for treated nanocomposites. Wear analysis was performed under dry, and also under biological lubrication, conditions of all treated samples. The wear factor of untreated pure UHMWPE sample was reduced by 68% and 80%, under dry and lubricated conditions, respectively, as compared to 2 wt % 60 min-treated sample. The kinetic friction co-efficient was also noted under both conditions. The hardness of nanocomposites increased with both MWCNTs loading and plasma treatment time. Similarly, the surface roughness of the nanocomposites was reduced.

  8. The influence of C2H2 and dust formation on the time dependence of metastable argon density in pulsed plasmas

    OpenAIRE

    Stefanovic, Ilija; Sadeghi, Nader; Winter, Jörg

    2010-01-01

    Abstract Diode laser absorption at 772.38 nm is used to measure the time resolved density of Ar*(3 P 2) metastable atoms in a capacitively coupled radio-frequency (RF) discharge running in argon/acetylene mixture at 0.1 mbar. The RF power is pulsed at 100 Hz and the density of Ar*(3 P 2) atoms in the 5 ms ON time and in the afterglow are recorded. Different plasma conditions, namely: 1) pure argon, 2) argon + 7% acetylene before powder formation, 3) argon + 7% acetylene after dust particle...

  9. An Experimental Study of the Drag Force on a Cylinder Exposed to an Argon Thermal Plasma Cross Flow

    Institute of Scientific and Technical Information of China (English)

    XinTao; XiChen; 等

    1992-01-01

    Experimental data are presented concerning the drag force on a cylinder exposed to an argon plasma cross flow with temperatures about 104 K and velocities about 102 m/s.Using a method of sweeping a cylindrical probe across an argon plasma jet,the total drag force on the cylinder can be measured as a function of the lateral distance of cylindrical probe with respect to the plasma-jet axis.Through the Abel inversion,the drag force for per unit of cylinderlength and thus the drag coefflcient of cylinder have been measured under plasma conditions and compared with the values obtained from the standard drag curve of the cylinder in an isothermal flow.Experimental results show that the measured grag forces are always less than their counterparts read from the standard drag curve with the smae Reynolds numbers based on the oncoming plasma properties.Thew drag force on the cylinder exoposed to a thermal plasma flow is shown to be approximately proportional to the square root of cylinder diameter in the present experiment and it increases slightly proportional to the square root of cylinder diameter in the present experiment and if increases slightly with increasing surface temperature of the cylinder,.It is also shown that applying a voltage between the drag prode and the anode of the plasma jet generator has little effect on the drag force of cylinder under the experimental conditions.The drag force on a cylinder with finite length exposed to an argon plasma with the axis parallel to the plams jet is independent of ration of cylinder length to its dismeter L/d for the cases when L/d≤1.

  10. [Trimming with argon plasma of self-expanding metal stents: report of 7 cases].

    Science.gov (United States)

    Jury, Gastón; Amieva, Leandro; López, Fagalde Rafael; Jury, Rubén

    2014-06-01

    The use of self-expandable enteral stents for palliation of malignant stenosis may present the complication of concealing the ampulla of Vater behind the metallic mesh. Anchoring in the duodenal wall (distal or partial migration) may also be a complication of biliary metallic stents and therefore may cause difficulty in gaining access to the biliary tract. In these cases of difficult access, a fenestration on the prosthesis ( biliary or enteral) can be created to allow reaching the obstructed biliary tract by means of argon plasma (AP). Were retrospectively analysed 7 cases. Under endoscopic vision, AP was directed to filgurate and cut 6 biliary prosthesis and a duodenal stent. Fulguration and cut of biliary stent was performed in 5 cases of distal partial migration and cholangitis. In one case of obstruction caused by distal migration inside the duodenal stent light, cutting of the biliary stent was performed. A window was created in the enteral prosthesis in order to access the ampulla of Vater and place a biliary tract prosthesis. All cases were resolved successfully and without complications. We conclude that the use of AP to fulgurate and cut nitinol prosthesis was effective and presented no complications in this series. PMID:25199306

  11. Effect of Fast Curing Lights, Argon Laser, and Plasma Arc on Bond Strengths of Orthodontic Brackets: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    M. Hashem-Hoseini

    2008-12-01

    Full Text Available Objective: Nowadays light-cured composites are used widely by orthodontists to bond brackets. As these composites require 20-40 seconds time per tooth to be light cured, more chair-time in needed compared to self-cured composites. In recent years, the argon laser and plasma arc lights have been introduced in dentistry to reduce this curing time. The purpose of this study was to compare bond strength of brackets bonded with the argon la-ser and plasma arc light with those bonded with the conventional halogen light.Materials and Methods: Fifty-one intact human premolars were randomly divided into three groups of 17 teeth each. Stainless steel twin premolar brackets (018- in Dyna lock, 3M Unitek were bonded to the teeth using one of these curing devices in each group: the halogen unit (Coltolux 75, Switzerland, the argon laser unit (Bo-5, Iran , and the plasma arc unit (Remecure 15, Belgium. The orthodontic adhesive was the same in the three groups (Transbond XT, 3M Unitek. After thermal cycling, the diametral tensilebond strength of specimens was measured using a debonding plier in a Zwick Universal Testing machine (Z/100, Germany.Results: The mean bond strengths was 17.344 MPa (SD=4.567 for halogen 19.172 MPa(SD=6.328 for laser and 19.322 MPa (SD=4.036 for plasma arc groups. No statistically significant difference existed in the mean bond strengths among three groups.Conclusion: Argon laser lights, significantly reducing the curing time of orthodonticbrackets without affecting bond strength, have the potential to be considered as advanta-geous alternatives to conventional halogen light.

  12. Self-consistent fluid modeling and simulation on a pulsed microwave atmospheric-pressure argon plasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhaoquan, E-mail: zqchen@aust.edu.cn [Faculty of Physics, St. Petersburg State University, St. Petersburg 198504 (Russian Federation); College of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan, Anhui 232001 (China); Yin, Zhixiang, E-mail: zxyin66@163.com; Chen, Minggong; Hong, Lingli; Hu, Yelin; Huang, Yourui [College of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan, Anhui 232001 (China); Xia, Guangqing; Liu, Minghai [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Kudryavtsev, A. A. [Faculty of Physics, St. Petersburg State University, St. Petersburg 198504 (Russian Federation)

    2014-10-21

    In present study, a pulsed lower-power microwave-driven atmospheric-pressure argon plasma jet has been introduced with the type of coaxial transmission line resonator. The plasma jet plume is with room air temperature, even can be directly touched by human body without any hot harm. In order to study ionization process of the proposed plasma jet, a self-consistent hybrid fluid model is constructed in which Maxwell's equations are solved numerically by finite-difference time-domain method and a fluid model is used to study the characteristics of argon plasma evolution. With a Guass type input power function, the spatio-temporal distributions of the electron density, the electron temperature, the electric field, and the absorbed power density have been simulated, respectively. The simulation results suggest that the peak values of the electron temperature and the electric field are synchronous with the input pulsed microwave power but the maximum quantities of the electron density and the absorbed power density are lagged to the microwave power excitation. In addition, the pulsed plasma jet excited by the local enhanced electric field of surface plasmon polaritons should be the discharge mechanism of the proposed plasma jet.

  13. Atomic data generation and collisional radiative modeling of argon II, argon III, and neon I for laboratory and astrophysical plasmas

    Science.gov (United States)

    Munoz Burgos, Jorge Manuel

    Accurate knowledge of atomic processes plays a key role in modeling the emission in laboratory as well as in astrophysical plasmas. These processes are included in a collisional-radiative model and the results are compared with experimental measurements for Ar and Ne ions from the ASTRAL (Auburn Steady sTate Research fAciLity) experiment. The accuracy of our model depends upon the quality of the atomic data we use. Atomic data for near neutral systems present a challenge due to the low accuracy of perturbative methods for these systems. In order to improve our model we rely on non-perturbative methods such as R - Matrix and RMPS ( R -Matrix with Pseudo-States) to include correlation in the collision cross-sections. In the case of Ar + we compared R -Matrix electron-impact excitation data against the results from a new RMPS calculation. The aim was to assess the effects of continuum-coupling effects on the atomic data and the resulting spectrum. We do our spectral modeling using the ADAS suite of codes. Our collisional-radiative formalism assumes that the excited levels are in quasi- static equilibrium with the ground and metastable populations. In our model we allow for N e and T e variation along the line of sight by fitting our densities and temperature profiles with those measured within the experiment. The best results so far have been obtained by the fitting of the experimental temperature and density profiles with Gaussian and polynomial distribution functions. The line of sight effects were found to have a significant effect on the emission modeling. The relative emission rates were measured in the ASTRAL helicon plasma source. A spectrometer which features a 0.33 m Criss-Cross Scanning monochromator and a CCD camera is used for this study. ASTRAL produces bright intense Ar and Ne plasmas with n e = 10 11 to 10 13 cm -3 and T e = 2 to 10 eV. A series of 7 large coils produce an axial magnetic field up to 1.3 kGauss. A fractional helix antenna is used to

  14. Argon-germane in situ plasma clean for reduced temperature Ge on Si epitaxy by high density plasma chemical vapor deposition

    International Nuclear Information System (INIS)

    We found that the demand for integration of near infrared optoelectronic functionality with silicon complementary metal oxide semiconductor (CMOS) technology has for many years motivated the investigation of low temperature germanium on silicon deposition processes. Our work describes the development of a high density plasma chemical vapor deposition process that uses a low temperature (<460 °C) in situ germane/argon plasma surface preparation step for epitaxial growth of germanium on silicon. It is shown that the germane/argon plasma treatment sufficiently removes SiOx and carbon at the surface to enable germanium epitaxy. Finally, the use of this surface preparation step demonstrates an alternative way to produce germanium epitaxy at reduced temperatures, a key enabler for increased flexibility of integration with CMOS back-end-of-line fabrication

  15. Effect of hydrogen addition on the deposition of titanium nitride thin films in nitrogen added argon magnetron plasma

    Science.gov (United States)

    Saikia, P.; Bhuyan, H.; Diaz-Droguett, D. E.; Guzman, F.; Mändl, S.; Saikia, B. K.; Favre, M.; Maze, J. R.; Wyndham, E.

    2016-06-01

    The properties and performance of thin films deposited by plasma assisted processes are closely related to their manufacturing techniques and processes. The objective of the current study is to investigate the modification of plasma parameters occurring during hydrogen addition in N2  +  Ar magnetron plasma used for titanium nitride thin film deposition, and to correlate the measured properties of the deposited thin film with the bulk plasma parameters of the magnetron discharge. From the Langmuir probe measurements, it was observed that the addition of hydrogen led to a decrease of electron density from 8.6 to 6.2  ×  (1014 m‑3) and a corresponding increase of electron temperature from 6.30 to 6.74 eV. The optical emission spectroscopy study reveals that with addition of hydrogen, the density of argon ions decreases. The various positive ion species involving hydrogen are found to increase with increase of hydrogen partial pressure in the chamber. The thin films deposited were characterized using standard surface diagnostic tools such as x-ray photoelectron spectroscopy (XPS), secondary ion mass spectrometry (SIMS), x-ray diffraction (XRD), Raman spectroscopy (RS), scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). Although it was possible to deposit thin films of titanium nitride with hydrogen addition in nitrogen added argon magnetron plasma, the quality of the thin films deteriorates with higher hydrogen partial pressures.

  16. Quantification of water and plasma diagnosis for electrothermal vaporization-inductively coupled plasma-mass spectrometry: the use of argon and argide polyatomics as probing species

    International Nuclear Information System (INIS)

    The water content of the carrier flow originating from an electrothermal vaporization unit (ETV) attached to an inductively coupled plasma mass spectrometer was monitored by following the argon hydride ion (ArH+) at m/z=37. The goal was to measure the water expelled by the ETV at sample vaporization and evaluate the influence of this parameter on the ion-generation efficiency. Linear responses from the argon hydride were obtained when the water loading in the plasma injector flow was increased from 0 to 3.3 mg/min. Other argides and water-derived species (Ar+, Ar+2 and O+2) were also monitored simultaneously and the effects from operating parameters have been calculated for each species. The magnitude of these effects can eventually be used as diagnosis tools. It was also found that signals for zinc, copper, lead, antimony and arsenic were greatly influenced by slight variations in water loading at low water levels. These signal fluctuations are greatly attenuated and transients' shapes restored by convoluting each element transient with the ArH+ or Ar+2 curves that were recorded simultaneously. Envisioned applications that would benefit from a water-enhanced signal include spray electrothermal vaporization, direct sample insertion and laser ablation for inductively coupled plasma-mass spectrometry. The argon dimer Ar+2 seems more appropriate for making the correction since it provides a direct insight on the plasma temperature and provides a robust signal. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  17. Characterization of magnetically confined low-pressure plasmas produced by an electromagnetic field in argon-acetylene mixtures

    Science.gov (United States)

    Makdessi, G. Al; Margot, J.; Clergereaux, R.

    2016-10-01

    Dust particles formation was investigated in magnetically confined low-pressure plasma produced in argon-acetylene mixtures. The plasma characteristics were measured in order to identify the species involved in the dust particles formation. Their dependence on the operating conditions including magnetic field intensity, acetylene fraction in the gas mixture and operating pressure was examined. In contrast with noble gases, in the presence of acetylene, the electron temperature increases with the magnetic field intensity, indicating additional charged particles losses in the plasma. Indeed, in these conditions, larger hydrocarbon ions are produced leading to the formation of dust particles in the plasma volume. The observed dependence of positive ion mass distribution and density and relative negative ion density on the operating parameters suggests that the dust particles are formed through different pathways, where negative and positive ions are both involved in the nucleation.

  18. Pathogen inactivation in fresh frozen plasma using riboflavin and ultraviolet light: Effects on plasma proteins and coagulation factor VIII

    Directory of Open Access Journals (Sweden)

    Stanojković Zoran

    2011-01-01

    Full Text Available Background/Aim. Riboflavin (vitamin B2 activated by ultraviolet (UV light, produces active oxygen which damages cell membrane and prevents replication of the carrier of diseases (viruses, bacteria, protozoa in all blood products. The aim of this study was to establish the influence of the process of photo inactivation in pathogens using riboflavin and UV rays on the concentration of coagulation factor VIII:C (FVIII:C and proteins in plasma that were treated before freezing. Methods. The examination included 20 units of plasma, separated from whole blood donated by voluntary blood donors around 6 hours from the moment of collection. The units were pooled and separated in to two groups: one consisted of 10 control units and the other of 10 experimental units. Experimental units of the plasma were treated by riboflavin (35 mL and UV rays (6.24 J/mL, 265-370 nm on Mirasol aparature (Caridian BCT Biotechnologies, USA in approximate duration of 6 minutes. Furthermore, 35 mL of saline solution was added to the control plasma. One sample for examining was taken from the control plasma (KG and two residual were taken from experimental plasma after the addition of riboflavin either before (EG1 or post illumination (EG2. Results. Comparing the mean values of FVIII:C (% we noticed statistically significantly higher level in the EG1 group than in the EG2 group (65.00 ± 4.52 vs 63.20 ± 4.73; t = 4.323, p = 0.002, while between the KG and experimental groups (EG1 and EG2 there was no statistically significant difference in the concentration of FVIII:C. There was a statistically significant decrease of albumin concentration (g/L in the EG2 group comparing to the KG (33.35 ± 0.94 vs 31.94 ± 0.84; t = 3.534, p = 0.002, but there was no mentioned difference in albumin concentration between the KG and the EG1, so as between the EG1 and the EG2. Conclusion. Plasma inactivated by riboflavin and UV rays (Mirasol PRT sistem, Caridian BCT, USA keeps all the

  19. Study on structural, morphological and thermal properties of surface modified polyvinylchloride (PVC) film under air, argon and oxygen discharge plasma

    Science.gov (United States)

    Suganya, Arjunan; Shanmugavelayutham, Gurusamy; Serra Rodríguez, Carmen

    2016-09-01

    The effect of air, argon, oxygen DC glow discharge plasma on the polyvinylchloride (PVC) film synthesized by solution casting technique, were evaluated via changes in physio-chemical properties such as structural, morphological, crystalline, thermal properties. The PVC film was plasma treated as a function of exposure time and different plasma forming gases, while other operating parameters such as power and pressure remained constant at 100 W and 2 Pa respectively. The plasma treated PVC were characterized by static contact angle, ATR-FTIR, XPS, AFM and T-peel analysis. It was found that various gaseous plasma treatments have improved the polar components, surface roughness on the surface of PVC which was confirmed by XPS, AFM, resulting in highly enhanced wettability and adhesion. X-ray diffraction study showed that plasma treatment does not persuade considerable change, even though it vaguely induces the crystallinity. The thermal properties of plasma treated PVC were evaluated by Differential Scanning Calorimetry and it was observed that O2 plasma treatment gives higher glass transition temperature of 87.21 °C compared with the untreated one. The glass transition temperature slightly increased for Oxygen plasma treated material due to the presence of higher concentration of the polar functional groups on the PVC surface due to strong intramolecular bonding.

  20. Conversion of emitted dimethyl sulfide into eco-friendly species using low-temperature atmospheric argon micro-plasma system

    International Nuclear Information System (INIS)

    Highlights: ► Dimethyl sulfide (DMS) was fully decomposed by two-electrode Ar micro-plasma. ► The reaction of DMS/Ar resulted in forming solid compound and gaseous product. ► The C-, H- and S-containing solid compound was fixed on the quartz inner tube. ► The H2-, CS2-, and H2S-gaseous products were possibly recyclable and trapped. ► The dissociation mechanism and treatment efficiency of DMS were also discussed. - Abstract: A custom-made atmospheric argon micro-plasma system was employed to dissociate dimethyl sulfide (DMS) into a non-foul-smelling species. The proposed system takes the advantages of low energy requirement and non-thermal process with a constant flow rate at ambient condition. In the experiments, the compositions of DMS/argon plasma, the residual gaseous phases, and solid precipitates were respectively characterized using an optical emission spectrometer, various gas-phase analyzers, and X-ray photoemission spectroscopy. For 400 ppm DMS introduced into argon plasma with two pairs of electrodes (90 W), a complete decomposition of DMS was achieved; the DMS became converted into excited species such as C*, C2*, H*, and CH*. When gaseous products were taken away from the treatment area, the excited species tended to recombine and form stable compounds or species, which formed as solid particles and gaseous phases. The solid deposition was likely formed by the agglomeration of C-, H-, and S-containing species that became deposited on the quartz inner tube. For the residual gaseous phases, low-molecular-weight segments mostly recombined into relatively thermodynamic stable species, such as hydrogen, hydrogen sulfide, and carbon disulfide. The dissociation mechanism and treatment efficiency are discussed, and a treatment of converting DMS into H2-, CS2-, and H2S-dominant by-products is proposed.

  1. Single-shot Thomson scattering on argon plasmas created by the Microwave Plasma Torch; evidence for a new plasma class

    Science.gov (United States)

    van der Mullen, J. J. A. M.; van de Sande, M. J.; de Vries, N.; Broks, B.; Iordanova, E.; Gamero, A.; Torres, J.; Sola, A.

    2007-10-01

    To determine the fine-structure size of plasmas created by a Microwave Plasma Torch (MPT), single-shot Thomson scattering (TS) measurements were performed. The aim was to find a solution for the long-standing discrepancy between experiments and Global Plasma Models (GPMs). Since these GPMs are based on the assumption that (ambipolar) diffusion is the main loss process for charged particles, the diffusion length and thus the fine-structure size should be known with high precision before an appropriate theory-experiment comparison can be carried out. In order to avoid the effect of blurring, which is created during the accumulation of multi-shot TS signals and which obscures the fine-structures, single-shot measurements are indispensable to determine the diffusion length. The results of the present study reveal that the impression created by multi-shot TS that MPT plasmas resemble stable cones is not (always) correct; instead it is found that the plasmas we investigated are tiny filaments that rotate on the mantle of a virtual cone. However, the fine-structure, especially the thickness, of these filaments is not substantially smaller than that of the virtual cone. By applying the theory-experiment comparison to the filament we found that the disagreement is even worse than what we found for the cone. It is therefore inevitable to conclude that the main proposition of the GPM is incorrect. Apparently the plasma is not diffusive in nature; that is, the main loss process of charged particles is not provided by diffusion but by local chemistry. Swirling in a cool nitrogen-containing environment favors the production of molecular ions such as Ar 2+ and N 2+ inside the plasma filament. The destruction of these molecular ions leads to recombination frequencies that are more than a factor 100 larger than what ambipolar diffusion can provide. Thus we are dealing with another plasma class and it is useful to divide plasmas into diffusive and reactive plasmas. The well

  2. Coagulation Factor and Hemostatic Protein Content of Canine Plasma after Storage of Whole Blood at Ambient Temperature

    OpenAIRE

    Walton, J.E.; Hale, A. S.; Brooks, M. B.; Boag, A.K.; Barnett, W.; Dean, R.

    2014-01-01

    Background Standard practice in canine blood banking is to produce fresh frozen plasma (FFP) by separating and freezing plasma produced from blood within 8 hours of collection. Within canine blood donation programs, this can limit the number of units collected. Hypothesis/Objectives The aim was to compare the coagulation factor and hemostatic protein content (CF&HPC) of plasma produced from blood stored at ambient temperature for 8, 12, and 24 hours. Another aim was to compare the CF&HPC betw...

  3. Evaluation of bone response to synthetic bone grafting material treated with argon-based atmospheric pressure plasma

    Energy Technology Data Exchange (ETDEWEB)

    Beutel, Bryan G., E-mail: bryanbeutel@gmail.com; Danna, Natalie R.; Gangolli, Riddhi; Granato, Rodrigo; Manne, Lakshmiprada; Tovar, Nick; Coelho, Paulo G.

    2014-12-01

    Bone graft materials are utilized to stimulate healing of bone defects or enhance osseointegration of implants. In order to augment these capabilities, various surface modification techniques, including atmospheric pressure plasma (APP) surface treatment, have been developed. This in vivo study sought to assess the effect of APP surface treatment on degradation and osseointegration of Synthograft™, a beta-tricalcium phosphate (β-TCP) synthetic bone graft. The experimental (APP-treated) grafts were subjected to APP treatment with argon for a period of 60 s. Physicochemical characterization was performed by environmental scanning electron microscopy, surface energy (SE), and x-ray photoelectron spectroscopy analyses both before and after APP treatment. Two APP-treated and two untreated grafts were surgically implanted into four critical-size calvarial defects in each of ten New Zealand white rabbits. The defect samples were explanted after four weeks, underwent histological analysis, and the percentages of bone, soft tissue, and remaining graft material were quantified by image thresholding. Material characterization showed no differences in particle surface morphology and that the APP-treated group presented significantly higher SE along with higher amounts of the base material chemical elements on it surface. Review of defect composition showed that APP treatment did not increase bone formation or reduce the amount of soft tissue filling the defect when compared to untreated material. Histologic cross-sections demonstrated osteoblastic cell lines, osteoid deposition, and neovascularization in both groups. Ultimately, argon-based APP treatment did not enhance the osseointegration or degradation of the β-TCP graft. Future investigations should evaluate the utility of gases other than argon to enhance osseointegration through APP treatment. - Highlights: • Degradation/osseointegration of bone graft treated with argon-based APP is studied. • APP treatment did

  4. Towards the reduction of matrix effects in inductively coupled plasma mass spectrometry without compromising detection limits: The use of argon-nitrogen mixed-gas plasma

    International Nuclear Information System (INIS)

    The multivariate optimization of a mixed-gas plasma was conducted in an attempt to find conditions minimizing matrix effects without sacrificing the detection limits that are observed with an all argon plasma optimized for maximum sensitivity in inductively coupled plasma mass spectrometry. Compared to the latter, where 49.1 ± 7.1% (n = 17) analyte signal suppression resulted in the presence of 0.1 M Na, 3.8 ± 3.2% suppression (and 2.8 ± 2.1% enhancement in some cases) was observed in the optimized mixed-gas plasma with 0.13% v/v N2 in the plasma gas and 0.11% in the central channel as a sheath gas around the nebulizer gas flow. Furthermore, improved detection limits were observed for Al, Co, Pd, and V with the optimized mixed-gas plasma compared to an argon plasma at maximum sensitivity. The robustness of this mixed-gas plasma was further demonstrated through the accurate determination of U and Mo in NASS-5 seawater certified reference material using a simple external calibration, without matrix-matching or internal standardization. Indeed, the result obtained for Mo (9.1 ± 1.9 μg/L) was within the 95% confidence interval of the certified value of 9.6 ± 1.0 μg/L, while that obtained for U (3.0 ± 0.2 μg/L) was close to the information value of 2.6 μg/L. Spatial profiling results suggest better energy transfer between the toroidal zone and the central channel in the mixed-gas plasma.

  5. A hybrid model of radio frequency biased inductively coupled plasma discharges: description of model and experimental validation in argon

    Science.gov (United States)

    Wen, De-Qi; Liu, Wei; Gao, Fei; Lieberman, M. A.; Wang, You-Nian

    2016-08-01

    A hybrid model, i.e. a global model coupled bidirectionally with a parallel Monte-Carlo collision (MCC) sheath model, is developed to investigate an inductively coupled discharge with a bias source. This hybrid model can self-consistently reveal the interaction between the bulk plasma and the radio frequency (rf) bias sheath. More specifically, the plasma parameters affecting characteristics of rf bias sheath (sheath length and self-bias) are calculated by a global model and the effect of the rf bias sheath on the bulk plasma is determined by the voltage drop of the rf bias sheath. Moreover, specific numbers of ions are tracked in the rf bias sheath and ultimately the ion energy distribution function (IEDF) incident on the bias electrode is obtained. To validate this model, both bulk plasma density and IEDF on the bias electrode in an argon discharge are compared with experimental measurements, and a good agreement is obtained. The advantage of this model is that it can quickly calculate the bulk plasma density and IEDF on the bias electrode, which are of practical interest in industrial plasma processing, and the model could be easily extended to serve for industrial gases.

  6. Broadening of the Spectral Atomic Lines Analysis in High Density Argon Corona Plasma by Using Voigt Profile

    Science.gov (United States)

    Nur, M.; Bonifaci, N.; Denat, A.; Atrazhev, V. M.

    2015-06-01

    Studies of spectrum emission from high density argon plasma corona has been done. The analysis of the boardening of spectral atomic lines of Ar-I profile has been curried out by using an empirical approximation based on a Voigt profile. Full-width at half-maximum (FWHM) of the spectral-lines of 763.5 nm has been determined from atmospheric pressure until liquid state. The study liquid argon was curried out in a variation of temperature from K to 151.2 K and hydrostatics pressure from 2.1 MPa to 6.4 MPa. These pressure gives the densities N∞ (i.e. density very far from ionization zone) a variation from 1.08 1022 to 2.11 1022 cm-3. FWHM of Voigt approximation (Wv) of the line 763,5 nm of 'Ar I for: the emission lamp very low pressure (Wv = 0,160 nm) and our corona discharge at a pressure of MPa (Wv = 0,67 nm) and at a pressure of 9,5 MPa (Wv = 1,16 nm). In gas, corona plasma has been generated from 0.1 MPa to 9.5 MPa. We found that the broadening spectral line increase by increasing densities both for. the spectral-lines of 763.5 nm and 696.5 nm. We concluded that broadening of spectrum cause of Van der Waals force.

  7. Fresh frozen plasma in the pediatric age group and in congenital coagulation factor deficiency.

    Science.gov (United States)

    Muntean, Wolfgang

    2002-10-31

    Generally, the rules of good practice in transfusion medicine apply also to the pediatric age group. However, the frequency of specific diseases that might necessitate the administration of fresh frozen plasma (FFP) differs from that in adults. Physiologic differences to the later age exist in the neonatal period and in young infants, especially with respect to the hemostatic system, that must be recognized when considering administration of FFP. The plasma levels of many procoagulant factors and important anticoagulants are lower in neonates than in other age groups. Despite these findings, healthy neonates show no easy bruising, no increased bleeding during surgery, and excellent wound healing. The same discrepancy obtains between in vitro and clinical findings with primary hemostasis in neonates. The good primary hemostasis in neonates despite poor in vitro platelet function seems to be due mainly to a very high von Willebrand factor and the presence of more high-multimeric subunits of von Willebrand factor than later in life. We must assume that these particular plasma levels of procoagulant and anticoagulant proteins are essential for the correct function of neonatal hemostasis. Evidence that the hemostatic system of neonates works best with physiologic concentrations of procoagulants and anticoagulants can also be inferred from studies where the administration of clotting factor concentrates gave poor results.Since healthy neonates and young infants have excellent hemostasis, there is absolutely no indication to 'correct' these values to adult's norms prior to invasive procedures by administering FFP. Indications for FFP, met more frequently in the pediatric age group than later in life, are exchange transfusion and extracorporeal membrane oxygenation. Indications applying equally to adults are other extracorporeal life support systems, disseminated intravascular coagulation, hepatic coagulopathy, and 'complex unclear coagulopathies'. In congenital clotting

  8. Determination of dissolved boron in fresh, estuarine, and geothermal waters by d.c. argon-plasma emission spectrometry

    Science.gov (United States)

    Ball, J.W.; Thompson, J.M.; Jenne, E.A.

    1978-01-01

    A d.c. argon-plasma emission spectrometer is used to determine dissolved boron in natural (fresh and estuarine) water samples. Concentrations ranged from 0.02 to 250 mg l-1. The emission-concentration function is linear from 0.02 to 1000 mg l-1. Achievement of a relative standard deviation of ??? 3% requires frequent restandardization to offset sensitivity changes. Dilution may be necessary to overcome high and variable electron density caused by differences in alkali-metal content and to avoid quenching of the plasma by high solute concentrations of sodium and other easily ionized elements. The proposed method was tested against a reference method and found to be more sensitive, equally or more precise and accurate, less subject to interferences, with a wider linear analytical range than the carmine method. Analyses of standard reference samples yielded results in all cases within one standard deviation of the means. ?? 1978.

  9. Simulations and Measurement of Electron Energy and Effective Electron Temperature of Nanosecond Pulsed Argon Plasma%Simulations and Measurement of Electron Energy and Effective Electron Temperature of Nanosecond Pulsed Argon Plasma

    Institute of Scientific and Technical Information of China (English)

    闻雪晴; 信裕; 冯春雷; 丁洪斌

    2012-01-01

    The behavior of argon plasma driven by nanosecond pulsed plasma in a low-pressure plasma reactor is investigated using a global model, and the results are compared with the experimental measurements. The time evolution of plasma density and the electron energy probability function are calculated by solving the energy balance and Boltzmann equations. During and shortly after the discharge pulse, the electron energy probability function can be represented by a bi-Maxwellian distribution, indicating two energy groups of electrons. According to the effective electron temperature calculation, we find that there are more high-energy electrons that play an important role in the excitation and ionization processes than low-energy electrons. The effective electron temperature is also measured via optical emission spectroscopy to evaluate the simulation model. In the comparison, the simulation results are found to be in agreement with the measure- ments. Furthermore, variations of the effective electron temperature are presented versus other discharge parameters, such as pulse width time, pulse rise time and gas pressure.

  10. Safety of plasma-derived protein C for treating disseminated intravascular coagulation in adult patients with active cancer.

    Science.gov (United States)

    Malato, Alessandra; Saccullo, Giorgia; Coco, Lucio Lo; Caracciolo, Clementina; Raso, Simona; Santoro, Marco; Zammit, Valentina; Siragusa, Sergio

    2012-02-01

    Cancer-related disseminated intravascular coagulation (DIC) is a life-threatening condition for which no effective treatment is currently available. Protein C (PC), a modulator of coagulation as well as the inflammatory system, has been successfully tested (in its activated recombinant form [a-rPC]) in sepsis-related coagulopathy, but with an increased risk for major bleeding. Plasma-derived PC (pd-PC) is more suitable than a-rPC in patients at high risk from bleeding due to its self-limiting process. We carried out a single-arm study evaluating the role of pd-PC in adult cancer patients with overt DIC. Over a period of 3 years, we treated 19 patients with overt DIC and a PC plasma concentration coagulation, haematological tests, and the DIC score were recorded after 12, 24, 48 hr, 7 and 10 days, while clinical outcomes (bleeding, thrombosis and mortality) were recorded up to 28 days. Within 48 hr of starting pd-PC therapy, laboratory tests as well as the DIC score improved in all patients. At 28-days follow-up, no bleeding or thrombosis was observed. This is the first study to investigate the use of pd- PC for treatment of cancer-related overt DIC.

  11. Antibacterial Activity of Cold Atmospheric Pressure Argon Plasma against 78 Genetically Different (mecA, luk-P, agr or Capsular Polysaccharide Type) Staphylococcus aureus Strains.

    Science.gov (United States)

    Matthes, Rutger; Lührman, Anne; Holtfreter, Silva; Kolata, Julia; Radke, Dörte; Hübner, Nils-Olaf; Assadian, Ojan; Kramer, Axel

    2016-01-01

    Previous studies on the antimicrobial activity of cold atmospheric pressure argon plasma showed varying effects against mecA+ or mecA-Staphylococcus aureus strains. This observation may have important clinical and epidemiological implications. Here, the antibacterial activity of argon plasma was investigated against 78 genetically different S. aureus strains, stratified by mecA, luk-P, agr1-4, or the cell wall capsule polysaccharide types 5 and 8. kINPen09® served as the plasma source for all experiments. On agar plates, mecA+luk-P-S. aureus strains showed a decreased susceptibility against plasma compared to other S. aureus strains. This study underlines the high complexity of microbial defence against antimicrobial treatment and confirms a previously reported strain-dependent susceptibility of S. aureus to plasma treatment.

  12. Permeation barrier performance of Hot Wire-CVD grown silicon-nitride films treated by argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Majee, S., E-mail: subimal.majee@polytechnique.edu [Laboratoire de Physique des Interfaces et des Couches Minces, CNRS UMR 7647, Ecole polytechnique, 91128 Palaiseau (France); Cerqueira, M.F. [Centro de Física, Universidade do Minho, 4710-057 Braga (Portugal); Tondelier, D.; Vanel, J.C. [Laboratoire de Physique des Interfaces et des Couches Minces, CNRS UMR 7647, Ecole polytechnique, 91128 Palaiseau (France); Geffroy, B. [Laboratoire de Physique des Interfaces et des Couches Minces, CNRS UMR 7647, Ecole polytechnique, 91128 Palaiseau (France); Laboratoire de Chimie des Surfaces et Interfaces, IRAMIS/SPCSI CEA Saclay, 91191 Gif-sur-Yvette (France); Bonnassieux, Y. [Laboratoire de Physique des Interfaces et des Couches Minces, CNRS UMR 7647, Ecole polytechnique, 91128 Palaiseau (France); Alpuim, P. [Centro de Física, Universidade do Minho, 4710-057 Braga (Portugal); INL–International Iberian Nanotechnology Laboratory, 4715-330 Braga (Portugal); Bourée, J.E., E-mail: jean-eric.bouree@polytechnique.edu [Laboratoire de Physique des Interfaces et des Couches Minces, CNRS UMR 7647, Ecole polytechnique, 91128 Palaiseau (France)

    2015-01-30

    In this work SiN{sub x} thin films have been deposited by Hot-Wire Chemical Vapor Deposition (HW-CVD) technique to be used as encapsulation barriers for flexible organic electronic devices fabricated on polyethylene terephthalate (PET) substrates. First results of SiN{sub x} multilayers stacked and stacks of SiN{sub x} single-layers (50 nm each) separated by an Ar-plasma surface treatment are reported. The encapsulation barrier properties of these different multilayers are assessed using the electrical calcium degradation test by monitoring changes in the electrical conductance of encapsulated Ca sensors with time. The water vapor transmission rate is found to be slightly minimized (7 × 10{sup −3} g/m{sup 2}day) for stacked SiN{sub x} single-layers exposed to argon plasma treatment during a short time (2 min) as compared to that for stacked SiN{sub x} single-layers without Ar plasma treatment. - Highlights: • SiN{sub x} films are grown using HW-CVD to be used as permeation barrier layer. • Ar plasma treatment is made between two successive SiN{sub x} films. • Electrical calcium degradation test is used to evaluate the WVTR values. • Lowest WVTR value of ~ 7 × 10{sup -3} g/m{sup 2}.day is reported.

  13. Permeation barrier performance of Hot Wire-CVD grown silicon-nitride films treated by argon plasma

    International Nuclear Information System (INIS)

    In this work SiNx thin films have been deposited by Hot-Wire Chemical Vapor Deposition (HW-CVD) technique to be used as encapsulation barriers for flexible organic electronic devices fabricated on polyethylene terephthalate (PET) substrates. First results of SiNx multilayers stacked and stacks of SiNx single-layers (50 nm each) separated by an Ar-plasma surface treatment are reported. The encapsulation barrier properties of these different multilayers are assessed using the electrical calcium degradation test by monitoring changes in the electrical conductance of encapsulated Ca sensors with time. The water vapor transmission rate is found to be slightly minimized (7 × 10−3 g/m2day) for stacked SiNx single-layers exposed to argon plasma treatment during a short time (2 min) as compared to that for stacked SiNx single-layers without Ar plasma treatment. - Highlights: • SiNx films are grown using HW-CVD to be used as permeation barrier layer. • Ar plasma treatment is made between two successive SiNx films. • Electrical calcium degradation test is used to evaluate the WVTR values. • Lowest WVTR value of ~ 7 × 10-3 g/m2.day is reported

  14. Determining the effect of freezing on coagulation testing: comparison of results between fresh and once frozen-thawed plasma.

    Science.gov (United States)

    Gosselin, Robert C; Dwyre, Denis W

    2015-01-01

    The accuracy of the results from coagulation testing can be affected by numerous preanalytic and analytic variables including the stability of the citrated sample at room temperature. Samples not tested within 2-4 h of collection should be processed and frozen for later analysis. As limited data exist about the impact of freezing samples on coagulation testing, we sought to evaluate the effect of freezing on coagulation testing. Plasma samples into 3.2% sodium citrate tubes, centrifuged to yield platelet-poor plasma, were evaluated for prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen, D-dimer, antithrombin (AT) activity, factors V, VII, VIII, IX, lupus anticoagulant and anti-Xa measurements for both unfractionated and low-molecular-weight heparins. Samples were then frozen at -70°C for at least 1 week and testing was repeated using the same lot of material. All tests strongly correlated (R > 0.85) between fresh and frozen sample results. Using paired t test analysis, significant differences between fresh and frozen tested plasma existed for PT, APTT, factors V, VIII and AT. Significant differences existed between fresh and frozen lupus anticoagulant ratios (lupus anticoagulant screen but not lupus anticoagulant confirm), and single centrifugation process underestimated the presence of lupus anticoagulant as compared to double centrifugation processing. Freezing significantly affects the results for PT, APTT, factors V and VIII activity, and AT activity, although these differences were not considered to be clinically significant. Double centrifugation is required for accurate lupus anticoagulant testing, regardless of whether platelet-poor plasma is achieved with single centrifugation.

  15. Study of emission of a volume nanosecond discharge plasma in xenon, krypton and argon at high pressures

    International Nuclear Information System (INIS)

    The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude-time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ∼45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ∼130 ns. (laser applications and other topics in quantum electronics)

  16. Dynamics of self-compressed argon and helium plasma streams in the MPC facility

    Science.gov (United States)

    Ladygina, M. S.; Marchenko, A. K.; Solyakov, D. G.; Petrov, Yu V.; Makhlaj, V. A.; Yeliseyev, D. V.; Garkusha, I. E.; Cherednichenko, T. N.

    2016-07-01

    The results of experimental investigations on self-compressed plasma streams and compression zone formation are presented for varied mass flow rate and initial concentrations of particles of working gas that depend on initial pressure. Experiments were carried out in the Magnetoplasma Compressor (MPC) facility. Space–time distributions of the electric current and electron density in the plasma stream compression region were measured under different experimental conditions. High-speed images of plasma stream dynamics in the MPC accelerating channel with a high temporal resolution were also obtained for different initial pressures. The experimental results show a strong dependence of plasma stream parameters and compression zone location on the initial gas concentration. The maximum electron density is obtained in the range of Ne = (1 ÷ 5) × 1018 cm‑3. Plasma streams have a good radial symmetry under all experimental conditions. The distributions of plasma parameters along the plasma stream flows are discussed.

  17. Heat and momentum transfer from an atmospheric argon hydrogen plasma jet to spherical particles

    International Nuclear Information System (INIS)

    In this thesis the author describes the energy and momentum transfer from the plasma jet to the spray particles. This is done both experimentally and theoretically. Also the internal energy process of the recombining plasma is discussed. All elastic and inelastic collisional and radiative processes, as well as transport effects within the plasma are considered. In the next section, the so called passive spectroscopy is treated. It describes the diagnostics of electron density and temperature measurement, as well as the investigation on heat content of the particles. Spatially resolved electron density and temperature profiles are presented. Next, the active spectroscopy, i.e. the laser Doppler anemometer is dealt with. With this diagnostic, axial spray-particle velocities inside the plasma jet were determined. The author also presents heat and momentum transfer modelling of the plasma, related to the plasma particle interaction. Finally, a one dimensional model verification is made, using the experimentally determined particle velocity and plasma temperature profiles. (Auth.)

  18. Determination of boron in silicon-bearing alloys, steel, and other alloys by pyrohydrolysis and inductively-coupled argon-plasma spectroscopy.

    Science.gov (United States)

    Hamner, R M; De'aeth, L A

    1980-06-01

    Boron is quantitatively separated from silicon-bearing and other inorganic materials by pyrohydrolysis. Microgram amounts of boron are separated by passing oxygen-saturated steam over a sample mixed with vanadium oxide and copper oxide. The distillate is collected in dilute potassium hydroxide solution and determined by inductively-coupled argon-plasma spectroscopy. PMID:18962720

  19. Optical emission spectroscopy for quantification of ultraviolet radiations and biocide active species in microwave argon plasma jet at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Wattieaux, G., E-mail: gaetan.wattieaux@laplace.univ-tlse.fr; Yousfi, M.; Merbahi, N.

    2013-11-01

    This work deals with absorption and mainly emission spectrometry of a microwave induced surfatron plasma jet launched in ambient air and using an Argon flow carrier gas. The Ar flow rate varies between 1 and 3 L/min and the microwave power between 40 and 60 W. The analysis of the various spectra has led to the determination of the ozone and atomic oxygen concentrations, ultraviolet (UV) irradiance separating UVA, UVB and UVC, gas temperature, plasma electron density and excitation temperature. Most of these diagnostics are spatially resolved along the plasma jet axis. It is shown more particularly that rotational temperature obtained from OH(A-X) spectra ranges between 800 K to 1000 K while the apparent temperature of the plasma jet remains lower than about 325 K which is compatible with biocide treatment without significant thermal effect. The electron density reaches 1.2 × 10{sup 14} cm{sup −3}, the excitation temperature is about 4000 K, the UVC radiation represents only 5% of the UV radiations emitted by the device, the ozone concentration is found to reach 88 ± 27 ppm in the downstream part of the plasma jet at a distance of 30 mm away from the quartz tube outlet of the surfatron and the atomic oxygen concentration lies between 10 and 80 ppm up to a distance of 20 mm away from the quartz tube outlet. Ozone is identified as the main germicidal active species produced by the device since its concentration is in accordance with bacteria inactivation durations usually reported using such plasma devices. Human health hazard assessment is carried out all along this study since simple solutions are reminded to respect safety standards for exposures to ozone and microwave leakage. In this study, an air extraction unit is used and a Faraday cage is set around the quartz tube of the surfatron and the plasma jet. These solutions should be adopted by users of microwave induced plasma in open air conditions because according to the literature, this is not often the

  20. Comparison between helium and argon plasma jets on improving the hydrophilic property of PMMA surface

    Science.gov (United States)

    Wang, Ruixue; Shen, Yuan; Zhang, Cheng; Yan, Ping; Shao, Tao

    2016-03-01

    In this paper, a plasma jet driven by an in-house developed microsecond pulse is used for polymethyl methacrylate (PMMA) surface modification. The hydrophilic modification effects of He and Ar plasma jets are compared under the same condition. The He and Ar plasma jets are characterized by optical emission spectrometer (OES). Water contact angle (WCA) measurement is used to evaluate the wettability of PMMA samples. The evolution on morphology and chemical composition of PMMA before and after plasma treatment are also analyzed. The OES results demonstrate that He plasma is composed with higher intensities of reactive species, like OH, O, N2 and N2+ than that of Ar plasma and show a better modification effect. In addition, it is observed that the surface roughness and oxygen-containing groups like Csbnd O/Csbnd OH and Odbnd Csbnd O increase on the PMMA surface after plasma treatment, which are responsible for the hydrophilic modification. During the storage, the WCA of each sample increases gradually for both He and Ar plasma treatments. The He plasma treated PMMA also shows a slower aging effect than that of Ar plasma treated PMMA.

  1. COMPARATIVE ANALISYS OF COLD PLASMA COAGULATION AND SUTURING EFFECTS ON LIVER STRUCTURE IN THE EARLY PERIOD AFTER ATYPICAL RESECTION

    Directory of Open Access Journals (Sweden)

    Ye. V. Semichev

    2015-01-01

    Full Text Available The research was performed on 45 laboratory rats to make a comparative analysis of morphofunctional changes of rats' liver in early period after resection of left lobe and hemostasis by suturing and cold plasma. There were 3 experimental groups: 5 intact animals (control group and 5 animals in each group after liver resection and suturing and liver resection and cold plasma coagulation. Material for research was taken on the 3rd, 7th, 14th, 30th day after surgery. Surgery is resection of liver left lobe, suturing or cold plasma coagulation. The biochemical control blood (glucose, ALT, AST, thymol test, total bilirubin, direct, alkaline phosphatase, total protein, urea, α-amylase, CRP, fibrinogen, aPTT, PTT, INR, morphological study of rat liver were performed. Analysis of biochemical markers reveals, that such indices as AST, α-amylase, alkaline phosphatase, fibrinogen, thymol test are increased in early period in experimental groups relatively the control group. A slight increase in the level of α-amylase is remained on the 30th day, this indicator in plasma group was less than indicator in suturing group. Other indices are normal. Analysis of morphological markers reveals, that such indices as specific volume of hepatocytes with signs of degeneration, the number of cells with necrotic changes in 1 mm2, infiltrate density in 1 mm2 and the specific volume of the connective tissue are increased, and then are gradually reduced to 30 days. Specific volume of binucleated hepatocytes in early period is reduced, and by the 30th day is increased. Indicators of liver damage in plasma group were statistically less than indicators in suturing group at all test points. It was found that pathological effects caused by the action of cold plasma were considerably lower than the effects produced by the suturing.

  2. Modification of acidity of Mo-Fe/HZSM-5 zeolite via argon plasma treatment

    Institute of Scientific and Technical Information of China (English)

    Xinli ZHU; Kailu YU; Dangguo CHENG; Yueping ZHANG; Qing XIA; Changjun LIU

    2008-01-01

    The NH3-TPD characterization was conducted to confirm that the acidity of Mo-Fe/HZSM-5 zeolite could be selectively modified via the glow discharge plasma treatment. The plasma catalyst treatment could totally change the distribution of aromatic products with higher methane conversion compared to the untreated catalyst. Some polycyclic aromatics such as anthracene, pyrene and phenanthrene were also produced over the plasma treated catalyst, in addition to benzene, toluene and naphthalene, which were normally obtained over the untreated catalyst.

  3. Plasma diagnostics of the SIMPA Ecr ion source by X-ray spectroscopy, Collisions of H-like Neon ions with Argon clusters

    International Nuclear Information System (INIS)

    The first part of this thesis is devoted to the SIMPA ECR ion source characterization, first, I explored the ion source's capacities on the point of view of extracted currents for three elements, argon, krypton and neon. By analyzing the Bremsstrahlung spectra, I determined the electronic temperature in the plasma and the electronic and ionic densities. In a second time, I recorded high resolution X-spectra of argon and krypton plasma's. By taking into account the principal mechanisms of production of a K hole in the ions inside the plasma, I determined the ionic densities of the high charge states of argon. Lastly, I highlighted a correlation between the ions charge states densities with the intensities of extracted currents. The second part of the thesis is devoted to Ne9+- argon clusters collisions. First, I presented simple and effective theoretical models allowing to describe the phenomena occurring during a collision, from the point of view of the projectile. I carried out a simulation for a collision of an ion Ne9+ with an argon cluster of a given size, which has enabled us to know the energy levels populated during the electronic capture and to follow the number of electrons in each projectile shell. Lastly, I presented the first results of a collision between a Ne9+ beam and argon clusters. These results, have enabled me by using projectile X-ray spectroscopy during the ions-clusters collision, to evidence a strong clustering of targets atoms and to highlight an electronic multi-capture in the projectile ion excited states. (author)

  4. Electron properties and air mixing in radio frequency driven argon plasma jets at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Gessel, Bram van; Bruggeman, Peter [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Brandenburg, Ronny [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Leibniz Institute for Plasma Science and Technology (INP Greifswald), Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany)

    2013-08-05

    A time modulated radio frequency (RF) plasma jet operated with an Ar mixture is investigated by measuring the electron density and electron temperature using Thomson scattering. The measurements have been performed spatially resolved for two different electrode configurations and as a function of the plasma dissipated power and air concentration admixed to the Ar. Time resolved measurements of electron densities and temperatures during the RF cycle and after plasma power switch-off are presented. Furthermore, the influence of the plasma on the air entrainment into the effluent is studied using Raman scattering.

  5. Reactivity of water vapor in an atmospheric argon flowing post-discharge plasma torch

    CERN Document Server

    Collette, S; Reniers, F

    2016-01-01

    The reactivity of water vapor introduced in the flowing post-discharge of an RF atmospheric plasma torch is investigated through electrical characterization, optical emission spectroscopy and mass spectrometry measurements. Due to the technical features of the plasma torch, the post-discharge can be considered as divided into two regions: an inner region (inside the plasma torch device) where the water vapor is injected and an outer region which directly interacts with the ambient air. The main reactions induced by the injection of water vapor are identified as well as those indicative of the influence of the ambient air. Plausible pathways allowing the production of H, OH, O radicals and H2O2 are discussed as well as reactions potentially responsible for inhomogeneities and for a low DC current measured in the flowing post-discharge. Keywords: atmospheric post-discharge, H2O plasma reactivity, RF plasma torch

  6. Argon-dominated plasma beam generated by filtered vacuum arc and its substrate etching

    International Nuclear Information System (INIS)

    A new technique to etch a substrate as a pre-treatment prior to functional film deposition was developed using a filtered vacuum arc plasma. An Ar-dominated plasma beam was generated from filtered carbon arc plasma by introducing appropriate flow rate of Ar gas in a T-shape filtered arc deposition (T-FAD) system. The radiation spectra emitted from the filtered plasma beam in front of a substrate table were measured. The substrate was etched by the Ar-dominated plasma beam. The principal results are summarized as follows. At a high flow rate of Ar gas (50 ml/min), when the bias was applied to the substrate, the plasma was attracted toward the substrate table and the substrate was well etched without film formation on the substrate. Super hard alloy (WC), bearing steel (SUJ2), and Si wafer were etched by the Ar-dominated plasma beam. The etching rate was dependent on the kind of substrate. The roughness of the substrate increased, when the etching rate was high. A pulse bias etched the substrate without roughening the substrate surface excessively.

  7. Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

    Science.gov (United States)

    Cristofolini, Andrea; Neretti, Gabriele; Borghi, Carlo A.

    2012-08-01

    This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of Hα and the Hβ lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

  8. Acetylene - Argon Plasmas Measured at a Biased Substrate Electrode for Diamond-Like Carbon Deposition. Part 2: Ion Energy Distributions

    CERN Document Server

    Baby, A; Lemoine, P; Maguire, P D

    2008-01-01

    Ion energy distributions have been determined at the rf-bias electrode in an inductively-coupled acetylene-argon plasma for various substrate bias voltages and frequencies under conditions suitable for film deposition. These are compared with those obtained at the grounded wall of a capacitively coupled plasma. In the former, for pressures up to 25 mTorr, the IEDs exhibit bimodal structures with peak separation values that follow the expected dependence on voltage and frequency. At higher pressures, 120 mTorr, the bimodal structure is replaced by a single peak. For all conditions, the dominant ion is Ar+ or ArH+ despite a set C2H2:Ar flow ratio of 2:1, and this can be attributed to the high electron dissociation of the parent molecule. Diamond-like carbon films indicate a peak hardness at an ion energy of around 90 eV and a very sharp fall in hardness is noted beyond this value. This is similar to the observed bombardment energy relationship for sp3 bond formation in hydrogen-free tetragonal amorphous carbon ...

  9. Modeling Argon Plasma Excimer Characteristics near a Dielectric Surface in Miniaturized Volumes

    Science.gov (United States)

    Farahat, Ashraf; Ramadan, Emad

    2014-10-01

    We computationally model plasma -neutral gas dynamics in a miniaturized microthruster encloses Ar and contains a dielectric material sandwiched between two metal plates using a two dimensional plasma model. Spatial and temporal plasma properties are investigated by solving the Poisson equation with the conservation equations of charged and excited neutral plasma species. We find the microthruster properties to depend on small changes in the secondary electron emission coefficient that could result from dielectric erosion and aging. The changes also affect the electrohydrodynamic force produced when we use the microthruster to generate thrust for small spacecrafts. The electrohydrodynamic force is calculated and found to be significant in the sheath area near the dielectric layer and is found to affect gas flow dynamics including the Ar excimer formation and density. The plasma-neutral gas momentum exchange is significant in affecting gas flow dynamics and in the formation of excimer species in addition to affecting the UV and visible emission characteristics of the device. The authors would like to acknowledge the support provided by the Deanship of Scientific Research (DSR) at the King Fahd University of Petroleum & Minerals (KFUPM) for funding this work through Project No. IN111026.

  10. Broadband microwave characteristics of a novel coaxial gridded hollow cathode argon plasma

    Science.gov (United States)

    Gao, Ruilin; Yuan, Chengxun; Li, Hui; Jia, Jieshu; Zhou, Zhong-Xiang; Wang, Ying; Wang, Xiaoou; Wu, Jian

    2016-08-01

    The interaction between microwave and large area plasma is crucially important for space communication. Gas pressure, input power, and plasma volume are critical to both the microwave electromagnetic wave phase shift and electron density. This paper presents a novel type of large coaxial gridded hollow cathode plasma having a 50 cm diameter and a 40 cm thickness. Microwave characteristics are studied using a microwave measurement system that includes two broadband antennae in the range from 2 GHz to 18 GHz. The phase shift under varying gas pressure and input power is shown. In addition, the electron density ne, which varies from 1.2 × 1016 m-3 to 8.7 × 1016 m-3 under different discharge conditions, is diagnosed by the microwave system. The measured results accord well with those acquired by Langmuir Probe measurement and show that the microwave properties in the large volume hollow cathode discharge significantly depend on the input power and gas pressure.

  11. The effect of argon plasma treatment on the permeation barrier properties of silicon nitride layers

    OpenAIRE

    Majee, Subimal; Cerqueira, M. F.; Tondelier, D.; Geffroy, B.; Bonnassieux, Y.; Alpuim, P.; Bourée, J. E.

    2013-01-01

    In this work we produce and study silicon nitride (SiNx) thin films deposited by Hot Wire Chemical Vapor Depo- sition (HW-CVD) to be used as encapsulation barriers for flexible organic photovoltaic cells fabricated on poly- ethylene terephthalate (PET) substrates in order to increase their shelf lifetime. We report on the results of SiNx double-layers and on the equivalent double-layer stack where an Ar-plasma surface treatment was performed on the first SiNx layer. The Ar-plasma treatment ma...

  12. X-ray Emission from Argon Plasma Focus Contaminated with Copper Impurities in AECS PF-2 Using Five Channel Diode Spectrometer

    Science.gov (United States)

    Al-Hawat, Sh.; Akel, M.; Wong, C. S.

    2011-12-01

    In this work, the X-ray ratio method using different thicknesses of Al foil absorbers was used to study the influence of copper impurities on the electron temperature determination of the focused plasma in AECS PF-2 with argon filling gas. Five channels of BPX 65 PIN diodes were employed to record the X-ray pulses generated by a low energy Mather type plasma focus device energized by a 25 μF, 15 kV (2.8 kJ) capacitor bank consisting of two capacitors each with 12.5 μF capacity connected in parallel. By comparing the ratio values experimentally obtained for a series of shots at various pressures with theoretically calculated ratios for argon plasma, the X-ray emission ratio was found to correspond to the Cu-Kα line radiation for most of the discharges and only about less than 10% of the measurements give the correct expected electron temperature of 1.5-2.5 keV for the focused argon plasma.

  13. In situ absolute air, O3 and NO densities in the effluent of a cold RF argon atmospheric pressure plasma jet obtained by molecular beam mass spectrometry

    International Nuclear Information System (INIS)

    A molecular beam mass spectrometer has been calibrated and used to measure the air entrainment, nitric oxide and ozone concentrations in the effluent of a cold atmospheric pressure argon RF driven plasma jet. The approaches for calibrating the mass spectrometer for different species are described in detail. Gas phase densities of ozone and nitric oxide up to 7.5 ppm and 4 ppm, respectively, have been measured in the far effluent of the argon plasma jet. The difference in air entrainment when the plasma is undisturbed or is close to a well, which is the case for e.g. in vitro plasma–cell interaction studies, is shown. In addition, an exponential decay of the positive ion flux as a function of distance in the effluent is obtained. Furthermore, the effect of plasma power, duty cycle and air and O2 admixtures introduced into the argon flow on the NO and O3 production is presented, including the possibility of independent control of the NO and O3 flux from the jet. (paper)

  14. Dynamics of plasma expansion and shockwave formation in femtosecond laser-ablated aluminum plumes in argon gas at atmospheric pressures

    Science.gov (United States)

    Miloshevsky, Alexander; Harilal, Sivanandan S.; Miloshevsky, Gennady; Hassanein, Ahmed

    2014-04-01

    Plasma expansion with shockwave formation during laser ablation of materials in a background gasses is a complex process. The spatial and temporal evolution of pressure, temperature, density, and velocity fields is needed for its complete understanding. We have studied the expansion of femtosecond (fs) laser-ablated aluminum (Al) plumes in Argon (Ar) gas at 0.5 and 1 atmosphere (atm). The expansion of the plume is investigated experimentally using shadowgraphy and fast-gated imaging. The computational fluid dynamics (CFD) modeling is also carried out. The position of the shock front measured by shadowgraphy and fast-gated imaging is then compared to that obtained from the CFD modeling. The results from the three methods are found to be in good agreement, especially during the initial stage of plasma expansion. The computed time- and space-resolved fields of gas-dynamic parameters have provided valuable insights into the dynamics of plasma expansion and shockwave formation in fs-pulse ablated Al plumes in Ar gas at 0.5 and 1 atm. These results are compared to our previous data on nanosecond (ns) laser ablation of Al [S. S. Harilal et al., Phys. Plasmas 19, 083504 (2012)]. It is observed that both fs and ns plumes acquire a nearly spherical shape at the end of expansion in Ar gas at 1 atm. However, due to significantly lower pulse energy of the fs laser (5 mJ) compared to pulse energy of the ns laser (100 mJ) used in our studies, the values of pressure, temperature, mass density, and velocity are found to be smaller in the fs laser plume, and their time evolution occurs much faster on the same time scale. The oscillatory shock waves clearly visible in the ns plume are not observed in the internal region of the fs plume. These experimental and computational results provide a quantitative understanding of plasma expansion and shockwave formation in fs-pulse and ns-pulse laser ablated Al plumes in an ambient gas at atmospheric pressures.

  15. Broadband microwave characteristics of a novel coaxial gridded hollow cathode argon plasma.

    Science.gov (United States)

    Gao, Ruilin; Yuan, Chengxun; Li, Hui; Jia, Jieshu; Zhou, Zhong-Xiang; Wang, Ying; Wang, Xiaoou; Wu, Jian

    2016-08-01

    The interaction between microwave and large area plasma is crucially important for space communication. Gas pressure, input power, and plasma volume are critical to both the microwave electromagnetic wave phase shift and electron density. This paper presents a novel type of large coaxial gridded hollow cathode plasma having a 50 cm diameter and a 40 cm thickness. Microwave characteristics are studied using a microwave measurement system that includes two broadband antennae in the range from 2 GHz to 18 GHz. The phase shift under varying gas pressure and input power is shown. In addition, the electron density ne, which varies from 1.2 × 10(16) m(-3) to 8.7 × 10(16) m(-3) under different discharge conditions, is diagnosed by the microwave system. The measured results accord well with those acquired by Langmuir Probe measurement and show that the microwave properties in the large volume hollow cathode discharge significantly depend on the input power and gas pressure. PMID:27587122

  16. Room-temperature atomic layer deposition of ZrO2 using tetrakis(ethylmethylamino)zirconium and plasma-excited humidified argon

    Science.gov (United States)

    Kanomata, K.; Tokoro, K.; Imai, T.; Pansila, P.; Miura, M.; Ahmmad, B.; Kubota, S.; Hirahara, K.; Hirose, F.

    2016-11-01

    Room-temperature atomic layer deposition (ALD) of ZrO2 is developed with tetrakis(ethylmethylamino)zirconium (TEMAZ) and a plasma-excited humidified argon. A growth per cycle of 0.17 nm/cycle at room temperature is confirmed, and the TEMAZ adsorption and its oxidization on ZrO2 are characterized by IR absorption spectroscopy with a multiple internal reflection mode. TEMAZ is saturated on a ZrO2 surface with exposures exceeding ∼2.0 × 105 Langmuir (1 Langmuir = 1.0 × 10-6 Torr s) at room temperature, and the plasma-excited humidified argon is effective in oxidizing the TEMAZ-adsorbed ZrO2 surface. The IR absorption spectroscopy suggests that Zr-OH works as an adsorption site for TEMAZ. The reaction mechanism of room-temperature ZrO2 ALD is discussed in this paper.

  17. Diamondoid synthesis in atmospheric pressure adamantane-argon-methane-hydrogen mixtures using a continuous flow plasma microreactor

    Science.gov (United States)

    Stauss, Sven; Ishii, Chikako; Pai, David Z.; Urabe, Keiichiro; Terashima, Kazuo

    2014-06-01

    Due to their small size, low-power consumption and potential for integration with other devices, microplasmas have been used increasingly for the synthesis of nanomaterials. Here, we have investigated the possibility of using dielectric barrier discharges generated in continuous flow glass microreactors for the synthesis of diamondoids, at temperatures of 300 and 320 K, and applied voltages of 3.2-4.3 kVp-p, at a frequency of 10 kHz. The microplasmas were generated in gas mixtures containing argon, methane, hydrogen and adamantane, which was used as a precursor and seed. The plasmas were monitored by optical emission spectroscopy measurements and the synthesized products were characterized by gas chromatography—mass spectrometry (GC-MS). Depending on the gas composition, the optical emission spectra contained CH and C2 bands of varying intensities. The GC-MS measurements revealed that diamantane can be synthesized by microplasmas generated at atmospheric pressure, and that the yields highly depend on the gas composition and the presence of carbon sources.

  18. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with argon

    International Nuclear Information System (INIS)

    Results are presented from studies of the optical characteristics and parameters of the plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with argon—the working medium of an exciplex gas-discharge emitter. It is established that the partial pressures of mercury dibromide vapor and argon at which the average and pulsed emission intensities in the blue—green spectral region (λmax = 502 nm) reach their maximum values are 0.6 and 114.4 kPa, respectively. The electron energy distribution function, the transport characteristics, the specific power spent on the processes involving electrons, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering from the molecules and atoms of the working mixture are determined by numerical simulation, and their dependences on the reduced electric field strength are analyzed. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules for a reduced electric field of E/N = 20 Td, at which the maximum emission intensity in the blue—green spectral region was observed in this experiment, is found to be 8.1 × 10−15 m3/s

  19. Electron Density and Temperature Measurement by Stark Broadening in a Cold Argon Arc-Plasma Jet at Atmospheric Pressure

    Institute of Scientific and Technical Information of China (English)

    ZHOU Qiuping; CHENG Cheng; MENG Yuedong

    2009-01-01

    Determination of both the electron density and temperature simultaneously in a cold argon arc-plasma jet by analyzing the Stark broadening of two different emission lines is presented.This method is based on the fact that the Stark broadening of different lines has a different dependence on the electron density and temperature.Therefore,a comparison of two or more line broadenings allows us to diagnose the electron density and temperature simultaneously.In this study we used the first two Balmer series hydrogen lines H_α and H_β for their large broadening width.For this purpose,a small amount of hydrogen was introduced into the discharge gas.The results of the Gigosos-Cardenoso computational model,considering more relevant processes for the hydrogen Balmer lines,is used to process the experimental data.With this method,we obtained reliable electron density and temperature,1.88 ×10 ~(15) cm~(-3 )and 13000 K,respectively.Possible sources of error were also analyzed.

  20. Experimental and simulated argon spectra in the 2.3-3.4 nm region from tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Mattioli, M.; Carraro, L.; Puiatti, M.E.; Sattin, F.; Scarin, P.; Valisa, M. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); Consorzio RFX, Corso Stati Uniti 4, Padova (Italy); Fournier, K.B. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); Lawrence Livermore National Laboratory, Livermore, CA (United States); Coffey, I. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); Queen' s University, Belfast (United Kingdom); Giroud, C.; Monier-Garbet, P. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); Association Euratom-CEA sur la Fusion, Centre d' Etudes de Cadarache, St. Paul-lez-Durance (France); Lawson, K. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); UKEA-Euratom Fusion Association, Culham Laboratory Abingdon, Oxfordshire (United Kingdom); O' Mullane, M. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); University of Strathclyde, Glasgow (United Kingdom); Ongena, J. [JET Joint Undertaking, Abingdon, Oxfordshire (United Kingdom); Euratom-Belgian State Association, Ecole Royal Militaire, Brussels (Belgium)

    2001-01-28

    Experimental argon spectra in the 2.3-3.4 nm region from the Jet tokamak on a single null divertor configuration have been simulated. The spectra include lines from five ionization states, namely from Ar{sup 15+} Li-like to Ar{sup 11+} N-like ions. Collisional-radiative models have been constructed for these five Ar ions, considering electron collisional excitation and radiative decay as the populating processes of the excited states. These models give photon emission coefficients for the emitted lines at electron density and temperature values corresponding to the experimental situations. Impurity modelling is performed using a one-dimensional (1D) impurity transport code, calculating the steady-state radial distribution of the Ar ions. The Ar line brightnesses are evaluated in a post-processing subroutine and simulated spectra are obtained. The parts of the spectra corresponding to a single-ionization state do not depend on the experimental conditions and show good agreement except for the amplitude of the simulated 2s-3p Ar XVI line and the shape of the simulated 2.50 nm feature (composed of Ar XVI and Ar XV lines). On the other hand, the superposition of these spectra depends on the experimental conditions, as a consequence of the fact that the ion charge distribution depends not only on the radial profiles of the electron density and temperature, but also of the impurity transport coefficients. Simulations of the Ar spectra (including transport) give confidence in the atomic physics calculations; moreover, they allow the determination of the transport coefficients in the plasma region emitting the considered ionization states, i.e. at the interior of the last closed magnetic surface (LCMS). For a correct simulation of the amplitudes of the spectral features it is necessary to include a transport barrier inside the LCMS. As far as the atomic physics is concerned, we report improved wavelengths for Ar XV transitions and we benchmark photon emission coefficients

  1. Argon/UF6 plasma experiments: UF6 regeneration and product analysis

    Science.gov (United States)

    Roman, W. C.

    1980-03-01

    An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

  2. Argon/UF6 plasma experiments: UF6 regeneration and product analysis

    Science.gov (United States)

    Roman, W. C.

    1980-01-01

    An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

  3. Comparative study on contribution of charge-transfer collision to excitations of iron ion between argon radio-frequency inductively-coupled plasma and nitrogen microwave induced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Kozue; Wagatsuma, Kazuaki, E-mail: wagatuma@imr.tohoku.ac.jp

    2015-06-01

    This paper describes an ionization/excitation phenomenon of singly-ionized iron occurring in an Okamoto-cavity microwave induced plasma (MIP) as well as an argon radio-frequency inductively-coupled plasma (ICP), by comparing the Boltzmann distribution among iron ionic lines (Fe II) having a wide range of the excitation energy from 4.76 to 9.01 eV. It indicated in both the plasmas that plots of Fe II lines having lower excitation energies (4.76 to 5.88 eV) were fitted on each linear relationship, implying that their excitations were caused by a dominant thermal process such as collision with energetic electron. However, Fe II lines having higher excitation energies (more than 7.55 eV) had a different behavior from each other. In the ICP, Boltzmann plots of Fe II lines assigned to the higher excited levels also followed the normal Boltzmann relationship among the low-lying excited levels, even including a deviation from it in particular excited levels having an excitation energy of ca. 7.8 eV. This deviation can be attributed to a charge-transfer collision with argon ion, which results in the overpopulation of these excited levels, but the contribution is small. On the other hand, the distribution of the high-lying excited levels was non-thermal in the Okamoto-cavity MIP, which did not follow the normal Boltzmann relationship among the low-lying excited levels. A probable reason for the non-thermal characteristics in the MIP is that a charge-transfer collision with nitrogen molecule ion having many vibrational/rotational levels could work for populating the 3d{sup 6}4p (3d{sup 5}4s4p) excited levels of iron ion broadly over an energy range of 7.6–9.0 eV, while collisional excitation by energetic electron would occur insufficiently to excite these high-energy levels. - Highlights: • This paper describes the excitation mechanism of iron ion in Okamoto-cavity MIP in comparison with conventional ICP. • Boltzmann distribution is studied among iron ionic lines of

  4. Comparative study on contribution of charge-transfer collision to excitations of iron ion between argon radio-frequency inductively-coupled plasma and nitrogen microwave induced plasma

    International Nuclear Information System (INIS)

    This paper describes an ionization/excitation phenomenon of singly-ionized iron occurring in an Okamoto-cavity microwave induced plasma (MIP) as well as an argon radio-frequency inductively-coupled plasma (ICP), by comparing the Boltzmann distribution among iron ionic lines (Fe II) having a wide range of the excitation energy from 4.76 to 9.01 eV. It indicated in both the plasmas that plots of Fe II lines having lower excitation energies (4.76 to 5.88 eV) were fitted on each linear relationship, implying that their excitations were caused by a dominant thermal process such as collision with energetic electron. However, Fe II lines having higher excitation energies (more than 7.55 eV) had a different behavior from each other. In the ICP, Boltzmann plots of Fe II lines assigned to the higher excited levels also followed the normal Boltzmann relationship among the low-lying excited levels, even including a deviation from it in particular excited levels having an excitation energy of ca. 7.8 eV. This deviation can be attributed to a charge-transfer collision with argon ion, which results in the overpopulation of these excited levels, but the contribution is small. On the other hand, the distribution of the high-lying excited levels was non-thermal in the Okamoto-cavity MIP, which did not follow the normal Boltzmann relationship among the low-lying excited levels. A probable reason for the non-thermal characteristics in the MIP is that a charge-transfer collision with nitrogen molecule ion having many vibrational/rotational levels could work for populating the 3d64p (3d54s4p) excited levels of iron ion broadly over an energy range of 7.6–9.0 eV, while collisional excitation by energetic electron would occur insufficiently to excite these high-energy levels. - Highlights: • This paper describes the excitation mechanism of iron ion in Okamoto-cavity MIP in comparison with conventional ICP. • Boltzmann distribution is studied among iron ionic lines of various

  5. Plasma diagnostics of the SIMPA Ecr ion source by X-ray spectroscopy, Collisions of H-like Neon ions with Argon clusters; Diagnostic du plasma de la source d'ions ECR SIMPA par spectroscopie X, Collision d'ions neon hydrogenoides avec des agregats d'argon

    Energy Technology Data Exchange (ETDEWEB)

    Adrouche, N

    2006-09-15

    The first part of this thesis is devoted to the SIMPA ECR ion source characterization, first, I explored the ion source's capacities on the point of view of extracted currents for three elements, argon, krypton and neon. By analyzing the Bremsstrahlung spectra, I determined the electronic temperature in the plasma and the electronic and ionic densities. In a second time, I recorded high resolution X-spectra of argon and krypton plasma's. By taking into account the principal mechanisms of production of a K hole in the ions inside the plasma, I determined the ionic densities of the high charge states of argon. Lastly, I highlighted a correlation between the ions charge states densities with the intensities of extracted currents. The second part of the thesis is devoted to Ne{sup 9+-} argon clusters collisions. First, I presented simple and effective theoretical models allowing to describe the phenomena occurring during a collision, from the point of view of the projectile. I carried out a simulation for a collision of an ion Ne{sup 9+} with an argon cluster of a given size, which has enabled us to know the energy levels populated during the electronic capture and to follow the number of electrons in each projectile shell. Lastly, I presented the first results of a collision between a Ne{sup 9+} beam and argon clusters. These results, have enabled me by using projectile X-ray spectroscopy during the ions-clusters collision, to evidence a strong clustering of targets atoms and to highlight an electronic multi-capture in the projectile ion excited states. (author)

  6. Etching and structure changes in PMMA coating under argon plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kondyurin, Alexey, E-mail: kond@mailcity.com [Applied and Plasma Physics, School of Physics A28, University of Sydney, New South Wales 2006 (Australia); Bilek, Marcela [Applied and Plasma Physics, School of Physics A28, University of Sydney, New South Wales 2006 (Australia)

    2011-06-15

    A thin (120 nm) polymethylmethacrylate coating was treated by plasma immersion ion implantation with Ar using pulsed bias at 20 kV. Ellipsometry and FTIR spectroscopy and gel-fraction formation were used to detect the structure transformations as a function of ion fluence. The kinetics of etching, variations in refractive index and extinction coefficient in 400-1000 nm of wavelength, concentration changes in carbonyl, ether, methyl and methylene groups all as a function of ion fluence were analyzed. A critical ion fluence of 10{sup 15} ions/cm{sup 2} was observed to be a border between competing depolymerization and carbonization processes. Chemical reactions responsible for reorganization of the PMMA chemical structure under ion beam treatment are proposed.

  7. Argon dilution effects on diamond deposition in electron cyclotron resonance plasma: a double probe study

    International Nuclear Information System (INIS)

    The Ar dilution effects on diamond deposition at moderate pressures (26.6-400 Pa) in an electron cyclotron resonance hydrogen-methane plasma have been studied in connection with electron temperature (Te) and electron density (ne). The double probe measurement revealed the dependence of Te and ne on Ar concentration, pressure, and microwave power. Te decreased in proportion to Ar concentration and was in the range of 3.7-7.5 eV. In contrast, ne exhibited only a small change with increasing Ar concentration except at a higher pressure and was on the order of 1010-1011 cm-3. The Ar dilution promoted nucleation rather than growth, as shown by an increase in nucleation density and renucleation on preexisting diamond grains. The mechanism leading to the peaked growth rate at 33-50 vol.% Ar was explained by the variation of the ion-bombardment energy and the fluxes of radicals, based on the measured Te and ne

  8. Investigation of local thermodynamic equilibrium of laser induced Al2O3-TiC plasma in argon by spatially resolved optical emission spectroscopy

    Science.gov (United States)

    Alnama, K.; Alkhawwam, A.; Jazmati, A. K.

    2016-06-01

    Plasma plume of Al2O3-TiC is generated by third harmonic Q-switched Nd:YAG nanosecond laser. It is characterized using Optical Emission Spectroscopy (OES) at different argon background gas pressures 10, 102, 103, 104 and 105 Pa. Spatial evolution of excitation and ionic temperatures is deduced from spectral data analysis. Temporal evolution of Ti I emission originated from different energy states is probed. The correlation between the temporal behavior and the spatial temperature evolution are investigated under LTE condition for the possibility to use the temporal profile of Ti I emission as an indicator for LTE validity in the plasma.

  9. Investigation of local thermodynamic equilibrium of laser induced Al2O3–TiC plasma in argon by spatially resolved optical emission spectroscopy

    Directory of Open Access Journals (Sweden)

    K. Alnama

    2016-06-01

    Full Text Available Plasma plume of Al2O3–TiC is generated by third harmonic Q-switched Nd:YAG nanosecond laser. It is characterized using Optical Emission Spectroscopy (OES at different argon background gas pressures 10, 102, 103, 104 and 105 Pa. Spatial evolution of excitation and ionic temperatures is deduced from spectral data analysis. Temporal evolution of Ti I emission originated from different energy states is probed. The correlation between the temporal behavior and the spatial temperature evolution are investigated under LTE condition for the possibility to use the temporal profile of Ti I emission as an indicator for LTE validity in the plasma.

  10. Evidence of catalytic production of hot hydrogen in rf generated hydrogen/argon plasmas

    CERN Document Server

    Phillips, J; Akhtar, K; Dhandapani, B; Mills, R; Phillips, Jonathan; Chen, Chun-Ku; Akhtar, Kamran; Dhandapani, Bala; Mills, Randell

    2005-01-01

    In this paper the selective broadening of the atomic hydrogen lines in pure H2 and Ar/H2 mixtures in a large 'GEC' cell (36 cm length_ 14 cm ID) was mapped as a function of position, H2/Ar ratio, time, power, and pressure. Several observations regarding the selective line broadening were particularly notable as they are unanticipated on the basis of earlier models. First, the anomalous broadening of the Balmer lines was found to exist throughout the plasma, and not just in the region between the electrodes. Second, the broadening was consistently a complex function of the operating parameters particularly gas composition (highest in pure H2), position, power, time and pressure. Clearly not anticipated by earlier models were the findings that under some conditions the highest concentration of 'hot' (>10 eV) hydrogen was found at the entry end, and not in the high field region between the electrodes and that in other conditions, the hottest H was at the (exit) pump (also grounded electrode) end. Third, excitati...

  11. Estimation of Minimal Breakdown Point in a GaP Plasma Structure and Discharge Features in Air and Argon Media

    Science.gov (United States)

    Kurt, H. Hilal; Tanrıverdi, Evrim

    2016-08-01

    We present gas discharge phenomena in argon and air media using a gallium phosphide (GaP) semiconductor and metal electrodes. The system has a large-diameter ( D) semiconductor and a microscaled adjustable interelectrode gap ( d). Both theoretical and experimental findings are discussed for a direct-current (dc) electric field ( E) applied to this structure with parallel-plate geometry. As one of the main parameters, the pressure p takes an adjustable value from 0.26 kPa to 101 kPa. After collection of experimental data, a new theoretical formula is developed to estimate the minimal breakdown point of the system as a function of p and d. It is proven that the minimal breakdown point in the semiconductor and metal electrode system differs dramatically from that in metal and metal electrode systems. In addition, the surface charge density σ and spatial electron distribution n e are calculated theoretically. Current-voltage characteristics (CVCs) demonstrate that there exist certain negative differential resistance (NDR) regions for small interelectrode separations (i.e., d = 50 μm) and low and moderate pressures between 3.7 kPa and 13 kPa in Ar medium. From the difference of currents in CVCs, the bifurcation of the discharge current is clarified for an applied voltage U. Since the current differences in NDRs have various values from 1 μA to 7.24 μA for different pressures, the GaP semiconductor plasma structure can be used in microwave diode systems due to its clear NDR region.

  12. Retention of coagulation factors in plasma frozen after extended holding at 1-6 degrees C

    NARCIS (Netherlands)

    Smith, JF; Ness, PM; Moroff, G; Luban, NLC

    2000-01-01

    Background and Objectives: The ability to use plasma, isolated from units of whole blood and frozen within 24 h of phlebotomy, as a substitute for plasma frozen within 8 h of phlebotomy would have several advantages for blood centers. It should provide increased flexibility pertaining to the freezin

  13. Dynamics of the spectral behaviour of an ultrashort laser pulse in an argon-gas-filled capillary discharge-preformed plasma channel

    Directory of Open Access Journals (Sweden)

    Sakai S.

    2013-11-01

    Full Text Available We have reported the argon plasma waveguide produced in an alumina (Al2O3 capillary discharge and used to guide ultrashort laser pulses at intensities of the order of 1016  W/cm2. A one-dimensional magnetohydrodynamic (MHD code was used to evaluate the average degree of ionization of Ar in the preformed plasma channel. The spectrum of the propagated laser pulse in the Ar plasma waveguide was not modified and was well reproduced by a particle-in-cell (PIC simulation under initial ion charge state of Ar3+ in the preformed plasma waveguide. The optimum timing for the laser pulse injection was around 150 ns after initiation of a discharge with a peak current of 200 A.

  14. Dynamics of the spectral behaviour of an ultrashort laser pulse in an argon-gas-filled capillary discharge-preformed plasma channel

    Science.gov (United States)

    Sakai, S.; Higashiguchi, T.; Yugami, N.; Bobrova, N.; Sentoku, Y.; Kodama, R.

    2013-11-01

    We have reported the argon plasma waveguide produced in an alumina (Al2O3) capillary discharge and used to guide ultrashort laser pulses at intensities of the order of 1016 W/cm2. A one-dimensional magnetohydrodynamic (MHD) code was used to evaluate the average degree of ionization of Ar in the preformed plasma channel. The spectrum of the propagated laser pulse in the Ar plasma waveguide was not modified and was well reproduced by a particle-in-cell (PIC) simulation under initial ion charge state of Ar3+ in the preformed plasma waveguide. The optimum timing for the laser pulse injection was around 150 ns after initiation of a discharge with a peak current of 200 A.

  15. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    plasma, in cold activated plasma and in FVII deficient plasma. There was a positive correlation (r=0.96) between FVII:Ag and FVII:Am with slightly but significantly higher values for FVII:Ag (FVII:Ag= 106 U/ml and FVII:Am=100 U/ml; p ... omitting the data from patients on oral anticoagulant therapy, with mean values of 113 U/ml for FVII:Ag and 110 U/ml for FVII:Am (p

  16. Quality Control and Assurance for Coagulation Tests

    Institute of Scientific and Technical Information of China (English)

    彭黎明

    2006-01-01

    @@ The coagulation laboratory aids the clinician in assessing not only the bleeding patient but also the thrombotic patient. The techniques of coagulation laboratory are used to evaluate not only the coagulation system but also the anti-coagulation system, fibrinolytic system,platelet and vascular endothelial function. Enzymes, inhibitors, plasma factors and co-factors, cellular release products, and cell receptors can be measured in coagulation laboratory.

  17. Argon plasma inductively coupled plasma reactive ion etching study for smooth sidewall thin film lithium niobate waveguide application

    Science.gov (United States)

    Ulliac, G.; Calero, V.; Ndao, A.; Baida, F. I.; Bernal, M.-P.

    2016-03-01

    Lithium Niobate (LN) exhibits unique physical properties such as remarkable electro-optical coefficients and it is thus an excellent material for a wide range of fields like optic communications, lasers, nonlinear optical applications, electric field optical sensors etc. In order to further enhance the optical device performance and to be competitive with silicon photonics, sub-micrometric thickness lithium niobate films are crucial. A big step has been achieved with the development of LN thin films by using smart cut technology and wafer bonding and these films are nowadays available in the market. However, it is a challenge to obtain the requirements of the high quality thin LN film waveguide. In this letter, we show smooth ridge waveguides fabricated on 700 nm thickness thin film lithium niobate (TFLN). The fabrication has been done by developing and optimizing three steps of the technological process, the mask fabrication, the plasma etching, and a final cleaning wet etching step in order to remove the lithium niobate redeposition on the side walls. We have obtained single mode propagation with light overall losses of only 5 dB/cm.

  18. Plasma fractionation for blood products: isolation and purification of coagulating factors, albumin and immunoglobulin

    International Nuclear Information System (INIS)

    Approximately 12 million liters of human plasma are fractionated world-wide annually. However, with the market for clotting factors and other haemoderivatives steadily increasing from year to year, the amount processed will also increase correspondingly to keep up with the demand. In Malaysia, part of the need for the blood products are obtained commercially but a major portion of the requirement involves sending the plasma collected by the National Blood Centre to Australia for processing. Following purification and isolation of the blood products, they are sent back to Malaysia for local consumption. As yet there are no plasma fractionation plants in the South East Asia region, it would be advantageous to establish a local fractionation plant as it would be able to cater for local demands of the haemoderivatives and thus reduces the cost of importing these products. Besides, this facility will be able to provide contract fractionation services to the surrounding region. Early work in MINT has started in trying to purify plasma obtained from rats. Purification of the plasma was performed by using Sephadex G-25 column. Short term objective of this project is to develop the technique of extraction, fractionation and purification of blood products such as albumin, globulin and clotting factors (Factor VIII and Factor IX). The long term emphasis will be to scale up the production facility to a pilot plant stage and eventually to a national fractionation and purification plant. (Author)

  19. Mechanisms of suppressing secondary nucleation for low-power and low-temperature microwave plasma self-bias-enhanced growth of diamond films in argon diluted methane

    Directory of Open Access Journals (Sweden)

    Ji-heng Jiang

    2011-12-01

    Full Text Available We report on mechanisms for suppressing diamond secondary nucleation in microwave plasma self-bias-enhanced growth (SBEG of diamond films in methane diluted by argon. High-density plasma at a small distance from the substrate induces a floating potential which promotes high-flux, low-energy ion bombardment on diamond growing surfaces along with an equal flux of electrons. Increased atomic hydrogen generated by electron impact dissociation of methane and low-energy ion bombardment help remove hydrocarbon coatings on diamond grains in favor of continuous grain growth and, therefore, the suppression of secondary diamond nucleation. Energetic meta-stable excited argon, abundant C2 dimers, and enhanced effective surface temperature due to low-energy ion bombardment further promote the diamond grain growth resulting in the deposition of a diamond film with columnar diamond grains of much larger grain sizes and a much lower density of grain boundaries than ultrananocrystalline diamond (UNCD films grown under similar conditions without optimized plasma-substrate interactions. SEM, XRD, PL, and Raman scattering help confirm the deposition of diamond films with columnar grains.

  20. Ambient air particle transport into the effluent of a cold atmospheric-pressure argon plasma jet investigated by molecular beam mass spectrometry

    International Nuclear Information System (INIS)

    Ambient air species, which are transported into the active effluent of an atmospheric-pressure plasma jet result in highly reactive oxygen and nitrogen species (RONS). Especially for the envisaged application field of plasma medicine, these RONS are responsible for strong biological responses. In this work, the effect of ambient air transport into the effluent of an atmospheric-pressure plasma argon jet on the on-axis densities of nitrogen, oxygen and argon was investigated by means of absolutely calibrated molecular beam mass spectrometry (MBMS). According to biomedical experiments a (bottomless) Petri dish was installed in front of the MBMS. In the following, the near flow field is referring to the region close to the nozzle exit and the far flow field is referring to the region beyond that. The absolute on-axis densities were obtained by three different methods, for the near flow field with VUV-absorption technique, for the far flow field with the MBMS and the total flow field was calculated with a computational fluid dynamics (CFD) simulation. The results of the ambient air particle densities of all independent methods were compared and showed an excellent agreement. Therefore the transport processes of ambient air species can be measured for the whole effluent of an atmospheric-pressure plasma jet. Additionally, with the validation of the simulation it is possible in future to calculate the ambient species transport for various gas fluxes in the same turbulent flow regime. Comparing the on-axis densities obtained with an ignited and with a non-ignited plasma jet shows that for the investigated parameters, the main influence on the ambient air species transport is due to the increased temperature in the case when the jet is switched on. Moreover, the presence of positive ions (e.g. ArN2+) formed due to the interaction of plasma-produced particles and ambient air species, which are transported into the effluent, is shown. (paper)

  1. COAGULATION ACTIVITY IN LIVER DISEASE

    Directory of Open Access Journals (Sweden)

    Dr. Sheikh Sajjadieh Mohammad Reza

    2009-07-01

    Full Text Available Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation markers were assayed in 60 participants: 20 patients with chronic hepatitis, 20 patients with cirrhosis, and 20 healthy individuals (control. Plasma levels of anti-thrombin III were determined by a chromogenic substrate method, and plasma concentrations of fibrinogen were analyzed by the Rutberg method. Commercially available assays were used for laboratory coagulation tests. The levels of coagualation activity markers in patients with chronic liver disease were significantly different in comparison to those in healthy participants. These results indicate the utility of measuring markers for coagulation activity in determining which cirrhosis patients are more susceptible to disseminated intravascular coagulation.

  2. Effects of Rutin and Hesperidin and Their Al(III and Cu(II Complexes on in Vitro Plasma Coagulation Assays

    Directory of Open Access Journals (Sweden)

    Vesna Kuntić

    2011-02-01

    Full Text Available Two flavonoids, rutin and hesperidin, were investigated in vitro for anticoagulant activity through coagulation tests: activated partial thromboplastin time (aPTT, prothrombin time (PT and thrombin time (TT. Only an ethanolic solution of rutin at the concentration of 830 µM prolonged aPTT, while TT and PT were unaffected. In order to evaluate whether the prolongation of aPTT was due to the decrease of coagulation factors, the experiment with deficient plasma was performed, showing the effects on factors VIII and IX. Since pharmacological activity of flavonoids is believed to increase when they are coordinated with metal ions, complexes of these flavonoids with Al(III and Cu(II ions were also tested. The results showed that complexes significantly prolonged aPTT and had no effects on PT and TT. Assay with deficient plasma (plasma having the investigated factor at less then 1% revealed that complexes could bind to the coagulation factors, what may lead to a non-specific inhibition and aPTT prolongation. An effort was made to correlate stability of complexes with their anticoagulant properties.

  3. Study on the effect of hydrogen addition on the variation of plasma parameters of argon-oxygen magnetron glow discharge for synthesis of TiO2 films

    Directory of Open Access Journals (Sweden)

    Partha Saikia

    2016-04-01

    Full Text Available We report the effect of hydrogen addition on plasma parameters of argon-oxygen magnetron glow discharge plasma in the synthesis of H-doped TiO2 films. The parameters of the hydrogen-added Ar/O2 plasma influence the properties and the structural phases of the deposited TiO2 film. Therefore, the variation of plasma parameters such as electron temperature (Te, electron density (ne, ion density (ni, degree of ionization of Ar and degree of dissociation of H2 as a function of hydrogen content in the discharge is studied. Langmuir probe and Optical emission spectroscopy are used to characterize the plasma. On the basis of the different reactions in the gas phase of the magnetron discharge, the variation of plasma parameters and sputtering rate are explained. It is observed that the electron and heavy ion density decline with gradual addition of hydrogen in the discharge. Hydrogen addition significantly changes the degree of ionization of Ar which influences the structural phases of the TiO2 film.

  4. Gas barrier properties of hydrogenated amorphous carbon films coated on polyethylene terephthalate by plasma polymerization in argon/n-hexane gas mixture

    Energy Technology Data Exchange (ETDEWEB)

    Polonskyi, Oleksandr; Kylián, Ondřej, E-mail: ondrej.kylian@gmail.com; Petr, Martin; Choukourov, Andrei; Hanuš, Jan; Biederman, Hynek

    2013-07-01

    Hydrogenated amorphous carbon thin films were deposited by RF plasma polymerization in argon/n-hexane gas mixture on polyethylene terephthalate (PET) foils. It was found that such deposited films may significantly improve the barrier properties of PET. It was demonstrated that the principal parameter that influences barrier properties of such deposited films towards oxygen and water vapor is the density of the coatings. Moreover, it was shown that for achieving good barrier properties it is advantageous to deposit coatings with very low thickness. According to the presented results, optimal thickness of the coating should not be higher than several tens of nm. - Highlights: • a-C:H films were prepared by plasma polymerization in Ar/n-hexane atmosphere. • Barrier properties of coatings are dependent on their density and thickness. • Highest barrier properties were observed for films with thickness 15 nm.

  5. Gas barrier properties of hydrogenated amorphous carbon films coated on polyethylene terephthalate by plasma polymerization in argon/n-hexane gas mixture

    International Nuclear Information System (INIS)

    Hydrogenated amorphous carbon thin films were deposited by RF plasma polymerization in argon/n-hexane gas mixture on polyethylene terephthalate (PET) foils. It was found that such deposited films may significantly improve the barrier properties of PET. It was demonstrated that the principal parameter that influences barrier properties of such deposited films towards oxygen and water vapor is the density of the coatings. Moreover, it was shown that for achieving good barrier properties it is advantageous to deposit coatings with very low thickness. According to the presented results, optimal thickness of the coating should not be higher than several tens of nm. - Highlights: • a-C:H films were prepared by plasma polymerization in Ar/n-hexane atmosphere. • Barrier properties of coatings are dependent on their density and thickness. • Highest barrier properties were observed for films with thickness 15 nm

  6. Deviation from Boltzmann distribution in excited energy levels of singly-ionized iron in an argon glow discharge plasma for atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lei; Kashiwakura, Shunsuke; Wagatsuma, Kazuaki, E-mail: wagatuma@imr.tohoku.ac.jp

    2012-01-15

    A Boltzmann plot for many iron ionic lines having excitation energies of 4.7-9.1 eV was investigated in an argon glow discharge plasma when the discharge parameters, such as the voltage/current and the gas pressure, were varied. A Grimm-style radiation source was employed in a DC voltage range of 400-800 V at argon pressures of 400-930 Pa. The plot did not follow a linear relationship over a wide range of the excitation energy, but it yielded a normal Boltzmann distribution in the range of 4.7-5.8 eV and a large overpopulation in higher-lying excitation levels of iron ion. A probable reason for this phenomenon is that excitations for higher excited energy levels of iron ion would be predominantly caused by non-thermal collisions with argon species, the internal energy of which is received by iron atoms for the ionization. Particular intense ionic lines, which gave a maximum peak of the Boltzmann plot, were observed at an excitation energy of ca. 7.7 eV. They were the Fe II 257.297-nm and the Fe II 258.111-nm lines, derived from the 3d{sup 5}4s4p {sup 6}P excited levels. The 3d{sup 5}4s4p {sup 6}P excited levels can be highly populated through a resonance charge transfer from the ground state of argon ion, because of good matching in the excitation energy as well as the conservation of the total spin before and after the collision. An enhancement factor of the emission intensity for various Fe II lines could be obtained from a deviation from the normal Boltzmann plot, which comprised the emission lines of 4.7-5.8 eV. It would roughly correspond to a contribution of the charge transfer excitation to the excited levels of iron ion, suggesting that the charge-transfer collision could elevate the number density of the corresponding excited levels by a factor of ca.10{sup 4}. The Boltzmann plots give important information on the reason why a variety of iron ionic lines can be emitted from glow discharge plasmas.

  7. Deviation from Boltzmann distribution in excited energy levels of singly-ionized iron in an argon glow discharge plasma for atomic emission spectrometry

    International Nuclear Information System (INIS)

    A Boltzmann plot for many iron ionic lines having excitation energies of 4.7–9.1 eV was investigated in an argon glow discharge plasma when the discharge parameters, such as the voltage/current and the gas pressure, were varied. A Grimm-style radiation source was employed in a DC voltage range of 400–800 V at argon pressures of 400–930 Pa. The plot did not follow a linear relationship over a wide range of the excitation energy, but it yielded a normal Boltzmann distribution in the range of 4.7–5.8 eV and a large overpopulation in higher-lying excitation levels of iron ion. A probable reason for this phenomenon is that excitations for higher excited energy levels of iron ion would be predominantly caused by non-thermal collisions with argon species, the internal energy of which is received by iron atoms for the ionization. Particular intense ionic lines, which gave a maximum peak of the Boltzmann plot, were observed at an excitation energy of ca. 7.7 eV. They were the Fe II 257.297-nm and the Fe II 258.111-nm lines, derived from the 3d54s4p 6P excited levels. The 3d54s4p 6P excited levels can be highly populated through a resonance charge transfer from the ground state of argon ion, because of good matching in the excitation energy as well as the conservation of the total spin before and after the collision. An enhancement factor of the emission intensity for various Fe II lines could be obtained from a deviation from the normal Boltzmann plot, which comprised the emission lines of 4.7–5.8 eV. It would roughly correspond to a contribution of the charge transfer excitation to the excited levels of iron ion, suggesting that the charge-transfer collision could elevate the number density of the corresponding excited levels by a factor of ca.104. The Boltzmann plots give important information on the reason why a variety of iron ionic lines can be emitted from glow discharge plasmas.

  8. Ontogenetic variation of metalloproteinases and plasma coagulant activity in venoms of wild Bothrops atrox specimens from Amazonian rain forest.

    Science.gov (United States)

    López-Lozano, Jorge Luis; de Sousa, Marcelo Valle; Ricart, Carlos André O; Chávez-Olortegui, Carlos; Flores Sanchez, Eladio; Muniz, Emiro G; Bührnheim, Paulo F; Morhy, Lauro

    2002-07-01

    A comparative study of venoms from juvenile, sub-adult and adult wild Bothrops atrox specimens captured in Manaus region (Brazil) was performed. All venoms tested had acidic pH (5.5) and the human plasma coagulant activity was higher in venoms from juvenile and sub-adult specimens than in adults. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) showed that the most intense bands in adult venoms corresponded to polypeptides of 23 and 50kDa. The 23kDa protein was not detected in juvenile venoms. The 23 and 50kDa proteins were purified by two steps of reversed phase-HPLC followed by size exclusion HPLC. Partial amino acid sequence of the 23kDa protein showed homology to metalloproteinases from other snake venoms. Electrospray ionization mass spectrometric analysis (ESI-MS) showed that the 23kDa band contained at least three isoforms of 23030, 23300 and 23645Da. The 50kDa polypeptide was N-terminally blocked for Edman degradation and presented molecular masses ranging from 46.8 to 49.4kDa by ESI-MS. Both proteins were detected by anti-mutalysin II antibodies in immunoblotting assay indicating that they belong to the metalloproteinase family. Immunoblotting analysis also showed that the 23kDa band increased in intensity from juvenile to adult specimens.SDS-PAGE analysis of juvenile and adult venoms following autoproteolysis in pH 7.4 suggested that endogenous venom metalloproteinases can digest the 50kDa metalloproteinase, originating a new protein band of 27kDa. It was also demonstrated in juvenile venoms that the 23kDa band was not the result of proteolytic processing of the 50kDa metalloproteinase. PMID:12076654

  9. Spatial distribution of the temperature and the number densities of electrons and atomic and ionic species in an inductively coupled RF argon plasma, ch. 3

    International Nuclear Information System (INIS)

    A survey of the literature shows that the values found for the excitation parameters (temperature and electron number density) in an inductively coupled radio-frequency argon plasma at atmospheric pressure (ICP) depend on the plasma configuration and the measuring procedure. The present study proposes a novel method for measuring excitation temperatures that does not require a knowledge of transition probabilities. The experimental work concerns measurements of the spatial distributions of the temperature, the number densities of the electrons and various atomic and ionic species in a low-power (approximately o.5kW) ICP for analytical purposes operated at either of two extreme carrier gas flow rates. Observations were made at three different heights above the induction coil. At high flow rate (approximately 51/min) the familiar hollow configuration of the plasma is demonstrated by off-axis maxima for the temperature and the number densities of electrons and atomic species at all observation heights. At low flow rate (approximately 1 l./min), the radial atom number density distributions are parabolically shaped and constricted to a smaller channel at all observation heights. The authors conclude from the results that both the plasma configurations are not in a state of complete local thermal equilibrium at observation heights used for analytical work (i.e., above the coil)

  10. Enhancement of intensities in glow discharge mass spectrometry by using mixtures of argon and helium as plasma gases.

    Science.gov (United States)

    Lange, Britta; Matschat, Ralf; Kipphardt, Heinrich

    2007-12-01

    Glow discharge mass spectrometry (GD-MS) is an excellent technique for fast multi-element analysis of pure metals. In addition to metallic impurities, non-metals also can be determined. However, the sensitivity for these elements can be limited due to their high first ionization potentials. Elements with a first ionization potential close to or higher than that of argon, which is commonly used as discharge gas in GD-MS analysis, are ionized with small efficiency only. To improve the sensitivity of GD-MS for such elements, the influence of different glow-discharge parameters on the peak intensity of carbon, chlorine, fluorine, nitrogen, phosphorus, oxygen, and sulfur in pure copper samples was investigated with an Element GD (Thermo Fisher Scientific) GD-MS. Discharge current, discharge gas flow, and discharge gas composition, the last of which turned out to have the greatest effect on the measured intensities, were varied. Argon-helium mixtures were used because of the very high potential of He to ionize other elements, especially in terms of the high energy level of its metastable states. The effect of different Ar-He compositions on the peak intensity of various impurities in pure copper was studied. With Ar-He mixtures, excellent signal enhancements were achieved in comparison with use of pure Ar as discharge gas. In this way, traceable linear calibration curves for phosphorus and sulfur down to the microg kg(-1) range could be established with high sensitivity and very good linearity using pressed powder samples for calibration. This was not possible when pure argon alone was used as discharge gas. PMID:17940753

  11. On local thermal equilibrium and potential gradient vs current characteristic in wall-stabilized argon plasma arc at 0.1 atm pressure

    International Nuclear Information System (INIS)

    In wall-stabilized arc which is a very useful means for determining the transport characteristics of high temperature gases, it is the premise that the inside of arc column is in complete local thermal equilibrium (LTE). In general, the higher the gas pressure, the easier the establishment of LTE, accordingly the experimental investigations on the characteristics of arc discharge as well as the transport characteristics so far were limited to the region of relatively high pressure. However, the authors have found that the theoretical potential vs. current characteristic obtained by the transport characteristic was greatly different from the actually measured one in low pressure region, as the fundamental characteristic of wall-stabilized argon plasma arc below atmospheric pressure. This time, they have clarified this discrepancy at 0.1 atm using the plasma parameters obtained through the spectroscopic measurements. The spectroscopic measurements have been performed through the side observation window at the position 5.5 cm away from the cathode, when arc was ignited vertically at the electrodes distant by 11 cm. Arc radius was 0.5 cm. Electron density and temperature, gas temperature and the excitation density of argon neutral atoms have been experimentally measured. The investigations showed that, in the region of low arc current, where the ratio of current to arc radius is less than 200 A/cm, the fall of gas temperature affected greatly on the decrease of axial electric field of arc column. The non-equilibrium between electron temperature and gas temperature decreased with the increase of arc current, and it was concluded that LTE has been formed at the center portion of arc column above I/R = 300 A/cm. (Wakatsuki, Y.)

  12. Charge-state and element-resolved ion energies in the cathodic arc plasma from composite AlCr cathodes in argon, nitrogen and oxygen atmospheres

    CERN Document Server

    Franz, Robert; Anders, André

    2014-01-01

    The energy distribution functions of ions in the cathodic arc plasma using composite AlCr cathodes were measured as a function of the background gas pressure in the range 0.5 to 3.5 Pa for different cathode compositions and gas atmospheres. The most abundant aluminium ions were Al$^{+}$ regardless of the background gas species, whereas Cr$^{2+}$ ions were dominating in Ar and N$_2$ and Cr$^{+}$ in O$_2$ atmospheres. The energy distributions of the aluminium and chromium ions typically consisted of a high energy fraction due to acceleration in the expanding plasma plume from the cathode spot and thermalised ions that were subjected to collisions in the plasma cloud. The fraction of the latter increased with increasing background gas pressure. Atomic nitrogen and oxygen ions showed similar energy distributions as the aluminium and chromium ions, whereas the argon and molecular nitrogen and oxygen ions were mainly thermalised. In addition to the positively charged metal and gas ions, negatively charged oxygen an...

  13. A new flexible DBD device for treating infected wounds: in vitro and ex vivo evaluation and comparison with a RF argon plasma jet

    International Nuclear Information System (INIS)

    Cold plasma has been shown to provide a promising alternative antimicrobial treatment for wound healing. We developed and tested a flexible surface dielectric barrier discharge (DBD) and compared it to an argon gas based plasma jet operated remotely with a distance between plasma plume and sample of 8 mm. Tests were conducted using different models: on cultured cells, on ex vivo human skin and on bacteria (Pseudomonas aeruginosa) (on agar, in suspension, in collagen/elastin matrix or on ex vivo human skin), allowing us to directly compare bactericidal with safety aspects under identical conditions. Both plasma devices were highly efficient when used on bacteria in non-buffered solutions, but DBD was faster in reaching the maximum bacterial reduction. Treatment of bacteria on intact skin with DBD resulted in up to 6 log reductions in 3 min. The jet was far less efficient on intact skin. Even after 8 min treatment no more than 2 log reductions were obtained with the jet. Treatment of bacteria in burn wound models with DBD for 6 min resulted in a 4.5 log reduction. Even when using DBD for 6 min on infected burn wound models with colonizing or biofilm phase bacteria, the log reductions were 3.8 or 3.2 respectively. DBD plasma treatment for 6 min did not affect fibroblast viability, whereas a treatment for 8 min was detrimental. Similarly, treatment with DBD or plasma jet for 6 min did also not affect the metabolic activity of skin biopsies. After treatment for 8 min with DBD or plasma jet, 78% or 60% of activity in skin biopsies remained, respectively. Multiple treatments of in vitro burn wound models with surface DBD for 6 min or with plasma jet for 8 min did not affect re-epithelialization. With the flexible surface DBD plasma strip we were able to quickly inactivate large numbers of bacteria on and in skin. Under the same conditions, viability of skin cells or re-epithelialization was not affected. The DBD source has potential for treating

  14. A new flexible DBD device for treating infected wounds: in vitro and ex vivo evaluation and comparison with a RF argon plasma jet

    Science.gov (United States)

    Boekema, B. K. H. L.; Vlig, M.; Guijt, D.; Hijnen, K.; Hofmann, S.; Smits, P.; Sobota, A.; van Veldhuizen, E. M.; Bruggeman, P.; Middelkoop, E.

    2016-02-01

    Cold plasma has been shown to provide a promising alternative antimicrobial treatment for wound healing. We developed and tested a flexible surface dielectric barrier discharge (DBD) and compared it to an argon gas based plasma jet operated remotely with a distance between plasma plume and sample of 8 mm. Tests were conducted using different models: on cultured cells, on ex vivo human skin and on bacteria (Pseudomonas aeruginosa) (on agar, in suspension, in collagen/elastin matrix or on ex vivo human skin), allowing us to directly compare bactericidal with safety aspects under identical conditions. Both plasma devices were highly efficient when used on bacteria in non-buffered solutions, but DBD was faster in reaching the maximum bacterial reduction. Treatment of bacteria on intact skin with DBD resulted in up to 6 log reductions in 3 min. The jet was far less efficient on intact skin. Even after 8 min treatment no more than 2 log reductions were obtained with the jet. Treatment of bacteria in burn wound models with DBD for 6 min resulted in a 4.5 log reduction. Even when using DBD for 6 min on infected burn wound models with colonizing or biofilm phase bacteria, the log reductions were 3.8 or 3.2 respectively. DBD plasma treatment for 6 min did not affect fibroblast viability, whereas a treatment for 8 min was detrimental. Similarly, treatment with DBD or plasma jet for 6 min did also not affect the metabolic activity of skin biopsies. After treatment for 8 min with DBD or plasma jet, 78% or 60% of activity in skin biopsies remained, respectively. Multiple treatments of in vitro burn wound models with surface DBD for 6 min or with plasma jet for 8 min did not affect re-epithelialization. With the flexible surface DBD plasma strip we were able to quickly inactivate large numbers of bacteria on and in skin. Under the same conditions, viability of skin cells or re-epithelialization was not affected. The DBD source has potential for treating

  15. Spectroscopy of reactive species produced by low-energy atmospheric-pressure plasma on conductive target material surface

    Science.gov (United States)

    Yamada, Hiromasa; Sakakita, Hajime; Kato, Susumu; Kim, Jaeho; Kiyama, Satoru; Fujiwara, Masanori; Itagaki, Hirotomo; Okazaki, Toshiya; Ikehara, Sanae; Nakanishi, Hayao; Shimizu, Nobuyuki; Ikehara, Yuzuru

    2016-10-01

    A method for blood coagulation using low-energy atmospheric-pressure plasma (LEAPP) is confirmed as an alternative procedure to reduce tissue damage caused by heat. Blood coagulation using LEAPP behaves differently depending on working gas species; helium is more effective than argon in promoting fast coagulation. To analyse the difference in reactive species produced by helium and argon plasma, spectroscopic measurements were conducted without and with a target material. To compare emissions, blood coagulation experiments using LEAPP for both plasmas were performed under almost identical conditions. Although many kinds of reactive species such as hydroxyl radicals and excited nitrogen molecules were observed with similar intensity in both plasmas, intensities of nitrogen ion molecules and nitric oxide molecules were extremely strong in the helium plasma. It is considered that nitrogen ion molecules were mainly produced by penning ionization by helium metastable. Near the target, a significant increase in the emissions of reactive species is observed. There is a possibility that electron acceleration was induced in a local electric field formed on the surface. However, in argon plasma, emissions from nitrogen ion were not measured even near the target surface. These differences between the two plasmas may be producing the difference in blood coagulation behaviour. To control the surrounding gas of the plasma, a gas-component-controllable chamber was assembled. Filling the chamber with O2/He or N2/He gas mixtures selectively produces either reactive oxygen species or reactive nitrogen species. Through selective treatments, this chamber would be useful in studying the effects of specific reactive species on blood coagulation.

  16. Study on Blood Coagulant/Fibrinolytic Activity at Plasma andMonocytic Levels in Coronary Heart Disease Patients withBlood-Stasis Syndrome of Traditional Chinese Medicine

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective: To explore and compare the changes of coagulant/fibrinolytic activity in coronary heart disease (CHD) patients with Blood Stasis Syndrome of TCM and evaluate the roles of these changes. Methods: Eighty patients of CHD were divided into two groups by Syndrome Differentiation of TCM, the Blood-Stasis (BS) group (30 cases) and the non-Blood-Stasis (NBS) group (50 cases, including 27 cases of Phlegm-Dampness Syndrome and 23 cases of Qi-Stagnation Syndrome); and 20 healthy persons were enrolled as normal control group. Tissue type plasminogen activator (t-PA) and its inhibitor (PAI-1) in plasma and in human peripheral blood monocyte cell (PBMC), as well as the procoagulant activity (PCA) in PBMC were measured by chromogenic substrate method. Results: The plasma PAI-1 activity and PCA of PBMC in the BS group were significantly higher than those in the NBS group and the normal control group (P<0.01). PAI-1 activity of PBMC in the two groups of CHD patients was higher than those in the normal control group significantly (P<0.01), but no significant difference was found between the BS group and the NBS group (P>0.05). The difference of plasma t-PA activity between the two groups of CHD was insignificant. The PBMC t-PA activity in the BS group was lower than that in the NBS and normal control groups (P<0.01). Conclusion: In the CHD patients with BS, the PBMC PCA was increased and the fibrinolytic activity at both plasma and monocyte levels lowered significantly, these changes in coagulant/fibrinolytic activity may be the important pathologic factors in forming BS which suggests that CHD patients with BS were in the prothrombotic state.

  17. Electrical and spectral characteristics of an atmospheric pressure argon plasma jet generated with tube-ring electrodes in surface dielectric barrier discharge

    International Nuclear Information System (INIS)

    An atmospheric-pressure argon plasma jet is generated with tube-ring electrodes in surface dielectric barrier discharge by a sinusoidal excitation voltage at 8 kHz. The electrical and spectral characteristics are estimated such as conduction and displacement current, electric-field, electron temperature, rotational temperature of N2 and OH, electronic excitation temperature, and oxygen atomic density. It is found that the electric-field magnitudes in the top area of the ground electrode are higher than that in the bottom area of the power electrode, and the electron temperature along radial direction is in the range of 9.6–10.4 eV and along axial direction in the range of 4.9–10 eV. The rotational temperature of N2 obtained by comparing the simulated spectrum with the measured spectrum at the C3Πu → B3Πg(Δv = − 2) band transition is in the range of 342–387 K, the electronic excitation temperature determined by Boltzmann's plot method is in the range of 3188–3295 K, and the oxygen atomic density estimated by the spectral intensity ratio of atomic oxygen line λ = 844.6 nm to argon line λ = 750.4 nm is in the order of magnitude of 1016 cm−3, respectively. - Highlights: ► The conduction and displacement current are calculated by equivalent circuit diagram. ► The 2D distribution of electric-field magnitude is calculated by ElecNet software. ► The electron temperature along axial direction is in the range of 4.9–10 eV. ► The oxygen atomic density is about a magnitude of 1016 cm−3

  18. Modification and optimization of a 50 MHz inductively coupled argon plasma with special reference to analyses using organic solvents

    Science.gov (United States)

    Boumans, P. W. J. M.; Lux-Steiner, M. Ch.

    The torch and nebulizer of an existing argon ICP system were modified and the system was (re-) optimized for aqueous and organic liquids. The paper describes the design considerations and construction of (1) a new, streamlined torch including a torch base used in this study, where a demountable rather than a prealigned version of the torch was preferred; (2) a cross-flow pneumatic nebulizer with adjustable teflon capillaries including a spray chamber with flow spoiler, concentric aerosol pick-up tube, and "U" tube with unequal legs to smooth the flow of wasted liquid to the drain. The (re)-optimization of the ICP system for analysis of aqueous solutions with inorganic matter or with both inorganic and organic matter is discussed in the light of earlier work in this laboratory regarding the selection of "compromise conditions" and the choice of representative spectral lines and measurement criteria for establishing such compromise conditions. In this context the authors consider the concepts of norm temperature and "hard" and "soft" lines, as well as recent results of measurements of spatial distributions in ICPs. The authors further describe experiments aimed at the optimization of the operating conditions of an "organic ICP" using methyl isobutyl ketone (MIBK) as organic solvent. Trends of net line and background signals and signal-to-background ratios with the ICP parameters (power; outer, intermediate and carrier gas flow; observation height; liquid feed rate) are reported, and a rational choice of compromise conditions for the ICP is argued. Performance characteristics of the modified ICP system, such as detection limits, precision and interference level, achieved under compromise conditions, have been communicated in a previous report [ Spectrochim. Acta36B, 1031 (1981)] to demonstrate the capabilities of the system for analysis of aqueous solutions. Detection limits in MIBK and oil diluted in MIBK are reported in the present work as an illustration of the

  19. UPLC-MRM Mass Spectrometry Method for Measurement of the Coagulation Inhibitors Dabigatran and Rivaroxaban in Human Plasma and Its Comparison with Functional Assays.

    Directory of Open Access Journals (Sweden)

    Joachim Kuhn

    Full Text Available The fast, precise, and accurate measurement of the new generation of oral anticoagulants such as dabigatran and rivaroxaban in patients' plasma my provide important information in different clinical circumstances such as in the case of suspicion of overdose, when patients switch from existing oral anticoagulant, in patients with hepatic or renal impairment, by concomitant use of interaction drugs, or to assess anticoagulant concentration in patients' blood before major surgery.Here, we describe a quick and precise method to measure the coagulation inhibitors dabigatran and rivaroxaban using ultra-performance liquid chromatography electrospray ionization-tandem mass spectrometry in multiple reactions monitoring (MRM mode (UPLC-MRM MS. Internal standards (ISs were added to the sample and after protein precipitation; the sample was separated on a reverse phase column. After ionization of the analytes the ions were detected using electrospray ionization-tandem mass spectrometry. Run time was 2.5 minutes per injection. Ion suppression was characterized by means of post-column infusion.The calibration curves of dabigatran and rivaroxaban were linear over the working range between 0.8 and 800 μg/L (r >0.99. Limits of detection (LOD in the plasma matrix were 0.21 μg/L for dabigatran and 0.34 μg/L for rivaroxaban, and lower limits of quantification (LLOQ in the plasma matrix were 0.46 μg/L for dabigatran and 0.54 μg/L for rivaroxaban. The intraassay coefficients of variation (CVs for dabigatran and rivaroxaban were < 4% and 6%; respectively, the interassay CVs were < 6% for dabigatran and < 9% for rivaroxaban. Inaccuracy was < 5% for both substances. The mean recovery was 104.5% (range 83.8-113.0% for dabigatran and 87.0% (range 73.6-105.4% for rivaroxaban. No significant ion suppressions were detected at the elution times of dabigatran or rivaroxaban. Both coagulation inhibitors were stable in citrate plasma at -20°C, 4°C and even at RT for at

  20. Argon ion beam interaction on polyethylene terephthalate surface by a 4 kJ plasma focus device

    Indian Academy of Sciences (India)

    Habibi Morteza; Alavi M H S

    2016-03-01

    Polyethylene terephthalate (PET) has a wide variety of applications ranging from making regular bottles to biosensors. However, for many of these applications, surface treatment is needed to improve its surface characteristics such as adhesion to other materials. In this study, we focussed on treating PET foils by dense Ar pulsed plasma produced by a 4.5 kJ Mather-type plasmafocus device (20 kV, 40 $\\mu$f, 115 nH) to examine its ability to make the PET surface hydrophilic. The most common method to examine this characteristic is measuring the water contact angle on a polymer surface. The results show that while the energy and density of plasma in our device are higher compared to other devices, as the exposure time is very low, the device can enhance thewettability of PET film surfaces.

  1. Permeation barrier performance of Hot Wire-CVD grown silicon-nitride films treated by argon plasma

    OpenAIRE

    Majee, S.; Cerqueira, M. F.; Tondelier, D.; Vanel, J. C.; Geffroy, B.; Bonnassieux, Y.; Alpuim, P.; Bourée, J. E.

    2015-01-01

    In this work SiNx thin films have been deposited by Hot-Wire Chemical Vapor Deposition (HW-CVD) technique to be used as encapsulation barriers for flexible organic electronic devices fabricated on polyethylene terephthalate (PET) substrates. First results of SiNx multilayers stacked and stacks of SiNx single-layers (50 nm each) separated by an Ar-plasma surface treatment are reported. The encapsulation barrier properties of these different multilayers are assessed using the electrical calcium...

  2. Irradiation influence on Mylar and Makrofol induced by argon ions in a plasma immersion ion implantation system

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, A. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Aal, S.A. Abd El [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Ghazaly, M. El [Physiology Department, College of Medicine, Taif University, P.O. 888, Taif (Saudi Arabia); Physics Department, Faculty of Science, Zagazig University, P.O. 44519, Zagazig (Egypt)

    2015-08-30

    Highlights: • A home-built plasma immersion ion implantation system was tested in modifying surfaces. • Wettability modifications within the energy range 10 keV implantation are not investigated elsewhere, up to our knowledge. • The wettability of Mylar and Makrofol surface was enhanced by the dual effect of ion implantation and plasma treatment. • The improved wettability was found to depend on both surface roughness and chemistry. • The adhesive bonding and surface energy of the polymers are improved. - Abstract: Mylar and Makrofol polycarbonate polymers were irradiated by Ar ions in a plasma immersion ion implantation (PIII) system. The surface wettability of both polymers was investigated by employing the contact angle method. The measured contact angles were found to depend on the surface layer properties. Good wetting surfaces were found to depend not only on surface roughness but also on its chemistry that analyzed by Fourier transform infrared (FTIR) spectroscopy. Surfaces topography and roughness was investigated and correlated to their surface energy which studied with the aid of acid-base model for evaluating the improvement of surface wettability after irradiation. PIII improves polymers surface properties efficiently in a controllable way.

  3. Spectroscopic characterization of low power argon microwave-induced plasma with gaseous species produced from ethanol-water solutions in continuous hydride generation process

    International Nuclear Information System (INIS)

    Low power microwave-induced argon plasma generated by resonant TE101 rectangular cavity was investigated upon introduction of volatile species formed in the reaction with sodium tetraborohydrate(III) in hydrochloric acid-ethanol solution. The molecular emission bands of OH and CH were used for rotational temperature (Trot) determination, while the atomic emission lines of Ar, H and Sb were applied for excitation temperature (Texc) measurement. Assuming a Boltzmann distribution, the temperatures were calculated with the aid of the least squares method. Electron number density (ne) derived from Stark broadening of the Hβ line was found to be between 2.5x1015 and 0.57x1015 cm-3. The detection limits (DL) were determined for Hg and Sb. The influence of ethanol concentration in analyte solution and microwave power on measured parameters, was investigated. The results showed that Trot(OH) increased from 2970 to 3820 K while Trot(CH) decreased from 6100 to 4540 K with ethanol concentration in the solution, ranging from 10 to 90%. Under the same experimental conditions the excitation temperature for Ar, H and Sb varied in the following ranges: 5670-4800, 6190-3950 and 10500-7390 K, respectively. It was observed that element DL were significantly influenced by the presence of ethanol in the sample solution. The DL values for Hg and Sb were, as follows: 0.5-11 and 5.3-35 μg l-1, respectively

  4. Density of atoms in Ar*(3p{sup 5}4s) states and gas temperatures in an argon surfatron plasma measured by tunable laser spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, S.; Carbone, E. A. D.; Mullen, J. J. A. M. van der [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600MB Eindhoven (Netherlands); Sadeghi, N. [LIPhy, Universite Joseph Fourier and CNRS, UMR 5588, Grenoble F-38041 (France)

    2013-04-14

    This study presents the absolute argon 1 s (in Paschens's notation) densities and the gas temperature, T{sub g}, obtained in a surfatron plasma in the pressure range 0.6510 mbar, for which the pressure broadening can no more be neglected. T{sub g} is in the range of 480-750 K, increasing with pressure and decreasing with the distance from the microwave launcher. Taking into account the line of sight effects of the absorption measurements, a good agreement is found with our previous measurements by Rayleigh scattering of T{sub g} at the tube center. In the studied pressure range, the Ar(4 s) atom densities are in the order of 10{sup 16}-10{sup 18} m{sup -3}, increasing towards the end of the plasma column, decreasing with the pressure. In the low pressure side, a broad minimum is found around 10

  5. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu.

    Directory of Open Access Journals (Sweden)

    Hidefumi Uchiyama

    Full Text Available Electron paramagnetic resonance (EPR-spin trapping and flow cytometry were used to identify free radicals generated using argon-cold atmospheric plasma (Ar-CAP in aqueous solutions and intracellularly in comparison with those generated by X-irradiation. Ar-CAP was generated using a high-voltage power supply unit with low-frequency excitation. The characteristics of Ar-CAP were estimated by vacuum UV absorption and emission spectra measurements. Hydroxyl (·OH radicals and hydrogen (H atoms in aqueous solutions were identified with the spin traps 5,5-dimethyl-1-pyrroline N-oxide (DMPO, 3,3,5,5-tetramethyl-1-pyrroline-N-oxide (M4PO, and phenyl N-t-butylnitrone (PBN. The occurrence of Ar-CAP-induced pyrolysis was evaluated using the spin trap 3,5-dibromo-4-nitrosobenzene sulfonate (DBNBS in aqueous solutions of DNA constituents, sodium acetate, and L-alanine. Human lymphoma U937 cells were used to study intracellular oxidative stress using five fluorescent probes with different affinities to a number of reactive species. The analysis and quantification of EPR spectra revealed the formation of enormous amounts of ·OH radicals using Ar-CAP compared with that by X-irradiation. Very small amounts of H atoms were detected whereas nitric oxide was not found. The formation of ·OH radicals depended on the type of rare gas used and the yield correlated inversely with ionization energy in the order of krypton > argon = neon > helium. No pyrolysis radicals were detected in aqueous solutions exposed to Ar-CAP. Intracellularly, ·OH, H2O2, which is the recombination product of ·OH, and OCl- were the most likely formed reactive oxygen species after exposure to Ar-CAP. Intracellularly, there was no practical evidence for the formation of NO whereas very small amounts of superoxides were formed. Despite the superiority of Ar-CAP in forming ·OH radicals, the exposure to X-rays proved more lethal. The mechanism of free radical formation in aqueous solutions and

  6. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu.

    Science.gov (United States)

    Uchiyama, Hidefumi; Zhao, Qing-Li; Hassan, Mariame Ali; Andocs, Gabor; Nojima, Nobuyuki; Takeda, Keigo; Ishikawa, Kenji; Hori, Masaru; Kondo, Takashi

    2015-01-01

    Electron paramagnetic resonance (EPR)-spin trapping and flow cytometry were used to identify free radicals generated using argon-cold atmospheric plasma (Ar-CAP) in aqueous solutions and intracellularly in comparison with those generated by X-irradiation. Ar-CAP was generated using a high-voltage power supply unit with low-frequency excitation. The characteristics of Ar-CAP were estimated by vacuum UV absorption and emission spectra measurements. Hydroxyl (·OH) radicals and hydrogen (H) atoms in aqueous solutions were identified with the spin traps 5,5-dimethyl-1-pyrroline N-oxide (DMPO), 3,3,5,5-tetramethyl-1-pyrroline-N-oxide (M4PO), and phenyl N-t-butylnitrone (PBN). The occurrence of Ar-CAP-induced pyrolysis was evaluated using the spin trap 3,5-dibromo-4-nitrosobenzene sulfonate (DBNBS) in aqueous solutions of DNA constituents, sodium acetate, and L-alanine. Human lymphoma U937 cells were used to study intracellular oxidative stress using five fluorescent probes with different affinities to a number of reactive species. The analysis and quantification of EPR spectra revealed the formation of enormous amounts of ·OH radicals using Ar-CAP compared with that by X-irradiation. Very small amounts of H atoms were detected whereas nitric oxide was not found. The formation of ·OH radicals depended on the type of rare gas used and the yield correlated inversely with ionization energy in the order of krypton > argon = neon > helium. No pyrolysis radicals were detected in aqueous solutions exposed to Ar-CAP. Intracellularly, ·OH, H2O2, which is the recombination product of ·OH, and OCl- were the most likely formed reactive oxygen species after exposure to Ar-CAP. Intracellularly, there was no practical evidence for the formation of NO whereas very small amounts of superoxides were formed. Despite the superiority of Ar-CAP in forming ·OH radicals, the exposure to X-rays proved more lethal. The mechanism of free radical formation in aqueous solutions and an

  7. Epistatic and pleiotropic effects of polymorphisms in the fibrinogen and coagulation factor XIII genes on plasma fibrinogen concentration, fibrin gel structure and risk of myocardial infarction.

    Science.gov (United States)

    Mannila, Maria Nastase; Eriksson, Per; Ericsson, Carl-Göran; Hamsten, Anders; Silveira, Angela

    2006-03-01

    An intricate interplay between the genes encoding fibrinogen gamma (FGG), alpha (FGA) and beta (FGB), coagulation factor XIII (F13A1) and interleukin 6 (IL6) and environmental factors is likely to influence plasma fibrinogen concentration, fibrin clot structure and risk of myocardial infarction (MI). In the present study, the potential contribution of SNPs harboured in the fibrinogen, IL6 and F13A1 genes to these biochemical and clinical phenotypes was examined. A database and biobank based on 387 survivors of a first MI and population-based controls were used. Sixty controls were selected according to FGG 9340T > C [rs1049636] genotype for studies on fibrin clot structure using the liquid permeation method. The multifactor dimensionality reduction method was used for interaction analyses. We here report that the FGA 2224G > A [rs2070011] SNP (9.2%), plasma fibrinogen concentration (13.1%) and age (8.1%) appeared as independent determinants of fibrin gel porosity. The FGA 2224G > A SNP modulated the relation between plasma fibrinogen concentration and fibrin clot porosity. The FGG-FGA*4 haplotype, composed of the minor FGG 9340C and FGA 2224A alleles, had similar effects, supporting its reported protective role in relation to MI. Significant epistasis on plasma fibrinogen concentration was detected between the FGA 2224G > A and F13A1 Val34Leu [rs5985] SNPs (p FGG 9340T > C and FGB 1038G > A [rs1800791] SNPs appeared to interact on MI risk, explaining the association of FGG-FGB haplotypes with MI in the absence of effects of individual SNPs. Thus, epistatic and pleiotropic effects of polymorphisms contribute to the variation in plasma fibrinogen concentration, fibrin clot structure and risk of MI.

  8. Use of a nitrogen-argon plasma to improve adherence of sputtered titanium carbide coatings on steel

    Science.gov (United States)

    Brainard, W. A.; Wheeler, D. R.

    1979-01-01

    Friction and wear experiments on 440-C steel surfaces that had been RF-sputtered with titanium carbide when a small percentage of nitrogen was added to the plasma were conducted. X-ray photoelectron spectroscopy and X-ray diffraction were used to analyze the resultant coatings. Results indicate that a small partial pressure of nitrogen (about 0.5%) markedly improves the adherence, friction, and wear properties when compared with coatings applied on sputter-etched oxidized surfaces or in the presence of a small oxygen partial pressure. The improvements are related to the formation of an interface containing a mixture of the nitrides of titanium and iron, which are harder than their corresponding oxides.

  9. Impact of cold atmospheric pressure argon plasma on antibiotic sensitivity of methicillin-resistant Staphylococcus aureus strains in vitro.

    Science.gov (United States)

    Lührmann, Anne; Matthes, Rutger; Kramer, Axel

    2016-01-01

    Zielsetzung: Die antimikrobielle Wirksamkeit von kaltem Atmosphärendruckplasma (CAP), auch als gewebeverträgliches Plasma (TTP) bezeichnet, könnte eine aussichtsreiche Option zur Eradikation von Methicillin-empfindlichen ebenso wie von Methicillin-resistenten Staphylococcus aureus-Stämmen sein, die oft chronische Wunden kolonisieren. Bisher wurde der Einfluss von CAP auf die Antibiotikaempfindlichkeit von S. aureus kaum untersucht. Da eine Veränderung der Antibiotikaempfindlichkeit für die Wundbehandlung relevant sein könnte, sollte der Einfluss von CAP auf die Empfindlichkeit verschiedener S. aureus-Stämme gegen unterschiedliche Antibiotika untersucht werden.Methode: Im Agardiffusionstest wurden Antibiotikatestplättchen mit Cefuroxim, Gentamicin, Oxacillin, Vancomycin, Ciprofloxacin, Co-Trimoxazol, Clindamycin und Erythromycin eingesetzt. Die Teststämme wurden auf Agar ausplattiert und mit CAP exponiert, bevor die Testplättchen aufgelegt wurden. Nach 24 h Bebrütung wurden die Inhibitionszonen gemessen und statistisch auf Unterschiede geprüft.Ergebnisse: In den meisten Fällen war die Einfluss von CAP auf die Antibiotikaempfindlichkeit zu vernachlässigen. Für zwei Stämme wurde die Empfindlichkeit gegenüber β-Lactam-Antibiotika signifikant herabgesetzt. Schlussfolgerung: Da CAP die Antibiotikaempfindlichkeit beeinflussen kann, sollten vor beabsichtigter kombinierter lokaler CAP-Behandlung und gleichzeitiger systemischer Antibiotikagabe Interaktionen in vitro untersucht werden, um unerwünschte Kombinationseffekte auszuschließen.

  10. Spatial evolution of the electron energy distribution function in a low-pressure capacitively coupled plasma containing argon and krypton

    International Nuclear Information System (INIS)

    The spatial evolution of the electron energy distribution function (EEDF) in the axial direction of a capacitively coupled plasma with two parallel plate electrodes is investigated using an optical emission line-ratio method for Ar/Kr discharges. When the rf power is increased from 25 to 400 W at a pressure of 400 mTorr, we observe a transition from convex EEDFs to concave ones and a sharp increase in electron density, due to an α–γ mode transition, which is believed to be caused by the high-energy electrons originating in the high-voltage sheath. We also investigate the spatial evolution of the EEDF when the pressure is increased from 45 to 500 mTorr at a power of 100 W. The EEDF is uniform at pressures below 180 mTorr and becomes non-uniform at higher pressures, owing to the decrease in the energy relaxation length of the high-energy electrons. (paper)

  11. Interaction of nanosecond ultraviolet laser pulses with reactive dusty plasma

    Science.gov (United States)

    van de Wetering, F. M. J. H.; Oosterbeek, W.; Beckers, J.; Nijdam, S.; Gibert, T.; Mikikian, M.; Rabat, H.; Kovačević, E.; Berndt, J.

    2016-05-01

    Even though UV laser pulses that irradiate a gas discharge are small compared to the plasma volume (≲3%) and plasma-on time (≲6 × 10-6%), they are found to dramatically change the discharge characteristics on a global scale. The reactive argon-acetylene plasma allows the growth of nanoparticles with diameters up to 1 μm, which are formed inside the discharge volume due to spontaneous polymerization reactions. It is found that the laser pulses predominantly accelerate and enhance the coagulation phase and are able to suppress the formation of a dust void.

  12. Polymorphisms of the coagulation factor Ⅶ gene and its plasma levels in relation to acute cerebral infarction differences in allelic frequencies between Chinese Han and European populations

    Institute of Scientific and Technical Information of China (English)

    康文英; 王鸿利; 熊立凡; 王学锋; 储海燕; 璩斌; 刘湘帆; 尹俊; 段宝华; 王振义

    2004-01-01

    Background Coagulation factor Ⅶ (F Ⅶ) levels in plasma are usually related to ischemic heart disease (IHD) and cerebral infarction shares many of the risk factors related to IHD. Is there any relationship between factor Ⅶ and cerebral infarction? We investigated the relationship between F Ⅶ and acute cerebral infarction and reported genotype frequencies and allelic frequencies of FⅦ gene polymorphisms in the Chinese Han population.Methods We recruited 62 patients with acute cerebral infarction confirmed by magnetic resonance imaging (MRI) from Ruijin Hospital, and 149 age-matched patients clinically free of vascular disease to act as controls. All of them were unrelated, and were from the Chinese Han population. FⅦ coagulant activity (FⅦc) was determined using an clotting assay, activated FⅦ (FⅦa) and FⅦ Ag were assayed using enzyme immunoassay kits. The FⅦ gene polymorphisms to be detected included-401G/T, -402G/A, 5'F7A1/A2, IVS7 and R353Q. 5'F7 and IVS7 were revealed by means of a PCR and direct agarose gel electrophoresis. The rest were examined by a polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Results The results showed that FⅦc, FⅦAg and FⅦa were higher in the acute cerebral infarction group than in the control group (P<0.01, P<0.05, P<0.05, respectively). There were no significant differences in the genotype frequencies of FⅦ gene polymorphisms between the two groups. The allelic frequencies in the Chinese Han population were as follows: -401G/T (96.64/3.36), -402G/A (52.01/47.99), 5'F7A1/A2(96.64/3.36), IVS7 H5/H6/H7/H8 (0.34/52.35/46.98/0.34) and R353Q (95.64/4.36). There were significant differences (P<0.01, P<0.001, P<0.001, P<0.001, P<0.001, respectively) in these allelic frequencies between the Chinese Han and European populations.Conclusions The results indicate that increased plasma FⅦ levels may contribute to thrombosis in cerebral infarction. And there was no significant difference

  13. Titanium Dioxide Coatings Sprayed by a Water-Stabilized Plasma Gun (WSP) with Argon and Nitrogen as the Powder Feeding Gas: Differences in Structural, Mechanical and Photocatalytic Behavior

    Science.gov (United States)

    Ctibor, P.; Pala, Z.; Sedláček, J.; Štengl, V.; Píš, I.; Zahoranová, T.; Nehasil, V.

    2012-06-01

    Titanium dioxide coatings were sprayed by a water-stabilized plasma gun to form robust self-supporting bodies with a photocatalytically active surface. Agglomerated nanometric powder was used as a feedstock. In one case argon was used as a powder-feeding as well as coating-cooling gas whereas in the other case nitrogen was used. Stainless steel was used as a substrate and the coatings were released after the cooling. Over one millimeter thick self-supporting bodies were studied by XRD, HR-TEM, XPS, Raman spectroscopy, UV-VIS spectrophotometry and photocatalytic tests. Selected tests were done at the surface as well as at the bottom side representing the contact surface with the substrate during the spray process. Porosity was studied by image analysis on polished cross sections where also microhardness was measured. The dominant phase present in the sprayed samples was rutile, whereas anatase was only a minor component. The hydrogen content in the nitrogen-assisted coating was higher, but the character of the optical absorption edge remained the same for both samples. Photoelectron spectroscopy revealed differences in the character of the O1s peak between both samples. The photocatalytic activity was tested by decomposition of acetone at UV illumination, whereas also the end products—CO and CO2—were monitored. The nitrogen-assisted coating was revealed as a more efficient photocatalyst. Certain aspects of a thermal post-treatment on the coatings are discussed as well. Color and electrical conductivity are markedly changed at annealing at 760 °C, whereas only very small changes of the as-sprayed coating character correspond to annealing at 500 °C.

  14. Effects of nitrogen on the apoptosis of and changes in gene expression in human lymphoma U937 cells exposed to argon-based cold atmospheric pressure plasma.

    Science.gov (United States)

    Tabuchi, Yoshiaki; Uchiyama, Hidefumi; Zhao, Qing-Li; Yunoki, Tatsuya; Andocs, Gabor; Nojima, Nobuyuki; Takeda, Keigo; Ishikawa, Kenji; Hori, Masaru; Kondo, Takashi

    2016-06-01

    Cold atmospheric pressure plasma (CAP) is known as a source of biologically active agents, such as reactive oxygen species (ROS) and reactive nitrogen species (RNS). In the present study, we examined the effects of nitrogen (N2) on the apoptosis of and changes in gene expression in human lymphoma U937 cells exposed to argon (Ar)-CAP. Enormous amounts of hydroxyl (·OH) radicals in aqueous solution were produced using Ar‑CAP generated using a 20 kHz low frequency at 18 kV with a flow rate of 2 l/min. The increase in the levels of ·OH radicals was significantly attenuated by the addition of N2 to Ar gas. On the other hand, the level of total nitrate/nitrite in the supernatant was significantly elevated in the Ar + N2-CAP‑exposed U937 cells. When the cells were exposed to Ar‑CAP, a significant increase in apoptosis was observed, whereas apoptosis was markedly decreased in the cells exposed to Ar + N2-CAP. Microarray and pathway analyses revealed that a newly identified gene network containing a number of heat shock proteins (HSPs), anti-apoptotic genes, was mainly associated with the biological function of the prevention of apoptosis. Quantitative PCR revealed that the expression levels of HSPs were significantly elevated in the cells exposed to Ar + N2-CAP than those exposed to Ar‑CAP. These results indicate that N2 gas in Ar‑CAP modifies the ratio of ROS to RNS, and suppresses the apoptosis induced by Ar‑CAP. The modulation of gaseous conditions in CAP may thus prove to be useful for future clinical applications, such as for switching from a sterilizing mode to cytocidal effect for cancer cells.

  15. Effects of nitrogen on the apoptosis of and changes in gene expression in human lymphoma U937 cells exposed to argon-based cold atmospheric pressure plasma.

    Science.gov (United States)

    Tabuchi, Yoshiaki; Uchiyama, Hidefumi; Zhao, Qing-Li; Yunoki, Tatsuya; Andocs, Gabor; Nojima, Nobuyuki; Takeda, Keigo; Ishikawa, Kenji; Hori, Masaru; Kondo, Takashi

    2016-06-01

    Cold atmospheric pressure plasma (CAP) is known as a source of biologically active agents, such as reactive oxygen species (ROS) and reactive nitrogen species (RNS). In the present study, we examined the effects of nitrogen (N2) on the apoptosis of and changes in gene expression in human lymphoma U937 cells exposed to argon (Ar)-CAP. Enormous amounts of hydroxyl (·OH) radicals in aqueous solution were produced using Ar‑CAP generated using a 20 kHz low frequency at 18 kV with a flow rate of 2 l/min. The increase in the levels of ·OH radicals was significantly attenuated by the addition of N2 to Ar gas. On the other hand, the level of total nitrate/nitrite in the supernatant was significantly elevated in the Ar + N2-CAP‑exposed U937 cells. When the cells were exposed to Ar‑CAP, a significant increase in apoptosis was observed, whereas apoptosis was markedly decreased in the cells exposed to Ar + N2-CAP. Microarray and pathway analyses revealed that a newly identified gene network containing a number of heat shock proteins (HSPs), anti-apoptotic genes, was mainly associated with the biological function of the prevention of apoptosis. Quantitative PCR revealed that the expression levels of HSPs were significantly elevated in the cells exposed to Ar + N2-CAP than those exposed to Ar‑CAP. These results indicate that N2 gas in Ar‑CAP modifies the ratio of ROS to RNS, and suppresses the apoptosis induced by Ar‑CAP. The modulation of gaseous conditions in CAP may thus prove to be useful for future clinical applications, such as for switching from a sterilizing mode to cytocidal effect for cancer cells. PMID:27121589

  16. Spatial coagulation with bounded coagulation rate

    CERN Document Server

    Bailleul, Ismael

    2010-01-01

    We prove that the spatial coagulation equation with bounded coagulation rate is well-posed for all times in a given class of kernels if the convection term of the underlying particle dynamics has divergence bounded above by a negative constant. Multiple coagulations, fragmentation and scattering are also considered.

  17. Potentiation of thrombin generation in hemophilia A plasma by coagulation factor VIII and characterization of antibody-specific inhibition.

    Directory of Open Access Journals (Sweden)

    Bhavya S Doshi

    Full Text Available Development of inhibitory antibodies to coagulation factor VIII (fVIII is the primary obstacle to the treatment of hemophilia A in the developed world. This adverse reaction occurs in 20-30% of persons with severe hemophilia A treated with fVIII-replacement products and is characterized by the development of a humoral and neutralizing immune response to fVIII. Patients with inhibitory anti-fVIII antibodies are treated with bypassing agents including recombinant factor VIIa (rfVIIa. However, some patients display poor hemostatic response to bypass therapy and improved treatment options are needed. Recently, we demonstrated that fVIII inhibitors display widely variable kinetics of inhibition that correlate with their respective target epitopes. Thus, it was hypothesized that for antibodies that display slow rates of inhibition, supplementation of rfVIIa with fVIII would result in improved thrombin generation and be predictive of clinical responses to this novel treatment regimen. In order to test this hypothesis, 10 murine monoclonal antibodies (MAbs with non-overlapping epitopes spanning fVIII, differential inhibition titers, and inhibition kinetics were studied using a thrombin generation assay. Of the 3 MAbs with high inhibitory titers, only the one with fast and complete (classically defined as "type I" kinetics displayed significant inhibition of thrombin generation with no improvement upon supplementation of rfVIIa with fVIII. The other two MAbs that displayed incomplete (classically defined as "type II" inhibition did not suppress the potentiation of thrombin generation by fVIII. All antibodies that did not completely inhibit fVIII activity demonstrated potentiation of thrombin generation by the addition of fVIII as compared to rfVIIa alone. In conclusion, fVIII alone or in combination with rfVIIa corrects the thrombin generation defect produced by the majority of anti-fVIII MAbs better than single agent rfVIIa. Therefore, combined f

  18. Characterization of the gene for the a subunit of human factor XIII (plasma transglutaminase), a blood coagulation factor

    Energy Technology Data Exchange (ETDEWEB)

    Ichinose, A.; Davie, E.W. (Univ. of Washington, Seattle (USA))

    1988-08-01

    Factor XIII (plasma transglutaminase, fibrin stabilizing factor) is a glycoprotein that circulates in blood as a tetramer (a{sub 2}b{sub 2}) consisting of two a and two b subunits. The primary structures of the a and b subunits of human factor XIII have been reported by a combination of cDNA cloning and amino acid sequence analysis. To establish the gene structure of the a subunit for factor XIII, several human genomic libraries were screened by using the cDNA encoding the a subunit as a probe. Among {approx}5 {times} 10{sup 7} recombinant phage, 121 have been shown to contain an insert encoding a portion of the a subunit. Twenty-five unique clones were than characterized by restriction mapping, Southern blotting, and DNA sequencing. Overlapping clones encoding the a subunit of factor XIII span >160 kilobases. DNA sequence analysis revealed that the activation peptide released by thrombin, the active site cysteine region, the two putative calcium-binding regions, and the thrombin cleavage site leading to inactivation are encoded by separate exons. This suggest that the introns may separate the a subunit into functional and structural domains. A comparison of the amino acid sequence deduced from the genomic DNA sequence with those deduced from cDNA or determined by amino acid sequence analysis of the plasma and placental proteins revealed apparent amino acid polymorphisms in six positions of the polypeptide chain of the a subunit.

  19. Inflammation and coagulation

    NARCIS (Netherlands)

    M. Levi; T. van der Poll

    2010-01-01

    In the pathogenesis of sepsis, inflammation and coagulation play a pivotal role. Increasing evidence points to an extensive cross-talk between these two systems, whereby inflammation leads to activation of coagulation, and coagulation also considerably affects inflammatory activity. Molecular pathwa

  20. Modelling of a supersonic ICP argon-hydrogen expansion

    International Nuclear Information System (INIS)

    An expanding argon-hydrogen plasma is investigated by means of simulations. The model is a hydrodynamical model specific for plasma expansions, taking into account the conservation laws of mass, momentum and energy. The code includes the Rankine-Hugoniot relations to calculate shock jump conditions. Results are shown for the expansion from an inductively coupled plasma (ICP) with a separated Laval nozzle. The expansion discussed here is a 'weakly' under-expanding argon-hydrogen plasma. The results from the ICP expansion are verified with probe measurements

  1. Depleted Argon from Underground Sources

    International Nuclear Information System (INIS)

    Argon is a strong scintillator and an ideal target for Dark Matter detection; however 39Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in 39Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO2 well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO2. We first concentrate the argon locally to 3% in an Ar, N2, and He mixture, from the CO2 through chromatographic gas separation, and then the N2 and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO2 facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

  2. Treatment of Disseminated Intravascular Coagulation.

    Science.gov (United States)

    Makruasi, Nisa

    2015-11-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic activation of blood coagulation, generation of thrombin, and leading to disturbance of the microvasculature. In this article, definition and diagnostic criteria of DIC depend on the International Society of Thrombosis and Haemostasis (ISTH). There is no gold standard for diagnosis of DIC, only low quality evidence is used in general practice. Many diagnostic tests and repeated measurement are required. For the treatment of DIC, there is no good quality evidence. The most important treatment for DIC is the specific treatment of the conditions associated DIC. Platelets and/or plasma transfusion may be also necessary if indicated. Nevertheless, there is no gold standard for diagnosis and treatment of DIC, we use only low quality evidence in general practice.

  3. Disseminated intravascular coagulation in term and preterm neonates.

    Science.gov (United States)

    Veldman, Alex; Fischer, Doris; Nold, Marcel F; Wong, Flora Y

    2010-06-01

    Among critically ill patients, the risk of developing disseminated intravascular coagulation (DIC) is probably highest in neonates. Low plasma reserves in pro- and anticoagulant coagulation factors, intravascular volume contraction after birth, and a high incidence of hypoxia and sepsis in critically ill newborns rapidly lead to a decompensation of the coagulation system in this population. Global coagulation tests and single-factor plasma levels have to be interpreted in the context of age-corrected normal ranges. Platelet consumption and reduced protein C plasma levels have diagnostic value; the latter also has prognostic potential in neonates with DIC and sepsis. Therapeutic success relies heavily on reversal of the underlying condition. Some coagulation-specific therapies have been explored in small studies and case series with varying success and sometimes conflicting results. Therefore, larger controlled trials in this common and serious condition are urgently needed.

  4. Power Consideration for Pulsed Discharges in Potassium Seeded Argon

    Institute of Scientific and Technical Information of China (English)

    XIA Sheng-Guo; HE Jun-Jia; LIU Ke-Fu

    2007-01-01

    Minimization of energy consumed in plasma generation is critical for applications, in which a large volume of plasmas is needed. We suggest that a high electron density atmospheric pressure plasmas can be generated by pulsed discharges in potassium seeded argon at an elevated temperature with a very small power input. The ionization efficiency and power budget of pulsed discharges in such plasmas are analytically studied. The results show that ionization efficiency of argon, especially at small reduced electric field E/N (the ratio of the electric field to the gas number density), is improved effectively in the presence of small amount of potassium additives. Power input of pulsed discharge to sustain a prescribed average level of ionization in potassium seeded argon is three orders of magnitude lower than that in pure argon. Further, unlike in pure argon, it is found that very short high-voltage pulses with very high repetition rates are unnecessary in potassium seeded argon. A pulse with 100ns of pulse duration, 5kHz of repetition rate, and 2Td (1 Td = 1 ×10-21 Vm2) of E/N is enough to sustain an electron density of 10l9m-3 in 1 atm 1500 K Ar+0.1% K mixture, with a very small power input of about 0.08 × 104 W/m3.

  5. Polyphosphate, Platelets, and Coagulation

    OpenAIRE

    Travers, Richard J.; Smith, Stephanie A.; Morrissey, James H

    2015-01-01

    While we have understood the basic outline of the enzymes and reactions that make up the traditional blood coagulation cascade for many years, recently our appreciation of the complexity of these interactions has greatly increased. This has resulted in unofficial “revisions” of the coagulation cascade to include new amplification pathways and connections between the standard coagulation cascade enzymes, as well as the identification of extensive connections between the immune system and the c...

  6. Roles of argon seeding in energy confinement and pedestal structure in JT-60U

    International Nuclear Information System (INIS)

    The mechanism of improving energy confinement with argon seeding at high density has been investigated in JT-60U. Better confinement is sustained at high density by argon seeding accompanied by higher core and pedestal temperatures. The electron density profiles become flatter with increasing density in conventional H-mode plasmas, whereas peaked density profiles are maintained with argon seeding. Density peaking and dilution effects lower the pedestal density at a given averaged density. The pedestal density in the argon seeded plasmas, which is lower than that in plasmas with deuterium puff, enables the pedestal temperature to be higher, whereas the increase in the pedestal pressure with argon seeding is small. High pedestal temperature is a boundary condition for high core temperature through profile stiffness, which leads to better confinement with argon seeding. The density peaking is a key factor of sustaining better confinement in argon seeded H-mode plasmas. The radiative loss power density is predominantly enhanced in the edge region by argon puff. The role of argon seeding in the pedestal characteristics has also been examined. The pedestal width becomes larger continuously with edge collisionality, but is nearly independent of the presence of argon seeding. (paper)

  7. Hydrogen–argon plasma pre-treatment for improving the anti-corrosion properties of thin Al2O3 films deposited using atomic layer deposition on steel

    International Nuclear Information System (INIS)

    The effect of H2–Ar plasma pre-treatment prior to thermal atomic layer deposition (ALD) and plasma-enhanced atomic layer deposition (PEALD) of Al2O3 films on steel for corrosion protection was investigated. Time-of-flight secondary ion mass spectrometry and transmission electron microscopy were used to observe the changes in the interface. The electrochemical properties of the samples were studied with polarization measurements, and the coating porosities were calculated from the polarization results for easier comparison of the coatings. Prior to thermal ALD the plasma pre-treatment was observed to reduce the amount of impurities at the interface and coating porosity by 1–3 orders of magnitude. The anti-corrosion properties of the PEALD coatings could also be improved by the pre-treatment. However, exposure of the pre-treatment plasma activated steel surface to oxygen plasma species in PEALD led to facile oxide layer formation in the interface. The oxide layer formed this way was thicker than the native oxide layer and appeared to be detrimental to the protective properties of the coating. The best performance for PEALD Al2O3 coatings was achieved when, after the plasma pre-treatment, the surface was given time to regrow a thin protective interfacial oxide prior to exposure to the oxygen plasma. The different effects that thermal and plasma-enhanced ALD have on the substrate-coating interface were compared. The reactivity of the oxygen precursor was shown to have a significant influence on substrate surface in the early stages of film growth and thereafter also on the overall quality of the protective film. - Highlights: • Influence of H2–Ar plasma pre-treatment to ALD coatings on steel was studied. • The pre-treatment modified the coating–substrate interface composition and thickness. • The pre-treatment improved the barrier properties of the coatings

  8. Argon in action

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    Over the past few days, the SPS has been accelerating argon ions, which have started to be sent to the NA61/SHINE experiment. This operating mode, using a new type of ion, required a number of modifications to the accelerator.   Picture 1: a “super-cycle” of the SPS, featuring a proton cycle for the LHC, followed by an argon ion cycle for the North Area. Today, the accelerators are once again juggling particles and even performing completely new tricks. The SPS is supplying beams of argon ions for the first time, at energies never before achieved for this type of beam. They are destined for the NA61/SHINE experiment (see box) located in the North Area, which began receiving the beams on 11 February. Argon ions have a relatively large mass, as they consist of 40 nucleons, so they can be used in a similar way to lead ions. The main difficulty in accelerating them lies in the SPS, where the variation in acceleration frequency is limited. “The SPS was designed for a...

  9. Thermophysical properties of argon

    Energy Technology Data Exchange (ETDEWEB)

    Jaques, A.

    1988-02-01

    The entire report consists of tables of thermodynamic properties (including sound velocity, thermal conductivity and diffusivity, Prandtl number, density) of argon at 86 to 400/degree/K, in the form of isobars over 0.9 to 100 bars. (DLC)

  10. Spatial localization of bacteria controls coagulation of human blood by ‘quorum acting'

    OpenAIRE

    Kastrup, Christian J; Boedicker, James Q.; Pomerantsev, Andrei P.; Moayeri, Mahtab; Bian, Yao; Pompano, Rebecca R; Kline, Timothy R.; Sylvestre, Patricia; Shen, Feng; Leppla, Stephen H.; Tang, Wei-Jen; Ismagilov, Rustem F.

    2008-01-01

    Blood coagulation often accompanies bacterial infections and sepsis and is generally accepted as a consequence of immune responses. Though many bacterial species can directly activate individual coagulation factors, they have not been shown to directly initiate the coagulation cascade that precedes clot formation. Here we demonstrated, using microfluidics and surface patterning, that the spatial localization of bacteria substantially affects coagulation of human and mouse blood and plasma. Ba...

  11. The dielectronic satellite spectrum of helium-like argon: a contribution to the physics of highly-charged ions and plasma impurity transport

    International Nuclear Information System (INIS)

    Wavelengths and atomic parameters for the satellite spectrum to the 1s2 - 1s2p parent lines of Ar16+ have been calculated using a multiconfiguration intermediate coupling scheme with a statistical Thomas-Fermi potential. These data, together with radial charge state distributions given by an impurity transport code, are used to calculate theoretical spectra. The comparison with experimental X-ray spectra from the TFR tokamak plasma shows good agreement between calculated and observed wavelengths. The fitting of relative line intensities in the synthetic spectra to observed values improves the insight into plasma impurity transport

  12. Irradiation experiments on a mouse using a mild-plasma generator for medical applications

    International Nuclear Information System (INIS)

    Plasma technologies using an argon plasma coagulator have been used in endoscopic therapy to induce blood coagulation and ablate residual tumors. However, present devices have a risk of perforating the stomach wall during endoscopic submucosal dissection. Therefore, to reduce this risk, irradiation is performed for a limited time, which leads to incomplete cessation of bleeding and recurrence of residual tumors. Therefore, a device with greater controllability and safety is strongly desired for clinical applications. In this study, we have evaluated the irradiation efficiency of an atmospheric-pressure plasma jet based on a dielectric barrier discharge to control bleeding. Bleeding from a mouse femoral artery was induced, and then plasma was irradiated onto the bleeding area. Prompt coagulation in the disrupted blood vessel was observed, and there was no histological evidence of either burns or tissue necrosis caused by the plasma jet. These results suggest that postoperative scarring and adhesion may be prevented using the proposed plasma generator because of the reduced tissue damage. (author)

  13. Transition probabilities for argon I

    International Nuclear Information System (INIS)

    Transition probabilities for ArI lines have been calculated on the basis of the (j,k)-coupling scheme for more than 16000 spectral lines belonging to the transition arrays 4s-np (n=4 to n=9), 5s-np (n=5 to n=9), 6s-np (n=6 to n=9), 7s-np (n=8 to n=9), 4p-ns (n=5 to n=10), 5p-ns (n=6 to n=9), 6p-ns (n=7 to n=8), 4p-nd (n=3 to n=9), 5p-nd (n=4 to n=9), 3d-np (n=5 to n=9), 4d-np (n=6 to n=9), 5d-np (n=7 to n=9), 3d-nf (n=4 to n=9), 4d-nf (n=4 to n=9), 5d-nf (n=5 to n=9), 4f-nd (n=5 to n=9) 5f-nd (n=6 to n=9), 4f-ng (n=5 to n=9), 5f-ng (n=6 to n=9). Inso far as values by other authors exist, comparison is made with these values. It turns out that the results obtained in (j,k)-coupling are close to those obtained in intermediate coupling except for intercombination lines. For high principal and/or orbital quantum numbers the transition probabilities for a multiplet approach those of the corresponding transitions in atomic hydrogen. The calculated values are applied to construct a simplified argon-atom model, which reflects the real transition properties and which allows simplified but realistic non-equilibrium calculations for argon plasmas which deviate from local thermodynamic equilibrium (LTE)

  14. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    Science.gov (United States)

    Sun, Wen-Ting; Li, Guo; Li, He-Ping; Bao, Cheng-Yu; Wang, Hua-Bo; Zeng, Shi; Gao, Xing; Luo, Hui-Ying

    2007-06-01

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images.

  15. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    International Nuclear Information System (INIS)

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images

  16. Effect of different time on coagulation factors in fresh frozen plasma after thawing%不同放置时间对融化后新鲜冰冻血浆中凝血因子的影响

    Institute of Scientific and Technical Information of China (English)

    徐会芹

    2015-01-01

    Objective To investigate the effect of different time on coagulation factors in fresh frozen plasma after thawing.Methods The medicine blood by ACD B anticoagulated whole blood separation, preparation and fresh frozen plasma30,37℃ water bath melting and melt after 0,6,12,24h determination of prothrombin time (PT),activated partial thromboplastin time(APTT),fibrinogen(FIB),thrombin time (TT),coagulation factor FⅦ、FⅧ、FⅨ activity level.ResultsAfter the fresh frozen plasma,the PT,APTT,FIB,TT at different time points of the test results were not statistically different in 24 hours(P>0.05).Coagulation factor FⅦ and FⅧ changed with time and significantly decreased with the passage of time attenuation and blood immediate difference was statistically significant(P<0.05). FIX only when 12 hours had decreased,again after 24 hours.ConclusionFresh frozen plasma should be infused immediately after thawing,so as to guarantee the biological activity of coagulation factor and guarantee the effect of treatment.%目的:探讨不同放置时间对融化后新鲜冰冻血浆中凝血因子的影响。方法选择本院血站经ACD-B抗凝全血分离制备而成的新鲜冰冻血浆30份,37℃水浴融化,于融化后0、6、12、24h测定凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)、纤维蛋白(FIB)、凝血酶时间(TT)、凝血因子FⅦ、FⅧ、FⅨ活性水平。结果新鲜冷冻血浆融化后,PT、APTT、FIB、TT在24h内不同时间点测定结果,差异无统计学意义( P>0.05)。凝血因子FⅦ及FⅧ随时间的改变而有明显的降低,随着时间的推移衰减,与抽血即刻比较差异有统计学意义(P<0.05)。而FⅨ仅在12h的时候有一过性的下降,24h后又恢复。结论新鲜冰冻血浆在融化后应该立即输注,以保证凝血因子生物学活性,进一步保证治疗的效果。

  17. Plasma Sources for Medical Applications - A Comparison of Spot Like Plasmas and Large Area Plasmas

    Science.gov (United States)

    Weltmann, Klaus-Dieter

    2015-09-01

    Plasma applications in life science are currently emerging worldwide. Whereas today's commercially available plasma surgical technologies such as argon plasma coagulation (APC) or ablation are mainly based on lethal plasma effects on living systems, the newly emerging therapeutic applications will be based on selective, at least partially non-lethal, possibly stimulating plasma effects on living cells and tissue. Promising results could be obtained by different research groups worldwide revealing a huge potential for the application of low temperature atmospheric pressure plasma in fields such as tissue engineering, healing of chronic wounds, treatment of skin diseases, tumor treatment based on specific induction of apoptotic processes, inhibition of biofilm formation and direct action on biofilms or treatment of dental diseases. The development of suitable and reliable plasma sources for the different therapies requires an in-depth knowledge of their physics, chemistry and parameters. Therefore much basic research still needs to be conducted to minimize risk and to provide a scientific fundament for new plasma-based medical therapies. It is essential to perform a comprehensive assessment of physical and biological experiments to clarify minimum standards for plasma sources for applications in life science and for comparison of different sources. One result is the DIN-SPEC 91315, which is now open for further improvements. This contribution intends to give an overview on the status of commercial cold plasma sources as well as cold plasma sources still under development for medical use. It will discuss needs, prospects and approaches for the characterization of plasmas from different points of view. Regarding the manageability in everyday medical life, atmospheric pressure plasma jets (APPJ) and dielectric barrier discharges (DBD) are of special interest. A comprehensive risk-benefit assessment including the state of the art of commercial sources for medical use

  18. 原料血浆和凝血因子类产品中人细小病毒B19污染情况调查%Contamination of human parvovirus B19 in source plasma and coagulation factor products

    Institute of Scientific and Technical Information of China (English)

    贾俊婷; 马玉媛; 郭逸; 赵雄; 赵福广; 章金刚

    2015-01-01

    Objective To detect human parvovirus B19(B19V)DNA in source plasma pools and coagulation factor products and determine its prevalence and the level of contamination .Methods A pair of primers and a probe selected from the highly conserved sequences encoding the non-structural protein(NS1)of B19 were designed and synthesized.With the primer-probe combination ,source plasma pools and four types of coagulation factor products were determined for B 19V DNA by TaqMan real-time quantitative PCR.Results One-hundred and sixteen from 195 (59.49%) source plasma pools contained B19 DNA and concentrations up to 1.35 ×1010 copies/ml were measured.High frequencies of contamination were detected in factor Ⅷ (29 of 31; 93.55%), thrombin (10 of 10; 100%), fibrinogen (6 of 7; 85.71%) and prothrombin complex (8 of 9;88.89%).Conclusion These data show that B19V is a common contaminator in Chinese source plasma pools and coagulation factor products .Thus,B19V screening in Chinese source plasma seems desirable and significant for the safety of plasma derivatives in China .%目的:检测混合原料血浆和凝血因子类产品中人细小病毒B19(human parvovirus B19,B19病毒)核酸,分析我国原料血浆及凝血因子类产品中B19病毒的污染情况。方法针对B19病毒的保守区域NS1区合成引物及探针,采用TaqMan实时定量PCR法检测混合原料血浆和4类凝血因子类产品中B19病毒核酸。结果混合原料血浆的B19病毒核酸的阳性率为59.49%(116/195),最高浓度可达1.35×1010拷贝/ml。因子Ⅷ、凝血酶、纤维蛋白原以及凝血酶原复合物的阳性率分别为93.55%(29/31)、100%(10/10)、85.71%(6/7)和88.89%(8/9)。结论我国混合原料血浆与凝血因子类产品中B19病毒的污染率较高,有必要进行原料血浆的B19病毒筛查,对于保障血液制品的病毒安全性具有重要意义。

  19. Numerical Modeling of Plasmas in which Nanoparticles Nucleate and Grow

    Science.gov (United States)

    Agarwal, Pulkit

    Dusty plasmas refer to a broad category of plasmas. Plasmas such as argon-silane plasmas in which particles nucleate and grow are widely used in semiconductor processing and nanoparticle manufacturing. In such dusty plasmas, the plasma and the dust particles are strongly coupled to each other. This means that the presence of dust particles significantly affects the plasma properties and vice versa. Therefore such plasmas are highly complex and they involve several interesting phenomena like nucleation, growth, coagulation, charging and transport. Dusty plasma afterglow is equally complex and important. Especially, residual charge on dust particles carries special significance in several industrial and laboratory situations and it has not been well understood. A 1D numerical model was developed of a low-pressure capacitively-coupled plasma in which nanoparticles nucleate and grow. Polydispersity of particle size distributions can be important in such plasmas. Sectional method, which is well known in aerosol literature, was used to model the evolving particle size and charge distribution. The numerical model is transient and one-dimensional and self consistently accounts for nucleation, growth, coagulation, charging and transport of dust particles and their effect on plasma properties. Nucleation and surface growth rates were treated as input parameters. Results were presented in terms of particle size and charge distribution with an emphasis on importance of polydispersity in particle growth and dynamics. Results of numerical model were compared with experimental measurements of light scattering and light emission from plasma. Reasonable qualitative agreement was found with some discrepancies. Pulsed dusty plasma can be important for controlling particle production and/or unwanted particle deposition. In this case, it is important to understand the behavior of the particle cloud during the afterglow following plasma turn-off. Numerical model was modified to self

  20. Nitrogen metastable (N2(A3 Σu + )) in a cold argon atmospheric pressure plasma jet: Shielding and gas composition

    Science.gov (United States)

    Iseni, Sylvain; Bruggeman, Peter J.; Weltmann, Klaus-Dieter; Reuter, Stephan

    2016-05-01

    N 2 ( A 3 Σu + ) metastable species are detected and measured in a non-equilibrium atmospheric pressure plasma jet by laser induced fluorescence. A shielding device is used to change the ambient conditions additionally to the feeding gas composition. Varying the amount of N2 and air admixed to the feeding gas as well as changing the shielding gas from N2 to air reveals that the highest N 2 ( A 3 Σu + ) is achieved in the case of air admixtures in spite of the enhanced collisional quenching due to the presence of O2. The reasons for these observations are discussed in detail.

  1. Coagulation and Mental Disorders

    Directory of Open Access Journals (Sweden)

    Silvia Hoirisch-Clapauch

    2014-10-01

    Full Text Available The neurovascular unit is a key player in brain development, homeostasis, and pathology. Mental stress affects coagulation, while severe mental illnesses, such as recurrent depression and schizophrenia, are associated with an increased thrombotic risk and cardiovascular morbidity. Evidence indicates that the hemostatic system is involved to some extent in the pathogenesis, morbidity, and prognosis of a wide variety of psychiatric disorders. The current review focuses on emerging data linking coagulation and some psychiatric disorders.

  2. Coagulation properties of milk

    OpenAIRE

    Hallén, Elin

    2008-01-01

    Concentrations of the different proteins in milk are important for the outcome of the coagulation processes which yield our dairy products, whereas total milk protein content is a poor indicator of coagulation properties of milk. In order to design the milk protein composition to meet dairy processing requirements, selection for genetic variants of milk proteins have been proposed. This work aimed to study genetic milk protein polymorphism and its association with the detailed milk protein co...

  3. Liquid argon neutrino detectors

    CERN Document Server

    Battistoni, G

    2001-01-01

    The liquid argon imaging technique, as proposed for the ICARUS detector, offers the possibility to perform complementary and simultaneous measurements of neutrinos, as those of CERN to Gran Sasso beam (CNGS) and those from cosmic ray events. For the currently allowed values of the Super-Kamiokande results, the combination of both CNGS and atmospheric data will provide a precise determination of the oscillation parameters. Since one can observe and unambiguously identify nu /sub e/, nu /sub mu / and nu /sub tau / components, this technology allows to explore the full (3*3) mixing matrix. The same class of detector can be proposed for high precision measurements at a neutrino factory. (3 refs).

  4. Isentropic compression of argon

    Energy Technology Data Exchange (ETDEWEB)

    Veeser, L.R.; Ekdahl, C.A.; Oona, H. [and others

    1997-06-01

    The compression was done in an MC-1 flux compression (explosive) generator, in order to study the transition from an insulator to a conductor. Since conductivity signals were observed in all the experiments (except when the probe is removed), both the Teflon and the argon are becoming conductive. The conductivity could not be determined (Teflon insulation properties unknown), but it could be bounded as being {sigma}=1/{rho}{le}8({Omega}cm){sub -1}, because when the Teflon breaks down, the dielectric constant is reduced. The Teflon insulator problem remains, and other ways to better insulate the probe or to measure the conductivity without a probe is being sought.

  5. Emission and absorption spectroscopy study of Ar excited states in 13.56 MHz argon plasma operating at sub-atmospheric to atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Li, L. [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium); Nikiforov, A., E-mail: anton.nikiforov@ugent.be [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium); Institute of Solution Chemistry of the Russian Academy of Science, Academicheskaya St., 1, Ivanovo, 153045 (Russian Federation); Britun, N. [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Universite de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Snyders, R. [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Universite de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Materia Nova Research Centre, Parc Initialis, B-7000 Mons (Belgium); Leys, C. [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium)

    2015-05-01

    The densities of metastable and resonant states of Ar atoms are measured in high pressure Ar radio frequency discharge. Resonant absorption spectroscopy for the case of a low pressure spectral lamp and high-pressure plasma absorption lines is implemented for this purpose. The necessary generalizations for the high-pressure resonant absorption method are given. Absolute density of Ar 1s levels obtained at different RF input power and operating pressures are of the order of 10{sup 11} cm{sup −3}, which is in a good agreement with those reported in the literature. The population distribution on the Ar 2p (excited) levels, obtained from the optical emission spectroscopy, reveals strong deviation from thermal equilibrium for these levels in the high-pressure case. The generation of the Ar excited states in the studied discharges is compared to the previously reported results. - Highlights: • Strong non-equilibrium distribution of Ar 2p levels is observed. • The absolute number density of non-radiative Ar 1s states is determined by the easier and low cost spectral-lamp absorption method. • The modified absorption theory of Mitchell and Zemanski was used to obtain the absolute number density of Ar 1s states at high pressure. • The developed RF source with 5 cm long gap can be a possible alternative to micro-plasma working in Ar at atmospheric pressure.

  6. Emission and absorption spectroscopy study of Ar excited states in 13.56 MHz argon plasma operating at sub-atmospheric to atmospheric pressure

    International Nuclear Information System (INIS)

    The densities of metastable and resonant states of Ar atoms are measured in high pressure Ar radio frequency discharge. Resonant absorption spectroscopy for the case of a low pressure spectral lamp and high-pressure plasma absorption lines is implemented for this purpose. The necessary generalizations for the high-pressure resonant absorption method are given. Absolute density of Ar 1s levels obtained at different RF input power and operating pressures are of the order of 1011 cm−3, which is in a good agreement with those reported in the literature. The population distribution on the Ar 2p (excited) levels, obtained from the optical emission spectroscopy, reveals strong deviation from thermal equilibrium for these levels in the high-pressure case. The generation of the Ar excited states in the studied discharges is compared to the previously reported results. - Highlights: • Strong non-equilibrium distribution of Ar 2p levels is observed. • The absolute number density of non-radiative Ar 1s states is determined by the easier and low cost spectral-lamp absorption method. • The modified absorption theory of Mitchell and Zemanski was used to obtain the absolute number density of Ar 1s states at high pressure. • The developed RF source with 5 cm long gap can be a possible alternative to micro-plasma working in Ar at atmospheric pressure

  7. Change in blood coagulation indices as a function of the incubation period of plasma in a constant magnetic field. [considering heparin tolerance and recalcification

    Science.gov (United States)

    Yepishina, S. G.

    1974-01-01

    The influence of a constant magnetic field (CMF) with a strength of 250 and 2500 oersteds on the recalcification reaction and the tolerance of plasma to heparin was studied as a function of the exposure time of the plasma to the CMF. The maximum and reliable change in the activation of the coagulatory system of the blood was observed after a 20-hour incubation of the plasma in a CMF. As the exposure time increased, the recalcification reaction changed insigificantly; the difference between the mean arithmetic of the experiment and control values was not statistically reliable. The tolerance of the plasma to heparin as a function of the exposure time to the CMF of the plasma was considerably modified, an was statistically reliable.

  8. Estimation Using an Enhancement Factor on Non Local Thermodynamic Equilibrium Behavior of High-lying Energy Levels of Neutral Atom in Argon Radio-Frequency Inductively-Coupled Plasma.

    Science.gov (United States)

    Wagatsuma, Kazuaki; Satoh, Kozue

    2016-01-01

    This paper describes a plasma-diagnostic method using an enhancement factor on the Boltzmann distribution among emission lines of iron atom in an argon radio-frequency inductively-coupled plasma (ICP). It indicated that Boltzmann plots of the atomic lines having lower excitation energies (3.4 to 4.8 eV) were well fitted on a straight line while those having more than 5.5 eV deviated upwards from a linear relationship. This observation could be explained by the fact that ICP is not in a complete thermodynamic equilibrium between direct excitation to energy levels of iron atom, ionization of iron atom, and radiative decay processes to the ground state. Especially, the recombination of iron ion with captured electron should accompany cascade de-excitations between closely-spaced excited levels just below the ionization limit, the rates of which become slower as a whole; as a result, these high-lying levels might be more populated than the low-lying levels as if a different LTE condition coexists on the high energy side. This overpopulation could be quantitatively estimated using an enhancement factor (EF), which was a ratio of the observed intensity to the expected value extrapolated from the normal distribution on the low energy side. The EFs were generally small (less than 3); therefore, the cascade de-excitation process would slightly contribute to the population of these excited levels. It could be considered from variations of the EF that the overpopulation proceeded to a larger extent at lower radio-frequency forward powers, at higher flow rates of the carrier gas, or at higher observation heights. The reason for this is that the kinetic energy of energetic particles, such as electrons, becomes reduced under all of these plasma conditions, thus enabling the high-lying levels to be more populated by cascade de-excitation processes from iron ion rather than by collisional excitation processes with the energetic particles. A similar Boltzmann analysis using the EF

  9. Numerical study of breakdown pattern induced by an intense microwave under nitrogen and argon gases

    Science.gov (United States)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-07-01

    Filamentary plasma induced by microwave beam irradiation was reproduced in nitrogen and argon by combining fluid or particle plasma models with electromagnetic wave propagation. Transport coefficients used in the fluid model are estimated from particle simulation to maintain consistency of the breakdown structure between the fluid and particle models. A discrete structure was obtained using the one-dimensional (1D) fluid model, because a standing wave is generated in front of the plasma when the incident microwave beam is reflected by the overcritical plasma, which agrees with the breakdown structure obtained using the 1D particle model. A 2D plasma filament was also reproduced using the fluid model in nitrogen and argon. Reflection of the incident microwave in argon becomes stronger than that in nitrogen because of the denser argon plasma. Change in filament shape is induced in argon because the electric field is deformed at the plasma tip owing to stronger wave reflection from the neighboring filament. The propagation speed of the plasma front becomes larger in argon breakdown because of the larger ionization frequency and the larger diffusion coefficient.

  10. Populations of metastable and resonant argon atoms in radio frequency magnetron plasmas used for deposition of indium-zinc-oxide films

    International Nuclear Information System (INIS)

    This work reports optical absorption spectroscopy measurements of the number density of Ar atoms in resonant (3P1, 1P1) and metastable (3P2, 3P0) states in rf magnetron sputtering plasmas used for the deposition of ZnO-based thin films. While the density of Ar 3P2 and 3P0 was fairly independent of pressure in the range of experimental conditions investigated, the density of Ar 3P1 and 1P1 first sharply increased with pressure and then reached a plateau at values close to those of the 3P2 and 3P0 levels at pressures above about 50 mTorr. At such pressures, ultraviolet radiation from resonant states becomes trapped such that these levels behave as metastable states. For a self-bias voltage of -115 V and pressures in the 5-100 mTorr range, similar number densities of Ar resonant and metastable atoms were obtained for Zn, ZnO, and In2O3 targets, suggesting that, over the range of experimental conditions investigated, collisions between these excited species and sputtered Zn, In, and O atoms played only a minor role on the discharge kinetics. The metastable-to-ground state number density ratios were also fitted to the predictions of a global model using the average electron temperature, Te, as the only adjustable parameter. For all targets examined, the values of Te deduced from this method were in excellent agreement with those obtained from Langmuir probe measurements.

  11. Simulation of nanoparticle coagulation in radio-frequency C2H2/Ar microdischarges

    Science.gov (United States)

    Xiang-Mei, Liu; Qi-Nan, Li; Rui, Li

    2016-06-01

    The nanoparticle coagulation is investigated by using a couple of fluid models and aerosol dynamics model in argon with a 5% molecular acetylene admixture rf microdischarges, with the total input gas flow rate of 400 sccm. It co-exists with a homogeneous, secondary electron-dominated low temperature γ-mode glow discharges. The heat transfer equation and flow equation for neutral gas are taken into account. We mainly focused on investigations of the nanoparticle properties in atmospheric pressure microdischarges, and discussed the influences of pressure, electrode spacing, and applied voltage on the plasma density and nanoparticle density profiles. The results show that the characteristics of microdischarges are quite different from those of low pressure radio-frequency discharges. First, the nanoparticle density in the bulk plasma in microdischarges is much larger than that of low pressure discharges. Second, the nanoparticle density of 10 nm experiences an exponential increase as soon as the applied voltage increases, especially in the presheath. Finally, as the electrode spacing increases, the nanoparticle density decreased instead of increasing. Project supported by the Natural Science Foundation of Heilongjiang Province, China (Grant Nos. A2015011 and A2015010), the Postdoctoral Scientific Research Development Fund of Heilongjiang Province, China (Grant No. LBH-Q14159), the Program for Young Teachers Scientific Research in Qiqihar University (Grant No. 2014k-Z11), the National Natural Science Foundation of China (Grant No. 11404180), and the University Nursing Program for Yong Scholars with Creative Talents in Heilongjiang Province, China (Grant No. UNPYSCT-2015095).

  12. Interpreting coagulation assays.

    Science.gov (United States)

    Green, David

    2010-09-01

    The interpretation of coagulation assays requires knowledge of the principal clotting pathways. The activated partial thromboplastin time is sensitive to all hemostatic factors except FVII, whereas the prothrombin time reflects levels of prothrombin and FV, FVII, and FX. Using the two tests in concert is helpful in identifying hemophilia, the coagulopathy of liver disease, and disseminated intravascular coagulation. In addition, the activated partial thromboplastin time and prothrombin time are used for monitoring anticoagulant therapy with heparin and warfarin, respectively. Measurement of D-dimer is informative in patients suspected of having thrombotic disorders and determining the risk of thrombosis recurrence. Mixing tests distinguish clotting factor deficiencies from circulating anticoagulants such as heparin, the lupus anticoagulant, and antibodies directed against specific clotting factors. The modified Bethesda assay detects and provides an indication of the strength of FVIII inhibitors. However, interpreting the results of coagulation assays is not always straightforward, and expert consultation is occasionally required to resolve difficult clinical situations. PMID:20855988

  13. Thermophysical properties of multi-shock compressed dense argon.

    Science.gov (United States)

    Chen, Q F; Zheng, J; Gu, Y J; Chen, Y L; Cai, L C; Shen, Z J

    2014-02-21

    In contrast to the single shock compression state that can be obtained directly via experimental measurements, the multi-shock compression states, however, have to be calculated with the aid of theoretical models. In order to determine experimentally the multiple shock states, a diagnostic approach with the Doppler pins system (DPS) and the pyrometer was used to probe multiple shocks in dense argon plasmas. Plasma was generated by a shock reverberation technique. The shock was produced using the flyer plate impact accelerated up to ∼6.1 km/s by a two-stage light gas gun and introduced into the plenum argon gas sample, which was pre-compressed from the environmental pressure to about 20 MPa. The time-resolved optical radiation histories were determined using a multi-wavelength channel optical transience radiance pyrometer. Simultaneously, the particle velocity profiles of the LiF window was measured with multi-DPS. The states of multi-shock compression argon plasma were determined from the measured shock velocities combining the particle velocity profiles. We performed the experiments on dense argon plasmas to determine the principal Hugonoit up to 21 GPa, the re-shock pressure up to 73 GPa, and the maximum measure pressure of the fourth shock up to 158 GPa. The results are used to validate the existing self-consistent variational theory model in the partial ionization region and create new theoretical models. PMID:24559345

  14. Depleted argon from underground sources

    Energy Technology Data Exchange (ETDEWEB)

    Back, H.O.; /Princeton U.; Alton, A.; /Augustana U. Coll.; Calaprice, F.; Galbiati, C.; Goretti, A.; /Princeton U.; Kendziora, C.; /Fermilab; Loer, B.; /Princeton U.; Montanari, D.; /Fermilab; Mosteiro, P.; /Princeton U.; Pordes, S.; /Fermilab

    2011-09-01

    Argon is a powerful scintillator and an excellent medium for detection of ionization. Its high discrimination power against minimum ionization tracks, in favor of selection of nuclear recoils, makes it an attractive medium for direct detection of WIMP dark matter. However, cosmogenic {sup 39}Ar contamination in atmospheric argon limits the size of liquid argon dark matter detectors due to pile-up. The cosmic ray shielding by the earth means that Argon from deep underground is depleted in {sup 39}Ar. In Cortez Colorado a CO{sub 2} well has been discovered to contain approximately 500ppm of argon as a contamination in the CO{sub 2}. In order to produce argon for dark matter detectors we first concentrate the argon locally to 3-5% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation. The N{sub 2} and He will be removed by continuous cryogenic distillation in the Cryogenic Distillation Column recently built at Fermilab. In this talk we will discuss the entire extraction and purification process; with emphasis on the recent commissioning and initial performance of the cryogenic distillation column purification.

  15. The Liquid Argon Purity Demonstrator

    CERN Document Server

    Adamowski, M; Dvorak, E; Hahn, A; Jaskierny, W; Johnson, C; Jostlein, H; Kendziora, C; Lockwitz, S; Pahlka, B; Plunkett, R; Pordes, S; Rebel, B; Schmitt, R; Stancari, M; Tope, T; Voirin, E; Yang, T

    2014-01-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  16. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  17. UPLC-MRM Mass Spectrometry Method for Measurement of the Coagulation Inhibitors Dabigatran and Rivaroxaban in Human Plasma and Its Comparison with Functional Assays

    OpenAIRE

    Joachim Kuhn; Tatjana Gripp; Tobias Flieder; Marcus Dittrich; Doris Hendig; Jessica Busse; Cornelius Knabbe; Ingvild Birschmann

    2016-01-01

    Introduction The fast, precise, and accurate measurement of the new generation of oral anticoagulants such as dabigatran and rivaroxaban in patients' plasma my provide important information in different clinical circumstances such as in the case of suspicion of overdose, when patients switch from existing oral anticoagulant, in patients with hepatic or renal impairment, by concomitant use of interaction drugs, or to assess anticoagulant concentration in patients' blood before major surgery. M...

  18. Genotype–phenotype relationship of F7 R353Q polymorphism and plasma factor VII coagulant activity in Asian Indian families predisposed to coronary artery disease

    Indian Academy of Sciences (India)

    Jayashree Shanker; Ganapathy Perumal; Arindam Maitra; Veena S. Rao; B. K. Natesha; Shibu John; Sridhar Hebbagodi; Vijay V. Kakkar

    2009-12-01

    Elevated factor VII (FVII) level is a risk factor for coronary artery disease (CAD). We investigated the role of R353Q polymorphism in the F7 gene in 139 Indian families with CAD, comprising of 222 affected subjects, 105 unaffected subjects and 126 affected sibling pairs. Plasma per cent FVIIc activity (FVII.c activity) differed significantly across R353Q genotype ($P \\lt 0.0001$). Frequency of subjects with RR and QQ genotypes were higher in 4th quartile and 1st quartile of FVII.c activity, respectively ($P \\lt 0.0001$). F7 R353Q SNP was able to explain up to 7% of variation in FVII.c activity by regression analysis and an additive genetic component of variance of 28.04% by heritability analysis. Quantitative trait loci analysis showed suggestive linkage evidence of F7 SNP with per cent FVII.c activity (LOD score $-1.82$; $P = 0.002$). Individuals with RR and RQ genotypes carried an OR of 2.071 (95% c.i. = 1.506–2.850) and 2.472 (95% c.i. = 1.679–3.641), respectively, towards CAD risk. There was significant correlation of FVII.c activity with lipid markers, particularly among those with RR and RQ genotype after covariate adjustment. In conclusion, the F7 R353Q SNP appears to moderately influence plasma FVII.c activity and risk of CAD in Indians.

  19. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  20. Coagulation and Mental Disorders

    OpenAIRE

    Silvia Hoirisch-Clapauch; Antonio Egidio Nardi; Jean-Christophe Gris; Benjamin Brenner

    2014-01-01

    The neurovascular unit is a key player in brain development, homeostasis, and pathology. Mental stress affects coagulation, while severe mental illnesses, such as recurrent depression and schizophrenia, are associated with an increased thrombotic risk and cardiovascular morbidity. Evidence indicates that the hemostatic system is involved to some extent in the pathogenesis, morbidity, and prognosis of a wide variety of psychiatric disorders. The current review focuses on emerging data linking ...

  1. Coagulation inhibitors in inflammation.

    Science.gov (United States)

    Esmon, C T

    2005-04-01

    Coagulation is triggered by inflammatory mediators in a number of ways. However, to prevent unwanted clot formation, several natural anticoagulant mechanisms exist, such as the antithrombin-heparin mechanism, the tissue factor pathway inhibitor mechanism and the protein C anticoagulant pathway. This review examines the ways in which these pathways are down-regulated by inflammation, thus limiting clot formation and decreasing the natural anti-inflammatory mechanisms that these pathways possess. PMID:15787615

  2. Disseminated intravascular coagulation.

    Science.gov (United States)

    Gando, Satoshi; Levi, Marcel; Toh, Cheng-Hock

    2016-01-01

    Disseminated intravascular coagulation (DIC) is an acquired syndrome characterized by widespread intravascular activation of coagulation that can be caused by infectious insults (such as sepsis) and non-infectious insults (such as trauma). The main pathophysiological mechanisms of DIC are inflammatory cytokine-initiated activation of tissue factor-dependent coagulation, insufficient control of anticoagulant pathways and plasminogen activator inhibitor 1-mediated suppression of fibrinolysis. Together, these changes give rise to endothelial dysfunction and microvascular thrombosis, which can cause organ dysfunction and seriously affect patient prognosis. Recent observations have pointed to an important role for extracellular DNA and DNA-binding proteins, such as histones, in the pathogenesis of DIC. The International Society on Thrombosis and Haemostasis (ISTH) established a DIC diagnostic scoring system consisting of global haemostatic test parameters. This scoring system has now been well validated in diverse clinical settings. The theoretical cornerstone of DIC management is the specific and vigorous treatment of the underlying conditions, and DIC should be simultaneously managed to improve patient outcomes. The ISTH guidance for the treatment of DIC recommends treatment strategies that are based on current evidence. In this Primer, we provide an updated overview of the pathophysiology, diagnosis and management of DIC and discuss the future directions of basic and clinical research in this field. PMID:27250996

  3. Overview of the coagulation system

    Directory of Open Access Journals (Sweden)

    Sanjeev Palta

    2014-01-01

    Full Text Available Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ′coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  4. Tailoring the surface properties of polypropylene films through cold atmospheric pressure plasma (CAPP) assisted polymerization and immobilization of biomolecules for enhancement of anti-coagulation activity

    Science.gov (United States)

    Navaneetha Pandiyaraj, K.; Ram Kumar, M. C.; Arun Kumar, A.; Padmanabhan, P. V. A.; Deshmukh, R. R.; Bah, M.; Ismat Shah, S.; Su, Pi-Guey; Halleluyah, M.; Halim, A. S.

    2016-05-01

    Enhancement of anti-thrombogenic properties of polypropylene (PP) to avert the adsorption of plasma proteins (fibrinogen and albumin), adhesion and activation of the platelets are very important for vast biomedical applications. The cold atmospheric pressure plasma (CAPP) assisted polymerization has potential to create the specific functional groups such as Osbnd Cdbnd O, Cdbnd O, Csbnd N and Ssbnd S. on the surface of polymeric films using selective precursor in vapour phase to enhance anti-thrombogenic properties. Such functionalized polymeric surfaces would be suitable for various biomedical applications especially to improve the blood compatibility. The eventual aspiration of the present investigation is to develop the biofunctional coating onto the surface of PP films using acrylic acid (AAc) and polyethylene glycol (PEG) as a precursor in a vapour phase by incorporating specific functional groups for immobilization of biomolecules such as heparin (HEP), chitosan (CHI) and insulin (INS) on the surface of plasma modified PP films. The surface properties such as hydrophilicity, chemical composition, surface topography of the surface modified PP films were analyzed by contact angle (CA), Fourier transform infrared spectroscopy (FTIR), X-ray photo electron spectroscopy (XPS) and atomic force microscopy (AFM). Furthermore the anti-thrombogenic properties of the surface modified PP films were studied by in vitro tests which include platelet adhesion and protein adsorption analysis. It was found that the anti-thrombogenic properties of the PP films are effectively controlled by the CAPP grafting of AAc and PEG followed by immobilization of biomolecules of heparin, chitosan and insulin. The grafting and immobilization was confirmed by FTIR and XPS through the recognition of specific functional groups such as COOH, Csbnd O, Ssbnd S and Csbnd N. on the surface of PP film. Furthermore, the surface morphology and hydrophilic nature of the PP films also tailored

  5. A novel mutation in a patient with congenital coagulation factor Ⅻ deficiency

    Institute of Scientific and Technical Information of China (English)

    FENG Ying; YE Xu; PANG Ying; DAI Jing; WANG Xue-feng; ZHOU Xu-hong

    2008-01-01

    @@ Human coagulation factor Ⅻ(FⅫ),also called Hageman factor,is a plasma plycoprotein that is functionally deficient in individuals with Hageman trait:which is an inhefited trait discovered by chance during preoperative blood coagulation screening tests.FⅫ is a single-chain 596-amino-acid zymogen of a serine protease with an approximate molecular weight of 80 000.

  6. PHYSIOLOGY OF BLOOD COAGULATION (II)

    OpenAIRE

    B. Ţuţuianu

    2007-01-01

    Coagulation cascade was untill recently the only model used to explain the physiological and pathological reactions during clot formation. Dr. Maureane Hoffman and her team suggested a cell-based model for coagulation, which takes place (according to this model) in three phases: initiation, amplification and propagation. This theory does not deny the coagulation cascade. It only says that the leading role in the whole process is held by the cells and that the „intrinsic” and the „extinsic” pa...

  7. Fano factor in pure argon

    International Nuclear Information System (INIS)

    The Fano factor for 5.3 MeV alpha particles in pure argon has been measured with a gridded ionization chamber and estimated to be 0.20 (+0.01-0.02). The obtained value is consistent with the theoretical value if the contribution of elastic nuclear collisions to the Fano factor is taken into the consideration. There is no appreciable difference between the values for pure argon and for a gas mixture of Ar (10%)CH4 obtained in the previous measurement. (orig.)

  8. Disseminated intravascular coagulation in cancer patients

    NARCIS (Netherlands)

    M. Levi

    2009-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome that may complicate a variety of diseases, including malignant disease. DIC is characterized by widespread, intravascular activation of coagulation (leading to intravascular fibrin deposition) and simultaneous consumption of coagulation fact

  9. Argon gas concentration effects on nanostructured molybdenum nitride layer growth using 100 Hz pulsed dc glow discharge

    Science.gov (United States)

    Ikhlaq, U.; Ahmad, R.; Saleem, S.; Shah, M. S.; Umm-i-Kalsoom; Khan, N.; Khalid, N.

    2012-08-01

    The effect of argon concentration (10%-40%) on the surface properties of molybdenum is studied in nitrogen-argon mixture using 100 Hz pulsed dc glow discharge. The analysis is carried out by using X-ray diffractometer (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and Vickers microhardness tester to investigate surface properties of the nitrided samples. XRD results exhibit the formation of molybdenum nitrides. Crystallite size analysis and SEM morphology confirm the growth of nanostructured molybdenum nitride layers. Moreover, significant increase in surface hardness (by a factor of about two times) is found when the sample is treated for 30% argon in nitrogen-argon mixed plasma.

  10. Influences of fresh frozen plasma with different melting temperatures on coagulation factor and fibrinogen activity%新鲜冰冻血浆不同融解温度对凝血因子及纤维蛋白原活性的影响

    Institute of Scientific and Technical Information of China (English)

    赵凯

    2016-01-01

    目的:探讨不同融解温度对新鲜冰冻血浆凝血因子及纤维蛋白原活性的影响。方法随机选取40份新鲜冰冻血浆,分别在37℃、42℃、45℃水浴中充分进行融解,检测纤维蛋白原(FIB)、凝血Ⅷ因子、总蛋白(TP)含量,进行统计学分析。结果42℃组与37℃组新鲜冰冻血浆凝血Ⅷ因子、FIB、TP差异均无统计学意义(P>0.05)。45℃组与37℃组新鲜冰冻血浆FIB、TP差异均无统计学意义(P>0.05),45℃融解新鲜冰冻血浆凝血Ⅷ因子水平较37℃低,差异具有统计学意义(P<0.05)。结论随着融解温度升高,新鲜冰冻血浆凝血因子活性呈降低趋势,37℃为较佳融解温度。%Objective To explore the influences of fresh frozen plasma with different melting temperatures on coagulation factor and fibrinogen activity. Methods 40 samples of fresh frozen plasma were selected and sufficiently melted at 37℃, 42℃, 45℃ water bath respectively. The contents of fibrinogen (FIB), coagulation factor VIII, total protein (TP) were detected and statistically analyzed. Results There wad no difference in contents of FIB, coagulation factor VIII, TP between 42℃ group and 37℃ group (P>0.05). There wad no difference in contents of FIB, TP between 45℃ group and 37℃ group (P>0.05). The content of coagulation factor VIII in 45℃ group was lower than that in 37℃ group (P<0.05). Conclusion The coagulation factor activity of fresh frozen plasma was decreased when the melting temperature increased. 37℃ was the better choice of melting temperature.

  11. Usefulness of human coagulation and fibrinolysis assays in domestic pigs

    DEFF Research Database (Denmark)

    Münster, Anna-Marie Bloch; Olsen, Aage Kristian; Bladbjerg, Else-Marie

    2002-01-01

    of commercial human coagulation and fibrinolysis assays for use with porcine plasma. In total, 22 functional and immunologic assays were applied to plasma obtained from domestic pigs, and the following blood coagulation and fibrinolysis variables were measured: prothrombin time, activated partial thromboplastin...... that 11 of 12 functional assays, but only 3 of 10 immunoassays, were applicable to porcine plasma, and we determined the normal range of these variables. We conclude that human functional assays are useful in porcine plasma, whereas only a few immunologic assays can be used. However, precautions must...... be taken in interpretation of the results and in extrapolation toward human results because possible differences between porcine and human values can be due to species variations and/or methodologic errors....

  12. Spectroscopy of Argon Excited in an Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E

    2005-04-18

    Argon is one of the gases best investigated and most widely used in plasma discharge devices for a multitude of applications that range from wavelength reference standards to controlled fusion experiments. Reviewing atomic physics and spectroscopic problems in various ionization stages of Ar, the past use and future options of employing an electron beam ion trap (EBIT) for better and more complete Ar data in the x-ray, EUV and visible spectral ranges are discussed.

  13. Attainable superheat of argon-helium, argon-neon solutions.

    Science.gov (United States)

    Baidakov, Vladimir G; Kaverin, Aleksey M; Andbaeva, Valentina N

    2008-10-16

    The method of lifetime measurement has been used to investigate the kinetics of spontaneous boiling-up of superheated argon-helium and argon-neon solutions. Experiments were made at a pressure of p = 1.5 MPa and concentrations up to 0.33 mol% in the range of nucleation rates from 10 (4) to 10 (8) s (-1) m (-3). The homogeneous nucleation regime has been distinguished. With good agreement between experimental data and homogeneous nucleation theory in temperature and concentration dependences of the nucleation rate, a systematic underestimation by 0.25-0.34 K has been revealed in superheat temperatures over the saturated line attained by experiment as compared with theoretical values calculated in a macroscopic approximation. The revealed disagreement between theory and experiment is connected with the dependence of the properties of new-phase nuclei on their size.

  14. Coagulation/Flocculation of Tannery Wastewater Using Immobilized Chemical Coagulants

    OpenAIRE

    Q. Imran; M. A. Hanif; M. S. Riaz; S. Noureen; T. M. Ansari; Bhatti, H.N.

    2012-01-01

    Chemical coagulants were immobilized into bead form using sodium alginate to treat tannery wastewater samples. The used chemical coagulants were ammonium aluminium sulphate (NH4Al(SO4)2), aluminium sulphate (Al2(SO4)2, calcium carbonate (CaCO3), sodium citrate (Na3C6HsO7). The effect of the chemical coagulant dose and tannery wastewater pH was studied on wastewater electrical conductance (EC), total dissolved solids (TDS), sulphates, chlorides, phenolphthalein alkalinity, total alkalinity and...

  15. Trauma and Coagulation

    Directory of Open Access Journals (Sweden)

    Murat Yılmaz

    2011-08-01

    Full Text Available Bleeding and coagulation disorders related to trauma are pathological processes which are frequently seen and increase mortality. For the purpose, trauma patients should be protected from hypoperfusion, hypothermia, acidosis and hemodilution which may aggravate the increase in physiological responses to trauma as anticoagulation and fibrinolysis. Performing damage control surgery and resuscitation and transfusion of adequate blood and blood products in terms of amount and content as stated in protocols may increase the rate of survival. Medical treatments augmenting fibrin formation (fibrinogen, desmopressin, factor VIIa or preventing fibrin degradation (tranexamic acid have been proposed in selected cases but the efficacy of these agents in trauma patients are not proven. (Journal of the Turkish Society Intensive Care 2011; 9:71-6

  16. Separation of seven arsenic compounds by high performance liquid chromatography with on-line detection by hydrogen-argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, Erik Huusfeldt; Pritzl, G.;

    1992-01-01

    Seven molecular forms of arsenic were separated by anion- and cation-exchange high-performance liquid chromatography (HPLC) with on-line detection by flame atomic absorption spectrometry (FAAS). The interfacing was established by a vented poly(tetrafluoroethylene) capillary tubing connecting......-to-noise ratio of the on-line AAS detector was optimized. This involved the use of the hydrogen-argon-entrained air flame, a slotted tube atom trap in the flame for signal enhancement, electronic noise damping and a high-intensity light source. The detection limits in mu-g cm-3, using 100 mm3 injections...

  17. Separation of seven arsenic compounds by high-performance liquid chromatography with on-line detection by hydrogen–argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, E. H.; Pritzl, G.;

    1992-01-01

    Seven molecular forms of arsenic were separated by anion- and cation-exchange high-performance liquid chromatography (HPLC) with on-line detection by flame atomic absorption spectrometry (FAAS). The interfacing was established by a vented poly(tetrafluoroethylene) capillary tubing connecting......-to-noise ratio of the on-line AAS detector was optimized. This involved the use of the hydrogen-argon-entrained air flame, a slotted tube atom trap in the flame for signal enhancement, electronic noise damping and a high-intensity light source. The detection limits in mu-g cm-3, using 100 mm3 injections...

  18. Binocular indirect argon laser photocoagulator.

    OpenAIRE

    Mizuno, K

    1981-01-01

    The binocular indirect argon laser photocoagulator was newly designed to enable visualisation of the entire fundus during panretinal laser photocoagulation and to treat retinal tears immediately after buckling procedures of the sclera. The lamp housing of the binocular ophthalmoscope was remodelled and adjusted so that the laser beam and illuminating light are coaxial after leaving the ophthalmoscope. The blocking filter was permanently fixed in the eye-pieces to lighten the weight of the oph...

  19. Liquid Argon Barrel Cryostat Arrived

    CERN Multimedia

    Pailler, P

    Last week the first of three cryostats for the ATLAS liquid argon calorimeter arrived at CERN. It had travelled for 46 days over several thousand kilometers from Japan to CERN. During three years it has been fabricated by Kawasaki Heavy Industries Ltd. at Harima, close to Kobe, under contract from Brookhaven National Laboratory (BNL) of the U.S.. This cryostat consists of two concentric cylinders made of aluminium: the outer vacuum vessel with a diameter of 5.5 m and a length of 7 m, and the inner cold vessel which will contain the electromagnetic barrel calorimeter immersed in liquid argon. The total weight will be 270 tons including the detectors and the liquid argon. The cryostat is now located in building 180 where it will be equipped with 64 feed-throughs which serve for the passage of 122,880 electrical lines which will carry the signals of the calorimeter. After integration of the calorimeter, the solenoidal magnet of ATLAS will be integrated in the vacuum vessel. A final cold test of the cryostat inc...

  20. Obstetrical disseminated intravascular coagulation score.

    Science.gov (United States)

    Kobayashi, Takao

    2014-06-01

    Obstetrical disseminated intravascular coagulation (DIC) is usually a very acute, serious complication of pregnancy. The obstetrical DIC score helps with making a prompt diagnosis and starting treatment early. This DIC score, in which higher scores are given for clinical parameters rather than for laboratory parameters, has three components: (i) the underlying diseases; (ii) the clinical symptoms; and (iii) the laboratory findings (coagulation tests). It is justifiably appropriate to initiate therapy for DIC when the obstetrical DIC score reaches 8 points or more before obtaining the results of coagulation tests. Improvement of blood coagulation tests and clinical symptoms are essential to the efficacy evaluation for treatment after a diagnosis of obstetrical DIC. Therefore, the efficacy evaluation criteria for obstetrical DIC are also defined to enable follow-up of the clinical efficacy of DIC therapy.

  1. PHYSIOLOGY OF BLOOD COAGULATION (II

    Directory of Open Access Journals (Sweden)

    B. Ţuţuianu

    2007-07-01

    Full Text Available Coagulation cascade was untill recently the only model used to explain the physiological and pathological reactions during clot formation. Dr. Maureane Hoffman and her team suggested a cell-based model for coagulation, which takes place (according to this model in three phases: initiation, amplification and propagation. This theory does not deny the coagulation cascade. It only says that the leading role in the whole process is held by the cells and that the „intrinsic” and the „extinsic” pathways operate in parallel on different cell surfaces. Using this model, a better understanding of the reactions in vivo during coagulation is achieved, together with answers related to clinical-based questions like „why haemophiliacs bleed?”.

  2. Theoretical and experimental comparisons of Gamble 2 argon gas puff experiments

    International Nuclear Information System (INIS)

    A one-dimensional radiative MHD analysis of an imploding argon gas puff plasma is performed. The calculations are set up to approximate the conditions of a series of argon gas puff experiments that were carried out on the NRL Gamble II generator. Annular gas puffs (2.5 cm diameter) are imploded with a 1.2-MA peak driving current for different initial argon mass loadings. Comparisons are made with the experimental results for implosion times, K, L-shell x-ray emission, and energy coupled from the generator to the plasma load. The purpose of these calculations is to provide a foundation from which a variety of physical phenomena which influence the power and total energy of the x-ray emission can be analyzed. Comparisons with similar experimental and theoretical results for aluminum plasmas are discussed

  3. Composing Experimental Environment of PRIDE Argon cell

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Seonho; Jang, Yongkuk; Cho, Il Je [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In PRIDE depleted Uranium feed material and a depleted Uranium mixed with some surrogate material are used for performing engineering scale Pyroprocessing. PRIDE has to maintain inert atmosphere because of the characteristic of Electrolytic Reduction technology, Electro refining technology, Electrowinning technology. The impurity concentration of the Argon cell has to be under 50 ppm(Oxygen, moisture). Atmospheric pressure changes and temperature changes can affect the Argon cell's impurity concentration. In this paper, how to compose the Argon cell impurity concentration under 50 ppm to make the exact optimal experimental environment(Oxygen, moisture) will be introduced. Composing the exact optimal experimental environment by supplying Argon gas have been introduced in this paper. Continuously supplying Argon gas which is heavier than the Oxygen through the bottom of the Argon cell the oxygen eventually discharged through the high vent fan and lower the impurity concentration of Oxygen.

  4. Influence of easily ionised elements on the delayed responses of the emission intensities of an analyte in a power modulated U-shaped argon stabilised DC arc plasma with an aerosol supply

    Directory of Open Access Journals (Sweden)

    MIROSLAV KUZMANOVIC

    2005-09-01

    Full Text Available The current of a U-shaped argon stabilised DC arc was square modulated with a 40 Hz repetition frequency between 6 and 3 A. The delayed line intensity responses to the modulation of the arc current were investigated using calcium as a representative analyte. The intensities of both the atomic and ionic lines were monitored at different distances from the arc axis in the presence of various concentrations of the easily ionised element. Temporal evolutions were monitored on a millisecond time scale. It was found that the responses of the line intesity to the arc current change strongly depended on the observed radial position, especially in the vicinity of the arc axis. The obtained results showed a significant influence of even small amounts of the easily ionised element on the excitation and transport of the analyte and indicated a way of possibly improving the analytical capabilities of the excitation source.

  5. Argon Kα measurement on DIII endash D by Ross filters technique (abstract)

    International Nuclear Information System (INIS)

    Techniques to reduce the heat flux to the divertor plates in tokamak power plants and the consequent erosion of, and subsequent damage to the divertor target plates include the injection of impurities such as argon, that can dissipate the energy (through radiative or collisional processes) before it reaches the target plates. An important issue with this type of scheme is poisoning of the plasma core by the impurities introduced in the divertor region. Subsequently, there is a desire to measure the profiles of the injected impurities in the core. X-ray Ross filters with an effective narrow band pass centered on the argon Kα line at 3.2 keV, have been installed on two of the existing x-ray arrays on DIII endash D in order to help determine the argon concentration profiles. Emissivity profiles of the Kα lines and the emissivity profiles for the argon enhanced continuum can be inferred from the inverted filtered x-ray brightness signals if Te, ne, and Ar18+ profiles are known. The MIST code is used to couple the filtered x-ray signals to the time dependent measurements of Te and ne. Further, the Ar16+ profiles measured by charge transfer spectroscopy, are used as a constraint on the MIST code runs to calculate Ar18+ profiles and unfold the argon emissivity profiles. A discussion of the Ross filters, the DIII endash D argon data, and the data analysis scheme for inferring argon emissivity profiles will be discussed. Estimates of the total argon concentration in the core determined from this technique in DIII endash D argon puff experiments will be presented. copyright 1999 American Institute of Physics

  6. Levels of plasma D-dimer, activated coagulation factor Ⅶ and Ⅻ in patients with chronic urticaria%慢性荨麻疹患者血浆D二聚体、活化凝血因子Ⅶ及活化凝血因子Ⅻ水平的研究

    Institute of Scientific and Technical Information of China (English)

    王朵勤; 唐慧; 沈燕芸; 徐金华

    2015-01-01

    目的 探讨血浆D二聚体、活化凝血因子Ⅶ(FⅦa)及活化凝血因子Ⅻ(FⅫa)在慢性荨麻疹(CU)患者中的表达及其与CU发病的关系.方法 对50例CU患者及50例健康对照用干式免疫散射色谱法检测血浆D二聚体水平,用酶联免疫吸附法检测FⅦa及FⅫa的水平,并结合患者病情严重程度情况进行分析.对43例CU患者自体血浆皮肤试验(APST)及41例CU患者作自体血清皮肤试验(ASST)结果与其血浆D二聚体水平进行比较.结果 CU患者血浆中D二聚体及FⅦa的水平均明显高于健康对照组(P<0.05),前者升高水平与病情严重程度呈正相关(P<0.05);CU患者FⅫa水平与健康对照组比较,差异无统计学意义(P>0.05).APST(+)患者的D二聚体水平明显高于APST(-)患者(P<0.05),而ASST(+)患者D二聚体水平与ASST(-)患者比较,差异无统计学意义(P>0.05).结论 凝血机制与CU相关,外源性凝血途径起着作用,针对凝血机制的研究对于CU的病情评估和临床治疗具有一定的意义.%Objective To measure the levels of plasma D-dimer,activated coagulation factor Ⅶ (FⅦa) and activated clotting factor Ⅻ (FⅫa) in patients with chronic urticaria (CU),and to investigate their relationship with the occurrence of CU.Methods Venous blood samples were collected from 50 patients with CU and 50 healthy human controls.Dry-column immune scattering chromatography was performed to detect the plasma level of D-dimer,and enzyme-linked immunosorbent assay (ELISA) to measure the levels of FⅦa and FⅫa.In addition,autologous plasma skin test (APST) was conducted in 43 patients with CU,and autologous serum skin test (ASST) in 41 patients with CU.A correlation analysis was carried out between the above three parameters and disease severity as well as between the results of APST and ASST and plasma level of D-dimer.Results The levels of plasma D-dimer and F Ⅶa were significantly higher in patients with CU than in healthy

  7. Disseminated Intravascular Coagulation in Infectious Disease

    NARCIS (Netherlands)

    M. Levi; M. Schultz; T. van der Poll

    2010-01-01

    Severe infection and inflammation almost invariably lead to hemostatic abnormalities, ranging from insignificant laboratory changes to severe disseminated intravascular coagulation. Systemic inflammation as a result of severe infection leads to activation of coagulation, due to tissue factor-mediate

  8. Calcium Chloride as a Co-Coagulant

    OpenAIRE

    Hägg, Kristofer

    2015-01-01

    As populations continue to grow, the demand for fresh drinking water is increasing. This puts a lot of pressure on drinking water producers to strive for more efficient solutions and techniques. Many producers worldwide use surface water as a raw water source, which they often treat through coagulation and flocculation techniques. This is done by adding coagulant (e.g. metal coagulants), creating instability in the suspension, causing flocculation. In this work, PIX-311 (a FeCl3 coagulant pro...

  9. Modelling of Complex Plasmas

    Science.gov (United States)

    Akdim, Mohamed Reda

    2003-09-01

    Nowadays plasmas are used for various applications such as the fabrication of silicon solar cells, integrated circuits, coatings and dental cleaning. In the case of a processing plasma, e.g. for the fabrication of amorphous silicon solar cells, a mixture of silane and hydrogen gas is injected in a reactor. These gases are decomposed by making a plasma. A plasma with a low degree of ionization (typically 10_5) is usually made in a reactor containing two electrodes driven by a radio-frequency (RF) power source in the megahertz range. Under the right circumstances the radicals, neutrals and ions can react further to produce nanometer sized dust particles. The particles can stick to the surface and thereby contribute to a higher deposition rate. Another possibility is that the nanometer sized particles coagulate and form larger micron sized particles. These particles obtain a high negative charge, due to their large radius and are usually trapped in a radiofrequency plasma. The electric field present in the discharge sheaths causes the entrapment. Such plasmas are called dusty or complex plasmas. In this thesis numerical models are presented which describe dusty plasmas in reactive and nonreactive plasmas. We started first with the development of a simple one-dimensional silane fluid model where a dusty radio-frequency silane/hydrogen discharge is simulated. In the model, discharge quantities like the fluxes, densities and electric field are calculated self-consistently. A radius and an initial density profile for the spherical dust particles are given and the charge and the density of the dust are calculated with an iterative method. During the transport of the dust, its charge is kept constant in time. The dust influences the electric field distribution through its charge and the density of the plasma through recombination of positive ions and electrons at its surface. In the model this process gives an extra production of silane radicals, since the growth of dust is

  10. The coagulant response in sepsis and inflammation

    NARCIS (Netherlands)

    M. Levi

    2010-01-01

    Critically ill patients often have systemic activation of both inflammation and coagulation. Increasing evidence points to an extensive cross-talk between these two systems, whereby inflammation not only leads to activation of coagulation, but coagulation also considerably affects inflammatory activ

  11. 21 CFR 864.5400 - Coagulation instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....5400 Coagulation instrument. (a) Identification. A coagulation instrument is an automated...

  12. Involvement of coagulation and hemostasis in inflammatory bowel diseases.

    Science.gov (United States)

    Stadnicki, Antoni

    2012-09-01

    Inflammatory bowel diseases (IBD), Crohn's disease and ulcerative colitis (UC) are idiopathic, intestinal and systemic inflammatory disorders which are immunologically mediated with the activation of plasma proteolytic cascades. The activation of coagulation in IBD is related to the activity and colonic extension of the disease, but may still be persistent in a quiescent stage. Factor XIII seems to be as much a coagulation factor as a connective tissue factor which may contribute to intestinal healing. Fibrinolytic capacity is reduced in systemic circulation of IBD patients. Platelets activation is a feature of IBD which contributes to a pathogenic inflammatory sequel. There is evidence that coagulation activation may in turn mediate and amplify inflammatory cascades in IBD, especially via activating PARs related pathways. The etiology of thromboembolism in IBD seems to be multifactorial but is largely attributable to the coagulation activation and platelet aggregation during systemic inflammation. Thromboembolic (TE) complications in both Crohn's disease and UC appear to have at least 3-4 fold increased risk of developing compared to control patients. Currently, no single TE laboratory marker has a predictive value, but a recently developed endogenous thrombin potential test may have a potentially predicative value in IBD. At present, no interaction between IBD and inherited factors of thrombophilia has been found. An efficacy of heparin treatment in UC is still controversial, although heparin is safe in UC flare. Prophylactic anticoagulation against TE is currently not fully defined, however, high - risk patients should be considered for using a moderate dose of heparin. PMID:22272910

  13. Observation of Ω mode electron heating in dusty argon radio frequency discharges

    Energy Technology Data Exchange (ETDEWEB)

    Killer, Carsten; Bandelow, Gunnar; Schneider, Ralf; Melzer, André [Institut für Physik, Ernst-Moritz-Arndt-Universität Greifswald, 17489 Greifswald (Germany); Matyash, Konstantin [Universitätsrechenzentrum, Ernst-Moritz-Arndt-Universität Greifswald, 17489 Greifswald (Germany)

    2013-08-15

    The time-resolved emission of argon atoms in a dusty plasma has been measured with phase-resolved optical emission spectroscopy using an intensified charge-coupled device camera. For that purpose, three-dimensional dust clouds have been confined in a capacitively coupled rf argon discharge with the help of thermophoretic levitation. While electrons are exclusively heated by the expanding sheath (α mode) in the dust-free case, electron heating takes place in the entire plasma bulk when the discharge volume is filled with dust particles. Such a behavior is known as Ω mode, first observed in electronegative plasmas. Furthermore, particle-in-cell simulations have been carried out, which reproduce the trends of the experimental findings. These simulations support previous numerical models showing that the enhanced atomic emission in the plasma can be attributed to a bulk electric field, which is mainly caused by the reduced electrical conductivity due to electron depletion.

  14. Coagulation Changes During Graded Orhostatic Stress and Recovery

    Science.gov (United States)

    Goswami, Nandu; Cvirn, Gerhard; Schlagenhauf, Aaxel; Leschnik, Bettina; Koestenberger, Martin; Roessler, Andreas; Jantscher, Andreas; Waha, James Elvis; Wolf, Sabine; Vrecko, Karoline; Juergens, Guenther; Hinghofer-Szalkay, Helmut

    2013-02-01

    Background: Orthostatic stress has been introduced as a novel paradigm for activating the coagulation system. We examined whether graded orthostatic stress (using head up tilt, HUT + lower body negative pressure, LBNP) until presyncope leads to anti / pro-coagulatory changes and how rapidly they return to baseline during recovery. Methodology: Eight male subjects were enrolled in this study. Presyncopal runs were carried out using HUT + LBNP. At minute zero, the tilt table was brought from 0° (supine) to 70 ° head-up position for 4 min, after which pressure in the LBNP chamber was reduced to -15, -30, and -45 mm Hg every 4 min. At presyncope, the subjects were returned to supine position. Coagulatory responses and plasma mass density (for volume changes) were measured before, during and 20 min after the orthostatic stress. Whole blood coagulation was examined by means of thrombelastometry. Platelet aggregation in whole blood was examined by using impedance aggregometry. Thrombin generation parameters, prothrombin levels, and markers of endothelial activation were measured in plasma samples. Results: At presyncope, plasma volume was 20 % below the initial supine value. Blood cell counts, prothrombin levels, thrombin peak, endogenous thrombin potential (ETP), and tissue factor pathway inhibitor (TFPI) levels increased during the protocol, commensurate with hemoconcentration. The markers of endothelial activation (tissue factor, TF, tissue plasminogen activator, t-PA) and the markers of thrombin generation (Prothrombin fragments 1 and 2, F1+2, and thrombin-antithrombin complex, TAT) increased significantly. During recovery, all the coagulation parameters returned to initial supine values except F1 +2 and TAT. Conclusion: Head-up tilt/LBNP leads to activation of the coagulation system. Some of the markers of thrombin formation are still at higher than supine levels during recovery.

  15. 活化血浆凝固时间对评价血小板输注疗效价值的研究%Clinical Value of Activated Plasma Coagulation Time on Evaluation of Platelet Transfusion

    Institute of Scientific and Technical Information of China (English)

    陈明艳; 邱群芳; 席雅娟; 彭友堂

    2014-01-01

    Objective:To study the value of activated plasma coagulation time ( APCT) on evaluation of platelet transfusion.Method:Patients with blood disease and blood platelets count (PLT) was less than 50× 109 L-1 in our hospital from January to December 2011 were selected,in which 34 hemorrhage patients were selected as the observation group , and 34 patients without hemorrhage were selected as the control group . PLT,APCT of two groups were detected ,platelet transfusion was adopted in patients whose PLT was less than 10×109L-1,detected APCT,PLT after anticoagulation,then calculated corrected count increment (CCI) and practical platelet recovery (PPR).Result:There were three patients adopted platelet transfusion ,difference of PLT≤20×109L-1 and PLT≤10×109L-1 in hemorrhage patients had no statistical significance (p>0.05), APCT had shortened compared to that before platelet transfusion ,difference was statistically signficant ( p<0. 01);in observation group platelet transfusion was effective in 29 patients,APCT was less than 80s after 24h, CCI of 2 patients and PPR of 5 patients met the invalid standard of platelet transfusion ,in addition,platelet transfusion of 5 patients was invalid,APCT was more than 80s after 24h ,only 2 patients’ CCI and PPR metthe invalid standard of platelet transfusion .Conclusion:ACT not only can show the number and quality chan-ges of blood platelet well , but also evaluate the efficacy of platelet transfusion more comprehensively .%目的:对用活化血浆凝固时间( APCT)评价血小板输注疗效的价值进行研究。方法:在2011年1月至12月于我院住院治疗的血小板计数(PLT)均<50×109L-1的血液病患者中,出血的患者34例为观察组,不出血34例为对照组。对两组患者静脉采血测PLT、APCT;再对观察组和对照组中PLT <10×109L-1的患者给予血小板输注,抗凝后测其APCT、PLT,并计算校正血小板增高指数(CCI)和实际血小板回收率

  16. One more study of argon arc binding to pure tungsten cathode

    Science.gov (United States)

    Gadzhiev, M. Kh.; Sargsyan, M. A.; Tereshonok, D. V.; Tyuftyaev, A. S.

    2016-08-01

    Pyrometric and spectroscopic investigations of pure tungsten cathode in argon arc plasma discharge at atmospheric pressure are reported. The distribution of surface cathode temperature and the radial distribution of plasma temperature at different distance from the cathode tip were measured. We conducted a comparison between our work and other studies on arc discharges where cathodes from lanthanated (W-2% La2O3) and thoriated (W-2% ThO2) tungsten were used.

  17. Heat Transfer During Evaporation of Cesium From Graphite Surface in an Argon Environment

    Directory of Open Access Journals (Sweden)

    Bespala Evgeny

    2016-01-01

    Full Text Available The article focuses on discussion of problem of graphite radioactive waste formation and accumulation. It is shown that irradiated nuclear graphite being inalienable part of uranium-graphite reactor may contain fission and activation products. Much attention is given to the process of formation of radioactive cesium on the graphite element surface. It is described a process of plasma decontamination of irradiated graphite in inert argon atmosphere. Quasi-one mathematical model is offered, it describes heat transfer process in graphite-cesium-argon system. Article shows results of calculation of temperature field inside the unit cell. Authors determined the factors which influence on temperature change.

  18. Monoclonal antibodies to coagulation factor IX define a high-frequency polymorphism by immunoassays.

    OpenAIRE

    Smith, K. J.

    1985-01-01

    Monoclonal antibodies have been used to demonstrate a polymorphism of human plasma coagulation factor IX antigen in double antibody solid-phase immunoradiometric assays. This polymorphism is detected in an assay where a monoclonal antibody (A-1) adsorbed to microtiter wells is used to bind factor IX from diluted plasma samples. Plasma samples with the factor IX polymorphism have less than 0.2 U/ml of apparent antigen when tested with the A-1 antibody, while assays with other monoclonal antibo...

  19. Status and perspecitves of liquid argon calorimeters

    International Nuclear Information System (INIS)

    The status of liquid argon calorimeters is reviewed, and experience obtained with these devices is described. Future perspectives of the liquid ionization chamber technique in calorimetry are also discussed. (orig.)

  20. Clinical periodontics with the argon laser

    Science.gov (United States)

    Finkbeiner, R. L.

    1995-04-01

    The argon laser has proven to be a valuable tool for the thermodynamic debridement of the periodontal lesion, incisions and tissue fusion. Illustrations of clinical applications and discussion of laser parameters will be provided.

  1. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  2. Measurements on scintillation light from liquid argon

    International Nuclear Information System (INIS)

    It is shown that an argon calorimeter can operate as a scintillation detector, provided that xenon is added. With the addition of 170 ppm xenon a light yield of 70% has been obtained. In addition the light yield is determined under influence of an electric field, from differently ionising particles and by the use of aluminium mirrors acting as light guides. Finally first measurements with a photomultiplier working at liquid argon temperatures are reported. (orig.)

  3. Argon Laser Photoablation for Postburn Conjunctival Pigmentation

    Directory of Open Access Journals (Sweden)

    Seong Joon Ahn

    2014-01-01

    Full Text Available We report a case of an ocular burn injury from boiling water which resulted in conjunctival pigmentation, 1 week following injury. For cosmetic purposes, 2 sessions of argon laser photoablation were performed. One month after laser treatment, conjunctival pigmentation had been successfully removed and the patient was very satisfied with the results. Argon laser photoablation may be an effective way to remove postburn conjunctival pigmentation.

  4. Local effects of ECRH on argon transport at ASDEX upgrade

    International Nuclear Information System (INIS)

    Future deuterium-tritium magnetically confined fusion power plants will most probably rely an high-Z Plasma Facing Components (PFCs) such as tungsten. This choice is determined by the necessity of low erosion of the first wall materials (to guarantee a long lifetime of the wall components) and by the need to avoid the too high tritium wall retention of typical carbon based PFCs. The experience gathered at the ASDEX Upgrade (AUG) tokamak has demonstrated the possibility of reliable and high performance plasma operation with a full tungsten-coated first wall. The observed accumulation of tungsten which can lead to excessive radiation losses is mitigated with the use of Electron Cyclotron Resonance Heating (ECRH). Although this impurity control method is routinely performed at AUG, the underlying physics principles are still not clear. This thesis aims an providing further knowledge an the effects of ECRH an the transport of impurities inside the core plasma. The transport of argon has been therefore investigated in-depth in purely ECR heated L-mode (low-confinement) discharges. Studies an impurity transport in centrally ECR heated nitrogen-seeded H-mode (high-confinement) discharges have also been performed. To this scope, a new crystal X-ray spectrometer of the Johann type has been installed an AUG for argon concentration and ion temperature measurements. New methods for the experimental determination of the total argon density through the integrated use of this diagnostic and of the Soft X-Ray (SXR) diode arrays have been developed. This gives the possibility of evaluating the full profiles of the argon transport coefficients from the linear flux-gradient dependency of local argon density. In comparison to classical χ2-minimization methods, the approach proposed here delivers transport coefficients intrinsically independent of the modelling of periodic relaxation mechanisms such as those Lied to sawtooth MHD (Magneto-Hydro-Dynamic) activity. Moreover, the good

  5. Argon clusters embedded in helium nanodroplets.

    Science.gov (United States)

    da Silva, Filipe Ferreira; Bartl, Peter; Denifl, Stephan; Echt, Olof; Märk, Tilmann D; Scheier, Paul

    2009-11-14

    Electron impact ionization of argon clusters embedded in helium droplets is investigated. Superior mass resolution makes it possible to distinguish between nominally isobaric cluster ions. An abundance maximum for ArHe(12)(+) is unambiguously confirmed; the spectra also prove the formation of Ar(2)He(n)(+) complexes that had been claimed to fragment into pure Ar(2)(+). Distributions of larger argon cluster ions containing up to 60 atoms closely resemble distributions observed upon electron impact or photoionization of bare argon clusters; caging and evaporative cooling provided by the helium matrix do not suffice to quench fragmentation of the nascent argon cluster ions. Intriguing abundance anomalies are observed in distributions of argon cluster ions that contain water, nitrogen or oxygen impurities. The strong abundance of Ar(55)H(2)O(+), Ar(54)O(2)(+) and Ar(54)N(2)(+) contrasts with the virtual absence of slightly larger cluster ions containing the corresponding impurities. The features are probably related to enhanced cluster ion stability upon closure of the second icosahedral shell but the difference in magic numbers (54 versus 55) and the well-known reactivity of charged argon-nitrogen complexes suggest structural differences. PMID:19851558

  6. C-reactive protein prolongs blood coagulation time in phospholipids-dependent coagulation tests

    Directory of Open Access Journals (Sweden)

    L D Kozmin

    2003-01-01

    Full Text Available C-refctive protein prolongs blood coagulation time in phospholipids-dependent coagulation tests. O.P. Bliznukov, L.D. Kostin, A.J. Martinov, T.A. Lisitsina, T.M. Reshetnyak, V.J. Lauga Objective. To study influence of different CRP forms on blood clotting time in standard phospholipid clotting tests. Material and methods. Purified native CRP. monomeric CRP (0-1.6 M, immune complexes of native CRP and rabbit polyclonal anti-CRP antibodies (1.6 M were added to blood plasma of healthy donors. Blood clotting time was registered using optical coagulometer. Phospholipid dependent prothrombin time (PT, activated partial tromboplastin time (APTT, kaolin clotting time (KCT with kaolin and ellagic acid, dilute Russel viper venom time (dRVVT were determined. Results. Native CRP was able to increase blood clotting time in all mentioned clotting tests, excluding prothrombin time. CRP influence on blood clotting time showed a concentration dependence. Polyclonal rabbit anti-CRP antibodies had no inhibitory effect on CRP prolonged blood clotting time. Monomeric CRP (0-1.6 M had no influence on blood clotting time in all phospholipid-dependent clotting tests.

  7. [Ratio of erythrocyte and plasma in massive blood transfusion].

    Science.gov (United States)

    Wen, Xian-Hui; Liu, Feng-Xia; Zhang, Jun-Hua; Gui, Rong

    2014-06-01

    This study was purposed to explore the suitable ratio between fresh frozen plasma and erythrocyte by retrospective analysis of coagulation in patients with massive blood transfusion. The clinical data of 151 cases with massive blood transfusion from January 2011 to January 2013 were analyzed retrospectively. According to coagulation, patients were divided into coagulation normal group (138 cases) and coagulation dysfunction group (13 cases). Based on the ratio of 1:1 of fresh frozen plasma and erythrocyte, the patients were divided into high plasma group(2:1), medium plasma group (1:1) and low plasma (transfusion. The results showed that prothrombin time (PT), activated partial thromboplastin time (APTT) and thrombin time (TT) were prolonged, fibrinogen (FIB) level decreased significantly (all P transfusion 24 h; the high plasma and the medium plasma group of coagulation normal group had no significant changes in coagulation (P > 0.05); prothrombin time, activated partial thromboplastin time, thrombin time and fibrinogen level in the medium plasma and low plasma subgroup of coagulation dysfunction group after massive transfusion was still in abnormal levels (P > 0.05), coagulation function in high plasma subgroup was improved significantly (P transfusion, the ratio between fresh frozen plasma and erythrocyte is recommended to be 2:1 in patients of coagulation dysfunction in order to improve the patient's coagulation function and to reduce the incidence of adverse event, the ratio of fresh frozen plasma to erythrocyte is recommended to be 1:1 in patients with normal coagulation so as to reduce the dilutional coagulopathy and hypervolemia of blood.

  8. Thrombin-Responsive Gated Silica Mesoporous Nanoparticles As Coagulation Regulators.

    Science.gov (United States)

    Bhat, Ravishankar; Ribes, Àngela; Mas, Núria; Aznar, Elena; Sancenón, Félix; Marcos, M Dolores; Murguía, Jose R; Venkataraman, Abbaraju; Martínez-Máñez, Ramón

    2016-02-01

    The possibility of achieving sophisticated actions in complex biological environments using gated nanoparticles is an exciting prospect with much potential. We herein describe new gated mesoporous silica nanoparticles (MSN) loaded with an anticoagulant drug and capped with a peptide containing a thrombin-specific cleavage site. When the coagulation cascade was triggered, active thrombin degraded the capping peptidic sequence and induced the release of anticoagulant drugs to delay the clotting process. The thrombin-dependent response was assessed and a significant increase in coagulation time in plasma from 2.6 min to 5 min was found. This work broadens the application of gated silica nanoparticles and demonstrates their ability to act as controllers in a complex scenario such as hemostasis. PMID:26794474

  9. Gene Therapy for Coagulation Disorders.

    Science.gov (United States)

    Swystun, Laura L; Lillicrap, David

    2016-04-29

    Molecular genetic details of the human coagulation system were among the first successes of the genetic revolution in the 1980s. This information led to new molecular diagnostic strategies for inherited disorders of hemostasis and the development of recombinant clotting factors for the treatment of the common inherited bleeding disorders. A longer term goal of this knowledge has been the establishment of gene transfer to provide continuing access to missing or defective hemostatic proteins. Because of the relative infrequency of inherited coagulation factor disorders and the availability of safe and effective alternative means of management, the application of gene therapy for these conditions has been slow to realize clinical application. Nevertheless, the tools for effective and safe gene transfer are now much improved, and we have started to see examples of clinical gene therapy successes. Leading the way has been the use of adeno-associated virus-based strategies for factor IX gene transfer in hemophilia B. Several small phase 1/2 clinical studies using this approach have shown prolonged expression of therapeutically beneficial levels of factor IX. Nevertheless, before the application of gene therapy for coagulation disorders becomes widespread, several obstacles need to be overcome. Immunologic responses to the vector and transgenic protein need to be mitigated, and production strategies for clinical grade vectors require enhancements. There is little doubt that with the development of more efficient and facile strategies for genome editing and the application of other nucleic acid-based approaches to influence the coagulation system, the future of genetic therapies for hemostasis is bright. PMID:27126652

  10. Obstetric hemorrhage and coagulation: an update. Thromboelastography, thromboelastometry, and conventional coagulation tests in the diagnosis and prediction of postpartum hemorrhage.

    Science.gov (United States)

    de Lange, Natascha M; Lancé, Marcus D; de Groot, Reneé; Beckers, Erik A M; Henskens, Yvonne M; Scheepers, Hubertina C J

    2012-07-01

    Globally, postpartum hemorrhage (PPH) is the leading cause of maternal morbidity and mortality. In the current treatment of severe PPH, first-line therapy includes transfusion of packed cells and fresh-frozen plasma in addition to uterotonic medical management and surgical interventions. In persistent PPH, tranexamic acid, fibrinogen, and coagulation factors are often administered. Secondary coagulopathy due to PPH or its treatment is often underestimated and therefore remains untreated, potentially causing progression to even more severe PPH. In most cases, medical and transfusion therapy is not based on the actual coagulation state because conventional laboratory test results are usually not available for 45 to 60 minutes. Thromboelastography and rotational thromboelastometry are point-of-care coagulation tests. A good correlation has been shown between thromboelastometric and conventional coagulation tests, and the use of these in massive bleeding in nonobstetric patients is widely practiced and it has been proven to be cost-effective. As with conventional laboratory tests, there is an influence of fluid dilution on coagulation test results, which is more pronounced with colloid fluids. Fibrinogen seems to play a major role in the course of PPH and can be an early predictor of the severity of PPH. The FIBTEM values (in thromboelastometry, reagent specific for the fibrin polymerization process) decline even more rapidly than fibrinogen levels and can be useful for early guidance of interventions. Data on thromboelastography and thromboelastometry in pregnant women are limited, particularly during the peripartum period and in women with PPH, so more research in this field is needed. PMID:22926249

  11. Results of argon laser exposure of capillary hemangiomas of infancy--preliminary report.

    Science.gov (United States)

    Apfelberg, D B; Greene, R A; Maser, M R; Lash, H; Rivers, J L; Laub, D R

    1981-02-01

    Argon laser photocoagulation of capillary hemangiomas of infancy ("strawberry marks") has been described in three cases. Treatment in the first case was necessitated by repeated alarming hemorrhage. The second case was treated totally and resulted in immediate induced resolution of the hemangioma, which preceded (by 9 months) the spontaneous involution of an untreated control comparison area and resulted in virtually complete blanching without secondary deformity. The third case demonstrated the laser's ability to stop rapid growth immediately. Spontaneous involution then ensued naturally and was complete 12 months later. It should be emphasized that the argon laser is not recommended for the routine treatment of a normally spontaneously involuting hemangioma. Each case must be examined and the usual indications for intervention should be present. The argon laser has demonstrated the ability to coagulate vascular lesions such as port wine hemangiomas and telangiectasias and can be expected to have a similar favorable effect on the aggressive, rapidly expanding juvenile hemangioma, although further clinical documentation clearly remains to be demonstrated. PMID:7465667

  12. Potassium-argon/argon-40-argon-39 geochronology of Cenozoic alkali basalts from the South China Sea

    Institute of Scientific and Technical Information of China (English)

    YAN Quanshu; SHI Xuefa; YANG Yaomin; WANG Kunshan

    2008-01-01

    Based on the isotopic chronologic results of Cenozoic alkali basalts from the South China Sea,the characteristics of volcanic activi-ty of the South China Sea after spreading were studied.The potassium - argon ages of eight alkali basalt samples from the South China Sea,and the argon - argon ages of two samples among them are reported.Apparent ages of the whole rock are 3.80 to 7.91 Ma with an average value of 5.43 Ma (potassium- argon,whole rock),and there is little difference among samples at the same location,e.g.,4.76~5.78 Ma for location S04-12.The argon - argon ages for the two samples are 6.06 and 4.71 Ma,which lie within the age scope of potassium - argon method.The dating results indicate that rock-forming age is from late Miocene to Pli-ocene,which is consistent with erupting event for alkali basalts from adjacent regions of the South China Sea.Volcanic activities occur after the cessation of spreading of the South China Sea,which are controlled by lithospheric fault and the spreading center formed during the spreading period of the South China Sea.These dating results,combined with geochemical characteristics of these basalts,the published chronological data for the South China Sea and its adjacent regions,and the updated geophysical data near Hainan Island,suggest that after the cessation of spreading of the South China Sea,there occur widely distributing magmatic activities which primarily is alkali basalt,and the volcanic activity continues to Quaternary.The activity may be relative to Hainan mantle plume originated from core/mantle boundary.

  13. Effect of fibrinogen on blood coagulation detected by optical coherence tomography

    International Nuclear Information System (INIS)

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d1/e) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0–8 g L−1); and 2) native plasma with commercial Fbg added (0–8 g L−1). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels. (paper)

  14. Comparison of coagulation performance and floc properties using a novel zirconium coagulant against traditional ferric and alum coagulants.

    Science.gov (United States)

    Jarvis, Peter; Sharp, Emma; Pidou, Marc; Molinder, Roger; Parsons, Simon A; Jefferson, Bruce

    2012-09-01

    Coagulation in drinking water treatment has relied upon iron (Fe) and aluminium (Al) salts throughout the last century to provide the bulk removal of contaminants from source waters containing natural organic matter (NOM). However, there is now a need for improved treatment of these waters as their quality deteriorates and water quality standards become more difficult to achieve. Alternative coagulant chemicals offer a simple and inexpensive way of doing this. In this work a novel zirconium (Zr) coagulant was compared against traditional Fe and Al coagulants. The Zr coagulant was able to provide between 46 and 150% lower dissolved organic carbon (DOC) residual in comparison to the best traditional coagulant (Fe). In addition floc properties were significantly improved with larger and stronger flocs forming when the Zr coagulant was used with the median floc sizes being 930 μm for Zr; 710 μm for Fe and 450 μm for Al. In pilot scale experiments, a similar improved NOM and particle removal was observed. The results show that when optimised for combined DOC removal and low residual turbidity, the Zr coagulant out-performed the other coagulants tested at both bench and pilot scale.

  15. Fast-imaging and spectroscopic analysis of atmospheric argon streamers for large gap arc breakdown

    Science.gov (United States)

    Pachuilo, Michael; Stefani, Francis; Bengtson, Roger; Raja, Laxminarayan

    2014-10-01

    A non-equilibrium plasma source has been developed to assist in the low-voltage arc breakdown of large electrode gaps. The source consists of a dielectric embedded wire helically wound around a confining cylindrical quartz chamber. Annular electrodes cap the ends of the quartz chamber. An argon feed gas is used to provide a uniform environment and exhausts to ambient atmospheric conditions. A negative polarity 50 kV trigger pulse is applied to the embedded trigger wire to initiate the arc breakdown. Application of the trigger pulse produces a localized coronal discharges along the inner surface of the quartz tube. The corona provides seed electrons through which streamers propagate from one of the main discharge electrode along the quartz surface until it reaches the opposite electrode to bridge the gap. Once the gap is bridged a spark over occurs and robust arc discharge is formed in the chamber volume. Fast imaging of the streamer propagation establishes its velocity in the range of ~ 100 km/s. Spectroscopy of the streamer discharge in atmospheric argon has been conducted and electron temperature and number density estimated from a collision radiative model. Argon spectrum is dominated by neutral argon lines in the 650--950 nm range, and singly ionized argon lines are observed in the ultra-violet to near UV (300--400 nm). Research was performed in connection with AFOSR Contract FA9550-11-1-0062.

  16. Argon Collection And Purification For Proliferation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Achey, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event was a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.

  17. Quantifying interspecific coagulation efficiency of phytoplankton

    OpenAIRE

    J. L. S. Hansen; Kiørboe, Thomas

    1997-01-01

    Non-sticky latex beads and sticky diatoms were used as models to describe mutual coagulation between sticky and non-sticky particles. in mixed suspensions of beads and Thalassiosira nordenskjoeldii, both types of particles coagulated into mixed aggregates at specific rates, from which the interspecific coagulation efficiency could be calculated. Stickiness between beads and T. nordenskjoeldii was 50% of that of T. nordenskjoeldii in monospecific suspensions, and this ratio remained constant t...

  18. Dependence of Arc Plasma Dispersion Capability on its Temperature

    Institute of Scientific and Technical Information of China (English)

    CHEN Yun-Yun; SONG Yang; HE An-Zhi; LI Zhen-Hua

    2008-01-01

    @@ The relationship between the dispersion capability and the temperature of argon arc plasma at Iatm is deduced in view of the plasma's refractive index equation.The results indicate that argon arc plasma has a normal dispersion and its dispersion capability is nonlinear to the plasma's temperature in a wide range of temperature and wavelength region.According to the results of numerical calculation, the preferred optical methods are believed to be suitable for the diagnosis of argon arc plasma in different temperature regions.

  19. Attenuation of vacuum ultraviolet light in liquid argon

    CERN Document Server

    Neumeier, A; Oberauer, L; Potzel, W; Schönert, S; Dandl, T; Heindl, T; Ulrich, A; Wieser, J

    2015-01-01

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  20. Coagulation in patients with severe sepsis.

    Science.gov (United States)

    Levi, Marcel; Poll, Tom van der

    2015-02-01

    In the majority of patients with severe sepsis, systemic activation of coagulation is present. Increasing evidence points to an extensive cross-talk between coagulation and inflammation that may play an important role in the pathogenesis of sepsis. Inflammation not only leads to activation of coagulation, but coagulation also considerably affects inflammatory activity. Molecular pathways that contribute to inflammation-induced activation of coagulation have been precisely identified. Proinflammatory cytokines and other mediators are capable of activating the coagulation system and downregulating important physiological anticoagulant pathways. Activation of the coagulation system and ensuing thrombin generation is dependent on expression of tissue factor on activated mononuclear cells and endothelial cells, and is insufficiently counteracted by TFPI. Simultaneously, endothelial-bound anticoagulant mechanism, in particular the protein C system, is shutoff by proinflammatory cytokines. In addition, fibrin removal is severely inhibited, because of inactivation of the fibrinolytic system, caused by an upregulation of its main inhibitor, plasminogen activator inhibitor type 1 (PAI-1). Increased fibrin formation and impaired removal lead to (micro)vascular thrombosis, which may result in tissue ischemia and subsequent organ damage. The cornerstone of the management of coagulation in sepsis is the specific and vigorous treatment of the underlying disorder. Strategies aimed at the inhibition of coagulation activation may theoretically be justified and have been found beneficial in experimental and initial clinical studies. Heparin may be an effective anticoagulant approach and alternative strategies comprise restoration of physiological anticoagulant pathways. PMID:25590524

  1. Biomarkers of inflammation, coagulation and microbial translocation in HIV/HCV co-infected patients in the SMART study

    DEFF Research Database (Denmark)

    Peters, Lars; Neuhaus, Jacqueline; Duprez, Daniel;

    2014-01-01

    on levels of biomarkers of inflammation, coagulation and microbial translocation in HIV/HCV co-infected persons in the SMART study. STUDY DESIGN: All HIV/HCV co-infected persons with stored plasma at study entry and at six months of follow-up were included (N=362). D-dimer, IL-6, sCD14 and hepatic......-coagulation markers but the overall coagulation profile was not affected. Interruption of ART lead to a particularly pronounced increase in IL-6 levels in persons with elevated HA levels (p=0.01 for interaction between randomization group and continuous HA level). CONCLUSIONS: HIV/HCV co-infected persons...

  2. Dust grain coagulation modelling : From discrete to continuous

    Science.gov (United States)

    Paruta, P.; Hendrix, T.; Keppens, R.

    2016-07-01

    In molecular clouds, stars are formed from a mixture of gas, plasma and dust particles. The dynamics of this formation is still actively investigated and a study of dust coagulation can help to shed light on this process. Starting from a pre-existing discrete coagulation model, this work aims to mathematically explore its properties and its suitability for numerical validation. The crucial step is in our reinterpretation from its original discrete to a well-defined continuous form, which results in the well-known Smoluchowski coagulation equation. This opens up the possibility of exploiting previous results in order to prove the existence and uniqueness of a mass conserving solution for the evolution of dust grain size distribution. Ultimately, to allow for a more flexible numerical implementation, the problem is rewritten as a non-linear hyperbolic integro-differential equation and solved using a finite volume discretisation. It is demonstrated that there is an exact numerical agreement with the initial discrete model, with improved accuracy. This is of interest for further work on dynamically coupled gas with dust simulations.

  3. Coagulant and anticoagulant activities of Bothrops lanceolatus (Fer de lance) venom.

    Science.gov (United States)

    Lôbo de Araújo, A; Kamiguti, A; Bon, C

    2001-01-01

    Bothrops lanceolatus venom contains caseinolytic, phospholipase, esterase and haemorrhagic activities. We have investigated the coagulant and anticoagulant actions of B. lanceolatus venom on human citrated plasma and on purified plasma components. Although B. lanceolatus venom up to 50 microg/ml was unable to clot citrated plasma, at concentrations > or = 5 microg/ml the venom dose-dependently clotted purified human fibrinogen, indicating the presence of a thrombin-like enzyme. Human plasma (final concentration > or = 12.5%) dose-dependently inhibited the venom-induced fibrinogen clotting. This finding suggested that endogenous plasma protease inhibitors can affect the venom's action on fibrinogen. To investigate this possibility, B. lanceolatus venom was incubated with different plasma protease inhibitors and the activity on fibrinogen tested. alpha(2)-Macroglobulin and alpha(1)-antitrypsin did not interfere with the coagulant activity of the venom whereas the antithrombin-III/heparin complex partially inhibited this activity. A non-toxic, acidic phospholipase A(2) purified from B. lanceolatus venom prolonged the activated partial thromboplastin time in human plasma from 39.7+/-0.5 s (control with saline) to 60.2+/-0.9 s with 50 microg of PLA(2) (p<0.001), suggesting an anticoagulant activity associated with this enzyme. This anticoagulant activity may account for some of the effects of the venom on blood coagulation. PMID:10978756

  4. Increased mortality in systemic inflammatory response syndrome patients with high levels of coagulation factor VIIa

    NARCIS (Netherlands)

    Hyseni, A.; Kemperman, H.; De Lange, D. W.; de Groot, P. G.; Linssen, M.; Kesecioglu, J.; Lisman, T.; Roest, M.

    2013-01-01

    BackgroundThe tissue factor (TF)- Factor VIIa (FVIIa) complex has a pivotal role in inflammatory and coagulation responses in patients with systemic inflammatory response syndrome (SIRS) and sepsis. Because zymogen FVII (FVII) and FVIIa compete for binding to TF, their plasma levels determine if a c

  5. SC response characteristics of two kinds of coagulant

    Institute of Scientific and Technical Information of China (English)

    杨万东; 宋爽; 史惠祥

    2002-01-01

    Automatic coagulant dosage control with streaming current (SC) technique is in troduced inthis paper. Aluminum and ferric coagulants are widely used in surface water treatment. The SC response characteristics of P-AiCI3 aluminum coagulant and P-FeCI3 ferric coagulant were investigated in this work. Bench-scale water treatment results were obtained from jar tests including rapid mixing,flocculation and undisturbed sedimentation. Results showed that aluminum coagulant is more sensitive than ferric coagulant to SC response.

  6. SC response characteristics of two kinds of coagulant

    Institute of Scientific and Technical Information of China (English)

    杨万东; 宋爽; 史惠祥

    2002-01-01

    Automatic coagulant dosage control with streaming current (SC) technique is introduced in this paper. Aluminum and ferric coagulants are widely used in surface water treatment. The SC response characteristics of P-AlCl3 aluminum coagulant and P-FeCl3 ferric coagulant were investigated in this work. Bench-scale water treatment results were obtained from jar tests including rapid mixing, flocculation and undisturbed sedimentation. Results showed that aluminum coagulant is more sensitive than ferric coagulant to SC response.

  7. Matriptase activation connects tissue factor-dependent coagulation initiation to epithelial proteolysis and signaling.

    Science.gov (United States)

    Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric

    2016-06-23

    The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation. PMID:27114461

  8. Coagulation Biomarkers in Critically Ill Patients

    NARCIS (Netherlands)

    M. Levi; M. Schultz; T. van der Poll

    2011-01-01

    This article discusses coagulation biomarkers in critically ill patients where coagulation abnormalities occur frequently and may have a major impact on the outcome. An adequate explanation for the cause is important, since many underlying disorders may require specific treatment and supportive ther

  9. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    International Nuclear Information System (INIS)

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field

  10. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    CERN Document Server

    Creus, W; Amsler, C; Ferella, A D; Rochet, J; Scotto-Lavina, L; Walter, M

    2015-01-01

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.

  11. Investigation of coagulation activity of natural coagulants from seeds of different leguminose species

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2005-01-01

    Full Text Available The ability of seeds of plants: Phaseolus vulgaris, Robinia pseudoacacia Ceratonia siliqua and Amorpha fruticosa, to act as natural coagulants was tested using synthetic turbid water. This water was prepared by adding kaolin into tap water, just before the test. Active components were extracted from ground seeds with distilled water. The coagulation ability of this extract was assessed by the use of standard jar test measurements in water with various initial turbidity. Investigation of these natural coagulants was confirmed their positive coagulation activity. Of all plants that have been examined, the seed extract from Ceratonia siliqua appeared to be one of the most effective coagulants for water treatment. A dose of 20 mg/l of this coagulant resulted in 100% coagulation activity for clarification of water with 17.5 NTU initial turbidity.

  12. Textile wastewater purification through natural coagulants

    Science.gov (United States)

    Beltrán-Heredia, J.; Sánchez-Martín, J.; Rodríguez-Sánchez, M. T.

    2011-09-01

    A new coagulant obtained through polymerization of Acacia mearnsii de Wild tannin extract has been characterized in the removal of two dangerous dye pollutants: Alizarin Violet 3R and Palatine Fast Black WAN. This coagulant is lab-synthesized according to the etherification of tannins with glycidyltrimethylammonium chloride and formaldehyde and its performance in dye removal in terms of efficiency was high. Reasonably low coagulant dosages (ca. 50 mg L-1) reaches high capacity levels (around 0.8 for Alizarin Violet 3R and 1.6 for Palatine Fast Black WAN mg dye mg-1 of coagulant) and pH and temperature are not extremely affecting variables. The systems coagulant dyes were successfully modeled by applying the Langmuir hypothesis. q max and b parameters were obtained with an adjusted correlation factor ( r 2) above 0.8.

  13. Contraction ionization waves in the argon contracted discharge

    International Nuclear Information System (INIS)

    An investigation of ionization waves in the argon contracted discharge and a definition of their arising propagation mechanism accounting for the specificity of elementary pocesses characteristic of argon are presented. (author)

  14. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  15. Antiapoptotic activity of argon and xenon.

    Science.gov (United States)

    Spaggiari, Sabrina; Kepp, Oliver; Rello-Varona, Santiago; Chaba, Kariman; Adjemian, Sandy; Pype, Jan; Galluzzi, Lorenzo; Lemaire, Marc; Kroemer, Guido

    2013-08-15

    Although chemically non-reactive, inert noble gases may influence multiple physiological and pathological processes via hitherto uncharacterized physical effects. Here we report a cell-based detection system for assessing the effects of pre-defined gas mixtures on the induction of apoptotic cell death. In this setting, the conventional atmosphere for cell culture was substituted with gas combinations, including the same amount of oxygen (20%) and carbon dioxide (5%) but 75% helium, neon, argon, krypton, or xenon instead of nitrogen. The replacement of nitrogen with noble gases per se had no effects on the viability of cultured human osteosarcoma cells in vitro. Conversely, argon and xenon (but not helium, neon, and krypton) significantly limited cell loss induced by the broad-spectrum tyrosine kinase inhibitor staurosporine, the DNA-damaging agent mitoxantrone and several mitochondrial toxins. Such cytoprotective effects were coupled to the maintenance of mitochondrial integrity, as demonstrated by means of a mitochondrial transmembrane potential-sensitive dye and by assessing the release of cytochrome c into the cytosol. In line with this notion, argon and xenon inhibited the apoptotic activation of caspase-3, as determined by immunofluorescence microscopy coupled to automated image analysis. The antiapoptotic activity of argon and xenon may explain their clinically relevant cytoprotective effects. PMID:23907115

  16. Combined collision-induced dissociation and photo-selected reaction monitoring mass spectrometry modes for simultaneous analysis of coagulation factors and estrogens

    Institute of Scientific and Technical Information of China (English)

    Quentin Enjalbert; Marion Girod; Jérémy Jeudy; Jordane Biarc; Romain Simon; Rodolphe Antoine; Philippe Dugourd; Jérôme Lemoine; Arnaud Salvador

    2014-01-01

    Oral estrogens are directly associated with changes in plasma levels of coagulation proteins. Thus, the detection of any variation in protein concentrations due to estrogen contraceptives, by a simultaneous analysis of both coagulation proteins and estrogens, would be a very informative tool. In the present study, the merit of photo-selected reaction monitoring (SRM), a new analytical tool, was evaluated towards estrogens detection in plasma. Then, SRM and photo-SRM detection modes were combined for the simultaneous analysis of estrogen molecules together with heparin co-factor and factor XIIa, two proteins involved in the coagulation cascade. This study shows that photo-SRM could open new multiplexed analytical routes.

  17. Keeping argon under a graphene lid-Argon intercalation between graphene and nickel(111)

    Science.gov (United States)

    Späth, Florian; Gotterbarm, Karin; Amende, Max; Bauer, Udo; Gleichweit, Christoph; Höfert, Oliver; Steinrück, Hans-Peter; Papp, Christian

    2016-01-01

    We report on the intercalation of graphene grown on a Ni(111) crystal with argon. Argon is implanted in the Ni(111) crystal by ion bombardment before graphene growth, and diffuses to the surface during the growth of graphene at elevated temperatures. Graphene acts as an atomically thin barrier and keeps the argon underneath. We investigated this system with high resolution X-ray photoelectron spectroscopy. From our experiments we determined the mean quantities of argon under graphene. From our analysis, a simple model to determine the pressure under the graphene layer is presented. In our measurements, we find an increased thermal stability of the intercalated graphene as compared to non-intercalated graphene on Ni(111).

  18. Argon Laser Treatment of Strawberry Hemangioma in Infancy

    OpenAIRE

    Achauer, Bruce M.; Vander Kam, Victoria M.

    1985-01-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results.

  19. Argon laser treatment of strawberry hemangioma in infancy.

    Science.gov (United States)

    Achauer, B M; Vander Kam, V M

    1985-11-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results. PMID:4082569

  20. Enhanced coagulation for high alkalinity and micro-polluted water: the third way through coagulant optimization.

    Science.gov (United States)

    Yan, Mingquan; Wang, Dongsheng; Qu, Jiuhui; Ni, Jinren; Chow, Christopher W K

    2008-04-01

    Conventional coagulation is not an effective treatment option to remove natural organic matter (NOM) in water with high alkalinity/pH. For this type of water, enhanced coagulation is currently proposed as one of the available treatment options and is implemented by acidifying the raw water and applying increased doses of hydrolyzing coagulants. Both of these methods have some disadvantages such as increasing the corrosive tendency of water and increasing cost of treatment. In this paper, an improved version of enhanced coagulation through coagulant optimization to treat this kind of water is demonstrated. A novel coagulant, a composite polyaluminum chloride (HPAC), was developed with both the advantages of polyaluminum chloride (PACl) and the additive coagulant aids: PACl contains significant amounts of highly charged and stable polynuclear aluminum hydrolysis products, which is less affected by the pH of the raw water than traditional coagulants (alum and ferric salts); the additives can enhance both the charge neutralization and bridging abilities of PACl. HPAC exhibited 30% more efficiency than alum and ferric salts in dissolved organic carbon (DOC) removal and was very effective in turbidity removal. This result was confirmed by pilot-scale testing, where particles and organic matter were removed synergistically with HPAC as coagulant by sequential water treatment steps including pre-ozonation, coagulation, flotation and sand filtration.

  1. Identification of the biologically active liquid chemistry induced by a nonthermal atmospheric pressure plasma jet.

    Science.gov (United States)

    Wende, Kristian; Williams, Paul; Dalluge, Joe; Gaens, Wouter Van; Aboubakr, Hamada; Bischof, John; von Woedtke, Thomas; Goyal, Sagar M; Weltmann, Klaus-Dieter; Bogaerts, Annemie; Masur, Kai; Bruggeman, Peter J

    2015-01-01

    The mechanism of interaction of cold nonequilibrium plasma jets with mammalian cells in physiologic liquid is reported. The major biological active species produced by an argon RF plasma jet responsible for cell viability reduction are analyzed by experimental results obtained through physical, biological, and chemical diagnostics. This is complemented with chemical kinetics modeling of the plasma source to assess the dominant reactive gas phase species. Different plasma chemistries are obtained by changing the feed gas composition of the cold argon based RF plasma jet from argon, humidified argon (0.27%), to argon/oxygen (1%) and argon/air (1%) at constant power. A minimal consensus physiologic liquid was used, providing isotonic and isohydric conditions and nutrients but is devoid of scavengers or serum constituents. While argon and humidified argon plasma led to the creation of hydrogen peroxide dominated action on the mammalian cells, argon-oxygen and argon-air plasma created a very different biological action and was characterized by trace amounts of hydrogen peroxide only. In particular, for the argon-oxygen (1%), the authors observed a strong negative effect on mammalian cell proliferation and metabolism. This effect was distance dependent and showed a half life time of 30 min in a scavenger free physiologic buffer. Neither catalase and mannitol nor superoxide dismutase could rescue the cell proliferation rate. The strong distance dependency of the effect as well as the low water solubility rules out a major role for ozone and singlet oxygen but suggests a dominant role of atomic oxygen. Experimental results suggest that O reacts with chloride, yielding Cl2(-) or ClO(-). These chlorine species have a limited lifetime under physiologic conditions and therefore show a strong time dependent biological activity. The outcomes are compared with an argon MHz plasma jet (kinpen) to assess the differences between these (at least seemingly) similar plasma sources

  2. Miniature Coaxial Plasma injector Diagnostics by Beam Plasma Interaction

    International Nuclear Information System (INIS)

    A miniature coaxial gun has been used to study the interaction between plasma beam and low density plasma formed in glow discharge. The peak discharge current flow between the coaxial electrodes was 5.25 kA as a single pulse with pulse width of 60 mu. Investigations are carried out with argon gas at pressure 0.4 Torr. The plasma stream ejected from the coaxial discharge propagates in the neutral argon atoms with mean velocity of 1.2x105cm/s. The plasma stream temperature and density were 4.2 eV and 2.4x1013 cm-3respectively. An argon negative glow has been used as base plasma where its electron temperature and density were 2.2 eV and 6.2x107 cm-3 respectively. When the plasma stream propagates through the negative glow discharge region its velocity decreased to 8.8 x 104 cm/s and also the plasma electron temperature decreased to 3.1 eV, while the stream density remained the same. An excited wave appeared on the electric probe having frequency equal to the plasma frequency of the plasma under consideration. Simulation of the problem showed that this method could be applied for plasma diagnostics within the region of investigation. Those further studies for high temperature, dense, and magnetized plasma will be considered

  3. MeV Argon ion beam generation with narrow energy spread

    CERN Document Server

    Xu, Jiancai; Shen, Baifei; Zhang, Hui; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-01-01

    Laser driven particle acceleration has shown remarkable progresses in generating multi-GeV electron bunches and 10s of MeV ion beams based on high-power laser facilities. Intense laser pulse offers the acceleration field of 1012 Volt per meter, several orders of magnitude larger than that in conventional accelerators, enabling compact devices. Here we report that a highly-collimated argon ion beam with narrow energy spread is produced by irradiating a 45-fs fully-relativistic laser pulse onto an argon cluster target. The highly-charged (Argon ion with charge state of 16+) heavy ion beam has a minimum absolute energy spread of 0.19 MeV per nucleon at the energy peak of 0.39 MeV per nucleon. we identify a novel scheme from particle-in-cell simulations that greatly reduces the beam energy spread. The laser-driven intense plasma wakefield has a strong modulation on the ion beam in a way that the low energy part is cut off. The pre-accelerated argon ion beam from Coulomb explosion thus becomes more mono-energetic ...

  4. Coagulation-induced shedding of platelet glycoprotein VI mediated by factor Xa.

    Science.gov (United States)

    Al-Tamimi, Mohammad; Grigoriadis, George; Tran, Huy; Paul, Eldho; Servadei, Patricia; Berndt, Michael C; Gardiner, Elizabeth E; Andrews, Robert K

    2011-04-01

    This study evaluated shedding of the platelet collagen receptor, glycoprotein VI (GPVI) in human plasma. Collagen or other ligands induce metalloproteinase-mediated GPVI ectodomain shedding, generating approximately 55-kDa soluble GPVI (sGPVI) and approximately 10-kDa platelet-associated fragments. In the absence of GPVI ligands, coagulation of platelet-rich plasma from healthy persons induced GPVI shedding, independent of added tissue factor, but inhibitable by metalloproteinase inhibitor, GM6001. Factor Xa (FXa) common to intrinsic and tissue factor-mediated coagulation pathways was critical for sGPVI release because (1) shedding was strongly blocked by the FXa-selective inhibitor rivaroxaban but not FIIa (thrombin) inhibitors dabigatran or hirudin; (2) Russell viper venom that directly activates FX generated sGPVI, with complete inhibition by enoxaparin (inhibits FXa and FIIa) but not hirudin; (3) impaired GPVI shedding during coagulation of washed platelets resuspended in FX-depleted plasma was restored by adding purified FX; and (4) purified FXa induced GM6001-inhibitable GPVI shedding from washed platelets. In 29 patients with disseminated intravascular coagulation, mean plasma sGPVI was 53.9 ng/mL (95% confidence interval, 39.9-72.8 ng/mL) compared with 12.5 ng/mL (95% confidence interval, 9.0-17.3 ng/mL) in thrombocytopenic controls (n = 36, P coagulation-induced GPVI shedding via FXa down-regulates GPVI under procoagulant conditions. FXa inhibitors have an unexpected role in preventing GPVI down-regulation.

  5. Coagulation/flocculation/flotation/nanofiltration processes using Moringa Oleifera as coagulant of Eutrophized river

    OpenAIRE

    Camacho, Franciele P.; Bongiovani, Milene C.; Silva, Mariana O.; Coldebella, Priscila F.; Amorim, M. T. Pessoa de; Bergamasco, Rosângela

    2015-01-01

    This study investigated the efficiency of Moringa oleifera (MO) seeds as natural coagulant in coagulation/flocculation/dissolved air flotation (C/F/DAF), followed by nanofiltration (NF) for Microcystis protocystis and microcystin-LR removal. The methodology adopted in this work was performed in two steps: 1) coagulation/flocculation/dissolved air flotation (C/F/DAF) process using the MO extracted in saline solution of potassium chloride (KCl-1M) and sodium chloride (NaCl-1M) in op...

  6. Coagulation behavior of polyaluminum chloride:Effects of pH and coagulant dosage☆

    Institute of Scientific and Technical Information of China (English)

    Ning Wei; Zhongguo Zhang; Dan Liu; Yue Wu; Jun Wang; Qunhui Wang

    2015-01-01

    Coagulation mechanisms of polyaluminum chloride (PACl) at various dosages were studied using a conventional jar test at different final and initial pH values during treating kaolin suspension. The optimal final pH and dosages for PACl were obtained based on residual turbidity and zeta potential of flocs. The coagulation zones at various PACl dosages and solution pH values were developed and compared with those of alum. It is found that the optimal mechanism under acidic condition is charge neutralization, while alkaline condition wil facilitate the coagulation of PACl. Both charge neutralization coagulation and sweep coagulation can achieve high coagulation efficiency under the alkaline condition ranging from final pH 7.0 to 10.0. Stabilization, charge neutralization destabilization, restabilization and sweep zones occur successively with increasing PACl dosages with the final pH values fixed at 7.0 and 8.0, but restabilization zone disappears at final pH 10.0. When the final pH is not controlled and consequently decreases with increasing PACl dosage, no typical sweep zone can be observed and the coagulant efficiency decreases at high PACl dosage. It seems that the final pH is more meaningful than the initial pH for coagulation. Charge neutralization coagulation efficiency is dominated by zeta potential of flocs and PACl precipitates. The charge neutralization and sweep coagulation zones of PACl are broader in the ranges of coagulant dosage and pH than those of alum. The results are helpful for us to treat water and wastewa-ter using PACl and to understand the coagulation process of PACl.

  7. Study on the Efficacy of Abstergent Autologous Blood Transfusion Combined with Fresh Frozen Plasma in Preventing Coagulation Disorders after Operation%洗涤式自体血回输联合新鲜冰冻血浆预防术后凝血功能障碍

    Institute of Scientific and Technical Information of China (English)

    唐新桥; 陈建明; 李慧梁; 蔡丹; 周巧群; 罗旭倩

    2014-01-01

    【目的】探讨洗涤自体血回输联合使用新鲜冰冻血浆预防术后凝血障碍的疗效。【方法】选取2012年1月至2013年12月本院收治的大出血患者90例,按照患者的术中失血量大小,将其分为小量组(<400mL,n=50)、中量组(400~800mL,n=20)和大量组(>800mL,n=20)。根据回输血量多少与患者凝血功能的量化关系,制定联合新鲜冰冻血浆输注的具体方案。比较分析三组患者纤维蛋白原(FIB)、血小板(PLT)及凝血酶原时间(PT)变化情况。【结果】回输血液后三组患者机体FIB、PLT均较术前显著降低,PT明显延长(P<0.05);术后18h三组患者FIB、PLT均较回输血液后明显升高,PT显著缩短(P<0.05)。【结论】联合新鲜冰冻血浆输注的具体方案能提高洗涤自体血回输的安全性和实用性,有效预防凝血功能障碍的发生。%Objective To explore the efficacy of abstergent autologous blood transfusion combined with fresh frozen plasma in preventing coagulation disorders after operation .[Methods] Totally 90 patients with hemorrhea in our hospital from Jan .2012 to Sept .2013 were chosen .According to blood loss volume ,all pa-tients were divided into small volume group(800ml) .On the basis of the quantitative relation between blood transfusion volume and coagulation function of patients ,the concrete scheme about the combined fresh frozen plasma transfusion was made .Fi-brinogen(FIB) ,platelet(PLT) and prothrombin time(PT ) in 3 groups at different time point were analyzed and compared .[Results] Compared with before blood transfusion ,FIB and PLT in 3 groups after blood trans-fusion were decreased significantly and PT was prolonged obviously ( P <0 .05) .Compared with after blood transfusion ,FIB and PLT in 3 groups 18h after blood transfusion were increased obviously and PT was short-ened significantly( P < 0 .05) .[Conclusion]The concrete scheme about the

  8. Time-resolved characterization of a filamentary argon discharge at atmospheric pressure in a capillary using emission and absorption spectroscopy

    Science.gov (United States)

    Schröter, Sandra; Pothiraja, Ramasamy; Awakowicz, Peter; Bibinov, Nikita; Böke, Marc; Niermann, Benedikt; Winter, Jörg

    2013-11-01

    An argon/nitrogen (0.999/0.001) filamentary pulsed discharge operated at atmospheric pressure in a quartz tube is characterized using voltage-current measurements, microphotography, optical emission spectroscopy (OES) and absorption spectroscopy. Nitrogen is applied as a sensor gas for the purpose of OES diagnostic. The density of argon metastable atoms Ar(3P2) is determined using tunable diode laser absorption spectroscopy (TDLAS). Using a plasma chemical model the measured OES data are applied for the characterization of the plasma conditions. Between intense positive pulses the discharge current oscillates with a damped amplitude. It is established that an electric current flows in this discharge not only through a thin plasma filament that is observed in the discharge image but also through the whole cross section of the quartz tube. A diffuse plasma fills the quartz tube during a time between intense current pulses. Ionization waves are propagating in this plasma between the spike and the grounded area of the tube producing thin plasma channels. The diameter of these channels increases during the pause between the propagation of ionization waves probably because of thermal expansion and diffusion. Inside the channels electron densities of ˜2 × 1013 cm-3, argon metastable densities ˜1014 cm-3 and a reduced electric field about 10 Td are determined.

  9. Effects of Al-coagulant sludge characteristics on the efficiency of coagulants recovery by acidification.

    Science.gov (United States)

    Chen, Yi-Jui; Wang, Wen-May; Wei, Ming-Jun; Chen, Jiann-Long; He, Ju-Liang; Chiang, Kung-Yuh; Wu, Chih-Chao

    2012-12-01

    This study evaluated the effects of Al-coagulant sludge characteristics on the efficiency ofcoagulant recovery by acidification with H2SO4. Two sludge characteristics were studied: types of coagulant and textures of the suspended solid in raw water. The coagulant types are aluminium sulphate and polyaluminium chloride (PACl); the textures of the suspended solid are sand-based and clay-based. Efficiency of aluminium recovery at a pH of 2 was compared for different sludges obtained from water treatment plants in Taiwan. The results showed that efficiency of aluminium recovery from sludge containing clayey particles was higher than that from sludge containing sandy particles. As for the effect of coagulant types, the aluminium recovery efficiency for sludge using PACl ranged between 77% and 100%, whereas it ranged between 65% and 72% for sludge using aluminium sulphate as the coagulant. This means using PACl as the coagulant could result in higher recovery efficiency of coagulant and be beneficial for water treatment plants where renewable materials and waste reduction as the factors for making decisions regarding plant operations. However, other metals, such as manganese, could be released with aluminium during the acidification process and limit the use of the recovered coagulants. It is suggested that the recovered coagulants be used in wastewater treatment processes. PMID:23437650

  10. Blood coagulation factor XII drives adaptive immunity during neuroinflammation via CD87-mediated modulation of dendritic cells.

    Science.gov (United States)

    Göbel, Kerstin; Pankratz, Susann; Asaridou, Chloi-Magdalini; Herrmann, Alexander M; Bittner, Stefan; Merker, Monika; Ruck, Tobias; Glumm, Sarah; Langhauser, Friederike; Kraft, Peter; Krug, Thorsten F; Breuer, Johanna; Herold, Martin; Gross, Catharina C; Beckmann, Denise; Korb-Pap, Adelheid; Schuhmann, Michael K; Kuerten, Stefanie; Mitroulis, Ioannis; Ruppert, Clemens; Nolte, Marc W; Panousis, Con; Klotz, Luisa; Kehrel, Beate; Korn, Thomas; Langer, Harald F; Pap, Thomas; Nieswandt, Bernhard; Wiendl, Heinz; Chavakis, Triantafyllos; Kleinschnitz, Christoph; Meuth, Sven G

    2016-01-01

    Aberrant immune responses represent the underlying cause of central nervous system (CNS) autoimmunity, including multiple sclerosis (MS). Recent evidence implicated the crosstalk between coagulation and immunity in CNS autoimmunity. Here we identify coagulation factor XII (FXII), the initiator of the intrinsic coagulation cascade and the kallikrein-kinin system, as a specific immune cell modulator. High levels of FXII activity are present in the plasma of MS patients during relapse. Deficiency or pharmacologic blockade of FXII renders mice less susceptible to experimental autoimmune encephalomyelitis (a model of MS) and is accompanied by reduced numbers of interleukin-17A-producing T cells. Immune activation by FXII is mediated by dendritic cells in a CD87-dependent manner and involves alterations in intracellular cyclic AMP formation. Our study demonstrates that a member of the plasmatic coagulation cascade is a key mediator of autoimmunity. FXII inhibition may provide a strategy to combat MS and other immune-related disorders. PMID:27188843

  11. Argon laser irradiation of the otolithic organ

    Energy Technology Data Exchange (ETDEWEB)

    Okuno, T.; Nomura, Y.; Young, Y.H.; Hara, M. (Univ. of Tokyo (Japan))

    1990-12-01

    An argon laser was used to irradiate the otolithic organs of guinea pigs and cynomolgus monkeys. After stapedectomy, the argon laser (1.5 W x 0.5 sec/shot) irradiated the utricle or saccule without touching the sensory organs. The stapes was replaced over the oval window after irradiation. The animals used for acute observation were killed immediately for morphologic studies; those used for long-term observation were kept alive for 2, 4, or 10 weeks. Acute observation revealed that sensory and supporting cells were elevated from the basement membrane only in the irradiated area. No rupture of the membranous labyrinth was observed. Long-term observation revealed that the otolith of the macula utriculi had disappeared in 2-week specimens. The entire macula utricili had disappeared in 10-week specimens. No morphologic changes were observed in cochlea, semicircular canals, or membranous labyrinth. The saccule showed similar changes.

  12. Abnormal epidermal changes after argon laser treatment

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, R.A.; Knobler, R.M.; Aberer, E.; Klein, W.; Kocsis, F.; Ott, E. (Univ. of Vienna (Austria))

    1991-02-01

    A 26-year-old woman with a congenital port-wine stain on the forehead was treated three times at 2-month intervals with an argon laser. Six months after the last treatment, moderate blanching and mild scaling confined to the treated area was observed. A biopsy specimen of the treated area revealed a significant decrease in ectatic vessels. However, epidermal changes similar to those of actinic keratosis with disorganized cell layers and marked cytologic abnormalities were seen. Analysis of peripheral blood lymphocytes for a defect in DNA repair was negative. Multiple, argon laser-induced photothermal effects may be responsible for the changes observed in our case and may lead to premalignant epidermal transformation.

  13. Explanation of the memory effect in argon

    Directory of Open Access Journals (Sweden)

    Marković Vidosav

    2005-01-01

    Full Text Available Memory effect - the long time variation of the electrical breakdown time delay on the relaxation time td (τ was observed in argon 24 hours after relaxation times and explained by the long-lived metastable states remaining from the preceding glow. However, the quenching processes reducing the effective lifetime of metastable states several orders of magnitude below that relevant for the time scale of observation were neglected. By applying approximate gas phase models it was found that the early afterglow kinetics up to hundreds of milliseconds is dominated by the decay of molecular argon ions Ar2+ and the approximate value of their ambipolar diffusion coefficient is determined. After that, nitrogen atoms present as impurities and recombined on the cathode surface and/or field emission determine the breakdown time delay down to the cosmic rays and natural radioactivity level.

  14. [New oral anticoagulants - influence on coagulation tests].

    Science.gov (United States)

    Simeon, L; Nagler, M; Wuillemin, W A

    2014-01-01

    The new oral anticoagulants (NOACs) represent alternative antithrombotic agents for prophylaxis and therapy of thromboembolic diseases. They act either by inhibition of the clotting factor Xa or IIa (thrombin). As a consequence, they influence several coagulation assays (for example prothrombin time, activated partial thromboplastin time). Because of the short half-life of these new agents, these changes show great variations in the course of 24 hours. Furthermore, there are significant differences of laboratory results depending on the used reagents. We explain the influence of apixaban, rivaroxaban (factor Xa inhibitors) and dabigatran (thrombin inhibitor) on the most commonly used coagulation assays. Besides we show that this influence depends on the way of action of the drug as well as on the principle of the coagulation assay. Being aware of this relationships helps to interpret the results of coagulation assays under influence of NOACs correctly.

  15. Saliva-Induced Clotting Captures Streptococci: Novel Roles for Coagulation and Fibrinolysis in Host Defense and Immune Evasion.

    Science.gov (United States)

    Wollein Waldetoft, Kristofer; Mohanty, Tirthankar; Karlsson, Christofer; Mörgelin, Matthias; Frick, Inga-Maria; Malmström, Johan; Björck, Lars

    2016-10-01

    Streptococcal pharyngitis is among the most common bacterial infections, but the molecular mechanisms involved remain poorly understood. Here we investigate the interactions among three major players in streptococcal pharyngitis: streptococci, plasma, and saliva. We find that saliva activates the plasma coagulation system through both the extrinsic and the intrinsic pathways, entrapping the bacteria in fibrin clots. The bacteria escape the clots by activating host plasminogen. Our results identify a potential function for the intrinsic pathway of coagulation in host defense and a corresponding role for fibrinolysis in streptococcal immune evasion. PMID:27456827

  16. An investigation of the coagulant activity of the venom of the saw-scaled viper (Echis carinatus) from Saudi Arabia.

    Science.gov (United States)

    Kamiguti, A S; Theakston, R D; Tomy, S C

    1988-10-01

    Unlike the venom of Echis carinatus from India, Pakistan, Nigeria, Kenya, Iran and Oman, Saudi Arabian E. carinatus venom is a poor activator of prothrombin. However, it possesses similar defibrinogenating activity to the other venoms. This is because the venom from Saudi Arabian snakes contains a calcium-dependent factor X activator. It is suggested that in future studies of the coagulant activity of venoms, the determination of plasma coagulant activity should be carried out in the presence of added calcium ions. This applies particularly to those venoms which do not act on plasma or fibrinogen, but which do cause in vivo defibrinogenation. PMID:3257079

  17. Toward a better understanding of coagulation for dissolved organic nitrogen using polymeric zinc-iron-phosphate coagulant.

    Science.gov (United States)

    Zhu, Guocheng; Wang, Qian; Yin, Jun; Li, Zhongwu; Zhang, Peng; Ren, Bozhi; Fan, Gongduan; Wan, Peng

    2016-09-01

    The increase of agricultural related activities and the lack of effective waste control has led to an increase of organic nitrogen in water. The development of coagulants to effectively remove dissolved organic nitrogen (DON) is a high priority in the water treatment industry. We developed a polymeric zinc-iron-phosphate (ZnFeP) coagulant and investigated its coagulation effect on DON removal. Optimum coagulant for coagulation for DON and TDN removals was characterized by the dense convex-concave packing structure differing from other zinc-based coagulant, polycrystalline structure and high content colloidal species, which could account up to 87% of the total colloidal species. Coagulation experiments showed the DON removal rate to vary greatly depending on principal components and their interaction with metals, phosphate and hydroxyl. DON removal efficiency increased with the increase of colloidal species. The coagulation was also dependent on coagulant dosage and water quality parameters: Coagulation efficiency increased with coagulant dosage in the investigated range of 1-16 mg/l, and a pH of 6 was found to be superior for the coagulation. DON removal efficiency was also higher than and linearly correlated with total dissolved nitrogen (TDN) removal, which implies that an effective coagulation for TDN is also effective for DON. The findings in this study indicate that coagulation of DON is largely influenced by coagulant composition and species. We also found the removal of DON by our newly developed polymeric ZnFeP coagulant to be effective. PMID:27192355

  18. Diagnostics of Atmospheric Pressure Surface Discharge Plasmas in Argon

    Institute of Scientific and Technical Information of China (English)

    张锐; 詹如娟; 温晓辉

    2003-01-01

    Atmospheric pressure surface discharge is shown to have great prospects for a number of industrial applications.To acquire better results in application fields and considering that the study of the basic parameters including electron temperature and electron density is desirable,we develop an equivalent circuit model and the diagnostic techniques based on optical emission spectroscopy and electrical measurement in our laboratory.The electron temperature has been determined to be about 0.7eV by a Fermi-Dirac model.The electron density has been calculated to be near 1010 cm-3 from a time resolved electrical measurement(Ohmic heating method).

  19. Anatomy of an Inversion - Argon Isotopes

    Science.gov (United States)

    Zamick, L.; Sharon, Y. Y.; Robinson, S. J. Q.

    2012-02-01

    Two different interactions give similar results for excitation energies and g factors of 2+1 states for most even-even argon isotopes except 46Ar. This is explained in terms of an inversion in J = ½+ and levels in 47K which is successfully obtained by one of the interactions but not the other. This example shows the possible dangers of nuclear astrophysics extrapolations.

  20. Comparison of Al,Fe,Zr Performance on Coagulation

    OpenAIRE

    Prasobhan, Pratheesh

    2014-01-01

    This work addresses an investigation on and comparison of the coagulation performances of aluminium, iron and zirconium coagulants on real wastewater collected in Norway. This work was carried out from January 2014 to May 2014. Coagulation is an essential part of drinking water treatment as well as wastewater treatment. Aluminium and iron coagulants have been in use for many years as part of wastewater treatment. In recent years however, research has been focused on other new coagulants such...

  1. Effects of nucleotides and nucleosides on coagulation

    DEFF Research Database (Denmark)

    Bune, Laurids; Thaning, Pia; Johansson, Pär I;

    2010-01-01

    Nucleotides, including ADP, ATP and uridine triphosphate (UTP), are discharged profusely in the circulation during many pathological conditions including sepsis. Sepsis can cause hypotension and systemic activation of the coagulation and fibrinolytic systems in humans, which may cause disseminated...... intravascular coagulation. We investigated whether nucleotide-induced cardiovascular collapse as provoked by systemic infusion of adenosine, ADP, ATP, UTP and nitric oxide affected the haemostatic system as assessed by whole blood thromboelastography (TEG) analysis. Ten pigs received a randomized infusion...

  2. Fibrinolysis and the control of blood coagulation

    OpenAIRE

    Chapin, John C.; Hajjar, Katherine A.

    2014-01-01

    Fibrin plays an essential role in hemostasis as both the primary product of the coagulation cascade and the ultimate substrate for fibrinolysis. Fibrinolysis efficiency is greatly influenced by clot structure, fibrinogen isoforms and polymorphisms, the rate of thrombin generation, the reactivity of thrombus-associated cells such as platelets, and the overall biochemical environment. Regulation of the fibrinolytic system, like that of the coagulation cascade, is accomplished by a wide array of...

  3. Removal of silver nanoparticles by coagulation processes

    International Nuclear Information System (INIS)

    Highlights: • This study investigated the removal of AgNP suspensions by four regular coagulants. • The optimal removal efficiencies for the four coagulants were achieved at pH 7.5. • The removal efficiency of AgNPs was affected by the natural water characteristics. • TEM and XRD showed that AgNPs or silver-containing NPs were adsorbed onto the flocs. -- Abstract: Commercial use of silver nanoparticles (AgNPs) will lead to a potential route for human exposure via potable water. Coagulation followed by sedimentation, as a conventional technique in the drinking water treatment facilities, may become an important barrier to prevent human from AgNP exposures. This study investigated the removal of AgNP suspensions by four regular coagulants. In the aluminum sulfate and ferric chloride coagulation systems, the water parameters slightly affected the AgNP removal. However, in the poly aluminum chloride and polyferric sulfate coagulation systems, the optimal removal efficiencies were achieved at pH 7.5, while higher or lower of pH could reduce the AgNP removal. Besides, the increasing natural organic matter (NOM) would reduce the AgNP removal, while Ca2+ and suspended solids concentrations would also affect the AgNP removal. In addition, results from the transmission electron microscopy and X-ray diffraction showed AgNPs or silver-containing nanoparticles were adsorbed onto the flocs. Finally, natural water samples were used to validate AgNP removal by coagulation. This study suggests that in the case of release of AgNPs into the source water, the traditional water treatment process, coagulation/sedimentation, can remove AgNPs and minimize the silver ion concentration under the well-optimized conditions

  4. Modification of a commercial thromboelastography instrument to measure coagulation dynamics with three-dimensional biomaterials.

    Science.gov (United States)

    Hawker, Morgan J; Olver, Christine S; Fisher, Ellen R

    2016-06-01

    Three-dimensional synthetic constructs with complex geometries have immense potential for use in a multitude of blood-contacting applications. Understanding coagulation phenomena is arguably the most critical aspect for applications involving synthetic biomaterials; however, real-time evaluation of the clot formation while interfacing with these materials is difficult to achieve in a reproducible and robust manner. Here, work representing first steps toward addressing this deficit is presented, wherein modified consumables for a clinical instrument (a Thromboelastograph(®)) have been fabricated. Thromboelastography (TEG) measures viscoelastic properties throughout clot formation and therefore provides clinically relevant coagulation measurements in real time (i.e., kinetics and strength of clot formation). Through our modification, TEG consumables can readily accommodate three-dimensional materials (e.g., those for regenerative tissue applications). The authors performed proof-of-concept experiments using polymer scaffolds with a range of surface properties and demonstrated that variations in surface properties resulted in differences in blood plasma coagulation dynamics. For example, the maximum rate of thrombus generation ranged from 22.2 ± 2.2 (dyn/cm(2))/s for fluorocarbon coated scaffolds to 8.7 ± 1.0 (dyn/cm(2))/s for nitrogen-containing scaffolds. Through this work, the ability to make real-time coagulation activity measurements during constant coagulation factor interface with biomedically relevant materials is demonstrated. PMID:27126596

  5. [Incidental finding of pathological coagulation parameters].

    Science.gov (United States)

    Luxembourg, B; Lindhoff-Last, E

    2014-10-01

    Pathological coagulation parameters may reflect life-threatening hemorrhagic or thromboembolic diseases but may also be a laboratory result without any clinical significance, result from in vitro phenomena or preanalytical errors. This article gives an overview of potential pitfalls in coagulation diagnostics, lists the differential diagnoses of pathological coagulation parameters and describes further steps in the diagnostic approach to clarify pathological results. The focus lies on coagulation parameters that are frequently determined in routine clinical investigations, e.g. platelet count, prothrombin time, activated partial thromboplastin time (aPTT) and fibrinogen. Besides heparin, fondaparinux, danaparoid, and vitamin K antagonists, direct factor Xa inhibitors and direct thrombin inhibitors are nowadays available for therapeutic anticoagulation. This article gives an overview of the influence of anticoagulants on coagulation parameters which depends on the dose, the time of the last administration, as well as the method used for the determination of coagulation parameters. Moreover, common reasons for elevation of the fibrin degradation product D-dimer are presented. The clinical utility of D-dimer assays is limited by their poor specificity. Elevated D-dimer concentrations can be found in various diseases and also under normal physiological circumstances (e.g. in the elderly). Thus, the most useful clinical application of D-dimer is evidence of normal values to essentially rule out venous thromboembolism. PMID:25190093

  6. Development and experimental in-vivo evaluation of mathematical modeling of coagulation by laser

    Science.gov (United States)

    Beacco, Claire; Mordon, Serge R.; Brunetaud, Jean Marc

    1992-08-01

    Most clinical procedures using lasers are based on thermal laser-tissue interactions resulting in tissue damage. A mathematical model allowing temperature and damage prediction would be a useful tool to choose laser parameters able to produce the damage required. This study aimed at the development of a model called HELIOS. The capability of the model to predict thermal coagulation was evaluated by comparison with experimental in-vivo results. Conversion of laser light in tissue was studied using a beam broadening model, which is typically a modification of Beer-Lambert's law and takes into account scattering of light in tissue. HELIOS was validated making experimental studied in-vivo on liver (homogeneous tissue) of rats using a CW Nd:YAG laser, a CO2 laser, and an Argon laser. For a given set of laser parameters, temperature measurements were performed using an infrared camera (Agema, Sweden). The histological examination was carried out on samples to quantify the depth of coagulation necrosis. Experimental data obtained in-vivo were compared with those calculated previously using HELIOS and similar sets of parameters. The difference between the predicted temperature evolution on tissue surface and that measured by the infrared camera was less than 5 degree(s)C in all cases. The difference between the predicted coagulation necrosis depth and the corresponding experimental one was less than 10%. In conclusion, HELIOS allows good prediction of tissue temperature and coagulation necrosis. This model appears sufficiently precise for clinical applications and so should be well adapted to control thermal action of lasers in biological tissues.

  7. Modifying the properties of fluorinated amorphous films using argon by filtered cathodic vacuum arc

    Science.gov (United States)

    Lin, Yu-Hung; Syue, Yang-Chih; Lin, Hong-Da; Chen, Uei-Shin; Chang, Yee-Shyi; Chen, Jiann-Ruey; Shih, Han C.

    2008-12-01

    Fluorine-doped amorphous carbon (a-C:F) films were deposited using a 90°-bend magnetic filtered cathodic arc plasma system with CF 4 as a precursor and the addition of argon gas. The microstructure, composition and chemical bonding nature of the a-C:F films were investigated by Raman scattering spectroscopy and X-ray photoelectron spectroscopy. The surface morphology and roughness of a-C:F films were observed through an atomic force microscope. Hardness was measured by nano-indentation. Water contact angles were measured by the sessile drop method. The fluorine content of the films increases with the argon flux. Because of the increase of the fluorine content in the films, the film surface becomes rougher; the hardness decreases, and the contact angle increases from 76.2° to 87.8°. This work demonstrates that an appropriate amount of the admitted argon to the plasma would promote the doping of the films with fluorine, and influences the properties of the a-C:F films.

  8. Ovarian cancer, the coagulation pathway, and inflammation.

    Science.gov (United States)

    Wang, Xipeng; Wang, Ena; Kavanagh, John J; Freedman, Ralph S

    2005-06-21

    Epithelial ovarian cancer (EOC) represents the most frequent cause of death in the United States from a cancer involving the female genital tract. Contributing to the overall poor outcome in EOC patients, are the metastases to the peritoneum and stroma that are common in this cancer. In one study, cDNA microarray analysis was performed on fresh tissue to profile gene expression in patients with EOC. This study showed a number of genes with significantly altered expression in the pelvic peritoneum and stroma, and in the vicinity of EOC implants. These genes included those encoding coagulation factors and regulatory proteins in the coagulation cascade and genes encoding proteins associated with inflammatory responses. In addition to promoting the formation of blood clots, coagulation factors exhibit many other biologic functions as well as tumorigenic functions, the later including tumor cell proliferation, angiogenesis, invasion, and metastasis. Coagulation pathway proteins involved in tumorigenesis consist of factor II (thrombin), thrombin receptor (protease-activated receptors), factor III (tissue factor), factor VII, factor X and factor I (fibrinogen), and fibrin and factor XIII. In a recent study we conducted, we found that factor XII, factor XI, and several coagulation regulatory proteins, including heparin cofactor-II and epithelial protein C receptor (EPCR), were also upregulated in the peritoneum of EOC. In this review, we summarize evidence in support of a role for these factors in promoting tumor cell progression and the formation of ascites. We also discuss the different roles of coagulation factor pathways in the tumor and peritumoral microenvironments as they relate to angiogenesis, proliferation, invasion, and metastasis. Since inflammatory responses are another characteristic of the peritoneum in EOC, we also discuss the linkage between the coagulation cascade and the cytokines/chemokines involved in inflammation. Interleukin-8, which is considered an

  9. Ovarian cancer, the coagulation pathway, and inflammation

    Directory of Open Access Journals (Sweden)

    Kavanagh John J

    2005-06-01

    Full Text Available Abstract Epithelial ovarian cancer (EOC represents the most frequent cause of death in the United States from a cancer involving the female genital tract. Contributing to the overall poor outcome in EOC patients, are the metastases to the peritoneum and stroma that are common in this cancer. In one study, cDNA microarray analysis was performed on fresh tissue to profile gene expression in patients with EOC. This study showed a number of genes with significantly altered expression in the pelvic peritoneum and stroma, and in the vicinity of EOC implants. These genes included those encoding coagulation factors and regulatory proteins in the coagulation cascade and genes encoding proteins associated with inflammatory responses. In addition to promoting the formation of blood clots, coagulation factors exhibit many other biologic functions as well as tumorigenic functions, the later including tumor cell proliferation, angiogenesis, invasion, and metastasis. Coagulation pathway proteins involved in tumorigenesis consist of factor II (thrombin, thrombin receptor (protease-activated receptors, factor III (tissue factor, factor VII, factor X and factor I (fibrinogen, and fibrin and factor XIII. In a recent study we conducted, we found that factor XII, factor XI, and several coagulation regulatory proteins, including heparin cofactor-II and epithelial protein C receptor (EPCR, were also upregulated in the peritoneum of EOC. In this review, we summarize evidence in support of a role for these factors in promoting tumor cell progression and the formation of ascites. We also discuss the different roles of coagulation factor pathways in the tumor and peritumoral microenvironments as they relate to angiogenesis, proliferation, invasion, and metastasis. . Since inflammatory responses are another characteristic of the peritoneum in EOC, we also discuss the linkage between the coagulation cascade and the cytokines/chemokines involved in inflammation. Interleukin

  10. Effect of Crocus sativus L. (saffron) on coagulation and anticoagulation systems in healthy volunteers.

    Science.gov (United States)

    Ayatollahi, Hossein; Javan, Atefeh Ordoei; Khajedaluee, Mohammad; Shahroodian, Masood; Hosseinzadeh, Hossein

    2014-04-01

    Saffron showed some effects on blood coagulation and platelet aggregation in in vitro and in vivo studies. In a clinical trial with a limited number volunteers, saffron tablets influenced on bleeding time. In this study, the effect of saffron on plasma level of fibrinogen, factor VII (as coagulant agent), C and S protein (as anti-coagulant agent), PT and PTT in a larger sample size was evaluated. The study was a double-blind, placebo-controlled study consisting of 1 week treatment with 200 mg and 400 mg saffron tablets. Sixty healthy volunteers (age range 20-50 years) were selected for the study. The volunteers were divided into three groups of 20 each. Group 1 received placebo; Groups 2 and 3 received 200 mg and 400 mg saffron tablets, respectively, for 7 days (1 tablet per day). Before and after 7 days treatment and also 1 month after that, blood samples were taken. The plasma levels of fibrinogen, factor VII, C and S protein, PT and PTT were evaluated. Statistical analysis showed no difference between groups for any of evaluated factors. This study rejected any effect of saffron with dose of 200 and 400 mg for 1 week on coagulant and anticoagulant system.

  11. 内镜下氩离子凝固术治疗结直肠息肉92例护理体会%Experience of nursing care in the treatment of 92 patients with colorectal polyp by using argon ion plasma coagulation under endoscope

    Institute of Scientific and Technical Information of China (English)

    郭荣; 王明英; 吕燕; 曹允芳

    2007-01-01

    目的:探讨内镜下氩离子凝固术(APC)治疗结、直肠息肉的护理方法.方法:对92例结、直肠息肉患者采用内镜下APC联合高频电切术进行治疗.结果:本组56例息肉直径<4mm者,采用APC 1次性治疗消除;36例息肉直径>4mm者,根据不同形态及有无蒂采用粘膜下注射生理盐水、高频电切除术,对残端有渗血或息肉残留者再用APC处理,效果满意,且无不良反应.结论:APC治疗结、直息肉患者痛苦小,值得推广应用.

  12. EVALUATION OF INDUSTRIAL DYEING WASTEWATER TREATMENT WITH COAGULANTS AND POLYELECTROLYTE AS A COAGULANT AID

    Directory of Open Access Journals (Sweden)

    G. R. Nabi Bidhendi;A. Torabian;H. Ehsani;N. Razmkhah

    2007-01-01

    Full Text Available Textile industry is the major source of water consumption and wastewater pollution. There are various treatment techniques to remove textile wastewater pollution. Coagulation-flocculation is a widely used process to remove pollution due to suspended particles. In this research, different coagulants like Alum, Lime, FeCl3, FeSO4 and MgCl2 were applied to select the suitable ones with optimum removal efficiency. Settling characteristics of flocs formed in the coagulation process were studied in a laboratory scale settling column unit. Parameters such as color, COD, TSS, turbidity and settled sludge volume have been evaluated. The optimum coagulant dose and pH value were determined by comparing the effectiveness of these coagulants. Results showed other coagulants except lime could eliminate color and COD successfully. In this case, FeSO4 was chosen as an optimum coagulant for color removal because of the lowest required coagulant dose, minimum settled sludge volume and maximum decolorization.

  13. EDITORIAL: Focus on Plasma Medicine

    Science.gov (United States)

    Morfill, G. E.; Kong, M. G.; Zimmermann, J. L.

    2009-11-01

    -pressure microwave plasmas in an N2 and O2 gas mixture M K Singh, A Ogino and M Nagatsu Degradation of adhesion molecules of G361 melanoma cells by a non-thermal atmospheric pressure microplasma H J Lee, C H Shon, Y S Kim, S Kim, G C Kim and M G Kong The acidification of lipid film surfaces by non-thermal DBD at atmospheric pressure in air A Helmke, D Hoffmeister, N Mertens, S Emmert, J Schuette and W Vioel Reduction and degradation of amyloid aggregates by a pulsed radio-frequency cold atmospheric plasma jet D L Bayliss, J L Walsh, G Shama, F Iza and M G Kong The effect of low-temperature plasma on bacteria as observed by repeated AFM imaging René Pompl, Ferdinand Jamitzky, Tetsuji Shimizu, Bernd Steffes, Wolfram Bunk, Hans-Ulrich Schmidt, Matthias Georgi, Katrin Ramrath, Wilhelm Stolz, Robert W Stark, Takuya Urayama, Shuitsu Fujii and Gregor Eugen Morfill Removal and sterilization of biofilms and planktonic bacteria by microwave-induced argon plasma at atmospheric pressure Mi Hee Lee, Bong Joo Park, Soo Chang Jin, Dohyun Kim, Inho Han, Jungsung Kim, Soon O Hyun, Kie-Hyung Chung and Jong-Chul Park Cell permeabilization using a non-thermal plasma M Leduc, D Guay, R L Leask and S Coulombe Physical and biological mechanisms of direct plasma interaction with living tissue Danil Dobrynin, Gregory Fridman, Gary Friedman and Alexander Fridman Nosocomial infections-a new approach towards preventive medicine using plasmas G E Morfill, T Shimizu, B Steffes and H-U Schmidt Generation and transport mechanisms of chemical species by a post-discharge flow for inactivation of bacteria Takehiko Sato, Shiroh Ochiai and Takuya Urayama Low pressure plasma discharges for the sterilization and decontamination of surfaces F Rossi, O Kylián, H Rauscher, M Hasiwa and D Gilliland Contribution of a portable air plasma torch to rapid blood coagulation as a method of preventing bleeding S P Kuo, O Tarasenko, J Chang, S Popovic, C Y Chen, H W Fan, A Scott, M Lahiani, P Alusta, J D Drake and M Nikolic A two

  14. Are the argon metastables important in high power impulse magnetron sputtering discharges?

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J. T., E-mail: tumi@hi.is [Department of Space and Plasma Physics, School of Electrical Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavik (Iceland); Lundin, D.; Minea, T. M. [Laboratoire de Physique des Gaz et Plasmas - LPGP, UMR 8578 CNRS, Université Paris-Sud, 91405 Orsay Cedex (France); Stancu, G. D. [CentraleSupélec, Grande Voie des Vignes, 92295 Chatenay-Malabry Cedex (France); CNRS, UPR 288 Laboratoire EM2C, Grande Voie des Vignes, 92295 Chatenay-Malabry Cedex (France); Brenning, N. [Department of Space and Plasma Physics, School of Electrical Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Plasma and Coatings Physics Division, IFM-Materials Physics, Linköping University, SE-581 83 Linköping (Sweden)

    2015-11-15

    We use an ionization region model to explore the ionization processes in the high power impulse magnetron sputtering (HiPIMS) discharge in argon with a titanium target. In conventional dc magnetron sputtering (dcMS), stepwise ionization can be an important route for ionization of the argon gas. However, in the HiPIMS discharge stepwise ionization is found to be negligible during the breakdown phase of the HiPIMS pulse and becomes significant (but never dominating) only later in the pulse. For the sputtered species, Penning ionization can be a significant ionization mechanism in the dcMS discharges, while in the HiPIMS discharge Penning ionization is always negligible as compared to electron impact ionization. The main reasons for these differences are a higher plasma density in the HiPIMS discharge, and a higher electron temperature. Furthermore, we explore the ionization fraction and the ionized flux fraction of the sputtered vapor and compare with recent experimental work.

  15. 产后出血患者大量输血治疗时血浆和红细胞的比例对凝血功能的影响%Effect of ratio of fresh frozen plasma to red blood cells on coagulation function in patients with massive blood transfusion for postpartum hemorrhage

    Institute of Scientific and Technical Information of China (English)

    刘桂芳; 金勇; 夏和凤

    2016-01-01

    目的 探讨产后大出血患者早期大量输血时,输入新鲜冰冻血浆(FFP)和红细胞(RBC)的比例对凝血功能的影响.方法 因产后大出血24 h内需输注RBC大于10 U的患者45例,按输注FFP与悬浮RBC的比例,随机分为低血浆组(A组,FFP∶ RC=1∶2.5,15例)、中血浆组(B组,FFP∶ RBC=1∶1,16例)和高血浆组(C组,FFP∶ RBC=1.5∶1,14例).检测产前和输血后24h凝血功能和血常规,比较三组患者大量输血后24h内RBC和冷沉淀输入量的差异.结果 三组患者产前凝血功能、血常规比较无统计学差异(P>0.05).大量输血24 h后,A组凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)延长,纤维蛋白原(Fbg)含量降低(P<0.05),B、C组凝血功能无明显变化(P>0.05);三组患者大量输血后血小板计数(Plt)及血红蛋白(Hb)均降低(P<0.05),B组优于A、C组(P<0.05).三组间24 h内输注RBC和冷沉淀的量无统计学差异(P>0.05).结论 产后大出血患者输血时,FFP与RBC比例过低,可造成血液稀释性低凝,建议以1∶1比例输注为宜.%Objective To investigate the effect of ratio of fresh frozen plasma(FFP) to red blood cells (RBC) on coagulation function in the patients with massive blood transfusion for postpartum hemorrhage.Methods Forty-five patients with blood transfusion more than 10 U in 24 hours were randomly assigned into three groups of A(ratio of FFP to RBC 1 ∶ 2.5,15 cases),B(ratio of FFP to RBC 1 ∶ 1,16 cases) and C(ratio of FFP to RBC 1.5 ∶ 1,14 cases).The coagulation function was examined before delivery and at 24 hours after transfusion.The volumes of RBC and cryoprecipitate infused in 24 hours were compared among three groups.Results The tests of coagulation function,platelet and hemoglobin (Hb) of three groups were similar before delivery (P>0.05).The prothrombin time (PT) and activated partial thromboplastin time (APTT) were significantly prolonged and fibrinogen was decreased at 24 hours after

  16. Effects of Nitrogen contamination in liquid Argon

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Baibussinov, B.; Baldo-Ceolin, M.; Benetti, P.; Calaprice, F.; Calligarich, E.; Cambiaghi, M.; Canci, N.; Carbonara, F.; Cavanna, F.; Centro, S.; Cocco, A. G.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Gallo, V.; Grandi, L.; Meng, G.; Modena, I.; Montanari, C.; Palamara, O.; Pandola, L.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Roncadelli, M.; Rossella, M.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Ventura, S.; Vignoli, C.

    2010-06-01

    A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. The purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from ~ 10-1 ppm up to ~ 103 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (γ-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. Direct PMT signal acquisition exploiting high time resolution by fast waveform recording allowed high precision extraction of the main characteristics of the scintillation light emission in contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable starting from Script O(1 ppm) of Nitrogen concentrations. The rate constant of the quenching process induced by Nitrogen in liquid Ar has been found to be kQ(N2) = 0.11 ± 0.01 μs-1ppm-1, consistent with a previous measurement of this quantity but with significant improvement in precision. On the other hand, no evidence for absorption by N2 impurities has been found up to the higher concentrations here explored.

  17. Diagnosis and treatment of disseminated intravascular coagulation.

    Science.gov (United States)

    Levi, M

    2014-06-01

    Disseminated intravascular coagulation (DIC) is a condition in which systemic activation of coagulation without a specific localization occurs, resulting in extensive formation of intravascular fibrin, particularly in small and midsize vessels. Disseminated intravascular coagulation may lead to several altered coagulation parameters, including a low platelet count, abnormal global clotting assays, low levels of physiological anticoagulant proteases, or increased fibrin degradation products. Also, more complex assays for activation of coagulation factors or pathways may indicate involvement of these molecules in DIC. None of these tests alone, however, can accurately ascertain or rebuff a diagnosis of DIC. Nonetheless, a combination of readily available routine assays may be instrumental in establishing a diagnosis of DIC and can also be useful to point to a subset of patients with DIC that may need definite, often costly, interventions in the hemostatic system. Current insights on relevant etiological pathways that may contribute to the occurrence of DIC have led to innovative therapeutic and adjunctive approaches to patient with DIC. Management options directed at the amelioration of hemostatic activation may tentatively be indicated and were found to be advantageous in experimental and clinical investigations. These treatments encompass elimination of tissue factor-mediated thrombin generation or restitution of normal anticoagulant function.

  18. Argon diffusion from biotite at high temperature and pressure

    Institute of Scientific and Technical Information of China (English)

    陈道公; 贾命命; 李彬贤; 陆全明; 谢鸿森; 侯渭

    1995-01-01

    t The experiments of argon diffusion dynamics for biotite were carried out at 700 -1000℃ and 0.5 - 2,0 GPa and the diffusion coefficient and activation energy using different models have been calculated. The results indicate that the pressure does affect the argon diffusion and its effect is opposite to that of temperature. When p increases, the activation energy increases and diffusion coefficient decreases. The relation between pressure, closure temperature and cooling rate has been obtained. It is postulated that in low T and high p conditions, the argon diffusion from the environment to the system could occur and incur the appearance of the external argon in minerals.

  19. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  20. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  1. Argon isotope fractionation induced by stepwise heating

    Science.gov (United States)

    Trieloff, Mario; Falter, Martina; Buikin, Alexei I.; Korochantseva, Ekaterina V.; Jessberger, Elmar K.; Altherr, Rainer

    2005-03-01

    Noble gas isotopes are widely used to elucidate the history of the rocks in which they have been trapped, either from distinct reservoirs or by accumulation following radioactive decay. To extract noble gases from their host rocks, stepwise heating is the most commonly used technique to deconvolve isotopically different components, e.g., atmospheric, in situ radiogenic, or excess radiogenic from mantle or crustal reservoirs. The accurate determination of the isotopic composition of these different components is of crucial importance, e.g., for ages obtained by 40Ar- 39Ar stepheating plateaus. However, diffusion theory-based model calculations predict that the stepwise thermal extraction process from mineral phases induces isotope fractionation and, hence, adulterates the original composition. Such effects are largely unconsidered, as they are small and a compelling experimental observation is lacking. We report the first unequivocal evidence for significant mass fractionation of argon isotopes during thermal extraction, observed on shungite, a carbon-rich Precambrian sedimentary rock. The degree of fractionation, as monitored by 38Ar/ 36Ar and 40Ar/ 36Ar ratios, very well agrees with theoretical predictions assuming an inverse square root dependence of diffusion coefficient and atomic mass, resulting in easier extraction of lighter isotopes. Hence, subatmospheric 40Ar/ 36Ar ratios obtained for argon extracted at low temperatures may not represent paleoatmospheric argon. Shungite argon resembles modern atmospheric composition, but constraints on the timing of trapping appear difficult to obtain, as shungites are multicomponent systems. In 40Ar- 39Ar stepwise heating, the isotope fractionation effect could cause systematic underestimations of plateau ages, between 0.15 and 0.4% depending on age, or considerably higher if samples contain appreciable atmospheric Ar. The magnitude of this effect is similar to the presently achieved uncertainties of this increasingly

  2. Argon Purification Studies and a Novel Liquid Argon Re-circulation System

    CERN Document Server

    Mavrokoridis, K; Coleman, J; Lightfoot, P K; McCauley, N; McCormick, K J; Touramanis, C

    2011-01-01

    Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapou...

  3. Activation of Coagulation by Administration of Recombinant Factor VIIa Elicits Interleukin 6 (IL-6) and IL-8 Release in Healthy Human Subjects

    OpenAIRE

    de Jonge, Evert; Friederich, Philip W.; Vlasuk, George P.; Rote, William E.; Vroom, Margaretha B.; Levi, Marcel; van der Poll, Tom

    2003-01-01

    The activation of coagulation has been shown to contribute to proinflammatory responses in animal and in vitro experiments. Here we report that the activation of coagulation in healthy human subjects by the administration of recombinant factor VIIa also elicits a small but significant increase in the concentrations of interleukin 6 (IL-6) and IL-8 in plasma. This increase was absent when the subjects were pretreated with recombinant nematode anticoagulant protein c2, the inhibitor of tissue f...

  4. Monitoring Thermal Coagulation with Ultrasonic Textures

    Institute of Scientific and Technical Information of China (English)

    YANG Wei; ZHANG Su; CHEN Ya-zhu; CHEN Lei; HU Bing; MA Wei-yin

    2007-01-01

    The feasibility of using B-mode ultrasound image textures and pattern recognition technique to characterize the thermal coagulation in vitro during radiofrequency ablation was investigated.The changes of ultrasonic textures in the different regions of samples varied with the heating time in the in-vitro experiments, which would result in that the coagulated and noncoagulated regions of tissue had different ultrasonic textures.Using support vector machine to extract the ultrasonic texture features and characterize the state of tissue, the size and boundaries of thermal lesions could be detected and measured more exactly than only using the gray scale information of B-mode ultrasound image.The proposed method would be applied to the image-guided radiofrequency ablation (IGRA) procedure for monitoring the thermal coagulation.

  5. Coagulation function in patients with pancreatic carcinoma

    Institute of Scientific and Technical Information of China (English)

    WANG Hang-yan; XIU Dian-rong; LI Zhi-fei; WANG Gang

    2009-01-01

    Background The coagulation function in patients with pancreatic carcinoma is abnormal and the reason is not very clear. In this study, we retrospectively analyzed the coagulation function in patients with pancreatic carcinoma.Methods From June 2004 to December 2007, 132 patients received diagnosis and treatment in our hospital. The coagulative parameters including the prothrombin time, activated partial thromboplastin time, and fibrinogen levels were collected and studied retrospectively.Results The average fibrinogen levels in patients with pancreatic carcinoma, (476.21±142.05) mg/dl, were significantly higher than in patients with cholangiolithiasis, (403.28±126.41) mg/dl (P 0.05).Conclusions The level of fibrinogen in patients with pancreatic carcinoma was elevated. The elevated fibrinogen level may be associated with invasiveness and lymphatic metastasis. Using vitamin K in perioperation management did not reduce intraoperative blood loss.

  6. Comparison study of metastasis hepatic coagulation

    International Nuclear Information System (INIS)

    In our contribution we are interested in tissue coagulation by Nd-YAG and Ar lasers in order to know which laser is necessary to use for the destruction of hepatic metastasis. For that we have developed a mathematical model, in which the liver tissue is considered homogeneous, and isotropic, the absorbed energies is optimized by the beam broadening model and the transfer of heat is modeled by the bioheat equation. The solution of this equation by the finite volumes method gives the space-time variation of the temperature, which makes it possible to determine the necrosis depth by using the Arrhenius integral. The results obtained show that the temperature of coagulation is reached for strong intensity in the case of the Nd-YAG laser compared with the Ar laser, and that the volume of the coagulated zone is considerable in the case of the Nd-YAG laser, from this fact it is selected in gastro-enterology. (author)

  7. Post-treatment of sanitary landfill leachate by coagulation-flocculation using chitosan as primary coagulant.

    Science.gov (United States)

    Nascimento, Inara Oliveira do Carmo; Guedes, Ana Rosa Pinto; Perelo, Louisa Wessels; Queiroz, Luciano Matos

    2016-01-01

    Chitosan was chosen as an alternative primary coagulant in a complementary coagulation-flocculation treatment of sanitary landfill leachate with the aim of removing recalcitrant organic matter. In order to optimize the process conditions, central composite design and response surface methodology were applied. To evaluate the performance of the process using chitosan, we also carried out tests with aluminium sulphate (Al(2) (SO(4))(3).14 H(2)O) as coagulant. In addition, acute toxicity tests were carried using the duckweed Lemna minor and the guppy fish Poecilia reticulata as test organisms. The analytic hierarchy process was employed for selecting the most appropriate coagulant. Mean values of true colour removal efficiency of 80% and turbidity removal efficiency of 91.4% were reached at chitosan dosages of 960 mg L(-1) at pH 8.5. The acute toxicity tests showed that organisms were sensitive to all samples, mainly after coagulation-flocculation using chitosan. CE(50) for L. minor was not determined because there was no inhibition of the average growth rate and biomass production; LC(50) for P. reticulata was 23% (v v(-1)). Multi-criteria analysis showed that alum was the most appropriate coagulant. Therefore, chitosan as primary coagulant was not considered to be a viable alternative in the post-treatment of landfill leachate. PMID:27387003

  8. Application of psyllium husk as coagulant and coagulant aid in semi-aerobic landfill leachate treatment.

    Science.gov (United States)

    Al-Hamadani, Yasir A J; Yusoff, Mohd Suffian; Umar, Muhammad; Bashir, Mohammed J K; Adlan, Mohd Nordin

    2011-06-15

    Landfill leachate is a heavily polluted and a likely hazardous liquid that is produced as a result of water infiltration through solid wastes generated industrially and domestically. This study investigates the potential of using psyllium husk as coagulant and coagulant aid for the treatment of landfill leachate. Psyllium husk has been tested as primary coagulant and as coagulant aid with poly-aluminum chloride (PACl) and aluminum sulfate (alum). As primary coagulant, the optimum dosage and pH for PACl were 7.2 and 7.5 g/L, respectively, with removal efficiencies of 55, 80 and 95% for COD, color and TSS, respectively. For alum, the optimum conditions were 11 g/L alum dosage and pH 6.5 with removal efficiencies of 58, 79 and 78% for COD, color and TSS, respectively. The maximum removal efficiencies of COD, color and TSS were 64, 90 and 96%, respectively, when psyllium husk was used as coagulant aid with PACl. Based on the results, psyllium husk was found to be more effective as coagulant aid with PACl in the removal of COD, color and TSS as compared to alum. Zeta potential test was carried out for leachate, PACl, alum and psyllium husk before and after running the jar test to enhance the results of the jar test experiments. PMID:21507572

  9. Coagulation factor deficiency apparently related to the Fitzgerald trait: the first cases in Japan.

    Directory of Open Access Journals (Sweden)

    Hayashi,Hisamoto

    1978-04-01

    Full Text Available A blood coagulation deficiency was found at the contact phase in identical Japanese female twins. Of the four possible factors involved, Factor XI or XII can be ruled out according to cross-correction studies. The problem factor was probably not Fletcher factor, because the abnormal partial thromboplastin time was not significantly shortened by increasing the incubation period of plasma with kaolin. The deficiency is most likely due to the lack of Fitzgerald factor.

  10. Coagulant and anticoagulant activities in Jatropha curcas latex.

    Science.gov (United States)

    Osoniyi, Omolaja; Onajobi, Funmi

    2003-11-01

    Jatropha curcas Linn. (Euphorbiaceae), a medicinal plant commonly grown in the Tropics, is traditionally used as a haemostatic. Investigation of the coagulant activity of the latex of Jatropha curcas showed that whole latex significantly (Platex, however, prolonged the clotting time: at high dilutions, the blood did not clot at all. This indicates that Jatropha curcas latex possesses both procoagulant and anticoagulant activities. Prothrombin time (PT) and activated partial thromboplastin time (APTT) tests on plasma confirm these observations. Solvent partitioning of the latex with ethyl acetate and butanol led to a partial separation of the two opposing activities: at low concentrations, the ethyl acetate fraction exhibited a procoagulant activity, while the butanol fraction had the highest anticoagulant activity. The residual aqueous fraction had no significant effect on the clotting time of blood and the PT but slightly prolonged the APTT.

  11. Disseminated intravascular coagulation in burn injury.

    Science.gov (United States)

    Lippi, Giuseppe; Ippolito, Luigi; Cervellin, Gianfranco

    2010-06-01

    Disseminated intravascular coagulation (DIC) is a complex and multifaceted disorder characterized by the activation of coagulation and fibrinolytic pathways, consumption of coagulation factors, and depletion of coagulation regulatory proteins. The introduction into the circulation of cellular debris characterized by strong thromboplastic activity due to tissue factor exposition or release (in or from burned tissues), which can thereby activate extrinsic pathway of coagulation system and trigger massive thrombin generation when present in sufficient concentration, represents the most plausible biological explanation to support the development of intravascular coagulation in patients with burn injury. Severe burns left untreated might also lead to an immunological and inflammatory response (activation of the complement cascade), which can amplify fibrinolysis and blood clotting. Overall, the real prevalence of DIC in patients with burns is as yet unclear. Postmortem, retrospective, and even longitudinal investigations are in fact biased by several factors, such as the objective difficulty to establish whether DIC might have occurred as a primary complication of burns or rather as a consequence of other superimposed pathologies (e.g., sepsis, multiple organ failure), the different diagnostic criteria for assessing DIC, and the heterogeneity of the patient samples studied. Nevertheless, the current scientific evidence is consistent with the hypothesis that biochemical changes suggestive for DIC (hypercoagulability, hypo- and hyperfibrinolysis) are commonplace in patients with burn trauma, and their severity increases exponentially with the severity of injury. Overt DIC seems to occur especially in critically ill burn patients or in those with severe burns (up to third degree) and large involvement of body surface area, in whom an appropriate therapy might be effective to prevent the otherwise fulminant course. Although early prophylaxis with antithrombin concentrates

  12. Ion-beam excitation of liquid argon

    CERN Document Server

    Hofmann, M; Heindl, T; Neumeier, A; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Wieser, J; Ulrich, A

    2015-01-01

    The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using ou...

  13. Argon laser-welded arteriovenous anastomoses.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; White, G; Lyons, R; Fujitani, R; Klein, S R; Uitto, J

    1987-11-01

    This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line. PMID:3312648

  14. Electron scattering and transport in liquid argon

    International Nuclear Information System (INIS)

    The transport of excess electrons in liquid argon driven out of equilibrium by an applied electric field is revisited using a multi-term solution of Boltzmann’s equation together with ab initio liquid phase cross-sections calculated using the Dirac-Fock scattering equations. The calculation of liquid phase cross-sections extends previous treatments to consider multipole polarisabilities and a non-local treatment of exchange, while the accuracy of the electron-argon potential is validated through comparison of the calculated gas phase cross-sections with experiment. The results presented highlight the inadequacy of local treatments of exchange that are commonly used in liquid and cluster phase cross-section calculations. The multi-term Boltzmann equation framework accounting for coherent scattering enables the inclusion of the full anisotropy in the differential cross-section arising from the interaction and the structure factor, without an a priori assumption of quasi-isotropy in the velocity distribution function. The model, which contains no free parameters and accounts for both coherent scattering and liquid phase screening effects, was found to reproduce well the experimental drift velocities and characteristic energies

  15. Pollution of liquid argon after neutron irradiation

    CERN Document Server

    Andrieux, M L; Collot, J; de Saintignon, P; Ferrari, A; Hostachy, J Y; Hoummada, A; Martin, P; Merkel, B; Puzo, P; Sauvage, D; Wielers, M

    2001-01-01

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem. (17 refs).

  16. Pollution of liquid argon after neutron irradiation

    International Nuclear Information System (INIS)

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem

  17. Quantifying interspecific coagulation efficiency of phytoplankton

    DEFF Research Database (Denmark)

    Hansen, J.L.S.; Kiørboe, Thomas

    1997-01-01

    the interspecific coagulation efficiency could be calculated. Stickiness between beads and T. nordenskjoeldii was 50% of that of T. nordenskjoeldii in monospecific suspensions, and this ratio remained constant throughout 12 experiments covering 1 order of magnitude variation in the stickiness level of T....... nordenskjoeldii. Mutual coagulation between Skeletonema costatum and the non-sticky cel:ls of Ditylum brightwellii also proceeded with hall the efficiency of S. costatum alone. The latex beads were suitable to be used as 'standard particles' to quantify the ability of phytoplankton to prime aggregation...

  18. Plasma metallization

    CERN Document Server

    Crowther, J M

    1997-01-01

    Many methods are currently used for the production of thin metal films. However, all of these have drawbacks associated with them, for example the need for UHV conditions, high temperatures, exotic metal precursors, or the inability to coat complex shaped objects. Reduction of supported metal salts by non-isothermal plasma treatment does not suffer from these drawbacks. In order to produce and analyse metal films before they become contaminated, a plasma chamber which could be attached directly to a UHV chamber with XPS capability was designed and built. This allowed plasma treatment of supported metal salts and surface analysis by XPS to be performed without exposure of the metal film to the atmosphere. Non-equilibrium plasma treatment of Nylon 66 supported gold(lll) chloride using hydrogen as the feed gas resulted in a 95% pure gold film, the remaining 5% of the film being carbon. If argon or helium were used as the feed gases during plasma treatment the resultant gold films were 100% pure. Some degree of s...

  19. Coagulant recovery and reuse for drinking water treatment

    OpenAIRE

    Keeley, James; Jarvis, Peter; Smith, Andrea D.; Judd, Simon J.

    2015-01-01

    Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgi...

  20. The Interface between Inflammation and Coagulation in Cardiovascular Disease

    OpenAIRE

    Gabriele Demetz; Ilka Ott

    2012-01-01

    The intimate connection between coagulation and inflammation in the pathogenesis of vascular disease has moved more and more into focus of clinical research. This paper focuses on the essential components of this interplay in the settings of cardiovascular disease and acute coronary syndrome. Tissue factor, the main initiator of the extrinsic coagulation pathway, plays a central role via causing a proinflammatory response through activation of coagulation factors and thereby initiating coagul...

  1. Mathematical Model of Extrinsic Blood Coagulation Cascade Dynamic System

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The blood coagulation system is very important to life. This paper presents a mathematical blood coagulation model for the extrinsic pathway. This model simulates clotting factor VIII, which plays an important role in the coagulation mechanism. The mathematical model is used to study the equilibrium stability, orbit structure, attractors and global stability behavior, with conclusions in accordance with the physiological phenomena. Moreover, the results provide information about blood related illnesses, which can be used for further study of the coagulation mechanism.

  2. Blood Coagulation Induced by Iranian Saw-Scaled Viper (Echis Carinatus) Venom: Identification, Purification and Characterization of a Prothrombin Activator

    OpenAIRE

    Mahdi Babaie; Hossein Salmanizadeh; Hossein Zolfagharian

    2013-01-01

      Objective(s): Echis carinatus is one of the venomous snakes in Iran. The venom of Iranian Echis carinatus is a rich source of protein with various factors affecting the plasma protein and blood coagulation factor. Some of these proteins exhibit types of enzymatic activities. However, other items are proteins with no enzymatic activity.   Materials and Methods: In order to study the mechanism and effect of the venom on human plasma proteins, the present study has evaluated the effect of crud...

  3. EDITORIAL: Focus on Plasma Medicine

    Science.gov (United States)

    Morfill, G. E.; Kong, M. G.; Zimmermann, J. L.

    2009-11-01

    -pressure microwave plasmas in an N2 and O2 gas mixture M K Singh, A Ogino and M Nagatsu Degradation of adhesion molecules of G361 melanoma cells by a non-thermal atmospheric pressure microplasma H J Lee, C H Shon, Y S Kim, S Kim, G C Kim and M G Kong The acidification of lipid film surfaces by non-thermal DBD at atmospheric pressure in air A Helmke, D Hoffmeister, N Mertens, S Emmert, J Schuette and W Vioel Reduction and degradation of amyloid aggregates by a pulsed radio-frequency cold atmospheric plasma jet D L Bayliss, J L Walsh, G Shama, F Iza and M G Kong The effect of low-temperature plasma on bacteria as observed by repeated AFM imaging René Pompl, Ferdinand Jamitzky, Tetsuji Shimizu, Bernd Steffes, Wolfram Bunk, Hans-Ulrich Schmidt, Matthias Georgi, Katrin Ramrath, Wilhelm Stolz, Robert W Stark, Takuya Urayama, Shuitsu Fujii and Gregor Eugen Morfill Removal and sterilization of biofilms and planktonic bacteria by microwave-induced argon plasma at atmospheric pressure Mi Hee Lee, Bong Joo Park, Soo Chang Jin, Dohyun Kim, Inho Han, Jungsung Kim, Soon O Hyun, Kie-Hyung Chung and Jong-Chul Park Cell permeabilization using a non-thermal plasma M Leduc, D Guay, R L Leask and S Coulombe Physical and biological mechanisms of direct plasma interaction with living tissue Danil Dobrynin, Gregory Fridman, Gary Friedman and Alexander Fridman Nosocomial infections-a new approach towards preventive medicine using plasmas G E Morfill, T Shimizu, B Steffes and H-U Schmidt Generation and transport mechanisms of chemical species by a post-discharge flow for inactivation of bacteria Takehiko Sato, Shiroh Ochiai and Takuya Urayama Low pressure plasma discharges for the sterilization and decontamination of surfaces F Rossi, O Kylián, H Rauscher, M Hasiwa and D Gilliland Contribution of a portable air plasma torch to rapid blood coagulation as a method of preventing bleeding S P Kuo, O Tarasenko, J Chang, S Popovic, C Y Chen, H W Fan, A Scott, M Lahiani, P Alusta, J D Drake and M Nikolic A two

  4. WARP: a double phase argon programme for dark matter detection

    International Nuclear Information System (INIS)

    WARP (Wimp ARgon Programme) is a double phase Argon detector for Dark Matter search under construction at Laboratori Nazionali del Gran Sasso. We present recent results obtained operating a prototype with a sensitive mass of 2.3 litres deep underground

  5. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.;

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...

  6. Comparison of Diode and Argon Laser Lesions in Rabbit Retina

    Institute of Scientific and Technical Information of China (English)

    Hui Zhang; Xiaoxin Li; Bin Li; Jiping Da

    2004-01-01

    Purpose: To compare the histological alteration of retina with various spot intensities between diode and argon lasers in order to instruct the clinical use of 810 nm diode laser.Methods: Transpupillary retinal photocoagulations were performed on 42 eyes of 27pigmented rabbits. Histopathologic alteration of lesions in different intensities and different time intervals after irradiation produced by diode and argon laser was observed and compared using light microscopy. Areas of various lesions measured by image analysis system (CMIAS) were compared quantitatively.Results: Histopathologically, two-week-old grade 2 lesions produced by diode laser induced the disappearance of outer nuclear cells. More than a half of all showed reduction in number of outer nuclear layer cells in argon. Fibroblasts appeared in the diode grade 3lesions 5 days after irradiation. CMIAS data showed that all the areas of diode lesions immediately after photocoagulation were to be larger than those of argon laser lesions in the same spot intensity (P < 0.05). However, twenty-four hours after photocoagulation, the area of the diode lesions increased less than that of the argon laser lesions (8%vs.23%).Conclusion: The acute histological effect caused by 810 nm diode laser and argon green laser is similar,while the expansion of lesion area 24 hours after photocoagulation was less with the diode laser compared to the argon. This may be the first report in the literature regarding quantitative analysis of the delayed reaction of argon green lasers.

  7. A Power Interruption Technique for Investigation of Temperature Difference in Stabilized Low Direct-Current Arc Burning in Pure Argon on Atmospheric Pressure

    Institute of Scientific and Technical Information of China (English)

    M. M. Kuzmanovi(c); J. J. Savovi(c); D. P. Rankovi(c); M. Stoiljkovi(c); A. Anti(c)-Jovanovi(c); M.S. Pavlovi(c); M. Marinkovi(c)

    2008-01-01

    @@ Plasma of argon stabilized arc column, in a current range 3-11 A, is investigated using emission spectrometric diagnostic techniques. Temperatures are evaluated using several methods: argon line to adjacent recombinational continuum intensity ratio, absolute emissivity of argon fine, measurement of electron number density, and power interruption. Electron number density is evaluated from absolute emissivity of recombinational continuum. The difference between electron Te and heavy particle Th temperature ranged from 4500 K for 3 A to 2300 K for 11 A arc current. By comparing the present with the previously obtained results, using the same arc device but with the introduction of water aerosol, it is concluded that water aerosol reduces the difference Te - Th and brings plasma closer to the partial thermodynamic equilibrium state.

  8. Numerical Study on Characteristics of Argon Radio-Frequency Glow Discharge with Varying gas Pressure

    Institute of Scientific and Technical Information of China (English)

    YU Qian; DENG Yong-Feng; LIU Yue; HAN Xian-Wei

    2008-01-01

    A one-dimensional fluid simulation on argon rf glow discharge with varying linearly gas pressure from 1 Torr to 100 Torr is performed. The model based on mass conservation equations for electron and ion under diffusion and mobility approximation, and the electron energy conservation equation is solved numerically by finite volume method. The numerical results show that a uniform plasma with high density can be obtained from rf glow discharge with varying gas pressure, and the density of plasma becomes higher as the gas pressure varies from 1 Torr to 100 Torr. It is also shown that in the range of the gas pressure from 1 Torr to 100 Torr with the slower rate of varying gas pressure, higher density of plasma can be obtained.

  9. The relationship between inflammation and the coagulation system

    NARCIS (Netherlands)

    Choi, Goda; Schultz, Marcus J; Levi, Marcel; van der Poll, Tom

    2006-01-01

    Inflammation and coagulation play pivotal roles in host defence. As phylogenetically old responses, there is extensive cross-talk between inflammation and coagulation in enabling an adequate immune response against potentially injurious stimuli. Immune cells are important in the initiation of coagul

  10. The immediate and late effects of thyroid hormone (triiodothyronine on murine coagulation gene transcription.

    Directory of Open Access Journals (Sweden)

    Salam Salloum-Asfar

    Full Text Available Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine (T3 and thyroxine (T4 production. Under these conditions, the impact of exogenous T3 on plasma coagulation, and hepatic and vessel-wall-associated coagulation gene transcription was studied in a short- (4 hours and long-term (14 days setting. Comparing euthyroid conditions (normal mice, with hypothyroidism (conditions of a shortage of thyroid hormone and those with replacement by incremental doses of T3, dosages of 0 and 0.5 μg T3/mouse/day were selected to study the impact of T3 on coagulation gene transcription. Under these conditions, a single injection of T3 injection increased strongly hepatic transcript levels of the well-characterized T3-responsive genes deiodinase type 1 (Dio1 and Spot14 within 4 hours. This coincided with significantly reduced mRNA levels of Fgg, Serpinc1, Proc, Proz, and Serpin10, and the reduction of the latter three persisted upon daily treatment with T3 for 14 days. Prolonged T3 treatment induced a significant down-regulation in factor (F 2, F9 and F10 transcript levels, while F11 and F12 levels increased. Activity levels in plasma largely paralleled these mRNA changes. Thbd transcript levels in the lung (vessel-wall-associated coagulation were significantly up-regulated after a single T3 injection, and persisted upon prolonged T3 exposure. Two-week T3 administration also resulted in increased Vwf and Tfpi mRNA levels, whereas Tf levels decreased. These data showed that T3 has specific effects on coagulation, with Fgg, Serpinc1, Proc, Proz, Serpin10 and Thbd responding rapidly, making these likely direct thyroid hormone receptor targets. F2, F9, F10, F11, F12, Vwf, Tf and Tfpi are late responding genes and probably

  11. Diagnosis of overt disseminated intravascular coagulation in critically Ill adults by Sonoclot coagulation analysis.

    Science.gov (United States)

    Wan, Peng; Tong, Hua-Sheng; Zhang, Xing-Qin; Duan, Peng-Kai; Tang, You-Qing; Su, Lei

    2014-08-01

    Disseminated intravascular coagulation (DIC) diagnosis is hampered by the limited availability of reliable clinical or laboratory tests. Currently available tests are time consuming and expensive. We investigated whether coagulation and platelet function analyses using the Sonoclot system were suitable for overt DIC diagnosis in critically ill adults. This was an observational diagnostic study performed in 498 patients presenting with an underlying disorder associated with DIC. Overt DIC patients were identified according to an International Society on Thrombosis and Hemostasis (ISTH) score of >5. Coagulation and platelet parameters were analyzed using the Sonoclot system, and compared with ISTH as the gold standard. Receiver operating characteristic curves and area under the curves were used to evaluate the value of the Sonoclot parameters. There were no differences for age or gender between the groups. Significant correlations were observed between activated clotting time (ACT) and ISTH score (r = 0.7; P coagulation dysfunction in patients with overt DIC.

  12. Coagulation disorders in the patients with deep vein thrombosis of lower extremity

    Directory of Open Access Journals (Sweden)

    Milić Dragan J.

    2003-01-01

    Full Text Available PURPOSE Venous thromboembolism is a relevant social and health care problem for its high incidence, pulmonary embolism-related mortality and long-term sequelae which may be disabling (post-thrombotic syndrome and ulceration. PROCEDURES The aim of our work was to establish the presence of coagulation disorders (hypercoagulable states in the patients with deep vein thrombosis (DVT of the leg. Prospectively we have analyzed a group of 30 patients with echosono-graphicaly verified DVT of the leg who were admitted to the department of vascular surgery from August 1st 2000 to July 31st 2001.The following parameters were monitored: prothrombin time (PT partial thromboplastin time (PTT, fibrinogen (Fib, alpha 2 antiplasmin (A-2 AP, D-dimer (DD, antithrombin III (AT III and factor VII. FINDINGS Activation of the coagulation process was registered. The values of monitored coagulation parameters are shown in table 1. Plasma levels of monitored parameters in the patients with DVT of the leg were significantly higher than in the control subjects. CONCLUSION In patients with a DVT a hypercoagulable state is common finding. Some parameters of coagulation activity such as D-dimer might be of great interest in the diagnostic strategy of DVT.

  13. Enrichment of trace metals in water utilizing the coagulation of soybean protein

    International Nuclear Information System (INIS)

    An enrichment of trace metals in water with a coagulated soybean protein and the complex-forming character of heavy metal ions with the soybean protein were investigated by means of emission spectrography. Fixed amounts of soybean milk (collector) and delta-gluconic lactone (coagulant) were added to a sample solution containing various metal ions, and then the mixture was heated to boiling in order to coagulate the protein. The coagulum (soybean curd) separated from the suspension with a centrifuge was burned to ashes with a low temperature plasma asher. Then metals enriched in the soybean curd were determined by means of emission spectrography. The pH of the solution was adjusted to 4.4--5.0 by adding suitable amounts of delta-gluconic lactone for the complete coagulation of the soybean protein. The proposed method can be applied to the collection and enrichment of various metal ions such as gold, silver, mercury, platinum, cadmium, beryllium, palladium, antimony, gallium, indium, cerium, lanthanum, thorium, yttrium, zirconium, etc. Those metals are not detectable in the original soybean. (auth.)

  14. Blood coagulation factor VIII: An overview

    Indian Academy of Sciences (India)

    G M Bhopale; R K Nanda

    2003-12-01

    Factor VIII (FVIII) functions as a co-factor in the blood coagulation cascade for the proteolytic activation of factor X by factor IXa. Deficiency of FVIII causes hemophilia A, the most commonly inherited bleeding disorder. This review highlights current knowledge on selected aspects of FVIII in which both the scientist and the clinician should be interested.

  15. Laboratory testing in disseminated intravascular coagulation.

    Science.gov (United States)

    Favaloro, Emmanuel J

    2010-06-01

    The diagnosis of disseminated intravascular coagulation (DIC) relies on clinical signs and symptoms, identification of the underlying disease, the results of laboratory testing, and differentiation from other pathologies. The clinical features mainly depend on the underlying cause of the DIC. The laboratory diagnosis of DIC uses a combination of tests because no single test result alone can firmly establish or rule out the diagnosis. Global tests of hemostasis may initially provide evidence of coagulation activation and later in the process provide evidence of consumption of coagulation factors, but their individual diagnostic efficiency is limited. Fibrinolytic markers, in particular D-dimer, are reflective of activation of both coagulation and fibrinolysis, so that a normal finding can be useful for ruling-out DIC. Decreased levels of the natural anticoagulants (in particular, antithrombin and protein C) are frequently observed in patients with DIC, but their measurement is not normally incorporated into standard diagnostic algorithms. New tests are being explored for utility in DIC, and some additional tests may be useful on a case-by-case basis, depending on the proposed cause of the DIC or their local availability. For example, clot waveform analysis is useful but currently limited to a single instrument. Also, procalcitonin is an inflammatory biomarker that may be useful within the context of septic DIC, and activated factor X clotting time is an emerging test of procoagulant phospholipids that also seems to hold promise in DIC.

  16. Brownian coagulation at high particle concentrations

    NARCIS (Netherlands)

    Trzeciak, T. M.

    2012-01-01

    The process of Brownian coagulation, whereby particles are brought together by thermal motion and grow by collisions, is one of the most fundamental processes influencing the final properties of particulate matter in a variety of technically important systems. It is of importance in colloids, emulsi

  17. Chronic Rhinosinusitis and the Coagulation System.

    Science.gov (United States)

    Kim, Dong Young; Cho, Seong H; Takabayashi, Tetsuji; Schleimer, Robert P

    2015-09-01

    Chronic rhinosinusitis (CRS) is one of the most common chronic diseases in adults and severely affects quality of life in patients. Although various etiologic and pathogenic mechanisms of CRS have been proposed, the causes of CRS remain uncertain. Abnormalities in the coagulation cascade may play an etiologic role in many diseases, such as asthma and other inflammatory conditions. While studies on the relationship between asthma and dysregulated coagulation have been reported, the role of the coagulation system in the pathogenesis of CRS has only been considered following recent reports. Excessive fibrin deposition is seen in nasal polyp (NP) tissue from patients with chronic rhinosinusitis with nasal polyp (CRSwNP) and is associated with activation of thrombin, reduction of tissue plasminogen activator (t-PA) and upregulation of coagulation factor XIII-A (FXIII-A), all events that can contribute to fibrin deposition and crosslinking. These findings were reproduced in a murine model of NP that was recently established. Elucidation of the mechanisms of fibrin deposition may enhance our understanding of tissue remodeling in the pathophysiology of NP and provide new targets for the treatment of CRSwNP. PMID:26122502

  18. Haemostatic effects of recombinant coagulation factor VIIa

    NARCIS (Netherlands)

    Lisman, Johannes Antonius

    2003-01-01

    Recombinant coagulation factor VIIa (rFVIIa) has recently become available for treatment of patients with inhibitor-complicated haemophilia. It has been postulated that rFVIIa could become a universal haemostatic agent. Case reports and small studies confirm efficacy and safety of rFVIIa in a variet

  19. Ionization effects in the generation of wake-fields by ultra-high contrast femtosecond laser pulses in argon gas

    Energy Technology Data Exchange (ETDEWEB)

    Makito, K.; Shin, J.-H. [Graduate School of Engineering, Osaka University, 2-1, Yamadaoka, Suita, Osaka (Japan); Zhidkov, A.; Hosokai, T.; Masuda, S. [Photon Pioneers Center, Osaka University, 2-8, Yamadaoka, Suita, Osaka (Japan); Japan Science and Technology Agency (JST), CREST, 2-8 Yamadaoka, Suita, Osaka (Japan); Kodama, R. [Graduate School of Engineering, Osaka University, 2-1, Yamadaoka, Suita, Osaka (Japan); Photon Pioneers Center, Osaka University, 2-8, Yamadaoka, Suita, Osaka (Japan); Japan Science and Technology Agency (JST), CREST, 2-8 Yamadaoka, Suita, Osaka (Japan)

    2012-10-15

    Difference in mechanisms of wake-field generation and electron self-injection by high contrast femtosecond laser pulses in an initially neutral Argon gas and in pre-ionized plasma without ionization is studied via 2D particle-in-cell simulations including optical ionization of the media. For shorter laser pulses, 40 fs, ionization results only in an increase of the charge of accelerated electrons by factor of {approx}3 with qualitatively the same energy distribution. For longer pulses, 80 fs, a more stable wake field structure is observed in the neutral gas with the maximal energy of the accelerated electrons exceeding that in the fixed density plasma. In higher density Argon, an ionizing laser pulse converts itself to a complex system of solitons at a self-induced, critical density ramp.

  20. Ionization effects in the generation of wake-fields by ultra-high contrast femtosecond laser pulses in argon gas

    Science.gov (United States)

    Makito, K.; Zhidkov, A.; Hosokai, T.; Shin, J.-H.; Masuda, S.; Kodama, R.

    2012-10-01

    Difference in mechanisms of wake-field generation and electron self-injection by high contrast femtosecond laser pulses in an initially neutral Argon gas and in pre-ionized plasma without ionization is studied via 2D particle-in-cell simulations including optical ionization of the media. For shorter laser pulses, 40 fs, ionization results only in an increase of the charge of accelerated electrons by factor of ˜3 with qualitatively the same energy distribution. For longer pulses, 80 fs, a more stable wake field structure is observed in the neutral gas with the maximal energy of the accelerated electrons exceeding that in the fixed density plasma. In higher density Argon, an ionizing laser pulse converts itself to a complex system of solitons at a self-induced, critical density ramp.

  1. Thymoquinone Modulates Blood Coagulation in Vitro via Its Effects on Inflammatory and Coagulation Pathways

    OpenAIRE

    Vandhana Muralidharan-Chari; Jaehan Kim; Ahlam Abuawad; Mubeena Naeem; Huadong Cui; Mousa, Shaker A

    2016-01-01

    Thymoquinone (THQ) is a major component of black seeds. Given that both THQ and black seeds exhibit anti-cancer and anti-inflammatory activities, we hypothesized that THQ will affect cancer-associated thrombosis (CAT), which is primarily triggered by tissue factor (TF) and inflammation. The effect of both black seed-extracted and purchased (“pure”) THQ on normal blood coagulation was tested with in vitro thromboelastography (TEG) and activated partial thromboplastin time (aPTT) coagulation as...

  2. Argon 4s and 4p Excited States Atomic Data Applied in ARC-JET Modeling

    Directory of Open Access Journals (Sweden)

    K. Katsonis

    2011-01-01

    Full Text Available Evaluated atomic data concerning the 4s and 4p configurations of Ar I are averaged in order to simplify their use in various cases of Ar plasma modeling and diagnostics. These data are used here to model a low-power arcjet, running with Argon at low pressure. In so doing, they are explicitly introduced in the chemical processes included in a fluid Navier-Stokes type code, allowing for evaluation of the spectroscopically measurable level populations and of the electronic temperatures. The characteristics of the model are described and the main processes are discussed in view of the results of the calculations.

  3. Extreme ultraviolet spectroscopy of highly charged argon ions at the Berlin EBIT

    Energy Technology Data Exchange (ETDEWEB)

    Biedermann, C; Radtke, R; Fussmann, G; Allen, F I [Institut fuer Physik der Humboldt-Universitaet zu Berlin, Lehrstuhl Plasmaphysik, Newtonstrass 15, 12489 Berlin and Max-Planck-Institut fuer Plasmaphysik, EURATOM Association (Germany)

    2007-06-15

    Extreme ultraviolet radiation from highly charged argon was investigated at the Berlin Electron Beam Ion Trap with a 2 m grazing incidence spectrometer. Lines in the wavelength range 150 to 660 A originating from C-like Ar{sup 12+}to Li-like Ar{sup 15+}ions have been identified and are compared with database information from solar line lists and predictions. Line ratios for the observed resonance, intercombination and forbidden lines offer important diagnostic capabilities for low density, hot plasmas.

  4. Clinical effect of co-infusion of fresh frozen plasma and cryoprecipitate on blood coagulation function in patients with postpartum hemorrhage%新鲜冰冻血浆联合冷沉淀输注对产后大出血患者凝血功能影响

    Institute of Scientific and Technical Information of China (English)

    陈涌泉; 王厚照; 吕小英; 张毓

    2015-01-01

    Objective: To observe the clinical effect of co-infusion of fresh frozen plasma(FFP) and cryoprecipitate(Cryo) to raise the levels of fibrinogen(Fbg)and fibronectin(Fn)in patients with postpartum hemorrhage. Methods: Patients with postpartum hemorrhage were randomly divided into three groups , Group A: FFP and Cryo co-infusion group( n=25), Group B:FFP infusion group( n=23), Group C:Cryo infusion group( n=24). The levels of Fbg and Fn were determined 1 hour before infusion and 3-12 hours after infusion. Results: Compared to the FFP infusion group and Cryo infusion group, the levels of Fbg and Fn of FFP and Cryo co-infusion group were both significantly higher with the changes containing statistical significance. Conclusion: FFP and Cryo co-infusion could significantly raise the levels of Fbg and Fn in patients with postpartum hemorrhage, which could improve their coagulation functions and promote their hemostatic functions.%目的:观察新鲜冰冻血浆(FFP)和冷沉淀(Cryo)联合输注提升产后大出血患者血液中纤维蛋白原(Fbg)和纤维结合蛋白(Fn)水平的临床效果。方法:72例产后大出血患者分为3组, A 组:FFP 联合 Cryo 输注组(共25例),B 组:FFP 输注组(共23例),C 组:Cryo 输注组(共24例)。输注前1h 和输注后3~12h 测定血液中 Fbg 和 Fn 含量。结果:与 FFP 输注组和 Cryo 输注组相比,FFP 联合 Cryo 输注组输注后 Fbg 和 Fn 含量均明显上升,差异有统计学意义(P<0.05)。结论:FFP 和 Cryo 联合输注比单独输注 FFP 或 Cryo 更能有效提升患者血液中 Fbg 和 Fn 含量,改善大出血产妇凝血功能状况和促进止血。

  5. Large vessel sealing with the argon laser.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; Lyons, R; White, G; Klein, S R; Pizzurro, D; Abergel, R P; Dwyer, R M; Uitto, J

    1987-01-01

    This study compared the histology, biochemistry, and tensile strength of laser-welded and sutured canine venotomies, arteriotomies, and arteriovenous fistulas. Twelve animals had bilateral femoral vessels studied, with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralateral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks (four animals for each type of repair), and were evaluated histologically by hematoxylin and eosin, elastin, and trichrome stains; biochemically by the formation of [3H]hydroxyproline as an index of collagen synthesis; and mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms, or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welding may be an alternative to sutures for repair of large-diameter venotomies, arteriotomies, and arteriovenous fistulas, as healing is comparable to that seen with suture repairs up to 4 weeks postoperatively. PMID:3306233

  6. Vascular Welding Using The Argon Laser

    Science.gov (United States)

    White, Rodney A.; Donayre, Carlos; Kopchok, George; White, Geoffrey; Abergel, R. Patrick; Lyons, Richard; Klein, Stanley; Dwyer, Richard; Uitto, Jouni

    1987-03-01

    This study compared the histology, biochemistry, and tensile strength of laser welded and sutured canine venotomies, arteriotomies and arteriovenous fistulas. Bilateral femoral, carotid or jugular vessels were studied with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralatral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks for each type of repair and evaluated histologically by hematoxylineosin, elastin and trichrome stains, biochemically by the formation of [3H] hyaroxyproline as an index of collagen synthesis, ana mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welaing may be an alternative to sutures for repair of large diameter venotomies, arteriotomies and arteriovenous fistulas, as they heal comparable to suture repairs up to 4 weeks postoperatively.

  7. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  8. Optimized coagulation of high alkalinity, low temperature and particle water: pH adjustment and polyelectrolytes as coagulant aids.

    Science.gov (United States)

    Yu, Jianfeng; Wang, Dongsheng; Yan, Mingquan; Ye, Changqing; Yang, Min; Ge, Xiaopeng

    2007-08-01

    The Yellow River in winter as source water is characterized as high alkalinity, low temperature and low particle concentrations, which have brought many difficulties to water treatment plants. This study fully examines the optimized coagulation process of the Yellow River by conventional and pre-polymerized metal coagulants, pH adjustment and polyelectrolytes as the primary coagulants or coagulant aids. For all the metal coagulants, polyaluminum chlorides are superior to traditional metal coagulants due to their stable polymeric species and low consumption of alkalinity. The removal of natural organic matter by monomeric metal coagulants can be improved through pH adjustment, which is in accordance with the higher concentration of polymeric species formed at corresponding pH value. With the addition of polyelectrolytes as coagulant aids, the coagulation performance is significantly improved. The effective removal of dissolved organic matter is consistent with high charge density, while molecular weight is relatively important for removing particles, which is consistent with polyelectrolytes as primary coagulants. These results suggest that the coagulation mechanisms in the removal of dissolved organic matter and particles are different, which may be exploited for optimized coagulation for the typical source water in practice.

  9. Improvement of paint effluents coagulation using natural and synthetic coagulant aids.

    Science.gov (United States)

    Aboulhassan, M A; Souabi, S; Yaacoubi, A; Baudu, M

    2006-11-01

    The coagulant iron chloride and the flocculants Polysep 3000 (PO), Superfloc A-1820 (SU) and Praestol 2515 TR (PR) have been used in this study to show the efficiency of coagulation flocculation process in the chemical precipitation method for the removal of organic and colouring matters from the paint industry wastewater. This study also includes the amount of produced sludge. The results indicate that FeCl(3) is efficient at pH range 8-9 and at optimal dose of 650 mgl(-1). Iron chloride allows the removal of 82% of chemical oxygen demand (COD) and 94% of colour. However, sequential addition of coagulant and polymeric additives enhance clearly pollutant removal and produces less decanted sludge compared to the results obtained when the coagulant is used alone. The removal efficiency of COD reaches 91% and that of colour 99%. Coagulation-biflocculation process is more effective than the coagulation-monoflocculation one. The sequential addition of iron chloride, Polysep 3000 (cationic flocculant) and Praestol 2515 TR (anionic flocculant) seems to be the most suitable combination for the treatment of the paint industry wastewaters.

  10. Study on the removal of acid dyes using chitosan as a natural coagulant/coagulant aid.

    Science.gov (United States)

    Zonoozi, M H; Alavi Moghaddam, M R; Arami, M

    2011-01-01

    Chitosan was selected as a natural coagulating agent for the removal of acid dyes (Acid Blue 292; AB292, and Acid Red 398; AR398) from dye-containing solutions. The study was organised in two phases. In phase 1, chitosan was used alone as a natural coagulant for the removal of the dyes. For this purpose, the effect of different parameters including pH, chitosan dosage and initial dye concentration on the dye removal efficiency was examined. In phase 2 of the study, the application of chitosan as a natural coagulant aid in conjunction with polyaluminium chloride (PAC) was assessed. According to the results of phase 1, the best removal efficiencies occurred in an acidic pH range (less than 6) for both of the dyes. Also, excellent dye removal results (about 90%) were achieved with relatively low dosages of chitosan (30-35 mg L(-1) for AB292 and 50-60 mg L(-1) for AR398). However, the initial concentration of the dyes severely influenced the coagulation performance of chitosan, which can constrain the performance of chitosan as a natural coagulant. On the basis of the results of phase 2, chitosan, as a natural coagulant aid, noticeably enhanced the dye removal efficiency of PAC, especially in the case of AB292. Small amounts of chitosan (3 or 5 mg L(-1)) enhanced the dye removal efficiency of PAC up to 2.5 times for AB292.

  11. Color center laser optogalvanic spectroscopy of lithium, barium, neon and argon Rydberg states in hollow cathode discharges

    International Nuclear Information System (INIS)

    Numerous infrared transitions between Rydberg states of neon and argon have been measured by optogalvanic spectroscopy in commercial hollow cathode lamps using a color center laser operating in the range 3600-4100 cm-1. Transitions in lithium and barium atoms sputtered from the cathodes were also detected. The generality and high sensitivity of this technique indicates potential applications for frequency calibration in the infrared, atomic and molecular spectroscopy, and plasma diagnostics. (orig.)

  12. Operating a radio-frequency plasma source on water vapor

    International Nuclear Information System (INIS)

    A magnetically enhanced radio-frequency (rf) plasma source operating on water vapor has an extensive list of potential applications. In this work, the use of a rf plasma source to dissociate water vapor for hydrogen production is investigated. This paper describes a rf plasma source operated on water vapor and characterizes its plasma properties using a Langmuir probe, a residual gas analyzer, and a spectrometer. The plasma source operated first on argon and then on water vapor at operating pressures just over 300 mtorr. Argon and water vapor plasma number densities differ significantly. In the electropositive argon plasma, quasineutrality requires ni≅ne, where ni is the positive ion density. But in the electronegative water plasma, quasineutrality requires ni+=ni-+ne. The positive ion density and electron density of the water vapor plasma are approximately one and two orders of magnitude lower, respectively, than those of argon plasma. These results suggest that attachment and dissociative attachment are present in electronegative water vapor plasma. The electron temperature for this water vapor plasma source is between 1.5 and 4 eV. Without an applied axial magnetic field, hydrogen production increases linearly with rf power. With an axial magnetic field, hydrogen production jumps to a maximum value at 500 W and then saturates with rf power. The presence of the applied axial magnetic field is therefore shown to enhance hydrogen production.

  13. 早发型重度子痫前期合并器官功能障碍患者可溶性内皮抑素、内皮素-1与凝血功能的变化及意义%Serum soluble Endoglin, plasma endothelin-1 and coagulation function in early onset severe preeclampsia with organ dysfunction

    Institute of Scientific and Technical Information of China (English)

    张立军; 韩玉环; 韩玉植

    2010-01-01

    Objective To investigate the expression levels of serum soluble Endoglin (sEng), plasma endothelin-1 (ET-1) and coagulation function in patients suffering from early onset severe preeclampsia with organ dysfunction, and to analyze the clinical significance. Methods Forty-nine early onset severe preeclampsia patients were enrolled in the study group, including 26 cases without organ dysfunction (study group Ⅰ) and 23 cases with organ dysfunction (study group Ⅱ). The control group included 30 cases of health pregnant women during the same period of gestation. The serum levels of sEng and plasma ET-1 were analyzed with enzyme-linked immunosorbent assay (ELISA), coagulation function was determined at the same time, and the relationship between the change in levels of sEng, ET-1, coagulation function and organ function, and also outcome of perinatal infants. Results ① The levels of sEng, ET-1, fibrinogen (Fib) and mean platelet volume (MPV) of the study group Ⅰ and I were significantly higher compared with control group (sEng,μg/L:10.96±3.21, 14.17±4.02vs. 7.49±2.73; ET-1, μg/L: 41.54 ± 10. 37, 65.91± 12.46vs. 24.56±6.26; Fib, g/L:4.41±1.02,5.35±1.17vs. 3.69±0.82; MPV, fl:11. 71± 1.21, 13.89±1.76vs. 11.03±0.82, all P< 0.05), and prothrombin time (PT), activated partial thromboplastin time (APTT) and platelet (PLT) were significantly lower compared with control group (PT, s:10.73±1.82, 8.37±1.51vs. 12.95±1.91; APTT, s:26.14±4.32, 22.69±3.77vs. 30.25±4.71; PLT,×109/L; 164.17±50.67, 136.43±51.21vs. 201.63±59.83, all P<0.05). There were also statistical significances in all the values between study group Ⅰ and I (all P<0.05). ②There was positive correlation between the sEng level and systolic pressure, diastolic pressure, Fib, urine protein of 24 hours, serum creatinine (SCr); there was negative correlation between the sEng level and albumin (Alb) content, PT, estriol/creatinine (E/C) of 12-hour urine, fetal birth weight (all P

  14. The removal of anionic surfactants from water in coagulation process.

    Science.gov (United States)

    Kaleta, Jadwiga; Elektorowicz, Maria

    2013-01-01

    This paper presents the results of a laboratory study on the effectiveness of the coagulation process in removing surfactants from water. The application of traditional coagulants (aluminium sulfate and iron chlorides) has not brought satisfactory results, the reduction in anionic surfactant (AS) content reached 7.6% and 10%, respectively. Adding cationic polyelectrolyte (Zetag-50) increased the removal efficiency to 24%. Coagulation using a polyelectrolyte alone proved to be more efficient, the reduction in surfactant content fluctuated at a level of about 50%. Complete surfactant removal was obtained when powdered activated carbon was added 5 minutes before the basic coagulant to the coagulation process. The efficiency of surfactant coagulation also increased after the application of powdered clinoptilolite, but to a smaller degree. Then the removal of AS was found to be improved by dosing powdered clinoptilolite simultaneously or with short delay after the addition of the basic coagulant. PMID:23837351

  15. Argon laser induced changes to the carbonate content of enamel

    International Nuclear Information System (INIS)

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm-2) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  16. Simplifying plasma chemistry via ILDM

    Science.gov (United States)

    Rehman, T.; Kemaneci, E.; Graef, W.; van Dijk, J.

    2016-02-01

    A plasma fluid model containing a large number of chemical species and reactions yields a high computational load. One of the methods to overcome this difficulty is to apply Chemical Reduction Techniques as used in combustion engineering. The chemical reduction technique that we study here is ILDM (Intrinsic Lower Dimensional Manifold). The ILDM method is used to simplify an argon plasma model and then a comparison is made with a CRM (Collisional Radiative Model).

  17. Surface treatment of polypropylene (PP) film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

    International Nuclear Information System (INIS)

    Thin films of polypropylene (PP) are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. PP samples before and after the treatments are studied using contact angle measurements, surface free energy calculations and scanning electron microscopy (SEM). Distilled water (H2O), glycerol (C3H8O3) and diiodomethane (CH2I2) are used as test liquids. The contact angle measurements between test liquids and PP samples are used to determine total surface free energy using sessile drop technique. PP films show a remarkable increase in surface free energy after plasma treatment. SEM analysis of the plasma-treated PP films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably

  18. Surface treatment of high density polyethylene (HDPE film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

    Directory of Open Access Journals (Sweden)

    Joshi Ujjwal Man

    2015-03-01

    Full Text Available Thin films of high density polyethylene (HDPE are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. HDPE samples before and after the treatment are studied using contact angle measurements, surface free energy calculations and atomic force microscopy (AFM. Distilled water (H2O, glycerol (C3H8O3 and diiodomethane (CH2I2 are used as test liquids. The contact angle measurements between test liquids and HDPE samples are used to determine total surface free energy using sessile drop technique. HDPE films show a remarkable increase in surface free energy after plasma treatment. AFM analysis of the plasma-treated HDPE films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.

  19. Surface treatment of polypropylene (PP) film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

    Science.gov (United States)

    Joshi, Ujjwal Man; Subedi, Deepak Prasad

    2015-07-01

    Thin films of polypropylene (PP) are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. PP samples before and after the treatments are studied using contact angle measurements, surface free energy calculations and scanning electron microscopy (SEM). Distilled water (H2O), glycerol (C3H8O3) and diiodomethane (CH2I2) are used as test liquids. The contact angle measurements between test liquids and PP samples are used to determine total surface free energy using sessile drop technique. PP films show a remarkable increase in surface free energy after plasma treatment. SEM analysis of the plasma-treated PP films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.

  20. Effect of Iron and Carbon Monoxide on Fibrinogenase-like Degradation of Plasmatic Coagulation by Venoms of Six Agkistrodon Species.

    Science.gov (United States)

    Nielsen, Vance G; Redford, Daniel T; Boyle, Patrick K

    2016-05-01

    Annually, thousands suffer poisonous snakebite, often from defibrinogenating species. It has been demonstrated that iron and carbon monoxide change the ultrastructure of plasma thrombi and improve coagulation kinetics. Thus, this investigation sought to determine whether pre-treatment of plasma with iron and carbon monoxide could attenuate venom-mediated catalysis of fibrinogen obtained from Agkistrodon species with fibrinogenase activity. Human plasma was pre-treated with ferric chloride (0-10 μM) and carbon monoxide-releasing molecule-2 (CORM-2, 0-100 μM) prior to exposure to 0.5-11 μg/ml of six different Agkistrodon species' venom. The amount of venom used for experimentation needed to decrease coagulation function of one or more kinetic parameters by at least 50% of normal values for (e.g. half the normal speed of clot formation). Coagulation kinetics were determined with thrombelastography. All six snake venoms degraded plasmatic coagulation kinetics to a significant extent, especially prolonging the onset to clot formation and diminishing the speed of clot growth. Pre-treatment of plasma with iron and carbon monoxide attenuated these venom-mediated coagulation kinetic changes in a species-specific manner, with some venom effects markedly abrogated while others were only mildly decreased. Further in vitro investigation of other pit viper venoms that possess fibrinogenolytic activity is indicated to identify species amenable to or resistant to iron and carbon monoxide-mediated attenuation of venom-mediated catalysis of fibrinogen. Lastly, future pre-clinical investigation with animal models (e.g. rabbit ear-bleed model) is planned to determine whether iron and carbon monoxide can be used therapeutically after envenomation. PMID:26467642