WorldWideScience

Sample records for area electric reliability

  1. Puget Sound Area Electric Reliability Plan : Draft Environmental Impact State.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1991-09-01

    The Puget Sound Area Electric Reliability Plan Draft Environmental Impact Statement (DEIS) identifies the alternatives for solving a power system problem in the Puget Sound area. This Plan is undertaken by Bonneville Power Administration (BPA), Puget Sound Power Light, Seattle City Light, Snohomish Public Utility District No. 1 (PUD), and Tacoma Public Utilities. The Plan consists of potential actions in Puget Sound and other areas in the State of Washington. A specific need exists in the Puget Sound area for balance between east-west transmission capacity and the increasing demand to import power generated east of the Cascades. At certain times of the year, there is more demand for power than the electric system can supply in the Puget Sound area. This high demand, called peak demand, occurs during the winter months when unusually cold weather increases electricity use for heating. The existing power system can supply enough power if no emergencies occur. However, during emergencies, the system will not operate properly. As demand grows, the system becomes more strained. To meet demand, the rate of growth of demand must be reduced or the ability to serve the demand must be increased, or both. The plan to balance Puget Sound's power demand and supply has these purposes: The plan should define a set of actions that would accommodate ten years of load growth (1994--2003). Federal and State environmental quality requirements should be met. The plan should be consistent with the plans of the Northwest Power Planning Council. The plan should serve as a consensus guideline for coordinated utility action. The plan should be flexible to accommodate uncertainties and differing utility needs. The plan should balance environmental impacts and economic costs. The plan should provide electric system reliability consistent with customer expectations. 29 figs., 24 tabs.

  2. Puget Sound area electric reliability plan. Draft environmental impact statement

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    The Puget Sound Area Electric Reliability Plan Draft Environmental Impact Statement (DEIS) identifies the alternatives for solving a power system problem in the Puget Sound area. This Plan is undertaken by Bonneville Power Administration (BPA), Puget Sound Power & Light, Seattle City Light, Snohomish Public Utility District No. 1 (PUD), and Tacoma Public Utilities. The Plan consists of potential actions in Puget Sound and other areas in the State of Washington. A specific need exists in the Puget Sound area for balance between east-west transmission capacity and the increasing demand to import power generated east of the Cascades. At certain times of the year, there is more demand for power than the electric system can supply in the Puget Sound area. This high demand, called peak demand, occurs during the winter months when unusually cold weather increases electricity use for heating. The existing power system can supply enough power if no emergencies occur. However, during emergencies, the system will not operate properly. As demand grows, the system becomes more strained. To meet demand, the rate of growth of demand must be reduced or the ability to serve the demand must be increased, or both. The plan to balance Puget Sound`s power demand and supply has these purposes: The plan should define a set of actions that would accommodate ten years of load growth (1994--2003). Federal and State environmental quality requirements should be met. The plan should be consistent with the plans of the Northwest Power Planning Council. The plan should serve as a consensus guideline for coordinated utility action. The plan should be flexible to accommodate uncertainties and differing utility needs. The plan should balance environmental impacts and economic costs. The plan should provide electric system reliability consistent with customer expectations. 29 figs., 24 tabs.

  3. Puget Sound Area Electric Reliability Plan : Final Environmental Impact Statement.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-04-01

    A specific need exists in the Puget Sound area for balance between east-west transmission capacity and the increasing demand to import power generated east of the Cascades. At certain times of the year, and during certain conditions, there is more demand for power in the Puget Sound area than the transmission system and existing generation can reliably supply. This high demand, called peak demand occurs during the winter months when unusually cold weather increases electricity use for heating. The existing power system can supply enough power if no emergencies occur. However, during emergencies the system will not operate properly. As demand grows, the system becomes more strained. To meet demand, the rate of growth of demand must be reduced or the ability to serve the demand must be increased, or both.

  4. Bringing Reliable Electricity to Rural Areas of the Philippines

    OpenAIRE

    Cariaga, Art; Jed A. Sevilla; Fernando-Pacua, Marianna; Beloe, William Trant

    2009-01-01

    Electric Cooperatives (ECs) in the Philippines are generally undercapitalized, and their operational performance is poor. As a result, the supply of electricity in rural areas is unstable, with frequent outages and fluctuating voltages. International Finance Corporation (IFC) Philippines advisory services found that a principal reason was the ECs' lack of sound capital expenditure (capex) ...

  5. Hawaii electric system reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Silva Monroy, Cesar Augusto; Loose, Verne William

    2012-09-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers' views of reliability %E2%80%9Cworth%E2%80%9D and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers' views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.

  6. Puget Sound Area Electric Reliability Plan. Appendix B : Local Generation Evaluation : Draft Environmental Impact Statement.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1991-09-01

    The information and data contained in this Appendix was extracted from numerous sources. The principle sources used for technical data were Bonneville Power Administration's 1990 Resource Program along with its technical appendix, and Chapter 8 of the Draft 1991 Northwest Conservation and Electric Power Plan. All cost data is reported 1988 dollars unless otherwise noted. This information was supplemented by other data developed by Puget Sound utilities who participated on the Local Generation Team. Identifying generating resources available to the Puget Sound area involved a five step process: (1) listing all possible resources that might contribute power to the Puget Sound area, (2) characterizing the technology/resource status, cost and operating characteristics of these resources, (3) identifying exclusion criteria based on the needs of the overall Puget Sound Electric Reliability Plan study, (4) applying these criteria to the list of resources, and (5) summarizing of the costs and characteristics of the final list of resources. 15 refs., 20 tabs.

  7. Area of Interest 1. Interregional Electricity Reliability Issue and Assessment Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-07-01

    In 2010, the U.S. Department of Energy (DOE) tasked Lawrence Berkeley National Laboratory (LBNL) and the Pacific Northwest National Laboratory (PNNL), in separate contracts, to provide coordinated technical support to the electricity industry for two national electricity reliability initiatives. The first initiative focused on improving the frequency response of each of the three North American interconnections. The second initiative focused on improving industry understanding of the causes and consequences of fault-induced delayed voltage recovery, which has been observed in all three interconnections. Both initiatives were conducted in close coordination with the North American Electric Reliability Corporation (NERC) and the Western Electric Coordination Council (WECC) and involved the participation of leading utilities from across the United States. This is the final report on LBNL’s activities. It consists of summaries of each activity, including references to published documents that were prepared through the course of the project. (Activities under taken by PNNL are reported on in a separate report.)

  8. Puget Sound Area Electric Reliability Plan : Appendix E, Transmission Reinforcement Analysis.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-04-01

    The purpose of this appendix to the draft environmental impact statement (EIS) report is to provide an update of the latest study work done on transmission system options for the Puget Sound Area Electric Reliability Plan. Also included in the attachments to the EIS are 2 reports analyzing the voltage stability of the Puget Sound transmission system and a review by Power Technologies, Inc. of the BPA voltage stability analysis and reactive options. Five transmission line options and several reactive options are presently being considered as possible solutions to the PSAFRP by the Transmission Team. The first two line options would be built on new rights-of way adjacent (as much as possible) to existing corridors. The reactive options would optimize the existing transmission system capability by adding new stations for series capacitors and/or switchgear. The other three line options are rebuilds or upgrades of existing cross mountain transmission lines. These options are listed below and include a preliminary assessment of the additional transmission system reinforcement required to integrate the new facilities into the existing transmission system. Plans were designed to provide at least 500 MVAR reactive margin.

  9. Puget Sound Area Electric Reliability Plan : Scoping Summary Report - Part B Preliminary Technical Analysis Appendix A.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1991-09-01

    This report describes in general terms the nature of the voltage instability problem facing the Puget Sound area. The following two chapters cover the technical aspects of the problem. It deals with load growth, the root cause of the problem. Also addressed is the capacity of the current power system and the criteria for future system planning. It also explains the technical results of transmission system modeling which confirm the system's vulnerability to voltage instability, the principal symptom of the problem. The results of the scoping process in each of the four measure categories are presented. Included are lists of all options identified, a discussion of the screening criteria, and descriptions of the measures that survived the screening process and are proposed for further evaluation in Phase 2. We discuss the evaluation methodology which will be used to refine the analyses. The next steps in the planning process are outlined. It also describes the short term operational agreements that will assure continued reliable service until a long term solution is in place. 8 figs., 22 tabs.

  10. Reliability impact of solar electric generation upon electric utility systems

    Science.gov (United States)

    Day, J. T.; Hobbs, W. J.

    1982-08-01

    The introduction of solar electric systems into an electric utility grid brings new considerations in the assessment of the utility's power supply reliability. This paper summarizes a methodology for estimating the reliability impact of solar electric technologies upon electric utilities for value assessment and planning purposes. Utility expansion and operating impacts are considered. Sample results from photovoltaic analysis show that solar electric plants can increase the reliable load-carrying capability of a utility system. However, the load-carrying capability of the incremental power tends to decrease, particularly at significant capacity penetration levels. Other factors influencing reliability impact are identified.

  11. Reliability quantification and visualization for electric microgrids

    Science.gov (United States)

    Panwar, Mayank

    and parallel with the area Electric Power Systems (EPS), (3) includes the local EPS and may include portions of the area EPS, and (4) is intentionally planned. A more reliable electric power grid requires microgrids to operate in tandem with the EPS. The reliability can be quantified through various metrics for performance measure. This is done through North American Electric Reliability Corporation (NERC) metrics in North America. The microgrid differs significantly from the traditional EPS, especially at asset level due to heterogeneity in assets. Thus, the performance cannot be quantified by the same metrics as used for EPS. Some of the NERC metrics are calculated and interpreted in this work to quantify performance for a single asset and group of assets in a microgrid. Two more metrics are introduced for system level performance quantification. The next step is a better representation of the large amount of data generated by the microgrid. Visualization is one such form of representation which is explored in detail and a graphical user interface (GUI) is developed as a deliverable tool to the operator for informative decision making and planning. Electronic appendices-I and II contain data and MATLAB© program codes for analysis and visualization for this work.

  12. 18 CFR 39.3 - Electric Reliability Organization certification.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electric Reliability... CERTIFICATION OF THE ELECTRIC RELIABILITY ORGANIZATION; AND PROCEDURES FOR THE ESTABLISHMENT, APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.3 Electric Reliability Organization certification. (a)...

  13. 76 FR 23222 - Electric Reliability Organization Interpretation of Transmission Operations Reliability

    Science.gov (United States)

    2011-04-26

    ... Energy Regulatory Commission 18 CFR Part 40 Electric Reliability Organization Interpretation of Transmission Operations Reliability AGENCY: Federal Energy Regulatory Commission. ACTION: Notice of Proposed... Commission (Commission) proposes to approve the North American Electric Reliability Corporation's...

  14. Novel approach for evaluation of service reliability for electricity customers

    Institute of Scientific and Technical Information of China (English)

    KANG ChongQing; GAO Yan; JIANG John N; ZHONG Jin; XIA Qing

    2009-01-01

    Understanding reliability value for electricity customer is important to market-based reliability man-agement. This paper proposes a novel approach to evaluate the reliability for electricity customers by using indifference curve between economic compensation for power interruption and service reliability of electricity. Indifference curve is formed by calculating different planning schemes of network ex-pansion for different reliability requirements of customers, which reveals the information about eco-nomic values for different reliability levels for electricity customers, so that the reliability based on market supply demand mechanism can be established and economic signals can be provided for reli-ability management and enhancement.

  15. Novel approach for evaluation of service reliability for electricity customers

    Institute of Scientific and Technical Information of China (English)

    JIANG; John; N

    2009-01-01

    Understanding reliability value for electricity customer is important to market-based reliability management. This paper proposes a novel approach to evaluate the reliability for electricity customers by using indifference curve between economic compensation for power interruption and service reliability of electricity. Indifference curve is formed by calculating different planning schemes of network expansion for different reliability requirements of customers, which reveals the information about economic values for different reliability levels for electricity customers, so that the reliability based on market supply demand mechanism can be established and economic signals can be provided for reliability management and enhancement.

  16. 76 FR 23801 - North American Electric Reliability Corporation; Order Approving Reliability Standard

    Science.gov (United States)

    2011-04-28

    ... violation risk factor assignment.\\14\\ \\14\\ See North American Electric Reliability Corp., 119 FERC ] 61,145... Energy Regulatory Commission North American Electric Reliability Corporation; Order Approving Reliability..., John R. Norris, and Cheryl A. LaFleur. 1. On February 11, 2011, the North American Electric...

  17. 76 FR 23171 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Science.gov (United States)

    2011-04-26

    ... the system remains functional, the information can be compelled by the Reliability Coordinator. \\32... reliability coordinator and neighboring systems upon request, or when the loss of the communication channel... (Technical Information), Office of Electric Reliability, Federal Energy Regulatory Commission, 888...

  18. 78 FR 29209 - Revisions to Electric Reliability Organization Definition of Bulk Electric System and Rules of...

    Science.gov (United States)

    2013-05-17

    ... to Electric Reliability Organization Definition of Bulk Electric System and Rules of Procedure; Final...; ] DEPARTMENT OF ENERGY Federal Energy Regulatory Commission 18 CFR Part 40 Revisions to Electric Reliability Organization Definition of Bulk Electric System and Rules of Procedure AGENCY: Federal Energy...

  19. Reliability Evaluation for Optimizing Electricity Supply in a Developing Country

    Directory of Open Access Journals (Sweden)

    Mark Ndubuka NWOHU

    2007-09-01

    Full Text Available The reliability standards for electricity supply in a developing country, like Nigeria, have to be determined on past engineering principles and practice. Because of the high demand of electrical power due to rapid development, industrialization and rural electrification; the economic, social and political climate in which the electric power supply industry now operates should be critically viewed to ensure that the production of electrical power should be augmented and remain uninterrupted. This paper presents an economic framework that can be used to optimize electric power system reliability. Finally the cost models are investigated to take into account the economic analysis of system reliability, which can be periodically updated to improve overall reliability of electric power system.

  20. Potential for deserts to supply reliable renewable electric power

    Science.gov (United States)

    Labordena, Mercè; Lilliestam, Johan

    2015-04-01

    To avoid dangerous climate change, the electricity systems must be decarbonized by mid-century. The world has sufficient renewable electricity resources for complete power sector decarbonization, but an expansion of renewables poses several challenges for the electricity systems. First, wind and solar PV power are intermittent and supply-controlled, making it difficult to securely integrate this fluctuating generation into the power systems. Consequently, power sources that are both renewable and dispatchable, such as biomass, hydro and concentrating solar power (CSP), are particularly important. Second, renewable power has a low power density and needs vast areas of land, which is problematic both due to cost reasons and due to land-use conflicts, in particular with agriculture. Renewable and dispatchable technologies that can be built in sparsely inhabited regions or on land with low competition with agriculture would therefore be especially valuable; this land-use competition greatly limits the potential for hydro and biomass electricity. Deserts, however, are precisely such low-competition land, and are at the same time the most suited places for CSP generation, but this option would necessitate long transmission lines from remote places in the deserts to the demand centers such as big cities. We therefore study the potential for fleets of CSP plants in the large deserts of the world to produce reliable and reasonable-cost renewable electricity for regions with high and/or rapidly increasing electricity demand and with a desert within or close to its borders. The regions in focus here are the European Union, North Africa and the Middle East, China and Australia. We conduct the analysis in three steps. First, we identify the best solar generation areas in the selected deserts using geographic information systems (GIS), and applying restrictions to minimize impact on biodiversity, soils, human heath, and land-use and land-cover change. Second, we identify

  1. Seismic reliability assessment of electric power systems

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, A. [Stanford Univ., CA (United States); Bouabid, J. [Risk Management Solutions, Menlo Park, CA (United States)

    1995-12-31

    This paper presents a methodology for the seismic risk assessment of electric power systems. In evaluating damage and loss of functionality to the electric power components, fragility curves and restoration functions are used. These vulnerability parameters are extracted from the GIS-based regional loss estimation methodology being developed for the US. Observed damage in electric power components during the Northridge earthquake is used to benchmark the methodology. The damage predicted using these vulnerability parameters is found to be in good agreement with the damage observed during the earthquake.

  2. CERTS: Consortium for Electric Reliability Technology Solutions - Research Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph

    2003-07-30

    Historically, the U.S. electric power industry was vertically integrated, and utilities were responsible for system planning, operations, and reliability management. As the nation moves to a competitive market structure, these functions have been disaggregated, and no single entity is responsible for reliability management. As a result, new tools, technologies, systems, and management processes are needed to manage the reliability of the electricity grid. However, a number of simultaneous trends prevent electricity market participants from pursuing development of these reliability tools: utilities are preoccupied with restructuring their businesses, research funding has declined, and the formation of Independent System Operators (ISOs) and Regional Transmission Organizations (RTOs) to operate the grid means that control of transmission assets is separate from ownership of these assets; at the same time, business uncertainty, and changing regulatory policies have created a climate in which needed investment for transmission infrastructure and tools for reliability management has dried up. To address the resulting emerging gaps in reliability R&D, CERTS has undertaken much-needed public interest research on reliability technologies for the electricity grid. CERTS' vision is to: (1) Transform the electricity grid into an intelligent network that can sense and respond automatically to changing flows of power and emerging problems; (2) Enhance reliability management through market mechanisms, including transparency of real-time information on the status of the grid; (3) Empower customers to manage their energy use and reliability needs in response to real-time market price signals; and (4) Seamlessly integrate distributed technologies--including those for generation, storage, controls, and communications--to support the reliability needs of both the grid and individual customers.

  3. Seismic reliability analysis of large electric power systems

    Institute of Scientific and Technical Information of China (English)

    何军; 李杰

    2004-01-01

    Based on the De. Morgan laws and Boolean simplification, a recursive decomposition method is introduced in this paper to identity the main exclusive safe paths and failed paths of a network. The reliability or the reliability bound of a network can be conveniently expressed as the summation of the joint probabilities of these paths. Under the multivariate normal distribution assumption, a conditioned reliability index method is developed to evaluate joint probabilities of various exclusive safe paths and failed paths, and, finally, the seismic reliability or the reliability bound of an electric power system.Examples given in thc paper show that the method is very simple and provides accurate results in the seismic reliability analysis.

  4. Reliability and maintainability analysis of electrical system of drum shearers

    Institute of Scientific and Technical Information of China (English)

    SEYED Hadi Hoseinie; MOHAMMAD Ataei; REZA Khalokakaie; UDAY Kumar

    2011-01-01

    The reliability and maintainability of electrical system of drum shearer at Parvade.l Coal Mine in central Iran was analyzed. The maintenance and failure data were collected during 19 months of shearer operation. According to trend and serial correlation tests, the data were independent and identically distributed (iid) and therefore the statistical techniques were used for modeling. The data analysis show that the time between failures (TBF) and time to repair (TTR) data obey the lognormal and Weibull 3 parameters distribution respectively. Reliability-based preventive maintenance time intervals for electrical system of the drum shearer were calculated with regard to reliability plot. The reliability-based maintenance intervals for 90%, 80%, 70% and 50% reliability level are respectively 9.91, 17.96, 27.56 and 56.1 h. Also the calculations show that time to repair (TTR) of this system varies in range 0.17-4 h with 1.002 h as mean time to repair (MTTR). There is a 80% chance that the electrical system of shearer of Parvade.l mine repair will be accomplished within 1.45 h.

  5. Load As A Reliability Resource in the Restructured Electricity Market

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, J.D.

    2002-06-10

    Recent electricity price spikes are painful reminders of the value that meaningful demand-side responses could bring to the restructuring US electricity system. Review of the aggregate offers made by suppliers confirms that even a modest increase in demand elasticity could dramatically reduce these extremes in price volatility. There is a strong need for dramatically increased customer participation in these markets to enhance system reliability and reduce price volatility. Indeed, allowing customers to manage their loads in response to system conditions might be thought of as the ultimate reliability resource. Most would agree that meaningful demand-side responses to price are the hallmark of a well-functioning competitive market [1]. Yet, in today's markets for electricity, little or no such response is evident. The reason is simple: customers currently do not experience directly the time-varying costs of their consumption decisions. Consequently, they have no incentive to modify these decisions in ways that might enhance system reliability or improve the efficiency of the markets in which electricity is traded. Increased customer participation is a necessary step in the evolution toward more efficient markets for electricity and ancillary services. This scoping report provides a three-part assessment of the current status of efforts to enhance the ability of customer's load to participate in competitive markets with a specific focus on the role of customer loads in enhancing electricity system reliability. First, this report considers the definitions of electricity-reliability-enhancing ancillary services (Section 2) and a preliminary assessment of the ability of customer's loads to provide these services. Second, is a review a variety of programs in which load has been called on as a system reliability resource (Section 3). These experiences, drawn from both past and current utility and ISO programs, focus on programs triggered by system

  6. 76 FR 66057 - North American Electric Reliability Corporation; Order Approving Regional Reliability Standard

    Science.gov (United States)

    2011-10-25

    ... new definitions. The regional Reliability Standard requires transmission owners and generator owners... requirements for its area's dynamic disturbance recording needs; and establishes disturbance data reporting... which applicable entities are subject to mandatory compliance, with full compliance required within...

  7. Electrical Reliability of a Film-Type Connection during Bending

    Directory of Open Access Journals (Sweden)

    Ryosuke Mitsui

    2015-10-01

    Full Text Available With the escalating demands for downsizing and functionalizing mobile electronics, flexible electronics have become an important aspect of future technologies. To address limitations concerning junction deformation, we developed a new connection method using a film-type connector that is less than 0.1 mm thick. The film-type connector is composed of an organic film substrate, a UV-curable adhesive that deforms elastically under pressure, and electrodes that are arranged on the adhesive. The film-type connection relies on a plate-to-plate contact, which ensures a sufficient contact area. The electrical reliability of the film-type connection was investigated based on changes in the resistance during bending at curvature radii of 70, 50, 25, 10, 5, and 2.5 mm. The connection was bent 1000 times to investigate the reproducibility of the connector’s bending properties. The tests showed that no disconnections occurred due to bending in the vertical direction of the electrode, but disconnections were observed due to bending in the parallel direction at curvature radii of 10, 5, and 2.5 mm. In addition, the maximum average change in resistance was less than 70 milliohms unless a disconnection was generated. These results support the application of the new film-type connection in future flexible devices.

  8. VT Electric Utility Franchise Areas

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) ELCFRANCHISE includes Vermont's Electric Utility Franchise boundaries. It is a compilation of many data sources. The boundaries are approximate...

  9. 75 FR 14097 - Revision to Electric Reliability Organization Definition of Bulk Electric System

    Science.gov (United States)

    2010-03-24

    ... Environmental Policy Act, Order No. 486, 52 FR 47897 (Dec. 17, 1987), FERC Stats. & Regs., Regs. Preambles 1986...; ] DEPARTMENT OF ENERGY Federal Energy Regulatory Commission 18 CFR Part 40 61,204] Revision to Electric Reliability Organization Definition of Bulk Electric System March 18, 2010. AGENCY: Federal Energy...

  10. Reliability-based generation resource planning in electricity markets

    OpenAIRE

    Moghaddam, Maziar Mirhosseini; Javidi, Mohammad Hossein

    2014-01-01

    This paper proposes a reliability-based competitive generation resource planning model in electricity markets. The Monte Carlo simulation method is applied to consider random outages of generation units and transmission lines as well as load uncertainty. In order to determine the optimal plan for installation of candidate generating units, the decisions of generation companies (GenCos) and the independent system operators (ISOs) are investigated. The method is based on an iterative pro...

  11. American lifelines alliance efforts to improve electric power transmission reliability

    Science.gov (United States)

    Nishenko, S.P.; Savage, W.U.; Honegger, D.G.; McLane, T.R.; ,

    2002-01-01

    A study was performed on American Lifelines Alliance (ALA) efforts to improve electric power transmission reliability. ALA is a public-private partnership project, with the goal of reducing risks to lifelines from natural hazards and human threat events. The mechanism used by ALA for developing national guidelines for lifeline systems is dependent upon using existing Standards Developing Organizations (SDO) accredited by the American National Standards Institute (ANSI) as means to achieve national consensus.

  12. Basic Principles of Electrical Network Reliability Optimization in Liberalised Electricity Market

    Science.gov (United States)

    Oleinikova, I.; Krishans, Z.; Mutule, A.

    2008-01-01

    The authors propose to select long-term solutions to the reliability problems of electrical networks in the stage of development planning. The guide lines or basic principles of such optimization are: 1) its dynamical nature; 2) development sustainability; 3) integrated solution of the problems of network development and electricity supply reliability; 4) consideration of information uncertainty; 5) concurrent consideration of the network and generation development problems; 6) application of specialized information technologies; 7) definition of requirements for independent electricity producers. In the article, the major aspects of liberalized electricity market, its functions and tasks are reviewed, with emphasis placed on the optimization of electrical network development as a significant component of sustainable management of power systems.

  13. Analyzing Distributed Generation Impact on the Reliability of Electric Distribution Network

    Directory of Open Access Journals (Sweden)

    Sanaullah Ahmad

    2016-10-01

    Full Text Available With proliferation of Distribution Generation (DG and renewable energy technologies the power system is becoming more complex, with passage of time the development of distributed generation technologies is becoming diverse and broad. Power system reliability is one of most vital area in electric power system which deals with continuous supply of power and customer satisfaction. Distribution network in power system contributed up to 80% of reliability problems. This paper analyzes the impact of Wind Turbine Generator (WTG as a distribution generation source on reliability of distribution system. Injecting single WTG and close to load point has positive impact on reliability, while injecting multiple WTGs at single place has adverse impact on distribution system reliability. These analyses are performed on bus 2 of Roy Billinton Test System (RBTS.

  14. Behavioral ecology, endocrinology and signal reliability of electric communication

    Science.gov (United States)

    Gavassa, Sat; Goldina, Anna; Silva, Ana C.; Stoddard, Philip K.

    2013-01-01

    Summary The balance between the costs and benefits of conspicuous animal communication signals ensures that signal expression relates to the quality of the bearer. Signal plasticity enables males to enhance conspicuous signals to impress mates and competitors and to reduce signal expression to lower energetic and predation-related signaling costs when competition is low. While signal plasticity may benefit the signaler, it can compromise the reliability of the information conveyed by the signals. In this paper we review the effect of signal plasticity on the reliability of the electrocommunication signal of the gymnotiform fish Brachyhypopomus gauderio. We (1) summarize the endocrine regulation of signal plasticity, (2) explore the regulation of signal plasticity in females, (3) examine the information conveyed by the signal, (4) show how that information changes when the signal changes, and (5) consider the energetic strategies used to sustain expensive signaling. The electric organ discharge (EOD) of B. gauderio changes in response to social environment on two time scales. Two hormone classes, melanocortins and androgens, underlie the short-term and long-term modulation of signal amplitude and duration observed during social interaction. Population density drives signal amplitude enhancement, unexpectedly improving the reliability with which the signal predicts the signaler's size. The signal's second phase elongation predicts androgen levels and male reproductive condition. Males sustain signal enhancement with dietary intake, but when food is limited, they ‘go for broke’ and put extra energy into electric signals. Cortisol diminishes EOD parameters, but energy-limited males offset cortisol effects by boosting androgen levels. While physiological constraints are sufficient to maintain signal amplitude reliability, phenotypic integration and signaling costs maintain reliability of signal duration, consistent with theory of honest signaling. PMID:23761465

  15. Parameter estimation and reliable fault detection of electric motors

    Institute of Scientific and Technical Information of China (English)

    Dusan PROGOVAC; Le Yi WANG; George YIN

    2014-01-01

    Accurate model identification and fault detection are necessary for reliable motor control. Motor-characterizing parameters experience substantial changes due to aging, motor operating conditions, and faults. Consequently, motor parameters must be estimated accurately and reliably during operation. Based on enhanced model structures of electric motors that accommodate both normal and faulty modes, this paper introduces bias-corrected least-squares (LS) estimation algorithms that incorporate functions for correcting estimation bias, forgetting factors for capturing sudden faults, and recursive structures for efficient real-time implementation. Permanent magnet motors are used as a benchmark type for concrete algorithm development and evaluation. Algorithms are presented, their properties are established, and their accuracy and robustness are evaluated by simulation case studies under both normal operations and inter-turn winding faults. Implementation issues from different motor control schemes are also discussed.

  16. Amended Electric Field Distribution: A Reliable Technique for Electrical Performance Improvement in Nano scale SOI MOSFETs

    Science.gov (United States)

    Ramezani, Zeinab; Orouji, Ali A.

    2017-04-01

    To achieve reliable transistors, we propose a new silicon-on-insulator (SOI) metal-oxide-semiconductor field-effect transistor (MOSFET) with an amended electric field in the channel for improved electrical and thermal performance, with an emphasis on current leakage improvement. The amended electric field leads to lower electric field crowding and thereby we assume enhanced reliability, leakage current, gate-induced drain leakage (GIDL), and electron temperature. To modify the electric field distribution, an additional rectangular metal region (RMR) is utilized in the buried oxide of the SOI MOSFET. The location and dimensions of the RMR have been carefully optimized to achieve the best results. The electrical, thermal, and radiofrequency characteristics of the proposed structure were analyzed using two-dimensional (2-D) numerical simulations and compared with the characteristics of the conventional, fully depleted SOI MOSFET (C-SOI). Also, critical short-channel effects (SCEs) such as threshold voltage, drain-induced barrier lowering (DIBL), subthreshold slope degradation, hot-carrier effect, GIDL, and leakage power consumption are improved. According to the results obtained, the proposed nano SOI MOSFET is a reliable device, especially for use in low-power and high-temperature applications.

  17. Thermal Management and Reliability of Power Electronics and Electric Machines

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, Sreekant

    2016-06-13

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.

  18. Thermal Management and Reliability of Power Electronics and Electric Machines

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, Sreekant

    2016-08-03

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil -- by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines will be presented.

  19. Thermal Management and Reliability of Power Electronics and Electric Machines

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, Sreekant

    2016-09-19

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.

  20. Electric Service Areas, Area showing what electric company serves a particular area, Published in 2004, Johnson County AIMS.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Service Areas dataset, was produced all or in part from Other information as of 2004. It is described as 'Area showing what electric company serves a...

  1. 75 FR 41166 - Office of Electricity Delivery and Energy Reliability; Notice of Reestablishment of the...

    Science.gov (United States)

    2010-07-15

    ... of Electricity Delivery and Energy Reliability; Notice of Reestablishment of the Electricity Advisory... the Electricity Advisory Committee has been reestablished for a two-year period. The Committee will provide advice to the Office of Electricity Delivery and Energy Reliability (DOE), on its programs...

  2. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    Energy Technology Data Exchange (ETDEWEB)

    Touati, Said; Chennai, Salim; Souli, Aissa [Nuclear Research Centre of Birine, Ain Oussera, Djelfa Province (Algeria)

    2015-07-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  3. An Examination of Temporal Trends in Electricity Reliability Based on Reports from U.S. Electric Utilities

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; LaCommare, Kristina Hamachi; Larsen, Peter; Todd, Annika; Fisher, Emily

    2012-01-06

    Since the 1960s, the U.S. electric power system has experienced a major blackout about once every 10 years. Each has been a vivid reminder of the importance society places on the continuous availability of electricity and has led to calls for changes to enhance reliability. At the root of these calls are judgments about what reliability is worth and how much should be paid to ensure it. In principle, comprehensive information on the actual reliability of the electric power system and on how proposed changes would affect reliability ought to help inform these judgments. Yet, comprehensive, national-scale information on the reliability of the U.S. electric power system is lacking. This report helps to address this information gap by assessing trends in U.S. electricity reliability based on information reported by electric utilities on power interruptions experienced by their customers. Our research augments prior investigations, which focused only on power interruptions originating in the bulk power system, by considering interruptions originating both from the bulk power system and from within local distribution systems. Our research also accounts for differences among utility reliability reporting practices by employing statistical techniques that remove the influence of these differences on the trends that we identify. The research analyzes up to 10 years of electricity reliability information collected from 155 U.S. electric utilities, which together account for roughly 50% of total U.S. electricity sales. The questions analyzed include: 1. Are there trends in reported electricity reliability over time? 2. How are trends in reported electricity reliability affected by the installation or upgrade of an automated outage management system? 3. How are trends in reported electricity reliability affected by the use of IEEE Standard 1366-2003?

  4. Reliability of electrical power systems for coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Razgil' deev, G.I.; Kovalev, A.P.; Serkyuk, L.I.

    1982-01-01

    This is a method for evaluating the reliability of comprehensive mining power systems. The systems reliability is influenced by the selectivity of maximum protection, ground-short protection, the subdivision of the circuitry, the character of the systems failures, etc.

  5. Improving the AODV Protocol to Satisfy the Required Level of Reliability for Home Area Networks

    Directory of Open Access Journals (Sweden)

    Hossein Jafari Pozveh

    2016-06-01

    Full Text Available For decades, the structure of existing power grids has not changed. It is an old structure that depends heavily on fossil fuel as an energy source, and in the future, this is likely to be critical in the field of energy. To solve these problems and to make optimal use of energy resources, a new concept is proposed, called Smart Grid. Smart Grid is an electric power distribution automation system, which can provide a two-way flow of electricity and information between power plants and consumers. The Smart Grid communications infrastructure consists of different network components, such as Home Area Network (HAN, Neighborhood Area Network (NAN and Wide Area Network (WAN. Achieving the required level of reliability in the transmission of information to all sections, including the HAN, is one of the main objectives in the design and implementation of Smart Grid. This study offers a routing protocol by considering the parameters and constraints of HAN, which, by improving AODV routing protocol, achieves the level of required reliability for data transmission in this network. These improvements include: making table-driven AODV routing protocol, extending the routing protocol to compute multiple paths in a route discovery, simplification and providing the effect of HAN parameters. The results of the NS2 simulation indicate that applying this improved routing protocol in the HAN, satisfies the required level of reliability of the network, which is over 98%.

  6. Reliability Analyses of Transmission and Substation Facilities and Electricity Supply to Urban Consumers in 2007

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ Renabilities of transmission and substation facilities with voltaelevel of 220kV or above In 2007,there were totally 356 power supply enterprises,including 28 EHV transmission and substation enterprises,and 245 power generation enterprises submitting reliability performances of electric facilities at a voltage level of 220 kV or above to the Electric Power Reliability Management Center.The reliability indices of transmission and substation facilities in 2007 and 2006 are shown in Table 1.

  7. Reliability Assessment of Offshore Wind Turbines Considering Faults of Electrical / Mechanical Components

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2013-01-01

    of structural, mechanical and electrical components are important, in order to optimally plan Operation & Maintenance strategies. A general model for reliability estimation of structural, mechanical or electrical components is described. For a representative failure mode a corresponding limit state...... is considered and related to reliability estimation by taking into account faults e.g. due to failure of an electrical component or loss of grid....

  8. Reliability and safety of the electrical power supply complex of the Hanford production reactors

    Energy Technology Data Exchange (ETDEWEB)

    Robbins, F.D.

    1960-09-15

    Safety has been and must continue to be the inviolable modulus by which the operation of a nuclear reactor must be judged. A malfunction in any reactor may well result in a release of fission products which may dissipate over a wide geographical area. Such dissipation may place the health, happiness and even the lives of the people in the region in serious jeopardy. As a result, the property damage and liability cost may reach astronomical values in the order of magnitude of billions of dollars. Reliability of the electrical network is an indispensable factor in attaining a high order of safety assurance. Progress in the peaceful use of atomic energy may take the form of electrical power generation using the nuclear reactor as a source of thermal energy. In view of these factors it seems appropriate and profitable that a critical engineering study be made of the safety and reliability of the Hanford reactors without regard to cost economics. This individual and independent technical engineering analysis was made without regard to Hanford traditional engineering and administration assignments. The main objective has been to focus attention on areas which seem to merit further detailed study on conditions which seem to need adjustment but most of all on those changes which will improve reactor safety. This report is the result of such a study.

  9. 76 FR 66055 - North American Electric Reliability Corporation; Order Approving Interpretation of Reliability...

    Science.gov (United States)

    2011-10-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal... Interpretation of Reliability Standard; Before Commissioners: Jon Wellinghoff, Chairman; Philip D. Moeller, John... Procedure, Appendix 3A, Reliability Standards Development Procedure, Version 6.1, at 27-29 (2010). II....

  10. Assessment and Improving Methods of Reliability Indices in Bakhtar Regional Electricity Company

    Directory of Open Access Journals (Sweden)

    Saeed Shahrezaei

    2013-04-01

    Full Text Available Reliability of a system is the ability of a system to do prospected duties in future and the probability of desirable operation for doing predetermined duties. Power system elements failures data are the main data of reliability assessment in the network. Determining antiseptic parameters is the goal of reliability assessment by using system history data. These parameters help to recognize week points of the system. In other words, the goal of reliability assessment is operation improving and decreasing of the failures and power outages. This paper is developed to assess reliability indices of Bakhtar Regional Electricity Company up to 1393 and the improving methods and their effects on the reliability indices in this network. DIgSILENT Power Factory software is employed for simulation. Simulation results show the positive effect of improving methods in reliability indices of Bakhtar Regional Electricity Company.

  11. Electrical distribution studies for the 200 Area tank farms

    Energy Technology Data Exchange (ETDEWEB)

    Fisler, J.B.

    1994-08-26

    This is an engineering study providing reliability numbers for various design configurations as well as computer analyses (Captor/Dapper) of the existing distribution system to the 480V side of the unit substations. The objective of the study was to assure the adequacy of the existing electrical system components from the connection at the high voltage supply point through the transformation and distribution equipment to the point where it is reduced to its useful voltage level. It also was to evaluate the reasonableness of proposed solutions of identified deficiencies and recommendations of possible alternate solutions. The electrical utilities are normally considered the most vital of the utility systems on a site because all other utility systems depend on electrical power. The system accepts electric power from the external sources, reduces it to a lower voltage, and distributes it to end-use points throughout the site. By classic definition, all utility systems extend to a point 5 feet from the facility perimeter. An exception is made to this definition for the electric utilities at this site. The electrical Utility System ends at the low voltage section of the unit substation, which reduces the voltage from 13.8 kV to 2,400, 480, 277/480 or 120/208 volts. These transformers are located at various distances from existing facilities. The adequacy of the distribution system which transports the power from the main substation to the individual area substations and other load centers is evaluated and factored into the impact of the future load forecast.

  12. 76 FR 60820 - North American Electric Reliability Corporation; Notice of Technical Conference

    Science.gov (United States)

    2011-09-30

    ... physically unprotected. The Commission is interested in: (1) Information on the number of Bulk- Power System... Energy Regulatory Commission North American Electric Reliability Corporation; Notice of Technical... Technical Conference to discuss issues related to the interpretations of Reliability Standard CIP-006-2...

  13. Trends in Control Area of PLC Reliability and Safety Parameters

    Directory of Open Access Journals (Sweden)

    Juraj Zdansky

    2008-01-01

    Full Text Available Extension of the PLC application possibilities is closely related to increase of reliability and safety parameters. If the requirement of reliability and safety parameters will be suitable, the PLC could by implemented to specific applications such the safety-related processes control. The goal of this article is to show the way which producers are approaching to increase PLC`s reliability and safety parameters. The second goal is to analyze these parameters for range of present choice and describe the possibility how the reliability and safety parameters can be affected.

  14. 78 FR 43198 - Flexible and Local Resources Needed for Reliability in the California Wholesale Electric Market...

    Science.gov (United States)

    2013-07-19

    ... Wholesale Electric Market; Notice of Staff Technical Conference This notice establishes the agenda and... facilitate a structured dialogue on the reliability and risk-of-retirement concerns raised in the FLRR... Electric Market July 31, 2013 The technical conference is intended to facilitate a structured dialogue...

  15. Electric Power Infrastructure Reliability and Security (EPIRS) Reseach and Development Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Rick Meeker; L. Baldwin; Steinar Dale; Alexander Domijan; Davild Larbalestier; Hui Li; Peter McLaren; Sastry Pamidi; Horatio Rodrigo; Michael Steurer

    2010-03-31

    Power systems have become increasingly complex and face unprecedented challenges posed by population growth, climate change, national security issues, foreign energy dependence and an aging power infrastructure. Increased demand combined with increased economic and environmental constraints is forcing state, regional and national power grids to expand supply without the large safety and stability margins in generation and transmission capacity that have been the rule in the past. Deregulation, distributed generation, natural and man-made catastrophes and other causes serve to further challenge and complicate management of the electric power grid. To meet the challenges of the 21st century while also maintaining system reliability, the electric power grid must effectively integrate new and advanced technologies both in the actual equipment for energy conversion, transfer and use, and in the command, control, and communication systems by which effective and efficient operation of the system is orchestrated - in essence, the 'smart grid'. This evolution calls for advances in development, integration, analysis, and deployment approaches that ultimately seek to take into account, every step of the way, the dynamic behavior of the system, capturing critical effects due to interdependencies and interaction. This approach is necessary to better mitigate the risk of blackouts and other disruptions and to improve the flexibility and capacity of the grid. Building on prior Navy and Department of Energy investments in infrastructure and resources for electric power systems research, testing, modeling, and simulation at the Florida State University (FSU) Center for Advanced Power Systems (CAPS), this project has continued an initiative aimed at assuring reliable and secure grid operation through a more complete understanding and characterization of some of the key technologies that will be important in a modern electric system, while also fulfilling an education and

  16. MONITORING OF LARGE INSTABLE AREAS: system reliability and new tools.

    Science.gov (United States)

    Leandro, G.; Mucciarelli, M.; Pellicani, R.; Spilotro, G.

    2009-04-01

    The monitoring of unstable or potentially unstable areas is a necessary operation every time you can not remove the conditions of risk and apply to mitigation measures. In Italian Apennine regions there are many urban or extra-urban areas affected by instability, for which it is impracticable to remove hazard conditions, because of size and cost problems. The technological evolution exportable to the field of land instability monitoring is particularly lively and allows the use of warning systems unthinkable just few years ago. However, the monitoring of unstable or potentially unstable areas requires a very great knowledge of the specific problems, without which the reliability of the system may be dangerously overestimated. The movement may arise, indeed, in areas not covered by instrumentation, or covered with vegetation that prevents the acquisition of both reflected signals in the multi-beam laser techniques and radar signals. Environmental conditions (wind, concentrated sources of light, temperature changes, presence of animals) may also invalidate the accuracy of the measures, by introducing modulations or disturbance at a level well above the threshold of alarm signal, leading consequently to raise the values of the warning threshold. The Authors have gained long experience with the observation and monitoring of some large landslides in the Southern Apennine (Aliano, Buoninventre, Calciano, Carlantino, etc.) and unstable areas also at regional scale. One of the most important experiences is about the case of landslides of extensive areas, where unstable and stables zones coexist along transverse and longitudinal axis. In many of these cases you need the accurate control of the movement at selected points to evaluate the trend of displacement velocity, which can be achieved by means of a single-beam laser. The control of these movements, however, does not provide information on stress pattern into the stable areas. Among the sensitive precursors, acoustic

  17. Assessing Changes in the Reliability of the U.S. Electric Power System

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Peter H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stanford Univ., CA (United States). Dept. of Physics; LaCommare, Kristina H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, James L. [Stanford Univ., CA (United States)

    2015-08-01

    Over the past 15 years, the most well-publicized efforts to assess trends in U.S. electric power system reliability have focused only on a subset of all power interruption events (see, for example, Amin 2008 and Campbell 2012)—namely, only the very largest events, which trigger immediate emergency reporting to federal agencies and industry regulators. Anecdotally, these events are thought by many to represent no more than 10% of the power interruptions experienced annually by electricity consumers. Moreover, a review of these emergency reports has identified shortcomings in relying on these data as reliable sources for assessing trends, even with the reliability events they report (Fisher et al. 2012). Recent work has begun to address these limitations by examining trends in reliability data collected annually by electricity distribution companies (Eto et al. 2012). In principle, all power interruptions experienced by electricity customers, regardless of size, are recorded by the distribution utility. Moreover, distribution utilities have a long history of recording this information, often in response to mandates from state public utility commissions (Eto et al. 2006). Thus, studies that rely on reliability data collected by distribution utilities can, in principle, provide a more complete basis upon which to assess trends or changes in reliability over time.

  18. 75 FR 80391 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Science.gov (United States)

    2010-12-22

    ... power system stabilizers in the types of information that transmission operators are expected to share... inter-Transmission Operator impact (e.g., could potentially affect transmission flows resulting in a SOL... operation of that Special Protection System on inter-area flows. The Transmission Operator shall...

  19. A Generalized Model for Electrical Power Distribution Feeders’ Contributions to System Reliability Indices

    Directory of Open Access Journals (Sweden)

    Ganiyu A. Ajenikoko

    2014-01-01

    Full Text Available Reliability indices are parametric quantities used to assess the performance levels of electrical power distribution systems. In this work, a generalized quadratic model is developed for electrical power distribution system contributions to system reliability indices using Ikeja, Port-Harcourt, Kaduna and Kano distribution system feeders as case studies. The mean System Average Interruption Duration Index (SAIDI, System Average Interruption Frequency Index (SAIFI and Customer Average Interruption Duration Index (CAIDI contributions to system reliability indices for Ikeja, Port-Harcourt, Kaduna and Kano distribution systems were 0.0033, 0.0026, 0.0033 and 0.0018 respectively due to the fact that a prolonged period of interruptions was recorded on most of the feeders attached to Port-Harcourt and Kano distribution systems making them to be less reliable compared to Ikeja and Kaduna distribution systems. The generalized Quadratic model forms a basis for a good design, planning and maintenance of distribution systems at large.

  20. High Electricity Demand in the Northeast U.S.: PJM Reliability Network and Peaking Unit Impacts on Air Quality.

    Science.gov (United States)

    Farkas, Caroline M; Moeller, Michael D; Felder, Frank A; Henderson, Barron H; Carlton, Annmarie G

    2016-08-01

    On high electricity demand days, when air quality is often poor, regional transmission organizations (RTOs), such as PJM Interconnection, ensure reliability of the grid by employing peak-use electric generating units (EGUs). These "peaking units" are exempt from some federal and state air quality rules. We identify RTO assignment and peaking unit classification for EGUs in the Eastern U.S. and estimate air quality for four emission scenarios with the Community Multiscale Air Quality (CMAQ) model during the July 2006 heat wave. Further, we population-weight ambient values as a surrogate for potential population exposure. Emissions from electricity reliability networks negatively impact air quality in their own region and in neighboring geographic areas. Monitored and controlled PJM peaking units are generally located in economically depressed areas and can contribute up to 87% of hourly maximum PM2.5 mass locally. Potential population exposure to peaking unit PM2.5 mass is highest in the model domain's most populated cities. Average daily temperature and national gross domestic product steer peaking unit heat input. Air quality planning that capitalizes on a priori knowledge of local electricity demand and economics may provide a more holistic approach to protect human health within the context of growing energy needs in a changing world.

  1. Reliability Analysis of Piezoelectric Truss Structures Under Joint Action of Electric and Mechanical Loading

    Institute of Scientific and Technical Information of China (English)

    YANG Duo-he; AN Wei-guang; ZHU Rong-rong; MIAO Han

    2006-01-01

    Based on the finite element method(FEM) for the dynamical analysis of piezoelectric truss structures, the expressions of safety margins of strength fracture and damage electric field in the structure element are given considering electromechanical coupling effect under the joint action of electric and mechanical load. By importing the stochastic FEM,reliability of piezoelectric truss structures is analyzed by solving for partial derivative in the process of solving dynamical response of structure system with mode-superposition method. The influence of electromechanical coupling effect to reliability index is then analyzed through an example.

  2. Flexibility and reliability in long-term planning exercises dedicated to the electricity sector

    Energy Technology Data Exchange (ETDEWEB)

    Maizi, Nadia; Drouineau, Mathilde; Assoumou, Edi; Mazauric, Vincent

    2010-09-15

    Long-term planning models are useful to build plausible options for future energy systems and must consequently address the technological feasibility and associated cost of these options. This paper focuses on the electricity sector and on problems of flexibility and reliability in power systems in order to improve results provided by long-term planning exercises: flexibility needs are integrated as an additional criterion for new investment decisions and, reliability requirements are assessed through the level of electrical losses they induced and a related cost. These approaches are implemented in a long-term planning model and demonstrated through a study of the Reunion Island.

  3. Electric service reliability cost/worth assessment in a developing country

    Science.gov (United States)

    Pandey, Mohan Kumar

    Considerable work has been done in developed countries to optimize the reliability of electric power systems on the basis of reliability cost versus reliability worth. This has yet to be considered in most developing countries, where development plans are still based on traditional deterministic measures. The difficulty with these criteria is that they cannot be used to evaluate the economic impacts of changing reliability levels on the utility and the customers, and therefore cannot lead to an optimum expansion plan for the system. The critical issue today faced by most developing countries is that the demand for electric power is high and growth in supply is constrained by technical, environmental, and most importantly by financial impediments. Many power projects are being canceled or postponed due to a lack of resources. The investment burden associated with the electric power sector has already led some developing countries into serious debt problems. This thesis focuses on power sector issues facing by developing countries and illustrates how a basic reliability cost/worth approach can be used in a developing country to determine appropriate planning criteria and justify future power projects by application to the Nepal Integrated Electric Power System (NPS). A reliability cost/worth based system evaluation framework is proposed in this thesis. Customer surveys conducted throughout Nepal using in-person interviews with approximately 2000 sample customers are presented. The survey results indicate that the interruption cost is dependent on both customer and interruption characteristics, and it varies from one location or region to another. Assessments at both the generation and composite system levels have been performed using the customer cost data and the developed NPS reliability database. The results clearly indicate the implications of service reliability to the electricity consumers of Nepal, and show that the reliability cost/worth evaluation is both

  4. The development of the Czech Republic electric industry - Reliable, safe and responsible source mix

    Energy Technology Data Exchange (ETDEWEB)

    Vrba, Miroslav; Jez, Jiri; Ptacek, Jiri

    2010-09-15

    The paper focuses on the development of the Czech Republic electric industry in close perspective and the prediction of its expected future in period up to 2030. The goal of the paper is to specify methods and procedures applied within periodic assessment of Czech electric power sector balance outlook for the State authorities. A necessity to respect economic recession and politicization of the issue of power sector development has invoked that these items are added to commonly used procedures. A key criterion is the reliable and safe electricity supply by adequate source mix for acceptable prices and environmental aspects.

  5. Estimated Value of Service Reliability for Electric Utility Customers in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, M.J.; Mercurio, Matthew; Schellenberg, Josh

    2009-06-01

    Information on the value of reliable electricity service can be used to assess the economic efficiency of investments in generation, transmission and distribution systems, to strategically target investments to customer segments that receive the most benefit from system improvements, and to numerically quantify the risk associated with different operating, planning and investment strategies. This paper summarizes research designed to provide estimates of the value of service reliability for electricity customers in the US. These estimates were obtained by analyzing the results from 28 customer value of service reliability studies conducted by 10 major US electric utilities over the 16 year period from 1989 to 2005. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods it was possible to integrate their results into a single meta-database describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the US for industrial, commercial, and residential customers. Estimated interruption costs for different types of customers and of different duration are provided. Finally, additional research and development designed to expand the usefulness of this powerful database and analysis are suggested.

  6. Evaluation of conventional electric power generating industry quality assurance and reliability practices

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.T.; Lauffenburger, H.A.

    1981-03-01

    The techniques and practices utilized in an allied industry (electric power generation) that might serve as a baseline for formulating Quality Assurance and Reliability (QA and R) procedures for photovoltaic solar energy systems were studied. The study results provide direct near-term input for establishing validation methods as part of the SERI performance criteria and test standards development task.

  7. 75 FR 26748 - Notice of Commissioner and Staff Attendance at North American Electric Reliability Corporation...

    Science.gov (United States)

    2010-05-12

    ... Commissioner and Staff Attendance at North American Electric Reliability Corporation Meetings May 5, 2010. The... staff may attend the following meetings: May 11 (1 p.m.-5 p.m.) and 12 (8 a.m.-1 p.m.), 2010. North.... Hyatt Regency Baltimore on the Inner Harbor, 300 Light Street, Baltimore, MD 21202. Further...

  8. R&D program benefits estimation: DOE Office of Electricity Delivery and Energy Reliability

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2006-12-04

    The overall mission of the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE) is to lead national efforts to modernize the electric grid, enhance the security and reliability of the energy infrastructure, and facilitate recovery from disruptions to the energy supply. In support of this mission, OE conducts a portfolio of research and development (R&D) activities to advance technologies to enhance electric power delivery. Multiple benefits are anticipated to result from the deployment of these technologies, including higher quality and more reliable power, energy savings, and lower cost electricity. In addition, OE engages State and local government decision-makers and the private sector to address issues related to the reliability and security of the grid, including responding to national emergencies that affect energy delivery. The OE R&D activities are comprised of four R&D lines: High Temperature Superconductivity (HTS), Visualization and Controls (V&C), Energy Storage and Power Electronics (ES&PE), and Distributed Systems Integration (DSI).

  9. 77 FR 32629 - North American Electric Reliability Corporation; Notice of Filing

    Science.gov (United States)

    2012-06-01

    ... with any FERC Online service, please email FERCOnlineSupport@ferc.gov , or call (866) 208-3676 (toll... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission North American Electric Reliability Corporation; Notice of Filing...

  10. 77 FR 45598 - North American Electric Reliability Corporation; Notice of Filing

    Science.gov (United States)

    2012-08-01

    ... FERC Online service, please email FERCOnlineSupport@ferc.gov , or call (866) 208-3676 (toll free). For... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission North American Electric Reliability Corporation; Notice of Filing...

  11. 75 FR 57761 - North American Electric Reliability Corporation; Notice of Filing September 14, 2010.

    Science.gov (United States)

    2010-09-22

    ... document is added to a subscribed docket(s). For assistance with any FERC Online service, please e-mail... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission North American Electric Reliability Corporation; Notice of Filing...

  12. ASCERTAINMENT OF ELECTRIC-SUPPLY SCHEMES RELIABILITY FOR THE ATOMIC POWER PLANT AUXILIARIES

    Directory of Open Access Journals (Sweden)

    A. L. Starzhinskij

    2015-01-01

    Full Text Available The paper completes ascertainment of electrical-supply scheme reliability for the auxiliaries of a nuclear power plant. Thereat the author considers the system behavior during the block normal operation, carrying out current maintenance, and capital repairs in combination with initiating events. The initiating events for reactors include complete blackout, i.e. the loss of outside power supply (normal and reserve; emergency switching one of the working turbogenerators; momentary dumping the normal rating to the level of auxiliaries with seating the cutout valve of one turbo-generator. The combination of any initiating event with the repairing mode in case of one of the system elements failure should not lead to blackout occurrence of more than one system of the reliable power supply. This requirement rests content with the help of the reliable power supply system self-dependence (electrical and functional and the emergency power-supply operational autonomy (diesel generator and accumulator batteries.The reliability indicators of the power supply system for the nuclear power plant auxiliaries are the conditional probabilities of conjoined blackout of one, two, and three sections of the reliable power supply conditional upon an initiating event emerging and the blackout of one, two, and three reliable power-supply sections under the normal operational mode. Furthermore, they also are the blackout periodicity of one and conjointly two, three, and four sections of normal operation under the block normal operational mode. It is established that the blackout of one bus section of normal operation and one section of reliable power-supply system of the auxiliaries that does not lead to complete blackout of the plant auxiliaries may occur once in three years. The probability of simultaneous power failure of two or three normal-operation sections and of two reliable power-supply sections during the power plant service life is unlikely.

  13. Reliability measurement for mixed mode failures of 33/11 kilovolt electric power distribution stations.

    Directory of Open Access Journals (Sweden)

    Faris M Alwan

    Full Text Available The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter [Formula: see text] and shape parameters [Formula: see text] and [Formula: see text]. Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models.

  14. 78 FR 803 - Revisions to Electric Reliability Organization Definition of Bulk Electric System and Rules of...

    Science.gov (United States)

    2013-01-04

    ...-benefit analysis accompanying the revised definition represents an additional gap in the process for... potential for gaps in coverage of facilities.'' \\10\\ \\9\\ Id. P 75; see also Order No. 693-A, 120 FERC ] 61... exempt facilities from inclusion in the bulk electric system within one year of the effective date of...

  15. Scoping study on trends in the economic value of electricity reliability to the U.S. economy

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph; Koomey, Jonathan; Lehman, Bryan; Martin, Nathan; Mills, Evan; Webber, Carrie; Worrell, Ernst

    2001-06-01

    During the past three years, working with more than 150 organizations representing public and private stakeholders, EPRI has developed the Electricity Technology Roadmap. The Roadmap identifies several major strategic challenges that must be successfully addressed to ensure a sustainable future in which electricity continues to play an important role in economic growth. Articulation of these anticipated trends and challenges requires a detailed understanding of the role and importance of reliable electricity in different sectors of the economy. This report is intended to contribute to that understanding by analyzing key aspects of trends in the economic value of electricity reliability in the U.S. economy. We first present a review of recent literature on electricity reliability costs. Next, we describe three distinct end-use approaches for tracking trends in reliability needs: (1) an analysis of the electricity-use requirements of office equipment in different commercial sectors; (2) an examination of the use of aggregate statistical indicators of industrial electricity use and economic activity to identify high reliability-requirement customer market segments; and (3) a case study of cleanrooms, which is a cross-cutting market segment known to have high reliability requirements. Finally, we present insurance industry perspectives on electricity reliability as an example of a financial tool for addressing customers' reliability needs.

  16. Electric toothbrush application is a reliable and valid test for differentiating temporomandibular disorders pain patients from controls

    Directory of Open Access Journals (Sweden)

    Schiffman Eric L

    2009-07-01

    Full Text Available Abstract Background Current methods for identifying patients with pain hypersensitivity are sufficiently complex to limit their widespread application in clinical settings. We assessed the reliability and validity of a simple multi-modal vibrotactile stimulus, applied using an electric toothbrush, to evaluate its potential as a screening tool for central sensitization. Methods Fourteen female temporomandibular disorders (TMD subjects with myofascial pain (RDC/TMD Ia or Ib and arthralgia (RDC/TMD IIIa were compared to 13 pain-free controls of matched age and gender. Vibrotactile stimulus was performed with an electric toothbrush, applied with 1 pound pressure for 30 seconds in four locations: over the lateral pole of the temporomandibular joint, masseter, temporalis, and mid-ventral surface of forearm. Pain intensity (0–10 was recorded following the stimulus at 0, 15, 30, and 60 seconds. Test-retest reliability was assessed with measurements from 8 participants, taken 2–12 hours apart. Case versus control differentiation involved comparison of area under the curve (AUC. A receiver operating characteristic (ROC curve was used to determine cutoff AUC scores for maximum sensitivity and specificity for this multi-modal vibrotactile stimulus. Results Test-retest reliability resulted in an ICC of 0.87 for all 4 pooled sites. ROC-determined AUC cutoff scores resulted in a sensitivity of 57% and specificity of 92% for all 4 pooled sites. Conclusion The electric toothbrush stimulus had excellent test-retest reliability. Validity of the scores was demonstrated with modest sensitivity and good specificity for differentiating TMD pain patients from controls, which are acceptable properties for a screening test.

  17. The research of controller area network on hybrid electrical vehicle

    Institute of Scientific and Technical Information of China (English)

    Wu Hongxing; Song Liwei; Kou Baoquan; Cheng Shukang

    2006-01-01

    It is of increasing importance to design and implement vehicle networks for transferring information between electrical control units on Hybrid Electrical Vehicle (HEV). This paper presents a scheme of using Controller Area Network (CAN) technology to realize communication and datasharing between the electrical units on the HEV. The principle and communication protocol of Electrical Control Units (ECU) CAN node are introduced. By considering different sensitivity of the devices to the latency of data transportation, a new design procedure is proposed for the purpose of simplifying network codes and wiring harness, reducing assembly space and weight, improving assembly efficiency, and enhancing fault-diagnose in auto networks.

  18. Space Station Freedom power - A reliability, availability, and maintainability assessment of the proposed Space Station Freedom electric power system

    Science.gov (United States)

    Turnquist, S. R.; Twombly, M.; Hoffman, D.

    1989-01-01

    A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.

  19. 75 FR 72909 - Revision to Electric Reliability Organization Definition of Bulk Electric System

    Science.gov (United States)

    2010-11-26

    ... substation at a single transmission voltage by one or more transmission circuits; (2) tap lines and... concentration of load served by these lines. It asserts that transmission facilities such as these that move... interconnections. The 138 kV system in the Astoria area includes six major substations that are interconnected...

  20. Reliability and Validity of Ultrasound Cross Sectional Area Measurements for Long-Duration Spaceflight

    Science.gov (United States)

    Scott, Jessica M.; Martin, David S.; Cunningham, David; Matz, Timothy; Caine, Timothy; Hackney, Kyle J.; Arzeno, Natalia; Ploutz-Snyder, Lori

    2010-01-01

    Limb muscle atrophy and the accompanying decline in function can adversely affect the performance of astronauts during mission-related activities and upon re-ambulation in a gravitational environment. Previous characterization of space flight-induced muscle atrophy has been performed using pre and post flight magnetic resonance imaging (MRI). In addition to being costly and time consuming, MRI is an impractical methodology for assessing in-flight changes in muscle size. Given the mobility of ultrasound (US) equipment, it may be more feasible to evaluate changes in muscle size using this technique. PURPOSE: To examine the reliability and validity of using a customized template to acquire panoramic ultrasound (US) images for determining quadriceps and gastrocnemius anatomical cross sectional area (CSA). METHODS: Vastus lateralis (VL), rectus femoris (RF), medial gastrocnemius (MG), and lateral gastrocnemius (LG) CSA were assessed in 10 healthy individuals (36+/-2 yrs) using US and MRI. Panoramic US images were acquired by 2 sonographers using a customized template placed on the thigh and calf and analyzed by the same 2 sonographers (CX50 Philips). MRI images of the leg were acquired while subjects were supine in a 1.5T scanner (Signa Horizon LX, General Electric) and were analyzed by 3 trained investigators. The average of the 2 US and 3 MRI values were used for validity analysis. RESULTS: High inter-experimenter reliability was found for both the US template and MRI analysis as coefficients of variation across muscles ranged from 2.4 to 4.1% and 2.8 to 3.8%, respectively. Significant correlations were found between US and MRI CSA measures (VL, r = 0.85; RF, r = 0.60; MG, r = 0.86; LG, r = 0.73; p < 0.05). Furthermore, the standard error of measurement between US and MRI ranged from 0.91 to 2.09 sq cm with high limits of agreement analyzed by Bland-Altman plots. However, there were significant differences between absolute values of MRI and US for all muscles

  1. STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY

    Institute of Scientific and Technical Information of China (English)

    Qiu Baoyun; Huang Jiyan; Yuan Shouqi

    2004-01-01

    Characters of head of low head pump station and the pump shaft power are analyzed. Influence of each single factor on pump shaft power is expressed as change of specific shaft power (non-dimensional) and the probability density function is determined. Influences of multiple factors on pump shaft power are analyzed. Method of calculating none over-loaded probability of motor by integration by successive reductions is put forward and then relation between power spare coefficient and none over-loaded reliability of electric motor is established. Influences of all factors on pump shaft power being considered completely; power spare coefficients of motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-out conditions. Electrical motor power spare coefficients should be chosen as 1.20~1.44, 1.11~1.19, 1.09~1.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much to reasonable choose of electrical motors in large pump stations, increasing reliability of pump units and saving equipment investment.

  2. Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay

    Institute of Scientific and Technical Information of China (English)

    YAO Fang; ZHENG Jian-rong; HUANG Zhang-wu

    2007-01-01

    The dynamic contact resistances of HH52P electromagnetic relays are measured under different ambient air temperature. Their diagnostic parameters are extracted and determined. It is found that the ambient air temperature obviously influences some parameters. In order to research its influence on the electrical contact reliability of electromagnetic relay, the statistic analysis is applied to study the static contact resistance, the max of the dynamic contact resistance and the bounce time. It is found that the ambient air temperature regularly influences the three parameters. Thoroughly, the phenomenon is studied and analyzed in the point of material science so as to probe into the essential matter of it.

  3. Method for evaluating the reliability of compressor impeller of turbocharger for vehicle application in plateau area

    Science.gov (United States)

    Wang, Zheng; Wang, Zengquan; Wang, A.-na; Zhuang, Li; Wang, Jinwei

    2016-10-01

    As turbocharging diesel engines for vehicle application are applied in plateau area, the environmental adaptability of engines has drawn more attention. For the environmental adaptability problem of turbocharging diesel engines for vehicle application, the present studies almost focus on the optimization of performance match between turbocharger and engine, and the reliability problem of turbocharger is almost ignored. The reliability problem of compressor impeller of turbocharger for vehicle application when diesel engines operate in plateau area is studied. Firstly, the rule that the rotational speed of turbocharger changes with the altitude height is presented, and the potential failure modes of compressor impeller are analyzed. Then, the failure behavior models of compressor impeller are built, and the reliability models of compressor impeller operating in plateau area are developed. Finally, the rule that the reliability of compressor impeller changes with the altitude height is studied, the measurements for improving the reliability of the compressor impellers of turbocharger operating in plateau area are given. The results indicate that when the operating speed of diesel engine is certain, the rotational speed of turbocharger increases with the increase of altitude height, and the failure risk of compressor impeller with the failure modes of hub fatigue and blade resonance increases. The reliability of compressor impeller decreases with the increase of altitude height, and it also decreases as the increase of number of the mission profile cycle of engine. The method proposed can not only be used to evaluating the reliability of compressor impeller when diesel engines operate in plateau area but also be applied to direct the structural optimization of compressor impeller.

  4. Modular terminations for electrical and optical cables with increased reliability and simplified installation

    Energy Technology Data Exchange (ETDEWEB)

    Painter, Howard E.; Barlow, Stewart M.; Ramasubramanian, Srikanth [Ocean Design, Inc., Ormond Beach, FL (United States)

    2008-07-01

    A second generation enabling cable termination technology called FACT G2 (Field Assembled Cable Termination Generation 2) has been developed to extend the operational depth and significantly increase the reliability of cable terminations. This modularized system completely isolates the cable elements from the pressure-balanced region and the ambient environment. This approach to cable termination eliminates cable-dependent design limitations and common mode/single point failures that have previously been identified in subsea applications. This technology is suitable for both electrical and optical cables, as well as hybrid (electro-optical) cables. This paper will focus on both electrical and optical cable FACTs and will provide an overview of previous field experiences that led to the development of a modular FACT termination system, the design basis specification (10,000 psi) and the rigorous qualification testing program of the components, sub-assemblies and the FACT termination system. In addition, uses of this technology to date will be summarized, including projects in Brazil such as the Chevron Frade (electrical) and Shell BC-10 (electrical and optical). (author)

  5. Reliable Communication in Wireless Body Area Sensor Network for Health Monitoring

    CERN Document Server

    Bahanfar, Saeid; Kousha, Helia; Babaie, Shahram

    2011-01-01

    Now days, interests in the application of Wireless Body Area Network (WBAN) have grown considerably. A number of tiny wireless sensors, strategically placed on the human body, create a wireless body area network that can monitor various vital signs, providing real-time feedback to the user and medical personnel. This communication needs to be energy efficient and highly reliable while keeping delays low. In this paper we present hardware and software architecture for BAN and also we offer reliable communication and data aggregation.

  6. Electrical utility generating system reliability analysis code, SYSREL. Social cost studies program

    Energy Technology Data Exchange (ETDEWEB)

    Hub, K.; Conley, L.; Buehring, W.; Rowland, B.; Stephenson, M.

    1975-09-01

    The system reliability code, SYSREL, is a system planning tool that can be used to assess the reliability and economic performance of alternative expansion patterns of electric utility generation systems. Given input information such as capacity, forced-outage rate, number of weeks of annual scheduled maintenance, and economic data for individual units along with the expected load characteristics, the code produces estimates of the mean time between system failures, required reserve capacity to meet a specified system-failure-frequency criterion, expected energy generation from each unit, and system energy cost. The categories of calculations performed by the code are maintenance scheduling, reliability, capacity requirement, energy production allocation, and energy cost. The code is designed to examine alternative generating units and system expansion patterns based on the constraints and general economic conditions imposed by the investigator. The computer running time to execute a study is short and many system alternatives can be examined at a relatively low cost. The report contains a technical description of the code, list of input data requirements, program listing, sample execution, and parameter studies. (auth)

  7. Reliability of Sensors Based on Nanowire Networks When the Electrical Current is Allowed to Move in All Directions

    Directory of Open Access Journals (Sweden)

    Nader Ebrahimi

    2014-01-01

    Full Text Available Nanowire networks have great potential in many industrial applications, including batteries, electrical circuits, solar cells, and sensors. In this paper we focus on a specific hydrogen gas nanosensor whose sensing element is a network of palladium nanowires. The nanosensor is modeled using a square, equilateral triangle, and hexagonal lattice. We provide the reliability behavior of this nanosensor when the electrical current is allowed to move in all directions. Our findings reveal an improvement in reliability compared to the scenario where the electrical current could not move from right to left. We show this improvement both analytically and through simulation.

  8. STRUCTURAL FLUCTUATIONS, ELECTRICAL RESPONSE AND THE RELIABILITY OF NANOSTRUCTURES (FINAL REPORT)

    Energy Technology Data Exchange (ETDEWEB)

    Philip J. Rous; Ellen D. Williams; Michael S. Fuhrer

    2006-07-31

    The goal of the research supported by DOE-FG02-01ER45939 was to synthesize a number of experimental and theoretical approaches to understand the relationship between morphological fluctuations, the electrical response and the reliability (failure) of metallic nanostructures. The primary focus of our work was the study of metallic nanowires which we regard as prototypical of nanoscale interconnects. Our research plan has been to link together these materials properties and behaviors by understanding the phenomenon of, and the effects of electromigration at nanometer length scales. The thrust of our research has been founded on the concept that, for nanostructures where the surface-to-volume ratio is necessarily high, surface diffusion is the dominant mass transport mechanism that governs the fluctuations, electrical properties and failure modes of nanostructures. Our approach has been to develop experimental methods that permit the direct imaging of the electromagnetic distributions within nanostructures, their structural fluctuations and their electrical response. This experimental research is complemented by a parallel theoretical and computational program that describes the temporal evolution of nanostructures in response to current flow.

  9. RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    N. Ramirez

    2004-12-16

    A design requirement probability of 0.01 or less in a 4-hour period ensures that the nuclear heating, ventilation, and air-conditioning (HVAC) system in the primary confinement areas of the Dry Transfer Facilities (DTFs) and Fuel Handling Facility (FHF) is working during a Category 1 drop event involving commercial spent nuclear fuel (CSNF) assemblies (BSC 2004a , Section 5.1.1.48). This corresponds to an hourly HVAC failure rate of 2.5E-3 per hour or less, which is contributed to by two dominant causes: equipment failure and loss of electrical power. Meeting this minimum threshold ensures that a Category 1 initiating event followed by the failure of HVAC is a Category 2 event sequence. The two causes for the loss of electrical power include the loss of offsite power and the loss of onsite power distribution. Thus, in order to meet the threshold requirement aforementioned, the failure rate of mechanical equipment, loss of offsite power, and loss of onsite power distribution must be less than or equal to 2.5E-3 per hour for the nuclear HVAC system in the primary confinement areas of the DTFs and FHF. The loss of offsite power occurs at a frequency of 1.1E-5 per hour (BSC 2004a, Section 5.1.1.48). The purpose of this analysis is to determine the probability of occurrence of the unavailability of the nuclear HVAC system in the primary confinement areas of the DTFs and FHF due to loss of electrical power. In addition, this analysis provides insights on the contribution to the unavailability of the HVAC system due to equipment failure. The scope of this analysis is limited to finding the frequency of loss of electrical power to the nuclear HVAC system in the primary confinement areas of the DTFs and FHF.

  10. Reliability of fiber optic local and the other area networks (Poster Paper)

    Science.gov (United States)

    Grochowski, Lucjan

    1992-10-01

    Fault tolerance determines reliability of local, wide, and metropolitan area networks. Carried- out considerations are addressed to reliability evaluation of the classical, and the enhanced performance double rings, which are configurated according to ShuffleNet interconnection pattern realized by the use of wavelengths dependent signals. The considered multi-channel optical networks are modeled applying the Queuing Theory: the Continuous Time Markov Chains. Introduced models allow to determine in the data networks Mean Time to Failure, Data Throughput, and Time Delay. The results are implemented for performance simulation of advanced fiber optic data networks oriented towards High Speed Data Communications.

  11. Updated Value of Service Reliability Estimates for Electric Utility Customers in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Michael [Nexant Inc., Burlington, MA (United States); Schellenberg, Josh [Nexant Inc., Burlington, MA (United States); Blundell, Marshall [Nexant Inc., Burlington, MA (United States)

    2015-01-01

    This report updates the 2009 meta-analysis that provides estimates of the value of service reliability for electricity customers in the United States (U.S.). The meta-dataset now includes 34 different datasets from surveys fielded by 10 different utility companies between 1989 and 2012. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods, it was possible to integrate their results into a single meta-dataset describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the U.S. for industrial, commercial, and residential customers. This report focuses on the backwards stepwise selection process that was used to develop the final revised model for all customer classes. Across customer classes, the revised customer interruption cost model has improved significantly because it incorporates more data and does not include the many extraneous variables that were in the original specification from the 2009 meta-analysis. The backwards stepwise selection process led to a more parsimonious model that only included key variables, while still achieving comparable out-of-sample predictive performance. In turn, users of interruption cost estimation tools such as the Interruption Cost Estimate (ICE) Calculator will have less customer characteristics information to provide and the associated inputs page will be far less cumbersome. The upcoming new version of the ICE Calculator is anticipated to be released in 2015.

  12. Overview of RELCOMP, the reliability and cost model for electrical generation planning

    Energy Technology Data Exchange (ETDEWEB)

    Buehring, W.A.; Hub, K.A.; VanKuiken, J.C.

    1979-11-01

    RELCOMP is a system-planning tool that can be used to assess the reliability and economic performance of alternative expansion patterns of electric-utility-generating systems. Given input information such as capacity, forced outage rate, number of weeks of annual scheduled maintenance, and economic data for individual units along with the expected utility load characteristics, the nonoptimizing model calculates a system maintenance schedule, the loss-of-load probability, unserved demand for energy, mean time between system failures to meet the load, required reserve to meet a specified system-failure rate, expected energy generation from each unit, and system energy cost. Emergency interties and firm purchases can be included in the analysis. The calculation can be broken down into five distinct categories: maintenance scheduling, system reliability, capacity requirement, energy allocation, and energy cost. This brief description of the program is intended to serve as preliminary documentation for RELCOMP until a more-complete documentation is prepared. In addition to this documentation, a sample problem and a detailed input description are available from the authors.

  13. Reliability Indicators of Urban Electric Network Schemes for Supply of Second and Third Category Consumers

    Directory of Open Access Journals (Sweden)

    M. Korotkevich

    2012-01-01

    Full Text Available The paper considers two schemes of the urban distributive electric network for supply of the second and third category consumers for whom indicators of reliability have been determined.As for a network scheme of the 2nd category it has been determined that while installing low-oil and vacuum switches at a distributive point the most remote transformer substation has the highest non-availability  factor which is higher of the corresponding non-availability  factor of the nearest transformer substation by 1,21–1,23 fold  accordingly.As for a network scheme of the 3rd category consumers it has been obtained the data that reliability of consumers receiving supply from bus-bars of transformer substations with 0,38 kW voltage changes  significantly (by 1,2–1,9-fold while changing a breakpoint of the network with 10 kW voltage.

  14. Reliability centered maintenance (RCM: quantitative analysis of an induction electric furnace

    Directory of Open Access Journals (Sweden)

    Diego Santos Cerveira

    2015-06-01

    Full Text Available The purpose of this article is to define a maintenance strategy for an electric induction furnace, installed on a special steels Foundry. The research method was the quantitative modeling. The proposed method is based on Reliability-Centered Maintenance (RCM, applied to industrial equipment. Quantitative analysis of reliability, availability and maintainability were used as support the definition of the maintenance strategy of the equipment. For research, historical data were collected from time-to-repair (TTR and time between failures (TBF of the equipment under consideration. Supported by ProConf 2000 software, most appropriate distributions have been identified and modeled to TTR (lognormal and TBF (Weibull. With the results, availability of equipment Av = 98,18% and form factor g = 1 of the Weibull distribution were calculated. It was possible to find a position for the equipment on the bathtub curve, in the maturity phase and define the best maintenance strategy for this case, the predictive maintenance. Finally, the current strategy was discussed and development suggestions were presented to this strategy.

  15. Foreseeing the reliability indexes of two-cascade thermo-electric cooling device in the mode of ΔTmax

    Directory of Open Access Journals (Sweden)

    Zaykov V. P.

    2009-08-01

    Full Text Available There has been offered a correlation model of reliability indexes for two-cascade TED of set design with basic meaningful parameters at successive electric connection of cascades. The model allows to estimate both cooling possibilities and reliability indexes of the TED of set design, working in the mode of ΔTmax, taking into account the relation of amount of thermo-couples in cascades and temperature dependence of parameters. The offered approach allows to forecast the reliability indexes to the TED of set design under various conditions of exploitation and to conduct the optimized planning of REA with the use of two-cascade TED.

  16. Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity

    Energy Technology Data Exchange (ETDEWEB)

    Schouman, Thomas, E-mail: thomas.schouman@psl.aphp.fr [Service of Oral and Maxillofacial Surgery, Department of Surgery, University Hospital and Faculty of Medicine of Geneva, 1211 Genève (Switzerland); Courvoisier, Delphine S., E-mail: delphine.courvoisier@hcuge.ch [Biostatistician - Service of Clinical Epidemiology, University Hospital and Faculty of Medicine of Geneva 1211 Genève (Switzerland); Imholz, Benoit, E-mail: benoit.imholz@hcuge.ch [Service of Oral and Maxillofacial Surgery, Department of Surgery, University Hospital and Faculty of Medicine of Geneva, 1211 Genève (Switzerland); Van Issum, Christopher, E-mail: christopher.vanissum@hcuge.ch [Service of Ophthalmology, University Hospital and Faculty of Medicine of Geneva, 1211 Genève (Switzerland); Scolozzi, Paolo, E-mail: paolo.scolozzi@hcuge.ch [Service of Oral and Maxillofacial Surgery, Department of Surgery, University Hospital and Faculty of Medicine of Geneva, 1211 Genève (Switzerland)

    2012-09-15

    Objective: To evaluate the reliability, accuracy and rapidity of a specific computational method for assessing the orbital floor fracture area on a CT scan. Method: A computer assessment of the area of the fracture, as well as that of the total orbital floor, was determined on CT scans taken from ten patients. The ratio of the fracture's area to the orbital floor area was also calculated. The test–retest precision of measurement calculations was estimated using the Intraclass Correlation Coefficient (ICC) and Dahlberg's formula to assess the agreement across observers and across measures. The time needed for the complete assessment was also evaluated. Results: The Intraclass Correlation Coefficient across observers was 0.92 [0.85;0.96], and the precision of the measures across observers was 4.9%, according to Dahlberg's formula .The mean time needed to make one measurement was 2 min and 39 s (range, 1 min and 32 s to 4 min and 37 s). Conclusion: This study demonstrated that (1) the area of the orbital floor fracture can be rapidly and reliably assessed by using a specific computer system directly on CT scan images; (2) this method has the potential of being routinely used to standardize the post-traumatic evaluation of orbital fractures.

  17. Consortium for Electric Reliability Technology Solutions Grid of the Future White Paper on Review of Recent Reliability Issues and Systems Events

    Energy Technology Data Exchange (ETDEWEB)

    Hauer, John F.; Dagle, Jeffery E.

    1999-12-01

    This report is one of six reports developed under the U.S. Department of Energy (DOE) program in Power System Integration and Reliability (PSIR). The objective of this report is to review, analyze, and evaluate critical reliability issues demonstrated by recent disturbance events in the North America power system. Eleven major disturbances are examined, most occurring in this decade. The strategic challenge is that the pattern of technical need has persisted for a long period of time. For more than a decade, anticipation of market deregulation has been a major disincentive to new investments in system capacity. It has also inspired reduced maintenance of existing assets. A massive infusion of better technology is emerging as the final option to continue reliable electrical services. If an investment in better technology will not be made in a timely manner, then North America should plan its adjustments to a very different level of electrical service. It is apparent that technical operations staff among the utilities can be very effective at marshaling their forces in the immediate aftermath of a system emergency, and that serious disturbances often lead to improved mechanisms for coordinated operation. It is not at all apparent that such efforts can be sustained through voluntary reliability organizations in which utility personnel external to those organizations do most of the technical work. The eastern interconnection shows several situations in which much of the technical support has migrated from the utilities to the Independent System Operator (ISO), and the ISO staffs or shares staff with the regional reliability council. This process may be a natural and very positive consequence of utility restructuring. If so, the process should be expedited in regions where it is less advanced.

  18. Site-specific landslide assessment in Alpine area using a reliable integrated monitoring system

    Science.gov (United States)

    Romeo, Saverio; Di Matteo, Lucio; Kieffer, Daniel Scott

    2016-04-01

    Rockfalls are one of major cause of landslide fatalities around the world. The present work discusses the reliability of integrated monitoring of displacements in a rockfall within the Alpine region (Salzburg Land - Austria), taking into account also the effect of the ongoing climate change. Due to the unpredictability of the frequency and magnitude, that threatens human lives and infrastructure, frequently it is necessary to implement an efficient monitoring system. For this reason, during the last decades, integrated monitoring systems of unstable slopes were widely developed and used (e.g., extensometers, cameras, remote sensing, etc.). In this framework, Remote Sensing techniques, such as GBInSAR technique (Groung-Based Interferometric Synthetic Aperture Radar), have emerged as efficient and powerful tools for deformation monitoring. GBInSAR measurements can be useful to achieve an early warning system using surface deformation parameters as ground displacement or inverse velocity (for semi-empirical forecasting methods). In order to check the reliability of GBInSAR and to monitor the evolution of landslide, it is very important to integrate different techniques. Indeed, a multi-instrumental approach is essential to investigate movements both in surface and in depth and the use of different monitoring techniques allows to perform a cross analysis of the data and to minimize errors, to check the data quality and to improve the monitoring system. During 2013, an intense and complete monitoring campaign has been conducted on the Ingelsberg landslide. By analyzing both historical temperature series (HISTALP) recorded during the last century and those from local weather stations, temperature values (Autumn-Winter, Winter and Spring) are clearly increased in Bad Hofgastein area as well as in Alpine region. As consequence, in the last decades the rockfall events have been shifted from spring to summer due to warmer winters. It is interesting to point out that

  19. Intraoperative direct electrical stimulations of central nervous system during surgery of gliomas near eloquent areas

    Directory of Open Access Journals (Sweden)

    WANG Wei-min

    2012-12-01

    Full Text Available Objective To report our experiences of direct cortical stimulation in surgery of gliomas located in eloquent areas. Methods Clinical data of 157 patients with gliomas underwent awake craniotomy with the direct electrical stimulation for functional mapping of the eloquent areas were analysed retrospectively. Results Negative cortical stimulation was found in 4 patients, and positive cortical stimulation was achieved in 153 patients (97.45% . Four hundred and ninty -six cortical sites in 139 patients were detected for motor response by direct electrical stimulation, 70 sites in 21 patients for sensory, 112 sites in 91 patients for language (such as counting and naming. The positive areas of counting disturbance were mainly seen at the lower part of left precentral gyri operculum of left inferior frontal gyri, triangular part of left inferior frontal gyri, posterior part of left middle frontal gyri, and posterior part of left superior frontal gyri. Postoperative MRI showed 92 patients (58.60% achieved total resection, 55 cases (35.03% subtotal and 10 cases (6.37% partial. One hundred and ten patients (70.06% were diagnosed as having low grade glimas, including 71 cases of astrocytoma, 26 cases of oligodendroglioma, and 13 cases of mixed astro ? oligodendroglioma, 47 patients (29.94% were high grade gliomas, including 19 cases of glioblastoma, 15 cases of anaplastic astrocytoma, and 13 cases of anaplastic oligodendroglioma. After operation 53 patients (33.76% occurred transient postoperative paralysis, 39 patients (24.84% transient language disturbance and 4 patients (2.55% permanent neurological deficits. Conclusion Intraoperative direct electrical stimulation is a reliable, precise and safety method for functional mapping of the eloquent areas. This technique allows us to achieve 'maximal safety resection' in glioma surgery.

  20. Sustainable electricity generation by solar pv/diesel hybrid system without storage for off grids areas

    Science.gov (United States)

    Azoumah, Y.; Yamegueu, D.; Py, X.

    2012-02-01

    Access to energy is known as a key issue for poverty reduction. The electrification rate of sub Saharan countries is one of the lowest among the developing countries. However this part of the world has natural energy resources that could help raising its access to energy, then its economic development. An original "flexy energy" concept of hybrid solar pv/diesel/biofuel power plant, without battery storage, is developed in order to not only make access to energy possible for rural and peri-urban populations in Africa (by reducing the electricity generation cost) but also to make the electricity production sustainable in these areas. Some experimental results conducted on this concept prototype show that the sizing of a pv/diesel hybrid system by taking into account the solar radiation and the load/demand profile of a typical area may lead the diesel generator to operate near its optimal point (70-90 % of its nominal power). Results also show that for a reliability of a PV/diesel hybrid system, the rated power of the diesel generator should be equal to the peak load. By the way, it has been verified through this study that the functioning of a pv/Diesel hybrid system is efficient for higher load and higher solar radiation.

  1. Independent transmission system operators and their role in maintaining reliability in a restructured electric power industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This report summarizes the current status of proposals to form Independent System Operators (ISOs) to operate high-voltage transmission systems in the United States and reviews their potential role in maintaining bulk power system reliability. As background information, the likely new industry structure, nature of deregulated markets, and institutional framework for bulk power system reliability are reviewed. The report identifies issues related to the formation of ISOs and their roles in markets and in reliability, and describes potential policy directions for encouraging the formation of effective ISOs and ensuring bulk system reliability. Two appendices are provided, which address: (1) system operation arrangements in other countries, and (2) summaries of regional U.S. ISO proposals.

  2. 基于可靠性需求的电力客户细分和可靠性价值评估方法%Assessment Method for Subdivision of Electric Power Customers and Reliability Value Based on Reliability Demand

    Institute of Scientific and Technical Information of China (English)

    蔡政权; 刘至锋; 管霖; 曾毅豪

    2015-01-01

    从电力用户角度提出可靠性提升的直接经济价值、用户体验价值和社会价值的定义及其计算模型,建立区域供电可靠性需求评估框架,介绍具有较高可靠性价值的7类用户及其特征采集和可靠性价值分类评估算法。针对具有较强主观性的用户体验价值和社会价值的定量评估,提出一种改进层次分析(analytical hierarchy process,AHP)法,并通过区域可靠性需求评价应用实例验证该方法的有效性。该算法既可用于供电企业客观评估不同供电区域的客户供电可靠性需求,也可为实施可靠性电价后的市场需求分析和预测提供技术支撑。%From the point of electric power customers,concepts of direct economic value,customer experience value and so-cial value of reliability promotion and calculation models were proposed,assessment frame for regional power supply reliabil-ity demand was established,in addition,seven kinds customers of higher reliabilities and related characteristic acquisition and assessment algorithm for reliability value classification were introduced.Aiming at quantity assessment on stronger sub-jective customer experience value and social value,a kind of improved analytical hierarchy process(AHP)method was pro-posed and by means of application example of evaluation on regional reliability demand,effectiveness of this method was verified.This algorithm could be applied in objectively assessing customer power supply reliability demands in different pow-er supply areas as well as providing technical support for market demand analysis and prediction after implementing reliabili-ty power price.

  3. Towards Reliable and Energy-Efficient Incremental Cooperative Communication for Wireless Body Area Networks.

    Science.gov (United States)

    Yousaf, Sidrah; Javaid, Nadeem; Qasim, Umar; Alrajeh, Nabil; Khan, Zahoor Ali; Ahmed, Mansoor

    2016-01-01

    In this study, we analyse incremental cooperative communication for wireless body area networks (WBANs) with different numbers of relays. Energy efficiency (EE) and the packet error rate (PER) are investigated for different schemes. We propose a new cooperative communication scheme with three-stage relaying and compare it to existing schemes. Our proposed scheme provides reliable communication with less PER at the cost of surplus energy consumption. Analytical expressions for the EE of the proposed three-stage cooperative communication scheme are also derived, taking into account the effect of PER. Later on, the proposed three-stage incremental cooperation is implemented in a network layer protocol; enhanced incremental cooperative critical data transmission in emergencies for static WBANs (EInCo-CEStat). Extensive simulations are conducted to validate the proposed scheme. Results of incremental relay-based cooperative communication protocols are compared to two existing cooperative routing protocols: cooperative critical data transmission in emergencies for static WBANs (Co-CEStat) and InCo-CEStat. It is observed from the simulation results that incremental relay-based cooperation is more energy efficient than the existing conventional cooperation protocol, Co-CEStat. The results also reveal that EInCo-CEStat proves to be more reliable with less PER and higher throughput than both of the counterpart protocols. However, InCo-CEStat has less throughput with a greater stability period and network lifetime. Due to the availability of more redundant links, EInCo-CEStat achieves a reduced packet drop rate at the cost of increased energy consumption.

  4. [Preoperative direct cortical and sub-cortical electric stimulation during cerebral surgery in functional areas].

    Science.gov (United States)

    Duffau, H; Capelle, L; Sichez, J P; Bitar, A; Faillot, T; Arthuis, F; Van Effenterre, R; Fohanno, D

    1999-09-01

    Indications of surgical treatment for lesions in functional cerebral areas depend on the ratio between the definitive neurological deficit and the beneficial effect of resection. Detection of eloquent cortex is difficult because of important individual variability. Peroperative direct cortical and subcortical electrical stimulations (DCS) provide the most precise and reliable method currently available allowing identification and preservation of neurons essential for motricity, sensitivity++ and language. We report our preliminary experience with DCS in surgery of intracerebral infiltrative tumors with a consecutive series of 15 patients operated from November 96 through September 97 in our institution. Presenting symptoms in the 15 patients (8 males, 7 females, mean age 43 years) were seizures in 11 cases (73%) and neurological deficit in 4 cases (27%). Clinical examination was normal in 11 patients and revealed hemiparesia in 4. Magnetic resonance imaging (MRI) with three-dimensional reconstruction showed a precentral tumor in 10 cases, central lesion in one patient, postcentral lesion in two cases, right insular tumor (non-dominant hemisphere) in one case. All patients underwent surgical resection using DCS with detection in 13 cases of motor cortex and subcortical pathways under genera anesthesia, in one case of somatosensory area under local anesthesia, and in one case of language areas also under local anesthesia. The tumor was recurrent in two patients had been operated earlier but without DCS. Resection, verified by postoperative MRI, was total in 12 cases (80%) and estimated at 80% in 3 patients. Histological examination revealed an infiltrative glioma in 12 cases (8 low grade astrocytomas, 3 low grade oligodendrogliomas, and one anaplastic oligodendroglioma), and metastases in 3 cases. Eight patients had no postoperative deficit, while the other 7 patients were impaired, with, in all cases except one, complete recovery in 15 days to 2 months. Direct

  5. Graphene-coated atomic force microscope tips for reliable nanoscale electrical characterization.

    Science.gov (United States)

    Lanza, M; Bayerl, A; Gao, T; Porti, M; Nafria, M; Jing, G Y; Zhang, Y F; Liu, Z F; Duan, H L

    2013-03-13

    Graphene single-layer films are grown by chemical vapor deposition and transferred onto commercially available conductive tips for atomic force microscopy. Graphene-coated tips are much more resistant to both high currents and frictions than commercially available, metal-varnished, conductive atomic force microscopy tips, leading to much larger lifetimes and more reliable imaging due to a lower tip-sample interaction.

  6. Reliable prediction of electric spark sensitivity of nitramines: a general correlation with detonation pressure.

    Science.gov (United States)

    Keshavarz, Mohammad Hossein; Pouretedal, Hamid Reza; Semnani, Abolfazl

    2009-08-15

    For nitramines, a general correlation has been introduced to predict electric spark sensitivity through detonation pressure. New method uses maximum obtainable detonation pressure as a fundamental relation so that it can be corrected for some nitramines which have some specific molecular structure. There is no need to use crystal density and heat of formation of nitramine explosives for predicting detonation pressure and electric spark sensitivity. The predicted electric spark sensitivities are compared with calculated results on the basis of quantum mechanical computations for some nitramines that latter can be applied. The root mean square (rms) deviations from experiment for new method and the predicted results of complicated quantum mechanical method are 1.18 and 3.49J, respectively.

  7. Did Geomagnetic Activity Challenge Electric Power Reliability During Solar Cycle 23? Evidence from the PJM Regional Transmission Organization in North America

    Science.gov (United States)

    Forbes, Kevin F.; Cyr, Chris St

    2012-01-01

    During solar cycle 22, a very intense geomagnetic storm on 13 March 1989 contributed to the collapse of the Hydro-Quebec power system in Canada. This event clearly demonstrated that geomagnetic storms have the potential to lead to blackouts. This paper addresses whether geomagnetic activity challenged power system reliability during solar cycle 23. Operations by PJM Interconnection, LLC (hereafter PJM), a regional transmission organization in North America, are examined over the period 1 April 2002 through 30 April 2004. During this time PJM coordinated the movement of wholesale electricity in all or parts of Delaware, Maryland, New Jersey, Ohio, Pennsylvania, Virginia, West Virginia, and the District of Columbia in the United States. We examine the relationship between a proxy of geomagnetically induced currents (GICs) and a metric of challenged reliability. In this study, GICs are proxied using magnetometer data from a geomagnetic observatory located just outside the PJM control area. The metric of challenged reliability is the incidence of out-of-economic-merit order dispatching due to adverse reactive power conditions. The statistical methods employed make it possible to disentangle the effects of GICs on power system operations from purely terrestrial factors. The results of the analysis indicate that geomagnetic activity can significantly increase the likelihood that the system operator will dispatch generating units based on system stability considerations rather than economic merit.

  8. Evaluation of the electrical contact area in contact-mode scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Celano, Umberto, E-mail: celano@imec.be, E-mail: u.celano@gmail.com; Chintala, Ravi Chandra; Vandervorst, Wilfried [IMEC, Kapeldreef 75, B-3001 Heverlee (Leuven) (Belgium); Department of Physics and Astronomy (IKS), KU Leuven, Celestijnenlaan 200D, 3001 Leuven (Belgium); Hantschel, Thomas; Giammaria, Guido; Conard, Thierry; Bender, Hugo [IMEC, Kapeldreef 75, B-3001 Heverlee (Leuven) (Belgium)

    2015-06-07

    The tunneling current through an atomic force microscopy (AFM) tip is used to evaluate the effective electrical contact area, which exists between tip and sample in contact-AFM electrical measurements. A simple procedure for the evaluation of the effective electrical contact area is described using conductive atomic force microscopy (C-AFM) in combination with a thin dielectric. We characterize the electrical contact area for coated metal and doped-diamond tips operated at low force (<200 nN) in contact mode. In both cases, we observe that only a small fraction (<10 nm{sup 2}) of the physical contact (∼100 nm{sup 2}) is effectively contributing to the transport phenomena. Assuming this reduced area is confined to the central area of the physical contact, these results explain the sub-10 nm electrical resolution observed in C-AFM measurements.

  9. Development of a database for use in electric power utilities in the electric power distribution area; Desenvolvimento de um banco de dados para uso em concessionarias de energia eletrica na area de distribuicao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Sobral, Marcos Alexandre Barreiros

    1996-07-01

    The electric energy distribution system dimension together with the involved diverging elements. requires a constant updated information system. The dynamics and the reliability of the information implies in the use of modern technology, as well as data updating and control. There is a constant need of improving the utilities information system and its lack may put into risk not only the quality of the services but also consumer satisfaction. Utilities technical systems should therefore follow this need allowing for a quick response needed in order to keep the system under control and consequently to maintain the quality of the services. This work proposes a basic information technology model for technical areas and for an electric utility that can be applied to manage any data bank at any platform. To have it demonstrated, a Visual Basic application was developed applying X base data structure, which shows the use of alpha numerical data with G S (Geographic Information System). (author)

  10. Reliability of the electric power network in The World; Betrouwbaarheid essentieel voor elektriciteitsnet The World

    Energy Technology Data Exchange (ETDEWEB)

    Roggen, M. (ed.)

    2007-04-15

    Offshore the coast of Dubai a group of artificial island will be built with houses for which the energy supply comes from the main land. KEMA developed a ring-shaped redundant electricity network which will have 300 underwater cable junctions. [Dutch] Voor de kust van Dubai verrijst een kunstmatige eilandengroep met woningen waarvoor de energievoorziening van het vasteland moet komen. Speciaal daarvoor ontwierp KEMA een ring- en lusvormig redundant elektriciteitsnet dat zich onder water vertakt in 300 kabelaansluitingen.

  11. Life cycle costs of electric industrial drives. Reliability and energy consumption are decisive cost factors. Life-Cycle Costs elektrischer Industrieantriebe. Zuverlaessigkeit und Energieverbrauch als entscheidende Kostenfaktoren

    Energy Technology Data Exchange (ETDEWEB)

    Bieniek, K. (BASF AG, Ludwigshafen (Germany))

    1999-06-01

    In the case of electric drives for the chemical industry, the purchase cost is only a fraction of the life cycle cost. The main criteria for engine assessment are reliability and energy consumption resp. performance. After the issuing of the US Energy Policy Act, the EC is discussion energy savings with the aid of high-performance electric motors.

  12. Electricity supply to rural areas of Argentina. Manuscript report No. 303e

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    This document contains reports of the first and second stages of the RETAIN (Rural Energy Technology Assessment and Innovation Network) project in the Misiones area in northern Argentina. The study analyzes the problems of meeting the electrical energy needs of the rural household sector in regions of the Third World to develop an analytical method that facilitates decision-making in projects of electrical supply to rural areas with a low level of development. The study describes the socio-economic and energy levels of the area; analyzes the present and future electric energy requirements and describes the energy resources; evaluates supply alternatives and costs; and describes the plans of the RETAIN project.

  13. Ionizing radiation effects on electrical and reliability characteristics of sputtered Ta2O5/Si interface

    Science.gov (United States)

    Rao, Ashwath; Verma, Ankita; Singh, B. R.

    2015-06-01

    This paper describes the effect of ionizing radiation on the interface properties of Al/Ta2O5/Si metal oxide semiconductor (MOS) capacitors using capacitance-voltage (C-V) and current-voltage (I-V) characteristics. The devices were irradiated with X-rays at different doses ranging from 100 rad to 1 Mrad. The leakage behavior, which is an important parameter for memory applications of Al/Ta2O5/Si MOS capacitors, along with interface properties such as effective oxide charges and interface trap density with and without irradiation has been investigated. Lower accumulation capacitance and shift in flat band voltage toward negative value were observed in annealed devices after exposure to radiation. The increase in interfacial oxide layer thickness after irradiation was confirmed by Rutherford Back Scattering measurement. The effect of post-deposition annealing on the electrical behavior of Ta2O5 MOS capacitors was also investigated. Improved electrical and interface properties were obtained for samples deposited in N2 ambient. The density of interface trap states (Dit) at Ta2O5/Si interface sputtered in pure argon ambient was higher compared to samples reactively sputtered in nitrogen-containing plasma. Our results show that reactive sputtering in nitrogen-containing plasma is a promising approach to improve the radiation hardness of Ta2O5/Si MOS devices.

  14. Final Report to the National Energy Technology Laboratory on FY09-FY13 Cooperative Research with the Consortium for Electric Reliability Technology Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vittal, Vijay [Arizona State Univ., Mesa, AZ (United States)

    2015-11-04

    The Consortium for Electric Reliability Technology Solutions (CERTS) was formed in 1999 in response to a call from U.S. Congress to restart a federal transmission reliability R&D program to address concerns about the reliability of the U.S. electric power grid. CERTS is a partnership between industry, universities, national laboratories, and government agencies. It researches, develops, and disseminates new methods, tools, and technologies to protect and enhance the reliability of the U.S. electric power system and the efficiency of competitive electricity markets. It is funded by the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE). This report provides an overview of PSERC and CERTS, of the overall objectives and scope of the research, a summary of the major research accomplishments, highlights of the work done under the various elements of the NETL cooperative agreement, and brief reports written by the PSERC researchers on their accomplishments, including research results, publications, and software tools.

  15. Using solar-powered refrigeration for vaccine storage where other sources of reliable electricity are inadequate or costly.

    Science.gov (United States)

    McCarney, Steve; Robertson, Joanie; Arnaud, Juliette; Lorenson, Kristina; Lloyd, John

    2013-12-09

    Large areas of many developing countries have no grid electricity. This is a serious challenge that threatens the continuity of the vaccine cold chain. The main alternatives to electrically powered refrigerators available for many years--kerosene- and gas-driven refrigerators--are plagued by problems with gas supply interruptions, low efficiency, poor temperature control, and frequent maintenance needs. There are currently no kerosene- or gas-driven refrigerators that qualify under the minimum standards established by the World Health Organization (WHO) Performance, Quality, and Safety (PQS) system. Solar refrigeration was a promising development in the early 1980s, providing an alternative to absorption technology to meet cold chain needs in remote areas. Devices generally had strong laboratory performance data; however, experience in the field over the years has been mixed. Traditional solar refrigerators relied on relatively expensive battery systems, which have demonstrated short lives compared to the refrigerator. There are now alternatives to the battery-based systems and a clear understanding that solar refrigerator systems need to be designed, installed, and maintained by technicians with the necessary knowledge and training. Thus, the technology is now poised to be the refrigeration method of choice for the cold chain in areas with no electricity or extremely unreliable electricity (less than 4h per average day) and sufficient sunlight. This paper highlights some lessons learned with solar-powered refrigeration, and discusses some critical factors for successful introduction of solar units into immunization programs in the future including: •Sustainable financing mechanisms and incentives for health workers and technicians are in place to support long-term maintenance, repair, and replacement parts. •System design is carried out by qualified solar refrigerator professionals taking into account the conditions at installation sites. •Installation and

  16. Electric Vehicles Parking (EVP) Sitting Considering GIS Information and the Extent of Urban Areas

    OpenAIRE

    Mohammad R. Aghaebrahimi; Mahdi Tourani; Mohammad M. Ghasemipour

    2015-01-01

    energy resources, such as wind and solar, are increased. Also, the use of Electric Vehicles (EV) and Plug-in Hybrid Electric Vehicles (PHEV), known as V2G, is under development. Due to the widespread use of these vehicles in the near future, Electric Vehicles Parking (EVP) is considered as a source of Distributed Generation (DG) and Electric Energy Storage. The location of parking lot is important for power utilities to reduce power losses, and to municipalities of the urban areas from constr...

  17. Reliability Information Analysis Center 1st Quarter 2007, Technical Area Task (TAT) Report

    Science.gov (United States)

    2007-02-05

    07 planning conference 14 Dec 06 II Marine Expeditionary Force (MEF) meeting with Major Smith 14 Dec 06 Gulf of Mexico Tyndall Air Force Base Missile...Restructured action item spreadsheet " Reviewed the following storyboards (functional flow, graphics and text): 1. 050101 Main Rotor System components 2... storyboards (functional flow, graphics, and text): o 050101 Main Rotor System components. Reliability Information Analysis Center 6000 Flanagan Road

  18. Electricity demand profile with high penetration of heat pumps in Nordic area

    DEFF Research Database (Denmark)

    Liu, Zhaoxi; Wu, Qiuwei; Nielsen, Arne Hejde

    2013-01-01

    This paper presents the heat pump (HP) demand profile with high HP penetration in the Nordic area in order to achieve the carbon neutrality power system. The calculation method in the European Standard EN14825 was used to estimate the HP electricity demand profile. The study results show there wi......This paper presents the heat pump (HP) demand profile with high HP penetration in the Nordic area in order to achieve the carbon neutrality power system. The calculation method in the European Standard EN14825 was used to estimate the HP electricity demand profile. The study results show...... there will be high power demand from HPs and the selection of supplemental heating for heat pumps has a big impact on the peak electrical power load of heating. The study in this paper gives an estimate of the scale of the electricity demand with high penetration of heat pumps in the Nordic area....

  19. Estimation of reliability of seismic and electromagnetic monitoring in seismic active areas by diffraction tomography

    OpenAIRE

    Troyan, V. N.; Kiselev, Yu. V.

    2001-01-01

    This paper presents the algorithms and results of the numerical simulation of the solution of a 2-D inverse problem on the restoration of seismic parameters and electrical conductivity of local inhomogeneities by the diffraction tomography method based upon the first order Born approximation. The direct problems for the Lame and Maxwell equations are solved by the finite difference method. Restoration of inhomogeneities which are not ...

  20. Analysis of Reliability of Electrical Automation Control Equipment%关于电气自动化控制设备可靠性问题的分析

    Institute of Scientific and Technical Information of China (English)

    张英杰

    2016-01-01

    The author analyzes and researches on some problems related to reliability of the electrical automation equipment based on years of practical experience and professional knowledge and skills,mainly including significance of doing a good job of electrical automation equipment reliability analysis,problems in the analysis process of electrical automation control equipment reliability,and measures of solving the problems in electrical automation control equipment reliability analysis,aiming to offer ref-erence and promote better development of Chinaˊs electrical industry.%笔者结合自身多年的实践经验和所掌握的专业知识和技能,就电气自动化设备可靠性的相关问题进行了分析和研究,主要包括做好电气自动化设备可靠性分析工作的重要意义、电气自动化控制设备可靠性分析过程中存在的问题、解决电气自动化控制设备可靠性分析中存在问题及措施三个基础部分,希望能够起到一定参考和借鉴的作用,促进我国的电气行业实现更快更好的发展。

  1. Estimation of reliability of seismic and electromagnetic monitoring in seismic active areas by diffraction tomography

    Directory of Open Access Journals (Sweden)

    V. N. Troyan

    2001-01-01

    Full Text Available This paper presents the algorithms and results of the numerical simulation of the solution of a 2-D inverse problem on the restoration of seismic parameters and electrical conductivity of local inhomogeneities by the diffraction tomography method based upon the first order Born approximation. The direct problems for the Lame and Maxwell equations are solved by the finite difference method. Restoration of inhomogeneities which are not very weak is implemented with the use of a small number of receivers (source-receiver pairs.

  2. Electric Vehicles Parking (EVP Sitting Considering GIS Information and the Extent of Urban Areas

    Directory of Open Access Journals (Sweden)

    Mohammad R. Aghaebrahimi

    2015-03-01

    Full Text Available energy resources, such as wind and solar, are increased. Also, the use of Electric Vehicles (EV and Plug-in Hybrid Electric Vehicles (PHEV, known as V2G, is under development. Due to the widespread use of these vehicles in the near future, Electric Vehicles Parking (EVP is considered as a source of Distributed Generation (DG and Electric Energy Storage. The location of parking lot is important for power utilities to reduce power losses, and to municipalities of the urban areas from construction point of view. In this paper, sitting of EVP considering GIS information and the extent of urban areas will be discussed for rapid determination of parking locations using different evolutionary algorithms. The goal is to reduce the candidate locations, to analyze and to compare the performance of these algorithms as well as increasing the satisfaction of power utilities and municipalities.

  3. Autonomous docking based on infrared system for electric vehicle charging in urban areas.

    Science.gov (United States)

    Pérez, Joshué; Nashashibi, Fawzi; Lefaudeux, Benjamin; Resende, Paulo; Pollard, Evangeline

    2013-02-21

    Electric vehicles are progressively introduced in urban areas, because of their ability to reduce air pollution, fuel consumption and noise nuisance. Nowadays, some big cities are launching the first electric car-sharing projects to clear traffic jams and enhance urban mobility, as an alternative to the classic public transportation systems. However, there are still some problems to be solved related to energy storage, electric charging and autonomy. In this paper, we present an autonomous docking system for electric vehicles recharging based on an embarked infrared camera performing infrared beacons detection installed in the infrastructure. A visual servoing system coupled with an automatic controller allows the vehicle to dock accurately to the recharging booth in a street parking area. The results show good behavior of the implemented system, which is currently deployed as a real prototype system in the city of Paris.

  4. Autonomous Docking Based on Infrared System for Electric Vehicle Charging in Urban Areas

    Directory of Open Access Journals (Sweden)

    Joshué Pérez

    2013-02-01

    Full Text Available Electric vehicles are progressively introduced in urban areas, because of their ability to reduce air pollution, fuel consumption and noise nuisance. Nowadays, some big cities are launching the first electric car-sharing projects to clear traffic jams and enhance urban mobility, as an alternative to the classic public transportation systems. However, there are still some problems to be solved related to energy storage, electric charging and autonomy. In this paper, we present an autonomous docking system for electric vehicles recharging based on an embarked infrared camera performing infrared beacons detection installed in the infrastructure. A visual servoing system coupled with an automatic controller allows the vehicle to dock accurately to the recharging booth in a street parking area. The results show good behavior of the implemented system, which is currently deployed as a real prototype system in the city of Paris.

  5. Using Vertical Electrical Soundings for Characterizing Hydrogeological and Tectonic Settings in Deir El-Adas Area, Yarmouk Basin, Syria

    Science.gov (United States)

    Al-Fares, Walid

    2016-06-01

    The present study is aimed at characterizing the subsurface geological and tectonic structure in Deir El-Adas area, by using Vertical Electrical Sounding survey (VES) and hydrogeological investigations, in order to determine the causes of the failure for the majority of the wells drilled in the area. The survey data was treated in three different approaches including direct VES inversion, pseudo-2D method and horizontal profiling, in order to maximize the reliability of the data interpretation. The results revealed the presence of a local faulted anticline structure at the top of the Paleogene formation, underneath the basaltic outcrops where Deir El-Adas village is situated. The appearance of this subsurface anticline structure has complicated the local hydro-geological situation, and most likely led to limitation of the groundwater recharge in the area. Moreover, the performed piezometric and discharge maps indicated the presence of a notable groundwater watershed, in addition to feeble water productivity of the wells drilled adjacent to Deir El-Adas, mostly related to the subsurface geological and tectonic settings in the area.

  6. Residual Mix Calculation at the Heart of Reliable Electricity Disclosure in Europe—A Case Study on the Effect of the RE-DISS Project

    Directory of Open Access Journals (Sweden)

    Markus Klimscheffskij

    2015-05-01

    Full Text Available In the EU, electricity suppliers are obliged to disclose to their customers the energy origin and environmental impacts of sold electricity. To this end, guarantees of origin (GOs are used to explicitly track electricity generation attributes to individual electricity consumers. When part of a reliable electricity disclosure system, GOs deliver an important means for consumers to participate in the support of renewable power. In order to be considered reliable, GOs require the support of an implicit disclosure system, a residual mix, which prevents once explicitly tracked attributes from being double counted in a default energy mix. This article outlines the key problems in implicit electricity disclosure: (1 uncorrected generation statistics used for implicit disclosure; (2 contract-based tracking; (3 uncoordinated calculation within Europe; (4 overlapping regions for implicit disclosure; (5 active GOs. The improvements achieved during the RE-DISS project (04/2010-10/2012 with regard to these problems have reduced the total implicit disclosure error by 168 TWh and double counting of renewable generation attributes by 70 TWh, in 16 selected countries. Quantitatively, largest individual improvements were achieved in Norway, Germany and Italy. Within the 16 countries, a total disclosure error of 75 TWh and double counting of renewable generation attributes of 36 TWh still reside after the end of the project on national level. Regarding the residual mix calculation methodology, the article justifies the implementation of a shifted transaction-based method instead of a production year-based method.

  7. Utility of Big Area Additive Manufacturing (BAAM) For The Rapid Manufacture of Customized Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J [ORNL

    2015-08-01

    This Oak Ridge National Laboratory (ORNL) Manufacturing Development Facility (MDF) technical collaboration project was conducted in two phases as a CRADA with Local Motors Inc. Phase 1 was previously reported as Advanced Manufacturing of Complex Cyber Mechanical Devices through Community Engagement and Micro-manufacturing and demonstrated the integration of components onto a prototype body part for a vehicle. Phase 2 was reported as Utility of Big Area Additive Manufacturing (BAAM) for the Rapid Manufacture of Customized Electric Vehicles and demonstrated the high profile live printing of an all-electric vehicle using ONRL s Big Area Additive Manufacturing (BAAM) technology. This demonstration generated considerable national attention and successfully demonstrated the capabilities of the BAAM system as developed by ORNL and Cincinnati, Inc. and the feasibility of additive manufacturing of a full scale electric vehicle as envisioned by the CRADA partner Local Motors, Inc.

  8. [Role of acetylcholine in coordination od spontaneous electrical activity of various areas of the rat uterus].

    Science.gov (United States)

    Kazarian, K V; Unanian, N G; Akopian, R R

    2012-01-01

    Spontaneous electrical activity of myometrium was studied in areas of the uterine corpus, zone of its connection with uterine tube and cervix at intravenous administration of various acetylcholine concentrations. Under these conditions, changes of the frequency and amplitude characteristics of rhythmogenesis were studied both separately and in their combined active state. The presence of 10(-3) M acetylcholine in the animal blood creates the most optimal conditions for synchronization and coordination of activities of all studied uterus areas.

  9. High-resolution imaging of expertise reveals reliable object selectivity in the fusiform face area related to perceptual performance.

    Science.gov (United States)

    McGugin, Rankin Williams; Gatenby, J Christopher; Gore, John C; Gauthier, Isabel

    2012-10-16

    The fusiform face area (FFA) is a region of human cortex that responds selectively to faces, but whether it supports a more general function relevant for perceptual expertise is debated. Although both faces and objects of expertise engage many brain areas, the FFA remains the focus of the strongest modular claims and the clearest predictions about expertise. Functional MRI studies at standard-resolution (SR-fMRI) have found responses in the FFA for nonface objects of expertise, but high-resolution fMRI (HR-fMRI) in the FFA [Grill-Spector K, et al. (2006) Nat Neurosci 9:1177-1185] and neurophysiology in face patches in the monkey brain [Tsao DY, et al. (2006) Science 311:670-674] reveal no reliable selectivity for objects. It is thus possible that FFA responses to objects with SR-fMRI are a result of spatial blurring of responses from nonface-selective areas, potentially driven by attention to objects of expertise. Using HR-fMRI in two experiments, we provide evidence of reliable responses to cars in the FFA that correlate with behavioral car expertise. Effects of expertise in the FFA for nonface objects cannot be attributed to spatial blurring beyond the scale at which modular claims have been made, and within the lateral fusiform gyrus, they are restricted to a small area (200 mm(2) on the right and 50 mm(2) on the left) centered on the peak of face selectivity. Experience with a category may be sufficient to explain the spatially clustered face selectivity observed in this region.

  10. Reliable Coverage Area Based Link Expiration Time (LET) Routing Metric for Mobile Ad Hoc Networks

    Science.gov (United States)

    Ahmed, Izhar; Tepe, K. E.; Singh, B. K.

    This paper presents a new routing metric for mobile ad hoc networks. It considers both coverage area as well as link expiration information, which in turn requires position, speed and direction information of nodes in the network. With this new metric, a routing protocol obtains routes that last longer with as few hops as possible. The proposed routing metric is implemented with Ad Hoc On-Demand Distance Vector Routing (AODV) protocol. Thus, the performance of the proposed routing metric is tested against the minimum hop metric of AODV. Simulation results show that the AODV protocol with the new routing metric significantly improves delivery ratio and reduces routing overhead. The delay performance of AODV with the new metric is comparable to its minimum hop metric implementation.

  11. Comparing the electrical characteristics and reliabilities of BJTs and MOSFETs between Pt and Ti contact silicide processes

    Science.gov (United States)

    Liu, Kaiping; Shang, Ling

    1999-08-01

    The sub-threshold characteristics and the reliability of BJTs, using platinum contact silicide (PtSi) or titanium contact silicide (TiSi2), are compared and analyzed. During processing, it is observed that the TiSi2 process produces higher interface state density (Dit) than the PtSi process. The increase in Dit not only leads to a higher base current in the BJTs, but also leads to a lower transconductance for the MOS transistors. The data also show that the impact on NPN and nMOS is more severe than the impact of PNP and pMOS, respectively. This can be explained by the non-symmetric interface state distribution, the re- activation of boron, and/or by substrate trap centers. The amount of interface states produced depends not only on the thickness of the titanium film deposited, but also on the temperature and duration of the titanium silicide process. The electrical data indicates that after all the Back-End- Of-The-Line processing steps, which includes a forming gas anneal, Dit is still higher on wafers with the TiSi2 transistor's base current increases at different rates between the two processes, but eventually levels off to the same final value. However, the PNP transistor's base current increases at approximately the same rate, but eventually levels off at different final values. These indicate that the TiSi2 process may have modified the silicon and oxygen dangling bond structure during its high temperature process in addition to removing the hydrogen from the passivated interface states.

  12. Reliable nanomaterial classification of powders using the volume-specific surface area method

    Science.gov (United States)

    Wohlleben, Wendel; Mielke, Johannes; Bianchin, Alvise; Ghanem, Antoine; Freiberger, Harald; Rauscher, Hubert; Gemeinert, Marion; Hodoroaba, Vasile-Dan

    2017-02-01

    The volume-specific surface area (VSSA) of a particulate material is one of two apparently very different metrics recommended by the European Commission for a definition of "nanomaterial" for regulatory purposes: specifically, the VSSA metric may classify nanomaterials and non-nanomaterials differently than the median size in number metrics, depending on the chemical composition, size, polydispersity, shape, porosity, and aggregation of the particles in the powder. Here we evaluate the extent of agreement between classification by electron microscopy (EM) and classification by VSSA on a large set of diverse particulate substances that represent all the anticipated challenges except mixtures of different substances. EM and VSSA are determined in multiple labs to assess also the level of reproducibility. Based on the results obtained on highly characterized benchmark materials from the NanoDefine EU FP7 project, we derive a tiered screening strategy for the purpose of implementing the definition of nanomaterials. We finally apply the screening strategy to further industrial materials, which were classified correctly and left only borderline cases for EM. On platelet-shaped nanomaterials, VSSA is essential to prevent false-negative classification by EM. On porous materials, approaches involving extended adsorption isotherms prevent false positive classification by VSSA. We find no false negatives by VSSA, neither in Tier 1 nor in Tier 2, despite real-world industrial polydispersity and diverse composition, shape, and coatings. The VSSA screening strategy is recommended for inclusion in a technical guidance for the implementation of the definition.

  13. Effects of coil orientation on the electric field induced by TMS over the hand motor area.

    Science.gov (United States)

    Laakso, Ilkka; Hirata, Akimasa; Ugawa, Yoshikazu

    2014-01-01

    Responses elicited by transcranial magnetic stimulation (TMS) over the hand motor area depend on the position and orientation of the stimulating coil. In this work, we computationally investigate the induced electric field for multiple coil orientations and locations in order to determine which parts of the brain are affected and how the sensitivity of motor cortical activation depends on the direction of the electric field. The finite element method is used for calculating the electric field induced by TMS in two individual anatomical models of the head and brain. The orientation of the coil affects both the strength and depth of penetration of the electric field, and the field strongly depends on the direction of the sulcus, where the target neurons are located. The coil position that gives the strongest electric field in the target cortical region may deviate from the closest scalp location by a distance on the order of 1 cm. Together with previous experimental data, the results support the hypothesis that the cortex is most sensitive to fields oriented perpendicular to the cortical layers, while it is relatively insensitive to fields parallel to them. This has important implications for targeting of TMS. To determine the most effective coil position and orientation, it is essential to consider both biological (the direction of the targeted axons) and physical factors (the strength and direction of the electric field).

  14. Seeing scenes: topographic visual hallucinations evoked by direct electrical stimulation of the parahippocampal place area.

    Science.gov (United States)

    Mégevand, Pierre; Groppe, David M; Goldfinger, Matthew S; Hwang, Sean T; Kingsley, Peter B; Davidesco, Ido; Mehta, Ashesh D

    2014-04-16

    In recent years, functional neuroimaging has disclosed a network of cortical areas in the basal temporal lobe that selectively respond to visual scenes, including the parahippocampal place area (PPA). Beyond the observation that lesions involving the PPA cause topographic disorientation, there is little causal evidence linking neural activity in that area to the perception of places. Here, we combined functional magnetic resonance imaging (fMRI) and intracranial EEG (iEEG) recordings to delineate place-selective cortex in a patient implanted with stereo-EEG electrodes for presurgical evaluation of drug-resistant epilepsy. Bipolar direct electrical stimulation of a cortical area in the collateral sulcus and medial fusiform gyrus, which was place-selective according to both fMRI and iEEG, induced a topographic visual hallucination: the patient described seeing indoor and outdoor scenes that included views of the neighborhood he lives in. By contrast, stimulating the more lateral aspect of the basal temporal lobe caused distortion of the patient's perception of faces, as recently reported (Parvizi et al., 2012). Our results support the causal role of the PPA in the perception of visual scenes, demonstrate that electrical stimulation of higher order visual areas can induce complex hallucinations, and also reaffirm direct electrical brain stimulation as a tool to assess the function of the human cerebral cortex.

  15. Effect of Heat and Electricity Storage and Reliability on Microgrid Viability:A Study of Commercial Buildings in California and New York States

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Siddiqui, Afzal; Lai, Judy; Coffey, Brian; Aki, Hirohisa

    2008-12-01

    In past work, Berkeley Lab has developed the Distributed Energy Resources Customer Adoption Model (DER-CAM). Given end-use energy details for a facility, a description of its economic environment and a menu of available equipment, DER-CAM finds the optimal investment portfolio and its operating schedule which together minimize the cost of meeting site service, e.g., cooling, heating, requirements. Past studies have considered combined heat and power (CHP) technologies. Methods and software have been developed to solve this problem, finding optimal solutions which take simultaneity into account. This project aims to extend on those prior capabilities in two key dimensions. In this research storage technologies have been added as well as power quality and reliability (PQR) features that provide the ability to value the additional indirect reliability benefit derived from Consortium for Electricity Reliability Technology Solutions (CERTS) Microgrid capability. This project is intended to determine how attractive on-site generation becomes to a medium-sized commercial site if economical storage (both electrical and thermal), CHP opportunities, and PQR benefits are provided in addition to avoiding electricity purchases. On-site electrical storage, generators, and the ability to seamlessly connect and disconnect from utility service would provide the facility with ride-through capability for minor grid disturbances. Three building types in both California and New York are assumed to have a share of their sensitive electrical load separable. Providing enhanced service to this load fraction has an unknown value to the facility, which is estimated analytically. In summary, this project began with 3 major goals: (1) to conduct detailed analysis to find the optimal equipment combination for microgrids at a few promising commercial building hosts in the two favorable markets of California and New York; (2) to extend the analysis capability of DER-CAM to include both heat and

  16. Damage costs produced by electric power plants: an externality valuation in the Mexico City Metropolitan Area.

    Science.gov (United States)

    Macías, P; Islas, J

    2010-09-15

    This paper presents an estimate of the externalities produced in the Mexico City Metropolitan Area (MCMA) through the impacts on health caused by secondary pollutants attributed to seven electric power plants located outside this area. An original method was developed to make possible a simplified application of the impact pathway approach to estimate the damage costs in the specified area. Our estimate shows that the annual costs attributed to secondary pollutants total 71 million USD (min/max 20/258 million USD). Finally, this paper discusses basic ideas on the implications for energy policy arising from this exercise in externality valuation.

  17. Load area aggregation considering integration of electric vehicles to the system

    Directory of Open Access Journals (Sweden)

    L. F. Rodríguez Garcia

    2015-11-01

    Full Text Available Current electric power systems have an increasing penetration of electric vehicles, and its effect has to be considered in different studies, such as optimal dispatch or voltage stability, among others. Additionally, considering that power system analysis becomes complex when the number of buses increase, this paper presents a methodology for aggregation of load areas that use a measurement-based load modeling approach based on an evolutionary computational technique and a classical reduction method. This aggregate load area model is proposed to reduce areas that ddconsider electric vehicle (EV load models. The proposed method provides a static equivalent load model and an equivalent network that can be used to reduce the computational effort required by power system studies. In order to validate the application of the proposed methodology, a 30-bus power system considering several disturbances and levels of penetration of the electric vehicles was used. The results show that the equivalent network model allows the reproduction of different events with an acceptable accuracy when it is compared to the original system behavior.

  18. Technical and legal considerations and solutions in the area of battery charging for electric vehicles

    Science.gov (United States)

    Juda, Z.

    2016-09-01

    The issue of protecting health of residents of urbanized areas from the effect of excessive particulate matter and toxic components of car exhaust gases imposes the need of introduction of clean electric vehicles to the market. The increasing market availability of electric vehicles, especially in the segment of short-range (neighborhood) vehicles is followed by development of new and advanced infrastructure solutions. This also applies to the increasingly popular hybrid vehicles PHEV (Plug-in Hybrid Electric Vehicles). However, problems with the existing designs are primarily associated with limited driving range on a single battery charge, the density of charging stations in urban and suburban area, energy system efficiency due to increased electricity demand and the unification of solutions for charging stations, on-board chargers and the necessary accessories. Technical solutions are dependent on many factors, including the type and size of battery in the vehicle and access to power grid with increased load capacity. The article discusses the legal and technical actions outlined in the above directions. It shows the available and planned solutions in this area.

  19. Evaluation of electrical tomography to estimate soil water storage capacity in forested Karstic areas

    Science.gov (United States)

    Xie, Yingge; Chanzy, André

    2010-05-01

    Given that the large physical heterogeneous in forested karstic areas, water storage capacity estimation is always a difficulty. This study aims to evaluate the electrical resistivity tomography for the water storage capacity estimation in forested karstic areas. The electric tomography was implemented to estimate the stone volumic content and the bedrock depth determination. These caracteristics are combined to the water storage capacity of the fine earth made by the pressure chamber method. To estimate stone content we assumed that soil is a biphasic media with stones embedded in the fine earth media. We computed the effective resistivity with the Bussian (1983) law, which was evaluated against numerical results. It has been shown that the major factors were the electric resistivity of each phase, whereas the size of the stone had a lower impact. Based on independent measurements, we found an accuracy of about 20%. The bedrock apparition can be detected by establishing a threshold. This threshold is much lower than the resitivity made on rock sample due to cracks filled by conductive media. An estimation of the water storage capacity was then made by combining fine earth hydraulic characteristics, estimation of stone content and bedrock depth. An error assessment has shown that the spatial variability is larger than the estimation error. Bussian, A.E., 1983. Electrical conductance in a Porous-medium, Geophysics, 48(9): 1258-1268.

  20. Control of combustion area using electrical resistivity method for underground coal gasification

    Institute of Scientific and Technical Information of China (English)

    Selivanova Tatiana; Grebenyuk Igor; Belov Alexey

    2012-01-01

    Underground coal gasification (UCG) is one of the clean technologies to collect heat energy and gases (hydrogen,methane,etc.) in an underground coal seam.It is necessary to further developing environmentally friendly UCG system construction.One of the most important UCG's problems is underground control of combustion area for efficient gas production,estimation of subsidence and gas leakage to the surface.For this objective,laboratory experiments were conducted according to the UCG model to identify the process of combustion cavity development by monitoring the electrical resistivity activity on the coal samples to setup fundamental data for the technology engineering to evaluate combustion area.While burning coal specimens,that had been sampled from various coal deposits,electrical resistivity was monitored.Symmetric four electrodes system (ABMN) of direct and low-frequency current electric resistance method was used.for laboratory resistivity measurement of rock samples.Made research and the results suggest that front-end of electro conductivity activity during heating and combusting of coal specimen depended on heating temperature.Combusting coal electro conductivity has complicated multistage type of change.Electrical resistivity method is expected to be a useful geophysical tool to for evaluation of combustion volume and its migration in the coal seam.

  1. A case study review of technical and technology issues for transition of a utility load management program to provide system reliability resources in restructured electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Weller, G.H.

    2001-07-15

    Utility load management programs--including direct load control and interruptible load programs--were employed by utilities in the past as system reliability resources. With electricity industry restructuring, the context for these programs has changed; the market that was once controlled by vertically integrated utilities has become competitive, raising the question: can existing load management programs be modified so that they can effectively participate in competitive energy markets? In the short run, modified and/or improved operation of load management programs may be the most effective form of demand-side response available to the electricity system today. However, in light of recent technological advances in metering, communication, and load control, utility load management programs must be carefully reviewed in order to determine appropriate investments to support this transition. This report investigates the feasibility of and options for modifying an existing utility load management system so that it might provide reliability services (i.e. ancillary services) in the competitive markets that have resulted from electricity industry restructuring. The report is a case study of Southern California Edison's (SCE) load management programs. SCE was chosen because it operates one of the largest load management programs in the country and it operates them within a competitive wholesale electricity market. The report describes a wide range of existing and soon-to-be-available communication, control, and metering technologies that could be used to facilitate the evolution of SCE's load management programs and systems to provision of reliability services. The fundamental finding of this report is that, with modifications, SCE's load management infrastructure could be transitioned to provide critical ancillary services in competitive electricity markets, employing currently or soon-to-be available load control technologies.

  2. Electric Service Areas, Electric Survey Providers in Turner County, GA, Published in 2006, 1:2400 (1in=200ft) scale, Southern Georgia Regional Commission.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Service Areas dataset, published at 1:2400 (1in=200ft) scale, was produced all or in part from Hardcopy Maps information as of 2006. It is described as...

  3. Electric Service Areas, Electric Survey Providers in Tift County, GA, Published in 2006, 1:2400 (1in=200ft) scale, Southern Georgia Regional Commission.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Service Areas dataset, published at 1:2400 (1in=200ft) scale, was produced all or in part from Hardcopy Maps information as of 2006. It is described as...

  4. Population response propagation to extrastriate areas evoked by intracortical electrical stimulation in V1

    Directory of Open Access Journals (Sweden)

    Tamas David Fehervari

    2016-02-01

    Full Text Available The mouse visual system has multiple extrastriate areas surrounding V1 each with a distinct representation of the visual field and unique functional and connectivity profiles, which are believed to form two parallel processing streams, similar to the ventral and dorsal streams in primates. At the same time, mouse visual areas have a high degree of interconnectivity, in particular V1 sends input to all higher visual areas. The study of these direct connections can further our understanding of the cortical processing of visual signals in the early mammalian cortex. Several studies have been published about the anatomy of these connections, but an in vivo electrophysiological characterization and comparison of the transmission to multiple extrastriate areas has not yet been reported. We used intracortical electrical stimulation combined with RH1691 VSD imaging in adult C57BL/6 mice in urethane anesthesia to analyze interareal transmission from V1 to extrastriate areas in superficial cortical layers. We found 7 extrastriate response sites (5 lateral, 2 medial in a spatial pattern similar to area maps of the mouse visual cortex and, by shifting the location of V1 stimulation, demonstrated that the evoked responses in LM and AL were in accordance with the visuotopic mappings of these areas known from anatomy and in vivo studies. These two sites, considered to be gateways to their processing streams, had shorter latencies and faster transmission speeds than other extrastriate response sites. Short latency differences between response sites, and that TTX injection into LM reduced but did not eliminate other extrastriate responses indicated that the evoked cortical activity was, at least partially, transmitted directly from V1 to extrastriate areas. This study reports on analysis of interareal transmission from V1 to multiple extrastriate areas in mouse using intracortical electrical stimulation in vivo.

  5. Long term forecasting of hourly electricity consumption in local areas in Denmark

    DEFF Research Database (Denmark)

    Møller Andersen, Frits; Larsen, Helge V.; Gaardestrup, R.B.

    2013-01-01

    to change proportional to changes in the aggregated national electricity consumption. That is, specific local conditions are not considered. Yet, from measurements of local consumption we know that:. •consumption profiles differ between local areas,•consumption by categories of customers contribute...... differently to the aggregated consumption profile,•the weight of categories of customers differ between local areas.In this paper we present a model calculating local consumption as composed of consumption by categories of customers with specific consumption profiles and different weights in local areas...... of annual consumption by categories of customers, the model is used to project hourly consumption profiles for selected local areas and results are compared to projections using the existing methodology. © 2013 Elsevier Ltd....

  6. Voltage control and protection in electrical power systems from system components to wide-area control

    CERN Document Server

    Corsi, Sandro

    2015-01-01

    Based on the author’s twenty years of experience, this book shows the practicality of modern, conceptually new, wide area voltage control in transmission and distribution smart grids, in detail. Evidence is given of the great advantages of this approach, as well as what can be gained by new control functionalities which modern technologies now available can provide. The distinction between solutions of wide area voltage regulation (V-WAR) and wide area voltage protection (V-WAP) are presented, demonstrating the proper synergy between them when they operate on the same power system as well as the simplicity and effectiveness of the protection solution in this case. The author provides an overview and detailed descriptions of voltage controls, distinguishing between generalities of underdeveloped, on-field operating applications and modern and available automatic control solutions, which are as yet not sufficiently known or perceived for what they are: practical, high-performance and reliable solutions. At th...

  7. Area of Interest 4.Technical Interest to Electric Infrastructure Planners on Other Subjects

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-07-01

    In 2010, the U.S. Department of Energy (DOE) provided $60M in funding to five regional entities to conduct interregional transmission planning activities: the Eastern Interconnection Planning Collaborative (EIPC); the Eastern Interconnection States Planning Council (EISPC); the Transmission Expansion Planning and Policy Committee (TEPPC); the State Provincial Steering Committee (SPSC);and the Electricity Reliability Council of Texas (ERCOT). DOE also provided funding to the Lawrence Berkeley National Laboratory (LBNL) to support aspects of these interregional transmission planning activities. LBNL’s support involved both technical assistance to DOE in its oversight of the activities conducted by the five regional entities and the preparation of six, standalone technical studies that were conducted in direct support for specific entities. This is the final report on LBNL’s activities. It consists of summaries of each activity; references are provided to each of the stand-alone studies.

  8. Test-Retest Reliability of 10 Hz Conditioning Electrical Stimulation Inducing Long-Term Potentiation (LTP)-Like Pain Amplification in Humans

    Science.gov (United States)

    Xia, Weiwei; Mørch, Carsten Dahl; Andersen, Ole Kæseler

    2016-01-01

    Background 10 Hz conditioning electrical stimulation (CES) has been shown to induce long-term potentiation (LTP)-like pain amplification similar to traditional 100 Hz CES in healthy humans. The aim of this study was to assess the test-retest reliability and to estimate sample sizes required for future crossover and parallel study designs. Methods The 10 Hz paradigm (500 rectangular pulses lasting 50 s) was repeated on two separate days with one week interval in twenty volunteers. Perceptual intensities to single electrical stimulation (SES) at the conditioned skin site and to mechanical stimuli (pinprick and light stroking) in immediate vicinity to the conditioned skin site were recorded. Superficial blood flow (SBF) was assessed as indicator of neurogenic inflammation. All outcome measures were assessed with 10 min interval three times before and six times after the CES. The coefficient of variation and intra-class correlation coefficient were calculated within session and between sessions. Sample sizes were estimated for future crossover (Ncr) and parallel (Np) drug testing studies expected to detect a 30% decrease for the individual outcome measure following 10 Hz CES. Results Perceptual intensity ratings to light stroking (Ncr = 2, Np = 33) and pinprick stimulation (491 mN) (Ncr = 6, Np = 54) increased after CES and showed better reliability in crossover than parallel design. The SBF increased after CES, and then declined until reaching a plateau 20 minutes postCES. SBF showed acceptable reliability both in crossover and parallel designs (Ncr = 3, Np = 13). Pain ratings to SES were reliable, but with large estimated sample sizes (Ncr = 634, Np = 11310) due to the minor pain amplification. Conclusions The reliability of 10 Hz CES was acceptable in inducing LTP-like effects in the assessments of superficial blood flow, heterotopic mechanical hyperalgesia, and dysesthesia in terms of sample sizes for future crossover study designs. PMID:27529175

  9. Reliability optimization in compound electric power systems with the aid of evolutionary algorithms; Optimizacion de la confiabilidad en sistemas electricos de potencia compuestos utilizando algoritmos evolucionarios

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Hernandez, Jose Alberto

    2001-11-15

    The purpose of evaluating the reliability of Electric Power Systems is to estimate the ability of the system to carry out their function of taking the energy from the generating stations to the load points. This involves the reliability of generation sources and transmission that affect in the transfer of power through the transmission system that bears load loss and voltage sags between the generation and the consumption centers. In this thesis a hybrid methodology that optimize the reliability in systems generation -transmission using evolutionary algorithms is developed. This technique of optimization determines the optimum number of components (parallel redundancy in lines) and shunt compensation in load nodes necessary to maximize reliability, subject to cost restrictions, and considering security conditions in steady state, using the smallest singular value technique. The objective function will be defined as stochastic function, where the measure of interests is the smallest singular value of the Jacobian matrix of power flows solution of the most severe event according to the evaluation of reliability of the generation transmission system, this formulation is a combination of integer and continuous non linear programming, where the conventional mathematical programming algorithms present difficulties in robustness and global optimal search. The fault in generation units is determined by using the state sampling together with the transmission system by Monte Carlo simulation for a desired load level. For events where violations in security exist (lines loading, violation in voltage in load nodes and violation in reactive power of generation nodes) a model of active and reactive power dispatch is used in order to correct these violations by means of the exact penalty function linear programming technique to proceeded to determine the stability of voltage in steady state by means of the smallest singular value technique and the participation factors of nodes

  10. Electrical heating of well bore area in wells of Uzbekistan oil region

    Energy Technology Data Exchange (ETDEWEB)

    Alidzhanov, G.A.; Osmanov, M.T.; Simkin, E.M.; Sheinman, A.B.

    1966-11-01

    The productivity of many wells in the Fergan area, Uzbekistan, decreased to 1/6 of initial value in the first year of production. Stimulation with hot gasoline or acid was only moderately successful. Best results were obtained by installing an electrical heater opposite the pay zone. In a typical case, well No. 464 (562 m deep) was completed in 1962 with an initial production of 10 tons/day. After 4 acid treatments, production was 2.5 tons/day in 1964, bottomhole temperature was 33$C, and pressure was 20 kg/cmU2D. A 10.5-kw electric heater was used for 3 days to raise bottomhole temperature to 52$C. Production increased to 3.5 tons/day and remained at that level for a month. In a second treatment a 21-kw heater increased bottomhole temperature to 120$C, whereupon production increased to 4.3 tons/day, and remained at that level for 3.5 months. Similar results were obtained in many other wells. Electrical method of stimulation is more economical than other methods in this area.

  11. High-Surface-Area Nitrogen-Doped Reduced Graphene Oxide for Electric Double-Layer Capacitors.

    Science.gov (United States)

    Youn, Hee-Chang; Bak, Seong-Min; Kim, Myeong-Seong; Jaye, Cherno; Fischer, Daniel A; Lee, Chang-Wook; Yang, Xiao-Qing; Roh, Kwang Chul; Kim, Kwang-Bum

    2015-06-08

    A two-step method consisting of solid-state microwave irradiation and heat treatment under NH3 gas was used to prepare nitrogen-doped reduced graphene oxide (N-RGO) with a high specific surface area (1007 m(2)  g(-1) ), high electrical conductivity (1532 S m(-1) ), and low oxygen content (1.5 wt %) for electrical double-layer capacitor applications. The specific capacitance of N-RGO was 291 F g(-1) at a current density of 1 A g(-1) , and a capacitance of 261 F g(-1) was retained at 50 A g(-1) , which indicated a very good rate capability. N-RGO also showed excellent cycling stability and preserved 96 % of the initial specific capacitance after 100 000 cycles. Near-edge X-ray absorption fine-structure spectroscopy results provided evidenced for the recovery of π conjugation in the carbon networks with the removal of oxygenated groups and revealed chemical bonding of the nitrogen atoms in N-RGO. The good electrochemical performance of N-RGO is attributed to its high surface area, high electrical conductivity, and low oxygen content.

  12. The Electricity Feed Law levy - how reliably can it be predicted?; Wie verlaesslich laesst sich die EEG-Umlage prognostizieren?

    Energy Technology Data Exchange (ETDEWEB)

    Bause, Rainer; Schulz, Woldemar [Amprion GmbH, Dortmund (Germany); Buehler, Holger [EnBW TNG, Stuttgart (Germany); Hodurek, Claus [50Hertz Transmission GmbH, Berlin (Germany); Kiessling, Axel [TenneT TSO GmbH, Bayreuth (Germany)

    2011-10-15

    By paying their monthly electricity bill German consumers are promoting the transition to tomorrow's resource-efficient electricity supply system, in which the largest part of electricity used is to come from renewable energy resources. Every year Germany's transmission system operators publish what is referred to as the ''EEG-Umlage'' (report on the Electricity Feed Law levy, or EEG levy), which shows how much every German household will be paying for the promotion of renewable energies in the coming year. The determination of the EEG levy involves uncertainties and imponderabilities which have to be taken into account in its calculation. The crucial task is to find a suitable systematic scheme for predicting the renewable energy yield.

  13. To Problem of Electric Supply Reliability for Consumers of Agro-Industrial Complex with Development of Market Relations in Electric Power Industry

    Directory of Open Access Journals (Sweden)

    G. F. Kutsenko

    2006-01-01

    Full Text Available The paper considers a number of problems concerning relations between power-supply organizations and agro-industrial complex enterprises in respect of reliability of power supply to electro-receivers. Some concrete measures that are supposed to improve these relations under modem conditions are offered in the paper/

  14. Reliability of calculation of the lithosphere deformations in tectonically stable area of Poland based on the GPS measurements

    Science.gov (United States)

    Araszkiewicz, Andrzej; Jarosiński, Marek

    2013-04-01

    In this research we aimed to check if the GPS observations can be used for calculation of a reliable deformation pattern of the intracontinental lithosphere in seismically inactive areas, such as territory of Poland. For this purpose we have used data mainly from the ASG-EUPOS permanent network and the solutions developed by the MUT CAG team (Military University of Technology: Centre of Applied Geomatics). From the 128 analyzed stations almost 100 are mounted on buildings. Daily observations were processed in the Bernese 5.0 software and next the weekly solutions were used to determine the station velocities expressed in ETRF2000. The strain rates were determined for almost 200 triangles with GPS stations in their corners plotted used Delaunay triangulation. The obtained scattered directions of deformations and highly changeable values of strain rates point to insufficient antennas' stabilization as for geodynamical studies. In order to depict badly stabilized stations we carried out a benchmark test to show what might be the effect of one station drift on deformations in contacting triangles. Based on the benchmark results, from our network we have eliminated the stations which showed deformation pattern characteristic for instable station. After several rounds of strain rate calculations and eliminations of dubious points we have reduced the number of stations down to 60. The refined network revealed more consistent deformation pattern across Poland. Deformations compared with the recent stress field of the study area disclosed good correlation in some places and significant discrepancies in the others, which will be the subject of future research.

  15. Reliability of offshore wind power production under extreme wind conditions. Deliverable D 9.5. Work Package 9: Electrical grid

    DEFF Research Database (Denmark)

    Cutululis, Nicolaos Antonio; Zeni, Lorenzo

    Reliability of offshore wind production under extreme wind conditions was investigated in this report. The wind power variability from existing and future large offshore wind farms in Western Denmark were simulated using the Correlated Wind model developed at Risø. The analysis was done for five ...... ramp rates and reserves requirements....

  16. Advanced Control of Wind Electric Pumping System for Isolated Areas Application

    Directory of Open Access Journals (Sweden)

    Mohamed Barara

    2014-12-01

    Full Text Available The supply water in remote areas of windy region is one of most attractive application of wind energy conversion .This paper proposes an advanced controller suitable for wind-electric pump in isolated applications in order to have a desired debit from variation of reference speed of the pump also the control scheme of DC voltage of SIEG for feed the pump are presented under step change in wind speed. The simulation results showed a good performance of the global proposed control system.

  17. Health and safety impacts of nuclear, geothermal, and fossil-fuel electric generation in California. Volume 7. Power plant reliability-availability and state regulation

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Bouromand, I.N.M.N.

    1977-01-01

    Data from the Edison Electric Institute annual report on equipment availability are briefly examined with a view to determining the breadth of effort which would be required to reduce outage time caused by equipment difficulties. For nuclear units, for several size categories of fossil units, and for gas turbine units, the basic data are examined to establish the basic operating experience and related outage and availability rates, and to assign outages to major plant systems. Related data giving detailed outage causes are grouped to yield data on component failure versus outage time, information that is required to determine the possible impact of research and regulatory efforts on reliability and availability.

  18. IMPROVING THE RELIABILITY OF THE POWER CIRCUIT OF THE ELECTRIC TRAINS ЕР2Т AND ЕПЛ2Т

    Directory of Open Access Journals (Sweden)

    N. H. Visin

    2010-02-01

    Full Text Available The transitional processes in shunt circuit of traction engines, which armatures and excitation windings are connected in non-conducting direction as to the flowing power current, are considered in this paper. The changes in the control circuits of braking switch and in the shunt power circuit of traction engines with additional mounting a resistor of 0.5 Ohm are proposed. All this modernization will allow increasing greatly the operation reliability of power circuit of ЭР2Т and ЕПЛ2Т electric locomotives during their service life.

  19. System for the reliability analysis of the electric energy supply; Sistema para el analisis de confiabilidad del suministro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Perales, Favio; Martinez, Javier; Huesca, Francisco; Garcia, Norma; Nieva, Rolando [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    A computer tool, developed for the reliability evaluation of the electric energy supply, considering the faults in the generation and transmission systems, is presented. The application of the tool in planning the expansion and operation of the electric systems, the methodology of the solution employed and the various functions it accounts for, are described. At the end some illustrative examples of its applications by means of the studies with a model of representative characteristics of the interconnected national system. [Espanol] Se presenta una herramienta computacional desarrollada para evaluar la confiabilidad del suministro de energia electrica, considerando las fallas en los sistemas de generacion y transmision. Se describen las aplicaciones de la herramienta en la planeacion de la expansion y de la operacion de sistemas electricos, la metodologia de solucion empleada y las diversas funciones con que cuenta. Al final se presentan algunos ejemplos ilustrativos de sus aplicaciones mediante estudios con un modelo de caracteristicas representativas del sistema interconectado nacional.

  20. Four-point probe electrical resistivity scanning system for large area conductivity and activation energy mapping.

    Science.gov (United States)

    Shimanovich, Klimentiy; Bouhadana, Yaniv; Keller, David A; Rühle, Sven; Anderson, Assaf Y; Zaban, Arie

    2014-05-01

    The electrical properties of metal oxides play a crucial role in the development of new photovoltaic (PV) systems. Here we demonstrate a general approach for the determination and analysis of these properties in thin films of new metal oxide based PV materials. A high throughput electrical scanning system, which facilitates temperature dependent measurements at different atmospheres for highly resistive samples, was designed and constructed. The instrument is capable of determining conductivity and activation energy values for relatively large sample areas, of about 72 × 72 mm(2), with the implementation of geometrical correction factors. The efficiency of our scanning system was tested using two different samples of CuO and commercially available Fluorine doped tin oxide coated glass substrates. Our high throughput tool was able to identify the electrical properties of both resistive metal oxide thin film samples with high precision and accuracy. The scanning system enabled us to gain insight into transport mechanisms with novel compositions and to use those insights to make smart choices when choosing materials for our multilayer thin film all oxide photovoltaic cells.

  1. Approach to valuing visual pollution from Western Electricity Production. [For Western Systems Coordinating Council area

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, L.E.

    1977-02-01

    This paper outlines an approach to valuing visual pollution from electric power plants. The differences between public-good pollution externalities, such as these aesthetic damages, and other market failures are discussed. Approaches generally used to value externalities are briefly described. The approach used relies heavily on an earlier application of bidding games to estimate people's willingness to pay for abatement of emissions from the Four Corners fossil-fuel power plant in northwestern New Mexico. The results of these surveys were used here to estimate the value of visual pollution from electric power plants for residents of and visitors to the Four Corners Air Quality Control Region, as a function of power plant emissions in that region. The approach presented here for the Four Corners region is structured so that replication for other air quality control regions is relatively easy. Preliminary results of this procedure for all of the air quality control regions in the Western Systems Coordinating Council area are presented. Visual pollution damages from electric power plants to residents of and recreational visitors to these western regions are estimated to total more than $100 million annually by 1985. These damages are expected to occur unless additional pollution controls are implemented, even if these subject populations do not increase.

  2. Life Cycle Assessment of Motor Bike and Electric Bike in Urban Areas of China

    Institute of Scientific and Technical Information of China (English)

    DAI Du; LENG Ru-bo; ZHANG Cheng; WANG Cheng-tao

    2005-01-01

    Motor bikes (m-bike) and electric bikes (e-bike) are widely used in urban areas of China. Life cycle assessment of m-bike and e-bike are presented to compare their energy use and environmental emission in a life cycle span. An m-bike and an e-bike are disassembled to collect material composition data for the life cycle assessment. The results show that e-bike consumes less energy and has less global warming potential (GWP), biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), dissolved solids (DS), hydrocarbons (HC) than m-bike during life cycle. But e-bike generates more solid wastes, and more acidification potential (AP), heavy metal (HM) than m-bike. Advanced batteries and clean coal fired power plant technologies are recommended to promote e-bike use in urban area.

  3. Large-area WSe2 electric double layer transistors on a plastic substrate

    KAUST Repository

    Funahashi, Kazuma

    2015-04-27

    Due to the requirements for large-area, uniform films, currently transition metal dichalcogenides (TMDC) cannot be used in flexible transistor industrial applications. In this study, we first transferred chemically grown large-area WSe2 monolayer films from the as-grown sapphire substrates to the flexible plastic substrates. We also fabricated electric double layer transistors using the WSe2 films on the plastic substrates. These transistors exhibited ambipolar operation and an ON/OFF current ratio of ∼104, demonstrating chemically grown WSe2 transistors on plastic substrates for the first time. This achievement can be an important first step for the next-generation TMDC based flexible devices. © 2015 The Japan Society of Applied Physics.

  4. Electrical properties and reliability of HfO2 gate-dielectric MOS capacitors with trichloroethylene surface pretreatment

    Institute of Scientific and Technical Information of China (English)

    Xu Jing-Ping; Chen Wei-Bing; Lai Pui-To; Li Yan-Ping; Chan Chu-Lok

    2007-01-01

    Trichloroethylene (TCE) pretreatment of Si surface prior to HfO2 deposition is employed to fabricate HfO2 gatedielectric MOS capacitors. Influence of this processing procedure on interlayer growth, HfO2/Si interface properties,gate-oxide leakage and device reliability is investigated. Among the surface pretreatments in NH3, NO, N2O and TCE ambients, the TCE pretreatment gives the least interlayer growth, the lowest interface-state density, the smallest gate leakage and the highest reliability. All these improvements should be ascribed to the passivation effects of Cl2 and Hclon the structural defects in the interlayer and at the interface, and also their gettering effects on the ion contamination in the gate dielectric.

  5. Improved Reliability Models for Mechanical and Electrical Components at Navigation Lock and Dam and Flood Risk Management Facilities

    Science.gov (United States)

    2013-04-01

    Brake Electromechanical 45 60 Clutch Slip 30 — Jaw — 70 Wire ropes ERDC/CERL TR-13-4 104 Type Component Navigation Components CL (years...navigation facilities. Current USACE ME reliability methods use generic component failure rate data from US Department of Defense (DoD) Military Standard...MIL-STD) 756B, in which failure rate data is processed for components that function in operating environments, failure modes, and maintenance

  6. Improvement of quality and reliability of electric power supply using the supply transformer with under load tap change device

    Science.gov (United States)

    Grabko, Volodymyr V.; Balzan, Igor V.; Smolarz, Andrzej; Asambay, Azat

    2015-12-01

    On the base of the analysis of laws on voltage regulation by the supply transformers with the under load tap change device, the paper presents the modified regulation law, the use of which, unlike the known ones, allows to limit the number of tap changing of the supply transformer, which results in improvement of voltage quality of the consumers and the reliability of the under voltage tap change device operation.

  7. Electrical and optical characterization of an atmospheric pressure, uniform, large-area processing, dielectric barrier discharge

    Science.gov (United States)

    Zeniou, A.; Puač, N.; Škoro, N.; Selaković, N.; Dimitrakellis, P.; Gogolides, E.; Petrović, Z. Lj

    2017-04-01

    A printed-circuit-board (PCB) based atmospheric pressure dielectric barrier discharge (DBD) capable of uniform processing over a large area was constructed consisting of two parallel plates. The first perforated plate is comprised of four layers: a RF powered metal layer, a polymeric dielectric layer, a floating metal grid and another dielectric layer. The second, grounded, plate was fluorine doped tin oxide (FTO) glass plate with surface of 100  ×  100 mm2 and thickness of 2 mm. The PCB based atmospheric pressure DBD was characterized by (a) measuring electrical characteristics of the device using derivative I–V probes, (b) ICCD imaging and (c) optical emission spectroscopy (OES). Optical and electrical characteristics, as well as plasma uniformity were measured by changing He flow rate and input power, while keeping the gap between the PCB and the FTO glass plate ground electrode constant at 2 mm. The plasma uniformity strongly depends on the applied power and on the flow rate of the buffer gas. When increasing the flow rate, the intensity of the nitrogen-dominated emission drops, while emission of helium and oxygen lines increases. The source allows low temperature, uniform plasma operation over a wide area of 100  ×  100 mm2, which could be essential for numerous applications. Examples of etching rate and hydrophilization are demonstrated.

  8. Micro- and nanoscale electrical characterization of large-area graphene transferred to functional substrates

    Directory of Open Access Journals (Sweden)

    Gabriele Fisichella

    2013-04-01

    Full Text Available Chemical vapour deposition (CVD on catalytic metals is one of main approaches for high-quality graphene growth over large areas. However, a subsequent transfer step to an insulating substrate is required in order to use the graphene for electronic applications. This step can severely affect both the structural integrity and the electronic properties of the graphene membrane. In this paper, we investigated the morphological and electrical properties of CVD graphene transferred onto SiO2 and on a polymeric substrate (poly(ethylene-2,6-naphthalene dicarboxylate, briefly PEN, suitable for microelectronics and flexible electronics applications, respectively. The electrical properties (sheet resistance, mobility, carrier density of the transferred graphene as well as the specific contact resistance of metal contacts onto graphene were investigated by using properly designed test patterns. While a sheet resistance Rsh ≈ 1.7 kΩ/sq and a specific contact resistance ρc ≈ 15 kΩ·μm have been measured for graphene transferred onto SiO2, about 2.3× higher Rsh and about 8× higher ρc values were obtained for graphene on PEN. High-resolution current mapping by torsion resonant conductive atomic force microscopy (TRCAFM provided an insight into the nanoscale mechanisms responsible for the very high ρc in the case of graphene on PEN, showing a ca. 10× smaller “effective” area for current injection than in the case of graphene on SiO2.

  9. Interpretation of dipole-dipole electrical resistivity survey, Colado geothermal area, Pershing County, Nevada

    Science.gov (United States)

    Mackelprang, C. E.

    1980-09-01

    An electrical resistivity survey in the Colado geothermal area, Pershing County, Nevada has defined areas of low resistivity on each of five lines surveyed. Some of these areas appear to be fault controlled. Thermal fluids encountered in several drill holes support the assumption that the hot fluids may be associated with areas of low resistivity. The evidence of faulting as interpreted from modeling of the observed resistivity data is therefore particularly significant since these structures may be the conduits for the thermal fluids. Sub-alluvial fault zones are interpreted to occur between stations 0-5 NW on Line D and on Line A between stations 4 NW and 4 SE. Fault zones are also interpreted on Line C near stations 1 NW, 1 SE, and 3 SE, and on Line E between stations 2-4 NW and near 1 SE. No faulting is evident under the alluvial cover on the southwest end of Line B. A deep conductive zone is noted within the mountain range on two resistivity lines. There is no definite indication that thermal fluids are associated with this resistivity feature.

  10. AST Critical Propulsion and Noise Reduction Technologies for Future Commercial Subsonic Engines Area of Interest 1.0: Reliable and Affordable Control Systems

    Science.gov (United States)

    Myers, William; Winter, Steve

    2006-01-01

    The General Electric Reliable and Affordable Controls effort under the NASA Advanced Subsonic Technology (AST) Program has designed, fabricated, and tested advanced controls hardware and software to reduce emissions and improve engine safety and reliability. The original effort consisted of four elements: 1) a Hydraulic Multiplexer; 2) Active Combustor Control; 3) a Variable Displacement Vane Pump (VDVP); and 4) Intelligent Engine Control. The VDVP and Intelligent Engine Control elements were cancelled due to funding constraints and are reported here only to the state they progressed. The Hydraulic Multiplexing element developed and tested a prototype which improves reliability by combining the functionality of up to 16 solenoids and servo-valves into one component with a single electrically powered force motor. The Active Combustor Control element developed intelligent staging and control strategies for low emission combustors. This included development and tests of a Controlled Pressure Fuel Nozzle for fuel sequencing, a Fuel Multiplexer for individual fuel cup metering, and model-based control logic. Both the Hydraulic Multiplexer and Controlled Pressure Fuel Nozzle system were cleared for engine test. The Fuel Multiplexer was cleared for combustor rig test which must be followed by an engine test to achieve full maturation.

  11. Influence of Organ Pathology on the Electrical Parameters in Organ Projection Areas of the Skin

    Institute of Scientific and Technical Information of China (English)

    Jan Z.Szopinski; Georg P. Lochner; Desmond Pantanowitz

    2006-01-01

    Pathology of an internal organ causes significant rectification of electrical currents (diode phenomenon)in related skin areas - organ projection areas (OPAs), once the resistance 'breakthrough effect' has been induced in the skin. Also, the impedance of the diseased organ's projection areas is increased. The aim of this double-blind study was to confirm these phenomena statistically using a broad spectrum of measuring parameters. Skin impedance vs. Measurement frequency, skin impedance vs. Applied voltage,and skin resistance vs. Voltage were evaluated at 335 auricular OPAs related to the healthy internal organs and 203 auricular OPAs related to the diseased organs. These measurements confn-med that the skin electrical characteristics of specific locations are dependent on the health state of the corresponding internal organs. It was found that the impedance of OPAs corresponding to the healthy internal organs equals 185 ± 291 kΩ at 10Hz and decreases to 64 ± 49 kΩ at 10kHz; and that the impedance of OPAs related to the diseased organs equals 7.5 ± 2.2 MΩ at 10Hz and 99 ± 50kΩ at 10kHz. The disparity of the impedances between the healthy and diseased organs related OPAs is greater at higher potentials. The skin resistance, when measured with a negatively polarized point electrode, undergoes a rapid resistance decrease of approximately two orders of magnitude, if the applied current is sufficient. After this reversible 'breakthrough effect' is obtained the skin exhibits rectification. The degree of rectification is low for OPAs related to the healthy organs. For OPAs related to the diseased organs, the resistance measured with a positive polarisation of measuring electrode could be five times greater than the resistance measured at the same voltage with the same but negatively polarised electrode. The disparity between the resistance measured with a negatively and with a positively polarised electrode at OPAs related to the diseased organs was greater at

  12. PV Systems Reliability Final Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.

  13. Structural and electrical properties of large area epitaxial VO2 films grown by electron beam evaporation

    Science.gov (United States)

    Théry, V.; Boulle, A.; Crunteanu, A.; Orlianges, J. C.; Beaumont, A.; Mayet, R.; Mennai, A.; Cosset, F.; Bessaudou, A.; Fabert, M.

    2017-02-01

    Large area (up to 4 squared inches) epitaxial VO2 films, with a uniform thickness and exhibiting an abrupt metal-insulator transition with a resistivity ratio as high as 2.85 × 10 4 , have been grown on (001)-oriented sapphire substrates by electron beam evaporation. The lattice distortions (mosaicity) and the level of strain in the films have been assessed by X-ray diffraction. It is demonstrated that the films grow in a domain-matching mode where the distortions are confined close to the interface which allows growth of high-quality materials despite the high film-substrate lattice mismatch. It is further shown that a post-deposition high-temperature oxygen annealing step is crucial to ensure the correct film stoichiometry and provide the best structural and electrical properties. Alternatively, it is possible to obtain high quality films with a RF discharge during deposition, which hence do not require the additional annealing step. Such films exhibit similar electrical properties and only slightly degraded structural properties.

  14. Reliable fuzzy H∞ control for active suspension of in-wheel motor driven electric vehicles with dynamic damping

    Science.gov (United States)

    Shao, Xinxin; Naghdy, Fazel; Du, Haiping

    2017-03-01

    A fault-tolerant fuzzy H∞ control design approach for active suspension of in-wheel motor driven electric vehicles in the presence of sprung mass variation, actuator faults and control input constraints is proposed. The controller is designed based on the quarter-car active suspension model with a dynamic-damping-in-wheel-motor-driven-system, in which the suspended motor is operated as a dynamic absorber. The Takagi-Sugeno (T-S) fuzzy model is used to model this suspension with possible sprung mass variation. The parallel-distributed compensation (PDC) scheme is deployed to derive a fault-tolerant fuzzy controller for the T-S fuzzy suspension model. In order to reduce the motor wear caused by the dynamic force transmitted to the in-wheel motor, the dynamic force is taken as an additional controlled output besides the traditional optimization objectives such as sprung mass acceleration, suspension deflection and actuator saturation. The H∞ performance of the proposed controller is derived as linear matrix inequalities (LMIs) comprising three equality constraints which are solved efficiently by means of MATLAB LMI Toolbox. The proposed controller is applied to an electric vehicle suspension and its effectiveness is demonstrated through computer simulation.

  15. Vertical Electrical Sounding Investigation in East River Nile Area (Khartoum State),Sudan

    Institute of Scientific and Technical Information of China (English)

    Eldawi M G; Farwa A G; Liu Tianyou

    2003-01-01

    Vertical electrical sounding (VES) was carried out in the east of the River Nile. The main objectives of the resistivity survey are to determine the types and thicknesses of sedimentary units in the area, to defime the contact separating the sediments from the crystalline basement complex, and to determine the structural features of the subsurface formations. Several local depressions, whose maximum depth to the basement surface is about 160 m, are revealed as an outcome of the VES method, and suggested to have been infilled with undifferentiated units of the Nubian Group in particular Omdurman Formation. Thus, a depth to the basement complex is calculated and the associated structural map of the east of the River Nile is drawn. The map is useful for the groundwater drilling, as far as the presence or absence of the aquifer is concerned.

  16. Durability and Reliability of Electric Vehicle Batteries under Electric Utility Grid Operations. Part 1: Cell-to-Cell Variations and Preliminary Testing

    Directory of Open Access Journals (Sweden)

    Arnaud Devie

    2016-09-01

    Full Text Available Vehicle-to-grid (V2G and grid-to-vehicle (G2V strategies are considered to help stabilize the electric grid but their true impact on battery degradation is still unknown. The intention of this study is to test the impact of such strategies on the degradation of commercial Li-ion batteries. This first part looks into the preliminary testing performed prior to the start of degradation studies to ensure that the selected cells are compatible. Both the thermodynamic and kinetic cell-to-cell variation within the selected batch and the diagnostic-ability of the cells were investigated. The cells were found to have low cell-to-cell variations and are thus consistent. Moreover, the emulation of the full cell from the half-cell data prepared from harvested electrodes was successful and the degradation forecast showed that the main degradation modes can be differentiated.

  17. Upper Mantle Composition Beneath the Petit-Spot Area in Northwestern Pacific: Insights From Electrical Conductivity

    Science.gov (United States)

    Baba, K.; Ichiki, M.; Abe, N.; Hirano, N.

    2007-12-01

    The mantle composition beneath the petit-spot area, where is about 500 km offshore from Japan Trench in northwestern Pacific, is discussed through electrical conductivity obtained by seafloor magnetotelluric (MT) survey. The seafloor MT data were collected using ocean bottom electromagnetometers (OBEMs) at four sites with the spacing of 100-150 km, between May and August, 2005. The survey was conducted as a part of the petit-spot multidsciplinary project. The petit-spot is young volcanic activity on very old (~130 Ma) oceanic plate characterized as a clump of small knolls which erupted strong to moderate alkaline basalt. This volcanic field is associated with neither any plate boundaries nor hot spots. To elucidate the magma generation process of this new-type volcanic activity, a collaborative study of various geophysical and geochemical approaches has been carried out. The MT survey aims to constrain the physical state of the lithosphere and asthenosphere where the petit-spot melt is probably generated. The acquired electromagnetic field variation data were analyzed and the MT responses, which is the transfer function between the electric and magnetic fields, were obtained. The effect for the ocean-land distribution and seafloor topography on the MT responses was modeled and stripped. As the result, the corrected responses indicate that the lateral heterogeneity in electrical conductivity is less significant beneath the survey area. One- dimensional inversion study shows that the data require a peak in conductivity (0.05 S/m) at about 200 km depth. The mantle temperature may be calculated from the conductivity using an experimental result for dry olivine (Constable et al., 1992). The resultant temperature is about 1750 °C which is lower than the dry solidus for garnet peridotite. Instead, assuming the temperature as GDH1 model (Stein and Stein, 1992) for 130 Myr old mantle, we calculate water content in olivine using an experimental result by Wang et al. (2006

  18. Ship Electric Propulsion Simulation System Reliability Evaluation Based on Improved D-S Expert Weight Calculation Method

    Directory of Open Access Journals (Sweden)

    Bing Li

    2015-01-01

    Full Text Available In order to have a better evaluation process to determine the experts weight in the evaluation process, this paper proposes a new expert weight calculation method. First of all to establish electric propulsion simulation evaluation system, use AHP method to calculate the initial weight principle of index. Then use the D-S to fuse the experts evaluation information, combined with the weight vector, structure of the expert weight objective function, and through the genetic algorithm to solve the expert weight size. According to the expert weight vector, calculate the final weight vector. Not only can it greatly make use of the experts information and analyze the similarity of information effectively but also it calculates the weight of each expert objectively. At the same time the evaluation subjective factors have been reduced by the adoption of this new method.

  19. 78 FR 30804 - Transmission Planning Reliability Standards

    Science.gov (United States)

    2013-05-23

    ... proposed Reliability Standard TPL-001-2, submitted by the North American Electric Reliability Corporation... American Electric Reliability Corporation (NERC), the Commission-certified Electric Reliability... Microsoft Word format for viewing, printing, and/or downloading. To access this document in eLibrary,...

  20. Printed Circuit Board Surface Finish and Effects of Chloride Contamination, Electric Field, and Humidity on Corrosion Reliability

    Science.gov (United States)

    Conseil-Gudla, Hélène; Jellesen, Morten S.; Ambat, Rajan

    2017-02-01

    Corrosion reliability is a serious issue today for electronic devices, components, and printed circuit boards (PCBs) due to factors such as miniaturization, globalized manufacturing practices which can lead to process-related residues, and global usage effects such as bias voltage and unpredictable user environments. The investigation reported in this paper focuses on understanding the synergistic effect of such parameters, namely contamination, humidity, PCB surface finish, pitch distance, and potential bias on leakage current under different humidity levels, and electrochemical migration probability under condensing conditions. Leakage currents were measured on interdigitated comb test patterns with three different types of surface finish typically used in the electronics industry, namely gold, copper, and tin. Susceptibility to electrochemical migration was studied under droplet conditions. The level of base leakage current (BLC) was similar for the different surface finishes and NaCl contamination levels up to relative humidity (RH) of 65%. A significant increase in leakage current was found for comb patterns contaminated with NaCl above 70% to 75% RH, close to the deliquescent RH of NaCl. Droplet tests on Cu comb patterns with varying pitch size showed that the initial BLC before dendrite formation increased with increasing NaCl contamination level, whereas electrochemical migration and the frequency of dendrite formation increased with bias voltage. The effect of different surface finishes on leakage current under humid conditions was not very prominent.

  1. Printed Circuit Board Surface Finish and Effects of Chloride Contamination, Electric Field, and Humidity on Corrosion Reliability

    Science.gov (United States)

    Conseil-Gudla, Hélène; Jellesen, Morten S.; Ambat, Rajan

    2016-10-01

    Corrosion reliability is a serious issue today for electronic devices, components, and printed circuit boards (PCBs) due to factors such as miniaturization, globalized manufacturing practices which can lead to process-related residues, and global usage effects such as bias voltage and unpredictable user environments. The investigation reported in this paper focuses on understanding the synergistic effect of such parameters, namely contamination, humidity, PCB surface finish, pitch distance, and potential bias on leakage current under different humidity levels, and electrochemical migration probability under condensing conditions. Leakage currents were measured on interdigitated comb test patterns with three different types of surface finish typically used in the electronics industry, namely gold, copper, and tin. Susceptibility to electrochemical migration was studied under droplet conditions. The level of base leakage current (BLC) was similar for the different surface finishes and NaCl contamination levels up to relative humidity (RH) of 65%. A significant increase in leakage current was found for comb patterns contaminated with NaCl above 70% to 75% RH, close to the deliquescent RH of NaCl. Droplet tests on Cu comb patterns with varying pitch size showed that the initial BLC before dendrite formation increased with increasing NaCl contamination level, whereas electrochemical migration and the frequency of dendrite formation increased with bias voltage. The effect of different surface finishes on leakage current under humid conditions was not very prominent.

  2. Evaluation of oasis ecosystem risk by reliability theory in an arid area: A case study in the Shiyang River Basin,China

    Institute of Scientific and Technical Information of China (English)

    LI Wei-de; LI Zi-zhen; WANG Ji-quan

    2007-01-01

    Ecosystem risk is a new concept in understanding environmental problems. Studying and developing quantitative methods for regional ecosystem risk analysis is very important. In this study, some new indicators and methods for measuring oasis ecosystem risk are established using reliability theory. These indicators are linked to water resource, which is the key restricting factor in arid area oasis ecosystems. They have clear meanings and can also be compared in different arid area oases. A case study in the Liangzhou oasis of the Shiyang River Basin shows how to calculate these ecosystem risk indicators. The results of the case study are as follows: the reliability indicator, risk indicator, stability indicator, and integrated loss indicator of the Liangzhou oasis are 0.686, 0.334, 0.743, and 0.301, respectively. This means that the reliability degree of the oasis's ecosystem safety is 68.3%; the degree of risk that it is unsafe is 33.4%; the stability degree is 74.3%; and 30.1% of the oasis's area is supported by over-exploiting underground water and damaging the lower reaches of the ecosystem. This result can be used as a guide in controlling and managing ecosystem risk in the research area.

  3. Application Research on Drag Reduced Conductors for Electric Power Transmission Lines in Strong Wind Areas

    Directory of Open Access Journals (Sweden)

    Li Dong Qing

    2016-01-01

    Full Text Available The breeze vibration duration of conductors is long, the vibration amplitude is strong and the frequency range is wide for electric power transmission lines in strong wind areas, which seriously affects the safe and stable operation of transmission lines. There are two design schemes of conductors which can achieve the purpose of reducing wind-induced disaster. One is enhancing the structural strength of conductors to withstand wind load, but the investment is enormous and the effect is limited. The other is developing drag reduced conductors to reduce wind load by changing conductor structure. This paper started from application feasibility analysis of drag reduced conductors and designed four drag reduced conductors by structure optimization of the conventional aluminium conductor steel reinforced JL/G1A-630/45-45/7, denoted as DFY630/45(45°-R3.5, DFY630/45(60°-R3.5, DFY630/45(45°–R3.2 and DFY630/45(60°-R3.2, respectively. The wind tunnel test was performed and the wind resistance coefficients in unit length of five conductors were compared. Result showed that the wind resistance coefficients in unit length of four drag reduced conductors were obviously lower than that of the conventional conductor. By controlling the manufacturing process, popularization and application of drag reduced conductors for transmission lines in strong wind areas can be realized.

  4. Electrically tunable terahertz metamaterials with embedded large-area transparent thin-film transistor arrays.

    Science.gov (United States)

    Xu, Wei-Zong; Ren, Fang-Fang; Ye, Jiandong; Lu, Hai; Liang, Lanju; Huang, Xiaoming; Liu, Mingkai; Shadrivov, Ilya V; Powell, David A; Yu, Guang; Jin, Biaobing; Zhang, Rong; Zheng, Youdou; Tan, Hark Hoe; Jagadish, Chennupati

    2016-03-22

    Engineering metamaterials with tunable resonances are of great importance for improving the functionality and flexibility of terahertz (THz) systems. An ongoing challenge in THz science and technology is to create large-area active metamaterials as building blocks to enable efficient and precise control of THz signals. Here, an active metamaterial device based on enhancement-mode transparent amorphous oxide thin-film transistor arrays for THz modulation is demonstrated. Analytical modelling based on full-wave techniques and multipole theory exhibits excellent consistent with the experimental observations and reveals that the intrinsic resonance mode at 0.75 THz is dominated by an electric response. The resonant behavior can be effectively tuned by controlling the channel conductivity through an external bias. Such metal/oxide thin-film transistor based controllable metamaterials are energy saving, low cost, large area and ready for mass-production, which are expected to be widely used in future THz imaging, sensing, communications and other applications.

  5. Galphimine-B modifies electrical activity of ventral tegmental area neurons in rats.

    Science.gov (United States)

    Tortoriello, J; Ortega, A; Herrera-Ruíz, M; Trujillo, J; Reyes-Vázquez, C

    1998-05-01

    Galphimine-B (G-B) is a bioactive compound isolated from the plant Galphimia glauca Cav. (Malpighiaceae) with central nervous system depressant properties previously described. In the present study, extracellular spiking activity records in either somatosensorial cortex or ventral tegmental area (VTA) neurons, were performed in rats after i.p. or local administration of G-B. None of the cortical neurons displayed significant changes induced by any of the applied doses. In VTA cells, two patterns of electrical discharge were recorded, bursting (57%) and nonbursting (43%) types. Systemic administration of G-B induced excitatory effects in neurons with a bursting firing pattern and mixed responses on nonbursting units. When this compound was applied locally by microiontophoresis, most of the bursting and nonbursting spiking neurons showed a firing depression and only a few of the nonbursting neurons showed an increment of discharge frequency. These results are important since VTA is a major dopaminergic center responsible for the innervation of the prefrontal cortex, nucleus accumbens and entorhinal region. These areas are targets for the action of antipsychotic drugs.

  6. Effect of Heat and Electricity Storage and Reliability on Microgrid Viability: A Study of Commercial Buildings in California and New York States

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Siddiqui, Afzal; Lai, Judy; Coffey, Brian; Aki, Hirohisa

    2009-03-10

    Berkeley Lab has for several years been developing methods for selection of optimal microgrid systems, especially for commercial building applications, and applying these methods in the Distributed Energy Resources Customer Adoption Model (DER-CAM). This project began with 3 major goals: (1) to conduct detailed analysis to find the optimal equipment combination for microgrids at a few promising commercial building hosts in the two favorable markets of California and New York, (2) to extend the analysis capability of DER-CAM to include both heat and electricity storage, and (3) to make an initial effort towards adding consideration of power quality and reliability (PQR) to the capabilities of DER-CAM. All of these objectives have been pursued via analysis of the attractiveness of a Consortium for Electric Reliability Technology Solutions (CERTS) Microgrid consisting of multiple nameplate 100 kW Tecogen Premium Power Modules (CM-100). This unit consists of an asynchronous inverter-based variable speed internal combustion engine genset with combined heat and power (CHP) and power surge capability. The essence of CERTS Microgrid technology is that smarts added to the on-board power electronics of any microgrid device enables stable and safe islanded operation without the need for complex fast supervisory controls. This approach allows plug and play development of a microgrid that can potentially provide high PQR with a minimum of specialized site-specific engineering. A notable feature of the CM-100 is its time-limited surge rating of 125 kW, and DER-CAM capability to model this feature was also a necessary model enhancement.

  7. New Progress in Reliability Field of Electrical Products and Electrical Contacts:Review of the 5th ICREPEC%电工产品与电接触可靠性领域研究新进展--第五届电工产品可靠性与电接触国际会议论文综述

    Institute of Scientific and Technical Information of China (English)

    陈洪科; 陆宁懿

    2015-01-01

    介绍了第五届电工产品可靠性与电接触国际会议发表论文的情况;通过对相关论文内容的介绍,评述了电工产品与电接触可靠性领域研究的进展与特点。%This paper introduces the 5th International Conference on Reliability of Electrical Products and Electrical Contacts (ICREPEC). According to the papers collected, new progress and features in reliability field of electrical products and electrical contacts are summarized.

  8. Large area growth and electrical properties of p-type WSe2 atomic layers.

    Science.gov (United States)

    Zhou, Hailong; Wang, Chen; Shaw, Jonathan C; Cheng, Rui; Chen, Yu; Huang, Xiaoqing; Liu, Yuan; Weiss, Nathan O; Lin, Zhaoyang; Huang, Yu; Duan, Xiangfeng

    2015-01-14

    Transition metal dichacogenides represent a unique class of two-dimensional layered materials that can be exfoliated into single or few atomic layers. Tungsten diselenide (WSe(2)) is one typical example with p-type semiconductor characteristics. Bulk WSe(2) has an indirect band gap (∼ 1.2 eV), which transits into a direct band gap (∼ 1.65 eV) in monolayers. Monolayer WSe(2), therefore, is of considerable interest as a new electronic material for functional electronics and optoelectronics. However, the controllable synthesis of large-area WSe(2) atomic layers remains a challenge. The studies on WSe(2) are largely limited by relatively small lateral size of exfoliated flakes and poor yield, which has significantly restricted the large-scale applications of the WSe(2) atomic layers. Here, we report a systematic study of chemical vapor deposition approach for large area growth of atomically thin WSe(2) film with the lateral dimensions up to ∼ 1 cm(2). Microphotoluminescence mapping indicates distinct layer dependent efficiency. The monolayer area exhibits much stronger light emission than bilayer or multilayers, consistent with the expected transition to direct band gap in the monolayer limit. The transmission electron microscopy studies demonstrate excellent crystalline quality of the atomically thin WSe(2). Electrical transport studies further show that the p-type WSe(2) field-effect transistors exhibit excellent electronic characteristics with effective hole carrier mobility up to 100 cm(2) V(-1) s(-1) for monolayer and up to 350 cm(2) V(-1) s(-1) for few-layer materials at room temperature, comparable or well above that of previously reported mobility values for the synthetic WSe(2) and comparable to the best exfoliated materials.

  9. RSPP: A Reliable, Searchable and Privacy-Preserving e-Healthcare System for Cloud-Assisted Body Area Networks

    OpenAIRE

    Yang, Lei; Zheng, Qingji; Fan, Xinxin

    2017-01-01

    The integration of cloud computing and Internet of Things (IoT) is quickly becoming the key enabler for the digital transformation of the healthcare industry by offering comprehensive improvements in patient engagements, productivity and risk mitigation. This paradigm shift, while bringing numerous benefits and new opportunities to healthcare organizations, has raised a lot of security and privacy concerns. In this paper, we present a reliable, searchable and privacy-preserving e-healthcare s...

  10. Can a deterministic spatial microsimulation model provide reliable small-area estimates of health behaviours? An example of smoking prevalence in New Zealand.

    Science.gov (United States)

    Smith, Dianna M; Pearce, Jamie R; Harland, Kirk

    2011-03-01

    Models created to estimate neighbourhood level health outcomes and behaviours can be difficult to validate as prevalence is often unknown at the local level. This paper tests the reliability of a spatial microsimulation model, using a deterministic reweighting method, to predict smoking prevalence in small areas across New Zealand. The difference in the prevalence of smoking between those estimated by the model and those calculated from census data is less than 20% in 1745 out of 1760 areas. The accuracy of these results provides users with greater confidence to utilize similar approaches in countries where local-level smoking prevalence is unknown.

  11. Intra-rater and Inter-rater Reliability of Rehabilitative Ultrasound Imaging of Multifidus Muscle Thickness, Cross Section Area and Bladder Wall Displacement in Multiparous Women

    Directory of Open Access Journals (Sweden)

    Zahra Teymuri

    2016-03-01

    Full Text Available Background. Pregnancy related changes can affect the role of multifidus (MF and pelvic floor muscles (PFM in the spinal stability and load transfer mechanism. Rehabilitative ultrasound imaging (RUSI is a powerful tool that provides unavailable information about the myofascial system. Objective. This study aimed to determine intra-rater and inter-rater reliability of ultrasound imaging in the measurement of MF thickness, cross section area (CSA and bladder wall displacement as a reflection of PFM action in multiparous healthy women. Design.A single-group repeated measures reliability study was conducted. Methods. Ten healthy multiparous women (mean age=35.36 SD=7.71 participated in this study. Bladder wall displacement in the transverse plan through trans-abdominal (TA approach, MF muscle thickness at rest and during contralateral arm lift (CAL and MF muscle CSA were obtained by using RUSI. Infraclass correlation coefficient (ICC with 95% confidence interval (CI, standard error of measurement (SEM and minimal detectable change (MDC were calculated for all variables. Results: ICC values with 95% CI showed that bladder wall displacement has high intra-rater (ICC: 0.91-0.99 and high inter-rater reliability (ICC: 0.93-0.96, MF muscle thickness has good to high intra-rater (ICC: ranged from 0.85 to 0.98 and good to high inter-rater reliability (ICC ranged from0.73 to 0.98 and MF muscle CSA has good to high intra-rater (ICC: 0.78-0.86 and fair inter-rater reliability (ICC: 0.54-0.61. SEMs ranged from 0.69 to 3.98 mm and MDCs ranged from 1.92 to 11.03 mm. Limitation.The number of delivery was not equal between subjects. Conclusions. RUSI is a reliable method in measurement of bladder wall displacement, MF muscle thickness and CSA in multiparous women.

  12. Small nuclear power reactor emergency electric power supply system reliability comparative analysis; Analise da confiabilidade do sistema de suprimento de energia eletrica de emergencia de um reator nuclear de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Bonfietti, Gerson

    2003-07-01

    This work presents an analysis of the reliability of the emergency power supply system, of a small size nuclear power reactor. Three different configurations are investigated and their reliability analyzed. The fault tree method is used as the main tool of analysis. The work includes a bibliographic review of emergency diesel generator reliability and a discussion of the design requirements applicable to emergency electrical systems. The influence of common cause failure influences is considered using the beta factor model. The operator action is considered using human failure probabilities. A parametric analysis shows the strong dependence between the reactor safety and the loss of offsite electric power supply. It is also shown that common cause failures can be a major contributor to the system reliability. (author)

  13. Impacts of Western Area Power Administration`s power marketing alternatives on retail electricity rates and utility financial viability

    Energy Technology Data Exchange (ETDEWEB)

    Bodmer, E.; Fisher, R.E.; Hemphill, R.C.

    1995-03-01

    Changes in power contract terms for customers of Western`s Salt Lake City Area Office affect electricity rates for consumers of electric power in Arizona, Colorado, Nevada, New Mexico, Utah, and Wyoming. The impacts of electricity rate changes on consumers are studied by measuring impacts on the rates charged by individual utility systems, determining the average rates in regional areas, and conducting a detailed rate analysis of representative utility systems. The primary focus is an evaluation of the way retail electricity rates for Western`s preference customers vary with alternative pricing and power quantity commitment terms under Western`s long-term contracts to sell power (marketing programs). Retail rate impacts are emphasized because changes in the price of electricity are the most direct economic effect on businesses and residences arising from different Western contractual and operational policies. Retail rates are the mechanism by which changes in cost associated with Western`s contract terms are imposed on ultimate consumers, and rate changes determine the dollar level of payments for electric power incurred by the affected consumers. 41 figs., 9 tabs.

  14. Analysis Of Soil NPK Ph And Electrical Conductivity At Adham Area- Renk Upper Nile State

    Directory of Open Access Journals (Sweden)

    Abubaker Haroun Mohamed Adam

    2015-08-01

    Full Text Available ABSTRACT The objectives of this study were to investigate soil type potentiality and reaction in relation to the scattered remaining vegetation species and to quantify soil suitability for growing field crops. Adham area witnessed serious land degradation due to the rapid expansion of Rain-fed Mechanized Farming and overgrazing. Consequently the low crop yield enforced the local communities to shift to the alternative sources of income generating activities particularly those related to forest products like charcoal making firewood production logging and tree lobbing. By using Randomized Complete Block Design RCBD with emphasizes on Macro nutrients particularly the Nitrogen Phosphorous and potassium NPK in addition to soil pH and Electrical Conductivity EC. random soil samples each with three levels of depths 0 - 15 15 - 30 30 - 45 cm. were collected. All collected data were analyzed in the laboratory. The result of revealed several types of soils including the cracking and non -cracking clay sandy and red soils. The result of statistical analysis depicted variability in NPK pH and EC between the different locations and soil depths. Furthermore the result showed an association between some studied soil attributes and the spatial distribution of the vegetation species. Rational use through participatory approach is recommended for natural resources management conservation and sustainability. Moreover further study using space technology also recommended.

  15. Validating computationally predicted TMS stimulation areas using direct electrical stimulation in patients with brain tumors near precentral regions

    Directory of Open Access Journals (Sweden)

    Alexander Opitz

    2014-01-01

    Full Text Available The spatial extent of transcranial magnetic stimulation (TMS is of paramount interest for all studies employing this method. It is generally assumed that the induced electric field is the crucial parameter to determine which cortical regions are excited. While it is difficult to directly measure the electric field, one usually relies on computational models to estimate the electric field distribution. Direct electrical stimulation (DES is a local brain stimulation method generally considered the gold standard to map structure–function relationships in the brain. Its application is typically limited to patients undergoing brain surgery. In this study we compare the computationally predicted stimulation area in TMS with the DES area in six patients with tumors near precentral regions. We combine a motor evoked potential (MEP mapping experiment for both TMS and DES with realistic individual finite element method (FEM simulations of the electric field distribution during TMS and DES. On average, stimulation areas in TMS and DES show an overlap of up to 80%, thus validating our computational physiology approach to estimate TMS excitation volumes. Our results can help in understanding the spatial spread of TMS effects and in optimizing stimulation protocols to more specifically target certain cortical regions based on computational modeling.

  16. Validating computationally predicted TMS stimulation areas using direct electrical stimulation in patients with brain tumors near precentral regions.

    Science.gov (United States)

    Opitz, Alexander; Zafar, Noman; Bockermann, Volker; Rohde, Veit; Paulus, Walter

    2014-01-01

    The spatial extent of transcranial magnetic stimulation (TMS) is of paramount interest for all studies employing this method. It is generally assumed that the induced electric field is the crucial parameter to determine which cortical regions are excited. While it is difficult to directly measure the electric field, one usually relies on computational models to estimate the electric field distribution. Direct electrical stimulation (DES) is a local brain stimulation method generally considered the gold standard to map structure-function relationships in the brain. Its application is typically limited to patients undergoing brain surgery. In this study we compare the computationally predicted stimulation area in TMS with the DES area in six patients with tumors near precentral regions. We combine a motor evoked potential (MEP) mapping experiment for both TMS and DES with realistic individual finite element method (FEM) simulations of the electric field distribution during TMS and DES. On average, stimulation areas in TMS and DES show an overlap of up to 80%, thus validating our computational physiology approach to estimate TMS excitation volumes. Our results can help in understanding the spatial spread of TMS effects and in optimizing stimulation protocols to more specifically target certain cortical regions based on computational modeling.

  17. Power electronics reliability analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Mark A.; Atcitty, Stanley

    2009-12-01

    This report provides the DOE and industry with a general process for analyzing power electronics reliability. The analysis can help with understanding the main causes of failures, downtime, and cost and how to reduce them. One approach is to collect field maintenance data and use it directly to calculate reliability metrics related to each cause. Another approach is to model the functional structure of the equipment using a fault tree to derive system reliability from component reliability. Analysis of a fictitious device demonstrates the latter process. Optimization can use the resulting baseline model to decide how to improve reliability and/or lower costs. It is recommended that both electric utilities and equipment manufacturers make provisions to collect and share data in order to lay the groundwork for improving reliability into the future. Reliability analysis helps guide reliability improvements in hardware and software technology including condition monitoring and prognostics and health management.

  18. Plane polymer configurations enclosing a fixed area in an electric field: generating functional and statistical mechanical properties

    NARCIS (Netherlands)

    Khandekar, D.C.; Wiegel, F.W.

    1993-01-01

    The statistical mechanical properties of plane polymer configurations which enclose a fixed area and are subject to an external electric field are investigated. For this purpose an exact expression for the generating functional is obtained and subsequently used to derive: (a) the distribution functi

  19. Cost Reduction Ability by Electricity Tariff Selection for Construction Facilities Located in Non-price Areas

    Directory of Open Access Journals (Sweden)

    Makasheva Svetlana

    2016-01-01

    Full Text Available State of the art in the tariff type selection in the retail and the wholesale electricity market for construction or reconstruction facilities located at Far East are considered. As a management solution the electricity tariff’s selection for enterprises at stage of construction or reconstruction is accented.

  20. Contribution in the area of harmonics in electric power systems; Contribuicoes na area de harmonicos em sistemas eletricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Aloisio de

    1989-07-01

    A general approach of the state of art of the harmonic generation, its sources, its limits, its measurement methods and its effects on the electric system components is presented. This thesis shows that this is an open field to research, modelling and solutions. It also helps towards the investigation of the effects caused by harmonics on the conventional KWh energy meters and on potential and current transformers. It presents the basis for the development and construction of prototypes to be utilized in the generation and measurement of harmonics. Finally a practical approach has been given to calculate the equivalent harmonic impedance as seen by a giving consumer. (author)

  1. Short trains of intra-epidermal electrical stimulation to elicit reliable behavioral and electrophysiological responses to the selective activation of nociceptors in humans.

    Science.gov (United States)

    Mouraux, André; Marot, Emilie; Legrain, Valéry

    2014-02-21

    Currently, the study of nociception in humans relies mainly on thermal stimulation of heat-sensitive nociceptive afferents. To circumvent some limitations of thermal stimulation, it was proposed that intra-epidermal electrical stimulation (IES) could be used as an alternative method to activate nociceptors selectively. The selectivity of IES relies on the fact that it can generate a very focal electrical current and, thereby, activate nociceptive free nerve endings located in the epidermis without concomitantly activating non-nociceptive mechanoreceptors located more deeply in the dermis. However, an important limitation of IES is that it is selective for nociceptors only when very low current intensities are used. At these intensities, the stimulus generates a very weak percept, and the signal-to-noise ratio of the elicited evoked potentials (EPs) is very low. To circumvent this limitation, it was proposed that the strength of the nociceptive afferent volley could be increased through temporal summation, using short trains of repeated IES. Here, we characterized the intensity of perception and EPs elicited by trains of 2, 3 and 4 IES delivered using a 5-ms inter-stimulus interval. We found that both the intensity of perception and the magnitude of EPs significantly increased with the number of pulses. In contrast, the latency of the elicited EPs was not affected by the number of pulses, indicating that temporal summation did not affect the type of activated fibers and, therefore, that trains of IES can be used to increase the reliability of stimulus-evoked responses while still preserving its selectivity for nociceptors.

  2. Is the illite group the cause of high electrical conductivityin certain lithospheric areas?

    Directory of Open Access Journals (Sweden)

    M. Muschietti

    1998-06-01

    Full Text Available This article discusses the problem of the mineralogical-petrographic interpretation of the "anomalous" conductive layer inside the lithosphere, which has resulted from electromagnetic deep soundings. Three situations can be found: 1 a resistivity of less than 1 ? ·m in the Very High Conductivity Layer (VHCL; 2 a resistivity of 1÷100 ? ·m in the High Conductivity Layer (HCL; 3 a resistivity of 102 ÷ 103 ? ·m in the Continental Lower Crust (CLC. We have focused our attention on the HCL because of its widespread distribution. Most authors attribute HCL conductivity to the presence of salt water or graphitic materials, that are uniformly and continuously distributed inside rocks. Other hypotheses from the literature are the presence of oxides and/or sulphides, rock melting, and brine-bearing rocks. Each one of these elements can cause high electrical conductivity, depending on the petrophysical conditions, but much discussion involves the necessary physical continuity of the conductive elements. We forward one more hypothesis as follows. By means of experiments on rock samples from different geographical and deep areas, under simulated in situ physical conditions (e.g., pressure, temperature, saturation, we have found resistivity values similar to the in situ ones. Chemical, mineralogical, and petrographic analyses have shown the presence of large amounts of phyllosilicate minerals, such as illite. These minerals act in two ways: they produce the physical continuity of associated conductive minerals, and they decrease the resistivity of rocks. This second hypothesis is consistent with both the very widespread diffusion of illite inside the Earth's crust, and with the good conductivity found in depth.

  3. 76 FR 66220 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards

    Science.gov (United States)

    2011-10-26

    ... approval by the North American Electric Reliability Corporation (NERC), the Electric Reliability... proposes to approve the related Violation Risk Factors and Violation Severity Levels, implementation plan... of Electric Reliability, Division of Reliability Standards, Federal Energy Regulatory Commission,...

  4. Solar battery power supply: A reliable power supply system for nursing clinic in Australia`s remote areas

    Energy Technology Data Exchange (ETDEWEB)

    Zahedi, A. [Monash Univ., Caulfield (Australia). Div. of Electrical and Computer Systems Engineering

    1997-12-31

    Design and performance investigation of a new solar-battery system to power health clinics in Australia`s remote and isolated areas is a research project being conducted in the Department. The objective of this paper is to present the solar-battery system and to discuss the design factors of the system.

  5. Power Quality and Reliability Project

    Science.gov (United States)

    Attia, John O.

    2001-01-01

    One area where universities and industry can link is in the area of power systems reliability and quality - key concepts in the commercial, industrial and public sector engineering environments. Prairie View A&M University (PVAMU) has established a collaborative relationship with the University of'Texas at Arlington (UTA), NASA/Johnson Space Center (JSC), and EP&C Engineering and Technology Group (EP&C) a small disadvantage business that specializes in power quality and engineering services. The primary goal of this collaboration is to facilitate the development and implementation of a Strategic Integrated power/Systems Reliability and Curriculum Enhancement Program. The objectives of first phase of this work are: (a) to develop a course in power quality and reliability, (b) to use the campus of Prairie View A&M University as a laboratory for the study of systems reliability and quality issues, (c) to provide students with NASA/EPC shadowing and Internship experience. In this work, a course, titled "Reliability Analysis of Electrical Facilities" was developed and taught for two semesters. About thirty seven has benefited directly from this course. A laboratory accompanying the course was also developed. Four facilities at Prairie View A&M University were surveyed. Some tests that were performed are (i) earth-ground testing, (ii) voltage, amperage and harmonics of various panels in the buildings, (iii) checking the wire sizes to see if they were the right size for the load that they were carrying, (iv) vibration tests to test the status of the engines or chillers and water pumps, (v) infrared testing to the test arcing or misfiring of electrical or mechanical systems.

  6. Reliability and relative validity of fish consumption data obtained in an exposure assessment study among Montreal-area sportfishers

    Energy Technology Data Exchange (ETDEWEB)

    Shatenstein, B. [Sante au Travail et Environnementale, Montreal, Quebec (Canada). Regie Regionale de la Sante et des Services Sociaux de Montreal-Centre]|[Univ. de Montreal, Quebec (Canada) Dept. de Nutrition; Kosatsky, T.; Nadon, S. [Sante au Travail et Environnementale, Montreal, Quebec (Canada). Regie Regionale de la Sante et des Services Sociaux de Montreal-Centre; Lussier-Cacan, S. [Inst. de Recherches Cliniques de Montreal, Quebec (Canada); Weber, J.P. [Centre de Toxicologie du Quebec, Ste. Foy, Quebec (Canada)

    1999-02-01

    A two-season exercise was undertaken in 29 high-level sportfish consumers to evaluate the reliability and accuracy of study instruments. Fishers were invited to participate after completing the main study interview (Time 1) in fall 1995 or winter 1996. Over a 4-week period, they provided a nonconsecutive 7-day weighed food record, kept a fish consumption calendar, and responded to a shortened version of the Time 1 instrument at the end of this period (Time 2). A second blood sample (at Time 2) was analyzed for whole blood mercury (Hg) and the omega-3 fatty acids eicosapentanoic acid (EPA) and docosahexaenoic acid (DHA) in plasma and erythrocytes. Identical questions were compared in the Time 1 and Time 2 instruments. Reported sportfish consumption assessed by the different instruments was subjected to nutrient analysis. Three estimates of exposure to the target substances were derived from the dietary intake estimates and correlated with their respective Time 2 plasma (EPA, DHA) or blood (Hg) values, and with a kinetically derived interval-specific plasma/blood uptake value. Remarkable similarities were observed for the data derived from like questions in the Time 1 and 2 questionnaires in both seasons. However, frank discrepancies between some portion size estimates and measured values may signal cause for concern.

  7. Experimental study on electrical conductivity of dunite at high temperature and pressure—— The evidence of electrical conductivity of cold mantle in the Gaize-Lugu area

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The electrical conductivities of the dunite from the Qinghai-Xizang (Tibetan) Plateau were measured with the impedance spectra method at 1.0 -4.0 GPa and 643-1093 K. The experimental results indicated that activation enthalpies of the dunite are smaller than 0.9 eV, the conduction mechanism in dunite may be attributed to the mixed electrical conduction involving grain interiors and boundaries. On the basis of the results of this experiment, we can deduce that there exists cold mantle in the area of Gaize- Lugu in the Qinghai-Xizang (Tibetan) Plateau by reverse methods from the magnetotelluric sounding data (conductivity-depths profile) available for western Tibet. The result provides the present cold mantle viewpoint with strong proof on the basis of high temperature and pressure experiments.

  8. Steam-Electric Power-Plant-Cooling Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sonnichsen, J.C.; Carlson, H.A.; Charles, P.D.; Jacobson, L.D.; Tadlock, L.A.

    1982-02-01

    The Steam-Electric Power Plant Cooling Handbook provides summary data on steam-electric power plant capacity, generation and number of plants for each cooling means, by Electric Regions, Water Resource Regions and National Electric Reliability Council Areas. Water consumption by once-through cooling, cooling ponds and wet evaporative towers is discussed and a methodology for computation of water consumption is provided for a typical steam-electric plant which uses a wet evaporative tower or cooling pond for cooling.

  9. Assessment of access to electricity and the socio-economic impacts in rural areas of developing countries

    Energy Technology Data Exchange (ETDEWEB)

    Kanagawa, Makoto; Nakata, Toshihiko [Department of Management Science and Technology, Graduate School of Engineering, Tohoku University, Aoba-Yama 6-6-11-815, Sendai 980-8579 (Japan)

    2008-06-15

    The purpose of this study is to reveal relations between access to electricity and advancement in a socio-economic condition in rural areas of developing countries. Recently, multi-dimensional aspects of poverty, for example, economy, education, and health, has been increasingly focused on, and access to modern energy such as electricity is one possible solution. As a case study, we have analyzed unelectrified rural areas in Assam state, India. We have developed an energy-economic model in order to analyze the possibility of electrification through dissemination of electric lighting appliances as well as applied multiple regression analysis to estimate the socio-economic condition, a literacy rate above 6 years old, in the areas. As a result of the case study, the household electrification rate, the 1000 km{sup 2} road density, and sex ratio have been chosen as the explanatory variables of the literacy rate. Moreover, the model analysis shows that complete household electrification will be achieved by the year 2012. In combination with the multiple regression and model analysis, the literacy rate in Assam may increase to 74.4% from 63.3%. (author)

  10. Application of valve-regulated lead-acid batteries for storage of solar electricity in stand-alone photovoltaic systems in the northwest areas of China

    Science.gov (United States)

    Hua, Shounan; Zhou, Qingshen; Kong, Delong; Ma, Jianping

    Photovoltaic (PV) installations for solar electric power generation are being established rapidly in the northwest areas of China, and it is increasingly important for these power systems to have reliable and cost effective energy storage. The lead-acid battery is the more commonly used storage technology for PV systems due to its low cost and its wide availability. However, analysis shows that it is the weakest component of PV power systems. Because the batteries can be over discharged, or operated under partial state of charge (PSOC), their service life in PV systems is shorter than could be expected. The working conditions of batteries in remote area installations are worse than those in situations where technical support is readily available. Capacity-loss in lead-acid batteries operated in remote locations often occurs through sulfation of electrodes and stratification of electrolyte. In northwest China, Shandong Sacred Sun Power Sources Industry Co. Ltd. type GFMU valve-regulated lead-acid (VRLA) batteries are being used in PV power stations. These batteries have an advanced grid structure, superior leady paste, and are manufactured using improved plate formation methods. Their characteristics, and their performance in PV systems, are discussed in this paper. The testing results of GFMU VRLA batteries in the laboratory have shown that the batteries could satisfy the demands of the International Electrotechnical Commission (IEC) standards for PV systems.

  11. 电动汽车用异步电机驱动控制系统可靠性分析%Reliability Analysis of Asynchronous Motors Driving and Controlling System in Electric Vehicle

    Institute of Scientific and Technical Information of China (English)

    李强; 王永全; 付瑶琴

    2014-01-01

    电机驱动控制系统是电动汽车的心脏,其可靠性直接影响着电动汽车的安全性。分析了驱动控制系统的主要故障模式,其薄弱环节为电机轴承系统、绝缘系统,及直流母线电容、IGBT等电子元器件。在此基础上建立可靠性模型。采用元器件应力分析法预计电动汽车电机驱动系统的可靠性。%The motor driving and controlling system is the heart of the electric vehicle, whose reliability directly affects the safety of the electric vehicle. The main failure pattern of the motor driving and controlling system was analyzed, in which the motor bearing systems, insulation systems, DC bus capacitors, IGBT and other electronic components are the weak links. On the basis of the analysis, the reliability model was established. Based on the established reliability model, the reliability of motor driving and controlling system in electric vehicles was estimated by the component stress analysis method.

  12. Multi-Area Predictive Control for Combined Electricity and Natural Gas Systems

    NARCIS (Netherlands)

    Arnold, M.; Negenborn, R.R.; Andersson, G.; De Schutter, B.

    2009-01-01

    The optimal operation of an integrated electricity and natural gas system is investigated. The couplings between these two systems are modeled by energy hubs, which serve as interface between the loads and the transmission infrastructures. Previously, we have applied a distributed control scheme to

  13. Applying of Electrical Imaging Survey (EIS) to Evaluate Leachate Pollution in Underground Area of Informal Landfill

    DEFF Research Database (Denmark)

    Du, Song; Wang, Di; Mou, Zishen;

    2014-01-01

    An informal landfill is an open dump that pollutes the underground environment because it lacks an impervious liner. The leakage of such a landfill is unidirectional and thus difficult to directly test. This study uses electrical imaging survey to evaluate the pollution of the underground environ...

  14. Acidic Barren Slope Profiling using Electrical Resistivity Imaging (ERI) at Ayer Hitam area Johor, Malaysia

    Science.gov (United States)

    Azhar, A. T. S.; Hazreek, Z. A. M.; Aziman, M.; Haimi, D. S.; Hafiz, Z. M.

    2016-04-01

    Recently, non-destructive method such as the electrical resistivity technique has become increasingly popular in engineering, environmental, mining and archeological studies nowadays. This method was popular in subsurface profiling due to its ability to replicate the images of the subsurface indirectly. The soil slope found in Batu Pahat, specifically in Ayer Hitam, is known to be problematic due to its barren condition. This location is believed to contain futile soil due to its difficulty in supporting the growth of vegetations. In the past, acidic barren slope assessment using non-destructive method was rarely being used due to several reasons related to the equipment and knowledge constraints. Hence, this study performed an electrical resistivity imaging using ABEM Terrameter LS in order to investigate the acidic barren slope conditions. Field data acquisition was based on Schlumberger and Wenner arrays while RES2DINV software was used to analyze and generate a 2-D model of the problematic subsurface profile. Based on electrical resistivity results, it was found that the acidic barren slope studied consists of two main zones representing residual soil (electrical resistivity value = 10 - 600 Ωm) and shale (electrical resistivity value = 20 - 2000 Ωm). The results of resistivity value were correlated with the physical mapping and the in situ mackintosh probe test for verification purposes. It was found that the maximum depth of the mackintosh probe test was 1.8 m due to its ground penetration limitation. However, the results of the resistivity section managed to achieve greater depth up to 40 m. Hence, the correlation between electrical resistivity and mackintosh probe results can only be performed at certain depth of the acidic barren slope profile in contrast with the physical mapping which able to define the whole section of the barren soil slope structure. Finally, a good match of electrical resistivity results calibrated with mackintosh and physical

  15. Rainfall yield characteristics of electrical storm observed in the Spanish Basque Country area during the period 1992 1996

    Science.gov (United States)

    Ezcurra, A.; Saenz, J.; Ibarra-Berastegi, G.; Areitio, J.

    2008-08-01

    This paper is focused on the study of rainfall yield characteristics of electrical storms observed over the Northern Iberian Peninsula during 1992-1996. To this aim Principal Components Analysis (PCA) and Self-Organizing Maps (SOM) method have been used. The SOM method is a group of artificial neural networks based on the topological properties of the human brain. Results clearly suggest that there exist three different meteorological patterns that are linked to the characteristics of electrical events found in the study area. In winter, most of the electrical events are formed under oceanic advection (NW air fluxes). On these cases, mean rainfall yield estimates reach values of 700 10 4 m 3 per cloud to ground lightning flash (CG flash). During summer most frequent electrical storms are associated to local instability shooting by surface heating with advection of humidity coming from the Iberian Peninsula. Under these meteorological situations, rain is scarcer if compared with oceanic events but lightning CG counts reach the maximum values found in the area (about 10 CG counts per 20 × 20 km 2 and day) giving this way the smallest rainfall yield with a mean value of 15 10 4 m 3 per CG flash. Iberian air fluxes associated with cold air in upper parts of the atmosphere represent the third meteorological pattern found. This pattern is most common in spring and autumn but is not unusual in the rest of the seasons. In those cases mean rainfall yield in the area is about 150 10 4 m 3 per CG flash. In all electrical episodes K instability index is greater than 15 °C but in the most lightning producing events, this index reaches in the area values greater than 24 °C. PCA results pointed out that there exists a relationship between rain and CG counts expressed by the first principal component computed from standardized data. However, we must notice that no event is solely linked to this axis, since a seasonal influence which decreases lightning production when rain

  16. 基于Pareto支配的MPRM电路面积与可靠性优化%Pareto Do minance Based Area and Reliability Opti mization of MPRM Circuits

    Institute of Scientific and Technical Information of China (English)

    卜登立; 江建慧

    2016-01-01

    针对MPRM(Mixed-Polarity Reed-Muller)电路的面积与可靠性折中优化问题,在逻辑级建立面积估算模型以及电路SER(Soft Error Rate)解析评价模型,并采用Pareto支配概念对MPRM电路进行面积与可靠性多目标优化.通过对MPRM电路的XOR部分进行树形异或门分解,并考虑多个输出之间异或门的共享,建立面积估算模型.采用信号概率和故障传播方法,并考虑电路中的逻辑屏蔽因素以及信号相关性,建立电路SER解析评价模型.根据所提出的面积和SER评价模型,采用极性向量的格雷码序穷举搜索MPRM的极性空间得到MPRM电路面积与可靠性的Pa-reto最优解集,并使用效率因子技术指标选取最终解.MCNC基准电路的实验结果表明,与面积最小MPRM电路相比,所选取的MPRM电路可以在较小面积开销的前提下获得较高电路可靠性.%Area and SER (Soft Error Rate)evaluation models at logic level are proposed for area and reliability opti-mization of MPRM (Mixed-Polarity Reed-Muller)circuits,the trade-off between area and reliability is achieved by using Pareto dominance based multiobjective optimization.The area is computed by decomposing the XOR part of MPRM circuit as trees of XOR gates and counting in XOR gate sharing among multiple outputs.The SER is computed by using signal probability and fault propagation techniques,and taking into account the logic masking effects and correlations among signals in the circuit network.Based on the proposed area and SER evaluation models,the Pareto optimal set for area and SER of MPRM circuit is obtained by using polarity optimization method with Gray code based exhaustive search strategy,the final solution is selected by using a metric called efficiency factor.Experimental results by using a set of benchmark circuits from MCNC show that,in comparison with the MPRM circuits with minimized area,the selected MPRM circuits have improved reliability

  17. Study on Reliability Pricing System in Electricity Market Based on Hierarchical Reliability Service%电力市场下基于分层可靠性服务的可靠性电价体系研究

    Institute of Scientific and Technical Information of China (English)

    张钦; 白建华; 陈立斌

    2011-01-01

    利用基于电量不足期望值贡献系数的方法,并结合可靠性灵敏度分析,将事故备用费用分摊到发电侧和输电侧,并形成了相应的发电侧和输电侧可靠性电价。利用模糊聚类分析方法,根据用户的可靠性服务综合指标要求,将系统中的用户划分为几个层次类别,对每层用户进行归一化处理并用一个虚拟用户来代表该层用户的可靠性服务要求,然后根据各层虚拟用户的可靠性服务要求购买可靠性服务备用并将费用分摊到各个虚拟用户得到用户侧可靠性电价。通过算例仿真表明,所提出的可靠性电价体系能够有效地实现可靠性服务的差别定价。%Utilizing the contribution coefficient based on expected energy not supplied (EENS) and combining reliability sensitivity analysis, the contingency reserve cost is allocated to generation side and transmission side, and corresponding reliability pricings at generation side and transmission side are formed. Using fuzzy clustering analysis and according to customers' requirement on comprehensive index of reliability service the custormers in power grid are divided into several categories belonging to different hierarchies; then the customers in each hierarchy are normalized and a virtual customer is designed to represent the reliability service requirement of custormers in this hierarchy; finally, according to reliability service requirements of virtual customers in different hierarchies the reliability service reserves are purchased and the cost of the bought reliability service reserves is allocated to all virtual customers to obtain the reliability pricing at customer side. The discriminating pricing of reliability service can be effectively implemeted by the proposed reliability pricing system.

  18. 78 FR 38311 - Reliability Technical Conference Agenda

    Science.gov (United States)

    2013-06-26

    ..., Fix, Track, and Report program enhanced reliability? b. What is the status of the NERC Reliability... Energy Regulatory Commission Reliability Technical Conference Agenda Reliability Technical Docket No. AD13-6-000 Conference. North American Electric Docket No. RC11-6-004 Reliability Corporation....

  19. SOLAR WATER DESALINATION SYSTEM WITH CONDENSER WITHOUT USING ELECTRICITY FOR RURAL AREAS

    Directory of Open Access Journals (Sweden)

    Abhijeet Auti

    2013-01-01

    Full Text Available Domestic desalination is a process in which salt water is heated and converted to steam by using parabolic solar concentrator. Solar radiations incident on concentrator are focused at the absorber which contains salt water. The steam is then condensed by the condenser which is designed on the basis of the thermal analysis. Condenser is a basically a water tank with copper tubes immersed in it. The steam flows through the tubes and heat exchange takes place between steam and tank water which absorbs the heat from the steam by converting it to purified water. No electricity is used for the condensation and the equipment is suitable for a small family, having no or limited access to electricity.

  20. Spatial distribution of the electrical potential and ion concentration in the downstream area of atmospheric pressure remote plasma

    Directory of Open Access Journals (Sweden)

    M. V. Mishin

    2014-10-01

    Full Text Available This paper presents the results from an experimental study of the ion flux characteristics behind the remote plasma zone in a vertical tube reaction chamber for atmospheric pressure plasma enhanced chemical vapor deposition. Capacitively coupled radio frequency plasma was generated in pure He and gas mixtures: He–Ar, He–O2, He–TEOS. We previously used the reaction system He–TEOS for the synthesis of self-assembled structures of silicon dioxide nanoparticles. It is likely that the electrical parameters of the area, where nanoparticles have been transported from the synthesis zone to the substrate, play a significant role in the self-organization processes both in the vapor phase and on the substrate surface. The results from the spatial distribution of the electrical potential and ion concentration in the discharge downstream area measured by means of the external probe of original design and the special data processing method are demonstrated in this work. Positive and negatives ions with maximum concentrations of 106–107 cm−3 have been found at 10–80 mm distance behind the plasma zone. On the basis of the revealed distributions for different gas mixtures, the physical model of the observed phenomena is proposed. The model illustrates the capability of the virtual ion emitter formation behind the discharge gap and the presence of an extremum of the electrical potential at the distance of approximately 10−2–10−1 mm from the grounded electrode.

  1. Regional economic impacts of changes in electricity rates resulting from Western Area Power Administration`s power marketing alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Allison, T.; Griffes, P.; Edwards, B.K.

    1995-03-01

    This technical memorandum describes an analysis of regional economic impacts resulting from changes in retail electricity rates due to six power marketing programs proposed by Western Area Power Administration (Western). Regional economic impacts of changes in rates are estimated in terms of five key regional economic variables: population, gross regional product, disposable income, employment, and household income. The REMI (Regional Impact Models, Inc.) and IMPLAN (Impact Analysis for Planning) models simulate economic impacts in nine subregions in the area in which Western power is sold for the years 1993, 2000, and 2008. Estimates show that impacts on aggregate economic activity in any of the subregions or years would be minimal for three reasons. First, the utilities that buy power from Western sell only a relatively small proportion of the total electricity sold in any of the subregions. Second, reliance of Western customers on Western power is fairly low in each subregion. Finally, electricity is not a significant input cost for any industry or for households in any subregion.

  2. Measurement Practices for Reliability and Power Quality

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, JD

    2005-05-06

    This report provides a distribution reliability measurement ''toolkit'' that is intended to be an asset to regulators, utilities and power users. The metrics and standards discussed range from simple reliability, to power quality, to the new blend of reliability and power quality analysis that is now developing. This report was sponsored by the Office of Electric Transmission and Distribution, U.S. Department of Energy (DOE). Inconsistencies presently exist in commonly agreed-upon practices for measuring the reliability of the distribution systems. However, efforts are being made by a number of organizations to develop solutions. In addition, there is growing interest in methods or standards for measuring power quality, and in defining power quality levels that are acceptable to various industries or user groups. The problems and solutions vary widely among geographic areas and among large investor-owned utilities, rural cooperatives, and municipal utilities; but there is still a great degree of commonality. Industry organizations such as the National Rural Electric Cooperative Association (NRECA), the Electric Power Research Institute (EPRI), the American Public Power Association (APPA), and the Institute of Electrical and Electronics Engineers (IEEE) have made tremendous strides in preparing self-assessment templates, optimization guides, diagnostic techniques, and better definitions of reliability and power quality measures. In addition, public utility commissions have developed codes and methods for assessing performance that consider local needs. There is considerable overlap among these various organizations, and we see real opportunity and value in sharing these methods, guides, and standards in this report. This report provides a ''toolkit'' containing synopses of noteworthy reliability measurement practices. The toolkit has been developed to address the interests of three groups: electric power users, utilities, and

  3. Wind-solar-battery hybrid system for electricity generation in remote areas. An alternative for conventional rural grid extension; Sistema hibrido eolico-solar-bateria para geracao de energia eletrica em locais remotos. Uma alternativa a extensao da rede convencional em meios rurais

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alexandre Carlos A.; Feitosa, Everaldo A.N. [Pernambuco Univ., Recife, PE (Brazil). Centro de Tecnologia e Geociencias. Centro Brasileiro de Energia Eolica

    1999-07-01

    This paper presents a hybrid system (installed at test area of the Brazilian Center for Eolian Energy - CBEE) consisting of wind turbine, photovoltaic panels and a battery bank, with a large reliability. This system is presented as an alternative to the extension of the conventional electric power distribution network through the Brazilian northeast area communities. Simulations of the system are presented, by using the HYBRID2 computer code, developed by the Massachusetts University jointly with researchers from the CBEE. A preliminary economic analysis is conducted by comparing the hybrid system parameters with parameters of the conventional electric power distribution network.

  4. Interpretation of electrical resistivity and shallow seismic reflection profiles, Whirlwind Valley and Horse Heaven areas, Beowawe KGRA, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C.

    1979-12-01

    Numerical modeling and analysis of surface electrical and seismic data from the Beowawe KGRA, north-central Nevada, permit extrapolation of mapped geologic units and structures to approximately a mile (1.6 km) depth from which inferences about the geothermal system can be made. Detailed numerical modeling was complete for 78 line-mi. (125 km) of dipole-dipole resistivity data and includes compensation for topographic effects caused by the Malpais Rim scarp. The interpreted sections have as many as five distinct electrical units, one of which occurs only within the area of hydrothermal alteration along the fault set at the base of the Malpais Rim. The weight-drop seismic reflection data show numerous normal faults sub-parallel to the Malpais Rim within Whirlwind Valley west and southwest of The Geysers.

  5. Salt Lake City Area Integrated Projects Electric Power Marketing. Draft environmental impact statement: Volume 4, Appendixes B-D

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    The Salt Lake City Area Office of the Western Area Power Administration (Western) markets electricity produced at hydroelectric facilities operated by the Bureau of Reclamation. The facilities are known collectively as the Salt Lake City Area Integrated Projects (SLCA/IP) and include dams equipped for power generation on the Green, Gunnison, Rio Grande, and Colorado rivers and on Deer and Plateau creeks in the states of Wyoming, Utah, Colorado, Arizona, and New Mexico. Of these facilities, only the Glen Canyon Unit, the Flaming Gorge Unit, and the Aspinall Unit (which includes Blue Mesa, Morrow Point, and Crystal dams;) are influenced by Western power scheduling and transmission decisions. The EIS alternatives, called commitment-level alternatives, reflect combinations of capacity and energy that would feasibly and reasonably fulfill Westerns firm power marketing responsibilities, needs, and statutory obligations. The viability of these alternatives relates directly to the combination of generation capability of the SLCA/IP with energy purchases and interchange. The economic and natural resource assessments in this environmental impact statement (EIS) include an analysis of commitment-level alternatives. Impacts of the no-action alternative are also assessed. Supply options, which include combinations of electrical power purchases and hydropower operational scenarios reflecting different operations of the dams, are also assessed. The EIS evaluates the impacts of these scenarios relative to socioeconomics, air resources, water resources, ecological resources, cultural resources, land use, recreation, and visual resources.

  6. Hydrostratigraphy and hydrogeology of the western part of Maira area, Khyber Pakhtunkhwa, Pakistan: A case study by using electrical resistivity

    KAUST Repository

    Farid, Asam M.

    2012-06-27

    Hydrostratigraphy and hydrogeology of the Maira vicinity is important for the characterization of aquifer system and developing numerical groundwater flow models to predict the future availability of the water resource. Conventionally, the aquifer parameters are obtained by the analysis of pumping tests data which provide limited spatial information and turn out to be costly and time consuming. Vertical electrical soundings and pump testing of boreholes were conducted to delineate the aquifer system at the western part of the Maira area, Khyber Pakhtun Khwa, Pakistan. Aquifer lithology in the eastern part of the study area is dominated by coarse sand and gravel whereas the western part is characterized by fine sand. An attempt has been made to estimate the hydraulic conductivity of the aquifer system by establishing a relationship between the pumping test results and vertical electrical soundings by using regression technique. The relationship is applied to the area along the resistivity profiles where boreholes are not drilled. Our findings show a good match between pumped hydraulic conductivity and estimated hydraulic conductivity. In case of sparse borehole data, regression technique is useful in estimating hydraulic properties for aquifers with varying lithology. © 2012 Springer Science+Business Media B.V.

  7. Salt Lake City Area Integrated Projects Electric Power Marketing. Draft environmental impact statement: Volume 2, Sections 1-16

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    The Salt Lake City Area Office of the Western Area Power Administration (Western) markets electricity produced at hydroelectric facilities operated by the Bureau of Reclamation. The facilities are known collectively as the Salt Lake City Area Integrated Projects (SLCA/IP) and include dams equipped for power generation on the Green, Gunnison, Rio Grande, and Colorado rivers and on Deer and Plateau creeks in the states of Wyoming, Utah, Colorado, Arizona, and New Mexico. Of these facilities, only the Glen Canyon Unit, the Flaming Gorge Unit, and the Aspinall Unit (which includes Blue Mesa, Morrow Point, and Crystal dams;) are influenced by Western power scheduling and transmission decisions. The EIS alternatives, called commitment-level alternatives, reflect combinations of capacity and energy that would feasibly and reasonably fulfill Westerns firm power marketing responsibilities, needs, and statutory obligations. The viability of these alternatives relates directly to the combination of generation capability of the SLCA/IP with energy purchases and interchange. The economic and natural resource assessments in this environmental impact statement (EIS) include an analysis of commitment-level alternatives. Impacts of the no-action alternative are also assessed. Supply options, which include combinations of electrical power purchases and hydropower operational scenarios reflecting different operations of the dams, are also assessed. The EIS evaluates the impacts of these scenarios relative to socioeconomics, air resources, water resources, ecological resources, cultural resources, land use, recreation, and visual resources.

  8. Salt Lake City Area Integrated Projects Electric Power Marketing. Draft environmental impact statement: Volume 3, Appendix A

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    The Salt Lake City Area Office of the Western Area Power Administration (Western) markets electricity produced at hydroelectric facilities operated by the Bureau of Reclamation. The facilities are known collectively as the Salt Lake City Area Integrated Projects (SLCA/IP) and include dams equipped for power generation on the Green, Gunnison, Rio Grande, and Colorado rivers and on Deer and Plateau creeks in the states of Wyoming, Utah, Colorado, Arizona, and New Mexico. Of these facilities, only the Glen Canyon Unit, the Flaming Gorge Unit, and the Aspinall Unit (which includes Blue Mesa, Morrow Point, and Crystal dams;) are influenced by Western power scheduling and transmission decisions. The EIS alternatives, called commitment-level alternatives, reflect combinations of capacity and energy that would feasibly and reasonably fulfill Westerns firm power marketing responsibilities, needs, and statutory obligations. The viability of these alternatives relates directly to the combination of generation capability of the SLCA/IP with energy purchases and interchange. The economic and natural resource assessments in this environmental impact statement (EIS) include an analysis of commitment-level alternatives. Impacts of the no-action alternative are also assessed. Supply options, which include combinations of electrical power purchases and hydropower operational scenarios reflecting different operations of the dams, are also assessed. The EIS evaluates the impacts of these scenarios relative to socioeconomics, air resources, water resources, ecological resources, cultural resources, land use, recreation, and visual resources.

  9. Electrical stimulation of Broca's area enhances implicit learning of an artificial grammar.

    Science.gov (United States)

    de Vries, Meinou H; Barth, Andre C R; Maiworm, Sandra; Knecht, Stefan; Zwitserlood, Pienie; Flöel, Agnes

    2010-11-01

    Artificial grammar learning constitutes a well-established model for the acquisition of grammatical knowledge in a natural setting. Previous neuroimaging studies demonstrated that Broca's area (left BA 44/45) is similarly activated by natural syntactic processing and artificial grammar learning. The current study was conducted to investigate the causal relationship between Broca's area and learning of an artificial grammar by means of transcranial direct current stimulation (tDCS). Thirty-eight healthy subjects participated in a between-subject design, with either anodal tDCS (20 min, 1 mA) or sham stimulation, over Broca's area during the acquisition of an artificial grammar. Performance during the acquisition phase, presented as a working memory task, was comparable between groups. In the subsequent classification task, detecting syntactic violations, and specifically, those where no cues to superficial similarity were available, improved significantly after anodal tDCS, resulting in an overall better performance. A control experiment where 10 subjects received anodal tDCS over an area unrelated to artificial grammar learning further supported the specificity of these effects to Broca's area. We conclude that Broca's area is specifically involved in rule-based knowledge, and here, in an improved ability to detect syntactic violations. The results cannot be explained by better tDCS-induced working memory performance during the acquisition phase. This is the first study that demonstrates that tDCS may facilitate acquisition of grammatical knowledge, a finding of potential interest for rehabilitation of aphasia.

  10. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  11. Effects of tissue conductivity and electrode area on internal electric fields in a numerical human model for ELF contact current exposures

    Science.gov (United States)

    Tarao, H.; Kuisti, H.; Korpinen, L.; Hayashi, N.; Isaka, K.

    2012-05-01

    Contact currents flow through the human body when a conducting object with different potential is touched. There are limited reports on numerical dosimetry for contact current exposure compared with electromagnetic field exposures. In this study, using an anatomical human adult male model, we performed numerical calculation of internal electric fields resulting from 60 Hz contact current flowing from the left hand to the left foot as a basis case. Next, we performed a variety of similar calculations with varying tissue conductivity and contact area, and compared the results with the basis case. We found that very low conductivity of skin and a small electrode size enhanced the internal fields in the muscle, subcutaneous fat and skin close to the contact region. The 99th percentile value of the fields in a particular tissue type did not reliably account for these fields near the electrode. In the arm and leg, the internal fields for the muscle anisotropy were identical to those in the isotropy case using a conductivity value longitudinal to the muscle fibre. Furthermore, the internal fields in the tissues abreast of the joints such as the wrist and the elbow, including low conductivity tissues, as well as the electrode contact region, exceeded the ICNIRP basic restriction for the general public with contact current as the reference level value.

  12. 城市住宅小区用电数据采集系统设计%DESIGNING ELECTRICITY DATA ACQUISITION SYSTEM FOR URBAN RESIDENTIAL AREA

    Institute of Scientific and Technical Information of China (English)

    闫丽华

    2012-01-01

    设计了一种针对城市居民小区电表用户的用电数据采集系统,采用了485总线、WIFI通信和Internet网络相结合的数据传输方式,既节约了成本,又保证了数据的可靠传输.数据集中器采用Windows CE操作系统,带有触摸屏,操作界面友好.整体方案具有一定的新颖性和独创性.%A data acquisition system was designed for metered electricity users in urban areas. The system made use of a 485 bus, WlFI communication and internet transmission, resulting in cost savings, and ensured reliability of data transmission. The data concentrator used a Windows CE operating system, with touch- screen, and friendly operation interface. The whole scheme demonstrated novelty and originality.

  13. Non-permanent GPS data for regional-scale kinematics: reliable deformation rate before the 6 April, 2009, earthquake in the L'Aquila area

    Directory of Open Access Journals (Sweden)

    Fabiana Loddo

    2010-05-01

    Full Text Available A GPS-based geodetic study at a regional scale requires the availability of a dense network that is characterized by 10 km to 30 km spacing, typically followed in a few continuous GPS stations (CGPSs and several non-permanent GPS stations (NPSs. As short observation times do not allow adequate noise modeling, NPS data need specific processing where the main differences between NPSs and CGPSs are taken into account: primarily time-series length and antenna repositioning error. The GPS data collected in the 1999-2007 time-span from non-permanent measurement campaigns in the central Apennine area (Italy that was recently hit by the Mw 6.3 L'Aquila earthquake (April 6, 2009 are here further analyzed to compute a reliable strain-rate field at a regional scale. Moreover, areas characterized by different kinematics are recognized, and a complete characterization of the regional-scale kinematics is attempted. These new data can be interpreted as indicators from the viewpoint of seismic risk assessment.

  14. Relationship Between Aerosol Number Size Distribution and Atmospheric Electric Potential Gradient in an Urban Area

    Science.gov (United States)

    Wright, Matthew; Matthews, James; Bacak, Asan; Silva, Hugo; Priestley, Michael; Percival, Carl; Shallcross, Dudley

    2016-04-01

    Small ions are created in the atmosphere by ground based radioactive decay and solar and cosmic radiation ionising the air. The ionosphere is maintained at a high potential relative to the Earth due to global thunderstorm activity, a current from the ionosphere transfers charge back to the ground through the weakly ionised atmosphere. A potential gradient (PG) exists between the ionosphere and the ground that can be measured in fair weather using devices such as an electric field mill. PG is inversely-proportional to the conductivity of the air and therefore to the number of ions of a given electrical mobility; a reduction of air ions will cause an increase of PG. Aerosols in the atmosphere act as a sink of air ions with an attachment rate dependent on aerosol size distribution and ion mobility. These relationships have been used to infer high particulate, and hence pollution, levels in historic datasets of atmospheric PG. A measurement campaign was undertaken in Manchester, UK for three weeks in July and August where atmospheric PG was measured with an electric field mill (JCI131, JCI Chilworth) on a second floor balcony, aerosol size distribution measured with a scanning mobility particle sizer (SMPS, TSI3936), aerosol concentration measured with a condensation particle counter (CPC, Grimm 5.403) and local meteorological measurements taken on a rooftop measurement site ~200 m away. Field mill and CPC data were taken at 1 s intervals and SMPS data in 2.5 minute cycles. Data were excluded for one hour either side of rainfall as rainclouds and droplets can carry significant charge which would affect PG. A quantity relating to the attachment of ions to aerosol (Ion Sink) was derived from the effective attachment coefficient of the aerosols. Further measurements with the field mill and CPC were taken at the same location in November 2015 when bonfire events would be expected to increase aerosol concentrations. During the summer measurements, particle number count (PNC

  15. Multi area and multistage expansion-planning of electricity supply with sustainable energy development criteria: a multi objective model

    Energy Technology Data Exchange (ETDEWEB)

    Unsihuay-Vila, Clodomiro; Marangon-Lima, J.W.; Souza, A.C Zambroni de [Universidade Federal de Itajuba (UNIFEI), MG (Brazil)], emails: clodomirounsihuayvila @gmail.com, marangon@unifei.edu.br, zambroni@unifei.edu.br; Perez-Arriaga, I.J. [Universidad Pontificia Comillas, Madrid (Spain)], email: ipa@mit.edu

    2010-07-01

    A novel multi objective, multi area and multistage model to long-term expansion-planning of integrated generation and transmission corridors incorporating sustainable energy developing is presented in this paper. The proposed MESEDES model is a multi-regional multi-objective and 'bottom-up' energy model which considers the electricity generation/transmission value-chain, i.e., power generation alternatives including renewable, nuclear and traditional thermal generation along with transmission corridors. The model decides the optimal location and timing of the electricity generation/transmission abroad the multistage planning horizon. The MESEDES model considers three objectives belonging to sustainable energy development criteria such as: a) the minimization of investments and operation costs of : power generation, transmission corridors, energy efficiency (demand side management (DSM) programs) considering CO2 capture technologies; b) minimization of Life Cycle Greenhouse Gas Emissions (LC GHG); c) maximization of the diversification of electricity generation mix. The proposed model consider aspects of the carbon abatement policy under the CDM - Clean Development Mechanism or European Union Greenhouse Gas Emission Trading Scheme. A case study is used to illustrate the proposed framework. (author)

  16. Energy Systems Test Area (ESTA) Electrical Power Systems Test Operations: User Test Planning Guide

    Science.gov (United States)

    Salinas, Michael J.

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Electrical Power Systems Test Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  17. Differentiated long term projections of the hourly electricity consumption in local areas. The case of Denmark West

    DEFF Research Database (Denmark)

    Møller Andersen, Frits; Larsen, Helge V.; Juul, Nina

    2014-01-01

    .000 and 100.000 customers. Data for the hourly electricity consumption at transformer stations shows that the profile of consumption differs considerably between local areas, and this is partly due to a different weight of categories of customers in the different areas. Categories of customers have quite...... distinct consumption profiles and contribute quite differently to the aggregated load profile. In forecasts, demand by categories of customers is expected to develop differently implying that both the level and the profile of consumption at each transformer stations are expected to change differently...... consumption by categories of customers and data for the hourly consumption at each transformer station for the years 2009–2011. Applying the model for load forecasts, a major conclusion is that different transformer stations will experience different changes both in the level - and in the hourly profile...

  18. Hybrid and electric low-noise cars cause an increase in traffic accidents involving vulnerable road users in urban areas.

    Science.gov (United States)

    Brand, Stephan; Petri, Maximilian; Haas, Philipp; Krettek, Christian; Haasper, Carl

    2013-01-01

    Due to resource scarcity, the number of low-noise and electric cars is expected to increase rapidly. The frequent use of these cars will lead to a significant reduction of traffic related noise and pollution. On the other hand, due to the adaption and conditioning of vulnerable road users the number of traffic accidents involving pedestrians and bicyclists is postulated to increase as well. Children, older people with reduced eyesight and the blind are especially reliant on a combination of acoustic and visual warning signals with approaching or accelerating vehicles. This is even more evident in urban areas where the engine sound is the dominating sound up to 30 kph (kilometres per hour). Above this, tyre-road interaction is the main cause of traffic noise. With the missing typical engine sound a new sound design is necessary to prevent traffic accidents in urban areas. Drivers should not be able to switch the sound generator off.

  19. The use of the electric vehicle in the metropolitan area of Mexico city; Uso de vehiculos electricos en el area metropolitana de la ciudad de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Robles, G. [Centro de Intrumentos, UNAM, Mexico, D. F. (Mexico); Sheinbaum, C. [Instituto de Ingenieria, UNAM, Mexico, D. F. (Mexico)

    1997-12-31

    A study is performed on the impact that the introduction of the electric vehicle (EV) would have in the environmental pollution of the metropolitan area of Mexico City (MAMC) for different penetration scenarios of this technology and the costs of the electric vehicle is analyzed and compared with its counterpart, the gasoline vehicle. The associated emissions of a fleet formed of EV and internal combustion engine vehicles (ICEV) were determined and the emissions reduction of the contaminants considered in the period 1995-2010 produced was analyzed. It was found that the introduction of EV could importantly reduce the carbon monoxide, methane and carbon dioxide and marginally the nitrogen oxides. It was determined that if the EV is massively produced its total cost for its entire useful life would be comparable to the cost of the ICEV. [Espanol] Se realiza un estudio sobre el impacto que tendria la introduccion de vehiculos electricos (VE) en la contaminacion ambiental del area metropolitana de la ciudad de Mexico (AMCM) para diferentes escenarios de penetracion de esta tecnologia y se analiza el costo de los vehiculos electricos en comparacion con su contraparte de gasolina. Se determinaron las emisiones asociadas a una flota compuesta de VE y vehiculos con motor de combustion interna (VMCI) y se analizo la reduccion que producia en las emisiones de los diferentes contaminantes considerados en el periodo 1995-2010. Se encontro que la introduccion de VE podria reducir de manera importante las emisiones de monoxido de carbono, metano y dioxido de carbono y marginalmente las de oxido de nitrogeno. Se determino que si los VE son producidos masivamente su costo total para toda su vida util seria comparable al correspondiente al de los VMCI.

  20. The Development, Validation, and Application of a Two-Tier Diagnostic Instrument to Detect Misconceptions in the Areas of Force, Heat, Light and Electricity

    Science.gov (United States)

    Franklin, Bobby Jo.

    1992-01-01

    The purpose of this study was to investigate the concepts prevalent among students in specific physical science related classes and to identify what classroom teachers would do when confronted with this knowledge. A 40 item instrument, Misconception Identification in Science Questionnaire (MISQ), was developed to identify certain concepts in the areas of force, heat, light, and electricity and administered to 509 students. Interviews were conducted with a stratified sampling of 27 students to validate the instrument. Six teachers were observed and interviewed to determine teacher opinion relative to test usefulness, diagnostic testing in general and other instructional factors. Quantitative and qualitative means were utilized to determine test reliability, validity, and usefulness. Item analysis was performed to determine item discrimination ability, as well as test reliability. Students were interviewed using the MISQ items and their oral responses were compared to their answers given on the pen-and-paper test. Confidence and sensibleness ratings were determined for each MISQ item utilizing responses given on the written test. The MISQ was analyzed and determined to have the ability to discriminate among various ability groups and possesses both validity and reliability. Female elementary science methods and physics students performed no better than the male physical science students on the MISQ. In general male students scored higher than their female peers and viewed their responses as more sensible and with more confidence. As age decreased among the students tested with the MISQ the confidence and sensibleness rating tended to decrease. Analysis of teacher interviews revealed three uses of the MISQ instrument in this study. The first of these was in the form of a general informative nature. The second utilized selected items as integral parts of the instructional process. The third used student responses as part of a grouping strategy. Further analysis reveals

  1. Development of electrical-erosion instrument for direct write micro-patterning on large area conductive thin films.

    Science.gov (United States)

    Álvarez, Ángel Luis; Coya, Carmen; García-Vélez, Miguel

    2015-08-01

    We have developed a complete instrument to perform direct, dry, and cost-effective lithography on conductive materials, based on localized electrical discharges, which avoids using masks or chemicals typical of conventional photolithography. The technique is considered fully compatible with substrate transport based systems, like roll-to-roll technology. The prototype is based on two piezo nano-steppers coupled to three linear micro-stages to cover a large scale operation from micrometers to centimeters. The operation mode consists of a spring probe biased at low DC voltage with respect to a grounded conductive layer. The tip slides on the target layer keeping contact with the material in room conditions, allowing continuous electric monitoring of the process, and also real-time tilt correction via software. The sliding tip leaves an insulating path (limited by the tip diameter) along the material, enabling to draw electrically insulated tracks and pads. The physical principle of operation is based in the natural self-limitation of the discharge due to material removal or insulation. The so produced electrical discharges are very fast, in the range of μs, so features may be performed at speeds of few cm/s, enabling scalability to large areas. The instrument has been tested on different conducting materials as gold, indium tin oxide, and aluminum, allowing the fabrication of alphanumeric displays based on passive matrix of organic light emitting diodes without the use of masks or photoresists. We have verified that the highest potential is achieved on graphene, where no waste material is detected, producing excellent well defined edges. This allows manufacturing graphene micro-ribbons with a high aspect ratio up to 1200:1.

  2. Development of electrical-erosion instrument for direct write micro-patterning on large area conductive thin films

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez, Ángel Luis; Coya, Carmen; García-Vélez, Miguel [Departamento Teoría de la Señal y Comunicaciones, Sistemas Telemáticos y Computación, Escuela Técnica Superior de Ingeniería de Telecomunicación, Universidad Rey Juan Carlos, Fuenlabrada, Madrid 28943 (Spain)

    2015-08-15

    We have developed a complete instrument to perform direct, dry, and cost-effective lithography on conductive materials, based on localized electrical discharges, which avoids using masks or chemicals typical of conventional photolithography. The technique is considered fully compatible with substrate transport based systems, like roll-to-roll technology. The prototype is based on two piezo nano-steppers coupled to three linear micro-stages to cover a large scale operation from micrometers to centimeters. The operation mode consists of a spring probe biased at low DC voltage with respect to a grounded conductive layer. The tip slides on the target layer keeping contact with the material in room conditions, allowing continuous electric monitoring of the process, and also real-time tilt correction via software. The sliding tip leaves an insulating path (limited by the tip diameter) along the material, enabling to draw electrically insulated tracks and pads. The physical principle of operation is based in the natural self-limitation of the discharge due to material removal or insulation. The so produced electrical discharges are very fast, in the range of μs, so features may be performed at speeds of few cm/s, enabling scalability to large areas. The instrument has been tested on different conducting materials as gold, indium tin oxide, and aluminum, allowing the fabrication of alphanumeric displays based on passive matrix of organic light emitting diodes without the use of masks or photoresists. We have verified that the highest potential is achieved on graphene, where no waste material is detected, producing excellent well defined edges. This allows manufacturing graphene micro-ribbons with a high aspect ratio up to 1200:1.

  3. Application of electrical resistivity method for groundwater exploration at the Moghra area, Western Desert, Egypt

    Directory of Open Access Journals (Sweden)

    M.I.I. Mohamaden

    2016-09-01

    Structurally, the study area is influenced by three faults two of them are geological/geoelectrical faults forming a graben structure at the central part; the third fault is a geoelectrical fault and is located to the west of the graben structure forming a horest structure.

  4. [Horizontal and vertical distribution of polybrominated diphenyl ethers (PBDEs) in river sediment from a typical electrical equipment industrial area].

    Science.gov (United States)

    Qiu, Meng-De; Deng, Dai-Yong; Yu, Le-Huan; Sun, Guo-Ping; Mai, Bi-Xian; Xu, Mei-Ying

    2012-02-01

    Polybrominated diphenyl ethers (PBDEs) were determined in sediment collected from a river in a typical electrical equipment industrial area, Ronggui, Foshan. Eight samples were collected from river sediment. The results indicated that PBDEs were presented in all samples. Spatial trends showed that the concentrations of PBDEs in all sediment samples were ranged from 62 ng x g(-1) to 349 ng x g(-1), with an average of 178 ng x g(-1). The predominant congener was BDE-209 (90% - 99%), which ranged from 56-337 ng x g(-1), with an average of 171 ng x g(-1). Some of congeners such as BDE-196, 197 and 203 may be were the degradation product of BDE-209. Vertically, the concentrations of PBDEs were increased with the depth, whereas the concentrations were 147 ng x g(-1) in layer 0-10 cm and 260 ng x g(-1) in layer 30-40 cm, respectively. Distribution profile of PBDEs in vertical direction was similar in different depths. The commercial deca-BDE (94%), which contained BDE-209, 208, 207 and 206, was the dominate pollutant with minor contributions from penta-and octa-BDEs. The results suggested that this area was polluted by PBDEs and BDE-209 was the most dominate congener, which is related with the manufacturing activities for electrical equipment.

  5. Reliability and safety engineering

    CERN Document Server

    Verma, Ajit Kumar; Karanki, Durga Rao

    2016-01-01

    Reliability and safety are core issues that must be addressed throughout the life cycle of engineering systems. Reliability and Safety Engineering presents an overview of the basic concepts, together with simple and practical illustrations. The authors present reliability terminology in various engineering fields, viz.,electronics engineering, software engineering, mechanical engineering, structural engineering and power systems engineering. The book describes the latest applications in the area of probabilistic safety assessment, such as technical specification optimization, risk monitoring and risk informed in-service inspection. Reliability and safety studies must, inevitably, deal with uncertainty, so the book includes uncertainty propagation methods: Monte Carlo simulation, fuzzy arithmetic, Dempster-Shafer theory and probability bounds. Reliability and Safety Engineering also highlights advances in system reliability and safety assessment including dynamic system modeling and uncertainty management. Cas...

  6. Income distribution impacts of changes in Western Area Power Administration electricity prices. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rose, A.; Frias, O. [Pennsylvania State Univ., University Park, PA (United States). Dept. of Mineral Economics

    1993-06-01

    The purpose of this report is to present the methodology and results of an analysis of income distribution impacts associated with changes in the Western Area Power Administration (WAPA) marketing program. The focus will be on the distribution of personal income across eleven brackets in each of nine sub-regions of the WAPA market area. Moreover, these results will be translated into an assessment of the number of people who stand to gain or lose as a result of the policies and the size of these income changes. Most economic impact analyses are performed at an aggregate level. The results are typically presented in terms of net benefits, or a listing of changes in employment, output, income, or prices. What is neglected is the distribution of impacts across the affected population. These distributional impacts are important for several reasons. First, there is the normative judgmental issue of distributional justice, or equity. This addresses concerns about income disparities in general, or whether the poor, or any other group, are shouldering a disproportionate share of any burden or are failing to share significantly in any gain.

  7. Changing the spatial location of electricity generation to increase water availability in areas with drought: a feasibility study and quantification of air quality impacts in Texas

    Science.gov (United States)

    Pacsi, Adam P.; Alhajeri, Nawaf S.; Webster, Mort D.; Webber, Michael E.; Allen, David T.

    2013-09-01

    The feasibility, cost, and air quality impacts of using electrical grids to shift water use from drought-stricken regions to areas with more water availability were examined. Power plant cooling represents a large portion of freshwater withdrawals in the United States, and shifting where electricity generation occurs can allow the grid to act as a virtual water pipeline, increasing water availability in regions with drought by reducing water consumption and withdrawals for power generation. During a 2006 drought, shifting electricity generation out of the most impacted areas of South Texas (∼10% of base case generation) to other parts of the grid would have been feasible using transmission and power generation available at the time, and some areas would experience changes in air quality. Although expensive, drought-based electricity dispatch is a potential parallel strategy that can be faster to implement than other infrastructure changes, such as air cooling or water pipelines.

  8. Towards a functional topography of sensory gating areas: invasive P50 recording and electrical stimulation mapping in epilepsy surgery candidates.

    Science.gov (United States)

    Kurthen, Martin; Trautner, Peter; Rosburg, Timm; Grunwald, Thomas; Dietl, Thomas; Kühn, Kai-Uwe; Schaller, Carlo; Elger, Christian E; Urbach, Horst; Elisevich, Kost; Boutros, Nash N

    2007-07-15

    The filtering of sensory information, also referred to as "sensory gating", is impaired in various neuropsychiatric diseases. In the auditory domain, sensory gating is investigated mainly as a response decrease of the auditory evoked potential component P50 from one click to the second in a double-click paradigm. In order to relate deficient sensory gating to anatomy, it is essential to identify the cortical structures involved in the generation of P50. However, the exact cerebral topography of P50 gating remains largely unknown. In a group of 17 patients with drug-resistant focal epilepsy, P50 was recorded invasively via subdural electrodes, and the topography of functionally indispensable ("eloquent") cortices was obtained by electrical stimulation mapping. These eloquent areas were involved in language, motor, and sensory functions. P50 could be identified in 13 patients in either temporal (n=8) or midfrontal sites (n=5). There were six occurrences (in five patients) of overlap of sites with maximal P50 responses and eloquent areas. Those were auditory (n=1), supplementary sensorimotor (n=3), primary motor (n=1), and supplementary negative motor (n=1). Results suggest that the early stage of sensory gating already involves a top-down modulation of sensory input by frontal areas.

  9. Use of electrical tomography methods to determinate the extension and main migration routes of uncontrolled landfill leachates in fractured areas

    Energy Technology Data Exchange (ETDEWEB)

    Casado, Ismael, E-mail: iscaferr@gmail.com [Department of Petrology, Geochemistry and Geological Prospectio, Universitat de Barcelona, Martí i Franquès s/n, 08030 Barcelona (Spain); Department of Geology and Environmental Earth Science, Miami University, 501 East High Street, 45056 Oxford, OH (United States); Mahjoub, Himi [Department of Petrology, Geochemistry and Geological Prospectio, Universitat de Barcelona, Martí i Franquès s/n, 08030 Barcelona (Spain); Ecole Nationale des Sciences Appliquées d' Al Hoceima (ENSAH), University Mohammed Premier, Ajdir, Al Hoceima (Morocco); Lovera, Raul [Department of Petrology, Geochemistry and Geological Prospectio, Universitat de Barcelona, Martí i Franquès s/n, 08030 Barcelona (Spain); Fernández, Jesús, E-mail: jfernandezc@aragon.es [Department of Agriculture, Ranching and Environment, Diputación General de Aragon (DGA), Plaza de San Pedro Nolasco, 7, 50071 Zaragoza (Spain); Casas, Albert [Department of Petrology, Geochemistry and Geological Prospectio, Universitat de Barcelona, Martí i Franquès s/n, 08030 Barcelona (Spain)

    2015-02-15

    This study focuses on the uses of the electrical tomography and its relationship with hydrochemical data in order to characterize contaminated groundwater flows in fractured aquifers. The studied area is contaminated with different hazardous substances like lyndanes, organochlorinated compounds and benzenes coming from the old non-controlled Sardas landfill. The enormous volumes of wastes filling the landfill have generated a convoluted mixture of leachates. Due to the lack of a landfill liner, the leachates have migrated through the fractured Eocene marls towards the Gallego River. The striking correlation between high concentrations of polluted groundwater and low electrical resistivity of the subsurface (< 8 Ω·m) allows defining the principal contaminant migration route thanks to the distribution of these conductive anomalies. This mapping verifies that there is intense tectonical–structural control of the leachate migration, because the deep migration presents the same direction as the geological axis fold. - Highlights: • The outcrop topographic reconstruction is done using cores and aerial photographs. • Hydrochemical and geophysical data allow defining two leachate migration paths. • Conductive anomalies in ERT are linked to high contaminant concentration. • The distribution of conductive anomalies defines the fractured basement migration. • The plume direction reflects important tectonic control in the migration process.

  10. Synergistic Use of Nighttime Satellite Data, Electric Utility Infrastructure, and Ambient Population to Improve Power Outage Detections in Urban Areas

    Directory of Open Access Journals (Sweden)

    Tony A. Cole

    2017-03-01

    Full Text Available Natural and anthropogenic hazards are frequently responsible for disaster events, leading to damaged physical infrastructure, which can result in loss of electrical power for affected locations. Remotely-sensed, nighttime satellite imagery from the Suomi National Polar-orbiting Partnership (Suomi-NPP Visible Infrared Imaging Radiometer Suite (VIIRS Day/Night Band (DNB can monitor power outages in disaster-affected areas through the identification of missing city lights. When combined with locally-relevant geospatial information, these observations can be used to estimate power outages, defined as geographic locations requiring manual intervention to restore power. In this study, we produced a power outage product based on Suomi-NPP VIIRS DNB observations to estimate power outages following Hurricane Sandy in 2012. This product, combined with known power outage data and ambient population estimates, was then used to predict power outages in a layered, feedforward neural network model. We believe this is the first attempt to synergistically combine such data sources to quantitatively estimate power outages. The VIIRS DNB power outage product was able to identify initial loss of light following Hurricane Sandy, as well as the gradual restoration of electrical power. The neural network model predicted power outages with reasonable spatial accuracy, achieving Pearson coefficients (r between 0.48 and 0.58 across all folds. Our results show promise for producing a continental United States (CONUS- or global-scale power outage monitoring network using satellite imagery and locally-relevant geospatial data.

  11. Electrical and Optical Properties of a High-Voltage Large Area Blue Light-Emitting Diode

    Science.gov (United States)

    Wang; Wei; Cai; Yong; Huang; Wei; Li; Hai-ou; Zhang; Bao-shun

    2013-08-01

    In this paper, we report a single-chip large area (5×5 mm2) InGaN/GaN blue LED with the optical output power of 4.3 W. This device consists of 24-stages small LED-cells that are connected in series. Driven at 500 mA, the forward voltage is measured to be 87.2 V with a reverse current of 2.63×10-9 A at -120 V. The comparison of two different cooling schemes, i.e., with/without fan cooling, was made; the results suggest that the thermal convection between the heat sink and air is more critical. A simple white LED package was also tried by covering silicone gel mixed with yttrium aluminum garnet (YAG) phosphor. The luminous flux and the correlated color temperature (CCT) were measured to be 1090 lm and 5082 K, when the device was driven at 500 mA. This report also demonstrated the feasibility of the application for camera flash.

  12. Photovoltaic module reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Mrig, L. (ed.)

    1990-01-01

    The paper and presentations compiled in this volume form the Proceedings of the fourth in a series of Workshops sponsored by Solar Energy Research Institute (SERI/DOE) under the general theme of photovoltaic module reliability during the period 1986--1990. The reliability Photo Voltaic (PV) modules/systems is exceedingly important along with the initial cost and efficiency of modules if the PV technology has to make a major impact in the power generation market, and for it to compete with the conventional electricity producing technologies. The reliability of photovoltaic modules has progressed significantly in the last few years as evidenced by warranties available on commercial modules of as long as 12 years. However, there is still need for substantial research and testing required to improve module field reliability to levels of 30 years or more. Several small groups of researchers are involved in this research, development, and monitoring activity around the world. In the US, PV manufacturers, DOE laboratories, electric utilities and others are engaged in the photovoltaic reliability research and testing. This group of researchers and others interested in this field were brought together under SERI/DOE sponsorship to exchange the technical knowledge and field experience as related to current information in this important field. The papers presented here reflect this effort.

  13. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  14. 76 FR 71011 - Reliability Technical Conference Agenda

    Science.gov (United States)

    2011-11-16

    ..., President and CEO, Consolidated Edison Inc., on behalf of Consolidated Edison and the Edison Electric..., North American Electric Reliability Corporation Thomas J. Galloway, President and Chief Executive... Monroe, Executive Vice President and Chief Operating Officer, Southwest Power Pool (SPP) Thomas...

  15. Assessing the reliability of microscopy and rapid diagnostic tests in malaria diagnosis in areas with varying parasite density among older children and adult patients in Nigeria

    Directory of Open Access Journals (Sweden)

    E E Ayogu

    2016-01-01

    Full Text Available Background: Current malaria control strategies are based on early diagnosis and appropriate treatment of malaria cases. The study aimed at comparing the performance of blood film microscopy and rapid diagnostic test (RDT in Plasmodium falciparum detection in patients ≥6 years of age. Materials and Methods: A total of 154 consecutive pyretic patients aged 6-62 years were enrolled, sampled, and tested for malaria using RDT (first response and microscopy by Giemsa staining. Genomic DNA was extracted after saponin hemolysis and nested polymerase chain reaction (PCR was used to detect Plasmodium falciparum. The endpoints were sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV. Results: Of the 154 patients, 80 (51.9% had fever of ≥37.5°C. 106 (68.8% were positive by First response® , 132 (85.7% by microscopy, and 121 (78.6% by PCR. The sensitivity, specificity, PPV, and NPV of first response compared to microscopic method were 82.2%, 100.0%, 100.0%, and 34.3%, respectively, while it was 75.4%, 75.0%, 95.3%, and 31.2%, respectively, when compared to PCR. The sensitivity, specificity, PPV, and NPV of the microscopic method compared to PCR were 92.3%, 50.0%, 90.91%, and 54.5%, respectively. There was a significant difference in the performance of RDT and film microscopy methods (P ≤ 0.05. Conclusion: Microscopy performed better and is more reliable than first response (RDT in areas with low parasite density among patients ≥6 years of age. Rapid diagnostic tests could be useful in aareas with high parasite density as an alternative to smear microscopy

  16. InSAR techniques for reliable deformation estimation in volcanic areas and a first glance of Tandem-DEM accuracy - test site El Hierro Island

    Science.gov (United States)

    Cong, X.; Eineder, M.; Fritz, T.

    2013-12-01

    The accuracy and availability of deformation measurements using InSAR techniques is limited due to decorrelation effects, atmospheric disturbances and the SAR side-looking geometry (layover and shadowing). In this talk, we present our recent research and achievements on advanced InSAR techniques in order to retrieve reliable deformation signals from active volcanoes using high resolution TerraSAR-X (TSX) images. Another highlight of this talk is the evaluation of an experimental TanDEM-X (TDX) RawDEM with a resolution of approximately 6 m in order to compensate the topographic phase. A volcanic test site which is currently highly active -El Hierro- has been selected to demonstrate the developed techniques: 1) PSI processing in volcanic areas using high resolution TSX images; 2) Mitigation of atmospheric delay distortions; 3) Fusion of multi-geometrical PSI clouds. In order to measure the deformation from 2011 to 2013 at El Hierro [1], two stacks of stripmap TSX Mission data have been acquired, one in ascending orbit and one in descending. Each stack has more than 25 scenes. More than 1.5 million PSs have been detected (SCR>3.0 dB). The stratified atmospheric delay for each acquisition has been integrated for the PSI reference network and, afterwards, interpolated and compensated for all PSs. A linear deformation model has been assumed for PSI processing. For the descending orbit stack, a relative deformation from -21.7 to 131.8 mm/y from Sep. 2011 to Jan. 2013 with respect to a reference point located on the northeast coast has been measured. On the one hand, the spatial variation of the deformation has a good agreement with the seismicity distribution [1]. On the other hand, the deformation magnitude agrees with in-situ GPS measurements [2]. In ascending orbit, the linear deformation rate varies from -22.8 to 90.9 mm/y. This different range of value is due to a scene acquired on Feb. 2010, which has been included in order to obtain the pre-seismic deformation

  17. Optimal design of an atmospheric water generator (AWG) based on thermo-electric cooler (TEC) for drought in rural area

    Science.gov (United States)

    Suryaningsih, Sri; Nurhilal, Otong

    2016-02-01

    Drinking water availability is a major issue in some rural area in Indonesia during the summer season due to lack of rainfall, which peoples in this area have to fetch the water a few kilometers away from home. The Atmospheric Water Generator (AWG) is one of the alternative solution for fresh water recovery from atmosphere which is directly condensed the moisture content of water vapor from the air. This paper presents the method to develop a prototype of an AWG based on Thermo-electric cooler (TEC) that used 12 Volt DC, hence its suitability for using renewable energy resource. Computational Fluid Dynamics (CFD) is utilized to optimize the design process in the flow region only, it's not suitable for recent CFD software to use in Multi physics, because inaccuracy, cost and time saving. Some parameters such as temperature, moisture content, air flow, pressure, form of air flow channel and the water productivity per unit input of energy are to be considered. The result is presented as an experimental prototype of an AWG based on TEC and compared with other conventional commercial products.

  18. [Pollution characteristics and ecological risk of polybrominated diphenyl ethers (PBDEs) in river sediments from an electrical equipment dismantling area].

    Science.gov (United States)

    Chen, Xuan-Yu; Xue, Nan-Dong; Zhang, Shi-Lei; Li, Fa-Sheng; Gong, Dao-Xin; Liu, Bo; Meng, Lei

    2014-10-01

    Polybrominated diphenyl ethers (PBDEs) were determined in sediments collected from a river which through an electrical equipment dismantling area. The results showed that concentrations of PBDEs ranged from 101 to 20,400 ng · g(-1) with an average of 3,700 ng · g(-1), and BDE209 was the most dominant homologue accounted for more than 94% of all detected homologues. The concentration of PBDEs was higher in the middle of river than that in upstream and downstream and the average concentration in downstream was higher than the upstream, with a peak of concentration in the area near by dismantling industrial park. PBDEs pollution in this region is relatively serious compared with other regions. It was estimated that 0.39 t PBDEs (including 0.36 t BDE209) was discharged into the river as a result of dismantling industrial activities in last 40 years. A preliminary ecological risk assessment for PBDEs in sediments was conducted by hazard quotient method, the results showed that the OctaBDEs and DecaBDEs were in a low ecological risk, while the PentaBDEs was in a particularly high risk and could cause great harm to the environment.

  19. Reliability of power connections

    Institute of Scientific and Technical Information of China (English)

    BRAUNOVIC Milenko

    2007-01-01

    Despite the use of various preventive maintenance measures, there are still a number of problem areas that can adversely affect system reliability. Also, economical constraints have pushed the designs of power connections closer to the limits allowed by the existing standards. The major parameters influencing the reliability and life of Al-Al and Al-Cu connections are identified. The effectiveness of various palliative measures is determined and the misconceptions about their effectiveness are dealt in detail.

  20. ELECTRIC INFRASTRUCTURE TECHNOLOGY, TRAINING, AND ASSESSMENT PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    TREMEL, CHARLES L

    2007-06-28

    The objective of this Electric Infrastructure Technology, Training and Assessment Program was to enhance the reliability of electricity delivery through engineering integration of real-time technologies for wide-area applications enabling timely monitoring and management of grid operations. The technologies developed, integrated, tested and demonstrated will be incorporated into grid operations to assist in the implementation of performance-based protection/preventive measures into the existing electric utility infrastructure. This proactive approach will provide benefits of reduced cost and improved reliability over the typical schedule-based and as needed maintenance programs currently performed by utilities. Historically, utilities have relied on maintenance and inspection programs to diagnose equipment failures and have used the limited circuit isolation devices, such as distribution main circuit breakers to identify abnormal system performance. With respect to reliable problem identification, customer calls to utility service centers are often the sole means for utilities to identify problem occurrences and determine restoration methodologies. Furthermore, monitoring and control functions of equipment and circuits are lacking; thus preventing timely detection and response to customer outages. Finally, the two-way flow of real-time system information is deficient, depriving decision makers of key information required to effectively manage and control current electric grid demands to provide reliable customer service in abnormal situations. This Program focused on advancing technologies and the engineering integration required to incorporate them into the electric grid operations to enhance electrical system reliability and reduce utility operating costs.

  1. High Concentration of Heat Pumps in Suburban Areas and Reduction of Their Impact on the Electricity Network

    OpenAIRE

    Pruissen, O.P. van; Kamphuis, I.G.

    2011-01-01

    One of the challenges of the near future for a more renewable Dutch electricity infrastructure is the embedding of high concentrations of heat pumps in currently built domestic residences. In the Dutch situation demand of electricity occurs simultaneously with demand of heat, high electricity peak loads in the low voltage network are expected. This study focuses on domestic residences with high peak loads at substations when heating is provided merely by heat pumps with additional electric re...

  2. The Potential Application of Gasification for Biomass Power Generation in Isolated Area from National Electricity Company in Indonesia

    Directory of Open Access Journals (Sweden)

    Kiman Siregar

    2016-01-01

    Full Text Available Indonesia has renewable energy source very large, as biomass. Installed capacity power plants of Indonesia now 53,585 MW, where the potential energy biomass is the largest of renewable sources of energy that owned by Indonesia. The machine of gasification is designed to produce combustible gas (CO, H2, CH4. These combustible gas are produced to replace fossil fuel as engine fuel to generate electricity. However, the properties and characteristics of these combustible gas should meet the characteristic of the engine as every engine has its own specific characteristic. In this research, Biomass Power Generation (BPG which work more properly with CO was used. High level of tar contained in produced combustible gas contaminates the engine filter rapidly. Therefore, the machine cannot be operated at a longer time. The objective of this research was to study the potential application of downdraft gasification machine with high content of CO and low production of tar. Downdraft gasification machine which designed in this research had installed capacity as much as 50 kW with reactor diameter and height were 900 mm and 1000 mm, respectively. The testing result showed that power generated from this machine was 40 kW, efficiency 80 % and can be operated for 6 hours. The optimum combustible gas produced by this machine occurred at CO, H2 and CH4 content were 21.75 %, 13.12 % and 1.12 %, respectively. Besides of using active carbon, tar removal was carried out using dust trap system (wet scrubber. The potential reduction of value of greenhouse gases emission is about 37 until 67 %. Based on an analysis calculation of financial , a test performance of gasification, and analysis of environmental impact, the use of system gasification can be used on a system a power plant in the isolated area from national electricity company in Indonesia.

  3. High Concentration of Heat Pumps in Suburban Areas and Reduction of Their Impact on the Electricity Network

    NARCIS (Netherlands)

    Pruissen, O.P. van; Kamphuis, I.G.

    2011-01-01

    One of the challenges of the near future for a more renewable Dutch electricity infrastructure is the embedding of high concentrations of heat pumps in currently built domestic residences. In the Dutch situation demand of electricity occurs simultaneously with demand of heat, high electricity peak l

  4. Electric Service Areas, Lyon County Electric Service Provider Areas. We are not in the notification loop if this changes. Data may not be current., Published in 2011, 1:4800 (1in=400ft) scale, City of Emporia/Lyon County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Service Areas dataset, published at 1:4800 (1in=400ft) scale, was produced all or in part from Hardcopy Maps information as of 2011. It is described as...

  5. The key technology in the section algorithm of reliability evaluation for complex medium voltage electrical distribution network%复杂配网可靠性分块算法的关键技术

    Institute of Scientific and Technical Information of China (English)

    郭小磊

    2014-01-01

    The reliability of distribution network is an important factor of many power supply business. A fast section algorithm of reliability evaluation for complex medium voltage electrical distribution networks is analyzed and improved. The partition method of the fault types is given based on the failure mode and effect analysis, and the principles of the construction of adjacency matrix in the network division are adopted. Besides, the methods of calculation in the reliability parameter equivalent and the construction of simplified model of distribution network are also put forward.%配电网可靠性是各省市供电企业的重点考核指标。对复杂中压配电网的可靠性评估分块算法进行了技术分析和完善,在故障后果模式分析法的基础上,给出了具体的故障类型划分思路,提出了利用邻接矩阵算法进行网络分块的指导原则,并对可靠性参数等效计算和简化配网模型的形成进行了简要分析,给出了具体简化配网模型的形成方法。

  6. A reliability diagnosis method for electric power optical fiber transmission network based on PMC model%基于PMC模型的电力光纤传输网可靠性诊断方法

    Institute of Scientific and Technical Information of China (English)

    李莉; 高丽媛; 赵旷怡; 吴润泽

    2016-01-01

    电力通信系统可靠性是指电力通信系统在实际连续运行过程中,完成电力系统正常通信需求的能力,是现代电力系统可靠性研究的一个重要部分.保证电力通信网的可靠性是电力系统安全体系中的一个十分重要的方面,本文对现代电力通信网的可靠性诊断问题进行了专门的研究.文章采用PMC互测方法对电力通信网的网络节点进行故障诊断,通过对某地区SDH光网络中故障节点具体诊断,证明该方法能够迅速准确地找出故障节点,从而保证了电力系统的连续运行.%The reliability of electric power communication system refers to the ability of power system to complete the communication needs in the process of actual operation . The reliability of the electric power communication network problem is one of the important aspects of modern power system security system which is specifically studied in this paper . The paper diagnoses the fault nodes in the electric power communication network based on PMC model. The specific diagnosis of a SDH optical network failed nodes proving that the method can identify the failed nodes quickly and accurately, thus ensuring the continuous operation of the power system .

  7. 塔设备裙座支撑区可靠性分析%Reliability Analysis of the Tower Skirt Support Area

    Institute of Scientific and Technical Information of China (English)

    许艳玲; 张保; 彭桐睿

    2012-01-01

    The paper Through the finite element analysis software ANSYS, analyzed the tower skirt support area's reliability with the finite element method, and according to the calculation results, evaluated the tower equipment skirt support area's reliability and its parameters sensitivity, and provided a useful reference for the mechanical strength reliability design.%采用有限元分析软件ANSYS,对塔设备裙座支撑区的可靠性进行有限元分析,并基于计算结果对该塔设备裙座支撑区的可靠性及参数敏感性进行分析和评价,为机械设备强度的可靠性设计提供有益的参考。

  8. Electrical Resistivity Correlation to Vadose Zone Sediment and Pore-Water Composition for the BC Cribs and Trenches Area

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R. Jeffrey; Ward, Anderson L.; Um, Wooyong; Bjornstad, Bruce N.; Rucker, Dale F.; Lanigan, David C.; Benecke, Mark W.

    2009-06-01

    This technical report documents the results of geochemical and soil resistivity characterization of sediment obtained from four boreholes drilled in the BC Cribs and Trench area. Vadose zone sediment samples were obtained at a frequency of about every 2.5 ft from approximately 5 ft bgs to borehole total depth. In total, 505 grab samples and 39 six-inch long cores were obtained for characterization. The pore-water chemical composition data, laboratory-scale soil resistivity and other ancillary physical and hydrologic measurements and analyses described in this report are designed to provide a crucial link between direct measurements on sediments and the surface-based electrical-resistivity information obtained via field surveys. A second goal of the sediment characterization was to measure the total and water-leachable concentrations of key contaminants of concern as a function of depth and distance from the footprints of inactive disposal facilities. The total and water-leachable concentrations of key contaminants will be used to update contaminant distribution conceptual models and to provide more data for improving base-line risk predictions and remedial alternative selections. The ERC “ground truthing” exercise for the individual boreholes showed mixed results. In general, the high concentrations of dissolved salts in the pore waters of sediments from C5923, C5924 and C4191 produced a low resistivity “target” in the processed resistivity field surveys, and variability could be seen in the resistivity data that could relate to the variability in pore- water concentrations but the correlations (regression R2 were mediocre ranging from 0.2 to 0.7 at best; where perfect correlation is 1.0). The field-based geophysical data also seemed to suffer from a sort of vertigo, where looking down from the ground surface, the target (e.g., maximum pore-water salt concentration) depth was difficult to resolve. The best correlations between the field electrical

  9. Reliability assessment of wave Energy devices

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kramer, Morten; Kofoed, Jens Peter

    2014-01-01

    Energy from waves may play a key role in sustainable electricity production in the future. Optimal reliability levels for components used for Wave Energy Devices (WEDs) need to be defined to be able to decrease their cost of electricity. Optimal reliability levels can be found using probabilistic...

  10. 75 FR 81157 - Version One Regional Reliability Standard for Transmission Operations

    Science.gov (United States)

    2010-12-27

    ... Henery (Technical Information), Office of Electric Reliability, Division of Policy Analysis and...- 8636. Danny Johnson (Technical Information), Office of Electric Reliability, Division of Reliability... by a physical difference in the Bulk-Power System. When the ERO reviews a regional...

  11. Reliability Assessment Of Wind Turbines

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2014-01-01

    Reduction of cost of energy for wind turbines are very important in order to make wind energy competitive compared to other energy sources. Therefore the turbine components should be designed to have sufficient reliability but also not be too costly (and safe). This paper presents models...... for uncertainty modeling and reliability assessment of especially the structural components such as tower, blades, substructure and foundation. But since the function of a wind turbine is highly dependent on many electrical and mechanical components as well as a control system also reliability aspects...... of these components are discussed and it is described how there reliability influences the reliability of the structural components. Two illustrative examples are presented considering uncertainty modeling, reliability assessment and calibration of partial safety factors for structural wind turbine components exposed...

  12. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  13. 46 CFR 169.619 - Reliability.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Reliability. 169.619 Section 169.619 Shipping COAST... Electrical Steering Systems § 169.619 Reliability. (a) Except where the OCMI judges it impracticable, the... be below that necessary for the safe navigation of the vessel. (c) The strength and reliability...

  14. On reliability optimization for power generation systems

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The reliability level of a power generation system is an important problem which is concerned by both electricity producers and electricity consumers. Why? It is known that the high reliability level may result in additional utility cost, and the low reliability level may result in additional consumer's cost, so the optimum reliability level should be determined such that the total cost can reach its minimum. Four optimization models for power generation system reliability are constructed, and the proven efficient solutions for these models are also given.

  15. Reliability of electricity supply. Critical analysis of the dena short analysis of power plant and grid planning in Germany through 2020; Versorgungssicherheit in der Elektrizitaetsversorgung. Kritische Wuerdigung der dena-Kurzanalyse zur Kraftwerks- und Netzplanung in Deutschland bis 2020

    Energy Technology Data Exchange (ETDEWEB)

    Borchert, Joerg; Jungbluth, Christian; Peek, Markus; Ritzau, Michael [Buero fuer Energiewirtschaft und technische Planungen GmbH (BET), Aachen (Germany)

    2009-09-15

    The publication shows that the dena study has serious shortcomings, both in its methodology and in its assumption of energy industry boundary conditions. The best options for development of the power plant park in consideration of climate protection, low price, reliability of supply and high availability cannot be derived using simple time-dependent and static methods. Effective analyses must comprise a simultaneous analysis of power and energy balances, in consideration of the need for power reserves in a dynamic context. Further, market mechanisms must be considered that take account of the neighbouring European markets and the effective mechanisms of deregulated electricity markets. Not least, the political boundary conditions must be considered, e.g. greenhouse gas emissions and financial incentives for renewable energy sources. Even though such analyses are highly complex, they are indispensable if erroneous conclusions are to be prevented.

  16. Mass and elemental distributions of atmospheric particles nearby blast furnace and electric arc furnace operated industrial areas in Australia.

    Science.gov (United States)

    Mohiuddin, Kazi; Strezov, Vladimir; Nelson, Peter F; Stelcer, Eduard; Evans, Tim

    2014-07-15

    The improved understanding of mass and elemental distributions of industrial air particles is important due to their heterogeneous atmospheric behaviour and impact on human health and the environment. In this study, particles of different size ranges were collected from three sites in Australia located in the vicinity of iron and steelmaking industries and one urban background site with very little industrial influence. In order to determine the importance of the type of industrial activity on the urban atmospheric quality, the industrial sites selected in this study were in the close proximity to two blast furnace operated and one electric arc furnace based steelmaking sites. The chemical compositions of the collected air particles were analysed using the proton induced X-ray emission (PIXE) technique. This study revealed significantly higher metal concentrations in the atmospheric particles collected in the industrial sites, comparing to the background urban site, demonstrating local influence of the industrial activities to the air quality. The modality types of the particles were found to be variable between the mass and elements, and among elements in the urban and industrial areas indicating that the elemental modal distribution is as important as particle mass for particle pollution modelling. The highest elemental number distribution at all studied sites occurred with particle size of 0.1 μm. Iron was found as the main dominant metal at the industrial atmosphere in each particle size range. The industrial Fe fraction in the submicron and ultrafine size particles was estimated at up to 95% which may be released from high temperature industrial activities with the iron and steelmaking industries being one of the major contributors. Hence, these industrial elemental loadings can highly influence the atmospheric pollution at local urban and regional levels and are required to consider in the atmospheric modelling settings.

  17. Predictive analysis on the electric energy distribution systems reliability: applying the synerGEE system; Analisis predictivo de la confiabilidad en los sistemas de distribucion de energia electrica: aplicando el sistema synerGEE

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Andrade, Carlos

    2008-12-15

    Electrical distribution systems ought to deliver electric power as economical as possible with an acceptable degree of service quality and continuity. Nevertheless, their faults represent one of the main causes of customer's unavailability. At the moment, a wide range of determinist criteria in the improvement of systems reliability based on past behavior are used, but they do not respond to the stochastic nature of system behavior, and are applied without an adequate balance between reliability and economy. In order to obtain this balance a minimum cost planning methodology that considers the predictive analysis of different investment alternatives in addition to the past behavior of the system is required, which guarantees that the economic resource available and limited will be used to gather the greater possible reliability degree. In this work this problem is approached with the fundamentals and methodologies needed to assess the design effects and operative criteria over the main reliability indexes used by the main utilities around the world, with emphasis on the need to optimize economical resources. The use of the system SynerGEETM, is investigated, probing it as a useful tool for the predictive reliability analysis. Due to the lack of experience that exists in Mexico with this type of analysis, distribution engineers has to become familiar with the concepts of the reliability engineering, their application to establish distribution systems models, and acquiring the ability to use the modern simulation tools, allowing them to evaluate the behavior of these systems with enough analytical rigor. In this sense a serial of well known study cases are presented to help them in this labor. [Spanish] Los sistemas de distribucion de energia electrica deben satisfacer la demanda de energia electrica de la forma mas economica posible, con un grado de calidad y continuidad aceptable. Sin embargo, sus fallas son una de las principales causas de indisponibilidad en

  18. Hybrid instrument applied to human reliability study in event of loss of external electric power in a nuclear power plant; Instrumento hibrido aplicado ao estudo da confiabilidade humana em evento de perda de energia eletrica externa em usina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Eduardo Ferraz

    2015-04-01

    The study projects in highly complex installations involves robust modeling, supported by conceptual and mathematical tools, to carry out systematic research and structured the different risk scenarios that can lead to unwanted events from occurring equipment failures or human errors. In the context of classical modeling, the Probabilistic Safety Analysis (PSA) seeks to provide qualitative and quantitative information about the project particularity and their operational facilities, including the identification of factors or scenarios that contribute to the risk and consequent comparison options for increasing safety. In this context, the aim of the thesis is to develop a hybrid instrument (CPP-HI) innovative, from the integrated modeling techniques of Failure Mode and Effect Analysis (FMEA), concepts of Human Reliability Analysis and Probabilistic Composition of Preferences (PCP). In support of modeling and validation of the CPP-HI, a simulation was performed on a triggering event 'Loss of External Electric Power' - PEEE, in a Nuclear Power plant. The results were simulated in a virtual environment (sensitivity analysis) and are robust to the study of Human Reliability Analysis (HRA) in the context of the PSA. (author)

  19. Electrical machines diagnosis

    CERN Document Server

    Trigeassou, Jean-Claude

    2013-01-01

    Monitoring and diagnosis of electrical machine faults is a scientific and economic issue which is motivated by objectives for reliability and serviceability in electrical drives.This book provides a survey of the techniques used to detect the faults occurring in electrical drives: electrical, thermal and mechanical faults of the electrical machine, faults of the static converter and faults of the energy storage unit.Diagnosis of faults occurring in electrical drives is an essential part of a global monitoring system used to improve reliability and serviceability. This diagnosis is perf

  20. Office of Electricity Delivery and Energy Reliability (OE) National Energy Technology Laboratory (NETL) American Recovery and Reinvestment Act 2009 United States Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Mohit [Seeo, Incorporated, Hayward, CA (United States); Grape, Ulrik [Seeo, Incorporated, Hayward, CA (United States)

    2014-07-29

    The purpose of this project was for Seeo to deliver the first ever large-scale or grid-scale prototype of a new class of advanced lithium-ion rechargeable batteries. The technology combines unprecedented energy density, lifetime, safety, and cost. The goal was to demonstrate Seeo’s entirely new class of lithium-based batteries based on Seeo’s proprietary nanostructured polymer electrolyte. This technology can enable the widespread deployment in Smart Grid applications and was demonstrated through the development and testing of a 10 kilowatt-hour (kWh) prototype battery system. This development effort, supported by the United States Department of Energy (DOE) enabled Seeo to pursue and validate the transformational performance advantages of its technology for use in grid-tied energy storage applications. The focus of this project and Seeo’s goal as demonstrated through the efforts made under this project is to address the utility market needs for energy storage systems applications, especially for residential and commercial customers tied to solar photovoltaic installations. In addition to grid energy storage opportunities Seeo’s technology has been tested with automotive drive cycles and is seen as equally applicable for battery packs for electric vehicles. The goals of the project were outlined and achieved through a series of specific tasks, which encompassed materials development, scaling up of cells, demonstrating the performance of the cells, designing, building and demonstrating a pack prototype, and providing an economic and environmental assessment. Nearly all of the tasks were achieved over the duration of the program, with only the full demonstration of the battery system and a complete economic and environmental analysis not able to be fully completed. A timeline over the duration of the program is shown in figure 1.

  1. Proposed changes to generating capacity 1980-1989 for the contiguous United States: as projected by the Regional Electric Reliability Councils in their April 1, 1980 long-range coordinated planning reports to the Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-12-01

    The changes in generating capacity projected for 1980 to 1989 are summarized. Tabulated data provide summaries to the information on projected generating unit construction, retirements, and changes, in several different categories and groupings. The new generating units to be completed by the end of 1989 total 699, representing 259,490 megawatts. This total includes 10 wind power and one fuel cell installations totaling 48.5 MW to be completed by the end of 1989. There are 321 units totaling 13,222 MW to be retired. There are capacity changes due to upratings and deratings. Summary data are presented for: total requirement for electric energy generation for 1985; hydroelectric energy production for 1985; nuclear energy production for 1985; geothermal and other energy production for 1985; approximate non-fossil generation for 1985; range of fossil energy requirements for 1985; actual fossil energy sources 1974 to 1979; estimated range of fossil fuel requirements for 1985; coal capacity available in 1985; and computation of fuel use in 1985. Power plant capacity factors are presented. Extensive data on proposed generating capacity changes by individual units in the 9 Regional Electric Reliability Councils are presented.

  2. Photovoltaic performance and reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Mrig, L. [ed.

    1993-12-01

    This workshop was the sixth in a series of workshops sponsored by NREL/DOE under the general subject of photovoltaic testing and reliability during the period 1986--1993. PV performance and PV reliability are at least as important as PV cost, if not more. In the US, PV manufacturers, DOE laboratories, electric utilities, and others are engaged in the photovoltaic reliability research and testing. This group of researchers and others interested in the field were brought together to exchange the technical knowledge and field experience as related to current information in this evolving field of PV reliability. The papers presented here reflect this effort since the last workshop held in September, 1992. The topics covered include: cell and module characterization, module and system testing, durability and reliability, system field experience, and standards and codes.

  3. Mass and elemental distributions of atmospheric particles nearby blast furnace and electric arc furnace operated industrial areas in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Mohiuddin, Kazi, E-mail: kazi.mohiuddin@students.mq.edu.au [Graduate School of the Environment, Department of Environment and Geography, Faculty of Science, Macquarie University, NSW (Australia); Strezov, Vladimir; Nelson, Peter F. [Graduate School of the Environment, Department of Environment and Geography, Faculty of Science, Macquarie University, NSW (Australia); Stelcer, Eduard [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Evans, Tim [Graduate School of the Environment, Department of Environment and Geography, Faculty of Science, Macquarie University, NSW (Australia)

    2014-07-01

    The improved understanding of mass and elemental distributions of industrial air particles is important due to their heterogeneous atmospheric behaviour and impact on human health and the environment. In this study, particles of different size ranges were collected from three sites in Australia located in the vicinity of iron and steelmaking industries and one urban background site with very little industrial influence. In order to determine the importance of the type of industrial activity on the urban atmospheric quality, the industrial sites selected in this study were in the close proximity to two blast furnace operated and one electric arc furnace based steelmaking sites. The chemical compositions of the collected air particles were analysed using the proton induced X-ray emission (PIXE) technique. This study revealed significantly higher metal concentrations in the atmospheric particles collected in the industrial sites, comparing to the background urban site, demonstrating local influence of the industrial activities to the air quality. The modality types of the particles were found to be variable between the mass and elements, and among elements in the urban and industrial areas indicating that the elemental modal distribution is as important as particle mass for particle pollution modelling. The highest elemental number distribution at all studied sites occurred with particle size of 0.1 μm. Iron was found as the main dominant metal at the industrial atmosphere in each particle size range. The industrial Fe fraction in the submicron and ultrafine size particles was estimated at up to 95% which may be released from high temperature industrial activities with the iron and steelmaking industries being one of the major contributors. Hence, these industrial elemental loadings can highly influence the atmospheric pollution at local urban and regional levels and are required to consider in the atmospheric modelling settings. - Highlights: • Urban and

  4. Reliability optimal design of B-pillar for a hybrid electric vehicle in side impact%某混合动力汽车侧面碰撞中B柱可靠性优化设计

    Institute of Scientific and Technical Information of China (English)

    曹立波; 刘衡; 武和全

    2016-01-01

    对某混合动力汽车侧面碰撞B柱进行可靠性优化设计。设计中,结合试验设计理论、响应面模型、可靠性优化设计,基于产品质量工程,以中国新车评价规程(C-NCAP)和美国新车评价规程(US-NCAP)的侧面碰撞试验法规为基础,结合国内外交通事故调查统计数据。选取对汽车侧面碰撞安全性有重要影响的B柱内板、外板和加强板的壁厚和内板、外板材料屈服强度为设计变量。结果表明:在满足碰撞角度在-30°~30°和碰撞速度在40~60 km/h的混合动力汽车B柱耐撞性和可靠性要求条件下,90%、95%可靠性优化设计分别使得B柱质量降低了11.86%和10.34%。%A reliability optimization design was done for a B-pilar of a hybrid electric vehicle in side impact. The design combined using of experiments, the response surface models, the reliability theory and the reliability of design optimization method based on the product quality engineering, according to the side impact test regulations of the China New Car Assessment Program (C-NCAP) and the United States New Car Assessment Program (US-NCAP), and using the statistics from domestic and international trafifc accident investigation. The design variables were considered choosing the dimensions (such as thicknesses) and the materials (such as yield strengths) of the inner panel, the outer panel and the reinforcing plate, which play a major role in the safety performance in side impact crashes. The results show that this design makes the B-pilar mass decrease 11.86% and 10.34% respectively with the reliabilities of 90% and 95% with the impact angle in -30°~30° and impact velocity in 40~60 km/h.

  5. Energy-efficiency instruments in the electricity area; Instrumente fuer Energieeffizienz im Elektrizitaetsbereich. Auslaendische Erfahrungen und Instrumenten-Mix fuer die Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, S.; Oettli, B.; Schneider, Ch.; Iten, R. [Infras, Zuerich (Switzerland); Peherstorfer, N. [Oesterreichische Energieagentur, Wien (Austria)

    2007-06-15

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available.

  6. 3D electrical image in area contaminated by hydrocarbons at the Cubatao, Brazil, industrial pole; Imageamento eletrico 3D em area contaminada por hidrocarbonetono no polo industrial de Cubatao - SP, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Baessa, Marcus Paulus Martins [Centro de Pesquisas e Desenvolvimento Leopoldo Americo Miguez de Mello, CENPES, Rio de Janeiro, RJ (Brazil)], E-mail: marcus.baessa@petrobras.br; Oliva, Andresa; Kiang, Chang Hung [Universidade Estadual Paulista, UNESP, Rio Claro, SP (Brazil)], E-mails: aoliva@rc.unesp.br, chang@rc.unesp.br

    2010-12-15

    This work presents the results of geophysical surveys performed over an oil contaminated site in the Polo Industrial de Cubatao - Sao Paulo. The aim is to characterize geoelectrical signatures associated to hydrocarbon presence in order to delimit and calculate the volume of the contaminated area. For this study were used Vertical Electrical Sounding (VES) and 3D Electrical Imaging for characterization of geology and geoelectrical response of the contaminant. The results showed that the hydrocarbon presence is associated to conductive anomalies due to products from biodegradation. The conductive anomalies are disseminated over the area, totalizing 1365.3 m3 volume. This volume, however, corresponds only to the residual phase contaminants, since it was not possible to map free-phase hydrocarbons. (author)

  7. Class 1 overview of cultural resources for the Western Area Power Administration Salt Lake City Area Integrated Projects electric power marketing environmental impact statement

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, K.L.; Malinowski, L.M.; Hoffecker, J.F.; Walitschek, D.A.; Shogren, L.; Mathews, J.E.; Verhaaren, B.T.

    1993-11-01

    Argonne National Laboratory conducted an inventory of known archaeological and historic sites in areas that could be affected by the hydropower operation alternatives under analysis in the power marketing environmental impact statement for the Western Area Power Administration`s Salt Lake City Area Integrated Projects. The study areas included portions of the Green River (Flaming Gorge Dam to Cub Creek) in Utah and Colorado and the Gunnison River (Blue Mesa Reservoir to Crystal Dam) in Colorado. All previous archaeological surveys and previously recorded prehistoric and historic sites, structures, and features were inventoried and plotted on maps (only survey area maps are included in this report). The surveys were classified by their level of intensity, and the sites were classified according to their age, type, and contents. These data (presented here in tabular form) permit a general assessment of the character and distribution of archaeological remains in the study areas, as well as an indication of the sampling basis for such an assessment. To provide an adequate context for the descriptions of the archaeological and historic sites, this report also presents overviews of the environmental setting and the regional prehistory, history, and ethnography for each study area.

  8. 基于区域管制模式下的雷达信号通信可靠性分析%Reliability analysis of radar signal communication based on area control mode

    Institute of Scientific and Technical Information of China (English)

    沈仲针

    2014-01-01

    为了对区域管制模式下雷达信号传输系统的保障性进行定量评估,采用建立雷达信号传输可靠性数学模型的方法,并利用当前雷达信号传输保障数据对建立的模型进行了测算,从而得到了提高雷达信号传输可靠性的实现方法。%In order to evaluate the supportability of radar signal transmission system in area control mode, the method of establishing reliability mathematical model of radar signal transmission is used, and the radar signal transmission operation data is adopted to calculate the established model. Thus the method to improve the reliability of radar signal communication is obtained.

  9. Photovoltaic Module Reliability Workshop 2013: February 26-27, 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.

    2013-10-01

    NREL's Photovoltaic (PV) Module Reliability Workshop (PVMRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology--both critical goals for moving PV technologies deeper into the electricity marketplace.

  10. Photovoltaic Module Reliability Workshop 2010: February 18-19, 2010

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, J.

    2013-11-01

    NREL's Photovoltaic (PV) Module Reliability Workshop (PVMRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology--both critical goals for moving PV technologies deeper into the electricity marketplace.

  11. Photovoltaic Module Reliability Workshop 2011: February 16-17, 2011

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.

    2013-11-01

    NREL's Photovoltaic (PV) Module Reliability Workshop (PVMRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology--both critical goals for moving PV technologies deeper into the electricity marketplace.

  12. Photovoltaic Module Reliability Workshop 2014: February 25-26, 2014

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.

    2014-02-01

    NREL's Photovoltaic (PV) Module Reliability Workshop (PVMRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology--both critical goals for moving PV technologies deeper into the electricity marketplace.

  13. Photovoltaic Module Reliability Workshop 2012: February 28 - March 1, 2012

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.

    2013-11-01

    NREL's Photovoltaic (PV) Module Reliability Workshop (PVMRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology--both critical goals for moving PV technologies deeper into the electricity marketplace.

  14. Design for Reliability of Power Electronic Systems

    DEFF Research Database (Denmark)

    Wang, Huai; Ma, Ke; Blaabjerg, Frede

    2012-01-01

    Advances in power electronics enable efficient and flexible processing of electric power in the application of renewable energy sources, electric vehicles, adjustable-speed drives, etc. More and more efforts are devoted to better power electronic systems in terms of reliability to ensure high...... on a 2.3 MW wind power converter is discussed with emphasis on the reliability critical components IGBTs. Different aspects of improving the reliability of the power converter are mapped. Finally, the challenges and opportunities to achieve more reliable power electronic systems are addressed....

  15. Grid reliability

    CERN Document Server

    Saiz, P; Rocha, R; Andreeva, J

    2007-01-01

    We are offering a system to track the efficiency of different components of the GRID. We can study the performance of both the WMS and the data transfers At the moment, we have set different parts of the system for ALICE, ATLAS, CMS and LHCb. None of the components that we have developed are VO specific, therefore it would be very easy to deploy them for any other VO. Our main goal is basically to improve the reliability of the GRID. The main idea is to discover as soon as possible the different problems that have happened, and inform the responsible. Since we study the jobs and transfers issued by real users, we see the same problems that users see. As a matter of fact, we see even more problems than the end user does, since we are also interested in following up the errors that GRID components can overcome by themselves (like for instance, in case of a job failure, resubmitting the job to a different site). This kind of information is very useful to site and VO administrators. They can find out the efficien...

  16. Reliability of Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon

    . Structural reliability considerations and optimizations impact operation and maintenance (O&M) costs as well as the initial investment costs. Furthermore, there is a control system for WEC applications which defines the harvested energy but also the loads onto the structure. Therefore, extreme loads but also...... WEPTOS. Calibration of safety factors are performed for welded structures at theWavestar device including different control systems for harvesting energy from waves. In addition, a case study of different O&M strategies for WECs is discussed, and an example of reliability-based structural optimization......There are many different working principles for wave energy converters (WECs) which are used to produce electricity from waves. In order for WECs to become successful and more competitive to other renewable electricity sources, the consideration of the structural reliability of WECs is essential...

  17. [Restorative electric stimulation of the optic nerve in patients with diseases of the chiasmal-sellar area].

    Science.gov (United States)

    Khi'lko, V A; Gaĭdar, B V; Lyskov, E B; Kondra'teva, M I; Niko'lskaia, I M

    1989-01-01

    Presented is the clinical experience with vision restitution by direct electrostimulation (ES) of lesioned visual nerves in 128 operated patients with chiasmal-sellar diseases (chiasmal-sellar tumors and optico-chiasmatic arachnoiditis). Comparative analysis of ES-treated and control group was performed. Indications for this technique were determined in different forms of the disease depending on its severity and duration. ES showed positive results increasing the reliability and speed of vision restitution in operated patients.

  18. [Alteration of neural oscillations in hippocampal CA3 area in the fast avoidance response rat before and after electric shock avoidance training].

    Science.gov (United States)

    Wang, Wei-Wei; Wang, Dan-Dan; Wang, Dan; Guan, Yan; Tang, Ying-Ying; Ye, Zheng; Li, Jing; Li, Min; Zhu, Zai-Man; Pan, Qun-Wan

    2015-10-25

    The purpose of the present study is to explore the relationship of spatial learning ability and specific electrical activities of neural oscillations in the rat. The fast and general avoidance response groups were selected on the basis of the animals' responses to the electric shock in Y type maze, and their local field potentials (LFPs) of hippocampal CA3 area were recorded by wireless telemetry before and after shock avoidance training, respectively. The components of neural oscillations related to spatial identifying and learning ability were analyzed. The results showed that, compared with the general avoidance response group, the fast avoidance response group did not show any differences of LFPs in hippocampal CA3 area before electric shock avoidance trial, but showed significantly increased percentages of 0-10 Hz and 30-40 Hz rhythm in right hippocampal CA3 area after the shock avoidance training (P < 0.01 or P < 0.05). Fast Fourier transform showed that percentage increase of 0-10 Hz band occurred mainly in θ (3-7 Hz) frequency, and 30-40 Hz frequency change was equivalent to the γ1 band. Furthermore, compared with those before training, only the percentages of β, β2 (20-30 Hz) and γ1 rhythm increased (P < 0.01 or P < 0.05) in fast avoidance response rats after training, while the θ rhythm percentage remained unchanged. In contrast, θ rhythm percentage and the large amplitude (intensity: +2.5 - -2.5 db) θ waves in right CA3 area of general avoidance response rats were significantly reduced after training (P < 0.01). These results suggest that the increased percentages of β2 and γ1 rhythm and high-level (unchanged) percentage of θ rhythm in the right hippocampus CA3 area might be related to strong spatial cognition ability of fast avoidance response rats.

  19. Electric fields and electrical insulation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    2002-01-01

    The adoption of a field-theoretical approach to problems arising in the framework of electrical insulation is discussed with reference to six main topics, which have been addressed over the last 30 years. These include uniform field electrodes, Green's differential equation, electrode surface......, it is amply demonstrated that such an approach can lead to significant progress in many areas of electrical insulation....

  20. The Future of Electricity Resource Planning

    Energy Technology Data Exchange (ETDEWEB)

    Kahrl, Fredrich [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Mills, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lavin, Luke [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Ryan, Nancy [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Olsen, Arne [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-09-14

    Electricity resource planning is the process of identifying longer-term investments to meet electricity reliability requirements and public policy goals at a reasonable cost. Resource planning processes provide a forum for regulators, electric utilities, and electricity industry stakeholders to evaluate the economic, environmental, and social benefits and costs of different investment options. By facilitating a discussion on future goals, challenges and strategies, resource planning processes often play an important role in shaping utility business decisions. Resource planning emerged more than three decades ago in an era of transition, where declining electricity demand and rising costs spurred fundamental changes in electricity industry regulation and structure. Despite significant changes in the industry, resource planning continues to play an important role in supporting investment decision making. Over the next two decades, the electricity industry will again undergo a period of transition, driven by technological change, shifting customer preferences and public policy goals. This transition will bring about a gradual paradigm shift in resource planning, requiring changes in scope, approaches and methods. Even as it changes, resource planning will continue to be a central feature of the electricity industry. Its functions — ensuring the reliability of high voltage (“bulk”) power systems, enabling oversight of regulated utilities and facilitating low-cost compliance with public policy goals — are likely to grow in importance as the electricity industry enters a new period of technological, economic and regulatory change. This report examines the future of electricity resource planning in the context of a changing electricity industry. The report examines emerging issues and evolving practices in five key areas that will shape the future of resource planning: (1) central-scale generation, (2) distributed generation, (3) demand-side resources, (4

  1. Reliability Modeling of Wind Turbines

    DEFF Research Database (Denmark)

    Kostandyan, Erik

    and uncertainties are quantified. Further, estimation of annual failure probability for structural components taking into account possible faults in electrical or mechanical systems is considered. For a representative structural failure mode, a probabilistic model is developed that incorporates grid loss failures...... components. Thus, models of reliability should be developed and applied in order to quantify the residual life of the components. Damage models based on physics of failure combined with stochastic models describing the uncertain parameters are imperative for development of cost-optimal decision tools...... for Operation & Maintenance planning. Concentrating efforts on development of such models, this research is focused on reliability modeling of Wind Turbine critical subsystems (especially the power converter system). For reliability assessment of these components, structural reliability methods are applied...

  2. Expert system aids reliability

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, A.T. [Tennessee Gas Pipeline, Houston, TX (United States)

    1997-09-01

    Quality and Reliability are key requirements in the energy transmission industry. Tennessee Gas Co. a division of El Paso Energy, has applied Gensym`s G2, object-oriented Expert System programming language as a standard tool for maintaining and improving quality and reliability in pipeline operation. Tennessee created a small team of gas controllers and engineers to develop a Proactive Controller`s Assistant (ProCA) that provides recommendations for operating the pipeline more efficiently, reliably and safely. The controller`s pipeline operating knowledge is recreated in G2 in the form of Rules and Procedures in ProCA. Two G2 programmers supporting the Gas Control Room add information to the ProCA knowledge base daily. The result is a dynamic, constantly improving system that not only supports the pipeline controllers in their operations, but also the measurement and communications departments` requests for special studies. The Proactive Controller`s Assistant development focus is in the following areas: Alarm Management; Pipeline Efficiency; Reliability; Fuel Efficiency; and Controller Development.

  3. Reliability Analysis of DOOF for Weibull Distribution

    Institute of Scientific and Technical Information of China (English)

    陈文华; 崔杰; 樊小燕; 卢献彪; 相平

    2003-01-01

    Hierarchical Bayesian method for estimating the failure probability under DOOF by taking the quasi-Beta distribution as the prior distribution is proposed in this paper. The weighted Least Squares Estimate method was used to obtain the formula for computing reliability distribution parameters and estimating the reliability characteristic values under DOOF. Taking one type of aerospace electrical connector as an example, the correctness of the above method through statistical analysis of electrical connector accelerated life test data was verified.

  4. 75 FR 15371 - Time Error Correction Reliability Standard

    Science.gov (United States)

    2010-03-29

    ...Pursuant to section 215 of the Federal Power Act, the Commission proposes to remand the proposed revised Time Error Correction Reliability Standard developed by the North American Electric Reliability Corporation (NERC) in order for NERC to develop several modifications to the proposed Reliability Standard. The proposed action ensures that any modifications to Reliability Standards will be......

  5. Willingness to pay for public services and quality of supply in the electricity area; Zahlungsbereitschaft fuer Service public und Versorgungsqualitaet im Strombereich

    Energy Technology Data Exchange (ETDEWEB)

    Leukert, K.; Telser, H.; Vaterlaus, S.; Mahler, P.

    2008-07-01

    This report for the Swiss Federal Office of Energy (SFOE) takes a look at the results of a study made on the willingness to pay for public services and quality of supply in the electricity area. First, the starting point of the study and definitions of quality of supply and security of supply are noted. The methods used in the study are presented and macro-economic aspects are reviewed. The costs of black-outs are examined and the carrying out of surveys in the electricity market is discussed. The results of surveys made in households and commercial enterprises concerning the willingness to pay for security of supply and the costs incurred when supplies fail are presented and discussed. The report is completed with a comprehensive list of references and an appendix containing the results of the various tests and surveys made.

  6. Frontiers of reliability

    CERN Document Server

    Basu, Asit P; Basu, Sujit K

    1998-01-01

    This volume presents recent results in reliability theory by leading experts in the world. It will prove valuable for researchers, and users of reliability theory. It consists of refereed invited papers on a broad spectrum of topics in reliability. The subjects covered include Bayesian reliability, Bayesian reliability modeling, confounding in a series system, DF tests, Edgeworth approximation to reliability, estimation under random censoring, fault tree reduction for reliability, inference about changes in hazard rates, information theory and reliability, mixture experiment, mixture of Weibul

  7. 76 FR 42534 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits; System...

    Science.gov (United States)

    2011-07-19

    ... Reliability Operating Limits; System Restoration Reliability Standards AGENCY: Federal Energy Regulatory... necessary to analyze and monitor Interconnection Reliability Operating Limits (IROL) within its Wide-Area... Interconnection Reliability Operating Limits, Order No. 748, 134 FERC ] 61,213 (2011). \\2\\ The term...

  8. Reliability evaluation for offshore wind farms

    DEFF Research Database (Denmark)

    Zhao, Menghua; Blåbjerg, Frede; Chen, Zhe

    2005-01-01

    In this paper, a new reliability index - Loss Of Generation Ratio Probability (LOGRP) is proposed for evaluating the reliability of an electrical system for offshore wind farms, which emphasizes the design of wind farms rather than the adequacy for specific load demand. A practical method...... to calculate LOGRP of offshore wind farms is proposed and evaluated....

  9. Construction of Electrical Business Incubation Park Based on Cross -Border Electricity Experimental Area%基于跨境电商实验区的残疾人电商孵化园建设研究

    Institute of Scientific and Technical Information of China (English)

    王冠

    2015-01-01

    Programs for the disabled is an important part of the cause of socialism with Chinese characteristics for the group to create wider employment and entrepreneurial opportunities,which can effectively promote the special groups involved in the de-velopment of social construction and is advantageous to the protection of disable people equality,participation,share right to survival and development.With the development of Internet +,e -commerce has become one of the important ways of entre-preneurship and employment.Based on this platform,setting up disabled electricity hatcheries facilitate electricity employment for the disabled based on cross -border electricity experimental area.At the same time,according to the characteristics of the handicapped craftsmanship design can meet the demand of their electrical business incubation park project,solve the employ-ment of the disability categories,disability grade groups,and help its true self -reliance based society.%残疾人事业是中国特色社会主义事业重要组成部分,为该群体创设辐射更广的就业、创业机会,能有效促进特殊群体参与到社会建设发展中,有利于保障残疾人平等、参与、共享的生存权和发展权。随着互联网+发展的新业态,基于跨境电商实验区建立残疾人电商孵化园有助于推动残疾人电商就业,帮助其真正自力更生立足社会。

  10. Discussion on the Approaches to Save Electrical Energy in Salt Production Area%探讨盐区节约电能的途径

    Institute of Scientific and Technical Information of China (English)

    刘金荣

    2012-01-01

    The Aapproaches to save electrial energy in salt production area are introduced in the article. To do this, that design of electric power, loss in wire, energy saving of lighting and power consumption mangement in salt field is preliminary discussed.%文章阐述了盐区节约电能的途径,主要对电力设计、线路损耗,照明节电,及盐田用电管理进行初步探讨.

  11. 77 FR 10486 - Electricity Advisory Committee Meeting

    Science.gov (United States)

    2012-02-22

    ... Electricity Advisory Committee Meeting AGENCY: Office of Electricity Delivery and Energy Reliability... Electricity Advisory Committee (EAC). The Federal Advisory Committee Act (Pub. L. 92- 463, 86 Stat. 770... INFORMATION CONTACT: Matthew Rosenbaum, Office of Electricity Delivery and Energy Reliability, U.S....

  12. 78 FR 55692 - Electricity Advisory Committee

    Science.gov (United States)

    2013-09-11

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of Energy. ACTION: Notice of open meeting. SUMMARY: This notice announces a meeting of the Electricity... INFORMATION CONTACT: Matthew Rosenbaum, Office of Electricity Delivery and Energy Reliability, U.S....

  13. 76 FR 10577 - Electricity Advisory Committee Meeting

    Science.gov (United States)

    2011-02-25

    ... Electricity Advisory Committee Meeting AGENCY: Office of Electricity Delivery and Energy Reliability... reestablished Electricity Advisory Committee (EAC). The Federal Advisory Committee Act (Pub. L. 92-463, 86 Stat... of Electricity Delivery and Energy Reliability, U.S. Department of Energy, Forrestal Building,...

  14. 78 FR 28207 - Electricity Advisory Committee

    Science.gov (United States)

    2013-05-14

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of Energy. ACTION: Notice of open meeting. SUMMARY: This notice announces a meeting of the Electricity... CONTACT: Matthew Rosenbaum, Office of Electricity Delivery and Energy Reliability, U.S. Department...

  15. 78 FR 9038 - Electricity Advisory Committee Meeting

    Science.gov (United States)

    2013-02-07

    ... Electricity Advisory Committee Meeting AGENCY: Office of Electricity Delivery and Energy Reliability... Electricity Advisory Committee (EAC). The Federal Advisory Committee Act (Pub. L. 92-463, 86 Stat. 770... FURTHER INFORMATION CONTACT: Matthew Rosenbaum, Office of Electricity Delivery and Energy Reliability,...

  16. 77 FR 29995 - Electricity Advisory Committee

    Science.gov (United States)

    2012-05-21

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of Energy. ACTION: Notice of open meeting. SUMMARY: This notice announces a meeting of the Electricity... of Electricity Delivery and Energy Reliability, U.S. Department of Energy, Forrestal Building,...

  17. 77 FR 58534 - Electricity Advisory Committee

    Science.gov (United States)

    2012-09-21

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of Energy. ACTION: Notice of open meeting. SUMMARY: This notice announces a meeting of the Electricity... of Electricity Delivery and Energy Reliability, U.S. Department of Energy, Forrestal Building,...

  18. 76 FR 59667 - Electricity Advisory Committee

    Science.gov (United States)

    2011-09-27

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of Energy. ACTION: Notice of open meeting. SUMMARY: This notice announces a meeting of the Electricity... CONTACT: David Meyer, Office of Electricity Delivery and Energy Reliability, U.S. Department of...

  19. 77 FR 49441 - Electricity Advisory Committee

    Science.gov (United States)

    2012-08-16

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of... that the Electricity Advisory ] Committee's (EAC) charter has been renewed for a two-year period... Secretary for Electricity Delivery and Energy Reliability on programs to modernize the Nation's...

  20. Reliable processing of graphene using metal etchmasks

    Directory of Open Access Journals (Sweden)

    Peltekis Nikos

    2011-01-01

    Full Text Available Abstract Graphene exhibits exciting properties which make it an appealing candidate for use in electronic devices. Reliable processes for device fabrication are crucial prerequisites for this. We developed a large area of CVD synthesis and transfer of graphene films. With patterning of these graphene layers using standard photoresist masks, we are able to produce arrays of gated graphene devices with four point contacts. The etching and lift off process poses problems because of delamination and contamination due to polymer residues when using standard resists. We introduce a metal etch mask which minimises these problems. The high quality of graphene is shown by Raman and XPS spectroscopy as well as electrical measurements. The process is of high value for applications, as it improves the processability of graphene using high-throughput lithography and etching techniques.

  1. Delta-Reliability

    OpenAIRE

    Eugster, P.; Guerraoui, R.; Kouznetsov, P.

    2001-01-01

    This paper presents a new, non-binary measure of the reliability of broadcast algorithms, called Delta-Reliability. This measure quantifies the reliability of practical broadcast algorithms that, on the one hand, were devised with some form of reliability in mind, but, on the other hand, are not considered reliable according to the ``traditional'' notion of broadcast reliability [HT94]. Our specification of Delta-Reliability suggests a further step towards bridging the gap between theory and...

  2. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  3. Effects of sympathetic stimulation on the rhythmical jaw movements produced by electrical stimulation of the cortical masticatory areas of rabbits.

    Science.gov (United States)

    Roatta, S; Windhorst, U; Djupsjöbacka, M; Lytvynenko, S; Passatore, M

    2005-03-01

    The somatomotor and sympathetic nervous systems are intimately linked. One example is the influence of peripheral sympathetic fibers on the discharge characteristics of muscle spindles. Since muscle spindles play important roles in various motor behaviors, including rhythmic movements, the working hypothesis of this research was that changes in sympathetic outflow to muscle spindles can change rhythmic movement patterns. We tested this hypothesis in the masticatory system of rabbits. Rhythmic jaw movements and EMG activity induced by long-lasting electrical cortical stimulation were powerfully modulated by electrical stimulation of the peripheral stump of the cervical sympathetic nerve (CSN). This modulation manifested itself as a consistent and marked reduction in the excursion of the mandibular movements (often preceded by a transient modest enhancement), which could be attributed mainly to corresponding changes in masseter muscle activity. These changes outlasted the duration of CSN stimulation. In some of the cortically evoked rhythmic jaw movements (CRJMs) changes in masticatory frequency were also observed. When the jaw-closing muscles were subjected to repetitive ramp-and-hold force pulses, the CRMJs changed characteristics. Masseter EMG activity was strongly enhanced and digastric EMG slightly decreased. This change was considerably depressed during CSN stimulation. These effects of CSN stimulation are similar in sign and time course to the depression exerted by sympathetic activity on the jaw-closing muscle spindle discharge. It is suggested that the change in proprioceptive information induced by an increase in sympathetic outflow (a) has important implications even under normal conditions for the control of motor function in states of high sympathetic activity, and (b) is one of the mechanisms responsible for motor impairment under certain pathological conditions such as chronic musculoskeletal head-neck disorders, associated with stress conditions.

  4. Improved reliability of power modules

    DEFF Research Database (Denmark)

    Baker, Nick; Liserre, Marco; Dupont, Laurent

    2014-01-01

    Power electronic systems play an increasingly important role in providing high-efficiency power conversion for adjustable-speed drives, power-quality correction, renewable-energy systems, energy-storage systems, and electric vehicles. However, they are often presented with demanding operating...... environments that challenge the reliability aspects of power electronic techniques. For example, increasingly thermally stressful environments are seen in applications such as electric vehicles, where ambient temperatures under the hood exceed 150 °C, while some wind turbine applications can place large...

  5. Additions to generating capacity 1978--1987 for the contiguous United States: as projected by the Regional Electric Reliability Councils in their April 1, 1978 long-range coordinated planning reports to the Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    1978-09-15

    Comparison of the 1978 projections of the Reliability Councils with those made the previous year indicates three major changes in electric utility planning: (1) a reduction in total capacity additions for the 10-year planning period, (2) a significant decrease in nuclear additions, and (3) a shift from oil and gas to coal as a source of primary energy. Nuclear capacity continues to far overshadow fossil-fuel capacity in the unit-size range 1000 MW and up, with the reverse true for unit sizes less than 1000 MW. Although the total 10-year new-unit capacity drops from 326,624 MW (1977 to 1986) to 308,017 (1978 to 1987), new capacity planned that would use coal as a primary energy source increases from 136,763 MW to 146,206 MW. Nuclear capacity, in terms of total new units projected for the two 10-year periods, decreases from 130,532 MW to 116,177 MW, and capacity with oil as the primary source drops from 32,837 MW to 21,072 MW. For 1977 to 1986, no capacity was planned with oil as a primary source and coal as an alternate fuel but for 1978 to 1987, 1220 MW of such capacity is projected. Therefore, the total new capacity projected that could use coal as a fuel (primary or alternate) is 147,426 MW. In addition, one 700-MW unit is planned for which the primary fuel will be a blend of coal and refuse. There is a decrease in the capacity planned that would use natural gas a a primary source, from 2,089 MW in 1977 to 1986 to 502 MW in 1978 to 1987.

  6. Reliability of Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon

    for welded structures at the Wavestar device includingdifferent control systems for harvesting energy from waves. In addition, a casestudy of different O&M strategies for WECs is discussed, and an example ofreliability-based structural optimization of the Wavestar foundation ispresented. The work performed......There are many different working principles for wave energy converters (WECs) which are used to produce electricity from waves. In order for WECs tobecome successful and more competitive to other renewable electricity sources,the consideration of the structural reliability of WECs is essential.......Structural reliability considerations and optimizations impact operation andmaintenance (O&M) costs as well as the initial investment costs.Furthermore, there is a control system for WEC applications which defines theharvested energy but also the loads onto the structure. Therefore, extremeloads but also fatigue loads...

  7. Association Analysis of System Failure in Wide Area Backup Protection System

    Science.gov (United States)

    Zhang, Yagang; Sun, Yi

    2015-12-01

    Wide area backup protection algorithm based on fault component identification is the heart of the whole wide area backup protection system, its validity and reliability is a problem which needs to be first considered in the engineering practice applications of wide area backup protection system. Wide are backup protection algorithm mainly use two kinds of wide area information to realize protection criterion, one is electrical quantity information, such as voltage, current, etc. Another one is protection action and circuit breaker information. The wide area backup protection algorithm based on electrical quantity information is mainly utilizing the significant change of electrical quantity to search fault component, and the primary means include current differential method of wide area multi-measuring points, the comparison method of calculation and measurement, the multiple statistics method. In this paper, a novel and effective association analysis of system failure in wide area backup protection system will be discussed carefully, and the analytical results are successful and reliable.

  8. A combined morphostructural/fluid migration model of Pisciarelli area (Campi Flegrei caldera - CFc) through structural and integrated Terrestrial Laser Scanner (TLS) and Electrical Resistivity Tomography (ERT) analysis.

    Science.gov (United States)

    Caputo, Teresa; Di Giuseppe, Maria Guilia; Troiano, Antonio; Somma, Renato; Isaia, Roberto; Vitale, Stefano; Troise, Claudia; De Natale, Giuseppe

    2014-05-01

    diffuse degassing, mainly in correspondence to fractures and faults. The TLS analysis of the area was performed applying the technique based on Time of Flight method in order to define an accurate 3D digital model for detailed analysis of this area. Several scans were performed in order to avoid shaded areas due to the presence of either fumaroles than soil degassing. The dense vapour emission in the area, in fact limits the ability of penetration of the laser scanner. Electrical measurements has been acquired to reconstruct the spatial distribution of the electrical resistivity, which is a physical parameter particularly sensitive to the presence of low-resistivity phases, such as aqueous fluids and partial melts. In such a way, the volume of subsurface fluids has been constrained and the rheology of the subsoil in the Pisciarelli area has been reconstructed. Combining all the data a structural and geomorphological model of the area has been obtained. Similar dataset could be acquired in the future in order to estimate any structural changes that may occur in this interesting volcanic area therefore providing a better hazard assessment.

  9. Reliability Assessment of Wind Turbines

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2015-01-01

    Wind turbines can be considered as structures that are in between civil engineering structures and machines since they consist of structural components and many electrical and machine components together with a control system. Further, a wind turbine is not a one-of-a-kind structure...... but manufactured in series production based on many component tests, some prototype tests and zeroseries wind turbines. These characteristics influence the reliability assessment where focus in this paper is on the structural components. Levelized Cost Of Energy is very important for wind energy, especially when...... comparing to other energy sources. Therefore much focus is on cost reductions and improved reliability both for offshore and onshore wind turbines. The wind turbine components should be designed to have sufficient reliability level with respect to both extreme and fatigue loads but also not be too costly...

  10. Reliability assessment of Wind turbines

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2015-01-01

    Wind turbines can be considered as structures that are in between civil engineering structures and machines since they consist of structural components and many electrical and machine components together with a control system. Further, a wind turbine is not a one-of-a-kind structure...... but manufactured in series production based on many component tests, some prototype tests and zeroseries wind turbines. These characteristics influence the reliability assessment where focus in this paper is on the structural components. Levelized Cost Of Energy is very important for wind energy, especially when...... comparing to other energy sources. Therefore much focus is on cost reductions and improved reliability both for offshore and onshore wind turbines. The wind turbine components should be designed to have sufficient reliability level with respect to both extreme and fatigue loads but also not be too costly...

  11. Implementation Planning and Reliability Analysis of Guangdong Hengqin New Area Smart Grid%广东横琴新区智能电网实施规划及可靠性分析

    Institute of Scientific and Technical Information of China (English)

    余南华; 刘洪; 陈辉

    2012-01-01

    Hengqin island of Guangdong is located at the junction of China mainland, Hong Kong and Macao, which is the thirdnational level new area. The general idea and development objectives of construction planning for Hengqin new area (HNA) smart grid project is introduced, and the technical characteristics and contents, including the intelligent operation center, on- line monitoring of terminal units, distribution automation, distributed energy resources and vehicle-to-grid, home management system, data acquisition for power consumption and demand side management are presented. The influence factors for smart grid reliability and the supporting measures to enhance the reliability are also analyzed.%广东横琴岛是位于粤港澳三地交界的中国第3个国家级新区。文中介绍了横琴新区智能电网建设规划的总体思路和发展目标;阐述了其技术特征及内涵,包括智能运行维护中心、终端在线监测、配电自动化、分布式电源及电动汽车并网、智能小区和智能家居、用电信息采集与需求侧管理等。全面分析了智能电网可靠性的影响因素,以及提升可靠性的保障措施。

  12. 77 FR 27574 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards

    Science.gov (United States)

    2012-05-11

    ... event assessment differences do not pose a risk to the reliability of the bulk electric system, with EEI... Electric Reliability Corporation (NERC), the Electric Reliability Organization certified by the Commission... to frequency degradation. The Commission approves, with modifications, the related Violation...

  13. VLSI Reliability in Europe

    NARCIS (Netherlands)

    Verweij, Jan F.

    1993-01-01

    Several issue's regarding VLSI reliability research in Europe are discussed. Organizations involved in stimulating the activities on reliability by exchanging information or supporting research programs are described. Within one such program, ESPRIT, a technical interest group on IC reliability was

  14. 青少年生活事件量表灾区正式版的信效度检验%Reliability and Validity of the Adolescent Self-Rating Life Events Check List-Formal in disaster area

    Institute of Scientific and Technical Information of China (English)

    张宇; 廖彩之; 魏青

    2015-01-01

    Objective:To evaluate the reliability and validity of the Adolescent Self -Rating Life E-vents Check-list-Formal of in disaster area .Methods:The Adolescent Self-Rating Life Events Check-list was administered to a sample of Qingchuan students ( n=1550 ) aged 9 to 19 ,the data was analyzed by SPSS 15.0 and AMOS 7.0.Results:①Confirmatory factor analysis revealed that the original model did not fit this Qingchuan sample well .However ,the deletion of three items ( items 5 ,16 and 27 ) resulted in a model with six identifiable factors:Study pressure ,being punished ,health,interpersonal relationship , being frustrated,lossing,accounting for 49.94% of the total variance; ② The internal reliability coeffi-cient of the whole scale was 0.86,the split half reliability was 0.82,the test-retest reliability coefficients of two weeks of three scales were:0.60 -0.76.Conclusion:The Adolescent Self -Rating Life Events Check List-Formal( ASLEC-F) in disaster area indicates good psychometrics properties with adequate reliability and validity ,it can be a useful self -rating diagnostic instrument for survivors with PTSD symp-tom.%目的:评估《灾区学生创伤反应追踪调查与校园介入方案研究》中施测工具青少年生活事件量表灾区正式版( ASLEC-F)的信效度。方法:采用青少年生活事件量表( ASLEC)对青川县1700名中小学生施测并获得有效数据1550份,采用SPSS 15.0以及AMOS 7.0检验量表的信效度。结果:①通过探索性和验证性因子分析,删除原量表的3个题项(5、16、27题),获得适合本次研究的6因素结构(学习压力因子、受惩罚因子、健康因子、人际关系因子、受挫折因子和丧失因子)的青少年生活事件量表灾区正式版,6个因子解释总方差为49.94%;②生活事件量表灾区正式版内部一致性系数0.86,量表的分半信度系数为0.82。2周后的重测系数为:0.60~0.76。结论:青少

  15. [The role of histamine in regulation of spontaneous electrical activity of the rat ureter and bordering to bladder area].

    Science.gov (United States)

    Kazarian, K V; Vantsian, B Ts; Simonian, L G

    2011-12-01

    The nature of the influence of histamine on the slow wave and spike spontaneous activity of both perirenal and peribladder bordering areas of the bladder zone has been studied. It is shown that under these conditions of activated renal section of the organ, in the distal part, the decrease in frequency of the slow waves occurred. The histamine effect also contributes to improvement of the conduction of the excitation wave propagating to the bladder, which destroys the coordination of spike activity of the latter with slow waves of ureteral bordering zone.

  16. Deep electrical resistivity tomography and geothermal analysis of Bradano foredeep deposits in Venosa area (Southern Italy: preliminary results

    Directory of Open Access Journals (Sweden)

    V. Lapenna

    2008-06-01

    Full Text Available Geophysical surveys have been carried out to characterize the stratigraphical and structural setting and to better understand the deep water circulation system in the Venosa area (Southern Italy located in the frontal portion of the southern Appenninic Subduction. In this area there are some deep water wells from which a water conductivity of about 3 mS/cm and a temperature of about 35°C was measured. A deep geoelectrical tomography with dipole-dipole array has been carried out along a profile of 10000 m and an investigation depth of about 900 m. Furthermore a broad band magnetotelluric profile consisting of six stations was performed to infer the resistivity distribution up to some kilometres of depth. The MT profile was almost coincident with the geoelectrical outline. The applied methods allow us to obtain a mutual control and integrated interpretation of the data. The high resolution of the data was the key to reconstruct the structural asset of buried carbonatic horst whose top is located at about 600 m depth. The final results coming from data wells, geothermal analysis and geophysical data, highlighted a horst saturated with salted water and an anomalous local gradient of 60°C/km. The proposed mechanism is that of a mixing of fossil and fresh water circulation system.

  17. Advances in reliability and system engineering

    CERN Document Server

    Davim, J

    2017-01-01

    This book presents original studies describing the latest research and developments in the area of reliability and systems engineering. It helps the reader identifying gaps in the current knowledge and presents fruitful areas for further research in the field. Among others, this book covers reliability measures, reliability assessment of multi-state systems, optimization of multi-state systems, continuous multi-state systems, new computational techniques applied to multi-state systems and probabilistic and non-probabilistic safety assessment.

  18. Deep electrical resistivity tomography along the tectonically active Middle Aterno Valley (2009 L'Aquila earthquake area, central Italy)

    Science.gov (United States)

    Pucci, Stefano; Civico, Riccardo; Villani, Fabio; Ricci, Tullio; Delcher, Eric; Finizola, Anthony; Sapia, Vincenzo; De Martini, Paolo Marco; Pantosti, Daniela; Barde-Cabusson, Stéphanie; Brothelande, Elodie; Gusset, Rachel; Mezon, Cécile; Orefice, Simone; Peltier, Aline; Poret, Matthieu; Torres, Liliana; Suski, Barbara

    2016-11-01

    Three 2-D Deep Electrical Resistivity Tomography (ERT) transects, up to 6.36 km long, were obtained across the Paganica-San Demetrio Basin, bounded by the 2009 L'Aquila Mw 6.1 normal-faulting earthquake causative fault (central Italy). The investigations allowed defining for the first time the shallow subsurface basin structure. The resistivity images, and their geological interpretation, show a dissected Mesozoic-Tertiary substratum buried under continental infill of mainly Quaternary age due to the long-term activity of the Paganica-San Demetrio normal faults system (PSDFS), ruling the most recent deformational phase. Our results indicate that the basin bottom deepens up to 600 m moving to the south, with the continental infill largely exceeding the known thickness of the Quaternary sequence. The causes of this increasing thickness can be: (1) the onset of the continental deposition in the southern sector took place before the Quaternary, (2) there was an early stage of the basin development driven by different fault systems that produced a depocentre in the southern sector not related to the present-day basin shape, or (3) the fault system slip rate in the southern sector was faster than in the northern sector. We were able to gain sights into the long-term PSDFS behaviour and evolution, by comparing throw rates at different timescales and discriminating the splays that lead deformation. Some fault splays exhibit large cumulative throws (>300 m) in coincidence with large displacement of the continental deposits sequence (>100 m), thus testifying a general persistence in time of their activity as leading splays of the fault system. We evaluate the long-term (3-2.5 Myr) cumulative and Quaternary throw rates of most of the leading splays to be 0.08-0.17 mm yr-1, indicating a substantial stability of the faults activity. Among them, an individual leading fault splay extends from Paganica to San Demetrio ne' Vestini as a result of a post-Early Pleistocene linkage of

  19. Surface Area Expansion of Electrodes with Grass-like Nanostructures to Enhance Electricity Generation in Microbial Fuel Cells

    DEFF Research Database (Denmark)

    Al Atraktchi, Fatima Al-Zahraa; Zhang, Yifeng; Noori, Jafar Safaa;

    2012-01-01

    Microbial fuel cells (MFCs) have applications possibilities for wastewater treatment, biotransformation, and biosensor, but the development of highly efficient electrode materials is critical for enhancing the power generation. Two types of electrodes modified with nanoparticles or grass-like nan......Microbial fuel cells (MFCs) have applications possibilities for wastewater treatment, biotransformation, and biosensor, but the development of highly efficient electrode materials is critical for enhancing the power generation. Two types of electrodes modified with nanoparticles or grass...... of plain silicium showed a maximum power density of 86.0 mW/m2. Further expanding the surface area of carbon paper electrodes with gold nanoparticles resulted in a maximum stable power density of 346.9 mW/m2 which is 2.9 times higher than that achieved with conventional carbon paper. These results show...... that fabrication of electrodes with nanograss could be an efficient way to increase the power generation....

  20. Structural Reliability Methods for Wind Power Converter System Component Reliability Assessment

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2012-01-01

    is defined by the threshold model. The attention is focused on crack propagation in solder joints of electrical components due to the temperature loadings. Structural Reliability approaches are used to incorporate model, physical and statistical uncertainties. Reliability estimation by means of structural...

  1. 3D electric resistivity tomography (ERT) methodologies applied on selected heavily urbanized areas of the basin of Mexico to detect buried fractures and subsidence problems

    Science.gov (United States)

    Chavez Segura, R. E.; Cifuentes-Nava, G.; Tejero, A.; Hernandez, E.

    2012-12-01

    Urban development in modern cities require of a more integral knowledge of the subsurface, mainly on those areas, where human concentrations increase. Mexico City is one of such an example, where it constitutes one of the largest concentrations of human activities in the world. Most of the urban area is underlain by lacustrine sediments of the former lakes, and confined by important volcanic ranges. Such sediments offer poor foundation conditions for constructive purposes. Therefore, high risk areas have to be identified to prevent accidents and disastrous events. Geophysical techniques can be employed to understand the physical characteristics of the subsurface. Two examples are presented in this investigation. A residential complex named La Concordia is located towards the central portion of the basin that consists of six four storey buildings in an area of 33x80 m2. Finally, a block of small houses (50x50 m2) is found to the southern limit of the basin; close to the Chichinautzin range within the town of Tecomitl. Both zones suffer of strong damage in their structures due to fractures and subsidence within the subsoil. Therefore, Electric Resistivity Tomography (ERT) was carried out to characterize the subsoil beneath these urban complexes. A special array ('horse-shoe' geometry) 'L' employing Wenner-Schlumberger techniques, in addition to equatorial-dipole and minimum-coupling arrays were carried out to fully 'illuminate' beneath the constructions. Computed resistivity models for both examples depicted the buried fracture pattern affecting the urban complexes. Such patterns seem to extend beyond the limits of the surveyed areas, and are probably part of a more complex fracture system. It is very likely that fractures have been produced due to the poorly consolidated clays that cover most of the central part of the Valley of Mexico; the intense water extraction, that form 'voids' in the subsoil causing subsidence effects and finally the existence of regional

  2. A 200-Channel Area-Power-Efficient Chemical and Electrical Dual-Mode Acquisition IC for the Study of Neurodegenerative Diseases.

    Science.gov (United States)

    Guo, Jing; Ng, Waichiu; Yuan, Jie; Li, Suwen; Chan, Mansun

    2016-06-01

    Microelectrode array (MEA) can be used in the study of neurodegenerative diseases by monitoring the chemical neurotransmitter release and the electrical potential simultaneously at the cellular level. Currently, the MEA technology is migrating to more electrodes and higher electrode density, which raises power and area constraints on the design of acquisition IC. In this paper, we report the design of a 200-channel dual-mode acquisition IC with highly efficient usage of power and area. Under the constraints of target noise and fast settling, the current channel design saves power by including a novel current buffer biased in discrete time (DT) before the TIA (transimpedance amplifier). The 200 channels are sampled at 20 kS/s and quantized by column-wise SAR ADCs. The prototype IC was fabricated in a 0.18 μm CMOS process. Silicon measurements show the current channel has 21.6 pArms noise with cyclic voltammetry (CV) and 0.48 pArms noise with constant amperometry (CA) while consuming 12.1 μW . The voltage channel has 4.07 μVrms noise in the bandwidth of 100 kHz and 0.2% nonlinearity while consuming 9.1 μW. Each channel occupies 0.03 mm(2) area, which is among the smallest.

  3. Reliability of Power Units in Poland and the World

    Directory of Open Access Journals (Sweden)

    Józef Paska

    2015-09-01

    Full Text Available One of a power system’s subsystems is the generation subsystem consisting of power units, the reliability of which to a large extent determines the reliability of the power system and electricity supply to consumers. This paper presents definitions of the basic indices of power unit reliability used in Poland and in the world. They are compared and analysed on the basis of data published by the Energy Market Agency (Poland, NERC (North American Electric Reliability Corporation – USA, and WEC (World Energy Council. Deficiencies and the lack of a unified national system for collecting and processing electric power equipment unavailability data are also indicated.

  4. Cost-effective solutions to maintaining smart grid reliability

    Science.gov (United States)

    Qin, Qiu

    As the aging power systems are increasingly working closer to the capacity and thermal limits, maintaining an sufficient reliability has been of great concern to the government agency, utility companies and users. This dissertation focuses on improving the reliability of transmission and distribution systems. Based on the wide area measurements, multiple model algorithms are developed to diagnose transmission line three-phase short to ground faults in the presence of protection misoperations. The multiple model algorithms utilize the electric network dynamics to provide prompt and reliable diagnosis outcomes. Computational complexity of the diagnosis algorithm is reduced by using a two-step heuristic. The multiple model algorithm is incorporated into a hybrid simulation framework, which consist of both continuous state simulation and discrete event simulation, to study the operation of transmission systems. With hybrid simulation, line switching strategy for enhancing the tolerance to protection misoperations is studied based on the concept of security index, which involves the faulted mode probability and stability coverage. Local measurements are used to track the generator state and faulty mode probabilities are calculated in the multiple model algorithms. FACTS devices are considered as controllers for the transmission system. The placement of FACTS devices into power systems is investigated with a criterion of maintaining a prescribed level of control reconfigurability. Control reconfigurability measures the small signal combined controllability and observability of a power system with an additional requirement on fault tolerance. For the distribution systems, a hierarchical framework, including a high level recloser allocation scheme and a low level recloser placement scheme, is presented. The impacts of recloser placement on the reliability indices is analyzed. Evaluation of reliability indices in the placement process is carried out via discrete event

  5. Ultra-low switching energy and scaling in electric-field-controlled nanoscale magnetic tunnel junctions with high resistance-area product

    Energy Technology Data Exchange (ETDEWEB)

    Grezes, C.; Alzate, J. G.; Cai, X.; Wang, K. L. [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); Ebrahimi, F.; Khalili Amiri, P. [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); Inston, Inc., Los Angeles, California 90024 (United States); Katine, J. A. [HGST, Inc., San Jose, California 95135 (United States); Langer, J.; Ocker, B. [Singulus Technologies AG, Kahl am Main 63796 (Germany)

    2016-01-04

    We report electric-field-induced switching with write energies down to 6 fJ/bit for switching times of 0.5 ns, in nanoscale perpendicular magnetic tunnel junctions (MTJs) with high resistance-area product and diameters down to 50 nm. The ultra-low switching energy is made possible by a thick MgO barrier that ensures negligible spin-transfer torque contributions, along with a reduction of the Ohmic dissipation. We find that the switching voltage and time are insensitive to the junction diameter for high-resistance MTJs, a result accounted for by a macrospin model of purely voltage-induced switching. The measured performance enables integration with same-size CMOS transistors in compact memory and logic integrated circuits.

  6. Different Reliability Assessment Approaches for Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kramer, Morten Mejlhede; Sørensen, John Dalsgaard

    2015-01-01

    Reliability assessments are of importance for wave energy converters (WECs) due to the fact that accessibility might be limited in case of failure and maintenance. These failure rates can be adapted by reliability considerations. There are two different approaches to how reliability can...... be estimated: the so-called classical reliability theory and the probabilistic reliability theory. The classical reliability theory is often used for failure rate estimations of mechanical and electrical components, whereas the probabilistic reliability theory is commonly used for structural components...

  7. Tribological advancements for reliable wind turbine performance.

    Science.gov (United States)

    Kotzalas, Michael N; Doll, Gary L

    2010-10-28

    Wind turbines have had various limitations to their mechanical system reliability owing to tribological problems over the past few decades. While several studies show that turbines are becoming more reliable, it is still not at an overall acceptable level to the operators based on their current business models. Data show that the electrical components are the most problematic; however, the parts are small, thus easy and inexpensive to replace in the nacelle, on top of the tower. It is the tribological issues that receive the most attention as they have higher costs associated with repair or replacement. These include the blade pitch systems, nacelle yaw systems, main shaft bearings, gearboxes and generator bearings, which are the focus of this review paper. The major tribological issues in wind turbines and the technological developments to understand and solve them are discussed within. The study starts with an overview of fretting corrosion, rolling contact fatigue, and frictional torque of the blade pitch and nacelle yaw bearings, and references to some of the recent design approaches applied to solve them. Also included is a brief overview into lubricant contamination issues in the gearbox and electric current discharge or arcing damage of the generator bearings. The primary focus of this review is the detailed examination of main shaft spherical roller bearing micropitting and gearbox bearing scuffing, micropitting and the newer phenomenon of white-etch area flaking. The main shaft and gearbox are integrally related and are the most commonly referred to items involving expensive repair costs and downtime. As such, the latest research and developments related to the cause of the wear and damage modes and the technologies used or proposed to solve them are presented.

  8. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  9. The consequences of dependence between the formal area efficiency and the macroscopic electric field on linearity behavior in Fowler-Nordheim plots

    Science.gov (United States)

    de Assis, Thiago A.; Dall'Agnol, Fernando F.; Andrade, Roberto F. S.

    2016-09-01

    This work presents a theoretical explanation for a crossover in the linear behavior in Fowler-Nordheim (FN) plots based on orthodox cold field electron emission (CFE) experimental data. It is characterized by a clear change in the decay rate of usually single-slope FN plots, and has been reported when non-uniform nano-emitters are subject to high macroscopic electric field F M. We assume that the number of emitting spots, which defines an apparent formal area efficiency of CFE surfaces, depends on the macroscopic electric field. Non-uniformity is described by local enhancement factors ≤ft\\{{γj}\\right\\} , which are randomly assigned to each distinct emitter of a conducting CFE surface, from a discrete probability distribution ρ ≤ft({γj}\\right) , with j  =  1, 2. It is assumed that ρ ≤ft({γ1}\\right)right) , and that {γ1}>{γ2} . The local current density is evaluated by considering a usual Schottky-Nordheim barrier. The results reproduce the two distinct slope regimes in FN plots when {{F}\\text{M}}\\in [2, 20] V μm-1 and are analyzed by taking into account the apparent formal area efficiency, the distribution ρ, and the slopes in the corresponding FN plot. Finally, we remark that our results from numerical solution of Laplace’s equation, for an array of conducting nano-emitters with uniform apex radii 50 nm but different local height, supports our theoretical assumptions and could used in orthodox CFE experiments to test our predictions.

  10. Reliability Generalization: "Lapsus Linguae"

    Science.gov (United States)

    Smith, Julie M.

    2011-01-01

    This study examines the proposed Reliability Generalization (RG) method for studying reliability. RG employs the application of meta-analytic techniques similar to those used in validity generalization studies to examine reliability coefficients. This study explains why RG does not provide a proper research method for the study of reliability,…

  11. Home Electrical Safety Checklist

    Science.gov (United States)

    ... in kitchens, bathrooms, and other areas where the risk of electric shock is higher. Consider having GFCIs installed in ... life. By installing GFCIs, you are reducing your risk of electric shock. AFCIs are special circuit breakers that detect ...

  12. 关于电力系统广域保护的评述%Review on Wide Area Protection of Electric Power Systems

    Institute of Scientific and Technical Information of China (English)

    薛禹胜; 雷兴; 薛峰; 文福拴; Z. Y. Dong; G. Ledwich

    2012-01-01

    为有利于电力系统停电防御体系的进一步发展,讨论电力系统的广域保护,包括广域设备保护和广域系统保护的功能、控制方式及系统结构;回顾其信息采集、知识提取和控制决策方面的进展。从理论和应用相结合的观点剖析广域后备保护的可行性、困难和发展方向;指出需要在算法与受扰轨迹的知识提取上取得重大突破,并与数值仿真相结合,才能真正发挥相量测量单元在广域保护中的作用;强调按风险观点将广域保护与预防控制及传统保护协调的重要性。%For the further development of framework for defending blackouts,we discussed the functions,control modes and system structures of wide area protection of electric power systems,which include wide area equipment protection systems and wide area system protection systems,and reviewed recent developments in the information acquisition,knowledge extraction,and decision making of wide area protection systems.Moreover,from a viewpoint of combining both theory and application,we discussed the feasibility and further development of wide area backup protection.It is pointed out that major breakthroughs should be made in algorithms and knowledge extraction technologies from disturbed trajectories,and numerical simulations should be combined,so that the advantages of phasor measurement units can be fully utilized in wide area protection systems.It is also emphasized that wide area protection systems should be coordinated with preventive control and conventional protection from the viewpoint of risk management.

  13. Seawater intrusion mapping using electrical resistivity tomography and hydrochemical data. An application in the coastal area of eastern Thermaikos Gulf, Greece

    Energy Technology Data Exchange (ETDEWEB)

    Kazakis, N., E-mail: kazanera@yahoo.com [Aristotle University of Thessaloniki, Department of Geology, Lab. of Engineering Geology & Hydrogeology, 54124 Thessaloniki (Greece); Pavlou, A. [Aristotle University of Thessaloniki, Department of Geology, Lab. of Engineering Geology & Hydrogeology, 54124 Thessaloniki (Greece); Vargemezis, G. [Aristotle University of Thessaloniki, Department of Geology, Lab. of Applied Geophysics, 54124 Thessaloniki (Greece); Voudouris, K.S.; Soulios, G. [Aristotle University of Thessaloniki, Department of Geology, Lab. of Engineering Geology & Hydrogeology, 54124 Thessaloniki (Greece); Pliakas, F. [Democritus University of Thrace, Department of Civil Engineering, Xanthi 67100 (Greece); Tsokas, G. [Aristotle University of Thessaloniki, Department of Geology, Lab. of Applied Geophysics, 54124 Thessaloniki (Greece)

    2016-02-01

    The aim of this study was to determine the extent and geometrical characteristics of seawater intrusion in the coastal aquifer of the eastern Thermaikos Gulf, Greece. Hydrochemical data and geoelectrical measurements were combined and supplemented to determine the hydrochemical regime of the study site in regard to seawater phenomena. Chemical analysis of groundwater was performed in 126 boreholes and fifteen electrical resistivity tomographies (ERT) were measured, whereas in two sites the ERT measurements were repeated following the wet season. The Cl{sup −} concentrations recorded reached 2240 mg/L indicating seawater intrusion which was also verified by ionic ratios. The ionic ratios were overlapped and a seawater intrusion map (SWIM) was produced. A significant part of the coastal aquifer (up to 150 km{sup 2}) is influenced by seawater intrusion. The areas with the most intensive salinization are located between Nea Kallikratia–Epanomi and Aggelochori–Peraia. According to the ERTs, in the influenced areas the salinization of the aquifer exceeds 1 km toward the mainland and its depth reaches 200 m. In the area surrounding Thessaloniki airport, the ERTs revealed salinization of the upper aquifer to depths of up to 40 m, whereas the lower aquifer is uninfluenced. This abnormal distribution of seawater intrusion demonstrates the value of geoelectrical methods in the study of seawater intrusion especially in areas with limited available hydrochemical data. - Highlights: • ERTs determined the geometrical characteristics of the saline aquifer. • An abnormal distribution of seawater intrusion was recorded. • Four ionic ratios overlapped and a seawater intrusion map was produced. • Cl{sup −} concentrations increased significantly from 2005 to 2010 by up to 1800 mg/L.

  14. Reliability of lightning resistant overhead distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Tolbert, L.M.; Cleveland, J.T.; Degenhardt, L.J.

    1995-04-01

    An assessment of the 32 year historical reliability of the 13.8 kV electrical distribution system at the Oak Ridge National Laboratory (ORNL) in Tennessee has yielded several conclusions useful In the planning of Industrial power Systems. The system configuration at ORNL has essentially remained unchanged in the last 32 years which allows a meaningful comparison of reliability trends for the plant`s eight overhead distribution lines, two of which were built in the 1960`s with lightning resistant construction techniques. Meticulous records indicating the cause, duration, and location of 135 electric outages in the plant`s distribution system have allowed a reliability assessment to be performed. The assessment clearly shows how differences in voltage construction class, length, age, and maximum elevation above a reference elevation influence the reliability of overhead power distribution lines. Comparisons are also made between the ORNL historical data and predicted failure rates from ANSI and IEEE industry surveys.

  15. The Accelerator Reliability Forum

    CERN Document Server

    Lüdeke, Andreas; Giachino, R

    2014-01-01

    A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.

  16. Assuring reliability program effectiveness.

    Science.gov (United States)

    Ball, L. W.

    1973-01-01

    An attempt is made to provide simple identification and description of techniques that have proved to be most useful either in developing a new product or in improving reliability of an established product. The first reliability task is obtaining and organizing parts failure rate data. Other tasks are parts screening, tabulation of general failure rates, preventive maintenance, prediction of new product reliability, and statistical demonstration of achieved reliability. Five principal tasks for improving reliability involve the physics of failure research, derating of internal stresses, control of external stresses, functional redundancy, and failure effects control. A final task is the training and motivation of reliability specialist engineers.

  17. Reliability analysis of DOOF for Weibull distribution

    Institute of Scientific and Technical Information of China (English)

    陈文华; 崔杰; 樊晓燕; 卢献彪; 相平

    2003-01-01

    Hierarchical Bayesian method for estimating the failure probability Pi under DOOF by taking the quasi-Beta distribution B(pi-1 , 1,1, b ) as the prior distribution is proposed in this paper. The weighted Least Squares Estimate method was used to obtain the formula for computing reliability distribution parameters and estimating the reliability characteristic values under DOOF. Taking one type of aerospace electrical connectoras an example, the correctness of the above method through statistical analysis of electrical connector acceler-ated life test data was verified.

  18. Enlightenment on Computer Network Reliability From Transportation Network Reliability

    OpenAIRE

    Hu Wenjun; Zhou Xizhao

    2011-01-01

    Referring to transportation network reliability problem, five new computer network reliability definitions are proposed and discussed. They are computer network connectivity reliability, computer network time reliability, computer network capacity reliability, computer network behavior reliability and computer network potential reliability. Finally strategies are suggested to enhance network reliability.

  19. Becoming a high reliability organization.

    Science.gov (United States)

    Christianson, Marlys K; Sutcliffe, Kathleen M; Miller, Melissa A; Iwashyna, Theodore J

    2011-01-01

    Aircraft carriers, electrical power grids, and wildland firefighting, though seemingly different, are exemplars of high reliability organizations (HROs)--organizations that have the potential for catastrophic failure yet engage in nearly error-free performance. HROs commit to safety at the highest level and adopt a special approach to its pursuit. High reliability organizing has been studied and discussed for some time in other industries and is receiving increasing attention in health care, particularly in high-risk settings like the intensive care unit (ICU). The essence of high reliability organizing is a set of principles that enable organizations to focus attention on emergent problems and to deploy the right set of resources to address those problems. HROs behave in ways that sometimes seem counterintuitive--they do not try to hide failures but rather celebrate them as windows into the health of the system, they seek out problems, they avoid focusing on just one aspect of work and are able to see how all the parts of work fit together, they expect unexpected events and develop the capability to manage them, and they defer decision making to local frontline experts who are empowered to solve problems. Given the complexity of patient care in the ICU, the potential for medical error, and the particular sensitivity of critically ill patients to harm, high reliability organizing principles hold promise for improving ICU patient care.

  20. Human Reliability Program Overview

    Energy Technology Data Exchange (ETDEWEB)

    Bodin, Michael

    2012-09-25

    This presentation covers the high points of the Human Reliability Program, including certification/decertification, critical positions, due process, organizational structure, program components, personnel security, an overview of the US DOE reliability program, retirees and academia, and security program integration.

  1. Production of hydrogen driven from biomass waste to power Remote areas away from the electric grid utilizing fuel cells and internal combustion engines vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Tawfik, Hazem [Farmingdale State College, NY (United States)

    2017-03-10

    Recent concerns over the security and reliability of the world’s energy supply has caused a flux towards the research and development of renewable sources. A leading renewable source has been found in the biomass gasification of biological materials derived from organic matters such as wood chips, forest debris, and farm waste that are found in abundance in the USA. Accordingly, there is a very strong interest worldwide in the development of new technologies that provide an in-depth understanding of this economically viable energy source. This work aims to allow the coupling of biomass gasification and fuel cell systems as well as Internal Combustion Engines (ICE) to produce high-energy efficiency, clean environmental performance and near-zero greenhouse gas emissions. Biomass gasification is a process, which produces synthesis gas (syngas) that contains 19% hydrogen and 20% carbon monoxide from inexpensive organic matter waste. This project main goal is to provide cost effective energy to the public utilizing remote farms’ waste and landfill recycling area.

  2. Estimated winter 1980-1981 electric demand and supply, contiguous United States. Staff report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-12-01

    This report summarizes the most recent data available concerning projected electrical peak demands and available power resouces for the 1980-1981 winter peak period, as reported by electric utilities in the contiguous United States. The data, grouped by Regional Reliability Council areas and by Electrical Regions within the Council areas, was obtained from the Form 12E-2 reports filed by utilities with the Department of Energy on October 15, 1980 (data as of September 30). In some instances the data were revised or verified by telephone. Considerations affecting reliability, arising from Nuclear Regulatory Commission actions based on lessons learned from the forced outage of Three Mile Island Nuclear Unit No. 2, were factored into the report. No widespread large-scale reliability problems are foreseen for electric power supply this winter, on the basis of the supply and demand projections furnished by the electric utilities. Reserve margins could drop in some electric regions to levels considered inadequate for reliable service, if historical forced-outage magnitudes recur.

  3. Reliable Design Versus Trust

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth A.

    2016-01-01

    This presentation focuses on reliability and trust for the users portion of the FPGA design flow. It is assumed that the manufacturer prior to hand-off to the user tests FPGA internal components. The objective is to present the challenges of creating reliable and trusted designs. The following will be addressed: What makes a design vulnerable to functional flaws (reliability) or attackers (trust)? What are the challenges for verifying a reliable design versus a trusted design?

  4. Groundwater contamination in the basement-complex area of Ile-Ife, southwestern Nigeria: A case study using the electrical-resistivity geophysical method

    Science.gov (United States)

    Adepelumi, A. A.; Ako, B. D.; Ajayi, T. R.

    2001-11-01

    Hydrogeoenvironmental studies were carried out at the sewage-disposal site of Obafemi Awolowo University campus, Ile-Ife, Nigeria. The objective of the survey was to determine the reliability of the electrical-resistivity method in mapping pollution plumes in a bedrock environment. Fifty stations were occupied with the ABEM SAS 300C Terrameter using the Wenner array. The electrical-resistivity data were interpreted by a computer-iteration technique. Water samples were collected at a depth of 5.0 m in 20 test pits and analyzed for quality. The concentrations of Cr, Cd, Pb, Zn, and Cu are moderately above the World Health Organization recommended guidelines. Plumes of contaminated water issuing from the sewage ponds were delineated. The geoelectric sections reveal four subsurface layers, with increasing depth, lateritic clay, clayey sand/sand, and weathered/fractured bedrock, and fresh bedrock. The deepest layers, 3 and 4, constitute the main aquifer, which has a thickness of 3.1-67.1 m. The distribution of the elements in the sewage effluent confirms a hydrological communication between the disposal ponds and groundwater. The groundwater is contaminated, as shown by sampling and the geophysical results. Thus, the results demonstrate the reliability of the direct-current electrical-resistivity geophysical method in sensing and mapping pollution plumes in a crystalline bedrock environment. Résumé. Des études géo-environnementales ont été réalisées sur le site d'épandages du campus universitaire d'Obafemi Awolowo, à Ile-Ife (Nigeria). L'objectif de ce travail était de déterminer la fiabilité de la méthode des résistivités électriques pour cartographier les panaches de pollution dans un environnement de socle. Cinquante stations ont été soumises à mesures au moyen d'un ABEM SAS 300C Terrameter en utilisant le dispositif de Wenner. Les données de résistivité électrique ont été interprétées au moyen d'une technique de calcul itérative. Des

  5. Viking Lander reliability program

    Science.gov (United States)

    Pilny, M. J.

    1978-01-01

    The Viking Lander reliability program is reviewed with attention given to the development of the reliability program requirements, reliability program management, documents evaluation, failure modes evaluation, production variation control, failure reporting and correction, and the parts program. Lander hardware failures which have occurred during the mission are listed.

  6. Reliability Based Ship Structural Design

    DEFF Research Database (Denmark)

    Dogliani, M.; Østergaard, C.; Parmentier, G.;

    1996-01-01

    with developments of models of load effects and of structural collapse adopted in reliability formulations which aim at calibrating partial safety factors for ship structural design. New probabilistic models of still-water load effects are developed both for tankers and for containerships. New results are presented......This paper deals with the development of different methods that allow the reliability-based design of ship structures to be transferred from the area of research to the systematic application in current design. It summarises the achievements of a three-year collaborative research project dealing...... structure of several tankers and containerships. The results of the reliability analysis were the basis for the definition of a target safety level which was used to asses the partial safety factors suitable for in a new design rules format to be adopted in modern ship structural design. Finally...

  7. 糖尿病问题量表测评2型糖尿病患者的效度和信度%Validity and reliability of the Problem Area in Diabetes Scale in patients with type 2 diabetes

    Institute of Scientific and Technical Information of China (English)

    任洁; 洪霞; 赵维纲; 段艳平; 熊娜娜; 李涛; 赵晓晖; 史丽丽; 魏镜

    2015-01-01

    Objective:To evaluate the validity and reliability of the Problem Area in Diabetes Scale (PAID) for assessing diabetes-related distress in patients with type 2 diabetes. Methods:Totally 203 outpatients with type 2 diabetes from a tertiary hospital in Beijing were selected. They were assessed with PAID,Hamilton Depression Scale (HAMD-17),Patient Health Questionaire-9(PHQ-9),World Health Organization Five item Well-Being Index (WHO-5 ),Mini-International Neuropsychiatric Interview (MINI)and HbA1 C. Item analysis and exploratory factoranalysis were conducted to test constructive validity. Concurrent validity was evaluated by the correlation coeffi-cients with the other instruments mentioned above. Totally 3 1 subjects were retested 4 weeks later to obtain the test-retest reliability. Results:Exploratory factor analysis produced 4 factors,including emotional,therapeutic,diet and perceived society support problems specific to diabetics. The total variance contribution ratio was 64. 33%. Except i-tem 7 and 20,no item was across two factors. The correlation coefficients of each item with relevant subscale score ranged from 0. 67 to 0. 86. The PAID scores were positively correlated with the scores of HAMD-17,PHQ-9 and HbA1C (r=0. 48,0. 43,0. 21,P<0. 001 or 0. 01),and negatively correlated with WHO-5 scores (r=-0. 46,P<0. 001). The Cronbach's αcoefficients were 0. 94 for the total scale and 0. 81 -0. 88 for the 4 subscales. The test-retest reliability coefficient was 0. 65 for the total scale and 0. 53-0. 73 for the 4 subscales. Conclusion:The validi-ty and reliability of the Problem Area in Diabetes Scale are acceptable in Chinese mainland,and can be available to assess the stress related to diabetics.%目的:在2型糖尿病患者中,对糖尿病问题量表(PAID)的效度和信度进行检验,用以测量2型糖尿病患者的疾病压力问题。方法:在北京市某综合三甲医院内分泌科门诊搜集2型糖尿病患者203例。采用条目分析

  8. The precursory electric signals, observed before the Izmit Turkey EQ (Mw = 7.6, August 17th, 1999), analyzed in terms of a hypothetically pre-activated, in the focal area, large scale piezoelectric mechanism

    CERN Document Server

    Thanassoulas, C

    2011-01-01

    The generated, prior to the Izmit Turkey large EQ, preseismic electric signals were recorded in Greece by the VOL Earth's electric field monitoring site. In order to explain their peculiar character and their generating mechanism, a large scale piezoelectric mechanism was assumed that was initiated in the Izmit seismogenic region long before the EQ occurrence time. The theoretical analysis of the adopted physical model justifies the generation of a number of specific electric signals that can be emitted from the focal area before the rock formation failure. The processing of the registered by the VOL monitoring site raw data revealed the presence of similar signals as the expected theoretical ones. Therefore, it is concluded that long before the Izmit EQ occurrence a large scale piezoelectric mechanism was initiated that was modulated too by the tidally triggered lithospheric oscillation and therefore generated the observed preseismic electric signals. The adopted piezoelectric model provides critical informa...

  9. Protection of electricity distribution networks

    CERN Document Server

    Gers, Juan M

    2004-01-01

    Written by two practicing electrical engineers, this second edition of the bestselling Protection of Electricity Distribution Networks offers both practical and theoretical coverage of the technologies, from the classical electromechanical relays to the new numerical types, which protect equipment on networks and in electrical plants. A properly coordinated protection system is vital to ensure that an electricity distribution network can operate within preset requirements for safety for individual items of equipment, staff and public, and the network overall. Suitable and reliable equipment sh

  10. Effects of the drought on California electricity supply and demand

    Energy Technology Data Exchange (ETDEWEB)

    Benenson, P.; Greene, B.; Kahn, E.; Krieg, B.; Lasater, I.; Ritschard, R.; Ruderman, H.; Sathaye, J.; Sextro, R.; Siri, W.; Vincent, L.

    1977-06-01

    At the end of the driest year on record, California faces water shortages whose impacts will be felt with progressive severity through the summer and fall of 1977. Electric power is not entirely exempt from these impacts and could, if severly affected, compound the direct distresses of the drought. Each of the major California electric utility companies has forecasted the short-term effects on electricity supply and demand in its service area. The study reported here undertook an independent analysis to provide a statewide assessment of impacts and remedial actions and to develop additional analytical tools and data for these purposes. The study examined various aspects of the drought as it relates to electricity supply and demand, reliability of supply to meet summer peak loads, the efficacy of conservation measures, and probable increases in power plant emissions and cost of generating electricity. The results of the study, based in part on the 1977 electricity supply and demand projections submitted by the four utilities to the California Energy Resources Conservation and Development Commission (CERCDC), support the utilities' conclusions that the three southern California utilities have sufficient reserve capacity and fuel to meet their own needs and to assist PG and E in meeting its load demand with little loss of reliability. However, to achieve this the utilities in their submissions have had to assume: 1) full coordination among the utilities; and 2) no air pollution limitations on electricity generation in the South Coast Air Basin. 32 references.

  11. Event/Time/Availability/Reliability-Analysis Program

    Science.gov (United States)

    Viterna, L. A.; Hoffman, D. J.; Carr, Thomas

    1994-01-01

    ETARA is interactive, menu-driven program that performs simulations for analysis of reliability, availability, and maintainability. Written to evaluate performance of electrical power system of Space Station Freedom, but methodology and software applied to any system represented by block diagram. Program written in IBM APL.

  12. The inclusion of electric power and the challenge of sustainability in remote inland areas of the Amazon; A inclusao eletrica e o desafio da sustentabilidade nas areas remotas do interior da Amazonia

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcante, Andreia Santos; Cartaxo, Elizabeth Ferreira [Universidade Federal do Amazonas (NIEMA/UFAM), Manaus, AM (Brazil). Nucleo Interdisciplinar de Energia, Meio Ambiente e Agua

    2008-07-01

    This article brings some reflections on the National Program of Universalization of the Access and Use of the Electric Energy, Luz para Todos, in areas as the Amazonia. This Program when implanting and executing the actions characterized the Brazilian state in way uniform, disrespecting the particularity and diversity of the Amazon region. This attitude has not met of the goals foreseen for the electrification of the Amazonian, evidencing thus, that the geographic, cultural and social multiplicities of climates and characteristics constitute great obstacles for the implantation of homogeneous politics. This, for certain, demonstrates that the potential of development of each region has differentiated dynamic, which would have to influence and to direct the formularization of politics. It characterizes this proposal bold and ambitious of the Federal Government from carried through empirical experience in an Amazonian community, Terra Preta do Limao, located in the city of Barreirinha. In this way, given referring to the organizational structure, the situation of job and income, to the access the social goods and services and the productive occupational vocation of this population bring answers on the impacts of the program in the improvement of the quality of life of this social segment. Moreover, it presents indications of that the resources destined to the implantation of the program, make impracticable, for its high cost, other social priorities. Although the electric energy is essential for the economic progress of a country, the expansion of its services to the necessary society to be seen in accord with sustainable criteria, of form to prevent the exploration and high consumption of the natural resources and the wastefulness of energy. With this reading, the work if considers to show to the incoherencies of the Program in the State of Amazon, evidencing the obstacles for the reach of the goals traced for the State. Therefore, considering what the Amazonia

  13. Guide to Cybersecurity, Resilience, and Reliability for Small and Under-Resourced Utilities

    Energy Technology Data Exchange (ETDEWEB)

    Ingram, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Martin, Maurice [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-01-01

    Small electricity utilities -- those with less than 100 employees or 50,000 meters -- provide essential services to large parts of the United States while facing a number of challenges unique to their mission. For instance, they often serve areas that are sparsely populated, meaning that their per-customer cost to provide service is higher. At the same time, they often serve customers that have moderate or fixed incomes, meaning that they are under strong pressure to keep costs down. This pressure puts them on a strict budget and creates a need for innovative solutions to common problems. Further, their service areas may include extreme climates, making severe weather events more frequent and their aftermaths more expensive to address. This guide considers challenges that small utilities face while ensuring the reliability, resilience, and cybersecurity of their electric service; approaches to address those challenges using existing guidance documents; ways that the federal government could provide support in these areas.

  14. 76 FR 37103 - Electricity Advisory Committee

    Science.gov (United States)

    2011-06-24

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of Energy. ACTION: Notice of open meeting. SUMMARY: This notice announces a meeting of the Electricity..., Arlington, Virginia 22203. FOR FURTHER INFORMATION CONTACT: David Meyer, Office of Electricity Delivery...

  15. 75 FR 61454 - Electricity Advisory Committee

    Science.gov (United States)

    2010-10-05

    ... Electricity Advisory Committee AGENCY: Department of Energy, Office of Electricity Delivery and Energy...-established DOE Electricity Advisory Committee. The Federal Advisory Committee Act (Pub. L. 92-463, 86 Stat...: David Meyer, Designated Federal Officer, Office of Electricity Delivery and Energy Reliability,...

  16. 78 FR 77443 - Electricity Advisory Committee

    Science.gov (United States)

    2013-12-23

    ... Electricity Advisory Committee AGENCY: Office of Electricity Delivery and Energy Reliability, Department of... Electricity Advisory Committee (EAC). The Federal Advisory Committee Act (Pub. L. 92-463, 86 Stat. 770.../oe/services/electricity-advisory-committee-eac . FOR FURTHER INFORMATION CONTACT: Matthew...

  17. Reliable knowledge discovery

    CERN Document Server

    Dai, Honghua; Smirnov, Evgueni

    2012-01-01

    Reliable Knowledge Discovery focuses on theory, methods, and techniques for RKDD, a new sub-field of KDD. It studies the theory and methods to assure the reliability and trustworthiness of discovered knowledge and to maintain the stability and consistency of knowledge discovery processes. RKDD has a broad spectrum of applications, especially in critical domains like medicine, finance, and military. Reliable Knowledge Discovery also presents methods and techniques for designing robust knowledge-discovery processes. Approaches to assessing the reliability of the discovered knowledge are introduc

  18. Circuit design for reliability

    CERN Document Server

    Cao, Yu; Wirth, Gilson

    2015-01-01

    This book presents physical understanding, modeling and simulation, on-chip characterization, layout solutions, and design techniques that are effective to enhance the reliability of various circuit units.  The authors provide readers with techniques for state of the art and future technologies, ranging from technology modeling, fault detection and analysis, circuit hardening, and reliability management. Provides comprehensive review on various reliability mechanisms at sub-45nm nodes; Describes practical modeling and characterization techniques for reliability; Includes thorough presentation of robust design techniques for major VLSI design units; Promotes physical understanding with first-principle simulations.

  19. Reliability of fluid systems

    Directory of Open Access Journals (Sweden)

    Kopáček Jaroslav

    2016-01-01

    Full Text Available This paper focuses on the importance of detection reliability, especially in complex fluid systems for demanding production technology. The initial criterion for assessing the reliability is the failure of object (element, which is seen as a random variable and their data (values can be processed using by the mathematical methods of theory probability and statistics. They are defined the basic indicators of reliability and their applications in calculations of serial, parallel and backed-up systems. For illustration, there are calculation examples of indicators of reliability for various elements of the system and for the selected pneumatic circuit.

  20. Measurement System Reliability Assessment

    Directory of Open Access Journals (Sweden)

    Kłos Ryszard

    2015-06-01

    Full Text Available Decision-making in problem situations is based on up-to-date and reliable information. A great deal of information is subject to rapid changes, hence it may be outdated or manipulated and enforce erroneous decisions. It is crucial to have the possibility to assess the obtained information. In order to ensure its reliability it is best to obtain it with an own measurement process. In such a case, conducting assessment of measurement system reliability seems to be crucial. The article describes general approach to assessing reliability of measurement systems.

  1. Electric power monthly

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The Energy Information Administration (EIA) prepares the Electric Power Monthly (EPM) for a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. This publication provides monthly statistics for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. The EIA publishes statistics in the EPM on net generation by energy source, consumption, stocks, quantity, quality, and cost of fossil fuels; and capability of new generating units by company and plant. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead.

  2. 76 FR 58716 - Interpretation of Transmission Planning Reliability Standard

    Science.gov (United States)

    2011-09-22

    ... Policy Study Group, and Canadian Electricity Association), Florida Reliability Coordinating Council and... the issue's scope and assess its importance. The Trade Associations state such exchange of views among... small entities. The Small Business Administration's (SBA) Office of Size Standards develops...

  3. Enhanced Reliability of Photovoltaic Systems with Energy Storage and Controls

    Energy Technology Data Exchange (ETDEWEB)

    Manz, D.; Schelenz, O.; Chandra, R.; Bose, S.; de Rooij, M.; Bebic, J.

    2008-02-01

    This report summarizes efforts to reconfigure loads during outages to allow individual customers the opportunity to enhance the reliability of their electric service through the management of their loads, photovoltaics, and energy storage devices.

  4. Intraoperative direct electrical stimulations of central nervous system during surgery of gliomas near eloquent areas%术中直接皮质电刺激在功能区胶质瘤手术中的应用

    Institute of Scientific and Technical Information of China (English)

    王伟民; 白红民; 李天栋; 林健; 高寒; 王丽敏; 夏丽慧; 谢学敏

    2012-01-01

    precentral gyri operculum of left inferior frontal gyri, triangular part of left inferior frontal gyri, posterior part of left middle frontal gyri, and posterior part of left superior frontal gyri. Postoperative MRI showed 92 patients (58.60%) achieved total resection, 55 cases (35.03%) subtotal and 10 cases (6.37%) partial. One hundred and ten patients (70.06%) were diagnosed as having low grade glimas, including 71 cases of astrocytoma, 26 cases of oligodendroglioma, and 13 cases of mixed astro - oligodendroglioma, 47 patients (29.94%) were high grade gliomas, including 19 cases of glioblastoma, 15 cases of anaplastic astrocytoma, and 13 cases of anaplastic oligodendroglioma. After operation 53 patients (33.76%) occurred transient postoperative paralysis, 39 patients (24.84%) transient language disturbance and 4 patients (2.55%) permanent neurological deficits. Conclusion Intraoperative direct electrical stimulation is a reliable, precise and safety method for functional mapping of the eloquent areas. This technique allows us to achieve 'maximal safety resection' in glioma surgery.

  5. Solder joint technology materials, properties, and reliability

    CERN Document Server

    Tu, King-Ning

    2007-01-01

    Solder joints are ubiquitous in electronic consumer products. The European Union has a directive to ban the use of Pb-based solders in these products on July 1st, 2006. There is an urgent need for an increase in the research and development of Pb-free solders in electronic manufacturing. For example, spontaneous Sn whisker growth and electromigration induced failure in solder joints are serious issues. These reliability issues are quite complicated due to the combined effect of electrical, mechanical, chemical, and thermal forces on solder joints. To improve solder joint reliability, the science of solder joint behavior under various driving forces must be understood. In this book, the advanced materials reliability issues related to copper-tin reaction and electromigration in solder joints are emphasized and methods to prevent these reliability problems are discussed.

  6. LED system reliability

    NARCIS (Netherlands)

    Driel, W.D. van; Yuan, C.A.; Koh, S.; Zhang, G.Q.

    2011-01-01

    This paper presents our effort to predict the system reliability of Solid State Lighting (SSL) applications. A SSL system is composed of a LED engine with micro-electronic driver(s) that supplies power to the optic design. Knowledge of system level reliability is not only a challenging scientific ex

  7. Principles of Bridge Reliability

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Nowak, Andrzej S.

    The paper gives a brief introduction to the basic principles of structural reliability theory and its application to bridge engineering. Fundamental concepts like failure probability and reliability index are introduced. Ultimate as well as serviceability limit states for bridges are formulated...

  8. Improving machinery reliability

    CERN Document Server

    Bloch, Heinz P

    1998-01-01

    This totally revised, updated and expanded edition provides proven techniques and procedures that extend machinery life, reduce maintenance costs, and achieve optimum machinery reliability. This essential text clearly describes the reliability improvement and failure avoidance steps practiced by best-of-class process plants in the U.S. and Europe.

  9. Chapter 9: Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Algora, Carlos; Espinet-Gonzalez, Pilar; Vazquez, Manuel; Bosco, Nick; Miller, David; Kurtz, Sarah; Rubio, Francisca; McConnell,Robert

    2016-04-15

    This chapter describes the accumulated knowledge on CPV reliability with its fundamentals and qualification. It explains the reliability of solar cells, modules (including optics) and plants. The chapter discusses the statistical distributions, namely exponential, normal and Weibull. The reliability of solar cells includes: namely the issues in accelerated aging tests in CPV solar cells, types of failure and failures in real time operation. The chapter explores the accelerated life tests, namely qualitative life tests (mainly HALT) and quantitative accelerated life tests (QALT). It examines other well proven and experienced PV cells and/or semiconductor devices, which share similar semiconductor materials, manufacturing techniques or operating conditions, namely, III-V space solar cells and light emitting diodes (LEDs). It addresses each of the identified reliability issues and presents the current state of the art knowledge for their testing and evaluation. Finally, the chapter summarizes the CPV qualification and reliability standards.

  10. Assuring Software Reliability

    Science.gov (United States)

    2014-08-01

    Environmental Overdose Trauma Operational Mechanical Air embolism Exsanguination Electrical Hardware Infection Electric shock Biological and...Chemical Use Allergic response Underdose Delay of therapy Specific hazards include air in drug delivery line, tampering (for example, by a patient...1986) 346-356. CMU/SEI-2014-SR-008 | 14 3.2 The Power Grid Failure On August 14, 2003, approximately 50 million electricity consumers in

  11. Thermal Management of Power Electronics and Electric Motors for Electric-Drive Vehicles (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S.

    2014-09-01

    This presentation is an overview of the power electronics and electric motor thermal management and reliability activities at NREL. The focus is on activities funded by the Department of Energy Vehicle Technologies Office Advanced Power Electronics and Electric Motors Program.

  12. 78 FR 30747 - Reliability Standards for Geomagnetic Disturbances

    Science.gov (United States)

    2013-05-23

    ...-fits-all'' approach, the NOPR stated that the Oak Ridge Study identified several variables that...), Office of Electric Reliability, Division of Reliability Standards and Security, Federal Energy Regulatory.... Studies of GMD Events on the Bulk-Power System 7. The impact of GMDs on the Bulk-Power System has...

  13. "Reliability Of Fiber Optic Lans"

    Science.gov (United States)

    Code n, Michael; Scholl, Frederick; Hatfield, W. Bryan

    1987-02-01

    Fiber optic Local Area Network Systems are being used to interconnect increasing numbers of nodes. These nodes may include office computer peripherals and terminals, PBX switches, process control equipment and sensors, automated machine tools and robots, and military telemetry and communications equipment. The extensive shared base of capital resources in each system requires that the fiber optic LAN meet stringent reliability and maintainability requirements. These requirements are met by proper system design and by suitable manufacturing and quality procedures at all levels of a vertically integrated manufacturing operation. We will describe the reliability and maintainability of Codenoll's passive star based systems. These include LAN systems compatible with Ethernet (IEEE 802.3) and MAP (IEEE 802.4), and software compatible with IBM Token Ring (IEEE 802.5). No single point of failure exists in this system architecture.

  14. Equivalent reliability polynomials modeling EAS and their geometries

    Directory of Open Access Journals (Sweden)

    Hassan Zahir Abdul Haddi

    2015-07-01

    Full Text Available In this paper we shall introduce two equivalent techniques in order to evaluate reliability analysis of electrical aircrafts systems (EAS: (i graph theory technique, and (ii simplifying diffeomorphism technique. Geometric modeling of reliability models is based on algebraic hypersurfaces, whose intrinsic properties are able to select those models which are relevant for applications. The basic idea is to cover the reliability hypersurfaces by exponentially decay curves. Most of the calculations made in this paper have used Maple and Matlab software.

  15. Structural Reliability Methods

    DEFF Research Database (Denmark)

    Ditlevsen, Ove Dalager; Madsen, H. O.

    of structural reliability, including the theoretical basis for these methods. Partial safety factor codes under current practice are briefly introduced and discussed. A probabilistic code format for obtaining a formal reliability evaluation system that catches the most essential features of the nature......The structural reliability methods quantitatively treat the uncertainty of predicting the behaviour and properties of a structure given the uncertain properties of its geometry, materials, and the actions it is supposed to withstand. This book addresses the probabilistic methods for evaluation...

  16. Photovoltaic system reliability

    Energy Technology Data Exchange (ETDEWEB)

    Maish, A.B.; Atcitty, C. [Sandia National Labs., NM (United States); Greenberg, D. [Ascension Technology, Inc., Lincoln Center, MA (United States)] [and others

    1997-10-01

    This paper discusses the reliability of several photovoltaic projects including SMUD`s PV Pioneer project, various projects monitored by Ascension Technology, and the Colorado Parks project. System times-to-failure range from 1 to 16 years, and maintenance costs range from 1 to 16 cents per kilowatt-hour. Factors contributing to the reliability of these systems are discussed, and practices are recommended that can be applied to future projects. This paper also discusses the methodology used to collect and analyze PV system reliability data.

  17. Electric utilities in Illinois

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    Although the conference dealt specifically with concerns of the electric utilities in Illinois, the issues were dealt with in the national context as well. A separate abstract was prepared for each of the 5 sections of this proceeding. A total of 25 papers were presented. Section titles are: Forecasting, Planning and Siting, Reliability, Rates and Financing, and Future Developments.

  18. Local area networks and protocols of data transmission in electric power systems: current status and tendencies; Redes locales y protocolos de transmision de datos en sistemas electricos de potencia: estado actual y tendencias

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzoni, Rodolfo [TRANSBA S.A., Empresa de Transporte de Energia Electrica por Distribucion Troncal de la Provincia de Buenos Aires (Argentina); Vignoni, Roberto [Universidad Nacional de La Plata (UNLP), Ciudad de La Plata, Buenos Aires (Argentina)

    2001-07-01

    In electric power systems, overcome the stage of the remote system (SCADA) implementation, the current tendency is the automation and use of open architectures. That tendency is reflected in the use of standardized local area networks of industrial use and adoption of data transmission protocols which are based in international standards. The result is the connectivity and operationalization among the local devices and terminals usually called IED. In this document it is presented a summary of the standardized data transmission protocols, which have been used in electric power substations currently, based on a architecture which defines three layers of the OSI/ISO reference pattern. Based on the tendency increase of automation in substations, some ways of communication have been analyzed, they mean: local area networks such as the Ethernet pattern and some industrial ones and others such as Profibus and its respective implementation in electric power systems. It also is analyzed the tasks which have supported IEC and EPRI for defining a standardization and a model for the open communications in electric power substations.

  19. Technique for Measuring Hybrid Electronic Component Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Green, C.C.; Hernandez, C.L.; Hosking, F.M.; Robinson, D.; Rutherford, B.; Uribe, F.

    1999-01-01

    Materials compatibility studies of aged, engineered materials and hardware are critical to understanding and predicting component reliability, particularly for systems with extended stockpile life requirements. Nondestructive testing capabilities for component reliability would significantly enhance lifetime predictions. For example, if the detection of crack propagation through a solder joint can be demonstrated, this technique could be used to develop baseline information to statistically determine solder joint lifelengths. This report will investigate high frequency signal response techniques for nondestructively evaluating the electrical behavior of thick film hybrid transmission lines.

  20. Electric power monthly

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Sandra R.; Johnson, Melvin; McClevey, Kenneth; Calopedis, Stephen; Bolden, Deborah

    1992-05-01

    The Electric Power Monthly is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the national, Census division, and State levels for net generation, fuel consumption, fuel stocks, quantity and quality of fuel, cost of fuel, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fuel are also displayed for the North American Electric Reliability Council (NERC) regions. Additionally, statistics by company and plant are published in the EPM on capability of new plants, new generation, fuel consumption, fuel stocks, quantity and quality of fuel, and cost of fuel.

  1. A Review on the Faults of Electric Machines Used in Electric Ships

    Directory of Open Access Journals (Sweden)

    Dionysios V. Spyropoulos

    2013-01-01

    Full Text Available Electric propulsion systems are today widely applied in modern ships, including transport ships and warships. The ship of the future will be fully electric, and not only its propulsion system but also all the other services will depend on electric power. The robust and reliable operation of the ship’s power system is essential. In this work, a review on the mechanical and electrical faults of electric machines that are used in electric ships is presented.

  2. Reliable Electronic Equipment

    Directory of Open Access Journals (Sweden)

    N. A. Nayak

    1960-05-01

    Full Text Available The reliability aspect of electronic equipment's is discussed. To obtain optimum results, close cooperation between the components engineer, the design engineer and the production engineer is suggested.

  3. Quality and reliability management and its applications

    CERN Document Server

    2016-01-01

    Integrating development processes, policies, and reliability predictions from the beginning of the product development lifecycle to ensure high levels of product performance and safety, this book helps companies overcome the challenges posed by increasingly complex systems in today’s competitive marketplace.   Examining both research on and practical aspects of product quality and reliability management with an emphasis on applications, the book features contributions written by active researchers and/or experienced practitioners in the field, so as to effectively bridge the gap between theory and practice and address new research challenges in reliability and quality management in practice.    Postgraduates, researchers and practitioners in the areas of reliability engineering and management, amongst others, will find the book to offer a state-of-the-art survey of quality and reliability management and practices.

  4. Reliability-Centric High-Level Synthesis

    CERN Document Server

    Tosun, S; Arvas, E; Kandemir, M; Xie, Yuan

    2011-01-01

    Importance of addressing soft errors in both safety critical applications and commercial consumer products is increasing, mainly due to ever shrinking geometries, higher-density circuits, and employment of power-saving techniques such as voltage scaling and component shut-down. As a result, it is becoming necessary to treat reliability as a first-class citizen in system design. In particular, reliability decisions taken early in system design can have significant benefits in terms of design quality. Motivated by this observation, this paper presents a reliability-centric high-level synthesis approach that addresses the soft error problem. The proposed approach tries to maximize reliability of the design while observing the bounds on area and performance, and makes use of our reliability characterization of hardware components such as adders and multipliers. We implemented the proposed approach, performed experiments with several designs, and compared the results with those obtained by a prior proposal.

  5. On industrial application of structural reliability theory

    Energy Technology Data Exchange (ETDEWEB)

    Thoft-Christensen, P

    1998-06-01

    In this paper it is shown that modern structural reliability theory is being successfully applied to a number of different industries. This review of papers is in no way complete. In the literature there is a large number of similar applications and also application not touched on in this presentation. There has been some concern among scientists from this area that structural reliability theory is not being used by industry. It is probably correct that structural reliability theory is not being used by industry as much as it should be used. However, the work by the ESReDA Working Group clearly shows the vary wide application of structural reliability theory by many different industries. One must also have in mind that industry often is reluctant to publish data related to safety and reliability. (au) 32 refs.

  6. Distributed Energy Resources, Power Quality and Reliability - Background

    Energy Technology Data Exchange (ETDEWEB)

    Schienbein, Lawrence A.; DeSteese, John G.

    2002-01-31

    Power quality [PQ] and power reliability [PR] gained importance in the industrialized world as the pace of installation of sensitive appliances and other electrical loads by utility customers accelerated, beginning in the mid 1980s. Utility-grid-connected customers rapidly discovered that this equipment was increasingly sensitive to various abnormalities in the electricity supply.

  7. The rating reliability calculator

    Directory of Open Access Journals (Sweden)

    Solomon David J

    2004-04-01

    Full Text Available Abstract Background Rating scales form an important means of gathering evaluation data. Since important decisions are often based on these evaluations, determining the reliability of rating data can be critical. Most commonly used methods of estimating reliability require a complete set of ratings i.e. every subject being rated must be rated by each judge. Over fifty years ago Ebel described an algorithm for estimating the reliability of ratings based on incomplete data. While his article has been widely cited over the years, software based on the algorithm is not readily available. This paper describes an easy-to-use Web-based utility for estimating the reliability of ratings based on incomplete data using Ebel's algorithm. Methods The program is available public use on our server and the source code is freely available under GNU General Public License. The utility is written in PHP, a common open source imbedded scripting language. The rating data can be entered in a convenient format on the user's personal computer that the program will upload to the server for calculating the reliability and other statistics describing the ratings. Results When the program is run it displays the reliability, number of subject rated, harmonic mean number of judges rating each subject, the mean and standard deviation of the averaged ratings per subject. The program also displays the mean, standard deviation and number of ratings for each subject rated. Additionally the program will estimate the reliability of an average of a number of ratings for each subject via the Spearman-Brown prophecy formula. Conclusion This simple web-based program provides a convenient means of estimating the reliability of rating data without the need to conduct special studies in order to provide complete rating data. I would welcome other researchers revising and enhancing the program.

  8. Reliability of resistivity quantification for shallow subsurface water processes

    CERN Document Server

    Rings, Joerg; 10.1016/j.jappgeo.2009.03.008

    2009-01-01

    The reliability of surface-based electrical resistivity tomography (ERT) for quantifying resistivities for shallow subsurface water processes is analysed. A method comprising numerical simulations of water movement in soil and forward-inverse modeling of ERT surveys for two synthetic data sets is presented. Resistivity contrast, e.g. by changing water content, is shown to have large influence on the resistivity quantification. An ensemble and clustering approach is introduced in which ensembles of 50 different inversion models for one data set are created by randomly varying the parameters for a regularisation based inversion routine. The ensemble members are sorted into five clusters of similar models and the mean model for each cluster is computed. Distinguishing persisting features in the mean models from singular artifacts in individual tomograms can improve the interpretation of inversion results. Especially in the presence of large resistivity contrasts in high sensitivity areas, the quantification of r...

  9. Electric Motor Thermal Management R&D. Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, Kevin [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-04-01

    With the push to reduce component volumes, lower costs, and reduce weight without sacrificing performance or reliability, the challenges associated with thermal management increase for power electronics and electric motors. Thermal management for electric motors will become more important as the automotive industry continues the transition to more electrically dominant vehicle propulsion systems. The transition to more electrically dominant propulsion systems leads to higher-power duty cycles for electric drive systems. Thermal constraints place significant limitations on how electric motors ultimately perform, and as thermal management improves, there will be a direct trade-off between motor performance, efficiency, cost, and the sizing of electric motors to operate within the thermal constraints. The goal of this research project is to support broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management. Work in FY15 focused on two areas related to motor thermal management: passive thermal performance and active convective cooling. Passive thermal performance emphasized the thermal impact of materials and thermal interfaces among materials within an assembled motor. The research tasks supported the publication of test methods and data for thermal contact resistances and direction-dependent thermal conductivity within an electric motor. Active convective cooling focused on measuring convective heat-transfer coefficients using automatic transmission fluid (ATF). Data for average convective heat transfer coefficients for direct impingement of ATF jets was published. Also, experimental hardware for mapping local-scale and stator-scale convective heat transfer coefficients for ATF jet impingement were developed.

  10. Electric power monthly, April 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-07

    The Electric Power Monthly is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the US, Census division, and State levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions.

  11. Electric power monthly, May 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-25

    The Electric Power Monthly (EPM) is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the US, Census division, and State levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions.

  12. Sensitivity Analysis of Component Reliability

    Institute of Scientific and Technical Information of China (English)

    ZhenhuaGe

    2004-01-01

    In a system, Every component has its unique position within system and its unique failure characteristics. When a component's reliability is changed, its effect on system reliability is not equal. Component reliability sensitivity is a measure of effect on system reliability while a component's reliability is changed. In this paper, the definition and relative matrix of component reliability sensitivity is proposed, and some of their characteristics are analyzed. All these will help us to analyse or improve the system reliability.

  13. Russian electricity reform. Emerging challenges and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The Russian Government is pursuing a strategy of very high economic growth, with the objective of doubling gross domestic product in ten years. It recognises the central role the electricity sector has to play to achieve this target and has embarked on a highly ambitious program of electricity reform. If it is to succeed, the reform program will have to create market structures, market rules and a regulatory framework that will foster competitive wholesale and retail electricity markets. At the same time, it will have to deal with sensitive social issues related to tariff rebalancing and the removal of cross subsidies. Only competitive markets based on transparent prices that reflect costs can deliver the efficient, reliable and internationally competitive performance needed to meet the government's economic targets. Such markets are essential to attract new investment that will be required to ensure security of electricity supply after 2010. This book focuses on key aspects of the proposed reform that could have an important bearing on its success. It also raises concerns as to the pace of reform in related areas, such as the need for complementary reforms in the Russian natural gas sector. The IEA commends the Russian Government on its efforts to embrace this electricity reform - a key element critical to meeting the challenges ahead in terms of its economic growth and energy security. 17 figs., 10 tabs., 3 maps.

  14. Azurin for Biomolecular Electronics: a Reliability Study

    Science.gov (United States)

    Bramanti, Alessandro; Pompa, Pier Paolo; Maruccio, Giuseppe; Calabi, Franco; Arima, Valentina; Cingolani, Roberto; Corni, Stefano; Di Felice, Rosa; De Rienzo, Francesca; Rinaldi, Ross

    2005-09-01

    The metalloprotein azurin, used in biomolecular electronics, is investigated with respect to its resilience to high electric fields and ambient conditions, which are crucial reliability issues. Concerning the effect of electric fields, two models of different complexity agree indicating an unexpectedly high robustness. Experiments in device-like conditions confirm that no structural modifications occur, according to fluorescence spectra, even after a 40-min exposure to tens of MV/m. Ageing is then investigated experimentally, at ambient conditions and without field, over several days. Only a small conformational rearrangement is observed in the first tens of hours, followed by an equilibrium state.

  15. Quantitative impact of hydrothermal alteration on electrical resistivity in geothermal systems from a joint analysis of laboratory measurements and borehole data in Krafla area, N-E Iceland

    Science.gov (United States)

    Lévy, Léa; Páll Hersir, Gylfi; Flóvenz, Ólafur; Gibert, Benoit; Pézard, Philippe; Sigmundsson, Freysteinn; Briole, Pierre

    2016-04-01

    Rock permeability and fluid temperature are the two most decisive factors for a successful geothermal drilling. While those parameters are only measured from drilling, they might be estimated on the basis of their impact on electrical resistivity that might be imaged from surface soundings, for example through TEM (Transient Electro Magnetic) down to one km depth. The electrical conductivity of reservoir rocks is the sum of a volume term depending on fluid parameters and a surface term related to rock alteration. Understanding the link between electrical resistivity and geothermal key parameters requires the knowledge of hydrothermal alteration and its petrophysical signature with the Cation Exchange Capacity (CEC). Fluid-rock interactions related to hydrothermal circulation trigger the precipitation of alteration minerals, which are both witnesses of the temperature at the time of reaction and new paths for the electrical current. Alteration minerals include zeolites, smectites, chlorites, epidotes and amphiboles among which low temperatures parageneses are often the most conductive. The CEC of these mineral phases contributes to account for surface conductivity occuring at the water-rock interface. In cooling geothermal systems, these minerals constitute in petrophysical terms and from surface electrical conduction a memory of the equilibrium phase revealed from electrical probing at all scales. The qualitative impact of alteration minerals on resistivity structure has been studied over the years in the Icelandic geothermal context. In this work, the CEC impact on pore surfaces electrical conductivity is studied quantitatively at the borehole scale, where several types of volcanic rocks are mixed together, with various degrees of alteration and porosity. Five boreholes located within a few km at the Krafla volcano, Northeast Iceland, constitute the basis for this study. The deepest and reference hole, KJ-18, provides cuttings of rock and logging data down to 2215

  16. The preparation of the poly(vinyl alcohol/graphene nanocomposites with low percolation threshold and high electrical conductivity by using the large-area reduced graphene oxide sheets

    Directory of Open Access Journals (Sweden)

    Q. Fu

    2013-09-01

    Full Text Available We report a method to prepare the poly(vinyl alcohol/reduced graphene oxide (PVA/rGO nanocomposites with low percolation threshold and high electrical conductivity by using the large-area reduced graphene oxide (LrGO sheets. The large-area graphene oxide (LGO sheets are expected to overlap better with each other and form the continuous GO network in PVA matrix than small-area graphene oxide (SGO. During the thermal reduction process, the LGO sheets are easily restored and improve the electrical conductivity of nanocomposites due to their low damage level of conjugate-structure. As a result, the percolation threshold of PVA/LrGO nanocomposites is ~0.189 wt% lower than present reports (0.5~0.7 wt%. At the LrGO content of 0.7 wt%, the electrical conductivity of PVA/LrGO nanocomposites reaches 6.3•10–3 S/m. Besides that, this method only takes 15~30 min to reduce the PVA/GO nanocomposites effectively.

  17. Examine and Analysis for Reliability of Datum Points in Restraint Adjustment for GPS Control Network in Mining Area%矿区GPS网约束平差基准点可靠性检验分析

    Institute of Scientific and Technical Information of China (English)

    潘传姣; 高彩云

    2013-01-01

    分别探讨了4种对矿区GPS网约束平差基准点数据进行可靠性分析的方法,并采用它们对河南汝州矿GPS控制网起算数据进行具体分析和计算,将不合格的含有粗差的已知点剔除,确保了GPS控制测量成果的高精度和可靠性。%In this paper the four methods analyzing the reliability of datum points in restraint adjustment for GPS control network are probed into.Then the initial data compatibility of GPS control network is analyzed using the methods,and these measures eliminate known points including gross error to ensure survey precision and the reliability.

  18. Validity and reliability in qualitative researches

    OpenAIRE

    2012-01-01

    Abstract   Today science world changes sharply in a high speed. In a way that in all areas such as research methods these changes are obvious. Although concepts such as validity and reliability in Positivist methodology have been used with distinct and general rules, in post positivist period in which they have paid much more attention to qualitative research, these principles have lost their general form. In one hand some thinkers stress on applying common validity and reliability quantitati...

  19. Reliability Analysis for Electric Multiple Units Based on Fault Tree Monte Carlo Method%基于故障树—蒙特卡洛方法的动车组可靠性分析

    Institute of Scientific and Technical Information of China (English)

    胡川; 姚建伟

    2012-01-01

    建立CRH2型动车组系统及其走行子系统、牵引传动子系统、制动子系统、高压电器子系统、辅助供电子系统以及网络控制子系统的故障树,在此基础上运用蒙特卡洛方法和MATLAB软件,对动车组的可靠性进行仿真分析.结果表明:基于故障树分析的蒙特卡洛仿真方法能快速、准确地计算动车组整车的可靠性;当动车组各基本部件发生故障的概率服从指数分布时,整个动车组系统发生故障的概率也服从指数分布;动车组最重要的3个分系统依次为空气供给分系统、接地保护开关和高压设备箱分系统以及牵引传动分系统.%The fault trees of the CRH2 EMU system as well as its subsystems of running, traction drive, braking, high voltage apparatus, auxiliary power supply and network control were established. On that basis, Monte Carlo method and MATLAB software were applied to simulate and analyze the reliability of the EMU. The results indicate that, Monte Carlo simulation method which is based on fault tree analysis, can rapidly and accurately calculate the reliability of the whole EMU. If the fault probabilities of EMU various basic components obey exponential distribution, then does the fault probability of the whole EMU system. The three most important partial systems of the EMU are, in order, the air supply partial system, the grounding protection switch and high voltage equipment box partial system and traction drive partial system.

  20. Location-based reliability differentiated service for wireless sensor networks

    Institute of Scientific and Technical Information of China (English)

    Yong ZENG; Jianfeng MA

    2009-01-01

    Designing reliability differentiated services for missions with different reliability requirements has become a hot topic in wireless sensor networks. Combined with a location-based routing mechanism, a quantified model without full network topology is proposed to evaluate reliability. By introducing a virtual reference point, the data transfer is limited in a specified area. The reliability function of the area is given. A detailed analysis shows that the function increases quadratically with the distance between the source node and the reference node. A reliability differentiated service mechanism is then proposed. The simulation results show the efficiency of the proposed mechanism.

  1. A novel 2-phase reliability improvement of digital circuits

    Science.gov (United States)

    Shojaei, Maryam; Mahani, Ali

    2016-12-01

    Nowadays several methods based on modular redundancy are proposed to increase the reliability of digital circuits. Redundant fault tolerant techniques increase the consumed power and area overhead. So in this paper a two phase fault tolerant design is proposed to get the balance between reliability and area overhead. In the first phase, reliability optimization of digital circuits which utilizes the architecture with higher reliability as an objective function is considered. Then the automatic insertion of selective non-uniform redundancy is applied to improve the reliability of obtained circuit as second phase. To show the effectiveness of the proposed method, simulation results are compared with triple modular redundancy.

  2. A functional magnetic resonance imaging study of human brain in pain-related areas induced by electrical stimulation with different intensities

    Directory of Open Access Journals (Sweden)

    Yuan Wang

    2010-01-01

    Full Text Available Background: Pain-related studies have mainly been performed through traditional methods, which lack the rigorous analysis of anatomical locations. Functional magnetic resonance imaging (fMRI is a noninvasive method detecting neural activity, and has the ability to precisely locate related activations in vivo. Moreover, few studies have used painful stimulation of changed intensity to investigate relevant functioning nuclei in the human brain. Aim: This study mainly focused on the pain-related activations induced by electrical stimulation with different intensities using fMRI. Furthermore, the electrophysiological characteristics of different pain-susceptible-neurons were analyzed to construct the pain modulatory network, which was corresponding to painful stimulus of changed intensity. Materials and Methods: Twelve volunteers underwent functional scanning receiving different electrical stimulation. The data were collected and analyzed to generate the corresponding functional activation maps and response time curves related to pain. Results: The common activations were mainly located in several specific regions, including the secondary somatosensory cortex (SII, insula, anterior cingulate cortex (ACC, thalamus, and other cerebral regions. Moreover, innocuous electrical stimulation primarily activated the lateral portions of SII and thalamus, as well as the posterior insula, anterior ACC, whereas noxious electrical stimulation primarily activated the medial portions of SII and thalamus, as well as the anterior insula, the posterior ACC, with larger extensions and greater intensities. Conclusion: Several specified cerebral regions displayed different response patterns during electrical stimulation by means of fMRI, which implied that the corresponding pain-susceptible-neurons might process specific aspects of pain. Elucidation of functions on pain-related regions will help to understand the delicate pain modulation of human brain.

  3. Analysis of New Variety and Technology of Copper Clad Laminates Worldwide(Ⅶ)——Low CTE High Reliability Good Processability PCB Substrate Material R-1755V from Panasonic Electric Works%世界覆铜板新产品新技术赏析(Ⅶ)——松下电工低CTE高可靠良好加工性R-1755V

    Institute of Scientific and Technical Information of China (English)

    张家亮

    2009-01-01

    文章介绍了松下电工PCB基板材料的发展战略,综述了R-1755V的诸多性能,R-1755V具有低热膨胀、高可靠性和良好加工性,应用于网络设备、测量仪器和汽车领域.%In the paper, development stratagem of PCB substrate material of Matsushita Electric Works, Ltd. was introduced a great deal of performance included low coefficient of thermal expansion, high reliability, good PCB process of R-1755V were reviewed. R-1755V is used in network equipment, measuring instruments and automotive.

  4. THE AIRLINE'S RELIABILITY PROGRAM

    OpenAIRE

    Тамаргазін, О. А.; Національний авіаційний університет; Власенко, П. О.; Національний авіаційний університет

    2013-01-01

    Airline's operational structure for Reliability program implementation — engineering division, reliability  division, reliability control division, aircraft maintenance division, quality assurance division — was considered. Airline's Reliability program structure is shown. Using of Reliability program for reducing costs on aircraft maintenance is proposed. Рассмотрена организационная структура авиакомпании по выполнению Программы надежности - инженерный отдел, отделы по надежности авиацио...

  5. Reliability Centered Maintenance - Methodologies

    Science.gov (United States)

    Kammerer, Catherine C.

    2009-01-01

    Journal article about Reliability Centered Maintenance (RCM) methodologies used by United Space Alliance, LLC (USA) in support of the Space Shuttle Program at Kennedy Space Center. The USA Reliability Centered Maintenance program differs from traditional RCM programs because various methodologies are utilized to take advantage of their respective strengths for each application. Based on operational experience, USA has customized the traditional RCM methodology into a streamlined lean logic path and has implemented the use of statistical tools to drive the process. USA RCM has integrated many of the L6S tools into both RCM methodologies. The tools utilized in the Measure, Analyze, and Improve phases of a Lean Six Sigma project lend themselves to application in the RCM process. All USA RCM methodologies meet the requirements defined in SAE JA 1011, Evaluation Criteria for Reliability-Centered Maintenance (RCM) Processes. The proposed article explores these methodologies.

  6. Optimization of Reliability Centered Maintenance Bassed on Maintenance Costs and Reliability with Consideration of Location of Components

    Directory of Open Access Journals (Sweden)

    Mahdi Karbasian

    2011-03-01

    Full Text Available The reliability of designing systems such as electrical and electronic circuits, power generation/ distribution networks and mechanical systems, in which the failure of a component may cause the whole system failure, and even the reliability of cellular manufacturing systems that their machines are connected to as series are critically important. So far approaches for improving the reliability of these systems have been mainly based on the enhancement of inherent reliability of any system component or increasing system reliability based on maintenance strategies. Also in some of the resources, only the influence of the location of systems' components on reliability is studied. Therefore, it seems other approaches have been rarely applied. In this paper, a multi criteria model has been proposed to perform a balance among a system's reliability, location costs, and its system maintenance. Finally, a numerical example has been presented and solved by the Lingo software.

  7. High Reliability Technology of the Weld Zone of High-Frequency Electric Resistance Welding Linepipes%HFW管线钢管焊缝的高可靠性技术

    Institute of Scientific and Technical Information of China (English)

    孙宏; 王志太; 刘振伟

    2015-01-01

    为了解决HFW管线钢管焊缝可靠性问题, 通过使用高速摄像机实现了HFW焊接过程的动态可视化, 并构建了一个HFW数值分析模型, 从而优化HFW焊接条件并实现焊缝区域的均匀加热. 试验结果表明, 焊接条件优化后开发出的HFW钢管焊缝金属的夏比韧脆转变温度达到-90 ℃,且具有较高的低温吸收能量值. 此外, 开发的点融合串列束超声波检验方法实现了焊缝区氧化物的实时连续检测, 其灵敏度为常规方法的10倍以上.%To address the significant need for weld seam reliability,the HFW phenomena were visualized dynamically using a high-speed video camera,and an HFW numerical analysis model was constructed to develop optimization technology of HFW conditions and the homogeneous heating technology of the weld zone. The Charpy fracture transition temperature of the weld metal of the developed steel pipe was -90℃ showing the high absorbed energy value at cryogenic temperature. Furthermore, real-time continuous detection technology of the oxide of the weld zone was developed by a point converging tandem beam ultrasonic inspection method. This technology achieved high sensitivity 10 times or more than that of the conventional method.

  8. Gearbox Reliability Collaborative Update (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, S.; Keller, J.; Glinsky, C.

    2013-10-01

    This presentation was given at the Sandia Reliability Workshop in August 2013 and provides information on current statistics, a status update, next steps, and other reliability research and development activities related to the Gearbox Reliability Collaborative.

  9. Power Industry Reliability Coordination in Asia in a Market Environment

    Directory of Open Access Journals (Sweden)

    Nikolai I. Voropai

    2010-03-01

    Full Text Available This paper addresses the problems of power supply reliability in a market environment. The specific features of economic interrelations between the power supply organization and consumers in terms of reliability assurance are examined and the principles of providing power supply reliability are formulated. The economic mechanisms of coordinating the interests of power supply organization and consumers to provide power supply reliability are discussed. Reliability of restructuring China's power industry is introduced. Some reliability data is provided. The data shows that the reliability level has increased significantly in the past two decades. More and more measures are being applied to guarantee reliability of the restructured power systems. The reliability issues and challenges that are facing the Chinese power industry are considered The paper, then examines the evolution of power grids in India, the establishment of a regulatory framework, and operational philosophy in reliability aspects of long-, mid- as well as short-term (operational / outage planning. Grid security, restoration, and mock trial for black start, etc. from the reliability angle are considered. Related issues for islanding operation to improve service reliability for Thailand's Electric Power System are then analyzed.

  10. System Reliability Analysis: Foundations.

    Science.gov (United States)

    1982-07-01

    performance formulas for systems subject to pre- ventive maintenance are given. V * ~, , 9 D -2 SYSTEM RELIABILITY ANALYSIS: FOUNDATIONS Richard E...reliability in this case is V P{s can communicate with the terminal t = h(p) Sp2(((((p p)p) p)p)gp) + p(l -p)(((pL p)p)(p 2 JLp)) + p(l -p)((p(p p...For undirected networks, the basic reference is A. Satyanarayana and Kevin Wood (1982). For directed networks, the basic reference is Avinash

  11. Treatment of synthetic arsenate wastewater with iron-air fuel cell electrocoagulation to supply drinking water and electricity in remote areas.

    Science.gov (United States)

    Kim, Jung Hwan; Maitlo, Hubdar Ali; Park, Joo Yang

    2017-03-02

    Electrocoagulation with an iron-air fuel cell is an innovative arsenate removal system that can operate without an external electricity supply. Thus, this technology is advantageous for treating wastewater in remote regions where it is difficult to supply electricity. In this study, the possibility of real applications of this system for arsenate treatment with electricity production was verified through electrolyte effect investigations using a small-scale fuel cell and performance testing of a liter-scale fuel cell stack. The electrolyte species studied were NaCl, Na2SO4, and NaHCO3. NaCl was overall the most effective electrolyte for arsenate treatment, although Na2SO4 produced the greatest electrical current and power density. In addition, although the current density and power density were proportional to the concentrations of NaCl and Na2SO4, the use of concentrations above 20 mM of NaCl and Na2SO4 inhibited arsenate treatment due to competition effects between anions and arsenate in adsorption onto the iron hydroxide. The dominant iron hydroxide produced at the iron anode was found to be lepidocrocite by means of Raman spectroscopy. A liter-scale four-stack iron-air fuel cell with 10 mM NaCl electrolyte was found to be able to treat about 300 L of 1 ppm arsenate solution to below 10 ppb during 1 day, based on its 60-min treatment capacity, as well as produce the maximum power density of 250 mW/m(2).

  12. Evolution of electric power quality in the electricity distribution networks of Buenos Aires Metropolitan Area; La evolucion de la calidad de la energia en las redes de distribucion electrica de la zona metropolitana de Buenos Aires

    Energy Technology Data Exchange (ETDEWEB)

    Brugnoni, Mario [Universidad de Buenos Aires (Argentina). Facultad de Ingenieria. Grupo Energia y Ambiente. E-mail: mbrugno@aleph.fi.uba.ar

    1998-07-01

    The standards adopted for technical service quality in the Metropolitan Buenos Aires Concession Area and the results obtained in the application of the quality improvement during its first phase is analyzed. (author)

  13. The potential of photovoltaic systems linked to electric grid in urban areas: two cases studies; O potencial dos sistemas fotovoltaicos interligados a rede eletrica em areas urbanas: dois estudos de caso

    Energy Technology Data Exchange (ETDEWEB)

    Jardim, Carolina da Silva; Salamoni, Isabel; Ruether, Ricardo; Knob, Paulo [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Civil. Lab. de Eficiencia Energetica em Edificacoes], e-mail: carolina@labeee.ufsc.br; Diniz, Antonia Sonia Cardoso [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil)

    2004-07-01

    Since the 70s, Brazil has been facing periods of financial restrictions and crises in the national electricity sector. Strategies to control the load curve mainly at the peak hours must start to be priority in the electricity sector. One option of displacement of this load is the use of photovoltaic generators (PV) connected to the utility grid. It is observed that the peak load over the day due to air-conditioning use occurs when the solar availability is high. The load curves, for regions of 'daytime consumption', will be analyzed and compared with the capacity of PV generation. Therefore, the effective load-carrying capacity (ELCC) of PV systems connected to the utility grid will be calculated, translating the capacity of PV plants of guaranteeing the supply of the load for a specific region analyzed. The ELCC will be relevant when adequate solar radiation exists and increasing energy consumption occurs, as well as when it is necessary to expand the electrical system, mainly transmission and distribution. The analysis can be made for any region in which solar generation and power consumption data are available. The study will help to verify the efficiency of PV systems to reduce the peak load over the day. This work aims to establish a methodology of identification of regions where PV generation can be applied for maximum benefits. (author)

  14. Electricity Customers

    Science.gov (United States)

    This page discusses key sectors and how they use electricity. Residential, commercial, and industrial customers each account for roughly one-third of the nation’s electricity use. The transportation sector also accounts for a small fraction of electricity.

  15. Economic and market feasibility analysis, by the point of view of gas and electrical companies, for replacement of the electric powered showers by the natural gas powered showers in ABC Paulista area; Analise da viabilidade economica e do mercado, do ponto de vista das concessionarias de gas e de energia eletrica, pela substituicao de chuveiros eletricos por gas natural, na area do ABC paulista

    Energy Technology Data Exchange (ETDEWEB)

    Callari, Roberto [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Rosim, Sidney Olivieri [Rosim e Papaleo Consultoria e Participacoes Ltda. (Brazil)

    2008-07-01

    The possibility of an exchange of energy for heating residential water should be seen, by the point of view of the concessionaires, as a single market and exclusionary, in which the development of new customers by the concessionaire of electric energy directly involves the development of these non-customers for the distributor of natural gas. The study shows that, under the terms of concession of electricity, the loss of any part of the markets, current and expansion would be attractive only if the natural gas concessionaire could pass part of their earnings with customers users of electric showers that change their profile to the gas heaters, for electrical distribution. Under the terms of the concession to natural gas, the condition of massive investments replacement of electric showers and absorption of growth and expansion entrant with customers, increase the turnover to allow the search of a mechanism for transferring part of that revenue to absorb also customers of electricity. Thus, both the concessionaire of electricity preserve their revenue and, in turn, the concessionaire of natural gas would have an effective gain of revenue for the absorption of the customers of electric showers. (author.

  16. Avionics Design for Reliability

    Science.gov (United States)

    1976-03-01

    Consultant P.O. Box 181, Hazelwood. Missouri 63042, U.S.A. soup ""•.• • CONTENTS Page LIST OF SPEAKERS iii INTRODUCTION AND OVERVIEW-RELIABILITY UNDER... primordial , d’autant plus quo dans co cam ia procg- dure do st~lection en fiabilitg eat assez peu efficaco. La ripartition des pannes suit

  17. Parametric Mass Reliability Study

    Science.gov (United States)

    Holt, James P.

    2014-01-01

    The International Space Station (ISS) systems are designed based upon having redundant systems with replaceable orbital replacement units (ORUs). These ORUs are designed to be swapped out fairly quickly, but some are very large, and some are made up of many components. When an ORU fails, it is replaced on orbit with a spare; the failed unit is sometimes returned to Earth to be serviced and re-launched. Such a system is not feasible for a 500+ day long-duration mission beyond low Earth orbit. The components that make up these ORUs have mixed reliabilities. Components that make up the most mass-such as computer housings, pump casings, and the silicon board of PCBs-typically are the most reliable. Meanwhile components that tend to fail the earliest-such as seals or gaskets-typically have a small mass. To better understand the problem, my project is to create a parametric model that relates both the mass of ORUs to reliability, as well as the mass of ORU subcomponents to reliability.

  18. Wind Energy - How Reliable.

    Science.gov (United States)

    1980-01-01

    The reliability of a wind energy system depends on the size of the propeller and the size of the back-up energy storage. Design of the optimum system...speed incidents which generate a significant part of the wind energy . A nomogram is presented, based on some continuous wind speed measurements

  19. The reliability horizon

    CERN Document Server

    Visser, M

    1997-01-01

    The ``reliability horizon'' for semi-classical quantum gravity quantifies the extent to which we should trust semi-classical quantum gravity, and gives a handle on just where the ``Planck regime'' resides. The key obstruction to pushing semi-classical quantum gravity into the Planck regime is often the existence of large metric fluctuations, rather than a large back-reaction.

  20. The value of reliability

    DEFF Research Database (Denmark)

    Fosgerau, Mogens; Karlström, Anders

    2010-01-01

    We derive the value of reliability in the scheduling of an activity of random duration, such as travel under congested conditions. Using a simple formulation of scheduling utility, we show that the maximal expected utility is linear in the mean and standard deviation of trip duration, regardless...

  1. Reliability based structural design

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2014-01-01

    According to ISO 2394, structures shall be designed, constructed and maintained in such a way that they are suited for their use during the design working life in an economic way. To fulfil this requirement one needs insight into the risk and reliability under expected and non-expected actions. A ke

  2. Reliability based structural design

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2013-01-01

    According to ISO 2394, structures shall be designed, constructed and maintained in such a way that they are suited for their use during the design working life in an economic way. To fulfil this requirement one needs insight into the risk and reliability under expected and non-expected actions. A ke

  3. Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; Undrill, John; Mackin, Peter; Daschmans, Ron; Williams, Ben; Haney, Brian; Hunt, Randall; Ellis, Jeff; Illian, Howard; Martinez, Carlos; O' Malley, Mark; Coughlin, Katie; LaCommare, Kristina Hamachi

    2010-12-20

    An interconnected electric power system is a complex system that must be operated within a safe frequency range in order to reliably maintain the instantaneous balance between generation and load. This is accomplished by ensuring that adequate resources are available to respond to expected and unexpected imbalances and restoring frequency to its scheduled value in order to ensure uninterrupted electric service to customers. Electrical systems must be flexible enough to reliably operate under a variety of"change" scenarios. System planners and operators must understand how other parts of the system change in response to the initial change, and need tools to manage such changes to ensure reliable operation within the scheduled frequency range. This report presents a systematic approach to identifying metrics that are useful for operating and planning a reliable system with increased amounts of variable renewable generation which builds on existing industry practices for frequency control after unexpected loss of a large amount of generation. The report introduces a set of metrics or tools for measuring the adequacy of frequency response within an interconnection. Based on the concept of the frequency nadir, these metrics take advantage of new information gathering and processing capabilities that system operators are developing for wide-area situational awareness. Primary frequency response is the leading metric that will be used by this report to assess the adequacy of primary frequency control reserves necessary to ensure reliable operation. It measures what is needed to arrest frequency decline (i.e., to establish frequency nadir) at a frequency higher than the highest set point for under-frequency load shedding within an interconnection. These metrics can be used to guide the reliable operation of an interconnection under changing circumstances.

  4. Study of reliability for the electricity cogeneration and seawater desalination in the Northwest of Mexico; Estudio de factibilidad para la cogeneracion de electricidad y desalacion de agua de mar en el noroeste de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez U, G. O.; Ortega C, R. F. [UNAM, Instituto de Ingenieria, 04510 Mexico D.F. (Mexico)]. email: exergiovanni@gmail.com

    2008-07-01

    part. They were costs very competitive of 0.038-0.044 $/ kWh for the production of electric energy and of 0.60 at 0.77 $/ m{sup 3} for the produced water, with a lost of power in the generation of among 28 to 43 MW{sub e}. (Author)

  5. Development of monopoly abuse supervision of electricity rates. Entwicklung der kartellrechtlichen Missbrauchsaufsicht ueber die Strompreise

    Energy Technology Data Exchange (ETDEWEB)

    Ebel, H.R.

    1993-03-15

    Starting point for the investigation is the decision of the regional cartel office of Berlin with which it dismissed a case about a complaint against excessive electricity rates of the EBAG in East Berlin. The Berlin cartel office stated as reason for the decision that the results for 1991 of the regional electric utilities in the new Federal states, particularly also in the area of Berlin, were negative. Due to increases in cost and charges due to high capital investments also for the current year losses are expected. There is reason to believe that the prices of most electric utilities are not sufficiently calculated on the basis of costs. The rates of the electric utilities which are obviously based on average electricity rates in West Germany do not present a suitable and sufficiently reliable comparative basis for the determination of a fair price within the scope of concept of comparable market. (orig./UA)

  6. D5.3 Reading reliability report

    DEFF Research Database (Denmark)

    Cetin, Bilge Kartal; Galiotto, Carlo; Cetin, Kamil

    2010-01-01

    This deliverable presents a detailed description of the main causes of reading reliability degradation. Two main groups of impairments are recognized: those at the physical layer (e.g., fading, multipath, electromagnetic interference, shadowing due to obstacles, tag orientation misalignment, tag...... reliability. Performance metrics and methodologies for assessing reading reliability are further discussed. This document also presents a review of state-of-the-art RFID reading reliability improvement schemes. The solutions are classified into physical- (PHY), medium access control- (MAC), upper-, and cross......-layer. An additional category is created for a set of implementation guidelines and practical solutions for current RFID deployments, e.g. using multiple tags per object, multiple interrogators per area and cache memories in readers. Among physical layer solutions we find multiple antenna transceivers, novel tag...

  7. Reliable Designing of Stand-alone PV/FC Hybrid System

    Directory of Open Access Journals (Sweden)

    Saber Arabi Nowdeh

    2013-06-01

    Full Text Available Application of renewable energy sources has shown a perfect potential as a form of contribution to conventional power generation systems. This paper presents a hybrid system based on photovoltaic (PV module and PEM (proton exchange membrane fuel cell (FC with the aim of selling electricity to distribution network (DN and improving its reliability. In this paper, moreover supplying the load electricity of system, the proposed hybrid system is capable to sale electricity to DN and by electricity injection causes DN reliability improvement. The revenue from selling electricity to DN is considered as the system profit (SP. An optimization is applied to maximize the SP using GAMS environment. This study claims that moreover load electricity provision, electricity can also be sold to DN by proposed hybrid system and reliability of DN in load supplement can be increased by injecting the electricity to it.

  8. Reliability in the utility computing era: Towards reliable Fog computing

    DEFF Research Database (Denmark)

    Madsen, Henrik; Burtschy, Bernard; Albeanu, G.

    2013-01-01

    This paper considers current paradigms in computing and outlines the most important aspects concerning their reliability. The Fog computing paradigm as a non-trivial extension of the Cloud is considered and the reliability of the networks of smart devices are discussed. Combining the reliability...... requirements of grid and cloud paradigms with the reliability requirements of networks of sensor and actuators it follows that designing a reliable Fog computing platform is feasible....

  9. Electric power monthly, August 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-13

    The Electric Power Monthly (EPM) presents monthly electricity statistics. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead. The EPM is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the US, Census division, and State levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions.

  10. Electric power monthly, September 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-17

    The Electric Power Monthly (EPM) presents monthly electricity statistics. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead. The EPM is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the US, Census division, and State levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions.

  11. Spatial electric load forecasting

    CERN Document Server

    Willis, H Lee

    2002-01-01

    Spatial Electric Load Forecasting Consumer Demand for Power and ReliabilityCoincidence and Load BehaviorLoad Curve and End-Use ModelingWeather and Electric LoadWeather Design Criteria and Forecast NormalizationSpatial Load Growth BehaviorSpatial Forecast Accuracy and Error MeasuresTrending MethodsSimulation Method: Basic ConceptsA Detailed Look at the Simulation MethodBasics of Computerized SimulationAnalytical Building Blocks for Spatial SimulationAdvanced Elements of Computerized SimulationHybrid Trending-Simulation MethodsAdvanced

  12. Human Reliability Program Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Landers, John; Rogers, Erin; Gerke, Gretchen

    2014-05-18

    A Human Reliability Program (HRP) is designed to protect national security as well as worker and public safety by continuously evaluating the reliability of those who have access to sensitive materials, facilities, and programs. Some elements of a site HRP include systematic (1) supervisory reviews, (2) medical and psychological assessments, (3) management evaluations, (4) personnel security reviews, and (4) training of HRP staff and critical positions. Over the years of implementing an HRP, the Department of Energy (DOE) has faced various challenges and overcome obstacles. During this 4-day activity, participants will examine programs that mitigate threats to nuclear security and the insider threat to include HRP, Nuclear Security Culture (NSC) Enhancement, and Employee Assistance Programs. The focus will be to develop an understanding of the need for a systematic HRP and to discuss challenges and best practices associated with mitigating the insider threat.

  13. Improving Power Converter Reliability

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental...... is measured in a wind power converter at a low fundamental frequency. To illustrate more, the test method as well as the performance of the measurement circuit are also presented. This measurement is also useful to indicate failure mechanisms such as bond wire lift-off and solder layer degradation...

  14. Reliability and construction control

    Directory of Open Access Journals (Sweden)

    Sherif S. AbdelSalam

    2016-06-01

    Full Text Available The goal of this study was to determine the most reliable and efficient combination of design and construction methods required for vibro piles. For a wide range of static and dynamic formulas, the reliability-based resistance factors were calculated using EGYPT database, which houses load test results for 318 piles. The analysis was extended to introduce a construction control factor that determines the variation between the pile nominal capacities calculated using static versus dynamic formulae. From the major outcomes, the lowest coefficient of variation is associated with Davisson’s criterion, and the resistance factors calculated for the AASHTO method are relatively high compared with other methods. Additionally, the CPT-Nottingham and Schmertmann method provided the most economic design. Recommendations related to a pile construction control factor were also presented, and it was found that utilizing the factor can significantly reduce variations between calculated and actual capacities.

  15. Accelerator reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, L.; Duru, Ph.; Koch, J.M.; Revol, J.L.; Van Vaerenbergh, P.; Volpe, A.M.; Clugnet, K.; Dely, A.; Goodhew, D

    2002-07-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop.

  16. Power electronics reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Kaplar, Robert James; Brock, Reinhard C.; Marinella, Matthew; King, Michael Patrick; Stanley, James K.; Smith, Mark A.; Atcitty, Stanley

    2010-10-01

    The project's goals are: (1) use experiments and modeling to investigate and characterize stress-related failure modes of post-silicon power electronic (PE) devices such as silicon carbide (SiC) and gallium nitride (GaN) switches; and (2) seek opportunities for condition monitoring (CM) and prognostics and health management (PHM) to further enhance the reliability of power electronics devices and equipment. CM - detect anomalies and diagnose problems that require maintenance. PHM - track damage growth, predict time to failure, and manage subsequent maintenance and operations in such a way to optimize overall system utility against cost. The benefits of CM/PHM are: (1) operate power conversion systems in ways that will preclude predicted failures; (2) reduce unscheduled downtime and thereby reduce costs; and (3) pioneering reliability in SiC and GaN.

  17. Computational methods of Gaussian Particle Swarm Optimization (GPSO) and Lagrange Multiplier on economic dispatch issues (case study on electrical system of Java-Bali IV area)

    Science.gov (United States)

    Komsiyah, S.

    2014-03-01

    The objective in this paper is about economic dispatch problem of electric power generation where scheduling the committed generating units outputs so as to meet the required load demand at minimum operating cost, while satisfying all units and system equality and inequality constraint. In the operating of electric power system, an economic planning problem is one of variables that its must be considered since economically planning will give more efficiency in operational cost. In this paper the economic dispatch problem which has non linear cost function solved by using swarm intelligent method is Gaussian Particle Swarm Optimization (GPSO) and Lagrange Multiplier. GPSO is a population-based stochastic algorithms which their moving inspired by swarm intelligent and probabilities theories. To analize its accuracy, the economic dispatch solution by GPSO method will be compared with Lagrange multiplier method. From the running test result the GPSO method give economically planning calculation which it better than Lagrange multiplier method and the GPSO method faster to getting error convergence. Therefore the GPSO method have better performance to getting global best solution than the Lagrange method.

  18. Reliability of Circumplex Axes

    Directory of Open Access Journals (Sweden)

    Micha Strack

    2013-06-01

    Full Text Available We present a confirmatory factor analysis (CFA procedure for computing the reliability of circumplex axes. The tau-equivalent CFA variance decomposition model estimates five variance components: general factor, axes, scale-specificity, block-specificity, and item-specificity. Only the axes variance component is used for reliability estimation. We apply the model to six circumplex types and 13 instruments assessing interpersonal and motivational constructs—Interpersonal Adjective List (IAL, Interpersonal Adjective Scales (revised; IAS-R, Inventory of Interpersonal Problems (IIP, Impact Messages Inventory (IMI, Circumplex Scales of Interpersonal Values (CSIV, Support Action Scale Circumplex (SAS-C, Interaction Problems With Animals (IPI-A, Team Role Circle (TRC, Competing Values Leadership Instrument (CV-LI, Love Styles, Organizational Culture Assessment Instrument (OCAI, Customer Orientation Circle (COC, and System for Multi-Level Observation of Groups (behavioral adjectives; SYMLOG—in 17 German-speaking samples (29 subsamples, grouped by self-report, other report, and metaperception assessments. The general factor accounted for a proportion ranging from 1% to 48% of the item variance, the axes component for 2% to 30%; and scale specificity for 1% to 28%, respectively. Reliability estimates varied considerably from .13 to .92. An application of the Nunnally and Bernstein formula proposed by Markey, Markey, and Tinsley overestimated axes reliabilities in cases of large-scale specificities but otherwise works effectively. Contemporary circumplex evaluations such as Tracey’s RANDALL are sensitive to the ratio of the axes and scale-specificity components. In contrast, the proposed model isolates both components.

  19. ATLAS reliability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bartsch, R.R.

    1995-09-01

    Key elements of the 36 MJ ATLAS capacitor bank have been evaluated for individual probabilities of failure. These have been combined to estimate system reliability which is to be greater than 95% on each experimental shot. This analysis utilizes Weibull or Weibull-like distributions with increasing probability of failure with the number of shots. For transmission line insulation, a minimum thickness is obtained and for the railgaps, a method for obtaining a maintenance interval from forthcoming life tests is suggested.

  20. Paths to bioenergy villages. A guideline for a independent supply of heat and electricity based on biomass in rural area. 3. ed.; Wege zum Bioenergiedorf. Leitfaden fuer eine eigenstaendige Waerme- und Stromversrogung auf Basis von Biomasse im laendlichen Raum

    Energy Technology Data Exchange (ETDEWEB)

    Ruppert, Hans; Eigner-Thiel, Swantje; Girschner, Walter; Karpenstein-Machan, Marianne; Roland, Folker; Ruwisch, Volker; Sauer, Benedikt; Schmuck, Peter

    2010-12-15

    Bioenergy villages are one component for the sustainable energy supply in rural areas. The guideline under consideration is intended to encourage people in villages to switch their heat supply and electricity supply on the bases of biomass. The focus of this process-oriented guideline is on: (1) A presentation of the social feasibility, especially the involvement, motivation and encouragement of the population; (2) The presentation of concepts for a nature-friendly cultivation of the required biomass; (3) The treatment of economic and legal issues from the perspective of the people involved.

  1. Performance and Reliability of Interface Materials for Automotive Power Electronics (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S.; DeVoto, D.; Mihalic, M.; Paret, P.

    2013-07-01

    Thermal management and reliability are important because excessive temperature can degrade the performance, life, and reliability of power electronics and electric motors. Advanced thermal management technologies enable keeping temperature within limits; higher power densities; and lower cost materials, configurations and systems. Thermal interface materials, bonded interface materials and the reliability of bonded interfaces are discussed in this presentation.

  2. 75 FR 39244 - Reliability Standards Development and NERC and Regional Entity Enforcement; Further Notice...

    Science.gov (United States)

    2010-07-08

    ... Energy Regulatory Commission Reliability Standards Development and NERC and Regional Entity Enforcement... pertaining to the development of mandatory Reliability Standards for the Bulk-Power System by the North American Electric Reliability Corporation and the Regional Entities as previously announced.\\1\\ \\1\\...

  3. Electric vehicle - near or far

    Energy Technology Data Exchange (ETDEWEB)

    Laiho, Y.

    1997-11-01

    Traffic is rapidly becoming the number one environmental problem, especially in metropolitan areas. Electric vehicles have many important advantages to offer. Air quality would be improved, since electric vehicles do not pollute the environment. The improvement obtained might be equated with that resulting from the introduction of district heat for the heating of residential buildings. Electric vehicles also present considerable potential for energy conservation

  4. Comprehensive dictionary of electrical engineering

    CERN Document Server

    Laplante, Philip A

    1998-01-01

    The Comprehensive Dictionary of Electrical Engineering is a complete lexicon covering all the fields of electrical engineering.Areas examined include:applied electrical engineeringmicrowave engineeringcontrol engineeringpower engineeringdigital systems engineeringdevice electronicsand much more! The book provides workable definitions for practicing engineers, serves as a reference and research tool for students, and offers practical information for scientists and engineers in other disciplines.

  5. Updating piping reliability with field performance observations

    NARCIS (Netherlands)

    Schweckendiek, T.; Vrouwenvelder, A.C.W.M.; Calle, E.O.F.

    2014-01-01

    Flood defenses are crucial elements in flood risk mitigation in developed countries, especially in deltaic areas. In the Netherlands, the VNK2 project is currently analyzing the reliability of all primary flood defenses as part of a nationwide flood risk analysis. In this project, as in most other r

  6. On Industrial Application of Structural Reliability Theory

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    For the last two decades we have seen an increasing interest in applying structural reliability theory to many different industries. However, the number of real applications is much smaller than what one would expect. At the beginning most applications were in the design/analyses area especially...

  7. Structural Probability Concepts Adapted to Electrical Engineering

    Science.gov (United States)

    Steinberg, Eric P.; Chamis, Christos C.

    1994-01-01

    Through the use of equivalent variable analogies, the authors demonstrate how an electrical subsystem can be modeled by an equivalent structural subsystem. This allows the electrical subsystem to be probabilistically analyzed by using available structural reliability computer codes such as NESSUS. With the ability to analyze the electrical subsystem probabilistically, we can evaluate the reliability of systems that include both structural and electrical subsystems. Common examples of such systems are a structural subsystem integrated with a health-monitoring subsystem, and smart structures. Since these systems have electrical subsystems that directly affect the operation of the overall system, probabilistically analyzing them could lead to improved reliability and reduced costs. The direct effect of the electrical subsystem on the structural subsystem is of secondary order and is not considered in the scope of this work.

  8. Avaliação de pós-graduação com método ELECTRE TRI: o caso de engenharias III da capes Postgraduate evaluation through ELECTRE TRI method: the case of III engineering area of capes

    Directory of Open Access Journals (Sweden)

    Caroline Maria Guerra de Miranda

    2003-01-01

    Full Text Available Este trabalho tem como objetivo avaliar o uso de métodos de apoio à decisão multicritério para avaliação de programas de pós-graduação. Este estudo se concentra no caso particular da área Engenharias III da CAPES, para a classificação dos programas em cinco categorias (conceitos de 1 a 5. O método ELECTRE TRI foi aplicado aos dados coletados pela CAPES no triênio 1998-2000, considerando o contexto e procedimentos adotados para a área Engenharias III. Esta avaliação visa analisar a estrutura metodológica do ELECTRE TRI na classificação dos programas de pós-graduação, no período citado, propondo uma forma alternativa de tratar o problema.This work deals with the model building of multicriteria decision aid in order to evaluate the postgraduate courses in Brazil. A study case is concentrated in a particular committee of CAPES, so called the III Engineering area. These models are based on the evaluation methodology adopted by the CAPES. This methodology has the objective of making comparative analysis of the postgraduate programs of the III Engineering area during 1998-2000 term. This analysis has been conducted supported by ELECTRE TRI method, incorporating criteria utilised by the Capes in order to generate a postgraduate programmes sorting.

  9. Vertical Electrical Sounding Investigation for Delineation of Geoelectric Layers and Evaluation of Groundwater Potential in Ajagba, Asa and Ikonifin Localities of Ola Oluwa Local Government Area of Osun State, South Western Nigeria

    Directory of Open Access Journals (Sweden)

    M. Onimisi

    2013-10-01

    Full Text Available Vertical Electrical Sounding (VES surveys were carried out at Ajagba, Asa and Ikonifin communities in the north of Ola Oluwa local government area of Osun state, Nigeria in order to delineate the geoelectric layers in the area as well as evaluate the groundwater potential. The area is in the basement complex terrain of Nigeria where the occurrence of groundwater is highly unpredictable and hence requires the use of hydrologic, geophysical and geologic surveys to achieve success in groundwater development programs. The survey delineated a maximum of four geoelectric layers which may be interpreted to correspond to four geologic layers viz the topsoil, weathered basement, partly weathered/fractured basement and the fresh basement. The weathered basement and the partly weathered/fractured basement layers constitute the aquifer units. The partly weathered/fractured layer is significant in enhancing the ground water potential in this area because of its relatively low resistivity resulting from its high fracture frequency. The ground water potential in the area varies from medium to high. Groundwater development is therefore feasible in these communities.

  10. Materials and Reliability Handbook for Semiconductor Optical and Electron Devices

    CERN Document Server

    Pearton, Stephen

    2013-01-01

    Materials and Reliability Handbook for Semiconductor Optical and Electron Devices provides comprehensive coverage of reliability procedures and approaches for electron and photonic devices. These include lasers and high speed electronics used in cell phones, satellites, data transmission systems and displays. Lifetime predictions for compound semiconductor devices are notoriously inaccurate due to the absence of standard protocols. Manufacturers have relied on extrapolation back to room temperature of accelerated testing at elevated temperature. This technique fails for scaled, high current density devices. Device failure is driven by electric field or current mechanisms or low activation energy processes that are masked by other mechanisms at high temperature. The Handbook addresses reliability engineering for III-V devices, including materials and electrical characterization, reliability testing, and electronic characterization. These are used to develop new simulation technologies for device operation and ...

  11. NASA Electric Propulsion System Studies

    Science.gov (United States)

    Felder, James L.

    2015-01-01

    An overview of NASA efforts in the area of hybrid electric and turboelectric propulsion in large transport. This overview includes a list of reasons why we are looking at transmitting some or all of the propulsive power for the aircraft electrically, a list of the different types of hybrid-turbo electric propulsion systems, and the results of 4 aircraft studies that examined different types of hybrid-turbo electric propulsion systems.

  12. Ultimately Reliable Pyrotechnic Systems

    Science.gov (United States)

    Scott, John H.; Hinkel, Todd

    2015-01-01

    This paper presents the methods by which NASA has designed, built, tested, and certified pyrotechnic devices for high reliability operation in extreme environments and illustrates the potential applications in the oil and gas industry. NASA's extremely successful application of pyrotechnics is built upon documented procedures and test methods that have been maintained and developed since the Apollo Program. Standards are managed and rigorously enforced for performance margins, redundancy, lot sampling, and personnel safety. The pyrotechnics utilized in spacecraft include such devices as small initiators and detonators with the power of a shotgun shell, detonating cord systems for explosive energy transfer across many feet, precision linear shaped charges for breaking structural membranes, and booster charges to actuate valves and pistons. NASA's pyrotechnics program is one of the more successful in the history of Human Spaceflight. No pyrotechnic device developed in accordance with NASA's Human Spaceflight standards has ever failed in flight use. NASA's pyrotechnic initiators work reliably in temperatures as low as -420 F. Each of the 135 Space Shuttle flights fired 102 of these initiators, some setting off multiple pyrotechnic devices, with never a failure. The recent landing on Mars of the Opportunity rover fired 174 of NASA's pyrotechnic initiators to complete the famous '7 minutes of terror.' Even after traveling through extreme radiation and thermal environments on the way to Mars, every one of them worked. These initiators have fired on the surface of Titan. NASA's design controls, procedures, and processes produce the most reliable pyrotechnics in the world. Application of pyrotechnics designed and procured in this manner could enable the energy industry's emergency equipment, such as shutoff valves and deep-sea blowout preventers, to be left in place for years in extreme environments and still be relied upon to function when needed, thus greatly enhancing

  13. CR reliability testing

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Rill, Lynn; Frost, Meryll M.; Staab, Edward V.

    1998-07-01

    The purpose of this work was to develop a method for systematically testing the reliability of a CR system under realistic daily loads in a non-clinical environment prior to its clinical adoption. Once digital imaging replaces film, it will be very difficult to revert back should the digital system become unreliable. Prior to the beginning of the test, a formal evaluation was performed to set the benchmarks for performance and functionality. A formal protocol was established that included all the 62 imaging plates in the inventory for each 24-hour period in the study. Imaging plates were exposed using different combinations of collimation, orientation, and SID. Anthropomorphic phantoms were used to acquire images of different sizes. Each combination was chosen randomly to simulate the differences that could occur in clinical practice. The tests were performed over a wide range of times with batches of plates processed to simulate the temporal constraints required by the nature of portable radiographs taken in the Intensive Care Unit (ICU). Current patient demographics were used for the test studies so automatic routing algorithms could be tested. During the test, only three minor reliability problems occurred, two of which were not directly related to the CR unit. One plate was discovered to cause a segmentation error that essentially reduced the image to only black and white with no gray levels. This plate was removed from the inventory to be replaced. Another problem was a PACS routing problem that occurred when the DICOM server with which the CR was communicating had a problem with disk space. The final problem was a network printing failure to the laser cameras. Although the units passed the reliability test, problems with interfacing to workstations were discovered. The two issues that were identified were the interpretation of what constitutes a study for CR and the construction of the look-up table for a proper gray scale display.

  14. Blade reliability collaborative :

    Energy Technology Data Exchange (ETDEWEB)

    Ashwill, Thomas D.; Ogilvie, Alistair B.; Paquette, Joshua A.

    2013-04-01

    The Blade Reliability Collaborative (BRC) was started by the Wind Energy Technologies Department of Sandia National Laboratories and DOE in 2010 with the goal of gaining insight into planned and unplanned O&M issues associated with wind turbine blades. A significant part of BRC is the Blade Defect, Damage and Repair Survey task, which will gather data from blade manufacturers, service companies, operators and prior studies to determine details about the largest sources of blade unreliability. This report summarizes the initial findings from this work.

  15. Ferrite logic reliability study

    Science.gov (United States)

    Baer, J. A.; Clark, C. B.

    1973-01-01

    Development and use of digital circuits called all-magnetic logic are reported. In these circuits the magnetic elements and their windings comprise the active circuit devices in the logic portion of a system. The ferrite logic device belongs to the all-magnetic class of logic circuits. The FLO device is novel in that it makes use of a dual or bimaterial ferrite composition in one physical ceramic body. This bimaterial feature, coupled with its potential for relatively high speed operation, makes it attractive for high reliability applications. (Maximum speed of operation approximately 50 kHz.)

  16. Seismicity observed, at Methoni seismogenic area, Greece, after the analysis of the recorded Earth_s electric field of 21/2/2008_ 22/2/2008, at PYR, ATH and HIO monitoring sites, Greece

    CERN Document Server

    Thanassoulas, Constantine

    2008-01-01

    The seismicity, which took place at the Methoni seismogenic area, in the time period of 20/2/2008 - 10/4/2008, is analyzed in terms of its location, time of occurrence and magnitude. Furthermore, it is compared to the tidal (T=14 days, T=1 day) lithospheric oscillation and to the epicentral area suggested by the analysis of the Earth_s electric field registered on 21-22/2/2008 by PYR, ATH and HIO monitoring sites. Moreover, a comparison is made between the actual seismic energy released, during the same time period (20/2/2008 - 10/4/2008) in this specific seismogenic region and the suggested one by the probabilistic single seismic event suggested that could occur in the time period of 28/2_ 1/3/2008. The overall analysis of the Methoni seismic event reveals the validity of the used physical models: of the lithospheric oscillation, of the lithospheric seismic energy release and the one of the homogeneous Earth used for the azimuthal intensity vector analysis of the preseismic electric signals (Thanassoulas, 20...

  17. A novel electric power quality monitoring system for transient analysis

    OpenAIRE

    2014-01-01

    Electricity is vital for our daily life in modern cites. In order to ensure its reliability and supply, an electric power monitoring system is indispensable in an electric power system. Currently, most electric power monitoring systems are designed for steady-state monitoring only. They may not be able to monitor instantaneous power disturbances, such as voltage surge, happened in electric power systems. In fact, instantaneous power disturbances are frequently found in electric power systems,...

  18. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  19. 77 FR 20374 - Application To Export Electric Energy; WSPP Inc.

    Science.gov (United States)

    2012-04-04

    ... Application To Export Electric Energy; WSPP Inc. AGENCY: Office of Electricity Delivery and Energy Reliability... members, to renew the authority of those members to transmit electric energy from the United States to... new export authority for two other members to transmit electric energy from the United States...

  20. 76 FR 23470 - Version One Regional Reliability Standard for Transmission Operations

    Science.gov (United States)

    2011-04-27

    ... considering risk to the bulk electric system, there is no substantial difference between thermally-limited and..., or could place the bulk electric system at an unacceptable risk of instability, separation, or... Reliability Standard TOP-007-WECC-1 (System Operating Limits) developed by the Western Electric...

  1. Electric power monthly, April 1994

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The Electric Power Monthly (EPM) presents monthly electricity statistics. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead. This publication provides monthly statistics at the U.S., Census division, and State levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. This April 1994 issue contains 1993 year-end data and data through January 1994.

  2. Design and application of electrical fire monitoring system in mining industry

    Institute of Scientific and Technical Information of China (English)

    Diao Jinxia; Zhang Guilin; Hu Haidong; Zou Zhihui; Zhang Baojin

    2015-01-01

    To protect mining areas from electrical fire, it is very important to install electrical fire monitoring system to ensure safety in development of mineral resources and for buildings. In this paper, design for electrical fire monitoring and detection system with optional sensor modules has been proposed. In addition, necessity and suitability of electrical fire monitoring and detection system with optional sensor modules in mining areas have been reviewed. The designed electrical fire monitoring and detection system suit-able for work environment of mining industry is composed by host-computer monitoring software and slave-computer detectors. Monitoring detectors are manufactured by using embedded technology. Exter-nal shells deployed have superior enclosure performances and explosion-proof properties. It is easy to install and maintain the system. In general, the system has reached, or even exceeded standards specified in national standards for performances and appearances of such devices. Test results show application of electrical fire monitoring and detection system can effectively enhance monitoring intensity over the mining areas and provide reliable guarantee to ensure orderly development of mineral resources and to protect physical and property safety of citizens in these areas.

  3. Supply chain reliability modelling

    Directory of Open Access Journals (Sweden)

    Eugen Zaitsev

    2012-03-01

    Full Text Available Background: Today it is virtually impossible to operate alone on the international level in the logistics business. This promotes the establishment and development of new integrated business entities - logistic operators. However, such cooperation within a supply chain creates also many problems related to the supply chain reliability as well as the optimization of the supplies planning. The aim of this paper was to develop and formulate the mathematical model and algorithms to find the optimum plan of supplies by using economic criterion and the model for the probability evaluating of non-failure operation of supply chain. Methods: The mathematical model and algorithms to find the optimum plan of supplies were developed and formulated by using economic criterion and the model for the probability evaluating of non-failure operation of supply chain. Results and conclusions: The problem of ensuring failure-free performance of goods supply channel analyzed in the paper is characteristic of distributed network systems that make active use of business process outsourcing technologies. The complex planning problem occurring in such systems that requires taking into account the consumer's requirements for failure-free performance in terms of supply volumes and correctness can be reduced to a relatively simple linear programming problem through logical analysis of the structures. The sequence of the operations, which should be taken into account during the process of the supply planning with the supplier's functional reliability, was presented.

  4. Electrical safety during transplantation.

    Science.gov (United States)

    Amicucci, G L; Di Lollo, L; Fiamingo, F; Mazzocchi, V; Platania, G; Ranieri, D; Razzano, R; Camin, G; Sebastiani, G; Gentile, P

    2010-01-01

    Technologic innovations enable management of medical equipment and power supply systems, with improvements that can affect the technical aspects, economics, and quality of medical service. Herein are outlined some technical guidelines, proposed by Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, for increasing the effectiveness of the power supply system and the safety of patients and surgeons in the operating room, with particular focus on transplantation. The dependence of diagnoses and therapies on operation of the electrical equipment can potentially cause great risk to patients. Moreover, it is possible that faulty electrical equipment could produce current that may flow through the patient. Because patients are particularly vulnerable when their natural protection is considerably decreased, as during transplantation or other surgery, power supply systems must operate with a high degree of reliability and quality to prevent risk, and must be designed to reduce hazards from direct and indirect contact. Reliability of the power supply system is closely related to the quality of the project, choice of materials, and management of the system (eg, quality and frequency of servicing). Among the proposed guidelines, other than normal referencing, are (1) adoption of a monitoring system to improve the quality of the electrical parameters in the operating room, (2) institution of emergency procedures for management of electrical faults, (3) a procedure for management of fires in the operating room, (4) and maintenance interventions and inspections of medical devices to maintain minimal requirements of safety and performance.

  5. A Comparative Study of the Application of FACTS Devices in Wind Power Plants of the Southeast Area of the Mexican Electric System

    Energy Technology Data Exchange (ETDEWEB)

    Beltran-Valle, Omar; Pena-Gallardo, Rafael; Segundo-Ramirez, Juan; Muljadi, Eduard

    2017-01-26

    This paper presents a comparative study of the application of Flexible AC Transmission System (FACTS) devices, as Thyristor Controlled Series Capacitor (TCSC), Static Synchronous Compensator (STATCOM) and Unified Power Controller (UPFC) on congestion management and voltage support in the area of the Istmo of Tehuantepec, Oaxaca, Mexico. The present work provides an analysis about the performance of the control of active and reactive power of the FACTS controllers applied to mentioned problems in the power system.

  6. Effects of electrical lesions of the medial preoptic area and the ventral pallidum on mate-dependent paternal behavior in mice.

    Science.gov (United States)

    Akther, Shirin; Fakhrul, Azam A K M; Higashida, Haruhiro

    2014-06-06

    In laboratory animals, less is known about the neural circuits that mediate paternal behavior than those that influence maternal behavior. In mice, we recently reported that when sires are separated with their mate dams from their pups, ultrasound and pheromonal signals from the dams can evoke and initiate maternal-like retrieval behavior in the sires upon reunion with the offspring; this is termed mate-dependent paternal care. We used electrolytic brain lesion (EBL) methods to identify the potential roles of the medial preoptic area (mPOA) and ventral pallidum (VP) regions in regulating paternal care, areas known to be critical for the expression of maternal behavior. Electrolytic lesions of the mPOA or VP disrupted mate-dependent paternal care; latencies to initiate pup retrieval, grooming and crouching were longer in the EBL-treated sires relative to the sham-operated mice. The number of grooming episodes and duration of crouching were also lower in sires with the EBL in both areas. These results indicate that the mPOA and VP regions are essential for mate-dependent paternal care in mice.

  7. Polygeneration smart grids. A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote areas

    Energy Technology Data Exchange (ETDEWEB)

    Kyriakarakos, George; Mohamed, Essam S.; Papadakis, George [Agricultural Univ. of Athens (Greece). Dept. of Natural Resources and Agricultural Engineering

    2010-07-01

    This paper presents the concept of polygeneration smart grids along with experimental results taken during winter 2009-2010 of a pilot polygeneration smart grid focusing on the evolution of the control strategy. In this smart grid the energy of the sun and the wind is harvested by photovoltaic panels and a wind turbine. The system products are electrical energy, potable water through desalination and hydrogen as both medium term energy storage and transportation fuel. Potable water is also used as seasonal energy storage. The components of the system include PV, a wind turbine, batteries, a PEM fuel cell, a PEM electrolyzer, metal hydride tank, hydrogen vehicle refueling subsystem, reverse osmosis desalination unit, data logging system and a control system. Two different controllers have been developed and tested for this smart grid; an ON/OFF controller which operates the electrolyzer, fuel cell and desalination unit at preset points and a fuzzy logic controller which allows for part load operation. The system is installed at the Agricultural University of Athens and the experimental process is ongoing. (orig.)

  8. Energy management of electric and hybrid vehicles dependent on powertrain configuration

    Science.gov (United States)

    Varga, Bogdan

    2012-06-01

    Electric and hybrid vehicles are going to become the most reliable source of transport for future years. The CO2 and NOx targets in Euro 6 normative puts the producers of vehicles in a dilemma, whether to adapt the internal combustion engines further, or to develop hybrid or electric power trains that are going to reach the pollution limit of the future norms or to go below that. Before acting a well-developed strategy in determining the optimum power flow has to be developed by producers; CRUISE software is a tool with the unique and special characteristics to determine the optimum in this highly important area. Whether electric vehicle, electric vehicle with range extender or a hybrid with CVT or planetary gearbox, the complexity of the mathematical modules remains the same, giving the developer the possibility to create complex functions and distinctive characteristics for each component of the vehicle. With such a powerful tool it becomes extremely easy to evaluate the energy flow in all directions, from electric machine to the battery, from electric machine to the power generator, and from the electric machine to the internal combustion engine. Applying to the (Electric Vehicle, Electric Vehicle with Range Extender, Hybrid vehicle with CVT, Hybrid vehicle with planetary gear set) the ECE-15 in a virtual environment (urban driving cycle) the simulation results show a different usage, rate of storage and efficiency concerning the energy, this being dependent of the power train configuration in most part.

  9. Reliability and validity in research.

    Science.gov (United States)

    Roberts, Paula; Priest, Helena

    This article examines reliability and validity as ways to demonstrate the rigour and trustworthiness of quantitative and qualitative research. The authors discuss the basic principles of reliability and validity for readers who are new to research.

  10. Misconceptions of Electric Propulsion Aircraft and Their Emergent Aviation Markets

    Science.gov (United States)

    Moore, Mark D.; Fredericks, Bill

    2014-01-01

    Over the past several years there have been aircraft conceptual design and system studies that have reached conflicting conclusions relating to the feasibility of full and hybrid electric aircraft. Some studies and propulsion discipline experts have claimed that battery technologies will need to improve by 10 to 20 times before electric aircraft can effectively compete with reciprocating or turbine engines. However, such studies have approached comparative assessments without understanding the compelling differences that electric propulsion offers, how these technologies will fundamentally alter the way propulsion integration is approached, or how these new technologies can not only compete but far exceed existing propulsion solutions in many ways at battery specific energy densities of only 400 watt hours per kilogram. Electric propulsion characteristics offer the opportunity to achieve 4 to 8 time improvements in energy costs with dramatically lower total operating costs, while dramatically improving efficiency, community noise, propulsion system reliability and safety through redundancy, as well as life cycle Green House Gas emissions. Integration of electric propulsion will involve far greater degrees of distribution than existing propulsion solutions due to their compact and scale-free nature to achieve multi-disciplinary coupling and synergistic integration with the aerodynamics, highlift system, acoustics, vehicle control, balance, and aeroelasticity. Appropriate metrics of comparison and differences in analysis/design tools are discussed while comparing electric propulsion to other disruptive technologies. For several initial applications, battery energy density is already sufficient for competitive products, and for many additional markets energy densities will likely be adequate within the next 7 years for vibrant introduction. Market evolution and early adopter markets are discussed, along with the investment areas that will fill technology gaps and

  11. EVALUATION OF THE GEOLOGICAL RELIABILITY OF SURFACE MINING DEPOSIT

    Institute of Scientific and Technical Information of China (English)

    韩金炎; 孙小彦; 彭世济

    1994-01-01

    The optimal decision theory and exploitation reliability of large scale mining area have heen studied in China since the late 1980′s. Researches have been carried out under the thought of mannature-machine system, and encouraging results have been obtained. The reliability evaluation of mining engineering includes the reliability evaluation of natural resources, mining technology and mine economics etc. And the geological reliability of deposit, as a natural condition, is the basis of all other evaluation works. The paper summarizes the method for evaluating the geological reliability of deposit, discusses the reliability of estimating methods for coal reserves and coal quality, evaluates the natural resources reliability of the Pit 1 of Antaibao, Surface Coal Mine, Pingsuo, Shanxi Province. which was taken as a case study.

  12. Electric Power

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ China Council for the Promotion of International Trade Electric Power Industry Office (CCPIT Electric Power), one of the pro-fessional industrial branches of China Council for the Promotion of International Trade (CCPIT), was established in 2006.

  13. Electricity economics

    CERN Document Server

    Hu, Zhaoguang

    2013-01-01

    Systematically analyzing for the first time the production output from electricity consumption for enterprises, sectors, and industries, this study uses the function of EAI (electricity as input), and includes national E-GDP figures for more than 20 countries.

  14. Reliability and Its Quantitative Measures

    Directory of Open Access Journals (Sweden)

    Alexandru ISAIC-MANIU

    2010-01-01

    Full Text Available In this article is made an opening for the software reliability issues, through wide-ranging statistical indicators, which are designed based on information collected from operating or testing (samples. It is developed the reliability issues also for the case of the main reliability laws (exponential, normal, Weibull, which validated for a particular system, allows the calculation of some reliability indicators with a higher degree of accuracy and trustworthiness

  15. On the reliability of frequency components in systolic arterial pressure in patients with atrial fibrillation.

    Science.gov (United States)

    Corino, Valentina D A; Lombardi, Federico; Mainardi, Luca T

    2010-04-01

    Atrial fibrillation (AF) is characterized by desynchronization of atrial electrical activity causing a consequent irregular ventricular response. In AF, the beat-to-beat variation of blood pressure is increased because of variations in filling time and contractility. However, only a few studies have analyzed short-term blood pressure variations in AF, and we have recently observed a harmonic low-frequency (LF) component in systolic arterial pressure (SAP) during AF. Aim of the present study is to propose a method to verify the reliability of the spectral component found in SAP series, based on the position of the poles of the autoregressive spectral decomposition in the z-plane. In particular, 1,000 random permutations of the series allowed the definition of an area in the z-plane where poles from random process are likely to occur. Poles lying outside this area are considered as reliable oscillations. We tested the method on 53 recordings obtained at rest from patients with persistent AF. LF component was found in, respectively, 51 and 43 recordings in SAP and RR series. High-frequency (HF) component was found in all the recordings for both SAP and RR series. Using the proposed test, the percentage of reliable components in LF and HF bands was 80 and 38 in SAP series, and 20 and 18 in RR series. We concluded that, at variance with RR ones, SAP LF components are likely to represent true physiological oscillations.

  16. Reliability assessment of wave Energy devices

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kramer, Morten; Kofoed, Jens Peter

    2014-01-01

    methods. Extreme loads during normal operation, but also extreme loads simultaneous with failure of mechanical and electrical components as well as the control system, are of importance for WEDs. Furthermore, fatigue loading needs to be assessed. This paper focus on the Wavestar prototype which is located...... near Hanstholm (DK). In the present paper, a generic example for an extreme limit state is considered. The extreme limit state case considers important failure modes of the system which are determined by a Fault Tree Analysis (FTA) and Failure Mode and Effects Analysis (FMEA). The resulting reliability...

  17. Reliability and quality EEE parts issues

    Science.gov (United States)

    Barney, Dan; Feigenbaum, Irwin

    1990-01-01

    NASA policy and procedures are established which govern the selection, testing, and application of electrical, electronic, and electromechanical (EEE) parts. Recent advances in the state-of-the-art of electronic parts and associated technologies can significantly impact the electronic designs and reliability of NASA space transportation avionics. Significant issues that result from these advances are examined, including: recent advances in microelectronics technology (as applied to or considered for use in NASA projects); electron packaging technology advances (concurrent with, and as a result of, the development of the advanced microelectronic devices); availability of parts used in space avionics; and standardization and integration of parts activities between projects, centers, and contractors.

  18. Reliability and Power Quality Evaluation of High-Voltage Supplied Customer

    Science.gov (United States)

    Yoshino, Jun; Kita, Hiroyuki; Tanaka, Eiichi; Hasegawa, Jun; Kubo, Hiroshi; Yonaga, Shigeru

    Recently, a number of electric consumers have concerned about the reliability of electricity to be served. For example, some consumers need the electricity with a higher reliability by the automation of manufacturing processes. On the other hand, some consumers need the electricity of a cheaper price even if the reliability becomes a little worse. Under such circumstances, it is necessary that power suppliers evaluate the needs of every consumers precisely and propose the most desirable measures for meeting their requirements. This paper develops a tool to analyze the reliability for high-voltage supplied consumers quantitatively. Further, this paper presents a method for evaluating the outage cost of consumers to help them choose the most appropriate measures for maintaining the reliability. The proposed method applies the fuzzy reasoning approach. The validity of the proposed method is ascertained through some numerical simulations.

  19. Reliability of measuring regional callosal atrophy in neurodegenerative diseases

    Directory of Open Access Journals (Sweden)

    Jeroen Van Schependom, MSc Eng, PhD

    2016-01-01

    In summary, we have constructed an algorithm that reliably detects the CC in 3D T1 images in a fully automated way in healthy controls and different neurodegenerative diseases. Although the CC area and the circularity are the most reliable features (ICC > 0.97; the reliability of the thickness profile (ICC > 0.90; excluding the tip is sufficient to warrant its inclusion in future clinical studies.

  20. Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from both of point and area sources of an electric-arc furnace-dust treatment plant and their impacts to the vicinity environments.

    Science.gov (United States)

    Yu, Kuei-Min; Lee, Wen-Jhy; Tsai, Perng-Jy; Fang, Kenneth; Lin, Mark

    2010-08-01

    This study was set out to investigate emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from both the stack (i.e., point source) and plant fugitives (i.e., area source) of an electric-arc furnace-dust treatment plant (EAFDTP) and their impact to the vicinity environments. The emission rate of the point source (2,360 ng I-TEQh(-1)) was determined directly by measuring PCDD/F concentrations of the stack flue gas. The emission rate of the area source (1,080 ng I-TEQ m(-2)h(-1)) was estimated by using the Industrial Sources Complex Short-Term (ISCST3) model based on concentrations measured at the downwind side of the plant. The mean emission factors of 785 and 893 ng I-TEQ ton(-1) ZnO were found for the point and area source, respectively. The above results suggest that the area source accounted for more than 50% of total PCDD/F emissions for the selected EAFDTP. The contribution of the point source to the atmospheric PCDD/F concentrations of the upwind site and downwind site of the EAFDTP were 0 and 0.27 fg I-TEQ Nm(-3), respectively. The contributions of the area source were 0.020 and 3.3 fg I-TEQ Nm(-3), respectively. The total contribution of the selected EAFDTP (including both the point and area sources) to the concentrations in both upwind and downwind side vicinities were all less than 10%. Finally, the impact of PCDD/F emissions from the selected EAFDTP to the vicinity atmospheric environments was discussed in the present study.