WorldWideScience

Sample records for argon fluorides

  1. Surface Chemistry of Polymers Physical Adsorption of Nitrogen, Argon, Sulfur Dioxide and Neopentane on Polyvinylidene Fluoride

    OpenAIRE

    Houriet, Jean-Philippe; Ghiste, Patrick; Stoeckli, Fritz

    2007-01-01

    The adsorption of nitrogen, argon, sulfur dioxide and neopentane on polyvinylidene fluoride has been measured by static methods and by gas-solid chromatography. The polymer has a homogeneous surface of low energy, which is not significantly affected by heating.

  2. Fluoride

    Science.gov (United States)

    Fluoride is used to prevent tooth decay. It is taken up by teeth and helps to strengthen ... and block the cavity-forming action of bacteria. Fluoride usually is prescribed for children and adults whose ...

  3. A comparative study to evaluate the effect of fluoride releasing sealant cured by visible light, argon laers, and light emitting diode curing units: An in vitro study

    Directory of Open Access Journals (Sweden)

    Das U

    2009-09-01

    Full Text Available In Pediatric Dentistry, the use of pit and fissure sealant is one of the essential forms of prevention. Pit and fissure caries may be substantially decreased by obliteration of these developmental defects in occlusal, buccal and lingual surfaces with resin based dental sealants. Visible light-curing units, or LCUs, are an integral part of modern adhesive dentistry" They are used to cure resin based composite restoration materials, resin modified glass-ionomer and pit and fissure sealants, as well as to bond orthodontic teeth. Most recently, the argon laser has been approved for initiating the setting reaction with visible light cured-resins. Argon curing of resin materials has been show to enhance the physical properties and degree of polymerization of the resin, while reducing the polymerization time by 75 percent. The study is undertaken considering the inadequate research reports of regarding the comparison of curing ability using argon laser. LEDs and visible light as well as the resistant towards caries activity of the preventive fluoride releasing pit and fissure sealant cured by above mentioned curing units.

  4. Infrared spectra of UF6, WF6, MoF6, and SF6 complexes with hydrogen fluoride in solid argon

    International Nuclear Information System (INIS)

    UF6, WF6, MoF6, and SF6 have been codeposited with hydrogen fluoride in excess argon at 12 K. The FTIR spectra of UF6 and HF revealed a strong UF6-HF complex absorption at 3,848 cm-1 along with a weak, broad band at 3,903 cm-1 due to the UF6-FH complex. Only one 1:2 complex with a UF6-HaF-HbF arrangement was detected at higher HF concentrations and sample annealings. Similarly, the HF interaction with tungsten hexafluoride formed two 1:1 complexes. However, the 3,884-cm-1 band due to the anti-hydrogen-bonded complex WF6-FH was considerably stronger than the WF6-FHb-FHa structure. The band positions and relative intensities for the MoF6 complexes with HF and DF were very comparable to their WF6 counterparts

  5. Fluoridated Water

    Science.gov (United States)

    ... Cancer Prevention Overview–for health professionals Research Fluoridated Water On This Page What is fluoride, and where is it found? What is water fluoridation? When did water fluoridation begin in the ...

  6. Bottled Water and Fluoride

    Science.gov (United States)

    ... Fluoridation Journal Articles for Community Water Fluoridation Bottled Water Recommend on Facebook Tweet Share Compartir Consumers drink ... questions about bottled water and fluoride. Does bottled water contain fluoride? Bottled water products may contain fluoride, ...

  7. Metal fluorides

    International Nuclear Information System (INIS)

    Systems formed by fluorides of alkali, alkali earth, rare earth elements, yttrium, zirconium, hafnium, bismuth, antimony are investigated with the aim of preparing new fluoride materials and studying their thermodynamic and other physical and chemical properties. The respective phase diagrams are plotted. On the basis of the research fluoroberyllate glasses with rare earth additions of improved qualities (moisture resistance, crystallization resistance, resistance against radiation up to 100 Mrad) are prepared. The rho-T-x phase diagrams of the systems studied show that many compounds are sublimated congruently at certain temperatures and incongruently - above them. The existence of congruently sublimated compounds and azeotropically sublimated compositions provides for the preparation of uniform optical films. In connection with the search for new materials-luminophores and matrices of optical quantum generators - the fluoride systems of alkali metals and lanthanides are studied; the formation of binary fluorides of M3LnF6, M2LnF5, MLnF4, MLn2F7, MLn3F10 compositions is established. To search for new solid electrolytes, the solid-phase interaction of Sb-and Bi trifluorides with their oxides and alakali metal fluorides is studied. The electric conductivity of the compounds obtained is studied

  8. Formation of argon-boron bonds in the reactions of BFn+/2+ cations with neutral argon

    Czech Academy of Sciences Publication Activity Database

    Levee, L.; Calogero, C.; Barbieri, E.; Byrne, S.; Donahue, C.; Eisenberg, M.; Hattenbach, S.; Le, J.; Capitani, J. F.; Roithová, J.; Schröder, Detlef

    2012-01-01

    Roč. 323, 1 Jun (2012), s. 2-7. ISSN 1387-3806 R&D Projects: GA ČR GA203/09/1223 Grant ostatní: European Research Council(XE) AdG HORIZOMS Institutional support: RVO:61388963 Keywords : argon compound * boron fluoride * dication * gas phase reactivity * mass spectrometry * neon compound Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.142, year: 2012

  9. Fluoridation Basics

    Science.gov (United States)

    ... level in water is not enough to prevent tooth decay; however, some groundwater and natural springs can have ... the tooth’s surface, or enamel. Water fluoridation prevents tooth decay by providing frequent and consistent contact with low ...

  10. Argon plasma coagulation

    Directory of Open Access Journals (Sweden)

    Zenker, Matthias

    2008-03-01

    Full Text Available Argon Plasma Coagulation (APC is an application of gas discharges in argon in electrosurgery, which is increasingly used especially in endoscopy. The major application fields are haemostasis, tissue devitalization and tissue reduction.This review describes the physics and technology of electrosurgery and APC. Some characteristics of the argon discharge are shown and discussed, and thermal effects in biological tissue are described. Subsequently, examples of medical applications are given.

  11. How Does Fluoride Work?

    Science.gov (United States)

    ... the mid-1940s, communities started to put more fluoride in their water supplies to protect people against tooth decay. Fluoride ... might suggest supplements — which are like vitamins containing fluoride. Just how effective is fluoridated water? Thanks to it, dentists say half of kids ...

  12. Fluoride and Dental Health

    OpenAIRE

    Nikiforuk, Gordon

    1988-01-01

    Studies conducted under the widest variety of controlled conditions attest to the safety, efficacy, and cost benefits of fluoridation. A program that combines the use of systemic and topical fluoride results in maximum benefits. The author of this article reviews the metabolism of fluoride and its mechanism of action, and discusses practical modes of employing fluoride in caries prevention with special emphasis on the use of fluoride supplements for infants and young children in areas of non-...

  13. Lunar exospheric argon modeling

    Science.gov (United States)

    Grava, Cesare; Chaufray, J.-Y.; Retherford, K. D.; Gladstone, G. R.; Greathouse, T. K.; Hurley, D. M.; Hodges, R. R.; Bayless, A. J.; Cook, J. C.; Stern, S. A.

    2015-07-01

    Argon is one of the few known constituents of the lunar exosphere. The surface-based mass spectrometer Lunar Atmosphere Composition Experiment (LACE) deployed during the Apollo 17 mission first detected argon, and its study is among the subjects of the Lunar Reconnaissance Orbiter (LRO) Lyman Alpha Mapping Project (LAMP) and Lunar Atmospheric and Dust Environment Explorer (LADEE) mission investigations. We performed a detailed Monte Carlo simulation of neutral atomic argon that we use to better understand its transport and storage across the lunar surface. We took into account several loss processes: ionization by solar photons, charge-exchange with solar protons, and cold trapping as computed by recent LRO/Lunar Orbiter Laser Altimeter (LOLA) mapping of Permanently Shaded Regions (PSRs). Recycling of photo-ions and solar radiation acceleration are also considered. We report that (i) contrary to previous assumptions, charge exchange is a loss process as efficient as photo-ionization, (ii) the PSR cold-trapping flux is comparable to the ionization flux (photo-ionization and charge-exchange), and (iii) solar radiation pressure has negligible effect on the argon density, as expected. We determine that the release of 2.6 × 1028 atoms on top of a pre-existing argon exosphere is required to explain the maximum amount of argon measured by LACE. The total number of atoms (1.0 × 1029) corresponds to ∼6700 kg of argon, 30% of which (∼1900 kg) may be stored in the cold traps after 120 days in the absence of space weathering processes. The required population is consistent with the amount of argon that can be released during a High Frequency Teleseismic (HFT) Event, i.e. a big, rare and localized moonquake, although we show that LACE could not distinguish between a localized and a global event. The density of argon measured at the time of LACE appears to have originated from no less than four such episodic events. Finally, we show that the extent of the PSRs that trap

  14. Depleted Argon from Underground Sources

    International Nuclear Information System (INIS)

    Argon is a strong scintillator and an ideal target for Dark Matter detection; however 39Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in 39Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO2 well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO2. We first concentrate the argon locally to 3% in an Ar, N2, and He mixture, from the CO2 through chromatographic gas separation, and then the N2 and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO2 facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

  15. Hair as Biomarker of Fluoride Exposure in a Fluoride Endemic Area and a Low Fluoridated Area

    OpenAIRE

    Parimi, Nalini; V. Viswanath; Kashyap, Bina; Patil, Pavan Uday

    2013-01-01

    Aim: The aim of the present study was to determine whether hair could be used as biomarker of fluoride exposure. Materials and Methods: The study was carried out on 30 people living in an endemically fluoridated area and a low fluoridated area. Samples of hair from the occipital were taken and subjected to fluoride analysis by a fluoride ion electrode. Results: Lower fluoride levels in water supplies correlated with lower levels of fluoride in hair and more over higher fluoride levels in wate...

  16. Effect of fluoride dentifrices on salivary fluoride levels in children.

    OpenAIRE

    Paul S; Tandon S; Murthy K

    1993-01-01

    Fluoride dentifrices are well accepted for their caries preventive effects. The fluoride concentration in the oral fluids after tooth brushing with fluoride dentifrices may have an important relationship to the caries reducing capacity. The present study was aimed to clinically evaluate the salivary fluoride retention of dentifrices containing low fluoride concentration in 50 children, aged 7-9 years before, during and after the use of fluoride toothpaste. Estimation of fluoride in saliva was...

  17. Argon in action

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    Over the past few days, the SPS has been accelerating argon ions, which have started to be sent to the NA61/SHINE experiment. This operating mode, using a new type of ion, required a number of modifications to the accelerator.   Picture 1: a “super-cycle” of the SPS, featuring a proton cycle for the LHC, followed by an argon ion cycle for the North Area. Today, the accelerators are once again juggling particles and even performing completely new tricks. The SPS is supplying beams of argon ions for the first time, at energies never before achieved for this type of beam. They are destined for the NA61/SHINE experiment (see box) located in the North Area, which began receiving the beams on 11 February. Argon ions have a relatively large mass, as they consist of 40 nucleons, so they can be used in a similar way to lead ions. The main difficulty in accelerating them lies in the SPS, where the variation in acceleration frequency is limited. “The SPS was designed for a...

  18. Thermophysical properties of argon

    Energy Technology Data Exchange (ETDEWEB)

    Jaques, A.

    1988-02-01

    The entire report consists of tables of thermodynamic properties (including sound velocity, thermal conductivity and diffusivity, Prandtl number, density) of argon at 86 to 400/degree/K, in the form of isobars over 0.9 to 100 bars. (DLC)

  19. Fluoride glass fiber optics

    CERN Document Server

    Aggarwal, Ishwar D

    1991-01-01

    Fluoride Glass Fiber Optics reviews the fundamental aspects of fluoride glasses. This book is divided into nine chapters. Chapter 1 discusses the wide range of fluoride glasses with an emphasis on fluorozirconate-based compositions. The structure of simple fluoride systems, such as BaF2 binary glass is elaborated in Chapter 2. The third chapter covers the intrinsic transparency of fluoride glasses from the UV to the IR, with particular emphasis on the multiphonon edge and electronic edge. The next three chapters are devoted to ultra-low loss optical fibers, reviewing methods for purifying and

  20. Fluoride levels and osteosarcoma

    Directory of Open Access Journals (Sweden)

    Simmi Kharb

    2012-01-01

    Full Text Available Context: Osteosarcoma is a rare malignant bone tumor, commonly occurring in the age group of 10 to 24 years. Recent reports have indicated that there is a link between fluoride exposure and osteosarcoma. Aims: The present study was planned to analyze serum levels of fluoride in patients of osteosarcoma and fluoride content of their drinking water. Settings and Design: The present study was carried out comparing 10 patients of osteosarcoma and 10 healthy volunteers (who served as controls. Materials and Methods: Serum and drinking water fluoride levels were estimated by ion selective electrode. Statistical analysis used: The data were computed as mean ± SD and Student′s t test was applied. Results: Both, the serum and drinking water fluoride levels, were significant by higher in patients with osteosarcoma as compared to controls (P < 0.05, P < 0.001, respectively. Conclusions: These results suggest a link between fluoride exposure and osteosarcoma.

  1. Fluoride toothpastes and fluoride mouthrinses for home use

    OpenAIRE

    Andrew Rugg-Gunn; Jolan Bánóczy

    2013-01-01

    Objective. To provide a brief commentary review of fluoride-containing toothpastes and mouthrinses with emphasis on their use at home. Toothpastes and mouthrinses are just two of many ways of providing fluoride for the prevention of dental caries. The first investigations into incorporating fluoride into toothpastes and mouthrinses were reported in the middle 1940s. Unlike water fluoridation (which is ‘automatic fluoridation’), fluoride-containing toothpastes and fluoride-containing mouthrins...

  2. Fluoride and Oral Health.

    Science.gov (United States)

    O'Mullane, D M; Baez, R J; Jones, S; Lennon, M A; Petersen, P E; Rugg-Gunn, A J; Whelton, H; Whitford, G M

    2016-06-01

    The discovery during the first half of the 20th century of the link between natural fluoride, adjusted fluoride levels in drinking water and reduced dental caries prevalence proved to be a stimulus for worldwide on-going research into the role of fluoride in improving oral health. Epidemiological studies of fluoridation programmes have confirmed their safety and their effectiveness in controlling dental caries. Major advances in our knowledge of how fluoride impacts the caries process have led to the development, assessment of effectiveness and promotion of other fluoride vehicles including salt, milk, tablets, toothpaste, gels and varnishes. In 1993, the World Health Organization convened an Expert Committee to provide authoritative information on the role of fluorides in the promotion of oral health throughout the world (WHO TRS 846, 1994). This present publication is a revision of the original 1994 document, again using the expertise of researchers from the extensive fields of knowledge required to successfully implement complex interventions such as the use of fluorides to improve dental and oral health. Financial support for research into the development of these new fluoride strategies has come from many sources including government health departments as well as international and national grant agencies. In addition, the unique role which industry has played in the development, formulation, assessment of effectiveness and promotion of the various fluoride vehicles and strategies is noteworthy. This updated version of 'Fluoride and Oral Health' has adopted an evidence-based approach to its commentary on the different fluoride vehicles and strategies and also to its recommendations. In this regard, full account is taken of the many recent systematic reviews published in peer reviewed literature. PMID:27352462

  3. Fluoride varnishes and enamel caries

    OpenAIRE

    De Bruyn, Hugo

    1987-01-01

    Topical fluoride applications have the aim of increasing the fluoride uptake in enamel and consequently reducing caries. In the early ‘60s fluoride varnishes were introduced because they had a long contact period with the enamel which resulted in a higher fluoride uptake than from other topical applications. Recently the importance of small amounts of fluoride in caries prevention and remineralization has been stressed and the importance of large arnounts of fluoride acquired in the teeth is ...

  4. The Argon Geochronology Experiment (AGE)

    Science.gov (United States)

    Swindle, T. D.; Bode, R.; Fennema, A.; Chutjian, A.; MacAskill, J. A.; Darrach, M. R.; Clegg, S. M.; Wiens, R. C.; Cremers, D.

    2006-01-01

    This viewgraph presentation reviews the Argon Geochronology Experiment (AGE). Potassium-Argon dating is shown along with cosmic ray dating exposure. The contents include a flow diagram of the Argon Geochronology Experiment, and schematic diagrams of the mass spectrometer vacuum system, sample manipulation mechanism, mineral heater oven, and the quadrupole ion trap mass spectrometer. The Laser-Induced Breakdown Spectroscopy (LIBS) Operation with elemental abundances is also described.

  5. Liquid argon neutrino detectors

    CERN Document Server

    Battistoni, G

    2001-01-01

    The liquid argon imaging technique, as proposed for the ICARUS detector, offers the possibility to perform complementary and simultaneous measurements of neutrinos, as those of CERN to Gran Sasso beam (CNGS) and those from cosmic ray events. For the currently allowed values of the Super-Kamiokande results, the combination of both CNGS and atmospheric data will provide a precise determination of the oscillation parameters. Since one can observe and unambiguously identify nu /sub e/, nu /sub mu / and nu /sub tau / components, this technology allows to explore the full (3*3) mixing matrix. The same class of detector can be proposed for high precision measurements at a neutrino factory. (3 refs).

  6. Argon Welding Inside A Workpiece

    Science.gov (United States)

    Morgan, Gene E.

    1988-01-01

    Canopies convert large hollow workpiece into inert-gas welding chamber. Large manifold serves welding chamber for attachment of liner parts in argon atmosphere. Every crevice, opening and passageway provided with argon-rich environment. Weld defects and oxidation dramatically reduced; also welding time reduced.

  7. Fluoride and Water (For Parents)

    Science.gov (United States)

    ... Story" 5 Things to Know About Zika & Pregnancy Fluoride and Water KidsHealth > For Parents > Fluoride and Water Print A ... thirds of 16- to 19-year-olds continue Fluoride and the Water Supply For more than 60 years, water fluoridation ...

  8. The cariostatic mechanisms of fluoride

    OpenAIRE

    Kata Rošin-Grget; Kristina Peroš; Ivana Šutej; Krešimir Bašić

    2013-01-01

    This article discusses the possible cariostatic mechanisms of the action of fluoride. In the past, fluoride inhibition of caries was ascribed to reduced solubility of enamel due to incorporation of fluoride (F–) into the enamel minerals. The present evidence from clinical and laboratory studies suggests that the caries-preventive mode of action of fluoride is mainly topical. There is convincing evidence that fluoride has a major effect on demineralisation and remineralisation of dental hard t...

  9. Fluoride in diet

    Science.gov (United States)

    ... broken through the gums have changes in the enamel that covers the teeth. Faint white lines or streaks may appear, but ... regarding fluoride intake from reconstituted infant formula and ... Dental Association Council on Scientific Affairs. J Am Dent ...

  10. Fluoride toothpastes and fluoride mouthrinses for home use

    Directory of Open Access Journals (Sweden)

    Andrew Rugg-Gunn

    2013-11-01

    Full Text Available Objective. To provide a brief commentary review of fluoride-containing toothpastes and mouthrinses with emphasis on their use at home. Toothpastes and mouthrinses are just two of many ways of providing fluoride for the prevention of dental caries. The first investigations into incorporating fluoride into toothpastes and mouthrinses were reported in the middle 1940s. Unlike water fluoridation (which is ‘automatic fluoridation’, fluoride-containing toothpastes and fluoride-containing mouthrinses are, primarily, for home use and need to be purchased by the individual. By the 1960s, research indicated that fluoride could be successfully incorporated into toothpastes and clinical trials demonstrated their effectiveness. By the end of the 1970s, almost all toothpastes contained fluoride. The widespread use of fluoride-containing toothpastes is thought to be the main reason for much improved oral health in many countries. Of the many fluoride compounds investigated, sodium fluoride, with a compatible abrasive, is the most popular, although amine fluorides are used widely in Europe. The situation is similar for mouthrinses. Concentrations of fluoride (F, commonly found, are 1500 ppm (1500 μg F/g for toothpastes and 225 ppm (225 μg F/ml for mouthrinse. Several systematic reviews have concluded that fluoride-containing toothpastes and mouthrinses are effective, and that there is added benefit from their use with other fluoride delivery methods such as water fluoridation. Guidelines for the appropriate use of fluoride toothpastes and mouthrinses are available in many countries.Conclusion. Fluoride toothpastes and mouthrinses have been developed and extensive testing has demonstrated that they are effective and their use should be encouraged.

  11. Microwave Argon Plasma Torch

    Science.gov (United States)

    Felizardo, Edgar; Pencheva, Mariana; Benova, Evgenia; Dias, Fransisco; Tatarova, Elena

    2009-10-01

    A theoretical and experimental investigation of a microwave (2.45 GHz) Argon plasma torch driven by a surface wave is presented. The theoretical model couples in a self-consistent way the wave electrodynamics and the electron and heavy particle kinetics. The set of coupled equations includes: Maxwell's equations, the electron Boltzmann equation, including electron-electron collisions, and the particle balance equations for electrons, excited atoms (4s, 4p, 3d, 5s, 5p, 4d, 6s), and atomic (Ar^+) and molecular ions (Ar2^+). The input parameters of the model are: gas pressure (760 Torr), plasma radius (R = 0.75 cm), dielectric permittivity (ɛd = 4.0) and tube thickness (d = 0.15 cm) as well as the measured axial profile of the gas temperature (3500 K - 1500 K). The latter was determined from measurements of the rotational temperature of the OH molecular band in the range 306 - 315 nm. Phase and amplitude sensitive recording provides the data for the axial wavenumber and wave attenuation coefficient. The wavenumber decreases along the generated plasma torch. The electron density (Ne) axial profile as determined from measurements of Hβ Stark broadening is in agreement with the theoretical one.

  12. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  13. Electrical conductivity of compressed argon

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, R. [Univ. Regensburg (Germany); Windl, W.; Collins, L.; Kress, J.; Kwon, I. [Los Alamos National Lab., NM (United States)

    1997-10-01

    The authors report calculations of the electrical conductivity of solid argon as a function of compression within the density functional local density approximation formulation for a norm-conserving pseudopotential using both electron-phonon coupling and molecular dynamics techniques.

  14. Testing a liquid Argon calorimeter

    CERN Multimedia

    1976-01-01

    Physicists from Karlsruhe test a liquid argon calorimeter in the neutral beam b16 at the PS. The calorimeter was meant to supply some neutral particles identification at the Split-Field Magnet Facility for R416.

  15. The Liquid Argon Purity Demonstrator

    CERN Document Server

    Adamowski, M; Dvorak, E; Hahn, A; Jaskierny, W; Johnson, C; Jostlein, H; Kendziora, C; Lockwitz, S; Pahlka, B; Plunkett, R; Pordes, S; Rebel, B; Schmitt, R; Stancari, M; Tope, T; Voirin, E; Yang, T

    2014-01-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  16. Water Fluoridation Statistics - Percent of PWS population receiving fluoridated water

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2000-2014 Water Fluoridation Statistics is a biennial report of the percentage and number of people receiving fluoridated water from 2000 through 2014, originally...

  17. Fluoridated elastomers: in vivo versus in vitro fluoride release

    OpenAIRE

    Tinsley, D.; O'Dwyer, J. J.; Benson, P.E.

    2003-01-01

    OBJECTIVES: To compare (i) the in vivo release of fluoride from fluoridated elastomers to the in vitro release, and (ii) the residual fluoride content of the elastomers after 1 week in the mouth with and without fluoride toothpaste and mouthrinse. DESIGN: A prospective, longitudinal, cross-over study. Subjects and method: Six subjects were recruited by poster to take part in the study. Each subject had one premolar in each quadrant to which a bracket could be fixed and exemplar...

  18. Fluoride retention by kaolin clay

    DEFF Research Database (Denmark)

    Kau, P. M. H.; Smith, D. W.; Binning, Philip John

    1997-01-01

    To evaluate the potential effectiveness of kaolin clay liners in storage of fluoride contaminated waste, an experimental study of the sorption and desorption behaviour of fluoride in kaolin clay was conducted. The degree of fluoride sorption by kaolin was found to depend on solution pH and...

  19. Fluoride Uptake Level of the Enamel by a Fluoride Varnish and a Fluoride Gel (APF)

    OpenAIRE

    Navabi B; Ansari G.; Khan Z; Kheirieh P.; Najafi B.

    2011-01-01

    Statement of Problem: Various forms of fluoride-contained products are used to increase the resistance of the tooth against caries for preventive purposes. Furthermore, studies demonstrated higher fluoride uptake with varnish and gel among the wide range of products.Purpose: This study compared fluoride uptake of Duraflor® varnish (Practicon Dent, USA) with fluoride gel (APF, Sultan®), used on the enamel surface of the intact teeth.Materials and Method: In this experimental in-vitro study, 2...

  20. Fano factor in pure argon

    International Nuclear Information System (INIS)

    The Fano factor for 5.3 MeV alpha particles in pure argon has been measured with a gridded ionization chamber and estimated to be 0.20 (+0.01-0.02). The obtained value is consistent with the theoretical value if the contribution of elastic nuclear collisions to the Fano factor is taken into the consideration. There is no appreciable difference between the values for pure argon and for a gas mixture of Ar (10%)CH4 obtained in the previous measurement. (orig.)

  1. Other Fluoride Products

    Science.gov (United States)

    ... in preventing tooth decay in people of all ages. Use the information listed below to compare the other fluoride products ... even among children younger than 6 years of age. Proper application technique ... cleared for marketing by the Food and Drug Administration (FDA) as ...

  2. Salt fluoridation and oral health

    Directory of Open Access Journals (Sweden)

    Thomas M. Marthaler

    2013-11-01

    Full Text Available The aim of this paper is to make known the potential of fluoridated salt in community oral health programs, particularly in South Eastern Europe. Since 1922, the addition of iodine to salt has been successful in Switzerland. Goiter is virtually extinct. By 1945, the cariesprotective effect of fluorides was well established. Based on the success of water fluoridation, a gynecologist started adding of fluoride to salt. The sale of fluoridated salt began in 1956 in the Swiss Canton of Zurich, and several other cantons followed suit. Studies initiated in the early seventies showed that fluoride, when added to salt, inhibits dental caries. The addition of fluoride to salt for human consumption was officially authorized in 1980-82. In Switzerland 85% of domestic salt consumed is fluoridated and 67% in Germany. Salt fluoridation schemes are reaching more than one hundred million in Mexico, Colombia, Peru and Cuba. The cost of salt fluoridation is very low, within 0.02 and 0.05 € per year and capita. Children and adults of the low socio-economic strata tend to have substantially more untreated caries than higher strata. Salt fluoridation is by far the cheapest method for improving oral health. Conclusions. Salt fluoridation has cariostatic potential like water fluoridation (caries reductions up to 50%. In Europe, meaningful percentages of users have been attained only in Germany (67% and Switzerland (85%. In Latin America, there are more than 100 million users, and several countries have arrived at coverage of 90 to 99%. Salt fluoridation is by far the cheapest method of caries prevention, and billions of people throughout the world could benefit from this method.

  3. Development of an active 238uranium(VI)-fluoride detector chamber for precision experiments in photon-induced fission at the S-DALINAC

    International Nuclear Information System (INIS)

    The polarized injector SPIN at the S-DALINAC provides spin polarized electrons for circularly polarized bremsstrahlung with a high degree of polarization near the endpoint energy of the spectrum, enabling the search for forward-backward asymmetries of the light and heavy fission fragment originating from parity non-conservation in the photon-induced fission process of 238U. An active 238uranium(VI)-fluoride gas target has been developed along the lines of a simple Frisch grid ionization chamber to raise the luminosity and to study the properties of an 238uranium(VI)-fluoride/argon gas mixture. The active 238uranium(VI)-fluoride gas target has been filled with argon and 238uranium(VI)-fluoride using mass flow controllers. At different settings data has been acquired and interpreted. Instantly after filling the chamber with some 238uranium(VI)-fluoride the anode and cathode signal are severely lowered and gain only slowly. Apparently the 238uranium(VI)-fluoride acts as a very efficient electron collector because of its complexity and the high amount of fluorine and its electronegativity. Over time, the amount of gaseous 238uranium(VI)-fluoride is reduced and different processes are possible to explain this effect. In the present configuration of the active 238uranium(VI)-fluoride gas target no sound quantitative information on the properties of an 238uranium(VI)-fluoride/argon gas mixture can be given. Raising the luminosity for precision experiments in photon-induced fission at the S-DALINAC with an active 238uranium(VI)-fluoride gas target appears to be impossible.

  4. Water fluoridation and oral health

    Directory of Open Access Journals (Sweden)

    Máiréad Antoinette Harding

    2013-11-01

    Full Text Available Water fluoridation, is the controlled addition of fluoride to the water supply, with the aim of reducing the prevalence of dental caries. Current estimates suggest that approximately 370 million people in 27 countries consume fluoridated water, with an additional 50 million consuming water in which fluoride is naturally occurring. A pre-eruptive effect of fluoride exists in reducing caries levels in pit and fissure surfaces of permanent teeth and fluoride concentrated in plaque and saliva inhibits the demineralisation of sound enamel and enhances the remineralisation of demineralised enamel. A large number of studies conducted worldwide demonstrate the effectiveness of water fluoridation. Objections to water fluoridation have been raised since its inception and centre mainly on safety and autonomy. Systematic reviews of the safety and efficacy of water fluoridation attest to its safety and efficacy; dental fluorosis identified as the only adverse outcome. Conclusion: Water fluoridation is an effective safe means of preventing dental caries, reaching all populations, irrespective of the presence of other dental services. Regular monitoring of dental caries and fluorosis is essential particularly with the lifelong challenge which dental caries presents.

  5. Health Effects Associated with Water Fluoridation.

    Science.gov (United States)

    Richmond, Virginia L.

    1979-01-01

    Discussion is presented concerning fluoridation of water supplies. Correlation between fluoride in drinking water and improved dental health is reviewed. Relationship is expressed between fluoridation and reduced tooth decay. Use of fluoride in treating skeletal disorders is discussed. Author advocates fluoridating water supplies. (SA)

  6. Fluoride and dental caries

    OpenAIRE

    Camilleri, George E.

    1998-01-01

    Fluorine was probably discovered by the chemist Scheele in 1771, and eventually isolated in 1886 by Moissan. Its presence in bones and teeth was initially disputed but eventually confirmed in the middle of the eighteenth century. In this article the author discusses the few epidemiological studies which confirm the relationship between fluoride concentration in drinking water, mottled enamel and the incidence of dental caries and also describes the Maltese scene in regards the caries level in...

  7. Fluoride in dental erosion

    OpenAIRE

    Magalhães, A C; Wiegand, A.; Rios, D.; Buzalaf, M.A.R.; Lussi, A.

    2011-01-01

    Dental erosion develops through chronic exposure to extrinsic/intrinsic acids with a low pH. Enamel erosion is characterized by a centripetal dissolution leaving a small demineralized zone behind. In contrast, erosive demineralization in dentin is more complex as the acid-induced mineral dissolution leads to the exposure of collagenous organic matrix, which hampers ion diffusion and, thus, reduces further progression of the lesion. Topical fluoridation inducing the formation of a protective l...

  8. Development of an active {sup 238}uranium(VI)-fluoride detector chamber for precision experiments in photon-induced fission at the S-DALINAC; Entwicklung einer aktiven {sup 238}Uran(VI)-fluorid-Detektor-Kammer fuer Praezisionsexperimente in der photoneninduzierten Spaltung am S-DALINAC

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, Christian

    2013-07-22

    The polarized injector SPIN at the S-DALINAC provides spin polarized electrons for circularly polarized bremsstrahlung with a high degree of polarization near the endpoint energy of the spectrum, enabling the search for forward-backward asymmetries of the light and heavy fission fragment originating from parity non-conservation in the photon-induced fission process of {sup 238}U. An active {sup 238}uranium(VI)-fluoride gas target has been developed along the lines of a simple Frisch grid ionization chamber to raise the luminosity and to study the properties of an {sup 238}uranium(VI)-fluoride/argon gas mixture. The active {sup 238}uranium(VI)-fluoride gas target has been filled with argon and {sup 238}uranium(VI)-fluoride using mass flow controllers. At different settings data has been acquired and interpreted. Instantly after filling the chamber with some {sup 238}uranium(VI)-fluoride the anode and cathode signal are severely lowered and gain only slowly. Apparently the {sup 238}uranium(VI)-fluoride acts as a very efficient electron collector because of its complexity and the high amount of fluorine and its electronegativity. Over time, the amount of gaseous {sup 238}uranium(VI)-fluoride is reduced and different processes are possible to explain this effect. In the present configuration of the active {sup 238}uranium(VI)-fluoride gas target no sound quantitative information on the properties of an {sup 238}uranium(VI)-fluoride/argon gas mixture can be given. Raising the luminosity for precision experiments in photon-induced fission at the S-DALINAC with an active {sup 238}uranium(VI)-fluoride gas target appears to be impossible.

  9. Strontium-90 fluoride data sheet

    International Nuclear Information System (INIS)

    This report is a compilation of available data and appropriate literature references on the properties of strontium-90 fluoride and nonradioactive strontium fluoride. The objective of the document is to compile in a single source pertinent data to assist potential users in the development, licensing, and use of 90SrF2-fueled radioisotope heat sources for terrestrial power conversion and thermal applications. The report is an update of the Strontium-90 Fluoride Data Sheet (BNWL-2284) originally issued in April 1977

  10. Fluoride remediation using floating macrophytes

    OpenAIRE

    Naba Kumar Mondal; Ria Bhaumik; Uttiya Dey; Kartick Chandra Pal; Chittaranjan Das; Anindita Maitra; Jayanta Kumar Datta

    2014-01-01

    Six aquatic macrophytes, such as Pistia stratiotes, Ceratophyllum demersum, Nymphoides indica, Lemna major, Azolla pinnata,and Eichhornia crassipes were considered for remove fluoride from aqueous solution. Five different concentrations (10, 30, 50, and 100 ppm) of fluoride solution were taken in 1 L plastic container. Fixed weight (20 g) of macrophytes along with 500 ml fluoride solution was taken in each plastic container for 72 hours observation. Results demonstrated all the macrophytes sh...

  11. Fluoride Rinses, Gels and Foams

    DEFF Research Database (Denmark)

    Twetman, Svante; Keller, Mette K

    2016-01-01

    electronic search for literature published in English between 2003 and 2014. The included papers were assessed for their risk of bias and the results were narratively synthesized due to study heterogeneity. The quality of evidence was expressed according to GRADE. RESULTS: A total of 19 papers were included......, previously established in systematic reviews. The lack of clinical trials free from bias is, however, still a concern, especially for fluoride mouth rinses and fluoride foam. There is also a scientific knowledge gap on the benefit and optimal use of these fluoride supplements in combination with daily tooth...... brushing with fluoride toothpaste....

  12. Binocular indirect argon laser photocoagulator.

    OpenAIRE

    Mizuno, K

    1981-01-01

    The binocular indirect argon laser photocoagulator was newly designed to enable visualisation of the entire fundus during panretinal laser photocoagulation and to treat retinal tears immediately after buckling procedures of the sclera. The lamp housing of the binocular ophthalmoscope was remodelled and adjusted so that the laser beam and illuminating light are coaxial after leaving the ophthalmoscope. The blocking filter was permanently fixed in the eye-pieces to lighten the weight of the oph...

  13. Liquid Argon Barrel Cryostat Arrived

    CERN Multimedia

    Pailler, P

    Last week the first of three cryostats for the ATLAS liquid argon calorimeter arrived at CERN. It had travelled for 46 days over several thousand kilometers from Japan to CERN. During three years it has been fabricated by Kawasaki Heavy Industries Ltd. at Harima, close to Kobe, under contract from Brookhaven National Laboratory (BNL) of the U.S.. This cryostat consists of two concentric cylinders made of aluminium: the outer vacuum vessel with a diameter of 5.5 m and a length of 7 m, and the inner cold vessel which will contain the electromagnetic barrel calorimeter immersed in liquid argon. The total weight will be 270 tons including the detectors and the liquid argon. The cryostat is now located in building 180 where it will be equipped with 64 feed-throughs which serve for the passage of 122,880 electrical lines which will carry the signals of the calorimeter. After integration of the calorimeter, the solenoidal magnet of ATLAS will be integrated in the vacuum vessel. A final cold test of the cryostat inc...

  14. Private Well Water and Fluoride

    Science.gov (United States)

    ... it is the responsibility of the homeowner to know and understand the quality of the water from their well. The U.S. ... or area. Additional information on testing well water quality in private wells ... do I need to know about fluoride and groundwater from a well? Fluoride ...

  15. The scintillation of liquid argon

    CERN Document Server

    Heindl, T; Hofmann, M; Krücken, R; Oberauer, L; Potzel, W; Wieser, J; Ulrich, A

    2015-01-01

    A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd excimer continuum. Various additional emission features were found. The time structure of the light emission has been measured for a set of well defined wavelength positions. The results help to interpret literature data in the context of liquid rare gas detectors in which the wavelength information is lost due to the use of wavelength shifters.

  16. Urinary Fluoride Concentration in Children with Disabilities Following Long-Term Fluoride Tablet Ingestion

    Science.gov (United States)

    Liu, Hsiu-Yueh; Chen, Jung-Ren; Hung, Hsin-Chia; Hsiao, Szu-Yu; Huang, Shun-Te; Chen, Hong-Sen

    2011-01-01

    Urine is the most commonly utilized biomarker for fluoride excretion in public health and epidemiological studies. Approximately 30-50% of fluoride is excreted from urine in children. Urinary fluoride excretion reflects the total fluoride intake from multiple sources. After administering fluoride tablets to children with disabilities, urinary…

  17. 49 CFR 173.163 - Hydrogen fluoride.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned...

  18. Molten fluoride fuel salt chemistry

    International Nuclear Information System (INIS)

    The chemistry of molten fluorides is traced from their development as fuels in the Molten Salt Reactor Experiment with important factors in their selection being discussed. Key chemical characteristics such as solubility, redox behavior, and chemical activity are explained as they relate to the behavior of molten fluoride fuel systems. Fission product behavior is described along with processing experience. Development requirements for fitting the current state of the chemistry to modern nuclear fuel system are described. It is concluded that while much is known about molten fluoride behavior, processing and recycle of the fuel components is a necessary factor if future systems are to be established

  19. Fluoride Concentration in Dentin of Exfoliated Primary Teeth as a Biomarker for Cumulative Fluoride Exposure

    OpenAIRE

    dela Cruz, G.G.; Rozier, R.G.; Bawden, J.W.

    2008-01-01

    A biomarker for lifetime fluoride exposure would facilitate population-based research and policy making but currently does not exist. This study examined the suitability of primary tooth dentin as a biomarker by comparing dentin fluoride concentration and fluoride exposures. Ninety-nine children's exfoliated primary teeth were collected from 2 fluoridated and 2 fluoride-deficient communities in North Carolina. Coronal dentin was isolated by microdissection and fluoride concentration assayed u...

  20. Fluoride retention in saliva and in dental biofilm after different home-use fluoride treatments

    OpenAIRE

    Souza, Daniela Correia Cavalcante; Marisa MALTZ; Lina Naomi HASHIZUME

    2014-01-01

    This single-blind, randomized, crossover study aimed at assessing the long-term fluoride concentrations in saliva and in dental biofilm after different home-use fluoride treatments. The study volunteers (n = 38) were residents of an area with fluoridated drinking water. They were administered four treatments, each of which lasted for one week: twice-daily placebo dentifrice, twice-daily fluoride dentifrice, twice-daily fluoride dentifrice and once-daily fluoride mouthrinse, and thrice-daily f...

  1. URINARY FLUORIDE OUTPUT IN CHILDREN FOLLOWING THE USE OF A DUAL-FLUORIDE VARNISH FORMULATION

    OpenAIRE

    Kelly Polido Kaneshiro Olympio; Vanessa Eid da Silva Cardoso; Maria Fernanda Borro Bijella; Juliano Pelim Pessan; Alberto Carlos Botazzo Delbem; Marília Afonso Rabelo Buzalaf

    2009-01-01

    OBJECTIVE: This study evaluated the bioavailability of fluoride after topical application of a dual-fluoride varnish commercially available in Brazil, when compared to DuraphatTM. MATERIAL AND METHODS: The urinary fluoride output was evaluated in seven 5-year-old children after application of the fluoride varnishes, in two different phases. In the first phase (I), children received topical application of the fluoride varnish Duofluorid XII (2.92% fluorine, calcium fluoride + 2.71% fluorine, s...

  2. Fluoride glass: Crystallization, surface tension

    Science.gov (United States)

    Doremus, R. H.

    1988-01-01

    Fluoride glass was levitated acoustically in the ACES apparatus on STS-11, and the recovered sample had a different microstructure from samples cooled in a container. Further experiments on levitated samples of fluoride glass are proposed. These include nucleation, crystallization, melting observations, measurement of surface tension of molten glass, and observation of bubbles in the glass. Ground experiments are required on sample preparation, outgassing, and surface reactions. The results should help in the development and evaluation of containerless processing, especially of glass, in the development of a contaminent-free method of measuring surface tensions of melts, in extending knowledge of gas and bubble behavior in fluoride glasses, and in increasing insight into the processing and properties of fluoride glasses.

  3. Chronic Fluoride Toxicity: Dental Fluorosis

    OpenAIRE

    DenBesten, Pamela; Li, Wu

    2011-01-01

    Dental fluorosis occurs as a result of excess fluoride ingestion during tooth formation. Enamel fluorosis and primary dentin fluorosis can only occur when teeth are forming, and therefore fluoride exposure (as it relates to dental fluorosis) occurs during childhood. In the permanent dentition, this would begin with the lower incisors, which complete mineralization at approximately 2–3 years of age, and end after mineralization of the third molars. The white opaque appearance of fluorosed enam...

  4. Method of aluminium fluoride manufacture

    International Nuclear Information System (INIS)

    The manufacture of aluminium fluoride is based on waste processing in uranium hexafluoride conversion to uranium oxides within the fuel cycle. The conversion is the stoichiometric conversion of uranium hexafluoride with aluminium nitrate to uranyl nitrate. This is extracted from the water phase by phosphoric acid trialkyl ester to an organic solvent and further processed. The discharge water phase is solidified by evaporation to solid aluminium fluoride and nitric acid. (M.S.)

  5. Transition probabilities for argon I

    International Nuclear Information System (INIS)

    Transition probabilities for ArI lines have been calculated on the basis of the (j,k)-coupling scheme for more than 16000 spectral lines belonging to the transition arrays 4s-np (n=4 to n=9), 5s-np (n=5 to n=9), 6s-np (n=6 to n=9), 7s-np (n=8 to n=9), 4p-ns (n=5 to n=10), 5p-ns (n=6 to n=9), 6p-ns (n=7 to n=8), 4p-nd (n=3 to n=9), 5p-nd (n=4 to n=9), 3d-np (n=5 to n=9), 4d-np (n=6 to n=9), 5d-np (n=7 to n=9), 3d-nf (n=4 to n=9), 4d-nf (n=4 to n=9), 5d-nf (n=5 to n=9), 4f-nd (n=5 to n=9) 5f-nd (n=6 to n=9), 4f-ng (n=5 to n=9), 5f-ng (n=6 to n=9). Inso far as values by other authors exist, comparison is made with these values. It turns out that the results obtained in (j,k)-coupling are close to those obtained in intermediate coupling except for intercombination lines. For high principal and/or orbital quantum numbers the transition probabilities for a multiplet approach those of the corresponding transitions in atomic hydrogen. The calculated values are applied to construct a simplified argon-atom model, which reflects the real transition properties and which allows simplified but realistic non-equilibrium calculations for argon plasmas which deviate from local thermodynamic equilibrium (LTE)

  6. The fluoride content of bottled drinking waters.

    Science.gov (United States)

    Toumba, K J; Levy, S; Curzon, M E

    1994-04-01

    Sales of bottled drinking waters in the United Kingdom have tripled over the last 5 years. The fluoride content of 12 bottled waters purchased from two Leeds supermarkets was determined by both the direct and acid diffusion methods and found to vary from 0.10-0.80 mg/l fluoride (ie ppm fluoride). This article shows that bottled drinking waters contain differing concentrations of fluoride. There is no apparent difference between the direct and acid diffusion methods for the determination of fluoride concentrations of drinking waters. The manufacturers' labelling of fluoride concentrations are mainly inaccurate. Dentists should be aware of the fluoride concentrations of the drinking water of their child patients, be they municipal or bottled drinking water, when prescribing fluoride supplements. Also, some parents are using bottled waters to prepare baby milk formulations which themselves may contain high levels of fluoride and subject their children to the risk of dental fluorosis. PMID:8186036

  7. Corrosion behavior of Hastelloy-N alloys in molten salt fluoride in Ar gas or in air

    International Nuclear Information System (INIS)

    The effects of air on the corrosion of Hastelloy-N alloys in molten salt coolant containing fission product elements were investigated to determine the safety of structural materials in high-temperature reactors cooled with fluoride salt. Corrosion tests of Hastelloy-N in the molten fluoride salt FLiNaK in an alumina crucible and a graphite crucible under argon gas or air were performed at 773–923 K for 100 h. The depth of corrosive attack, as well as the extent of chromium and molybdenum depletion, increased with increasing temperature. The extent of Hastelloy-N corrosion in molten salt under air was significantly greater than under argon gas. The effect of adding the impurity cesium iodide to molten salt containing nuclear waste fuel on the corrosion behavior was negligible. (author)

  8. Argon-39 Background in DUNE Photon Detectors

    Science.gov (United States)

    Sinev, Gleb; DUNE Collaboration

    2016-03-01

    The Deep Underground Neutrino Experiment (DUNE) is a 40-kt liquid argon detector that will be constructed 5000 ft underground in the Sanford Underground Research Facility in order to study neutrino and proton decay physics. Instrumenting liquid argon with photon detectors to record scintillation in addition to the ionization signal can significantly improve time and energy resolution of the experiment. Argon produces light with wavelength of 128 nm. The reference design for the photon detectors includes acrylic bars covered in wavelength shifter, where the scintillation light can be captured and reemitted with longer wavelengths, then detected using silicon photomultipliers. Radiological backgrounds may noticeably deteriorate the photon detection system performance, especially for low-energy interactions. A particularly important background comes from argon-39 decays, because argon-39 is present in natural argon that will be used in DUNE and the background rate increases with the size of the experiment. The effect of the argon-39 background has been studied and is presented in this talk.

  9. Emissive spectra of shock-heated argon

    International Nuclear Information System (INIS)

    To study the radiant properties of argon under weak shock compression, an aluminum target filled with gaseous argon at ambient states was impacted by a tungsten alloy projectile which was launched from a two-stage light gun to 2.00 km/s. The radiant signals of single shock-compressed argon were recorded by a six-channel pyrometer and oscilloscopes, which varied with time linearly for the five channels from 405 nm to 700 nm and exponentially for the channel 800 nm, and the corresponding velocity of shock wave was determined to be 4.10 ± 0.09 km/s. By the present experiment, it has been shown that the absorbability of the shock-heated argon is low for visual light and the optical depths of argon gas turn from thin to thick as wavelengths gradually increase. The time-resolved spectra in the rising-front of the radiant signal in the re-shocked argon were recorded by means of an OMA, and strong emissive spectrum bands near 450 nm light-wave length but no linear spectrum were found. The emissive spectrum properties of shock-compression argon were qualitatively explained by the state parameters and ionization degree

  10. Dynamics of Fluoride Bioavailability in the Biofilms of Different Oral Surfaces after Amine Fluoride and Sodium Fluoride Application

    OpenAIRE

    Naumova, Ella A; Christoph Dickten; Rico Jung; Florian Krauss; Henrik Rübesamen; Katharina Schmütsch; Tudor Sandulescu; Stefan Zimmer; Arnold, Wolfgang H.

    2016-01-01

    It was the aim of this study to investigate differences in fluoride bioavailability in different oral areas after the application of amine fluoride (AmF) and sodium fluoride (NaF). The null hypothesis suggested no differences in the fluoride bioavailability. The tongue coating was removed and biofilm samples from the palate, oral floor and cheeks were collected. All subjects brushed their teeth with toothpaste containing AmF or NaF. Specimens were collected before, as well as immediately afte...

  11. Industrial fluoride pollution. Chronic fluoride poisoning in Cornwall Island cattle.

    Science.gov (United States)

    Krook, L; Maylin, G A

    1979-04-01

    An aluminum plant on the south bank of the St. Lawrence river, southwest of Cornwall Island, Ontario, Canada, has emitted 0.816 metric tons of fluoride daily since 1973; considerably higher amounts were emitted from 1959 to 1973. The plant has been designated as the "major source of fluoride emissions impacting on Cornwall Island." Chronic fluoride poisoning in Cornwall island cattle was manifested clinically by stunted growth and dental fluorosis to a degree of severe interference with drinking and mastication. Cows died at or were slaughtered after the third pregnancy. The deterioration of cows did not allow further pregnancies. Fluoride concentrations in ash of biopsied coccygeal vertebrae increased significantly with age and were dependent on distance from and direction to the aluminum plant. Fluoride in bone ash of a 7-month old-fetus exceeded 500 ppm; fluoride thus was passed transplacentally. Analyses of fluoride in ash of bones obtained at necropsy of cattle from 4 months of age to 4 to 5 years of age showed increased amounts with age. Cancellous bone retained far higher amounts than cortical bone, a reflection of the normally higher metabolic rate of cancellous bone. Concentrations exceeding 10,000 ppm fluoride were recorded in cancellous bone of a 4-to 5-year-old cow. The target cells for fluoride in chronic fluorosis were shown to be the ameloblasts, the dental pulp cells and the odontoblasts and, in bone, primarily the resorbing osteocytes and also the osteoblasts. Atrophy and necrosis of the ameloblasts were responsible for enamel defects. The existing enamel showed brown discoloration from fluoride deposits. The pulp cells underwent fibrous and osseous metaplasia and necrosis of the ectopic bone occurred. The odontoblasts were atrophic and the dentin showed brown discoloration. The resorbing osteocytes were inactive and osteosclerosis resulted. This was especially pronounced in areas of normally great apposition, i.e. in the metaphyses. The epiphyseal

  12. Fluoridering af drikkevandet i Danmark?

    DEFF Research Database (Denmark)

    Arvin, Erik; Spliid, Henrik; Bruvo, M.; Bardow, A.; Ekstrand, K.

    2010-01-01

    Første gang sammenhængen mellem caries (huller i tænderne) og fluoridindholdet i drikkevand blev diskuteret i vandværkskredse i Danmark var ved årsmødet i 1958. Her blev det oplyst, at fluorid i drikkevand beskytter mod caries, men man konstaterede også, at der nok ikke var stemning for fluorid......-tilsætning til drikkevandet (fluoridering). Siden da er emnet ikke taget op. Formålet med dette indlæg er at besvare spørgsmålene: 1. Er der behov for fluoridering af drikkevandet i Danmark? 2. Er der alternativer? Hvordan påvirker blødgøring af vand og andre vandbehandlingsmetoder dental caries hos børn og unge......? Som baggrund herfor vil vi redegøre for resultaterne af et netop afsluttet studium af sammenhængen mellem caries og drikkevandets sammensætning, specielt m.h.t. luoridindholdet og vandets calciumindhold (hårdhed). Undersøgelsen bekræfter, at fluorid i drikkevand i væsentlig grad beskytter mod caries...

  13. Argon plasma irradiation of polypropylene

    International Nuclear Information System (INIS)

    Polypropylene samples were exposed to argon plasma discharge and the changes of the PP surface properties were studied by different methods. Surface wettability was derived from contact angle measured by standard goniometry and chemical structure of the plasma modified PP was studied using X-ray photoelectron spectroscopy (XPS) and by Rutherford backscattering spectroscopy (RBS), surface morphology and roughness of samples using AFM. Zeta potential of pristine and modified PP was determined with the SurPASS. The presence of incorporated oxygen in the PP surface layer, about 60 nm thick, was observed in RBS spectra. Oxygen concentration is a decreasing function of the depth. With progressing aging time the oxygen concentration on the PP surface decreases. Plasma treatment results in a rapid decrease of the contact angle, which increases again with increasing aging time. In XPS measurement the oxygen containing structures, created by the plasma treatment, were found on the very surface of the modified PP and the zeta potential being changed too. The significant difference in zeta potential between pristine and plasma treated PP clearly indicates that the plasma treatment leads to a more hydrophilic PP surface.

  14. Acute toxicity of uranium hexafluoride, uranyl fluoride and hydrogen fluoride

    International Nuclear Information System (INIS)

    Uranium hexafluoride (UF6) released into the atmosphere will react rapidly with moisture in the air to form the hydrolysis products uranyl fluoride (UO2F2) and hydrogen fluoride (HF). Uranium compounds such as UF6 and UO2F2 exhibit both chemical toxicity and radiological effects, while HF exhibits only chemical toxicity. This paper describes the development of a methodology for assessing the human health consequences of a known acute exposure to a mixture of UF6, UO2F2, and HF. 4 refs., 2 figs., 5 tabs

  15. Status and perspecitves of liquid argon calorimeters

    International Nuclear Information System (INIS)

    The status of liquid argon calorimeters is reviewed, and experience obtained with these devices is described. Future perspectives of the liquid ionization chamber technique in calorimetry are also discussed. (orig.)

  16. Clinical periodontics with the argon laser

    Science.gov (United States)

    Finkbeiner, R. L.

    1995-04-01

    The argon laser has proven to be a valuable tool for the thermodynamic debridement of the periodontal lesion, incisions and tissue fusion. Illustrations of clinical applications and discussion of laser parameters will be provided.

  17. Liquid argon neutrals detector (LAND) for PEP

    International Nuclear Information System (INIS)

    The physical effects limiting the gamma energy resolution of a liquid argon calorimeter without passive converter plates is discussed. An example of such a detector based on the General User's Magnet designed at this Summer Study is given

  18. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  19. 21 CFR 868.1075 - Argon gas analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon gas analyzer. 868.1075 Section 868.1075 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1075 Argon gas analyzer. (a) Identification. An argon gas analyzer is a device intended to measure the concentration of argon in a gas mixture to aid...

  20. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  1. Measurements on scintillation light from liquid argon

    International Nuclear Information System (INIS)

    It is shown that an argon calorimeter can operate as a scintillation detector, provided that xenon is added. With the addition of 170 ppm xenon a light yield of 70% has been obtained. In addition the light yield is determined under influence of an electric field, from differently ionising particles and by the use of aluminium mirrors acting as light guides. Finally first measurements with a photomultiplier working at liquid argon temperatures are reported. (orig.)

  2. IMPACT OF FLUORIDE ON DENTAL HEALTH QUALITY

    OpenAIRE

    Medjedovic, Eida; Medjedovic, Senad; Deljo, Dervis; Sukalo, Aziz

    2015-01-01

    Introduction: Fluoride is natural element that strengthens teeth and prevents their decay. Experts believe that the best way to prevent cavities is the use of fluoride from multiple sources. Studies even show that in some cases, fluoride can stop already started damage of the teeth. In children younger than 6 years fluoride is incorporated into the enamel of permanent teeth, making the teeth more resistant to the action of bacterial and acids in food. Goal: The aim of this study is to determi...

  3. Alimentary fluoride intake in preschool children

    OpenAIRE

    Lencova Erika; Ivancakova Romana; Oganessian Edgar; Broukal Zdenek

    2011-01-01

    Abstract Background The knowledge of background alimentary fluoride intake in preschool children is of utmost importance for introducing optimal and safe caries preventive measures for both individuals and communities. The aim of this study was to assess the daily fluoride intake analyzing duplicate samples of food and beverages. An attempt was made to calculate the daily intake of fluoride from food and swallowed toothpaste. Methods Daily alimentary fluoride intake was measured in a group of...

  4. Molten fluorides for nuclear applications

    Directory of Open Access Journals (Sweden)

    Sylvie. Delpech

    2010-12-01

    Full Text Available The importance of pyrochemistry is being increasingly acknowledged and becomes unavoidable in the nuclear field. Molten salts may be used for fuel processing and spent fuel recycling, for heat transfer, as a homogeneous fuel and as a breeder material in fusion systems. Fluorides that are stable at high temperature and under high neutron flux are especially promising. Analysis of several field cases reveals that corrosion in molten fluorides is essentially due to the oxidation of metals by uranium fluoride and/or oxidizing impurities. The thermodynamics of this process are discussed with an emphasis on understanding the mass transfer in the systems, selecting appropriate metallic materials and designing effective purification methods.

  5. Fluoride: its role in dentistry

    Directory of Open Access Journals (Sweden)

    Livia Maria Andaló Tenuta

    2010-01-01

    Full Text Available In spite of decades of research on fluoride and the recognition of its role as the cornerstone of dental caries reduction in the last fifty years, questions still arise on its use at community, self-applied and professional application levels. Which method of fluoride delivery should be used? How and when should it be used? How can its benefits be maximized and still reduce the risks associated with its use? These are only some of the challenging questions facing us daily. The aim of this paper is to present scientific background to understand the importance of each method of fluoride use considering the current caries epidemiological scenario, and to discuss how individual or combined methods can be used based on the best evidence available.

  6. Fluoride Uptake Level of the Enamel by a Fluoride Varnish and a Fluoride Gel (APF

    Directory of Open Access Journals (Sweden)

    Navabi B.

    2011-07-01

    Full Text Available Statement of Problem: Various forms of fluoride-contained products are used to increase the resistance of the tooth against caries for preventive purposes. Furthermore, studies demonstrated higher fluoride uptake with varnish and gel among the wide range of products.Purpose: This study compared fluoride uptake of Duraflor® varnish (Practicon Dent, USA with fluoride gel (APF, Sultan®, used on the enamel surface of the intact teeth.Materials and Method: In this experimental in-vitro study, 20 intact pre-molar teeth extracted for orthodontic purposes were randomly assigned to two groups of 10 teeth. The teeth were sectioned into two mesial and distal halves as the control and experimental sides. Defined semi-circular areas on the enamel surface of the experimental halves were treated with gel or varnish for 1 hour. The sample halves were stored in artificial saliva for 24 hours at 37°c, etched for 30 seconds by 0.5 M perchloric acid, and washed by 0.2 m KOH after each etching process. Biopsies of the samples were obtained by Acid Etch Enamel Biopsy technique and the fluoride and calcium concentrations were calculated by potentiometer and spectrophotometer, respectively. Kolmogorov-smirnov, Paired t-test and Student t- test were used for statistical analyses.Results: The results demonstrated an increase in the enamel fluoride content after exposure of the teeth to both Duraflor® varnish and APF gel (Sultan®. The results of the paired t-test revealed significant differences between the experimental and control halves in both groups (varnish: p =0.002, gel: p =0.039. The fluoride uptake value in varnish and gel groups was 2069.78 ppm and 1050.99 ppm, respectively. The student t-test showed a statistically significant difference ( p =0.01.Conclusion: Both APF gel and Duraflor® varnish increased the fluoride content of the tooth enamel after application, although Duraflor® varnish had a higher fluoride uptake level than APF gel.

  7. Effect of fluoride on Treponema denticola.

    OpenAIRE

    Hughes, C A; Yotis, W W

    1986-01-01

    The effect of fluoride on the growth of Treponema denticola was studied. Fluoride, at a concentration of 20 micrograms/ml, was found to suppress the growth of all three strains tested. Growth was completely inhibited by 40 micrograms of fluoride per ml.

  8. Fluoride in African groundwater: Occurrence and mitigation

    NARCIS (Netherlands)

    Vasak, S.; Griffioen, J.; Feenstra, L.

    2010-01-01

    Fluoride in groundwater has both natural and anthropogenic sources. Fluoride bearing minerals, volcanic gases and various industrial and agricultural activities can contribute to high concentrations. High intake of fluoride from drinking water is the main cause of fluorosis and may lead to many othe

  9. Ultraviolet transmission of fluoride glasses

    International Nuclear Information System (INIS)

    In recent years there has been a great deal of interest in infrared-transmitting materials. However, with the commercial interest in excimer lasers and collection and utilization of solar energy, there is an increased interest in UV transmitting materials. In the absence of impurities, it has been observed that fluoride glasses are potentially very good UV transmitters. This paper reports the effects of intense UV radiation on fluoride glasses of various composition and on the status of dopants in those glasses. Possible limitations for these materials as UV transmission media are discussed

  10. Potassium-argon/argon-40-argon-39 geochronology of Cenozoic alkali basalts from the South China Sea

    Institute of Scientific and Technical Information of China (English)

    YAN Quanshu; SHI Xuefa; YANG Yaomin; WANG Kunshan

    2008-01-01

    Based on the isotopic chronologic results of Cenozoic alkali basalts from the South China Sea,the characteristics of volcanic activi-ty of the South China Sea after spreading were studied.The potassium - argon ages of eight alkali basalt samples from the South China Sea,and the argon - argon ages of two samples among them are reported.Apparent ages of the whole rock are 3.80 to 7.91 Ma with an average value of 5.43 Ma (potassium- argon,whole rock),and there is little difference among samples at the same location,e.g.,4.76~5.78 Ma for location S04-12.The argon - argon ages for the two samples are 6.06 and 4.71 Ma,which lie within the age scope of potassium - argon method.The dating results indicate that rock-forming age is from late Miocene to Pli-ocene,which is consistent with erupting event for alkali basalts from adjacent regions of the South China Sea.Volcanic activities occur after the cessation of spreading of the South China Sea,which are controlled by lithospheric fault and the spreading center formed during the spreading period of the South China Sea.These dating results,combined with geochemical characteristics of these basalts,the published chronological data for the South China Sea and its adjacent regions,and the updated geophysical data near Hainan Island,suggest that after the cessation of spreading of the South China Sea,there occur widely distributing magmatic activities which primarily is alkali basalt,and the volcanic activity continues to Quaternary.The activity may be relative to Hainan mantle plume originated from core/mantle boundary.

  11. Argon Collection And Purification For Proliferation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Achey, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event was a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.

  12. Kinetic and experimental study of argon and argon--nitrogen mixtures excited by fission fragments

    International Nuclear Information System (INIS)

    Optical emission from argon and argon-nitrogen mixtures excited by fission fragments are studied in an effort to better understand the fission fragment energy deposition into the gas. A model of the energy flow in the gas is developed and compared with the experimental results

  13. Amphiphobicity of polyvinylidene fluoride porous films after atmospheric pressure plasma intermittent etching

    International Nuclear Information System (INIS)

    This study modified the surface of polyvinylidene fluoride (PVDF) films and characterized their surface physicochemical properties. The main aim of this study was to examine how to provide the surface with a specific property, e.g., not only hydrophobic but also oleophobic (amphiphobicity) after argon atmospheric pressure plasma (APP) treatment. The surface free energy calculated using the Owens-Wendt (OW) method decreased significantly while showing a very small value of the polar component. Scanning electron microscopy indicated that a small amount of hydrophilic solid spines and many superamphiphobic uniform micro air pockets formed in the plasma-modified PVDF film, which made it amphiphobic but not superamphiphobic.

  14. Fluoride remediation using floating macrophytes

    Directory of Open Access Journals (Sweden)

    Naba Kumar Mondal

    2014-04-01

    Full Text Available Six aquatic macrophytes, such as Pistia stratiotes, Ceratophyllum demersum, Nymphoides indica, Lemna major, Azolla pinnata,and Eichhornia crassipes were considered for remove fluoride from aqueous solution. Five different concentrations (10, 30, 50, and 100 ppm of fluoride solution were taken in 1 L plastic container. Fixed weight (20 g of macrophytes along with 500 ml fluoride solution was taken in each plastic container for 72 hours observation. Results demonstrated all the macrophytes show highest fluoride removal during 24 h to 48 h, but after 72 h their efficiency reduced drastically. The species N. indica showed better removal efficiency than other experimental macrophytes. In general, pigment measurement data indicated higher concentration at 72 h. However, Pistia sp. showed higher concentration of pigmentation at intermediate time interval (48 h. Higher level of dry weight to fresh weight ratio was recorded for L. major and A. pinnata at all concentrations, excepting at 10 ppm. In addition, all macrophytes showed lower RGR at higher concentration. Isotherm study indicated that macrophyte C. demersum is a good fitted with Freundlich and Langmuir isotherm whereas L. major with Langmuir isotherm during 24 hours.

  15. Argon activation analysis, application to dating by the potassium-argon method

    International Nuclear Information System (INIS)

    Activation analysis using radiogenic argon-40 has been applied to rock-dating by the K-Ar method. The argon is extracted from the sample, purified, activated to saturation in a flux of 2 X 1013 neutrons/cm2 sec-1 and measured by gamma spectroscopy. The sensitivity obtained is such that it is possible to measure amounts of argon corresponding to age of a few thousand years only. However since it has not been possible to measure the amount of pollution of radiogenic argon by atmospheric argon with any accuracy, the measurable age limit is in fact of the order of MY. The method has been applied to basalts from the Mont-Dore region. The results obtained are in fairly good agreement with geological, stratigraphic and paleomagnetic data. (author)

  16. Global affordability of fluoride toothpaste

    Directory of Open Access Journals (Sweden)

    Holmgren Christopher J

    2008-06-01

    Full Text Available Abstract Objective Dental caries remains the most common disease worldwide and the use of fluoride toothpaste is a most effective preventive public health measure to prevent it. Changes in diets following globalization contribute to the development of dental caries in emerging economies. The aim of this paper is to compare the cost and relative affordability of fluoride toothpaste in high-, middle- and low-income countries. The hypothesis is that fluoride toothpaste is not equally affordable in high-, middle- and low-income countries. Methods Data on consumer prices of fluoride toothpastes were obtained from a self-completion questionnaire from 48 countries. The cost of fluoride toothpaste in high-, middle- and low-income countries was compared and related to annual household expenditure as well as to days of work needed to purchase the average annual usage of toothpaste per head. Results The general trend seems to be that the proportion of household expenditure required to purchase the annual dosage of toothpaste increases as the country's per capita household expenditure decreases. While in the UK for the poorest 30% of the population only 0.037 days of household expenditure is needed to purchase the annual average dosage (182.5 g of the lowest cost toothpaste, 10.75 days are needed in Kenya. The proportion of annual household expenditure ranged from 0.02% in the UK to 4% in Zambia to buy the annual average amount of lowest cost toothpaste per head. Conclusion Significant inequalities in the affordability of this essential preventive care product indicate the necessity for action to make it more affordable. Various measures to improve affordability based on experiences from essential pharmaceuticals are proposed.

  17. Attenuation of vacuum ultraviolet light in liquid argon

    CERN Document Server

    Neumeier, A; Oberauer, L; Potzel, W; Schönert, S; Dandl, T; Heindl, T; Ulrich, A; Wieser, J

    2015-01-01

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  18. Alimentary fluoride intake in preschool children

    Directory of Open Access Journals (Sweden)

    Lencova Erika

    2011-10-01

    Full Text Available Abstract Background The knowledge of background alimentary fluoride intake in preschool children is of utmost importance for introducing optimal and safe caries preventive measures for both individuals and communities. The aim of this study was to assess the daily fluoride intake analyzing duplicate samples of food and beverages. An attempt was made to calculate the daily intake of fluoride from food and swallowed toothpaste. Methods Daily alimentary fluoride intake was measured in a group of 36 children with an average age of 4.75 years and an average weight of 20.69 kg at baseline, by means of a double plate method. This was repeated after six months. Parents recorded their child's diet over 24 hours and collected duplicated portions of food and beverages received by children during this period. Pooled samples of food and beverages were weighed and solid food samples were homogenized. Fluoride was quantitatively extracted from solid food samples by a microdiffusion method using hexadecyldisiloxane and perchloric acid. The content of fluoride extracted from solid food samples, as well as fluoride in beverages, was measured potentiometrically by means of a fluoride ion selective electrode. Results Average daily fluoride intake at baseline was 0.389 (SD 0.054 mg per day. Six months later it was 0.378 (SD 0.084 mg per day which represents 0.020 (SD 0.010 and 0.018 (SD 0.008 mg of fluoride respectively calculated per kg bw/day. When adding the values of unwanted fluoride intake from the toothpaste shown in the literature (0.17-1.21 mg per day the estimate of the total daily intake of fluoride amounted to 0.554-1.594 mg/day and recalculated to the child's body weight to 0.027-0.077 mg/kg bw/day. Conclusions In the children studied, observed daily fluoride intake reached the threshold for safe fluoride intake. When adding the potential fluoride intake from swallowed toothpaste, alimentary intake reached the optimum range for daily fluoride intake

  19. Fluoride retention in saliva and in dental biofilm after different home-use fluoride treatments

    Directory of Open Access Journals (Sweden)

    Daniela Correia Cavalcante SOUZA

    2014-08-01

    Full Text Available This single-blind, randomized, crossover study aimed at assessing the long-term fluoride concentrations in saliva and in dental biofilm after different home-use fluoride treatments. The study volunteers (n = 38 were residents of an area with fluoridated drinking water. They were administered four treatments, each of which lasted for one week: twice-daily placebo dentifrice, twice-daily fluoride dentifrice, twice-daily fluoride dentifrice and once-daily fluoride mouthrinse, and thrice-daily fluoride dentifrice. At the end of each treatment period, samples of unstimulated saliva and dental biofilm were collected 8 h after the last oral hygiene procedure. Fluoride concentrations in saliva and dental biofilm were analyzed using a specific electrode. The fluoride concentrations in saliva and dental biofilm 8 h after the last use of fluoride products did not differ among treatments. The results of this study suggest that treatments with home-use fluoride products have no long-term effect on fluoride concentrations in saliva and in dental biofilm of residents of an area with a fluoridated water supply.

  20. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    International Nuclear Information System (INIS)

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field

  1. Computer simulation of superionic fluorides

    CERN Document Server

    Castiglione, M

    2000-01-01

    experimentally gives an indication of the correlations between nearby defects is well-reproduced. The most stringent test of simulation model transferability is presented in the studies of lead tin fluoride, in which significant 'covalent' effects are apparent. Other similarly-structured compounds are also investigated, and the reasons behind the adoption of such an unusual layered structure, and the mobility and site occupation of the anions is quantified. In this thesis the nature of ion mobility in cryolite and lead fluoride based compounds is investigated by computer simulation. The phase transition of cryolite is characterised in terms of rotation of AIF sub 6 octahedra, and the conductive properties are shown to result from diffusion of the sodium ions. The two processes appear to be unrelated. Very good agreement with NMR experimental results is found. The Pb sup 2 sup + ion has a very high polarisability, yet treatment of this property in previous simulations has been problematic. In this thesis a mor...

  2. Contraction ionization waves in the argon contracted discharge

    International Nuclear Information System (INIS)

    An investigation of ionization waves in the argon contracted discharge and a definition of their arising propagation mechanism accounting for the specificity of elementary pocesses characteristic of argon are presented. (author)

  3. Discovery of Interstellar Hydrogen Fluoride

    CERN Document Server

    Neufeld, D A; Schilke, P; Phillips, T G; Neufeld, David A.; Zmuidzinas, Jonas; Schilke, Peter; Phillips, Thomas G.

    1997-01-01

    We report the first detection of interstellar hydrogen fluoride. Using the Long Wavelength Spectrometer (LWS) of the Infrared Space Observatory (ISO), we have detected the 121.6973 micron J = 2 - 1 line of HF in absorption toward the far-infrared continuum source Sagittarius B2. The detection is statistically significant at the 13 sigma level. On the basis of our model for the excitation of HF in Sgr B2, the observed line equivalent width of 1.0 nm implies a hydrogen fluoride abundance of 3E-10 relative to H2. If the elemental abundance of fluorine in Sgr B2 is the same as that in the solar system, then HF accounts for ~ 2% of the total number of fluorine nuclei. We expect hydrogen fluoride to be the dominant reservoir of gas-phase fluorine in Sgr B2, because it is formed rapidly in exothermic reactions of atomic fluorine with either water or molecular hydrogen; thus the measured HF abundance suggests a substantial depletion of fluorine onto dust grains. Similar conclusions regarding depletion have previously...

  4. Daily Fluoride Intake from Iranian Green Tea: Evaluation of Various Flavorings on Fluoride Release

    OpenAIRE

    Afshin Maleki; Hiua Daraei; Elham Mohammadi; Shiva Zandi; Pari Teymouri; Amir Hossien Mahvi; Fardin Gharibi

    2016-01-01

    With increased awareness of the health benefits of the compounds in green tea, especially polyphenols, its consumption is rising. The main purpose of this study is to determine the effect of different additives on the released fluoride into tea liquor and also daily fluoride intake. The concentrations of fluoride, nitrate, sulfate, and chloride were measured in 15 different flavored green teas (Refah-Lahijan). The fluoride and other anion concentrations were measured by ion chromatography met...

  5. Fluoride Retention following the Professional Topical Application of 2% Neutral Sodium Fluoride Foam

    OpenAIRE

    Wenqun Song; Shinji Toda; Eri Komiyama; Karin Komiyama; Yuki Arakawa; Dawei He; Hirohisa Arakawa

    2011-01-01

    The objective of the present research was to determine the appropriate amount of fluoride to use professional topical application and the residual amounts of fluoride in the oral cavity using a 2% neutral sodium fluoride (NaF) foam with a dedicated tray. Using dentition study models, a method for determining the appropriate amount of NaF foam was investigated. In eight adult subjects, the appropriate amount of NaF foam, the concentration of fluoride in the saliva following professional topica...

  6. Comparison of salivary fluoride levels following use of dentifrices containing different concentrations of fluoride

    OpenAIRE

    Nagpal D; Damle S

    2007-01-01

    Many industrialized countries have reported a decline in caries prevalence over the past few decades. These reductions have been related to the regular use of fluoride dentifrices. Fluoride dentifrices are the most cost-effective and efficient means of caries prevention. However, there have been concerns regarding the risk of fluorosis in children due to the ingestion of dentifrices. This has led to the use of dentifrices with low concentration of fluoride. Salivary fluoride levels after toot...

  7. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  8. Antiapoptotic activity of argon and xenon.

    Science.gov (United States)

    Spaggiari, Sabrina; Kepp, Oliver; Rello-Varona, Santiago; Chaba, Kariman; Adjemian, Sandy; Pype, Jan; Galluzzi, Lorenzo; Lemaire, Marc; Kroemer, Guido

    2013-08-15

    Although chemically non-reactive, inert noble gases may influence multiple physiological and pathological processes via hitherto uncharacterized physical effects. Here we report a cell-based detection system for assessing the effects of pre-defined gas mixtures on the induction of apoptotic cell death. In this setting, the conventional atmosphere for cell culture was substituted with gas combinations, including the same amount of oxygen (20%) and carbon dioxide (5%) but 75% helium, neon, argon, krypton, or xenon instead of nitrogen. The replacement of nitrogen with noble gases per se had no effects on the viability of cultured human osteosarcoma cells in vitro. Conversely, argon and xenon (but not helium, neon, and krypton) significantly limited cell loss induced by the broad-spectrum tyrosine kinase inhibitor staurosporine, the DNA-damaging agent mitoxantrone and several mitochondrial toxins. Such cytoprotective effects were coupled to the maintenance of mitochondrial integrity, as demonstrated by means of a mitochondrial transmembrane potential-sensitive dye and by assessing the release of cytochrome c into the cytosol. In line with this notion, argon and xenon inhibited the apoptotic activation of caspase-3, as determined by immunofluorescence microscopy coupled to automated image analysis. The antiapoptotic activity of argon and xenon may explain their clinically relevant cytoprotective effects. PMID:23907115

  9. Argon-ion contamination of the plasmasphere

    International Nuclear Information System (INIS)

    This paper applies present observational and analytic knowledge on effects of plasma beam interaction wth the magnetosphere to the plasmasphere contamination problem of the argon ion engine exhaust expected to be deposited in the magnetosphere during the construction phase of the Satellite Power System. Effects of plasmasphere, ionosphere, and radiation belt modifications are discussed

  10. Near-infrared scintillation of liquid argon

    Science.gov (United States)

    Alexander, T.; Escobar, C. O.; Lippincott, W. H.; Rubinov, P.

    2016-03-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 μm motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  11. Silicon compounds of neon and argon

    Czech Academy of Sciences Publication Activity Database

    Roithová, J.; Schröder, Detlef

    -, č. 46 (2009), s. 8788-8790. ISSN 1433-7851 R&D Projects: GA ČR GA203/09/1223 Grant ostatní: ERC(XE) Adg HORIZOMS Institutional research plan: CEZ:AV0Z40550506 Keywords : argon * bond formation * dications * neon Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 11.829, year: 2009

  12. Ruthenium olefin metathesis catalysts containing fluoride

    OpenAIRE

    Guidone, Stefano; Songis, Olivier; Falivene, Laura; Nahra, Fady; Slawin, Alexandra Martha Zoya; Jacobsen, Heiko; Cavallo, Luigi; Cazin, Catherine S. J.

    2015-01-01

    The authors gratefully acknowledge the EC through the 7th framework program (grant CP-FP 211468-2 EUMET), the Royal Society (University Research Fellowship to CSJC) for financial support. The reaction of the ruthenium complex cis-Caz-1 with silver fluoride affords the first example of an active olefin metathesis pre-catalyst containing fluoride ligands. The cis geometry of the precursor complex is key to the successful fluoride exchange reaction. Computational studies highlight the stabili...

  13. Estuarine response of fluoride - Investigations in Azhikode Estuary

    Digital Repository Service at National Institute of Oceanography (India)

    Balachandran, K.K.; Joseph, T.; Sankaranarayanan, V.N.

    Concentrations of fluoride in Azhikode estuarine region (Kerala, India) were measured as a function of chlorinity during the different seasons. The type of behaviour indicated that fluoride was regulated by sea water incursion alone. Fluoride...

  14. Fluoride bioavailability in saliva and plaque

    OpenAIRE

    Naumova Ella A; Kuehnl Phillip; Hertenstein Philipp; Markovic Ljubisa; Jordan Rainer A; Gaengler Peter; Arnold Wolfgang H

    2012-01-01

    Abstract Background Different fluoride formulations may have different effects on caries prevention. It was the aim of this clinical study to assess the fluoride content, provided by NaF compared to amine fluoride, in saliva and plaque. Methods Eight trained volunteers brushed their teeth in the morning for 3 minutes with either NaF or amine fluoride, and saliva and 3-day-plaque-regrowth was collected at 5 time intervals during 6 hours after tooth brushing. The amount of collected saliva and ...

  15. Argon Laser Treatment of Strawberry Hemangioma in Infancy

    OpenAIRE

    Achauer, Bruce M.; Vander Kam, Victoria M.

    1985-01-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results.

  16. Gramicidin D enhances the antibacterial activity of fluoride

    OpenAIRE

    Nelson1, James W.; ZHOU, ZHIYUAN; Breaker, Ronald R.

    2014-01-01

    Fluoride is a toxic anion found in many natural environments. One of the major bacterial defenses against fluoride is the cell envelope, which limits passage of the membrane-impermeant fluoride anion. Accordingly, compounds that enhance the permeability of bacterial membranes to fluoride should also enhance fluoride toxicity. In this study, we demonstrate that the pore-forming antibiotic gramicidin D increases fluoride uptake in B. subtilis and that the antibacterial activity of this compound...

  17. Analysis of 1-Minute Potentially Available Fluoride from Dentifrice

    OpenAIRE

    Carey, Clifton M.; Holahan, Erin C; Schmuck, Burton D

    2014-01-01

    Previous reports found that some fluoride-containing dentifrices do not release effective concentrations of fluoride during brushing. Failure to release fluoride can be due to dentifrice matrix components that interfere with the solubilization of the fluoride salts during brushing. A new generation of dentifrices has the capability to precipitate beneficial fluoride salts during tooth brushing. Therefore, a method that assesses the potentially available fluoride during the 1-minute brushing i...

  18. Fluoride in cerebrospinal fluid of patients with fluorosis.

    OpenAIRE

    Hu, Y H; Wu, S S

    1988-01-01

    The CSF fluoride level of individuals drinking water with normal fluoride content and of patients with endemic fluorosis were studied. For the purpose of studying the relationship between the dynamic equilibrium of the CSF fluoride and other body fluids, urine and blood fluoride were examined simultaneously. Fluoride was revealed in every CSF sample of the control group and its mean value was lower than that of the blood. The CSF fluoride concentration of patients with fluorosis was slightly ...

  19. Urinary fluoride output in children following the use of a dual-fluoride varnish formulation

    Directory of Open Access Journals (Sweden)

    Kelly Polido Kaneshiro Olympio

    2009-06-01

    Full Text Available OBJECTIVE: This study evaluated the bioavailability of fluoride after topical application of a dual-fluoride varnish commercially available in Brazil, when compared to DuraphatTM. MATERIAL AND METHODS: The urinary fluoride output was evaluated in seven 5-year-old children after application of the fluoride varnishes, in two different phases. In the first phase (I, children received topical application of the fluoride varnish Duofluorid XII (2.92% fluorine, calcium fluoride + 2.71% fluorine, sodium fluoride, FGM TM. After 1-month interval (phase II, the same amount (0.2 mL of the fluoride varnish Duraphat (2.26% fluorine, sodium fluoride, ColgateTM was applied. Before each application all the volunteers brushed their teeth with placebo dentifrice for 7 days. Urinary collections were carried out 24 h prior up to 48 h after the applications. Fluoride intake from the diet was also estimated. Fluoride concentration in diet samples and urine was analyzed with the fluoride ion-specific electrode and a miniature calomel reference electrode coupled to a potentiometer. Data were tested by ANOVA and Tukey's post hoc test (p<0.05. RESULTS: There were significant differences in the urinary fluoride output between phases I and II. The use of Duofluorid XII did not significantly increase the urinary fluoride output, when compared to baseline levels. The application of Duraphat caused a transitory increase in the urinary fluoride output, returning to baseline levels 48 h after its use. CONCLUSIONS: The tested varnish formulation, which has been shown to be effective in in vitro studies, also can be considered safe.

  20. HOUSEHOLD PURIFICATION OF FLUORIDE CONTAMINATED MAGADI (TRONA)

    DEFF Research Database (Denmark)

    Nielsen, Joan Maj; Dahi, Elian

    1997-01-01

    Purification of fluoride contaminated magadi is studied using bone char sorption and calcium precipitation. The bone char treatment is found to be workable both in columns and in batches where the magadi is dissolved in water prior to treatment. The concentrations in the solutions were 89 g magadi...... treatment method. A procedure for purification of fluoride contaminated magadi at household level is described....

  1. Growth of hollow nickel fluoride whiskers

    International Nuclear Information System (INIS)

    Hollow nickel fluoride whiskers have been obtained by condensation from the vapor phase onto a platinum substrate in a flow of hydrogen fluoride. Crystals up to 5 mm in length have a square cross section with a 300 ± 30-μm side. The wall thickness is 85 ± 20 μm.

  2. Reaction of uranyl fluoride with sodium fluoride in aqueous solution

    International Nuclear Information System (INIS)

    The formation of complex uranyl fluorides in the system NaF-VO2F2-H2O has been studied and some of their properties have been investigated. It has been shown that, depending on the mole ratio of the components (from 0.5:1 to 5:1), fluorouranylates Na(VO2)2F5x4H2O, Na3(VO2)2F7x2H2O, and Na3VO2F5 are formed. Infrared spectra have demonstrated that H2O molecules are not coordinated by the central atom. Dehydration of hydrated complexes proceeds in two stages. Non-aqueous Na3(VO2)2F5 melts at 540 deg C. The synthesized complexes are studied by X-ray structural analysis. The compositions of complex uranyl fluorides formed in the systems MF-VO2F2-H2O (M=Na,K,Rb,Cs,NH4, CN3H6) have been compared

  3. Determination of fluoride content in drinking water and tea infusions using fluoride ion selective electrode

    Directory of Open Access Journals (Sweden)

    Rajković Miloš B.

    2007-01-01

    Full Text Available Potentiometric analysis of fluoride content (as F- ion in solutions by using fluoride ion-selective electrode is simple, reliable and cheap. Very small concentrations of fluoride-ions (to 10-6 mol/dm3 can be determined by fluoride selective electrode, with regulation of ion strength of a solution and control of concentration of hydroxide ions and interfering ions of metals. The influence of pH and complexing ions of metals can be successfully regulated by the TISAB solution and by preserving pH value in the range from 5.00 to 7.00. The content of fluorides in the samples can be determined by the method of direct potentiometer, and in the case of very low concentration by standard addition method. In this paper it was analyzed the determination of fluoride ions concentration in bottled mineral waters and water from Belgrade plumbing in two Belgrade districts (Palilula and Novi Beograd and in tea, by using the fluoride selective electrode. It was determined that the content of fluoride ions in bottled mineral water significantly differs from values given on declaration, and that content of fluoride ions varies over a period of time. The content of fluoride ions in water from plumbing in two Belgrade districts at the time of analysis was significantly increased and exceeded values given in Regulation for drinking water quality. The received results from the analysis of fluorides in teas show that fluorides exist in teas in different concentrations. There are also differences between the same kinds of tea, which is noted with mint (Mentha piperitae folium, as a consequence of differences between soils where it was planted. As taking of fluorides, according to World Health Organisation recommendation (WHO, is limited in the range from 2 to 4 mg per day, it is necessary to give the content of fluorides on all products that are used in human consumption.

  4. Niobium electrodeposition from molten fluorides

    International Nuclear Information System (INIS)

    Niobium electrodeposition from molten alkali fluorides has been studied aiming the application of this technic to the processes of electrorefining and galvanotechnic of this metal. The effects of current density, temperature, niobium concentration in the bath, electrolysis time, substrate nature, ratio between anodic and cathodic areas, electrodes separation and the purity of anodes were investigated in relation to the cathodic current efficiency, electrorefining, electroplating and properties of the deposit and the electrolytic solution. The work also gives the results of the conctruction and operation of a pilot plant for refractory metals electrodeposition and shows the electrorefining and electroplating compared to those obtained at the laboratory scale. (author)

  5. Manufacture and properties of fluoride cement

    Science.gov (United States)

    Malata-Chirwa, Charles David

    This research work aimed at characterising composition, hydration and physical properties of fluoride cement, by studying samples of the cement obtained from Malawi, and comparing them to ordinary Portland cement. By confirming the suitable characteristics of fluoride cement through this work, the results of the research work provide a good basis for the wider adoption of fluoride cement as an alternative to ordinary Portland cement, especially in developing economies. Numerous accounts have been cited regarding the production and use of fluoride cement. Since there have not been conclusive agreement as to its properties, this study was limited to the theories of successful incorporation of fluoride compounds in the manufacture of fluoride cement. Hence, the properties and characteristics reported in this study relate to the cement currently manufactured in Malawi, and, on a comparative basis only, to that manufactured in other parts of the world. Samples of the fluoride cement used in the study were obtained by synthetic manufacture of the cement using common raw materials for the manufacture of fluoride cement that is limestone, silica sand, and fluorspar. These samples were subjected to several comparative tests used to characterise cements including examination under x-ray diffractometer, scanning electron microscopy and tests for setting time and compressive strength. Under similar laboratory conditions, it was possible to prove that fluoride cement hardens more rapidly than ordinary Portland cement. Also observed during the experimental work is that fluoride cement develops higher compressive strengths than ordinary Portland cement. The hardening and setting times are significantly different between the two cements. Also the nature of the hydration products, that is the microstructural development is significantly different in the two cements. The differences brought about between the two cements are because of the presence of fluorine during the clinkering

  6. Argon laser irradiation of the otolithic organ

    Energy Technology Data Exchange (ETDEWEB)

    Okuno, T.; Nomura, Y.; Young, Y.H.; Hara, M. (Univ. of Tokyo (Japan))

    1990-12-01

    An argon laser was used to irradiate the otolithic organs of guinea pigs and cynomolgus monkeys. After stapedectomy, the argon laser (1.5 W x 0.5 sec/shot) irradiated the utricle or saccule without touching the sensory organs. The stapes was replaced over the oval window after irradiation. The animals used for acute observation were killed immediately for morphologic studies; those used for long-term observation were kept alive for 2, 4, or 10 weeks. Acute observation revealed that sensory and supporting cells were elevated from the basement membrane only in the irradiated area. No rupture of the membranous labyrinth was observed. Long-term observation revealed that the otolith of the macula utriculi had disappeared in 2-week specimens. The entire macula utricili had disappeared in 10-week specimens. No morphologic changes were observed in cochlea, semicircular canals, or membranous labyrinth. The saccule showed similar changes.

  7. Explanation of the memory effect in argon

    Directory of Open Access Journals (Sweden)

    Marković Vidosav

    2005-01-01

    Full Text Available Memory effect - the long time variation of the electrical breakdown time delay on the relaxation time td (τ was observed in argon 24 hours after relaxation times and explained by the long-lived metastable states remaining from the preceding glow. However, the quenching processes reducing the effective lifetime of metastable states several orders of magnitude below that relevant for the time scale of observation were neglected. By applying approximate gas phase models it was found that the early afterglow kinetics up to hundreds of milliseconds is dominated by the decay of molecular argon ions Ar2+ and the approximate value of their ambipolar diffusion coefficient is determined. After that, nitrogen atoms present as impurities and recombined on the cathode surface and/or field emission determine the breakdown time delay down to the cosmic rays and natural radioactivity level.

  8. Flow Parameters of Argon plasma Discharge

    International Nuclear Information System (INIS)

    Owing to the viscosity, the plasma will be adhering to the inner surface of the outer electrode and outer surface of the inner one. As result that the discharge will be eroding the walls of coaxial system. The thickness of the boundary layer near the walls has been estimated at different positions from the breech of coaxial plasma gun. It is found that the thickness of layer 0.008 cm at the end of inner electrode (17 cm). A coaxial plasma gun device is operated in argon gas at ambient pressure 0.6 Torr and discharge voltage about 10 KV. The electron temperature of argon discharge has been determined by using spectroscopic technique. It is found that kTe=3.4 eV. By knowing the thickness of the boundary layer, the density can be determined. The Reynolds number R=105 and Mach number M=5 i.e. the flow is compressible and hypersonic

  9. ATLAS liquid argon calorimeter back end electronics

    CERN Document Server

    Bán, J; Bellachia, F; Blondel, A; Böttcher, S; Clark, A; Colas, Jacques; Díaz-Gómez, M; Dinkespiler, B; Efthymiopoulos, I; Escalier, M; Fayard, Lo; Gara, A; He, Y; Henry-Coüannier, F; Hubaut, F; Ionescu, G; Karev, A; Kurchaninov, L; Lafaye, R; Laforge, B; La Marra, D; Laplace, S; Le Dortz, O; Léger, A; Liu, T; Martin, D; Matricon, P; Moneta, L; Monnier, E; Oberlack, H; Parsons, J A; Pernecker, S; Perrot, G; Poggioli, L; Prast, J; Przysiezniak, H; Repetti, B; Rosselet, L; Riu, I; Schwemling, P; Simion, S; Sippach, W; Strässner, A; Stroynowski, R; Tisserant, S; Unal, G; Wilkens, H; Wingerter-Seez, I; Xiang, A; Yang, J; Ye, J

    2007-01-01

    The Liquid Argon calorimeters play a central role in the ATLAS (A Toroidal LHC Apparatus) experiment. The environment at the Large Hadron Collider (LHC) imposes strong constraints on the detectors readout systems. In order to achieve very high precision measurements, the detector signals are processed at various stages before reaching the Data Acquisition system (DAQ). Signals from the calorimeter cells are received by on-detector Front End Boards (FEB), which sample the incoming pulse every 25ns and digitize it at a trigger rate of up to 75~kHz. Off-detector Read Out Driver (ROD) boards further process the data and send reconstructed quantities to the DAQ while also monitoring the data quality. In this paper, the ATLAS Liquid Argon electronics chain is described first, followed by a detailed description of the off-detector readout system. Finally, the tests performed on the system are summarized.

  10. Determination of Fluoride in Different Toothpaste Formulations

    International Nuclear Information System (INIS)

    Fluoride ion selective electrode was used to determine fluoride ion concentrations in seven brands of toothpaste. These were the only available formulations found in Kenya. The brands were classified into three groups-fluoridated, non fluoridated or not indicated. However, there was no independent indication of their quantitative composition. The analysed brands had fluoride content between 0.0033% and 0.096%. These values compared favourably with those obtained elsewhere. The calculated lowest limit of detection (LLD) was 0.01 ppmF- . The mean calibration curve gave a slope of of -50.0mV. which was not significantly different from the theoretical value of 5.88mV at 23 degrees celsius at 95% confidence level

  11. Substoichiometric precipitation of fluoride with lanthanum

    International Nuclear Information System (INIS)

    The substoichiometric precipitation of fluoride with lanthanum was studied by using 18F and 140La tracers. It was found that fluoride could be precipitated substoichiometrically with lanthanum and the reaction ratio between fluoride and lanthanum was 3:1. The pH range at which fluoride can be separated subsotichiometrically with lanthanum is between 2 and 8. Barium and indium interfere in the precipitation of fluoride, but sodium, copper and manganese do not. Fluorosilicate can also be precipitated subsotichiometrically by using lanthanum as a precipitant and the reaction ratio between fluorosilicate and lanthanum was 1:2. This separation was applied for the determination of oxygen in silicon crystals. The concentration of oxygen measured in some silicon crystals was between 5 and 27 ppm and was in good agreement with those by non-destructive method and infrared spectrophotometry. (author)

  12. Recent advancements in fluoride: A systematic review

    Science.gov (United States)

    Bansal, Ankita; Ingle, Navin Anand; Kaur, Navpreet; Ingle, Ekta

    2015-01-01

    To review advancements of fluoride in dentistry, a search of 21 electronic databases and World Wide Web was conducted. Relevant journals were hand searched and further information was requested from authors. Inclusion criteria were a predefined hierarchy of evidence and objectives. Study validity was assessed with checklists. Two reviewers independently screened sources, extracted data, and assessed validity. Fluoride has become an important tool in preventive dentistry. Current research is focused on the development of strategies to improve fluoride efficacy. Fluoride therapy in the form of varnish, gel, mouth rinse, or toothpaste has been used extensively as a caries-preventive intervention for over three decades. The purpose of this review is to inform the reader about new research related to the use of fluoride for the prevention of dental caries. PMID:26539383

  13. Method of treating fluoride contaminated wastes

    Energy Technology Data Exchange (ETDEWEB)

    Davis, P.K.; Kakaria, V.K.

    1988-04-05

    A method for treating spent aluminum smelting potliner material containing fluoride contaminants is described which comprises: adding silica to the material to form a mixture thereof; elevating the temperature of the mixture within the range of 1,000/sup 0/ to 1,700/sup 0/C. to form a slag; providing sufficient silica in the mixture and forming the slag in the presence of sufficient water for pyrohydrolysis conditions resulting in the volatilization of substantially all of the fluoride contaminants mostly in the form of hydrogen fluoride; and cooling the slag remaining after volatilizatiion of substantially all of the fluoride contaminants to produce an insoluble silicate glass-residue containing any remaining portion of the fluoride contaminants in an immobile state.

  14. Fluoride Importance in Controlling Caries and Fluorosis

    Directory of Open Access Journals (Sweden)

    Gaurav Solanki

    2012-04-01

    Full Text Available The use of fluorides for oral health has always involved a balance between the protective benefit against dental caries and the risk of developing fluorosis. The link between fluoride and dental health was established to determining the causes of dental fluorosis or enamel mottling. Fluorosis in Indian children was highly prevalent in the early 1990s. Policy were introduced to control fluoride exposure and to reduce the prevalence of fluorosis. The study aimed of describing the prevalence, severity and risk factors for fluorosis, and to describe the trend of fluorosis among Indian children. The study also aimed of exploring the effect of the change in fluoride exposure on dental fluorosis and caries. Establishing an appropriate use of fluoride toothpaste could be successful in reducing fluorosis without a significant increase in caries experience.

  15. Current and future liquid argon neutrino experiments

    International Nuclear Information System (INIS)

    The liquid argon time projection chamber (LArTPC) detector technology provides an opportunity for precision neutrino oscillation measurements, neutrino cross section measurements, and searches for rare processes, such as SuperNova neutrino detection. These proceedings review current and future LArTPC neutrino experiments. Particular focus is paid to the ICARUS, MicroBooNE, LAr1, 2-LArTPC at CERN-SPS, LBNE, and 100 kton at Okinoshima experiments

  16. Liquid argon imaging a novel detection technology

    CERN Document Server

    Rubbia, Carlo

    2002-01-01

    Ionisation electrons may drift over large distances (meters) in a volume of highly purified liquid argon (O2 equivalent less than 0.1 ppb!) under the action of an electric field. With an appropriate readout system (i.e. a set of fine pitch wire grids) we have realised a massive, continuously sensitive 'bubble chamber' with multiple readouts of the same, small charge (a minimum ionising track segment, 2 mm long, yields • 10000 electrons). We have developed this technology since 1987, initially with small laboratory devices and later with progressively larger and more sophisticated detectors, the latest being the T600 module (740 ton of liquid Argon), which has been operated in Pavia, as a step toward the ICARUS programme in the Gran Sasso Laboratory (LNGS). With cloning of T600 we aim at a 3000 ton detector by 2005. Argon is a medium with density 1.4 g/cm3, similar in characteristics to the heavy freon used in the famous Gargamelle. With wire pitches of 2-3 mm, it provides an extremely high spatial re...

  17. Distribution and Abundance of Mars' Atmospheric Argon

    Science.gov (United States)

    Sprague, A. L.; Boynton, W. V.; Kerry, K. E.; Nelli, Steven; Murphy, Jim; Reedy, R. C.; Metzger, A. E.; Hunten, D. M.; Janes, K. D.; Crombie, M. K.

    2005-01-01

    One and one half Mars years (MY 26 and 27) of atmospheric Argon measurements are described and studied in the context of understanding how Argon, a minor constituent of Mars atmosphere that does not condense at Mars temperatures, can be used to study martian circulation and dynamics. Argon data are from the 2001 Mars Odyssey Gamma Subsystem (GS) of the suite of three instruments comprising the Gamma Ray Spectrometer (GRS). A comprehensive data analysis including gamma-ray production and attenuation by the atmosphere is included. Of particular interest is the enhanced abundance of Ar over the observed Ar abundance at lower latitudes at south (up to a factor of 10) and north (up to a factor of 4) polar regions during winter. Calibration of the measurements to actual Ar abundance is possible because GS measurements cover the same latitude and season as measurements made by the gas chromatograph mass spectrometer (GCMS) on Viking Landers 1 and 2 (VL1 and VL2). [2].

  18. Dental fluorosis and skeletal fluoride content as biomarkers of excess fluoride exposure in marsupials.

    Science.gov (United States)

    Death, Clare; Coulson, Graeme; Kierdorf, Uwe; Kierdorf, Horst; Morris, William K; Hufschmid, Jasmin

    2015-11-15

    Particulate and gaseous fluoride emissions contaminate vegetation near fluoride-emitting industries, potentially impacting herbivorous wildlife in neighboring areas. Dental fluorosis has been associated with consumption of fluoride-contaminated foliage by juvenile livestock and wildlife in Europe and North America. For the first time, we explored the epidemiology and comparative pathology of dental fluorosis in Australian marsupials residing near an aluminium smelter. Six species (Macropus giganteus, Macropus rufogriseus, Wallabia bicolor, Phascolarctos cinereus, Trichosurus vulpecula, Pseudocheirus peregrinus) demonstrated significantly higher bone fluoride levels in the high (n=161 individuals), compared to the low (n=67 individuals), fluoride areas (p<0.001). Necropsy examinations of all six species from the high-fluoride area near the smelter revealed dental lesions considered characteristic of dental fluorosis in eutherian mammals. Within the high-fluoride area, 67% of individuals across the six species showed dental enamel lesions, compared to 3% in the low-fluoride areas. Molars that erupted before weaning were significantly less likely to display pathological lesions than those developing later, and molars in the posterior portion of the dental arcade were more severely fluorotic than anterior molars in all six species. The severity of dental lesions was positively associated with increasing bone fluoride levels in all species, revealing a potential biomarker of excess fluoride exposure. PMID:26188404

  19. 21 CFR 175.270 - Poly(vinyl fluoride) resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Poly(vinyl fluoride) resins. 175.270 Section 175... Substances for Use as Components of Coatings § 175.270 Poly(vinyl fluoride) resins. Poly(vinyl fluoride... the purpose of this section, poly(vinyl fluoride) resins consist of basic resins produced by...

  20. Fluoride Programs in the School Setting: Preventive Dental Health.

    Science.gov (United States)

    Rebich, Theodore, Jr.; And Others

    1982-01-01

    Two types of school-based programs that increase students' use of fluoride for preventive dental health are described. In fluoride mouthrinse programs, teachers give their students a fluoride solution once a week in a paper cup. In areas where the level of fluoride in the water supply is insufficient, the flouride tablet program is used. (JN)

  1. Evaluation of toxic action of fluorides on agricultural plants

    Directory of Open Access Journals (Sweden)

    V. N. Grishko

    2007-03-01

    Full Text Available The toxicity of potassium fluoride, sodium fluoride and ammonium fluoride for pea, maize, oat and onion was studied. It was found that the level of the toxic influence had grown with increase of fluoride concentration in the media of growth (from 5 to 100 mg of F–/l. By increase of the toxic influence the agricultural crops are disposed in the following row: oat < onion < maize < pea. Ammonium fluoride demonstrates lesser toxicity, than potassium and sodium fluorides. Under low concentrations of fluoride compounds (5 and 10 mg of F–/l stimulation of roots growth is noted only for the oat.

  2. Fluoride

    Science.gov (United States)

    ... is sometimes prescribed for other uses; ask your doctor or pharmacist for more information. ... on your prescription label carefully, and ask your doctor or pharmacist to explain any part you do not understand. ...

  3. Physiologic Conditions Affect Toxicity of Ingested Industrial Fluoride

    Directory of Open Access Journals (Sweden)

    Richard Sauerheber

    2013-01-01

    Full Text Available The effects of calcium ion and broad pH ranges on free fluoride ion aqueous concentrations were measured directly and computed theoretically. Solubility calculations indicate that blood fluoride concentrations that occur in lethal poisonings would decrease calcium below prevailing levels. Acute lethal poisoning and also many of the chronic effects of fluoride involve alterations in the chemical activity of calcium by the fluoride ion. Natural calcium fluoride with low solubility and toxicity from ingestion is distinct from fully soluble toxic industrial fluorides. The toxicity of fluoride is determined by environmental conditions and the positive cations present. At a pH typical of gastric juice, fluoride is largely protonated as hydrofluoric acid HF. Industrial fluoride ingested from treated water enters saliva at levels too low to affect dental caries. Blood levels during lifelong consumption can harm heart, bone, brain, and even developing teeth enamel. The widespread policy known as water fluoridation is discussed in light of these findings.

  4. New Insight on the Response of Bacteria to Fluoride

    OpenAIRE

    Breaker, R R

    2012-01-01

    Fluoride has been used for decades to prevent caries and it is well established that this anion can inhibit the growth of bacteria. However, the precise effects that fluoride has on bacteria and the mechanisms that bacteria use to overcome fluoride toxicity have largely remained unexplored. Recently, my laboratory reported the discovery of biological systems that bacteria use to sense fluoride and reduce fluoride toxicity. These sensors and their associated genes are very widespread in biolog...

  5. Current Concept on the Anticaries Fluoride Mechanism of the Action

    OpenAIRE

    Rošin-Grget, K.; Linčir, I.

    2001-01-01

    The paper discusses a possible new concept of the role of fluoride and its mechanism of action in caries prevention. In the past fluoride inhibition of caries was ascribed to reduced solubility due to incorporation of fluoride (F–) into the enamel minerals (firmly bound fluoride or fluorapatite). Based on the new findings, it appears that fluoride, either released into or present in the fluid phase bathing the hard tissue, is more important for the reduction of caries developme...

  6. Topical fluoride as a cause of dental fluorosis in children

    OpenAIRE

    Wong, MCM; Lo, ECM; Glenny, AM; Tsang, BWK; Worthington, HV; Marinho, VCC

    2009-01-01

    BACKGROUND: For many years, topical use of fluorides has gained greater popularity than systemic use of fluorides. A possible adverse effect associated with the use of topical fluoride is the development of dental fluorosis due to the ingestion of excessive fluoride by young children with developing teeth. OBJECTIVES: To describe the relationship between the use of topical fluorides in young children and the risk of developing dental fluorosis. SEARCH STRATEGY: Electronic search of the Cochra...

  7. Physiologic Conditions Affect Toxicity of Ingested Industrial Fluoride

    OpenAIRE

    Richard Sauerheber

    2013-01-01

    The effects of calcium ion and broad pH ranges on free fluoride ion aqueous concentrations were measured directly and computed theoretically. Solubility calculations indicate that blood fluoride concentrations that occur in lethal poisonings would decrease calcium below prevailing levels. Acute lethal poisoning and also many of the chronic effects of fluoride involve alterations in the chemical activity of calcium by the fluoride ion. Natural calcium fluoride with low solubility and toxicity ...

  8. Development of a low-cost inductively coupled argon plasma

    International Nuclear Information System (INIS)

    The aim of this investigation is to drastically reduce running costs of an inductively coupled plasma. This is done by reducing the argon consumption from 20 l/min to about 1 l/min. First, a sample introduction system operating on 0.1 l/min of carrier argon is described. This system ensures a high ratio of plasma argon and carrier argon even at the low total argon consumptions intended. Next, the developed low consumption plasma is presented. In the proposed design, air is blown perpendicularly against the outside of the torch. A different coil has been developed to make air-cooling efficient. Preliminary data on coupling efficiency for the air-cooled plasma are presented. A similarly low argon consumption has been achieved with water as an external coolant medium. It is concluded that a cheaper alternative to the current ICP has become available. (Auth.)

  9. Technology of obtaining of cryolite and aluminium fluoride from alumina- and fluoride containing wastes of aluminium production

    International Nuclear Information System (INIS)

    This article is devoted to technology of obtaining of cryolite and aluminium fluoride from alumina- and fluoride containing wastes of aluminium production. Thus, the investigations on elaboration of technology of obtaining of cryolite and aluminium fluoride from alumina- and fluoride containing wastes of aluminium production by means of sulfuric acid decomposition method are carried out. The optimal parameters of technological processes are found. The physicochemical analysis of fluoride containing wastes is conducted. The flowsheet of obtaining of cryolite, aluminium fluoride and alumina from alumina- and fluoride containing wastes is presented.

  10. Direct WIMP Detection Using Scintillation Time Discrimination in Liquid Argon

    OpenAIRE

    Boulay, M. G.; Hime, A.

    2004-01-01

    Discrimination between electron and nuclear recoil events in a liquid argon scintillation detector has been demonstrated with simulations by using the differences in the scintillation photon time distribution between these classes of events. A discrimination power greater than 10^{8} is predicted for a liquid argon experiment with a 10 keV threshold, which would mitigate electron and gamma-ray backgrounds, including beta decays of 39-Ar and 42-Ar in atmospheric argon. A dark matter search usi...

  11. Effects of Nitrogen contamination in liquid Argon

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Baibussinov, B.; Baldo-Ceolin, M.; Benetti, P.; Calaprice, F.; Calligarich, E.; Cambiaghi, M.; Canci, N.; Carbonara, F.; Cavanna, F.; Centro, S.; Cocco, A. G.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Gallo, V.; Grandi, L.; Meng, G.; Modena, I.; Montanari, C.; Palamara, O.; Pandola, L.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Roncadelli, M.; Rossella, M.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Ventura, S.; Vignoli, C.

    2010-06-01

    A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. The purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from ~ 10-1 ppm up to ~ 103 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (γ-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. Direct PMT signal acquisition exploiting high time resolution by fast waveform recording allowed high precision extraction of the main characteristics of the scintillation light emission in contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable starting from Script O(1 ppm) of Nitrogen concentrations. The rate constant of the quenching process induced by Nitrogen in liquid Ar has been found to be kQ(N2) = 0.11 ± 0.01 μs-1ppm-1, consistent with a previous measurement of this quantity but with significant improvement in precision. On the other hand, no evidence for absorption by N2 impurities has been found up to the higher concentrations here explored.

  12. The Adsorption of Hydrogen Fluoride and Fluoride Ion on a Water Treatment Sludge

    OpenAIRE

    Oh, Taek-Keun; Saeki, Kazutoshi

    2009-01-01

    The hydrogen fluoride (HF) and fluoride ion (F^-) adsorption potentials of a water treatment sludge were investigated in a batch mode as a function of pH, contact time, initial fluoride concentrations, and other co-existing anions. The maximum removal of total fluoride was apparently observed at pH 5.1, whereas HF or F^- adsorptions showed nearly 100% in pH range from 2.2 to 4.3. The HF or F^- adsorption by the water treatment sludge has occurred rapidly during the initial 5.60 min and therea...

  13. Determination of fluoride content in drinking water and tea infusions using fluoride ion selective electrode

    OpenAIRE

    Rajković Miloš B.; Novaković Ivana D.

    2007-01-01

    Potentiometric analysis of fluoride content (as F- ion) in solutions by using fluoride ion-selective electrode is simple, reliable and cheap. Very small concentrations of fluoride-ions (to 10-6 mol/dm3) can be determined by fluoride selective electrode, with regulation of ion strength of a solution and control of concentration of hydroxide ions and interfering ions of metals. The influence of pH and complexing ions of metals can be successfully regulated by the TISAB solution and by preservin...

  14. HARP: high pressure argon readout for calorimeters

    International Nuclear Information System (INIS)

    Steel tubes of approximately 8 mm O.D., filled with Argon gas to approx.200 bar, are considered as the active element for a charge collecting sampling calorimeter readout system. The tubes are permanently sealed and operated in the ion chamber mode, with the charge collection on a one-millimeter concentric anode. We present the motivation for such a device, including Monte Carlo predictions of performance. The method of construction and signal collection are discussed, with initial results on leakage and ageing of the filling gas. A prototype electromagnetic calorimeter is described

  15. Argon isotope fractionation induced by stepwise heating

    Science.gov (United States)

    Trieloff, Mario; Falter, Martina; Buikin, Alexei I.; Korochantseva, Ekaterina V.; Jessberger, Elmar K.; Altherr, Rainer

    2005-03-01

    Noble gas isotopes are widely used to elucidate the history of the rocks in which they have been trapped, either from distinct reservoirs or by accumulation following radioactive decay. To extract noble gases from their host rocks, stepwise heating is the most commonly used technique to deconvolve isotopically different components, e.g., atmospheric, in situ radiogenic, or excess radiogenic from mantle or crustal reservoirs. The accurate determination of the isotopic composition of these different components is of crucial importance, e.g., for ages obtained by 40Ar- 39Ar stepheating plateaus. However, diffusion theory-based model calculations predict that the stepwise thermal extraction process from mineral phases induces isotope fractionation and, hence, adulterates the original composition. Such effects are largely unconsidered, as they are small and a compelling experimental observation is lacking. We report the first unequivocal evidence for significant mass fractionation of argon isotopes during thermal extraction, observed on shungite, a carbon-rich Precambrian sedimentary rock. The degree of fractionation, as monitored by 38Ar/ 36Ar and 40Ar/ 36Ar ratios, very well agrees with theoretical predictions assuming an inverse square root dependence of diffusion coefficient and atomic mass, resulting in easier extraction of lighter isotopes. Hence, subatmospheric 40Ar/ 36Ar ratios obtained for argon extracted at low temperatures may not represent paleoatmospheric argon. Shungite argon resembles modern atmospheric composition, but constraints on the timing of trapping appear difficult to obtain, as shungites are multicomponent systems. In 40Ar- 39Ar stepwise heating, the isotope fractionation effect could cause systematic underestimations of plateau ages, between 0.15 and 0.4% depending on age, or considerably higher if samples contain appreciable atmospheric Ar. The magnitude of this effect is similar to the presently achieved uncertainties of this increasingly

  16. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  17. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  18. Attosecond Time-Resolved Autoionization of Argon

    International Nuclear Information System (INIS)

    Autoionization of argon atoms was studied experimentally by transient absorption spectroscopy with isolated attosecond pulses. The peak position, intensity, linewidth, and shape of the 3s3p6np 1P Fano resonance series (26.6-29.2 eV) were modified by intense few-cycle near infrared laser pulses, while the delay between the attosecond pulse and the laser pulse was changed by a few femtoseconds. Numerical simulations revealed that the experimentally observed splitting of the 3s3p64p 1P line is caused by the coupling between two short-lived highly excited states in the strong laser field.

  19. Argon Purification Studies and a Novel Liquid Argon Re-circulation System

    CERN Document Server

    Mavrokoridis, K; Coleman, J; Lightfoot, P K; McCauley, N; McCormick, K J; Touramanis, C

    2011-01-01

    Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapou...

  20. Study of fluoride corrosion of nickel alloys

    Science.gov (United States)

    Gunther, W. H.; Steindler, M. J.

    1969-01-01

    Report contains the results of an investigation of the corrosion resistance of nickel and nickel alloys exposed to fluorine, uranium hexafluoride, and volatile fission product fluorides at high temperatures. Survey of the unclassified literature on the subject is included.

  1. ARGON RECOIL ION ELECTRON CAPTURE FROM NEUTRAL ARGON AND HELIUM STUDIED BY TIME RESOLVED V.U.V. SPECTROSCOPY

    OpenAIRE

    Lesteven-Vaisse, I.; Chantepie, M.; Folkmann, F.; Lecler, D.; Ben Sitel, A.

    1989-01-01

    Electron capture phenomena in recoil ion V.U.V. spectroscopy are tested through the evolution of the observed argon spectrum by introduction of helium in addition to argon in the collision chamber. Taking into account these mixed gas data by the time-differential method and using decay time analysis, an improved analysis of argon recoil ion V.U.V. radiation is presented.

  2. Recent advancements in fluoride: A systematic review

    OpenAIRE

    Bansal, Ankita; Ingle, Navin Anand; Kaur, Navpreet; Ingle, Ekta

    2015-01-01

    To review advancements of fluoride in dentistry, a search of 21 electronic databases and World Wide Web was conducted. Relevant journals were hand searched and further information was requested from authors. Inclusion criteria were a predefined hierarchy of evidence and objectives. Study validity was assessed with checklists. Two reviewers independently screened sources, extracted data, and assessed validity. Fluoride has become an important tool in preventive dentistry. Current research is f...

  3. Fluoride removal from water by nano filtration

    International Nuclear Information System (INIS)

    As any oligo element, fluoride is necessary and beneficial for human health to low concentrations, but an excess amount of fluoride ions in drinking water has been known to cause undesirable effects, especially tooth and bones fluoro sis. The maximum acceptable concentration of fluoride in drinking water was fixed by the World Health Organization according to the climate in the range of 1 mg.L-1 to 1,2 mg.L-1. Many methods have been used to remove fluoride from water such as precipitation, adsorption, electrocoagulation and membrane processes. Technologies using membrane processes are being used in many applications, particularly for brackish water desalination. Nano filtration seems to be the best process for a good selective defluorination of fluorinated waters. The main objective of this work was to investigate the retention of fluoride anions by nano filtration. The first part of this study deals with the characterisation of the NF HL2514TF membrane. The influence of various experimental parameters such as initial fluoride content, feed pressure, permeate flux, ionic strength, type of cation associated to fluoride and pH were studied in the second part. Results show that the retention order for the salts tested was TR(Na2SO4) > TR(CaCl2) > TR(NaCl), showing a retention sequence inversely proportional to the salt diffusion coefficients in water. It was also shown that charge effects could not be neglected, and a titration experiments confirmed that the NF membrane carry a surplus of negatively charged groups. Fluoride retention exceeds 60 pour cent, and increases with increasing concentration, where the rejection mechanism is related to the dielectric effects. Speigler-Kedem model was applied to experimental results in the aim to determine phenomenological parametersσand Ps respectively, the reflexion coefficient of the membrane and the solute permeability of ions. The convective and diffusive parts of the mass transfer were quantified with predominance of the

  4. Argon laser-welded arteriovenous anastomoses.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; White, G; Lyons, R; Fujitani, R; Klein, S R; Uitto, J

    1987-11-01

    This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line. PMID:3312648

  5. Electron scattering and transport in liquid argon

    International Nuclear Information System (INIS)

    The transport of excess electrons in liquid argon driven out of equilibrium by an applied electric field is revisited using a multi-term solution of Boltzmann’s equation together with ab initio liquid phase cross-sections calculated using the Dirac-Fock scattering equations. The calculation of liquid phase cross-sections extends previous treatments to consider multipole polarisabilities and a non-local treatment of exchange, while the accuracy of the electron-argon potential is validated through comparison of the calculated gas phase cross-sections with experiment. The results presented highlight the inadequacy of local treatments of exchange that are commonly used in liquid and cluster phase cross-section calculations. The multi-term Boltzmann equation framework accounting for coherent scattering enables the inclusion of the full anisotropy in the differential cross-section arising from the interaction and the structure factor, without an a priori assumption of quasi-isotropy in the velocity distribution function. The model, which contains no free parameters and accounts for both coherent scattering and liquid phase screening effects, was found to reproduce well the experimental drift velocities and characteristic energies

  6. Pollution of liquid argon after neutron irradiation

    CERN Document Server

    Andrieux, M L; Collot, J; de Saintignon, P; Ferrari, A; Hostachy, J Y; Hoummada, A; Martin, P; Merkel, B; Puzo, P; Sauvage, D; Wielers, M

    2001-01-01

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem. (17 refs).

  7. Pollution of liquid argon after neutron irradiation

    International Nuclear Information System (INIS)

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem

  8. Ion-beam excitation of liquid argon

    CERN Document Server

    Hofmann, M; Heindl, T; Neumeier, A; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Wieser, J; Ulrich, A

    2015-01-01

    The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using ou...

  9. Debating Water Fluoridation Before Dr. Strangelove.

    Science.gov (United States)

    Carstairs, Catherine

    2015-08-01

    In the 1930s, scientists learned that small amounts of fluoride naturally occurring in water could protect teeth from decay, and the idea of artificially adding fluoride to public water supplies to achieve the same effect arose. In the 1940s and early 1950s, a number of studies were completed to determine whether fluoride could have harmful effects. The research suggested that the possibility of harm was small. In the early 1950s, Canadian and US medical, dental, and public health bodies all endorsed water fluoridation. I argue in this article that some early concerns about the toxicity of fluoride were put aside as evidence regarding the effectiveness and safety of water fluoridation mounted and as the opposition was taken over by people with little standing in the scientific, medical, and dental communities. The sense of optimism that infused postwar science and the desire of dentists to have a magic bullet that could wipe out tooth decay also affected the scientific debate. PMID:26066938

  10. Well Waters Fluoride in Enugu, Nigeria

    Directory of Open Access Journals (Sweden)

    EI Ugwuja

    2012-03-01

    Full Text Available Abnormal fluoride levels in drinking water have been associated with adverse health effects. To determine the fluoride content of well waters in Enugu, southeastern Nigeria, water samples from 50 artisan wells chosen by multistage sampling procedure from the 5 zones of Enugu municipality were analyzed in duplicates for their fluoride content. The zonal mean values were 0.60, 0.70, 0.62, 0.62, and 0.63 mg/L for Abakpa Nike, Achara Layout, Obiagu/ Ogui, Trans Ekulu and Uwani, respectively (p<0.05. The mean value for the whole city was 0.63 mg/L. Although, the mean level of fluoride recorded in this study is currently within safe limits (1.5 mg/L, WHO 2011, it is important to monitor continuously the fluoride content of well waters in the municipality in view of the increasing industrial activities going on in the city and heavy reliance on well water for domestic purposes and the widespread use of consumer products containing fluoride.

  11. Fluoride geochemistry of thermal waters in Yellowstone National Park: I. Aqueous fluoride speciation

    Science.gov (United States)

    Deng, Y.; Nordstrom, D.K.; Blaine, McCleskey R.

    2011-01-01

    Thermal water samples from Yellowstone National Park (YNP) have a wide range of pH (1-10), temperature, and high concentrations of fluoride (up to 50mg/l). High fluoride concentrations are found in waters with field pH higher than 6 (except those in Crater Hills) and temperatures higher than 50??C based on data from more than 750 water samples covering most thermal areas in YNP from 1975 to 2008. In this study, more than 140 water samples from YNP collected in 2006-2009 were analyzed for free-fluoride activity by ion-selective electrode (ISE) method as an independent check on the reliability of fluoride speciation calculations. The free to total fluoride concentration ratio ranged from 99% at high pH. The wide range in fluoride activity can be explained by strong complexing with H+ and Al3+ under acidic conditions and lack of complexing under basic conditions. Differences between the free-fluoride activities calculated with the WATEQ4F code and those measured by ISE were within 0.3-30% for more than 90% of samples at or above 10-6 molar, providing corroboration for chemical speciation models for a wide range of pH and chemistry of YNP thermal waters. Calculated speciation results show that free fluoride, F-, and major complexes (HF(aq)0, AlF2+, AlF2+ and AlF30) account for more than 95% of total fluoride. Occasionally, some complex species like AlF4-, FeF2+, FeF2+, MgF+ and BF2(OH)2- may comprise 1-10% when the concentrations of the appropriate components are high. According to the simulation results by PHREEQC and calculated results, the ratio of main fluoride species to total fluoride varies as a function of pH and the concentrations and ratios of F and Al. ?? 2011.

  12. Efficacy of silver diamine fluoride as an antibacterial as well as antiplaque agent compared to fluoride varnish and acidulated phosphate fluoride gel: An in vivo study

    OpenAIRE

    Shalin Shah; Vijay Bhaskar; Karthik Venkataraghavan; Prashant Choudhary; M Ganesh; Krishna Trivedi

    2013-01-01

    Background: Silver diamine fluoride (SDF) is already proven as an antibacterial agent in vitro. Present study was formulated to compare the efficacy of SDF as an antibacterial as well as antiplaque agent in vivo with fluoride varnish and acidulated phosphate fluoride (APF) gel. Study Design: Total 123 children (male = 82, female = 41) were included in the study for a period of 18 months. Children were divided into three different groups-Group 1: SDF; Group 2: fluoride varnish; and Group 3...

  13. Chemisorption of uranium hexa-fluoride on sodium fluoride pellets

    International Nuclear Information System (INIS)

    This paper comprises kinetics of chemical reaction or rather chemisorption of uranium hexafluoride gas on sodium fluoride pellets. The chemisorption is essentially irreversible at room temperature, while the process reverses at high temperature above 280 deg C. This chemisorption process was experimentally conducted in static condition at room temperature and its kinetics was studied. In the experiments, practically pure UF6 was used and the effects of gas pressure and weight of NaF pellets, were studied. In this heterogenous reaction, in which diffusion through ash layer is followed by chemical reaction, the reaction part is instantaneous and is first order with respect to gas concentration. Since the process of chemisorption is not only pure chemical reaction but also gas diffusion through ash layer, the rate constant depreciates with the percentage loading of UF6 on NaF pellets. The kinetic equation for the above process has been established for a particular size of NaF pellets and pellet porosity. (author)

  14. Daily Fluoride Intake from Iranian Green Tea: Evaluation of Various Flavorings on Fluoride Release.

    Science.gov (United States)

    Maleki, Afshin; Daraei, Hiua; Mohammadi, Elham; Zandi, Shiva; Teymouri, Pari; Mahvi, Amir Hossien; Gharibi, Fardin

    2016-01-01

    With increased awareness of the health benefits of the compounds in green tea, especially polyphenols, its consumption is rising. The main purpose of this study is to determine the effect of different additives on the released fluoride into tea liquor and also daily fluoride intake. The concentrations of fluoride, nitrate, sulfate, and chloride were measured in 15 different flavored green teas (Refah-Lahijan). The fluoride and other anion concentrations were measured by ion chromatography method. The data were analyzed with Statistical Package for the Social Sciences version 16.0. The results showed that the minimum and maximum concentrations of fluoride in the green tea infusions were 0.162 mg/L (cinnamon-flavored green tea) and 3.29 mg/L (bagged peach-flavored green tea), respectively. The mean concentration of fluoride in the green tea leaves was 52 mg/kg, and approximately 89% of the fluoride was released from the green tea leaves into the infusions after brewing. The fluoride concentrations varied significantly among the examined green teas (P 0.05). Finally, drinking of the studied green teas cannot make a significant contribution to the daily dietary intake of F for consumers. PMID:27042093

  15. Daily Fluoride Intake from Iranian Green Tea: Evaluation of Various Flavorings on Fluoride Release

    Science.gov (United States)

    Maleki, Afshin; Daraei, Hiua; Mohammadi, Elham; Zandi, Shiva; Teymouri, Pari; Mahvi, Amir Hossien; Gharibi, Fardin

    2016-01-01

    With increased awareness of the health benefits of the compounds in green tea, especially polyphenols, its consumption is rising. The main purpose of this study is to determine the effect of different additives on the released fluoride into tea liquor and also daily fluoride intake. The concentrations of fluoride, nitrate, sulfate, and chloride were measured in 15 different flavored green teas (Refah-Lahijan). The fluoride and other anion concentrations were measured by ion chromatography method. The data were analyzed with Statistical Package for the Social Sciences version 16.0. The results showed that the minimum and maximum concentrations of fluoride in the green tea infusions were 0.162 mg/L (cinnamon-flavored green tea) and 3.29 mg/L (bagged peach-flavored green tea), respectively. The mean concentration of fluoride in the green tea leaves was 52 mg/kg, and approximately 89% of the fluoride was released from the green tea leaves into the infusions after brewing. The fluoride concentrations varied significantly among the examined green teas (P 0.05). Finally, drinking of the studied green teas cannot make a significant contribution to the daily dietary intake of F for consumers. PMID:27042093

  16. Nitrogen Removal from Molten Steel under Argon DC Glow Plasma

    Institute of Scientific and Technical Information of China (English)

    SUN Ming-shan; DING Wei-zhong; LU Xiong-gang

    2005-01-01

    Under argon DC glow plasma, the nitrogen removal from molten steel was studied. The experimental result showed that nitrogen mass percent could be reduced to 0.000 8%. The change of polarity had no impact on nitrogen removal when the nitrogen mass percent was low. The mechanism of denitrogenation of molten steel under argon DC glow plasma was discussed.

  17. WARP: a double phase argon programme for dark matter detection

    International Nuclear Information System (INIS)

    WARP (Wimp ARgon Programme) is a double phase Argon detector for Dark Matter search under construction at Laboratori Nazionali del Gran Sasso. We present recent results obtained operating a prototype with a sensitive mass of 2.3 litres deep underground

  18. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.;

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...

  19. Determination of Fluoride in the Bottled Drinking Waters in Iran

    OpenAIRE

    Amanlou, Massoud; Hosseinpour, Maedeh; Azizian, Homa; Khoshayand, Mohammad Reza; Navabpoor, Mojtaba; Souri, Effat

    2010-01-01

    Fluoride is recognized as an effective agent for dental caries prevention. Generally, the main source of fluoride intake is drinking water. In this study, fluoride content in 18 commercial brands of bottled waters was investigated. Six samples from each batch of 18 Iranian commercial brands of bottled waters were supplied. The fluoride content of samples was analyzed by Fluoride Ion Selective Electrode. The mean ± SD fluoride content of the bottled waters was 0.202 ± 0.00152 mg/L with a range...

  20. A comparative assessment of fluoride concentration available in saliva using daily prescribed topical fluoride agents

    Science.gov (United States)

    Talwar, Manjit; Tewari, Amrit; Chawla, H. S.; Sachdev, Vinod

    2016-01-01

    Objective: To assess the availability of fluoride concentration in saliva following the use of fluoride mouthrinse and dentifrice. Materials and Methods: The experiment was carried out in 7–15 year-old school children of Chandigarh (n = 90). The children were nonfluoride users. Baseline saliva samples were collected. The subjects were exposed to two test agents, i.e., fluoride mouthrinse (0.05%, 225 ppm F) and dentifrice (1000 ppm F) for 7 days and on the day 8, saliva samples were collected over a 20 hrs period. Wash out period of 31/2 months was there before the subjects were exposed to the second test agent. Fluoride in saliva was estimated using fluoride ion-specific electrode. Written informed consent was taken. Statistical Analysis: Kolmogorov–Smirnov test was applied to test the normality of the variables. Mann–Whitney U-test was used to compare the fluoride concentration available in saliva at respective time intervals subsequent to use of the two test agents. Results: Fluoride concentration was elevated in saliva compared to baseline for both the test agents. Fluoride mouthrinse (0.05% sodium fluoride [NaF]) and dentifrice (1000 ppm monofluorophosphate [MFP]) showed a biphasic clearance. Peak in saliva occurred at 15 mins postuse. Night-time use resulted in higher concentration of fluoride in saliva compared to baseline. There was statistically significantly higher fluoride concentration available in saliva for the dentifrice at 5 hrs, 10 hrs, and 20 hrs postuse (P < 0.05). Conclusion: Subsequent to the use of NaF (0.05%) daily mouthrinse and MFP dentifrice (1000 ppm) the fluoride concentration in saliva remained elevated to a level of 0.12 ppm for mouthrinse and 0.14 ppm for dentifrice compared to baseline (0.03 ppm) up to 20 hrs postuse. The therapeutic window though not yet established but suggested is 0.1–1 ppm for prevention of demineralization, indicating that daily use of fluoride mouthrinse and dentifrice provides fluoride concentration in

  1. Global Measurements of Atmospheric Sulfuryl Fluoride

    Science.gov (United States)

    Mühle, J.; Harth, C. M.; Salameh, P.; Miller, B. R.; Weiss, R. F.; Porter, L. W.; Fraser, P. J.; Greally, B. R.; O'Doherty, S.

    2006-12-01

    Sulfuryl fluoride (SO2F2) is used increasingly as a fumigant, but information about its emissions to the atmosphere is limited. Its atmospheric fate and lifetime are uncertain, with hydrolysis in the basic surface waters of the oceans a likely dominant sink, and its roles as a greenhouse gas and as a sulfur source to the stratosphere are unknown. We present here the first results of two years of high-frequency high-precision in situ observations of sulfuryl fluoride in the AGAGE (Advanced Global Atmospheric Gases Experiment) global measurement program. At La Jolla, California, baseline conditions are rarely achieved, and pollution events of up to 1.7 ppb (the exposure limit is 5 ppm) from nearby structural fumigation are common. At the Mace Head, Ireland, and Cape Grim, Tasmania, AGAGE stations, baseline conditions are observed with mixing ratios at the beginning of 2005 of ~1.0 ppt and ~0.9 ppt, respectively. Measured growth rates at these stations are ~0.06 ppt per year and ~0.04 ppt per year, respectively. Using these preliminary results and assuming no significant emissions in the southern hemisphere, a simple 2-box model can be used to estimate the tropospheric lifetime of sulfuryl fluoride as about one and a half decades, which is substantially longer than previous industry estimates. The corresponding modeled sulfuryl fluoride flux to the troposphere is ~2 x 109 g per year. Based on these initial measurements, the current global warming contribution of sulfuryl fluoride is likely small. Although the lifetime of sulfuryl fluoride is longer than that of carbonyl sulfide, sulfuryl fluoride is likely less important as source of sulfur to the stratosphere, due to its low atmospheric mixing ratio.

  2. Caries inhibition by fluoride-releasing primers.

    Science.gov (United States)

    Kerber, L J; Donly, K J

    1993-10-01

    This study evaluated the caries inhibition of dentin primers with the addition of fluoride. Two standardized Class V preparations were placed in 20 molars, the gingival margin placed below the cementoenamel junction and the occlusal margin placed in enamel. Two dentin primers (Syntac and ScotchPrep) were placed in equal numbers of 20 preparations, according to manufacturer's instructions. Ammonium fluoride (10% by weight) was then added to these primers and they were placed in the remaining 20 preparations, opposing the non-fluoridated primer of the same system. All teeth were then restored with a non-fluoridated resin composite. All teeth were subjected to an artificial caries challenge (pH 4.2) for 5 days. Sections of 100 microns were obtained, photographed under polarized light microscopy, then demineralized areas were quantitated by digitization. Results demonstrated the mean areas (mm2 +/- S.D.) demineralization at 0.25 mm, 0.5 mm and 1.0 mm from the restoration margin to be: Syntac/fluoride (1.44 +/- 0.49, 1.68 +/- 0.54, 3.72 +/- 0.74); Syntac (1.99 +/- 0.58, 1.50 +/- 0.35, 2.98 +/- 1.26); ScotchPrep/fluoride (1.23 +/- 0.68, 1.55 +/- 0.64, 3.08 +/- 1.16); ScotchPrep (1.90 +/- 0.83, 1.71 +/- .038, 3.36 +/- 0.62). A paired t-test indicated primers with fluoride to demonstrate significantly less demineralization 0.25 mm from the restoration margin (P < 0.07). PMID:7880460

  3. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  4. Neutron Inelastic Scattering Study of Liquid Argon

    International Nuclear Information System (INIS)

    The inelastic scattering functions for liquid argon have been measured at 85.2 K. The coherent scattering function was obtained from a measurement on pure A-36 and the incoherent function was derived from the result obtained from the A-36 sample and the result obtained from a mixture of A-36 and A-40 for which the scattering is predominantly incoherent. The data, which are presented as smooth scattering functions at constant values of the wave vector transfer in the range 10 - 44/nm, are corrected for multiple scattering contributions and for resolution effects. Such corrections are shown to be essential in the derivation of reliable scattering functions from neutron scattering data. The incoherent data are compared to recent molecular dynamics results and the mean square displacement as a function of time is derived. The coherent data are compared to molecular dynamics results and also, briefly, to some recent theoretical models

  5. Large vessel sealing with the argon laser.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; Lyons, R; White, G; Klein, S R; Pizzurro, D; Abergel, R P; Dwyer, R M; Uitto, J

    1987-01-01

    This study compared the histology, biochemistry, and tensile strength of laser-welded and sutured canine venotomies, arteriotomies, and arteriovenous fistulas. Twelve animals had bilateral femoral vessels studied, with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralateral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks (four animals for each type of repair), and were evaluated histologically by hematoxylin and eosin, elastin, and trichrome stains; biochemically by the formation of [3H]hydroxyproline as an index of collagen synthesis; and mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms, or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welding may be an alternative to sutures for repair of large-diameter venotomies, arteriotomies, and arteriovenous fistulas, as healing is comparable to that seen with suture repairs up to 4 weeks postoperatively. PMID:3306233

  6. Vascular Welding Using The Argon Laser

    Science.gov (United States)

    White, Rodney A.; Donayre, Carlos; Kopchok, George; White, Geoffrey; Abergel, R. Patrick; Lyons, Richard; Klein, Stanley; Dwyer, Richard; Uitto, Jouni

    1987-03-01

    This study compared the histology, biochemistry, and tensile strength of laser welded and sutured canine venotomies, arteriotomies and arteriovenous fistulas. Bilateral femoral, carotid or jugular vessels were studied with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralatral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks for each type of repair and evaluated histologically by hematoxylineosin, elastin and trichrome stains, biochemically by the formation of [3H] hyaroxyproline as an index of collagen synthesis, ana mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welaing may be an alternative to sutures for repair of large diameter venotomies, arteriotomies and arteriovenous fistulas, as they heal comparable to suture repairs up to 4 weeks postoperatively.

  7. Ideas for future liquid Argon detectors

    International Nuclear Information System (INIS)

    We outline a strategy for future experiments on neutrino and astroparticle physics based on the use, at different detector mass scales (100 ton and 100 kton), of the liquid Argon Time Projection Chamber (LAr TPC) technique. The LAr TPC technology has great potentials for both cases with large degree of interplay between the two applications and a strong synergy. The ICARUS R and D programme has demonstrated that the technology is mature and that one can built a large (∼ 1 kton) LAr TPC. We believe that one can conceive and design a very large mass LAr TPC with a mass of 100 kton by employing a monolithic technology based on the use of industrial, large volume cryogenic tankers developed by the petro-chemical industry. We show a potential implementation of a large LAr TPC detector. Such a detector would be an ideal match for a Superbeam[New J. Phys. 4 (2002) 88 [arXiv:hep-ph/0208047

  8. Liquid-argon cylindrical pulsed ionization chamber

    International Nuclear Information System (INIS)

    A liquid-argon cylindrical ionization chamber with a working volume of 200 cm2 is described. The chamber anode is made of stainless steel in the form of a hollow cylinder 30 mm in diameter and 140 mm in length. A beryllium bronze wire in diameter of 0.1 mm and at a spacing of 1 mm is used for winding the chamber screen grid. The chamber cathode is a brass thin-walled cylinder having an internal diameter of 56 mm and a height of 156 mm. The cathode-grid gap is 10 mm, the cathode-case gap is 2 mm. A 0.5 l cooling bath filled with liquid nitrogen is used to refrigirate the chamber. The chamber is evacuated to about 10-5 mm Hg. The total concentration of electronegative impurities in argon does not exceed 6x10-9. Dependences of the chamber counting and amplitude responses, on the cathode voltage under irradiation with γ-quanta at energies of 0.898 MeV and 1.836 MeV are given. The value of the energy resolution was evaluated by differentiating the high-energy edge of the Compton spectrum. The total width at a peak half-height constitutes 5% for an electron energy of 1.612 MeV. To achieve better resolution of the chamber it is necessary to reduce preamplifier noises by three times, to increase the working gap of the chamber and decrease the grid-anode gap

  9. Thermodynamic data-base for metal fluorides

    International Nuclear Information System (INIS)

    This study is aimed at collecting useful data of thermodynamic properties of various metal fluorides. Many thermodynamic data for metal fluorides are needed for the effective development, but no report of data-base was published. Accordingly, the objective of this report is to rearrange systematically the existing thermodynamic data based on metal fluorides and is to use it as basic data for the development of pyrochemical process. The physicochemical properties of various metal fluorides and metals were collected from literature and such existing data base as HSC code, TAPP code, FACT code, JANAF table, NEA data-base, CRC handbook. As major contents of the thermodynamic data-base, the physicochemical properties such as formation energy, viscosity, density, vapor pressure, etc. were collected. Especially, some phase diagrams of eutectic molten fluorides are plotted and thermodynamic data of liquid metals are also compiled. In the future, the technical report is to be used as basic data for the development of the pyrochemical process which is being carried out as a long-term nuclear R and D project

  10. Thermodynamic data-base for metal fluorides

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Hyung; Lee, Byung Gik; Kang, Young Ho and others

    2001-05-01

    This study is aimed at collecting useful data of thermodynamic properties of various metal fluorides. Many thermodynamic data for metal fluorides are needed for the effective development, but no report of data-base was published. Accordingly, the objective of this report is to rearrange systematically the existing thermodynamic data based on metal fluorides and is to use it as basic data for the development of pyrochemical process. The physicochemical properties of various metal fluorides and metals were collected from literature and such existing data base as HSC code, TAPP code, FACT code, JANAF table, NEA data-base, CRC handbook. As major contents of the thermodynamic data-base, the physicochemical properties such as formation energy, viscosity, density, vapor pressure, etc. were collected. Especially, some phase diagrams of eutectic molten fluorides are plotted and thermodynamic data of liquid metals are also compiled. In the future, the technical report is to be used as basic data for the development of the pyrochemical process which is being carried out as a long-term nuclear R and D project.

  11. Emissions of fluorides from welding processes.

    Science.gov (United States)

    Szewczyńska, Małgorzata; Pągowska, Emilia; Pyrzyńska, Krystyna

    2015-11-01

    The levels of fluoride airborne particulates emitted from welding processes were investigated. They were sampled with the patented IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM), personal inhalable sampler for simultaneous collection of the inhalable and respirable size fractions. Ion chromatography with conductometric detection was used for quantitative analysis. The efficiency of fluoride extraction from the cellulose filter of the IOM sampler was examined using the standard sample of urban air particle matter SRM-1648a. The best results for extraction were obtained when water and the anionic surfactant N-Cetyl-N-N-N-trimethylammonium bromide (CTAB) were used in an ultrasonic bath. The limits of detection and quantification for the whole procedure were 8μg/L and 24μg/L, respectively. The linear range of calibration was 0.01-10mg/L, which corresponds to 0.0001-0.1mg of fluorides per m(3) in collection of a 20L air sample. The concentration of fluorides in the respirable fraction of collected air samples was in the range of 0.20-1.82mg/m(3), while the inhalable fraction contained 0.23-1.96mg/m(3) of fluorides during an eight-hour working day in the welding room. PMID:26574102

  12. The kinetics of fluoride uptake by synthetic hydroxyapatite

    Directory of Open Access Journals (Sweden)

    Takudzwa Gomwe

    2012-03-01

    Full Text Available The kinetics of fluoride uptake by synthetic hydroxyapatite from aqueous solution has been studied. Experiments involved exposing 0.1 g of synthetic hydroxyapatite to 5 cm3 of sodium fluoride solution in the concentration range 100-1000 ppm fluoride and determining fluoride concentration at regular time intervals with a fluoride ion-selective electrode. In all cases, uptake was found to follow pseudo-second order kinetics with correlation coefficients of at least 0.998; all systems equilibrated by 24 hours with equilibrium uptake values that varied with the initial fluoride concentration. The kinetic results differ from those previously reported for much lower concentrations of fluoride, but in the present case, the concentrations were of clinical relevance, as they are those used in fluoride-containing dental products. Further work is necessary to determine how well these findings model uptake by natural hydroxyapatite and hence the extent to which they might apply in vivo.

  13. Removing Fluoride Ions with Continously Fed Activated Alumina.

    Science.gov (United States)

    Wu, Yeun C.; Itemaking, Isara Cholapranee

    1979-01-01

    Discussed is the mathematical basis for determining fluoride removal during water treatment with activated alumina. The study indicates that decreasing particle size decreases the pore diffusion effect and increases fluoride removal. (AS)

  14. A simple and colorimetric fluoride receptor and its fluoride-responsive organogel

    International Nuclear Information System (INIS)

    In this paper, a new p-nitrophenylhydrozine-based anion receptor 1 containing cholesterol group had been designed and synthesized. It could selectively recognize fluoride among different anions tested with color changes from pale yellow to red for visual detection. Simultaneously, it could gel in cyclohexane, and the gel was also fluoride-responsive. When treated with TBAF (tetra-n-butylammonium fluoride), the gel could undergo gel–sol transition accompanied by color, morphology and surface changes. The binding mechanism had been investigated by UV–vis and 1HNMR (proton nuclear magnetic resonance spectra) titrations. From SEM (scanning electron microscope), SAXS (small-angle X-ray scattering), IR (Infrared Spectroscopy) and CA (contact angle) experiments, it was indicated that the addition of F− could destroy the molecule assembly of host 1 in the gel state, thus resulting in the gel-to-sol transition due to the binding site competition effect. To the best of our knowledge, this was the simplest fluoride-responsive organogel with high selectivity. Highlights: ► A novel kind receptor for selective recognition of fluoride had been designed. ► Its organogel was also fluoride-responsive. ► This is the simplest fluoride-responsive organogel with high selectivity.

  15. Parabens do not increase fluoride uptake by dental enamel

    OpenAIRE

    Vanessa Silva Tramontino; Daniela Labbate; Tabchoury, Cínthia Pereira Machado; Jaime Aparecido CURY

    2010-01-01

    Objective: To evaluate whether methylparaben and propylparaben, which present a similar chemical structure, increase fluoride uptake by demineralized dental enamel when present in buffered solutions. Methods: The study comprised an in vitro experiment using blocks of bovine dental enamel with artificial carious lesions. Enamel blocks were exposed to the following treatment (n=12): fluoride solution (200 ppm fluoride) - control; solution containing fluoride and 13 mM methylparaben; solution co...

  16. FLUORIDE: A REVIEW OF USE AND EFFECTS ON HEALTH

    Science.gov (United States)

    Kanduti, Domen; Sterbenk, Petra; Artnik, Barbara

    2016-01-01

    Introduction: Appropriate oral health care is fundamental for any individual’s health. Dental caries is still one of the major public health problems. The most effective way of caries prevention is the use of fluoride. Aim: The aim of our research was to review the literature about fluoride toxicity and to inform physicians, dentists and public health specialists whether fluoride use is expedient and safe. Methods: Data we used in our review were systematically searched and collected from web pages and documents published from different international institutions. Results: Fluoride occurs naturally in our environment but we consume it in small amounts. Exposure can occur through dietary intake, respiration and fluoride supplements. The most important factor for fluoride presence in alimentation is fluoridated water. Methods, which led to greater fluoride exposure and lowered caries prevalence, are considered to be one of the greatest accomplishments in the 20th century`s public dental health. During pregnancy, the placenta acts as a barrier. The fluoride, therefore, crosses the placenta in low concentrations. Fluoride can be transmitted through the plasma into the mother’s milk; however, the concentration is low. The most important action of fluoride is topical, when it is present in the saliva in the appropriate concentration. The most important effect of fluoride on caries incidence is through its role in the process of remineralization and demineralization of tooth enamel. Acute toxicity can occur after ingesting one or more doses of fluoride over a short time period which then leads to poisoning. Today, poisoning is mainly due to unsupervised ingestion of products for dental and oral hygiene and over-fluoridated water. Conclusion: Even though fluoride can be toxic in extremely high concentrations, it`s topical use is safe. The European Academy of Paediatric Dentistry (EAPD) recommends a preventive topical use of fluoride supplements because of their

  17. Argon laser induced changes to the carbonate content of enamel

    Energy Technology Data Exchange (ETDEWEB)

    Ziglo, M.J. [Orthodontic Graduate Program, Faculty of Medicine and Dentistry, University of Alberta, Private Practice, Regina, Saskatchewan (Canada); Nelson, A.E., E-mail: aenelson@dow.com [Department of Chemical and Materials Engineering, Faculty of Engineering, University of Alberta (Canada); Heo, G.; Major, P.W. [Orthodontic Graduate Program, Faculty of Medicine and Dentistry, University of Alberta (Canada)

    2009-05-15

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm{sup -2}) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  18. Argon laser induced changes to the carbonate content of enamel

    International Nuclear Information System (INIS)

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm-2) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  19. Pharmacokinetics of fluoride in toddlers after application of 5% sodium fluoride dental varnish.

    Science.gov (United States)

    Milgrom, Peter; Taves, Donald M; Kim, Amy S; Watson, Gene E; Horst, Jeremy A

    2014-09-01

    The prevalence of dental caries (tooth decay) among preschool children is increasing, driven partially by an earlier age of onset of carious lesions. The American Academy of Pediatrics recommends application of 5% sodium fluoride varnish at intervals increasing with caries risk status, as soon as teeth are present. However, the varnishes are marketed for treatment of tooth sensitivity and are regulated as medical devices rather than approved by the US Food and Drug Administration for prevention of dental caries (tooth decay). The objective of this research is to examine the safety of use in toddlers by characterizing the absorption and distribution profile of a currently marketed fluoride varnish. We measured urinary fluoride for 5 hours after application of fluoride varnish to teeth in 6 toddlers aged 12 to 15 months. Baseline levels were measured on a separate day. The urine was extracted from disposable diapers, measured by rapid diffusion, and extrapolated to plasma levels. The mean estimated plasma fluoride concentration was 13 μg/L (SD, 9 μg/L) during the baseline visit and 21 μg/L (SD, 8 μg/L) during the 5 hours after treatment. Mean estimated peak plasma fluoride after treatment was 57 μg/L (SD, 22 μg/L), and 20 μg/kg (SD, 4 μg/L) was retained on average. Retained fluoride was 253 times lower than the acute toxic dose of 5 mg/kg. Mean plasma fluoride after placement of varnish was within an SD of control levels. Occasional application of fluoride varnish following American Academy of Pediatrics guidance is safe for toddlers. PMID:25136045

  20. Probing the Reaction Mechanism of Aluminum/Poly(vinylidene fluoride) Composites.

    Science.gov (United States)

    DeLisio, Jeffery B; Hu, Xiuli; Wu, Tao; Egan, Garth C; Young, Gregory; Zachariah, Michael R

    2016-06-23

    Energetic thin films with high mass loadings of nanosized components have been recently fabricated using electrospray deposition. These films are composed of aluminum nanoparticles (nAl) homogeneously dispersed in an energetic fluoropolymer binder, poly(vinylidene fluoride) (PVDF). The nascent oxide shell of the nAl has been previously shown to undergo a preignition reaction (PIR) with fluoropolymers such as polytetrafluoroethylene (PTFE). This work examines the PIR between alumina and PVDF to further explain the reaction mechanism of the Al/PVDF system. Temperature jump (T-jump) ignition experiments in air, argon, and vacuum environments showed that the nAl is fluorinated by gas phase species due to a decrease in reactivity in a vacuum. Thermogravimetric analysis coupled with differential scanning calorimetry (TGA/DSC) was used to confirm the occurrence of a PIR, and gas phase products during the PIR and fluorination of nAl were investigated with temperature jump time-of-flight mass spectrometry (T-jump TOFMS). Results show a direct correlation between the amount of alumina in the PVDF film and the relative signal intensity of hydrogen fluoride release (HF). Although the PIR between alumina and PVDF plays an important role in the Al/PVDF reaction mechanism, burn speeds of Al/PVDF films containing additional pure alumina particles showed no burn speed enhancement. PMID:27228361

  1. Preparation of uranium ingots from double fluorides

    International Nuclear Information System (INIS)

    A simple method has been developed for the preparation of uranium double fluorides and has given a new impetus to the study of the reduction of these compounds with a view to obtaining very pure uranium ingots. This reduction can be carried out using calcium or magnesium as the reducing agent, this latter metal being very interesting from the practical point of view. A comparative study of the heat balances of the reduction processes for the double fluorides and for uranium tetrafluoride has shown that reduction of the double fluorides is possible. The exact experimental conditions for these reductions have been determined. Our study has shown in particular that the reduction of the double salt UF4, CaF2 by magnesium leads to the production of small (20 to 500 g) samples of high-purity uranium with a yield of 99 per cent. (author)

  2. Uranyl fluoride luminescence in acidic aqueous solutions

    International Nuclear Information System (INIS)

    Luminescence emission spectra and decay rates are reported for uranyl species in acidic aqueous solutions containing HF or added NaF. The longest luminescence lifetime, 0.269 ± 0.006 ms, was observed from uranyl in 1 M HF + 1 M HClO4 at 296 K and decreased with increasing temperature. Based on a luminescence dynamics model that assumes equilibrium among electronically excited uranyl fluoride species and free fluoride ion, this long lived uranyl luminescence in aqueous solution is attributed primarily to UO2F2. Studies on the effect of added LiNO3 or Na2WO4·2H2O showed relatively weak quenching of uranyl fluoride luminescence which suggests that high sensitivity determination of the UF6 content of WF6 gas should be feasible via uranyl luminescence analysis of hydrolyzed gas samples of impure WF6

  3. Spectroscopic characterization of Ho3+ ion-doped fluoride glass

    International Nuclear Information System (INIS)

    Among the new optical materials available, fluoride glass, which has an extended transmission window, is emerging as an important material for use in optical fibers, lasers, sensors, etc. Here, we analyze the spectroscopic properties of Ho3+ ions in a fluoroindate glass based on absorption measurements. Ho3+-doped fluoroindate glass with the composition (40 - x)InF3-20SrF2-20ZnF2-16BaF2-2GdF3-2NaF-xHoF3, x = 1.0, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0, 8.0 and 9.0 mol%, was prepared under an argon atmosphere. Absorption spectra in the range 300-2200 nm were then obtained. The experimental oscillator strength f Exp. was calculated from the areas under absorption bands. Using Judd-Ofelt theory and least-squares fitting, the phenomenological intensity parameter Ω λ (λ = 2, 4, 6) and the theoretical oscillator strength f Cal. were calculated. To evaluate potential applications and to analyze the properties of Ho3+ ions in these host glasses, the following spectroscopy parameters were calculated: the transition probability between multiplets A JJ', the branching ratio β JJ', the radiative lifetime τ R, the peak cross-section for stimulated emission σ p, and the emitting-level multiphonon rate W NR for each band. The results were compared with those reported in the literature for similar glasses of the same concentration

  4. Effect of titanium tetrafluoride, amine fluoride and fluoride varnish on enamel erosion in vitro

    OpenAIRE

    Vieira, A; Ruben, JL; Huysmans, MCDNJM

    2005-01-01

    This study aimed at evaluating the effect of 1 and 4% titanium tetrafluoride (TiF4) gels, amine fluoride (AmF) 1 and 0.25% and a fluoride varnish (FP) on the prevention of dental erosion. Two experimental groups served as controls, one with no pretreatment and another one pre-treated with a fluoride-free varnish (FP-blanco). Dental erosion was modelled using bovine enamel samples submitted to alternate cycles of acid exposure in citric acid and remineralization in artificial saliva. Calcium l...

  5. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated...

  6. Cancer incidence and mortality in workers exposed to fluoride

    DEFF Research Database (Denmark)

    Grandjean, P; Olsen, J H; Jensen, O M; Juel, K

    1992-01-01

    Although a recent bioassay showed increased frequency of bone cancer in rats with high oral intake of fluoride, the data are reported as equivocal evidence of carcinogenicity. In humans, occupational fluoride exposure may cause skeletal fluorosis, and our earlier follow-up of fluoride...

  7. Coprecipitation of iron and silver with barium fluoride

    International Nuclear Information System (INIS)

    Distribution of trace contaminants of iron and silver at coprecipitation of barium fluoride is studied in present work. It is defined that iron almost completely coprecipitated with barium fluoride in wide range of ph 5.5-12. Silver coprecipitated with barium fluoride in ph range 4-7. The value of coprecipitation varies from 94% to 100%.

  8. Plasma processing of fluoride solutions of refractory rare metals

    Energy Technology Data Exchange (ETDEWEB)

    Gutsol, A.F. [Institute of Chemistry and Technology of Less-Common Elements and Raw Materials, Murmanskaya oblast` (Russian Federation)

    1995-09-01

    Features of plasma processing of fluoride solutions of refractory metals were studied. It was shown that pyrohydrolysis of niobium, tantalum, and titanium fluorides occurs in the gas phase, thus providing fine oxide powders. The pyrohydrolysis of low-volatility zirconium fluoride occurs in the solid phase, yielding oxide particles corresponding to the size of initial droplets.

  9. Onderzoek naar de bepaling van fluoride in een doorstroomsysteem

    NARCIS (Netherlands)

    Neele J; Nagtegaal-Wouterse GWM; Reijnders HFR

    1989-01-01

    Een snelle methode voor de bepaling van fluoride in een doorstroomsysteem met potentiometrische detectie en een lage onderste analysegrens is ontwikkeld. De mate waarin fluoride uit fluoride-verbindingen wordt vrijgemaakt door complexvormende stoffen is gevolgd om vast te stellen hoeveel tijd hierv

  10. Synthesis of reagents for fluoride technologies

    Institute of Scientific and Technical Information of China (English)

    Gordienko; P.; S.; Kolzunov; V.; A.; Dostovalov; V.; A.; Kaidalova; T.; A.

    2005-01-01

    Growing demand for fluorinating reagents to be used in rare-metal industry has stimulated conducting research in the field of production for these reagents. That is why the fluorinating reagents production has recently formed an independent segment of industry. Main industrial fluorinating reagents include hydrofluoric acid, anhydrous hydrogen fluoride, technical ammonium hydrodifluoride, fluorosilicic acid and its salts. To produce technical etching acid, fluor-spar with calcium fluoride content at least 92% is used in most cases. To produce anhydrous hydrogen fluoride, fluor-spar with calcium fluoride content 96 %-97 % is necessary. The fluorine-containing raw materials refinement from silica by means of flotation makes the fluorinating reagents production substantially more expensive. In this work we have attempted to process unconcentrated raw materials by fluorine removal in the form of volatile silicon tetrafluoride. In this process silicon tetrafluoride was recovered by liquid ammonia with subsequent hydrolysis of the formed ammonia hexafluorosilicate. Hydrolysis occurred according to the reaction:(NH4)2 SiF6 + 4NH3 + 2 H2O= 6NH4F+ SiO2 The products of the ammonia hexafluorosilicate hydrolysis included ammonia fluoride and amorphous silica gel ("white soot") as by-product. This "white soot" was of high purity-with main component content 99.95% and total admixture content 0.05%. Silica gel is a superfine material with specific surface of 267.6 m2/g and is recommended as filler in the production of rubber, plastics and for other applications.Ammonia fluoride was transformed into ammonia hydrodifluoride (main processing product) according to the reaction:2NH4F→NH3+NH4 HF2 It was stated that the NH4F: NH4 HF2 ratio depends on boiling point temperature-with its increase the ammonia hydrofluoride concentration in solution increases as well.

  11. LArGe - A liquid argon scintillation veto for GERDA

    OpenAIRE

    Heisel, M.(Max-Planck-Institut für Kernphysik, Heidelberg, Germany)

    2011-01-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the Gerda experiment. Gerda searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used...

  12. Practical reactor production of {sup 41}Ar from argon clathrate

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, J.R. E-mail: jmercer@pharmacy.ualberta.ca; Duke, M.J.M.; McQuarrie, S.A

    2000-06-01

    The radionuclide {sup 41}Ar has many ideal properties as a gas flow tracer. However, the modest cross-section of {sup 40}Ar for thermal neutron activation makes preparation of suitable activities of {sup 41}Ar technically difficult particularly for low flux reactors. Argon can however be trapped in a molecular complex called a clathrate that can then be irradiated. We prepared argon clathrate and explored its irradiation and stability characteristics. Argon clathrate can be used to provide gigabecquerel quantities of {sup 41}Ar even with low power reactors.

  13. Membrane separation processes for argon plasma gas recovery

    OpenAIRE

    Harlacher, Thomas

    2014-01-01

    A mixture of argon and hydrogen is used as plasma gas in a thermal plasma synthesis for the production of silicon carbide. Next to argon and hydrogen, the exhaust gas of the ceramic synthesis contains carbon monoxide. Since argon is an expensive gas, the plasma gas needs to be recycled. For this purpose, the carbon monoxide has to be removed from the exhaust gas. The applicability of a membrane based gas separation process for this separation task was investigated in this study. A process rou...

  14. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.; Hansen, Jens Leonhart; Sørensen, H.

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...... studied. This proves that the gas/solid difference for argon predicted in recent stopping-power tabulations is significantly overestimated. With high-order Z1 correction terms included in the theoretical description, calculated shell corrections based on the Lindhard-Scharff model are in good agreement...

  15. Reconstructing temporal variation of fluoride uptake in eastern grey kangaroos (Macropus giganteus) from a high-fluoride area by analysis of fluoride distribution in dentine.

    Science.gov (United States)

    Kierdorf, Horst; Rhede, Dieter; Death, Clare; Hufschmid, Jasmin; Kierdorf, Uwe

    2016-04-01

    Trace element profiling in the incrementally formed dentine of mammalian teeth can be applied to reconstruct temporal variation of incorporation of these elements into the tissue. Using an electron microprobe, this study analysed fluoride distribution in dentine of first and third mandibular molars of free-ranging eastern grey kangaroos inhabiting a high-fluoride area, to assess temporal variation in fluoride uptake of the animals. Fluoride content in the early-formed dentine of first molars was significantly lower than in the late-formed dentine of these teeth, and was also lower than in both, the early and the late-formed dentine of third molars. As early dentine formation in M1 takes place prior to weaning, this finding indicates a lower dentinal fluoride uptake during the pre-weaning compared to the post-weaning period. This is hypothetically attributed to the action of a partial barrier to fluoride transfer from blood to milk in lactating females and a low bioavailability of fluoride ingested together with milk. Another factor contributing to lower plasma fluoride levels in juveniles compared to adults is the rapid clearance of fluoride from blood plasma in the former due to their intense skeletal growth. The combined action of these mechanisms is considered to explain why in kangaroos from high-fluoride areas, the (early-formed) first molars are not affected by dental fluorosis while the (later-formed) third and fourth molars regularly exhibit marked to severe fluorotic lesions. PMID:26736058

  16. Micro-determination of fluoride by means of metallic sodium fusion and using fluoride-sensitive electrode.

    OpenAIRE

    Roy J; Rane S; Ghani A; Chaudhury C

    1993-01-01

    A simple and accurate method to determine the content of fluoride in non-volatile organofluoro compounds or in biological samples has been developed. The method includes the metallic sodium fusion followed by quantitative estimation of fluoride using fluoride-sensitive electrode.

  17. Some electronic and magnetic properties of Fluoride ion in Fluoride structure nanocrystals

    Science.gov (United States)

    Imtani, Ali Nasir

    2012-01-01

    We have investigated the effects of the environment potential around Fluoride ion on some important electronic and magnetic properties such as dipole polarisability, moment of oscillator strengths S(k) and magnetic susceptibility. The theoretical procedure is based on the variational-perturbation theory with two parameter trial functions incorporated in an ionic model. We estimate these properties in four cases for Fluoride ion; free ion, ion under different potentials, ion in the crystals and ion in nanocrystal, CdF2, CaF2, PbF2, SrF2 and BaF2. Our results indicate that these properties vary with ion environments and the free state of Fluoride ion has higher values and there is linearity behaviour of these properties with lattice constant. For Fluoride ion in nanocrystal, we have found that there is an extra parameter that can also affect the dipole polarisability, the number of ions in the structure.

  18. Comparative evaluation of fluoride release from PRG-composites and compomer on application of topical fluoride: An in-vitro study

    Directory of Open Access Journals (Sweden)

    Dhull K

    2009-03-01

    Full Text Available Aims and Objective: To determine the fluoride release from Giomer and Compomer, using different topical fluoride regimes, and to compare the amount of fluoride release from giomer with that of compomer. Materials and Method: Forty-eight specimens of each giomer and compomer were divided into four treatment groups, namely, control group, fluoridated dentifrice (500 ppm once daily group, fluoridated dentifrice (500 ppm twice daily group, fluoridated dentifrice (500 ppm once daily + fluoridated mouthwash (225 ppm group. Each specimen was suspended in demineralizing solution for six hours and remineralizing solution for 18 hours. Fluoride release was measured in both the demineralizing solution and remineralizing solution daily for seven days. Total daily fluoride release for each specimen was calculated by adding the amount released in the demineralizing solution to that released in remineralizing solution. Results and Conclusion: The fluoride release (ppm was found to be more in Giomer when compared to Compomer. The fluoride released from Giomer and Compomer was significantly greater in the acidic demineralizing solution than in the neutral remineralizing solution. It was found that increasing fluoride exposure significantly increased fluoride release from the giomer and compomer. It was found that the fluoride release from the subgroups of giomer and compomer was in the following order: fluoridated dentifrice twice daily > fluoridated dentifrice once daily + fluoridated mouthwash > fluoridated dentifrice once daily > control group. It was found that the giomer showed a greater fluoride uptake than the compomer.

  19. Argon laser treatment of urethral stricture and vesical neck contracture.

    Science.gov (United States)

    Adkins, W C

    1988-01-01

    The physical characteristics of the argon laser wavelength allow a precise incision with excellent hemostasis and negligible heating of adjacent tissues resulting in less scarring. These qualities are used to advantage in the treatment of strictures. The argon laser was used to perform 13 internal urethrotomies and ten vesical neck incisions. The operative method used is similar to optical internal urethrotomy. The argon probe incises hemostatically, reducing the need for extensive fulguration of tissues at the operative site and thereby reducing the tendency for more scar tissue to form and compromise the operation. The same hemostasis reduces the need for postoperative indwelling urethral catheterization. Utility of the argon device in most instances allows treatment to be conducted on an outpatient basis without general anesthesia and without use of postoperative urethral catheters, yielding an effective, cost-saving therapy. PMID:3210887

  20. Evidence of electric breakdown induced by bubbles in liquid argon

    CERN Document Server

    Bay, F; Murphy, S; Resnati, F; Rubbia, A; Sergiampietri, F; Wu, S

    2014-01-01

    We report on the results of a high voltage test in liquid argon in order to measure its dielectric rigidity. Under stable conditions and below the boiling point, liquid argon was found to sustain a uniform electric field of 100 kV/cm, applied in a region of 20 cm$^2$ area across 1 cm thick gap. When the liquid is boiling, breakdowns may occur at electric fields as low as 40 kV/cm. This test is one of the R&D efforts towards the Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER) as proposed Liquid Argon Time Projection Chamber (LAr TPC) for the LBNO observatory for neutrino physics, astrophysics and nucleon decay searches.

  1. Excitation temperatures of atmospheric argon in dielectric barrier discharges

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yu; Wen Xiaohui; Yang Weihong [CAS Key Laboratory of Basic Plasma Physics and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2007-08-15

    A method for the determination of excitation temperatures based on optical emission spectroscopy and Fermi-Dirac distribution was set up and experiments were performed on atmospheric argon dielectric barrier discharges. Local thermodynamic equilibrium was proved to exist in the discharge and the validity of Boltzmann distribution is discussed. The main aim of this paper is to obtain the temperatures of atmospheric Ar II as a function of the discharge voltage, discharge frequency, argon flow rate and the argon fraction. It was found that the excitation temperatures are in the range 3800-4950 K. Besides, an increase in the argon flow rate resulting in a slight growth of the temperature and the add-in of air leading to the decrease in temperature was observed.

  2. The Effects of Dissolved Methane upon Liquid Argon Scintillation Light

    CERN Document Server

    Jones, B J P; Back, H O; Collin, G; Conrad, J M; Greene, A; Katori, T; Pordes, S; Toups, M

    2013-01-01

    In this paper we report on measurements of the effects of dissolved methane upon argon scintillation light. We monitor the light yield from an alpha source held 20 cm from a cryogenic photomultiplier tube (PMT) assembly as methane is injected into a high-purity liquid argon volume. We observe significant suppression of the scintillation light yield by dissolved methane at the 10 part per billion (ppb) level. By examining the late scintillation light time constant, we determine that this loss is caused by an absorption process and also see some evidence of methane-induced scintillation quenching at higher concentrations (50-100 ppb). Using a second PMT assembly we look for visible re-emission features from the dissolved methane which have been reported in gas-phase argon methane mixtures, and we find no evidence of visible re-emission from liquid-phase argon methane mixtures at concentrations between 10 ppb and 0.1%.

  3. The ATLAS Liquid Argon Calorimeter Construction, Integration, Commissioning

    CERN Document Server

    Aleksa, Martin

    2006-01-01

    The ATLAS liquid argon (LAr) calorimeter system consists of an electromagnetic barrel calorimeter and two end caps with electromagnetic, hadronic and forward calorimeters. The liquid argon sampling technique, with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the end cap (EMEC). The hadronic end cap calorimeter (HEC) uses a copper-liquid argon sampling technique with flat plate geometry and is subdivided in depth in two wheels per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules employing cylindrical electrodes with thin liquid argon gaps. The construction of the full calorimeter system is complete since mid-2004. Production modules constructed in the home institutes were integrated into wheels at CERN in 2003-2004, and inserted into the three cryostats. They passed their first complete cold test before the lowering into the ATLAS cavern. Results of quality checks (e.g. electrical, mechanical, ...) performed on all the 190304 read...

  4. Manufacture of high purity low arsenic anhydrous hydrogen fluoride

    International Nuclear Information System (INIS)

    A process for manufacturing anhydrous hydrogen fluoride with reduced levels of arsenic impurity from arsenic contaminated anhydrous hydrogen fluoride is described which comprises: (a) contacting the anhydrous hydrogen fluoride with an effective amount of hydrogen peroxide to oxidize the arsenic impurity in the presence of a catalyst which comprises a catalytic amount of (i) molybdenum or an inorganic molybdenum compound and (ii) a phosphate compound, at a temperature and for a period of time sufficient to oxidize volatile trivalent arsenic impurities in the anhydrous hydrogen fluoride to non-volatile pentavalent arsenic compounds, and (b) distilling the resulting mixture and recovering anhydrous hydrogen fluoride with reduced levels of arsenic impurity

  5. Fluoride: a risk factor for inflammatory bowel disease?

    Science.gov (United States)

    Follin-Arbelet, Benoit; Moum, Bjørn

    2016-09-01

    Although the association between inflammatory bowel disease (IBD) and oral hygiene has been noticed before, there has been little research on prolonged fluoride exposure as a possible risk factor. In the presented cases, exposure to fluoride seems indirectly associated with higher incidence of IBD. Fluoride toxicology and epidemiology documents frequent unspecific chronic gastrointestinal symptoms and intestinal inflammation. Efflux genes that confer resistance to environmental fluoride may select for IBD associated gut microbiota and therefore be involved in the pathogenesis. Together these multidisciplinary results argue for further investigation on the hypothesis of fluoride as a risk factor for IBD. PMID:27199224

  6. Fluoride inhibition of proton-translocating ATPases of oral bacteria.

    OpenAIRE

    Sutton, S V; Bender, G R; Marquis, R E

    1987-01-01

    The ATPases of isolated membranes of lactic acid bacteria were found to be inhibited by fluoride in a complex manner. Among the enzymes tested, that of Streptococcus mutans GS-5 was the most sensitive to fluoride, and the initial rate of hydrolysis of ATP was reduced 50% by approximately 3 mM fluoride. The enzyme of Lactobacillus casei ATCC 4646 was the most resistant, and about 25 mM fluoride was required for 50% inhibition. The response to fluoride appeared to involve reversible, noncompeti...

  7. Oral Fluoride Including Drinking Water in Prevention of Tooth Decay

    OpenAIRE

    Vitoria I

    2015-01-01

    Herein we present a review of the role of oral fluoride in the prevention of tooth decay, together with updated recommendations on fluoride supplements. Fluoridation of public drinking water is still considered effective, but the recommended level of fluoride is now 0.7 mg/L, compared with the previously recommended range of 0.7-1.2 mg/L. Oral fluoride supplements are currently not restricted to the children at high risk for tooth decay, but recommended initiate at 6 months&nbs...

  8. Size Determination of Argon Clusters from a Rayleigh Scattering Experiment

    Institute of Scientific and Technical Information of China (English)

    LEI An-Le; ZHAI Hua-Jin; LIU Bing-Chen; LI Zhong; NI Guo-Yuan; XU Zhi-Zhan

    2000-01-01

    Argon clusters are produced in the process of adiabatic expansion of a high backing pressure gas into vacuum through a nozzle. The cluster size is determined by a Rayleigh scattering measurement. The scattered signal measured is proportional to the 2.78th power of gas stagnation pressure. The average cluster sizes vary from 100 to more than 12000 atoms/cluster with the argon gas backing pressures ranging between 3 to 45 atm.

  9. A purity monitoring system for liquid argon calorimeters

    International Nuclear Information System (INIS)

    For liquid argon calorimeters electronegative impurities dissolved in the medium degrade the detector response and deteriorate the energy resolution, especially at high energies. A concept for a purity monitoring system for liquid argon calorimeters has been developed and is presented here. Special combined monitors of 241Am- and 207Bi-cells are used to monitor the concentration of impurities. The working principle as well as results from test measurements are discussed

  10. Studies of Electron Avalanche Behavior in Liquid Argon

    OpenAIRE

    Kim, J.G.; Dardin, S. M.; Jackson, K.H.; Kadel, R. W.(Lawrence Berkeley National Laboratory and University of California, 94720, Berkeley, California, USA); Kadyk, J. A.; Peskov, V.; Wenzel, W. A.

    2002-01-01

    Electron avalanching in liquid argon is being studied as a function of voltage, pressure, radiation intensity, and the concentrations of certain additives, especially xenon. The avalanches produced in an intense electric field at the tip of a tungsten needle are initiated by ionization from a moveable americium (241Am) gamma ray source. Photons from xenon excimers are detected as photomultiplier signals in coincidence with the current pulse from the needle. In pure liquid argon the avalanche ...

  11. Pulse shape discrimination studies in a liquid Argon scintillation detector

    OpenAIRE

    Pollmann, T.

    2007-01-01

    Liquid rare gases have been gaining popularity as detector media in rare event searches, especially dark matter experiments, and one factor driving their adoption is the possibility to recognise different types of ionizing radiation by the pulse shapes they evoke. This work on pulse shape discrimination in a liquid argon scintillation detector was done in the framework of the GERDA experiment, where liquid argon scintillation signals may be used for background suppression purposes. Liquid arg...

  12. RF-ARGON PLASMA INDUCED SURFACE MODIFICATION OF PAPER

    OpenAIRE

    HALIL TURGUT SAHIN

    2008-01-01

    The radio frequency (RF) argon plasma induced surface modification of paper revealed novel surface characteristics and substantially changed surface topography. It was found that RF-argon glow discharge affects surface properties resulting in photo-degradation and chain-scission mechanism on paper network structure. High-power and extended treatment time caused increasing elemental carbon, while decreasing the oxygen concentration on paper surface. However, increased hydroxyls and the creatio...

  13. Actinide measurements by AMS using fluoride matrices

    Science.gov (United States)

    Cornett, R. J.; Kazi, Z. H.; Zhao, X.-L.; Chartrand, M. G.; Charles, R. J.; Kieser, W. E.

    2015-10-01

    Actinides can be measured by alpha spectroscopy (AS), mass spectroscopy or accelerator mass spectrometry (AMS). We tested a simple method to separate Pu and Am isotopes from the sample matrix using a single extraction chromatography column. The actinides in the column eluent were then measured by AS or AMS using a fluoride target matrix. Pu and Am were coprecipitated with NdF3. The strongest AMS beams of Pu and Am were produced when there was a large excess of fluoride donor atoms in the target and the NdF3 precipitates were diluted about 6-8 fold with PbF2. The measured concentrations of 239,240Pu and 241Am agreed with the concentrations in standards of known activity and with two IAEA certified reference materials. Measurements of 239,240Pu and 241Am made at A.E. Lalonde AMS Laboratory agree, within their statistical uncertainty, with independent measurements made using the IsoTrace AMS system. This work demonstrated that fluoride targets can produce reliable beams of actinide anions and that the measurement of actinides using fluorides agree with published values in certified reference materials.

  14. THE DEVELOPMENT OF AN INDIGENOUS FLUORIDE FILTER

    Science.gov (United States)

    Given that an essential component of the design is that it can be adapted for use throughout the world, the potential media investigated are those available in the regions containing fluoride contaminated groundwater. From the literature, wood charcoal, bone char, laterite and...

  15. Total Fluoride Intake by Children from a Tropical Brazilian City.

    Science.gov (United States)

    Lima, Carolina V; Cury, Jaime A; Vale, Glauber C; Lima, Marina D M; Moura, Lúcia de Fátima A D; Moura, Marcoeli Silva de

    2015-01-01

    The main sources of fluoride intake by children are fluoridated water and toothpaste. Little has been studied regarding fluoride intake from these sources in regions with tropical climates and high temperatures throughout the year. This study aimed to determine the amount of fluoride ingested from diet and tooth brushing by children who live in a city with a tropical climate. Sixty-seven children from Teresina, Piauí, Brazil, took part in this study. The city's water supply was optimally fluoridated. The duplicate-diet method was used to determine the fluoride intake from diet. The intake of fluoride from dentifrice was determined by subtracting the amount of fluoride placed on the toothbrush and that recovered after brushing. The concentration of fluoride was measured using an ion-specific electrode and is expressed as milligrams/kilogram of body weight/day. The mean (±SD) total amount was 0.071 ± 0.036 mg F/kg body weight/day, and the relative contributions of diet and toothpaste were 0.025 ± 0.010 and 0.046 ± 0.035, respectively. The factors associated with fluoride intake from toothpaste were: use of children's toothpaste (p = 0.003), use of large amounts of toothpaste (p fluoride ingested by most children who live in a Brazilian city with a tropical climate is considered safe in terms of the risk of dental fluorosis. PMID:26655142

  16. Estimated Fluoride Doses from Toothpastes Should be Based on Total Soluble Fluoride

    Directory of Open Access Journals (Sweden)

    Jaime A. Cury

    2013-11-01

    Full Text Available The fluoride dose ingested by young children may be overestimated if based on levels of total fluoride (TF rather than levels of bioavailable fluoride (total soluble fluoride—TSF in toothpaste. The aim of the present study was to compare doses of fluoride intake based on TF and TSF. Fluoride intake in 158 Brazilian children aged three and four years was determined after tooth brushing with their usual toothpaste (either family toothpaste (n = 80 or children’s toothpaste (n = 78. The estimated dose (mg F/day/Kg of body weight of TF or TSF ingested was calculated from the chemical analysis of the toothpastes. Although the ingested dose of TF from the family toothpastes was higher than that from the children’s toothpastes (0.074 ± 0.007 and 0.039 ± 0.003 mg F/day/Kg, respectively; p 0.05. The fluoride dose ingested by children from toothpastes may be overestimated if based on the TF of the product. This finding suggests that the ingested dose should be calculated based on TSF. Dose of TSF ingested by children is similar whether family or children’s toothpaste is used.

  17. Estimation of atmospheric fluoride by limed filter papers

    International Nuclear Information System (INIS)

    The limed filter paper method of static sampling of atmospheric fluoride is reviewed in this report. Use of the technique, in conjunction with precise measurement of the absorbed fluoride and calibration with dynamic air sampling techniques, to estimate atmospheric fluoride levels, is considered to give only qualitative data (± 50%). The limed filter paper method is site specific due to variations in meteorological conditions. Its main value is to indicate seasonal and annual trends in fluoride exposure of vegetation. Subject to these considerations, the lower and upper limits of atmospheric fluoride exposure and the applicability to atmospheric fluoride estimation under routine or emergency fluoride release conditions are discussed, with special emphasis on the limiting factors

  18. A study of fluoride groundwater occurrence in Nathenje, Lilongwe, Malawi

    Science.gov (United States)

    Msonda, K. W. M.; Masamba, W. R. L.; Fabiano, E.

    A study was carried out to determine fluoride concentration in groundwaters of Nathenje area situated in Lilongwe District in the central region of Malawi. Water samples were collected from 176 boreholes and shallow wells during different months in 2001 and 2002. Samples were then analysed for fluoride by using a fluoride electrode and an ion selective meter. The results showed that fluoride concentrations for the rainy season varied from part of Nathenje had high fluoride concentration of between 2 and 7.02 mg/l and these high fluoride values seemed to extend eastwards beyond the boundary of the study area. However, the southern and western parts had dental fluorosis in areas where the fluoride concentration was high.

  19. FLUORIDE CONTENT OF COMMERCIALLY AVAILABLE SOY MILK PRODUCTS IN THAILAND.

    Science.gov (United States)

    Rirattanapong, Opas; Rirattanapong, Praphasri

    2016-01-01

    Abstract. In Thailand, the consumption of soy milk products is common but there is limited data about their fluoride content. The purpose of this study was to es- timate the fluoride content of soy milk products available in Thailand. Fluoride content was determined for 76 brands of soy milk using a F-ion-specific electrode. The fluoride concentrations ranged from 0.01 to 3.78 μg/ml. The fluoride content was not related to sugar content, soy bean content or the sterilization process. Among 3 brands of soy milk containing tea powder extract, the fluoride content was high (1.25 to 3.78 μg/ml). Most brands of soy milk tested in our study had fluoride content below the optimal daily intake but brands containing tea powder extract if consumed by children may increase their risk for fluorosis. PMID:27086437

  20. Energy resolution for α-particles in doped liquid argon

    International Nuclear Information System (INIS)

    The report describes experiments on the effect of allene doped in liquid argon. In the case of doped argon, a large amount of charge is obtained even at low electric fields and the measured charge increases with the field gradually. This can be explained as follows; part of deposited energy which does not form charge in pure argon contributes to charge signal in doped argon through scintillation photons which ionize allene molecules. The main factors determining the energy resolution for α-particles are considered to be (1) fluctuation in the number of produced ion-electron pairs as expressed by the Fano factor, (2) fluctuation in recombination process, (3) fluctuation in photoionization, (4) fluctuation due to the condition of radioactive source and surface of electrodes, (5) fluctuation in geometrical efficiency due to the range and emission angle of α-particles in liquid argon, and (6) electronic noise of amplifier. The factors (1) and (3) can be neglected because of a large number of associated electrons or photons. In pure liquid argon, the factor (2) may be a cause of bad resolution since the fraction of the produced ion-electron paris which do not recombine is small and the photoionization process never occurs for photons emitted through recombination. (N.K.)

  1. Power Consideration for Pulsed Discharges in Potassium Seeded Argon

    Institute of Scientific and Technical Information of China (English)

    XIA Sheng-Guo; HE Jun-Jia; LIU Ke-Fu

    2007-01-01

    Minimization of energy consumed in plasma generation is critical for applications, in which a large volume of plasmas is needed. We suggest that a high electron density atmospheric pressure plasmas can be generated by pulsed discharges in potassium seeded argon at an elevated temperature with a very small power input. The ionization efficiency and power budget of pulsed discharges in such plasmas are analytically studied. The results show that ionization efficiency of argon, especially at small reduced electric field E/N (the ratio of the electric field to the gas number density), is improved effectively in the presence of small amount of potassium additives. Power input of pulsed discharge to sustain a prescribed average level of ionization in potassium seeded argon is three orders of magnitude lower than that in pure argon. Further, unlike in pure argon, it is found that very short high-voltage pulses with very high repetition rates are unnecessary in potassium seeded argon. A pulse with 100ns of pulse duration, 5kHz of repetition rate, and 2Td (1 Td = 1 ×10-21 Vm2) of E/N is enough to sustain an electron density of 10l9m-3 in 1 atm 1500 K Ar+0.1% K mixture, with a very small power input of about 0.08 × 104 W/m3.

  2. Water fluoridation in 40 Brazilian cities: 7 year analysis

    Directory of Open Access Journals (Sweden)

    Suzely Adas Saliba MOIMAZ

    2013-01-01

    Full Text Available Objectives Fluoride levels in the public water supplies of 40 Brazilian cities were analyzed and classified on the basis of risk/benefit balance. Material and Methods Samples were collected monthly over a seven-year period from three sites for each water supply source. The samples were analyzed in duplicate in the laboratory of the Center for Research in Public Health - UNESP using an ion analyzer coupled to a fluoride-specific electrode. Results A total of 19,533 samples were analyzed, of which 18,847 were artificially fluoridated and 686 were not artificially fluoridated. In samples from cities performing water fluoridation, 51.57% (n=9,720 had fluoride levels in the range of 0.55 to 0.84 mg F/L; 30.53% (n=5,754 were below 0.55 mg F/L and 17.90% (n=3,373 were above 0.84 mg F/L (maximum concentration=6.96 mg F/L. Most of the cities performing fluoridation that had a majority of samples with fluoride levels above the recommended parameter had deep wells and more than one source of water supply. There was some variability in the fluoride levels of samples from the same site and between collection sites in the same city. Conclusions The majority of samples from cities performing fluoridation had fluoride levels within the range that provides the best combination of risks and benefits, minimizing the risk of dental fluorosis while preventing dental caries. The conduction of studies about water distribution systems is suggested in cities with high natural fluoride concentrations in order to optimize the use of natural fluoride for fluoridation costs and avoid the risk of dental fluorosis.

  3. Effects of fluoridated milk on root dentin remineralization.

    Directory of Open Access Journals (Sweden)

    Wolfgang H Arnold

    Full Text Available The prevalence of root caries is increasing with greater life expectancy and number of retained teeth. Therefore, new preventive strategies should be developed to reduce the prevalence of root caries. The aim of this study was to investigate the effects of fluoridated milk on the remineralization of root dentin and to compare these effects to those of sodium fluoride (NaF application without milk.Thirty extracted human molars were divided into 6 groups, and the root cementum was removed from each tooth. The dentin surface was demineralized and then incubated with one of the following six solutions: Sodium chloride NaCl, artificial saliva, milk, milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Serial sections were cut through the lesions and investigated with polarized light microscopy and quantitative morphometry, scanning electron microscopy (SEM and energy-dispersive X-ray spectroscopy (EDS. The data were statistically evaluated using a one-way ANOVA for multiple comparisons.The depth of the lesion decreased with increasing fluoride concentration and was the smallest after incubation with artificial saliva+10 ppm fluoride. SEM analysis revealed a clearly demarcated superficial remineralized zone after incubation with milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Ca content in this zone increased with increasing fluoride content and was highest after artificial saliva+10 ppm fluoride incubation. In the artificial saliva+10 ppm fluoride group, an additional crystalline layer was present on top of the lesion that contained elevated levels of F and Ca.Incubation of root dentin with fluoridated milk showed a clear effect on root dentin remineralization, and incubation with NaF dissolved in artificial saliva demonstrated a stronger effect.

  4. Electron densities and energies of a guided argon streamer in argon and air environments

    International Nuclear Information System (INIS)

    In this study we report the temporally and spatially resolved electron densities and mean energies of a guided argon streamer in ambient argon and air obtained by Thomson laser scattering. The plasma is driven by a positive monopolar 3.5 kV pulse, with a pulse width of 500 ns and a frequency of 5 kHz which is synchronized with the high repetition rate laser system. This configuration enables us to use the spatial and temporal stability of the guided streamer to accumulate a multitude of laser/plasma shots by a triple grating spectrometer equipped with an ICCD camera and to determine the electron parameters. We found a strong initial ne-overshoot with a maximum of 7 × 1019 m−3 and a mean electron energy of 4.5 eV. This maximum is followed by a fast decay toward the streamer channel. Moreover, a 2D distribution of the electron density is obtained which exhibits a peculiar mushroom-like shape of the streamer head with a diameter significantly larger than that of the emission profile. A correlation of the width of the streamer head with the expected pre-ionization channel is found. (paper)

  5. Fluoride uptake into the developing enamel and dentine of sheep incisors following daily ingestion of fluoridated milk or water

    International Nuclear Information System (INIS)

    The caries preventive action of fluoride is common knowledge, although some of the mechanisms involved remain equivocal. At present, raised local levels of fluoride at, or in, the surface of tooth enamel is the most commonly accepted explanation of the anti-cariogenic action of fluoride. However, fluoride incorporated as fluorapatite into the tooth during its formation remains a possible alternative or complementary anti-cariogenic mechanism. If so, regular ingestion of fluoride during tooth formation is beneficial. Although use of fluoridated water is the preferred method in public health programmes, access to suitable potable water is required, and often this in not feasible. Fresh, preserved, or dried cow's milk products are widely used as nutritional and dietary items in most populations, particularly for young children. Milk is a practical, controllable means for regular delivery of fluoride. Processing of milk is commonly centralised and uses standardised conditions, allowing easy supplementation of fluoride for distribution to communities. The purpose of this study was to resolve the question of availability of fluoride ingested in milk compared with fluoride ingested in water by measuring fluoride deposition in the developing permanent incisors of young sheep. Incisors were analysed using a proton microprobe. (author). 18 refs., 1 tabs., 3 figs

  6. Water Fluoridation: A Critical Review of the Physiological Effects of Ingested Fluoride as a Public Health Intervention

    Directory of Open Access Journals (Sweden)

    Stephen Peckham

    2014-01-01

    Full Text Available Fluorine is the world’s 13th most abundant element and constitutes 0.08% of the Earth crust. It has the highest electronegativity of all elements. Fluoride is widely distributed in the environment, occurring in the air, soils, rocks, and water. Although fluoride is used industrially in a fluorine compound, the manufacture of ceramics, pesticides, aerosol propellants, refrigerants, glassware, and Teflon cookware, it is a generally unwanted byproduct of aluminium, fertilizer, and iron ore manufacture. The medicinal use of fluorides for the prevention of dental caries began in January 1945 when community water supplies in Grand Rapids, United States, were fluoridated to a level of 1 ppm as a dental caries prevention measure. However, water fluoridation remains a controversial public health measure. This paper reviews the human health effects of fluoride. The authors conclude that available evidence suggests that fluoride has a potential to cause major adverse human health problems, while having only a modest dental caries prevention effect. As part of efforts to reduce hazardous fluoride ingestion, the practice of artificial water fluoridation should be reconsidered globally, while industrial safety measures need to be tightened in order to reduce unethical discharge of fluoride compounds into the environment. Public health approaches for global dental caries reduction that do not involve systemic ingestion of fluoride are urgently needed.

  7. New argon-argon (40Ar/39Ar) radiometric age dates from selected subsurface basalt flows at the Idaho National Laboratory, Idaho

    Science.gov (United States)

    Hodges, Mary K.; Turrin, Brent D.; Champion, Duane E.; Swisher, Carl C., III

    2015-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected samples for 12 new argon-argon radiometric ages from eastern Snake River Plain olivine tholeiite basalt flows in the subsurface at the Idaho National Laboratory. The core samples were collected from flows that had previously published paleomagnetic data. Samples were sent to Rutgers University for argon-argon radiometric dating analyses.

  8. Effective use of fluorides for the prevention of dental caries in the 21st century

    DEFF Research Database (Denmark)

    Petersen, Poul Erik; Lennon, Michael A

    2004-01-01

    , due to changing living conditions and dietary habits, and inadequate exposure to fluorides. Research on the oral health effects of fluoride started around 100 years ago; the focus has been on the link between water and fluorides and dental caries and fluorosis, topical fluoride applications, fluoride...... toothpastes, and salt and milk fluoridation. Most recently, efforts have been made to summarize the extensive database through systematic reviews. Such reviews concluded that water fluoridation and use of fluoride toothpastes and mouthrinses significantly reduce the prevalence of dental caries. WHO recommends...... fluoridation schemes may be considered for prevention of dental caries....

  9. Evolution of Martian atmospheric argon: Implications for sources of volatiles

    Science.gov (United States)

    Hutchins, Kevin S.; Jakosky, Bruce M.

    We have examined processes affecting isotopes of argon (36Ar, 38Ar, 40Ar) in order to determine important atmospheric sources and sinks. Our simple model for argon evolution incorporates production of radiogenic argon in the mantle, outgassing of all argon species by extrusive and intrusive volcanism, and loss to space by knock-on sputtering above the exobase. Sputtering has been shown previously to be an important loss process for atmospheric species, especially isotopes of noble gases, which have few other mechanisms of escape. The integrated evolution of argon (36Ar, 38Ar, and 40Ar, respectively) is modeled in terms of these variables: (1) the planetary concentration of potassium, (2) the fraction of juvenile argon released catastrophically during the first 600 Myr., (3) potential variation in the time-history of sputtering loss from that suggested by Luhmann et al. [1992], and (4) the volume of total outgassing to the surface as compared to outgassing contributed by volcanic release. Our results indicate that Mars has lost between 85-95% of 36Ar and 70-88% of outgassed 40Ar. Due to this substantial loss, the planet must have outgassed the equivalent of between 10 and 100 times the total volume of gases released by extrusive and intrusive volcanics. This indicates that volcanic outgassing, alone, is insufficient to explain the present-day abundances of 36Ar and 40Ar in the Martian atmosphere. Similar calculations for 20Ne suggest outgassed volumes of between 100 and 1800 times in excess of that due to volcanism. This results in a distinct Ne/Ar elemental fractionation, with a preference for outgassing argon, of the order of 10 to 17. Although the results must be evaluated within the model uncertainties, the results are compelling in that they unequivocally show the existence of additional sources of atmospheric volatiles and helps define a means to identify them.

  10. Fluoride content of clay minerals and argillaceous earth materials

    Science.gov (United States)

    Thomas, J., Jr.; Glass, H.D.; White, W.A.; Trandel, R.M.

    1977-01-01

    A reliable method, utilizing a fluoride ion-selective electrode, is described for the determination of fluoride in clays and shales. Interference by aluminum and iron is minimal. The reproducibility of the method is about ??5% at different levels of fluoride concentration. Data are presented for various clay minerals and for the clays and shales. Fluoride values range from 44 ppm (0.0044%) for nontronite from Colfax, WA, to 51,800 ppm (5.18%) for hectorite from Hector, CA. In general, clays formed under hydrothermal conditions are relatively high in fluoride content, provided the hydrothermal waters are high in fluoride content. Besides hectorite, dickite from Ouray, CO, was found to contain more than 50 times as much fluoride (6700 ppm) as highly crystalline geode kaolinite (125 ppm). The clay stratum immediately overlying a fluorite mineralized zone in southern Illinois was found to have a higher fluoride content than the same stratum in a nonmineralized zone approximately 1 mile away. Nonmarine shales in contact with Australian coals were found to be lower in fluoride content than were marine shales in contact with Illinois coals. It is believed that, in certain instances, peak shifts on DTA curves of similar clay minerals are the result of significant differences in their fluoride content. ?? 1977.

  11. Community water fluoridation and caries prevention: a critical review.

    Science.gov (United States)

    Pizzo, Giuseppe; Piscopo, Maria R; Pizzo, Ignazio; Giuliana, Giovanna

    2007-09-01

    The aim of this paper was to critically review the current role of community water fluoridation in preventing dental caries. Original articles and reviews published in English language from January 2001 to June 2006 were selected through MEDLINE database. Other sources were taken from the references of the selected papers. For the past 50 years community water fluoridation has been considered the milestone of caries prevention and as one of the major public health measures of the 20th century. However, it is now accepted that the primary cariostatic action of fluoride occurs after tooth eruption. Moreover, the caries reduction directly attributable to water fluoridation have declined in the last decades as the use of topical fluoride had become more widespread, whereas enamel fluorosis has been reported as an emerging problem in fluoridated areas. Several studies conducted in fluoridated and nonfluoridated communities suggested that this method of delivering fluoride may be unnecessary for caries prevention, particularly in the industrialized countries where the caries level has became low. Although water fluoridation may still be a relevant public health measure in poor and disadvantaged populations, the use of topical fluoride offers an optimal opportunity to prevent caries among people living in both industrialized and developing countries. PMID:17333303

  12. Parabens do not increase fluoride uptake by dental enamel

    Directory of Open Access Journals (Sweden)

    Vanessa Silva Tramontino

    2010-04-01

    Full Text Available Objective: To evaluate whether methylparaben and propylparaben, which present a similar chemical structure, increase fluoride uptake by demineralized dental enamel when present in buffered solutions. Methods: The study comprised an in vitro experiment using blocks of bovine dental enamel with artificial carious lesions. Enamel blocks were exposed to the following treatment (n=12: fluoride solution (200 ppm fluoride - control; solution containing fluoride and 13 mM methylparaben; solution containing fluoride and 13 mM propylparaben in 35% propylene glycol; solution containing fluoride in 35% propylene glycol. All solutions were buffered (0.01 M cacodilate and the pH was adjusted to 6.27. The blocks were exposed to the treatment solutions in the proportion of 2 ml per mm2 of exposed enamel area and fluoride formed was estimated after removing an enamel layer by acid etching. Fluoride extracted was determined by ion specific electrode and the amount of enamel removed was estimated by phosphorus analysis. ANOVA followed by Tukey’s test were used for statistical analysis, with significance level at 5%. Results: The dental blocks of treatment groups containing both parabens and the control group presented similar fluoride concentration in enamel and no statistical difference was observed among them (p>0.05. The dental blocks of treatment group containing fluoride and propylene glycol showed the lowest value of fluoride present in enamel, which was significantly different from the control and fluoride and methylparaben groups (p<0.05. Conclusion: Methyl and propylparaben in a buffered solution do not enhance fluoride uptake by demineralized dental enamel.

  13. Urinary fluoride concentration as an estimator of welding fume exposure from basic electrodes.

    OpenAIRE

    Sjörgren, B; Hedström, L; Lindstedt, G.

    1984-01-01

    Urinary fluoride concentrations have been measured in electric arc welders using basic electrodes. The fluoride concentration and the total welding fume concentration in air showed a linear relation with postshift urinary fluoride concentration. The measured concentrations were below internationally recommended postshift urinary fluoride concentrations believed to cause fluorosis. Biological monitoring by postshift urinary fluoride measurements is evaluated for the prediction of total welding...

  14. Analysis of differentially expressed genes between fluoride-sensitive and fluoride-endurable individuals in midgut of silkworm, Bombyx mori.

    Science.gov (United States)

    Qian, Heying; Li, Gang; He, Qingling; Zhang, Huaguang; Xu, Anying

    2016-08-15

    Fluoride tolerance is an economically important trait of silkworm. Near-isogenic lines (NILs) of the dominant endurance to fluoride (Def) gene in Bombyx mori has been constructed before. Here, we analyzed the gene expression profiles of midgut of fluoride-sensitive and fluoride-endurable individuals of Def NILs by using high-throughput Illumina sequencing technology and bioinformatics tools, and identified differentially expressed genes between these individuals. A total of 3,612,399 and 3,567,631 clean tags for the libraries of fluoride-endurable and fluoride-sensitive individuals were obtained, which corresponded to 32,933 and 43,976 distinct clean tags, respectively. Analysis of differentially expressed genes indicates that 241 genes are differentially expressed between the two libraries. Among the 241 genes, 30 are up-regulated and 211 are down-regulated in fluoride-endurable individuals. Pathway enrichment analysis demonstrates that genes related to ribosomes, pancreatic secretion, steroid biosynthesis, glutathione metabolism, steroid biosynthesis, and glycerolipid metabolism are down-regulated in fluoride-endurable individuals. qRT-PCR was conducted to confirm the results of the DGE. The present study analyzed differential expression of related genes and tried to find out whether the crucial genes were related to fluoride detoxification which might elucidate fluoride effect and provide a new way in the fluorosis research. PMID:27106117

  15. Characterisation of GERDA Phase-I detectors in liquid argon

    International Nuclear Information System (INIS)

    GERDA will search for neutrinoless double beta decay in 76Ge by submerging bare enriched HPGe detectors in liquid argon. In GERDA Phase-I, reprocessed enriched-Ge detectors, which were previously operated by the Heidelberg-Moscow and IGEX collaborations, and reprocessed natural-Ge detectors from Genius-TF, will be redeployed. We have tested the operation and performance of bare HPGe detectors in liquid nitrogen and in liquid argon over more than three years with three non-enriched p-type prototype detectors. The detector handling and mounting procedures have been defined and the Phase-I detector technology, the low-mass assembly and the long-term stability in liquid argon have been tested successfully. The Phase-I detectors were reprocessed by Canberra Semiconductor NV, Olen, according to their standard technology but without the evaporation of a passivation layer. After their reprocessing, the detectors have been mounted in their low-mass holders and their characterisation in liquid argon performed. The leakage current, the counting characteristics and the efficiency of the detectors have been measured. The testing of the detectors was carried out in the liquid argon test stand of the GERDA underground Detector Laboratory (GDL) at LNGS. The detectors are now stored underground under vacuum until their operation in GERDA.

  16. The Effect of Calcium Pre-Rinse on Salivary Fluoride After 900 ppm Fluoride Mouthwash: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Nahid Ramazani

    2013-01-01

    Full Text Available Objective: Calcium fluoride deposit during fluoride application. Uptake and retention of fluoride by saliva depends generally on the concentration of calcium. In this study, the ef-fect of calcium pre-rinse on salivary fluoride concentration after a 900 ppm fluoride mouthwash was investigated.Materials and Methods: This cross-over double-blind randomized clinical trial was con-ducted in a girls' dormitory in Zahedan University of Medical Sciences, southeast Iran. In this study, 42 female dental students were chosen using simple randomization. During the first phase, 21 subjects (group A used fluoride rinse (F regimen and the remaining (group B used calcium pre-rinse followed immediately by fluoride rinse (Ca + F regi-men. In the second phase, participants rinsed using the mouthwashes not previously used. Prior to each phase prophylaxis was performed and no fluoridated product was used dur-ing a two-week interval between the phases. Salivary samples were taken immediately be-fore (baseline, 1 and 12 hours after rinsing. The salivary fluoride concentration was de-termined using fluoride sensitive electrode. Repeated measures ANOVA was used for sta-tistical analysis and the significance level was set at P<0.05.Results: There was significant difference between fluoride concentrations at different time points (P< 0.001. Significant differences were observed when the different time points of two regimens were examined. In contrast to this, the baseline before using F regimen and the baseline before using Ca + F regimen did not show any significance (P= 0.070.Conclusion: Pre-rinsing with calcium before fluoride is recommended because of signifi-cant increases in salivary fluoride concentration.

  17. Revisiting the thermochemistry of chlorine fluorides

    CERN Document Server

    Sánchez, H R

    2016-01-01

    In this work, accurate calculations of standard enthalpies of formation of chlorine fluorides (ClF$_n$, n=1--7; Cl$_2$F and Cl$_3$F$_2$) were performed through the isodesmic reactions scheme. It is argued that, for many chlorine fluorides, the gold standard method of quantum chemistry (CCSD(T)) is not capable to predict enthalpy values nearing chemical accuracy if atomization scheme is used. This is underpinned by a thorough analysis of total atomization energy results and the inspection of multireference features of these compounds. Other thermodynamic quantities were also calculated at different temperatures. In order to complement the energetic description, elimination curves were studied through density functional theory as a computationally affordable alternative to highly correlated wave function-based methods.

  18. Plutonium oxide obtainment from a plutonium fluoride

    International Nuclear Information System (INIS)

    The need to recover the Pu existing in the Alpha Facility for the experimental fabrication of mixed oxides fuel elements (U,Pu)O2, its recovery has been set up from the F4Pu available at the laboratory. To fulfill the strict specifications on fluorides in nuclear fuels, it was necessary to precisely adjust the purification phase. This paper describes the chemical process for the PuO2 obtainment from F4Pu. F4Pu was dissolved in nitric acid, adding aluminium nitrate. The concentration in the medium decreases due to the complexes formation with fluorides and this allows the full dissolution of the salt. Pu separation was carried out by the treatment with RESINE DOWEX in columns. After purification with successive washes in NO3H7M, Pu elution retained in the column was performed. Finally, it precipitated as Pu IV oxalate and PuO2 was obtained by calcination at 700 deg C. (Author)

  19. Fluoridation and tooth wear in Irish adults.

    LENUS (Irish Health Repository)

    Burke, F M

    2010-10-01

    The aim of this study was to determine the prevalence of tooth wear in adults in Ireland and its relationship with water fluoridation. The National Survey of Adult Oral Health was conducted in 2000\\/2001. Tooth wear was determined using a partial mouth examination assessing the upper and lower anterior teeth. A total of 2456 subjects were examined. In this survey, increasing levels and severity of tooth wear were associated with ageing. Men were more affected by tooth wear and were more likely to be affected by severe tooth wear than women. It was found that age, and gender were significant predictors of tooth wear (P < 0.01). Overall, there was no significant relationship between fluoridation and tooth wear in this study.

  20. The hydride fluoride crystal structure database, HFD

    Energy Technology Data Exchange (ETDEWEB)

    Gingl, F.; Gelato, L.; Yvon, K. [Geneva Univ. (Switzerland). Lab. Crystallographie aux Rayons X

    1997-05-20

    HFD is a new data base containing crystal structure information on more than one thousand metal hydrides and fluorides. It includes space group, cell parameters, standardized atom positions, site occupancies and references. The compilation is critical as only refined crystal structures are considered and the data are checked for internal consistency. It is comprehensive as structural information is extracted from all major scientific journals, and it is continuously updated. HFD can be searched according to various criteria such as symmetry, chemical elements, composition etc. The primary motivation for creating HFD was to predict new metal hydrides and to study their structural analogies with metal fluorides. However, HFD can also be used for other applications such as the simulation of diffraction patterns and the drawing of crystal structures. (orig.) 13 refs.

  1. Fluoride solid electrolytes containing rare earth elements

    Institute of Scientific and Technical Information of China (English)

    Viera Trnovcová; Pavel P. Fedorov; Ivan Furár

    2008-01-01

    Relations between the structure, ionic conductivity and dielectric properties of fluoride systems of different structures containing rare earth elements were presented. Superionic conductivities, by fluoride ions, of fluorite-structured (MF2-REF3, M=Ba, Pb, RE=La-Lu, Sc, Y), orthorhombic (REF3, RE=Tb-Er,Y), tysonite-structured (REF3-MF2, RE=La-Nd, M=Sr), monoclinic (BaRE2F8, RE=Ho-Yb, Y) fluoride single crystals and eutectic composites (LiF-REF3, RE=La-Gd,Y) were compared. Anisotropy of electrical properties of crystals with a lower symmetry was explained by modeling optimum ionic paths. For explanation of concentration dependences of fast ionic conductivity, models of aggregation of defects into clusters were proposed. In fluorite-structured crystals, the highest ionic conductivity was found for PbF2: 7 mol% ScF3 (at 500 K, σ500=0.13 S/cm). In tysonite-structured crystals, the highest ionic conductivity was found for LaF3: 3 mol% SrF2 (σ500=2.4×10-2 S/cm). Different types of coordination polyhedrons and their different linking in orthorhombic and tysonite structure explained large differences between conductivities in both structures. Eutectic systems, prepared as directionally solidified composites, enabled to study some orthorhombic fluoride phases (GdF3, SmF3), which cannot be prepared as single crystals. An influence of the orthorhombic-tysonite phase transition on the ionic conductivity was shown.

  2. Health protection: Fluoridation and dental health.

    OpenAIRE

    1983-01-01

    Tooth decay, which affects 95 percent of Americans, is our most common health problem, costing an estimated +2 billion yearly for treatment. By the time children reach 17 years of age, 94 percent have experienced caries and 36 percent have lost one or more permanent teeth due to caries. Dental disease prevention embodies the spectrum of many activities from the fluoridation of community and school water supplies to the dental health education of the child and adult. At this stage of our knowl...

  3. Delivery Challenges for Fluoride, Chlorhexidine and Xylitol

    OpenAIRE

    Featherstone, John DB

    2006-01-01

    The progression or reversal of dental caries is determined by the balance between pathological and protective factors. It is well established that a) fluoride inhibits demineralization and enhances remineralization, b) chlorhexidine reduces the cariogenic bacterial challenge, and c) xylitol is non-cariogenic and has antibacterial properties. The challenge that we face is how best to deliver these anti-caries entities at true therapeutic levels, over time, to favorably tip the caries balance. ...

  4. Effect of fluoride toothpastes on enamel demineralization

    Directory of Open Access Journals (Sweden)

    Gintner Zeno

    2006-06-01

    Full Text Available Abstract Background It was the aim of this study to investigate the effect of four different toothpastes with differing fluoride compounds on enamel remineralization. Methods A 3 × 3 mm window on the enamel surface of 90 human premolars was demineralized in a hydroxyethylcellulose solution at pH 4.8. The teeth were divided into 6 groups and the lower half of the window was covered with varnish serving as control. The teeth were immersed in a toothpaste slurry containing: placebo tooth paste (group 1; remineralization solution (group 2; Elmex Anticaries (group 3; Elmex Sensitive (group 4; Blend-a-med Complete (group 5 and Colgate GRF (group 6. Ten teeth of each group were used for the determination of the F- content in the superficial enamel layer and acid solubility of enamel expressed in soluble phosphorus. Of 6 teeth of each group serial sections were cut and investigated with polarization light microscopy (PLM and quantitative energy dispersive X-ray analysis (EDX. Results The PLM results showed an increased remineralization of the lesion body in the Elmex Anticaries, Elmex Sensitive and Colgate GRF group but not in the Blend-a-med group. A statistically significant higher Ca content was found in the Elmex Anticaries group. The fluoride content in the superficial enamel layer was significantly increased in both Elmex groups and the Blend-a-med group. Phosphorus solubility was significantly decreased in both Elmex groups and the Blend-a-med group. Conclusion It can be concluded that amine fluoride compounds in toothpastes result in a clearly marked remineralization of caries like enamel lesions followed by sodium fluoride and sodium monofluorophosphate formulations.

  5. Necessity to review the Brazilian regulation about fluoride toothpastes

    Science.gov (United States)

    Cury, Jaime Aparecido; Caldarelli, Pablo Guilherme; Tenuta, Livia Maria Andaló

    2015-01-01

    The aim of this study was to evaluate the adequacy of the Brazilian legislation about fluoride toothpaste. A search was conducted in LILACS, Medline and SciELO databases about the fluoride concentration found in Brazilians toothpastes, using descriptors on health. Publications since 1981 have shown that some Brazilian toothpastes are not able to maintain, during their expiration time, a minimum of 1,000 ppm F of soluble fluoride in the formulation. However, the Brazilian regulation (ANVISA, Resolution 79, August 28, 2000) only sets the maximum total fluoride (0.15%; 1,500 ppm F) that a toothpaste may contain but not the minimum concentration of soluble fluoride that it should contain to have anticaries potential, which according to systematic reviews should be 1,000 ppm F. Therefore, the Brazilian regulation on fluoride toothpastes needs to be revised to assure the efficacy of those products for caries control. PMID:26487295

  6. [Problems of fluoride dosing to infants for dental fluorosis prevention].

    Science.gov (United States)

    Davydov, B N; Borinskaia, E Iu; Kushnir, S M; Borinskiĭ, Iu N; Beliaev, V V

    2011-01-01

    Fluoride content in drinking water, breast milk, cow milk, additional food for newborns prepared with water containing different amount of fluoride was determined. Fluoride excretion in urine since the first days of birth and up to 4 months of postnatal development was investigated in breast and artificially fed infants. When a neonate was fed with breast milk, fluoride was received in the amount no more than 20 mkg/day. The additional food contained fluoride which water mainly had. Water with high level of fluorine increased its content in the additional food up to the values not comparable to those in breast milk that presented danger of dental fluorosis development. Data on fluorine content in drinking water were absolutely necessary to calculate daily fluorides consumption by infants and to prevent dental fluorosis. PMID:21378727

  7. The effective use of fluorides in public health

    DEFF Research Database (Denmark)

    Jones, Sheila; Burt, Brian A; Petersen, Poul Erik;

    2005-01-01

    , systematic reviews summarizing these extensive databases have indicated that water fluoridation and fluoride toothpastes both substantially reduce the prevalence and incidence of dental caries. We present four case studies that illustrate the use of fluoride in modern public health practice, focusing on......Dental caries remain a public health problem for many developing countries and for underprivileged populations in developed countries. This paper outlines the historical development of public health approaches to the use of fluoride and comments on their effectiveness. Early research and...... development was concerned with waterborne fluorides, both naturally occurring and added, and their effects on the prevalence and incidence of dental caries and dental fluorosis. In the latter half of the 20th century, the focus of research was on fluoride toothpastes and mouth rinses. More recently...

  8. High Fluoride Dentifrices for Elderly and Vulnerable Adults

    DEFF Research Database (Denmark)

    Ekstrand, Kim Rud

    The primary aim of this work is to present the available evidence that toothpastes containing >1,500 ppm fluoride (2,500-2,800 and 5,000 ppm F) provide an additional caries preventive effect on root caries lesions in elderly patients compared to traditional dentifrices (1,000-1,450 ppm F). The...... secondary aim of this paper is to discuss why high fluoride dentifrices in general should perform better than traditional F-containing toothpaste. When examining the few studies that have considered the preventive benefits of high fluoride products on root caries the relative risk appears to be around 0.......5, and the risk can thus be halved by exchanging traditional F-containing toothpaste for toothpaste containing 5,000 ppm F. There is reasonable evidence that high fluoride dentifrices significantly increase the fluoride concentration in saliva during the day and the fluoride concentration in plaque...

  9. Necessity to review the Brazilian regulation about fluoride toothpastes

    Directory of Open Access Journals (Sweden)

    Jaime Aparecido Cury

    2015-01-01

    Full Text Available The aim of this study was to evaluate the adequacy of the Brazilian legislation about fluoride toothpaste. A search was conducted in LILACS, Medline and SciELO databases about the fluoride concentration found in Brazilians toothpastes, using descriptors on health. Publications since 1981 have shown that some Brazilian toothpastes are not able to maintain, during their expiration time, a minimum of 1,000 ppm F of soluble fluoride in the formulation. However, the Brazilian regulation (ANVISA, Resolution 79, August 28, 2000 only sets the maximum total fluoride (0.15%; 1,500 ppm F that a toothpaste may contain but not the minimum concentration of soluble fluoride that it should contain to have anticaries potential, which according to systematic reviews should be 1,000 ppm F. Therefore, the Brazilian regulation on fluoride toothpastes needs to be revised to assure the efficacy of those products for caries control.

  10. Adsorption of Fluoride Ion by Inorganic Cerium Based Adsorbent

    Institute of Scientific and Technical Information of China (English)

    Jiao Zhongzhi(焦中志); Chen Zhonglin; Yang Min; Zhang Yu; Li Guibai

    2004-01-01

    Excess of fluoride in drinking water is harmful to human health, the concentration of F- ions must be maintained in the range of 0.5 to 1.5 mg/L. An inorganic cerium based adsorbent (CTA) is developed on the basis of research of adsorption of fluoride on cerium oxide hydrate. Some adsorption of fluoride by CTA adsorbent experiments were carried out, and results showed that CTA adsorbent has a quick adsorption speed and a large adsorption capacity. Adsorption follows Freundlich isotherm, and low pH value helps fluoride removal. Some physical-chemical characteristics of CTA adsorbent were experimented, fluoride removal mechanism was explored, and results showed that hydroxyl group of CTA adsorbent played an important role in the fluoride removal.

  11. Distribution of fluoride in ground water of West Virginia

    Science.gov (United States)

    Mathes, M.V.; Waldron, M.C.

    1993-01-01

    This report describes the results of a study by the U.S. Geological Survey, in cooperation with the West Virginia Geological and Economic Survey, to evaluate the distribution of fluoride in ground water of West Virginia. Fluoride is a natural chemical constituent in domestic and public water supplies in West Virginia. Fluoride concentrations of about 1.0 milligram per liter in drinking water are beneficial to dental health. Concentrations greater than 2.0 milligrams per liter, however, could harm teeth and bones. Fluoride concentra- tions in ground water of West Virginia range from less than 0.1 to 12 milligrams per liter. Fluoride concentrations that exceed 2.0 milligrams per liter are found in wells drilled to all depths, wells drilled in all topographic settings, and wells drilled into most geologic units. Most fluoride concentrations that exceed 2.0 milligrams per liter are located at sites clustered in the northwestern part of the State.

  12. Bone scintigraphy in fluoride treated osteoporosis

    International Nuclear Information System (INIS)

    Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. They also demonstrate the utility of serial quantitative bone scintigraphy in assessing osteoporotic patients with vertebral compression fractures

  13. The electric field gradient in fluorides

    International Nuclear Information System (INIS)

    The electric quadrupole hyperfine interaction was investigated for various fluorides by the time-differential observation of the perturbed γ angular correlation and the Kern-Hanle effect of the 197 keV radiation of the 5/2+ level in 19F. This level was excited by inelastic proton scattering. The dependence of the quadrupole coupling constant from the chemical bond of the atom to its ligands was measured in fluorides of two-valid transition elements and in pureley covalent molecules, as (CF2)sub(n) or SF6. The influence of radiation-induced defects in nonmetals was investigated for cubic fluorides between 80 K and 1050 K. For CaF2 two different field gradients are obtained with coupling constants between 27 MHz and 3 MHz. By measurements of the angular distribution for CaF2/PrF3 mixed crystals which contain a variable concentration of F- interstitials was shown that the appearance of the 3 MHz frequency is correlated with the concentration of F- interstitials in CaF2. (BHO)

  14. Biological effects data: Fluoride and sulfur dioxide

    Energy Technology Data Exchange (ETDEWEB)

    McMechan, K.J. (ed.); Holton, R.L.; Ulbricht, R.J.; Morgan , J.B.

    1975-04-01

    The Alumax Pacific Aluminum Corporation has proposed construction of an aluminum reduction facility near Youngs Bay at Warrenton, Oregon. This report comprises one part of the final report to Alumax on a research project entitled, Physical, Chemical and Biological Studies of Youngs Bay.'' It presents data pertaining to the potential biological effects of fluoride and sulfur dioxide, two potentially hazardous plant-stack emissions, on selected aquatic species of the area. Companion volumes provide a description of the physical characteristics the geochemistry, and the aquatic animals present in Youngs Bay and adjacent ecosystems. An introductory volume provides general information and maps of the area, and summarizes the conclusions of all four studies. The data from the two phases of the experimental program are included in this report: lethal studies on the effects of selected levels of fluoride and sulfur dioxide on the survival rate of eleven Youngs Bay faunal species from four phyla, and sublethal studies on the effects of fluoride and sulfur dioxide on the rate of primary production of phytoplankton. 44 refs., 18 figs., 38 tabs.

  15. Studies on fluoride complexing of hexavalent actinides using a fluoride ion selective electrode

    International Nuclear Information System (INIS)

    Complex formation between actinide(VI) and fluoride ions in aqueous solutions was investigated using a fluoride ion selective electrode (F-ISE). As fairly high acidity used to suppress hydrolysis of the actinide(VI) ions, significant liquid junction potentials (Esub(j)) existed in the system. An iterative procedure was developed for computing free hydrogen ion concentration [Hsup(+)] as it colud not be measured directly, using data obtained with F-ISE. Esub(j) values were estimated from known [Hsup(+)] and the stability constants of fluoride complexes of actinide(VI) ions were calculated following King and Gallagher's method using a computer program. The stability constants were found to follow the order U(VI)>Np(VI)>Pu(VI). (author)

  16. A health risk assessment for fluoride in Central Europe

    OpenAIRE

    Fordyce, Fiona; Vrana, K.; Zhovinsky, E.; Povoroznuk, V.; Toth, G.; Hope, B.C.; Iljinsky, U.; Baker, J.

    2007-01-01

    Like many elements, fluorine (which generally occurs in nature as fluoride) is beneficial to human health in trace amounts, but can be toxic in excess. The links between low intakes of fluoride and dental protection are well known; however, fluoride is a powerful calcium-seeking element and can interfere with the calcified structure of bones and teeth in the human body at higher concentrations causing dental or skeletal fluorosis. One of the main exposure routes is via drinking water and the ...

  17. Use of professionally administered topical fluorides in Asia

    OpenAIRE

    Tenuta, LMA; Fox, CH; Lo, ECM

    2012-01-01

    Professionally applied topical fluoride varnish, gel, and solution have been shown to be effective in preventing and in arresting dental caries. Their use in different countries in Asia varies greatly and may not correlate with the dental caries situation of the populations in the countries. In the higher-income countries, use of fluoride varnish and gel is common among dental professionals. In contrast, the use of professionally administered topical fluorides is not common in the lower-incom...

  18. The status of community water fluoridation in the United States.

    OpenAIRE

    Easley, M W

    1990-01-01

    Community water fluoridation has served the American public extremely well as the cornerstone of dental caries prevention activities for 45 years. The dental and general health benefits associated with the ingestion of water-borne fluorides have been well known by researchers for an even longer period. Continued research has repeatedly confirmed the safety, effectiveness, and efficiency of community water fluoridation in preventing dental caries for Americans regardless of age, race, ethnicit...

  19. Argon-40: Excess in submarine pillow basalts from Kilauea Volcano, Hawaii

    Science.gov (United States)

    Brent, Dalrymple G.; Moore, J.G.

    1968-01-01

    Submarine pillow basalts from Kilauea Volcano contain excess radiogenic argon-40 and give anomalously high potassium-argon ages. Glassy rims of pillows show a systematic increase in radiogenic argon-40 with depth, and a pillow from a depth of 2590 meters shows a decrease in radiogenic argon-40 inward from the pillow rim. The data indicate that the amount of excess radiogenic argon-40 is a direct function of both hydrostatic pressure and rate of cooling, and that many submarine basalts are not suitable for potassium-argon dating.

  20. Metastable argon beam source using a surface wave sustained plasma

    International Nuclear Information System (INIS)

    A new source of metastable argon atoms in the thermal energy range is reported. The source is based on expanding a plasma sustained by electromagnetic surface waves in a quartz tube through a converging nozzle and extracting a beam from the supersonic free-expansion jet. The beam was characterized by time-of-flight measurements which yielded the absolute intensity and velocity distribution of the argon metastables. The source produced a maximum intensity of 6.2x1014 metastables per second per steradian, the highest time-averaged intensity of thermal argon metastables of any source reported to date. A simple picture of an expanding plasma in a recombination regime is used to explain the dependence of the metastable intensity on absorbed power

  1. On the electric breakdown in liquid argon at centimeter scale

    Science.gov (United States)

    Auger, M.; Blatter, A.; Ereditato, A.; Goeldi, D.; Janos, S.; Kreslo, I.; Luethi, M.; von Rohr, C. Rudolf; Strauss, T.; Weber, M. S.

    2016-03-01

    We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  2. Pressure regulation in the dry-boxes. Argon purification

    International Nuclear Information System (INIS)

    Each dry-box is equipped with an autonomous installation for circulation and purification of argon and for pressure regulation. This installation consists essentially of a ballast tank, a compressor and two valves electromagnetically controlled by a contact manometer. The compressor and the valves are enclosed in the tank to form a system as compact as possible. The argon is purified by passing it over a furnace filled with titanium-zirconium turnings brought to about 800 deg. C, branching off the main system. With this set-up as well as the automatic maintenance of a constant depression in the box, a quality of argon is obtained whose oxygen contact is undetectable by the manganous hydroxide method. (author)

  3. Bacteria Inactivation Using DBD Plasma Jet in Atmospheric Pressure Argon

    International Nuclear Information System (INIS)

    A coaxial dielectric barrier discharge plasma jet was designed, which can be operated in atmospheric pressure argon under an intermediate frequency sinusoidal resonant power supply, and an atmospheric pressure glow-like discharge was achieved. Two kinds of typical bacteria, i.e., the Staphylococcus aureus (S. aureus) and Escherichia coil (E. coil), were employed to study the bacterial inactivation mechanism by means of the non-thermal plasma. The killing log value (KLV) of S. aureus reached up to 5.38 with a treatment time of 90 s and that of E. coil up to 5.36 with 60 s, respectively. According to the argon emission spectra of the plasma jet and the scanning electron microscope (SEM) images of the two bacteria before and after the plasma treatment, it is concluded that the reactive species in the argon plasma played a major role in the bacterial inactivation, while the heat, electric field and UV photons had little effect. (plasma technology)

  4. Energy resolution studies of liquid argon ionization detectors

    International Nuclear Information System (INIS)

    A gridded ionization chamber was used to study the energy resolution in liquid argon with electrons from a 207Bi radioactive source. Argon was purified in the gas phase with a simple and reliable system, capable of reducing the impurity level below 1 ppb O2 equivalent, as inferred by a pulse shape analysis of the ionization signals. The electron spectrum was measured at different drift fields, up to 10.9 KV/cm. At this maximum field, a total energy resolution of 32 keV (fwhm), corresponding to a noise-subtracted energy resolution of 26 keV (fwhm), was obtained for the 976 keV conversion electron line. This value is the best reported so far in liquid argon but is still a factor of seven worse than the theoretical limit set by the Fano factor. The reasons for this discrepancy are discussed. (orig.)

  5. Attenuation measurements of vacuum ultraviolet light in liquid argon revisited

    CERN Document Server

    Neumeier, A; Himpsl, A; Hofmann, M; Oberauer, L; Potzel, W; Schönert, S; Ulrich, A

    2015-01-01

    The attenuation of vacuum ultraviolet light in liquid argon in the context of its application in large liquid noble gas detectors has been studied. Compared to a previous publication several technical issues concerning transmission measurements in general are addressed and several systematic effects were quantitatively measured. Wavelength-resolved transmission measurements have been performed from the vacuum ultraviolet to the near-infrared region. On the current level of sensitivity with a length of the optical path of 11.6 cm, no xenon-related absorption effects could be observed, and pure liquid argon is fully transparent down to the short wavelength cut-off of the experimental setup at 118 nm. A lower limit for the attenuation length of pure liquid argon for its own scintillation light has been estimated to be 1.10 m based on a very conservative approach.

  6. On the Electric Breakdown in Liquid Argon at Centimeter Scale

    CERN Document Server

    Auger, M; Ereditato, A; Goeldi, D; Janos, S; Kreslo, I; Luethi, M; von Rohr, C Rudolf; Strauss, T; Weber, M S

    2015-01-01

    We present a study on the dependence of electric breakdown discharge parameters on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  7. Liquid Argon Calorimetry with LHC-Performance Specifications

    CERN Multimedia

    2002-01-01

    % RD-3 Liquid Argon Calorimetry with LHC-Performance Specifications \\\\ \\\\Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. Among the techniques used so far, or under development, the liquid argon sampling calorimetry offers high radiation resistence, good energy resolution (electromagnetic and hadronic), excellent calibration stability and response uniformity. Its rate capabilities, however, do not yet match the requirements for LHC. \\\\ \\\\The aim of this proposal is to improve the technique in such a way that high granularity, good hermiticity and adequate rate capabilities are obtained, without compromising the above mentioned properties. To reach this goal, we propose to use a novel structure, the $^{\\prime\\prime}$accordion$^{\\prime\\prime}$, coupled to fast preamplifiers working at liquid argon temperature. Converter and readout electrodes are no longer planar and perpendicular to particles, as usual, but instead they are wiggled around a plane containing particles. ...

  8. Sodium fluoride influences the expression of keratins in cultured keratinocytes

    OpenAIRE

    Prado, Euridice; Wurtz, Tilmann; Ferbus, Didier; Shabana, El-Hassan; FOREST, Nadine; Berdal, Ariane

    2010-01-01

    Epithelia in lung, skin, and kidney are often exposed to fluoride, and tissue damage in lung and kidney due to fluoride is well documented. Nevertheless, the biological effects of fluoride on epithelia are poorly investigated. In the present study, we report effects of sodium fluoride (NaF) on the differentiation of a human epithelial cell line, HaCaT. These cells may serve as a keratinocyte model, because they express a wide spectrum of keratins (Ks), and they associate into stratified tissu...

  9. Effects of oral doses of fluoride on nestling European starlings

    Science.gov (United States)

    Fleming, W.J.; Grue, C.E.; Schuler, C.A.; Bunck, C.M.

    1987-01-01

    Nestling European starlings (Sturnus vulgaris), raised and fed by free-living adults, were given daily oral doses of either distilled water, 193 mg sodium as Na2CO3 per kg of body weight (sodium control group), or 6, 10, 13, 17,23, 30, 40, 80, 160 mg of the fluoride ion as NaF in distilled water per kg of body weight (mg/kg). Dosing began when nestlings were 24-48 hr old and continued for 16 days. The 24-hr LD50 of fluoride for day-old starlings was 50 mg/kg. The 16-day LD50 was 17 mg/kg. The sodium control group did not differ from the water control group with respect to any of the measured variables. Growth rates were significantly reduced in the 13 and 17 mg of fluoride/kg groups; weights of birds given higher dose levels were omitted from growth comparisons because of high, fluoride-induced mortality. Although pre-fledging weights for the 10, 13, and 17 mg of fluoride/kg groups averaged 3.6 to 8.6% less than controls at 17 days, this difference was not significant. Feather and bone growth of the fluoride and control groups were not different, except for keel length measured at 17 days of age which averaged less in the fluoride groups. Liver and spleen weights were not affected by fluoride treatments. No histological damage related to fluoride treatments was found in liver, spleen, or kidney. The logarithm of bone fluoride and magnesium concentration increased with the logarithm of increasing fluoride treatment levels and were significantly correlated with each other. Fluoride treatments had no effect on percent calcium or phosphorus in bone or plasma alkaline phosphatase activity. Oral doses of fluoride appear to be more toxic than equivalent dietary levels. Most birds probably acquire fluoride through their diet. Therefore, the results of the study may overestimate the potential effects of fluorides on songbirds living in fluoride-contaminated environments.

  10. Oxidative stress in cases of chronic fluoride intoxication

    OpenAIRE

    Ailani, Vinita; R. C. Gupta; Gupta, Sunil Kumar; Gupta, Kapil

    2009-01-01

    This study was conducted to find out the level of oxidative stress and effect of supplementation of vitamin C, D and Calcium on levels of SOD, serum and urinary fluoride in children residing in endemic fluorosis area. For this the fluoride belt of Jaipur district was selected. The parameters selected were Super oxide dismutase, serum fluoride and urinary fluoride. The study was conducted on one hundred children, selected from four areas (25 from each area) consuming water containing 1.2, 2.4,...

  11. Laser propagation and energy absorption by an argon spark

    OpenAIRE

    Bindhu, C V; Harilal, S S; Tillack, M. S.; Najmabadi, F; Gaeris, A C

    2003-01-01

    The laser propagation and energy absorption of an argon spark induced by a laser at different pressures is investigated. 8 ns pulses from a frequency-doubled Q-switched Nd:YAG laser are used to create the spark. The pressure of the argon is varied from 1 atm to 10 Torr. Significant energy absorption by the plasma is observed at high pressures (>100 Torr) while there is negligible absorption when the pressure is lower than 50 Torr. The plasma kernel showed distinct behavior with respect to las...

  12. Modelling of a supersonic ICP argon-hydrogen expansion

    International Nuclear Information System (INIS)

    An expanding argon-hydrogen plasma is investigated by means of simulations. The model is a hydrodynamical model specific for plasma expansions, taking into account the conservation laws of mass, momentum and energy. The code includes the Rankine-Hugoniot relations to calculate shock jump conditions. Results are shown for the expansion from an inductively coupled plasma (ICP) with a separated Laval nozzle. The expansion discussed here is a 'weakly' under-expanding argon-hydrogen plasma. The results from the ICP expansion are verified with probe measurements

  13. Oxygen removal from tantalum and niobium in an argon atmosphere

    International Nuclear Information System (INIS)

    The rate of oxygen removal from tantalum and niobium has been determined as a function of argon pressure (0-760 Torr) at temperatures from 1900 to 24000C. The reduction of the reaction rate v depends only on the argon pressure and can be given by a factor α = v/v0. The following formulae are obtained for α: Ta: α = (1 + 0.15psub(Ar)sup(0.9))-1, Nb: α = (1 + 0.5psub(Ar)sup(0.9))-1.

  14. Photoionization in liquid argon doped with trimethylamine or triethylamine

    International Nuclear Information System (INIS)

    Ionization yields for alpha particles and 1 MeV electrons in liquid argon doped with trimethylamine and with triethylamine have been measured. In both liquids, a collected charge larger than Anderson's results is observed for alpha particles although that for electrons is similar to Anderson's value. By using a new equation for the collected charge, the photoionization quantum efficiencies for scintillation light in liquid argon are estimated to be 0.35+-0.05 for trimethylamine and greater than 0.23+-0.03 for triethylamine. (orig.)

  15. Superconductivity of compressed solid argon from first principles

    Science.gov (United States)

    Ishikawa, Takahiro; Asano, Masamichi; Suzuki, Naoshi; Shimizu, Katsuya

    2015-02-01

    We present first-principles calculations on the superconductivity of solid argon under high pressure. Solid argon is found to take the double hexagonal close-packed structure in pressure range from 420 to 690 GPa, where an insulator-to-metal transition occurs at around 590 GPa. The crystal structure transforms into the hexagonal close-packed structure at 690 GPa and into the face-centered cubic structure at 2300 GPa. The superconducting critical temperature is gradually increased with the successive phase transitions and reaches the maximum value of 12 K at 2600 GPa due to the enhancement of the Fermi surface nesting.

  16. Attosecond-correlated dynamics of two electrons in argon

    Indian Academy of Sciences (India)

    V Sharma; N Camus; B Fischer; M Kremer; A Rudenko; B Bergues; M Kuebel; N G Johnson; M F Kling; T Pfeifer; J Ullrich; R Moshammer

    2014-01-01

    In this work we explored strong field-induced decay of doubly excited transient Coulomb complex Ar** → Ar2++2. We measured the correlated two-electron emission as a function of carrier envelop phase (CEP) of 6 fs pulses in the non-sequential double ionization (NSDI) of argon. Classical model calculations suggest that the intermediate doubly excited Coulomb complex loses memory of its formation dynamics. We estimated the ionization time difference between the two electrons from NSDI of argon and it is 200 ± 100 as (N Camus et al, Phys. Rev. Lett. 108, 073003 (2012)).

  17. The ATLAS liquid argon electromagnetic calorimeter construction status

    CERN Document Server

    Jérémie, A

    2004-01-01

    The construction and assembly of the ATLAS liquid argon electromagnetic calorimeter was described. The calorimeter was built with accordion geometry composed of lead absorbers, liquid argon as ionizing medium and highly granular readout electrodes. The calorimeter was composed of the Barrel and the End-cap, both preceded by presampler sectors to ensure complete recovery of the energy resolution. The detection of cabling errors and testing of the whole calibration chain was done by sending a pulse through the calibration circuit with single readout. (Edited abstract) 3 Refs.

  18. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.; Hansen, Jens Leonhart; Sørensen, H.

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore unequivo......The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...

  19. Measurement of Longitudinal Electron Diffusion in Liquid Argon

    CERN Document Server

    Li, Yichen; Thorn, Craig; Qian, Xin; Diwan, Milind; Joshi, Jyoti; Kettell, Steve; Morse, William; Rao, Triveni; Stewart, Jim; Tang, Wei; Viren, Brett

    2015-01-01

    We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data analysis are described. Our results, which are consistent with previous measurements in the region between 100 to 350 V/cm [1] , are systematically higher than the prediction of Atrazhev-Timoshkin[2], and represent the world's best measurement in the region between 350 to 2000 V/cm. The quantum efficiency of the gold photocathode, the drift velocity and longitudinal diffusion coefficients in gas argon are also presented.

  20. Total Fluoride Intake and Urinary Excretion in German Children Aged 3–6 Years

    OpenAIRE

    Haftenberger, Marjolein; Viergutz, Gabriele; Neumeister, Volker; Hetzer, Gisela

    2014-01-01

    There have only been few investigations comparing total fluoride intake and the fluoride proportion excreted in urine in pre–school children. In addition, the results of available studies are conflicting. Total fluoride intake was assessed in 11 healthy children aged 3–6 years on 2 consecutive days and urinary fluoride excretion was determined. The duplicate–diet approach was used for the assessment of fluoride intake from solid and liquid foods. Fluoride intake from toothbrushing was calcula...

  1. Effect of exercise on fluoride metabolism in adult humans: a pilot study

    OpenAIRE

    Fatemeh V. Zohoori; Alison Innerd; Azevedo, Liane B; Whitford, Gary M.; Anne Maguire

    2015-01-01

    An understanding of all aspects of fluoride metabolism is critical to identify its biological effects and avoid fluoride toxicity in humans. Fluoride metabolism and subsequently its body retention may be affected by physiological responses to acute exercise. This pilot study investigated the effect of exercise on plasma fluoride concentration, urinary fluoride excretion and fluoride renal clearance following no exercise and three exercise intensity conditions in nine healthy adults after taki...

  2. Scientific Opinion on Dietary Reference Values for fluoride

    Directory of Open Access Journals (Sweden)

    EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA

    2013-08-01

    Full Text Available Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA derived Dietary Reference Values (DRVs for fluoride, which are provided as Adequate Intake (AI from all sources, including non-dietary sources. Fluoride is not an essential nutrient. Therefore, no Average Requirement for the performance of essential physiological functions can be defined. Nevertheless, the Panel considered that the setting of an AI is appropriate because of the beneficial effects of dietary fluoride on prevention of dental caries. The AI is based on epidemiological studies (performed before the 1970s showing an inverse relationship between the fluoride concentration of water and caries prevalence. As the basis for defining the AI, estimates of mean fluoride intakes of children via diet and drinking water with fluoride concentrations at which the caries preventive effect approached its maximum whilst the risk of dental fluorosis approached its minimum were chosen. Except for one confirmatory longitudinal study in US children, more recent studies were not taken into account as they did not provide information on total dietary fluoride intake, were potentially confounded by the use of fluoride-containing dental hygiene products, and did not permit a conclusion to be drawn on a dose-response relationship between fluoride intake and caries risk. The AI of fluoride from all sources (including non-dietary sources is 0.05 mg/kg body weight per day for both children and adults, including pregnant and lactating women. For pregnant and lactating women, the AI is based on the body weight before pregnancy and lactation. Reliable and representative data on the total fluoride intake of the European population are not available.

  3. Uranium-liquid argon calorimetry: preliminary results from the DO tests

    International Nuclear Information System (INIS)

    The motivations for using uranium and liquid argon in sampling calorimetry are reviewed and the pros and cons of the technique are discussed. Preliminary results of the DO uranium-liquid argon test program are presented. 9 refs., 7 figs

  4. Irradiation effects on microhardness of fluoridated and non-fluoridated bovine dentin

    International Nuclear Information System (INIS)

    The objective of this study was to evaluate the effects of irradiation on microhardness of dentin. Dentin blocks from the cervical region of bovine incisors were treated as follows: 1) no irradiation; 2) irradiation of specimens up to 60 Gy (2Gy/day, 5 days/week); 3) no irradiation, but fluoridation of specimens for 5 min/d; 4) irradiation of specimens and daily fluoridation. Knoop hardness number (KHN) of the control specimens was 62.63±14.75 (mean±SD). This was significantly different from the irradiated dentin samples (8.74±2.59 KHN). Hardness of the fluoridated dentin specimens was 11.19±1.95 KHN in the non-irradiated group and 10.03±2.75 KHN in the irradiated groups, respectively. Within the limitations of an in vitro study, it is concluded that dentin is severely affected by irradiation. This could be an explanation for the frequently observed side-effects of irradiation like loss of enamel, gap formation at the amelodentinal junction, and caries of the cervical region. Fluoridation with acidic gels decereases microhardness of dentin surface, and does not prevent softening due to radiation, when saliva is absent. (au)

  5. Synthesis and characterization of ruthenium fluorides and oxide fluorides with high oxidation states

    International Nuclear Information System (INIS)

    The synthesis of ruthenium fluorides and oxide fluorides with high oxidation states was attempted from dioxide RuO2 and tetroxide RuO4. Three fluorinating agents were used: fluorine, chlorine trifluoride and krypton difluoride. The reactions were achieved in anhydrous hydrogen fluoride at room temperature. Thus, the reaction of RuO4 with CIF3 enabled us to prepare chloryl hexafluororuthenate (V), CIO2+ RuF6-, a new compound well identified by vibrational spectroscopy (infra-red and Raman), the structure of which was determined. The reaction of KrF2 with RuO4 gave the oxide tetrafluoride RuOF4, the previously published syntheses and properties of which were not in agreement with each other. This compound was definitely characterized here by chemical analysis, infra-red spectroscopy and X-ray powder diffraction. The product of thermal decomposition (700C) of RuOF4 is presumably RuF4 since only oxygen is liberated during this decomposition. At last, the reaction of KrF2 with RuO2 probably leads to the formation of the new oxide fluoride RuO2F4. Indeed, no oxygen is given off during this reaction, the chemical analysis of the red-orange coloured solid residue is almost in agreement with the one proposed and its infra-red absorption spectrum indicates the presence of ruthenium-oxygen and ruthenium-terminal and bridging fluorine bonds

  6. Synthesis and characterization of ruthenium fluorides and oxide fluorides with high oxidation states

    International Nuclear Information System (INIS)

    The synthesis of ruthenium fluorides and oxide fluorides with high oxidation states was attempted from dioxide RuO2 and tetroxide RuO4. Three fluorinating agents were used: fluorine, chlorine trifluoride and krypton difluoride. The reactions were achieved in anhydrous hydrogen fluoride at room temperature. Thus, the reaction of RuO4 with CIF3 enabled us to prepare chloryl hexafluororuthenate (V), ClO2+ RuF6-, a new compound well idendified by vibrational spectroscopy (infra-red and Raman), the structure of which was determined. The reaction of KrF2 with RuO4 gave the oxide tetrafluoride RuOF4, the previously published syntheses and properties of which were not in agreement with each other. This compound was definitely characterized here by chemical analysis, infra-red spectroscopy and X-ray powder diffraction. The product of thermal decomposition (700C) of RuOF4 is presumably RuF4 since only oxygen is liberated during this decomposition. At last, the reaction of KrF2 with RuO2 probably leads to the formation of the new oxide fluoride RuO2F4. Indeed, no oxygen is given off during this reaction, the chemical analysis of the red-orange coloured solid residue is almost in agreement with the one proposed and its infra-red absorption spectrum indicates the presence of ruthenium-oxygen and ruthenium-terminal and bridging fluorine bonds

  7. Method for decontamination of nickel-fluoride-coated nickel containing actinide-metal fluorides

    Science.gov (United States)

    Windt, N.F.; Williams, J.L.

    In one aspect, the invention comprises contacting nickel-fluoride-coated nickel with gaseous ammonia at a temperature effecting nickel-catalyzed dissociation thereof and effecting hydrogen-reduction of the nickel fluoride. The resulting nickel is heated to form a melt and a slag and to effect transfer of actinide metals from the melt into the slag. The melt and slag are then separated. In another aspect, nickel contianing nickel oxide and actinide metals is contacted with ammonia at a temperature effecting nickel-catalyzed dissociation to effect conversion of the nickel oxide to the metal. The resulting nickel is then melted and separated as described. In another aspect nickel-fluoride-coated nickel containing actinide-metal fluorides is contacted with both steam and ammonia. The resulting nickel then is melted and separated as described. The invention is characterized by higher nickel recovery, efficient use of ammonia, a substantial decrease in slag formation and fuming, and a valuable increase in the service life of the furnace liners used for melting.

  8. CAN FLUORIDATION AFFECT LEAD (II) IN POTABLE WATER? HEXAFLUOROSILICATE AND FLUORIDE EQUILIBRIA IN AQUEOUS SOLUTION

    Science.gov (United States)

    Recent reports have attempted to show that fluoridating potable water is linked to increased levels of lead(II) in the blood. We examine these claims in light of the established science and critically evaluate their significance. The completeness of hexafluorosilicate hydrolysi...

  9. Optical emission spectroscopy of argon and hydrogen-containing plasmas

    Science.gov (United States)

    Siepa, Sarah; Danko, Stephan; Tsankov, Tsanko V.; Mussenbrock, Thomas; Czarnetzki, Uwe

    2015-09-01

    Optical emission spectroscopy (OES) on neutral argon is applied to investigate argon, hydrogen and hydrogen-silane plasmas. The spectra are analyzed using an extensive collisional-radiative model (CRM), from which the electron density and the electron temperature (or mean energy) can be calculated. The CRM also yields insight into the importance of different excited species and kinetic processes. The OES measurements are performed on pure argon plasmas at intermediate pressure. Besides, hydrogen and hydrogen-silane plasmas are investigated using argon as a trace gas. Especially for the gas mixture discharges, CRMs for low and high pressure differ substantially. The commonly used line-ratio technique is found to lose its sensitivity for gas mixture discharges at higher pressure. A solution using absolutely calibrated line intensities is proposed. The effect of radiation trapping and the shape of the electron energy distribution function on the results are discussed in detail, as they have been found to significantly influence the results. This work was supported by the Ruhr University Research School PLUS, funded by Germany's Excellence Initiative [DFG GSC 98/3].

  10. High-frequency electrodeless lamps in argon-mercury mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Denisova, N [Institute of Theoretical and Applied Mechanics, Novosibirsk (Russian Federation); Revalde, G [Institute of Atomic Physics and Spectroscopy, University of Latvia, Raina blvd. 19, Riga (Latvia); Skudra, A [Institute of Atomic Physics and Spectroscopy, University of Latvia, Raina blvd. 19, Riga (Latvia); Zissis, G [CPAT, University Toulouse 3, 118 rte de Narbonne, 31062 Toulouse (France); Zorina, N [Institute of Atomic Physics and Spectroscopy, University of Latvia, Raina blvd. 19, Riga (Latvia)

    2005-09-07

    In this paper, numerical and experimental investigations of high-frequency (HF) electrodeless lamps in argon-mercury mixtures are performed. The intensities of the mercury spectral lines having wavelengths {lambda} = 404.66, 435.83, 546.07 nm (7{sup 3}S{sub 1}-6{sup 3}P{sub 0,1,2}) and the resonance line {lambda} = 253.7 nm (6{sup 3} P{sub 1}-6{sup 1}S{sub 0}) are measured at a wide range of mercury pressures, varying the HF generator current and argon filling pressure. A stationary self-consistent model of HF electrodeless discharge lamp is developed including kinetics of the excited mercury and argon atomic states. Based on the developed model, the radiation characteristics of the discharge plasma are calculated. Numerical simulation of the line intensities behaviour in dependence on the mercury pressure, HF generator current and argon filling pressure is performed. The model results are in qualitative agreement with the experimental data. The calculations of the relative intensities of the visible triplet lines 7{sup 3}S{sub 1}-6{sup 3}P{sub 0,1,2} are presented for the first time in this paper.

  11. Measurement of the argon plasma temperature by use of pyrometer

    International Nuclear Information System (INIS)

    The author describes in detail how to use pyrometer to measure the plasma temperature. The temperatures of shock-generated argon plasmas are given in the present work. Measured results of temperature-pressure curve are compared with calculated results using Saha-Debye-Huckel model, which are in good agreement

  12. LArGe. A liquid argon scintillation veto for GERDA

    International Nuclear Information System (INIS)

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 103 have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10-2 cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural 42Ar abundance (in parallel to Gerda), and have indication for the 2νββ-decay in natural germanium. (orig.)

  13. Study of Liquid Argon Dopants for LHC Hadron Calorimetry

    CERN Multimedia

    2002-01-01

    Hadron calorimetry based on the Liquid Argon Ionisation Chamber technique is one of the choice techniques for LHC-experimentation. A systematic study of the effect of selected dopants on Liquid Argon (LAr) will be carried out with the aim to achieve an improvement on: \\item (i)~``Fast Liquid Argon'' search and study of dopants to increase the drift velocity. It has been already shown that CH&sub4. added at a fraction of one percent increases the drift velocity by a factor of two or more. \\item (ii)~``Compensated Liquid Argon'' search and study of dopants to increase the response to densely ionising particles, resulting in improved compensation, such as photosensitive dopants. \\end{enumerate}\\\\ \\\\ Monitoring of the parameters involved in understanding the response of a calorimeter is essential. In case of doped LAr, the charge yield, the non-saturated drift velocity and the electron lifetime in the liquid should be precisely and simultaneously monitored as they all vary with the level of dopant concentrati...

  14. Aging tests of ethylene contaminated argon/ethane

    International Nuclear Information System (INIS)

    We report on aging tests of argon/ethane gas with a minor (1800 ppM) component of ethylene. The measurements were first conducted with the addition of alcohol to test the suppression of aging by this additive, with exposure up to ∼1.5 C/cm. Tests have included: a proportional tube with ethanol, another with isopropyl alcohol, and for comparison a tube has also been run with ethanol and argon/ethane from CDF's old (ethylene-free) ethane supply. The aging test with ethanol showed no difference between the ethylene-free and the ethylene tube. Furthermore, raw aging rates of argon/ethane and argon/ethane/ethylene were measured by exposing tubes without the addition of alcohol to about 0.1 C/cm. Again, no significant difference was observed. In conclusion, we see no evidence that ethylene contamination up to 1800 ppM has any adverse effect on wire aging. However, this level of ethylene does seem to significantly suppress the gas gain

  15. The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning

    International Nuclear Information System (INIS)

    The ATLAS liquid argon (LAr) calorimeter system consists of an electromagnetic barrel calorimeter and two end caps with electromagnetic, hadronic and forward calorimeters. The liquid argon sampling technique, with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the end cap (EMEC). The hadronic end cap calorimeter (HEC) uses a copper-liquid argon sampling technique with flat plate geometry and is subdivided in depth in two wheels per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules employing cylindrical electrodes with thin liquid argon gaps.The construction of the full calorimeter system is complete since mid-2004. Production modules constructed in the home institutes were integrated into wheels at CERN in 2003-2004, and inserted into the three cryostats. They passed their first complete cold test before the lowering into the ATLAS cavern. Results of quality checks (e.g. electrical, mechanical, ...) performed on all the 190304 read-out channels after cool down will be reported. End 2004 the ATLAS barrel electromagnetic (EM) calorimeter was installed in the ATLAS cavern and since summer 2005 the front-end electronics are being connected and tested. Results of this first commissioning phase will be shown to demonstrate the high standards of quality control for our detectors

  16. Investigation of non-equilibrium argon and hydrogen plasmas

    International Nuclear Information System (INIS)

    Theoretical and experimental investigations are made into non-equilibrium argon and hydrogen partially-ionized plasmas characteristic of glow-discharge devices such as thyratrons and discharge tubes. For an argon plasma, the development and use of a collisional-radiative, steady-state, three-energy-level model is presented, and experimental measurements on pulsed argon plasmas are briefly mentioned. Two different theoretical argon plasma models are discussed; the first is numerically solved using a non-Maxwellian electron distribution function, while the second is solved analytically, including atom-atom inelastic collisions, assuming Maxwellian electron and atom distribution functions. For a hydrogen plasma, experimental measurements using fluorescence and laser-induced fluorescence have been made in a modified hydrogen thyratron over a wide current density range (from 100 to 8000 A/cm2) for the atomic hydrogen population densities n = 2,3,4. A pronounced rise in the atomic hydrogen excited state populations is observed after the end of the current pulse. A new method to measure the time-resolved electron density was developed and results are presented

  17. X ray diagnostics of the argon filled dense plasma focus

    International Nuclear Information System (INIS)

    An experimental investigation has been conducted to use a Dense Plasma Focus Machine as a prospected high intensity pulsed x ray source. The argon was chosen for the plasma discharge. An effort to reach the highest x ray intensity emission has been made. Although it has not yet been possible to operate with as high energy in argon as in hydrogen, the argon focus provides an intensified ''point source'' of x ray. Based on the diagnostic data and the characteristic difference between argon and hydrogen, a theoretical model of the shock wave was proposed. The x ray energy spectrum of the focus was determined by a crystal spectrometer. Analyzing this spectrum, one can obtain a combined radiation from a 3 keV thermal plasma and a 48 keV electron beam bombarding the center electrode. The polarization of the x ray was measured at a direction perpendicular to the DPF axis. The change of the polarization with time indicated that the plasma impinged radially and then followed by an axial flow. The correlation of the x ray signal with the voltage signal showed that the plasma resistance was rising after the density reached its maximum, and associated the increase of the resistivity as a result of ion-acoustic instability

  18. Scattering of Slow Metastable Argon Atoms by Dielectric Nanospheres

    Science.gov (United States)

    Baudon, J.; Hamamda, M.; Grucker, J.; Perales, F.; Dutier, G.; Ducloy, M.; Bocvarski, V.

    2009-11-01

    The elastic scattering at low energy of metastable argon atoms with internal angular momentum J = 0 and 2 by dielectric nanospheres is investigated. The differential cross sections are calculated for both isotropic and anisotropic interactions. A polarization effect is clearly evidenced. The possible use of a metastable atom beam as a probe of an ensemble of nanospheres deposited on a passive substrate is examined.

  19. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  20. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  1. Laser-induced vibrational dynamics of ozone in solid argon

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; Amstrup, B.; Henriksen, Niels Engholm

    We consider the vibrational dynamics, induced by an intense infrared laser pulse, in an ozone molecule with isotopic substitution, that is, (OOO)-O-16-O-16-O-18 and compare the dynamics in the gas phase and in solid ar on. not perturbed by argon on a time-scale of a few picoseconds and selective...

  2. Experimental and numerical study of high intensity argon cluster beams

    International Nuclear Information System (INIS)

    Experimental and numerical investigations of expansion of argon with homogeneous condensation in supersonic conical nozzle and in free jet behind it were carried out. Optimal parameters (stagnation pressure, nozzle-skimmer distance) for the formation of cluster beam with maximum intensity were determined. Two available models for nonequilibrium nucleation were tested. The numerical results are in satisfactory agreement with the measured data

  3. Thermal decomposition of yttrium(III) valerate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Tang, Xiao; Pallewatta, Pallewatta G A P; Watenphul, A.; Zimmermann, M. v.

    2014-01-01

    The thermal decomposition of yttrium(III) valerate (Y(C4H9CO2)3) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction, in-situ synchrotron diffraction and hot-stage microscopy as well as room temperature optical microscopy. Melting...

  4. Turbulence and transport in a magnetized argon plasma

    International Nuclear Information System (INIS)

    An experimental study on turbulence and transport in the highly ionized argon plasma of a hollow cathode discharge is described. In order to determine the plasma parameters three standard diagnostics have been used, whilst two diagnostics have been developed to study the plasma turbulence. (Auth.)

  5. Study of a microwave discharge in argon/helium mixtures

    International Nuclear Information System (INIS)

    A discharge created by a surface wave in Argon-Helium mixture is studied. First, the helium influence on plasma parameters has been studied (electron density, electric field, effective collision frequency, etc...), then, on excitation processes in the discharge. Relations between plasma lines, electron density and electric field have been established

  6. Thermophysical properties of multi-shock compressed dense argon.

    Science.gov (United States)

    Chen, Q F; Zheng, J; Gu, Y J; Chen, Y L; Cai, L C; Shen, Z J

    2014-02-21

    In contrast to the single shock compression state that can be obtained directly via experimental measurements, the multi-shock compression states, however, have to be calculated with the aid of theoretical models. In order to determine experimentally the multiple shock states, a diagnostic approach with the Doppler pins system (DPS) and the pyrometer was used to probe multiple shocks in dense argon plasmas. Plasma was generated by a shock reverberation technique. The shock was produced using the flyer plate impact accelerated up to ∼6.1 km/s by a two-stage light gas gun and introduced into the plenum argon gas sample, which was pre-compressed from the environmental pressure to about 20 MPa. The time-resolved optical radiation histories were determined using a multi-wavelength channel optical transience radiance pyrometer. Simultaneously, the particle velocity profiles of the LiF window was measured with multi-DPS. The states of multi-shock compression argon plasma were determined from the measured shock velocities combining the particle velocity profiles. We performed the experiments on dense argon plasmas to determine the principal Hugonoit up to 21 GPa, the re-shock pressure up to 73 GPa, and the maximum measure pressure of the fourth shock up to 158 GPa. The results are used to validate the existing self-consistent variational theory model in the partial ionization region and create new theoretical models. PMID:24559345

  7. Thermal decomposition of yttrium(III) hexanoate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Suarez Guevara, Maria Josefina; Attique, Fahmida;

    2015-01-01

    The thermal decomposition of yttrium(III) hexanoate (Y(C5H11CO2)3)·xH2O in argon was studied by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction at a laboratory Cu-tube source and in-situ experiments at a synchrotron radiation source as well as hot...

  8. The role of metastable atoms in argon-diluted silane radiofrequency plasmas

    OpenAIRE

    Sansonnens, L.; Howling, A.A.; Hollenstein, C.; Dorier, J. L.; Kroll, U.

    2008-01-01

    The evolution of the argon metastable states density has been studied by absorption spectroscopy in power-modulated plasmas of argon and a mixture of 4% silane in argon. A small concentration of silane suppresses the argon metastable states density by molecular quenching. This molecular quenching adds to the electronic collisional dissociation to increase the silane dissociation rate as compared with pure silane plasmas. Using time-resolved emission spectroscopy, the role of metastable states...

  9. Potassium-Argon ages on mesozoic tholeutic dike Swarm in Rio Grande do Norte, Brazil

    International Nuclear Information System (INIS)

    Potassium-argon ages are reported for samples from four localities which represent three laterally separated Mesozoic tholeitic dikes in Precambrian oF Rio Grande do Norte, Brazil. The ages for the dikes are between 167 Ma and 130 Ma. It is shown that most of the ages determined are minimum ages due to argon losses. The methodological approach to identify argon losses is described. Ecess argon cannot be of significant influence on the ages found. (author)

  10. Conversion of an atomic to a molecular argon ion and low pressure argon relaxation

    Science.gov (United States)

    M, N. Stankov; A, P. Jovanović; V, Lj Marković; S, N. Stamenković

    2016-01-01

    The dominant process in relaxation of DC glow discharge between two plane parallel electrodes in argon at pressure 200 Pa is analyzed by measuring the breakdown time delay and by analytical and numerical models. By using the approximate analytical model it is found that the relaxation in a range from 20 to 60 ms in afterglow is dominated by ions, produced by atomic-to-molecular conversion of Ar+ ions in the first several milliseconds after the cessation of the discharge. This conversion is confirmed by the presence of double-Gaussian distribution for the formative time delay, as well as conversion maxima in a set of memory curves measured in different conditions. Finally, the numerical one-dimensional (1D) model for determining the number densities of dominant particles in stationary DC glow discharge and two-dimensional (2D) model for the relaxation are used to confirm the previous assumptions and to determine the corresponding collision and transport coefficients of dominant species and processes. Project supported by the Ministry of Education, Science and Technological Development of the Republic of Serbia (Grant No. ON171025).

  11. Optical restoration of irradiated lead fluoride crystals

    International Nuclear Information System (INIS)

    Due to its relatively high resistance to high radiation, lead fluoride (PbF2) crystals are becoming an increasingly popular material of choice for electromagnetic calorimetry, such as for experiments requiring the measurement of high-energy photons in Hall A of Jefferson Lab. For our studies we irradiated the PbF2 crystals using an electron linear accelerator (LINAC) followed by exposing the crystals to blue light so as to restore the nominal optical properties. This technique of optical bleaching with blue light affords an efficient and low-cost means for reversing the deleterious effects of optical transmission loss in radiation-damaged lead fluoride crystals. Whereas earlier experiments irradiated the PbF2 samples with 1.1 and 1.3 MeV γs from 60Co, we used pulsed beams of energetic electrons from the tunable 25-MeV LINAC at Idaho Accelerator Center of Idaho State University in Pocatello, Idaho. A 20-MeV beam of electrons was targeted onto four separate 19 cm length samples of lead fluoride over periods of 1, 2, and 4 hours yielding doses between 7 kGy and 35 kGy. Samples were then bleached with blue light of wavelength 410 - 450 nm for periods between 19.5 and 24 hours. We performed this process twice - radiation, bleaching, radiation, and then followed by bleaching again - for each of these four PbF2 samples. We shall discuss the efficacy of blue light curing on samples that have undergone two cycles of electron irradiation and optical bleaching

  12. Optical restoration of irradiated lead fluoride crystals

    International Nuclear Information System (INIS)

    Due to its relatively high resistance to high radiation, lead fluoride (PbF2) crystals are becoming an increasingly popular material of choice for electromagnetic calorimetry, such as for experiments requiring the measurement of high-energy photons in Hall A of Jefferson Lab. For our studies we irradiated the PbF2 crystals using an electron linear accelerator (LINAC) followed by exposing the crystals to blue light so as to restore the nominal optical properties. This technique of optical bleaching with blue light affords an efficient and low-cost means for reversing the deleterious effects of optical transmission loss in radiation-damaged lead fluoride crystals. Whereas earlier experiments irradiated the PbF2 samples with 1.1 and 1.3 MeV γs from 60Co, we used pulsed beams of energetic electrons from the tunable 25-MeV LINAC at Idaho Accelerator Center of Idaho State University in Pocatello, Idaho. A 20-MeV beam of electrons was targeted onto four separate 19 cm length samples of lead fluoride over periods of 1, 2, and 4 hours yielding doses between 7 kGy and 35 kGy. Samples were then bleached with blue light of wavelength 410 - 450 nm for periods between 19.5 and 24 hours. We performed this process twice - radiation, bleaching, radiation, and then followed by bleaching again - for each of these four PbF2 samples. We shall discuss the efficacy of blue light curing on samples that have undergone two cycles of electron irradiation and optical bleaching. (author)

  13. Optical Restoration of Lead Fluoride Crystals

    International Nuclear Information System (INIS)

    Due to its relatively high resistance to high radiation, lead fluoride (PbF2) crystals are becoming an increasingly popular material of choice for electromagnetic calorimetry, such as for experiments requiring the measurement of high-energy photons in Hall A of Jefferson Lab. For our studies we irradiated the PbF2 crystals using an electron linear accelerator (LINAC) followed by exposing the crystals to blue light so as to restore the nominal optical properties. This technique of optical bleaching with blue light affords an efficient and low-cost means for reversing the deleterious effects of optical transmission loss in radiation-damaged lead fluoride crystals. Whereas earlier experiments irradiated the PbF2 samples with 1.1 and 1.3 MeV gammas from 60Co, we used pulsed beams of energetic electrons from the tunable 25-MeV LINAC at Idaho Accelerator Center of Idaho State University in Pocatello, Idaho. A 20-MeV beam of electrons was targeted onto four separate 19 cm length samples of lead fluoride over periods of 1, 2, and 4 hours yielding doses between 7 kGy and 35 kGy. Samples were then bleached with blue light of wavelength 410-450 nm for periods between 19.5 and 24 hours. We performed this process twice - radiation, bleaching, radiation, and then followed by bleaching again - for each of these four PbF2 samples. We shall discuss the efficacy of blue light curing on samples that have undergone two cycles of electron irradiation and optical bleaching.

  14. Methods of controlling hydrogen fluoride pressure during chemical fabrication processes

    Science.gov (United States)

    Solovyov, Vyacheslav; Wiesmann, Harold

    2009-11-24

    The present invention is a method for producing a crystalline end-product. The method comprising exposing a fluoride-containing precursor to a hydrogen fluoride absorber under conditions suitable for the conversion of the precursor into the crystalline end-product.

  15. Fluoride and children's intelligence: a meta-analysis.

    Science.gov (United States)

    Tang, Qin-Qing; Du, Jun; Ma, Heng-Hui; Jiang, Shao-Jun; Zhou, Xiao-Jun

    2008-01-01

    This paper presents a systematic review of the literature concerning fluoride that was carried out to investigate whether fluoride exposure increases the risk of low intelligence quotient (IQ) in China over the past 20 years. MEDLINE, SCI, and CNKI search were organized for all documents published, in English and Chinese, between 1988 and 2008 using the following keywords: fluorosis, fluoride, intelligence, and IQ. Further search was undertaken in the website www.fluorideresearch.org because this is a professional website concerning research on fluoride. Sixteen case-control studies that assessed the development of low IQ in children who had been exposed to fluoride earlier in their life were included in this review. A qualitative review of the studies found a consistent and strong association between the exposure to fluoride and low IQ. The meta-analyses of the case-control studies estimated that the odds ratio of IQ in endemic fluoride areas compared with nonfluoride areas or slight fluoride areas. The summarized weighted mean difference is -4.97 (95%confidence interval [CI] = -5.58 to -4.36; p < 0.01) using a fixed-effect model and -5.03 (95%CI = -6.51 to 3.55; p < 0.01) using a random-effect model, which means that children who live in a fluorosis area have five times higher odds of developing low IQ than those who live in a nonfluorosis area or a slight fluorosis area. PMID:18695947

  16. Fluoride uptake from restorative dental materials by human enamel

    International Nuclear Information System (INIS)

    The purpose of the study was to determine the uptake in vitro of fluoride from restorative materials by tooth enamel and whether prior etching of the enamel causes a change of uptake. The outermost layer of the labial surface of extracted canines was removed by grinding and the enamel was covered with five different fluoride-containing materials ; a silicate, a composite resin, an amalgam, a silicophosphate, and a polycarboxylate luting cement. The material was either removed immediately or after storing the tooth in distilled water. The fluoride content was determined using a sensitive physical method based on the 19F (p, αγ) 16O reaction. In addition, the fluoride content of enamel after etching for different periods of time and of etched enamel which had been in contact with silicate cement was determined. The mean fluoride content of uncovered interior enamel was 226 parts 106. All materials, except the composite, increased clearly the fluoride content of the underlying enamel. Etching of interior enamel also increased the fluoride values. No difference could be shown in fluoride uptake from silicate and composite resin between etched and unetched enamel. (author)

  17. Computational investigation of the role of fluoride in Tamao oxidations

    DEFF Research Database (Denmark)

    Mader, Mary M.; Norrby, Per-Ola

    2002-01-01

    The Tamao oxidation of alkoxysilanes was investigated computationally to determine the role of fluoride. a key additive. in this reaction. A sequence of fluoride equilibria as well as possible transition states. mediated by basic and neutral peroxide, respectively, were examined, and a potential...

  18. Fluoride Analysis. Training Module 5.200.2.77.

    Science.gov (United States)

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with fluoride analysis procedures. Included are objectives, an instructor guide, student handouts, and a list of reference material. This module considers the determination of fluoride in water supplies using the SPANDS and electrode…

  19. Fluoride inhibits the response of bone cells to mechanical loading

    NARCIS (Netherlands)

    H.M.E. Willems; E.G.H.M. van den Heuvel; S. Castelein; J. Keverling Buisman; A.L.J.J. Bronckers; A.D. Bakker; J. Klein-Nulend

    2011-01-01

    The response of bone cells to mechanical loading is mediated by the cytoskeleton. Since the bone anabolic agent fluoride disrupts the cytoskeleton, we investigated whether fluoride affects the response of bone cells to mechanical loading, and whether this is cytoskeleton mediated. The mechano-respon

  20. Calculation of vapor pressure of fission product fluorides and oxyfluorides

    International Nuclear Information System (INIS)

    The equilibrium diagrams of the condensed phases - solid and liquid - and vapor phase are collected for the principal fluorides and oxyfluorides of fission product elements (atomic number from 30 to 66). These diagrams are used more particularly in fuel reprocessing by fluoride volatility process. Calculations and curves (vapor pressure in function of temperature) are processed using a computer program given in this report

  1. Electrorecovery of tantalum in molten fluorides

    International Nuclear Information System (INIS)

    Considering the privileged situation of Brazil as a productor of tantaliferous minerals, the authors have in view the development of a technology for production of metallic tantalum via molten salts electrolysis; this has the advantage of improving the aggregate value of exportation products, additionally to tantalum oxide and tantalum concentrates. Having in view the preliminary determintion of better conditions of temperature, electrolyte composition and current density for this process, electrolysis were conducted with a solvent composed of an eutetic mixture of lithium, sodium and potassium fluoride for dipotassium fluotantalate and occasionally for tantalum oxide. Current efficiencies as high as 83% were obtained in favoured conditions. (author)

  2. LUMINESCENCE IN POTENTIAL FLUORIDE GLASS LASERS

    OpenAIRE

    Jørgensen, C.

    1987-01-01

    Fluoride glasses of the zirconium barium lanthanide type (invented Rennes, 1975) and lead gallium zinc (or manganese) type (invented Le Mans, 1979) show luminescence of lanthanide J-Levels situated at least 2000 cm-1 above the closest lower level (this limit is a few times larger in most other materials). Not only is the non-radiative de-excitation as weak as incrystalline LaF3 (studied by Weber) but energy transfer between neodymium and ytterbium (III), or from manganese (II), and to some ex...

  3. Fluoride microresonators for mid-IR applications

    CERN Document Server

    Grudinin, Ivan S; Yu, Nan

    2016-01-01

    We study crystalline fluoride microresonators for mid-infrared applications. Whispering gallery mode resonators were fabricated with BaF$_2$, CaF$_2$ and MgF$_2$ crystals. The quality factors were measured at wavelengths of 1.56 {\\mu}m and 4.58 {\\mu}m. The impacts of fabrication technique, impurities, multiphonon absorption and surface water are investigated. It is found that MgF2 resonators have room temperature Q factor of $8.3\\times 10^6$ at wavelength of 4.58 {\\mu}m, limited by multiphonon absorption.

  4. Argon metastable dynamics and lifetimes in a direct current microdischarge

    Science.gov (United States)

    Stefanović, Ilija; Kuschel, Thomas; Schröter, Sandra; Böke, Marc

    2014-09-01

    In this paper we study the properties of a pulsed dc microdischarge with the continuous flow of argon. Argon metastable lifetimes are measured by tunable diode laser absorption spectroscopy (TDLAS) and are compared with calculated values which yield information about excitation and de-excitation processes. By increasing the gas flow-rate about 5 times from 10 to 50 sccm, the Arm lifetime increases from 1 to 5 μs due to the reduction of metastable quenching with gas impurities. Optical emission spectroscopy reveals nitrogen and water molecules as the main gas impurities. The estimated N2 density [N2] = 0.1% is too low to explain the measured metastable lifetimes. Water impurity was found to be the main de-excitation source of argon metastable atoms due to high quenching coefficients. The water impurity level of [H2O] = 0.15% to 1% is sufficient to bring calculated metastable lifetimes in line with experiments. The maximum value of water content in the discharge compared to the argon atoms is estimated to approximately 6%, due to the large surface to volume ratio of the microdischarge. The current pulse releases the water molecules from the electrode surface and they are either re-adsorbed in the time between 0.4 ms for [H2O] = 1% and 2.6 ms for [H2O] = 0.15% or pumped out of the discharge with the speed equal to the gas flow-rate. Depending on its partial pressure, the water impurity re-adsorption time is of the order of magnitude or less then the argon gas residence time.

  5. Observations of acoustic-wave-induced superluminescence in an argon plasma

    International Nuclear Information System (INIS)

    It is shown that in an argon discharge plasma it is possible to obtain overpopulation of certain electronic levels of atomic argon under the influence of acoustic waves. When the specified threshold is exceeded, then a superluminescence (in the form of light flashes) from the overpopulated electronic levels of atomic argon is observed

  6. 21 CFR 874.4490 - Argon laser for otology, rhinology, and laryngology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon laser for otology, rhinology, and laryngology. 874.4490 Section 874.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Argon laser for otology, rhinology, and laryngology. (a) Identification. The argon laser device for...

  7. Fluoride use in Controlling Dental Caries and Fluorosis

    Directory of Open Access Journals (Sweden)

    Gaurav Solanki

    2012-07-01

    Full Text Available Policy were introduced to control fluoride exposure and to reduce the prevalence of fluorosis. The study aimed of describing the prevalence, severity and risk factors for fluorosis, and to describe the trend of fluorosis among Indian children. The study also aimed of exploring the effect of the change in fluoride exposure on dental fluorosis and caries. Establishing an appropriate use of fluoride toothpaste could be successful in reducing fluorosis without a significant increase in caries experience. The use of fluorides for oral health has always involved a balance between the protective benefit against dental caries and the risk of developing fluorosis. The link between fluoride and dental health was established to determining the causes of dental fluorosis or enamel mottling. Fluorosis in Indian children was highly prevalent in the early 1990s.

  8. KINETICS OF SORPTION OF FLUORIDE ON CALCINED MAGNESITE IN BATCH

    DEFF Research Database (Denmark)

    Singano, J. J.; Mashauri, D. A.; Mtalo, F. W.;

    1997-01-01

    on first-order reaction with respect to the concentration of fluoride. The rate constant is directly proportional to the dosage. The model takes into accounts the lag time observed. The kinetical model can be described for any given dosage and initial fluoride concentration in the water. The reaction...... rate parameter, K, varies however slightly for different initial concentrations of fluoride in the water and different dosage of calcined magnesia. These relationships are described separately by two linear equations. It is discussed that the observed lag time is due to the fact that magnesia cannot......A series of sorption of fluoride on calcined magnesite are obtained from thermostatic pH-chemostat and jar test experiments. The fluoride removal is observed not to start instantly, as normal, but after a lag time of up to ½ an hour of contact time. A model for sorption kinetics is developed, based...

  9. Milk fluoridation for the prevention of dental caries

    Directory of Open Access Journals (Sweden)

    Jolán Bánóczy

    2013-11-01

    Full Text Available The aim of this review is to give an overview of 55 years experience of milk fluoridation and draw conclusions about the applicability of the method. Fluoridated milk was first investigated in the early 1950s, almost simultaneously in Switzerland, the USA and Japan. Stimulated by the favourable results obtained from these early studies, the establishment of The Borrow Dental Milk Foundation (subsequently The Borrow Foundation in England gave an excellent opportunity for further research, both clinical and non-clinical, and a productive collaboration with the World Health Organization which began in the early 1980s. Numerous peer-reviewed publications in international journals showed clearly the bioavailability of fluoride in various types of milk. Clinical trials were initiated in the 1980s – some of these can be classed as randomised controlled trials, while most of the clinical studies were community preventive programmes. Conclusion. These evaluations showed clearly that the optimal daily intake of fluoride in milk is effective in preventing dental caries. The amount of fluoride added to milk depends on background fluoride exposure and age of the children: commonly in the range 0.5 to 1.0 mg per day. An advantage of the method is that a precise amount of fluoride can be delivered under controlled conditions. The cost of milk fluoridation programmes is low, about € 2 to 3 per child per year. Fluoridation of milk can be recommended as a caries preventive measure where the fluoride concentration in drinking water is suboptimal, caries experience in children is significant, and there is an existing school milk programme.

  10. Caries prevention through the fluoridation of milk. A review.

    Science.gov (United States)

    Bánóczy, Jolán; Rugg-Gunn, Andrew J

    2007-10-01

    The aim of this review is to give an overview of 50 years experience of milk fluoridation and draw conclusions about the applicability of the method. Fluoridated milk was first investigated in the early 1950s, almost simultaneously in Switzerland, the USA and Japan. Stimulated by the favourable results obtained from these early studies, the establishment of The Borrow Dental Milk Foundation (subsequently The Borrow Foundation) in England gave an excellent opportunity for further research, both clinical and non-clinical, and a productive collaboration with the World Health Organization from the early 1980s onwards. Numerous peer-reviewed publications in international journals showed clearly the bioavailability of fluoride in milk, and increased concentrations of fluoride in saliva, dental plaque, dental enamel and dentine, and urine, after consumption of fluoridated milk. Clinical trials were initiated in the 1980s--some of these can be classed as randomised controlled trials, while most of the clinical studies were community preventive programs. These evaluations showed clearly that the optimal daily intake of fluoride in milk is effective in preventing dental caries. At present, milk fluoridation programs are running continuously in about ten countries of the world. Fluoridation of milk can be recommended as a caries preventive measure where the fluoride concentration in drinking water is suboptimal, caries experience in children is significant, and there is an existing school milk program. The program should aim to provide fluoridated milk for at least 200 days per year and should commence before the children are 4 years of age. PMID:18078140

  11. Fluoride-induced disruption of reproductive hormones in men

    International Nuclear Information System (INIS)

    Fluoride-induced reproductive effects have been reported in experimental models and in humans. However, these effects were found in heavily exposed scenarios. Therefore, in this work our objective was to study reproductive parameters in a population exposed to fluoride at doses of 3-27 mg/day (high-fluoride-exposed group--HFEG). Urinary fluoride levels, semen parameters, and reproductive hormones in serum (LH, FSH, estradiol, prolactin, inhibin-B, free and total testosterone) were measured. Results were compared with a group of individuals exposed to fluoride at lower doses: 2-13 mg/day (low-fluoride-exposed group-LFEG). A significant increase in FSH (P<0.05) and a reduction of inhibin-B, free testosterone, and prolactin in serum (P<0.05) were noticed in the HFEG. When HFEG was compared to LFEG, a decreased sensitivity was found in the FSH response to inhibin-B (P<0.05). A significant negative partial correlation was observed between urinary fluoride and serum levels of inhibin-B (r=-0.333, P=0.028) in LFEG. Furthermore, a significant partial correlation was observed between a chronic exposure index for fluoride and the serum concentrations of inhibin-B (r=-0.163, P=0.037) in HFEG. No abnormalities were found in the semen parameters studied in the present work, neither in the HFEG, nor in the LFEG. The results obtained indicate that a fluoride exposure of 3-27 mg/day induces a subclinical reproductive effect that can be explained by a fluoride-induced toxic effect in both Sertoli cells and gonadotrophs

  12. A modified fluoride reduction route for the preparation of thorium metal

    International Nuclear Information System (INIS)

    Thorium oxide is one of the most stable oxides known in nature. Commercially, thorium metal is produced by calciothermic reduction of its oxide. The process leads to the production of thorium powders, which if not handled carefully, can often lead to oxygen contamination in the final metal. In this paper, we report an alternative possibility of producing bulk thorium metal by calciothermic reduction of its fluorides. Fluoride being less hygroscopic and having higher boiling and melting point is preferred over the chloride intermediate. The process involves mixing of as prepared ThF4 and 20% excess calcium in a crucible in an argon environment and heating the charge to beyond the melting point of thorium. The heat of reaction during calcium reduction of thorium fluoride is not sufficient to increase the temperature of the reacted mass to above the melting points of the products. This is unlike the common metallothermic reduction process, viz. thermit process, in which both the products, the metal and the slag, melt due to the intense heat of the reaction and separate from each other due to density difference. The slag-metal separation in this process has to be ensured by heating the charge to above the melting point of the higher melting substance, otherwise a mixture of CaF2 and thorium metal would result. The reaction sequence of the process was studied by a visual observation. Besides, liquid thorium being very reactive, a proper choice of crucible material becomes important. In this paper, we describe our experiences on the interaction of liquid thorium with the crucible materials. In this work, we used two kind of crucibles: standard molybdenum crucibles and custom made fully dense yttria crucibles. Yttria crucibles of 25 mm dia and 85 mm length were specially made by Glass and Advanced Materials Division, Materials Group. An alternative route for production of metallic thorium is reported. The advantage in the process is that it can make thorium in bulk form

  13. Hydrogen Fluoride in the Local Universe

    Science.gov (United States)

    Monje, Raquel R.; Lis, Dariusz C.; Phillips, Thomas G.

    2015-01-01

    The Herschel Space Observatory has provided a unique opportunity to study hydride molecules with large rotational constant in the interstellar medium (ISM) within the nearby universe. Some of the key results from hydride studies with Herschel, and in particular with the Heterodyne Instrument for the Far-Infrared (HIFI), are the first detection at high spectral resolution of the fundamental J = 1 - 0 rotational transition of hydrogen fluoride (HF) at 1.232 THz, and the discovery of its ubiquitous nature within the ISM of the Milky Way galaxy and nearby galaxies. The remarkable Herschel/ HIFI results suggest, that the HF J = 1 - 0 transition promises to yield an extremely sensitive probe of the diffuse molecular gas along the lines of sight toward background far-infrared continuum sources and, as predicted earlier by chemical models, a valuable surrogate for molecular hydrogen in the nearby and high redshift universe. These and other interesting results on hydrogen fluoride from Herschel observations will be presented, as well as the results from follow-up studies from ground-base facilities on hydride molecules towards luminous lensed high-redshifted galaxies with strong submillimeter continuum.

  14. Polyvinylidene fluoride - a polymer as transducer material

    International Nuclear Information System (INIS)

    Polyvinylidene fluoride or PVDF is a flexible, thin piezo film and long chain semicrystalline polymer containing repeated of CH/sub 2/ - CH/sub 2/. In order to obtain desired piezoelectric properties PVDF is poled by subjecting it to high electric field. In poled PVDF piezoelectric constants have different values for each axis and one constant per axis. PVDF polymer exhibits generator and motor action. Usually 1000 A /sup o/ thick vacuum-deposited aluminum electrodes are formed on both sides of the sheet. Polymer material of PVDF can be used as a sensing element with temperature range of -40 /sup 0/ C to 100 /sup 0/C and a frequency range of 10/sup -3/ to 10/sup -9/ Hz. This paper includes as experimental observation of exciting aluminium open-ended tube at its resonance using PVDF transducer and maintained in this condition using phase lock loop or PLL. The tube is free to resonate when 9-micrometer thin polyvinylidene fluoride transducer is energized. It is observed that a film of such material can easily be used to produced the requisite vibrations in the tube. (author)

  15. Lanthanum fluoride nanoparticles for radiosensitization of tumors

    Science.gov (United States)

    Kudinov, Konstantin; Bekah, Devesh; Cooper, Daniel; Shastry, Sathvik; Hill, Colin; Bradforth, Stephen; Nadeau, Jay

    2016-03-01

    Dense inorganic nanoparticles have recently been identified as promising radiosensitizers. In addition to dose enhancement through increased attenuation of ionizing radiation relative to biological tissue, scintillating nanoparticles can transfer energy to coupled photosensitizers to amplify production of reactive oxygen species, as well as provide UVvisible emission for optical imaging. Lanthanum fluoride is a transparent material that is easily prepared as nanocrystals, and which can provide radioluminescence at a number of wavelengths through simple substitution of lanthanum ions with other luminescent lanthanides. We have prepared lanthanum fluoride nanoparticles doped with cerium, terbium, or both, that have good spectral overlap with chlorine6 or Rose Bengal photosensitizer molecules. We have also developed a strategy for stable conjugation of the photosensitizers to the nanoparticle surface, allowing for high energy transfer efficiencies on a per molecule basis. Additionally, we have succeeded in making our conjugates colloidally stable under physiological conditions. Here we present our latest results, using nanoparticles and nanoparticle-photosensitizer conjugates to demonstrate radiation dose enhancement in B16 melanoma cells. The effects of nanoparticle treatment prior to 250 kVp x-ray irradiation were investigated through clonogenic survival assays and cell cycle analysis. Using a custom apparatus, we have also observed scintillation of the nanoparticles and conjugates under the same conditions that the cell samples are irradiated.

  16. Luminescence in potential fluoride glass lasers

    International Nuclear Information System (INIS)

    Fluoride glasses of the zirconium barium lanthanide type (invented Rennes, 1975) and lead gallium zinc (or manganese) type (invented Le Mans, 1979) show luminescence of lanthanide J-Levels situated at least 2000 cm-1 above the closest lower level (this limit is a few times larger in most other materials). Not only is the non-radiative de-excitation as weaK as in crystalline LaF3 (studied by Weber) but energy transfer between neodymium and ytterbium(III), or from manganese(II), and to some extent from chromium(III), to luminescent J-levels of neodymium(III), erbium(III) and thullium(III) is highly efficient even at low concentrations. One advantage for laser applications is that the lowest quartet state of manganese(II) has a life-time 10 to 15 milliseconds (like in many phosphate glasses and crystalline compounds) allowing energy transfer, extending by huge factors the average life-time of the emitting J-levels. Though the tera-watt lasers (Livermore, California, 1978) inducing deuterium-tritium fusion are silicate glass containing neodymium(III), fluoride glasses should be preferable for many purposes. The evaluation of laser parameters from small-scale experimentation is feasible

  17. Method to determine argon metastable number density and plasma electron temperature from spectral emission originating from four 4p argon levels

    CERN Document Server

    Mariotti, Davide; Sasaki, Takeshi; Koshizaki, Naoto; 10.1063/1.2390631

    2010-01-01

    A simple model and method is proposed here to determine argon metastable number densities and electron temperature with the assumption of a Maxwell-Boltzmann electron energy distribution. This method is based on the availability of experimental relative emission intensities of only four argon lines that originate from any of the 4p argon levels. The proposed model has a relatively wide range of validity for laboratory plasmas that contain argon gas and can be a valuable tool for the emerging field of atmospheric microplasmas, for which diagnostics is still limited.

  18. EFFECTS OF ARGON ON THE PROPERTIES OF RF SPUTTERED AMORPHOUS SILICON

    OpenAIRE

    Shao-Qi, Peng; Qai, Yu; Xian, Zhang; Jing, Ye

    1981-01-01

    The Effects of argon on the properties of rf sputtered amorphous silicon film have been investigated. As the sputtering argon pressure is increased from 2 to 20 mTorr, the content of argon in the amorphous silicon film increases apparently (Argon/Silicon : from 10-2 to 5 x 10-2). The other properties measured as a function of argon pressure PAr show that as the PAr is increased, the photoconductivity, resistivity (300K), conductivity activation energy and optical gap increase also, while the ...

  19. Surface Modification of Polyvinylidene Fluoride(PVDF)Membranes by Low-Temperature Plasma with Grafting Styrene

    Institute of Scientific and Technical Information of China (English)

    CHEN Jian; LI Jiding; CHEN Cuixian

    2009-01-01

    In order to control the surface pore sizes of polyvinylidene fluoride membranes and their distribution.low temperature plasma-induced grafting modifications of PVDF were studied to prepare hydrophobe membranes.By argon(Ar)treating and subsequent grafting reaction,a hydrophobe monomer,styrene,was introduced into the PVDF membrane.Fourier transform infrared attenuated total reflection (FTIR-ATR) was utilized to characterize the chemical and Physical changes in the Ar plasma modified membrane.The surface modifications of PVDF membranes were investigated by using scanning electron microscopy(SEM),atomic force microscopy(AFM) and differential scanning calorimeter(DSC).The water permeability and the solute rejection were measured by PVDF membrane modified in different graft conditions.Results demonstrated that he pores in the modified membranes get smaller and the distribution of pores gets narrowed with the increase in grafting reaction duration.Longer graft time caused the water flux of PVDF membrane to decrease from 578 kg/(m2·h)to 23 kg/(m2·h)and the solute rejection to increase from 73%to 92%.

  20. First Commissioning of a Cryogenic Distillation Column for Low Radioactivity Underground Argon

    CERN Document Server

    Back, Henning O; Alton, Andrew; Condon, Christopher; de Haas, Ernst; Galbiati, Cristiano; Goretti, Augusto; Hohmann, Tristan; Ianni, Andrea; Kendziora, Cary; Loer, Ben; Montanari, David; Mosteiro, Pablo; Pordes, Stephen

    2012-01-01

    We report on the performance and commissioning of a cryogenic distillation column for low radioactivity underground argon at Fermi National Accelerator Laboratory. The distillation column is designed to accept a mixture of argon, helium, and nitrogen and return pure argon with a nitrogen contamination less than 10 ppm. In the first commissioning, we were able to run the distillation column in a continuous mode and produce argon that is 99.9% pure. After running in a batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The efficiency of collecting the argon from the gas mixture was between 70% and 81%, at an argon production rate of 0.84-0.98 kg/day.

  1. Synthesis of nanocrystalline mixed metal fluorides in nonaqueous medium

    Indian Academy of Sciences (India)

    Neetu Tyagi; Epsita Ghanti; Nikesh Gupta; N P Lalla; Rajamani Nagarajan

    2009-12-01

    Synthesis of mixed metal fluorides of the general formula, KMF3 (M = Mg, Mn, Co, Ni, Cu and Zn), possessing perovskite structure was investigated in non-aqueous medium. The fluorides were characterized by powder X-ray diffraction, FT–IR spectroscopy, thermal analysis, SEM and TEM. Monophasic cubic phases were obtained for the central metal ions such as Mg, Mn, Co, Ni, and Zn and a tetragonally distorted phase was observed for Cu. The usage of non-aqueous medium is advantageous for the bulk synthesis of these fluorides, since it eliminated the generation and handling of the hazardous HF that has usually been encountered during aqueous preparations. The average crystallite size of the fluorides obtained by this approach was estimated to be in the range of 9–30 nm. SEM micrographs of KZnF3 showed cubic morphology of perovskite phases. TEM studies on KCuF3 confirmed the presence of tetragonal distortion. The fluoride content was determined by titrimetry and found to be nearly stoichiometric. Some of these fluorides were found to be thermally stable up to 225°C in air. These fluorides were employed as fluorinating agents in organic fluorination reactions, thereby suggesting their possible utilization for selective fluorination of aliphatic and aromatic hydrofluorocarbons (HFCs) that are industrially relevant.

  2. Fluoride Levels of Mothers' Breast Milk in Egypt

    Directory of Open Access Journals (Sweden)

    Ghada, Z A Soliman and Tamer M M Saad

    2012-01-01

    Full Text Available Introduction: Fluoride exists naturally in water sources and is derived from fluorine. It is well known that fluoride helps, prevent and even reverse the early stages of tooth decay. Aim: The aim of the present study was to determine the fluoride levels in plasma and breast milk of lactating mothers in Egypt (Cairo and Giza Governorate. Material and Methods: Two hundred healthy lactating mothers aged between 20-40 years old were asked to give plasma and milk samples voluntary. Breast milk samples were directly refrigerated until measurements. The fluoride concentrations of plasma, milk and drinking tap water were assessed using an ion-selective fluoride electrode combined with an ion analyzer. Results: The fluoride levels of plasma, breast milk and drinking tap water samples were 0.0207±0.012, 0.0111±0.0044 ppm, and 0.482±0.117 ppm, respectively. A significant direct correlation between fluoride content in breast milk and drinking tap water was found (r=0.858, p< 0.01.

  3. [Experience with argon laser in urological diseases (author's transl)].

    Science.gov (United States)

    Rothauge, C F; Nöske, H D; Kraushaar, J

    1981-09-01

    The application of the Argon laser in urology has proved to be effective in resecting recurrent, exophytic urothelial tumors of the bladder up to the size of a raspberry. In cases of wide spread bladder tumors we only perform a radiation of the resected area as local recurrence prophylaxis following transurethral resection. The urethroscopic Argon laser irradiation makes laser urethrotomy and evaporisation of urethral strictures possible. Furthermore, a curative and conservative treatment of urethral tumors is possible in combination with chemotherapy. The same applies for the penis carcinoma. Urethral ruptures are also successfully treated by urethroscopic laser recanalization. A determination of the ureteral submucosal course, which may allow a prognosis about the probable maturation, is possible in cases of cystoureteral reflux with the help of laser diaphanoscopy. PMID:7197839

  4. Development of cryogenic installations for large liquid argon neutrino detectors

    CERN Document Server

    Adamowski, M; Geynisman, M; Hentschel, S; Montanari, D; Nessi, M; Norris, B

    2015-01-01

    A proposal for a very large liquid argon (68,000 kg) based neutrino detector is being studied. To validate the design principles and the detector technology, and to gain experience in the development of the cryostats and the cryogenic systems needed for such large experiments, several smaller scale installations will be developed and implemented, at Fermilab and CERN. The cryogenic systems for these installations will be developed, constructed, installed and commissioned by an international engineering team. These installations shall bring the required cooling power under specific conditions to the experiments for the initial cool-down and the long term operation, and shall also guarantee the correct distribution of the cooling power within the cryostats to ensure a homogeneous temperature distribution within the cryostat itself. The cryogenic systems shall also include gaseous and liquid phase argon purification devices to be used to reach and maintain the very stringent purity requirements needed for these...

  5. Measurement of longitudinal electron diffusion in liquid argon

    Science.gov (United States)

    Li, Yichen; Tsang, Thomas; Thorn, Craig; Qian, Xin; Diwan, Milind; Joshi, Jyoti; Kettell, Steve; Morse, William; Rao, Triveni; Stewart, James; Tang, Wei; Viren, Brett

    2016-04-01

    We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data analysis are described. In the region between 100 and 350 V/cm, our results show a discrepancy with the previous measurement [1]. In the region between 350 and 2000 V/cm, our results represent the world's best measurement. Over the entire measured electric field range, our results are systematically higher than the calculation of Atrazhev-Timoshkin [2]. The quantum efficiency of the gold photocathode, the drift velocity and longitudinal diffusion coefficients in gas argon are also presented.

  6. Evaporation and condensation at a liquid surface. I. Argon

    Science.gov (United States)

    Yasuoka, Kenji; Matsumoto, Mitsuhiro; Kataoka, Yosuke

    1994-11-01

    Molecular dynamics computer simulations were carried out to investigate the dynamics of evaporation and condensation for argon at the temperature of 80 and 100 K. From the decrease of the survival probability of vapor molecules, the ratio of self reflection to collision is estimated to be 12%-15%, only weakly dependent on the temperature. This suggests that argon vapor molecules are in the condition of almost complete capture, and the condensation is considered to be a barrierless process. The total ratio of reflection which is evaluated with the flux correlation of condensation and evaporation is 20% at both temperature. The difference between these two ratios of reflection is ascribed to a phenomenon that vapor molecules colliding with the surface drive out other liquid molecules. This molecule exchange at the surface is as important as the self-reflection, and the conventional picture of condensation as a unimolecular chemical reaction is not appropriate.

  7. Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator

    International Nuclear Information System (INIS)

    Background. Distal migration is one of the common complications after insertion of a covered metallic stent. Stent repositioning or removal is not always possible in every patient. Therefore, trimming using an argon plasma coagulator (APC) may be a good alternative method to solve this problem. Methods. Metallic stent trimming by APC was performed in 2 patients with biliary Wallstent migration and in another patient with esophageal Ultraflex stent migration. The power setting was 60-100 watts with an argon flow of 0.8 l/min. Observations. The procedure was successfully performed and all distal parts of the stents were removed. No significant collateral damage to the nearby mucosa was observed. Conclusions. In a patient with a distally migrated metallic stent, trimming of the stent is possible by means of an APC. This new method may be applicable to other sites of metallic stent migration

  8. Narrow spectral width laser diode for metastable argon atoms pumping

    Science.gov (United States)

    Gao, Jun; Li, Bin; Wang, Xinbing; Zuo, Duluo

    2016-03-01

    Diode laser pump source with narrow emitting spectrum for optically pumped metastable rare gas laser (OPRGL) of argon was achieved by employing a complex external cavity coupled with volume Bragg grating (VBG). A commercially available c-mount laser diode with rated power of 6 W was used and studied in both the free running mode and VBG external cavity. The maximum output power of 3.9 W with FWHM less than 25 pm and peak wavelength locked around 811.53 nm was obtained from the VBG external cavity laser diode. Precise control of VBG temperature enabled fine tuning of the emission wavelength over a range of 450 pm. Future researches on OPRGL of argon will benefit from it.

  9. Scintillation time dependence and pulse shape discrimination in liquid argon

    International Nuclear Information System (INIS)

    Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid argon down to 5 keVee. We develop two methods of pulse shape discrimination to distinguish between electronic and nuclear recoils. Using one of these methods, we measure a background- and statistics-limited level of electronic recoil contamination to be 7.6x10-7 between 52 and 110 keV of nuclear recoil energy (keVr) for a nuclear recoil acceptance of 50% with no nuclear recoil-like events above 62 keVr. Finally, we develop a maximum likelihood method of pulse shape discrimination based on the measured scintillation time dependence

  10. Demonstration of a Lightguide Detector for Liquid Argon TPCs

    CERN Document Server

    Bugel, L; Ignarra, C; Jones, B J P; Katori, T; Smidt, T; Tanaka, H -K

    2011-01-01

    We report demonstration of light detection in liquid argon using an acrylic lightguide detector system. This opens the opportunity for development of an inexpensive, large-area light collection system for large liquid argon time projection chambers. The guides are constructed of acrylic, with TPB embedded in a surface coating with a matching index of refraction. We study the response to early scintillation light produced by a 5.3 MeV alpha. We measure coating responses from 7 to 8 PE on average, compared to an ideal expectation of 10 PE on average. We estimate the attenuation length of light along the lightguide bar to be greater than 0.5 m. The coating response and the attenuation length can be improved; we show, however, that these results are already sufficient for triggering in a large detector.

  11. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  12. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.;

    1981-01-01

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore unequivo......The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...... unequivocally associated with electronic processes generated by the bombarding particle. In the present energy region, it is found that Y scales approximately as the electronic stopping power squared, depends on the charge state of the incoming helium ions, and perhaps more important, is independent of the...

  13. Readiness of the ATLAS Liquid Argon Calorimeter for LHC Collisions

    CERN Document Server

    Aad, G; Abdallah, J; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abramowicz, H; Abreu, H; Acharya, B S; Adams, D L; Addy, T N; Adelman, J; Adorisio, C; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahmed, H; Ahsan, M; Aielli, G; Akdogan, T; Åkesson, T P A; Akimoto, G; Akimov, A V; Aktas, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alviggi, M G; Amako, K; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Andeen, T; Anders, C F; Anderson, K J; Andreazza, A; Andrei, V; Anduaga, X S; Angerami, A; Anghinolfi, F; Anjos, N; Antonaki, A; Antonelli, M; Antonelli, S; Antunovic, B; Anulli, F; Aoun, S; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Archambault, J P; Arfaoui, S; Arguin, J-F; Argyropoulos, T; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnault, C; Artamonov, A; Arutinov, D; Asai, M; Asai, S; Asfandiyarov, R; Ask, S; Åsman, B; Asner, D; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Atoian, G; Auerbach, B; Auge, E; Augsten, K; Aurousseau, M; Austin, N; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Baccaglioni, G; Bacci, C; Bach, A; Bachacou, H; Bachas, K; Backes, M; Badescu, E; Bagnaia, P; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baltasar Dos Santos Pedrosa, F; Banas, E; Banerjee, P; Banerjee, S; Banfi, D; Bangert, A; Bansal, V; Baranov, S P; Baranov, S; Barashkou, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baron, S; Baroncelli, A; Barr, A J; Barreiro, F; BarreiroGuimarães da Costa, J; Barrillon, P; Barros, N; Bartoldus, R; Bartsch, D; Bastos, J; Bates, R L; Bathe, S; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Bazalova, M; Beare, B; Beau, T; Beauchemin, P H; Beccherle, R; Becerici, N; Bechtle, P; Beck, G A; Beck, H P; Beckingham, M; Becks, K H; Bedajanek, I; Beddall, A J; Beddall, A; Bednár, P; Bednyakov, V A; Bee, C; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Belotskiy, K; Beltramello, O; Ben Ami, S; Benary, O; Benchekroun, D; Bendel, M; Benedict, B H; Benekos, N; Benhammou, Y; Benincasa, G P; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Beretta, M; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernardet, K; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertin, A; Besson, N; Bethke, S; Bianchi, R M; Bianco, M; Biebel, O; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J-B; Blanchot, G; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bocci, A; Boehler, M; Boek, J; Boelaert, N; Böser, S; Bogaerts, J A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Boldyrev, A; Bondarenko, V G; Bondioli, M; Boonekamp, M; Booth, J R A; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borroni, S; Bos, K; Boscherini, D; Bosman, M; Bosteels, M; Boterenbrood, H; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boulahouache, C; Bourdarios, C; Boyd, J; Boyko, I R; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Breton, D; Brett, N D; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Brooijmans, G; Brooks, W K; Brown, G; Brubaker, E; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Bucci, F; Buchanan, J; Buchholz, P; Buckley, A G; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Byatt, T; Caballero, J; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Camarri, P; Cambiaghi, M; Cameron, D; Campabadal-Segura, F; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans-Garrido, M D M; Caprini, I; Caprini, M; Capua, M; Caputo, R; Caracinha, D; Caramarcu, C; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carrillo Montoya, G D; Carron Montero, S; Carter, A A; Carter, J R

    2010-01-01

    The ATLAS liquid argon calorimeter has been operating continuously since August 2006. At this time, only part of the calorimeter was readout, but since the beginning of 2008, all calorimeter cells have been connected to the ATLAS readout system in preparation for LHC collisions. This paper gives an overview of the liquid argon calorimeter performance measured in situ with random triggers, calibration data, cosmic muons, and LHC beam splash events. Results on the detector operation, timing performance, electronics noise, and gain stability are presented. High energy deposits from radiative cosmic muons and beam splash events allow to check the intrinsic constant term of the energy resolution. The uniformity of the electromagnetic barrel calorimeter response along eta (averaged over phi) is measured at the percent level using minimum ionizing cosmic muons. Finally, studies of electromagnetic showers from radiative muons have been used to cross-check the Monte Carlo simulation. The performance results obtained u...

  14. Amelioration of Fluoride Toxicity with the Use of Indigenous Inputs

    Directory of Open Access Journals (Sweden)

    Maitra A.

    2013-08-01

    Full Text Available An assessment was undertaken to study the efficacy of bacterial consortia isolated from different sources viz. rhizosphere of rice plant, oil spill sites of a petrol pump and from the sludge of a pharmaceutical waste water drain against the impact of fluoride. The experiments were conducted with two crops. In this mung bean experiment Vigna radiata was selected as a test crop. The seeds were sown in the field with bacterial consortia, compost and reduced dose (25% less nitrogen than recommended dose of chemical fertilizer. After 30days of seed sowing (DAS, plants were collected from the field and dipped into the sodium fluoride solution with different concentrations for 48 hours. Thereafter, the impact of fluoride on chlorophyll, sugar, proline and relative water content (% were evaluated. Scanning electron microscopy (SEM of the stem section was performed. SEM studies revealed that anatomical structure deformed with 1.5 mg/l sodium fluoride solution. It was observed that such treatment combination during the sowing of crops leads to combat the impact of lower doses of sodium fluoride (0.2 mg/l. Another experiment was also conducted within plastic pots with and without bacterial consortia isolated from rhizosphere of rice plant and oil spilled soil of petrol pump with the same field soil. Each pot was filled with 5 kg of soil + 2lt of water (on the basis of soil saturation. Oryza sativa seedlings were transplanted with different strength of sodium fluoride solution (25 mgNaF/kg, 50 mgNaF/kg, 100 mgNaF/kg and 500mgNaF/kg within the above pots. In second experiment, rice plants dried in all pots after 500 mgNaF/kg concentration of sodium fluoride. In this pot experiment bacterial strain are capable of reducing fluoride content in soil as noted by measuring fluoride in the pot soil after the experiment.

  15. Fluoride and lead adsorption on carbon nanotubes

    Institute of Scientific and Technical Information of China (English)

    WANG Shuguang; LI Yanhui

    2004-01-01

    The properties and applications of CNT have been studied extensively since Iijima discovered them in 1991[1,2]. They have exceptional mechanical properties and unique electrical property, highly chemical stability and large specific surface area. Thus far, they have widely potential applications in many fields. They can be used as reinforcing materials in composites[3], field emissions[4], hydrogen storage[5], nanoelectronic components[6], catalyst supports[7], adsorption material and so on. However, the study on the potential application of CNT, environmental protection field in particular, was hardly begun.Long[8] et al. reported that CNT had a significantly higher dioxin removal efficiency than that of activated carbon. The Langmuir adsorption constant is 2.7 × 1052, 1.3 × 1018 respectively. The results indicated that CNT is potential candidate for the removal of micro-organic pollutants. However, the reports on the CNT used as fluoride and heavy metal adsorbent are seldom.In this paper, A novel material, alumina supported on carbon nanotubes (Al2O3/CNT), was prepared from carbon nanotubes and Al(NO3)3. X-ray diffraction (XRD) spectra demonstrate that alumina is amorphous, and scanning electron microscope (SEM) images show that CNT and alumina are homogeneously mixed. Furthermore, the fluoride adsorption behavior on the surface of Al2O3/CNT has been investigated and compared with other adsorbents. The results indicate that Al2O3/CNT has a high adsorption capacity, with a saturation adsorption capacity of 39.4 mg/g. It is also found that the adsorption capacity of Al2O3/CNT is 3.0~4.5 times that of γ-Al2O3while almost equal to that of IRA-410 polymeric resin at 25 ℃. The adsorption isotherms of fluoride on Al2O3/CNT is fit the Freundlich equation well, optimal pH ranging from 5.0 to 9.0.Also in this paper, a novel material, modified carbon nanotubes (CNT), was prepared from carbon nanotubes and HNO3 under boiling condition. Infrared spectroscopy (IR

  16. Pharmacokinetics of Fluoride in Toddlers After Application of 5% Sodium Fluoride Dental Varnish

    OpenAIRE

    Milgrom, Peter; Taves, Donald M.; Kim, Amy S.; Watson, Gene E; Jeremy A Horst

    2014-01-01

    The prevalence of dental caries (tooth decay) among preschool children is increasing, driven partially by an earlier age of onset of carious lesions. The American Academy of Pediatrics recommends application of 5% sodium fluoride varnish at intervals increasing with caries risk status, as soon as teeth are present. However, the varnishes are marketed for treatment of tooth sensitivity and are regulated as medical devices rather than approved by the US Food and Drug Administration for preventi...

  17. Separation of volatile fluorides by selective desorption from granular inorganic fluorides

    International Nuclear Information System (INIS)

    Problems posed by the theory of gas mixtures separation by the method of selective desorption of components as applied to purification of uranium hexafluoride from some volatile impurity fluorides, i.e. WF6, MoF6, HF, are stated. Examples of calculation of WF6 - MoF6 mixture separation factor, as well as of composition of MoF6 stripping, depending on the composition of the initial WF6 - MoF6 mixture, are provided

  18. Electron Neutrino Classification in Liquid Argon Time Projection Chamber Detector

    OpenAIRE

    Płoński, Piotr; Stefan, Dorota; Sulej, Robert; Zaremba, Krzysztof

    2015-01-01

    Neutrinos are one of the least known elementary particles. The detection of neutrinos is an extremely difficult task since they are affected only by weak sub-atomic force or gravity. Therefore large detectors are constructed to reveal neutrino's properties. Among them the Liquid Argon Time Projection Chamber (LAr-TPC) detectors provide excellent imaging and particle identification ability for studying neutrinos. The computerized methods for automatic reconstruction and identification of parti...

  19. Unified set of atomic transition probabilities for neutral argon

    OpenAIRE

    Wiese, W.; Brault, J.; Danzmann, K.; Helbig, V.; de Kock, M

    1989-01-01

    The atomic transition probabilities and radiative lifetimes of neutral argon have been the subject of numerous experiments and calculations, but the results exhibit many discrepancies and inconsistencies. We present a unified set of atomic transition probabilities, which is consistent with essentially all recent results, albeit sometimes only after critical reanalysis. The data consistency and scale confirmation has been achieved in two ways. (i) We have carried out some lifetime–branching-ra...

  20. Operational performance of a large liquid argon photon calorimeter

    International Nuclear Information System (INIS)

    We describe the performance of a large (0.9x1.4 m2) liquid argon photon calorimeter in high energy experiments at Fermilab. Resolutions for π0 and electron showers, obtained under data-taking conditions, are compared with electron-beam calibration results. Exceptional spatial and time resolutions have been achieved for isolated showers (sigmasub(x,y)0 data up to 180 GeV are presented. (orig.)

  1. Changes in colour contrast sensitivity associated with operating argon lasers.

    OpenAIRE

    Gündüz, K; Arden, G B

    1989-01-01

    A new test of colour vision using computer graphics has been used to obtain quantitative estimates of colour contrast sensitivity in ophthalmologists before and after they have treated patients by argon laser retinal photocoagulation. The colour vision of all subjects is normal when tested with the 100-hue test and HRR (Hardy, Rittler, Rand) plates, but colour contrast sensitivity measured along a tritan colour confusion line is selectively impaired after a treatment session. No such change o...

  2. Influence of argon pollution on the weld surface morphology

    OpenAIRE

    Krolczyk, G.M.; Nieslony, P.; Krolczyk, J.B.; I. Samardzic; Legutko, S.; S. Hloch; Barrans, Simon; Maruda, R.W.

    2015-01-01

    In this paper the surfaces of butt welded joints in steel tubes were analyzed using an optical 3D measurement system to determine the morphology and topographic parameters. It was established that pollution of the argon shield gas with oxygen did not influence the width of the heat-affected zone. However, the composition of the shield gas significantly influenced the surface asymmetry, Ssk, and its inclination Sku. The measurement of these parameters enabled the selection of a ...

  3. Experimental Investigation of Low Pressure Audio Frequency Discharge in Argon

    International Nuclear Information System (INIS)

    Experimental data obtained on audio frequency (100–10000 Hz) discharge in argon at four pressures 50, 60, 70, and 80 mTorr are presented. The data show significant changes of the discharge current waveform with frequency. These changes seem to be associated with the glow discharge profile and colour. An empirical model based on the assumption of a frequency-dependent breakdown voltage is used to describe the experimental data

  4. STATUS OF THE ATLAS LIQUID ARGON CALORIMETER AND ITS PERFORMANCE

    CERN Document Server

    Berillari, T; The ATLAS collaboration

    2011-01-01

    The liquid argon (LAr) calorimeters are used in ATLAS for all electromagnetic and for hadron calorimetry. The LAr calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic, hadronic and forward calorimeters. The latest status of the detector as well as problems and solutions addressed during the last years will be presented. Aspects of operation of a large detector over a long time period will be summarized and selected topics showing the performance of the detector will be shown.

  5. Thermal decomposition of lanthanum(III) butyrate in argon atmosphere

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Xiao, Tang;

    2013-01-01

    The thermal decomposition of La(C3H7CO2)3·xH2O (x≈0.82) was studied in argon during heating at 5K/min. After the loss of bound H2O, the anhydrous butyrate presents at 135°C a phase transition to a mesophase, which turns to an isotropic liquid at 180°C. The decomposition of the anhydrous butyrate ...

  6. Argon laser photocoagulation of cyclodialysis clefts after cataract surgery

    International Nuclear Information System (INIS)

    Three patients with cyclodialysis clefts, hypotony and hypotonic retinopathy subsequent to cataract surgery were treated with argon laser photocoagulation. The hypotony was reversed in each patient and their visual acuity was normalized. Laser photocoagulation is a noninvasive treatment that can be repeated easily and safely. The complications of the treatment are minor. A hypertensive episode commonly occurs in the early postoperative period. (au) 8 refs

  7. Spectroscopy of Argon Excited in an Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E

    2005-04-18

    Argon is one of the gases best investigated and most widely used in plasma discharge devices for a multitude of applications that range from wavelength reference standards to controlled fusion experiments. Reviewing atomic physics and spectroscopic problems in various ionization stages of Ar, the past use and future options of employing an electron beam ion trap (EBIT) for better and more complete Ar data in the x-ray, EUV and visible spectral ranges are discussed.

  8. Spectroscopic Investigations of Air Entrainment into an Argon Plasma Jet

    Czech Academy of Sciences Publication Activity Database

    Hlína, Jan; Něnička, Václav; Šlechta, Jiří; Krejčí, Luděk; Dolínek, Vladimír; Sopuch, Pavel

    Vol. 3. Orléans : GREMI, CNRS/University of Orléans, 2001 - (Bouchoule, A.; Pouvesle, J.), s. 1107-1110 [INTERNATIONAL SYMPOSIUM ON PLASMA CHEMISTRY /15./. Orléans (FR), 09.07.2001-13.07.2001] R&D Projects: GA AV ČR IAA1057001; GA ČR GA202/99/0389 Keywords : nitrogen molecular bands * dependence of nitrogen radiations on the argon flow rate Subject RIV: BL - Plasma and Gas Discharge Physics

  9. Fluoride reactions with dental enamel following different forms of fluoride supply

    International Nuclear Information System (INIS)

    The reactions with dental enamel of NaF as tablets dissolved in different beverages or supplied with NaCl, simulating domestic salt fluoridation, were studied in tests with enamel surfaces and enamel powder. It was confirmed that powdered enamel can react quite differently from enamel surfaces under certain conditions. Enamel surfaces took up much more fluoride (F) from orange juice than from water or milk, and neither the low pH nor the citrate content of the juice increased the formation of unstable CaF2 in the enamel, as judged from a KOH leaching test. The F uptake by enamel surfaces from 0.25 mM NaF in 175 mM NaCl, corresponding to a dish prepared with salt containing 500 parts/106 F, was about 80 percent greater than from the same NaF concentration in water. This NaCl concentration did not increase the formation of CaF2 in the enamel, as judged from the KOH test, while 350 mM NaCl caused a moderate increase. The investigations support the administration of NaF tablets with orange juice and the plans for domestic salt fluoridation. (author)

  10. Determination of fluoride with thorium nitrate by catalytic titration

    International Nuclear Information System (INIS)

    Amperometry, constant-current potentiometry and spectrophotometry were used to follow the course of catalytic titrations of fluoride and silicofluoride with thorium nitrate. The hydrogen peroxide-iodide system was used as the indicator reaction. Titrations were performed in 50% ethanolic acetate buffer, pH 3.6. Amounts of 3.70 to 6.85 mg of ammonium fluoride, 5.53 to 10.79 mg of potassium fluoride and 4.34 to 8.41 mg of sodium silicofluoride were determined with a maximum average deviation of 0.9%. The results obtained are in good agreement with those of comparable methods. (author)

  11. Spectrophotometric determination of fluorides in water with Hach equipment

    International Nuclear Information System (INIS)

    The spectrophotometric method for the determination of the fluoride ion in water, demineralized water, raw waters, laundry waters and waters treated with ion exchange resins , using the technique and the SPADNS coloring indicated in the operation manual of the Hach equipment is described. This method covers the determination of the fluoride ion in the range from 0 to 2 mg/l on 25 ml. of radioactive base sample. These limits can be variable if the size of the used aliquot one is changed for the final determination of the fluoride ion. (Author)

  12. Nitrogen Trifluoride-Based Fluoride- Volatility Separations Process: Initial Studies

    Energy Technology Data Exchange (ETDEWEB)

    McNamara, Bruce K.; Scheele, Randall D.; Casella, Andrew M.; Kozelisky, Anne E.

    2011-09-28

    This document describes the results of our investigations on the potential use of nitrogen trifluoride as the fluorinating and oxidizing agent in fluoride volatility-based used nuclear fuel reprocessing. The conceptual process uses differences in reaction temperatures between nitrogen trifluoride and fuel constituents that produce volatile fluorides to achieve separations and recover valuable constituents. We provide results from our thermodynamic evaluations, thermo-analytical experiments, kinetic models, and provide a preliminary process flowsheet. The evaluations found that nitrogen trifluoride can effectively produce volatile fluorides at different temperatures dependent on the fuel constituent.

  13. Two dimensional condensation of argon adsorbed on lamellar halides

    International Nuclear Information System (INIS)

    Lamellar halides such as NiCl2, FeCl2, NiBr2, MnBr2, MgBr2, CdBr2, CoI2, FeI2, MnI2, CaI2 and PbI2 were sublimed in a rapid stream of dry nitrogen. The adsorption of argon on such materials shows stepped isotherms which reveal two dimensional condensations. From sets of isotherms the Helmholtz free energy, the internal energy and the entropy of the successive layers are determined. From the entropy of the first layer the role of the potential relief of the adsorbent surface on the structure of the adsorbed layer may be determined while the Helmholtz free energy reveals how the ionic character of the adsorbent governs the attractive force of adsorption. The study of the second third and fourth layers shows that their growth follows quite a different behaviour depending on whether the Van der Waals diameter of argon is greater or smaller than the distance between adjacent anions on the crystal surface. A proposition is made to account for the difference in the critical temperatures of the first and second dense layers in terms of the vibrationnal state of their respective substrate. The occurence for the maximum critical temperature observed of corresponding to a triangular layer 3% more expanded than the (111) plane of solid argon is discussed

  14. A liquid argon scintillation veto for the Gerda experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Bare germanium detectors are operated in a cryostat with 65 m{sup 3} of liquid argon (LAr). To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Q{sub ββ} at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  15. A liquid argon scintillation veto for the Gerda experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Bare germanium detectors are operated in a cryostat with 65 m3 of liquid argon (LAr). To reach the aspired background index of ≤10-3 cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Qββ at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  16. Demonstration and comparison of photomultiplier tubes at liquid Argon temperature

    International Nuclear Information System (INIS)

    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photomultiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics K.K. Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R and D program of the WArP Collaboration. During these tests the Hamamatsu PMTs showed excellent performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

  17. Electron density measurements of high pressure argon surface wave plasmas

    International Nuclear Information System (INIS)

    The electron density of an argon standing surface wave plasma has been measured from Stark broadening of the hydrogen H/sub beta/ (4861A) line. The experimental setup, consisting of two coaxial cavities, was similar to that reported by Rogers and Asmussen. The plasma was generated by 45 watts per cavity of CW, 2.54 GHz microwave power in a 6 mm O.D. (4 mm I.D.) quartz tube. Experimental argon gas pressure varied from 50 torr to over one atmosphere. Small amounts (1-5%) of hydrogen added to the argon plasma were found to shorten the plasma by as much as 80%. Thus, the Stark measurements were made using trace amounts of hydrogen. The line width of H/sub beta/ was measured with a 1 meter Czerny-Turner grating spectrometer. The Stark broadening measurements revealed that the electron density is between 1013 and 1014 electrons/cc for a pressure range of 50 to 1000 torr. These measurements agree very well with the electron density determined from the wavelength of standing surface waves. The volume of the plasma was also measured photographically and average plasma power densities (absorbed power in the plasma divided by the plasma volume) was calculated

  18. MARLEY: Model of Argon Reaction Low Energy Yields

    Science.gov (United States)

    Gardiner, Steven; Bilton, Kyle; Grant, Christopher; Pantic, Emilija; Svoboda, Robert

    2015-10-01

    Core-collapse supernovae are sources of tremendous numbers of neutrinos with energies of up to about 50 MeV. In recent years, there has been growing interest in building detectors that are sensitive to supernova neutrinos. Such detectors can provide information about the initial stages of stellar collapse, early warning signals for light emission from supernovae, and opportunities to study neutrino oscillation physics over astronomical distances. In an effort to enable supernova neutrino detection in next-generation experiments like DUNE, the CAPTAIN collaboration plans to make the first direct measurement of cross sections for neutrino interactions on argon in the supernova energy regime. To help predict neutrino event signatures in the CAPTAIN liquid argon time projection chamber (LArTPC), we have developed a first-of-its-kind Monte Carlo event generator called MARLEY (Model of Argon Reaction Low Energy Yields). This generator attempts to model the complicated nuclear structure dependence of low-energy neutrino-nucleus reactions in sufficient detail for use in LArTPC simulations. In this talk we present some preliminary results calculated using MARLEY and discuss how the current version of the generator may be improved and expanded.

  19. Isotopic fractionation of argon during stepwise release from shungite

    International Nuclear Information System (INIS)

    In previous attempts to determine the 40Ar/36Ar ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite, an amorphous carbon mineral The present work confirms a low value for 40Ar/36Ar in gas released from a type I shungite at low temperatures. But quantitative scrutiny of the accompanying 38AR/36Ar ratios and the enhanced ratio of 40Ar/36Ar for the fractions released at high temperatures shows convincingly that the effect seen here is an artifact of the stepwise heating and the argon diffusion mobilized thereby. The low 40Ar/36Ar previously obtained is very likely from the same cause rather than reflecting the isotopic composition of the pre-Cambrian atmosphere. The vitreous character of and the sharp, conchoidal fractures seen in the specimens of type I shungite suggest that the substance may exhibit simple volume diffusion over macroscopic dimensions as glasses do. If so, the diffusion parameters (D infinitely = 3 x 10-4 cm2/s and E = 11 kcal/mole) obtained from the data imply rapid exchange with the atmosphere for any argon initially trapped in centimenter-thick veins of the material. (orig.)

  20. Isotopic fractionation of argon during stepwise release from shungite

    Science.gov (United States)

    Rison, W.

    1980-05-01

    It is noted that in previous attempts to determine the Ar-40/Ar-36 ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite. In the present work, a low value for Ar-40/Ar-36 in gas released from a type I shungite at low temperatures is confirmed. Attention is given to a study of the accompanying Ar-38/Ar-36 ratios and the enhanced ratio of Ar-40/Ar-36 for the fractions released at high temperatures which shows that the effect observed is a result of the stepwise heating and the argon diffusion mobilized thereby. It is suggested that the low Ar-40/Ar-36 obtained in the past is from the same source rather than reflecting the isotropic composition of the pre-Cambrian atmosphere, and that the type I shungite may exhibit simple volume diffusion over macroscopic dimensions as glasses do. It is concluded that if this is so, the diffusion parameters obtained from the data would imply rapid exchange with the atmosphere for any argon initially trapped in the veins of the material.

  1. ARAPUCA a new device for liquid argon scintillation light detection

    International Nuclear Information System (INIS)

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R and D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors

  2. Demonstration and comparison of photomultiplier tubes at liquid Argon temperature

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Boffelli, F.; Cambiaghi, M.; Canci, N.; Cavanna, F.; Cocco, A. G.; Deniskina, N.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Grandi, L.; Kryczynski, P.; Meng, G.; Montanari, C.; Palamara, O.; Pandola, L.; Perfetto, F.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Triossi, A.; Ventura, S.; Vignoli, C.; Zani, A.

    2012-01-01

    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photomultiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics K.K. Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these tests the Hamamatsu PMTs showed excellent performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

  3. Metal clusters on supported argon layers; Metallcluster auf dielektrischen Substraten

    Energy Technology Data Exchange (ETDEWEB)

    Faber, Bernhard

    2011-10-21

    The deposition of small sodium clusters on supported Ar(001)-surfaces is simulated. Theoretical description is achieved by a hierarchical model consisting of time-dependent DFT and molecular dynamics. The valence electrons of the sodium atoms are considered by Kohn-Sham-Scheme with self interaction correction. The interaction of argon atoms and sodium ions is described by atom-atom potentials whereas the coupling to the QM electrons is done by local pseudo-potentials. A decisive part of the model is the dynamical polarizability of the rare-gas atoms. The optional metal support is considered by the method of image charges. The influence of the forces caused by image charges and the influence of the number of argon monolayers on structure, optical response and deposition dynamics of Na{sub 6} and Na{sub 8} is investigated. There is very little influence on cluster structure and only a small shift of the cluster perpendicular to the surface. Concerning optical response the position of the Mie plasmon peak stays robust whereas the details of spectral fragmentation react very sensitively to changes. The forces caused by image charges of the metal support play only a little role with the dynamics of deposition while the thickness of the argon surface strongly influences the dissipation. (orig.)

  4. Status of the ATLAS Liquid Argon Calorimeter and its Performance

    CERN Document Server

    Barillari, T; The ATLAS collaboration

    2011-01-01

    The ATLAS experiment is designed to study the proton-proton collisions produced at the LHC with a centre-of-mass energy of 14 TeV. Liquid argon (LAr) sampling calorimeters are used in ATLAS for all electromagnetic calorimetry covering the pseudorapidity region |eta|<3.2, as well as for hadronic calorimetry from |eta|=1.4 to |eta|=4.8. The calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic (EMEC), hadronic (HEC) and forward (FCAL) calorimeters. The lead-liquid argon sampling technique with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the endcap (EMEC). This geometry allows a uniform acceptance over the whole azimuthal range without any gap. The hadronic endcap calorimeter (HEC) uses a copper-liquid argon sampling technique with plate geometry and is subdivided into two wheels in depth per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules featuring cylindrical electrodes ...

  5. ARAPUCA a new device for liquid argon scintillation light detection

    Science.gov (United States)

    Machado, A. A.; Segreto, E.

    2016-02-01

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R&D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors.

  6. Graphene Fluoride: A Stable Stoichiometric Graphene Derivative and its Chemical Conversion to Graphene

    OpenAIRE

    Zbořil, Radek; Karlický, František; Bourlinos, Athanasios B.; Steriotis, Theodore A.; Athanasios K. Stubos; Georgakilas, Vasilios; Šafářová, Klára; Jančík, Dalibor; Trapalis, Christos; Otyepka, Michal

    2010-01-01

    Stoichoimetric graphene fluoride monolayers are obtained in a single step by the liquid-phase exfoliation of graphite fluoride with sulfolane. Comparative quantum-mechanical calculations reveal that graphene fluoride is the most thermodynamically stable of five studied hypothetical graphene derivatives; graphane, graphene fluoride, bromide, chloride, and iodide. The graphene fluoride is transformed into graphene via graphene iodide, a spontaneously decomposing intermediate. The calculated ban...

  7. Solubility of fluorides of alkaline earth metals and some rare earths in anhydrous trifluoroacetic acid

    International Nuclear Information System (INIS)

    Solubility of fluorides of alkaline earth and some rare earth metals in anhydrous trifluoroacetic acid is studied. For each type of fluoride solubility depends on the ionic radius of the cation. Solubility of fluorides of alkaline earth metals grows from magnesium to barium. All the fluorides in anhydrous trifluoroacetic acid form solvates. Solvates of strontium and scandium fluorides are shown to decompose at 110 and 150 deg C respectively

  8. Evaluation of efficacy caries prevent of stabilized fluoride dentifrices in students of medical university

    OpenAIRE

    Марченко, Наталья Сергеевна; Політун, Антоніна Михайлівна; Терешина, Тетяна Петрівна

    2015-01-01

    Conducted laboratory and clinical evaluation of the efficacy of  stabilized fluoride dentifrice compared to without fluoride dentifrice, for the prevention of dental caries in students. Indexes stability of fluoride in dentifrice containing fluoride , concentration and  prolonged action ionized fluoride in saliva for the prevention of dental caries.Methods: Clinical and laboratory testing of dentifrice in vivo and in vitro research.Results: In clinical and laboratory testing of caries prevent...

  9. Change in fluoride content of Maltese tapwaters : implications for oral health

    OpenAIRE

    Vella, Alfred J.; Borg, Vincent

    1989-01-01

    Dietary intake of fluoride is believed to be largely derived from drinking water. In Malta, tap water presently contains less fluoride than is found in naturally occurring ground water obtained from aquifers. Over 55% of water production comes from reverse osmosis and such water is practically fluoride-free. Before the introduction of reverse osmosis water into the water budget, fluoride levels measured from 10 different tap waters averaged 0.51 ppm F-. Now, fluoride content measured from 19 ...

  10. Determination of fluoride content in toothpaste using spectrophotometry

    Directory of Open Access Journals (Sweden)

    Susanti Pudji Hastuti

    2013-09-01

    Full Text Available Background: Intake excessive fluoride in children’s teeth are generally marked with white and brown patches. Excessive fluoride of more than 4.0 mg/L can cause a person suffering from poisoning, fragility of the bones (osteoporosis, liver and kidney damage. Knowledge about the spectrophotometry for determination method of fluoride content in commercially available toothpaste is very few. Purpose: The purposes of study were to examine the suitable method for fluoride extraction and to determine out the accuracy, precision, linearity, and stability of the measurement method of fluoride content in toothpaste. Methods: The suitable F extraction method was determined by the comparison among 3 methods of extraction; e.g. the dried samples were immersed in (1 distilled water, (2 96% HCl, and (3 96% HNO3; and the validation methods of measurement were the maximum wavelength, standart curve, accuracy test, precision test, and stability test. Results: Result showed that the fluoride extraction by using the concentrated HNO3 was found to have the highest levels of fluoride, followed by hydrochloric acid dissolution (HCl and distilled water, while the method of validation showed that SPADNS revealed the acceptable accuracy. Precision has the RSD ≤ 2.00%. Furthermore the stability test result showed that the measurement of fluoride less than 2 hours was still reliable. Conclusion: The study suggested that the best result of fluoride extraction from toothpaste could be gained by using concentrate HNO3, and the spectrophotometer (UV-Vis Mini Shimadzu U-1240 and SPADNS have the acceptable accuracy.Latar Belakang: Pemasukan fluoride yang berlebihan pada gigi anak ditandai dengan bercak putih dan coklat. Fluoride lebih dari 4.0 mg / L dapat menyebabkan seseorang menderita keracunan , kerapuhan tulang (osteoporosis, kerusakan hati dan ginjal. Pengetahuan tentang spektrofotometri untuk metode penentuan kadar fluoride dalam pasta gigi yang tersedia secara

  11. Cerium fluoride crystals for calorimetry at LHC

    International Nuclear Information System (INIS)

    High-resolution homogeneous calorimetry is fully justified for part of the physics program at the Large Hadron Collider (LHC). The main design features of proposed CeF3 crystals for calorimetry for LHC are discussed. The severe constraints LHC imposes on detectors make the use of 'classical' crystals impossible. Therefore, a large R and D effort has been undertaken by the 'Crystal Clear' collaboration in order to find new, dense, fast and radiation hard crystals. A good candidate, cerium fluoride, has been identified and studied. It is interesting at this stage to review the specifications of scintillators for LHC and to see how well available data on CeF3 luminescence, decay time, light yield, optical transmission and resistance to radiation meet them. Milestones to reach before starting a large scale crystal production in view of the eventual construction of a calorimeter, are also discussed. (author) 15 refs., 15 figs., 1 tab

  12. Further results on cerium fluoride crystals

    International Nuclear Information System (INIS)

    A systematic investigation of the properties of cerium fluoride monocrystals has been performed by the 'Crystal Clear' collaboration in view of a possible use of such crystals for the construction of high precision electromagnetic calorimeters for the future generation of high luminosity accelerators. A large sample of different crystals grown by several producers has been studied. The spectroscopic characteristics, the transmission, luminescence and excitation spectra and the decay time curves are analysed. The light yield of the different crystals is measured with photomultipliers and Si photodiodes and compared to reference standards like BGO and NaI(Tl). The radiation damage behaviour is then presented for γ and neutron irradiations, at different doses and dose rates, including thermal and optical bleaching. (orig.)

  13. Further results on cerium fluoride crystals

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.; Auffray, E.; Aziz, T.; Baccaro, S.; Banerjee, S.; Bareyre, P.; Barone, L.E.; Borgia, B.; Boutet, D.; Burq, J.P.; Chemarin, M.; Chipaux, R.; Dafinei, I.; D' Atanasio, P.; De Notaristefani, F.; Dezillie, B.; Dujardin, C.; Dutta, S.; Faure, J.L.; Fay, J.; Ferrere, D.; Francescangeli, O.; Fuchs, B.A.; Ganguli, S.N.; Gillespie, G.; Goyot, M.; Gupta, S.K.; Gurtu, A.; Heck, J.; Herve, A.; Hillemanns, H.; Holdener, F.; Ille, B.; Joensson, L.; Kierstead, J.; Krenz, W.; Kway, W.; Le Goff, J.M.; Lebeau, M.; Lebrun, P.; Lecoq, P.; Lemoigne, Y.; Loomis, G.; Lubelsmeyer, K.; Madjar, N.; Majni, G.; El Mamouni, H.; Mangla, S.; Mares, J.A.; Martin, J.P.; Mattioli, M.; Mauger, G.J.; Mazumdar, K.; Mengucci, P.; Merlo, J.P.; Moine, B.; Nikl, N.; Pansart, J.P.; Pedrini, C.; Poinsignon, J.; Polak, K.; Raghavan, R.; Rebourgeard, P.; Rinaldi, D.; Rosa, J.; Rosowsky, A.; Sahuc, P.; Samsonov, V.; Sarkar, S.; Schegelski, V.; Schmitz, D.; Schneegans, M.; Seliverstov, D.; Stoll, S.; Sudhakar, K.; Sven; Crystal Clear Collaboration

    1993-08-15

    A systematic investigation of the properties of cerium fluoride monocrystals has been performed by the 'Crystal Clear' collaboration in view of a possible use of such crystals for the construction of high precision electromagnetic calorimeters for the future generation of high luminosity accelerators. A large sample of different crystals grown by several producers has been studied. The spectroscopic characteristics, the transmission, luminescence and excitation spectra and the decay time curves are analysed. The light yield of the different crystals is measured with photomultipliers and Si photodiodes and compared to reference standards like BGO and NaI(Tl). The radiation damage behaviour is then presented for [gamma] and neutron irradiations, at different doses and dose rates, including thermal and optical bleaching. (orig.)

  14. Chemical etching of polyvinylidene fluoride films

    International Nuclear Information System (INIS)

    The chemical etching of two types of polyvinylidene fluoride (PVDF) film irradiated with heavy ions was studied. Several etchants have been investigated in this work. It was found that for a solution of KOH+KMnO4 the radial etch rate (RER) is larger than for solutions used by other authors. This new solution for etching PVDF is used both for microfilter and for track detector purposes. Even alphas from a thick uranium foil register in solef PVDF by using this solution. As expected the RER for alphas is considerably lower than that for heavy ions. The diameter of the sandglass shaped pores at the surface of the film as a function of the etching time for various concentrations of KMnO4 and KOH and at different temperatures was measured. (author)

  15. Fluoridated toothpaste: usage and ingestion of fluoride by 4- to 6-yr-old children in England.

    Science.gov (United States)

    Zohoori, Fatemeh V; Duckworth, Ralph M; Omid, Narges; O'Hare, William T; Maguire, Anne

    2012-10-01

    Fluoridated toothpaste is effective for dental caries control, yet may be a risk factor for dental fluorosis. This study aimed to quantify fluoride ingestion from toothpaste by children and to investigate the effects of age, gender, and social class on the amount of fluoride ingested per toothbrushing session. Sixty-one children, 4-6 yr of age, were recruited: 38 were from low socio-economic (LSE) areas of Newcastle, UK, and 23 were from high socio-economic (HSE) areas of Newcastle, UK. All expectorated saliva, rinse water (if used), and residual toothpaste were collected after brushing at home and were analysed for fluoride. Of the children, 74% and 69% from HSE and LSE areas, respectively, claimed that they brushed twice per day. The mean (SD) weight of toothpaste dispensed was 0.67 (0.36) g. The mean (SD) amount of fluoride ingested per toothbrushing session and per day was 17.0 (14.7) and 29.3 (32.8) μg kg(-1) of body weight, respectively. Daily fluoride intake per kilogram of body weight did not differ significantly between children from LSE and HSE areas. Fluoride intake per toothbrushing session was significantly influenced by weight of toothpaste, its fluoride concentration, and the child's age. Whilst the average amount of toothpaste used per toothbrushing session was more than twice the recommended amount (of 0.25 g), only one child had a daily fluoride intake that exceeded the tolerable upper intake level of 0.1 mg kg(-1) of body weight for this age group. PMID:22984999

  16. Using High Fluoride Concentration Products in Public Policy: A Rapid Review of Current Guidelines for High Fluoride Concentration Products.

    Science.gov (United States)

    Douglas, Gail V A; Ramsdale, Martin P; Vinall-Collier, Karen; Csikar, Julia I

    2016-01-01

    Despite improvements in dental caries levels since the widespread introduction of fluoride toothpastes, it is still a disease which is considered to be a priority in many countries around the world. Individuals at higher risk of caries can be targeted with products with a high fluoride concentration to help reduce the amount and severity of the disease. This paper compares guidance from around the world on the use of products with a high fluoride concentration and gives examples of how guidance has been translated into activity in primary care dental practice. A rapid review of electronic databases was conducted to identify the volume and variation of guidance from national or professional bodies on the use of products with a high fluoride concentration. Fifteen guidelines published within the past 10 years and in English were identified and compared. The majority of these guidelines included recommendations for fluoride varnish use as well as for fluoride gels, while a smaller number offered guidance on high fluoride strength toothpaste and other vehicles. Whilst there was good consistency in recommendations for fluoride varnish in particular, there was sometimes a lack of detail in other areas of recommendation for other vehicles with a high fluoride concentration. There are good examples within the UK, such as the Childsmile project and Delivering Better Oral Health, which highlight that the provision of evidence-based guidance can be influential in directing scarce resources towards oral health improvements. Policy can be influenced by evidence-based national recommendations and used to help encourage dental professionals and commissioners and third-party payers to adopt higher levels of practices aimed at oral health improvement. PMID:27100106

  17. Roles of argon seeding in energy confinement and pedestal structure in JT-60U

    International Nuclear Information System (INIS)

    The mechanism of improving energy confinement with argon seeding at high density has been investigated in JT-60U. Better confinement is sustained at high density by argon seeding accompanied by higher core and pedestal temperatures. The electron density profiles become flatter with increasing density in conventional H-mode plasmas, whereas peaked density profiles are maintained with argon seeding. Density peaking and dilution effects lower the pedestal density at a given averaged density. The pedestal density in the argon seeded plasmas, which is lower than that in plasmas with deuterium puff, enables the pedestal temperature to be higher, whereas the increase in the pedestal pressure with argon seeding is small. High pedestal temperature is a boundary condition for high core temperature through profile stiffness, which leads to better confinement with argon seeding. The density peaking is a key factor of sustaining better confinement in argon seeded H-mode plasmas. The radiative loss power density is predominantly enhanced in the edge region by argon puff. The role of argon seeding in the pedestal characteristics has also been examined. The pedestal width becomes larger continuously with edge collisionality, but is nearly independent of the presence of argon seeding. (paper)

  18. Argon-41 production and evolution at the Oregon State University TRIGA Reactor (OSTR)

    International Nuclear Information System (INIS)

    In this study, argon-41 concentrations were measured at various locations within the reactor facility to assess the accuracy of models used to predict argon-41 evolution from the reactor tank, and to determine the relationship between argon gas evolution from the tank and subsequent argon-41 concentrations throughout the reactor room. In particular, argon-41 was measured directly above the reactor tank with the reactor tank lids closed, at other accessible locations on the reactor top with the tank lids both closed and open, and at several locations on the first floor of the reactor room. These measured concentrations were then compared to values calculated using a modified argon-41 production and evolution model for TRIGA reactor tanks and ventilation values applicable to the OSTR facility. The modified model was based in part on earlier TRIGA models for argon-41 production and release, but added features which improved the agreement between predicted and measured values. The approximate dose equivalent rate due to the presence of argon-41 in reactor room air was calculated for several different locations inside the OSTR facility. These dose rates were determined using the argon-41 concentration measured at each specific location, and were subsequently converted to a predicted quarterly dose equivalent for each location based on the reactor's operating history. The predicted quarterly dose equivalent values were then compared to quarterly doses measured by film badges deployed as dose-integrating area radiation monitors at the locations of interest. The results indicate that the modified production and evolution model is able to predict argon-41 concentrations to within a factor of ten when compared to the measured data. Quarterly dose equivalents calculated from the measured argon-41 concentrations and the reactor's operating history seemed consistent with results obtained from the integrating area radiation monitors. Given the argon-41 concentrations measured

  19. Preparation and Characterization of Rare Earth Doped Fluoride Nanoparticles

    Directory of Open Access Journals (Sweden)

    Timothy A. DeVol

    2010-03-01

    Full Text Available This paper reviews the synthesis, structure and applications of metal fluoride nanoparticles, with particular focus on rare earth (RE doped fluoride nanoparticles obtained by our research group. Nanoparticles were produced by precipitation methods using the ligand ammonium di-n-octadecyldithiophosphate (ADDP that allows the growth of shells around a core particle while simultaneously avoiding particle aggregation. Nanoparticles were characterized on their structure, morphology, and luminescent properties. We discuss the synthesis, properties, and application of heavy metal fluorides; specifically LaF3:RE and PbF2, and group IIA fluorides. Particular attention is given to the synthesis of core/shell nanoparticles, including selectively RE-doped LaF3/LaF3, and CaF2/CaF2 core/(multi-shell nanoparticles, and the CaF2-LaF3 system.

  20. Redox condition in molten fluoride salts Definition and control

    International Nuclear Information System (INIS)

    The loosely-used term 'redox condition' as applied to molten fluoride salts such as flibe is defined quantitatively as the fluorine potential. Several methods of controlling the property of the melt are discussed

  1. Physical and chemical properties of volatile ruthenium fluorides

    International Nuclear Information System (INIS)

    Available data are compiled published before 1977 on the preparation and the physical and chemical properties of ruthenium hexafluoride, ruthenium oxide tetrafluoride, ruthenium pentafluoride and ruthenium octa-fluoride. (author)

  2. Efficacy of silver diamine fluoride as an antibacterial as well as antiplaque agent compared to fluoride varnish and acidulated phosphate fluoride gel: An in vivo study

    Directory of Open Access Journals (Sweden)

    Shalin Shah

    2013-01-01

    Full Text Available Background: Silver diamine fluoride (SDF is already proven as an antibacterial agent in vitro. Present study was formulated to compare the efficacy of SDF as an antibacterial as well as antiplaque agent in vivo with fluoride varnish and acidulated phosphate fluoride (APF gel. Study Design: Total 123 children (male = 82, female = 41 were included in the study for a period of 18 months. Children were divided into three different groups-Group 1: SDF; Group 2: fluoride varnish; and Group 3: APF gel. All subjects were evaluated via plaque score at 6 th , 12 th , and 18 th months as well as Streptococcus mutans counts in saliva at 72 h, 6 th , 12 th , and 18 th months of follow-up. Results: Significant reduction was found in plaque score as well as S. mutans counts irrespective of group division. On intergroup comparison, no statistically significant difference was found in plaque score, but significant reduction in S. mutans counts was found in Group 1 as compared with Groups 2 and 3, while no significant difference was found between Groups 2 and 3. Conclusion: In vivo application of SDF on enamel significantly decreases S. mutans counts as compared to fluoride varnish and APF gel.

  3. Preparation and Characterization of Rare Earth Doped Fluoride Nanoparticles

    OpenAIRE

    DeVol, Timothy A.; Basak Yazgan-Kukouz; Baris Kokuoz; DiMaio, Jeffrey R.; Kevin B. Sprinkle; James, Tiffany L.; Kucera, Courtney J.; Jacobsohn, Luiz G.; John Ballato

    2010-01-01

    This paper reviews the synthesis, structure and applications of metal fluoride nanoparticles, with particular focus on rare earth (RE) doped fluoride nanoparticles obtained by our research group. Nanoparticles were produced by precipitation methods using the ligand ammonium di-n-octadecyldithiophosphate (ADDP) that allows the growth of shells around a core particle while simultaneously avoiding particle aggregation. Nanoparticles were characterized on their structure, morphology, and luminesc...

  4. Corrosion behavior of zirconia in acidulated phosphate fluoride

    OpenAIRE

    Anie Thomas; Sathyanarayanan Sridhar; Shant Aghyarian; Pilanda Watkins-curry; Chan, Julia Y.; Alessandro Pozzi; Danieli C. Rodrigues

    2016-01-01

    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all specimens were imaged using digital microscopy and scanning electron microscopy (SEM). Sample mass and dimensions were measured for mass loss determination. Samples were charac...

  5. Corrosion behavior of zirconia in acidulated phosphate fluoride

    OpenAIRE

    Thomas, Anie; Sridhar, Sathyanarayanan; Aghyarian, Shant; Watkins-Curry, Pilanda; Chan, Julia Y.; Pozzi, Alessandro; Danieli C. Rodrigues

    2016-01-01

    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all specimens were imaged using digital microscopy and scanning electron microscopy (SEM). Sample mass and dimensions were measured for mass loss determination. Samples were characteri...

  6. Fluoride Consumption and Its Impact on Oral Health

    OpenAIRE

    Luis Fernando Jacinto-Alemán; Javier de la Fuente-Hernández; María Dolores Jiménez-Farfán; Juan Carlos Hernández-Guerrero; Lilia Adriana Juárez-López

    2011-01-01

    Objective. The purpose of this study was to evaluate caries and dental fluorosis among Mexican preschoolers and school-aged children in a non-endemic zone for fluorosis and to measure its biological indicators. Methods. DMFT, DMFS, dmft, dmfs, and CDI indexes were applied. Fluoride urinary excretion and fluoride concentrations in home water, table salt, bottled water, bottled drinks, and toothpaste were determined. Results. Schoolchildren presented fluorosis (CDI = 0.96) and dental caries (DM...

  7. Scientific Opinion on Dietary Reference Values for fluoride

    OpenAIRE

    EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA)

    2013-01-01

    Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA) derived Dietary Reference Values (DRVs) for fluoride, which are provided as Adequate Intake (AI) from all sources, including non-dietary sources. Fluoride is not an essential nutrient. Therefore, no Average Requirement for the performance of essential physiological functions can be defined. Nevertheless, the Panel considered that the setting of an AI is appropriate because of the be...

  8. Thermodynamic investigation of fluoride salts for nuclear energy production

    OpenAIRE

    Beilmann, Markus

    2013-01-01

    In this work thermodynamic properties of molten fluoride salts and salt mixtures are investigated. Fluoride salts have advantageous properties to be used in energy producing systems based on the conversion from heat to energy like i.e in Molten Salt Reactors. For this purpose it is very important to have detailed information about the heat capacity of the pure salts and salt mixtures. To get a better understanding about the heat capacity in mixtures drop calorimetry measurements of mixture...

  9. The economic value of Quebec’s water fluoridation program

    OpenAIRE

    Tchouaket, Eric; Brousselle, Astrid; Fansi, Alvine; Dionne, Pierre Alexandre; Bertrand, Elise; Fortin, Christian

    2013-01-01

    Aim Dental caries is a major public health problem worldwide, with very significant deleterious consequences for many people. The available data are alarming in Canada and the province of Quebec. The water fluoridation program has been shown to be the most effective means of preventing caries and reducing oral health inequalities. This article analyzes the cost-effectiveness of Quebec’s water fluoridation program to provide decision-makers with economic information for assessing its usefulnes...

  10. Polyvinylidene fluoride based nanocomposites for the development of energy systems

    OpenAIRE

    Pereira, J. Nunes

    2013-01-01

    The economic and environmental costs of current energy resources created the need to develop new methods to generate and store energy. In this sense, the development of polymer materials led to the emergence of a new generation of porous polymers for energy applications, which are typically described as “energy polymers”. The specific properties of poly(vinylidene fluoride) (PVDF) and its copolymer poly(vinylidene fluoride-co-trifluoroethylene) (P(VDF-TrFE)), such as high diele...

  11. Quality of our groundwater resources: arsenic and fluoride

    Science.gov (United States)

    Nordstrom, D. Kirk

    2011-01-01

    Groundwater often contains arsenic or fluoride concentrations too high for drinking or cooking. These constituents, often naturally occurring, are not easy to remove. The right combination of natural or manmade conditions can lead to elevated arsenic or fluoride which includes continental source rocks, high alkalinity and pH, reducing conditions for arsenic, high phosphate, high temperature and high silica. Agencies responsible for safe drinking water should be aware of these conditions, be prepared to monitor, and treat if necessary.

  12. Polyacrylamide supported SPADNS-zirconium resin for fluoride removal

    International Nuclear Information System (INIS)

    Fluoride contamination of groundwater, both anthropogenic and natural, is a major problem worldwide. In the present work a new adsorbent has been prepared by incorporating SPADNS (trisodium 2-parasulfophenylazo-1,8-dihydroxy-3,6-napthalenedisulfonate salt) into the acrylamide matrix. SPADNS was selected because it has strong complexating ability towards zirconium. The substrate was conditioned for selective fluoride ion sorption by forming zirconium complex with SPADNS. The adsorbent was characterized using FTlR and EDXRF analysis

  13. Electrochemistry of silicon in chloro-fluoride and carbonate melts

    Directory of Open Access Journals (Sweden)

    Devyatkin S.V.

    2003-01-01

    Full Text Available The electrochemical behavior of K2SiF6 in chloro-fluoride melts and that of SiO2 in carbonate melts has been studied. Silicon, titanium silicides, boron silicide and ternary compounds Ti-Si-B have been deposited from chloro-fluoride melts. Only SiC was deposited from carbonate-silica melts under carbon dioxide atmosphere (that is, excessive pressure of CO2.

  14. Fluoride-assisted synthesis of bimodal microporous SSZ-13 zeolite.

    Science.gov (United States)

    Zhu, Xiaochun; Kosinov, Nikolay; Hofmann, Jan P; Mezari, Brahim; Qian, Qingyun; Rohling, Roderigh; Weckhuysen, Bert M; Ruiz-Martínez, Javier; Hensen, Emiel J M

    2016-02-21

    The presence of small amount of fluoride in alkaline hydrothermal synthesis of SSZ-13 zeolite yields bimodal microporous particles with substantially improved performance in the methanol-to-olefins (MTO) reaction. Hydrocarbon uptake measurements and fluorescence microspectroscopy of spent catalysts demonstrate enhanced diffusion through micropores at the grain boundaries of nanocrystals running through the zeolite particles. Fluoride-assisted SSZ-13 synthesis is a cheap and scalable approach to optimize the performance of MTO zeolite catalysts. PMID:26810114

  15. Fluoride levels in commercial dentifrices and drinking Water in Algeria

    OpenAIRE

    MERGHACHE, D.; BELLOUT, B.; MERGHACHE, S.; BOUCHERIT-ATMANI, Z.

    2011-01-01

    More and more scientific evidence show that fluorides have a cariostatic action to the plaque-saliva-tooth interface during cariogenous dissolution. Fluorides slow down demineralization and enhance remineralization. Their action is optimal, in the oral environment, when used at low concentrations on a continuous basis. The use of the fluorinated toothpastes during brushing of the teeth is a simple, rational method of daily topics application of fluorine, largely used in the context of prevent...

  16. Fluoride Concentration in Drinking Water Resources; North of Iran

    Directory of Open Access Journals (Sweden)

    Amouei A.I. PhD,

    2016-03-01

    Full Text Available Aims Fluoride is one of the anions present in soil and water, and determining its level in drinking water is vital for preventing dental and bone diseases in societies. This research aimed to determine fluoride concentrations in drinking water sources of rural and urban areas of Babol City, Iran. Instrument & Methods This descriptive cross-sectional study was conducted in Babol City, Iran, in 2014. 384 water samples were taken from 43 wells and 3 springs in the rural areas, and from 20 wells, 3 water reservoirs, and the water distribution system in the urban areas. Fluoride concentrations of water samples were measured with a model DR2000 spectrophotometer using the standard SPADNS method. Data were entered to SPSS 16 software and were analyzed by ANOVA test. Findings The mean fluoride concentrations in the water samples of the deep wells were higher compared to those of the springs (p=0.01. The mean fluoride concentrations in the plains areas were higher compared to the mountainous regions (p=0.02. The mean fluoride concentrations in the wells of the urban areas, in the urban reservoirs, and in the urban water distribution system were 0.40±0.14, 0.39±0.15, and 0.40±0.15mg/l, respectively (p=0.07. Fluoride concentrations in water in urban areas during various seasons varied from 0.31 to 0.45mg/l (p=0.06. Conclusion Fluoride concentrations in all drinking water sources in urban and rural areas of Babol are less than the ranges recommended by WHO and Iranian national standards.

  17. EXPERIMENTAL STUDY AND NUMERICAL SIMULATION OF FLUORIDE IN SAND

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong-mei; SU Bao-yu

    2006-01-01

    The transport and transformation of fluoride in sand were studied by using soil tank test under the condition of saturated water in this article. Based on the analysis of the laboratory experiments, the rules of fluorine transportation and transformation were simulated in sand by solving the advection-diffusion equation. Through comparison between computed results and observed data , it is shown that the established model and determined parameters could be used to simulate the fluoride transport in sand.

  18. Fluoride, aluminum, and phosphate kinetics in cryolite workers.

    Science.gov (United States)

    Grandjean, P; Hørder, M; Thomassen, Y

    1990-01-01

    Exposure to cryolite (Na3AlF6) dust may result in skeletal fluorosis. Eight male workers at a cryolite concentrator participated in a 4-day study after 5 days of vacation. Dust exposures were 0.16 to 21.2 mg/m3. Urine was collected before work began and during two 4-hour periods. Preshift urine fluoride concentrations increased during the week. Fluoride concentrations in postshift urine and serum both correlated with the dust exposures. Serum fluoride concentrations decreased with a half-life of 3.3 to 6.9 hours after work. Fluoride clearance was 40.5 to 76.5 mL/min at urinary flow rates of 0.89 to 2.21 mL/min. Serum aluminum concentrations varied without relation to the exposure, but the urinary aluminum excretion correlated with the fluoride levels. Preshift serum-phosphate concentrations increased significantly during the week, possibly indicating changes in mineral metabolism. For monitoring of individual uptake of cryolite dust, serum fluoride measurements are most useful. PMID:2324845

  19. Fluoride and aluminum in teas and tea-based beverages

    Directory of Open Access Journals (Sweden)

    Hayacibara Mitsue Fujimaki

    2004-01-01

    Full Text Available OBJECTIVE: To evaluate fluoride and aluminum concentration in herbal, black, ready-to-drink, and imported teas available in Brazil considering the risks fluoride and aluminum pose to oral and general health, respectively. METHODS: One-hundred and seventy-seven samples of herbal and black tea, 11 types of imported tea and 21 samples of ready-to-drink tea were divided into four groups: I-herbal tea; II-Brazilian black tea (Camellia sinensis; III-imported tea (Camellia sinensis; IV-ready-to-drink tea-based beverages. Fluoride and aluminum were analyzed using ion-selective electrode and atomic absorption, respectively. RESULTS: Fluoride and aluminum levels in herbal teas were very low, but high amounts were found in black and ready-to-drink teas. Aluminum found in all samples analyzed can be considered safe to general health. However, considering 0.07 mg F/kg/day as the upper limit of fluoride intake with regard to undesirable dental fluorosis, some teas exceed the daily intake limit for children. CONCLUSIONS: Brazilian and imported teas made from Camellia sinensis as well as some tea-based beverages are sources of significant amounts of fluoride, and their intake may increase the risk of developing dental fluorosis.

  20. Preparation of mixed rare earths modified chitosan for fluoride adsorption

    Institute of Scientific and Technical Information of China (English)

    梁鹏; 张艺; 汪东风; 徐莹; 罗斓

    2013-01-01

    This paper described the fluoride removal from water using a new adsorbent namely mixed rare earths modified chitosan (CR). Mixed rare earths mainly contained La followed by Ce which was analyzed by inductively coupled plasma mass spectrometry (ICP-MS). La(III)-modified chitosan (CL) was also prepared as control. For the batch technique, the effects of various parameters such as contact time, pH, adsorbent dose, initial fluoride concentration and co-ions on fluoride adsorption were studied. Fourier trans-form infrared spectroscopy (FTIR) and X-ray diffraction (XRD) were used to characterize adsorbents. It was observed that the fluo-ride adsorption capacity of CR (3.72 mgF-/g) was higher than CL (3.16 mgF-/g) at 2 h. The presence of co-ions such as bicarbonate and carbonate greatly affected the fluoride adsorption from water. Characterization experiments indicated the successful chelation between mixed rare earths and chitosan. The possible fluoride adsorption mechanism of CR was explained by a chemical reaction.

  1. Monitoring of fluoride in water samples using a smartphone.

    Science.gov (United States)

    Levin, Saurabh; Krishnan, Sunderrajan; Rajkumar, Samuel; Halery, Nischal; Balkunde, Pradeep

    2016-05-01

    In several parts of India, groundwater is the only reliable, year round source for drinking water. Prevention of fluorosis, a chronic disease resulting from excess intake of fluoride, requires the screening of all groundwater sources for fluoride in endemic areas. In this paper, the authors present a field deployable colorimetric analyzer based on an inexpensive smartphone embedded with digital camera for taking photograph of the colored solution as well as an easy-fit, and compact sample chamber (Akvo Caddisfly). Phones marketed by different smartphone makers were used. Commercially available zirconium xylenol orange reagent was used for determining fluoride concentration. A software program was developed to use with the phone for recording and analyzing the RGB color of the picture. Linear range for fluoride estimation was 0-2mgl(-1). Around 200 samples, which consisted of laboratory prepared as well as field samples collected from different locations in Karnataka, India, were tested with Akvo Caddisfly. The results showed a significant positive correlation between Ion Selective Electrode (ISE) method and Akvo Caddisfly (Phones A, B and C), with correlation coefficient ranging between 0.9952 and 1.000. In addition, there was no significant difference in the mean fluoride content values between ISE and Phone B and C except for Phone A. Thus the smartphone method is economical and suited for groundwater fluoride analysis in the field. PMID:26874766

  2. Removal of fluoride from water using aluminium containing compounds

    Institute of Scientific and Technical Information of China (English)

    M. Karthikeyan; K. P. Elango

    2009-01-01

    Batch adsorption studies were undertaken to assess the suitability of aluminium titanate (AT) and bismuth aluminate (BA) to remove fluoride ions from water.The effect of pH,dose of adsorbent,contact time,initial concentration,co-ions and temperature on fluoride removal efficiency were studied.The amounts of fluoride ions adsorbed,at 30℃ from 4 mg/L of fluoride ion solution,by AT and BA are 0.85 and 1.55 mg/g,respectively.The experimental data fitted well to the Freundlich and Langmuir isotherms.Thermodynamic parameters such as △H~0,△S~0 and △G~0 indicated that the removal of fluoride ions by AT is exothermic and non-spontaneous while that by BA is endothermic and spontaneous.Furrier transform infrared (FT-IR) analysis and X-ray diffraction (XRD) patterns of the adsorbent before and after adsorption indicated that fluoride ions are chemisorbed by these adsorbents.

  3. Water Fluoridation: A Critical Review of the Physiological Effects of Ingested Fluoride as a Public Health Intervention

    OpenAIRE

    Stephen Peckham; Niyi Awofeso

    2014-01-01

    Fluorine is the world's 13th most abundant element and constitutes 0.08% of the Earth crust. It has the highest electronegativity of all elements. Fluoride is widely distributed in the environment, occurring in the air, soils, rocks, and water. Although fluoride is used industrially in a fluorine compound, the manufacture of ceramics, pesticides, aerosol propellants, refrigerants, glassware, and Teflon cookware, it is a generally unwanted byproduct of aluminium, fertilizer, and iron ore manuf...

  4. Using High Fluoride Concentration Products in Public Policy – A Rapid Review of Current Guidelines for High Fluoride Concentration products

    OpenAIRE

    Douglas, GVA; Ramsdale, M; Vinall, K.; Csikar, J

    2016-01-01

    Despite improvements in caries levels since widespread introduction of fluoride toothpastes it remains a priority in many countries around the world. Higher caries risk individuals can be targeted with products with a high fluoride concentration to help reduce the amount and severity of disease. This paper compares guidance from around the world on the use of such products and gives examples of how guidance has been translated into activity in primary care dental practice. A rapid review of e...

  5. High Temperature Fluoride Salt Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Richard Burns [Univ. of Tennessee, Knoxville, TN (United States); Fugate, David L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Holcomb, David Eugene [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Peretz, Fred J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Robb, Kevin R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Dane F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Yoder, Jr, Graydon L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-12-01

    Effective high-temperature thermal energy exchange and delivery at temperatures over 600°C has the potential of significant impact by reducing both the capital and operating cost of energy conversion and transport systems. It is one of the key technologies necessary for efficient hydrogen production and could potentially enhance efficiencies of high-temperature solar systems. Today, there are no standard commercially available high-performance heat transfer fluids above 600°C. High pressures associated with water and gaseous coolants (such as helium) at elevated temperatures impose limiting design conditions for the materials in most energy systems. Liquid salts offer high-temperature capabilities at low vapor pressures, good heat transport properties, and reasonable costs and are therefore leading candidate fluids for next-generation energy production. Liquid-fluoride-salt-cooled, graphite-moderated reactors, referred to as Fluoride Salt Reactors (FHRs), are specifically designed to exploit the excellent heat transfer properties of liquid fluoride salts while maximizing their thermal efficiency and minimizing cost. The FHR s outstanding heat transfer properties, combined with its fully passive safety, make this reactor the most technologically desirable nuclear power reactor class for next-generation energy production. Multiple FHR designs are presently being considered. These range from the Pebble Bed Advanced High Temperature Reactor (PB-AHTR) [1] design originally developed by UC-Berkeley to the Small Advanced High-Temperature Reactor (SmAHTR) and the large scale FHR both being developed at ORNL [2]. The value of high-temperature, molten-salt-cooled reactors is also recognized internationally, and Czechoslovakia, France, India, and China all have salt-cooled reactor development under way. The liquid salt experiment presently being developed uses the PB-AHTR as its focus. One core design of the PB-AHTR features multiple 20 cm diameter, 3.2 m long fuel channels

  6. Comparative effects of argon green and krypton red laser photocoagulation for patients with diabetic exudative maculopathy.

    OpenAIRE

    Khairallah, M; Brahim, R; Allagui, M.; Chachia, N

    1996-01-01

    AIMS/BACKGROUND: Focal treatment of diabetic macular oedema is usually done using a haemoglobin absorbing wave-length, such as argon green laser. This study aimed to compare photocoagulation with argon green (514 nm) and krypton red (647 nm), which is poorly absorbed by haemoglobin, in the focal treatment of patients with diabetic exudative maculopathy. METHODS: A total of 151 eyes of 78 outpatients were assigned randomly to receive either argon green (n = 79) or krypton red (n = 72) laser tr...

  7. Emission properties of an atmospheric pressure argon plasma jet excited by barrier discharge

    International Nuclear Information System (INIS)

    An atmospheric-pressure argon plasma jet is initiated by the barrier discharge in a capillary, through which argon was flown. The spectral composition of radiation emitted by the jet in the atmosphere and its variation in the space are analyzed in detail. The jet radiation spectrum is shown to be predominantly formed by spectral transitions of argon and oxygen atoms, by electron-vibrational transitions of the first positive system of nitrogen molecules N2, and by transitions of hydroxyl radical OH

  8. The effects of argon in the bioenergetics of the hamster and the rat

    Science.gov (United States)

    Tempel, G. E.; Musacchia, X. J.

    1974-01-01

    Oxygen consumption was examined in hamsters and rats exposed to normoxic mixtures of argon at 1 atm. In fasted and nonfasted animals, no marked change in O2 utilization was detectable at 22 C. However, at 7 C a significant decrease in oxygen consumption was observed where the animals were exposed in argon. The data are interpreted in terms of the greater thermal conductivity of nitrogen. The study was prompted by conflicting reports on the metabolic effects of argon and helium.

  9. Phytotoxicity of sodium fluoride and uptake of fluoride in willow trees.

    Science.gov (United States)

    Clausen, Lauge Peter Westergaard; Karlson, Ulrich Gosewinkel; Trapp, Stefan

    2015-01-01

    The willow tree (Salix viminalis) toxicity test and a cress seed germination test (Lepidium sativum) were used to determine uptake of F and phytotoxicity of NaF. Concentrations in hydroponic solutions were 0-1000 mg F/L and 0-400 mg F/L in the preliminary and definitive test. A third test was done with soils collected from a fluoride-contaminated site at Fredericia, Denmark. The EC10, EC20 and EC50-values for inhibition of transpiration were determined to 38.0, 59.6 and 128.7 mg F/L, respectively. The toxicity test with soil showed strong inhibition for the sample with the highest fluoride concentration (405 mg free F per kg soil, 75 mg F per L soil solution). The seed germination and root elongation test with cress gave EC10, EC20 and EC50-values of 61.4, 105.0 and 262.8 mg F/L, respectively. At low external concentrations, fluoride was taken up more slowly than water and at high external concentrations at the same velocity. This indicates that an efflux pump becomes overloaded at concentrations above 210 mg F/L. Uptake kinetics were simulated with a non-linear mathematical model, and the Michaelis-Menten parameters were determined to half-saturation constant KM near 2 g F/L and maximum enzymatic removal rate vmax at 9 g/(kg d). PMID:25409250

  10. Argon Laser Photoablation for Treating Benign Pigmented Conjunctival Nevi

    Science.gov (United States)

    Alsharif, Abdulrahman M.; Al-Gehedan, Saeed M.; Alasbali, Tariq; Alkuraya, Hisham S.; Lotfy, Nancy M.; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the outcomes of argon laser photoablation of benign conjunctival pigmented nevi with different clinical presentations. Patients and Methods: This interventional case series was conducted between July 2014 and January 2015. Patients presenting with benign conjunctival nevi were included. Data were collected on the clinical features at presentation, argon laser photoablation, and follow-up at 8 and 24 weeks. Postoperative photography allowed recording of the success of each case and the overall success rate. Complete removal of conjunctival pigments was considered an absolute success. Partial pigmentation requiring repeat laser treatment was considered a qualified success. Results: There were 14 eyes (four right eyes and ten left eyes) with benign pigmented conjunctival nevi. There were three males and eight females in the study sample. The median age was 36 (25% percentile: 26 years). Three patients had bilateral lesions. The nevi were located temporally in nine eyes, nasally in three eyes, and on the inferior bulbar conjunctiva in two eyes. The mean horizontal and vertical diameters of nevi were 5 ± 2 mm and 4 ± 2.7 mm, respectively. The mean follow-up period was 5 months. Following laser treatment, no eyes had subconjunctival hemorrhage, infection, scarring, neovascularization, recurrence, or corneal damage. The absolute success rate of laser ablation was 79%. Three eyes with elevated nevi had one to three sessions of laser ablation resulting in a qualified success rate of 100%. Conclusions: Argon laser ablation was a safe and effective treatment for the treatment of selective benign pigmented conjunctival nevi in Arab patients. PMID:27555708

  11. Sodium aerosol formation in an argon flow over hot sodium

    International Nuclear Information System (INIS)

    Vapour evaporation, which partly forms aerosol, occurs when a cold gas flows over a hot liquid. A previous well-mixed model is extended to predict the final vapour plus aerosol content of such a flow in terms of its initial and final temperatures. The predictions are compared to results of the Copacabana II experiment in which argon passed over a sodium pool. Agreement is obtained for the final sodium density at moderate flow rates, and physical reasons are given as to why deviations occur at low and high flow rates. (author)

  12. Performance of the TGT liquid argon calorimeter and trigger system

    International Nuclear Information System (INIS)

    A novel concept of a liquid argon calorimeter, the 'Thin Gap Turbine' (TGT) calorimeter, is presented. A TGT test module, equipped with specially developed cold front-end electronics in radiation hard GaAs technology, has been operated in a particle beam. Results on its performance are given. A 40 MHz FADC system with a 'circular data store' and standalone readout and playback capability has been developed to test the properties of the TGT detector for trigger purposes. Results on trigger efficiency, response and energy resolution are given. 12 refs., 21 figs., 6 tabs

  13. Optical fiber read-out for liquid argon scintillation light

    CERN Document Server

    Csáthy, J Janicskó; Kratz, J; Schönert, S; Wiesinger, Ch

    2016-01-01

    In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high purity germanium (HPGe) detectors operated directly in liquid Argon (LAr). Background suppression efficiencies for different radioactive sources were measured in a test cryostat with about 800 kg LAr. This work was part of the R\\&D effort for the GERDA experiment.

  14. HARP: high-pressure argon readout for calorimeters

    International Nuclear Information System (INIS)

    Steel tubes of approximately 8 mm O.D., filled with Argon gas to approx. 200 bar, are considered as the active element for a charge collecting sampling calorimeter readout system. The tubes are permanently sealed and operated in the ion chamber mode, with the charge collection on a one-millimeter concentric anode. We present the motivation for such a device, including Monte Carlo predictions of performance. The method of construction and signal collection are discussed, with initial results on leakage and ageing of the filling gas. A prototype electromagnetic calorimeter is described

  15. Modeling of an argon cascaded arc plasma by ANSYS FLUENT

    International Nuclear Information System (INIS)

    In this work, an argon cascaded arc plasma is simulated by the business software ANSYS FLUENT. In fact, thus plasma is a high temperature arc (plasma window) with an average temperature of 12000 °C, which can be used as a medium between high pressure and vacuum mainly due to its characteristics of high temperature. According to the simulating results, the temperature can reach as high as 11500 °C which is in great agreement with that of other reports about plasma window.

  16. Diffusion coefficient of metal vapours into rare gases. Mercury - argon

    International Nuclear Information System (INIS)

    The source information is present as well as the results of analysis and integration of data on mutual diffusion coefficient (MDC) of mercury - argon mixture at Hg concentration → 0 in 300-2500 K temperature range. Reference data on MDC for metal - inert gas binary mixtures obtained on the base of complex analysis of various information, as it exemplified by Hg-Ar pair, can be used as a part of metrological support at calibration of devices for determination MDC of gas - metal vapors

  17. Searching for dark matter with single phase liquid argon

    Science.gov (United States)

    Caldwell, Thomas S., Jr.

    The first hint that we fail to understand the nature of a large fraction of the gravitating matter in the universe came from Fritz Zwicky's measurements of the velocity distribution of the Coma cluster in 1933. Using the Virial theorem, Zwicky found that galaxies in the cluster were orbiting far too fast to remain gravitationally bound when their mass was estimated by the brightness of the visible matter. This led to the postulation that some form of non-luminous dark matter is present in galaxies comprising a large fraction of the galactic mass. The nature of this dark matter remains yet unknown over 80 years after Zwicky's measurements despite the efforts of many experiments. Dark matter is widely believed to be a beyond the Standard Model particle which brings the dark matter problem into the realm of particle physics. Supersymmetry is one widely explored extension of the Standard model, from which particles meeting the constraints on dark matter properties can naturally arise. These particles are generically termed weakly interacting massive particles (WIMPs), and are a currently favored dark matter candidate. A variety of experimental efforts are underway aimed towards direct detection of dark matter through observation of rare scattering of WIMPs in terrestrial detectors. Single phase liquid argon detectors are an appealing WIMP detection technique due to the scintillation properties of liquid argon and the scalability of the single phase approach. The MiniCLEAN dark matter detector is a single phase liquid argon scintillation scintillation detector with a 500 kg active mass. The modular design offers 4pi coverage with 92 optical cassettes, each containing TPB coated acrylic and a cryogenic photomultiplier tube. The MiniCLEAN detector has recently completed construction at SNOLAB. The detector is currently being commissioned, and will soon begin operation with the liquid argon target. Utilizing advanced pulse-shape discrimination techniques, MiniCLEAN will

  18. Penning transfer in argon-based gas mixtures

    CERN Document Server

    Sahin, O; Tapan, I; Ozmutlu, E N

    2010-01-01

    Penning transfers, a group of processes by which excitation energy is used to ionise the gas, increase the gas gain in some detectors. Both the probability that such transfers occur and the mechanism by which the transfer takes place, vary with the gas composition and pressure. With a view to developing a microscopic electron transport model that takes Penning transfers into account, we use this dependence to identify the transfer mechanisms at play. We do this for a number of argon-based gas mixtures, using gain curves from the literature.

  19. The main properties of microwave argon plasma at atmospheric pressure

    International Nuclear Information System (INIS)

    Plasma torch sustained by surface wave at atmospheric pressure is theoretically studied by means of 1D model. A steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge is numerically solved together with Maxwell's equations for an azimuthally symmetric TM surface wave. The axial dependences of the electrons, excited atoms, atomic and molecular ions densities as well as the electron temperature, the mean power per electron and the effective electron-neutral collision frequency are determined. A strong dependence of the plasma properties on the discharge conditions and the gas temperature is obtained.

  20. Study of a Novel Concept for a Liquid Argon Calorimeter \

    CERN Multimedia

    2002-01-01

    % RD33 \\\\ \\\\ The development of a fast, highly granular and compact electromagnetic liquid argon calorimeter prototype is proposed as a generic R\\&D project for a novel concept of calorimetry in proton-proton and electron-positron collider detectors: the $^{\\prime$Thin Gap Turbine$^{\\prime}$ (TGT). The TGT calorimeter has a modular construction, is flexible in its longitudinal and transverse granularity, and offers a uniform energy response and resolution, independent of the production angle of incident particles. An important aspect of the project is the development of fast, radiation-hard front-end electronics which is operating in the cold.

  1. Intracavity frequency doubling in a wide-aperture argon laser

    International Nuclear Information System (INIS)

    The four-mirror cavity with a BBO crystal for frequency doubling in a wide-aperture argon laser is optimised. The dependences of the second-harmonic power on the displacement of a focusing mirror, the displacement of the crystal, and the discharge current are measured. These dependences are in good agreement with calculations. After optimisation, ∼1 W of UV laser radiation at 244 nm was obtained with the conversion efficiency twice as large as that for the known similar lasers. It is shown that the increase in the efficiency was achieved mainly due to the increase in the discharge-tube aperture. (nonlinear optical phenomena)

  2. High intensity, argon ion laser-jet photochemistry

    Science.gov (United States)

    Wilson, R. Marshall; Schnapp, Karlyn A.; Hannemann, Klaus; Ho, Douglas M.; Memarian, Hamid R.; Azadnia, Ardeshir; Pinhas, Allan R.; Figley, Timothy M.

    A new technique for the study of high intensity solution photochemistry has been developed. With this laser-jet technique, a high velocity microjet is irradiated with the focussed output of an argon ion laser. Under these extremely high intensity conditions, photochemically generated transient species with suitable absorption properties are excited further and produce relatively large amounts of photoproducts which are not observed under low intensity conditions. The application of this laser-jet technique in the study of the photochemistry of radicals, biradicals, photoenols and the higher excited states of carbonyl and polycyclic aromatic compounds is described.

  3. The main properties of microwave argon plasma at atmospheric pressure

    Science.gov (United States)

    Benova, E.; Pencheva, M.

    2010-01-01

    Plasma torch sustained by surface wave at atmospheric pressure is theoretically studied by means of 1D model. A steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge is numerically solved together with Maxwell's equations for an azimuthally symmetric TM surface wave. The axial dependences of the electrons, excited atoms, atomic and molecular ions densities as well as the electron temperature, the mean power per electron and the effective electron-neutral collision frequency are determined. A strong dependence of the plasma properties on the discharge conditions and the gas temperature is obtained.

  4. The main properties of microwave argon plasma at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Benova, E; Pencheva, M, E-mail: benova_phys@deo.uni-sofia.b [Department for Language Teaching and International Students, University of Sofia, 27 Kosta Loulchev Street, BG-1111 Sofia (Bulgaria)

    2010-01-01

    Plasma torch sustained by surface wave at atmospheric pressure is theoretically studied by means of 1D model. A steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge is numerically solved together with Maxwell's equations for an azimuthally symmetric TM surface wave. The axial dependences of the electrons, excited atoms, atomic and molecular ions densities as well as the electron temperature, the mean power per electron and the effective electron-neutral collision frequency are determined. A strong dependence of the plasma properties on the discharge conditions and the gas temperature is obtained.

  5. Laser-induced vibrational dynamics of ozone in solid argon

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; Amstrup, B.; Henriksen, Niels Engholm

    1997-01-01

    We consider the vibrational dynamics, induced by an intense infrared laser pulse, in an ozone molecule with isotopic substitution, that is, (OOO)-O-16-O-16-O-18 and compare the dynamics in the gas phase and in solid ar on. not perturbed by argon on a time-scale of a few picoseconds and selective...... bond-breaking in the molecule should be possible following the same laser control scheme as suggested in the gas phase. (C) 1997 Elsevier Science B.V....

  6. Electron transport in argon in crossed electric and magnetic fields

    Science.gov (United States)

    Ness; Makabe

    2000-09-01

    An investigation of electron transport in argon in the presence of crossed electric and magnetic fields is carried out over a wide range of values of electric and magnetic field strengths. Values of mean energy, ionization rate, drift velocity, and diffusion tensor are reported here. Two unexpected phenomena arise; for certain values of electric and magnetic field we find regions where the swarm mean energy decreases with increasing electric fields for a fixed magnetic field and regions where swarm mean energy increases with increasing magnetic field for a fixed electric field. PMID:11088933

  7. Ionization coefficients for argon in a micro-discharge

    International Nuclear Information System (INIS)

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges. (paper)

  8. Kinetic modeling of the Townsend breakdown in argon

    Science.gov (United States)

    Macheret, S. O.; Shneider, M. N.

    2013-10-01

    Kinetic modeling of the Townsend breakdown in argon was performed in the "forward-back" approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  9. Ionization coefficients for argon in a micro-discharge

    Science.gov (United States)

    Kuschel, Thomas; Stefanović, Ilija; Malović, Gordana; Marić, Dragana; Petrović, Zoran Lj

    2013-08-01

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges.

  10. Argon Analyses of Lherzolic Shergottites Y984028 and Y000097

    Science.gov (United States)

    Park, J.; Nyquist, L. E.; Bogard, D. D.; Garrison, D. H.; Shih, C.-Y.; Mikouchi, T.; Misawa, K.

    2010-01-01

    Antarctic Martian meteorites Yamato (Y) 984028 and Y000027/47/97 have similar textures, mineralogy, chemistry, and isotopic composition and are possibly paired. We analyzed the argon isotopic composition of Y984028 whole rock (WR) and pyroxene mineral separates (Px) in order to evaluate their trapped Ar components and compare with Y000097 Ar data. WR and Px yield an apparent Ar-39-Ar-40 age spectra of roughly 2 Ga, much older than the crystallization age determined by other isotopic techniques. Sm-Nd and Rb-Sr ages for Y984028 are approximately 170 Ma. This discrepancy is likely the byproduct of several coexisting Ar components, such as radiogenic 40Ar*, cosmogenic Ar, and trapped Ar from the multiple minerals, as well as multiple source origins. Similarly, the reported Ar-39-Ar-40 age of Y000097 is approximately 260 Ma with a Rb-Sr age of 147+/- 28 Ma and a Sm-Nd age of 152 +/- 13 Ma [4]. Apparently Ar-Ar ages of both Y984028 and Y000097 show trapped Ar components. Stepwise temperature extractions of Ar from Y984028 Px show several Arcomponents released at different temperatures. For example, intermediate temperature data (800-1100 C) are nominally consistent with the Sm-Nd and Rb-Sr radiometric ages (approximately 170 Ma) with an approximately Martian atmosphere trapped Ar composition with a Ar-40-Ar-36 ratio of approximately 1800. Based on K/Ca distribution, we know that Ar-39 at both lower and intermediate temperatures is primarily derived from plagioclase and olivine. Argon released during higher temperature extractions (1200-1500 C), however, differs significantly. The thermal profile of argon released from Martian meteorites is complicated by multiple sources, such as Martian atmosphere, Martian mantle, inherited Ar, terrestrial atmosphere, cosmogenic Ar. Obviously, Ar release at higher temperatures from Px should contain little terrestrial atmospheric component. Likewise, Xe-129/Xe-132 from high temperature extractions (1200-1800 C) gives a value above that

  11. Above threshold ionization of Argon atoms by multicolor XUV radiation

    International Nuclear Information System (INIS)

    We analyse theoretically the Argon photoelectron spectra produced by strong and extreme ultraviolet radiation of six colors: from the 11th to the 16th harmonics of ω0 (800nm). In particular we concentrate in the range of the spectra where absorption of two photons occurs. The combination of photons of different frequencies results in eleven peaks that are separated by ω0. We point out that their relative intensities are very sensitive to the laser pulse parameters and target description. We also compare the theoretical description with experimental results finding good qualitative agreement

  12. Charges recombination in α particle tracks in argon

    International Nuclear Information System (INIS)

    The creation and evolution of (neutral) excited states and ionized states in α particle tracks in high pressure argon are studied. The main features of recently published experimental results on the recombination luminescence can be explained and a track model is proposed. Details are given on the track radius, on the electrons thermallization, and on collisions between electrons and triplet excited states. The most important result is that at high pressure and high electron and ion densities a collective electron-ion recombination is possible, that is more efficient that the well known dissociative recombination

  13. Activation of copper by nitrogen and argon beams

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkova, Vera [IAP, Goethe-University, Frankfurt am Main (Germany); GSI Darmstadt (Germany); Mustafin, Edil; Strasik, Ivan [GSI Darmstadt (Germany); Belousov, Anton [TU Darmstadt (Germany); Latysheva, Ludmila; Sobolevsky, Nikolai [INR RAS, Moscow (Russian Federation); Ratzinger, Ulrich [IAP, Goethe-University, Frankfurt am Main (Germany)

    2012-07-01

    Monte Carlo transport codes are widely used for various purposes in nuclear physics, radiation protection, medical applications, accelerator design etc. Code verification by experiments is needed to be sure that the codes give accurate results. New data on the activation of copper by a nitrogen beam of 500 MeV/u is presented and compared with FLUKA and SHIELD simulation results. The activation of copper by a nitrogen beam is compared to activation by an argon beam and respective simulations. This gives a chance to see the accuracy of the codes at different projectile masses. Correspondences and discrepancies of calculations and experiments are discussed.

  14. Electron drift velocity in argon-methane mixture

    International Nuclear Information System (INIS)

    Described are the results of a series of measurements of electron drift velocity taken with samples of chemically pure grade gas mixture of Ar-10% CH4 (N2222O<2 ppm). The measured drift velocity is plotted as a function of the ratio of electric field to pressure in the range from 0.05 to 0.8 V/cmxtorr. The measurements are reproducible only to within 4%. The results of numerical calculations employing the well-established argon elastic and methane elastic and inelastic cross sections are also included. The disagreement from the present experimental results, and from those obtained elsewhere, is rather puzzling

  15. Study of a novel electromagnetic liquid argon calorimeter TGT

    International Nuclear Information System (INIS)

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a test beam exposure. 15 refs., 16 figs., 2 tabs

  16. Chemico-therapeutic approach to prevention of dental caries. [using stannous fluoride gel

    Science.gov (United States)

    Shannon, I. L.

    1975-01-01

    The program of chemical preventive dentistry is based primarily upon the development of a procedure for stabilizing stannous fluoride in solution by forcing it into glycerin. New topical fluoride treatment concentrates, fluoride containing gels and prophylaxis pastes, as well as a completely stable stannous fluoride dentifrice are made possible by the development of a rather complicated heat application method to force stannous fluoride into solution in glycerin. That the stannous fluoride is clinically effective in such a preparation is demonstrated briefly on orthodontic patients.

  17. The effect of different fluoride application methods on the remineralization of initial carious lesions

    OpenAIRE

    Byeon, Seon Mi; Lee, Min Ho; Bae, Tae Sung

    2016-01-01

    Objectives The purpose of this study was to assess the effect of single and combined applications of fluoride on the amount of fluoride release, and the remineralization and physical properties of enamel. Materials and Methods Each of four fluoride varnish and gel products (Fluor Protector, FP, Ivoclar Vivadent; Tooth Mousse Plus, TM, GC; 60 Second Gel, A, Germiphene; CavityShield, CS, 3M ESPE) and two fluoride solutions (2% sodium fluoride, N; 8% tin(ii) fluoride, S) were applied on bovine t...

  18. Characterization of cerium fluoride nanocomposite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Stange, Sy [Los Alamos National Laboratory; Esch, Ernst I [Los Alamos National Laboratory; Brown, Leif O [Los Alamos National Laboratory; Couture, Aaron J [Los Alamos National Laboratory; Mckigney, Edward A [Los Alamos National Laboratory; Muenchausen, Ross E [Los Alamos National Laboratory; Del Sesto, Rico E [Los Alamos National Laboratory; Gilbertson, Robert D [Los Alamos National Laboratory; Mccleskey, T Mark [Los Alamos National Laboratory; Reifarth, Rene [Los Alamos National Laboratory

    2009-01-01

    Measurement of the neutron capture cross-sections of a number of short-lived isotopes would advance both pure and applied scientific research. These cross-sections are needed for calculation of criticality and waste production estimates for the Advanced Fuel Cycle Initiative, for analysis of data from nuclear weapons tests, and to improve understanding of nucleosynthesis. However, measurement of these cross-sections would require a detector with a faster signal decay time than those used in existing neutron capture experiments. Crystals of faster detector materials are not available in sufficient sizes and quantities to supply these large-scale experiments. Instead, we propose to use nanocomposite detectors, consisting of nanoscale particles of a scintillating material dispersed in a matrix material. We have successfully fabricated cerium fluoride (CeF{sub 3}) nanoparticles and dispersed them in a liquid matrix. We have characterized this scintillator and have measured its response to neutron capture. Results of the optical, structural, and radiation characterization will be presented.

  19. Magnetic separation of uranium from magnesium fluoride

    International Nuclear Information System (INIS)

    The attraction or repulsion of particles by a magnetic gradient, based on the respective susceptibilities, provides the basis for physical separation of particles that are comprised predominantly of uranium from those that are predominantly magnesium fluoride (MgF2). To determine the effectiveness of this approach, a bench-scale magnetic separator from the S.G. Frantz Co., Inc. was used. In the Frantz Model L-1, particles are fed through a funnel onto a vibration tray and through a magnetic field. The specific design of the Frantz magnet causes the magnetic field strength to vary along the width of the magnet, setting up a gradient. The tray in the magnetic field is split at a point about half way down its length so that the separated material does not recombine. A schematic is presented of Frantz Model L-1 CN - the same magnet configured for high gradient magnetic separation of liquid-suspended particles. Here different pole pieces create a uniform magnetic field, and stainless steel wood in the canister between the pole pieces creates the high gradient. 1 ref., 6 figs., 2 tabs

  20. Characterization of cerium fluoride nanocomposite scintillators

    International Nuclear Information System (INIS)

    Measurement of the neutron capture cross-sections of a number of short-lived isotopes would advance both pure and applied scientific research. These cross-sections are needed for calculation of criticality and waste production estimates for the Advanced Fuel Cycle Initiative, for analysis of data from nuclear weapons tests, and to improve understanding of nucleosynthesis. However, measurement of these cross-sections would require a detector with a faster signal decay time than those used in existing neutron capture experiments. Crystals of faster detector materials are not available in sufficient sizes and quantities to supply these large-scale experiments. Instead, we propose to use nanocomposite detectors, consisting of nanoscale particles of a scintillating material dispersed in a matrix material. We have successfully fabricated cerium fluoride (CeF3) nanoparticles and dispersed them in a liquid matrix. We have characterized this scintillator and have measured its response to neutron capture. Results of the optical, structural, and radiation characterization will be presented.

  1. Thermodynamic data for treatment of fluoride

    International Nuclear Information System (INIS)

    To obtain uranium from Al2O3 with uranium by the electrolytic deduction method, the equilibrium potential of Ni(0)/Ni(2) in NaF-AlF3-Al2O3-NiF2 and its dependence on the concentration of Al2O3 were determined. On the coexistence system of Al2O3 and NiF2 in the molten salt, NiF2 was oxidized to NiO by the oxygen ion from Al2O3. Dependence of the equilibrium potential of Ni(0)/Ni(2) in NaF-AlF3-NiF2 on temperature was measured and the potential data were consistent with the Nernst equation, which showed the large effect of Al2O3 on oxidation of metallic fluoride in molten salt. These results proved that the stripping treatment of uranium in the coexistence system of Al2O3 by the electrolytic deduction method was difficult, because the effect of oxygen ion of Al2O3 was larger than the level of oxidation- reduction potential. (S.Y.)

  2. Magnetic separation of uranium from magnesium fluoride

    Energy Technology Data Exchange (ETDEWEB)

    Hoegler, J.M.

    1987-01-01

    The attraction or repulsion of particles by a magnetic gradient, based on the respective susceptibilities, provides the basis for physical separation of particles that are comprised predominantly of uranium from those that are predominantly magnesium fluoride (MgF/sub 2/). To determine the effectiveness of this approach, a bench-scale magnetic separator from the S.G. Frantz Co., Inc. was used. In the Frantz Model L-1, particles are fed through a funnel onto a vibration tray and through a magnetic field. The specific design of the Frantz magnet causes the magnetic field strength to vary along the width of the magnet, setting up a gradient. The tray in the magnetic field is split at a point about half way down its length so that the separated material does not recombine. A schematic is presented of Frantz Model L-1 CN - the same magnet configured for high gradient magnetic separation of liquid-suspended particles. Here different pole pieces create a uniform magnetic field, and stainless steel wood in the canister between the pole pieces creates the high gradient. 1 ref., 6 figs., 2 tabs.

  3. Investigation of solubility of cesium, strontium, barium, rare-earth, uranium and americium fluorides in acid nitrosyl fluoride (NOFx3HF)

    International Nuclear Information System (INIS)

    Solubility of Am and other elements, which are fission products, in acid nitrosylfluoride has been studied. Cesium fluoride has maximum solubility; uranium tetrafluoride is also noticeably soluble; americium trifluoride is practically insoluble; fluorides of rare earth elements are slightly soluble in NOFx3HF. Analysis of the solid phase obtained after treating the mixture of the above fluorides with acid nitrosylfluoride has shown that cesium fluoride reacts with NOFx3HF with the formation of an acid salt (CsFxHF), whereas fluorides of alkaline and rare earth elements remain unchanged. The behaviour of a mixture of cesium, barium, and lanthanum fluorides in the process of three-multiple treating with acid nitrosylfluoride has been studied. It is shown that more than 98% of cesium fluoride and 5% of barium fluoride pass into the mother liquor while lanthanum fluoride remains completely in the solid phase. The data on americium fluoride solubility in acid nitrosylfluoride have indicated that it behaves in the same way as fluorides of rare earth elements; it is practically insoluble in HOFx3HF

  4. Profile of Fluoride Release from a Nanohybrid Composite Resin

    Directory of Open Access Journals (Sweden)

    Raquel Assed Bezerra Silva

    2015-02-01

    Full Text Available The aim of this study was to evaluate in vitro the amount and profile of fluoride release from a fluoride-containing nanohybrid composite resin (Tetric® N-Ceram by direct potentiometry. Thirty specimens (5 mm diameter x 3 mm high; n=10/material were made of Tetric® N-Ceram, Vitremer® resin-modified glass ionomer cement (RMGIC (positive control or Filtek® Z350 nanofill composite resin (negative control. The specimens were stored individually in plastic tubes containing 1 mL of artificial saliva at 37°C, which was daily renewed during 15 days. At each renewal of saliva, the amount of fluoride ions released in the solution was measured using a fluoride ion-selective electrode with ion analyzer, and the values obtained in mV were converted to ppm (µg/mL. Data were analyzed statistically by ANOVA and Tukey’s post-hoc test at a significance level of 5%. The results showed that the resins Tetric® N-Ceram and Filtek® Z350 did not release significant amounts of fluoride during the whole period of evaluation (p>0.05. Only Vitremer® released significant amounts of fluoride ions during the 15 days of the experiment, with greater release in first 2 days (p0.05. In conclusion, the nanohybrid composite resin Tetric® N-Ceram did not present in vitro fluoride-releasing capacity throughout the 15 days of study.

  5. Kinetic modelling of krypton fluoride laser systems

    International Nuclear Information System (INIS)

    A kinetic model has been developed for the KrF* rare gas halide laser system, specifically for electron-beam pumped mixtures of krypton, fluorine, and either helium or argon. The excitation produced in the laser gas by the e-beam was calculated numerically using an algorithm checked by comparing the predicted ionization yields in the pure rare gases with their experimental values. The excitation of the laser media by multi-kilovolt x-rays was also modeled and shown to be similar to that produced by high energy electrons. A system of equations describing the transfer of the initial gas excitation into the laser upper level was assembled using reaction rate constants from both experiment and theory. A one-dimensional treatment of the interaction of the laser radiation with the gas was formulated which considered spontaneous and stimulated emission and absorption. The predictions of this model were in good agreement with the fluorescence signals and gain and absorption measured experimentally

  6. Measurements of the ratio between the transverse diffusion coefficient and the mobility for argon ions in argon

    International Nuclear Information System (INIS)

    The ratio DT/μ between the transverse diffusion coefficient and the mobility for 40Ar+ ions in argon has been determined from directly measured transverse current density distribution profiles of mass-analysed ions, as a function of the ratio E/n0 between the electric field and the gas number density in the interval 50≤E/n0≤4000 Td, at gas temperature T=294 K using a variable-length drift tube mass spectrometer. The error (two standard deviations) in the results is believed to be less than ±4% for E/n0o-values. (author)

  7. Stabilization of fluoroindate glasses by magnesium fluoride and other heavy metal fluorides

    Directory of Open Access Journals (Sweden)

    B. J. Costa

    1998-06-01

    Full Text Available Their extended transparency in the IR makes them attractive for use as optical fibers for CO laser power delivery and optical amplification. This paper firstly describes the spectacular stabilizing effect of MgF2 on the binary system InF3-BaF2. The investigation of the InF3-BaF2-MgF2 system led to samples up to 5mm in thickness. Further optimization of this system was achieved by incorporation of limited amounts of other fluorides and resulted in increased resistence to devitrification. The second approach of this work was concerned to the investigation of the pseudo-ternary system InF3-GdF3-GaF3 at constant concentrations of ZnF2-SrF2-BaF2-NaF. Several compositions were studied in this system. The samples presented a better thermal stability when compared to other families of fluoride glasses. Therefore, these glasses seem to be very promising for the fabrication of special optical fibers. Thermal data are reported.

  8. Electrochemical properties of uranium, cerium, and zirconium in the lithium fluoride - barium fluoride eutectic

    International Nuclear Information System (INIS)

    The aim of this work has been to determine the possibility of carrying out an electrochemical analysis of the ions U4+, Ce3+, Zr4+ in a fluoride melt, and to obtain some of the electrochemical properties of these ions. It was first of all necessary to develop a method for purifying the LiF-BaF2 eutectic so as to have melts of sufficient purity for carrying out an electrochemical study using linear chrono-amperometry and chrono-potentiometry. The polarization curves recorded in solutions for the ions U4+, Ce3+, Zr4+ show that the systems U4+/U3+, Ce3+/Ce4+ and Zr4+/Zr are rapid. After it had been checked that mass transport on the electrode is controlled by diffusion, the diffusion coefficients for the ions Ce3+, U4+ and Zr4+ were determined. The oxidizing nature of the ion Ce4+ makes it possible to dissolve ceric oxide in the molten fluoride. Furthermore the existence of two zirconium oxyfluorides has been demonstrated, they appear after dissolution of the zirconia in a solution of zirconium tetrafluoride. From a practical point of view these results are of interest for the preparation of metals by electrolytic reduction of their oxides. (author)

  9. A liquid argon scintillation veto for the GERDA experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10-3 cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  10. A liquid argon scintillation veto for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10{sup -3} cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  11. Compilation of electron collision excitation cross sections for neutro argon

    International Nuclear Information System (INIS)

    The present work presents a compilation and critical analysis of the available data on electron collision excitation cross sections for neutral Argon levels. This study includes: 1.- A detailed description in intermediate coupling for all the levels belonging the 20 configurations 3p''5 ns(n=4 to 12), np(n=4 to 8) and nd(n=3 to 8) of neutral Argon. 2.- Calculation of the electron collision excitation cross sections in Born and Born-Oppenheimer-Ochkur approximations for all the levels in the 14 configurations 3p''5 ns(n=4 to 7), np(n=4 to 7) and nd(n=3 to 8). 3.- Comparison and discussion of the compiled data. These are the experimental and theoretical values available from the literature, and those from this work. 4.- Analysis of the regularities and systematic behaviors in order to determine which values can be considered more reliable. It is show that the concept of one electron cross section results quite useful for this purpose. In some cases it has been possible to obtain in this way approximate analytical expressions interpolating the experimental data. 5.- All the experimental and theoretical values studied are graphically presented and compared. 6.- The last part of the work includes a listing of several general purpose programs for Atomic Physics calculations developed for this work. (Author)

  12. Model of a stationary microwave argon discharge at atmospheric pressure

    International Nuclear Information System (INIS)

    The many applications of microwave gas discharges at atmospheric pressure in various fields of science, technology and medicine require an adequate model of these discharges. Such a model is based on the electromagnetic wave's propagation properties and on the elementary processes in the discharge bulk. In contrast to the microwave discharges at low-gas pressures, where many elementary processes might be ignored because of their negligible contribution to the electron and heavy particle's balance equations, for such discharges at atmospheric pressure the consideration of a large number of collisional processes is mandatory. For the build of a successful discharge-column model one needs three important quantities, notably the power θ necessary for sustaining an electron - ion pair, electron - neutral collision frequency for momentum transfer ven, and gas temperature Tg. The first two key parameters are obtained by a collisional-radiative model of the argon at atmospheric pressure, while the microwave frequency ω/2π = 2.45 GHz, plasma column radius R, gas pressure p and gas temperature Tg are fixed external parameters determined by the experimental conditions. Here, we present a model of a capillary argon microwave plasma column with a length L ≅ 14 cm, sustained by wave power of 110 W - the model yields the longitudinal distributions of the plasma density, expended wave power, wave electric field magnitude, and complex wave number

  13. Analysis of microdischarges in asymmetric dielectric barrier discharges in argon

    International Nuclear Information System (INIS)

    Theoretical and experimental studies of two different discharge modes in asymmetric dielectric barrier discharges in argon at atmospheric pressure have been performed. The first mode appears to be the well-known filamentary microdischarge with non-striated positive column whereas the second mode is characterized by discharge instabilities and the appearance of striations. Both experiment and model calculations predict a transition from the first mode to the second mode when the applied voltage amplitude is increased above approximately 2 kV. The reliability of the employed fluid model is confirmed by comparison of the current–voltage characteristics obtained by model calculations and measurements for different applied voltage amplitudes. The results of the model calculations point out that in the second discharge mode the ionization of excited argon atoms prevents the total recombination of charge carriers between two subsequent discharge events. This leads to the occurrence of the memory from one discharge to the following one, which plays an important role in mode transition. (paper)

  14. Model of a stationary microwave argon discharge at atmospheric pressure

    Science.gov (United States)

    Zhelyazkov, I.; Pencheva, M.; Benova, E.

    2008-03-01

    The many applications of microwave gas discharges at atmospheric pressure in various fields of science, technology and medicine require an adequate model of these discharges. Such a model is based on the electromagnetic wave's propagation properties and on the elementary processes in the discharge bulk. In contrast to the microwave discharges at low-gas pressures, where many elementary processes might be ignored because of their negligible contribution to the electron and heavy particle's balance equations, for such discharges at atmospheric pressure the consideration of a large number of collisional processes is mandatory. For the build of a successful discharge-column model one needs three important quantities, notably the power θ necessary for sustaining an electron—ion pair, electron—neutral collision frequency for momentum transfer ven, and gas temperature Tg. The first two key parameters are obtained by a collisional-radiative model of the argon at atmospheric pressure, while the microwave frequency ω/2π = 2.45 GHz, plasma column radius R, gas pressure p and gas temperature Tg are fixed external parameters determined by the experimental conditions. Here, we present a model of a capillary argon microwave plasma column with a length L ≈ 14 cm, sustained by wave power of 110 W—the model yields the longitudinal distributions of the plasma density, expended wave power, wave electric field magnitude, and complex wave number.

  15. Liquid argon scintillation read-out with silicon devices

    International Nuclear Information System (INIS)

    Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R and D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm2 area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R and D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of 76Ge

  16. Elastic properties of liquid and solid argon in nanopores.

    Science.gov (United States)

    Schappert, Klaus; Pelster, Rolf

    2013-10-16

    We have measured sorption isotherms and determined the intrinsic longitudinal elastic modulus β(Ar,ads) of nanoconfined material via ultrasonic measurements combined with a special effective medium analysis. In the liquid regime the adsorbate only contributes to the measured effective properties when the pores are completely filled and the modulus is bulklike. At partial fillings its contribution is cancelled out by the high compressibility of the vapour phase. In contrast, at lower temperatures frozen argon as well as underlying liquid surface layers cause a linear increase of the effective longitudinal modulus upon filling. During sorption the contribution of the liquid surface layers near the pore wall β(Ar,surf) increases with the thickness of the solid layers reaching the bulk value β(Ar,liquid) only in the limit of complete pore filling. We interpret this effect as due to the gradual stiffening of the solid argon membrane. The measurements and their analysis show that longitudinal ultrasonic waves are well suited to the study of the elastic properties and liquid-solid phase transitions in porous systems. This method should also help to detect the influence of nanoconfinement on elastic properties in further research. PMID:24057946

  17. Liquid argon scintillation read-out with silicon devices

    Science.gov (United States)

    Canci, N.; Cattadori, C.; D'Incecco, M.; Lehnert, B.; Machado, A. A.; Riboldi, S.; Sablone, D.; Segreto, E.; Vignoli, C.

    2013-10-01

    Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R&D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm2 area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R&D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of 76Ge.

  18. Investigation of a Mercury-Argon Hot Cathode Discharge

    Science.gov (United States)

    Wamsley, Robert Charles

    Classical absorption and laser induced fluorescence (LIF) experiments are used to investigate processes in the cathode region of a Hg-Ar hot cathode discharge. The absorption and LIF measurements are used to test the qualitative understanding and develop a quantitative model of a hot cathode discharge. The main contribution of this thesis is a model of the negative glow region that demonstrates the importance of Penning ionization to the ionization balance in the negative glow. We modeled the excited argon balance equation using a Monte Carlo simulation. In this simulation we used the trapped radiative decay rate of the resonance levels and the Penning ionization rate as the dominant loss terms in the balance equation. The simulated data is compared to and found to agree with absolute excited argon densities measured in a classical absorption experiment. We found the primary production rate per unit volume of excited Ar atoms in the simulation is sharply peaked near the cathode hot spot. We used the ion production rate from this simulation and a Green's function solution to the ambipolar diffusion equation to calculate the contribution of Penning ionization to the total ion density. We compared the results of this calculation to our experimental values of the Hg ^+ densities in the negative glow. We found that Penning ionization is an important and possibly the dominant ionization process in the negative glow.

  19. Argon laser trabeculoplasty as primary therapy in open angle glaucoma

    International Nuclear Information System (INIS)

    To determine the effect of Argon Laser Trabeculoplasty (ALT) as a primary mode of therapy in reducing the intraocular Pressure (IOP) of patients diagnosed with Primary Open Angle Glaucoma (POAG). A total of 35 eyes of 35 patients with the gender distribution of 27 men and 8 women who were newly diagnosed with POAG, were included in this study. Mean age of the patients was 55.2 years with the range of 32 to 76 years. All of them were treated with argon laser trabeculoplasty as a primary mode of therapy. Intra ocular pressure was measured objectively using Goldman applanation tonometer, pre-and-post laser therapy. The pre-laser mean IOP was 27.63 mmHg (range 21-40 mmHg). The post-laser mean IOP measured at 6 months follow up was 15.5 mmHg (range 11 - 33 mmHg) with mean decrease of 12.1 mmHg. The decrease in IOP was seen in 32 eyes (95%) with no change observed in 3 (5%) eyes. The result shows a marked decline in IOP in patients with POAG who underwent ALT as a primary mode of treatment. Further studies with large sample size and longer follow-up will help in making future recommendations. (author)

  20. Dating of mineral samples through activation analysis of argon

    International Nuclear Information System (INIS)

    Mass Spectrometry has been the usual method to determine Ar concentrations in mineral samples for dating them through the 40Ar/40K ratio. This technique has been replaced since 1966 by measurement of 40Ar/39Ar ratio, after artificial production of 39Ar from the 39K(n,p)39Ar reaction produced in the fast neutron flux of a nuclear reactor. This method requires the fusion of the sample by incremental heating until reaching a temperature of 1000 deg C in order to get the total release of both argon isotopes. In principle, it should be possible to determine the 40Ar/40K ratio by activation analysis in an easier, non-destructive way, but it presents the following drawbacks: manufacture of argon standards; usual low ratio peak/Compton distribution for both peaks: 1.29 Mev and 1.52 Mev (41Ar and 42K respectively), since potassium minerals are usually very rich in sodium, manganese and chlorine; reaction 41K(n,p)41Ar induced by fast neutrons present in the thermal flux; and possible contamination of the samples and standards with atmospheric 40Ar(99.6% of elementary Ar, whose proportion in the atmosphere at sea level is 0.93%). This paper describes how these problems may be solved, also determining the limits of Ar and K concentration related to Compton distribution, in our experimental conditions. (author) 5 refs.; 1 tab