WorldWideScience

Sample records for argon fluorides

  1. Surface Chemistry of Polymers Physical Adsorption of Nitrogen, Argon, Sulfur Dioxide and Neopentane on Polyvinylidene Fluoride

    OpenAIRE

    Houriet, Jean-Philippe; Ghiste, Patrick; Stoeckli, Fritz

    2007-01-01

    The adsorption of nitrogen, argon, sulfur dioxide and neopentane on polyvinylidene fluoride has been measured by static methods and by gas-solid chromatography. The polymer has a homogeneous surface of low energy, which is not significantly affected by heating.

  2. Fluoride

    Science.gov (United States)

    Fluoride is used to prevent tooth decay. It is taken up by teeth and helps to strengthen ... and block the cavity-forming action of bacteria. Fluoride usually is prescribed for children and adults whose ...

  3. A comparative study to evaluate the effect of fluoride releasing sealant cured by visible light, argon laers, and light emitting diode curing units: An in vitro study

    Directory of Open Access Journals (Sweden)

    Das U

    2009-09-01

    Full Text Available In Pediatric Dentistry, the use of pit and fissure sealant is one of the essential forms of prevention. Pit and fissure caries may be substantially decreased by obliteration of these developmental defects in occlusal, buccal and lingual surfaces with resin based dental sealants. Visible light-curing units, or LCUs, are an integral part of modern adhesive dentistry" They are used to cure resin based composite restoration materials, resin modified glass-ionomer and pit and fissure sealants, as well as to bond orthodontic teeth. Most recently, the argon laser has been approved for initiating the setting reaction with visible light cured-resins. Argon curing of resin materials has been show to enhance the physical properties and degree of polymerization of the resin, while reducing the polymerization time by 75 percent. The study is undertaken considering the inadequate research reports of regarding the comparison of curing ability using argon laser. LEDs and visible light as well as the resistant towards caries activity of the preventive fluoride releasing pit and fissure sealant cured by above mentioned curing units.

  4. Fluoridated Water

    Science.gov (United States)

    ... Cancer Prevention Overview–for health professionals Research Fluoridated Water On This Page What is fluoride, and where is it found? What is water fluoridation? When did water fluoridation begin in the ...

  5. Bottled Water and Fluoride

    Science.gov (United States)

    ... Fluoridation Journal Articles for Community Water Fluoridation Bottled Water Recommend on Facebook Tweet Share Compartir Consumers drink ... questions about bottled water and fluoride. Does bottled water contain fluoride? Bottled water products may contain fluoride, ...

  6. Divalent fluoride doped cerium fluoride scintillator

    Science.gov (United States)

    Anderson, David F.; Sparrow, Robert W.

    1991-01-01

    The use of divalent fluoride dopants in scintillator materials comprising cerium fluoride is disclosed. The preferred divalent fluoride dopants are calcium fluoride, strontium fluoride, and barium fluoride. The preferred amount of divalent fluoride dopant is less than about two percent by weight of the total scintillator. Cerium fluoride scintillator crystals grown with the addition of a divalent fluoride have exhibited better transmissions and higher light outputs than crystals grown without the addition of such dopants. These scintillators are useful in radiation detection and monitoring applications, and are particularly well suited for high-rate applications such as positron emission tomography (PET).

  7. Metal fluorides

    International Nuclear Information System (INIS)

    Systems formed by fluorides of alkali, alkali earth, rare earth elements, yttrium, zirconium, hafnium, bismuth, antimony are investigated with the aim of preparing new fluoride materials and studying their thermodynamic and other physical and chemical properties. The respective phase diagrams are plotted. On the basis of the research fluoroberyllate glasses with rare earth additions of improved qualities (moisture resistance, crystallization resistance, resistance against radiation up to 100 Mrad) are prepared. The rho-T-x phase diagrams of the systems studied show that many compounds are sublimated congruently at certain temperatures and incongruently - above them. The existence of congruently sublimated compounds and azeotropically sublimated compositions provides for the preparation of uniform optical films. In connection with the search for new materials-luminophores and matrices of optical quantum generators - the fluoride systems of alkali metals and lanthanides are studied; the formation of binary fluorides of M3LnF6, M2LnF5, MLnF4, MLn2F7, MLn3F10 compositions is established. To search for new solid electrolytes, the solid-phase interaction of Sb-and Bi trifluorides with their oxides and alakali metal fluorides is studied. The electric conductivity of the compounds obtained is studied

  8. Fluoridation Basics

    Science.gov (United States)

    ... level in water is not enough to prevent tooth decay; however, some groundwater and natural springs can have ... the tooth’s surface, or enamel. Water fluoridation prevents tooth decay by providing frequent and consistent contact with low ...

  9. Depleted Argon from Underground Sources

    International Nuclear Information System (INIS)

    Argon is a strong scintillator and an ideal target for Dark Matter detection; however 39Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in 39Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO2 well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO2. We first concentrate the argon locally to 3% in an Ar, N2, and He mixture, from the CO2 through chromatographic gas separation, and then the N2 and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO2 facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

  10. Argon in action

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    Over the past few days, the SPS has been accelerating argon ions, which have started to be sent to the NA61/SHINE experiment. This operating mode, using a new type of ion, required a number of modifications to the accelerator.   Picture 1: a “super-cycle” of the SPS, featuring a proton cycle for the LHC, followed by an argon ion cycle for the North Area. Today, the accelerators are once again juggling particles and even performing completely new tricks. The SPS is supplying beams of argon ions for the first time, at energies never before achieved for this type of beam. They are destined for the NA61/SHINE experiment (see box) located in the North Area, which began receiving the beams on 11 February. Argon ions have a relatively large mass, as they consist of 40 nucleons, so they can be used in a similar way to lead ions. The main difficulty in accelerating them lies in the SPS, where the variation in acceleration frequency is limited. “The SPS was designed for a...

  11. Thermophysical properties of argon

    Energy Technology Data Exchange (ETDEWEB)

    Jaques, A.

    1988-02-01

    The entire report consists of tables of thermodynamic properties (including sound velocity, thermal conductivity and diffusivity, Prandtl number, density) of argon at 86 to 400/degree/K, in the form of isobars over 0.9 to 100 bars. (DLC)

  12. How Does Fluoride Work?

    Science.gov (United States)

    ... the mid-1940s, communities started to put more fluoride in their water supplies to protect people against tooth decay. Fluoride ... might suggest supplements — which are like vitamins containing fluoride. Just how effective is fluoridated water? Thanks to it, dentists say half of kids ...

  13. Fluoride varnish or fluoride mouth rinse?

    DEFF Research Database (Denmark)

    Keller, M K; Klausen, B J; Twetman, S

    2016-01-01

    OBJECTIVE: In many Danish communities, school-based fluoride programs are offered to children with high caries risk in adjunct to tooth brushing. The purpose of this field trial was to compare the caries-preventive effectiveness of two different fluoride programs in 6-12 year olds. BASIC RESEARCH...... different schools were enrolled after informed consent and their class unit was randomly allocated to one of two fluoride programs. INTERVENTIONS: One group received a semi-annual fluoride varnish applications (FV) and the other group continued with an existing program with fluoride mouth rinses once per...... in caries development over two years among children participating in a school-based fluoride varnish or mouth rinse program....

  14. Hair as Biomarker of Fluoride Exposure in a Fluoride Endemic Area and a Low Fluoridated Area

    OpenAIRE

    Parimi, Nalini; V. Viswanath; Kashyap, Bina; Patil, Pavan Uday

    2013-01-01

    Aim: The aim of the present study was to determine whether hair could be used as biomarker of fluoride exposure. Materials and Methods: The study was carried out on 30 people living in an endemically fluoridated area and a low fluoridated area. Samples of hair from the occipital were taken and subjected to fluoride analysis by a fluoride ion electrode. Results: Lower fluoride levels in water supplies correlated with lower levels of fluoride in hair and more over higher fluoride levels in wate...

  15. Liquid argon neutrino detectors

    CERN Document Server

    Battistoni, G

    2001-01-01

    The liquid argon imaging technique, as proposed for the ICARUS detector, offers the possibility to perform complementary and simultaneous measurements of neutrinos, as those of CERN to Gran Sasso beam (CNGS) and those from cosmic ray events. For the currently allowed values of the Super-Kamiokande results, the combination of both CNGS and atmospheric data will provide a precise determination of the oscillation parameters. Since one can observe and unambiguously identify nu /sub e/, nu /sub mu / and nu /sub tau / components, this technology allows to explore the full (3*3) mixing matrix. The same class of detector can be proposed for high precision measurements at a neutrino factory. (3 refs).

  16. Isentropic compression of argon

    Energy Technology Data Exchange (ETDEWEB)

    Veeser, L.R.; Ekdahl, C.A.; Oona, H. [and others

    1997-06-01

    The compression was done in an MC-1 flux compression (explosive) generator, in order to study the transition from an insulator to a conductor. Since conductivity signals were observed in all the experiments (except when the probe is removed), both the Teflon and the argon are becoming conductive. The conductivity could not be determined (Teflon insulation properties unknown), but it could be bounded as being {sigma}=1/{rho}{le}8({Omega}cm){sub -1}, because when the Teflon breaks down, the dielectric constant is reduced. The Teflon insulator problem remains, and other ways to better insulate the probe or to measure the conductivity without a probe is being sought.

  17. Fluoride in diet

    Science.gov (United States)

    Diet - fluoride ... bones and teeth. Too much fluoride in the diet is very rare. Rarely, infants who get too ... of essential vitamins is to eat a balanced diet that contains a variety of foods from the ...

  18. Effect of fluoride dentifrices on salivary fluoride levels in children.

    OpenAIRE

    Paul S; Tandon S; Murthy K

    1993-01-01

    Fluoride dentifrices are well accepted for their caries preventive effects. The fluoride concentration in the oral fluids after tooth brushing with fluoride dentifrices may have an important relationship to the caries reducing capacity. The present study was aimed to clinically evaluate the salivary fluoride retention of dentifrices containing low fluoride concentration in 50 children, aged 7-9 years before, during and after the use of fluoride toothpaste. Estimation of fluoride in saliva was...

  19. Fluoride glass fiber optics

    CERN Document Server

    Aggarwal, Ishwar D

    1991-01-01

    Fluoride Glass Fiber Optics reviews the fundamental aspects of fluoride glasses. This book is divided into nine chapters. Chapter 1 discusses the wide range of fluoride glasses with an emphasis on fluorozirconate-based compositions. The structure of simple fluoride systems, such as BaF2 binary glass is elaborated in Chapter 2. The third chapter covers the intrinsic transparency of fluoride glasses from the UV to the IR, with particular emphasis on the multiphonon edge and electronic edge. The next three chapters are devoted to ultra-low loss optical fibers, reviewing methods for purifying and

  20. Depleted argon from underground sources

    Energy Technology Data Exchange (ETDEWEB)

    Back, H.O.; /Princeton U.; Alton, A.; /Augustana U. Coll.; Calaprice, F.; Galbiati, C.; Goretti, A.; /Princeton U.; Kendziora, C.; /Fermilab; Loer, B.; /Princeton U.; Montanari, D.; /Fermilab; Mosteiro, P.; /Princeton U.; Pordes, S.; /Fermilab

    2011-09-01

    Argon is a powerful scintillator and an excellent medium for detection of ionization. Its high discrimination power against minimum ionization tracks, in favor of selection of nuclear recoils, makes it an attractive medium for direct detection of WIMP dark matter. However, cosmogenic {sup 39}Ar contamination in atmospheric argon limits the size of liquid argon dark matter detectors due to pile-up. The cosmic ray shielding by the earth means that Argon from deep underground is depleted in {sup 39}Ar. In Cortez Colorado a CO{sub 2} well has been discovered to contain approximately 500ppm of argon as a contamination in the CO{sub 2}. In order to produce argon for dark matter detectors we first concentrate the argon locally to 3-5% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation. The N{sub 2} and He will be removed by continuous cryogenic distillation in the Cryogenic Distillation Column recently built at Fermilab. In this talk we will discuss the entire extraction and purification process; with emphasis on the recent commissioning and initial performance of the cryogenic distillation column purification.

  1. Fluoride levels and osteosarcoma

    Directory of Open Access Journals (Sweden)

    Simmi Kharb

    2012-01-01

    Full Text Available Context: Osteosarcoma is a rare malignant bone tumor, commonly occurring in the age group of 10 to 24 years. Recent reports have indicated that there is a link between fluoride exposure and osteosarcoma. Aims: The present study was planned to analyze serum levels of fluoride in patients of osteosarcoma and fluoride content of their drinking water. Settings and Design: The present study was carried out comparing 10 patients of osteosarcoma and 10 healthy volunteers (who served as controls. Materials and Methods: Serum and drinking water fluoride levels were estimated by ion selective electrode. Statistical analysis used: The data were computed as mean ± SD and Student′s t test was applied. Results: Both, the serum and drinking water fluoride levels, were significant by higher in patients with osteosarcoma as compared to controls (P < 0.05, P < 0.001, respectively. Conclusions: These results suggest a link between fluoride exposure and osteosarcoma.

  2. Fluoride and Oral Health.

    Science.gov (United States)

    O'Mullane, D M; Baez, R J; Jones, S; Lennon, M A; Petersen, P E; Rugg-Gunn, A J; Whelton, H; Whitford, G M

    2016-06-01

    The discovery during the first half of the 20th century of the link between natural fluoride, adjusted fluoride levels in drinking water and reduced dental caries prevalence proved to be a stimulus for worldwide on-going research into the role of fluoride in improving oral health. Epidemiological studies of fluoridation programmes have confirmed their safety and their effectiveness in controlling dental caries. Major advances in our knowledge of how fluoride impacts the caries process have led to the development, assessment of effectiveness and promotion of other fluoride vehicles including salt, milk, tablets, toothpaste, gels and varnishes. In 1993, the World Health Organization convened an Expert Committee to provide authoritative information on the role of fluorides in the promotion of oral health throughout the world (WHO TRS 846, 1994). This present publication is a revision of the original 1994 document, again using the expertise of researchers from the extensive fields of knowledge required to successfully implement complex interventions such as the use of fluorides to improve dental and oral health. Financial support for research into the development of these new fluoride strategies has come from many sources including government health departments as well as international and national grant agencies. In addition, the unique role which industry has played in the development, formulation, assessment of effectiveness and promotion of the various fluoride vehicles and strategies is noteworthy. This updated version of 'Fluoride and Oral Health' has adopted an evidence-based approach to its commentary on the different fluoride vehicles and strategies and also to its recommendations. In this regard, full account is taken of the many recent systematic reviews published in peer reviewed literature. PMID:27352462

  3. The Liquid Argon Purity Demonstrator

    CERN Document Server

    Adamowski, M; Dvorak, E; Hahn, A; Jaskierny, W; Johnson, C; Jostlein, H; Kendziora, C; Lockwitz, S; Pahlka, B; Plunkett, R; Pordes, S; Rebel, B; Schmitt, R; Stancari, M; Tope, T; Voirin, E; Yang, T

    2014-01-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  4. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  5. Fluoride Rinses, Gels and Foams

    DEFF Research Database (Denmark)

    Twetman, Svante; Keller, Mette K

    2016-01-01

    AIM: The aim of this conference paper was to systematically review the quality of evidence and summarize the findings of clinical trials published after 2002 using fluoride mouth rinses, fluoride gels or foams for the prevention of dental caries. METHODS: Relevant papers were selected after...... (6 on fluoride mouth rinse, 10 on fluoride gel and 3 on fluoride foam); 6 had a low risk of bias while 2 had a moderate risk. All fluoride measures appeared to be beneficial in preventing crown caries and reversing root caries, but the quality of evidence was graded as low for fluoride mouth rinse......, moderate for fluoride gel and very low for acidulated fluoride foam. No conclusions could be drawn on the cost-effectiveness. CONCLUSIONS: This review, covering the recent decade, has further substantiated the evidence for a caries-preventive effect of fluoride mouth rinse, fluoride gel and foam...

  6. PRODUCTION OF THORIUM FLUORIDE

    Science.gov (United States)

    Zachariasen, W.H.

    1959-08-11

    A process is presented for producing anhydrous thorium fluoride comprising the step of contacting a saturated aqueous solution of thorium nitrate with an aqueous solution of hydrofluoric acid having a concentration of about 45 to 50% by weight at a temperature above 70 deg C whereby anhydrous thorium fluoride precipitates.

  7. Fluoride varnishes and enamel caries

    NARCIS (Netherlands)

    Bruyn, Hugo de

    1987-01-01

    Topical fluoride applications have the aim of increasing the fluoride uptake in enamel and consequently reducing caries. In the early ‘60s fluoride varnishes were introduced because they had a long contact period with the enamel which resulted in a higher fluoride uptake than from other topical appl

  8. Fluoride and Water (For Parents)

    Science.gov (United States)

    ... Story" 5 Things to Know About Zika & Pregnancy Fluoride and Water KidsHealth > For Parents > Fluoride and Water Print A ... thirds of 16- to 19-year-olds continue Fluoride and the Water Supply For more than 60 years, water fluoridation ...

  9. Fano factor in pure argon

    International Nuclear Information System (INIS)

    The Fano factor for 5.3 MeV alpha particles in pure argon has been measured with a gridded ionization chamber and estimated to be 0.20 (+0.01-0.02). The obtained value is consistent with the theoretical value if the contribution of elastic nuclear collisions to the Fano factor is taken into the consideration. There is no appreciable difference between the values for pure argon and for a gas mixture of Ar (10%)CH4 obtained in the previous measurement. (orig.)

  10. The cariostatic mechanisms of fluoride

    OpenAIRE

    Kata Rošin-Grget; Kristina Peroš; Ivana Šutej; Krešimir Bašić

    2013-01-01

    This article discusses the possible cariostatic mechanisms of the action of fluoride. In the past, fluoride inhibition of caries was ascribed to reduced solubility of enamel due to incorporation of fluoride (F–) into the enamel minerals. The present evidence from clinical and laboratory studies suggests that the caries-preventive mode of action of fluoride is mainly topical. There is convincing evidence that fluoride has a major effect on demineralisation and remineralisation of dental hard t...

  11. Fluoride toothpastes and fluoride mouthrinses for home use

    Directory of Open Access Journals (Sweden)

    Andrew Rugg-Gunn

    2013-11-01

    Full Text Available Objective. To provide a brief commentary review of fluoride-containing toothpastes and mouthrinses with emphasis on their use at home. Toothpastes and mouthrinses are just two of many ways of providing fluoride for the prevention of dental caries. The first investigations into incorporating fluoride into toothpastes and mouthrinses were reported in the middle 1940s. Unlike water fluoridation (which is ‘automatic fluoridation’, fluoride-containing toothpastes and fluoride-containing mouthrinses are, primarily, for home use and need to be purchased by the individual. By the 1960s, research indicated that fluoride could be successfully incorporated into toothpastes and clinical trials demonstrated their effectiveness. By the end of the 1970s, almost all toothpastes contained fluoride. The widespread use of fluoride-containing toothpastes is thought to be the main reason for much improved oral health in many countries. Of the many fluoride compounds investigated, sodium fluoride, with a compatible abrasive, is the most popular, although amine fluorides are used widely in Europe. The situation is similar for mouthrinses. Concentrations of fluoride (F, commonly found, are 1500 ppm (1500 μg F/g for toothpastes and 225 ppm (225 μg F/ml for mouthrinse. Several systematic reviews have concluded that fluoride-containing toothpastes and mouthrinses are effective, and that there is added benefit from their use with other fluoride delivery methods such as water fluoridation. Guidelines for the appropriate use of fluoride toothpastes and mouthrinses are available in many countries.Conclusion. Fluoride toothpastes and mouthrinses have been developed and extensive testing has demonstrated that they are effective and their use should be encouraged.

  12. Attainable superheat of argon-helium, argon-neon solutions.

    Science.gov (United States)

    Baidakov, Vladimir G; Kaverin, Aleksey M; Andbaeva, Valentina N

    2008-10-16

    The method of lifetime measurement has been used to investigate the kinetics of spontaneous boiling-up of superheated argon-helium and argon-neon solutions. Experiments were made at a pressure of p = 1.5 MPa and concentrations up to 0.33 mol% in the range of nucleation rates from 10 (4) to 10 (8) s (-1) m (-3). The homogeneous nucleation regime has been distinguished. With good agreement between experimental data and homogeneous nucleation theory in temperature and concentration dependences of the nucleation rate, a systematic underestimation by 0.25-0.34 K has been revealed in superheat temperatures over the saturated line attained by experiment as compared with theoretical values calculated in a macroscopic approximation. The revealed disagreement between theory and experiment is connected with the dependence of the properties of new-phase nuclei on their size.

  13. Water Fluoridation Statistics - Percent of PWS population receiving fluoridated water

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2000-2014 Water Fluoridation Statistics is a biennial report of the percentage and number of people receiving fluoridated water from 2000 through 2014, originally...

  14. Binocular indirect argon laser photocoagulator.

    OpenAIRE

    Mizuno, K

    1981-01-01

    The binocular indirect argon laser photocoagulator was newly designed to enable visualisation of the entire fundus during panretinal laser photocoagulation and to treat retinal tears immediately after buckling procedures of the sclera. The lamp housing of the binocular ophthalmoscope was remodelled and adjusted so that the laser beam and illuminating light are coaxial after leaving the ophthalmoscope. The blocking filter was permanently fixed in the eye-pieces to lighten the weight of the oph...

  15. Prediction for new magnetoelectric fluorides

    NARCIS (Netherlands)

    Nenert, G.; Palstra, T. T. M.

    2007-01-01

    We use symmetry considerations in order to predict new magnetoelectric fluorides. In addition to these magnetoelectric properties, we discuss which among these fluorides are the ones susceptible to present multiferroic properties. We emphasize that several materials exhibit ferromagnetic properties.

  16. Liquid Argon Barrel Cryostat Arrived

    CERN Multimedia

    Pailler, P

    Last week the first of three cryostats for the ATLAS liquid argon calorimeter arrived at CERN. It had travelled for 46 days over several thousand kilometers from Japan to CERN. During three years it has been fabricated by Kawasaki Heavy Industries Ltd. at Harima, close to Kobe, under contract from Brookhaven National Laboratory (BNL) of the U.S.. This cryostat consists of two concentric cylinders made of aluminium: the outer vacuum vessel with a diameter of 5.5 m and a length of 7 m, and the inner cold vessel which will contain the electromagnetic barrel calorimeter immersed in liquid argon. The total weight will be 270 tons including the detectors and the liquid argon. The cryostat is now located in building 180 where it will be equipped with 64 feed-throughs which serve for the passage of 122,880 electrical lines which will carry the signals of the calorimeter. After integration of the calorimeter, the solenoidal magnet of ATLAS will be integrated in the vacuum vessel. A final cold test of the cryostat inc...

  17. MOLTEN FLUORIDE NUCLEAR REACTOR FUEL

    Science.gov (United States)

    Barton, C.J.; Grimes, W.R.

    1960-01-01

    Molten-salt reactor fuel compositions consisting of mixtures of fluoride salts are reported. In its broadest form, the composition contains an alkali fluoride such as sodium fluoride, zirconium tetrafluoride, and a uranium fluoride, the latter being the tetrafluoride or trifluoride or a mixture of the two. An outstanding property of these fuel compositions is a high coeffieient of thermal expansion which provides a negative temperature coefficient of reactivity in reactors in which they are used.

  18. Magnetic interactions through fluoride

    DEFF Research Database (Denmark)

    Pedersen, Kasper Steen; Sigrist, Marc; Weihe, Høgni;

    2014-01-01

    The nature of the magnetic interaction through fluoride in a simple, dinuclear manganese(III) complex (1), bridged by a single fluoride ion in a perfectly linear fashion, is established by experiment and density functional theory. The magnitude of the antiferromagnetic exchange interaction...... and the manganese(III) zero-field-splitting parameters are unambiguously determined by inelastic neutron scattering to yield J = 33.0(2) cm(-1) (Ĥ = JŜ1·Ŝ2 Hamiltonian definition) and single-ion D = -4.0(1) cm(-1). Additionally, high-field, high-frequency electron paramagnetic resonance and magnetic measurements...... support the parameter values and resolve |E| ≈ 0.04 cm(-1). The exchange coupling constant (J) is 1 order of magnitude smaller than that found in comparable systems with linear oxide bridging but comparable to typical magnitudes through cyanide, thus underlining the potential of fluoride complexes...

  19. Composing Experimental Environment of PRIDE Argon cell

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Seonho; Jang, Yongkuk; Cho, Il Je [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In PRIDE depleted Uranium feed material and a depleted Uranium mixed with some surrogate material are used for performing engineering scale Pyroprocessing. PRIDE has to maintain inert atmosphere because of the characteristic of Electrolytic Reduction technology, Electro refining technology, Electrowinning technology. The impurity concentration of the Argon cell has to be under 50 ppm(Oxygen, moisture). Atmospheric pressure changes and temperature changes can affect the Argon cell's impurity concentration. In this paper, how to compose the Argon cell impurity concentration under 50 ppm to make the exact optimal experimental environment(Oxygen, moisture) will be introduced. Composing the exact optimal experimental environment by supplying Argon gas have been introduced in this paper. Continuously supplying Argon gas which is heavier than the Oxygen through the bottom of the Argon cell the oxygen eventually discharged through the high vent fan and lower the impurity concentration of Oxygen.

  20. Fluoride retention by kaolin clay

    DEFF Research Database (Denmark)

    Kau, P. M. H.; Smith, D. W.; Binning, Philip John

    1997-01-01

    To evaluate the potential effectiveness of kaolin clay liners in storage of fluoride contaminated waste, an experimental study of the sorption and desorption behaviour of fluoride in kaolin clay was conducted. The degree of fluoride sorption by kaolin was found to depend on solution p......H and available fluoride concentration with equilibrium being achieved within 24 h. A site activation process involving the uptake of fluoride was also observed at the initial stages of sorption. This behaviour was attributed to a layer expansion process of the clay during sorption. The maximum fluoride sorption...... capacity was found to be 18.3 meq/100 g at pH 6 and 8.6 meq/100 g at pH 7. A competitive Langmuir sorption isotherm where sorption is dependant on both pH and fluoride concentration is employed to characterise the experimental sorption and desorption data. The sorption and desorption isotherms revealed...

  1. Other Fluoride Products

    Science.gov (United States)

    ... in preventing tooth decay in people of all ages. Use the information listed below to compare the other fluoride products ... even among children younger than 6 years of age. Proper application technique ... cleared for marketing by the Food and Drug Administration (FDA) as ...

  2. Salt fluoridation and oral health

    Directory of Open Access Journals (Sweden)

    Thomas M. Marthaler

    2013-11-01

    Full Text Available The aim of this paper is to make known the potential of fluoridated salt in community oral health programs, particularly in South Eastern Europe. Since 1922, the addition of iodine to salt has been successful in Switzerland. Goiter is virtually extinct. By 1945, the cariesprotective effect of fluorides was well established. Based on the success of water fluoridation, a gynecologist started adding of fluoride to salt. The sale of fluoridated salt began in 1956 in the Swiss Canton of Zurich, and several other cantons followed suit. Studies initiated in the early seventies showed that fluoride, when added to salt, inhibits dental caries. The addition of fluoride to salt for human consumption was officially authorized in 1980-82. In Switzerland 85% of domestic salt consumed is fluoridated and 67% in Germany. Salt fluoridation schemes are reaching more than one hundred million in Mexico, Colombia, Peru and Cuba. The cost of salt fluoridation is very low, within 0.02 and 0.05 € per year and capita. Children and adults of the low socio-economic strata tend to have substantially more untreated caries than higher strata. Salt fluoridation is by far the cheapest method for improving oral health. Conclusions. Salt fluoridation has cariostatic potential like water fluoridation (caries reductions up to 50%. In Europe, meaningful percentages of users have been attained only in Germany (67% and Switzerland (85%. In Latin America, there are more than 100 million users, and several countries have arrived at coverage of 90 to 99%. Salt fluoridation is by far the cheapest method of caries prevention, and billions of people throughout the world could benefit from this method.

  3. Health Effects Associated with Water Fluoridation.

    Science.gov (United States)

    Richmond, Virginia L.

    1979-01-01

    Discussion is presented concerning fluoridation of water supplies. Correlation between fluoride in drinking water and improved dental health is reviewed. Relationship is expressed between fluoridation and reduced tooth decay. Use of fluoride in treating skeletal disorders is discussed. Author advocates fluoridating water supplies. (SA)

  4. Water fluoridation and oral health

    Directory of Open Access Journals (Sweden)

    Máiréad Antoinette Harding

    2013-11-01

    Full Text Available Water fluoridation, is the controlled addition of fluoride to the water supply, with the aim of reducing the prevalence of dental caries. Current estimates suggest that approximately 370 million people in 27 countries consume fluoridated water, with an additional 50 million consuming water in which fluoride is naturally occurring. A pre-eruptive effect of fluoride exists in reducing caries levels in pit and fissure surfaces of permanent teeth and fluoride concentrated in plaque and saliva inhibits the demineralisation of sound enamel and enhances the remineralisation of demineralised enamel. A large number of studies conducted worldwide demonstrate the effectiveness of water fluoridation. Objections to water fluoridation have been raised since its inception and centre mainly on safety and autonomy. Systematic reviews of the safety and efficacy of water fluoridation attest to its safety and efficacy; dental fluorosis identified as the only adverse outcome. Conclusion: Water fluoridation is an effective safe means of preventing dental caries, reaching all populations, irrespective of the presence of other dental services. Regular monitoring of dental caries and fluorosis is essential particularly with the lifelong challenge which dental caries presents.

  5. Magnesium fluoride recovery method

    Science.gov (United States)

    Gay, Richard L.; McKenzie, Donald E.

    1989-01-01

    A method of obtaining magnesium fluoride substantially free from radioactive uranium from a slag containing the same and having a radioactivity level of at least about 7000 pCi/gm. The slag is ground to a particle size of about 200 microns or less. The ground slag is contacted with an acid under certain prescribed conditions to produce a liquid product and a particulate solid product. The particulate solid product is separated from the liquid and treated at least two more times with acid to produce a solid residue consisting essentially of magnesium fluoride substantially free of uranium and having a residual radioactivity level of less than about 1000 pCi/gm. In accordance with a particularly preferred embodiment of the invention a catalyst and an oxidizing agent are used during the acid treatment and preferably the acid is sulfuric acid having a strength of about 1.0 Normal.

  6. Fluoride in dental erosion

    OpenAIRE

    Magalhães, A C; Wiegand, A.; Rios, D.; Buzalaf, M.A.R.; Lussi, A.

    2011-01-01

    Dental erosion develops through chronic exposure to extrinsic/intrinsic acids with a low pH. Enamel erosion is characterized by a centripetal dissolution leaving a small demineralized zone behind. In contrast, erosive demineralization in dentin is more complex as the acid-induced mineral dissolution leads to the exposure of collagenous organic matrix, which hampers ion diffusion and, thus, reduces further progression of the lesion. Topical fluoridation inducing the formation of a protective l...

  7. Transition probabilities for argon I

    International Nuclear Information System (INIS)

    Transition probabilities for ArI lines have been calculated on the basis of the (j,k)-coupling scheme for more than 16000 spectral lines belonging to the transition arrays 4s-np (n=4 to n=9), 5s-np (n=5 to n=9), 6s-np (n=6 to n=9), 7s-np (n=8 to n=9), 4p-ns (n=5 to n=10), 5p-ns (n=6 to n=9), 6p-ns (n=7 to n=8), 4p-nd (n=3 to n=9), 5p-nd (n=4 to n=9), 3d-np (n=5 to n=9), 4d-np (n=6 to n=9), 5d-np (n=7 to n=9), 3d-nf (n=4 to n=9), 4d-nf (n=4 to n=9), 5d-nf (n=5 to n=9), 4f-nd (n=5 to n=9) 5f-nd (n=6 to n=9), 4f-ng (n=5 to n=9), 5f-ng (n=6 to n=9). Inso far as values by other authors exist, comparison is made with these values. It turns out that the results obtained in (j,k)-coupling are close to those obtained in intermediate coupling except for intercombination lines. For high principal and/or orbital quantum numbers the transition probabilities for a multiplet approach those of the corresponding transitions in atomic hydrogen. The calculated values are applied to construct a simplified argon-atom model, which reflects the real transition properties and which allows simplified but realistic non-equilibrium calculations for argon plasmas which deviate from local thermodynamic equilibrium (LTE)

  8. Private Well Water and Fluoride

    Science.gov (United States)

    ... it is the responsibility of the homeowner to know and understand the quality of the water from their well. The U.S. ... or area. Additional information on testing well water quality in private wells ... do I need to know about fluoride and groundwater from a well? Fluoride ...

  9. Prediction for new magnetoelectric fluorides

    OpenAIRE

    Nenert, G.; Palstra, T. T. M.

    2007-01-01

    We use symmetry considerations in order to predict new magnetoelectric fluorides. In addition to these magnetoelectric properties, we discuss which among these fluorides are the ones susceptible to present multiferroic properties. We emphasize that several materials exhibit ferromagnetic properties. This ferromagnetism should enhance the interplay between the magnetic and dielectric properties in these materials.

  10. WET FLUORIDE SEPARATION METHOD

    Science.gov (United States)

    Seaborg, G.T.; Gofman, J.W.; Stoughton, R.W.

    1958-11-25

    The separation of U/sup 233/ from thorium, protactinium, and fission products present in neutron-irradiated thorium is accomplished by dissolving the irradiated materials in aqueous nitric acid, adding either a soluble fluoride, iodate, phosphate, or oxalate to precipltate the thorium, separating the precipltate from the solution, and then precipitating uranlum and protactinium by alkalizing the solution. The uranium and protactinium precipitate is removcd from the solution and dissolved in nitric acid. The uranyl nitrate may then be extracted from the acid solution by means of ether, and the protactinium recovered from the aqueous phase.

  11. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  12. Status and perspecitves of liquid argon calorimeters

    International Nuclear Information System (INIS)

    The status of liquid argon calorimeters is reviewed, and experience obtained with these devices is described. Future perspectives of the liquid ionization chamber technique in calorimetry are also discussed. (orig.)

  13. Clinical periodontics with the argon laser

    Science.gov (United States)

    Finkbeiner, R. L.

    1995-04-01

    The argon laser has proven to be a valuable tool for the thermodynamic debridement of the periodontal lesion, incisions and tissue fusion. Illustrations of clinical applications and discussion of laser parameters will be provided.

  14. Argon plasma irradiation of polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Slepicka, P., E-mail: petr.slepicka@vscht.c [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic); Vasina, A. [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic); Kolska, Z. [J.E. Purkyne University, Department of Chemistry, 40096 Usti Nad Labem (Czech Republic); Luxbacher, T. [Anton Paar GmbH, 8054 Graz (Austria); Malinsky, P.; Mackova, A. [Nuclear Physics Institute of Academy of Sciences of the Czech Republic, 25068 Rez (Czech Republic); Svorcik, V. [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic)

    2010-06-15

    Polypropylene samples were exposed to argon plasma discharge and the changes of the PP surface properties were studied by different methods. Surface wettability was derived from contact angle measured by standard goniometry and chemical structure of the plasma modified PP was studied using X-ray photoelectron spectroscopy (XPS) and by Rutherford backscattering spectroscopy (RBS), surface morphology and roughness of samples using AFM. Zeta potential of pristine and modified PP was determined with the SurPASS. The presence of incorporated oxygen in the PP surface layer, about 60 nm thick, was observed in RBS spectra. Oxygen concentration is a decreasing function of the depth. With progressing aging time the oxygen concentration on the PP surface decreases. Plasma treatment results in a rapid decrease of the contact angle, which increases again with increasing aging time. In XPS measurement the oxygen containing structures, created by the plasma treatment, were found on the very surface of the modified PP and the zeta potential being changed too. The significant difference in zeta potential between pristine and plasma treated PP clearly indicates that the plasma treatment leads to a more hydrophilic PP surface.

  15. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  16. Measurements on scintillation light from liquid argon

    International Nuclear Information System (INIS)

    It is shown that an argon calorimeter can operate as a scintillation detector, provided that xenon is added. With the addition of 170 ppm xenon a light yield of 70% has been obtained. In addition the light yield is determined under influence of an electric field, from differently ionising particles and by the use of aluminium mirrors acting as light guides. Finally first measurements with a photomultiplier working at liquid argon temperatures are reported. (orig.)

  17. Argon Laser Photoablation for Postburn Conjunctival Pigmentation

    Directory of Open Access Journals (Sweden)

    Seong Joon Ahn

    2014-01-01

    Full Text Available We report a case of an ocular burn injury from boiling water which resulted in conjunctival pigmentation, 1 week following injury. For cosmetic purposes, 2 sessions of argon laser photoablation were performed. One month after laser treatment, conjunctival pigmentation had been successfully removed and the patient was very satisfied with the results. Argon laser photoablation may be an effective way to remove postburn conjunctival pigmentation.

  18. Argon clusters embedded in helium nanodroplets.

    Science.gov (United States)

    da Silva, Filipe Ferreira; Bartl, Peter; Denifl, Stephan; Echt, Olof; Märk, Tilmann D; Scheier, Paul

    2009-11-14

    Electron impact ionization of argon clusters embedded in helium droplets is investigated. Superior mass resolution makes it possible to distinguish between nominally isobaric cluster ions. An abundance maximum for ArHe(12)(+) is unambiguously confirmed; the spectra also prove the formation of Ar(2)He(n)(+) complexes that had been claimed to fragment into pure Ar(2)(+). Distributions of larger argon cluster ions containing up to 60 atoms closely resemble distributions observed upon electron impact or photoionization of bare argon clusters; caging and evaporative cooling provided by the helium matrix do not suffice to quench fragmentation of the nascent argon cluster ions. Intriguing abundance anomalies are observed in distributions of argon cluster ions that contain water, nitrogen or oxygen impurities. The strong abundance of Ar(55)H(2)O(+), Ar(54)O(2)(+) and Ar(54)N(2)(+) contrasts with the virtual absence of slightly larger cluster ions containing the corresponding impurities. The features are probably related to enhanced cluster ion stability upon closure of the second icosahedral shell but the difference in magic numbers (54 versus 55) and the well-known reactivity of charged argon-nitrogen complexes suggest structural differences. PMID:19851558

  19. Urinary Fluoride Concentration in Children with Disabilities Following Long-Term Fluoride Tablet Ingestion

    Science.gov (United States)

    Liu, Hsiu-Yueh; Chen, Jung-Ren; Hung, Hsin-Chia; Hsiao, Szu-Yu; Huang, Shun-Te; Chen, Hong-Sen

    2011-01-01

    Urine is the most commonly utilized biomarker for fluoride excretion in public health and epidemiological studies. Approximately 30-50% of fluoride is excreted from urine in children. Urinary fluoride excretion reflects the total fluoride intake from multiple sources. After administering fluoride tablets to children with disabilities, urinary…

  20. 49 CFR 173.163 - Hydrogen fluoride.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Hydrogen fluoride. 173.163 Section 173.163... Hydrogen fluoride. (a) Hydrogen fluoride (hydrofluoric acid, anhydrous) must be packaged as follows: (1) In... filling ratio of 0.84. (b) A cylinder removed from hydrogen fluoride service must be condemned...

  1. Potassium-argon/argon-40-argon-39 geochronology of Cenozoic alkali basalts from the South China Sea

    Institute of Scientific and Technical Information of China (English)

    YAN Quanshu; SHI Xuefa; YANG Yaomin; WANG Kunshan

    2008-01-01

    Based on the isotopic chronologic results of Cenozoic alkali basalts from the South China Sea,the characteristics of volcanic activi-ty of the South China Sea after spreading were studied.The potassium - argon ages of eight alkali basalt samples from the South China Sea,and the argon - argon ages of two samples among them are reported.Apparent ages of the whole rock are 3.80 to 7.91 Ma with an average value of 5.43 Ma (potassium- argon,whole rock),and there is little difference among samples at the same location,e.g.,4.76~5.78 Ma for location S04-12.The argon - argon ages for the two samples are 6.06 and 4.71 Ma,which lie within the age scope of potassium - argon method.The dating results indicate that rock-forming age is from late Miocene to Pli-ocene,which is consistent with erupting event for alkali basalts from adjacent regions of the South China Sea.Volcanic activities occur after the cessation of spreading of the South China Sea,which are controlled by lithospheric fault and the spreading center formed during the spreading period of the South China Sea.These dating results,combined with geochemical characteristics of these basalts,the published chronological data for the South China Sea and its adjacent regions,and the updated geophysical data near Hainan Island,suggest that after the cessation of spreading of the South China Sea,there occur widely distributing magmatic activities which primarily is alkali basalt,and the volcanic activity continues to Quaternary.The activity may be relative to Hainan mantle plume originated from core/mantle boundary.

  2. Corrosion behavior of Hastelloy-N alloys in molten salt fluoride in Ar gas or in air

    International Nuclear Information System (INIS)

    The effects of air on the corrosion of Hastelloy-N alloys in molten salt coolant containing fission product elements were investigated to determine the safety of structural materials in high-temperature reactors cooled with fluoride salt. Corrosion tests of Hastelloy-N in the molten fluoride salt FLiNaK in an alumina crucible and a graphite crucible under argon gas or air were performed at 773–923 K for 100 h. The depth of corrosive attack, as well as the extent of chromium and molybdenum depletion, increased with increasing temperature. The extent of Hastelloy-N corrosion in molten salt under air was significantly greater than under argon gas. The effect of adding the impurity cesium iodide to molten salt containing nuclear waste fuel on the corrosion behavior was negligible. (author)

  3. Molten fluoride fuel salt chemistry

    International Nuclear Information System (INIS)

    The chemistry of molten fluorides is traced from their development as fuels in the Molten Salt Reactor Experiment with important factors in their selection being discussed. Key chemical characteristics such as solubility, redox behavior, and chemical activity are explained as they relate to the behavior of molten fluoride fuel systems. Fission product behavior is described along with processing experience. Development requirements for fitting the current state of the chemistry to modern nuclear fuel system are described. It is concluded that while much is known about molten fluoride behavior, processing and recycle of the fuel components is a necessary factor if future systems are to be established

  4. Argon Collection And Purification For Proliferation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Achey, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event was a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.

  5. Attenuation of vacuum ultraviolet light in liquid argon

    CERN Document Server

    Neumeier, A; Oberauer, L; Potzel, W; Schönert, S; Dandl, T; Heindl, T; Ulrich, A; Wieser, J

    2015-01-01

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  6. Fluoride glass: Crystallization, surface tension

    Science.gov (United States)

    Doremus, R. H.

    1988-01-01

    Fluoride glass was levitated acoustically in the ACES apparatus on STS-11, and the recovered sample had a different microstructure from samples cooled in a container. Further experiments on levitated samples of fluoride glass are proposed. These include nucleation, crystallization, melting observations, measurement of surface tension of molten glass, and observation of bubbles in the glass. Ground experiments are required on sample preparation, outgassing, and surface reactions. The results should help in the development and evaluation of containerless processing, especially of glass, in the development of a contaminent-free method of measuring surface tensions of melts, in extending knowledge of gas and bubble behavior in fluoride glasses, and in increasing insight into the processing and properties of fluoride glasses.

  7. Fluoride-conversion synthesis of homogeneous actinide oxide solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Silva, G W Chinthaka M [ORNL; Hunn, John D [ORNL; Yeamans, Charles B. [University of California, Berkeley; Cerefice, Gary S. [University of Nevada, Las Vegas; Czerwinski, Ken R. [University of Nevada, Las Vegas

    2011-01-01

    Here, a novel route to synthesize (U, Th)O2 solid solutions at a relatively low temperature of 1100 C is demonstrated. First, the separate actinide oxides reacted with ammonium bifluoride to form ammonium actinide fluorides at room temperature. Subsequently, this mixture was converted to the actinide oxide solid solution using a two-phased heat treatment, first at 610 C in static air, then at 1100 C in flowing argon. Solid solutions obeying Vegard s Law were synthesized for ThO2 content from 10 to 90 wt%. Microscopy showed that the (U, Th)O2 solid solutions synthesized with this method to have considerably high crystallinity and homogeneity, suggesting the suitability of material thus synthesized for sintering into nuclear fuel pellets at low temperatures.

  8. Method of aluminium fluoride manufacture

    International Nuclear Information System (INIS)

    The manufacture of aluminium fluoride is based on waste processing in uranium hexafluoride conversion to uranium oxides within the fuel cycle. The conversion is the stoichiometric conversion of uranium hexafluoride with aluminium nitrate to uranyl nitrate. This is extracted from the water phase by phosphoric acid trialkyl ester to an organic solvent and further processed. The discharge water phase is solidified by evaporation to solid aluminium fluoride and nitric acid. (M.S.)

  9. FLUORIDE TOXICITY – A HARSH REALITY

    Directory of Open Access Journals (Sweden)

    Bandlapalli Pavani

    2011-04-01

    Full Text Available There are many incidents of fluoride toxicity whether it is acute or chronic. Fluoride toxicity is an environmental hazard which arises from the upper layers of geological crust and is dissolved in water. Prolonged drinking of such water causes chronic fluoride toxicity. Use of fluoride containing compounds for various purposes such as dental products, metal, glass, refrigerator and chemical industries act as a source of fluoride poisoning and increase the risk of toxicity. This review reflects the deleterious effects of fluorides on various organs in the physiological system.

  10. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    International Nuclear Information System (INIS)

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field

  11. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    CERN Document Server

    Creus, W; Amsler, C; Ferella, A D; Rochet, J; Scotto-Lavina, L; Walter, M

    2015-01-01

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.

  12. Contraction ionization waves in the argon contracted discharge

    International Nuclear Information System (INIS)

    An investigation of ionization waves in the argon contracted discharge and a definition of their arising propagation mechanism accounting for the specificity of elementary pocesses characteristic of argon are presented. (author)

  13. Industrial fluoride pollution. Chronic fluoride poisoning in Cornwall Island cattle.

    Science.gov (United States)

    Krook, L; Maylin, G A

    1979-04-01

    An aluminum plant on the south bank of the St. Lawrence river, southwest of Cornwall Island, Ontario, Canada, has emitted 0.816 metric tons of fluoride daily since 1973; considerably higher amounts were emitted from 1959 to 1973. The plant has been designated as the "major source of fluoride emissions impacting on Cornwall Island." Chronic fluoride poisoning in Cornwall island cattle was manifested clinically by stunted growth and dental fluorosis to a degree of severe interference with drinking and mastication. Cows died at or were slaughtered after the third pregnancy. The deterioration of cows did not allow further pregnancies. Fluoride concentrations in ash of biopsied coccygeal vertebrae increased significantly with age and were dependent on distance from and direction to the aluminum plant. Fluoride in bone ash of a 7-month old-fetus exceeded 500 ppm; fluoride thus was passed transplacentally. Analyses of fluoride in ash of bones obtained at necropsy of cattle from 4 months of age to 4 to 5 years of age showed increased amounts with age. Cancellous bone retained far higher amounts than cortical bone, a reflection of the normally higher metabolic rate of cancellous bone. Concentrations exceeding 10,000 ppm fluoride were recorded in cancellous bone of a 4-to 5-year-old cow. The target cells for fluoride in chronic fluorosis were shown to be the ameloblasts, the dental pulp cells and the odontoblasts and, in bone, primarily the resorbing osteocytes and also the osteoblasts. Atrophy and necrosis of the ameloblasts were responsible for enamel defects. The existing enamel showed brown discoloration from fluoride deposits. The pulp cells underwent fibrous and osseous metaplasia and necrosis of the ectopic bone occurred. The odontoblasts were atrophic and the dentin showed brown discoloration. The resorbing osteocytes were inactive and osteosclerosis resulted. This was especially pronounced in areas of normally great apposition, i.e. in the metaphyses. The epiphyseal

  14. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  15. Antiapoptotic activity of argon and xenon.

    Science.gov (United States)

    Spaggiari, Sabrina; Kepp, Oliver; Rello-Varona, Santiago; Chaba, Kariman; Adjemian, Sandy; Pype, Jan; Galluzzi, Lorenzo; Lemaire, Marc; Kroemer, Guido

    2013-08-15

    Although chemically non-reactive, inert noble gases may influence multiple physiological and pathological processes via hitherto uncharacterized physical effects. Here we report a cell-based detection system for assessing the effects of pre-defined gas mixtures on the induction of apoptotic cell death. In this setting, the conventional atmosphere for cell culture was substituted with gas combinations, including the same amount of oxygen (20%) and carbon dioxide (5%) but 75% helium, neon, argon, krypton, or xenon instead of nitrogen. The replacement of nitrogen with noble gases per se had no effects on the viability of cultured human osteosarcoma cells in vitro. Conversely, argon and xenon (but not helium, neon, and krypton) significantly limited cell loss induced by the broad-spectrum tyrosine kinase inhibitor staurosporine, the DNA-damaging agent mitoxantrone and several mitochondrial toxins. Such cytoprotective effects were coupled to the maintenance of mitochondrial integrity, as demonstrated by means of a mitochondrial transmembrane potential-sensitive dye and by assessing the release of cytochrome c into the cytosol. In line with this notion, argon and xenon inhibited the apoptotic activation of caspase-3, as determined by immunofluorescence microscopy coupled to automated image analysis. The antiapoptotic activity of argon and xenon may explain their clinically relevant cytoprotective effects. PMID:23907115

  16. Fluoride level in saliva after bonding orthodontic brackets with a fluoride containing adhesive

    NARCIS (Netherlands)

    Ogaard, B; Arends, J; Helseth, H; Dijkman, G; vanderKuijl, M

    1997-01-01

    The fluoride level in saliva is considered an important parameter in caries prevention. Elevation of the salivary fluoride level by a fluoride-releasing orthodontic bonding adhesive would most likely be beneficial in the prevention of enamel caries. In this study, the fluoride level in saliva was me

  17. Keeping argon under a graphene lid-Argon intercalation between graphene and nickel(111)

    Science.gov (United States)

    Späth, Florian; Gotterbarm, Karin; Amende, Max; Bauer, Udo; Gleichweit, Christoph; Höfert, Oliver; Steinrück, Hans-Peter; Papp, Christian

    2016-01-01

    We report on the intercalation of graphene grown on a Ni(111) crystal with argon. Argon is implanted in the Ni(111) crystal by ion bombardment before graphene growth, and diffuses to the surface during the growth of graphene at elevated temperatures. Graphene acts as an atomically thin barrier and keeps the argon underneath. We investigated this system with high resolution X-ray photoelectron spectroscopy. From our experiments we determined the mean quantities of argon under graphene. From our analysis, a simple model to determine the pressure under the graphene layer is presented. In our measurements, we find an increased thermal stability of the intercalated graphene as compared to non-intercalated graphene on Ni(111).

  18. Fluoridering af drikkevandet i Danmark?

    DEFF Research Database (Denmark)

    Arvin, Erik; Spliid, Henrik; Bruvo, M.;

    2010-01-01

    Første gang sammenhængen mellem caries (huller i tænderne) og fluoridindholdet i drikkevand blev diskuteret i vandværkskredse i Danmark var ved årsmødet i 1958. Her blev det oplyst, at fluorid i drikkevand beskytter mod caries, men man konstaterede også, at der nok ikke var stemning for fluorid......-tilsætning til drikkevandet (fluoridering). Siden da er emnet ikke taget op. Formålet med dette indlæg er at besvare spørgsmålene: 1. Er der behov for fluoridering af drikkevandet i Danmark? 2. Er der alternativer? Hvordan påvirker blødgøring af vand og andre vandbehandlingsmetoder dental caries hos børn og unge......? Som baggrund herfor vil vi redegøre for resultaterne af et netop afsluttet studium af sammenhængen mellem caries og drikkevandets sammensætning, specielt m.h.t. luoridindholdet og vandets calciumindhold (hårdhed). Undersøgelsen bekræfter, at fluorid i drikkevand i væsentlig grad beskytter mod caries...

  19. Argon Laser Treatment of Strawberry Hemangioma in Infancy

    OpenAIRE

    Achauer, Bruce M.; Vander Kam, Victoria M.

    1985-01-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results.

  20. Argon laser treatment of strawberry hemangioma in infancy.

    Science.gov (United States)

    Achauer, B M; Vander Kam, V M

    1985-11-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results. PMID:4082569

  1. Acute toxicity of uranium hexafluoride, uranyl fluoride and hydrogen fluoride

    International Nuclear Information System (INIS)

    Uranium hexafluoride (UF6) released into the atmosphere will react rapidly with moisture in the air to form the hydrolysis products uranyl fluoride (UO2F2) and hydrogen fluoride (HF). Uranium compounds such as UF6 and UO2F2 exhibit both chemical toxicity and radiological effects, while HF exhibits only chemical toxicity. This paper describes the development of a methodology for assessing the human health consequences of a known acute exposure to a mixture of UF6, UO2F2, and HF. 4 refs., 2 figs., 5 tabs

  2. High-fluoride groundwater.

    Science.gov (United States)

    Rao, N Subba

    2011-05-01

    Fluoride (F(-)) is essential for normal bone growth, but its higher concentration in the drinking water poses great health problems and fluorosis is common in many parts of India. The present paper deals with the aim of establishment of facts of the chemical characteristics responsible for the higher concentration of F(-) in the groundwater, after understanding the chemical behavior of F(-) in relation to pH, total alkalinity (TA), total hardness (TH), carbonate hardness (CH), non-carbonate hardness (NCH), and excess alkalinity (EA) in the groundwater observed from the known areas of endemic fluorosis zones of Andhra Pradesh that have abundant sources of F(-)-bearing minerals of the Precambrians. The chemical data of the groundwater shows that the pH increases with increase F(-); the concentration of TH is more than the concentration of TA at low F(-) groundwater, the resulting water is represented by NCH; the TH has less concentration compared to TA at high F(-) groundwater, causing the water that is characterized by EA; and the water of both low and high concentrations of F(-) has CH. As a result, the F(-) has a positive relation with pH and TA, and a negative relation with TH. The operating mechanism derived from these observations is that the F(-) is released from the source into the groundwater by geochemical reactions and that the groundwater in its flowpath is subjected to evapotranspiration due to the influence of dry climate, which accelerates a precipitation of CaCO(3) and a reduction of TH, and thereby a dissolution of F(-). Furthermore, the EA in the water activates the alkalinity in the areas of alkaline soils, leading to enrichment of F(-). Therefore, the alkaline condition, with high pH and EA, and low TH, is a more conducive environment for the higher concentration of F(-) in the groundwater.

  3. Fluoride: its role in dentistry

    Directory of Open Access Journals (Sweden)

    Livia Maria Andaló Tenuta

    2010-01-01

    Full Text Available In spite of decades of research on fluoride and the recognition of its role as the cornerstone of dental caries reduction in the last fifty years, questions still arise on its use at community, self-applied and professional application levels. Which method of fluoride delivery should be used? How and when should it be used? How can its benefits be maximized and still reduce the risks associated with its use? These are only some of the challenging questions facing us daily. The aim of this paper is to present scientific background to understand the importance of each method of fluoride use considering the current caries epidemiological scenario, and to discuss how individual or combined methods can be used based on the best evidence available.

  4. Molten fluorides for nuclear applications

    Directory of Open Access Journals (Sweden)

    Sylvie. Delpech

    2010-12-01

    Full Text Available The importance of pyrochemistry is being increasingly acknowledged and becomes unavoidable in the nuclear field. Molten salts may be used for fuel processing and spent fuel recycling, for heat transfer, as a homogeneous fuel and as a breeder material in fusion systems. Fluorides that are stable at high temperature and under high neutron flux are especially promising. Analysis of several field cases reveals that corrosion in molten fluorides is essentially due to the oxidation of metals by uranium fluoride and/or oxidizing impurities. The thermodynamics of this process are discussed with an emphasis on understanding the mass transfer in the systems, selecting appropriate metallic materials and designing effective purification methods.

  5. Fluoride in African groundwater: Occurrence and mitigation

    NARCIS (Netherlands)

    Vasak, S.; Griffioen, J.; Feenstra, L.

    2010-01-01

    Fluoride in groundwater has both natural and anthropogenic sources. Fluoride bearing minerals, volcanic gases and various industrial and agricultural activities can contribute to high concentrations. High intake of fluoride from drinking water is the main cause of fluorosis and may lead to many othe

  6. The comparison of calculated transition probabilities with luminescence characteristics of erbium(III) in fluoride glasses and in the mixed yttrium-zirconium oxide crystal

    Science.gov (United States)

    Reisfeld, R.; Katz, G.; Jacoboni, C.; De Pape, R.; Drexhage, M. G.; Brown, R. N.; Jørgensen, C. K.

    1983-07-01

    Fluorozirconate glasses containing 2 mole% ErF 3 were prepared by melting the binary fluorides with ammonium bifluoride under an atmosphere of carbon tetrachloride and argon at 850°C. Absorption spectra of these glasses were obtained and the Judd-Ofelt parameters were calculated. Emission spectra and lifetimes of erbium in fluorozirconate glass, in lead-gallium-zinc fluoride glass, and in yttrium-zirconium oxide crystal were measured and compared with the theoretical calculations. Laser emission lines in these materials are deduced from these measurements. It is suggested that materials doped with erbium may serve as light sources for fiber optic waveguides made from the undoped materials.

  7. METHOD OF PREPARING METAL FLUORIDES

    Science.gov (United States)

    Katz, J.J.; Sheft, I.

    1959-08-11

    A method is presented for preparing the halides of elements which are relatively non-reactive with halogenating agents. The method involves reacting a mixture of an oxygen containing salt of a difficulty halogenated metal with an oxygen containing salt of an easily halogenated metal with a halogenating agent. Accordingly plutonium tetrafluoride is produced by reacting a mixture of plutonium dioxide and uranium octaoxide with bromine trifluoride. The reaction proceeds smoothly at moderate temperatures and the resulting plutonium trifluoride may be readily separated from many impurities which form volatile fluorides by volatilizing these volatile fluorides from the reaction chamber.

  8. Flow Parameters of Argon plasma Discharge

    International Nuclear Information System (INIS)

    Owing to the viscosity, the plasma will be adhering to the inner surface of the outer electrode and outer surface of the inner one. As result that the discharge will be eroding the walls of coaxial system. The thickness of the boundary layer near the walls has been estimated at different positions from the breech of coaxial plasma gun. It is found that the thickness of layer 0.008 cm at the end of inner electrode (17 cm). A coaxial plasma gun device is operated in argon gas at ambient pressure 0.6 Torr and discharge voltage about 10 KV. The electron temperature of argon discharge has been determined by using spectroscopic technique. It is found that kTe=3.4 eV. By knowing the thickness of the boundary layer, the density can be determined. The Reynolds number R=105 and Mach number M=5 i.e. the flow is compressible and hypersonic

  9. Argon laser irradiation of the otolithic organ

    Energy Technology Data Exchange (ETDEWEB)

    Okuno, T.; Nomura, Y.; Young, Y.H.; Hara, M. (Univ. of Tokyo (Japan))

    1990-12-01

    An argon laser was used to irradiate the otolithic organs of guinea pigs and cynomolgus monkeys. After stapedectomy, the argon laser (1.5 W x 0.5 sec/shot) irradiated the utricle or saccule without touching the sensory organs. The stapes was replaced over the oval window after irradiation. The animals used for acute observation were killed immediately for morphologic studies; those used for long-term observation were kept alive for 2, 4, or 10 weeks. Acute observation revealed that sensory and supporting cells were elevated from the basement membrane only in the irradiated area. No rupture of the membranous labyrinth was observed. Long-term observation revealed that the otolith of the macula utriculi had disappeared in 2-week specimens. The entire macula utricili had disappeared in 10-week specimens. No morphologic changes were observed in cochlea, semicircular canals, or membranous labyrinth. The saccule showed similar changes.

  10. Abnormal epidermal changes after argon laser treatment

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, R.A.; Knobler, R.M.; Aberer, E.; Klein, W.; Kocsis, F.; Ott, E. (Univ. of Vienna (Austria))

    1991-02-01

    A 26-year-old woman with a congenital port-wine stain on the forehead was treated three times at 2-month intervals with an argon laser. Six months after the last treatment, moderate blanching and mild scaling confined to the treated area was observed. A biopsy specimen of the treated area revealed a significant decrease in ectatic vessels. However, epidermal changes similar to those of actinic keratosis with disorganized cell layers and marked cytologic abnormalities were seen. Analysis of peripheral blood lymphocytes for a defect in DNA repair was negative. Multiple, argon laser-induced photothermal effects may be responsible for the changes observed in our case and may lead to premalignant epidermal transformation.

  11. Explanation of the memory effect in argon

    Directory of Open Access Journals (Sweden)

    Marković Vidosav

    2005-01-01

    Full Text Available Memory effect - the long time variation of the electrical breakdown time delay on the relaxation time td (τ was observed in argon 24 hours after relaxation times and explained by the long-lived metastable states remaining from the preceding glow. However, the quenching processes reducing the effective lifetime of metastable states several orders of magnitude below that relevant for the time scale of observation were neglected. By applying approximate gas phase models it was found that the early afterglow kinetics up to hundreds of milliseconds is dominated by the decay of molecular argon ions Ar2+ and the approximate value of their ambipolar diffusion coefficient is determined. After that, nitrogen atoms present as impurities and recombined on the cathode surface and/or field emission determine the breakdown time delay down to the cosmic rays and natural radioactivity level.

  12. Fluoride remediation using floating macrophytes

    Directory of Open Access Journals (Sweden)

    Naba Kumar Mondal

    2014-04-01

    Full Text Available Six aquatic macrophytes, such as Pistia stratiotes, Ceratophyllum demersum, Nymphoides indica, Lemna major, Azolla pinnata,and Eichhornia crassipes were considered for remove fluoride from aqueous solution. Five different concentrations (10, 30, 50, and 100 ppm of fluoride solution were taken in 1 L plastic container. Fixed weight (20 g of macrophytes along with 500 ml fluoride solution was taken in each plastic container for 72 hours observation. Results demonstrated all the macrophytes show highest fluoride removal during 24 h to 48 h, but after 72 h their efficiency reduced drastically. The species N. indica showed better removal efficiency than other experimental macrophytes. In general, pigment measurement data indicated higher concentration at 72 h. However, Pistia sp. showed higher concentration of pigmentation at intermediate time interval (48 h. Higher level of dry weight to fresh weight ratio was recorded for L. major and A. pinnata at all concentrations, excepting at 10 ppm. In addition, all macrophytes showed lower RGR at higher concentration. Isotherm study indicated that macrophyte C. demersum is a good fitted with Freundlich and Langmuir isotherm whereas L. major with Langmuir isotherm during 24 hours.

  13. Special Report: Fluoridation of Water.

    Science.gov (United States)

    Hileman, Bette

    1988-01-01

    Reviews the controversy regarding water fluoridation in the United States during the last 50 years. Discusses the current status; benefits; and health risks including skeletal fluorosis, kidney disease, hypersensitivity, mutagenic effects, birth defects, and cancer. Presents statistics and anecdotal accounts. (CW)

  14. Anatomy of an Inversion - Argon Isotopes

    Science.gov (United States)

    Zamick, L.; Sharon, Y. Y.; Robinson, S. J. Q.

    2012-02-01

    Two different interactions give similar results for excitation energies and g factors of 2+1 states for most even-even argon isotopes except 46Ar. This is explained in terms of an inversion in J = ½+ and levels in 47K which is successfully obtained by one of the interactions but not the other. This example shows the possible dangers of nuclear astrophysics extrapolations.

  15. Alimentary fluoride intake in preschool children

    Directory of Open Access Journals (Sweden)

    Lencova Erika

    2011-10-01

    Full Text Available Abstract Background The knowledge of background alimentary fluoride intake in preschool children is of utmost importance for introducing optimal and safe caries preventive measures for both individuals and communities. The aim of this study was to assess the daily fluoride intake analyzing duplicate samples of food and beverages. An attempt was made to calculate the daily intake of fluoride from food and swallowed toothpaste. Methods Daily alimentary fluoride intake was measured in a group of 36 children with an average age of 4.75 years and an average weight of 20.69 kg at baseline, by means of a double plate method. This was repeated after six months. Parents recorded their child's diet over 24 hours and collected duplicated portions of food and beverages received by children during this period. Pooled samples of food and beverages were weighed and solid food samples were homogenized. Fluoride was quantitatively extracted from solid food samples by a microdiffusion method using hexadecyldisiloxane and perchloric acid. The content of fluoride extracted from solid food samples, as well as fluoride in beverages, was measured potentiometrically by means of a fluoride ion selective electrode. Results Average daily fluoride intake at baseline was 0.389 (SD 0.054 mg per day. Six months later it was 0.378 (SD 0.084 mg per day which represents 0.020 (SD 0.010 and 0.018 (SD 0.008 mg of fluoride respectively calculated per kg bw/day. When adding the values of unwanted fluoride intake from the toothpaste shown in the literature (0.17-1.21 mg per day the estimate of the total daily intake of fluoride amounted to 0.554-1.594 mg/day and recalculated to the child's body weight to 0.027-0.077 mg/kg bw/day. Conclusions In the children studied, observed daily fluoride intake reached the threshold for safe fluoride intake. When adding the potential fluoride intake from swallowed toothpaste, alimentary intake reached the optimum range for daily fluoride intake

  16. Fluoride retention in saliva and in dental biofilm after different home-use fluoride treatments.

    Science.gov (United States)

    Souza, Daniela Correia Cavalcante; Maltz, Marisa; Hashizume, Lina Naomi

    2014-01-01

    This single-blind, randomized, crossover study aimed at assessing the long-term fluoride concentrations in saliva and in dental biofilm after different home-use fluoride treatments. The study volunteers (n = 38) were residents of an area with fluoridated drinking water. They were administered four treatments, each of which lasted for one week: twice-daily placebo dentifrice, twice-daily fluoride dentifrice, twice-daily fluoride dentifrice and once-daily fluoride mouthrinse, and thrice-daily fluoride dentifrice. At the end of each treatment period, samples of unstimulated saliva and dental biofilm were collected 8 h after the last oral hygiene procedure. Fluoride concentrations in saliva and dental biofilm were analyzed using a specific electrode. The fluoride concentrations in saliva and dental biofilm 8 h after the last use of fluoride products did not differ among treatments. The results of this study suggest that treatments with home-use fluoride products have no long-term effect on fluoride concentrations in saliva and in dental biofilm of residents of an area with a fluoridated water supply.

  17. Development of a low-cost inductively coupled argon plasma

    International Nuclear Information System (INIS)

    The aim of this investigation is to drastically reduce running costs of an inductively coupled plasma. This is done by reducing the argon consumption from 20 l/min to about 1 l/min. First, a sample introduction system operating on 0.1 l/min of carrier argon is described. This system ensures a high ratio of plasma argon and carrier argon even at the low total argon consumptions intended. Next, the developed low consumption plasma is presented. In the proposed design, air is blown perpendicularly against the outside of the torch. A different coil has been developed to make air-cooling efficient. Preliminary data on coupling efficiency for the air-cooled plasma are presented. A similarly low argon consumption has been achieved with water as an external coolant medium. It is concluded that a cheaper alternative to the current ICP has become available. (Auth.)

  18. Effects of Nitrogen contamination in liquid Argon

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Baibussinov, B.; Baldo-Ceolin, M.; Benetti, P.; Calaprice, F.; Calligarich, E.; Cambiaghi, M.; Canci, N.; Carbonara, F.; Cavanna, F.; Centro, S.; Cocco, A. G.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Gallo, V.; Grandi, L.; Meng, G.; Modena, I.; Montanari, C.; Palamara, O.; Pandola, L.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Roncadelli, M.; Rossella, M.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Ventura, S.; Vignoli, C.

    2010-06-01

    A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. The purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from ~ 10-1 ppm up to ~ 103 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (γ-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. Direct PMT signal acquisition exploiting high time resolution by fast waveform recording allowed high precision extraction of the main characteristics of the scintillation light emission in contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable starting from Script O(1 ppm) of Nitrogen concentrations. The rate constant of the quenching process induced by Nitrogen in liquid Ar has been found to be kQ(N2) = 0.11 ± 0.01 μs-1ppm-1, consistent with a previous measurement of this quantity but with significant improvement in precision. On the other hand, no evidence for absorption by N2 impurities has been found up to the higher concentrations here explored.

  19. Argon diffusion from biotite at high temperature and pressure

    Institute of Scientific and Technical Information of China (English)

    陈道公; 贾命命; 李彬贤; 陆全明; 谢鸿森; 侯渭

    1995-01-01

    t The experiments of argon diffusion dynamics for biotite were carried out at 700 -1000℃ and 0.5 - 2,0 GPa and the diffusion coefficient and activation energy using different models have been calculated. The results indicate that the pressure does affect the argon diffusion and its effect is opposite to that of temperature. When p increases, the activation energy increases and diffusion coefficient decreases. The relation between pressure, closure temperature and cooling rate has been obtained. It is postulated that in low T and high p conditions, the argon diffusion from the environment to the system could occur and incur the appearance of the external argon in minerals.

  20. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  1. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  2. Argon isotope fractionation induced by stepwise heating

    Science.gov (United States)

    Trieloff, Mario; Falter, Martina; Buikin, Alexei I.; Korochantseva, Ekaterina V.; Jessberger, Elmar K.; Altherr, Rainer

    2005-03-01

    Noble gas isotopes are widely used to elucidate the history of the rocks in which they have been trapped, either from distinct reservoirs or by accumulation following radioactive decay. To extract noble gases from their host rocks, stepwise heating is the most commonly used technique to deconvolve isotopically different components, e.g., atmospheric, in situ radiogenic, or excess radiogenic from mantle or crustal reservoirs. The accurate determination of the isotopic composition of these different components is of crucial importance, e.g., for ages obtained by 40Ar- 39Ar stepheating plateaus. However, diffusion theory-based model calculations predict that the stepwise thermal extraction process from mineral phases induces isotope fractionation and, hence, adulterates the original composition. Such effects are largely unconsidered, as they are small and a compelling experimental observation is lacking. We report the first unequivocal evidence for significant mass fractionation of argon isotopes during thermal extraction, observed on shungite, a carbon-rich Precambrian sedimentary rock. The degree of fractionation, as monitored by 38Ar/ 36Ar and 40Ar/ 36Ar ratios, very well agrees with theoretical predictions assuming an inverse square root dependence of diffusion coefficient and atomic mass, resulting in easier extraction of lighter isotopes. Hence, subatmospheric 40Ar/ 36Ar ratios obtained for argon extracted at low temperatures may not represent paleoatmospheric argon. Shungite argon resembles modern atmospheric composition, but constraints on the timing of trapping appear difficult to obtain, as shungites are multicomponent systems. In 40Ar- 39Ar stepwise heating, the isotope fractionation effect could cause systematic underestimations of plateau ages, between 0.15 and 0.4% depending on age, or considerably higher if samples contain appreciable atmospheric Ar. The magnitude of this effect is similar to the presently achieved uncertainties of this increasingly

  3. Discovery of Interstellar Hydrogen Fluoride

    CERN Document Server

    Neufeld, D A; Schilke, P; Phillips, T G; Neufeld, David A.; Zmuidzinas, Jonas; Schilke, Peter; Phillips, Thomas G.

    1997-01-01

    We report the first detection of interstellar hydrogen fluoride. Using the Long Wavelength Spectrometer (LWS) of the Infrared Space Observatory (ISO), we have detected the 121.6973 micron J = 2 - 1 line of HF in absorption toward the far-infrared continuum source Sagittarius B2. The detection is statistically significant at the 13 sigma level. On the basis of our model for the excitation of HF in Sgr B2, the observed line equivalent width of 1.0 nm implies a hydrogen fluoride abundance of 3E-10 relative to H2. If the elemental abundance of fluorine in Sgr B2 is the same as that in the solar system, then HF accounts for ~ 2% of the total number of fluorine nuclei. We expect hydrogen fluoride to be the dominant reservoir of gas-phase fluorine in Sgr B2, because it is formed rapidly in exothermic reactions of atomic fluorine with either water or molecular hydrogen; thus the measured HF abundance suggests a substantial depletion of fluorine onto dust grains. Similar conclusions regarding depletion have previously...

  4. Ruthenium olefin metathesis catalysts containing fluoride

    OpenAIRE

    Guidone, Stefano; Songis, Olivier; Falivene, Laura; Nahra, Fady; Slawin, Alexandra Martha Zoya; Jacobsen, Heiko; Cavallo, Luigi; Cazin, Catherine S. J.

    2015-01-01

    The authors gratefully acknowledge the EC through the 7th framework program (grant CP-FP 211468-2 EUMET), the Royal Society (University Research Fellowship to CSJC) for financial support. The reaction of the ruthenium complex cis-Caz-1 with silver fluoride affords the first example of an active olefin metathesis pre-catalyst containing fluoride ligands. The cis geometry of the precursor complex is key to the successful fluoride exchange reaction. Computational studies highlight the stabili...

  5. Fluoride Importance in Controlling Caries and Fluorosis

    OpenAIRE

    Gaurav Solanki

    2012-01-01

    The use of fluorides for oral health has always involved a balance between the protective benefit against dental caries and the risk of developing fluorosis. The link between fluoride and dental health was established to determining the causes of dental fluorosis or enamel mottling. Fluorosis in Indian children was highly prevalent in the early 1990s. Policy were introduced to control fluoride exposure and to reduce the prevalence of fluorosis. The study aimed of describing the prevalence, se...

  6. Argon Purification Studies and a Novel Liquid Argon Re-circulation System

    CERN Document Server

    Mavrokoridis, K; Coleman, J; Lightfoot, P K; McCauley, N; McCormick, K J; Touramanis, C

    2011-01-01

    Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapou...

  7. FLUORIDATION CHEMISTRY: EQUILIBRIA AND KINETICS OF FLUORIDE AND FLUORO-COMPLEXES

    Science.gov (United States)

    The most common fluoridating agents used by major American waterworks are hexafluorosilicic acid (H2SiF6) and sodium hexxafluorosilicate (Na2SiF6). According to the 1992 Water Fluoridation Census where 10,002 utilities responded affirmatively to fluoridating their water, 59% ...

  8. Effect of titanium tetrafluoride, amine fluoride and fluoride varnish on enamel erosion in vitro

    NARCIS (Netherlands)

    Vieira, A; Ruben, JL; Huysmans, MCDNJM

    2005-01-01

    This study aimed at evaluating the effect of 1 and 4% titanium tetrafluoride (TiF4) gels, amine fluoride (AmF) 1 and 0.25% and a fluoride varnish (FP) on the prevention of dental erosion. Two experimental groups served as controls, one with no pretreatment and another one pre-treated with a fluoride

  9. PRECIPITATION OF URANIUM PEROXIDE OF LOW FLUORIDE CONTENT FROM SOLUTIONS CONTAINING FLUORIDES

    Science.gov (United States)

    King, E.J.; Clark, H.M.

    1958-08-12

    S>A method is described for the preparation of fluoride free uraniunn peroxide precipitates, even though the solution from which the precipitation is made is contaminated with fluorides. This is accomplished by add ing aluminum ions to the solution, where they complex any fluoride present and prevent its precipitation with the uramum peroxide.

  10. High fluoride exposure in hemodialysis patients.

    Science.gov (United States)

    Bello, V A; Gitelman, H J

    1990-04-01

    The observation of higher plasma flouride levels in our hemodialysis (HD) patients than our continuous ambulatory peritoneal dialysis (CAPD) patients (4.0 +/- 0.5 mumol/L [n = 17] v 2.5 +/- 0.3 mumol/L [n = 17], P less than 0.005) prompted an evaluation of fluoride metabolism during HD. We found that serum fluoride was completely ultrafiltrable across cuprophane membranes (99% +/- 4%) and that HD produced acute changes in plasma fluoride levels that correlated well with the fluoride gradient between plasma and dialysis fluid at the start of dialysis. Our HD fluids contained significantly higher fluoride concentrations than were present in commercially prepared peritoneal dialysis fluid. Our fluids are prepared from fluoridated tap water that is purified by reverse osmosis (RO). We conclude that the different concentrations of fluoride in our dialysis fluids account for the differences in the plasma flouride concentrations between our dialysis groups. Since many HD units rely on RO systems to purify fluoridated tap water, it is likely that many HD patients are being exposed inadvertently to increased concentrations of fluoride.

  11. Fluoride in cerebrospinal fluid of patients with fluorosis.

    OpenAIRE

    Hu, Y H; Wu, S S

    1988-01-01

    The CSF fluoride level of individuals drinking water with normal fluoride content and of patients with endemic fluorosis were studied. For the purpose of studying the relationship between the dynamic equilibrium of the CSF fluoride and other body fluids, urine and blood fluoride were examined simultaneously. Fluoride was revealed in every CSF sample of the control group and its mean value was lower than that of the blood. The CSF fluoride concentration of patients with fluorosis was slightly ...

  12. 76 FR 2383 - Proposed HHS Recommendation for Fluoride Concentration in Drinking Water for Prevention of Dental...

    Science.gov (United States)

    2011-01-13

    ... that provide fluoride now include mouthrinses, fluoride supplements, and professionally applied... fluoride toothpaste (if swallowed) and fluoride supplements, have become available. Fluoride intake from... pharyngeal cancers, and sports-related craniofacial injuries: a report on recommendations of the Task...

  13. Ion-beam excitation of liquid argon

    CERN Document Server

    Hofmann, M; Heindl, T; Neumeier, A; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Wieser, J; Ulrich, A

    2015-01-01

    The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using ou...

  14. Argon laser-welded arteriovenous anastomoses.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; White, G; Lyons, R; Fujitani, R; Klein, S R; Uitto, J

    1987-11-01

    This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line. PMID:3312648

  15. Electron scattering and transport in liquid argon

    International Nuclear Information System (INIS)

    The transport of excess electrons in liquid argon driven out of equilibrium by an applied electric field is revisited using a multi-term solution of Boltzmann’s equation together with ab initio liquid phase cross-sections calculated using the Dirac-Fock scattering equations. The calculation of liquid phase cross-sections extends previous treatments to consider multipole polarisabilities and a non-local treatment of exchange, while the accuracy of the electron-argon potential is validated through comparison of the calculated gas phase cross-sections with experiment. The results presented highlight the inadequacy of local treatments of exchange that are commonly used in liquid and cluster phase cross-section calculations. The multi-term Boltzmann equation framework accounting for coherent scattering enables the inclusion of the full anisotropy in the differential cross-section arising from the interaction and the structure factor, without an a priori assumption of quasi-isotropy in the velocity distribution function. The model, which contains no free parameters and accounts for both coherent scattering and liquid phase screening effects, was found to reproduce well the experimental drift velocities and characteristic energies

  16. Pollution of liquid argon after neutron irradiation

    CERN Document Server

    Andrieux, M L; Collot, J; de Saintignon, P; Ferrari, A; Hostachy, J Y; Hoummada, A; Martin, P; Merkel, B; Puzo, P; Sauvage, D; Wielers, M

    2001-01-01

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem. (17 refs).

  17. Pollution of liquid argon after neutron irradiation

    International Nuclear Information System (INIS)

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem

  18. Urinary fluoride output in children following the use of a dual-fluoride varnish formulation

    Directory of Open Access Journals (Sweden)

    Kelly Polido Kaneshiro Olympio

    2009-06-01

    Full Text Available OBJECTIVE: This study evaluated the bioavailability of fluoride after topical application of a dual-fluoride varnish commercially available in Brazil, when compared to DuraphatTM. MATERIAL AND METHODS: The urinary fluoride output was evaluated in seven 5-year-old children after application of the fluoride varnishes, in two different phases. In the first phase (I, children received topical application of the fluoride varnish Duofluorid XII (2.92% fluorine, calcium fluoride + 2.71% fluorine, sodium fluoride, FGM TM. After 1-month interval (phase II, the same amount (0.2 mL of the fluoride varnish Duraphat (2.26% fluorine, sodium fluoride, ColgateTM was applied. Before each application all the volunteers brushed their teeth with placebo dentifrice for 7 days. Urinary collections were carried out 24 h prior up to 48 h after the applications. Fluoride intake from the diet was also estimated. Fluoride concentration in diet samples and urine was analyzed with the fluoride ion-specific electrode and a miniature calomel reference electrode coupled to a potentiometer. Data were tested by ANOVA and Tukey's post hoc test (p<0.05. RESULTS: There were significant differences in the urinary fluoride output between phases I and II. The use of Duofluorid XII did not significantly increase the urinary fluoride output, when compared to baseline levels. The application of Duraphat caused a transitory increase in the urinary fluoride output, returning to baseline levels 48 h after its use. CONCLUSIONS: The tested varnish formulation, which has been shown to be effective in in vitro studies, also can be considered safe.

  19. WARP: a double phase argon programme for dark matter detection

    International Nuclear Information System (INIS)

    WARP (Wimp ARgon Programme) is a double phase Argon detector for Dark Matter search under construction at Laboratori Nazionali del Gran Sasso. We present recent results obtained operating a prototype with a sensitive mass of 2.3 litres deep underground

  20. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.;

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...

  1. Nitrogen Removal from Molten Steel under Argon DC Glow Plasma

    Institute of Scientific and Technical Information of China (English)

    SUN Ming-shan; DING Wei-zhong; LU Xiong-gang

    2005-01-01

    Under argon DC glow plasma, the nitrogen removal from molten steel was studied. The experimental result showed that nitrogen mass percent could be reduced to 0.000 8%. The change of polarity had no impact on nitrogen removal when the nitrogen mass percent was low. The mechanism of denitrogenation of molten steel under argon DC glow plasma was discussed.

  2. Comparison of Diode and Argon Laser Lesions in Rabbit Retina

    Institute of Scientific and Technical Information of China (English)

    Hui Zhang; Xiaoxin Li; Bin Li; Jiping Da

    2004-01-01

    Purpose: To compare the histological alteration of retina with various spot intensities between diode and argon lasers in order to instruct the clinical use of 810 nm diode laser.Methods: Transpupillary retinal photocoagulations were performed on 42 eyes of 27pigmented rabbits. Histopathologic alteration of lesions in different intensities and different time intervals after irradiation produced by diode and argon laser was observed and compared using light microscopy. Areas of various lesions measured by image analysis system (CMIAS) were compared quantitatively.Results: Histopathologically, two-week-old grade 2 lesions produced by diode laser induced the disappearance of outer nuclear cells. More than a half of all showed reduction in number of outer nuclear layer cells in argon. Fibroblasts appeared in the diode grade 3lesions 5 days after irradiation. CMIAS data showed that all the areas of diode lesions immediately after photocoagulation were to be larger than those of argon laser lesions in the same spot intensity (P < 0.05). However, twenty-four hours after photocoagulation, the area of the diode lesions increased less than that of the argon laser lesions (8%vs.23%).Conclusion: The acute histological effect caused by 810 nm diode laser and argon green laser is similar,while the expansion of lesion area 24 hours after photocoagulation was less with the diode laser compared to the argon. This may be the first report in the literature regarding quantitative analysis of the delayed reaction of argon green lasers.

  3. HOUSEHOLD PURIFICATION OF FLUORIDE CONTAMINATED MAGADI (TRONA)

    DEFF Research Database (Denmark)

    Nielsen, Joan Maj; Dahi, Elian

    1997-01-01

    Purification of fluoride contaminated magadi is studied using bone char sorption and calcium precipitation. The bone char treatment is found to be workable both in columns and in batches where the magadi is dissolved in water prior to treatment. The concentrations in the solutions were 89 g magadi...... treatment method. A procedure for purification of fluoride contaminated magadi at household level is described....

  4. A comparative assessment of fluoride concentration available in saliva using daily prescribed topical fluoride agents

    Science.gov (United States)

    Talwar, Manjit; Tewari, Amrit; Chawla, H. S.; Sachdev, Vinod

    2016-01-01

    Objective: To assess the availability of fluoride concentration in saliva following the use of fluoride mouthrinse and dentifrice. Materials and Methods: The experiment was carried out in 7–15 year-old school children of Chandigarh (n = 90). The children were nonfluoride users. Baseline saliva samples were collected. The subjects were exposed to two test agents, i.e., fluoride mouthrinse (0.05%, 225 ppm F) and dentifrice (1000 ppm F) for 7 days and on the day 8, saliva samples were collected over a 20 hrs period. Wash out period of 31/2 months was there before the subjects were exposed to the second test agent. Fluoride in saliva was estimated using fluoride ion-specific electrode. Written informed consent was taken. Statistical Analysis: Kolmogorov–Smirnov test was applied to test the normality of the variables. Mann–Whitney U-test was used to compare the fluoride concentration available in saliva at respective time intervals subsequent to use of the two test agents. Results: Fluoride concentration was elevated in saliva compared to baseline for both the test agents. Fluoride mouthrinse (0.05% sodium fluoride [NaF]) and dentifrice (1000 ppm monofluorophosphate [MFP]) showed a biphasic clearance. Peak in saliva occurred at 15 mins postuse. Night-time use resulted in higher concentration of fluoride in saliva compared to baseline. There was statistically significantly higher fluoride concentration available in saliva for the dentifrice at 5 hrs, 10 hrs, and 20 hrs postuse (P fluoride concentration in saliva remained elevated to a level of 0.12 ppm for mouthrinse and 0.14 ppm for dentifrice compared to baseline (0.03 ppm) up to 20 hrs postuse. The therapeutic window though not yet established but suggested is 0.1–1 ppm for prevention of demineralization, indicating that daily use of fluoride mouthrinse and dentifrice provides fluoride concentration in saliva for the prevention of demineralization. PMID:27433050

  5. Determination of fluoride content in drinking water and tea infusions using fluoride ion selective electrode

    Directory of Open Access Journals (Sweden)

    Rajković Miloš B.

    2007-01-01

    Full Text Available Potentiometric analysis of fluoride content (as F- ion in solutions by using fluoride ion-selective electrode is simple, reliable and cheap. Very small concentrations of fluoride-ions (to 10-6 mol/dm3 can be determined by fluoride selective electrode, with regulation of ion strength of a solution and control of concentration of hydroxide ions and interfering ions of metals. The influence of pH and complexing ions of metals can be successfully regulated by the TISAB solution and by preserving pH value in the range from 5.00 to 7.00. The content of fluorides in the samples can be determined by the method of direct potentiometer, and in the case of very low concentration by standard addition method. In this paper it was analyzed the determination of fluoride ions concentration in bottled mineral waters and water from Belgrade plumbing in two Belgrade districts (Palilula and Novi Beograd and in tea, by using the fluoride selective electrode. It was determined that the content of fluoride ions in bottled mineral water significantly differs from values given on declaration, and that content of fluoride ions varies over a period of time. The content of fluoride ions in water from plumbing in two Belgrade districts at the time of analysis was significantly increased and exceeded values given in Regulation for drinking water quality. The received results from the analysis of fluorides in teas show that fluorides exist in teas in different concentrations. There are also differences between the same kinds of tea, which is noted with mint (Mentha piperitae folium, as a consequence of differences between soils where it was planted. As taking of fluorides, according to World Health Organisation recommendation (WHO, is limited in the range from 2 to 4 mg per day, it is necessary to give the content of fluorides on all products that are used in human consumption.

  6. Manufacture and properties of fluoride cement

    Science.gov (United States)

    Malata-Chirwa, Charles David

    This research work aimed at characterising composition, hydration and physical properties of fluoride cement, by studying samples of the cement obtained from Malawi, and comparing them to ordinary Portland cement. By confirming the suitable characteristics of fluoride cement through this work, the results of the research work provide a good basis for the wider adoption of fluoride cement as an alternative to ordinary Portland cement, especially in developing economies. Numerous accounts have been cited regarding the production and use of fluoride cement. Since there have not been conclusive agreement as to its properties, this study was limited to the theories of successful incorporation of fluoride compounds in the manufacture of fluoride cement. Hence, the properties and characteristics reported in this study relate to the cement currently manufactured in Malawi, and, on a comparative basis only, to that manufactured in other parts of the world. Samples of the fluoride cement used in the study were obtained by synthetic manufacture of the cement using common raw materials for the manufacture of fluoride cement that is limestone, silica sand, and fluorspar. These samples were subjected to several comparative tests used to characterise cements including examination under x-ray diffractometer, scanning electron microscopy and tests for setting time and compressive strength. Under similar laboratory conditions, it was possible to prove that fluoride cement hardens more rapidly than ordinary Portland cement. Also observed during the experimental work is that fluoride cement develops higher compressive strengths than ordinary Portland cement. The hardening and setting times are significantly different between the two cements. Also the nature of the hydration products, that is the microstructural development is significantly different in the two cements. The differences brought about between the two cements are because of the presence of fluorine during the clinkering

  7. Diethylenetriaminium hexafluoridotitanate(IV fluoride

    Directory of Open Access Journals (Sweden)

    J. Lhoste

    2008-11-01

    Full Text Available The title compound, (C6H21N4[TiF6]F, was synthesized by the reaction of TiO2, tris(2-aminoethylamine, HF and ethanol at 463 K in a microwave oven. The crystal structure consists of two crystallographically independent [TiF6]2− anions, two fluoride anions and two triply-protonated tris(2-aminoethylamine cations. The Ti atoms are coordinated by six F atoms within slightly distorted octahedra. The anions and cations are connected by intermolecular N—H...F hydrogen bonds.

  8. Method of treating fluoride contaminated wastes

    Energy Technology Data Exchange (ETDEWEB)

    Davis, P.K.; Kakaria, V.K.

    1988-04-05

    A method for treating spent aluminum smelting potliner material containing fluoride contaminants is described which comprises: adding silica to the material to form a mixture thereof; elevating the temperature of the mixture within the range of 1,000/sup 0/ to 1,700/sup 0/C. to form a slag; providing sufficient silica in the mixture and forming the slag in the presence of sufficient water for pyrohydrolysis conditions resulting in the volatilization of substantially all of the fluoride contaminants mostly in the form of hydrogen fluoride; and cooling the slag remaining after volatilizatiion of substantially all of the fluoride contaminants to produce an insoluble silicate glass-residue containing any remaining portion of the fluoride contaminants in an immobile state.

  9. Synthesis of uranium fluorides from uranium dioxide with ammonium bifluoride and ammonolysis of uranium fluorides to uranium nitrides

    Science.gov (United States)

    Yeamans, Charles Burnett

    This work presents the chemical conversion of uranium oxides to uranium fluorides, and their subsequent conversion to uranium nitrides. Uranium dioxide reacts with ammonium bifluoride at 20°C to form compound in the ammonium-uranium fluoride chemical system. This reaction occurs between solid uranium dioxide at the surface of the particles and ammonium fluoride vapor. A shrinking-sphere model demonstrated surface reaction kinetics, not mass transport by diffusion through the product layer, limit the reaction rate when the starting material consists of 100 mum uranium dioxide particles. Powder x-ray diffraction showed the reaction to be complete within 8 hours, with (NH4) 4UF8 the reaction product. High-resolution electron microcopy revealed the product is largely amorphous on a micrometer-scale, but contains well-formed crystal domains on the order of 10x10 nm. X-ray diffraction showed the reaction progresses though beta-NH4UF5, delta-(NH 4)2UF6, and gamma-(NH4)2UF6 intermediate phases before finally forming (NH4)4UF 8. Modeling the system as a series of first-order reaction suggested a fourth intermediate, possibly UF4, is likely to occur. The reaction of (NH4)4UF8 with ammonia gas at 800°C forms alpha-U2N3/UN2 solid solution products with a composition of UN1.83. The x-ray powder diffraction pattern of this product is the fcc pattern commonly referenced as that of UN2 and the lattice parameter was 0.53050 nm. Surface area increased by a factor of ten during ammonolysis, consistent with the action of a hydriding agent. The alpha-U2N 3/UN2 solid solution system formed contained 1 wt% UO 2 as an impurity. Upon subsequent heating to 1150°C for 4.5 hours under argon, the nitride sample formed UN with a UO2 impurity of 9 wt%. Based on the HRTEM images, oxidation in the UN product appears to be limited to within 20 nm of particle surfaces and grain boundaries.

  10. Merging of high speed argon plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Case, A.; Messer, S.; Brockington, S.; Wu, L.; Witherspoon, F. D. [HyperV Technologies Corp., Chantilly, Virginia 22180 (United States); Elton, R. [University of Maryland, College Park, Maryland 20742 (United States)

    2013-01-15

    Formation of an imploding plasma liner for the plasma liner experiment (PLX) requires individual plasma jets to merge into a quasi-spherical shell of plasma converging on the origin. Understanding dynamics of the merging process requires knowledge of the plasma phenomena involved. We present results from the study of the merging of three plasma jets in three dimensional geometry. The experiments were performed using HyperV Technologies Corp. 1 cm Minirailguns with a preionized argon plasma armature. The vacuum chamber partially reproduces the port geometry of the PLX chamber. Diagnostics include fast imaging, spectroscopy, interferometry, fast pressure probes, B-dot probes, and high speed spatially resolved photodiodes, permitting measurements of plasma density, temperature, velocity, stagnation pressure, magnetic field, and density gradients. These experimental results are compared with simulation results from the LSP 3D hybrid PIC code.

  11. Large vessel sealing with the argon laser.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; Lyons, R; White, G; Klein, S R; Pizzurro, D; Abergel, R P; Dwyer, R M; Uitto, J

    1987-01-01

    This study compared the histology, biochemistry, and tensile strength of laser-welded and sutured canine venotomies, arteriotomies, and arteriovenous fistulas. Twelve animals had bilateral femoral vessels studied, with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralateral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks (four animals for each type of repair), and were evaluated histologically by hematoxylin and eosin, elastin, and trichrome stains; biochemically by the formation of [3H]hydroxyproline as an index of collagen synthesis; and mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms, or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welding may be an alternative to sutures for repair of large-diameter venotomies, arteriotomies, and arteriovenous fistulas, as healing is comparable to that seen with suture repairs up to 4 weeks postoperatively. PMID:3306233

  12. Vascular Welding Using The Argon Laser

    Science.gov (United States)

    White, Rodney A.; Donayre, Carlos; Kopchok, George; White, Geoffrey; Abergel, R. Patrick; Lyons, Richard; Klein, Stanley; Dwyer, Richard; Uitto, Jouni

    1987-03-01

    This study compared the histology, biochemistry, and tensile strength of laser welded and sutured canine venotomies, arteriotomies and arteriovenous fistulas. Bilateral femoral, carotid or jugular vessels were studied with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralatral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks for each type of repair and evaluated histologically by hematoxylineosin, elastin and trichrome stains, biochemically by the formation of [3H] hyaroxyproline as an index of collagen synthesis, ana mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welaing may be an alternative to sutures for repair of large diameter venotomies, arteriotomies and arteriovenous fistulas, as they heal comparable to suture repairs up to 4 weeks postoperatively.

  13. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  14. 21 CFR 175.270 - Poly(vinyl fluoride) resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Poly(vinyl fluoride) resins. 175.270 Section 175... Substances for Use as Components of Coatings § 175.270 Poly(vinyl fluoride) resins. Poly(vinyl fluoride... the purpose of this section, poly(vinyl fluoride) resins consist of basic resins produced by...

  15. Fluoride Programs in the School Setting: Preventive Dental Health.

    Science.gov (United States)

    Rebich, Theodore, Jr.; And Others

    1982-01-01

    Two types of school-based programs that increase students' use of fluoride for preventive dental health are described. In fluoride mouthrinse programs, teachers give their students a fluoride solution once a week in a paper cup. In areas where the level of fluoride in the water supply is insufficient, the flouride tablet program is used. (JN)

  16. Fluoridation and Defluoridation. Training Module 2.230.2.77.

    Science.gov (United States)

    McMullen, L. D.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with fluoridation and fluoride feeding equipment. Enclosed are objectives, an instructor guide, student handouts and transparency masters. The module considers the principles and purposes of fluoridation, methods of feeding fluoride,…

  17. Argon laser induced changes to the carbonate content of enamel

    International Nuclear Information System (INIS)

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm-2) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  18. Evaluation of toxic action of fluorides on agricultural plants

    Directory of Open Access Journals (Sweden)

    V. N. Grishko

    2007-03-01

    Full Text Available The toxicity of potassium fluoride, sodium fluoride and ammonium fluoride for pea, maize, oat and onion was studied. It was found that the level of the toxic influence had grown with increase of fluoride concentration in the media of growth (from 5 to 100 mg of F–/l. By increase of the toxic influence the agricultural crops are disposed in the following row: oat < onion < maize < pea. Ammonium fluoride demonstrates lesser toxicity, than potassium and sodium fluorides. Under low concentrations of fluoride compounds (5 and 10 mg of F–/l stimulation of roots growth is noted only for the oat.

  19. Physiologic Conditions Affect Toxicity of Ingested Industrial Fluoride

    Directory of Open Access Journals (Sweden)

    Richard Sauerheber

    2013-01-01

    Full Text Available The effects of calcium ion and broad pH ranges on free fluoride ion aqueous concentrations were measured directly and computed theoretically. Solubility calculations indicate that blood fluoride concentrations that occur in lethal poisonings would decrease calcium below prevailing levels. Acute lethal poisoning and also many of the chronic effects of fluoride involve alterations in the chemical activity of calcium by the fluoride ion. Natural calcium fluoride with low solubility and toxicity from ingestion is distinct from fully soluble toxic industrial fluorides. The toxicity of fluoride is determined by environmental conditions and the positive cations present. At a pH typical of gastric juice, fluoride is largely protonated as hydrofluoric acid HF. Industrial fluoride ingested from treated water enters saliva at levels too low to affect dental caries. Blood levels during lifelong consumption can harm heart, bone, brain, and even developing teeth enamel. The widespread policy known as water fluoridation is discussed in light of these findings.

  20. LArGe - A liquid argon scintillation veto for GERDA

    OpenAIRE

    Heisel, M.(Max-Planck-Institut für Kernphysik, Heidelberg, Germany)

    2011-01-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the Gerda experiment. Gerda searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used...

  1. Practical reactor production of {sup 41}Ar from argon clathrate

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, J.R. E-mail: jmercer@pharmacy.ualberta.ca; Duke, M.J.M.; McQuarrie, S.A

    2000-06-01

    The radionuclide {sup 41}Ar has many ideal properties as a gas flow tracer. However, the modest cross-section of {sup 40}Ar for thermal neutron activation makes preparation of suitable activities of {sup 41}Ar technically difficult particularly for low flux reactors. Argon can however be trapped in a molecular complex called a clathrate that can then be irradiated. We prepared argon clathrate and explored its irradiation and stability characteristics. Argon clathrate can be used to provide gigabecquerel quantities of {sup 41}Ar even with low power reactors.

  2. A fluoride release-adsorption-release system applied to fluoride-releasing restorative materials.

    Science.gov (United States)

    Suljak, J P; Hatibovic-Kofman, S

    1996-09-01

    This investigation compared the initial fluoride release and release following refluoridation of three resin-modified glass-ionomer cements (Photac-Fil Applicap, Vitremer, and Fuji II LC) and a new polyacid-modified resin composite material (Dyract). After daily flouride release was measured for 8 days, specimens were refluoridated in 1,000-ppm solutions of fluoride ion for 10 minutes and fluoride release was measured for 5 days. Two further 5-day refluoridation-release periods were carried out. All materials released fluoride initially. Photac released the most; Dyract released the least. Initial release was greatest over the first few days. All materials released significantly more fluoride for 24 to 48 hours after refluoridation. Less fluoride was released with each successive refluoridation for the three glass-ionomer cements. The release from the Dyract compomer remained at a comparatively constant and significantly lower level following each refluoridation.

  3. A study of fluoride groundwater occurrence in Nathenje, Lilongwe, Malawi

    Science.gov (United States)

    Msonda, K. W. M.; Masamba, W. R. L.; Fabiano, E.

    A study was carried out to determine fluoride concentration in groundwaters of Nathenje area situated in Lilongwe District in the central region of Malawi. Water samples were collected from 176 boreholes and shallow wells during different months in 2001 and 2002. Samples were then analysed for fluoride by using a fluoride electrode and an ion selective meter. The results showed that fluoride concentrations for the rainy season varied from fluorosis in areas where the fluoride concentration was high.

  4. Physiologic Conditions Affect Toxicity of Ingested Industrial Fluoride

    OpenAIRE

    Richard Sauerheber

    2013-01-01

    The effects of calcium ion and broad pH ranges on free fluoride ion aqueous concentrations were measured directly and computed theoretically. Solubility calculations indicate that blood fluoride concentrations that occur in lethal poisonings would decrease calcium below prevailing levels. Acute lethal poisoning and also many of the chronic effects of fluoride involve alterations in the chemical activity of calcium by the fluoride ion. Natural calcium fluoride with low solubility and toxicity ...

  5. PROCESS FOR TREATING VOLATILE METAL FLUORIDES

    Science.gov (United States)

    Rudge, A.J.; Lowe, A.J.

    1957-10-01

    This patent relates to the purification of uranium hexafluoride, made by reacting the metal or its tetrafluoride with fluorine, from the frequently contained traces of hydrofluoric acid. According to the present process, UF/sub 6/ containing as an impurity a small amount of hydrofluoric acid, is treated to remove such impurity by contact with an anhydrous alkali metal fluoride such as sodium fluoride. In this way a non-volatile complex containing hydrofluoric acid and the alkali metal fluoride is formed, and the volatile UF /sub 6/ may then be removed by distillation.

  6. The effect of fluoride impregnated dental floss on enamel fluoride uptake in vitro and streptococcus mutans colonization in vivo.

    Science.gov (United States)

    Chaet, R; Wei, S H

    1977-01-01

    The conclusions reached from this investigation can be summarized as follows: Fluoride can be incorporated into unwaxed dental floss. Placement of the fluoride impregnated dental floss in acid-buffer solution results in the release of most of the fluoride in the floss. Interproximal surfaces of teeth treated in vitro with fluoride impregnated dental floss acquired significantly (approximately three fold) more enamel fluoride than those treated with plain dental floss. The number of in vivo interproximal areas harboring Streptococcus mutans was reduced significantly after treatment with fluoride impregnated dental floss. Further studies should be done to establish the biological, physiochemical, manufacturing, and practical aspects of fluoride impregnated dental floss.

  7. Dental fluorosis and skeletal fluoride content as biomarkers of excess fluoride exposure in marsupials.

    Science.gov (United States)

    Death, Clare; Coulson, Graeme; Kierdorf, Uwe; Kierdorf, Horst; Morris, William K; Hufschmid, Jasmin

    2015-11-15

    Particulate and gaseous fluoride emissions contaminate vegetation near fluoride-emitting industries, potentially impacting herbivorous wildlife in neighboring areas. Dental fluorosis has been associated with consumption of fluoride-contaminated foliage by juvenile livestock and wildlife in Europe and North America. For the first time, we explored the epidemiology and comparative pathology of dental fluorosis in Australian marsupials residing near an aluminium smelter. Six species (Macropus giganteus, Macropus rufogriseus, Wallabia bicolor, Phascolarctos cinereus, Trichosurus vulpecula, Pseudocheirus peregrinus) demonstrated significantly higher bone fluoride levels in the high (n=161 individuals), compared to the low (n=67 individuals), fluoride areas (pfluorosis in eutherian mammals. Within the high-fluoride area, 67% of individuals across the six species showed dental enamel lesions, compared to 3% in the low-fluoride areas. Molars that erupted before weaning were significantly less likely to display pathological lesions than those developing later, and molars in the posterior portion of the dental arcade were more severely fluorotic than anterior molars in all six species. The severity of dental lesions was positively associated with increasing bone fluoride levels in all species, revealing a potential biomarker of excess fluoride exposure.

  8. The Adsorption of Hydrogen Fluoride and Fluoride Ion on a Water Treatment Sludge

    OpenAIRE

    Oh, Taek-Keun; Saeki, Kazutoshi

    2009-01-01

    The hydrogen fluoride (HF) and fluoride ion (F^-) adsorption potentials of a water treatment sludge were investigated in a batch mode as a function of pH, contact time, initial fluoride concentrations, and other co-existing anions. The maximum removal of total fluoride was apparently observed at pH 5.1, whereas HF or F^- adsorptions showed nearly 100% in pH range from 2.2 to 4.3. The HF or F^- adsorption by the water treatment sludge has occurred rapidly during the initial 5.60 min and therea...

  9. Determination of fluoride content in drinking water and tea infusions using fluoride ion selective electrode

    OpenAIRE

    Rajković Miloš B.; Novaković Ivana D.

    2007-01-01

    Potentiometric analysis of fluoride content (as F- ion) in solutions by using fluoride ion-selective electrode is simple, reliable and cheap. Very small concentrations of fluoride-ions (to 10-6 mol/dm3) can be determined by fluoride selective electrode, with regulation of ion strength of a solution and control of concentration of hydroxide ions and interfering ions of metals. The influence of pH and complexing ions of metals can be successfully regulated by the TISAB solution and by preservin...

  10. The Effects of Dissolved Methane upon Liquid Argon Scintillation Light

    CERN Document Server

    Jones, B J P; Back, H O; Collin, G; Conrad, J M; Greene, A; Katori, T; Pordes, S; Toups, M

    2013-01-01

    In this paper we report on measurements of the effects of dissolved methane upon argon scintillation light. We monitor the light yield from an alpha source held 20 cm from a cryogenic photomultiplier tube (PMT) assembly as methane is injected into a high-purity liquid argon volume. We observe significant suppression of the scintillation light yield by dissolved methane at the 10 part per billion (ppb) level. By examining the late scintillation light time constant, we determine that this loss is caused by an absorption process and also see some evidence of methane-induced scintillation quenching at higher concentrations (50-100 ppb). Using a second PMT assembly we look for visible re-emission features from the dissolved methane which have been reported in gas-phase argon methane mixtures, and we find no evidence of visible re-emission from liquid-phase argon methane mixtures at concentrations between 10 ppb and 0.1%.

  11. Evidence of electric breakdown induced by bubbles in liquid argon

    CERN Document Server

    Bay, F; Murphy, S; Resnati, F; Rubbia, A; Sergiampietri, F; Wu, S

    2014-01-01

    We report on the results of a high voltage test in liquid argon in order to measure its dielectric rigidity. Under stable conditions and below the boiling point, liquid argon was found to sustain a uniform electric field of 100 kV/cm, applied in a region of 20 cm$^2$ area across 1 cm thick gap. When the liquid is boiling, breakdowns may occur at electric fields as low as 40 kV/cm. This test is one of the R&D efforts towards the Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER) as proposed Liquid Argon Time Projection Chamber (LAr TPC) for the LBNO observatory for neutrino physics, astrophysics and nucleon decay searches.

  12. A purity monitoring system for liquid argon calorimeters

    International Nuclear Information System (INIS)

    For liquid argon calorimeters electronegative impurities dissolved in the medium degrade the detector response and deteriorate the energy resolution, especially at high energies. A concept for a purity monitoring system for liquid argon calorimeters has been developed and is presented here. Special combined monitors of 241Am- and 207Bi-cells are used to monitor the concentration of impurities. The working principle as well as results from test measurements are discussed

  13. Size Determination of Argon Clusters from a Rayleigh Scattering Experiment

    Institute of Scientific and Technical Information of China (English)

    LEI An-Le; ZHAI Hua-Jin; LIU Bing-Chen; LI Zhong; NI Guo-Yuan; XU Zhi-Zhan

    2000-01-01

    Argon clusters are produced in the process of adiabatic expansion of a high backing pressure gas into vacuum through a nozzle. The cluster size is determined by a Rayleigh scattering measurement. The scattered signal measured is proportional to the 2.78th power of gas stagnation pressure. The average cluster sizes vary from 100 to more than 12000 atoms/cluster with the argon gas backing pressures ranging between 3 to 45 atm.

  14. Pulse shape discrimination studies in a liquid Argon scintillation detector

    OpenAIRE

    Pollmann, T.

    2007-01-01

    Liquid rare gases have been gaining popularity as detector media in rare event searches, especially dark matter experiments, and one factor driving their adoption is the possibility to recognise different types of ionizing radiation by the pulse shapes they evoke. This work on pulse shape discrimination in a liquid argon scintillation detector was done in the framework of the GERDA experiment, where liquid argon scintillation signals may be used for background suppression purposes. Liquid arg...

  15. Power Consideration for Pulsed Discharges in Potassium Seeded Argon

    Institute of Scientific and Technical Information of China (English)

    XIA Sheng-Guo; HE Jun-Jia; LIU Ke-Fu

    2007-01-01

    Minimization of energy consumed in plasma generation is critical for applications, in which a large volume of plasmas is needed. We suggest that a high electron density atmospheric pressure plasmas can be generated by pulsed discharges in potassium seeded argon at an elevated temperature with a very small power input. The ionization efficiency and power budget of pulsed discharges in such plasmas are analytically studied. The results show that ionization efficiency of argon, especially at small reduced electric field E/N (the ratio of the electric field to the gas number density), is improved effectively in the presence of small amount of potassium additives. Power input of pulsed discharge to sustain a prescribed average level of ionization in potassium seeded argon is three orders of magnitude lower than that in pure argon. Further, unlike in pure argon, it is found that very short high-voltage pulses with very high repetition rates are unnecessary in potassium seeded argon. A pulse with 100ns of pulse duration, 5kHz of repetition rate, and 2Td (1 Td = 1 ×10-21 Vm2) of E/N is enough to sustain an electron density of 10l9m-3 in 1 atm 1500 K Ar+0.1% K mixture, with a very small power input of about 0.08 × 104 W/m3.

  16. Energy resolution for α-particles in doped liquid argon

    International Nuclear Information System (INIS)

    The report describes experiments on the effect of allene doped in liquid argon. In the case of doped argon, a large amount of charge is obtained even at low electric fields and the measured charge increases with the field gradually. This can be explained as follows; part of deposited energy which does not form charge in pure argon contributes to charge signal in doped argon through scintillation photons which ionize allene molecules. The main factors determining the energy resolution for α-particles are considered to be (1) fluctuation in the number of produced ion-electron pairs as expressed by the Fano factor, (2) fluctuation in recombination process, (3) fluctuation in photoionization, (4) fluctuation due to the condition of radioactive source and surface of electrodes, (5) fluctuation in geometrical efficiency due to the range and emission angle of α-particles in liquid argon, and (6) electronic noise of amplifier. The factors (1) and (3) can be neglected because of a large number of associated electrons or photons. In pure liquid argon, the factor (2) may be a cause of bad resolution since the fraction of the produced ion-electron paris which do not recombine is small and the photoionization process never occurs for photons emitted through recombination. (N.K.)

  17. Fluoride release and uptake capacities of fluoride-releasing restorative materials.

    Science.gov (United States)

    Attar, Nuray; Turgut, Melek D

    2003-01-01

    Many fluoride-releasing dental materials are being sold on the basis of their cariostatic properties. However, the amount fluoride release of these materials is still uncertain. This study investigated the fluoride release and uptake characteristics of four flowable resin composites (Heliomolar Flow, Tetric Flow, Wave, Perma Flo), one flowable compomer (Dyract flow), one conventional glass ionomer cement mixed with two different powder/liquid ratios (ChemFlex Syringeable and ChemFlex Condensable), one packable resin composite (SureFil), one ion-releasing composite (Ariston pHc) and one resin-modified glass ionomer cement (Vitremer). Seven discs (6-mm diameter and 1.5-mm height) were prepared for each material. Each disc was immersed in 3.5 ml of deionized water within a plastic vial and stored at 37 degrees C. The deionized water was changed every 24 hours and the release of fluoride was measured for 30 days. At the end of this period, the samples were recharged with 2 ml of 1.23% acidulated phosphate fluoride (APF) gel for four minutes. Then, all samples were reassessed for an additional 10 days. The fluoride release of all samples was measured with a specific fluoride electrode and an ionanalyzer. Statistical analyses were conducted using two-way repeated measure ANOVA and Duncan's multiple range tests. For all tested materials, the greatest fluoride release was observed after the first day of the study (p0.05). Ariston pHc released the highest amount of fluoride, followed by ChemFlex Syringeable, Vitremer and ChemFlex Condensable. There were statistically significant differences among these materials (p<0.05). Fluoride release of all materials were significantly increased after the first day following refluoridation and Ariston pHc released the greatest among all materials (p<0.01). At the end of two days of refluoridation, the fluoride release rate for each material dropped quickly and stabilized within three days.

  18. Fluoride geochemistry of thermal waters in Yellowstone National Park: I. Aqueous fluoride speciation

    Science.gov (United States)

    Deng, Y.; Nordstrom, D.K.; Blaine, McCleskey R.

    2011-01-01

    Thermal water samples from Yellowstone National Park (YNP) have a wide range of pH (1-10), temperature, and high concentrations of fluoride (up to 50mg/l). High fluoride concentrations are found in waters with field pH higher than 6 (except those in Crater Hills) and temperatures higher than 50??C based on data from more than 750 water samples covering most thermal areas in YNP from 1975 to 2008. In this study, more than 140 water samples from YNP collected in 2006-2009 were analyzed for free-fluoride activity by ion-selective electrode (ISE) method as an independent check on the reliability of fluoride speciation calculations. The free to total fluoride concentration ratio ranged from 99% at high pH. The wide range in fluoride activity can be explained by strong complexing with H+ and Al3+ under acidic conditions and lack of complexing under basic conditions. Differences between the free-fluoride activities calculated with the WATEQ4F code and those measured by ISE were within 0.3-30% for more than 90% of samples at or above 10-6 molar, providing corroboration for chemical speciation models for a wide range of pH and chemistry of YNP thermal waters. Calculated speciation results show that free fluoride, F-, and major complexes (HF(aq)0, AlF2+, AlF2+ and AlF30) account for more than 95% of total fluoride. Occasionally, some complex species like AlF4-, FeF2+, FeF2+, MgF+ and BF2(OH)2- may comprise 1-10% when the concentrations of the appropriate components are high. According to the simulation results by PHREEQC and calculated results, the ratio of main fluoride species to total fluoride varies as a function of pH and the concentrations and ratios of F and Al. ?? 2011.

  19. Well Waters Fluoride in Enugu, Nigeria

    Directory of Open Access Journals (Sweden)

    EI Ugwuja

    2012-03-01

    Full Text Available Abnormal fluoride levels in drinking water have been associated with adverse health effects. To determine the fluoride content of well waters in Enugu, southeastern Nigeria, water samples from 50 artisan wells chosen by multistage sampling procedure from the 5 zones of Enugu municipality were analyzed in duplicates for their fluoride content. The zonal mean values were 0.60, 0.70, 0.62, 0.62, and 0.63 mg/L for Abakpa Nike, Achara Layout, Obiagu/ Ogui, Trans Ekulu and Uwani, respectively (p<0.05. The mean value for the whole city was 0.63 mg/L. Although, the mean level of fluoride recorded in this study is currently within safe limits (1.5 mg/L, WHO 2011, it is important to monitor continuously the fluoride content of well waters in the municipality in view of the increasing industrial activities going on in the city and heavy reliance on well water for domestic purposes and the widespread use of consumer products containing fluoride.

  20. Debating Water Fluoridation Before Dr. Strangelove.

    Science.gov (United States)

    Carstairs, Catherine

    2015-08-01

    In the 1930s, scientists learned that small amounts of fluoride naturally occurring in water could protect teeth from decay, and the idea of artificially adding fluoride to public water supplies to achieve the same effect arose. In the 1940s and early 1950s, a number of studies were completed to determine whether fluoride could have harmful effects. The research suggested that the possibility of harm was small. In the early 1950s, Canadian and US medical, dental, and public health bodies all endorsed water fluoridation. I argue in this article that some early concerns about the toxicity of fluoride were put aside as evidence regarding the effectiveness and safety of water fluoridation mounted and as the opposition was taken over by people with little standing in the scientific, medical, and dental communities. The sense of optimism that infused postwar science and the desire of dentists to have a magic bullet that could wipe out tooth decay also affected the scientific debate. PMID:26066938

  1. Analysis of fluoride concentration in solutions prepared at dispensing pharmacies

    Directory of Open Access Journals (Sweden)

    Eduardo Pizzatto

    2011-07-01

    Full Text Available Introduction: Fluoride plays an important role in oral health promotion and is considered important in dental caries prevention both in children and adults. Fluoride is widely used at high-risk conditions of caries, when the use of fluoride-containing mouthwashes is recommended, considering that fluoride itself reduces the risk of dental caries. Objective: To evaluate the fluoride concentration in solutions prepared at different dispensing pharmacies in the city of Curitiba – PR, Brazil. Material and methods: The analysis of fluoride concentration was preformed through Ion Chromatography method (DIONEX. Results: The results obtained through this analysis showed that all solutions presented fluoride concentration above that required in the dentist’s prescription, varying between 5.48% and 24.02% more fluoride, at absolute concentration. Conclusion: This finding highlights the increasing risk of fluoride acute intoxication in cases of accidental ingestion of the solution.

  2. Chemisorption of uranium hexa-fluoride on sodium fluoride pellets

    International Nuclear Information System (INIS)

    This paper comprises kinetics of chemical reaction or rather chemisorption of uranium hexafluoride gas on sodium fluoride pellets. The chemisorption is essentially irreversible at room temperature, while the process reverses at high temperature above 280 deg C. This chemisorption process was experimentally conducted in static condition at room temperature and its kinetics was studied. In the experiments, practically pure UF6 was used and the effects of gas pressure and weight of NaF pellets, were studied. In this heterogenous reaction, in which diffusion through ash layer is followed by chemical reaction, the reaction part is instantaneous and is first order with respect to gas concentration. Since the process of chemisorption is not only pure chemical reaction but also gas diffusion through ash layer, the rate constant depreciates with the percentage loading of UF6 on NaF pellets. The kinetic equation for the above process has been established for a particular size of NaF pellets and pellet porosity. (author)

  3. New argon-argon (40Ar/39Ar) radiometric age dates from selected subsurface basalt flows at the Idaho National Laboratory, Idaho

    Science.gov (United States)

    Hodges, Mary K.; Turrin, Brent D.; Champion, Duane E.; Swisher, Carl C.

    2015-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected samples for 12 new argon-argon radiometric ages from eastern Snake River Plain olivine tholeiite basalt flows in the subsurface at the Idaho National Laboratory. The core samples were collected from flows that had previously published paleomagnetic data. Samples were sent to Rutgers University for argon-argon radiometric dating analyses.

  4. Daily Fluoride Intake from Iranian Green Tea: Evaluation of Various Flavorings on Fluoride Release

    Science.gov (United States)

    Maleki, Afshin; Daraei, Hiua; Mohammadi, Elham; Zandi, Shiva; Teymouri, Pari; Mahvi, Amir Hossien; Gharibi, Fardin

    2016-01-01

    With increased awareness of the health benefits of the compounds in green tea, especially polyphenols, its consumption is rising. The main purpose of this study is to determine the effect of different additives on the released fluoride into tea liquor and also daily fluoride intake. The concentrations of fluoride, nitrate, sulfate, and chloride were measured in 15 different flavored green teas (Refah-Lahijan). The fluoride and other anion concentrations were measured by ion chromatography method. The data were analyzed with Statistical Package for the Social Sciences version 16.0. The results showed that the minimum and maximum concentrations of fluoride in the green tea infusions were 0.162 mg/L (cinnamon-flavored green tea) and 3.29 mg/L (bagged peach-flavored green tea), respectively. The mean concentration of fluoride in the green tea leaves was 52 mg/kg, and approximately 89% of the fluoride was released from the green tea leaves into the infusions after brewing. The fluoride concentrations varied significantly among the examined green teas (P 0.05). Finally, drinking of the studied green teas cannot make a significant contribution to the daily dietary intake of F for consumers. PMID:27042093

  5. Fluoride concentration in plaque in adolescents after topical application of different fluoride varnishes.

    Science.gov (United States)

    Sköld-Larsson, K; Modéer, T; Twetman, S

    2000-03-01

    The aim of the study was to measure the fluoride (F) concentration in plaque after a single topical application of different fluoride varnishes with contrasting levels of F. Thirty adolescents (12-17 years) with fixed orthodontic appliances were randomly assigned to one of three groups: Bifluoride (6% F), Duraphat (2.23% F) and Fluor Protector (0.1% F). The varnishes were applied after professional cleaning in one upper quadrant, leaving the opposite quadrant untreated according to the split-mouth technique. Pooled plaque samples from each quadrant were collected at baseline and 3 days, 7 days and 30 days after the varnish treatment, and fluoride was analysed by microdiffusion. All fluoride varnishes increased the fluoride concentration in plaque compared with baseline, and the mean values varied between 23 and 138 ng F/mg after 3 days, depending on varnish F concentration. Compared with the control quadrant, statistically significant elevations were recorded for Bifluoride after 3 days and 7 days and Duraphat after 3 days, while no significant differences were revealed in the Fluor Protector group. The fluoride concentration in plaque was back to baseline levels for all participants in the Duraphat group after 7 days, while some individuals in the Bifluoride and Fluor Protector groups still registered slightly increased levels after 30 days. The results suggest that fluoride varnish treatments resulted in elevated fluoride levels in plaque adjacent to fixed orthodontic appliances for a period of up to 1 week, although different patterns was disclosed for the various brands.

  6. Determination of Fluoride in the Bottled Drinking Waters in Iran

    OpenAIRE

    Amanlou, Massoud; Hosseinpour, Maedeh; Azizian, Homa; Khoshayand, Mohammad Reza; Navabpoor, Mojtaba; Souri, Effat

    2010-01-01

    Fluoride is recognized as an effective agent for dental caries prevention. Generally, the main source of fluoride intake is drinking water. In this study, fluoride content in 18 commercial brands of bottled waters was investigated. Six samples from each batch of 18 Iranian commercial brands of bottled waters were supplied. The fluoride content of samples was analyzed by Fluoride Ion Selective Electrode. The mean ± SD fluoride content of the bottled waters was 0.202 ± 0.00152 mg/L with a range...

  7. Evolution of Martian atmospheric argon: Implications for sources of volatiles

    Science.gov (United States)

    Hutchins, Kevin S.; Jakosky, Bruce M.

    We have examined processes affecting isotopes of argon (36Ar, 38Ar, 40Ar) in order to determine important atmospheric sources and sinks. Our simple model for argon evolution incorporates production of radiogenic argon in the mantle, outgassing of all argon species by extrusive and intrusive volcanism, and loss to space by knock-on sputtering above the exobase. Sputtering has been shown previously to be an important loss process for atmospheric species, especially isotopes of noble gases, which have few other mechanisms of escape. The integrated evolution of argon (36Ar, 38Ar, and 40Ar, respectively) is modeled in terms of these variables: (1) the planetary concentration of potassium, (2) the fraction of juvenile argon released catastrophically during the first 600 Myr., (3) potential variation in the time-history of sputtering loss from that suggested by Luhmann et al. [1992], and (4) the volume of total outgassing to the surface as compared to outgassing contributed by volcanic release. Our results indicate that Mars has lost between 85-95% of 36Ar and 70-88% of outgassed 40Ar. Due to this substantial loss, the planet must have outgassed the equivalent of between 10 and 100 times the total volume of gases released by extrusive and intrusive volcanics. This indicates that volcanic outgassing, alone, is insufficient to explain the present-day abundances of 36Ar and 40Ar in the Martian atmosphere. Similar calculations for 20Ne suggest outgassed volumes of between 100 and 1800 times in excess of that due to volcanism. This results in a distinct Ne/Ar elemental fractionation, with a preference for outgassing argon, of the order of 10 to 17. Although the results must be evaluated within the model uncertainties, the results are compelling in that they unequivocally show the existence of additional sources of atmospheric volatiles and helps define a means to identify them.

  8. Caries inhibition by fluoride-releasing primers.

    Science.gov (United States)

    Kerber, L J; Donly, K J

    1993-10-01

    This study evaluated the caries inhibition of dentin primers with the addition of fluoride. Two standardized Class V preparations were placed in 20 molars, the gingival margin placed below the cementoenamel junction and the occlusal margin placed in enamel. Two dentin primers (Syntac and ScotchPrep) were placed in equal numbers of 20 preparations, according to manufacturer's instructions. Ammonium fluoride (10% by weight) was then added to these primers and they were placed in the remaining 20 preparations, opposing the non-fluoridated primer of the same system. All teeth were then restored with a non-fluoridated resin composite. All teeth were subjected to an artificial caries challenge (pH 4.2) for 5 days. Sections of 100 microns were obtained, photographed under polarized light microscopy, then demineralized areas were quantitated by digitization. Results demonstrated the mean areas (mm2 +/- S.D.) demineralization at 0.25 mm, 0.5 mm and 1.0 mm from the restoration margin to be: Syntac/fluoride (1.44 +/- 0.49, 1.68 +/- 0.54, 3.72 +/- 0.74); Syntac (1.99 +/- 0.58, 1.50 +/- 0.35, 2.98 +/- 1.26); ScotchPrep/fluoride (1.23 +/- 0.68, 1.55 +/- 0.64, 3.08 +/- 1.16); ScotchPrep (1.90 +/- 0.83, 1.71 +/- .038, 3.36 +/- 0.62). A paired t-test indicated primers with fluoride to demonstrate significantly less demineralization 0.25 mm from the restoration margin (P < 0.07). PMID:7880460

  9. Fluoride release and uptake abilities of different fissure sealants

    Science.gov (United States)

    Andenna, Gianluigi; Ceci, Matteo; Beltrami, Riccardo; Colombo, Marco; Cucca, Lucia

    2016-01-01

    Background The long-term capability of resin sealants and glass ionomer cements to release fluoride is associated to a reduction in pit and fissure caries. The regular use of fluoride varnishes/toothpastes can result in the absorption of fluoride into the sealant. The objective of the present study was to assess the fluoride release/uptake capacities of different fissure sealants. Material and Methods Three different fissure sealants (Fuji Triage/GC, Fissurit FX/Voco and Grandio Seal/Voco) were examined. Ten discs of each material were prepared. Each disc was incubated with distilled water and then the solution analyzed for diluted for fluoride concentration, using a combination of fluoride electrode (OrionGP 1 S/N 13824, Orion Research Inc, Boston, MA, USA) connected to an expandable ion analyzer (Orion 720A, Orion Research Inc, Boston, MA, USA). Standard curves between 1 and 100 ppm F- were used to calibrate the electrode. Cumulative fluoride release was measured on days 1, 2, 3, 5, 7, 21, 35 and 49, then two different fluoride varnishes/pastes (Profluorid Varnish/Voco, MI Paste Plus/GC), were applied to the sealants tested, and fluoride release (after reuptake) was measured on days 56, 70 and 84. Results Kruskal Wallis test confirmed significant differences in fluoride release between Fuji Triage/GC and Fissurit FX/Voco and Grandio Seal/Voco from day 1 (P fluoride varnish Profluorid Varnish enhanced the fluoride release for all sealants (P fluoride release for all sealants except for Fuji Triage/GC (P > 0.05). Conclusions The GIC-based sealant (Fuji Triage/GC) released significantly more fluoride than the resin sealants tested. The exposure to the fluoridated varnish (Profluorid Varnish) significantly recharged the sealants tested more than the CPP-ACPF toothpaste (MI Paste Plus). Key words:Fissure sealants, fluoride release, fluoride uptake, glass ionomer cements. PMID:27398179

  10. Characterisation of GERDA Phase-I detectors in liquid argon

    International Nuclear Information System (INIS)

    GERDA will search for neutrinoless double beta decay in 76Ge by submerging bare enriched HPGe detectors in liquid argon. In GERDA Phase-I, reprocessed enriched-Ge detectors, which were previously operated by the Heidelberg-Moscow and IGEX collaborations, and reprocessed natural-Ge detectors from Genius-TF, will be redeployed. We have tested the operation and performance of bare HPGe detectors in liquid nitrogen and in liquid argon over more than three years with three non-enriched p-type prototype detectors. The detector handling and mounting procedures have been defined and the Phase-I detector technology, the low-mass assembly and the long-term stability in liquid argon have been tested successfully. The Phase-I detectors were reprocessed by Canberra Semiconductor NV, Olen, according to their standard technology but without the evaporation of a passivation layer. After their reprocessing, the detectors have been mounted in their low-mass holders and their characterisation in liquid argon performed. The leakage current, the counting characteristics and the efficiency of the detectors have been measured. The testing of the detectors was carried out in the liquid argon test stand of the GERDA underground Detector Laboratory (GDL) at LNGS. The detectors are now stored underground under vacuum until their operation in GERDA.

  11. The Spectroscopic Detectability of Argon in the Lunar Atmosphere

    CERN Document Server

    Parker, J W; Gladstone, G R; Shull, J M; Parker, Joel Wm.

    1999-01-01

    Direct measurements of the abundance of argon in the lunar atmosphere were made in 1973 by instruments placed on the Moon during the Apollo 17 mission, but the total daytime abundance is unknown due to instrument saturation effects; thus, until we are able to return to the Moon for improved direct measurements, we must use remote sensing to establish the daytime abundance. In this paper, we present a complete analysis of the potential for measuring argon in the lunar atmosphere via emission-line or absorption-line observations. We come to the surprising conclusion that the lower limit established by the in situ lunar argon measurements implies that any absorption-line measurement of argon in the lower, dayside lunar atmosphere requires analysis in the optically-thick regime. In light of this result, we present the results of our EUVS sounding rocket observations of the lunar occultation of Spica, which provide a new upper limit on the abundance of argon in the daytime lunar atmosphere. We also re-analyze a re...

  12. Thermodynamic data-base for metal fluorides

    International Nuclear Information System (INIS)

    This study is aimed at collecting useful data of thermodynamic properties of various metal fluorides. Many thermodynamic data for metal fluorides are needed for the effective development, but no report of data-base was published. Accordingly, the objective of this report is to rearrange systematically the existing thermodynamic data based on metal fluorides and is to use it as basic data for the development of pyrochemical process. The physicochemical properties of various metal fluorides and metals were collected from literature and such existing data base as HSC code, TAPP code, FACT code, JANAF table, NEA data-base, CRC handbook. As major contents of the thermodynamic data-base, the physicochemical properties such as formation energy, viscosity, density, vapor pressure, etc. were collected. Especially, some phase diagrams of eutectic molten fluorides are plotted and thermodynamic data of liquid metals are also compiled. In the future, the technical report is to be used as basic data for the development of the pyrochemical process which is being carried out as a long-term nuclear R and D project

  13. Thermodynamic data-base for metal fluorides

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Hyung; Lee, Byung Gik; Kang, Young Ho and others

    2001-05-01

    This study is aimed at collecting useful data of thermodynamic properties of various metal fluorides. Many thermodynamic data for metal fluorides are needed for the effective development, but no report of data-base was published. Accordingly, the objective of this report is to rearrange systematically the existing thermodynamic data based on metal fluorides and is to use it as basic data for the development of pyrochemical process. The physicochemical properties of various metal fluorides and metals were collected from literature and such existing data base as HSC code, TAPP code, FACT code, JANAF table, NEA data-base, CRC handbook. As major contents of the thermodynamic data-base, the physicochemical properties such as formation energy, viscosity, density, vapor pressure, etc. were collected. Especially, some phase diagrams of eutectic molten fluorides are plotted and thermodynamic data of liquid metals are also compiled. In the future, the technical report is to be used as basic data for the development of the pyrochemical process which is being carried out as a long-term nuclear R and D project.

  14. Emissions of fluorides from welding processes.

    Science.gov (United States)

    Szewczyńska, Małgorzata; Pągowska, Emilia; Pyrzyńska, Krystyna

    2015-11-01

    The levels of fluoride airborne particulates emitted from welding processes were investigated. They were sampled with the patented IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM), personal inhalable sampler for simultaneous collection of the inhalable and respirable size fractions. Ion chromatography with conductometric detection was used for quantitative analysis. The efficiency of fluoride extraction from the cellulose filter of the IOM sampler was examined using the standard sample of urban air particle matter SRM-1648a. The best results for extraction were obtained when water and the anionic surfactant N-Cetyl-N-N-N-trimethylammonium bromide (CTAB) were used in an ultrasonic bath. The limits of detection and quantification for the whole procedure were 8μg/L and 24μg/L, respectively. The linear range of calibration was 0.01-10mg/L, which corresponds to 0.0001-0.1mg of fluorides per m(3) in collection of a 20L air sample. The concentration of fluorides in the respirable fraction of collected air samples was in the range of 0.20-1.82mg/m(3), while the inhalable fraction contained 0.23-1.96mg/m(3) of fluorides during an eight-hour working day in the welding room. PMID:26574102

  15. Removing Fluoride Ions with Continously Fed Activated Alumina.

    Science.gov (United States)

    Wu, Yeun C.; Itemaking, Isara Cholapranee

    1979-01-01

    Discussed is the mathematical basis for determining fluoride removal during water treatment with activated alumina. The study indicates that decreasing particle size decreases the pore diffusion effect and increases fluoride removal. (AS)

  16. Metastable argon beam source using a surface wave sustained plasma

    International Nuclear Information System (INIS)

    A new source of metastable argon atoms in the thermal energy range is reported. The source is based on expanding a plasma sustained by electromagnetic surface waves in a quartz tube through a converging nozzle and extracting a beam from the supersonic free-expansion jet. The beam was characterized by time-of-flight measurements which yielded the absolute intensity and velocity distribution of the argon metastables. The source produced a maximum intensity of 6.2x1014 metastables per second per steradian, the highest time-averaged intensity of thermal argon metastables of any source reported to date. A simple picture of an expanding plasma in a recombination regime is used to explain the dependence of the metastable intensity on absorbed power

  17. On the electric breakdown in liquid argon at centimeter scale

    Science.gov (United States)

    Auger, M.; Blatter, A.; Ereditato, A.; Goeldi, D.; Janos, S.; Kreslo, I.; Luethi, M.; von Rohr, C. Rudolf; Strauss, T.; Weber, M. S.

    2016-03-01

    We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  18. The Simulation of the ATLAS Liquid Argon Calorimetry

    CERN Document Server

    Archambault, J P; Carli, T; Costanzo, D; Dell'Acqua, A; Djama, F; Gallas, M; Fincke-Keeler, M; Khakzad, M; Kiryunin, A; Krieger, P; Leltchouk, M; Loch, P; Ma, H; Menke, S; Monnier, E; Nairz, A; Niess, V; Oakham, G; Oram, C; Pospelov, G; Rajagopalan, S; Rimoldi, A; Rousseau, D; Rutherfoord, J; Seligman, W; Soukharev, A; Strízenec, P; Tóth, J; Tsukerman, I; Tsulaia, V; Unal, G; Grahn, K J

    2008-01-01

    In ATLAS, all of the electromagnetic calorimetry and part of the hadronic calorimetry is performed by a calorimeter system using liquid argon as the active material, together with various types of absorbers. The liquid argon calorimeter consists of four subsystems: the electromagnetic barrel and endcap accordion calorimeters; the hadronic endcap calorimeters, and the forward calorimeters. A very accurate geometrical description of these calorimeters is used as input to the Geant 4-based ATLAS simulation, and a careful modelling of the signal development is applied in the generation of hits. Certain types of Monte Carlo truth information ("Calibration Hits") may, additionally, be recorded for calorimeter cells as well as for dead material. This note is a comprehensive reference describing the simulation of the four liquid argon calorimeteter components.

  19. Energy resolution studies of liquid argon ionization detectors

    International Nuclear Information System (INIS)

    A gridded ionization chamber was used to study the energy resolution in liquid argon with electrons from a 207Bi radioactive source. Argon was purified in the gas phase with a simple and reliable system, capable of reducing the impurity level below 1 ppb O2 equivalent, as inferred by a pulse shape analysis of the ionization signals. The electron spectrum was measured at different drift fields, up to 10.9 KV/cm. At this maximum field, a total energy resolution of 32 keV (fwhm), corresponding to a noise-subtracted energy resolution of 26 keV (fwhm), was obtained for the 976 keV conversion electron line. This value is the best reported so far in liquid argon but is still a factor of seven worse than the theoretical limit set by the Fano factor. The reasons for this discrepancy are discussed. (orig.)

  20. Liquid Argon Calorimetry with LHC-Performance Specifications

    CERN Multimedia

    2002-01-01

    % RD-3 Liquid Argon Calorimetry with LHC-Performance Specifications \\\\ \\\\Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. Among the techniques used so far, or under development, the liquid argon sampling calorimetry offers high radiation resistence, good energy resolution (electromagnetic and hadronic), excellent calibration stability and response uniformity. Its rate capabilities, however, do not yet match the requirements for LHC. \\\\ \\\\The aim of this proposal is to improve the technique in such a way that high granularity, good hermiticity and adequate rate capabilities are obtained, without compromising the above mentioned properties. To reach this goal, we propose to use a novel structure, the $^{\\prime\\prime}$accordion$^{\\prime\\prime}$, coupled to fast preamplifiers working at liquid argon temperature. Converter and readout electrodes are no longer planar and perpendicular to particles, as usual, but instead they are wiggled around a plane containing particles. ...

  1. A therapeutic experience on Port Wine hemangiomas with Argon Laser

    Directory of Open Access Journals (Sweden)

    Farahvash M

    1997-09-01

    Full Text Available Port wine stains are benign but cosmetically devasting congenital angiomas. The argon laser is a therapeutic device newly applied to this condition. Our program was begun 6 years ago. From the beginning, the study was conceived as a clinical investigation of both the port wine stain and its argon laser therapy. A total of 218 patients with port wine stains have been studied and many aspects of their clinical condition detailed. Employing the Argon laser, test spots have been carried out in patients and the results have been analyzed with clinical aspects of the lesions. Altogether, 501 treatments were performed in 218 patients. Good to excellent results were obtained in 81 patients. Moderate Result was obtained in 31 weak result in 65 patients. Most common complication were hyperpigmentation and depressed scar.

  2. On the Electric Breakdown in Liquid Argon at Centimeter Scale

    CERN Document Server

    Auger, M; Ereditato, A; Goeldi, D; Janos, S; Kreslo, I; Luethi, M; von Rohr, C Rudolf; Strauss, T; Weber, M S

    2015-01-01

    We present a study on the dependence of electric breakdown discharge parameters on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  3. Uranyl fluoride luminescence in acidic aqueous solutions

    International Nuclear Information System (INIS)

    Luminescence emission spectra and decay rates are reported for uranyl species in acidic aqueous solutions containing HF or added NaF. The longest luminescence lifetime, 0.269 ± 0.006 ms, was observed from uranyl in 1 M HF + 1 M HClO4 at 296 K and decreased with increasing temperature. Based on a luminescence dynamics model that assumes equilibrium among electronically excited uranyl fluoride species and free fluoride ion, this long lived uranyl luminescence in aqueous solution is attributed primarily to UO2F2. Studies on the effect of added LiNO3 or Na2WO4·2H2O showed relatively weak quenching of uranyl fluoride luminescence which suggests that high sensitivity determination of the UF6 content of WF6 gas should be feasible via uranyl luminescence analysis of hydrolyzed gas samples of impure WF6

  4. Cancer incidence and mortality in workers exposed to fluoride

    DEFF Research Database (Denmark)

    Grandjean, P; Olsen, J H; Jensen, O M;

    1992-01-01

    Although a recent bioassay showed increased frequency of bone cancer in rats with high oral intake of fluoride, the data are reported as equivocal evidence of carcinogenicity. In humans, occupational fluoride exposure may cause skeletal fluorosis, and our earlier follow-up of fluoride...

  5. 40 CFR 180.575 - Sulfuryl fluoride; tolerances for residues.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Sulfuryl fluoride; tolerances for... § 180.575 Sulfuryl fluoride; tolerances for residues. (a)(1) General. Tolerances are established for residues of sulfuryl fluoride in or on the following commodities from the postharvest fumigation...

  6. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated...

  7. COMPLEX FLUORIDES OF PLUTONIUM AND AN ALKALI METAL

    Science.gov (United States)

    Seaborg, G.T.

    1960-08-01

    A method is given for precipitating alkali metal plutonium fluorides. such as KPuF/sub 5/, KPu/sub 2/F/sub 9/, NaPuF/sub 5/, and RbPuF/sub 5/, from an aqueous plutonium(IV) solution by adding hydrogen fluoride and alkali-metal- fluoride.

  8. 40 CFR 60.212 - Standard for fluorides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.212 Section... Industry: Superphosphoric Acid Plants § 60.212 Standard for fluorides. (a) On and after the date on which... facility any gases which contain total fluorides in excess of 5.0 g/megagram (Mg) of equivalent P2O5...

  9. 40 CFR 60.222 - Standard for fluorides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.222 Section... Industry: Diammonium Phosphate Plants § 60.222 Standard for fluorides. (a) On and after the date on which... facility any gases which contain total fluorides in excess of 30 g/megagram (Mg) of equivalent P2O5 feed...

  10. 40 CFR 60.242 - Standard for fluorides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.242 Section... Industry: Granular Triple Superphosphate Storage Facilities § 60.242 Standard for fluorides. (a) On and... atmosphere from any affected facility any gases which contain total fluorides in excess of 0.25...

  11. 40 CFR 60.232 - Standard for fluorides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.232 Section... Industry: Triple Superphosphate Plants § 60.232 Standard for fluorides. On and after the date on which the... gases which contain total fluorides in excess of 100 g/megagram (Mg) of equivalent P2O5 feed (0.20...

  12. Health effects of fluoride pollution caused by coal burning

    Energy Technology Data Exchange (ETDEWEB)

    Ando, M.; Tadano, M.; Yamamoto, S.; Tamura, K.; Chen, X. [Regional Environment Division, National Institute for Environmental Studies, Tsukuba, 305-0083 Ibaraki (Japan); Asanuma, S. [Japan Institute of Rural Medicine, Usuda, Nagano (Japan); Watanabe, T. [Saku Central Hospital, Usuda, Nagano (Japan); Kondo, T. [Matsumoto Dental College, Shiojiri, Nagano (Japan); Sakurai, S. [Otsuma Women' s University, Tama, Tokyo (Japan); Ji, R.; Liang, C.; Cao, S. [Institute of Environmental Health and Engineering, Beijing (China); Hong, Z. [Shanxi Maternity and Children' s Hospital, Taiyuan (China)

    2001-04-23

    Recently a huge amount of fluoride in coal has been released into indoor environments by the combustion of coal and fluoride pollution seems to be increasing in some rural areas in China. Combustion of coal and coal bricks is the primary source of gaseous and aerosol fluoride and these forms of fluoride can easily enter exposed food products and the human respiratory tract. Major human fluoride exposure was caused by consumption of fluoride contaminated food, such as corn, chilies and potatoes. For each diagnostic syndrome of dental fluorosis, a log-normal distribution was observed on the logarithm of urinary fluoride concentration in students in China. Urinary fluoride content was found to be a primary health indicator of the prevalence of dental fluorosis in the community. In the fluorosis areas, osteosclerosis in skeletal fluorosis patients was observed with a high prevalence. A biochemical marker of bone resorption, urinary deoxypyridinoline content was much higher in residents in China than in residents in Japan. It was suggested that bone resorption was stimulated to a greater extent in residents in China and fluoride may stimulate both bone resorption and bone formation. Renal function especially glomerular filtration rate was very sensitive to fluoride exposure. Inorganic phosphate concentrations in urine were significantly lower in the residents in fluorosis areas in China than in non-fluorosis area in China and Japan. Since airborne fluoride from the combustion of coal pollutes extensively both the living environment and food, it is necessary to reduce fluoride pollution caused by coal burning.

  13. Plasma processing of fluoride solutions of refractory rare metals

    Energy Technology Data Exchange (ETDEWEB)

    Gutsol, A.F. [Institute of Chemistry and Technology of Less-Common Elements and Raw Materials, Murmanskaya oblast` (Russian Federation)

    1995-09-01

    Features of plasma processing of fluoride solutions of refractory metals were studied. It was shown that pyrohydrolysis of niobium, tantalum, and titanium fluorides occurs in the gas phase, thus providing fine oxide powders. The pyrohydrolysis of low-volatility zirconium fluoride occurs in the solid phase, yielding oxide particles corresponding to the size of initial droplets.

  14. Onderzoek naar de bepaling van fluoride in een doorstroomsysteem

    NARCIS (Netherlands)

    Neele J; Nagtegaal-Wouterse GWM; Reijnders HFR

    1989-01-01

    Een snelle methode voor de bepaling van fluoride in een doorstroomsysteem met potentiometrische detectie en een lage onderste analysegrens is ontwikkeld. De mate waarin fluoride uit fluoride-verbindingen wordt vrijgemaakt door complexvormende stoffen is gevolgd om vast te stellen hoeveel tijd hierv

  15. Synthesis of reagents for fluoride technologies

    Institute of Scientific and Technical Information of China (English)

    Gordienko; P.; S.; Kolzunov; V.; A.; Dostovalov; V.; A.; Kaidalova; T.; A.

    2005-01-01

    Growing demand for fluorinating reagents to be used in rare-metal industry has stimulated conducting research in the field of production for these reagents. That is why the fluorinating reagents production has recently formed an independent segment of industry. Main industrial fluorinating reagents include hydrofluoric acid, anhydrous hydrogen fluoride, technical ammonium hydrodifluoride, fluorosilicic acid and its salts. To produce technical etching acid, fluor-spar with calcium fluoride content at least 92% is used in most cases. To produce anhydrous hydrogen fluoride, fluor-spar with calcium fluoride content 96 %-97 % is necessary. The fluorine-containing raw materials refinement from silica by means of flotation makes the fluorinating reagents production substantially more expensive. In this work we have attempted to process unconcentrated raw materials by fluorine removal in the form of volatile silicon tetrafluoride. In this process silicon tetrafluoride was recovered by liquid ammonia with subsequent hydrolysis of the formed ammonia hexafluorosilicate. Hydrolysis occurred according to the reaction:(NH4)2 SiF6 + 4NH3 + 2 H2O= 6NH4F+ SiO2 The products of the ammonia hexafluorosilicate hydrolysis included ammonia fluoride and amorphous silica gel ("white soot") as by-product. This "white soot" was of high purity-with main component content 99.95% and total admixture content 0.05%. Silica gel is a superfine material with specific surface of 267.6 m2/g and is recommended as filler in the production of rubber, plastics and for other applications.Ammonia fluoride was transformed into ammonia hydrodifluoride (main processing product) according to the reaction:2NH4F→NH3+NH4 HF2 It was stated that the NH4F: NH4 HF2 ratio depends on boiling point temperature-with its increase the ammonia hydrofluoride concentration in solution increases as well.

  16. Enhanced fluoride sorption by mechanochemically activated kaolinites.

    Science.gov (United States)

    Meenakshi, S; Sundaram, C Sairam; Sukumar, Rugmini

    2008-05-01

    Kaolinite clay obtained from the mines was processed and studied for its fluoride sorption capacity. The surface area of the clay mineral was increased from 15.11 m(2)/g (raw) to 32.43 m(2)/g (activated) by mechanochemical activation. Batch adsorption studies were conducted to optimize various equilibrating conditions like the effect of contact time, dosage, pH for both raw and micronized kaolinites (RK and MK). The effect of other interfering anions on the defluoridation capacity (DC) of the sorbents was studied. Sorption of fluoride by the sorbents was observed over a wide pH range of 3-11. The studies revealed there is an enhanced fluoride sorption on MK. FTIR and XRD were used for the characterization of the sorbent. The surface morphology of the clay material was observed using SEM. The adsorption of fluoride was studied at three different temperatures, viz., 303, 313 and 323 K. The sorption data obtained at optimized conditions were subjected to Freundlich and Langmuir isotherms. Sorption intensity (1/n) (0.770-0.810) has been evaluated using Freundlich isotherm, whereas the values of sorption capacity Q(0) (0.609, 0.714 and 0.782 mg/g) and binding energy b (0.158, 0.145 and 0.133 L/mg) at three different temperatures have been estimated using Langmuir isotherm. Adsorption process was found to be controlled by both Freundlich and Langmuir isotherms. Thermodynamic studies revealed that the sorption of fluoride on MK is endothermic and a spontaneous process. The kinetic studies indicate that the sorption of fluoride on MK follows pseudo-first-order and intraparticle diffusion models.

  17. Enhanced fluoride sorption by mechanochemically activated kaolinites

    Energy Technology Data Exchange (ETDEWEB)

    Meenakshi, S. [Department of Chemistry, Gandhigram Rural University, Gandhigram 624302, Tamilnadu (India)], E-mail: drs_meena@rediffmail.com; Sundaram, C. Sairam [Department of Science and Humanities, Karaikal Polytechnic College, Karaikal 609609, Puducherry (India); Sukumar, Rugmini [Chemical Sciences and Technologies, Regional Research Laboratory, Trivandrum 695019, Kerala (India)

    2008-05-01

    Kaolinite clay obtained from the mines was processed and studied for its fluoride sorption capacity. The surface area of the clay mineral was increased from 15.11 m{sup 2}/g (raw) to 32.43 m{sup 2}/g (activated) by mechanochemical activation. Batch adsorption studies were conducted to optimize various equilibrating conditions like the effect of contact time, dosage, pH for both raw and micronized kaolinites (RK and MK). The effect of other interfering anions on the defluoridation capacity (DC) of the sorbents was studied. Sorption of fluoride by the sorbents was observed over a wide pH range of 3-11. The studies revealed there is an enhanced fluoride sorption on MK. FTIR and XRD were used for the characterization of the sorbent. The surface morphology of the clay material was observed using SEM. The adsorption of fluoride was studied at three different temperatures, viz., 303, 313 and 323 K. The sorption data obtained at optimized conditions were subjected to Freundlich and Langmuir isotherms. Sorption intensity (1/n) (0.770-0.810) has been evaluated using Freundlich isotherm, whereas the values of sorption capacity Q{sup 0} (0.609, 0.714 and 0.782 mg/g) and binding energy b (0.158, 0.145 and 0.133 L/mg) at three different temperatures have been estimated using Langmuir isotherm. Adsorption process was found to be controlled by both Freundlich and Langmuir isotherms. Thermodynamic studies revealed that the sorption of fluoride on MK is endothermic and a spontaneous process. The kinetic studies indicate that the sorption of fluoride on MK follows pseudo-first-order and intraparticle diffusion models.

  18. Vaporization kinetics of Sb2S3 in argon fluid

    Institute of Scientific and Technical Information of China (English)

    杨勇; 华一新

    2003-01-01

    The vaporization kinetics of antimony trisulfide in argon fluid was studied with thermogravimetry at 873- 1 173 K. A theoretical model was developed to calculate the overall rate constant and the mass transfer coefficient ingas phase. The experimental results show that the vaporization rate is enhanced with increasing temperature and ar-gon flow-rate. The evaporation rate is mainly controlled by mass transport in the gas phase. The apparent activationenergy for the process is found to be 55.54 kJ/mol. It is demonstrated that the mass transfer coefficient in gas phaseis decreased with increasing temperature.

  19. Modelling of a supersonic ICP argon-hydrogen expansion

    International Nuclear Information System (INIS)

    An expanding argon-hydrogen plasma is investigated by means of simulations. The model is a hydrodynamical model specific for plasma expansions, taking into account the conservation laws of mass, momentum and energy. The code includes the Rankine-Hugoniot relations to calculate shock jump conditions. Results are shown for the expansion from an inductively coupled plasma (ICP) with a separated Laval nozzle. The expansion discussed here is a 'weakly' under-expanding argon-hydrogen plasma. The results from the ICP expansion are verified with probe measurements

  20. Attosecond-correlated dynamics of two electrons in argon

    Indian Academy of Sciences (India)

    V Sharma; N Camus; B Fischer; M Kremer; A Rudenko; B Bergues; M Kuebel; N G Johnson; M F Kling; T Pfeifer; J Ullrich; R Moshammer

    2014-01-01

    In this work we explored strong field-induced decay of doubly excited transient Coulomb complex Ar** → Ar2++2. We measured the correlated two-electron emission as a function of carrier envelop phase (CEP) of 6 fs pulses in the non-sequential double ionization (NSDI) of argon. Classical model calculations suggest that the intermediate doubly excited Coulomb complex loses memory of its formation dynamics. We estimated the ionization time difference between the two electrons from NSDI of argon and it is 200 ± 100 as (N Camus et al, Phys. Rev. Lett. 108, 073003 (2012)).

  1. Reconstructing temporal variation of fluoride uptake in eastern grey kangaroos (Macropus giganteus) from a high-fluoride area by analysis of fluoride distribution in dentine.

    Science.gov (United States)

    Kierdorf, Horst; Rhede, Dieter; Death, Clare; Hufschmid, Jasmin; Kierdorf, Uwe

    2016-04-01

    Trace element profiling in the incrementally formed dentine of mammalian teeth can be applied to reconstruct temporal variation of incorporation of these elements into the tissue. Using an electron microprobe, this study analysed fluoride distribution in dentine of first and third mandibular molars of free-ranging eastern grey kangaroos inhabiting a high-fluoride area, to assess temporal variation in fluoride uptake of the animals. Fluoride content in the early-formed dentine of first molars was significantly lower than in the late-formed dentine of these teeth, and was also lower than in both, the early and the late-formed dentine of third molars. As early dentine formation in M1 takes place prior to weaning, this finding indicates a lower dentinal fluoride uptake during the pre-weaning compared to the post-weaning period. This is hypothetically attributed to the action of a partial barrier to fluoride transfer from blood to milk in lactating females and a low bioavailability of fluoride ingested together with milk. Another factor contributing to lower plasma fluoride levels in juveniles compared to adults is the rapid clearance of fluoride from blood plasma in the former due to their intense skeletal growth. The combined action of these mechanisms is considered to explain why in kangaroos from high-fluoride areas, the (early-formed) first molars are not affected by dental fluorosis while the (later-formed) third and fourth molars regularly exhibit marked to severe fluorotic lesions. PMID:26736058

  2. Comparative evaluation of fluoride release from PRG-composites and compomer on application of topical fluoride: An in-vitro study

    Directory of Open Access Journals (Sweden)

    Dhull K

    2009-03-01

    Full Text Available Aims and Objective: To determine the fluoride release from Giomer and Compomer, using different topical fluoride regimes, and to compare the amount of fluoride release from giomer with that of compomer. Materials and Method: Forty-eight specimens of each giomer and compomer were divided into four treatment groups, namely, control group, fluoridated dentifrice (500 ppm once daily group, fluoridated dentifrice (500 ppm twice daily group, fluoridated dentifrice (500 ppm once daily + fluoridated mouthwash (225 ppm group. Each specimen was suspended in demineralizing solution for six hours and remineralizing solution for 18 hours. Fluoride release was measured in both the demineralizing solution and remineralizing solution daily for seven days. Total daily fluoride release for each specimen was calculated by adding the amount released in the demineralizing solution to that released in remineralizing solution. Results and Conclusion: The fluoride release (ppm was found to be more in Giomer when compared to Compomer. The fluoride released from Giomer and Compomer was significantly greater in the acidic demineralizing solution than in the neutral remineralizing solution. It was found that increasing fluoride exposure significantly increased fluoride release from the giomer and compomer. It was found that the fluoride release from the subgroups of giomer and compomer was in the following order: fluoridated dentifrice twice daily > fluoridated dentifrice once daily + fluoridated mouthwash > fluoridated dentifrice once daily > control group. It was found that the giomer showed a greater fluoride uptake than the compomer.

  3. Some electronic and magnetic properties of Fluoride ion in Fluoride structure nanocrystals

    Science.gov (United States)

    Imtani, Ali Nasir

    2012-01-01

    We have investigated the effects of the environment potential around Fluoride ion on some important electronic and magnetic properties such as dipole polarisability, moment of oscillator strengths S(k) and magnetic susceptibility. The theoretical procedure is based on the variational-perturbation theory with two parameter trial functions incorporated in an ionic model. We estimate these properties in four cases for Fluoride ion; free ion, ion under different potentials, ion in the crystals and ion in nanocrystal, CdF2, CaF2, PbF2, SrF2 and BaF2. Our results indicate that these properties vary with ion environments and the free state of Fluoride ion has higher values and there is linearity behaviour of these properties with lattice constant. For Fluoride ion in nanocrystal, we have found that there is an extra parameter that can also affect the dipole polarisability, the number of ions in the structure.

  4. Fluoride in Drinking Water -Its Effects and Removal

    Directory of Open Access Journals (Sweden)

    Ram Gopal

    1985-01-01

    Full Text Available Occurrence of fluoride in water, its metabolism, excretion. effect oingestion in human and cattle system and methods of fluoridation and defluoridation have been discussed. The presence of fluoride in waters occurring in India, with special reference to Rajasthan desert has been reviewed. Based on the survey and physico-chemical analyses of about 2,700 water samples of Rajasthan, distribution of fluoride in this area has been discussed wrth reference to drinking water standards. A water resources map showing concentrations of fluoride in four arid districts of Rajasthan is also presented.

  5. Oral Fluoride Including Drinking Water in Prevention of Tooth Decay

    OpenAIRE

    Vitoria I

    2015-01-01

    Herein we present a review of the role of oral fluoride in the prevention of tooth decay, together with updated recommendations on fluoride supplements. Fluoridation of public drinking water is still considered effective, but the recommended level of fluoride is now 0.7 mg/L, compared with the previously recommended range of 0.7-1.2 mg/L. Oral fluoride supplements are currently not restricted to the children at high risk for tooth decay, but recommended initiate at 6 months&nbs...

  6. Fluoride: a risk factor for inflammatory bowel disease?

    Science.gov (United States)

    Follin-Arbelet, Benoit; Moum, Bjørn

    2016-09-01

    Although the association between inflammatory bowel disease (IBD) and oral hygiene has been noticed before, there has been little research on prolonged fluoride exposure as a possible risk factor. In the presented cases, exposure to fluoride seems indirectly associated with higher incidence of IBD. Fluoride toxicology and epidemiology documents frequent unspecific chronic gastrointestinal symptoms and intestinal inflammation. Efflux genes that confer resistance to environmental fluoride may select for IBD associated gut microbiota and therefore be involved in the pathogenesis. Together these multidisciplinary results argue for further investigation on the hypothesis of fluoride as a risk factor for IBD. PMID:27199224

  7. Manufacture of high purity low arsenic anhydrous hydrogen fluoride

    International Nuclear Information System (INIS)

    A process for manufacturing anhydrous hydrogen fluoride with reduced levels of arsenic impurity from arsenic contaminated anhydrous hydrogen fluoride is described which comprises: (a) contacting the anhydrous hydrogen fluoride with an effective amount of hydrogen peroxide to oxidize the arsenic impurity in the presence of a catalyst which comprises a catalytic amount of (i) molybdenum or an inorganic molybdenum compound and (ii) a phosphate compound, at a temperature and for a period of time sufficient to oxidize volatile trivalent arsenic impurities in the anhydrous hydrogen fluoride to non-volatile pentavalent arsenic compounds, and (b) distilling the resulting mixture and recovering anhydrous hydrogen fluoride with reduced levels of arsenic impurity

  8. Uranium-liquid argon calorimetry: preliminary results from the DO tests

    International Nuclear Information System (INIS)

    The motivations for using uranium and liquid argon in sampling calorimetry are reviewed and the pros and cons of the technique are discussed. Preliminary results of the DO uranium-liquid argon test program are presented. 9 refs., 7 figs

  9. Total Fluoride Intake by Children from a Tropical Brazilian City.

    Science.gov (United States)

    Lima, Carolina V; Cury, Jaime A; Vale, Glauber C; Lima, Marina D M; Moura, Lúcia de Fátima A D; Moura, Marcoeli Silva de

    2015-01-01

    The main sources of fluoride intake by children are fluoridated water and toothpaste. Little has been studied regarding fluoride intake from these sources in regions with tropical climates and high temperatures throughout the year. This study aimed to determine the amount of fluoride ingested from diet and tooth brushing by children who live in a city with a tropical climate. Sixty-seven children from Teresina, Piauí, Brazil, took part in this study. The city's water supply was optimally fluoridated. The duplicate-diet method was used to determine the fluoride intake from diet. The intake of fluoride from dentifrice was determined by subtracting the amount of fluoride placed on the toothbrush and that recovered after brushing. The concentration of fluoride was measured using an ion-specific electrode and is expressed as milligrams/kilogram of body weight/day. The mean (±SD) total amount was 0.071 ± 0.036 mg F/kg body weight/day, and the relative contributions of diet and toothpaste were 0.025 ± 0.010 and 0.046 ± 0.035, respectively. The factors associated with fluoride intake from toothpaste were: use of children's toothpaste (p = 0.003), use of large amounts of toothpaste (p fluorosis risk. The results suggest that the amount of fluoride ingested by most children who live in a Brazilian city with a tropical climate is considered safe in terms of the risk of dental fluorosis. PMID:26655142

  10. Optical emission spectroscopy of argon and hydrogen-containing plasmas

    Science.gov (United States)

    Siepa, Sarah; Danko, Stephan; Tsankov, Tsanko V.; Mussenbrock, Thomas; Czarnetzki, Uwe

    2015-09-01

    Optical emission spectroscopy (OES) on neutral argon is applied to investigate argon, hydrogen and hydrogen-silane plasmas. The spectra are analyzed using an extensive collisional-radiative model (CRM), from which the electron density and the electron temperature (or mean energy) can be calculated. The CRM also yields insight into the importance of different excited species and kinetic processes. The OES measurements are performed on pure argon plasmas at intermediate pressure. Besides, hydrogen and hydrogen-silane plasmas are investigated using argon as a trace gas. Especially for the gas mixture discharges, CRMs for low and high pressure differ substantially. The commonly used line-ratio technique is found to lose its sensitivity for gas mixture discharges at higher pressure. A solution using absolutely calibrated line intensities is proposed. The effect of radiation trapping and the shape of the electron energy distribution function on the results are discussed in detail, as they have been found to significantly influence the results. This work was supported by the Ruhr University Research School PLUS, funded by Germany's Excellence Initiative [DFG GSC 98/3].

  11. Measurement of the argon plasma temperature by use of pyrometer

    International Nuclear Information System (INIS)

    The author describes in detail how to use pyrometer to measure the plasma temperature. The temperatures of shock-generated argon plasmas are given in the present work. Measured results of temperature-pressure curve are compared with calculated results using Saha-Debye-Huckel model, which are in good agreement

  12. Turbulence and transport in a magnetized argon plasma

    International Nuclear Information System (INIS)

    An experimental study on turbulence and transport in the highly ionized argon plasma of a hollow cathode discharge is described. In order to determine the plasma parameters three standard diagnostics have been used, whilst two diagnostics have been developed to study the plasma turbulence. (Auth.)

  13. Thermophysical properties of multi-shock compressed dense argon.

    Science.gov (United States)

    Chen, Q F; Zheng, J; Gu, Y J; Chen, Y L; Cai, L C; Shen, Z J

    2014-02-21

    In contrast to the single shock compression state that can be obtained directly via experimental measurements, the multi-shock compression states, however, have to be calculated with the aid of theoretical models. In order to determine experimentally the multiple shock states, a diagnostic approach with the Doppler pins system (DPS) and the pyrometer was used to probe multiple shocks in dense argon plasmas. Plasma was generated by a shock reverberation technique. The shock was produced using the flyer plate impact accelerated up to ∼6.1 km/s by a two-stage light gas gun and introduced into the plenum argon gas sample, which was pre-compressed from the environmental pressure to about 20 MPa. The time-resolved optical radiation histories were determined using a multi-wavelength channel optical transience radiance pyrometer. Simultaneously, the particle velocity profiles of the LiF window was measured with multi-DPS. The states of multi-shock compression argon plasma were determined from the measured shock velocities combining the particle velocity profiles. We performed the experiments on dense argon plasmas to determine the principal Hugonoit up to 21 GPa, the re-shock pressure up to 73 GPa, and the maximum measure pressure of the fourth shock up to 158 GPa. The results are used to validate the existing self-consistent variational theory model in the partial ionization region and create new theoretical models. PMID:24559345

  14. Thermal decomposition of Yttrium(III) isovalerate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Tang, Xiao;

    2016-01-01

    The thermal behaviour of yttrium(III) isovalerate (Y(C4H9CO2)3) was studied in argon by means of thermogravimetry, differential thermal analysis, FTIR-spectroscopy, hot-stage optical microscopy and X-ray diffraction with a laboratory Cu-tube source as well as with a synchrotron radiation source...

  15. Thermal decomposition of yttrium(III) valerate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Tang, Xiao;

    2014-01-01

    The thermal decomposition of yttrium(III) valerate (Y(C4H9CO2)3) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction, in-situ synchrotron diffraction and hot-stage microscopy as well as room temperature optical microscopy. Melting...

  16. Thermal decomposition of yttrium(III) hexanoate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Suarez Guevara, Maria Josefina; Attique, Fahmida;

    2015-01-01

    The thermal decomposition of yttrium(III) hexanoate (Y(C5H11CO2)3)·xH2O in argon was studied by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction at a laboratory Cu-tube source and in-situ experiments at a synchrotron radiation source as well as hot...

  17. A 2-Dimensional Fluid Model for an Argon Rf Discharge

    NARCIS (Netherlands)

    Passchier, J. D. P.; W. J. Goedheer,

    1993-01-01

    A fluid model for an argon rf discharge in a cylindrical discharge chamber is presented. The model contains the particle balances for electrons and ions and the electron energy balance. A nonzero autobias voltage is obtained by imposing the condition that the time-averaged current toward the powered

  18. Study of Liquid Argon Dopants for LHC Hadron Calorimetry

    CERN Multimedia

    2002-01-01

    Hadron calorimetry based on the Liquid Argon Ionisation Chamber technique is one of the choice techniques for LHC-experimentation. A systematic study of the effect of selected dopants on Liquid Argon (LAr) will be carried out with the aim to achieve an improvement on: \\item (i)~``Fast Liquid Argon'' search and study of dopants to increase the drift velocity. It has been already shown that CH&sub4. added at a fraction of one percent increases the drift velocity by a factor of two or more. \\item (ii)~``Compensated Liquid Argon'' search and study of dopants to increase the response to densely ionising particles, resulting in improved compensation, such as photosensitive dopants. \\end{enumerate}\\\\ \\\\ Monitoring of the parameters involved in understanding the response of a calorimeter is essential. In case of doped LAr, the charge yield, the non-saturated drift velocity and the electron lifetime in the liquid should be precisely and simultaneously monitored as they all vary with the level of dopant concentrati...

  19. LArGe. A liquid argon scintillation veto for GERDA

    International Nuclear Information System (INIS)

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 103 have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10-2 cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural 42Ar abundance (in parallel to Gerda), and have indication for the 2νββ-decay in natural germanium. (orig.)

  20. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  1. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  2. Estimation of atmospheric fluoride by limed filter papers

    International Nuclear Information System (INIS)

    The limed filter paper method of static sampling of atmospheric fluoride is reviewed in this report. Use of the technique, in conjunction with precise measurement of the absorbed fluoride and calibration with dynamic air sampling techniques, to estimate atmospheric fluoride levels, is considered to give only qualitative data (± 50%). The limed filter paper method is site specific due to variations in meteorological conditions. Its main value is to indicate seasonal and annual trends in fluoride exposure of vegetation. Subject to these considerations, the lower and upper limits of atmospheric fluoride exposure and the applicability to atmospheric fluoride estimation under routine or emergency fluoride release conditions are discussed, with special emphasis on the limiting factors

  3. FLUORIDE CONTENT OF COMMERCIALLY AVAILABLE SOY MILK PRODUCTS IN THAILAND.

    Science.gov (United States)

    Rirattanapong, Opas; Rirattanapong, Praphasri

    2016-01-01

    Abstract. In Thailand, the consumption of soy milk products is common but there is limited data about their fluoride content. The purpose of this study was to es- timate the fluoride content of soy milk products available in Thailand. Fluoride content was determined for 76 brands of soy milk using a F-ion-specific electrode. The fluoride concentrations ranged from 0.01 to 3.78 μg/ml. The fluoride content was not related to sugar content, soy bean content or the sterilization process. Among 3 brands of soy milk containing tea powder extract, the fluoride content was high (1.25 to 3.78 μg/ml). Most brands of soy milk tested in our study had fluoride content below the optimal daily intake but brands containing tea powder extract if consumed by children may increase their risk for fluorosis. PMID:27086437

  4. Fluoride in the prey of barn owls (Tyto alba).

    Science.gov (United States)

    Thomson, A G

    1987-01-01

    Bone fluoride in short-tailed voles (Microtus agrestis) and common shrews (Sorex araneus), the prey of barn owls (Tyto alba), was studied on Anglesey, North Wales. The average fluoride content of M. agrestis skulls obtained from a location 0.9 km from an aluminium reduction plant was significantly greater than that of skulls from another location 22 km from the source of industrial fluoride pollution. At both locations, mean fluoride levels of skulls extracted from owl pellets and those of voles trapped mechanically were broadly similar but important differences existed. Near the aluminium reduction plant, owls caught voles and shrews with a much wider range of fluoride levels than occurred at a single trapping site. However, there was no evidence for selection of heavily fluoridated prey. Within 1 km of the aluminium reduction plant, six trapping sites yielded S. araneus with a fourfold difference between the highest and lowest mean bone fluoride level. PMID:15092770

  5. Estimated Fluoride Doses from Toothpastes Should be Based on Total Soluble Fluoride

    Directory of Open Access Journals (Sweden)

    Jaime A. Cury

    2013-11-01

    Full Text Available The fluoride dose ingested by young children may be overestimated if based on levels of total fluoride (TF rather than levels of bioavailable fluoride (total soluble fluoride—TSF in toothpaste. The aim of the present study was to compare doses of fluoride intake based on TF and TSF. Fluoride intake in 158 Brazilian children aged three and four years was determined after tooth brushing with their usual toothpaste (either family toothpaste (n = 80 or children’s toothpaste (n = 78. The estimated dose (mg F/day/Kg of body weight of TF or TSF ingested was calculated from the chemical analysis of the toothpastes. Although the ingested dose of TF from the family toothpastes was higher than that from the children’s toothpastes (0.074 ± 0.007 and 0.039 ± 0.003 mg F/day/Kg, respectively; p 0.05. The fluoride dose ingested by children from toothpastes may be overestimated if based on the TF of the product. This finding suggests that the ingested dose should be calculated based on TSF. Dose of TSF ingested by children is similar whether family or children’s toothpaste is used.

  6. Solid electrolytes for fluoride ion batteries: ionic conductivity in polycrystalline tysonite-type fluorides.

    Science.gov (United States)

    Rongeat, Carine; Reddy, M Anji; Witter, Raiker; Fichtner, Maximilian

    2014-02-12

    Batteries based on a fluoride shuttle (fluoride ion battery, FIB) can theoretically provide high energy densities and can thus be considered as an interesting alternative to Li-ion batteries. Large improvements are still needed regarding their actual performance, in particular for the ionic conductivity of the solid electrolyte. At the current state of the art, two types of fluoride families can be considered for electrolyte applications: alkaline-earth fluorides having a fluorite-type structure and rare-earth fluorides having a tysonite-type structure. As regard to the latter, high ionic conductivities have been reported for doped LaF3 single crystals. However, polycrystalline materials would be easier to implement in a FIB due to practical reasons in the cell manufacturing. Hence, we have analyzed in detail the ionic conductivity of La(1-y)Ba(y)F(3-y) (0 ≤ y ≤ 0.15) solid solutions prepared by ball milling. The combination of DC and AC conductivity analyses provides a better understanding of the conduction mechanism in tysonite-type fluorides with a blocking effect of the grain boundaries. Heat treatment of the electrolyte material was performed and leads to an improvement of the ionic conductivity. This confirms the detrimental effect of grain boundaries and opens new route for the development of solid electrolytes for FIB with high ionic conductivities. PMID:24444763

  7. Actinide measurements by AMS using fluoride matrices

    Science.gov (United States)

    Cornett, R. J.; Kazi, Z. H.; Zhao, X.-L.; Chartrand, M. G.; Charles, R. J.; Kieser, W. E.

    2015-10-01

    Actinides can be measured by alpha spectroscopy (AS), mass spectroscopy or accelerator mass spectrometry (AMS). We tested a simple method to separate Pu and Am isotopes from the sample matrix using a single extraction chromatography column. The actinides in the column eluent were then measured by AS or AMS using a fluoride target matrix. Pu and Am were coprecipitated with NdF3. The strongest AMS beams of Pu and Am were produced when there was a large excess of fluoride donor atoms in the target and the NdF3 precipitates were diluted about 6-8 fold with PbF2. The measured concentrations of 239,240Pu and 241Am agreed with the concentrations in standards of known activity and with two IAEA certified reference materials. Measurements of 239,240Pu and 241Am made at A.E. Lalonde AMS Laboratory agree, within their statistical uncertainty, with independent measurements made using the IsoTrace AMS system. This work demonstrated that fluoride targets can produce reliable beams of actinide anions and that the measurement of actinides using fluorides agree with published values in certified reference materials.

  8. Conversion of an atomic to a molecular argon ion and low pressure argon relaxation

    Science.gov (United States)

    M, N. Stankov; A, P. Jovanović; V, Lj Marković; S, N. Stamenković

    2016-01-01

    The dominant process in relaxation of DC glow discharge between two plane parallel electrodes in argon at pressure 200 Pa is analyzed by measuring the breakdown time delay and by analytical and numerical models. By using the approximate analytical model it is found that the relaxation in a range from 20 to 60 ms in afterglow is dominated by ions, produced by atomic-to-molecular conversion of Ar+ ions in the first several milliseconds after the cessation of the discharge. This conversion is confirmed by the presence of double-Gaussian distribution for the formative time delay, as well as conversion maxima in a set of memory curves measured in different conditions. Finally, the numerical one-dimensional (1D) model for determining the number densities of dominant particles in stationary DC glow discharge and two-dimensional (2D) model for the relaxation are used to confirm the previous assumptions and to determine the corresponding collision and transport coefficients of dominant species and processes. Project supported by the Ministry of Education, Science and Technological Development of the Republic of Serbia (Grant No. ON171025).

  9. Observations of acoustic-wave-induced superluminescence in an argon plasma

    International Nuclear Information System (INIS)

    It is shown that in an argon discharge plasma it is possible to obtain overpopulation of certain electronic levels of atomic argon under the influence of acoustic waves. When the specified threshold is exceeded, then a superluminescence (in the form of light flashes) from the overpopulated electronic levels of atomic argon is observed

  10. 21 CFR 874.4490 - Argon laser for otology, rhinology, and laryngology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon laser for otology, rhinology, and laryngology. 874.4490 Section 874.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Argon laser for otology, rhinology, and laryngology. (a) Identification. The argon laser device for...

  11. Water fluoridation in 40 Brazilian cities: 7 year analysis

    Directory of Open Access Journals (Sweden)

    Suzely Adas Saliba MOIMAZ

    2013-01-01

    Full Text Available Objectives Fluoride levels in the public water supplies of 40 Brazilian cities were analyzed and classified on the basis of risk/benefit balance. Material and Methods Samples were collected monthly over a seven-year period from three sites for each water supply source. The samples were analyzed in duplicate in the laboratory of the Center for Research in Public Health - UNESP using an ion analyzer coupled to a fluoride-specific electrode. Results A total of 19,533 samples were analyzed, of which 18,847 were artificially fluoridated and 686 were not artificially fluoridated. In samples from cities performing water fluoridation, 51.57% (n=9,720 had fluoride levels in the range of 0.55 to 0.84 mg F/L; 30.53% (n=5,754 were below 0.55 mg F/L and 17.90% (n=3,373 were above 0.84 mg F/L (maximum concentration=6.96 mg F/L. Most of the cities performing fluoridation that had a majority of samples with fluoride levels above the recommended parameter had deep wells and more than one source of water supply. There was some variability in the fluoride levels of samples from the same site and between collection sites in the same city. Conclusions The majority of samples from cities performing fluoridation had fluoride levels within the range that provides the best combination of risks and benefits, minimizing the risk of dental fluorosis while preventing dental caries. The conduction of studies about water distribution systems is suggested in cities with high natural fluoride concentrations in order to optimize the use of natural fluoride for fluoridation costs and avoid the risk of dental fluorosis.

  12. Effects of fluoridated milk on root dentin remineralization.

    Directory of Open Access Journals (Sweden)

    Wolfgang H Arnold

    Full Text Available The prevalence of root caries is increasing with greater life expectancy and number of retained teeth. Therefore, new preventive strategies should be developed to reduce the prevalence of root caries. The aim of this study was to investigate the effects of fluoridated milk on the remineralization of root dentin and to compare these effects to those of sodium fluoride (NaF application without milk.Thirty extracted human molars were divided into 6 groups, and the root cementum was removed from each tooth. The dentin surface was demineralized and then incubated with one of the following six solutions: Sodium chloride NaCl, artificial saliva, milk, milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Serial sections were cut through the lesions and investigated with polarized light microscopy and quantitative morphometry, scanning electron microscopy (SEM and energy-dispersive X-ray spectroscopy (EDS. The data were statistically evaluated using a one-way ANOVA for multiple comparisons.The depth of the lesion decreased with increasing fluoride concentration and was the smallest after incubation with artificial saliva+10 ppm fluoride. SEM analysis revealed a clearly demarcated superficial remineralized zone after incubation with milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Ca content in this zone increased with increasing fluoride content and was highest after artificial saliva+10 ppm fluoride incubation. In the artificial saliva+10 ppm fluoride group, an additional crystalline layer was present on top of the lesion that contained elevated levels of F and Ca.Incubation of root dentin with fluoridated milk showed a clear effect on root dentin remineralization, and incubation with NaF dissolved in artificial saliva demonstrated a stronger effect.

  13. Argon metastable dynamics and lifetimes in a direct current microdischarge

    Science.gov (United States)

    Stefanović, Ilija; Kuschel, Thomas; Schröter, Sandra; Böke, Marc

    2014-09-01

    In this paper we study the properties of a pulsed dc microdischarge with the continuous flow of argon. Argon metastable lifetimes are measured by tunable diode laser absorption spectroscopy (TDLAS) and are compared with calculated values which yield information about excitation and de-excitation processes. By increasing the gas flow-rate about 5 times from 10 to 50 sccm, the Arm lifetime increases from 1 to 5 μs due to the reduction of metastable quenching with gas impurities. Optical emission spectroscopy reveals nitrogen and water molecules as the main gas impurities. The estimated N2 density [N2] = 0.1% is too low to explain the measured metastable lifetimes. Water impurity was found to be the main de-excitation source of argon metastable atoms due to high quenching coefficients. The water impurity level of [H2O] = 0.15% to 1% is sufficient to bring calculated metastable lifetimes in line with experiments. The maximum value of water content in the discharge compared to the argon atoms is estimated to approximately 6%, due to the large surface to volume ratio of the microdischarge. The current pulse releases the water molecules from the electrode surface and they are either re-adsorbed in the time between 0.4 ms for [H2O] = 1% and 2.6 ms for [H2O] = 0.15% or pumped out of the discharge with the speed equal to the gas flow-rate. Depending on its partial pressure, the water impurity re-adsorption time is of the order of magnitude or less then the argon gas residence time.

  14. Fluoride uptake into the developing enamel and dentine of sheep incisors following daily ingestion of fluoridated milk or water

    International Nuclear Information System (INIS)

    The caries preventive action of fluoride is common knowledge, although some of the mechanisms involved remain equivocal. At present, raised local levels of fluoride at, or in, the surface of tooth enamel is the most commonly accepted explanation of the anti-cariogenic action of fluoride. However, fluoride incorporated as fluorapatite into the tooth during its formation remains a possible alternative or complementary anti-cariogenic mechanism. If so, regular ingestion of fluoride during tooth formation is beneficial. Although use of fluoridated water is the preferred method in public health programmes, access to suitable potable water is required, and often this in not feasible. Fresh, preserved, or dried cow's milk products are widely used as nutritional and dietary items in most populations, particularly for young children. Milk is a practical, controllable means for regular delivery of fluoride. Processing of milk is commonly centralised and uses standardised conditions, allowing easy supplementation of fluoride for distribution to communities. The purpose of this study was to resolve the question of availability of fluoride ingested in milk compared with fluoride ingested in water by measuring fluoride deposition in the developing permanent incisors of young sheep. Incisors were analysed using a proton microprobe. (author). 18 refs., 1 tabs., 3 figs

  15. Water Fluoridation: A Critical Review of the Physiological Effects of Ingested Fluoride as a Public Health Intervention

    Directory of Open Access Journals (Sweden)

    Stephen Peckham

    2014-01-01

    Full Text Available Fluorine is the world’s 13th most abundant element and constitutes 0.08% of the Earth crust. It has the highest electronegativity of all elements. Fluoride is widely distributed in the environment, occurring in the air, soils, rocks, and water. Although fluoride is used industrially in a fluorine compound, the manufacture of ceramics, pesticides, aerosol propellants, refrigerants, glassware, and Teflon cookware, it is a generally unwanted byproduct of aluminium, fertilizer, and iron ore manufacture. The medicinal use of fluorides for the prevention of dental caries began in January 1945 when community water supplies in Grand Rapids, United States, were fluoridated to a level of 1 ppm as a dental caries prevention measure. However, water fluoridation remains a controversial public health measure. This paper reviews the human health effects of fluoride. The authors conclude that available evidence suggests that fluoride has a potential to cause major adverse human health problems, while having only a modest dental caries prevention effect. As part of efforts to reduce hazardous fluoride ingestion, the practice of artificial water fluoridation should be reconsidered globally, while industrial safety measures need to be tightened in order to reduce unethical discharge of fluoride compounds into the environment. Public health approaches for global dental caries reduction that do not involve systemic ingestion of fluoride are urgently needed.

  16. Effective use of fluorides for the prevention of dental caries in the 21st century

    DEFF Research Database (Denmark)

    Petersen, Poul Erik; Lennon, Michael A

    2004-01-01

    , due to changing living conditions and dietary habits, and inadequate exposure to fluorides. Research on the oral health effects of fluoride started around 100 years ago; the focus has been on the link between water and fluorides and dental caries and fluorosis, topical fluoride applications, fluoride...

  17. EFFECTS OF ARGON ON THE PROPERTIES OF RF SPUTTERED AMORPHOUS SILICON

    OpenAIRE

    Shao-Qi, Peng; Qai, Yu; Xian, Zhang; Jing, Ye

    1981-01-01

    The Effects of argon on the properties of rf sputtered amorphous silicon film have been investigated. As the sputtering argon pressure is increased from 2 to 20 mTorr, the content of argon in the amorphous silicon film increases apparently (Argon/Silicon : from 10-2 to 5 x 10-2). The other properties measured as a function of argon pressure PAr show that as the PAr is increased, the photoconductivity, resistivity (300K), conductivity activation energy and optical gap increase also, while the ...

  18. Fluoride content of clay minerals and argillaceous earth materials

    Science.gov (United States)

    Thomas, J., Jr.; Glass, H.D.; White, W.A.; Trandel, R.M.

    1977-01-01

    A reliable method, utilizing a fluoride ion-selective electrode, is described for the determination of fluoride in clays and shales. Interference by aluminum and iron is minimal. The reproducibility of the method is about ??5% at different levels of fluoride concentration. Data are presented for various clay minerals and for the clays and shales. Fluoride values range from 44 ppm (0.0044%) for nontronite from Colfax, WA, to 51,800 ppm (5.18%) for hectorite from Hector, CA. In general, clays formed under hydrothermal conditions are relatively high in fluoride content, provided the hydrothermal waters are high in fluoride content. Besides hectorite, dickite from Ouray, CO, was found to contain more than 50 times as much fluoride (6700 ppm) as highly crystalline geode kaolinite (125 ppm). The clay stratum immediately overlying a fluorite mineralized zone in southern Illinois was found to have a higher fluoride content than the same stratum in a nonmineralized zone approximately 1 mile away. Nonmarine shales in contact with Australian coals were found to be lower in fluoride content than were marine shales in contact with Illinois coals. It is believed that, in certain instances, peak shifts on DTA curves of similar clay minerals are the result of significant differences in their fluoride content. ?? 1977.

  19. Arsenic from community water fluoridation: quantifying the effect.

    Science.gov (United States)

    Peterson, Emily; Shapiro, Howard; Li, Ye; Minnery, John G; Copes, Ray

    2016-04-01

    Community water fluoridation is a WHO recommended strategy to prevent dental carries. One debated concern is that hydrofluorosilicic acid, used to fluoridate water, contains arsenic and poses a health risk. This study was undertaken to determine if fluoridation contributes to arsenic in drinking water, to estimate the amount of additional arsenic associated with fluoridation, and compare this to the National Sanitation Foundation/American National Standards Institute (NSF/ANSI) standard and estimates from other researchers. Using surveillance data from Ontario drinking water systems, mixed effects linear regression was performed to examine the effect of fluoridation status on the difference in arsenic concentration between raw water and treated water samples. On average, drinking water treatment was found to reduce arsenic levels in water in both fluoridated and non-fluoridated systems by 0.2 μg/L. However, fluoridated systems were associated with an additional 0.078 μg/L (95% CI 0.021, 0.136) of arsenic in water when compared to non-fluoridated systems (P = 0.008) while controlling for raw water arsenic concentrations, types of treatment processes, and source water type. Our estimate is consistent with concentrations expected from other research and is less than 10% of the NSF/ANSI standard of 1 μg/L arsenic in water. This study provides further information to inform decision-making regarding community water fluoridation.

  20. Caries prevention through the fluoridation of milk. A review.

    Science.gov (United States)

    Bánóczy, Jolán; Rugg-Gunn, Andrew J

    2007-10-01

    The aim of this review is to give an overview of 50 years experience of milk fluoridation and draw conclusions about the applicability of the method. Fluoridated milk was first investigated in the early 1950s, almost simultaneously in Switzerland, the USA and Japan. Stimulated by the favourable results obtained from these early studies, the establishment of The Borrow Dental Milk Foundation (subsequently The Borrow Foundation) in England gave an excellent opportunity for further research, both clinical and non-clinical, and a productive collaboration with the World Health Organization from the early 1980s onwards. Numerous peer-reviewed publications in international journals showed clearly the bioavailability of fluoride in milk, and increased concentrations of fluoride in saliva, dental plaque, dental enamel and dentine, and urine, after consumption of fluoridated milk. Clinical trials were initiated in the 1980s--some of these can be classed as randomised controlled trials, while most of the clinical studies were community preventive programs. These evaluations showed clearly that the optimal daily intake of fluoride in milk is effective in preventing dental caries. At present, milk fluoridation programs are running continuously in about ten countries of the world. Fluoridation of milk can be recommended as a caries preventive measure where the fluoride concentration in drinking water is suboptimal, caries experience in children is significant, and there is an existing school milk program. The program should aim to provide fluoridated milk for at least 200 days per year and should commence before the children are 4 years of age.

  1. Parabens do not increase fluoride uptake by dental enamel

    Directory of Open Access Journals (Sweden)

    Vanessa Silva Tramontino

    2010-04-01

    Full Text Available Objective: To evaluate whether methylparaben and propylparaben, which present a similar chemical structure, increase fluoride uptake by demineralized dental enamel when present in buffered solutions. Methods: The study comprised an in vitro experiment using blocks of bovine dental enamel with artificial carious lesions. Enamel blocks were exposed to the following treatment (n=12: fluoride solution (200 ppm fluoride - control; solution containing fluoride and 13 mM methylparaben; solution containing fluoride and 13 mM propylparaben in 35% propylene glycol; solution containing fluoride in 35% propylene glycol. All solutions were buffered (0.01 M cacodilate and the pH was adjusted to 6.27. The blocks were exposed to the treatment solutions in the proportion of 2 ml per mm2 of exposed enamel area and fluoride formed was estimated after removing an enamel layer by acid etching. Fluoride extracted was determined by ion specific electrode and the amount of enamel removed was estimated by phosphorus analysis. ANOVA followed by Tukey’s test were used for statistical analysis, with significance level at 5%. Results: The dental blocks of treatment groups containing both parabens and the control group presented similar fluoride concentration in enamel and no statistical difference was observed among them (p>0.05. The dental blocks of treatment group containing fluoride and propylene glycol showed the lowest value of fluoride present in enamel, which was significantly different from the control and fluoride and methylparaben groups (p<0.05. Conclusion: Methyl and propylparaben in a buffered solution do not enhance fluoride uptake by demineralized dental enamel.

  2. Analysis of differentially expressed genes between fluoride-sensitive and fluoride-endurable individuals in midgut of silkworm, Bombyx mori.

    Science.gov (United States)

    Qian, Heying; Li, Gang; He, Qingling; Zhang, Huaguang; Xu, Anying

    2016-08-15

    Fluoride tolerance is an economically important trait of silkworm. Near-isogenic lines (NILs) of the dominant endurance to fluoride (Def) gene in Bombyx mori has been constructed before. Here, we analyzed the gene expression profiles of midgut of fluoride-sensitive and fluoride-endurable individuals of Def NILs by using high-throughput Illumina sequencing technology and bioinformatics tools, and identified differentially expressed genes between these individuals. A total of 3,612,399 and 3,567,631 clean tags for the libraries of fluoride-endurable and fluoride-sensitive individuals were obtained, which corresponded to 32,933 and 43,976 distinct clean tags, respectively. Analysis of differentially expressed genes indicates that 241 genes are differentially expressed between the two libraries. Among the 241 genes, 30 are up-regulated and 211 are down-regulated in fluoride-endurable individuals. Pathway enrichment analysis demonstrates that genes related to ribosomes, pancreatic secretion, steroid biosynthesis, glutathione metabolism, steroid biosynthesis, and glycerolipid metabolism are down-regulated in fluoride-endurable individuals. qRT-PCR was conducted to confirm the results of the DGE. The present study analyzed differential expression of related genes and tried to find out whether the crucial genes were related to fluoride detoxification which might elucidate fluoride effect and provide a new way in the fluorosis research. PMID:27106117

  3. Fluoride ion encapsulation by Mg2+ ions and phosphates in a fluoride riboswitch.

    Science.gov (United States)

    Ren, Aiming; Rajashankar, Kanagalaghatta R; Patel, Dinshaw J

    2012-06-01

    Significant advances in our understanding of RNA architecture, folding and recognition have emerged from structure-function studies on riboswitches, non-coding RNAs whose sensing domains bind small ligands and whose adjacent expression platforms contain RNA elements involved in the control of gene regulation. We now report on the ligand-bound structure of the Thermotoga petrophila fluoride riboswitch, which adopts a higher-order RNA architecture stabilized by pseudoknot and long-range reversed Watson-Crick and Hoogsteen A•U pair formation. The bound fluoride ion is encapsulated within the junctional architecture, anchored in place through direct coordination to three Mg(2+) ions, which in turn are octahedrally coordinated to water molecules and five inwardly pointing backbone phosphates. Our structure of the fluoride riboswitch in the bound state shows how RNA can form a binding pocket selective for fluoride, while discriminating against larger halide ions. The T. petrophila fluoride riboswitch probably functions in gene regulation through a transcription termination mechanism. PMID:22678284

  4. Method for decontamination of nickel-fluoride-coated nickel containing actinide-metal fluorides

    Science.gov (United States)

    Windt, Norman F.; Williams, Joe L.

    1983-01-01

    The invention is a process for decontaminating particulate nickel contaminated with actinide-metal fluorides. In one aspect, the invention comprises contacting nickel-fluoride-coated nickel with gaseous ammonia at a temperature effecting nickel-catalyzed dissociation thereof and effecting hydrogen-reduction of the nickel fluoride. The resulting nickel is heated to form a melt and a slag and to effect transfer of actinide metals from the melt into the slag. The melt and slag are then separated. In another aspect, nickel containing nickel oxide and actinide metals is contacted with ammonia at a temperature effecting nickel-catalyzed dissociation to effect conversion of the nickel oxide to the metal. The resulting nickel is then melted and separated as described. In another aspect nickel-fluoride-coated nickel containing actinide-metal fluorides is contacted with both steam and ammonia. The resulting nickel then is melted and separated as described. The invention is characterized by higher nickel recovery, efficient use of ammonia, a substantial decrease in slag formation and fuming, and a valuable increase in the service life of the furnace liners used for melting.

  5. The Effect of Calcium Pre-Rinse on Salivary Fluoride After 900 ppm Fluoride Mouthwash: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Nahid Ramazani

    2013-01-01

    Full Text Available Objective: Calcium fluoride deposit during fluoride application. Uptake and retention of fluoride by saliva depends generally on the concentration of calcium. In this study, the ef-fect of calcium pre-rinse on salivary fluoride concentration after a 900 ppm fluoride mouthwash was investigated.Materials and Methods: This cross-over double-blind randomized clinical trial was con-ducted in a girls' dormitory in Zahedan University of Medical Sciences, southeast Iran. In this study, 42 female dental students were chosen using simple randomization. During the first phase, 21 subjects (group A used fluoride rinse (F regimen and the remaining (group B used calcium pre-rinse followed immediately by fluoride rinse (Ca + F regi-men. In the second phase, participants rinsed using the mouthwashes not previously used. Prior to each phase prophylaxis was performed and no fluoridated product was used dur-ing a two-week interval between the phases. Salivary samples were taken immediately be-fore (baseline, 1 and 12 hours after rinsing. The salivary fluoride concentration was de-termined using fluoride sensitive electrode. Repeated measures ANOVA was used for sta-tistical analysis and the significance level was set at P<0.05.Results: There was significant difference between fluoride concentrations at different time points (P< 0.001. Significant differences were observed when the different time points of two regimens were examined. In contrast to this, the baseline before using F regimen and the baseline before using Ca + F regimen did not show any significance (P= 0.070.Conclusion: Pre-rinsing with calcium before fluoride is recommended because of signifi-cant increases in salivary fluoride concentration.

  6. Fluoridation and tooth wear in Irish adults.

    LENUS (Irish Health Repository)

    Burke, F M

    2010-10-01

    The aim of this study was to determine the prevalence of tooth wear in adults in Ireland and its relationship with water fluoridation. The National Survey of Adult Oral Health was conducted in 2000\\/2001. Tooth wear was determined using a partial mouth examination assessing the upper and lower anterior teeth. A total of 2456 subjects were examined. In this survey, increasing levels and severity of tooth wear were associated with ageing. Men were more affected by tooth wear and were more likely to be affected by severe tooth wear than women. It was found that age, and gender were significant predictors of tooth wear (P < 0.01). Overall, there was no significant relationship between fluoridation and tooth wear in this study.

  7. Revisiting the thermochemistry of chlorine fluorides

    CERN Document Server

    Sánchez, H R

    2016-01-01

    In this work, accurate calculations of standard enthalpies of formation of chlorine fluorides (ClF$_n$, n=1--7; Cl$_2$F and Cl$_3$F$_2$) were performed through the isodesmic reactions scheme. It is argued that, for many chlorine fluorides, the gold standard method of quantum chemistry (CCSD(T)) is not capable to predict enthalpy values nearing chemical accuracy if atomization scheme is used. This is underpinned by a thorough analysis of total atomization energy results and the inspection of multireference features of these compounds. Other thermodynamic quantities were also calculated at different temperatures. In order to complement the energetic description, elimination curves were studied through density functional theory as a computationally affordable alternative to highly correlated wave function-based methods.

  8. Fluoride complexation of element 104, rutherfordium.

    Science.gov (United States)

    Haba, Hiromitsu; Tsukada, Kazuaki; Asai, Masato; Toyoshima, Atsushi; Akiyama, Kazuhiko; Nishinaka, Ichiro; Hirata, Masaru; Yaita, Tsuyoshi; Ichikawa, Shin-Ichi; Nagame, Yuichiro; Yasuda, Ken-Ichiro; Miyamoto, Yutaka; Kaneko, Tetsuya; Goto, Shin-Ichi; Ono, Sawako; Hirai, Toshiyuki; Kudo, Hisaaki; Shigekawa, Mitsuru; Shinohara, Atsushi; Oura, Yasuji; Nakahara, Hiromichi; Sueki, Keisuke; Kikunaga, Hidetoshi; Kinoshita, Norikazu; Tsuruga, Naoya; Yokoyama, Akihiko; Sakama, Minoru; Enomoto, Shuich; Schädel, Matthias; Brüchle, Willy; Kratz, Jens V

    2004-04-28

    Fluoride complexation of element 104, rutherfordium (Rf), produced in the 248Cm(18O,5n)261Rf reaction has been studied by anion-exchange chromatography on an atom-at-a-time scale. The anion-exchange chromatographic behavior of Rf was investigated in 1.9-13.9 M hydrofluoric acid together with those of the group-4 elements Zr and Hf produced in the 18O-induced reactions on Ge and Gd targets, respectively. It was found that the adsorption behavior of Rf on anion-exchange resin is quite different from those of Zr and Hf, suggesting the influence of relativistic effects on the fluoride complexation of Rf.

  9. Narrow spectral width laser diode for metastable argon atoms pumping

    Science.gov (United States)

    Gao, Jun; Li, Bin; Wang, Xinbing; Zuo, Duluo

    2016-03-01

    Diode laser pump source with narrow emitting spectrum for optically pumped metastable rare gas laser (OPRGL) of argon was achieved by employing a complex external cavity coupled with volume Bragg grating (VBG). A commercially available c-mount laser diode with rated power of 6 W was used and studied in both the free running mode and VBG external cavity. The maximum output power of 3.9 W with FWHM less than 25 pm and peak wavelength locked around 811.53 nm was obtained from the VBG external cavity laser diode. Precise control of VBG temperature enabled fine tuning of the emission wavelength over a range of 450 pm. Future researches on OPRGL of argon will benefit from it.

  10. Evaporation and condensation at a liquid surface. I. Argon

    Science.gov (United States)

    Yasuoka, Kenji; Matsumoto, Mitsuhiro; Kataoka, Yosuke

    1994-11-01

    Molecular dynamics computer simulations were carried out to investigate the dynamics of evaporation and condensation for argon at the temperature of 80 and 100 K. From the decrease of the survival probability of vapor molecules, the ratio of self reflection to collision is estimated to be 12%-15%, only weakly dependent on the temperature. This suggests that argon vapor molecules are in the condition of almost complete capture, and the condensation is considered to be a barrierless process. The total ratio of reflection which is evaluated with the flux correlation of condensation and evaporation is 20% at both temperature. The difference between these two ratios of reflection is ascribed to a phenomenon that vapor molecules colliding with the surface drive out other liquid molecules. This molecule exchange at the surface is as important as the self-reflection, and the conventional picture of condensation as a unimolecular chemical reaction is not appropriate.

  11. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.;

    1981-01-01

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore unequivo......The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...... unequivocally associated with electronic processes generated by the bombarding particle. In the present energy region, it is found that Y scales approximately as the electronic stopping power squared, depends on the charge state of the incoming helium ions, and perhaps more important, is independent...

  12. Demonstration of a Lightguide Detector for Liquid Argon TPCs

    CERN Document Server

    Bugel, L; Ignarra, C; Jones, B J P; Katori, T; Smidt, T; Tanaka, H -K

    2011-01-01

    We report demonstration of light detection in liquid argon using an acrylic lightguide detector system. This opens the opportunity for development of an inexpensive, large-area light collection system for large liquid argon time projection chambers. The guides are constructed of acrylic, with TPB embedded in a surface coating with a matching index of refraction. We study the response to early scintillation light produced by a 5.3 MeV alpha. We measure coating responses from 7 to 8 PE on average, compared to an ideal expectation of 10 PE on average. We estimate the attenuation length of light along the lightguide bar to be greater than 0.5 m. The coating response and the attenuation length can be improved; we show, however, that these results are already sufficient for triggering in a large detector.

  13. Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator

    International Nuclear Information System (INIS)

    Background. Distal migration is one of the common complications after insertion of a covered metallic stent. Stent repositioning or removal is not always possible in every patient. Therefore, trimming using an argon plasma coagulator (APC) may be a good alternative method to solve this problem. Methods. Metallic stent trimming by APC was performed in 2 patients with biliary Wallstent migration and in another patient with esophageal Ultraflex stent migration. The power setting was 60-100 watts with an argon flow of 0.8 l/min. Observations. The procedure was successfully performed and all distal parts of the stents were removed. No significant collateral damage to the nearby mucosa was observed. Conclusions. In a patient with a distally migrated metallic stent, trimming of the stent is possible by means of an APC. This new method may be applicable to other sites of metallic stent migration

  14. Readiness of the ATLAS Liquid Argon Calorimeter for LHC Collisions

    CERN Document Server

    Aad, G; Abdallah, J; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abramowicz, H; Abreu, H; Acharya, B S; Adams, D L; Addy, T N; Adelman, J; Adorisio, C; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahmed, H; Ahsan, M; Aielli, G; Akdogan, T; Åkesson, T P A; Akimoto, G; Akimov, A V; Aktas, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alviggi, M G; Amako, K; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Andeen, T; Anders, C F; Anderson, K J; Andreazza, A; Andrei, V; Anduaga, X S; Angerami, A; Anghinolfi, F; Anjos, N; Antonaki, A; Antonelli, M; Antonelli, S; Antunovic, B; Anulli, F; Aoun, S; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Archambault, J P; Arfaoui, S; Arguin, J-F; Argyropoulos, T; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnault, C; Artamonov, A; Arutinov, D; Asai, M; Asai, S; Asfandiyarov, R; Ask, S; Åsman, B; Asner, D; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Atoian, G; Auerbach, B; Auge, E; Augsten, K; Aurousseau, M; Austin, N; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Baccaglioni, G; Bacci, C; Bach, A; Bachacou, H; Bachas, K; Backes, M; Badescu, E; Bagnaia, P; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baltasar Dos Santos Pedrosa, F; Banas, E; Banerjee, P; Banerjee, S; Banfi, D; Bangert, A; Bansal, V; Baranov, S P; Baranov, S; Barashkou, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baron, S; Baroncelli, A; Barr, A J; Barreiro, F; BarreiroGuimarães da Costa, J; Barrillon, P; Barros, N; Bartoldus, R; Bartsch, D; Bastos, J; Bates, R L; Bathe, S; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Bazalova, M; Beare, B; Beau, T; Beauchemin, P H; Beccherle, R; Becerici, N; Bechtle, P; Beck, G A; Beck, H P; Beckingham, M; Becks, K H; Bedajanek, I; Beddall, A J; Beddall, A; Bednár, P; Bednyakov, V A; Bee, C; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Belotskiy, K; Beltramello, O; Ben Ami, S; Benary, O; Benchekroun, D; Bendel, M; Benedict, B H; Benekos, N; Benhammou, Y; Benincasa, G P; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Beretta, M; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernardet, K; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertin, A; Besson, N; Bethke, S; Bianchi, R M; Bianco, M; Biebel, O; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J-B; Blanchot, G; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bocci, A; Boehler, M; Boek, J; Boelaert, N; Böser, S; Bogaerts, J A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Boldyrev, A; Bondarenko, V G; Bondioli, M; Boonekamp, M; Booth, J R A; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borroni, S; Bos, K; Boscherini, D; Bosman, M; Bosteels, M; Boterenbrood, H; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boulahouache, C; Bourdarios, C; Boyd, J; Boyko, I R; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Breton, D; Brett, N D; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Brooijmans, G; Brooks, W K; Brown, G; Brubaker, E; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Bucci, F; Buchanan, J; Buchholz, P; Buckley, A G; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Byatt, T; Caballero, J; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Camarri, P; Cambiaghi, M; Cameron, D; Campabadal-Segura, F; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans-Garrido, M D M; Caprini, I; Caprini, M; Capua, M; Caputo, R; Caracinha, D; Caramarcu, C; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carrillo Montoya, G D; Carron Montero, S; Carter, A A; Carter, J R; Carvalho, J; Casadei, D; Casado, M P; Cascella, M; Caso, C; Castaneda Hernadez, A M; Castaneda-Miranda, E; Castillo Gimenez, V; Castro, N; Cataldi, G; Catinaccio, A; Catmore, J R; Cattai, A; Cattani, G; Caughron, S; Cauz, D; Cavalleri, P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Ceradini, F; Cerqueira, A S; Cerri, A; Cerrito, L; Cerutti, F; Cetin, S A; Cevenini, F; Chafaq, A; Chakraborty, D; Chan, K; Chapman, J D; Chapman, J W; Chareyre, E; Charlton, D G; Chavda, V; Cheatham, S; Chekanov, S; Chekulaev, S V; Chelkov, G A; Chen, H; Chen, S; Chen, T; Chen, X; Cheng, S; Cheplakov, A; Chepurnov, V F; Cherkaoui El Moursli, R; Tcherniatine, V; Chesneanu, D; Cheu, E; Cheung, S L; Chevalier, L; Chevallier, F; Chiarella, V; Chiefari, G; Chikovani, L; Childers, J T; Chilingarov, A; Chiodini, G; Chizhov, M; Choudalakis, G; Chouridou, S; Chren, D; Christidi, I A; Christov, A; Chromek-Burckhart, D; Chu, M L; Chudoba, J; Ciapetti, G; Ciftci, A K; Ciftci, R; Cinca, D; Cindro, V; Ciobotaru, M D; Ciocca, C; Ciocio, A; Cirilli, M; Citterio, M; Clark, A; Cleland, W; Clemens, J C; Clement, B; Clement, C; Clements, D; Coadou, Y; Cobal, M; Coccaro, A; Cochran, J; Coelli, S; Coggeshall, J; Cogneras, E; Cojocaru, C D; Colas, J; Cole, B; Colijn, A P; Collard, C; Collins, N J; Collins-Tooth, C; Collot, J; Colon, G; Coluccia, R; Conde Muiño, P; Coniavitis, E; Consonni, M; Constantinescu, S; Conta, C; Conventi, F; Cook, J; Cooke, M; Cooper, B D; Cooper-Sarkar, A M; Cooper-Smith, N J; Copic, K; Cornelissen, T; Corradi, M; Corriveau, F; Corso-Radu, A; Cortes-Gonzalez, A; Cortiana, G; Costa, G; Costa, M J; Costanzo, D; Costin, T; Côté, D; Coura Torres, R; Courneyea, L; Cowan, G; Cowden, C; Cox, B E; Cranmer, K; Cranshaw, J; Cristinziani, M; Crosetti, G; Crupi, R; Crépé-Renaudin, S; Cuenca Almenar, C; Cuhadar Donszelmann, T; Curatolo, M; Curtis, C J; Cwetanski, P; Czyczula, Z; D'Auria, S; D'Onofrio, M; D'Orazio, A; Da Silva, P V M; Da Via, C; Dabrowski, W; Dai, T; Dallapiccola, C; Dallison, S J; Daly, C H; Dam, M; Danielsson, H O; Dannheim, D; Dao, V; Darbo, G; Darlea, G L; Davey, W; Davidek, T; Davidson, N; Davidson, R; Davison, A R; Dawson, I; Dawson, J W; Daya, R K; De, K; de Asmundis, R; De Castro, S; De Castro Faria Salgado, P E; De Cecco, S; de Graat, J; De Groot, N; de Jong, P; De La Cruz Burelo, E; De La Taille, C; De Mora, L; De Oliveira Branco, M; De Pedis, D; De Salvo, A; De Sanctis, U; De Santo, A; De Vivie De Regie, J B; De Zorzi, G; Dean, S; Deberg, H; Dedes, G; Dedovich, D V; Defay, P O; Degenhardt, J; Dehchar, M; Del Papa, C; Del Peso, J; Del Prete, T; Dell'Acqua, A; Dell'Asta, L; Della Pietra, M; della Volpe, D; Delmastro, M; Delruelle, N; Delsart, P A; Deluca, C; Demers, S; Demichev, M; Demirkoz, B; Deng, J; Deng, W; Denisov, S P; Dennis, C; Derkaoui, J E; Derue, F; Dervan, P; Desch, K; Deviveiros, P O; Dewhurst, A; DeWilde, B; Dhaliwal, S; Dhullipudi, R; Di Ciaccio, A; Di Ciaccio, L; Di Domenico, A; Di Girolamo, A; Di Girolamo, B; Di Luise, S; Di Mattia, A; Di Nardo, R; Di Simone, A; Di Sipio, R; Diaz, M A; Diblen, F; Diehl, E B; Dietrich, J; Diglio, S; Dindar Yagci, K; Dingfelder, D J; Dionisi, C; Dita, P; Dita, S; Dittus, F; Djama, F; Djilkibaev, R; Djobava, T; do Vale, M A B; Do Valle Wemans, A; Dobbs, M; Dobos, D; Dobson, E; Dobson, M; Dodd, J; Dogan, O B; Doherty, T; Doi, Y; Dolejsi, J; Dolenc, I; Dolezal, Z; Dolgoshein, B A; Dohmae, T; Donega, M; Donini, J; Dopke, J; Doria, A; Dos Anjos, A; Dotti, A; Dova, M T; Doxiadis, A; Doyle, A T; Drasal, Z; Driouichi, C; Dris, M; Dubbert, J; Duchovni, E; Duckeck, G; Dudarev, A; Dudziak, F; Dührssen , M; Duflot, L; Dufour, M-A; Dunford, M; Duperrin, A; Duran-Yildiz, H; Dushkin, A; Duxfield, R; Dwuznik, M; Düren, M; Ebenstein, W L; Ebke, J; Eckert, S; Eckweiler, S; Edmonds, K; Edwards, C A; Eerola, P; Egorov, K; Ehrenfeld, W; Ehrich, T; Eifert, T; Eigen, G; Einsweiler, K; Eisenhandler, E; Ekelof, T; El Kacimi, M; Ellert, M; Elles, S; Ellinghaus, F; Ellis, K; Ellis, N; Elmsheuser, J; Elsing, M; Ely, R; Emeliyanov, D; Engelmann, R; Engl, A; Epp, B; Eppig, A; Epshteyn, V S; Ereditato, A; Eriksson, D; Ermoline, I; Ernst, J; Ernst, M; Ernwein, J; Errede, D; Errede, S; Ertel, E; Escalier, M; Escobar, C; Espinal Curull, X; Esposito, B; Etienne, F; Etienvre, A I; Etzion, E; Evans, H; Fabbri, L; Fabre, C; Faccioli, P; Facius, K; Fakhrutdinov, R M; Falciano, S; Falou, A C; Fang, Y; Fanti, M; Farbin, A; Farilla, A; Farley, J; Farooque, T; Farrington, S M; Farthouat, P; Fassi, F; Fassnacht, P; Fassouliotis, D; Fatholahzadeh, B; Fayard, L; Fayette, F; Febbraro, R; Federic, P; Fedin, O L; Fedorko, I; Fedorko, W; Feligioni, L; Felzmann, C U; Feng, C; Feng, E J; Fenyuk, A B; Ferencei, J; Ferland, J; Fernandes, B; Fernando, W; Ferrag, S; Ferrando, J; Ferrari, A; Ferrari, P; Ferrari, R; Ferrer, A; Ferrer, M L; Ferrere, D; Ferretti, C; Fiascaris, M; Fiedler, F; Filipcic, A; Filippas, A; Filthaut, F; Fincke-Keeler, M; Fiolhais, M C N; Fiorini, L; Firan, A; Fischer, G; Fisher, M J; Flechl, M; Fleck, I; Fleckner, J; Fleischmann, P; Fleischmann, S; Flick, T; Flores-Castillo, L R; Flowerdew, M J; Föhlisch, F; Fokitis, M; Fonseca Martin, T; Forbush, D A; Formica, A; Forti, A; Fortin, D; Foster, J M; Fournier, D; Foussat, A; Fowler, A J; Fowler, K; Fox, H; Francavilla, P; Franchino, S; Francis, D; Franklin, M; Franz, S; Fraternali, M; Fratina, S; Freestone, J; French, S T; Froeschl, R; Froidevaux, D; Frost, J A; Fukunaga, C; Fullana Torregrosa, E; Fuster, J; Gabaldon, C; Gabizon, O; Gadfort, T; Gadomski, S; Gagliardi, G; Gagnon, P; Galea, C; Gallas, E J; Gallas, M V; Gallop, B J; Gallus, P; Galyaev, E; Gan, K K; Gao, Y S; Gaponenko, A; Garcia-Sciveres, M; Garcí­a, C; Garcí­a Navarro, J E; Gardner, R W; Garelli, N; Garitaonandia, H; Garonne, V; Gatti, C; Gaudio, G; Gaumer, O; Gauzzi, P; Gavrilenko, I L; Gay, C; Gaycken, G; Gayde, J-C; Gazis, E N; Ge, P; Gee, C N P; Geich-Gimbel, Ch; Gellerstedt, K; Gemme, C; Genest, M H; Gentile, S; Georgatos, F; George, S; Gerlach, P; Gershon, A; Geweniger, C; Ghazlane, H; Ghez, P; Ghodbane, N; Giacobbe, B; Giagu, S; Giakoumopoulou, V; Giangiobbe, V; Gianotti, F; Gibbard, B; Gibson, A; Gibson, S M; Gilbert, L M; Gilchriese, M; Gilewsky, V; Gillberg, D; Gillman, A R; Gingrich, D M; Ginzburg, J; Giokaris, N; Giordani, M P; Giordano, R; Giovannini, P; Giraud, P F; Girtler, P; Giugni, D; Giusti, P; Gjelsten, B K; Gladilin, L K; Glasman, C; Glazov, A; Glitza, K W; Glonti, G L; Godfrey, J; Godlewski, J; Goebel, M; Göpfert, T; Goeringer, C; Gössling, C; Göttfert, T; Goggi, V; Goldfarb, S; Goldin, D; Golling, T; Gollub, N P; Gomes, A; Gomez Fajardo, L S; Gonçalo, R; Gonella, L; Gong, C; González de la Hoz, S; Gonzalez Silva, M L; Gonzalez-Sevilla, S; Goodson, J J; Goossens, L; Gorbounov, P A; Gordon, H A; Gorelov, I; Gorfine, G; Gorini, B; Gorini, E; Gorisek, A; Gornicki, E; Goryachev, S V; Goryachev, V N; Gosdzik, B; Gosselink, M; Gostkin, M I; Gough Eschrich, I; Gouighri, M; Goujdami, D; Goulette, M P; Goussiou, A G; Goy, C; Grabowska-Bold, I; Grafström, P; Grahn, K-J; Granado Cardoso, L; Grancagnolo, F; Grancagnolo, S; Grassi, V; Gratchev, V; Grau, N; Gray, H M; Gray, J A; Graziani, E; Green, B; Greenshaw, T; Greenwood, Z D; Gregor, I M; Grenier, P; Griesmayer, E; Griffiths, J; Grigalashvili, N; Grillo, A A; Grimm, K; Grinstein, S; Grishkevich, Y V; Groer, L S; Grognuz, J; Groh, M; Groll, M; Gross, E; Grosse-Knetter, J; Groth-Jensen, J; Grybel, K; Guarino, V J; Guicheney, C; Guida, A; Guillemin, T; Guler, H; Gunther, J; Guo, B; Gupta, A; Gusakov, Y; Gutierrez, A; Gutierrez, P; Guttman, N; Gutzwiller, O; Guyot, C; Gwenlan, C; Gwilliam, C B; Haas, A; Haas, S; Haber, C; Hackenburg, R; Hadavand, H K; Hadley, D R; Haefner, P; Härtel, R; Hajduk, Z; Hakobyan, H; Haller, J; Hamacher, K; Hamilton, A; Hamilton, S; Han, H; Han, L; Hanagaki, K; Hance, M; Handel, C; Hanke, P; Hansen, J R; Hansen, J B; Hansen, J D; Hansen, P H; Hansl-Kozanecka, T; Hansson, P; Hara, K; Hare, G A; Harenberg, T; Harrington, R D; Harris, O B; Harris, O M; Harrison, K; Hartert, J; Hartjes, F; Haruyama, T; Harvey, A; Hasegawa, S; Hasegawa, Y; Hashemi, K; Hassani, S; Hatch, M; Haug, F; Haug, S; Hauschild, M; Hauser, R; Havranek, M; Hawkes, C M; Hawkings, R J; Hawkins, D; Hayakawa, T; Hayward, H S; Haywood, S J; He, M; Head, S J; Hedberg, V; Heelan, L; Heim, S; Heinemann, B; Heisterkamp, S; Helary, L; Heller, M; Hellman, S; Helsens, C; Hemperek, T; Henderson, R C W; Henke, M; Henrichs, A; Henriques-Correia, A M; Henrot-Versille, S; Hensel, C; Henß, T; Hershenhorn, A D; Herten, G; Hertenberger, R; Hervas, L; Hessey, N P; Hidvegi, A; Higón-Rodriguez, E; Hill, D; Hill, J C; Hiller, K H; Hillier, S J; Hinchliffe, I; Hirose, M; Hirsch, F; Hobbs, J; Hod, N; Hodgkinson, M C; Hodgson, P; Hoecker, A; Hoeferkamp, M R; Hoffman, J; Hoffmann, D; Hohlfeld, M; Holmgren, S O; Holy, T; Holzbauer, J L; Homma, Y; Homola, P; Horazdovsky, T; Hori, T; Horn, C; Horner, S; Horvat, S; Hostachy, J-Y; Hou, S; Houlden, M A; Hoummada, A; Howe, T; Hrivnac, J; Hryn'ova, T; Hsu, P J; Hsu, S-C; Huang, G S; Hubacek, Z; Hubaut, F; Huegging, F; Hughes, E W; Hughes, G; Hughes-Jones, R E; Hurst, P; Hurwitz, M; Husemann, U; Huseynov, N; Huston, J; Huth, J; Iacobucci, G; Iakovidis, G; Ibragimov, I; Iconomidou-Fayard, L; Idarraga, J; Iengo, P; Igonkina, O; Ikegami, Y; Ikeno, M; Ilchenko, Y; Iliadis, D; Ilyushenka, Y; Imori, M; Ince, T; Ioannou, P; Iodice, M; Irles-Quiles, A; Ishikawa, A; Ishino, M; Ishmukhametov, R; Isobe, T; Issakov, V; Issever, C; Istin, S; Itoh, Y; Ivashin, A V; Iwanski, W; Iwasaki, H; Izen, J M; Izzo, V; Jackson, J N; Jackson, P; Jaekel, M; Jahoda, M; Jain, V; Jakobs, K; Jakobsen, S; Jakubek, J; Jana, D; Jansen, E; Jantsch, A; Janus, M; Jared, R C; Jarlskog, G; Jarron, P; Jeanty, L; Jelen, K; Jen-La Plante, I; Jenni, P; Jez, P; Jézéquel, S; Ji, W; Jia, J; Jiang, Y; Jimenez Belenguer, M; Jin, G; Jin, S; Jinnouchi, O; Joffe, D; Johansen, M; Johansson, K E; Johansson, P; Johnert, S; Johns, K A; Jon-And, K; Jones, G; Jones, R W L; Jones, T W; Jones, T J; Jonsson, O; Joos, D; Joram, C; Jorge, P M; Juranek, V; Jussel, P; Kabachenko, V V; Kabana, S; Kaci, M; Kaczmarska, A; Kado, M; Kagan, H; Kagan, M; Kaiser, S; Kajomovitz, E; Kalinovskaya, L V; Kalinowski, A; Kama, S; Kanaya, N; Kaneda, M; Kantserov, V A; Kanzaki, J; Kaplan, B; Kapliy, A; Kaplon, J; Karagounis, M; Karagoz Unel, M; Kartvelishvili, V; Karyukhin, A N; Kashif, L; Kasmi, A; Kass, R D; Kastanas, A; Kastoryano, M; Kataoka, M; Kataoka, Y; Katsoufis, E; Katzy, J; Kaushik, V; Kawagoe, K; Kawamoto, T; Kawamura, G; Kayl, M S; Kayumov, F; Kazanin, V A; Kazarinov, M Y; Kazi, S I; Keates, J R; Keeler, R; Keener, P T; Kehoe, R; Keil, M; Kekelidze, G D; Kelly, M; Kennedy, J; Kenyon, M; Kepka, O; Kerschen, N; Kersevan, B P; Kersten, S; Kessoku, K; Khakzad, M; Khalil-zada, F; Khandanyan, H; Khanov, A; Kharchenko, D; Khodinov, A; Kholodenko, A G; Khomich, A; Khoriauli, G; Khovanskiy, N; Khovanskiy, V; Khramov, E; Khubua, J; Kilvington, G; Kim, H; Kim, M S; Kim, P C; Kim, S H; Kind, O; Kind, P; King, B T; Kirk, J; Kirsch, G P; Kirsch, L E; Kiryunin, A E; Kisielewska, D; Kittelmann, T; Kiyamura, H; Kladiva, E; Klein, M; Klein, U; Kleinknecht, K; Klemetti, M; Klier, A; Klimentov, A; Klingenberg, R; Klinkby, E B; Klioutchnikova, T; Klok, P F; Klous, S; Kluge, E-E; Kluge, T; Kluit, P; Klute, M; Kluth, S; Knecht, N S; Kneringer, E; Ko, B R; Kobayashi, T; Kobel, M; Koblitz, B; Kocian, M; Kocnar, A; Kodys, P; Köneke, K; König, A C; Köpke, L; Koetsveld, F; Koevesarki, P; Koffas, T; Koffeman, E; Kohn, F; Kohout, Z; Kohriki, T; Kokott, T; Kolanoski, H; Kolesnikov, V; Koletsou, I; Koll, J; Kollar, D; Kolos, S; Kolya, S D; Komar, A A; Komaragiri, J R; Kondo, T; Kono, T; Kononov, A I; Konoplich, R; Konovalov, S P; Konstantinidis, N; Koperny, S; Korcyl, K; Kordas, K; Koreshev, V; Korn, A; Korolkov, I; Korolkova, E V; Korotkov, V A; Kortner, O; Kostka, P; Kostyukhin, V V; Kotamäki, M J; Kotov, S; Kotov, V M; Kotov, K Y; Koupilova, Z; Kourkoumelis, C; Koutsman, A; Kowalewski, R; Kowalski, H; Kowalski, T Z; Kozanecki, W; Kozhin, A S; Kral, V; Kramarenko, V A; Kramberger, G; Krasny, M W; Krasznahorkay, A; Kreisel, A; Krejci, F; Krepouri, A; Kretzschmar, J; Krieger, P; Krobath, G; Kroeninger, K; Kroha, H; Kroll, J; Kroseberg, J; Krstic, J; Kruchonak, U; Krüger, H; Krumshteyn, Z V; Kubota, T; Kuehn, S; Kugel, A; Kuhl, T; Kuhn, D; Kukhtin, V; Kulchitsky, Y; Kuleshov, S; Kummer, C; Kuna, M; Kupco, A; Kurashige, H; Kurata, M; Kurchaninov, L L; Kurochkin, Y A; Kus, V; Kuykendall, W; Kuznetsova, E; Kvasnicka, O; Kwee, R; La Rosa, M; La Rotonda, L; Labarga, L; Labbe, J; Lacasta, C; Lacava, F; Lacker, H; Lacour, D; Lacuesta, V R; Ladygin, E; Lafaye, R; Laforge, B; Lagouri, T; Lai, S; Lamanna, M; Lampen, C L; Lampl, W; Lancon, E; Landgraf, U; Landon, M P J; Lane, J L; Lankford, A J; Lanni, F; Lantzsch, K; Lanza, A; Laplace, S; Lapoire, C; Laporte, J F; Lari, T; Larionov, A V; Larner, A; Lasseur, C; Lassnig, M; Laurelli, P; Lavrijsen, W; Laycock, P; Lazarev, A B; Lazzaro, A; Le Dortz, O; Le Guirriec, E; Le Maner, C; Le Menedeu, E; Le Vine, M; Leahu, M; Lebedev, A; Lebel, C; LeCompte, T; Ledroit-Guillon, F; Lee, H; Lee, J S H; Lee, S C; Lefebvre, M; Legendre, M; LeGeyt, B C; Legger, F; Leggett, C; Lehmacher, M; Lehmann Miotto, G; Lei, X; Leitner, R; Lelas, D; Lellouch, D; Lellouch, J; Leltchouk, M; Lendermann, V; Leney, K J C; Lenz, T; Lenzen, G; Lenzi, B; Leonhardt, K; Leroy, C; Lessard, J-R; Lester, C G; Leung Fook Cheong, A; Levêque, J; Levin, D; Levinson, L J; Levitski, M S; Levonian, S; Lewandowska, M; Leyton, M; Li, H; Li, J; Li, S; Li, X; Liang, Z; Liang, Z; Liberti, B; Lichard, P; Lichtnecker, M; Lie, K; Liebig, W; Liko, D; Lilley, J N; Lim, H; Limosani, A; Limper, M; Lin, S C; Lindsay, S W; Linhart, V; Linnemann, J T; Liolios, A; Lipeles, E; Lipinsky, L; Lipniacka, A; Liss, T M; Lissauer, D; Litke, A M; Liu, C; Liu, D; Liu, H; Liu, J B; Liu, M; Liu, S; Liu, T; Liu, Y; Livan, M; Lleres, A; Lloyd, S L; Lobodzinska, E; Loch, P; Lockman, W S; Lockwitz, S; Loddenkoetter, T; Loebinger, F K; Loginov, A; Loh, C W; Lohse, T; Lohwasser, K; Lokajicek, M; Loken, J; Lopes, L; Lopez Mateos, D; Losada, M; Loscutoff, P; Losty, M J; Lou, X; Lounis, A; Loureiro, K F; Lovas, L; Love, J; Love, P; Lowe, A J; Lu, F; Lu, J; Lubatti, H J; Luci, C; Lucotte, A; Ludwig, A; Ludwig, D; Ludwig, I; Ludwig, J; Luehring, F; Luisa, L; Lumb, D; Luminari, L; Lund, E; Lund-Jensen, B; Lundberg, B; Lundberg, J; Lundquist, J; Lutz, G; Lynn, D; Lys, J; Lytken, E; Ma, H; Ma, L L; Maccarrone, G; Macchiolo, A; Macek, B; Machado Miguens, J; Mackeprang, R; Madaras, R J; Mader, W F; Maenner, R; Maeno, T; Mättig, P; Mättig, S; Magalhaes Martins, P J; Magradze, E; Magrath, C A; Mahalalel, Y; Mahboubi, K; Mahmood, A; Mahout, G; Maiani, C; Maidantchik, C; Maio, A; Majewski, S; Makida, Y; Makouski, M; Makovec, N; Malecki, Pa; Malecki, P; Maleev, V P; Malek, F; Mallik, U; Malon, D; Maltezos, S; Malyshev, V; Malyukov, S; Mambelli, M; Mameghani, R; Mamuzic, J; Manabe, A; Mandelli, L; Mandic, I; Mandrysch, R; Maneira, J; Mangeard, P S; Manjavidze, I D; Manousakis-Katsikakis, A; Mansoulie, B; Mapelli, A; Mapelli, L; March, L; Marchand, J F; Marchese, F; Marcisovsky, M; Marino, C P; Marques, C N; Marroquim, F; Marshall, R; Marshall, Z; Martens, F K; Marti i Garcia, S; Martin, A J; Martin, A J; Martin, B; Martin, B; Martin, F F; Martin, J P; Martin, T A; Martin dit Latour, B; Martinez, M; Martinez Outschoorn, V; Martini, A; Martynenko, V; Martyniuk, A C; Maruyama, T; Marzano, F; Marzin, A; Masetti, L; Mashimo, T; Mashinistov, R; Masik, J; Maslennikov, A L; Massaro, G; Massol, N; Mastroberardino, A; Masubuchi, T; Mathes, M; Matricon, P; Matsumoto, H; Matsunaga, H; Matsushita, T; Mattravers, C; Maxfield, S J; May, E N; Mayne, A; Mazini, R; Mazur, M; Mazzanti, M; Mazzanti, P; Mc Donald, J; Mc Kee, S P; McCarn, A; McCarthy, R L; McCubbin, N A; McFarlane, K W; McGlone, H; Mchedlidze, G; McLaren, R A; McMahon, S J; McMahon, T R; McPherson, R A; Meade, A; Mechnich, J; Mechtel, M; Medinnis, M; Meera-Lebbai, R; Meguro, T M; Mehdiyev, R; Mehlhase, S; Mehta, A; Meier, K; Meirose, B; Melamed-Katz, A; Mellado Garcia, B R; Meng, Z; Menke, S; Meoni, E; Merkl, D; Mermod, P; Merola, L; Meroni, C; Merritt, F S; Messina, A M; Messmer, I; Metcalfe, J; Mete, A S; Meyer, J-P; Meyer, J; Meyer, T C; Meyer, W T; Miao, J; Micu, L; Middleton, R P; Migas, S; Mijovic, L; Mikenberg, G; Mikuz, M; Miller, D W; Mills, W J; Mills, C M; Milov, A; Milstead, D A; Minaenko, A A; Miñano, M; Minashvili, I A; Mincer, A I; Mindur, B; Mineev, M; Mir, L M; Mirabelli, G; Misawa, S; Miscetti, S; Misiejuk, A; Mitrevski, J; Mitsou, V A; Miyagawa, P S; Mjörnmark, J U; Mladenov, D; Moa, T; Mockett, P; Moed, S; Moeller, V; Mönig, K; Möser, N; Mohn, B; Mohr, W; Mohrdieck-Möck, S; Moles-Valls, R; Molina-Perez, J; Moloney, G; Monk, J; Monnier, E; Montesano, S; Monticelli, F; Moore, R W; Mora-Herrera, C; Moraes, A; Morais, A; Morel, J; Morello, G; Moreno, D; Moreno Llácer, M; Morettini, P; Morii, M; Morley, A K; Mornacchi, G; Morozov, S V; Morris, J D; Moser, H G; Mosidze, M; Moss, J; Mount, R; Mountricha, E; Mouraviev, S V; Moyse, E J W; Mudrinic, M; Mueller, F; Mueller, J; Mueller, K; Müller, T A; Muenstermann, D; Muir, A; Murillo Garcia, R; Murray, W J; Mussche, I; Musto, E; Myagkov, A G; Myska, M; Nadal, J; Nagai, K; Nagano, K; Nagasaka, Y; Nairz, A M; Nakamura, K; Nakano, I; Nakatsuka, H; Nanava, G; Napier, A; Nash, M; Nation, N R; Nattermann, T; Naumann, T; Navarro, G; Nderitu, S K; Neal, H A; Nebot, E; Nechaeva, P; Negri, A; Negri, G; Nelson, A; Nelson, T K; Nemecek, S; Nemethy, P; Nepomuceno, A A; Nessi, M; Neubauer, M S; Neusiedl, A; Neves, R N; Nevski, P; Newcomer, F M; Nicholson, C; Nickerson, R B; Nicolaidou, R; Nicolas, L; Nicoletti, G; Niedercorn, F; Nielsen, J; Nikiforov, A; Nikolaev, K; Nikolic-Audit, I; Nikolopoulos, K; Nilsen, H; Nilsson, P; Nisati, A; Nishiyama, T; Nisius, R; Nodulman, L; Nomachi, M; Nomidis, I; Nomoto, H; Nordberg, M; Nordkvist, B; Notz, D; Novakova, J; Nozaki, M; Nozicka, M; Nugent, I M; Nuncio-Quiroz, A-E; Nunes Hanninger, G; Nunnemann, T; Nurse, E; O'Neil, D C; O'Shea, V; Oakham, F G; Oberlack, H; Ochi, A; Oda, S; Odaka, S; Odier, J; Odino, G A; Ogren, H; Oh, S H; Ohm, C C; Ohshima, T; Ohshita, H; Ohsugi, T; Okada, S; Okawa, H; Okumura, Y; Olcese, M; Olchevski, A G; Oliveira, M; Oliveira Damazio, D; Oliver, J; Oliver Garcia, E; Olivito, D; Olszewski, A; Olszowska, J; Omachi, C; Onofre, A; Onyisi, P U E; Oram, C J; Ordonez, G; Oreglia, M J; Oren, Y; Orestano, D; Orlov, I; Oropeza Barrera, C; Orr, R S; Ortega, E O; Osculati, B; Osuna, C; Otec, R; Ottersbach, J P; Ould-Saada, F; Ouraou, A; Ouyang, Q; Owen, M; Owen, S; Ozcan, V E; Ozone, K; Ozturk, N; Pacheco Pages, A; Padhi, S; Padilla Aranda, C; Paganis, E; Pahl, C; Paige, F; Pajchel, K; Pal, A; Palestini, S; Pallin, D; Palma, A; Palmer, J D; Pan, Y B; Panagiotopoulou, E; Panes, B; Panikashvili, N; Panitkin, S; Pantea, D; Panuskova, M; Paolone, V; Papadopoulou, Th D; Park, S J; Park, W; Parker, M A; Parker, S I; Parodi, F; Parsons, J A; Parzefall, U; Pasqualucci, E; Passardi, G; Passeri, A; Pastore, F; Pastore, Fr; Pásztor, G; Pataraia, S; Pater, J R; Patricelli, S; Patwa, A; Pauly, T; Peak, L S; Pecsy, M; Pedraza Morales, M I; Peleganchuk, S V; Peng, H; Penson, A; Penwell, J; Perantoni, M; Perez, K; Perez Codina, E; Pérez García-Estañ, M T; Perez Reale, V; Perini, L; Pernegger, H; Perrino, R; Perrodo, P; Persembe, S; Perus, P; Peshekhonov, V D; Petersen, B A; Petersen, J; Petersen, T C; Petit, E; Petridou, C; Petrolo, E; Petrucci, F; Petschull, D; Petteni, M; Pezoa, R; Pfeifer, B; Phan, A; Phillips, A W; Piacquadio, G; Piccinini, M; Piegaia, R; Pilcher, J E; Pilkington, A D; Pina, J; Pinamonti, M; Pinfold, J L; Ping, J; Pinto, B; Pirotte, O; Pizio, C; Placakyte, R; Plamondon, M; Plano, W G; Pleier, M-A; Poblaguev, A; Poddar, S; Podlyski, F; Poffenberger, P; Poggioli, L; Pohl, M; Polci, F; Polesello, G; Policicchio, A; Polini, A; Poll, J; Polychronakos, V; Pomarede, D M; Pomeroy, D; Pommès, K; Pontecorvo, L; Pope, B G; Popovic, D S; Poppleton, A; Popule, J; Portell Bueso, X; Porter, R; Pospelov, G E; Pospichal, P; Pospisil, S; Potekhin, M; Potrap, I N; Potter, C J; Potter, C T; Potter, K P; Poulard, G; Poveda, J; Prabhu, R; Pralavorio, P; Prasad, S; Pravahan, R; Preda, T; Pretzl, K; Pribyl, L; Price, D; Price, L E; Prichard, P M; Prieur, D; Primavera, M; Prokofiev, K; Prokoshin, F; Protopopescu, S; Proudfoot, J; Prudent, X; Przysiezniak, H; Psoroulas, S; Ptacek, E; Puigdengoles, C; Purdham, J; Purohit, M; Puzo, P; Pylypchenko, Y; Qi, M; Qian, J; Qian, W; Qian, Z; Qin, Z; Qing, D; Quadt, A; Quarrie, D R; Quayle, W B; Quinonez, F; Raas, M; Radeka, V; Radescu, V; Radics, B; Rador, T; Ragusa, F; Rahal, G; Rahimi, A M; Rahm, D; Rajagopalan, S; Rammes, M; Ratoff, P N; Rauscher, F; Rauter, E; Raymond, M; Read, A L; Rebuzzi, D M; Redelbach, A; Redlinger, G; Reece, R; Reeves, K; Reinherz-Aronis, E; Reinsch, A; Reisinger, I; Reljic, D; Rembser, C; Ren, Z L; Renkel, P; Rescia, S; Rescigno, M; Resconi, S; Resende, B; Reznicek, P; Rezvani, R; Richards, A; Richards, R A; Richter, D; Richter, R; Richter-Was, E; Ridel, M; Rieke, S; Rijpstra, M; Rijssenbeek, M; Rimoldi, A; Rinaldi, L; Rios, R R; Riu, I; Rivoltella, G; Rizatdinova, F; Rizvi, E R; Roa-Romero, D A; Robertson, S H; Robichaud-Veronneau, A; Robinson, D; Robinson, M; Robson, A; Rocha de Lima, J G; Roda, C; Rodriguez, D; Rodriguez Garcia, Y; Roe, S; Røhne, O; Rojo, V; Rolli, S; Romaniouk, A; Romanov, V M; Romeo, G; Romero-Maltrana, D; Roos, L; Ros, E; Rosati, S; Rosenbaum, G A; Rosenberg, E I; Rosselet, L; Rossi, L P; Rotaru, M; Rothberg, J; Rottländer, I; Rousseau, D; Royon, C R; Rozanov, A; Rozen, Y; Ruan, X; Ruckert, B; Ruckstuhl, N; Rud, V I; Rudolph, G; Rühr, F; Ruggieri, F; Ruiz-Martinez, A; Rumyantsev, L; Rusakovich, N A; Rutherfoord, J P; Ruwiedel, C; Ruzicka, P; Ryabov, Y F; Ryadovikov, V; Ryan, P; Rybkin, G; Rzaeva, S; Saavedra, A F; Sadrozinski, H F-W; Sadykov, R; Sakamoto, H; Salamanna, G; Salamon, A; Saleem, M; Salihagic, D; Salnikov, A; Salt, J; Salvachua-Ferrando, B M; Salvatore, D; Salvatore, F; Salvucci, A; Salzburger, A; Sampsonidis, D; Samset, B H; Sanchis Lozano, M A; Sandaker, H; Sander, H G; Sanders, M P; Sandhoff, M; Sandstroem, R; Sandvoss, S; Sankey, D P C; Sanny, B; Sansoni, A; Santamarina Rios, C; Santi, L; Santoni, C; Santonico, R; Santos, D; Santos, J; Saraiva, J G; Sarangi, T; Sarkisyan-Grinbaum, E; Sarri, F; Sasaki, O; Sasaki, T; Sasao, N; Satsounkevitch, I; Sauvage, G; Savard, P; Savine, A Y; Savinov, V; Sawyer, L; Saxon, D H; Says, L P; Sbarra, C; Sbrizzi, A; Scannicchio, D A; Schaarschmidt, J; Schacht, P; Schäfer, U; Schaetzel, S; Schaffer, A C; Schaile, D; Schamberger, R D; Schamov, A G; Schegelsky, V A; Scheirich, D; Schernau, M; Scherzer, M I; Schiavi, C; Schieck, J; Schioppa, M; Schlenker, S; Schlereth, J L; Schmid, P; Schmidt, M P; Schmieden, K; Schmitt, C; Schmitz, M; Schott, M; Schouten, D; Schovancova, J; Schram, M; Schreiner, A; Schroeder, C; Schroer, N; Schroers, M; Schuler, G; Schultes, J; Schultz-Coulon, H-C; Schumacher, J; Schumacher, M; Schumm, B A; Schune, Ph; Schwanenberger, C; Schwartzman, A; Schwemling, Ph; Schwienhorst, R; Schwierz, R; Schwindling, J; Scott, W G; Searcy, J; Sedykh, E; Segura, E; Seidel, S C; Seiden, A; Seifert, F; Seixas, J M; Sekhniaidze, G; Seliverstov, D M; Sellden, B; Seman, M; Semprini-Cesari, N; Serfon, C; Serin, L; Seuster, R; Severini, H; Sevior, M E; Sfyrla, A; Shamim, M; Shan, L Y; Shank, J T; Shao, Q T; Shapiro, M; Shatalov, P B; Shaver, L; Shaw, C; Shaw, K; Sherman, D; Sherwood, P; Shibata, A; Shimojima, M; Shin, T; Shmeleva, A; Shochet, M J; Shupe, M A; Sicho, P; Sidoti, A; Siebel, A; Siegert, F; Siegrist, J; Sijacki, Dj; Silbert, O; Silva, J; Silver, Y; Silverstein, D; Silverstein, S B; Simak, V; Simic, Lj; Simion, S; Simmons, B; Simonyan, M; Sinervo, P; Sinev, N B; Sipica, V; Siragusa, G; Sisakyan, A N; Sivoklokov, S Yu; Sjoelin, J; Sjursen, T B; Skubic, P; Skvorodnev, N; Slater, M; Slavicek, T; Sliwa, K; Sloper, J; Sluka, T; Smakhtin, V; Smirnov, S Yu; Smirnov, Y; Smirnova, L N; Smirnova, O; Smith, B C; Smith, D; Smith, K M; Smizanska, M; Smolek, K; Snesarev, A A; Snow, S W; Snow, J; Snuverink, J; Snyder, S; Soares, M; Sobie, R; Sodomka, J; Soffer, A; Solans, C A; Solar, M; Solfaroli-Camillocci, E; Solodkov, A A; Solovyanov, O V; Soluk, R; Sondericker, J; Sopko, V; Sopko, B; Sosebee, M; Sosnovtsev, V V; Sospedra-Suay, L; Soukharev, A; Spagnolo, S; Spanò, F; Speckmayer, P; Spencer, E; Spighi, R; Spigo, G; Spila, F; Spiwoks, R; Spousta, M; Spreitzer, T; Spurlock, B; St Denis, R D; Stahl, T; Stamen, R; Stancu, S N; Stanecka, E; Stanek, R W; Stanescu, C; Stapnes, S; Starchenko, E A; Stark, J; Staroba, P; Starovoitov, P; Stastny, J; Staude, A; Stavina, P; Stavropoulos, G; Steinbach, P; Steinberg, P; Stekl, I; Stelzer, B; Stelzer, H J; Stelzer-Chilton, O; Stenzel, H; Stevenson, K; Stewart, G; Stockton, M C; Stoerig, K; Stoicea, G; Stonjek, S; Strachota, P; Stradling, A; Straessner, A; Strandberg, J; Strandberg, S; Strandlie, A; Strauss, M; Strizenec, P; Ströhmer, R; Strom, D M; Strong, J A; Stroynowski, R; Strube, J; Stugu, B; Stumer, I; Soh, D A; Su, D; Suchkov, S I; Sugaya, Y; Sugimoto, T; Suhr, C; Suk, M; Sulin, V V; Sultansoy, S; Sumida, T; Sun, X; Sundermann, J E; Suruliz, K; Sushkov, S; Susinno, G; Sutton, M R; Suzuki, T; Suzuki, Y; Sviridov, Yu M; Sykora, I; Sykora, T; Szymocha, T; Sánchez, J; Ta, D; Tackmann, K; Taffard, A; Tafirout, R; Taga, A; Takahashi, Y; Takai, H; Takashima, R; Takeda, H; Takeshita, T; Talby, M; Talyshev, A; Tamsett, M C; Tanaka, J; Tanaka, R; Tanaka, S; Tanaka, S; Tappern, G P; Tapprogge, S; Tardif, D; Tarem, S; Tarrade, F; Tartarelli, G F; Tas, P; Tasevsky, M; Tassi, E; Taylor, C; Taylor, F E; Taylor, G N; Taylor, R P; Taylor, W; Teixeira-Dias, P; Ten Kate, H; Teng, P K; Terada, S; Terashi, K; Terron, J; Terwort, M; Testa, M; Teuscher, R J; Tevlin, C M; Thadome, J; Thananuwong, R; Thioye, M; Thoma, S; Thomas, J P; Thomas, T L; Thompson, E N; Thompson, P D; Thompson, P D; Thompson, R J; Thompson, A S; Thomson, E; Thun, R P; Tic, T; Tikhomirov, V O; Tikhonov, Y A; Timmermans, C J W P; Tipton, P; Tique-Aires-Viegas, F J; Tisserant, S; Tobias, J; Toczek, B; Todorov, T; Todorova-Nova, S; Toggerson, B; Tojo, J; Tokár, S; Tokushuku, K; Tollefson, K; Tomasek, L; Tomasek, M; Tomasz, F; Tomoto, M; Tompkins, D; Tompkins, L; Toms, K; Tong, G; Tonoyan, A; Topfel, C; Topilin, N D; Torrence, E; Torró Pastor, E; Toth, J; Touchard, F; Tovey, D R; Tovey, S N; Trefzger, T; Tremblet, L; Tricoli, A; Trigger, I M; Trincaz-Duvoid, S; Trinh, T N; Tripiana, M F; Triplett, N; Trivedi, A; Trocmé, B; Troncon, C; Trzupek, A; Tsarouchas, C; Tseng, J C-L; Tsiafis, I; Tsiakiris, M; Tsiareshka, P V; Tsionou, D; Tsipolitis, G; Tsiskaridze, V; Tskhadadze, E G; Tsukerman, I I; Tsulaia, V; Tsung, J-W; Tsuno, S; Tsybychev, D; Turala, M; Turecek, D; Turk Cakir, I; Turlay, E; Tuts, P M; Twomey, M S; Tylmad, M; Tyndel, M; Tzanakos, G; Uchida, K; Ueda, I; Uhlenbrock, M; Uhrmacher, M; Ukegawa, F; Unal, G; Underwood, D G; Undrus, A; Unel, G; Unno, Y; Urbaniec, D; Urkovsky, E; Urquijo, P; Urrejola, P; Usai, G; Uslenghi, M; Vacavant, L; Vacek, V; Vachon, B; Vahsen, S; Valenta, J; Valente, P; Valentinetti, S; Valkar, S; Valladolid Gallego, E; Vallecorsa, S; Valls Ferrer, J A; Van Berg, R; van der Graaf, H; van der Kraaij, E; van der Poel, E; Van Der Ster, D; van Eldik, N; van Gemmeren, P; van Kesteren, Z; van Vulpen, I; Vandelli, W; Vandoni, G; Vaniachine, A; Vankov, P; Vannucci, F; Varela Rodriguez, F; Vari, R; Varnes, E W; Varouchas, D; Vartapetian, A; Varvell, K E; Vasilyeva, L; Vassilakopoulos, V I; Vazeille, F; Vegni, G; Veillet, J J; Vellidis, C; Veloso, F; Veness, R; Veneziano, S; Ventura, A; Ventura, D; Venturi, M; Venturi, N; Vercesi, V; Verducci, M; Verkerke, W; Vermeulen, J C; Vetterli, M C; Vichou, I; Vickey, T; Viehhauser, G H A; Villa, M; Villani, E G; Villaplana Perez, M; Villate, J; Vilucchi, E; Vincter, M G; Vinek, E; Vinogradov, V B; Viret, S; Virzi, J; Vitale, A; Vitells, O V; Vivarelli, I; Vives Vaques, F; Vlachos, S; Vlasak, M; Vlasov, N; Vogt, H; Vokac, P; Volpi, M; Volpini, G; von der Schmitt, H; von Loeben, J; von Radziewski, H; von Toerne, E; Vorobel, V; Vorobiev, A P; Vorwerk, V; Vos, M; Voss, R; Voss, T T; Vossebeld, J H; Vranjes, N; Vranjes Milosavljevic, M; Vrba, V; Vreeswijk, M; Vu Anh, T; Vudragovic, D; Vuillermet, R; Vukotic, I; Wagner, P; Wahlen, H; Walbersloh, J; Walder, J; Walker, R; Walkowiak, W; Wall, R; Wang, C; Wang, H; Wang, J; Wang, J C; Wang, S M; Ward, C P; Warsinsky, M; Wastie, R; Watkins, P M; Watson, A T; Watson, M F; Watts, G; Watts, S; Waugh, A T; Waugh, B M; Webel, M; Weber, J; Weber, M D; Weber, M; Weber, M S; Weber, P; Weidberg, A R; Weingarten, J; Weiser, C; Wellenstein, H; Wells, P S; Wen, M; Wenaus, T; Wendler, S; Wengler, T; Wenig, S; Wermes, N; Werner, M; Werner, P; Werth, M; Werthenbach, U; Wessels, M; Whalen, K; Wheeler-Ellis, S J; Whitaker, S P; White, A; White, M J; White, S; Whiteson, D; Whittington, D; Wicek, F; Wicke, D; Wickens, F J; Wiedenmann, W; Wielers, M; Wienemann, P; Wiglesworth, C; Wiik, L A M; Wildauer, A; Wildt, M A; Wilhelm, I; Wilkens, H G; Williams, E; Williams, H H; Willis, W; Willocq, S; Wilson, J A; Wilson, M G; Wilson, A; Wingerter-Seez, I; Winklmeier, F; Wittgen, M; Wolter, M W; Wolters, H; Wosiek, B K; Wotschack, J; Woudstra, M J; Wraight, K; Wright, C; Wright, D; Wrona, B; Wu, S L; Wu, X; Wulf, E; Xella, S; Xie, S; Xie, Y; Xu, D; Xu, N; Yamada, M; Yamamoto, A; Yamamoto, S; Yamamura, T; Yamanaka, K; Yamaoka, J; Yamazaki, T; Yamazaki, Y; Yan, Z; Yang, H; Yang, U K; Yang, Y; Yang, Z; Yao, W-M; Yao, Y; Yasu, Y; Ye, J; Ye, S; Yilmaz, M; Yoosoofmiya, R; Yorita, K; Yoshida, R; Young, C; Youssef, S P; Yu, D; Yu, J; Yu, M; Yu, X; Yuan, J; Yuan, L; Yurkewicz, A; Zaidan, R; Zaitsev, A M; Zajacova, Z; Zambrano, V; Zanello, L; Zarzhitsky, P; Zaytsev, A; Zeitnitz, C; Zeller, M; Zema, P F; Zemla, A; Zendler, C; Zenin, O; Zenis, T; Zenonos, Z; Zenz, S; Zerwas, D; Zevi della Porta, G; Zhan, Z; Zhang, H; Zhang, J; Zhang, Q; Zhang, X; Zhao, L; Zhao, T; Zhao, Z; Zhemchugov, A; Zheng, S; Zhong, J; Zhou, B; Zhou, N; Zhou, Y; Zhu, C G; Zhu, H; Zhu, Y; Zhuang, X; Zhuravlov, V; Zilka, B; Zimmermann, R; Zimmermann, S; Zimmermann, S; Ziolkowski, M; Zitoun, R; Zivkovic, L; Zmouchko, V V; Zobernig, G; Zoccoli, A; zur Nedden, M; Zutshi, V

    2010-01-01

    The ATLAS liquid argon calorimeter has been operating continuously since August 2006. At this time, only part of the calorimeter was readout, but since the beginning of 2008, all calorimeter cells have been connected to the ATLAS readout system in preparation for LHC collisions. This paper gives an overview of the liquid argon calorimeter performance measured in situ with random triggers, calibration data, cosmic muons, and LHC beam splash events. Results on the detector operation, timing performance, electronics noise, and gain stability are presented. High energy deposits from radiative cosmic muons and beam splash events allow to check the intrinsic constant term of the energy resolution. The uniformity of the electromagnetic barrel calorimeter response along eta (averaged over phi) is measured at the percent level using minimum ionizing cosmic muons. Finally, studies of electromagnetic showers from radiative muons have been used to cross-check the Monte Carlo simulation. The performance results obtained u...

  15. Breakdown voltage of metal-oxide resistors in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Bagby, L. F. [Fermilab; Gollapinni, S. [Kansas State U.; James, C. C. [Fermilab; Jones, B. J.P. [MIT; Jostlein, H. [Fermilab; Lockwitz, S. [Fermilab; Naples, D. [Pittsburgh U.; Raaf, J. L. [Fermilab; Rameika, R. [Fermilab; Schukraft, A. [Fermilab; Strauss, T. [Bern U., LHEP; Weber, M. S. [Bern U., LHEP; Wolbers, S. A. [Fermilab

    2014-11-07

    We characterized a sample of metal-oxide resistors and measured their breakdown voltage in liquid argon by applying high voltage (HV) pulses over a 3 second period. This test mimics the situation in a HV-divider chain when a breakdown occurs and the voltage across resistors rapidly rise from the static value to much higher values. All resistors had higher breakdown voltages in liquid argon than their vendor ratings in air at room temperature. Failure modes range from full destruction to coating damage. In cases where breakdown was not catastrophic, subsequent breakdown voltages were lower in subsequent measuring runs. One resistor type withstands 131 kV pulses, the limit of the test setup.

  16. A pressurized argon gas TPC as DUNE near detector

    CERN Document Server

    Martin-Albo, J

    2016-01-01

    DUNE is a new international experiment for neutrino physics and nucleon decay searches. It will consist of two detectors, about 1300 km apart, exposed to a multi-megawatt neutrino beam that will be built at Fermilab. One of the two detectors will be installed several hundred meters downstream of the neutrino production point with the primary role of characterising the energy spectrum and composition of the beam as well as performing precision measurements of neutrino cross sections. For the design of this so-called near detector, the DUNE Collaboration is considering, among other technologies, a pressurized argon gas time projection chamber. Such a detector, thanks to its low density and low detection thresholds, would allow the detailed measurement in argon of nuclear effects at the neutrino interaction vertex, which are considered at present one of the most important sources of systematic uncertainty for neutrino oscillation measurements.

  17. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  18. Treatment of facial vascular lesions with an argon laser

    Science.gov (United States)

    Szymanczyk, Jacek; Golebiowska, Aleksandra; Michalska, I.

    1996-03-01

    Two-hundred-ninety-six patients with various vascular lesions of the face have been treated with argon laser LAK-1 in the Department of Dermatology Warsaw Medical Academy since April 1992. The diagnosis of the treated lesions was port-wine stains, multiple telangiectasiae and small, most often induced by trauma hemangioma cavernosum of the lip. Best results were achieved in the patients with small hemangiomas cavernosum of the lip and multiple telangiectasiae on the face. Cure rate in this group was 100%. In 112 port-wine stain cases fading of 50 - 75% comparing with the adjacent skin was achieved. With stress, the argon laser therapy is a method of choice for the treatment of hemangioma cavernosum, port-wine stains and multiple teleagiectasiae of the face.

  19. Development of cryogenic installations for large liquid argon neutrino detectors

    CERN Document Server

    Adamowski, M; Geynisman, M; Hentschel, S; Montanari, D; Nessi, M; Norris, B

    2015-01-01

    A proposal for a very large liquid argon (68,000 kg) based neutrino detector is being studied. To validate the design principles and the detector technology, and to gain experience in the development of the cryostats and the cryogenic systems needed for such large experiments, several smaller scale installations will be developed and implemented, at Fermilab and CERN. The cryogenic systems for these installations will be developed, constructed, installed and commissioned by an international engineering team. These installations shall bring the required cooling power under specific conditions to the experiments for the initial cool-down and the long term operation, and shall also guarantee the correct distribution of the cooling power within the cryostats to ensure a homogeneous temperature distribution within the cryostat itself. The cryogenic systems shall also include gaseous and liquid phase argon purification devices to be used to reach and maintain the very stringent purity requirements needed for these...

  20. Perspectives in the effective use of fluoride in Asia

    DEFF Research Database (Denmark)

    Petersen, P E; Phantumvanit, P

    2012-01-01

    services, in particular, exposure to disease prevention programs (Petersen, 2003, 2008a). Benefits of fluoride for caries prevention have been substantiated in many countries (Petersen and Lennon, 2004; Jones et al., 2005). In the second half of the 20th century, this focus shifted to the development...... and evaluation of fluoride toothpastes and rinses and, to a lesser extent, to alternatives to water fluoridation, such as salt and milk fluoridation. Most recently, efforts have been made to summarize this extensive database through systematic reviews of fluoride administration (McDonagh et al., 2000; Marinho et...... al., 2003; Australian Government, 2007). The Asian workshop held in Phan-Nga, Thailand, during March 22-24, 2011, aimed to discuss current information on fluoride and dental caries, as well as to try identifying barriers and opportunities that countries of Asia may have for implementing such programs...

  1. Adsorption of Fluoride Ion by Inorganic Cerium Based Adsorbent

    Institute of Scientific and Technical Information of China (English)

    Jiao Zhongzhi(焦中志); Chen Zhonglin; Yang Min; Zhang Yu; Li Guibai

    2004-01-01

    Excess of fluoride in drinking water is harmful to human health, the concentration of F- ions must be maintained in the range of 0.5 to 1.5 mg/L. An inorganic cerium based adsorbent (CTA) is developed on the basis of research of adsorption of fluoride on cerium oxide hydrate. Some adsorption of fluoride by CTA adsorbent experiments were carried out, and results showed that CTA adsorbent has a quick adsorption speed and a large adsorption capacity. Adsorption follows Freundlich isotherm, and low pH value helps fluoride removal. Some physical-chemical characteristics of CTA adsorbent were experimented, fluoride removal mechanism was explored, and results showed that hydroxyl group of CTA adsorbent played an important role in the fluoride removal.

  2. Fluoride contamination in rain water of Sigrauli region

    Energy Technology Data Exchange (ETDEWEB)

    Chaurasia, S.; Mishra, S.K. [Mahatma Gandhi Chitrakoot Gramodaya, Chitrakoot (India)

    2007-07-01

    In this paper fluoride was monitored in rain water during rainy season at seven locations of Sigrauli region in 2004. The sampling location covered the impact of industrial complex of the area, and its impact on surface water sources monitored for the fluoride, pH, and electrical conductivity. The higher concentration of fluoride in rain water was observed 2.03 mg/L at Dudhar and in ponds water highest value was 3.14 mg/L. This suggested that serious fluoride pollution is occurring in Singrauli region posing a threat to the health and livelihood of the people of the region. Fluoride transported by the air route from coal burning emissions of large thermal power plants concentrate in small geographical area, and industries. Fluoride pollution in Singrauli area deserve intensive scientific studies and urgent attention. 2 figs., 2 tabs.

  3. Distribution of fluoride in ground water of West Virginia

    Science.gov (United States)

    Mathes, M.V.; Waldron, M.C.

    1993-01-01

    This report describes the results of a study by the U.S. Geological Survey, in cooperation with the West Virginia Geological and Economic Survey, to evaluate the distribution of fluoride in ground water of West Virginia. Fluoride is a natural chemical constituent in domestic and public water supplies in West Virginia. Fluoride concentrations of about 1.0 milligram per liter in drinking water are beneficial to dental health. Concentrations greater than 2.0 milligrams per liter, however, could harm teeth and bones. Fluoride concentra- tions in ground water of West Virginia range from less than 0.1 to 12 milligrams per liter. Fluoride concentrations that exceed 2.0 milligrams per liter are found in wells drilled to all depths, wells drilled in all topographic settings, and wells drilled into most geologic units. Most fluoride concentrations that exceed 2.0 milligrams per liter are located at sites clustered in the northwestern part of the State.

  4. Viscosity estimation for slags containing calcium fluoride

    Institute of Scientific and Technical Information of China (English)

    Qifeng Shu; Jiayun Zhang

    2005-01-01

    Based on recently published experimental data, the Riboud model was modified for viscosity estimation of the slags containing calcium fluoride. The estimated values were in good agreement with measured data. Reasonable estimation can be achieved using the modified Riboud model for mould fluxes and ESR (eletro slag remelting) slags. Especially for ESR slags, the modified Riboud model can provide much more precise values than the original Riboud model.

  5. Fluoride solid electrolytes containing rare earth elements

    Institute of Scientific and Technical Information of China (English)

    Viera Trnovcová; Pavel P. Fedorov; Ivan Furár

    2008-01-01

    Relations between the structure, ionic conductivity and dielectric properties of fluoride systems of different structures containing rare earth elements were presented. Superionic conductivities, by fluoride ions, of fluorite-structured (MF2-REF3, M=Ba, Pb, RE=La-Lu, Sc, Y), orthorhombic (REF3, RE=Tb-Er,Y), tysonite-structured (REF3-MF2, RE=La-Nd, M=Sr), monoclinic (BaRE2F8, RE=Ho-Yb, Y) fluoride single crystals and eutectic composites (LiF-REF3, RE=La-Gd,Y) were compared. Anisotropy of electrical properties of crystals with a lower symmetry was explained by modeling optimum ionic paths. For explanation of concentration dependences of fast ionic conductivity, models of aggregation of defects into clusters were proposed. In fluorite-structured crystals, the highest ionic conductivity was found for PbF2: 7 mol% ScF3 (at 500 K, σ500=0.13 S/cm). In tysonite-structured crystals, the highest ionic conductivity was found for LaF3: 3 mol% SrF2 (σ500=2.4×10-2 S/cm). Different types of coordination polyhedrons and their different linking in orthorhombic and tysonite structure explained large differences between conductivities in both structures. Eutectic systems, prepared as directionally solidified composites, enabled to study some orthorhombic fluoride phases (GdF3, SmF3), which cannot be prepared as single crystals. An influence of the orthorhombic-tysonite phase transition on the ionic conductivity was shown.

  6. Effect of fluoride toothpastes on enamel demineralization

    Directory of Open Access Journals (Sweden)

    Gintner Zeno

    2006-06-01

    Full Text Available Abstract Background It was the aim of this study to investigate the effect of four different toothpastes with differing fluoride compounds on enamel remineralization. Methods A 3 × 3 mm window on the enamel surface of 90 human premolars was demineralized in a hydroxyethylcellulose solution at pH 4.8. The teeth were divided into 6 groups and the lower half of the window was covered with varnish serving as control. The teeth were immersed in a toothpaste slurry containing: placebo tooth paste (group 1; remineralization solution (group 2; Elmex Anticaries (group 3; Elmex Sensitive (group 4; Blend-a-med Complete (group 5 and Colgate GRF (group 6. Ten teeth of each group were used for the determination of the F- content in the superficial enamel layer and acid solubility of enamel expressed in soluble phosphorus. Of 6 teeth of each group serial sections were cut and investigated with polarization light microscopy (PLM and quantitative energy dispersive X-ray analysis (EDX. Results The PLM results showed an increased remineralization of the lesion body in the Elmex Anticaries, Elmex Sensitive and Colgate GRF group but not in the Blend-a-med group. A statistically significant higher Ca content was found in the Elmex Anticaries group. The fluoride content in the superficial enamel layer was significantly increased in both Elmex groups and the Blend-a-med group. Phosphorus solubility was significantly decreased in both Elmex groups and the Blend-a-med group. Conclusion It can be concluded that amine fluoride compounds in toothpastes result in a clearly marked remineralization of caries like enamel lesions followed by sodium fluoride and sodium monofluorophosphate formulations.

  7. Health protection: Fluoridation and dental health.

    OpenAIRE

    1983-01-01

    Tooth decay, which affects 95 percent of Americans, is our most common health problem, costing an estimated +2 billion yearly for treatment. By the time children reach 17 years of age, 94 percent have experienced caries and 36 percent have lost one or more permanent teeth due to caries. Dental disease prevention embodies the spectrum of many activities from the fluoridation of community and school water supplies to the dental health education of the child and adult. At this stage of our knowl...

  8. Delivery Challenges for Fluoride, Chlorhexidine and Xylitol

    OpenAIRE

    Featherstone, John DB

    2006-01-01

    The progression or reversal of dental caries is determined by the balance between pathological and protective factors. It is well established that a) fluoride inhibits demineralization and enhances remineralization, b) chlorhexidine reduces the cariogenic bacterial challenge, and c) xylitol is non-cariogenic and has antibacterial properties. The challenge that we face is how best to deliver these anti-caries entities at true therapeutic levels, over time, to favorably tip the caries balance. ...

  9. Spectroscopy of Argon Excited in an Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E

    2005-04-18

    Argon is one of the gases best investigated and most widely used in plasma discharge devices for a multitude of applications that range from wavelength reference standards to controlled fusion experiments. Reviewing atomic physics and spectroscopic problems in various ionization stages of Ar, the past use and future options of employing an electron beam ion trap (EBIT) for better and more complete Ar data in the x-ray, EUV and visible spectral ranges are discussed.

  10. Influence of argon pollution on the weld surface morphology

    OpenAIRE

    Krolczyk, G.M.; Nieslony, P.; Krolczyk, J.B.; I. Samardzic; Legutko, S.; S. Hloch; Barrans, Simon; Maruda, R.W.

    2015-01-01

    In this paper the surfaces of butt welded joints in steel tubes were analyzed using an optical 3D measurement system to determine the morphology and topographic parameters. It was established that pollution of the argon shield gas with oxygen did not influence the width of the heat-affected zone. However, the composition of the shield gas significantly influenced the surface asymmetry, Ssk, and its inclination Sku. The measurement of these parameters enabled the selection of a ...

  11. STATUS OF THE ATLAS LIQUID ARGON CALORIMETER AND ITS PERFORMANCE

    CERN Document Server

    Berillari, T; The ATLAS collaboration

    2011-01-01

    The liquid argon (LAr) calorimeters are used in ATLAS for all electromagnetic and for hadron calorimetry. The LAr calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic, hadronic and forward calorimeters. The latest status of the detector as well as problems and solutions addressed during the last years will be presented. Aspects of operation of a large detector over a long time period will be summarized and selected topics showing the performance of the detector will be shown.

  12. Thermal decomposition of lanthanum(III) butyrate in argon atmosphere

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Xiao, Tang;

    2013-01-01

    The thermal decomposition of La(C3H7CO2)3·xH2O (x≈0.82) was studied in argon during heating at 5K/min. After the loss of bound H2O, the anhydrous butyrate presents at 135°C a phase transition to a mesophase, which turns to an isotropic liquid at 180°C. The decomposition of the anhydrous butyrate ...

  13. Operational performance of a large liquid argon photon calorimeter

    International Nuclear Information System (INIS)

    We describe the performance of a large (0.9x1.4 m2) liquid argon photon calorimeter in high energy experiments at Fermilab. Resolutions for π0 and electron showers, obtained under data-taking conditions, are compared with electron-beam calibration results. Exceptional spatial and time resolutions have been achieved for isolated showers (sigmasub(x,y)0 data up to 180 GeV are presented. (orig.)

  14. Unified set of atomic transition probabilities for neutral argon

    OpenAIRE

    Wiese, W.; Brault, J.; Danzmann, K.; Helbig, V.; de Kock, M

    1989-01-01

    The atomic transition probabilities and radiative lifetimes of neutral argon have been the subject of numerous experiments and calculations, but the results exhibit many discrepancies and inconsistencies. We present a unified set of atomic transition probabilities, which is consistent with essentially all recent results, albeit sometimes only after critical reanalysis. The data consistency and scale confirmation has been achieved in two ways. (i) We have carried out some lifetime–branching-ra...

  15. Monte Carlo Simulation of Argon in Nano-Space

    Institute of Scientific and Technical Information of China (English)

    CHEN Min; YANG Chun; GUO Zeng-Yuan

    2000-01-01

    Monte Carlo simulations are performed to investigate the thermodynamic properties of argon confined in nano-scale cubes constructed of graphite walls. A remarkable depression of the system pressures is observed. The simulations reveal that the length-scale of the cube, the magnitude of the interaction between the fluid and the graphite wall and the density of the fluid exhibit reasonable effects on the thermodynamic property shifts of the luid.

  16. Biological effects data: Fluoride and sulfur dioxide

    Energy Technology Data Exchange (ETDEWEB)

    McMechan, K.J. (ed.); Holton, R.L.; Ulbricht, R.J.; Morgan , J.B.

    1975-04-01

    The Alumax Pacific Aluminum Corporation has proposed construction of an aluminum reduction facility near Youngs Bay at Warrenton, Oregon. This report comprises one part of the final report to Alumax on a research project entitled, Physical, Chemical and Biological Studies of Youngs Bay.'' It presents data pertaining to the potential biological effects of fluoride and sulfur dioxide, two potentially hazardous plant-stack emissions, on selected aquatic species of the area. Companion volumes provide a description of the physical characteristics the geochemistry, and the aquatic animals present in Youngs Bay and adjacent ecosystems. An introductory volume provides general information and maps of the area, and summarizes the conclusions of all four studies. The data from the two phases of the experimental program are included in this report: lethal studies on the effects of selected levels of fluoride and sulfur dioxide on the survival rate of eleven Youngs Bay faunal species from four phyla, and sublethal studies on the effects of fluoride and sulfur dioxide on the rate of primary production of phytoplankton. 44 refs., 18 figs., 38 tabs.

  17. Bone scintigraphy in fluoride treated osteoporosis

    International Nuclear Information System (INIS)

    Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. They also demonstrate the utility of serial quantitative bone scintigraphy in assessing osteoporotic patients with vertebral compression fractures

  18. How and when to prescribe sodium fluoride.

    Science.gov (United States)

    Shambaugh, G E

    1989-03-01

    Sodium fluoride has now been used for 24 years in an effort to slow down or arrest sensorineural hearing nerve deterioration in patients with stapedial otosclerosis or after stapedectomy, as well as in patients with pure cochlear otosclerosis. Extensive clinical experience in thousands of patients with this therapy has demonstrated its value in arresting previously progressive sensorineural hearing loss. For a long time there were those who objected to this therapy on the basis that it had not been adequately proven by double-blind, placebo-controlled studies. They have been answered by Bretlau's study in Denmark and Fisch's from Switzerland; both investigators confirmed on small groups the value of sodium fluoride by double-blind, placebo-controlled studies. Extensive research by Professor Petrovic of Strasbourg while at our tissue culture laboratory at Northwestern University demonstrated the action of sodium fluoride on bone. A nicely designed study with radioactive strontium by Linthicum, House, and Althaus demonstrated its value in promoting maturation of a spongiotic focus. Today there is no reason to hesitate in prescribing this useful, effective, and safe medication to promote maturation of otospongiotic lesions, and thus to slow down or to arrest progression in sensorineural hearing loss.

  19. Two dimensional condensation of argon adsorbed on lamellar halides

    International Nuclear Information System (INIS)

    Lamellar halides such as NiCl2, FeCl2, NiBr2, MnBr2, MgBr2, CdBr2, CoI2, FeI2, MnI2, CaI2 and PbI2 were sublimed in a rapid stream of dry nitrogen. The adsorption of argon on such materials shows stepped isotherms which reveal two dimensional condensations. From sets of isotherms the Helmholtz free energy, the internal energy and the entropy of the successive layers are determined. From the entropy of the first layer the role of the potential relief of the adsorbent surface on the structure of the adsorbed layer may be determined while the Helmholtz free energy reveals how the ionic character of the adsorbent governs the attractive force of adsorption. The study of the second third and fourth layers shows that their growth follows quite a different behaviour depending on whether the Van der Waals diameter of argon is greater or smaller than the distance between adjacent anions on the crystal surface. A proposition is made to account for the difference in the critical temperatures of the first and second dense layers in terms of the vibrationnal state of their respective substrate. The occurence for the maximum critical temperature observed of corresponding to a triangular layer 3% more expanded than the (111) plane of solid argon is discussed

  20. A liquid argon scintillation veto for the Gerda experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Bare germanium detectors are operated in a cryostat with 65 m{sup 3} of liquid argon (LAr). To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Q{sub ββ} at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  1. A liquid argon scintillation veto for the Gerda experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Bare germanium detectors are operated in a cryostat with 65 m3 of liquid argon (LAr). To reach the aspired background index of ≤10-3 cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Qββ at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  2. Space-charge effects in liquid argon ionization chambers

    Science.gov (United States)

    Rutherfoord, J. P.; Walker, R. B.

    2015-03-01

    We have uniformly irradiated liquid argon ionization chambers with betas from high-activity 90Sr sources. The radiation environment is similar to that in the liquid argon calorimeters which are part of the ATLAS detector installed at CERN's Large Hadron Collider (LHC). We measured the resulting ionization current over a wide range of applied potential for two different source activities and for three different chamber gaps. These studies provide operating experience at exceptionally high ionization rates. In particular they indicate a stability at the 0.1% level for these calorimeters over years of operation at the full LHC luminosity when operated in the normal mode at an electric field E = 1.0 kV / mm. We can operate these chambers in the normal mode or in the space-charge limited regime and thereby determine the transition point between the two. This transition point is parameterized by a positive argon ion mobility of μ+ = 0.08 ± 0.02mm2 / V s at a temperature of 88.0±0.5 K and at a pressure of 1.02±0.02 bar. In the space-charge limited regime the ionization currents are degraded and show signs of instability. At the highest electric fields in our study (6.7 kV/mm) the ionization current is still slowly rising with increasing electric field.

  3. ARAPUCA a new device for liquid argon scintillation light detection

    International Nuclear Information System (INIS)

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R and D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors

  4. Isotopic fractionation of argon during stepwise release from shungite

    International Nuclear Information System (INIS)

    In previous attempts to determine the 40Ar/36Ar ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite, an amorphous carbon mineral The present work confirms a low value for 40Ar/36Ar in gas released from a type I shungite at low temperatures. But quantitative scrutiny of the accompanying 38AR/36Ar ratios and the enhanced ratio of 40Ar/36Ar for the fractions released at high temperatures shows convincingly that the effect seen here is an artifact of the stepwise heating and the argon diffusion mobilized thereby. The low 40Ar/36Ar previously obtained is very likely from the same cause rather than reflecting the isotopic composition of the pre-Cambrian atmosphere. The vitreous character of and the sharp, conchoidal fractures seen in the specimens of type I shungite suggest that the substance may exhibit simple volume diffusion over macroscopic dimensions as glasses do. If so, the diffusion parameters (D infinitely = 3 x 10-4 cm2/s and E = 11 kcal/mole) obtained from the data imply rapid exchange with the atmosphere for any argon initially trapped in centimenter-thick veins of the material. (orig.)

  5. Isotopic fractionation of argon during stepwise release from shungite

    Science.gov (United States)

    Rison, W.

    1980-05-01

    It is noted that in previous attempts to determine the Ar-40/Ar-36 ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite. In the present work, a low value for Ar-40/Ar-36 in gas released from a type I shungite at low temperatures is confirmed. Attention is given to a study of the accompanying Ar-38/Ar-36 ratios and the enhanced ratio of Ar-40/Ar-36 for the fractions released at high temperatures which shows that the effect observed is a result of the stepwise heating and the argon diffusion mobilized thereby. It is suggested that the low Ar-40/Ar-36 obtained in the past is from the same source rather than reflecting the isotropic composition of the pre-Cambrian atmosphere, and that the type I shungite may exhibit simple volume diffusion over macroscopic dimensions as glasses do. It is concluded that if this is so, the diffusion parameters obtained from the data would imply rapid exchange with the atmosphere for any argon initially trapped in the veins of the material.

  6. Tin LPP plasma control in the argon cusp source

    Science.gov (United States)

    McGeoch, Malcolm W.

    2016-03-01

    The argon cusp plasma has been introduced [1,2] for 500W class tin LPP exhaust control in view of its high power handling, predicted low tin back-scatter from a beam dump, and avoidance of hydrogen usage. The physics of tin ion control by a plasma is first discussed. Experimentally, cusp stability and exhaust disc geometry have previously been proved at full scale [2], the equivalent of 300W-500W usable EUV. Here we verify operation of the plasma barrier that maintains a high argon density next to the collector, for its protection, and a low density in the long path toward the intermediate focus, for efficiency. A pressure differential of 2Pa has been demonstrated in initial work. Other aspects of tin LPP plasma control by the cusp have now been demonstrated using tin ions from a low Hz 130mJ CO2 laser pulse onto a solid tin surface at the cusp center. Plasma is rejected at the design to match a specified exhaust power is discussed. In view of this work, argon cusp exhaust control appears to be very promising for 500W class tin LPP sources.

  7. Bacteria Inactivation Using DBD Plasma Jet in Atmospheric Pressure Argon

    Institute of Scientific and Technical Information of China (English)

    XU Guimin; ZHANG Guanjun; SHI Xingmin; MA Yue; WANG Ning; LI Yuan

    2009-01-01

    A coaxial dielectric barrier discharge plasma jet Was designed,which can be operated in atmospheric pressure argon under an intermediate frequency sinusoidal resonant power supply,and an atmospheric pressure glow-like discharge Was achieved.Two kinds of typical bacteria,i.e.,the Staphylococcus aureus(S.aurens)and Escherichia coil(E.coil),were employed to study the bacterial inactivation mechanism by means of the non-thermal plasma.The killing log value (KLV)of S.aureus reached up to 5.38 with a treatment time of 90 s and that of E.coil up to 5.36 with 60 s,respectively.According to the argon emission spectra of the plasma jet and the scanning electron microscope (SEM) images of the two bacteria before and after the plasma treatment.it is concluded that the reactive species in the argon plasma played a major role in the bacterial inactivation,while the heat,electric field and UV photons had little effect.

  8. Metal clusters on supported argon layers; Metallcluster auf dielektrischen Substraten

    Energy Technology Data Exchange (ETDEWEB)

    Faber, Bernhard

    2011-10-21

    The deposition of small sodium clusters on supported Ar(001)-surfaces is simulated. Theoretical description is achieved by a hierarchical model consisting of time-dependent DFT and molecular dynamics. The valence electrons of the sodium atoms are considered by Kohn-Sham-Scheme with self interaction correction. The interaction of argon atoms and sodium ions is described by atom-atom potentials whereas the coupling to the QM electrons is done by local pseudo-potentials. A decisive part of the model is the dynamical polarizability of the rare-gas atoms. The optional metal support is considered by the method of image charges. The influence of the forces caused by image charges and the influence of the number of argon monolayers on structure, optical response and deposition dynamics of Na{sub 6} and Na{sub 8} is investigated. There is very little influence on cluster structure and only a small shift of the cluster perpendicular to the surface. Concerning optical response the position of the Mie plasmon peak stays robust whereas the details of spectral fragmentation react very sensitively to changes. The forces caused by image charges of the metal support play only a little role with the dynamics of deposition while the thickness of the argon surface strongly influences the dissipation. (orig.)

  9. Mortality and cancer morbidity after heavy occupational fluoride exposure

    DEFF Research Database (Denmark)

    Grandjean, P; Juel, K; Jensen, Ole Møller

    1985-01-01

    A cohort of 431 male cryolite workers employed for at least six months between 1924 and 1961 was identified from personnel records at the Copenhagen cryolite factory. During this period, heavy fluoride exposure resulted in at least 74 cases of skeletal fluorosis. All workmen in the cohort were......, a possible residual effect of fluoride cannot be excluded. However, any major carcinogenic effect of heavy fluoride exposure would be very unlikely....

  10. 40 CFR 60.202 - Standard for fluorides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.202 Section... Industry: Wet-Process Phosphoric Acid Plants § 60.202 Standard for fluorides. (a) On and after the date on... facility any gases which contain total fluorides in excess of 10.0 g/Mg of equivalent P2O5 feed (0.020...

  11. 40 CFR 60.192 - Standard for fluorides.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.192 Section... Plants § 60.192 Standard for fluorides. (a) On and after the date on which the initial performance test... total fluorides, as measured according to § 60.195, in excess of: (1) 1.0 kg/Mg (2.0 lb/ton) of...

  12. The status of community water fluoridation in the United States.

    OpenAIRE

    Easley, M W

    1990-01-01

    Community water fluoridation has served the American public extremely well as the cornerstone of dental caries prevention activities for 45 years. The dental and general health benefits associated with the ingestion of water-borne fluorides have been well known by researchers for an even longer period. Continued research has repeatedly confirmed the safety, effectiveness, and efficiency of community water fluoridation in preventing dental caries for Americans regardless of age, race, ethnicit...

  13. LiFePO_4/C via fluoride doping

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Non-stoichiometric compound fluoride-doped LiFePO4/C cathode materials were synthesized via solid-state reaction using MgF2 and AlF3 as dopant. The fluoride-doped LiFePO4/C samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and electrochemical testing. The results show that the materials are well crystallized and fluoride doping cannot change the space structure of LiFePO4. Slight amounts of Fe2O3 with no fluoride impurity were ...

  14. Sodium fluoride influences the expression of keratins in cultured keratinocytes

    OpenAIRE

    Prado, Euridice; Wurtz, Tilmann; Ferbus, Didier; Shabana, El-Hassan; FOREST, Nadine; Berdal, Ariane

    2010-01-01

    Epithelia in lung, skin, and kidney are often exposed to fluoride, and tissue damage in lung and kidney due to fluoride is well documented. Nevertheless, the biological effects of fluoride on epithelia are poorly investigated. In the present study, we report effects of sodium fluoride (NaF) on the differentiation of a human epithelial cell line, HaCaT. These cells may serve as a keratinocyte model, because they express a wide spectrum of keratins (Ks), and they associate into stratified tissu...

  15. Fluoride content in caffeinated, decaffeinated and herbal teas.

    Science.gov (United States)

    Chan, J T; Koh, S H

    1996-01-01

    The fluoride contents of infusions prepared from 44 different brands and types of teas were measured. Fluoride concentrations ranged from 0.34 to 3.71 ppm (mean = 1.50 ppm) in caffeinated tea infusions, 0.02-0.14 ppm (mean = 0.05 ppm) in herbal tea infusions, and 1.01-5.20 ppm (mean = 3.19) in decaffeinated tea infusions. This is the first report of the fluoride content of decaffeinated teas. The mean fluoride content of decaffeinated tea infusions is significantly (p decaffeination is the most likely explanation of the above observation.

  16. Effects of oral doses of fluoride on nestling European starlings

    Science.gov (United States)

    Fleming, W.J.; Grue, C.E.; Schuler, C.A.; Bunck, C.M.

    1987-01-01

    Nestling European starlings (Sturnus vulgaris), raised and fed by free-living adults, were given daily oral doses of either distilled water, 193 mg sodium as Na2CO3 per kg of body weight (sodium control group), or 6, 10, 13, 17,23, 30, 40, 80, 160 mg of the fluoride ion as NaF in distilled water per kg of body weight (mg/kg). Dosing began when nestlings were 24-48 hr old and continued for 16 days. The 24-hr LD50 of fluoride for day-old starlings was 50 mg/kg. The 16-day LD50 was 17 mg/kg. The sodium control group did not differ from the water control group with respect to any of the measured variables. Growth rates were significantly reduced in the 13 and 17 mg of fluoride/kg groups; weights of birds given higher dose levels were omitted from growth comparisons because of high, fluoride-induced mortality. Although pre-fledging weights for the 10, 13, and 17 mg of fluoride/kg groups averaged 3.6 to 8.6% less than controls at 17 days, this difference was not significant. Feather and bone growth of the fluoride and control groups were not different, except for keel length measured at 17 days of age which averaged less in the fluoride groups. Liver and spleen weights were not affected by fluoride treatments. No histological damage related to fluoride treatments was found in liver, spleen, or kidney. The logarithm of bone fluoride and magnesium concentration increased with the logarithm of increasing fluoride treatment levels and were significantly correlated with each other. Fluoride treatments had no effect on percent calcium or phosphorus in bone or plasma alkaline phosphatase activity. Oral doses of fluoride appear to be more toxic than equivalent dietary levels. Most birds probably acquire fluoride through their diet. Therefore, the results of the study may overestimate the potential effects of fluorides on songbirds living in fluoride-contaminated environments.

  17. Oxidative stress in cases of chronic fluoride intoxication

    OpenAIRE

    Ailani, Vinita; R. C. Gupta; Gupta, Sunil Kumar; Gupta, Kapil

    2009-01-01

    This study was conducted to find out the level of oxidative stress and effect of supplementation of vitamin C, D and Calcium on levels of SOD, serum and urinary fluoride in children residing in endemic fluorosis area. For this the fluoride belt of Jaipur district was selected. The parameters selected were Super oxide dismutase, serum fluoride and urinary fluoride. The study was conducted on one hundred children, selected from four areas (25 from each area) consuming water containing 1.2, 2.4,...

  18. K-Ar age of young volcanic rocks and excess argon--Binary mixing model and quantitative study of excess argon effect

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A binary mixing model for excess argon is suggested in the note. According to this model and the data of excess argon component obtained in our experiment , a quantitative study of the effect of excess argon on real K-Ar age of young volcanic rocks is done. The result indicates that the effect of 5% excess argon component in samples on K-Ar age of the samples more than 2 Ma is less than 7.36% and can lead K-Ar age of 0.5 Ma samples to increase by 32.4%, while 1% excess argon component leads K-Ar age of 0.5 Ma samples to increase by 6.26%. Therefore, when pre-processed excess argon component is ≤1%, K-Ar age of the samples more than 0.5 Ma should be credible. On this basis we suggest a principal opinion for evaluation of previous K-Ar dating results and propose that the matrix is used to determine K-Ar age of young volcanic rocks. For the samples less than 0.2 Ma, in the case of high excess argon content, even if only 1% excess argon component exists in their matrix, it can also greatly affect their K-A age. Thus it must be careful to treat the dating result.

  19. Total Fluoride Intake and Urinary Excretion in German Children Aged 3–6 Years

    OpenAIRE

    Haftenberger, Marjolein; Viergutz, Gabriele; Neumeister, Volker; Hetzer, Gisela

    2014-01-01

    There have only been few investigations comparing total fluoride intake and the fluoride proportion excreted in urine in pre–school children. In addition, the results of available studies are conflicting. Total fluoride intake was assessed in 11 healthy children aged 3–6 years on 2 consecutive days and urinary fluoride excretion was determined. The duplicate–diet approach was used for the assessment of fluoride intake from solid and liquid foods. Fluoride intake from toothbrushing was calcula...

  20. Cariostatic effect of fluoride-containing restorative materials associated with fluoride gels on root dentin

    Directory of Open Access Journals (Sweden)

    Fernanda Tavares Borges

    2010-10-01

    Full Text Available Secondary caries is still the main cause of restoration replacement, especially on the root surface OBJECTIVE: This in vitro study evaluated the cariostatic effects of fluoride-containing restorative materials associated with fluoride gels, on root dentin. MATERIALS AND METHODS: A randomized complete block design was used to test the effects of the restorative systems, fluoride regimes and the interactions among them at different distances from restoration margins. Standardized cavities were prepared on 240 bovine root specimens and randomly assigned to 15 groups of treatments (n=16. Cavities were filled with the following restorative materials: Ketac-Fil (3M-ESPE; Vitremer (3M-ESPE; Dyract/Prime & Bond NT (Dentsply; Charisma/Gluma One Bond (Heraeus Kulzer and the control, Z250/Single Bond (3M-ESPE. The specimens were subjected to a pH-cycling model designed to simulate high-caries activity. During the cycles, 1.23% acidulated phosphate fluoride, 2.0% neutral sodium fluoride or deionized/distilled water (control was applied to the specimens for 4 min. The surface Knoop microhardness test was performed before (KHNi and after (KHNf the pH cycles at 100, 200 and 300 mm from the margins. Dentin microhardness loss was represented by the difference in initial and final values (KHNi - KHNf. Data were analyzed by Friedman's and Wilcoxon's tests, ANOVA and Tukey's test (α=5%. RESULTS: The interaction of restorative systems and topical treatments was not significant (p=0.102. Dentin microhardness loss was lowest closer to the restoration. Ketac-fil presented the highest cariostatic effect. Vitremer presented a moderate effect, while Dyract and Charisma did not differ from the control, Z250. The effects of neutral and acidulated fluoride gels were similar to each other and higher than the control. CONCLUSION: Conventional and resin-modified glass ionomer cements as well as neutral and acidulated fluoride gels inhibit the progression of artificial caries

  1. Roles of argon seeding in energy confinement and pedestal structure in JT-60U

    International Nuclear Information System (INIS)

    The mechanism of improving energy confinement with argon seeding at high density has been investigated in JT-60U. Better confinement is sustained at high density by argon seeding accompanied by higher core and pedestal temperatures. The electron density profiles become flatter with increasing density in conventional H-mode plasmas, whereas peaked density profiles are maintained with argon seeding. Density peaking and dilution effects lower the pedestal density at a given averaged density. The pedestal density in the argon seeded plasmas, which is lower than that in plasmas with deuterium puff, enables the pedestal temperature to be higher, whereas the increase in the pedestal pressure with argon seeding is small. High pedestal temperature is a boundary condition for high core temperature through profile stiffness, which leads to better confinement with argon seeding. The density peaking is a key factor of sustaining better confinement in argon seeded H-mode plasmas. The radiative loss power density is predominantly enhanced in the edge region by argon puff. The role of argon seeding in the pedestal characteristics has also been examined. The pedestal width becomes larger continuously with edge collisionality, but is nearly independent of the presence of argon seeding. (paper)

  2. Argon-41 production and evolution at the Oregon State University TRIGA Reactor (OSTR)

    International Nuclear Information System (INIS)

    In this study, argon-41 concentrations were measured at various locations within the reactor facility to assess the accuracy of models used to predict argon-41 evolution from the reactor tank, and to determine the relationship between argon gas evolution from the tank and subsequent argon-41 concentrations throughout the reactor room. In particular, argon-41 was measured directly above the reactor tank with the reactor tank lids closed, at other accessible locations on the reactor top with the tank lids both closed and open, and at several locations on the first floor of the reactor room. These measured concentrations were then compared to values calculated using a modified argon-41 production and evolution model for TRIGA reactor tanks and ventilation values applicable to the OSTR facility. The modified model was based in part on earlier TRIGA models for argon-41 production and release, but added features which improved the agreement between predicted and measured values. The approximate dose equivalent rate due to the presence of argon-41 in reactor room air was calculated for several different locations inside the OSTR facility. These dose rates were determined using the argon-41 concentration measured at each specific location, and were subsequently converted to a predicted quarterly dose equivalent for each location based on the reactor's operating history. The predicted quarterly dose equivalent values were then compared to quarterly doses measured by film badges deployed as dose-integrating area radiation monitors at the locations of interest. The results indicate that the modified production and evolution model is able to predict argon-41 concentrations to within a factor of ten when compared to the measured data. Quarterly dose equivalents calculated from the measured argon-41 concentrations and the reactor's operating history seemed consistent with results obtained from the integrating area radiation monitors. Given the argon-41 concentrations measured

  3. Volatile Single-Source Precursors for the Low-Temperature Preparation of Sodium-Rare Earth Metal Fluorides.

    Science.gov (United States)

    Barry, Matthew C; Wei, Zheng; He, Tianyu; Filatov, Alexander S; Dikarev, Evgeny V

    2016-07-20

    Heterometallic single-source precursors for the preparation of sodium-rare earth metal fluorides are reported. Fluorinated β-diketonates NaRE(hfac)4 (RE = Y (1), Er (2), and Eu (3); hfac = hexafluoroacetylacetonate) have been obtained on a large scale, in high yield, via one-pot reaction that utilizes commercially available starting reagents. The solid-state structures of the title complexes consist of 1D polymeric chains with alternating [Na] and [RE(hfac)4] units. Compounds 1-3 are highly volatile and exhibit a fair stability in open air. Mass spectrometric investigation indicates the presence of heterometallic fragments in the gas phase. The presence of heterometallic species in solutions of coordinating solvents has also been confirmed. Decomposition of heterometallic precursors in argon atmosphere was shown to yield phase-pure sodium-rare earth metal fluorides. Low decomposition temperature effectively allows for a high degree of control over the formation of both kinetic α-phases and thermodynamic β-phases of target NaREF4 (RE = Y, Er, and Eu) materials. PMID:27232230

  4. Determination of Fluoride in Toothpaste Using an Ion-Selective Electrode

    Science.gov (United States)

    Light, Truman S.; Cappuccino, Carleton C.

    1975-01-01

    Outlines the theory of chemical potentiometry, describes the experimental procedure for free fluoride determination, and presents sample data of fluoride concentration for various brands of toothpaste. (GS)

  5. PREPARATION AND CHARACTERIZATION OF STRONTIUM FLUORIDE POWDERS ACTIVATED BY NEODYMIUM FLUORIDE

    Directory of Open Access Journals (Sweden)

    S. V. Kuznetsov

    2015-07-01

    Full Text Available Subject of Study. The paper deals with preparation processes of ultradisperse, homogeneous powder Sr1-хNdхF2+х (х= 0.003-0.2, with use of ammonium fluoride as the fluorinating agent taken over 114-120 % from stoichiometry. Method. Nitrate of strontium, neodymium nitrate hexahydrate, with the content equal to 99. 99 % of the basic substance and ammonium fluoride were used as the source of substances. Activated powders of strontium fluoride were obtained by the method of deposition from aqueous solutions by washing the precipitate with a solution of ammonium fluoride, taken over 114 - 120% from stoichiometry. The washed precipitate was centrifuged for 5-7 min, dried in the air at 30-350 C. Heat treatment of the dried precipitate was carried out in two stages: the first stage at the temperature of 200- 2500 C for 0.5-1 hour, the second one at 550- 6000 C for 2-3 hours. X-ray analysis of the synthesized samples was carried out on a Bruker D8 Advance diffractometer, radiation Cu K. The size and shape measuring of the particles of activated strontium fluoride was carried out by means of electron microscope Carl Zeiss NVision 40. The content of neodymium in activated powders of strontium fluoride was determined by the method of spectral emission analysis on the device LEA - S500. Chemical analysis for determination of ammonium ion (NH4+ content in the obtained samples was performed by the method of Kjeldahl. Calculations of lattice parameters, size of coherent scattering regions and the values of micro-deformations were carried out by TOPAS program. Main Results. Preparation processes of ultradisperse, homogeneous powder Sr1-хNdхF2+х (х= 0.003-0.2, with use of ammonium fluoride as the fluorinating agent taken over 114-120 % from stoichiometry, provides obtaining the firm solution Sr1-x-yNdx(NH4yF2+x-y of the cubic fluorite structure. It has been found out that the morphology and size of the resulting product depend on the quantity of

  6. Scientific Opinion on Dietary Reference Values for fluoride

    Directory of Open Access Journals (Sweden)

    EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA

    2013-08-01

    Full Text Available Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA derived Dietary Reference Values (DRVs for fluoride, which are provided as Adequate Intake (AI from all sources, including non-dietary sources. Fluoride is not an essential nutrient. Therefore, no Average Requirement for the performance of essential physiological functions can be defined. Nevertheless, the Panel considered that the setting of an AI is appropriate because of the beneficial effects of dietary fluoride on prevention of dental caries. The AI is based on epidemiological studies (performed before the 1970s showing an inverse relationship between the fluoride concentration of water and caries prevalence. As the basis for defining the AI, estimates of mean fluoride intakes of children via diet and drinking water with fluoride concentrations at which the caries preventive effect approached its maximum whilst the risk of dental fluorosis approached its minimum were chosen. Except for one confirmatory longitudinal study in US children, more recent studies were not taken into account as they did not provide information on total dietary fluoride intake, were potentially confounded by the use of fluoride-containing dental hygiene products, and did not permit a conclusion to be drawn on a dose-response relationship between fluoride intake and caries risk. The AI of fluoride from all sources (including non-dietary sources is 0.05 mg/kg body weight per day for both children and adults, including pregnant and lactating women. For pregnant and lactating women, the AI is based on the body weight before pregnancy and lactation. Reliable and representative data on the total fluoride intake of the European population are not available.

  7. Irradiation effects on microhardness of fluoridated and non-fluoridated bovine dentin

    International Nuclear Information System (INIS)

    The objective of this study was to evaluate the effects of irradiation on microhardness of dentin. Dentin blocks from the cervical region of bovine incisors were treated as follows: 1) no irradiation; 2) irradiation of specimens up to 60 Gy (2Gy/day, 5 days/week); 3) no irradiation, but fluoridation of specimens for 5 min/d; 4) irradiation of specimens and daily fluoridation. Knoop hardness number (KHN) of the control specimens was 62.63±14.75 (mean±SD). This was significantly different from the irradiated dentin samples (8.74±2.59 KHN). Hardness of the fluoridated dentin specimens was 11.19±1.95 KHN in the non-irradiated group and 10.03±2.75 KHN in the irradiated groups, respectively. Within the limitations of an in vitro study, it is concluded that dentin is severely affected by irradiation. This could be an explanation for the frequently observed side-effects of irradiation like loss of enamel, gap formation at the amelodentinal junction, and caries of the cervical region. Fluoridation with acidic gels decereases microhardness of dentin surface, and does not prevent softening due to radiation, when saliva is absent. (au)

  8. Synthesis and characterization of ruthenium fluorides and oxide fluorides with high oxidation states

    International Nuclear Information System (INIS)

    The synthesis of ruthenium fluorides and oxide fluorides with high oxidation states was attempted from dioxide RuO2 and tetroxide RuO4. Three fluorinating agents were used: fluorine, chlorine trifluoride and krypton difluoride. The reactions were achieved in anhydrous hydrogen fluoride at room temperature. Thus, the reaction of RuO4 with CIF3 enabled us to prepare chloryl hexafluororuthenate (V), CIO2+ RuF6-, a new compound well identified by vibrational spectroscopy (infra-red and Raman), the structure of which was determined. The reaction of KrF2 with RuO4 gave the oxide tetrafluoride RuOF4, the previously published syntheses and properties of which were not in agreement with each other. This compound was definitely characterized here by chemical analysis, infra-red spectroscopy and X-ray powder diffraction. The product of thermal decomposition (700C) of RuOF4 is presumably RuF4 since only oxygen is liberated during this decomposition. At last, the reaction of KrF2 with RuO2 probably leads to the formation of the new oxide fluoride RuO2F4. Indeed, no oxygen is given off during this reaction, the chemical analysis of the red-orange coloured solid residue is almost in agreement with the one proposed and its infra-red absorption spectrum indicates the presence of ruthenium-oxygen and ruthenium-terminal and bridging fluorine bonds

  9. CAN FLUORIDATION AFFECT LEAD (II) IN POTABLE WATER? HEXAFLUOROSILICATE AND FLUORIDE EQUILIBRIA IN AQUEOUS SOLUTION

    Science.gov (United States)

    Recent reports have attempted to show that fluoridating potable water is linked to increased levels of lead(II) in the blood. We examine these claims in light of the established science and critically evaluate their significance. The completeness of hexafluorosilicate hydrolysi...

  10. Effects of alternating periods of high- and low- fluoride ingestion on dairy cattle

    Energy Technology Data Exchange (ETDEWEB)

    Suttie, J.W.; Carlson, J.R.; Faltin, E.C.

    1972-01-01

    Two- and five-month old Holstein heifers were exposed to different intake patterns of dietary fluoride for 6 years. None of the fluoride treatments affected growth rate or reproduction. There was no consistent effect on milk production. Plasma fluoride concentrations closely followed current fluoride intake. Urinary fluoride concentrations varied with intake but remained elevated during low intake. Skeletal fluoride retention was directly related to total fluoride intake and not to pattern of intake. The degree of dental fluorosis was related to the amount of fluoride fed and to the plasma fluoride concentration at the time each incisor was developing. The most severe effects of fluoride ingestion were in high and low intake. These animals had severly worn molar teeth, extensive osteofluorosis, and they experienced periods of extreme lameness. Short periods of high fluoride intake balanced by periods of lower intake were more damaging to cattle than constant exposure to the same average yearly intake.

  11. The effects of argon in the bioenergetics of the hamster and the rat

    Science.gov (United States)

    Tempel, G. E.; Musacchia, X. J.

    1974-01-01

    Oxygen consumption was examined in hamsters and rats exposed to normoxic mixtures of argon at 1 atm. In fasted and nonfasted animals, no marked change in O2 utilization was detectable at 22 C. However, at 7 C a significant decrease in oxygen consumption was observed where the animals were exposed in argon. The data are interpreted in terms of the greater thermal conductivity of nitrogen. The study was prompted by conflicting reports on the metabolic effects of argon and helium.

  12. Computational investigation of the role of fluoride in Tamao oxidations

    DEFF Research Database (Denmark)

    Mader, Mary M.; Norrby, Per-Ola

    2002-01-01

    The Tamao oxidation of alkoxysilanes was investigated computationally to determine the role of fluoride. a key additive. in this reaction. A sequence of fluoride equilibria as well as possible transition states. mediated by basic and neutral peroxide, respectively, were examined, and a potential...

  13. Methods of controlling hydrogen fluoride pressure during chemical fabrication processes

    Science.gov (United States)

    Solovyov, Vyacheslav; Wiesmann, Harold

    2009-11-24

    The present invention is a method for producing a crystalline end-product. The method comprising exposing a fluoride-containing precursor to a hydrogen fluoride absorber under conditions suitable for the conversion of the precursor into the crystalline end-product.

  14. 7 CFR 305.8 - Sulfuryl fluoride treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Sulfuryl fluoride treatment schedules. 305.8 Section 305.8 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH... fluoride treatment schedules. Treatment schedule Pressure Temperature ( °F) Dosage rate(lb/1000 cubic...

  15. Fluoride uptake from restorative dental materials by human enamel

    International Nuclear Information System (INIS)

    The purpose of the study was to determine the uptake in vitro of fluoride from restorative materials by tooth enamel and whether prior etching of the enamel causes a change of uptake. The outermost layer of the labial surface of extracted canines was removed by grinding and the enamel was covered with five different fluoride-containing materials ; a silicate, a composite resin, an amalgam, a silicophosphate, and a polycarboxylate luting cement. The material was either removed immediately or after storing the tooth in distilled water. The fluoride content was determined using a sensitive physical method based on the 19F (p, αγ) 16O reaction. In addition, the fluoride content of enamel after etching for different periods of time and of etched enamel which had been in contact with silicate cement was determined. The mean fluoride content of uncovered interior enamel was 226 parts 106. All materials, except the composite, increased clearly the fluoride content of the underlying enamel. Etching of interior enamel also increased the fluoride values. No difference could be shown in fluoride uptake from silicate and composite resin between etched and unetched enamel. (author)

  16. KINETICS OF SORPTION OF FLUORIDE ON CALCINED MAGNESITE IN BATCH

    DEFF Research Database (Denmark)

    Singano, J. J.; Mashauri, D. A.; Mtalo, F. W.;

    1997-01-01

    A series of sorption of fluoride on calcined magnesite are obtained from thermostatic pH-chemostat and jar test experiments. The fluoride removal is observed not to start instantly, as normal, but after a lag time of up to ½ an hour of contact time. A model for sorption kinetics is developed, bas...

  17. Fluoride release by glass ionomer cements, compomer and giomer

    Directory of Open Access Journals (Sweden)

    Sayed Mostafa Mousavinasab

    2009-01-01

    Conclusion:Fuji IX, Fuji VII, Fuji IX Extra, and Fuji II LC released higher amounts of fluoride compared to Beautifil and Dyract Extra in this study. It seems that the extent of the glass ionomer matrix plays an important role in determining the fluoride releasing ability of glass ionomer cement materials.

  18. Fluoride Analysis. Training Module 5.200.2.77.

    Science.gov (United States)

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with fluoride analysis procedures. Included are objectives, an instructor guide, student handouts, and a list of reference material. This module considers the determination of fluoride in water supplies using the SPANDS and electrode…

  19. Obstacles to extending fluoridation in the United States.

    Science.gov (United States)

    Neenan, M E

    1996-09-01

    The purpose of this paper is two-fold: (1) to describe the current extent of water fluoridation in the United States; (2) to address the major obstacles to attaining 75 per cent fluoridation by the year 2000. While 62.1 per cent of the US population has access to fluoridated public water systems, more than 32 million people need to be added to the fluoridation census, primarily from the cities. The legal framework for implementing fluoridation is considered at the state level; a review of fluoridation actions at the local level is presented. The impact of forces affecting the extension of fluoridation in the United States is described: (1) demographic trends--urbanisation, race, ethnicity, language, immigration, age, education levels, housing, income and poverty levels; (2) external environmental forces/political climate; (3) media influence on public opinion and public policy; (4) voter apathy/lack of awareness of the benefits of fluoridation; (5) perceptions of risks vs. benefits; (6) lack of political campaign skills; and (7) legal issues.

  20. Mechanisms of action of fluoride for caries control

    NARCIS (Netherlands)

    M.A.R. Buzalaf; J.P. Pessan; H.M. Honório; J.M. ten Cate

    2011-01-01

    Fluoride was introduced into dentistry over 70 years ago, and it is now recognized as the main factor responsible for the dramatic decline in caries prevalence that has been observed worldwide. However, excessive fluoride intake during the period of tooth development can cause dental fluorosis. In o

  1. Poisoning by coal smoke containing arsenic and fluoride

    Energy Technology Data Exchange (ETDEWEB)

    An, D.; He, Y.G.; Hu, Q.X. [Guizhou Sanitary and Epidemiological Station, Guiyang (China)

    1997-02-01

    An investigation was made into a disease involving skin pigmentation, keratosis of the hands and feet, dental discoloration, and generalized bone and joint pain, stiffness and rigidity, in the village of Bazhi, Zhijin County, Ghizhou Province, People`s Republic of China. Measurements were made of the arsenic and fluoride levels of coal, water, air, food, urine and hair in Bazhi and a control village, Xinzhai, in which coal with a low arsenic content was used. Up to 188 people, including children, in Bazhi and 752 in Xinzhai, were examined for the presence of chronic arsenium, skeletal fluorosis, dental fluorosis and electrocardiogram abnormalities. The coal in Bazhi was found to contain high levels of arsenic and fluoride resulting, after burning in homes without an adequate chimney systems, in pollution of air and food with arsenic and fluoride. The coal in Xinzhai did not cause arsenic pollution but did produce a higher level of fluoride pollution. It was concluded that the endemic disease in Bazhi was caused by pollution by coal smoke containing arsenic and fluoride. It is suggested that arsenic may act synergistically with fluoride so that a lower level of fluoride may produce fluoride toxicity with dental and skeletal fluorosis.

  2. Fluoride inhibits the response of bone cells to mechanical loading

    NARCIS (Netherlands)

    H.M.E. Willems; E.G.H.M. van den Heuvel; S. Castelein; J. Keverling Buisman; A.L.J.J. Bronckers; A.D. Bakker; J. Klein-Nulend

    2011-01-01

    The response of bone cells to mechanical loading is mediated by the cytoskeleton. Since the bone anabolic agent fluoride disrupts the cytoskeleton, we investigated whether fluoride affects the response of bone cells to mechanical loading, and whether this is cytoskeleton mediated. The mechano-respon

  3. Argon Laser Photoablation for Treating Benign Pigmented Conjunctival Nevi

    Science.gov (United States)

    Alsharif, Abdulrahman M.; Al-Gehedan, Saeed M.; Alasbali, Tariq; Alkuraya, Hisham S.; Lotfy, Nancy M.; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the outcomes of argon laser photoablation of benign conjunctival pigmented nevi with different clinical presentations. Patients and Methods: This interventional case series was conducted between July 2014 and January 2015. Patients presenting with benign conjunctival nevi were included. Data were collected on the clinical features at presentation, argon laser photoablation, and follow-up at 8 and 24 weeks. Postoperative photography allowed recording of the success of each case and the overall success rate. Complete removal of conjunctival pigments was considered an absolute success. Partial pigmentation requiring repeat laser treatment was considered a qualified success. Results: There were 14 eyes (four right eyes and ten left eyes) with benign pigmented conjunctival nevi. There were three males and eight females in the study sample. The median age was 36 (25% percentile: 26 years). Three patients had bilateral lesions. The nevi were located temporally in nine eyes, nasally in three eyes, and on the inferior bulbar conjunctiva in two eyes. The mean horizontal and vertical diameters of nevi were 5 ± 2 mm and 4 ± 2.7 mm, respectively. The mean follow-up period was 5 months. Following laser treatment, no eyes had subconjunctival hemorrhage, infection, scarring, neovascularization, recurrence, or corneal damage. The absolute success rate of laser ablation was 79%. Three eyes with elevated nevi had one to three sessions of laser ablation resulting in a qualified success rate of 100%. Conclusions: Argon laser ablation was a safe and effective treatment for the treatment of selective benign pigmented conjunctival nevi in Arab patients. PMID:27555708

  4. The status of community water fluoridation in the United States.

    Science.gov (United States)

    Easley, M W

    1990-01-01

    Community water fluoridation has served the American public extremely well as the cornerstone of dental caries prevention activities for 45 years. The dental and general health benefits associated with the ingestion of water-borne fluorides have been well known by researchers for an even longer period. Continued research has repeatedly confirmed the safety, effectiveness, and efficiency of community water fluoridation in preventing dental caries for Americans regardless of age, race, ethnicity, religion, educational status, or socioeconomic level. Despite the obvious benefits associated with this proven public health measure, slow progress has been made toward achieving the 1990 national fluoridation objectives as listed in "Promoting Health/Preventing Disease: Objectives for the Nation." This paper documents the lagging pace of community fluoridation by reviewing and analyzing data reported in "Fluoridation Census, 1985," a document published in late 1988 by the Public Health Service's Centers for Disease Control. Failure to attain the 1990 objectives is attributable to a combination of circumstances, including their low priority within many local, State, and Federal health agencies, inadequate funding at all levels of government, lack of a coordinated and focused national fluoridation effort, failure of most States to require fluoridation, lack of Federal legislation mandating fluoridation, general apathy of most health professional organizations toward fluoridation, misconceptions by the public about effectiveness and safety and, finally, unrelenting opposition by a highly vocal minority of the lay public. In addition, fluoridation successes have not been consistent among States, with wide variation in accomplishments documented in the reported data.While fluoridation still is one of the most cost effective public health measures available to local,State, and Federal public health agencies, it remains significantly underused nearly a half century after its

  5. LUMINESCENCE IN POTENTIAL FLUORIDE GLASS LASERS

    OpenAIRE

    Jørgensen, C.

    1987-01-01

    Fluoride glasses of the zirconium barium lanthanide type (invented Rennes, 1975) and lead gallium zinc (or manganese) type (invented Le Mans, 1979) show luminescence of lanthanide J-Levels situated at least 2000 cm-1 above the closest lower level (this limit is a few times larger in most other materials). Not only is the non-radiative de-excitation as weak as incrystalline LaF3 (studied by Weber) but energy transfer between neodymium and ytterbium (III), or from manganese (II), and to some ex...

  6. Electrorecovery of tantalum in molten fluorides

    International Nuclear Information System (INIS)

    Considering the privileged situation of Brazil as a productor of tantaliferous minerals, the authors have in view the development of a technology for production of metallic tantalum via molten salts electrolysis; this has the advantage of improving the aggregate value of exportation products, additionally to tantalum oxide and tantalum concentrates. Having in view the preliminary determintion of better conditions of temperature, electrolyte composition and current density for this process, electrolysis were conducted with a solvent composed of an eutetic mixture of lithium, sodium and potassium fluoride for dipotassium fluotantalate and occasionally for tantalum oxide. Current efficiencies as high as 83% were obtained in favoured conditions. (author)

  7. Fluoride microresonators for mid-IR applications

    CERN Document Server

    Grudinin, Ivan S; Yu, Nan

    2016-01-01

    We study crystalline fluoride microresonators for mid-infrared applications. Whispering gallery mode resonators were fabricated with BaF$_2$, CaF$_2$ and MgF$_2$ crystals. The quality factors were measured at wavelengths of 1.56 {\\mu}m and 4.58 {\\mu}m. The impacts of fabrication technique, impurities, multiphonon absorption and surface water are investigated. It is found that MgF2 resonators have room temperature Q factor of $8.3\\times 10^6$ at wavelength of 4.58 {\\mu}m, limited by multiphonon absorption.

  8. Caries prevention with fluoride toothpaste in children: an update

    DEFF Research Database (Denmark)

    Twetman, S

    2009-01-01

    AIM: The aim was to examine recent literature and review the caries-preventive effect of fluoride toothpaste in children. METHODS: Based on three comprehensive systematic reviews published in 2003, a broad search of the PubMed and Cochrane library databases was conducted for papers published 2002......-2008 using "fluoride toothpaste", "fluoride dentifrice" and "fluoride dental cream" as index terms. Relevant publications were identified after assessment of their abstracts. Papers were selected if they reported a prospective controlled design with caries data reported at baseline and at the end...... of the study. The targeted papers were critically assessed concerning design, methodology and performance according to a pre-determined checklist. RESULTS: The initial search revealed 179 papers of which 15 met the inclusion criteria. There was strong evidence that daily use of fluoride toothpaste has...

  9. Ion chromatography detection of fluoride in calcium carbonate.

    Science.gov (United States)

    Lefler, Jamie E; Ivey, Michelle M

    2011-09-01

    Fluoride in aquatic systems is increasing due to anthropogenic pollution, but little is known about how this fluoride affects organisms that live in and around aquatic habitats. Fluoride can bioaccumulate in structures comprised of calcium carbonate, such as shells and skeletons of both freshwater and saltwater species as diverse as snails, corals, and coccolithophorid algae. In this article, ion chromatography (IC) techniques are developed to detect and quantify fluoride in a matrix of calcium carbonate. Solid samples are dissolved in hydrochloric acid, pretreated to remove the majority of the chloride ions, and then analyzed using IC. With these methods, the 3σ limit of detection is 0.2 mg of fluoride/kg of calcium carbonate. PMID:21859530

  10. Fluoride use in Controlling Dental Caries and Fluorosis

    Directory of Open Access Journals (Sweden)

    Gaurav Solanki

    2012-07-01

    Full Text Available Policy were introduced to control fluoride exposure and to reduce the prevalence of fluorosis. The study aimed of describing the prevalence, severity and risk factors for fluorosis, and to describe the trend of fluorosis among Indian children. The study also aimed of exploring the effect of the change in fluoride exposure on dental fluorosis and caries. Establishing an appropriate use of fluoride toothpaste could be successful in reducing fluorosis without a significant increase in caries experience. The use of fluorides for oral health has always involved a balance between the protective benefit against dental caries and the risk of developing fluorosis. The link between fluoride and dental health was established to determining the causes of dental fluorosis or enamel mottling. Fluorosis in Indian children was highly prevalent in the early 1990s.

  11. Assessment of groundwater quality with respect to fluoride.

    Science.gov (United States)

    Salve, P R; Maurya, A; Kumbhare, P S; Ramteke, D S; Wate, S R

    2008-09-01

    The study was conducted in the summer season (April-May 2007). The fluoride concentration along with physico-chemical parameters in ground water samples was determined in various villages of Kadi tehsil at Mehsana district of Gujarat state (India), since in most of the villages it is the only source of drinking water. The fluoride concentrations in these villages varied from 0.94 to 2.81 mg/L (1.37+/-0.56) with highest fluoride level at Visalpur (2.08 mg/L) and lowest at Adaraj (0.91 mg/L). There was found a positive correlation of pH with fluoride and a negative relationship of fluoride with bicarbonate which is generally observed in deep ground water.

  12. The abundances of neon, sulfur, and argon in planetary nebulae

    Science.gov (United States)

    Beck, S. C.; Lacy, J. H.; Townes, C. H.; Aller, L. H.; Geballe, T. R.; Baas, F.

    1981-01-01

    New infrared observations of Ne II, Ar III, and S IV are used in optical observations of other ionization states of the considered elements to evaluate the abundances of neon, argon, and sulfur in 18 planetary nebulae. Attention is also given to one or more of the infrared lines in 18 other nebulae. It is pointed out that S IV was detected in approximately 90% of the observed objects, while Ar III was found in about 80%, and Ne II in roughly one-third. It is noted that optical observations typically include only a limited region of the nebula, while the infrared measurements frequently involve integration over the entire nebular image.

  13. Ionization coefficients for argon in a micro-discharge

    International Nuclear Information System (INIS)

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges. (paper)

  14. Kinetic modeling of the Townsend breakdown in argon

    Science.gov (United States)

    Macheret, S. O.; Shneider, M. N.

    2013-10-01

    Kinetic modeling of the Townsend breakdown in argon was performed in the "forward-back" approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  15. Ionization coefficients for argon in a micro-discharge

    Science.gov (United States)

    Kuschel, Thomas; Stefanović, Ilija; Malović, Gordana; Marić, Dragana; Petrović, Zoran Lj

    2013-08-01

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges.

  16. Diffusion coefficient of metal vapours into rare gases. Mercury - argon

    International Nuclear Information System (INIS)

    The source information is present as well as the results of analysis and integration of data on mutual diffusion coefficient (MDC) of mercury - argon mixture at Hg concentration → 0 in 300-2500 K temperature range. Reference data on MDC for metal - inert gas binary mixtures obtained on the base of complex analysis of various information, as it exemplified by Hg-Ar pair, can be used as a part of metrological support at calibration of devices for determination MDC of gas - metal vapors

  17. Electron drift velocity in argon-methane mixture

    International Nuclear Information System (INIS)

    Described are the results of a series of measurements of electron drift velocity taken with samples of chemically pure grade gas mixture of Ar-10% CH4 (N2222O<2 ppm). The measured drift velocity is plotted as a function of the ratio of electric field to pressure in the range from 0.05 to 0.8 V/cmxtorr. The measurements are reproducible only to within 4%. The results of numerical calculations employing the well-established argon elastic and methane elastic and inelastic cross sections are also included. The disagreement from the present experimental results, and from those obtained elsewhere, is rather puzzling

  18. High intensity, argon ion laser-jet photochemistry

    Science.gov (United States)

    Wilson, R. Marshall; Schnapp, Karlyn A.; Hannemann, Klaus; Ho, Douglas M.; Memarian, Hamid R.; Azadnia, Ardeshir; Pinhas, Allan R.; Figley, Timothy M.

    A new technique for the study of high intensity solution photochemistry has been developed. With this laser-jet technique, a high velocity microjet is irradiated with the focussed output of an argon ion laser. Under these extremely high intensity conditions, photochemically generated transient species with suitable absorption properties are excited further and produce relatively large amounts of photoproducts which are not observed under low intensity conditions. The application of this laser-jet technique in the study of the photochemistry of radicals, biradicals, photoenols and the higher excited states of carbonyl and polycyclic aromatic compounds is described.

  19. Optical fiber read-out for liquid argon scintillation light

    CERN Document Server

    Csáthy, J Janicskó; Kratz, J; Schönert, S; Wiesinger, Ch

    2016-01-01

    In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high purity germanium (HPGe) detectors operated directly in liquid Argon (LAr). Background suppression efficiencies for different radioactive sources were measured in a test cryostat with about 800 kg LAr. This work was part of the R\\&D effort for the GERDA experiment.

  20. Study of a novel electromagnetic liquid argon calorimeter TGT

    International Nuclear Information System (INIS)

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a test beam exposure. 15 refs., 16 figs., 2 tabs

  1. Activation of copper by nitrogen and argon beams

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkova, Vera [IAP, Goethe-University, Frankfurt am Main (Germany); GSI Darmstadt (Germany); Mustafin, Edil; Strasik, Ivan [GSI Darmstadt (Germany); Belousov, Anton [TU Darmstadt (Germany); Latysheva, Ludmila; Sobolevsky, Nikolai [INR RAS, Moscow (Russian Federation); Ratzinger, Ulrich [IAP, Goethe-University, Frankfurt am Main (Germany)

    2012-07-01

    Monte Carlo transport codes are widely used for various purposes in nuclear physics, radiation protection, medical applications, accelerator design etc. Code verification by experiments is needed to be sure that the codes give accurate results. New data on the activation of copper by a nitrogen beam of 500 MeV/u is presented and compared with FLUKA and SHIELD simulation results. The activation of copper by a nitrogen beam is compared to activation by an argon beam and respective simulations. This gives a chance to see the accuracy of the codes at different projectile masses. Correspondences and discrepancies of calculations and experiments are discussed.

  2. Study of a Novel Concept for a Liquid Argon Calorimeter \

    CERN Multimedia

    2002-01-01

    % RD33 \\\\ \\\\ The development of a fast, highly granular and compact electromagnetic liquid argon calorimeter prototype is proposed as a generic R\\&D project for a novel concept of calorimetry in proton-proton and electron-positron collider detectors: the $^{\\prime$Thin Gap Turbine$^{\\prime}$ (TGT). The TGT calorimeter has a modular construction, is flexible in its longitudinal and transverse granularity, and offers a uniform energy response and resolution, independent of the production angle of incident particles. An important aspect of the project is the development of fast, radiation-hard front-end electronics which is operating in the cold.

  3. Activation of aluminum by argon: Experimental study and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkova, V., E-mail: v.chetvertkova@gsi.de [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); J. W. Goethe-University Frankfurt am Main, IAP, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Strasik, I. [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); J. W. Goethe-University Frankfurt am Main, IAP, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Belousov, A. [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); Iwase, H. [High Energy Accelerator Research Organization, KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Mokhov, N. [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States); Mustafin, E. [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); Latysheva, L. [Institute for Nuclear Research RAS, 117312 Moscow (Russian Federation); Pavlovic, M. [FEI STU, Ilkovicova 3, 812 19 Bratislava (Slovakia); Ratzinger, U. [J. W. Goethe-University Frankfurt am Main, IAP, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Sobolevsky, N. [Institute for Nuclear Research RAS, 117312 Moscow (Russian Federation)

    2011-06-15

    The paper presents the results of irradiation of aluminum targets by 430 and 500 MeV/u argon beams. Gamma-spectra were measured after the end of the irradiation in order to identify the induced nuclides as well as to determine their residual activity depth-profiles. The results of this experiment are compared with Monte Carlo simulations by FLUKA, GEANT4, MARS, PHITS and SHIELD-A codes. In case of a thin target, the agreement between the experiment and simulations is satisfactory, while in case of a thick target, some discrepancies are observed.

  4. Laser-induced vibrational dynamics of ozone in solid argon

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; Amstrup, B.; Henriksen, Niels Engholm

    1997-01-01

    We consider the vibrational dynamics, induced by an intense infrared laser pulse, in an ozone molecule with isotopic substitution, that is, (OOO)-O-16-O-16-O-18 and compare the dynamics in the gas phase and in solid ar on. not perturbed by argon on a time-scale of a few picoseconds and selective...... bond-breaking in the molecule should be possible following the same laser control scheme as suggested in the gas phase. (C) 1997 Elsevier Science B.V....

  5. Electron transport in argon in crossed electric and magnetic fields

    Science.gov (United States)

    Ness; Makabe

    2000-09-01

    An investigation of electron transport in argon in the presence of crossed electric and magnetic fields is carried out over a wide range of values of electric and magnetic field strengths. Values of mean energy, ionization rate, drift velocity, and diffusion tensor are reported here. Two unexpected phenomena arise; for certain values of electric and magnetic field we find regions where the swarm mean energy decreases with increasing electric fields for a fixed magnetic field and regions where swarm mean energy increases with increasing magnetic field for a fixed electric field. PMID:11088933

  6. Surface Modification of Polyvinylidene Fluoride (PVDF) Membranes by Low-Temperature Plasma with Grafting Styrene

    Science.gov (United States)

    Chen, Jian; Li, Jiding; Chen, Cuixian

    2009-02-01

    In order to control the surface pore sizes of polyvinylidene fluoride membranes and their distribution, low temperature plasma-induced grafting modifications of PVDF were studied to prepare hydrophobe membranes. By argon (Ar) treating and subsequent grafting reaction, a hydrophobe monomer, styrene, was introduced into the PVDF membrane. Fourier transform infrared attenuated total reflection (FTIR-ATR) was utilized to characterize the chemical and physical changes in the Ar plasma modified membrane. The surface modifications of PVDF membranes were investigated by using scanning electron microscopy (SEM), atomic force microscopy (AFM) and differential scanning calorimeter (DSC). The water permeability and the solute rejection were measured by PVDF membrane modified in different graft conditions. Results demonstrated that the pores in the modified membranes get smaller and the distribution of pores gets narrowed with the increase in grafting reaction duration. Longer graft time caused the water flux of PVDF membrane to decrease from 578 kg/(m2·h) to 23 kg/(m2·h) and the solute rejection to increase from 73% to 92%.

  7. Surface Modification of Polyvinylidene Fluoride(PVDF)Membranes by Low-Temperature Plasma with Grafting Styrene

    Institute of Scientific and Technical Information of China (English)

    CHEN Jian; LI Jiding; CHEN Cuixian

    2009-01-01

    In order to control the surface pore sizes of polyvinylidene fluoride membranes and their distribution.low temperature plasma-induced grafting modifications of PVDF were studied to prepare hydrophobe membranes.By argon(Ar)treating and subsequent grafting reaction,a hydrophobe monomer,styrene,was introduced into the PVDF membrane.Fourier transform infrared attenuated total reflection (FTIR-ATR) was utilized to characterize the chemical and Physical changes in the Ar plasma modified membrane.The surface modifications of PVDF membranes were investigated by using scanning electron microscopy(SEM),atomic force microscopy(AFM) and differential scanning calorimeter(DSC).The water permeability and the solute rejection were measured by PVDF membrane modified in different graft conditions.Results demonstrated that he pores in the modified membranes get smaller and the distribution of pores gets narrowed with the increase in grafting reaction duration.Longer graft time caused the water flux of PVDF membrane to decrease from 578 kg/(m2·h)to 23 kg/(m2·h)and the solute rejection to increase from 73%to 92%.

  8. Milk fluoridation for the prevention of dental caries

    Directory of Open Access Journals (Sweden)

    Jolán Bánóczy

    2013-11-01

    Full Text Available The aim of this review is to give an overview of 55 years experience of milk fluoridation and draw conclusions about the applicability of the method. Fluoridated milk was first investigated in the early 1950s, almost simultaneously in Switzerland, the USA and Japan. Stimulated by the favourable results obtained from these early studies, the establishment of The Borrow Dental Milk Foundation (subsequently The Borrow Foundation in England gave an excellent opportunity for further research, both clinical and non-clinical, and a productive collaboration with the World Health Organization which began in the early 1980s. Numerous peer-reviewed publications in international journals showed clearly the bioavailability of fluoride in various types of milk. Clinical trials were initiated in the 1980s – some of these can be classed as randomised controlled trials, while most of the clinical studies were community preventive programmes. Conclusion. These evaluations showed clearly that the optimal daily intake of fluoride in milk is effective in preventing dental caries. The amount of fluoride added to milk depends on background fluoride exposure and age of the children: commonly in the range 0.5 to 1.0 mg per day. An advantage of the method is that a precise amount of fluoride can be delivered under controlled conditions. The cost of milk fluoridation programmes is low, about € 2 to 3 per child per year. Fluoridation of milk can be recommended as a caries preventive measure where the fluoride concentration in drinking water is suboptimal, caries experience in children is significant, and there is an existing school milk programme.

  9. Caries prevention through the fluoridation of milk. A review.

    Science.gov (United States)

    Bánóczy, Jolán; Rugg-Gunn, Andrew J

    2007-10-01

    The aim of this review is to give an overview of 50 years experience of milk fluoridation and draw conclusions about the applicability of the method. Fluoridated milk was first investigated in the early 1950s, almost simultaneously in Switzerland, the USA and Japan. Stimulated by the favourable results obtained from these early studies, the establishment of The Borrow Dental Milk Foundation (subsequently The Borrow Foundation) in England gave an excellent opportunity for further research, both clinical and non-clinical, and a productive collaboration with the World Health Organization from the early 1980s onwards. Numerous peer-reviewed publications in international journals showed clearly the bioavailability of fluoride in milk, and increased concentrations of fluoride in saliva, dental plaque, dental enamel and dentine, and urine, after consumption of fluoridated milk. Clinical trials were initiated in the 1980s--some of these can be classed as randomised controlled trials, while most of the clinical studies were community preventive programs. These evaluations showed clearly that the optimal daily intake of fluoride in milk is effective in preventing dental caries. At present, milk fluoridation programs are running continuously in about ten countries of the world. Fluoridation of milk can be recommended as a caries preventive measure where the fluoride concentration in drinking water is suboptimal, caries experience in children is significant, and there is an existing school milk program. The program should aim to provide fluoridated milk for at least 200 days per year and should commence before the children are 4 years of age. PMID:18078140

  10. Fluoride caused thyroid endocrine disruption in male zebrafish (Danio rerio).

    Science.gov (United States)

    Jianjie, Chen; Wenjuan, Xue; Jinling, Cao; Jie, Song; Ruhui, Jia; Meiyan, Li

    2016-02-01

    Excessive fluoride in natural water ecosystem has the potential to detrimentally affect thyroid endocrine system, but little is known of such effects or underlying mechanisms in fish. In the present study, we evaluated the effects of fluoride on growth performance, thyroid histopathology, thyroid hormone levels, and gene expressions in the HPT axis in male zebrafish (Danio rerio) exposed to different determined concentrations of 0.1, 0.9, 2.0 and 4.1 M of fluoride to investigate the effects of fluoride on thyroid endocrine system and the potential toxic mechanisms caused by fluoride. The results indicated that the growth of the male zebrafish used in the experiments was significantly inhibited, the thyroid microtrastructure was changed, and the levels of T3 and T4 were disturbed in fluoride-exposed male fish. In addition, the expressional profiles of genes in HPT axis displayed alteration. The expressions of all studied genes were significantly increased in all fluoride-exposed male fish after exposure for 45 days. The transcriptional levels of corticotrophin-releasing hormone (CRH), thyroid-stimulating hormone (TSH), thyroglobulin (TG), sodium iodide symporter (NIS), iodothyronine I (DIO1), and thyroid hormone receptor alpha (TRα) were also elevated in all fluoride-exposed male fish after 90 days of exposure, while the inconsistent expressions were found in the mRNA of iodothyronineⅡ (DIO2), UDP glucuronosyltransferase 1 family a, b (UGT1ab), transthyretin (TTR), and thyroid hormone receptor beta (TRβ). These results demonstrated that fluoride could notably inhibit the growth of zebrafish, and significantly affect thyroid endocrine system by changing the microtrastructure of thyroid, altering thyroid hormone levels and endocrine-related gene expressions in male zebrafish. All above indicated that fluoride could pose a great threat to thyroid endocrine system, thus detrimentally affected the normal function of thyroid of male zebrafish.

  11. 76 FR 37129 - Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride F-18) Injection, 10 to 200 Millicuries...

    Science.gov (United States)

    2011-06-24

    ... Product List'' section of the Orange Book. In previous instances (see, e.g., 72 FR 9763, March 5, 2007; 61 FR 25497, May 21, 1996), the Agency has determined that, for purposes of Sec. Sec. 314.161 and 314... HUMAN SERVICES Food and Drug Administration Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride...

  12. Luminescence in potential fluoride glass lasers

    International Nuclear Information System (INIS)

    Fluoride glasses of the zirconium barium lanthanide type (invented Rennes, 1975) and lead gallium zinc (or manganese) type (invented Le Mans, 1979) show luminescence of lanthanide J-Levels situated at least 2000 cm-1 above the closest lower level (this limit is a few times larger in most other materials). Not only is the non-radiative de-excitation as weaK as in crystalline LaF3 (studied by Weber) but energy transfer between neodymium and ytterbium(III), or from manganese(II), and to some extent from chromium(III), to luminescent J-levels of neodymium(III), erbium(III) and thullium(III) is highly efficient even at low concentrations. One advantage for laser applications is that the lowest quartet state of manganese(II) has a life-time 10 to 15 milliseconds (like in many phosphate glasses and crystalline compounds) allowing energy transfer, extending by huge factors the average life-time of the emitting J-levels. Though the tera-watt lasers (Livermore, California, 1978) inducing deuterium-tritium fusion are silicate glass containing neodymium(III), fluoride glasses should be preferable for many purposes. The evaluation of laser parameters from small-scale experimentation is feasible

  13. Polyvinylidene fluoride - a polymer as transducer material

    International Nuclear Information System (INIS)

    Polyvinylidene fluoride or PVDF is a flexible, thin piezo film and long chain semicrystalline polymer containing repeated of CH/sub 2/ - CH/sub 2/. In order to obtain desired piezoelectric properties PVDF is poled by subjecting it to high electric field. In poled PVDF piezoelectric constants have different values for each axis and one constant per axis. PVDF polymer exhibits generator and motor action. Usually 1000 A /sup o/ thick vacuum-deposited aluminum electrodes are formed on both sides of the sheet. Polymer material of PVDF can be used as a sensing element with temperature range of -40 /sup 0/ C to 100 /sup 0/C and a frequency range of 10/sup -3/ to 10/sup -9/ Hz. This paper includes as experimental observation of exciting aluminium open-ended tube at its resonance using PVDF transducer and maintained in this condition using phase lock loop or PLL. The tube is free to resonate when 9-micrometer thin polyvinylidene fluoride transducer is energized. It is observed that a film of such material can easily be used to produced the requisite vibrations in the tube. (author)

  14. Lanthanum fluoride nanoparticles for radiosensitization of tumors

    Science.gov (United States)

    Kudinov, Konstantin; Bekah, Devesh; Cooper, Daniel; Shastry, Sathvik; Hill, Colin; Bradforth, Stephen; Nadeau, Jay

    2016-03-01

    Dense inorganic nanoparticles have recently been identified as promising radiosensitizers. In addition to dose enhancement through increased attenuation of ionizing radiation relative to biological tissue, scintillating nanoparticles can transfer energy to coupled photosensitizers to amplify production of reactive oxygen species, as well as provide UVvisible emission for optical imaging. Lanthanum fluoride is a transparent material that is easily prepared as nanocrystals, and which can provide radioluminescence at a number of wavelengths through simple substitution of lanthanum ions with other luminescent lanthanides. We have prepared lanthanum fluoride nanoparticles doped with cerium, terbium, or both, that have good spectral overlap with chlorine6 or Rose Bengal photosensitizer molecules. We have also developed a strategy for stable conjugation of the photosensitizers to the nanoparticle surface, allowing for high energy transfer efficiencies on a per molecule basis. Additionally, we have succeeded in making our conjugates colloidally stable under physiological conditions. Here we present our latest results, using nanoparticles and nanoparticle-photosensitizer conjugates to demonstrate radiation dose enhancement in B16 melanoma cells. The effects of nanoparticle treatment prior to 250 kVp x-ray irradiation were investigated through clonogenic survival assays and cell cycle analysis. Using a custom apparatus, we have also observed scintillation of the nanoparticles and conjugates under the same conditions that the cell samples are irradiated.

  15. LArIAT: Liquid Argon In A Testbeam

    CERN Document Server

    Cavanna, F; Raaf, J; Rebel, B

    2014-01-01

    Liquid Argon Time Projection Chambers (LArTPCs) are ideal detectors for precision neutrino physics. These detectors, when located deep underground, can also be used for measurements of proton decay, and astrophysical neutrinos. The technology must be completely developed, up to very large mass scales, and fully mastered to construct and operate these detectors for this physics program. As part of an integrated plan of developing these detectors, accurate measurements in LArTPC of known particle species in the relevant energy ranges are now deemed as necessary. The LArIAT program aims to directly achieve these goals by deploying LArTPC detectors in a dedicated calibration test beam line at Fermilab. The set of measurements envisaged here are significant for both the short-baseline (SBN) and long-baseline (LBN) neutrino oscillation programs in the US, starting with MicroBooNE in the near term and with the adjoint near and far liquid argon detectors in the Booster beam line at Fermilab envisioned in the mid-term...

  16. A liquid argon scintillation veto for the GERDA experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10-3 cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  17. A liquid argon scintillation veto for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10{sup -3} cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  18. Some transport properties in plasmas containing argon and fluorine

    Directory of Open Access Journals (Sweden)

    Novaković R.N.V.

    2003-01-01

    Full Text Available In this paper some results of numerical evaluation of transport coefficients in plasmas in the mixtures of argon and fluorine are presented. These transport characteristics are given in the function of the temperature for low pressures ranging from 0,1 kPa to 1,0 kPa and for low temperatures between 500 K and 5 000 K in argon plasmas with 20% and 30% of the fluorine added. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE is attained in it. The equilibrium plasma composition, necessary for the evaluations, was determined on the ground of the Saha equations for ionization processes and the law of mass action for the thermal dissociation of F2, combined with the charge conservation relation and the assumption that the pressure remained constant in the course of temperature variations. The ionization energy lowering, required in conjunction with the Saha equations, was obtained with the aid of a modified expression for the plasma Debye radius proposed previously. A previously derived expression for the modified Debye radius, offering the possibility to treat the plasmas considered as weakly non-ideal in the whole temperature range, is used. The cut-off at the Landau length rather than of the smallest of ionic radii is introduced. This alteration in the evaluation procedure brings different considerable changes in the final numerical results for the all relevant quantities.

  19. Compilation of electron collision excitation cross sections for neutro argon

    International Nuclear Information System (INIS)

    The present work presents a compilation and critical analysis of the available data on electron collision excitation cross sections for neutral Argon levels. This study includes: 1.- A detailed description in intermediate coupling for all the levels belonging the 20 configurations 3p''5 ns(n=4 to 12), np(n=4 to 8) and nd(n=3 to 8) of neutral Argon. 2.- Calculation of the electron collision excitation cross sections in Born and Born-Oppenheimer-Ochkur approximations for all the levels in the 14 configurations 3p''5 ns(n=4 to 7), np(n=4 to 7) and nd(n=3 to 8). 3.- Comparison and discussion of the compiled data. These are the experimental and theoretical values available from the literature, and those from this work. 4.- Analysis of the regularities and systematic behaviors in order to determine which values can be considered more reliable. It is show that the concept of one electron cross section results quite useful for this purpose. In some cases it has been possible to obtain in this way approximate analytical expressions interpolating the experimental data. 5.- All the experimental and theoretical values studied are graphically presented and compared. 6.- The last part of the work includes a listing of several general purpose programs for Atomic Physics calculations developed for this work. (Author)

  20. Elastic properties of liquid and solid argon in nanopores.

    Science.gov (United States)

    Schappert, Klaus; Pelster, Rolf

    2013-10-16

    We have measured sorption isotherms and determined the intrinsic longitudinal elastic modulus β(Ar,ads) of nanoconfined material via ultrasonic measurements combined with a special effective medium analysis. In the liquid regime the adsorbate only contributes to the measured effective properties when the pores are completely filled and the modulus is bulklike. At partial fillings its contribution is cancelled out by the high compressibility of the vapour phase. In contrast, at lower temperatures frozen argon as well as underlying liquid surface layers cause a linear increase of the effective longitudinal modulus upon filling. During sorption the contribution of the liquid surface layers near the pore wall β(Ar,surf) increases with the thickness of the solid layers reaching the bulk value β(Ar,liquid) only in the limit of complete pore filling. We interpret this effect as due to the gradual stiffening of the solid argon membrane. The measurements and their analysis show that longitudinal ultrasonic waves are well suited to the study of the elastic properties and liquid-solid phase transitions in porous systems. This method should also help to detect the influence of nanoconfinement on elastic properties in further research. PMID:24057946

  1. 21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for...

  2. Local effects of ECRH on argon transport at ASDEX upgrade

    International Nuclear Information System (INIS)

    Future deuterium-tritium magnetically confined fusion power plants will most probably rely an high-Z Plasma Facing Components (PFCs) such as tungsten. This choice is determined by the necessity of low erosion of the first wall materials (to guarantee a long lifetime of the wall components) and by the need to avoid the too high tritium wall retention of typical carbon based PFCs. The experience gathered at the ASDEX Upgrade (AUG) tokamak has demonstrated the possibility of reliable and high performance plasma operation with a full tungsten-coated first wall. The observed accumulation of tungsten which can lead to excessive radiation losses is mitigated with the use of Electron Cyclotron Resonance Heating (ECRH). Although this impurity control method is routinely performed at AUG, the underlying physics principles are still not clear. This thesis aims an providing further knowledge an the effects of ECRH an the transport of impurities inside the core plasma. The transport of argon has been therefore investigated in-depth in purely ECR heated L-mode (low-confinement) discharges. Studies an impurity transport in centrally ECR heated nitrogen-seeded H-mode (high-confinement) discharges have also been performed. To this scope, a new crystal X-ray spectrometer of the Johann type has been installed an AUG for argon concentration and ion temperature measurements. New methods for the experimental determination of the total argon density through the integrated use of this diagnostic and of the Soft X-Ray (SXR) diode arrays have been developed. This gives the possibility of evaluating the full profiles of the argon transport coefficients from the linear flux-gradient dependency of local argon density. In comparison to classical χ2-minimization methods, the approach proposed here delivers transport coefficients intrinsically independent of the modelling of periodic relaxation mechanisms such as those Lied to sawtooth MHD (Magneto-Hydro-Dynamic) activity. Moreover, the good

  3. High Fluoride Dentifrices for Elderly and Vulnerable Adults

    DEFF Research Database (Denmark)

    Ekstrand, Kim Rud

    2016-01-01

    The primary aim of this work is to present the available evidence that toothpastes containing >1,500 ppm fluoride (2,500-2,800 and 5,000 ppm F) provide an additional caries preventive effect on root caries lesions in elderly patients compared to traditional dentifrices (1,000-1,450 ppm F). The se......The primary aim of this work is to present the available evidence that toothpastes containing >1,500 ppm fluoride (2,500-2,800 and 5,000 ppm F) provide an additional caries preventive effect on root caries lesions in elderly patients compared to traditional dentifrices (1,000-1,450 ppm F......). The secondary aim of this paper is to discuss why high fluoride dentifrices in general should perform better than traditional F-containing toothpaste. When examining the few studies that have considered the preventive benefits of high fluoride products on root caries the relative risk appears to be around 0.......5, and the risk can thus be halved by exchanging traditional F-containing toothpaste for toothpaste containing 5,000 ppm F. There is reasonable evidence that high fluoride dentifrices significantly increase the fluoride concentration in saliva during the day and the fluoride concentration in plaque compared...

  4. The effective use of fluorides in public health

    DEFF Research Database (Denmark)

    Jones, Sheila; Burt, Brian A; Petersen, Poul Erik;

    2005-01-01

    Dental caries remain a public health problem for many developing countries and for underprivileged populations in developed countries. This paper outlines the historical development of public health approaches to the use of fluoride and comments on their effectiveness. Early research and developm......Dental caries remain a public health problem for many developing countries and for underprivileged populations in developed countries. This paper outlines the historical development of public health approaches to the use of fluoride and comments on their effectiveness. Early research...... and development was concerned with waterborne fluorides, both naturally occurring and added, and their effects on the prevalence and incidence of dental caries and dental fluorosis. In the latter half of the 20th century, the focus of research was on fluoride toothpastes and mouth rinses. More recently......, systematic reviews summarizing these extensive databases have indicated that water fluoridation and fluoride toothpastes both substantially reduce the prevalence and incidence of dental caries. We present four case studies that illustrate the use of fluoride in modern public health practice, focusing on...

  5. Synthesis of nanocrystalline mixed metal fluorides in nonaqueous medium

    Indian Academy of Sciences (India)

    Neetu Tyagi; Epsita Ghanti; Nikesh Gupta; N P Lalla; Rajamani Nagarajan

    2009-12-01

    Synthesis of mixed metal fluorides of the general formula, KMF3 (M = Mg, Mn, Co, Ni, Cu and Zn), possessing perovskite structure was investigated in non-aqueous medium. The fluorides were characterized by powder X-ray diffraction, FT–IR spectroscopy, thermal analysis, SEM and TEM. Monophasic cubic phases were obtained for the central metal ions such as Mg, Mn, Co, Ni, and Zn and a tetragonally distorted phase was observed for Cu. The usage of non-aqueous medium is advantageous for the bulk synthesis of these fluorides, since it eliminated the generation and handling of the hazardous HF that has usually been encountered during aqueous preparations. The average crystallite size of the fluorides obtained by this approach was estimated to be in the range of 9–30 nm. SEM micrographs of KZnF3 showed cubic morphology of perovskite phases. TEM studies on KCuF3 confirmed the presence of tetragonal distortion. The fluoride content was determined by titrimetry and found to be nearly stoichiometric. Some of these fluorides were found to be thermally stable up to 225°C in air. These fluorides were employed as fluorinating agents in organic fluorination reactions, thereby suggesting their possible utilization for selective fluorination of aliphatic and aromatic hydrofluorocarbons (HFCs) that are industrially relevant.

  6. Fluoride Levels of Mothers' Breast Milk in Egypt

    Directory of Open Access Journals (Sweden)

    Ghada, Z A Soliman and Tamer M M Saad

    2012-01-01

    Full Text Available Introduction: Fluoride exists naturally in water sources and is derived from fluorine. It is well known that fluoride helps, prevent and even reverse the early stages of tooth decay. Aim: The aim of the present study was to determine the fluoride levels in plasma and breast milk of lactating mothers in Egypt (Cairo and Giza Governorate. Material and Methods: Two hundred healthy lactating mothers aged between 20-40 years old were asked to give plasma and milk samples voluntary. Breast milk samples were directly refrigerated until measurements. The fluoride concentrations of plasma, milk and drinking tap water were assessed using an ion-selective fluoride electrode combined with an ion analyzer. Results: The fluoride levels of plasma, breast milk and drinking tap water samples were 0.0207±0.012, 0.0111±0.0044 ppm, and 0.482±0.117 ppm, respectively. A significant direct correlation between fluoride content in breast milk and drinking tap water was found (r=0.858, p< 0.01.

  7. Ful distil ation argon producing crud argon column on operating experience%全精馏制氩粗氩塔操作经验浅谈

    Institute of Scientific and Technical Information of China (English)

    马光显

    2015-01-01

    This paper briefly introduces the ful distil ation argon recovery process in the crude argon column in air separation system of cooling,heating and put some matters needing attention in use.%简要介绍了全精馏制氩过程中粗氩塔在空分系统降温、升温及投用中的一些注意事项。

  8. Amelioration of Fluoride Toxicity with the Use of Indigenous Inputs

    Directory of Open Access Journals (Sweden)

    Maitra A.

    2013-08-01

    Full Text Available An assessment was undertaken to study the efficacy of bacterial consortia isolated from different sources viz. rhizosphere of rice plant, oil spill sites of a petrol pump and from the sludge of a pharmaceutical waste water drain against the impact of fluoride. The experiments were conducted with two crops. In this mung bean experiment Vigna radiata was selected as a test crop. The seeds were sown in the field with bacterial consortia, compost and reduced dose (25% less nitrogen than recommended dose of chemical fertilizer. After 30days of seed sowing (DAS, plants were collected from the field and dipped into the sodium fluoride solution with different concentrations for 48 hours. Thereafter, the impact of fluoride on chlorophyll, sugar, proline and relative water content (% were evaluated. Scanning electron microscopy (SEM of the stem section was performed. SEM studies revealed that anatomical structure deformed with 1.5 mg/l sodium fluoride solution. It was observed that such treatment combination during the sowing of crops leads to combat the impact of lower doses of sodium fluoride (0.2 mg/l. Another experiment was also conducted within plastic pots with and without bacterial consortia isolated from rhizosphere of rice plant and oil spilled soil of petrol pump with the same field soil. Each pot was filled with 5 kg of soil + 2lt of water (on the basis of soil saturation. Oryza sativa seedlings were transplanted with different strength of sodium fluoride solution (25 mgNaF/kg, 50 mgNaF/kg, 100 mgNaF/kg and 500mgNaF/kg within the above pots. In second experiment, rice plants dried in all pots after 500 mgNaF/kg concentration of sodium fluoride. In this pot experiment bacterial strain are capable of reducing fluoride content in soil as noted by measuring fluoride in the pot soil after the experiment.

  9. Serum fluoride and sialic acid levels in osteosarcoma.

    Science.gov (United States)

    Sandhu, R; Lal, H; Kundu, Z S; Kharb, S

    2011-12-01

    Osteosarcoma is a rare malignant bone tumor most commonly occurring in children and young adults presenting with painful swelling. Various etiological factors for osteosarcoma are ionizing radiation, family history of bone disorders and cancer, chemicals (fluoride, beryllium, and vinyl chloride), and viruses. Status of fluoride levels in serum of osteosarcoma is still not clear. Recent reports have indicated that there is a link between fluoride exposure and osteosarcoma. Glycoproteins and glycosaminoglycans are an integral part of bone and prolonged exposure to fluoride for long duration has been shown to cause degradation of collagen and ground substance in bones. The present study was planned to analyze serum fluoride, sialic acid, calcium, phosphorus, and alkaline phosphatase levels in 25 patients of osteosarcoma and age- and sex-matched subjects with bone-forming tumours other than osteosarcoma and musculo-skeletal pain (controls, 25 each). Fluoride levels were analyzed by ISE and sialic acid was analyzed by Warren's method. Mean serum fluoride concentration was found to be significantly higher in patients with osteosarcoma as compared to the other two groups. The mean value of flouride in patients with other bone-forming tumors was approximately 50% of the group of osteosarcoma; however, it was significantly higher when compared with patients of group I. Serum sialic acid concentration was found to be significantly raised in patients with osteosarcoma as well as in the group with other bone-forming tumors as compared to the group of controls. There was, however, no significant difference in the group of patients of osteosarcoma when compared with group of patients with other bone-forming tumors. These results showing higher level of fluoride with osteosarcoma compared to others suggesting a role of fluoride in the disease.

  10. Pharmacokinetics of Fluoride in Toddlers After Application of 5% Sodium Fluoride Dental Varnish

    OpenAIRE

    Milgrom, Peter; Taves, Donald M.; Kim, Amy S.; Watson, Gene E; Jeremy A Horst

    2014-01-01

    The prevalence of dental caries (tooth decay) among preschool children is increasing, driven partially by an earlier age of onset of carious lesions. The American Academy of Pediatrics recommends application of 5% sodium fluoride varnish at intervals increasing with caries risk status, as soon as teeth are present. However, the varnishes are marketed for treatment of tooth sensitivity and are regulated as medical devices rather than approved by the US Food and Drug Administration for preventi...

  11. Fluoride varnishes with calcium glycerophosphate: fluoride release and effect on in vitro enamel demineralization

    Directory of Open Access Journals (Sweden)

    Thiago Saads CARVALHO

    2015-01-01

    Full Text Available The aims of this study were (1 to assess the amount of fluoride (F released from varnishes containing calcium glycerophosphate (CaGP and (2 to assess the effect of the experimental varnishes on in vitro demineralization. Six test groups using 5 varnishes: base varnish (no active ingredients; Duraphat® (2.26% NaF; Duofluorid® (5.63% NaF/CaF2; experimental varnish 1 (1% CaGP/5.63% NaF/CaF2; experimental varnish 2 (5% CaGP/5.63% NaF/CaF2; and no varnish were set up. In stage 1, 60 acrylic blocks were randomly distributed into 6 groups (n = 10. Then 300 µg of each varnish was applied to each block. The blocks were immersed in deionized water, which was changed after 1, 8, 12, 24, 48 and 72 hours. Fluoride concentration in the water was analyzed using a fluoride electrode. In stage 2, 60 bovine enamel samples were distributed into 6 groups (n = 10, and treated with 300 µg of the respective varnish. After 6 h the varnish was removed and the samples were subjected to a 7-day in vitro pH cycle (6 h demineralization/18 h remineralization per day. The demineralization was measured using surface hardness. The results showed that both experimental varnishes released more fluoride than Duofluorid® and Duraphat® (p < 0.05, but Duraphat® showed the best preventive effect by decreasing enamel hardness loss (p < 0.05. Therefore, we conclude that even though (1 the experimental varnishes containing CaGP released greater amounts of F, (2 they did not increase in the preventive effect against enamel demineralization.

  12. Graphene Fluoride: A Stable Stoichiometric Graphene Derivative and its Chemical Conversion to Graphene

    OpenAIRE

    Zbořil, Radek; Karlický, František; Bourlinos, Athanasios B.; Steriotis, Theodore A.; Athanasios K. Stubos; Georgakilas, Vasilios; Šafářová, Klára; Jančík, Dalibor; Trapalis, Christos; Otyepka, Michal

    2010-01-01

    Stoichoimetric graphene fluoride monolayers are obtained in a single step by the liquid-phase exfoliation of graphite fluoride with sulfolane. Comparative quantum-mechanical calculations reveal that graphene fluoride is the most thermodynamically stable of five studied hypothetical graphene derivatives; graphane, graphene fluoride, bromide, chloride, and iodide. The graphene fluoride is transformed into graphene via graphene iodide, a spontaneously decomposing intermediate. The calculated ban...

  13. Solubility of fluorides of alkaline earth metals and some rare earths in anhydrous trifluoroacetic acid

    International Nuclear Information System (INIS)

    Solubility of fluorides of alkaline earth and some rare earth metals in anhydrous trifluoroacetic acid is studied. For each type of fluoride solubility depends on the ionic radius of the cation. Solubility of fluorides of alkaline earth metals grows from magnesium to barium. All the fluorides in anhydrous trifluoroacetic acid form solvates. Solvates of strontium and scandium fluorides are shown to decompose at 110 and 150 deg C respectively

  14. Fluoride and lead adsorption on carbon nanotubes

    Institute of Scientific and Technical Information of China (English)

    WANG Shuguang; LI Yanhui

    2004-01-01

    The properties and applications of CNT have been studied extensively since Iijima discovered them in 1991[1,2]. They have exceptional mechanical properties and unique electrical property, highly chemical stability and large specific surface area. Thus far, they have widely potential applications in many fields. They can be used as reinforcing materials in composites[3], field emissions[4], hydrogen storage[5], nanoelectronic components[6], catalyst supports[7], adsorption material and so on. However, the study on the potential application of CNT, environmental protection field in particular, was hardly begun.Long[8] et al. reported that CNT had a significantly higher dioxin removal efficiency than that of activated carbon. The Langmuir adsorption constant is 2.7 × 1052, 1.3 × 1018 respectively. The results indicated that CNT is potential candidate for the removal of micro-organic pollutants. However, the reports on the CNT used as fluoride and heavy metal adsorbent are seldom.In this paper, A novel material, alumina supported on carbon nanotubes (Al2O3/CNT), was prepared from carbon nanotubes and Al(NO3)3. X-ray diffraction (XRD) spectra demonstrate that alumina is amorphous, and scanning electron microscope (SEM) images show that CNT and alumina are homogeneously mixed. Furthermore, the fluoride adsorption behavior on the surface of Al2O3/CNT has been investigated and compared with other adsorbents. The results indicate that Al2O3/CNT has a high adsorption capacity, with a saturation adsorption capacity of 39.4 mg/g. It is also found that the adsorption capacity of Al2O3/CNT is 3.0~4.5 times that of γ-Al2O3while almost equal to that of IRA-410 polymeric resin at 25 ℃. The adsorption isotherms of fluoride on Al2O3/CNT is fit the Freundlich equation well, optimal pH ranging from 5.0 to 9.0.Also in this paper, a novel material, modified carbon nanotubes (CNT), was prepared from carbon nanotubes and HNO3 under boiling condition. Infrared spectroscopy (IR

  15. Spectrophotometric determination of fluorides in water with Hach equipment

    International Nuclear Information System (INIS)

    The spectrophotometric method for the determination of the fluoride ion in water, demineralized water, raw waters, laundry waters and waters treated with ion exchange resins , using the technique and the SPADNS coloring indicated in the operation manual of the Hach equipment is described. This method covers the determination of the fluoride ion in the range from 0 to 2 mg/l on 25 ml. of radioactive base sample. These limits can be variable if the size of the used aliquot one is changed for the final determination of the fluoride ion. (Author)

  16. Nitrogen Trifluoride-Based Fluoride- Volatility Separations Process: Initial Studies

    Energy Technology Data Exchange (ETDEWEB)

    McNamara, Bruce K.; Scheele, Randall D.; Casella, Andrew M.; Kozelisky, Anne E.

    2011-09-28

    This document describes the results of our investigations on the potential use of nitrogen trifluoride as the fluorinating and oxidizing agent in fluoride volatility-based used nuclear fuel reprocessing. The conceptual process uses differences in reaction temperatures between nitrogen trifluoride and fuel constituents that produce volatile fluorides to achieve separations and recover valuable constituents. We provide results from our thermodynamic evaluations, thermo-analytical experiments, kinetic models, and provide a preliminary process flowsheet. The evaluations found that nitrogen trifluoride can effectively produce volatile fluorides at different temperatures dependent on the fuel constituent.

  17. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    Science.gov (United States)

    Sun, Wen-Ting; Li, Guo; Li, He-Ping; Bao, Cheng-Yu; Wang, Hua-Bo; Zeng, Shi; Gao, Xing; Luo, Hui-Ying

    2007-06-01

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images.

  18. First measurements with ARGONTUBE, a 5 m long drift Liquid Argon TPC

    International Nuclear Information System (INIS)

    The Liquid Argon Time Projection Chamber (LAr TPC) technique is a promising technology for future neutrino detectors. At LHEP of the University of Bern (Switzerland), an R and D program towards large detectors are on-going. The main goal is to show the feasibility of long drift paths over many meters. Therefore, a liquid Argon TPC with 5 m of drift distance was constructed. Many other aspects of the liquid Argon TPC technology are also investigated, such as a new device to generate high voltage in liquid Argon (Greinacher circuit), a recirculation filtering system and the multi-photon ionization of liquid Argon with a UV laser. Two detectors are built: a medium size prototype for specific detector technology studies, and ARGONTUBE, a 5 m long device

  19. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    International Nuclear Information System (INIS)

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images

  20. First measurement of the ionization yield of nuclear recoils in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, T. [Univ. of California, Berkeley, CA (United States). Dept. of Nuclear Engineering; Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Sangiorgio, Samuele [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Bernstein, A. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Foxe, Michael P. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical and Nuclear Engineering; Hagmann, Chris [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Jovanovic, Igor [Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical and Nuclear Engineering; Kazkaz, K. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Norman, E. B. [Univ. of California, Berkeley, CA (United States). Dept. of Nuclear Engineering; Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Pereverzev, S. V. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Rebassoo, Finn O. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Sorensen, Peter F. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)

    2014-05-01

    Liquid phase argon has long been used as a target medium for particle detection via scintillation light. Recently there has been considerable interest in direct detection of both hypothetical darkmatter particles and coherent elastic neutrino nucleus scattering. These as-yet unobserved neutral particle interactions are expected to result in a recoiling argon atom O(keV), generally referred to in the literature as a nuclear recoil. This prompts the question of the available electromagnetic signal in a liquid argon detector. In this Letter we report the first measurement of the ionization yield (Qy), detected electrons per unit energy, resulting from nuclear recoils in liquid argon, measured at 6.7 keV. This is also the lowest energy measurement of nuclear recoils in liquid argon.

  1. Management of Liver Cancer Argon-helium Knife Therapy with Functional Computer Tomography Perfusion Imaging.

    Science.gov (United States)

    Wang, Hongbo; Shu, Shengjie; Li, Jinping; Jiang, Huijie

    2016-02-01

    The objective of this study was to observe the change in blood perfusion of liver cancer following argon-helium knife treatment with functional computer tomography perfusion imaging. Twenty-seven patients with primary liver cancer treated with argon-helium knife and were included in this study. Plain computer tomography (CT) and computer tomography perfusion (CTP) imaging were conducted in all patients before and after treatment. Perfusion parameters including blood flows, blood volume, hepatic artery perfusion fraction, hepatic artery perfusion, and hepatic portal venous perfusion were used for evaluating therapeutic effect. All parameters in liver cancer were significantly decreased after argon-helium knife treatment (p liver tissue, but other parameters kept constant. CT perfusion imaging is able to detect decrease in blood perfusion of liver cancer post-argon-helium knife therapy. Therefore, CTP imaging would play an important role for liver cancer management followed argon-helium knife therapy.

  2. Determination of fluoride content in toothpaste using spectrophotometry

    Directory of Open Access Journals (Sweden)

    Susanti Pudji Hastuti

    2013-09-01

    Full Text Available Background: Intake excessive fluoride in children’s teeth are generally marked with white and brown patches. Excessive fluoride of more than 4.0 mg/L can cause a person suffering from poisoning, fragility of the bones (osteoporosis, liver and kidney damage. Knowledge about the spectrophotometry for determination method of fluoride content in commercially available toothpaste is very few. Purpose: The purposes of study were to examine the suitable method for fluoride extraction and to determine out the accuracy, precision, linearity, and stability of the measurement method of fluoride content in toothpaste. Methods: The suitable F extraction method was determined by the comparison among 3 methods of extraction; e.g. the dried samples were immersed in (1 distilled water, (2 96% HCl, and (3 96% HNO3; and the validation methods of measurement were the maximum wavelength, standart curve, accuracy test, precision test, and stability test. Results: Result showed that the fluoride extraction by using the concentrated HNO3 was found to have the highest levels of fluoride, followed by hydrochloric acid dissolution (HCl and distilled water, while the method of validation showed that SPADNS revealed the acceptable accuracy. Precision has the RSD ≤ 2.00%. Furthermore the stability test result showed that the measurement of fluoride less than 2 hours was still reliable. Conclusion: The study suggested that the best result of fluoride extraction from toothpaste could be gained by using concentrate HNO3, and the spectrophotometer (UV-Vis Mini Shimadzu U-1240 and SPADNS have the acceptable accuracy.Latar Belakang: Pemasukan fluoride yang berlebihan pada gigi anak ditandai dengan bercak putih dan coklat. Fluoride lebih dari 4.0 mg / L dapat menyebabkan seseorang menderita keracunan , kerapuhan tulang (osteoporosis, kerusakan hati dan ginjal. Pengetahuan tentang spektrofotometri untuk metode penentuan kadar fluoride dalam pasta gigi yang tersedia secara

  3. Using High Fluoride Concentration Products in Public Policy: A Rapid Review of Current Guidelines for High Fluoride Concentration Products.

    Science.gov (United States)

    Douglas, Gail V A; Ramsdale, Martin P; Vinall-Collier, Karen; Csikar, Julia I

    2016-01-01

    Despite improvements in dental caries levels since the widespread introduction of fluoride toothpastes, it is still a disease which is considered to be a priority in many countries around the world. Individuals at higher risk of caries can be targeted with products with a high fluoride concentration to help reduce the amount and severity of the disease. This paper compares guidance from around the world on the use of products with a high fluoride concentration and gives examples of how guidance has been translated into activity in primary care dental practice. A rapid review of electronic databases was conducted to identify the volume and variation of guidance from national or professional bodies on the use of products with a high fluoride concentration. Fifteen guidelines published within the past 10 years and in English were identified and compared. The majority of these guidelines included recommendations for fluoride varnish use as well as for fluoride gels, while a smaller number offered guidance on high fluoride strength toothpaste and other vehicles. Whilst there was good consistency in recommendations for fluoride varnish in particular, there was sometimes a lack of detail in other areas of recommendation for other vehicles with a high fluoride concentration. There are good examples within the UK, such as the Childsmile project and Delivering Better Oral Health, which highlight that the provision of evidence-based guidance can be influential in directing scarce resources towards oral health improvements. Policy can be influenced by evidence-based national recommendations and used to help encourage dental professionals and commissioners and third-party payers to adopt higher levels of practices aimed at oral health improvement. PMID:27100106

  4. Cerium fluoride crystals for calorimetry at LHC

    International Nuclear Information System (INIS)

    High-resolution homogeneous calorimetry is fully justified for part of the physics program at the Large Hadron Collider (LHC). The main design features of proposed CeF3 crystals for calorimetry for LHC are discussed. The severe constraints LHC imposes on detectors make the use of 'classical' crystals impossible. Therefore, a large R and D effort has been undertaken by the 'Crystal Clear' collaboration in order to find new, dense, fast and radiation hard crystals. A good candidate, cerium fluoride, has been identified and studied. It is interesting at this stage to review the specifications of scintillators for LHC and to see how well available data on CeF3 luminescence, decay time, light yield, optical transmission and resistance to radiation meet them. Milestones to reach before starting a large scale crystal production in view of the eventual construction of a calorimeter, are also discussed. (author) 15 refs., 15 figs., 1 tab

  5. Further results on cerium fluoride crystals

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.; Auffray, E.; Aziz, T.; Baccaro, S.; Banerjee, S.; Bareyre, P.; Barone, L.E.; Borgia, B.; Boutet, D.; Burq, J.P.; Chemarin, M.; Chipaux, R.; Dafinei, I.; D' Atanasio, P.; De Notaristefani, F.; Dezillie, B.; Dujardin, C.; Dutta, S.; Faure, J.L.; Fay, J.; Ferrere, D.; Francescangeli, O.; Fuchs, B.A.; Ganguli, S.N.; Gillespie, G.; Goyot, M.; Gupta, S.K.; Gurtu, A.; Heck, J.; Herve, A.; Hillemanns, H.; Holdener, F.; Ille, B.; Joensson, L.; Kierstead, J.; Krenz, W.; Kway, W.; Le Goff, J.M.; Lebeau, M.; Lebrun, P.; Lecoq, P.; Lemoigne, Y.; Loomis, G.; Lubelsmeyer, K.; Madjar, N.; Majni, G.; El Mamouni, H.; Mangla, S.; Mares, J.A.; Martin, J.P.; Mattioli, M.; Mauger, G.J.; Mazumdar, K.; Mengucci, P.; Merlo, J.P.; Moine, B.; Nikl, N.; Pansart, J.P.; Pedrini, C.; Poinsignon, J.; Polak, K.; Raghavan, R.; Rebourgeard, P.; Rinaldi, D.; Rosa, J.; Rosowsky, A.; Sahuc, P.; Samsonov, V.; Sarkar, S.; Schegelski, V.; Schmitz, D.; Schneegans, M.; Seliverstov, D.; Stoll, S.; Sudhakar, K.; Sven; Crystal Clear Collaboration

    1993-08-15

    A systematic investigation of the properties of cerium fluoride monocrystals has been performed by the 'Crystal Clear' collaboration in view of a possible use of such crystals for the construction of high precision electromagnetic calorimeters for the future generation of high luminosity accelerators. A large sample of different crystals grown by several producers has been studied. The spectroscopic characteristics, the transmission, luminescence and excitation spectra and the decay time curves are analysed. The light yield of the different crystals is measured with photomultipliers and Si photodiodes and compared to reference standards like BGO and NaI(Tl). The radiation damage behaviour is then presented for [gamma] and neutron irradiations, at different doses and dose rates, including thermal and optical bleaching. (orig.)

  6. Development of membrane cryostats for large liquid argon neutrino detectors

    CERN Document Server

    Montanari, D; Gendotti, A; Geynisman, M; Hentschel, S; Loew, T; Mladenov, D; Montanari, C; Murphy, S; Nessi, M; Norris, B; Noto, F; Rubbia, A; Sharma, R; Smargianaki, D; Stewart, J; Vignoli, C; Wilson, P; Wu, S

    2015-01-01

    A new collaboration is being formed to develop a multi-kiloton Long-Baseline neutrino experiment that will be located at the Surf Underground Research Facility (SURF) in Lead, SD. In the present design, the detector will be located inside cryostats filled with 68,400 ton of ultrapure liquid argon (less than 100 parts per trillion of oxygen equivalent contamination). To qualify the membrane technology for future very large-scale and underground implementations, a strong prototyping effort is ongoing: several smaller detectors of growing size with associated cryostats and cryogenic systems will be designed and built at Fermilab and CERN. They will take physics data and test different detector elements, filtration systems, design options and installation procedures. In addition, a 35 ton prototype is already operational at Fermilab and will take data with single-phase detector in early 2016. After the prototyping phase, the multi-kton detector will be constructed. After commissioning, it will detect and study ne...

  7. Fluorescence Spectrum of SiO in an Argon Matrix

    Science.gov (United States)

    Scullman, R.; Hormes, J.; Schroeder, W.; Wiggenhauser, H.

    1987-04-01

    Fluorescence from SiO matrix isolated in argon has been investigated in the wavelength region 120-300 nm. Fluorescence emission spectra from the valence states, A1Π, E1Σ+ and G1Π, revealed that nearly all radiation comes from one channel at 305 nm, which was analysed as originating from the b3Π-X1Σ+ transition. Contrary to the A1Π and G1Π states, the E1Σ+ state also decays radiatively, although weakly, through two other channels situated in the vicinity of 305 nm. These two channels were believed to originate from the a3Σ+-X1Σ+ and e3Σ--X1Σ+ transitions.

  8. Electron Neutrino Classification in Liquid Argon Time Projection Chamber Detector

    CERN Document Server

    Płoński, Piotr; Sulej, Robert; Zaremba, Krzysztof

    2015-01-01

    Neutrinos are one of the least known elementary particles. The detection of neutrinos is an extremely difficult task since they are affected only by weak sub-atomic force or gravity. Therefore large detectors are constructed to reveal neutrino's properties. Among them the Liquid Argon Time Projection Chamber (LAr-TPC) detectors provide excellent imaging and particle identification ability for studying neutrinos. The computerized methods for automatic reconstruction and identification of particles are needed to fully exploit the potential of the LAr-TPC technique. Herein, the novel method for electron neutrino classification is presented. The method constructs a feature descriptor from images of observed event. It characterizes the signal distribution propagated from vertex of interest, where the particle interacts with the detector medium. The classifier is learned with a constructed feature descriptor to decide whether the images represent the electron neutrino or cascade produced by photons. The proposed ap...

  9. Large area liquid argon detectors for interrogation systems

    Energy Technology Data Exchange (ETDEWEB)

    Gary, Charles; Kane, Steve; Firestone, Murray I.; Smith, Gregory [Adelphi Technology LLC, Purdue Technology Center, 5225 Exploration Drive, Indianapolis, IN 46241 (United States); Gozani, Tsahi; Brown, Craig; Kwong, John; King, Michael J. [Rapiscan Laboratories, 520 Almanor Avenue, Sunnyvale, CA 94085 (United States); Nikkel, James A.; McKinsey, Dan [Physics Department, Yale University, New Haven, CT 06520 (United States)

    2013-04-19

    Measurements of the efficiency, pulse shape, and energy and time resolution of liquid argon (LAr) detectors are presented. Liquefied noble gas-based (LNbG) detectors have been developed for the detection of dark matter and neutrinoless double-beta decay. However, the same qualities that make LNbG detectors ideal for these applications, namely their size, cost, efficiency, pulse shape discrimination and resolution, make them promising for portal screening and the detection of Special Nuclear Materials (SNM). Two 18-liter prototype detectors were designed, fabricated, and tested, one with pure LAr and the other doped with liquid Xe (LArXe). The LArXe detector presented the better time and energy resolution of 3.3 ns and 20% at 662 KeV, respectively. The total efficiency of the detector was measured to be 35% with 4.5% of the total photons detected in the photopeak.

  10. Argon plasma coagulation for treatment of hemorrhagic radiation gastroduodenitis

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Shu-Ji; Aoyama, Nobuo; Shirasaka, Daisuke; Inoue, Takashi; Kuroda, Kohei; Ebara, Shigeyuki; Tamura, Takao; Miyamoto, Masaki; Kasuga, Masato [Kobe Univ. (Japan). Graduate School of Medicine

    2002-01-01

    A 79-year-old man who had received radiotherapy for portal vein thrombosis due to hepatocellular carcinoma (HCC) 5 months earlier, showed progressive anemia and melena. Endoscopy on admission revealed diffuse bleeding from multiple telangiectasias on the anterior wall of the antrum and bulbus. We treated this patient with a new non-contact hemostatic method: the argon plasma coagulator (APC). The melena stopped after the first session and the hemoglobin level remained stable for 7 months. No delayed complications have been observed. Gastrointestinal bleeding from chronic radiation gastroduodenitis is rarely reported compared with radiation proctitis. This case demonstrates that APC is effective for hemostasis of diffuse bleeding from radiation gastroduodenitis, just as for radiation protitis. (author)

  11. Line ratio diagnostics in helium and helium seeded argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, R F [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Loch, S D [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Ballance, C P [Physics Department, Rollins College, White Park, FL 32789 (United States); Branscomb, D [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Pindzola, M S [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States)

    2007-08-15

    We investigate the potential use of line ratio diagnostics to evaluate electron temperature in either helium or helium seeded argon plasmas. Plasmas are produced in a helicon plasma source. A rf compensated Langmuir probe is used to measure both the electron temperature and plasma density while a spectrometer is used to measure He I line intensities from the plasma. For all plasma densities where the electron temperature remains at 5 {+-} 1 eV, three He line ratios are measured. Each experimental ratio is compared with the prediction of three different collisional radiative models. One of these models makes uses of recent R-matrix with pseudo-states calculations for collisional rate coefficients. A discussion related to the different observations and model predictions is presented.

  12. Photodegradation Mechanisms of Tetraphenyl Butadiene Coatings for Liquid Argon Detectors

    CERN Document Server

    Jones, B J P; Conrad, J M; Pla-Dalmau, A

    2013-01-01

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone (BP). We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  13. Kinetic modeling of the Townsend breakdown in argon

    Energy Technology Data Exchange (ETDEWEB)

    Macheret, S. O.; Shneider, M. N. [Department of Mechanical and Aerospace Engineering, Princeton University, D-414 Engineering Quadrangle, Princeton, New Jersey 08544 (United States)

    2013-10-15

    Kinetic modeling of the Townsend breakdown in argon was performed in the “forward-back” approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  14. Uranium (III) precipitation in molten chloride by wet argon sparging

    Science.gov (United States)

    Vigier, Jean-François; Laplace, Annabelle; Renard, Catherine; Miguirditchian, Manuel; Abraham, Francis

    2016-06-01

    In the context of pyrochemical processes for nuclear fuel treatment, the precipitation of uranium (III) in molten salt LiCl-CaCl2 (30-70 mol%) at 705 °C is studied. First, this molten chloride is characterized with the determination of the water dissociation constant. With a value of 10-4.0, the salt has oxoacid properties. Then, the uranium (III) precipitation using wet argon sparging is studied. The salt is prepared using UCl3 precursor. At the end of the precipitation, the salt is totally free of solubilized uranium. The main part is converted into UO2 powder but some uranium is lost during the process due to the volatility of uranium chloride. The main impurity of the resulting powder is calcium. The consequences of oxidative and reductive conditions on precipitation are studied. Finally, coprecipitation of uranium (III) and neodymium (III) is studied, showing a higher sensitivity of uranium (III) than neodymium (III) to precipitation.

  15. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    Science.gov (United States)

    Efthymiopoulos, Ilias

    2001-04-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs.

  16. Characterization of SF6/Argon Plasmas for Microelectronics Applications; TOPICAL

    International Nuclear Information System (INIS)

    This report documents measurements in inductively driven plasmas containing SF(sub 6)/Argon gas mixtures. The data in this report is presented in a series of appendices with a minimum of interpretation. During the course of this work we investigated: the electron and negative ion density using microwave interferometry and laser photodetachment; the optical emission; plasma species using mass spectrometry, and the ion energy distributions at the surface of the rf biased electrode in several configurations. The goal of this work was to assemble a consistent set of data to understand the important chemical mechanisms in SF(sub 6) based processing of materials and to validate models of the gas and surface processes

  17. Photodegradation mechanisms of tetraphenyl butadiene coatings for liquid argon detectors

    Science.gov (United States)

    Jones, B. J. P.; VanGemert, J. K.; Conrad, J. M.; Pla-Dalmau, A.

    2013-01-01

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone. We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  18. Liquid Argon Cryogenic Detector Calibration by Inelastic Scattering of Neutrons

    CERN Document Server

    Polosatkin, Sergey; Dolgov, Alexander

    2014-01-01

    A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron generator. Features of kinematics of inelastic scattering cause sufficient (forty times) increase in count rate of useful events relative to traditional scheme exploited elastic scattering with the same recoil energy and compatible energy resolution. The benefits of the proposed scheme of calibration most well implemented with the use of tagged neutron generator as a neutron source that allows to eliminate background originated from casual coincidence of signals on cryogenic detector and additional detector of scattered neutrons.

  19. The liquid argon TPC for the ICARUS experiment

    CERN Document Server

    Arneodo, F

    1997-01-01

    The ICARUS project aims at the realisation of a large liquid argon TPC to be run at the Underground Laboratories of Gran Sasso in Italy. An intense R&D; activity has put on firm grounds this new detector technology and experimentally confirmed its feasibility on a few ton scale. Based on these solid achievements, the collaboration is now confident of being able to build and safely operate a multi-kton detector. The reseach program of the experiment involves the systematic study of a wide spectrum of physical phenomena covering many orders of magnitude in the energy deposited in the detector: from the few MeV of solar neutrino interactions, to the about one GeV of the proton decay and atmospheric neutrinos, up to the higher energies of neutrinos from accelerators.

  20. Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

    CERN Document Server

    Aharrouche, M; Di Ciaccio, L; El Kacimi, M; Gaumer, O; Gouanère, M; Goujdami, D; Lafaye, R; Laplace, S; Le Maner, C; Neukermans, L; Perrodo, P; Poggioli, L; Prieur, D; Przysiezniak, H; Sauvage, G; Wingerter-Seez, I; Zitoun, R; Lanni, F; Lü, L; Ma, H; Rajagopalan, S; Takai, H; Belymam, A; Benchekroun, D; Hakimi, M; Hoummada, A; Gao, Y; Stroynowsk, R; Aleksa, M; Carli, T; Fassnacht, P; Gianotti, F; Hervás, L; Lampl, W; Collot, J; Hostachy, J Y; Ledroit-Guillon, F; Malek, F; Martin, P; Viret, S; Leltchouk, M; Parsons, J A; Simion, S; Barreiro, F; Del Peso, J; Labarga, L; Oliver, C; Rodier, S; Barrillon, P; Benchouk, C; Djama, F; Hubaut, F; Monnier, E; Pralavorio, P; Sauvage, D; Serfon, C; Tisserant, S; Tóth, J; Banfi, D; Carminati, L; Cavalli, D; Costa, G; Delmastro, M; Fanti, M; Mandell, L; Mazzanti, M; Tartarelli, F; Kotov, K; Maslennikov, A; Pospelov, G; Tikhonov, Yu; Bourdarios, C; Fayard, L; Fournier, D; Iconomidou-Fayard, L; Kado, M; Parrour, G; Puzo, P; Rousseau, D; Sacco, R; Serin, L; Unal, G; Zerwas, D; Dekhissi, B; Derkaoui, J; EL Kharrim, A; Maaroufi, F; Cleland, W; Lacour, D; Laforge, B; Nikolic-Audit, I; Schwemling, Ph; Ghazlane, H; Cherkaoui El Moursli, R; Idrissi Fakhr-Eddine, A; Boonekamp, M; Kerschen, N; Mansoulié, B; Meyer, P; Schwindlingy, J; Lund-Jensen, B

    2007-01-01

    The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

  1. A Thermodynamic Model for Argon Plasma Kernel Formation

    Directory of Open Access Journals (Sweden)

    James Keck

    2010-11-01

    Full Text Available Plasma kernel formation of argon is studied experimentally and theoretically. The experiments have been performed in a constant volume cylindrical vessel located in a shadowgraph system. The experiments have been done in constant pressure. The energy of plasma is supplied by an ignition system through two electrodes located in the vessel. The experiments have been done with two different spark energies to study the effect of input energy on kernel growth and its properties. A thermodynamic model employing mass and energy balance was developed to predict the experimental data. The agreement between experiments and model prediction is very good. The effect of various parameters such as initial temperature, initial radius of the kernel, and the radiation energy loss have been investigated and it has been concluded that initial condition is very important on formation and expansion of the kernel.

  2. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    CERN Document Server

    Efthymiopoulos, I

    2001-01-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs. (3 refs).

  3. Attosecond Coherent Control of Single and Double Photoionization in Argon.

    Science.gov (United States)

    Hogle, C W; Tong, X M; Martin, L; Murnane, M M; Kapteyn, H C; Ranitovic, P

    2015-10-23

    Ultrafast high harmonic beams provide new opportunities for coherently controlling excitation and ionization processes in atoms, molecules, and materials on attosecond time scales by employing multiphoton two-pathway electron-wave-packet quantum interferences. Here we use spectrally tailored and frequency tuned vacuum and extreme ultraviolet harmonic combs, together with two phase-locked infrared laser fields, to show how the total single and double photoionization yields of argon can be coherently modulated by controlling the relative phases of both optical and electronic-wave-packet quantum interferences. This Letter is the first to apply quantum control techniques to double photoionization, which is a fundamental process where a single, high-energy photon ionizes two electrons simultaneously from an atom. PMID:26551112

  4. Dynamic resonances and tunnelling in the multiphoton ionization of argon

    International Nuclear Information System (INIS)

    We present results of wavepacket simulations for multiphoton ionization in argon. A single active electron model is applied to estimate the single-electron ionization rates and photoelectron energy distributions for λ = 390 nm light with intensities up to I = 2 x 1014 W cm-2. The multiphoton ionization rates are compared with R-matrix Floquet calculations and found to be in very good agreement. The photoelectron energy distribution is used to study the nature of ionization at the higher intensities. Our results are consistent with recent calculations and experiments which show the imprint of the tunnelling process in the multiphoton regime. For few-cycle intense pulses, we find that the strong modulation of intensity and increased bandwidth leads to dynamic mixing of the 3d and 5s resonances.

  5. The ATLAS liquid Argon calorimeters read-out system

    CERN Document Server

    Blondel, A; Fayard, L; La Marra, D; Léger, A; Matricon, P; Perrot, G; Poggioli, L; Prast, J; Riu, I; Simion, S

    2004-01-01

    The calorimetry of the ATLAS experiment takes advantage of different detectors based on the liquid Argon (LAr) technology. Signals from the LAr calorimeters are processed by various stages before being delivered to the Data Acquisition system. The calorimeter cell signals are received by the front-end boards, which digitize a predetermined number of samples of the bipolar waveform and sends them to the Read-Out Driver (ROD) boards. The ROD board receives triggered data from 1028 calorimeter cells, and determines the precise energy and timing of the signals by processing the discrete samplings of the pulse. In addition, it formats the digital stream for the following elements of the DAQ chain, and performs monitoring. The architecture and functionality of the ATLAS LAr ROD board are discussed, along with the final design of the Processing Unit boards housing the Digital Signal Processors (DSP). (9 refs).

  6. Electron-ion recombination study in argon at atmospheric pressure

    International Nuclear Information System (INIS)

    This study deals with a wall-stabilized arc burning in argon at atmospheric pressure. A transient mode is obtained using a fast thyristor connected to the electrodes, which short-circuits the discharge. By means of two wavelengths laser interferometry and spectroscopy measurements we have determined the temporal changes of the electron density, ground state atom density and excited atom density. We have shown that, when the electric field is suppressed, the electron temperature rapidly decreases to the gas temperature before changing electron and atom densities. This phenomenon is applied to determine the gas temperature and to evaluate the role played by ionization in electron density balance. The coefficients of ambipolar diffusion, ionization and recombination and an apparent recombination coefficient are determined versus electron temperature and compared with theoretical values

  7. Atmospheric dispersion of argon-41 from anuclear research reactor: measurement and modeling of plume geometry and gamma radiation field

    DEFF Research Database (Denmark)

    Lauritzen, Bent; Astrup, Poul; Drews, Martin;

    2003-01-01

    An atmospheric dispersion experiment was conducted using a visible tracer along with the routine release of argon-41 from the BR1 research reactor in Mol, Belgium. Simultaneous measurements of plume geometry and radiation fields for argon-41 decay were performed as well as measurements of the argon...

  8. A highly sensitive colorimetric and ratiometric sensor for fluoride ion

    Institute of Scientific and Technical Information of China (English)

    Zhao Wu Xu; Jin Tang; He Tian

    2008-01-01

    A new benzoimidazole-naphthalimide derivative 4 was synthesized and its photophysical properties were studied.This compound showed highly selectively and sensitive colorimetric and ratiometric sensing ability for fluoride anion.

  9. Preparation and Characterization of Rare Earth Doped Fluoride Nanoparticles

    Directory of Open Access Journals (Sweden)

    Timothy A. DeVol

    2010-03-01

    Full Text Available This paper reviews the synthesis, structure and applications of metal fluoride nanoparticles, with particular focus on rare earth (RE doped fluoride nanoparticles obtained by our research group. Nanoparticles were produced by precipitation methods using the ligand ammonium di-n-octadecyldithiophosphate (ADDP that allows the growth of shells around a core particle while simultaneously avoiding particle aggregation. Nanoparticles were characterized on their structure, morphology, and luminescent properties. We discuss the synthesis, properties, and application of heavy metal fluorides; specifically LaF3:RE and PbF2, and group IIA fluorides. Particular attention is given to the synthesis of core/shell nanoparticles, including selectively RE-doped LaF3/LaF3, and CaF2/CaF2 core/(multi-shell nanoparticles, and the CaF2-LaF3 system.

  10. Estuarine response of fluoride - Investigations in Azhikode Estuary

    Digital Repository Service at National Institute of Oceanography (India)

    Balachandran, K.K.; Joseph, T.; Sankaranarayanan, V.N.

    behaved conservatively during the postmonsoon season. However, during the premonsoon season 25% removal of fluoride was observed due to estuarine mixing. The possible mechanisms for the removal are explained....

  11. Quantitative measure for the "nakedness" of fluoride ion sources.

    Science.gov (United States)

    Christe, Karl O; Jenkins, H Donald Brooke

    2003-08-01

    A quantitative measure for the donor strength or "nakedness" of fluoride ion donors is presented. It is based on the free energy change associated with the transfer of a fluoride ion from the donor to a given acceptor molecule. Born-Haber cycle calculations were used to calculate both the free energy and the enthalpy change for this process. The enthalpy change is given by the sum of the fluoride ion affinity of the acceptor (as defined in strict thermodynamic convention) and the lattice energy difference (DeltaU(POT)) between the fluoride ion donor and the salt formed with the acceptor. Because, for a given acceptor, the fluoride affinity has a constant value, the relative enthalpy (and also the corresponding free energy) changes are governed exclusively by the lattice energy differences. In this study, BF(3), PF(5), AsF(5), and SbF(5) were used as the acceptors, and the following seven fluoride ion donors were evaluated: CsF, N(CH(3))(4)F (TMAF), N-methylurotropinium fluoride (MUF), hexamethylguanidinium fluoride (HMGF), hexamethylpiperidinium fluoride (HMPF), N,N,N-trimethyl-1-adamantylammonium fluoride (TMAAF), and hexakis(dimethylamino)phosphazenium fluoride (HDMAPF). Smooth relationships between the enthalpy changes and the molar volumes of the donor cations were found which asymptotically approach constant values for infinitely large cations. Whereas CsF is a relatively poor F(-) donor [(U(POT)(CsF) - U(POT)(CsSbF(6))) = 213 kJ mol(-)(1)], when compared to N(CH(3))(4)F [(U(POT)(TMAF) - U(POT)(TMASbF(6))) = 69 kJ mol(-)(1)], a 4 times larger cation (phosphazenium salt) and an infinitely large cation are required to decrease DeltaU(POT) to 17 and 0 kJ mol(-)(1), respectively. These results clearly demonstrate that very little is gained by increasing the cation size past a certain level and that secondary factors, such as chemical and physical properties, become overriding considerations.

  12. EXPERIMENTAL STUDY AND NUMERICAL SIMULATION OF FLUORIDE IN SAND

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong-mei; SU Bao-yu

    2006-01-01

    The transport and transformation of fluoride in sand were studied by using soil tank test under the condition of saturated water in this article. Based on the analysis of the laboratory experiments, the rules of fluorine transportation and transformation were simulated in sand by solving the advection-diffusion equation. Through comparison between computed results and observed data , it is shown that the established model and determined parameters could be used to simulate the fluoride transport in sand.

  13. Preparation and Characterization of Rare Earth Doped Fluoride Nanoparticles

    OpenAIRE

    DeVol, Timothy A.; Basak Yazgan-Kukouz; Baris Kokuoz; DiMaio, Jeffrey R.; Kevin B. Sprinkle; James, Tiffany L.; Kucera, Courtney J.; Jacobsohn, Luiz G.; John Ballato

    2010-01-01

    This paper reviews the synthesis, structure and applications of metal fluoride nanoparticles, with particular focus on rare earth (RE) doped fluoride nanoparticles obtained by our research group. Nanoparticles were produced by precipitation methods using the ligand ammonium di-n-octadecyldithiophosphate (ADDP) that allows the growth of shells around a core particle while simultaneously avoiding particle aggregation. Nanoparticles were characterized on their structure, morphology, and luminesc...

  14. Thermodynamic investigation of fluoride salts for nuclear energy production

    OpenAIRE

    Beilmann, Markus

    2013-01-01

    In this work thermodynamic properties of molten fluoride salts and salt mixtures are investigated. Fluoride salts have advantageous properties to be used in energy producing systems based on the conversion from heat to energy like i.e in Molten Salt Reactors. For this purpose it is very important to have detailed information about the heat capacity of the pure salts and salt mixtures. To get a better understanding about the heat capacity in mixtures drop calorimetry measurements of mixture...

  15. Fluoride-assisted synthesis of bimodal microporous SSZ-13 zeolite.

    Science.gov (United States)

    Zhu, Xiaochun; Kosinov, Nikolay; Hofmann, Jan P; Mezari, Brahim; Qian, Qingyun; Rohling, Roderigh; Weckhuysen, Bert M; Ruiz-Martínez, Javier; Hensen, Emiel J M

    2016-02-21

    The presence of small amount of fluoride in alkaline hydrothermal synthesis of SSZ-13 zeolite yields bimodal microporous particles with substantially improved performance in the methanol-to-olefins (MTO) reaction. Hydrocarbon uptake measurements and fluorescence microspectroscopy of spent catalysts demonstrate enhanced diffusion through micropores at the grain boundaries of nanocrystals running through the zeolite particles. Fluoride-assisted SSZ-13 synthesis is a cheap and scalable approach to optimize the performance of MTO zeolite catalysts. PMID:26810114

  16. Heterolysis of Dihydrogen by Silver Alkoxides and Fluorides.

    Science.gov (United States)

    Tate, Brandon K; Nguyen, Jenna T; Bacsa, John; Sadighi, Joseph P

    2015-07-01

    Alkoxide-bridged disilver cations react with dihydrogen to form hydride-bridged cations, releasing free alcohol. Hydrogenolysis of neutral silver fluorides affords hydride-bridged disilver cations as their bifluoride salts. These reactions proceed most efficiently when the supporting ligands are expanded N-heterocyclic carbenes (NHCs) derived from 6- and 7-membered cyclic amidinium salts. Kinetics studies show that silver fluoride hydrogenolysis is first-order in both silver and dihydrogen.

  17. The economic value of Quebec’s water fluoridation program

    OpenAIRE

    Tchouaket, Eric; Brousselle, Astrid; Fansi, Alvine; Dionne, Pierre Alexandre; Bertrand, Elise; Fortin, Christian

    2013-01-01

    Aim Dental caries is a major public health problem worldwide, with very significant deleterious consequences for many people. The available data are alarming in Canada and the province of Quebec. The water fluoridation program has been shown to be the most effective means of preventing caries and reducing oral health inequalities. This article analyzes the cost-effectiveness of Quebec’s water fluoridation program to provide decision-makers with economic information for assessing its usefulnes...

  18. Fluoride Concentration in Drinking Water Resources; North of Iran

    Directory of Open Access Journals (Sweden)

    Amouei A.I. PhD,

    2016-03-01

    Full Text Available Aims Fluoride is one of the anions present in soil and water, and determining its level in drinking water is vital for preventing dental and bone diseases in societies. This research aimed to determine fluoride concentrations in drinking water sources of rural and urban areas of Babol City, Iran. Instrument & Methods This descriptive cross-sectional study was conducted in Babol City, Iran, in 2014. 384 water samples were taken from 43 wells and 3 springs in the rural areas, and from 20 wells, 3 water reservoirs, and the water distribution system in the urban areas. Fluoride concentrations of water samples were measured with a model DR2000 spectrophotometer using the standard SPADNS method. Data were entered to SPSS 16 software and were analyzed by ANOVA test. Findings The mean fluoride concentrations in the water samples of the deep wells were higher compared to those of the springs (p=0.01. The mean fluoride concentrations in the plains areas were higher compared to the mountainous regions (p=0.02. The mean fluoride concentrations in the wells of the urban areas, in the urban reservoirs, and in the urban water distribution system were 0.40±0.14, 0.39±0.15, and 0.40±0.15mg/l, respectively (p=0.07. Fluoride concentrations in water in urban areas during various seasons varied from 0.31 to 0.45mg/l (p=0.06. Conclusion Fluoride concentrations in all drinking water sources in urban and rural areas of Babol are less than the ranges recommended by WHO and Iranian national standards.

  19. Scientific Opinion on Dietary Reference Values for fluoride

    OpenAIRE

    EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA)

    2013-01-01

    Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA) derived Dietary Reference Values (DRVs) for fluoride, which are provided as Adequate Intake (AI) from all sources, including non-dietary sources. Fluoride is not an essential nutrient. Therefore, no Average Requirement for the performance of essential physiological functions can be defined. Nevertheless, the Panel considered that the setting of an AI is appropriate because of the be...

  20. Corrosion behavior of zirconia in acidulated phosphate fluoride

    OpenAIRE

    Anie Thomas; Sathyanarayanan Sridhar; Shant Aghyarian; Pilanda Watkins-curry; Chan, Julia Y.; Alessandro Pozzi; Danieli C. Rodrigues

    2016-01-01

    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all specimens were imaged using digital microscopy and scanning electron microscopy (SEM). Sample mass and dimensions were measured for mass loss determination. Samples were charac...

  1. Corrosion behavior of zirconia in acidulated phosphate fluoride

    OpenAIRE

    Thomas, Anie; Sridhar, Sathyanarayanan; Aghyarian, Shant; Watkins-Curry, Pilanda; Chan, Julia Y.; Pozzi, Alessandro; Danieli C. Rodrigues

    2016-01-01

    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all specimens were imaged using digital microscopy and scanning electron microscopy (SEM). Sample mass and dimensions were measured for mass loss determination. Samples were characteri...

  2. Fluoride levels in commercial dentifrices and drinking Water in Algeria

    OpenAIRE

    MERGHACHE, D.; BELLOUT, B.; MERGHACHE, S.; BOUCHERIT-ATMANI, Z.

    2011-01-01

    More and more scientific evidence show that fluorides have a cariostatic action to the plaque-saliva-tooth interface during cariogenous dissolution. Fluorides slow down demineralization and enhance remineralization. Their action is optimal, in the oral environment, when used at low concentrations on a continuous basis. The use of the fluorinated toothpastes during brushing of the teeth is a simple, rational method of daily topics application of fluorine, largely used in the context of prevent...

  3. Removal of fluoride from water using aluminium containing compounds

    Institute of Scientific and Technical Information of China (English)

    M. Karthikeyan; K. P. Elango

    2009-01-01

    Batch adsorption studies were undertaken to assess the suitability of aluminium titanate (AT) and bismuth aluminate (BA) to remove fluoride ions from water.The effect of pH,dose of adsorbent,contact time,initial concentration,co-ions and temperature on fluoride removal efficiency were studied.The amounts of fluoride ions adsorbed,at 30℃ from 4 mg/L of fluoride ion solution,by AT and BA are 0.85 and 1.55 mg/g,respectively.The experimental data fitted well to the Freundlich and Langmuir isotherms.Thermodynamic parameters such as △H~0,△S~0 and △G~0 indicated that the removal of fluoride ions by AT is exothermic and non-spontaneous while that by BA is endothermic and spontaneous.Furrier transform infrared (FT-IR) analysis and X-ray diffraction (XRD) patterns of the adsorbent before and after adsorption indicated that fluoride ions are chemisorbed by these adsorbents.

  4. Preparation of mixed rare earths modified chitosan for fluoride adsorption

    Institute of Scientific and Technical Information of China (English)

    梁鹏; 张艺; 汪东风; 徐莹; 罗斓

    2013-01-01

    This paper described the fluoride removal from water using a new adsorbent namely mixed rare earths modified chitosan (CR). Mixed rare earths mainly contained La followed by Ce which was analyzed by inductively coupled plasma mass spectrometry (ICP-MS). La(III)-modified chitosan (CL) was also prepared as control. For the batch technique, the effects of various parameters such as contact time, pH, adsorbent dose, initial fluoride concentration and co-ions on fluoride adsorption were studied. Fourier trans-form infrared spectroscopy (FTIR) and X-ray diffraction (XRD) were used to characterize adsorbents. It was observed that the fluo-ride adsorption capacity of CR (3.72 mgF-/g) was higher than CL (3.16 mgF-/g) at 2 h. The presence of co-ions such as bicarbonate and carbonate greatly affected the fluoride adsorption from water. Characterization experiments indicated the successful chelation between mixed rare earths and chitosan. The possible fluoride adsorption mechanism of CR was explained by a chemical reaction.

  5. Phosphate reduction in a hydroxyapatite fluoride removal system

    Science.gov (United States)

    Egner, A.

    2012-12-01

    Fluorosis is a widespread disease that occurs as a result of excess fluoride consumption and can cause severe tooth and bone deformations. To combat fluorosis, several previous studies have examined the potential to replace traditional bone char filters with synthetic hydroxyapatite. Calcite particles with a synthetic hydroxyapatite coating have been shown to effectively removed fluoride, yet the low-cost method for forming these particles leaves high amounts of phosphate both in synthesis waste-water and in filter effluent. High phosphate in filter effluent is problematic because consumption of extremely high phosphate can leach calcium from bones, further exacerbating the fluoride effect. This study examines ways of reducing and reusing waste. In particular, a method of fluoride removal is explored in which fluorapatite coatings may be formed directly. In preliminary studies, batches of 4.1g of Florida limestone (<710 μm) were equilibrated with 100 mL of 10ppm fluoride. In a control batch containing lime but no added phosphate, 14% treatment was achieved, but with added phosphate, 100% treatment was achieved in all batches. Batches with lower levels of phosphate took longer to reach 100% treatment, ranging from less than 24 hours in the highest phosphate batches to approximately 42 hours in the lowest batches. The lower levels tested were well within reasonable levels for drinking water and reached 0ppm fluoride in 42 hours or less.

  6. Community Water Fluoridation and Intelligence: Prospective Study in New Zealand.

    Science.gov (United States)

    Broadbent, Jonathan M; Thomson, W Murray; Ramrakha, Sandhya; Moffitt, Terrie E; Zeng, Jiaxu; Foster Page, Lyndie A; Poulton, Richie

    2015-01-01

    Objectives. This study aimed to clarify the relationship between community water fluoridation (CWF) and IQ. Methods. We conducted a prospective study of a general population sample of those born in Dunedin, New Zealand, between April 1, 1972, and March 30, 1973 (95.4% retention of cohort after 38 years of prospective follow-up). Residence in a CWF area, use of fluoride dentifrice and intake of 0.5-milligram fluoride tablets were assessed in early life (prior to age 5 years); we assessed IQ repeatedly between ages 7 to 13 years and at age 38 years. Results. No clear differences in IQ because of fluoride exposure were noted. These findings held after adjusting for potential confounding variables, including sex, socioeconomic status, breastfeeding, and birth weight (as well as educational attainment for adult IQ outcomes). Conclusions. These findings do not support the assertion that fluoride in the context of CWF programs is neurotoxic. Associations between very high fluoride exposure and low IQ reported in previous studies may have been affected by confounding, particularly by urban or rural status.

  7. Fluoride release from restorative materials coated with an adhesive.

    Science.gov (United States)

    Miranda, Letícia Algarves; Weidlich, Patrícia; Samuel, Susana Maria Werner; Maltz, Marisa

    2002-01-01

    The retention of both fluoride resins and resin-modified glass ionomer cements to dental tissues can be improved by the association of an adhesive system which promotes the bonding between the resin component and dentin, forming a hybrid layer. The purpose of this investigation was to evaluate if the presence of the adhesive, being part of the hybrid layer composition, interfered with the fluoride released to tooth tissues. The restorative materials studied were: Vitremer (3M), Heliomolar (Vivadent) and Z100 (3M) using an adhesive application (Scotch Bond MultiPurpose Plus--3M). Ten discs of each material were prepared: 5 were covered with the adhesive and 5 were not. The discs were immersed in individual flasks containing artificial saliva which was changed daily. Fluoride release was measured at days 1, 5, 10, 15 and 20 by a fluoride combined electrode (9609 BN--Orion) coupled to an ion analyzer (SA-720 Procyon). One-way ANOVA and the Student-Newman-Keuls test were applied to compare the materials. The results showed that the use of a dental adhesive significantly decreased the fluoride release of Vitremer and reduced the fluoride release of Heliomolar to undetectable levels with the methodology used. PMID:11870961

  8. Monitoring of fluoride in water samples using a smartphone.

    Science.gov (United States)

    Levin, Saurabh; Krishnan, Sunderrajan; Rajkumar, Samuel; Halery, Nischal; Balkunde, Pradeep

    2016-05-01

    In several parts of India, groundwater is the only reliable, year round source for drinking water. Prevention of fluorosis, a chronic disease resulting from excess intake of fluoride, requires the screening of all groundwater sources for fluoride in endemic areas. In this paper, the authors present a field deployable colorimetric analyzer based on an inexpensive smartphone embedded with digital camera for taking photograph of the colored solution as well as an easy-fit, and compact sample chamber (Akvo Caddisfly). Phones marketed by different smartphone makers were used. Commercially available zirconium xylenol orange reagent was used for determining fluoride concentration. A software program was developed to use with the phone for recording and analyzing the RGB color of the picture. Linear range for fluoride estimation was 0-2mgl(-1). Around 200 samples, which consisted of laboratory prepared as well as field samples collected from different locations in Karnataka, India, were tested with Akvo Caddisfly. The results showed a significant positive correlation between Ion Selective Electrode (ISE) method and Akvo Caddisfly (Phones A, B and C), with correlation coefficient ranging between 0.9952 and 1.000. In addition, there was no significant difference in the mean fluoride content values between ISE and Phone B and C except for Phone A. Thus the smartphone method is economical and suited for groundwater fluoride analysis in the field. PMID:26874766

  9. Fluoride and aluminum in teas and tea-based beverages

    Directory of Open Access Journals (Sweden)

    Hayacibara Mitsue Fujimaki

    2004-01-01

    Full Text Available OBJECTIVE: To evaluate fluoride and aluminum concentration in herbal, black, ready-to-drink, and imported teas available in Brazil considering the risks fluoride and aluminum pose to oral and general health, respectively. METHODS: One-hundred and seventy-seven samples of herbal and black tea, 11 types of imported tea and 21 samples of ready-to-drink tea were divided into four groups: I-herbal tea; II-Brazilian black tea (Camellia sinensis; III-imported tea (Camellia sinensis; IV-ready-to-drink tea-based beverages. Fluoride and aluminum were analyzed using ion-selective electrode and atomic absorption, respectively. RESULTS: Fluoride and aluminum levels in herbal teas were very low, but high amounts were found in black and ready-to-drink teas. Aluminum found in all samples analyzed can be considered safe to general health. However, considering 0.07 mg F/kg/day as the upper limit of fluoride intake with regard to undesirable dental fluorosis, some teas exceed the daily intake limit for children. CONCLUSIONS: Brazilian and imported teas made from Camellia sinensis as well as some tea-based beverages are sources of significant amounts of fluoride, and their intake may increase the risk of developing dental fluorosis.

  10. Using High Fluoride Concentration Products in Public Policy – A Rapid Review of Current Guidelines for High Fluoride Concentration products

    OpenAIRE

    Douglas, GVA; Ramsdale, M; Vinall, K.; Csikar, J

    2016-01-01

    Despite improvements in caries levels since widespread introduction of fluoride toothpastes it remains a priority in many countries around the world. Higher caries risk individuals can be targeted with products with a high fluoride concentration to help reduce the amount and severity of disease. This paper compares guidance from around the world on the use of such products and gives examples of how guidance has been translated into activity in primary care dental practice. A rapid review of e...

  11. Argon Kα measurement on DIII endash D by Ross filters technique (abstract)

    International Nuclear Information System (INIS)

    Techniques to reduce the heat flux to the divertor plates in tokamak power plants and the consequent erosion of, and subsequent damage to the divertor target plates include the injection of impurities such as argon, that can dissipate the energy (through radiative or collisional processes) before it reaches the target plates. An important issue with this type of scheme is poisoning of the plasma core by the impurities introduced in the divertor region. Subsequently, there is a desire to measure the profiles of the injected impurities in the core. X-ray Ross filters with an effective narrow band pass centered on the argon Kα line at 3.2 keV, have been installed on two of the existing x-ray arrays on DIII endash D in order to help determine the argon concentration profiles. Emissivity profiles of the Kα lines and the emissivity profiles for the argon enhanced continuum can be inferred from the inverted filtered x-ray brightness signals if Te, ne, and Ar18+ profiles are known. The MIST code is used to couple the filtered x-ray signals to the time dependent measurements of Te and ne. Further, the Ar16+ profiles measured by charge transfer spectroscopy, are used as a constraint on the MIST code runs to calculate Ar18+ profiles and unfold the argon emissivity profiles. A discussion of the Ross filters, the DIII endash D argon data, and the data analysis scheme for inferring argon emissivity profiles will be discussed. Estimates of the total argon concentration in the core determined from this technique in DIII endash D argon puff experiments will be presented. copyright 1999 American Institute of Physics

  12. High Temperature Fluoride Salt Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Richard Burns [Univ. of Tennessee, Knoxville, TN (United States); Fugate, David L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Holcomb, David Eugene [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Peretz, Fred J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Robb, Kevin R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Dane F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Yoder, Jr, Graydon L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-12-01

    Effective high-temperature thermal energy exchange and delivery at temperatures over 600°C has the potential of significant impact by reducing both the capital and operating cost of energy conversion and transport systems. It is one of the key technologies necessary for efficient hydrogen production and could potentially enhance efficiencies of high-temperature solar systems. Today, there are no standard commercially available high-performance heat transfer fluids above 600°C. High pressures associated with water and gaseous coolants (such as helium) at elevated temperatures impose limiting design conditions for the materials in most energy systems. Liquid salts offer high-temperature capabilities at low vapor pressures, good heat transport properties, and reasonable costs and are therefore leading candidate fluids for next-generation energy production. Liquid-fluoride-salt-cooled, graphite-moderated reactors, referred to as Fluoride Salt Reactors (FHRs), are specifically designed to exploit the excellent heat transfer properties of liquid fluoride salts while maximizing their thermal efficiency and minimizing cost. The FHR s outstanding heat transfer properties, combined with its fully passive safety, make this reactor the most technologically desirable nuclear power reactor class for next-generation energy production. Multiple FHR designs are presently being considered. These range from the Pebble Bed Advanced High Temperature Reactor (PB-AHTR) [1] design originally developed by UC-Berkeley to the Small Advanced High-Temperature Reactor (SmAHTR) and the large scale FHR both being developed at ORNL [2]. The value of high-temperature, molten-salt-cooled reactors is also recognized internationally, and Czechoslovakia, France, India, and China all have salt-cooled reactor development under way. The liquid salt experiment presently being developed uses the PB-AHTR as its focus. One core design of the PB-AHTR features multiple 20 cm diameter, 3.2 m long fuel channels

  13. Wetting and evaporation of argon nanodroplets on smooth and rough substrates: Molecular dynamics simulations

    Science.gov (United States)

    Li, Qun; Wang, Baohe; Chen, Yonggang; Zhao, Zongchang

    2016-10-01

    Wetting and evaporation behaviors of argon nanodroplets on smooth and rough substrates are studied using molecular dynamics simulations. Effects of interaction energy between solid and argon atoms on wetting and evaporation and differences between nanodroplets on smooth and rough substrates have been investigated. The results show that for both smooth and rough substrates, as the interaction energy between solid and argon atoms increases, the contact angle and total evaporation increase. For rough substrates, the variations of contact angle and contact radius during evaporation progress are much more complex and the total evaporation is much larger than that of smooth substrates.

  14. A Study of Dielectric Breakdown Along Insulators Surrounding Conductors in Liquid Argon

    CERN Document Server

    Lockwitz, Sarah

    2015-01-01

    High voltage breakdown in liquid argon is an important consideration in the design of liquid argon time projection chambers, which are often used as neutrino and dark matter detectors. We have made systematic measurements of breakdown voltages in liquid argon along insulators surrounding negative rod electrodes. The purpose of these tests is to understand the effects of materials, of breakdown path length, and of surface topology. We have found no material-specific effects other than those due to their permittivity. We have found no dependence on breakdown voltage on the length of the exposed insulator. A model for the breakdown mechanism is presented that can help inform future designs.

  15. Design Principles and Operational Results of the Cryogenic System for the ATLAS Liquid Argon Calorimeter

    CERN Document Server

    Fabre, C; Chalifour, M; Gonidec, G; Passardi, Giorgio; Petit, P; Pezzetti, M; Wicek, F

    2009-01-01

    The ATLAS liquid argon calorimeter housed in three independent cryostats containing a total argon volume of about 78 m3 has been installed in the underground cavern. The three detectors have been cooled down following stringent temperature gradient limits and have been filled with liquid argon. The cryostats are now in a stable condition for periods going up to almost two years. The temperature uniformity within each of the three detector volumes is found to be within 70 mK rms, while the temperature stability stays below 5 mK rms.

  16. A new ozone standard - The vapor pressure of ozone at liquid argon temperatures

    Science.gov (United States)

    Mauersberger, K.; Hanson, D.; Morton, J.

    1985-01-01

    The vapor pressure of ozone has been measured at liquid argon temperatures. At the normal boiling point of argon (-185.9 C) an ozone pressure of 0.0405 torr was obtained with an accuracy of + or - 1.5 percent. Increases and decreases in liquid argon temperatures raised and lowered the ozone vapor pressure, respectively. During the vapor pressure measurements the purity of ozone was monitored with a mass spectrometer. The proposed ozone standard will considerably improve the calibration of experiments for atmospheric research, the determination of absorption cross sections and other laboratory ozone studies.

  17. Surface compositional changes in GaAs subjected to argon plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Surdu-Bob, C.C.; Sullivan, J.L.; Saied, S.O.; Layberry, R.; Aflori, M

    2002-12-30

    X-ray photoelectron spectroscopy (XPS) has been employed to study surface compositional changes in GaAs (1 0 0) subjected to argon plasma treatment. The experimental results have been explained in terms of predicted argon ion energies, measured ion densities and etch rates. A model is proposed for the processes taking place at the surface of GaAs in terms of segregation, sputtering and surface relaxation. Stopping and range of ions in matter (SRIM) code has also been employedan aid to identification of the mechanisms responsible for the compositional changes. Argon plasma treatment induced surface oxidation at very low energies and sputtering and surface damage with increasing energy.

  18. Changes in a surface of polycrystalline aluminum upon bombardment with argon ions

    Science.gov (United States)

    Ashkhotov, O. G.; Ashkhotova, I. B.; Bliev, A. P.; Magkoev, T. T.; Krymshokalova, D. A.

    2014-10-01

    The interaction between argon ions and a natural oxide layer of polycrystalline aluminum is studied via Auger electron (AE) and electron energy loss (EEL) spectroscopy. It is found that bombardment with argon ions whose energy is lower than the Al2O3 sputtering threshold results in the accumulation of bombarding ions in interstitial surface voids, thus forming a supersaturated solid solution of target atoms and bombarding ions of argon and nitrogen entrapped by the ion beam from the residual gas of the working chamber of the spectrometer.

  19. Kinetic modelling of krypton fluoride laser systems

    International Nuclear Information System (INIS)

    A kinetic model has been developed for the KrF* rare gas halide laser system, specifically for electron-beam pumped mixtures of krypton, fluorine, and either helium or argon. The excitation produced in the laser gas by the e-beam was calculated numerically using an algorithm checked by comparing the predicted ionization yields in the pure rare gases with their experimental values. The excitation of the laser media by multi-kilovolt x-rays was also modeled and shown to be similar to that produced by high energy electrons. A system of equations describing the transfer of the initial gas excitation into the laser upper level was assembled using reaction rate constants from both experiment and theory. A one-dimensional treatment of the interaction of the laser radiation with the gas was formulated which considered spontaneous and stimulated emission and absorption. The predictions of this model were in good agreement with the fluorescence signals and gain and absorption measured experimentally

  20. Kinetic modelling of krypton fluoride laser systems

    Energy Technology Data Exchange (ETDEWEB)

    Jancaitis, K.S.

    1983-11-01

    A kinetic model has been developed for the KrF* rare gas halide laser system, specifically for electron-beam pumped mixtures of krypton, fluorine, and either helium or argon. The excitation produced in the laser gas by the e-beam was calculated numerically using an algorithm checked by comparing the predicted ionization yields in the pure rare gases with their experimental values. The excitation of the laser media by multi-kilovolt x-rays was also modeled and shown to be similar to that produced by high energy electrons. A system of equations describing the transfer of the initial gas excitation into the laser upper level was assembled using reaction rate constants from both experiment and theory. A one-dimensional treatment of the interaction of the laser radiation with the gas was formulated which considered spontaneous and stimulated emission and absorption. The predictions of this model were in good agreement with the fluorescence signals and gain and absorption measured experimentally.

  1. Profile of Fluoride Release from a Nanohybrid Composite Resin

    Directory of Open Access Journals (Sweden)

    Raquel Assed Bezerra Silva

    2015-02-01

    Full Text Available The aim of this study was to evaluate in vitro the amount and profile of fluoride release from a fluoride-containing nanohybrid composite resin (Tetric® N-Ceram by direct potentiometry. Thirty specimens (5 mm diameter x 3 mm high; n=10/material were made of Tetric® N-Ceram, Vitremer® resin-modified glass ionomer cement (RMGIC (positive control or Filtek® Z350 nanofill composite resin (negative control. The specimens were stored individually in plastic tubes containing 1 mL of artificial saliva at 37°C, which was daily renewed during 15 days. At each renewal of saliva, the amount of fluoride ions released in the solution was measured using a fluoride ion-selective electrode with ion analyzer, and the values obtained in mV were converted to ppm (µg/mL. Data were analyzed statistically by ANOVA and Tukey’s post-hoc test at a significance level of 5%. The results showed that the resins Tetric® N-Ceram and Filtek® Z350 did not release significant amounts of fluoride during the whole period of evaluation (p>0.05. Only Vitremer® released significant amounts of fluoride ions during the 15 days of the experiment, with greater release in first 2 days (p0.05. In conclusion, the nanohybrid composite resin Tetric® N-Ceram did not present in vitro fluoride-releasing capacity throughout the 15 days of study.

  2. Compression of lithium fluoride to 92 GPa

    Science.gov (United States)

    Dong, Haini; Dorfman, Susannah M.; Holl, Christopher M.; Meng, Yue; Prakapenka, Vitali B.; He, Duanwei; Duffy, Thomas S.

    2014-01-01

    The equation of state and compression behavior of lithium fluoride, LiF, have been determined to 92 GPa by X-ray diffraction in a diamond anvil cell. A neon pressure-transmitting medium was used to minimize the effect of differential stress on the sample. Consistent results using multiple pressure standards were obtained. By fitting the pressure-volume data to a Birch-Murnaghan equation of state, the isothermal bulk modulus and its corresponding pressure derivative at zero pressure were determined to be K0=70.1±0.7 GPa, and K‧0=4.3±0.1. If the bulk modulus is fixed at 66.2 GPa, a value well constrained by independent elasticity measurements, we obtain K‧0=4.6±0.1. The bulk modulus and its pressure derivative obtained from this work resolve the large discrepancy in previously reported values of K0 and K‧0 for this material. Consequently, the equation of state of LiF is now sufficiently well constrained to allow its use as a pressure calibrant in high pressure experiments.

  3. Characterization of cerium fluoride nanocomposite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Stange, Sy [Los Alamos National Laboratory; Esch, Ernst I [Los Alamos National Laboratory; Brown, Leif O [Los Alamos National Laboratory; Couture, Aaron J [Los Alamos National Laboratory; Mckigney, Edward A [Los Alamos National Laboratory; Muenchausen, Ross E [Los Alamos National Laboratory; Del Sesto, Rico E [Los Alamos National Laboratory; Gilbertson, Robert D [Los Alamos National Laboratory; Mccleskey, T Mark [Los Alamos National Laboratory; Reifarth, Rene [Los Alamos National Laboratory

    2009-01-01

    Measurement of the neutron capture cross-sections of a number of short-lived isotopes would advance both pure and applied scientific research. These cross-sections are needed for calculation of criticality and waste production estimates for the Advanced Fuel Cycle Initiative, for analysis of data from nuclear weapons tests, and to improve understanding of nucleosynthesis. However, measurement of these cross-sections would require a detector with a faster signal decay time than those used in existing neutron capture experiments. Crystals of faster detector materials are not available in sufficient sizes and quantities to supply these large-scale experiments. Instead, we propose to use nanocomposite detectors, consisting of nanoscale particles of a scintillating material dispersed in a matrix material. We have successfully fabricated cerium fluoride (CeF{sub 3}) nanoparticles and dispersed them in a liquid matrix. We have characterized this scintillator and have measured its response to neutron capture. Results of the optical, structural, and radiation characterization will be presented.

  4. Magnetic separation of uranium from magnesium fluoride

    International Nuclear Information System (INIS)

    The attraction or repulsion of particles by a magnetic gradient, based on the respective susceptibilities, provides the basis for physical separation of particles that are comprised predominantly of uranium from those that are predominantly magnesium fluoride (MgF2). To determine the effectiveness of this approach, a bench-scale magnetic separator from the S.G. Frantz Co., Inc. was used. In the Frantz Model L-1, particles are fed through a funnel onto a vibration tray and through a magnetic field. The specific design of the Frantz magnet causes the magnetic field strength to vary along the width of the magnet, setting up a gradient. The tray in the magnetic field is split at a point about half way down its length so that the separated material does not recombine. A schematic is presented of Frantz Model L-1 CN - the same magnet configured for high gradient magnetic separation of liquid-suspended particles. Here different pole pieces create a uniform magnetic field, and stainless steel wood in the canister between the pole pieces creates the high gradient. 1 ref., 6 figs., 2 tabs

  5. Characterization of cerium fluoride nanocomposite scintillators

    International Nuclear Information System (INIS)

    Measurement of the neutron capture cross-sections of a number of short-lived isotopes would advance both pure and applied scientific research. These cross-sections are needed for calculation of criticality and waste production estimates for the Advanced Fuel Cycle Initiative, for analysis of data from nuclear weapons tests, and to improve understanding of nucleosynthesis. However, measurement of these cross-sections would require a detector with a faster signal decay time than those used in existing neutron capture experiments. Crystals of faster detector materials are not available in sufficient sizes and quantities to supply these large-scale experiments. Instead, we propose to use nanocomposite detectors, consisting of nanoscale particles of a scintillating material dispersed in a matrix material. We have successfully fabricated cerium fluoride (CeF3) nanoparticles and dispersed them in a liquid matrix. We have characterized this scintillator and have measured its response to neutron capture. Results of the optical, structural, and radiation characterization will be presented.

  6. In vivo and in vitro studies of a cetylamine fluoride mouthrinse: evaluation of a device used for in vitro experiments

    Directory of Open Access Journals (Sweden)

    CARVALHO Sílvia Magaly Sasso

    1999-01-01

    Full Text Available A mouthrinse containing cetylamine fluoride (230 ppm in fluoride was prepared for in vitro studies of fluoride clearance and adsorption by enamel and/or hydroxyapatite using a device that simulates the oral cavity. In vivo studies of fluoride clearance from this mouthrinse were conducted and compared with other fluoride sources. The amount of fluoride adsorbed to tooth blocks or powdered hydroxyapatite, both treated with this cetylamine fluoride mouthrinse once or twice a day, was determined. The results of these studies showed that it is possible to prepare a mouthrinse with cetylamine fluoride for alternative use by patients for the prevention and therapy of dental caries.

  7. Self-assembled heterogeneous argon/neon core-shell clusters studied by photoelectron spectroscopy.

    Science.gov (United States)

    Lundwall, M; Pokapanich, W; Bergersen, H; Lindblad, A; Rander, T; Ohrwall, G; Tchaplyguine, M; Barth, S; Hergenhahn, U; Svensson, S; Björneholm, O

    2007-06-01

    Clusters formed by a coexpansion process of argon and neon have been studied using synchrotron radiation. Electrons from interatomic Coulombic decay as well as ultraviolet and x-ray photoelectron spectroscopy were used to determine the heterogeneous nature of the clusters and the cluster structure. Binary clusters of argon and neon produced by coexpansion are shown to exhibit a core-shell structure placing argon in the core and neon in the outer shells. Furthermore, the authors show that 2 ML of neon on the argon core is sufficient for neon valence band formation resembling the neon solid. For 1 ML of neon the authors observe a bandwidth narrowing to about half of the bulk value.

  8. Surface modification of polypropylene using argon plasma: Statistical optimization of the process variables

    International Nuclear Information System (INIS)

    Low pressure plasma treatment using radiofrequency (rf) discharge of argon gas was employed to improve the hydrophilicity of polypropylene. The effects of argon plasma on the wettability, surface chemistry and surface morphology of polypropylene were studied using static contact angle measurements, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Increase in surface energy of polypropylene was observed as a result of argon plasma treatment. SEM and AFM images revealed the increased surface roughness. A set of identified process variables (rf power, pressure, argon flow rate and time) were used in this study and were optimized using central composite design (CCD) of response surface methodology (RSM). A statistical model was developed to represent the surface energy in terms of the process variables mentioned above. Accuracy of the model was verified and found to be high.

  9. Simulations of argon accident scenarios in the ATLAS experimental cavern a safety analysis

    CERN Document Server

    Balda, F

    2002-01-01

    Some characteristic accidents in the ATLAS experimental cavern (UX15) are simulated by means of STAR-CD, a code using the "Finite-Volume" method. These accidents involve different liquid argon leaks from the barrel cryostat of the detector, thus causing the dispersion of the argon into the Muon Chamber region and the evaporation of the liquid. The subsequent temperature gradients and distribution of argon concentrations, as well as their evolution in time are simulated and discussed, with the purpose of analysing the dangers related to asphyxiation and to contact with cryogenic fluids for the working personnel. A summary of the theory that stands behind the code is also given. In order to validate the models, an experimental test on a liquid argon spill performed earlier is simulated, showing that the program is able to output reliable results. At the end, some safety-related recommendations are listed.

  10. Pose Measurement Performance of the Argon Relative Navigation Sensor Suite in Simulated Flight Conditions

    Science.gov (United States)

    Galante, Joseph M.; Eepoel, John Van; Strube, Matt; Gill, Nat; Gonzalez, Marcelo; Hyslop, Andrew; Patrick, Bryan

    2012-01-01

    Argon is a flight-ready sensor suite with two visual cameras, a flash LIDAR, an on- board flight computer, and associated electronics. Argon was designed to provide sensing capabilities for relative navigation during proximity, rendezvous, and docking operations between spacecraft. A rigorous ground test campaign assessed the performance capability of the Argon navigation suite to measure the relative pose of high-fidelity satellite mock-ups during a variety of simulated rendezvous and proximity maneuvers facilitated by robot manipulators in a variety of lighting conditions representative of the orbital environment. A brief description of the Argon suite and test setup are given as well as an analysis of the performance of the system in simulated proximity and rendezvous operations.

  11. Formation and characterization of magnesium bisozonide and carbonyl complexes in solid argon.

    Science.gov (United States)

    Wang, Guanjun; Gong, Yu; Zhang, Qingqing; Zhou, Mingfei

    2010-10-14

    The reactions of magnesium atoms with dioxygen and dioxygen/carbon monoxide mixture have been investigated by matrix isolation infrared absorption spectroscopy. Magnesium atoms react with dioxygen in solid argon to form the inserted MgO(2) molecules under UV excitation, which were previously characterized. Annealing allows the dioxygen molecules to diffuse and to react with MgO(2) and form the magnesium bisozonide complex, Mg(O(3))(2), which is proposed to be coordinated by two argon atoms in solid argon matrix. The Mg(O(3))(2)(Ar)(2) complex is characterized to have two equivalent side-on bonded ozonide ligands with a D(2h) symmetry. The coordinated argon atoms can be replaced by carbon monoxide to give the magnesium bisozonide dicarbonyl complex, Mg(O(3))(2)(CO)(2), a neutral magnesium carbonyl complex with CO binding to the Mg(2+) center. PMID:20857987

  12. Dynamic range compression in a liquid argon calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Cleland, W.E. [Univ. of Pittsburgh, PA (United States); Lissauer, D.; Radeka, V.; Rescia, S.; Takai, H. [Brookhaven National Lab., Upton, NY (United States); Wingerter-Seez, I. [LAPP, Annecy-le-Vieux (France)

    1996-12-31

    The anticipated range of particle energies at the LHC, coupled with the need for precision, low noise calorimetry makes severe demands on the dynamic range of the calorimeter readout. A common approach to this problem is to use shapers with two or more gain scales. In this paper, the authors describe their experience with a new approach in which a preamplifier with dynamic gain compression is used. An unavoidable consequence of dynamic gain adjustment is that the peaking time of the shaper output signal becomes amplitude dependent. The authors have carried out a test of such a readout system in the RD3 calorimeter, a liquid argon device with accordion geometry. The calibration system is used to determine both the gain of the individual channels as well as to map the shape of the waveform as a function of signal amplitude. A new procedure for waveform analysis, in which the fitted parameters describe the impulse response of the system, permits a straightforward translation of the calibration waveform to the waveform generated by a particle crossing the ionization gap. They find that the linearity and resolution of the calorimeter is equivalent to that obtained with linear preamplifiers, up to an energy of 200 GeV.

  13. Coherent set of electron cross sections for argon

    Science.gov (United States)

    Alves, L. L.; Ferreira, C. M.

    2011-10-01

    This paper presents a coherent set of electron impact cross sections for argon (elastic momentum-transfer, inelastic for the excitation of 37 levels Ar(4s,4p,3d,5p,4d,6s) and ionization), which was recently uploaded onto the LXcat IST-Lisbon database. The cross section set was validated by comparing calculated swarm parameters (electron mobility and characteristic energy) and rate coefficients (Townsend ionization coefficient and direct + cascade excitation coefficients to the 4s and 4p states) with available experimental data, for E / N = 10-4 - 100 Td and Tg = 300, 77 K. The validation procedure involves the solution to the homogeneous two-term electron Boltzmann equation, resorting to three different solvers: (i) IST-Lisbon's (ii) BOLSIG+ (v1.2) with LXcat; (iii) BOLSIG+ (v1.23). The results obtained with these solvers are compared to evidence the importance of certain numerical features related with both the energy-grid (number of points, grid-type and maximum energy value) and the interpolation scheme adopted for the cross sections. In particular, the latter can cause a 6% variation on the values of swarm parameters at intermediate E/Ns.

  14. An update of argon inelastic cross sections for plasma discharges

    International Nuclear Information System (INIS)

    This paper proposes a coherent set of electron impact inelastic cross sections for argon, based on recent experimental measurements. The updated set is validated by comparing calculated swarm parameters and rate coefficients (obtained by solving the two-term approximation electron Boltzmann equation) with available experimental data. This validation procedure is usually adopted when the cross section set is to be later used in plasma discharge modelling. Simulation results for the electron drift velocity and characteristic energy are in very good agreement with experimental values of these quantities. Calculations, using cross section sets proposed by different authors, of the total (direct + cascade) excitation coefficients to the 4s and 4p states, and of the Townsend ionization coefficient, show that the present set ensures the best overall agreement with measured values. The agreement is particularly good for the excitation coefficient to metastable 4s'[1/2]0 and the Townsend ionization coefficient, which are probably the most relevant electron macroscopic coefficients in the modelling of discharge plasmas

  15. Argon defect complexes in low energy Ar irradiated molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    van Veen, A.; Buters, W.T.M.; van der Kolk, G.J.; Caspers, L.M. (Interuniversitair Reactor Instituut, Delft (Netherlands)); Armstrong, T.R. (Victoria Univ., Wellington (New Zealand). Dept. of Physics)

    1982-03-15

    Thermal desorption spectrometry has been used to study the defects created in Mo irradiated along the <110> direction with Ar ions ranging in energy from 0.1 to 2 keV. In addition to monitoring the release of the implanted Ar, additional information has been obtained by decoration of the defects with low energy helium and subsequent monitoring of the helium release. The studies show evidence that the Ar can be trapped in both substitutional sites and in a configuration in which the Ar is associated with vacancies (ArVsub(n), n >= 2). Most of the Ar implanted at high energy is released at approx. equal to 1500 K by thermal vacancy assisted diffusion. Argon trapped closer to the surface is released at lower temperatures via at least three different surface related release mechanisms. Additional results are presented on the interaction of self interstitial atoms (introduced by 100 eV Xe bombardment) with the Ar defects. Substitutional Ar is found to convert to interstitial Ar which seems to be mobile at room temperature. The Ar-vacancy complexes are found to be reduced to substitutional Ar. The results of atomistic calculations of the release mechanisms will also be presented.

  16. Scintillation Light from Cosmic-Ray Muons in Liquid Argon

    CERN Document Server

    Whittington, Denver

    2014-01-01

    This paper reports the results of the first experiment to directly measure the properties of the scintillation light generated by minimum ionizing cosmic-ray muons in liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches, as well as for particle identification. The experiment was carried out at the TallBo facility at Fermilab using prototype light guides and electronics developed for the Long-Baseline Neutrino Experiment. Analysis of the time-resolved structure of the scintillation light from cosmic-ray muons gives $\\langle \\tau_{\\text{T}}\\rangle = 1.43 \\pm 0.04~\\text{(stat.)} \\pm 0.007~\\text{(sys.)}~\\mu$s for the triplet light decay time constant. The ratio of singlet to triplet light measured using surface-coated light guides is $R = 0.39 \\pm 0.01~\\text{(stat.)} \\pm 0.008~\\text{(sys.)}$. There is some evidence that this value is not consistent with $R$ for minimum ionizing electrons. However, the value for $...

  17. State-selective radiative recombination cross sections of argon ions

    International Nuclear Information System (INIS)

    The n-, (n,l)- and fine-structure level state-selective radiative recombinations (RR) cross sections of argon ions Ar18+,Ar13+,Ar7+ and Ar+ are obtained with the semi-classical Kramer formula, the relativistic self-consistent field (RSCF) method and the relativistic configuration interaction (RCI) method. It is found that for the highly charged ions with few electrons, the cross sections calculated with these three methods are in good agreement with each other. But as the number of electrons increases, the Kramer formula deviates from the RSCF and RCI results. For instance, when the energy of the incident electron is larger than 100 eV, the n-state selective cross sections of Ar7+ calculated from the Kramer formula are underestimated for more than 50%. The RSCF results are in general agreement with the RCI results. However, for the low charged ions, a clear distinction appears due to the strong configuration interaction, especially near the Cooper minimum. The n-resolved (n≤10) and total Maxwellian averaged rate coefficients are calculated, and the analytic fitting parameters are also provided. -- Highlights: ► The RR cross sections of Ar18+, Ar13+, Ar7+ and Ar+ are obtained. ► The Kramer formula, the relativistic self-consistent field and RCI methods are used. ► Results from three methods are compared with each other.

  18. Electronics calibration board for the ATLAS liquid argon calorimeters

    International Nuclear Information System (INIS)

    To calibrate the energy response of the ATLAS liquid argon calorimeter, an electronics calibration board has been designed; it delivers a signal whose shape is close to the calorimeter ionization current signal with amplitude up to 100 mA in 50 Ω with 16 bit dynamic range. The amplitude of this signal is designed to be uniform over all calorimeters channels, stable in time and with an integral linearity much better that the electronics readout. The various R and D phases and most of the difficulties met are discussed and illustrated by many measurements. The custom design circuits are described and the layout of the ATLAS calibration board presented. The procedure used to qualify the boards is explained and the performance obtained illustrated: a dynamic range up to 3 TeV in three energy scales with an integral linearity better than 0.1% in each of them, a response uniformity better than 0.2% and a stability better than 0.1%. The performance of the board is well within the ATLAS requirements. Finally, in situ measurements done on the ATLAS calorimeter are shown to validate these performances

  19. Methane from benzene in argon dielectric barrier discharge

    International Nuclear Information System (INIS)

    Highlights: ► Efficient on-line conversion of benzene to methane at room temperature. ► Absence of other H-atom donor suggests new type of chemistry. ► For parent loss > 90%, methane yield was ∼40% of limit due to H-atom availability. ► Surface moisture contributed ·OH radical for trace phenolic products’ formation. ► This method may emerge as an exploitable tactic for pollutants’ usable alterations. -- Abstract: A first-time account of direct, on-line, instantaneous and efficient chemical conversion of gas phase benzene to methane in argon Dielectric Barrier Discharge (DBD) is presented. In the absence of another overt hydrogen-donating source, potency of analogous parents toward methane generation is found to follow the order: benzene > toluene > p-xylene. Simultaneous production of trace amounts of phenolic surface deposits suggest (a) prompt decomposition of the parent molecules, including a large fraction yielding atomic transients (H-atom), (b) continuous and appropriate recombination of such parts, and (c) trace moisture in parent contributing ·OH radicals and additional H-atoms, which suitably react with the unreacted fraction of the parent, and also other intermediates. Results highlight Ar DBD to be a simple and exploitable technology for transforming undesirable hazardous aromatics to usable/useful low molecular weight open-chain products following the principles of green chemistry and engineering

  20. Stabilization of fluoroindate glasses by magnesium fluoride and other heavy metal fluorides

    Directory of Open Access Journals (Sweden)

    B. J. Costa

    1998-06-01

    Full Text Available Their extended transparency in the IR makes them attractive for use as optical fibers for CO laser power delivery and optical amplification. This paper firstly describes the spectacular stabilizing effect of MgF2 on the binary system InF3-BaF2. The investigation of the InF3-BaF2-MgF2 system led to samples up to 5mm in thickness. Further optimization of this system was achieved by incorporation of limited amounts of other fluorides and resulted in increased resistence to devitrification. The second approach of this work was concerned to the investigation of the pseudo-ternary system InF3-GdF3-GaF3 at constant concentrations of ZnF2-SrF2-BaF2-NaF. Several compositions were studied in this system. The samples presented a better thermal stability when compared to other families of fluoride glasses. Therefore, these glasses seem to be very promising for the fabrication of special optical fibers. Thermal data are reported.

  1. An Overview of Liquid Fluoride Salt Heat Transport Systems

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David Eugene [ORNL; Cetiner, Sacit M [ORNL

    2010-09-01

    Heat transport is central to all thermal-based forms of electricity generation. The ever increasing demand for higher thermal efficiency necessitates power generation cycles transitioning to progressively higher temperatures. Similarly, the desire to provide direct thermal coupling between heat sources and higher temperature chemical processes provides the underlying incentive to move toward higher temperature heat transfer loops. As the system temperature rises, the available materials and technology choices become progressively more limited. Superficially, fluoride salts at {approx}700 C resemble water at room temperature being optically transparent and having similar heat capacity, roughly three times the viscosity, and about twice the density. Fluoride salts are a leading candidate heat-transport material at high temperatures. Fluoride salts have been extensively used in specialized industrial processes for decades, yet they have not entered widespread deployment for general heat transport purposes. This report does not provide an exhaustive screening of potential heat transfer media and other high temperature liquids such as alkali metal carbonate eutectics or chloride salts may have economic or technological advantages. A particular advantage of fluoride salts is that the technology for their use is relatively mature as they were extensively studied during the 1940s-1970s as part of the U.S. Atomic Energy Commission's program to develop molten salt reactors (MSRs). However, the instrumentation, components, and practices for use of fluoride salts are not yet developed sufficiently for commercial implementation. This report provides an overview of the current understanding of the technologies involved in liquid salt heat transport (LSHT) along with providing references to the more detailed primary information resources. Much of the information presented here derives from the earlier MSR program. However, technology has evolved over the intervening years

  2. Optically Forbidden Excitations of 3s Electron of Argon by Fast Electron Impact

    Institute of Scientific and Technical Information of China (English)

    朱林繁; 成华东; 刘小井; 田鹏; 苑震生; 李文斌; 徐克尊

    2003-01-01

    The electron energy loss spectrum of argon in the energy region of 24.5-30.5eV was measured at 2.5 keV impact energy. The line profile parameters of the optically forbidden excitations of 3s-1ns (n = 4-6) and 3s-1nd (n = 3-7) of argon, I.e.,Eγ,Г,q and p,were determined.

  3. Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    OpenAIRE

    Baptista, B.; Bugel, L.; Chiu, C; Conrad, J. M.; Ignarra, C. M.; Jones, B. J. P.; Katori, T.; Mufson, S.

    2012-01-01

    Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UV...

  4. TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    CERN Document Server

    Ignarra, C M

    2013-01-01

    Light detection systems in Liquid Argon Time Projection Chambers (LArTPCs) require the detection of the 128 nm light produced during argon scintillation. Most detectors use Tetraphenyl Butadiene (TPB) to shift the wavelength of the light into a range visible to Photomultiplier Tubes (PMTs). These proceedings summarize characterizations of light-guides coated with a matrix of TPB in UV transmitting acrylic which are more compact than existing LArTPC light collection systems.

  5. TPB-coated light guides for liquid argon TPC light detection systems

    Science.gov (United States)

    Ignarra, C. M.

    2013-10-01

    Light detection systems in Liquid Argon Time Projection Chambers (LArTPCs) require the detection of the 128 nm light produced during argon scintillation. Most detectors use Tetraphenyl Butadiene (TPB) to shift the wavelength of the light into a range visible to Photomultiplier Tubes (PMTs). These proceedings summarize characterizations of light-guides coated with a matrix of TPB in UV transmitting acrylic which are more compact than existing LArTPC light collection systems.

  6. Effect of Ginkgo biloba on the lesions induced by retinal argon laser photocoagulation in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Clairambault, P.; Pairault, C.; Droy-Lefaix, M.T.; Magnier, B.; Magnier, M.

    1986-01-09

    In rabbits, retinal argon laser photocoagulation disrupts the arrangement of cell layers and produces interstitial edema. Photochemical and thermal energy is released with production of free oxygenated radicals that are responsible for destruction of cell membranes. Retinal argon laser photocoagulation in rabbits was used as a pharmacologic model to evaluate the protective effect of EGB 761 against membrane lesions and edema. As a strong free radicals scavengers, EGB 761 confirms its protective action on cells membranes and its anti-edema effect.

  7. Configurational Entropy,Diffusivity and Potential Energy Landscape in Liquid Argon

    Institute of Scientific and Technical Information of China (English)

    DUAN Yong-Ping; MA Cong-Xiao; LI Jia-Yun; LI Cong; WANG Dan; LI Mei-Li; SUN Min-Hua

    2009-01-01

    The configurational entropy, diffusion coefficient, dynamics and thermodynamics fragility indices of liquid argon are calculated using molecular dynamics simulations at two densities. The relationship between dynamics and thermodynamics properties is studied. The diffusion coefficient depends linearly on configurational entropy, which is consistent with the hypothesis of Adam-Gibbs. The consistence of dynamics and thermodynamics fragility indices demonstrates that dynamical behaviour is governed by thermodynamics behaviour in glass transition of liquid argon.

  8. Effect of Ginkgo biloba on the lesions induced by retinal argon laser photocoagulation in rabbits

    International Nuclear Information System (INIS)

    In rabbits, retinal argon laser photocoagulation disrupts the arrangement of cell layers and produces interstitial edema. Photochemical and thermal energy is released with production of free oxygenated radicals that are responsible for destruction of cell membranes. Retinal argon laser photocoagulation in rabbits was used as a pharmacologic model to evaluate the protective effect of EGB 761 against membrane lesions and edema. As a strong free radicals scavengers, EGB 761 confirms its protective action on cells membranes and its anti-edema effect

  9. A correction to Birks' Law in liquid argon ionization chamber simulations for highly ionizing particles

    International Nuclear Information System (INIS)

    We present a study of the performance of Birks' Law in liquid argon ionization chamber simulations as applied to highly ionizing particles, such as particles with multiple electric charges or with magnetic charge. We used Birks' Law to model recombination effects in a GEANT4 simulation of heavy ions in a liquid argon calorimeter. We then compared the simulation to published heavy-ion data to extract a highly ionizing particle correction to Birks' Law.

  10. LArGe: Background suppression using liquid argon (LAr) scintillation for 0$\

    CERN Document Server

    Marco, M D; Schönert, S

    2007-01-01

    Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\\pi$ anti-Compton spectrometer to suppress backgrounds in the HPGe. This R&D is carried out in the framework of the GERDA experiment which searches for 0$\

  11. Recommendations for fluoride limits in drinking water based on estimated daily fluoride intake in the Upper East Region, Ghana.

    Science.gov (United States)

    Craig, Laura; Lutz, Alexandra; Berry, Kate A; Yang, Wei

    2015-11-01

    Both dental and skeletal fluorosis caused by high fluoride intake are serious public health concerns around the world. Fluorosis is particularly pronounced in developing countries where elevated concentrations of naturally occurring fluoride are present in the drinking water, which is the primary route of exposure. The World Health Organization recommended limit of fluoride in drinking water is 1.5 mg F(-) L(-1), which is also the upper limit for fluoride in drinking water for several other countries such as Canada, China, India, Australia, and the European Union. In the United States the enforceable limit is much higher at 4 mg F(-) L(-1), which is intended to prevent severe skeletal fluorosis but does not protect against dental fluorosis. Many countries, including the United States, also have notably lower unenforced recommended limits to protect against dental fluorosis. One consideration in determining the optimum fluoride concentration in drinking water is daily water intake, which can be high in hot climates such as in northern Ghana. The results of this study show that average water intake is about two times higher in Ghana than in more temperate climates and, as a result, the fluoride intake is higher. The results also indicate that to protect the Ghanaian population against dental fluorosis, the maximum concentration of fluoride in drinking water for children under 6-8 years should be 0.6 mg F(-) L(-1) (and lower in the first two years of life), and the limit for older children and adults should be 1.0 mg F(-) L(-1). However, when considering that water treatment is not cost-free, the most widely recommended limit of 1.5 mg F(-) L(-1) - which is currently the limit in Ghana--may be appropriate for older children and adults since they are not vulnerable to dental fluorosis once the tooth enamel is formed.

  12. Recommendations for fluoride limits in drinking water based on estimated daily fluoride intake in the Upper East Region, Ghana.

    Science.gov (United States)

    Craig, Laura; Lutz, Alexandra; Berry, Kate A; Yang, Wei

    2015-11-01

    Both dental and skeletal fluorosis caused by high fluoride intake are serious public health concerns around the world. Fluorosis is particularly pronounced in developing countries where elevated concentrations of naturally occurring fluoride are present in the drinking water, which is the primary route of exposure. The World Health Organization recommended limit of fluoride in drinking water is 1.5 mg F(-) L(-1), which is also the upper limit for fluoride in drinking water for several other countries such as Canada, China, India, Australia, and the European Union. In the United States the enforceable limit is much higher at 4 mg F(-) L(-1), which is intended to prevent severe skeletal fluorosis but does not protect against dental fluorosis. Many countries, including the United States, also have notably lower unenforced recommended limits to protect against dental fluorosis. One consideration in determining the optimum fluoride concentration in drinking water is daily water intake, which can be high in hot climates such as in northern Ghana. The results of this study show that average water intake is about two times higher in Ghana than in more temperate climates and, as a result, the fluoride intake is higher. The results also indicate that to protect the Ghanaian population against dental fluorosis, the maximum concentration of fluoride in drinking water for children under 6-8 years should be 0.6 mg F(-) L(-1) (and lower in the first two years of life), and the limit for older children and adults should be 1.0 mg F(-) L(-1). However, when considering that water treatment is not cost-free, the most widely recommended limit of 1.5 mg F(-) L(-1) - which is currently the limit in Ghana--may be appropriate for older children and adults since they are not vulnerable to dental fluorosis once the tooth enamel is formed. PMID:26058000

  13. Aquaporin 5 Interacts with Fluoride and Possibly Protects against Caries.

    Directory of Open Access Journals (Sweden)

    Ida Anjomshoaa

    Full Text Available Aquaporins (AQP are water channel proteins and the genes coding for AQP2, AQP5, and AQP6 are clustered in 12q13. Since AQP5 is expressed in serous acinar cells of salivary glands, we investigated its involvement in caries. DNA samples from 1,383 individuals from six groups were studied. Genotypes of eight single nucleotide polymorphisms covering the aquaporin locus were tested for association with caries experience. Interaction with genes involved in enamel formation was tested. The association between enamel microhardness at baseline, after creation of artificial caries lesion, and after exposure to fluoride and the genetic markers in AQP5 was tested. Finally, AQP5 expression in human whole saliva, after exposure to fluoride in a mammary gland cell line, which is known to express AQP5, and in Wistar rats was also verified. Nominal associations were found between caries experience and markers in the AQP5 locus. Since these associations suggested that AQP5 may be inhibited by levels of fluoride in the drinking water that cause fluorosis, we showed that fluoride levels above optimal levels change AQP5 expression in humans, cell lines, and rats. We have shown that AQP5 is involved in the pathogenesis of caries and likely interacts with fluoride.

  14. Improved fluoride volatility reprocessing for MOX fuel cycle

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, M.; Fukasawa, T.; Sawa, T.; Yamashita, J.; Kamoshida, M.; Sasahira, A.; Kawamura, F. [Nuclear Systems Div., Hitachi, Ibaraki (Japan)

    2000-07-01

    Several countries had stopped developing fluoride volatility reprocessing method in the 1970's due to difficulties in recovering pure Pu. Although, nuclear societies recently favor dirty Pu (MOX). which has high proliferation resistance and needs remote fuel fabrication technologies. This situation reminded the authors to re-evaluate the fluoride volatility process. Preliminary investigation clarified that conventional fluoride volatility process could be simplified to recover dirty MOX and pure U from spent LWR fuels. Pure U is suitable to transfer it to re-enrichment (LWR cycle again), to storage certain period for future FBRs, and to dispose with relatively simple barrier. The improved process also enables to prepare directly the dirty MOX particles which are suitable for remote fuel fabrication (vibration packing). This paper describes the system of improved fluoride volatility reprocessing, and compatibility of each elemental process such as thermal decladding, two stage fluorination of U and U+Pu, U purification, direct conversion. of mixed fluoride into oxide particles and vibration packing fuel fabrication. (authors)

  15. A Review on Adsorption of Fluoride from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Mirna Habuda-Stanić

    2014-09-01

    Full Text Available Fluoride is one of the anionic contaminants which is found in excess in surface or groundwater because of geochemical reactions or anthropogenic activities such as the disposal of industrial wastewaters. Among various methods used for defluoridation of water such as coagulation, precipitation, membrane processes, electrolytic treatment, ion-exchange, the adsorption process is widely used. It offers satisfactory results and seems to be a more attractive method for the removal of fluoride in terms of cost, simplicity of design and operation. Various conventional and non-conventional adsorbents have been assessed for the removal of fluoride from water. In this review, a list of various adsorbents (oxides and hydroxides, biosorbents, geomaterials, carbonaceous materials and industrial products and by-products and its modifications from literature are surveyed and their adsorption capacities under various conditions are compared. The effect of other impurities on fluoride removal has also been discussed. This survey showed that various adsorbents, especially binary and trimetal oxides and hydroxides, have good potential for the fluoride removal from aquatic environments.

  16. Fluoride and aluminum release from restorative materials using ion chromatography

    Directory of Open Access Journals (Sweden)

    Zeynep Okte

    2012-02-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the amounts of fluoride and aluminum released from different restorative materials stored in artificial saliva and double-distilled water. Material and METHODS: Cylindrical specimens (10 x 1 mm were prepared from 4 different restorative materials (Kavitan Plus, Vitremer, Dyract Extra, and Surefil. For each material, 20 specimens were prepared, 10 of which were stored in 5 mL artificial saliva and 10 of which were stored in 5 mL of double-distilled water. Concentrations of fluoride and aluminum in the solutions were measured using ion chromatography. Measurements were taken daily for one week and then weekly for two additional weeks. Data were analyzed using two-way ANOVA and Duncan's multiple range tests (p<0.05. RESULTS: The highest amounts of both fluoride and aluminum were released by the resin-modified glass ionomer cement Vitremer in double-distilled water (p<0.05. All materials released significantly more fluoride in double-distilled water than in artificial saliva (p<0.05. In artificial saliva, none of the materials were observed to release aluminum. CONCLUSION: It was concluded that storage media and method of analysis should be taken into account when the fluoride and aluminum release from dental materials is assessed.

  17. Corrosion Behavior of Titanium Grade 7 in Fluoride-Containing NaCl Brines

    Energy Technology Data Exchange (ETDEWEB)

    Lian, T; Whalen, M T; Wong, L

    2004-10-25

    The effects of fluoride on the corrosion behavior of Titanium Grade 7 (0.12-0.25% Pd) have been investigated. Up to 0.1 mol/L fluoride was added to the NaCl brines at 95 C, and three pH values of 4, 8, and 11 were selected for studying pH dependence of fluoride effects. It was observed that fluoride significantly altered the anodic polarization behavior, at all three pH values of 4, 8, and 11. Under acidic condition fluoride caused active corrosion. The corrosion of Titanium grade 7 was increased by three orders of magnitude when a 0.1 mol/L fluoride was added to the NaCl brines at pH 4, and the Pd ennoblement effect was not observed in acidic fluoride-containing environments. The effects of fluoride were reduced significantly when pH was increased to 8 and above.

  18. A NOVEL BIO-WASTE INCORPORATED ALGINATE SORBENT FOR DE-FLUORIDATION OF WATER

    Directory of Open Access Journals (Sweden)

    Carmalin Sophia Ayyappan

    2015-09-01

    Full Text Available This study evaluates the feasibility of using tamarind (Tamarindus indica seed powder for de-fluoridation of fluoride contaminated water. Batch study confirmed that tamarind seeds in dry powder form could remove 87% of fluoride from water. This bio-sorbent can be used effectively in areas where fluoride concentrations are above the permissible limits of 1.5 mg·l-1 as per WHO Standard, 1984. Tamarind seed powder was incorporated in a matrix of sodium alginate and made into gel-beads. The beads were tested for de-fluoridation efficiency by conducting column studies. The effect of various factors, such as flow rate, retention time, and the number of runs on the efficacy of fluoride removal was also studied. The results revealed that flow rate did not seem to have much effect on the percentage fluoride removal but the fluoride concentration decreased drastically upon greater retention time and multiple runs.

  19. Caries status in 16 year-olds with varying exposure to water fluoridation in Ireland.

    LENUS (Irish Health Repository)

    Mullen, J

    2012-12-01

    Most of the Republic of Ireland\\'s public water supplies have been fluoridated since the mid-1960s while Northern Ireland has never been fluoridated, apart from some small short-lived schemes in east Ulster.

  20. Tetrabutylammonium fluoride promoted regiospecific reactions of trimethylsilyl-o-carborane with aldehydes

    International Nuclear Information System (INIS)

    Trimethylsilyl-o-carborane serves as o-carborane carbanion upon fluoride ion promoted reaction with carbonyl compounds. Thus, in the presence of tetrabutylammonium fluoride, trimethylsilyl-o-carborane undergoes facile, unprecedented, carbodesilylation with aromatic and aliphatic aldehydes. (author)

  1. Community-oriented administration of fluoride for the prevention of dental caries

    DEFF Research Database (Denmark)

    Petersen, P E; Baez, R J; Lennon, M A

    2012-01-01

    coverage. Participants acknowledged that automatic fluoridation through water, salt, and milk is the most effective and equitable strategy for the prevention of dental caries. Concerns were expressed that government-subsidized community fluoride prevention programs may face privatization. In addition...

  2. Analyse van fluoride en fosfaat in complexe milieumatrices met capillaire zone elektroforese

    NARCIS (Netherlands)

    Staden JJ van; Hoop MAGT van den; LAC

    1996-01-01

    Dit onderzoek bestudeert de toepasbaarheid van een eerder ontwikkelde methode voor de analyse van fluoride en fosfaat op meer complexe matrices zoals oppervlaktewater, loogextracten, grondwater en stemflowwater. De storende waterstofcarbonaat-piek bij de bepaling van fluoride in loogextracten ko

  3. Discovery of photospheric argon in very hot central stars of planetary nebulae and white dwarfs

    CERN Document Server

    Werner, K; Kruk, J W

    2007-01-01

    We report the first discovery of argon in hot evolved stars and white dwarfs. We have identified the ArVII 1063.55A line in some of the hottest known (Teff=95000-110000 K) central stars of planetary nebulae and (pre-) white dwarfs of various spectral type. We determine the argon abundance and compare it to theoretical predictions from stellar evolution theory as well as from diffusion calculations. We analyze high-resolution spectra taken with the Far Ultraviolet Spectroscopic Explorer. We use non-LTE line-blanketed model atmospheres and perform line-formation calculations to compute synthetic argon line profiles. We find a solar argon abundance in the H-rich central star NGC1360 and in the H-deficient PG1159 star PG1424+535. This confirms stellar evolution modeling that predicts that the argon abundance remains almost unaffected by nucleosynthesis. For the DAO-type central star NGC7293 and the hot DA white dwarfs PG0948+534 and REJ1738+669 we find argon abundances that are up to three orders of magnitude sma...

  4. Numerical study of breakdown pattern induced by an intense microwave under nitrogen and argon gases

    Science.gov (United States)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-07-01

    Filamentary plasma induced by microwave beam irradiation was reproduced in nitrogen and argon by combining fluid or particle plasma models with electromagnetic wave propagation. Transport coefficients used in the fluid model are estimated from particle simulation to maintain consistency of the breakdown structure between the fluid and particle models. A discrete structure was obtained using the one-dimensional (1D) fluid model, because a standing wave is generated in front of the plasma when the incident microwave beam is reflected by the overcritical plasma, which agrees with the breakdown structure obtained using the 1D particle model. A 2D plasma filament was also reproduced using the fluid model in nitrogen and argon. Reflection of the incident microwave in argon becomes stronger than that in nitrogen because of the denser argon plasma. Change in filament shape is induced in argon because the electric field is deformed at the plasma tip owing to stronger wave reflection from the neighboring filament. The propagation speed of the plasma front becomes larger in argon breakdown because of the larger ionization frequency and the larger diffusion coefficient.

  5. Condensed argon isentropic compression with ultrahigh magnetic field pressure: Experimental design. Post-shot report

    Energy Technology Data Exchange (ETDEWEB)

    Bykov, A.I.; Boriskov, G.V.; Dolotenko, M.I. [All-Russian Research Inst. of Experimental Physics, Sarov (Russian Federation)] [and others

    1996-12-31

    This report continues the series of work devoted to experimental study of a high-dense condensed argon state. Remember that according to work of Kwon et. al., hexagonal close-packed structure is profitable in terms of energy rather than face-centered argon structure (stable with zero pressure). What is most interesting and intriguing here is the issue of possible argon metallization, when it is compressed up to the densities more than 9.17 g/cm{sup 3}. In the experiment of 1995 (the arrangement and data are described in a cited reference) the authors recorded appearance of conductivity in argon, which is non-conductive in the initial state, when it is compressed more than a factor of four. The peak value of argon specific conductivity recorded in this experiment did not exceed 10 (Ohm x cm){sup {minus}1}. This value of conductivity is characteristic of semiconductors, but not metals, which have 10{sup 4} (Ohm x cm){sup {minus}1}. At this stage of the work the main attention is paid to recording of argon conductive state and studying the possibilities of multiframed radiography of the sample in the compressed state.

  6. Low radioactivity argon dark matter search results from the DarkSide-50 experiment

    CERN Document Server

    Agnes, P; Albuquerque, I F M; Alexander, T; Alton, A K; Arisaka, K; Back, H O; Baldin, B; Biery, K; Bonfini, G; Bossa, M; Bottino, B; Brigatti, A; Brodsky, J; Budano, F; Bussino, S; Cadeddu, M; Cadonati, L; Cadoni, M; Calaprice, F; Canci, N; Candela, A; Cao, H; Cariello, M; Carlini, M; Catalanotti, S; Cavalcante, P; Chepurnov, A; Cocco, A G; Covone, G; Crippa, L; D'Angelo, D; D'Incecco, M; Davini, S; De Cecco, S; De Deo, M; De Vincenzi, M; Derbin, A; Devoto, 25 A; Di Eusanio, F; Di Pietro, G; Edkins, E; Empl, A; Fan, A; Fiorillo, G; Fomenko, K; Forster, G; Franco, D; Gabriele, F; Galbiati, C; Giganti, C; Goretti, A M; Granato, F; Grandi, L; Gromov, M; Guan, M; Guardincerri, Y; Hackett, B R; Herner, K; Hungerford, E V; Ianni, Al; Ianni, An; James, I; Jollet, C; Keeter, K; Kendziora, C L; Kobychev, V; Koh, G; Korablev, D; Korga, G; Kubankin, A; Li, X; Lissia, M; Lombardi, P; Luitz, S; Ma, Y; Machulin, I N; Mandarano, A; Mari, S M; Maricic, J; Marini, L; Martoff, C J; Meregaglia, A; Meyers, P D; Miletic, T; Milincic, R; Montanari, D; Monte, A; Montuschi, M; Monzani, M; Mosteiro, P; Mount, B J; Muratova, V N; Musico, P; Napolitano, J; Nelson, A; Odrowski, S; Orsini, M; Ortica, F; Pagani, L; Pallavicini, M; Pantic, E; Parmeggiano, S; Pelczar, K; Pelliccia, N; Perasso, S; Pocar, A; Pordes, S; Pugachev, D A; Qian, H; Randle, K; Ranucci, G; Razeto, A; Reinhold, B; Renshaw, A L; Romani, A; Rossi, B; Rossi, N; Rountree, D; Sablone, D; Saggese, P; Saldanha, R; Sands, W; Sangiorgio, S; Savarese, C; Segreto, E; Semenov, D A; Shields, E; Singh, P N; Skorokhvatov, M D; Smallcomb, M; Smirnov, O; Sotnikov, A; Stanford, C; Suvorov, Y; Tartaglia, R; Tatarowicz, J; Testera, G; Tonazzo, A; Trinchese, P; Unzhakov, E V; Vishneva, A; Vogelaar, B; Wada, M; Walker, S; Wang, H; Wang, Y; Watson, A W; Westerdale, S; Wilhelmi, J; Wojcik, M M; Xiang, X; Xu, J; Yang, C; Yoo, J; Zavatarelli, S; Zec, A; Zhong, W; Zhu, C; Zuzel, G

    2015-01-01

    The DarkSide-50 dark matter search reports the first results obtained using a target of low-radioactivity argon extracted from underground sources. The experiment is located at the Laboratori Nazionali del Gran Sasso and uses a two-phase time projection chamber as a detector. A total of 155 kg of low radioactivity argon has been obtained, and we have determined that underground argon is depleted in Ar-39 by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. The underground argon was also found to contain (2.05 +- 0.13) mBq/kg of Kr-85. We found no evidence for dark matter in the form of WIMPs in 70.9 live-days of data with a fiducial mass of (36.9 +- 0.6) kg. When combined with our preceding search with an atmospheric argon target, we set a 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2 ) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2 ).

  7. Results from the first use of low radioactivity argon in a dark matter search

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P. [Universite Paris Diderot (France). et al.

    2016-04-08

    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 103 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10-44 cm2 (8.6 x 10-44 cm2, 8.0 x 10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2 , 10 TeV/c2).

  8. Effect of sodium fluoride in maternal and offspring rats and its amelioration

    Institute of Scientific and Technical Information of China (English)

    SnehaPanchal; RamtejJ. Verma

    2014-01-01

    High fluoride content is known to cause dental and skeletal abnormalities. In addition, present review indicates that sodium fluoride consumption caused increased number of r=esorptions and dead foetuses. Various skeletal anomalies such as wavy ribs, presence of 14th ribs, lacking 6th sternebrae and incompete ossification of skull occur. All these changes could be due to oxidative stress caused by fluoride consumption. Fluoride-induced changes could be successfully ameliorated by cotreatment with vitamins and calcium.

  9. Highly Selective Fluoride Recognition by a Simple Carbazole-based Hydrozone Derivative

    Institute of Scientific and Technical Information of China (English)

    TANG Li-jun; ZHAO Guo-you; HUANG Zhen-long; WANG Nan-nan; GUO Jiao-jiao

    2013-01-01

    A simple carbazole hydrozone derivative(1) was synthesized and used as an optical probe for fluoride recognition in CH3CN.Receptor 1 exhibited colorimetric and fluorescent dual-channel response to fluoride anions.Addition of fluoride to a receptor 1 solution in CH3CN induced a distinct color change from yellow to magenta,the solution also displayed significant fluorescence blue shift.Thus receptor 1 exhibited dual-channel responses to fluoride with a high selectivity and sensitivity.

  10. Bioactivity of Sodium Free Fluoride Containing Glasses and Glass-Ceramics

    OpenAIRE

    Xiaojing Chen; Xiaohui Chen; Brauer, Delia S.; Rory M. Wilson; Hill, Robert G.; Natalia Karpukhina

    2014-01-01

    The bioactivity of a series of fluoride-containing sodium-free calcium and strontium phosphosilicate glasses has been tested in vitro. Glasses with high fluoride content were partially crystallised to apatite and other fluoride-containing phases. The bioactivity study was carried out in Tris and SBF buffers, and apatite formation was monitored by XRD, FTIR and solid state NMR. Ion release in solutions has been measured using ICP-OES and fluoride-ion selective electrode. The results show that...

  11. Effects of fluoride in drinking water on health of deciduous teeth

    OpenAIRE

    Blagojević Duška; Stojšin Ivana

    2004-01-01

    INTRODUCTION High incidence of decayed deciduous teeth, as well as lack of adequate therapy, makes tooth decay prevention very important. One of the simplest ways to reduce tooth decay is fluoridation of drinking water. The optimal concentration of fluoride in drinking water is 1 ppm/l, and many waters naturally contain this quantity. Waters in Vojvodina are mainly poor in fluoride, except in a few regions. It has long been postulated that fluoride has a prophyilactic effect during intrauteri...

  12. Batch and Column Experiments on Fluoride Removal from Waters Using Modified Zeolite

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    High fluoride groundwater occurs widely in China, presenting a quite serious environmental problem. Zeolite from Xinyang, China was tested as the fluoride-removing adsorbent. Batch and column experiments on fluoride removal using modified zeolites treated with hydrochloric acid,sodium hydroxide, sodium chloride and ferric chloride, respectively show that 0. 1 mol/L HCImodified zeolite can be used as an adsorbent for fluoride, with an adsorption capacity of 173. 16mg/kg.

  13. Effect of high fluoride concentration in drinking water on children’s intelligence

    OpenAIRE

    Seraj B.; Shahrabi M; Falahzade M; Falahzade F; Akhondi N.

    2006-01-01

    Background and Aim: Human and animal studies linking fluoride with diminished intelligence have been published. Although adverse effects of high intake of fluoride on intelligence and mental acuity continue to be reported, they are still controversial. The aim of this research was to investigate the relationship between fluoride in drinking water and children's intelligence. Materials and Methods: In this cross sectional study, 41 children were selected from the high fluoride area with 2...

  14. Kinetic Analysis of 18F-Fluoride PET Images of Breast Cancer Bone Metastases

    OpenAIRE

    Doot, Robert K; Muzi, Mark; Peterson, Lanell M.; Schubert, Erin K; Gralow, Julie R.; Specht, Jennifer M.; Mankoff, David A.

    2010-01-01

    The most common site of metastasis for breast cancer is bone. Quantitative 18F-fluoride PET can estimate the kinetics of fluoride incorporation into bone as a measure of fluoride transport, bone formation, and turnover. The purpose of this analysis was to evaluate the accuracy and precision of 18F-fluoride model parameter estimates for characterizing regional kinetics in metastases and normal bone in breast cancer patients.

  15. Absorption, distribution and excretion of inhaled hydrogen fluoride in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Morris, J.B.

    1979-01-01

    Rats were subjected to whole body HF exposure for 6 hrs or to nose-only HF exposure for 1 hr. Total and/or ionic fluoride concentrations in selected tissues were determined at various times following exposure. In rats sacrificed 6 hrs after whole body exposure, dose-dependent increases in lung, plasma, and kidney total and ionic fluoride concentration occurred. Rats excreted more fluoride in the urine after whole body exposure than could be explained by the amount of HF inhaled. Considerable evidence suggests that airborne HF deposits on fur and is then ingested due to preening activity. Urinary fluoride excretion was increased by nose-only exposure. The urinary fluoride excretion accounted for approximately twice the fluoride estimated to be inhaled during exposure. Tissue fluoride concentrations were elevated immediately after nose-only exposure. Fluoride concentrations in lung and kidney returned to control levels within 12 hrs. Plasma fluoride concentration was slightly elevated 24 hrs after the start of the 1 hr exposure but was at control levels at 96 hrs. Immediately following nose-only exposure, lung ionic fluoride concentrations were less than plasma ionic fluoride concentrations suggesting that the fluoride in the lung had reached that site via plasma transport rather than by inhalation. A dose-dependent increase in plasma ionic fluoride concentration occurred after upper respiratory tract HF exposure providing strong evidence that fluoride is absorbed systemically from that site. The plasma ionic fluoride concentration after upper respiratory tract exposure was of sufficient magnitude to account for the plasma fluoride concentrations observed in intact nose-only exposed rats. (ERB)

  16. Effect of sodium fluoride in maternal and offspring rats and its amelioration

    Directory of Open Access Journals (Sweden)

    Sneha Panchal

    2014-03-01

    Full Text Available High fluoride content is known to cause dental and skeletal abnormalities. In addition, present review indicates that sodium fluoride consumption caused increased number of r=esorptions and dead foetuses. Various skeletal anomalies such as wavy ribs, presence of 14th ribs, lacking 6th sternebrae and incompete ossification of skull occur. All these changes could be due to oxidative stress caused by fluoride consumption. Fluoride-induced changes could be successfully ameliorated by cotreatment with vitamins and calcium.

  17. Fluorescent naphthalene-based benzene tripod for selective recognition of fluoride in physiological condition

    Indian Academy of Sciences (India)

    Barun kumar Datta; Chirantan Kar; Gopal Das

    2015-02-01

    Aluminium complex of a naphthalene-based benzene tripod ligand system has been reported for the selective recognition of fluoride in aqueous medium in physiological condition. The ligand can selectively recognize Al3+ through enhancement in the fluorescence intensity and this in situ formed aluminium complex recognizes fluoride through quenching of fluorescence. The receptor system detects fluoride in nanomolar range. The sensing property was extended for practical utility to sense fluoride in tap water, pond water and river water.

  18. Reducing Exposure to High Fluoride Drinking Water in Estonia—A Countrywide Study

    OpenAIRE

    Ene Indermitte; Astrid Saava; Enn Karro

    2014-01-01

    Fluoride is a naturally occurring contaminant in groundwater in Estonia. There are several regions in Estonia with fluoride contents in public water supplies as high as 7 mg/L. Long-term exposure to high-fluoride drinking water may have several adverse health effects, primarily dental fluorosis. The opportunities for exposure reduction rely highly on water treatment technologies. Since 2004 public water suppliers in Estonia have made efforts to diminish fluoride content in drinking water sys...

  19. The Effect of Acute Fluoride Poisoning on Nitric Oxide and Methemoglobin Formation in the Guinea pig

    OpenAIRE

    ŞİRELİ, Meltem

    2004-01-01

    To study the effect of acute fluoride poisoning on nitric oxide and methemoglobin formation, 250 mg/kg bw sodium fluoride was applied alone and verapamil was applied together with fluoride. Blood nitric oxide (Griess reaction) and calcium levels; hemoglobin, methemoglobin and hematocrit values; and erythrocyte counts were determined and compared with those of the controls. After the fluoride application it was found that there was a relative relationship between the increase in nitric oxide a...

  20. The Karlsruhe 4π barium fluoride detector

    International Nuclear Information System (INIS)

    A new experimental approach has been implemented for accurate measurements of neutron capture cross sections in the energy range from 5 to 200 keV. The Karlsruhe 4π Barium Fluoride Detector consists of 42 crystals shaped as hexagonal and pentagonal truncated pyramids forming a spherical shell with 10 cm inner radius and 15 cm thickness. All crystals are supplied with reflector and photomultiplier, thus representing independent gamma-ray detectors. Each detector module covers the same solid angle with respect to a gamma-ray source located in the centre. The energy resolution of the 4π detector is 14% at 662 keV and 7% at 2.5 MeV gamma-ray energy, the overall time reslution is 500 ps and the peak efficiency 90% at 1 MeV. The detector allows to register capture cascades with 95% probability above a threshold energy of 2.5 MeV in the sum energy spectrum. Neutrons are produced via the 7Li(p,n)7Be reaction using the pulsed proton beam of a Van de Graaff accelerator. The neutron spectrum can be taylored according to the experimental requirements in an energy range from 5 to 200 keV by choosing appropriate proton energies. A collimated neutron beam is passing through the detector and hits the sample in the centre. The energy of captured neutrons is determined via time of flight, the primary flight path being 77 cm. The combination of short primary flight path, a 10 cm inner radius of the spherical BaF2 shell, and the low capture cross section of barium allows to discriminate background due to capture of sample scattered neutrons in the scintillator by time of flight, leaving part of the neutron energy range completely undisturbed. (orig./HSI)