  1. National Ignition Facility subsystem design requirements laser and target area building (LTAB) SSDR 1.2.2.1

    International Nuclear Information System (INIS)

    Kempel, P.; Hands, J.

    1996-01-01

    This Subsystem Design Requirements (SSDR) document establishes the performance, design, and verification requirements for the conventional building systems and subsystems of the Laser and Target Area Building (LTAB), including those that house and support the operation of high-energy laser equipment and the operational flow of personnel and materials throughout the facility. This SSDR addresses the following subsystems associated with the LTAB: Building structural systems for the Target Bay, Switchyards, Diagnostic Building, Decontamination Area, Laser Bays, Capacitor Bays and Operations Support Area, and the necessary space associated with building-support equipment; Architectural building features associated with housing the space and with the operational cleanliness of the functional operation of the facilities; Heating, Ventilating, and Air Conditioning (HVAC) systems for maintaining a clean and thermally stable ambient environment within the facilities; Plumbing systems that provide potable water and sanitary facilities for the occupants, plus stormwater drainage for transporting rainwater; Fire Protection systems that guard against fire damage to the facilities and their contents; Material handling systems for transporting personnel and heavy materials within the building areas; Mechanical process piping systems for liquids and gases that provide cooling and other service to experimental laser equipment and components; Electrical power and grounding systems that provide service and standby power to building and experimental equipment, including lighting distribution and communications systems for the facilities; Instrumentation and control systems that ensure the safe operation of conventional facilities systems, such as those listed above. Detailed requirements for building subsystems that are not addressed in this document (such as specific sizes, locations, or capacities) are included in detail-level NIP Project Interface Control Documents (ICDS)

  2. National Ignition Facility subsystem design requirements optics assembly building (OAB) SSDR 1.2.2.3

    International Nuclear Information System (INIS)

    Kempel, P.; Hands, J.

    1996-01-01

    This Subsystem Design Requirement (SSDR) document establishes the performance, design, and verification requirements 'for the conventional building systems and subsystems of the Optics Assembly Building (OAB). These building system requirements are associated with housing and supporting the operational flow of personnel and materials throughout the OAB for preparing and repairing optical and mechanical components used in the National Ignition Facility (NIF) Laser and Target Building (LTAB). This SSDR addresses the following subsystems associated with the OAB: * Structural systems for the building spaces and operational-support equipment and building- support equipment. * Architectural building features associated with housing the space, operational cleanliness, and functional operation of the facility. * Heating, Ventilating, and Air Conditioning (HVAC) systems for maintaining a clean and thermally stable ambient environment within the facility. * Plumbing systems that provide potable water and sanitary facilities for the occupants and stormwater drainage for transporting rainwater. * Fire Protection systems that guard against fire damage to the facility and its contents. * Material handling equipment for transferring optical assemblies and other materials within building areas and to the LTAB. * Mechanical process piping systems for liquids and gases that provide cooling, cleaning, and other service to optical and mechanical components. * Electrical power and grounding systems that provide service to the building and equipment, including lighting distribution and communications systems for the facilities. * Instrumentation and control systems that ensure the safe operation of conventional facilities systems, such as those listed above. Generic design criteria, such as siting data, seismic requirements, utility availability, and other information that contributes to the OAB design, are not addressed in this document

  3. Impact of the buildings areas on the fire incidence.

    Science.gov (United States)

    Srekl, Jože; Golob, Janvit

    2010-03-01

    A survey of statistical studies shows that probability of fires is expressed by the equation P(A) = KAα, where A = total floor area of the building and K and  are constants for an individual group, or risk category. This equation, which is based on the statistical data on fires in Great Britain, does not include the impact factors such as the number of employees and the activities carried out in these buildings. In order to find out possible correlations between the activities carried out in buildings, the characteristics of buildings and number of fires, we used a random sample which included 134 buildings as industrial objects, hotels, restaurants, warehouses and shopping malls. Our study shows that the floor area of buildings has low impact on the incidence of fires. After analysing the sample of buildings by using multivariate analysis we proved a correlation between the number of fires, floor area of objects, work operation period (per day) and the number of employees in objects.

  4. Segmentation of Shadowed Buildings in Dense Urban Areas from Aerial Photographs

    OpenAIRE

    Susaki, Junichi

    2012-01-01

    Segmentation of buildings in urban areas, especially dense urban areas, by using remotely sensed images is highly desirable. However, segmentation results obtained by using existing algorithms are unsatisfactory because of the unclear boundaries between buildings and the shadows cast by neighboring buildings. In this paper, an algorithm is proposed that successfully segments buildings from aerial photographs, including shadowed buildings in dense urban areas. To handle roofs having rough text...

  5. MINIMUM AREAS FOR ELEMENTARY SCHOOL BUILDING FACILITIES.

    Science.gov (United States)

    Pennsylvania State Dept. of Public Instruction, Harrisburg.

    MINIMUM AREA SPACE REQUIREMENTS IN SQUARE FOOTAGE FOR ELEMENTARY SCHOOL BUILDING FACILITIES ARE PRESENTED, INCLUDING FACILITIES FOR INSTRUCTIONAL USE, GENERAL USE, AND SERVICE USE. LIBRARY, CAFETERIA, KITCHEN, STORAGE, AND MULTIPURPOSE ROOMS SHOULD BE SIZED FOR THE PROJECTED ENROLLMENT OF THE BUILDING IN ACCORDANCE WITH THE PROJECTION UNDER THE…

  6. Small Buildings in Earthquake Areas. Educational Building Digest 2.

    Science.gov (United States)

    Mooij, D.

    This booklet is intended for builders and others who actually construct small buildings in earthquake areas and not for professionally qualified architects or engineers. In outline form with sketches the following topics are discussed: general construction and design principles; foundations; earth walls; brick, block, and stone walls; timber frame…

  7. Building Capacity for Protected Area Management in Lao PDR

    Science.gov (United States)

    Rao, Madhu; Johnson, Arlyne; Spence, Kelly; Sypasong, Ahnsany; Bynum, Nora; Sterling, Eleanor; Phimminith, Thavy; Praxaysombath, Bounthob

    2014-04-01

    Declining biodiversity in protected areas in Laos is attributed to unsustainable exploitation of natural resources. At a basic level, an important need is to develop capacity in academic and professional training institutions to provide relevant training to conservation professionals. The paper (a) describes the capacity building approach undertaken to achieve this goal, (b) evaluates the effectiveness of the approach in building capacity for implementing conservation and (c) reviews implementation outcomes. Strong linkages between organizations implementing field conservation, professional training institutions, and relevant Government agencies are central to enhancing effectiveness of capacity building initiatives aimed at improving the practice of conservation. Protected area management technical capacity needs will need to directly influence curriculum design to insure both relevance and effectiveness of training in improving protected area management. Sustainability of capacity building initiatives is largely dependent on the level of interest and commitment by host-country institutions within a supportive Government policy framework in addition to engagement of organizations implementing conservation.

  8. Segmentation of Shadowed Buildings in Dense Urban Areas from Aerial Photographs

    Directory of Open Access Journals (Sweden)

    Junichi Susaki

    2012-03-01

    Full Text Available Segmentation of buildings in urban areas, especially dense urban areas, by using remotely sensed images is highly desirable. However, segmentation results obtained by using existing algorithms are unsatisfactory because of the unclear boundaries between buildings and the shadows cast by neighboring buildings. In this paper, an algorithm is proposed that successfully segments buildings from aerial photographs, including shadowed buildings in dense urban areas. To handle roofs having rough textures, digital numbers (DNs are quantized into several quantum values. Quantization using several interval widths is applied during segmentation, and for each quantization, areas with homogeneous values are labeled in an image. Edges determined from the homogeneous areas obtained at each quantization are then merged, and frequently observed edges are extracted. By using a “rectangular index”, regions whose shapes are close to being rectangular are thus selected as buildings. Experimental results show that the proposed algorithm generates more practical segmentation results than an existing algorithm does. Therefore, the main factors in successful segmentation of shadowed roofs are (1 combination of different quantization results, (2 selection of buildings according to the rectangular index, and (3 edge completion by the inclusion of non-edge pixels that have a high probability of being edges. By utilizing these factors, the proposed algorithm optimizes the spatial filtering scale with respect to the size of building roofs in a locality. The proposed algorithm is considered to be useful for conducting building segmentation for various purposes.

  9. Comfort Study of Office Buildings with Large Glazed Areas

    Directory of Open Access Journals (Sweden)

    Violeta Motuzienė

    2017-09-01

    Full Text Available In the buildings with large glazed areas the biggest problem is the space overheating during the warm season. This causes increased energy demand for cooling. The survey was carried out during the warm and cold seasons in two office buildings with large glazed areas. The methodology was prepared for evaluating indoor climate parameters using objective and subjective evaluation. The measurements have shown that there are problems with lighting in workplaces of both buildings during both the warm and cold seasons. The biggest problem is too dry air during the cold period, an acceptable temperature is also not always in the building No. 2. The survey has shown that some employees are dissatisfied with the indoor climate in the workplace, the bigger dissatisfaction is in building No. 2. Assessing according to the O. Fanger methodology was obtained that the number of PPD is in the normal range during the cold period, whereas close to the limit when the building can not be operated in the warm period.

  10. 14 CFR 151.93 - Buildings; utilities; sidewalks; parking areas; and landscaping.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Buildings; utilities; sidewalks; parking....93 Buildings; utilities; sidewalks; parking areas; and landscaping. (a) Only buildings or parts of buildings intended to house facilities or activities directly related to the safety of persons at the...

  11. Application issues for large-area electrochromic windows incommercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; DiBartolomeo, D.L.

    2000-05-01

    Projections of performance from small-area devices to large-area windows and enterprise marketing have created high expectations for electrochromic glazings. As a result, this paper seeks to precipitate an objective dialog between material scientists and building-application scientists to determine whether actual large-area electrochromic devices will result in significant performance benefits and what material improvements are needed, if any, to make electrochromics more practical for commercial building applications. Few in-situ tests have been conducted with large-area electrochromic windows applied in buildings. This study presents monitored results from a full-scale field test of large-area electrochromic windows to illustrate how this technology will perform in commercial buildings. The visible transmittance (Tv) of the installed electrochromic ranged from 0.11 to 0.38. The data are limited to the winter period for a south-east-facing window. The effect of actual device performance on lighting energy use, direct sun control, discomfort glare, and interior illumination is discussed. No mechanical system loads were monitored. These data demonstrate the use of electrochromics in a moderate climate and focus on the most restrictive visual task: computer use in offices. Through this small demonstration, we were able to determine that electrochromic windows can indeed provide unmitigated transparent views and a level of dynamic illumination control never before seen in architectural glazing materials. Daily lighting energy use was 6-24 percent less compared to the 11 percent-glazing, with improved interior brightness levels. Daily lighting energy use was 3 percent less to 13 percent more compared to the 38 percent-glazing, with improved window brightness control. The electrochromic window may not be able to fulfill both energy-efficiency and visual comfort objectives when low winter direct sun is present, particularly for computer tasks using cathode-ray tube (CRT

  12. Integration of PV modules in existing Romanian buildings from rural areas

    Energy Technology Data Exchange (ETDEWEB)

    Fara, S.; Finta, D. [IPA SA Research Development, Engineering and Manufacturing for Automation Equipment and Systems, Bucharest (Romania); Fara, L.; Comaneci, D. [Polytechnic Univ. of Bucharest (Romania); Dabija, A.M. [Univ. of Architecture and Urbanism Ion Mincu, Bucharest (Romania); Tulcan-Paulescu, E. [West Univ. of Timisoara, Timisoara (Romania)

    2010-07-01

    Romania has launched a national research project to promote the use of distributed solar architecture and the use of BIPV systems. These systems include solar tunnels and active solar photovoltaic (PV) systems installed on the roofs and facades of buildings in rural areas. In contrast to other EU states, Romania does not have a photovoltaic building construction branch. The number of isolated cases are insufficient to identify a starting point regarding the PV market in the building industry. The main objective of the project is to demonstrate the efficiency of integrating various PV elements in buildings from rural areas, to test them and to make them known so that they can be used on a large scale. This will be accomplished by installing new products on 2 buildings in Bucharest and in 1 building in Timisoara. The PV modules will be integrated with the architecture. One of the buildings will be a historical building while the other 2 will be new buildings with different typologies. The installed power for each building will be of about 1.000 Wp, including some technologies with PV modules.

  13. Tornado Protection: Selecting and Designing Safe Areas in Buildings.

    Science.gov (United States)

    Abernethy, James J.

    Tornadoes and extreme winds cause heavy loss of life and property damage throughout the United States. Most buildings offer significant protection from this danger, and building administrators should know the areas where this protection is available. This booklet presents a review of three schools, all of which were struck by tornadoes on April 3,…

  14. Serviceability criteria for buildings in mine subsidence area -- Adjustment to Eurocodes

    International Nuclear Information System (INIS)

    Kawulok, M.; Sulimowski, Z.

    1994-01-01

    Due to ground deformations caused by underground mining, building structures in mining areas are frequently subjected to considerable deformations and damage to the finishing and structural elements. As a consequence, serviceable values of such structures are distinctly diminished, and in extreme cases, seriously damaged structures may be exempted from further service. These problems are not duly represented in the existing building standard codes. It is also important to determine relationship between damage stage and value of the building, and hence the strategy for reconstruction or renovation works. The paper presents proposals concerning serviceability criteria of building structures in mining areas, in terms of basic standard requirements valid in building in Poland, as well as proposals of Eurocodes. Building structures under consideration have been divided into structures designed to resist mining influences and existing structures, not adapted to conform to these influences at the design and erection stages

  15. The potential to supply low temperature district heating to existing building area

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2013-01-01

    Low-temperature district heating (LTDH) has the advantages as reduced network heat loss, improved quality match between energy supply and energy demand, and increased utilization of low-grade waste heat and renewable energy. The LTDH represents the next generation district heating (DH) system...... to supply existing building areas which are characterized with high heating demand needs to be examined. In this paper, the DH network deliverable capacity to supply LTDH to an existing building area is studied based on building thermal performance and DH network hydraulic performance simulation....

  16. Artificial intelligence applications in fixed area monitor for TRIGA reactor building and service building

    International Nuclear Information System (INIS)

    Talpalariu, C.; Talpalariu, J.; Vaja, N.; Matei, C.

    2008-01-01

    This system is intended for the protection of personnel working in those areas of the Reactor Building and Service Building where high gamma radiation fields are expected. A detector, sensitive to gamma radiation, is installed in each of the areas to be monitored. The detector will send a signal, proportional to the radiation level in the area, to a corresponding electronic module (Alarm Unit), where the signal will be amplified and checked against alarm set points for possible alarming conditions. In case the field exceeds the alarm set values, the Alarm Unit will produce a signal that will trigger the field alarms (Horn and Beacon) located in the area where the condition occurred. Each Alarm Unit will send a numerical input to central computer command. he system is required to accomplish the following tasks: - Monitors the level of gamma radiation in those areas of the Station where high radiation fields are expected; - Provides a continuous and centralized display of the radiation level in each of the monitored areas. The display shall be in exposure rate units (R/h); - Provides a visual and audible alarm in each monitored areas; Allows the control room operator to check at any time the radiation levels and alarm conditions in each of the monitored areas; - Control room operator shall be alerted of any alarm conditions that occurs in the Station. A typical monitoring loop is composed of the following components: Detector Assembly type: CI-MA - 522 two channels, two ranges; Horn and Beacon Assembly; Remote Indicating Meter with Warning Lights; Central computer; common equipment for all 40 loops. (authors)

  17. Information support of monitoring of technical condition of buildings in construction risk area

    Science.gov (United States)

    Skachkova, M. E.; Lepihina, O. Y.; Ignatova, V. V.

    2018-05-01

    The paper presents the results of the research devoted to the development of a model of information support of monitoring buildings technical condition; these buildings are located in the construction risk area. As a result of the visual and instrumental survey, as well as the analysis of existing approaches and techniques, attributive and cartographic databases have been created. These databases allow monitoring defects and damages of buildings located in a 30-meter risk area from the object under construction. The classification of structures and defects of these buildings under survey is presented. The functional capabilities of the developed model and the field of it practical applications are determined.

  18. Analysis of heat source selection for residential buildings in rural areas

    OpenAIRE

    Szul Tomasz

    2018-01-01

    The research aiming to check whether the output of currently installed boilers matches the use requirements together with estimation of their energy efficiency was carried out on a group of 84 single-family residential buildings located in rural areas. Heating and hot water energy needs were calculated for each building in order to determine the use requirements. This enabled verification whether the currently installed boilers match the actual use requirements in the buildings. Based on the ...

  19. Appendix D-12A Building 332C Waste Accumulation Area

    International Nuclear Information System (INIS)

    Chase, D

    2005-01-01

    This appendix is designed to provide information specific to the Building 332C Waste Accumulation Area (B-332C WAA), a waste storage area. This appendix is not designed to be used as a sole source of information. All general information that is not specific to the B-332C WAA is included in the Contingency Plan for Waste Accumulation Areas, dated July 2004, and should be referenced. The B-332C WAA is located in the southwest quadrant of the LLNL Main Site in Building 332, Room 1330. Hazardous and mixed wastes may be stored at the B-332C WAA for 90 days or less, until transferred to the appropriate Radioactive and Hazardous Waste Management (RHWM) facility or other permitted treatment, storage or disposal facility (TSDF). Radioactive waste may also be stored at the WAA. The design storage capacity of this WAA is 2,200 gallons

  20. Radon concentrations inside public and commercial buildings in the Pittsburgh area

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, B L; Kulwicki, D R; Warner, Jr, K R; Grassi, C L

    1984-09-01

    Radon concentrations in ambient air from numerous schools, stores and other public and commercial buildings in the Pittsburgh, PA, area were measured by grab sampling. This is more appropriate than using long-term integrating monitors because of the correlation between times of occupancy and Rn levels. Results indicate that Rn concentrations in these buildings are nearly an order of magnitude less than in homes, and not much higher than outdoors. Variations among sites is also much less than for homes, probably because there is less variability in ventilation and building maintenance practices. Colleges and universities have somewhat higher Rn levels and a larger degree of variability than commercial buildings or hospitals. There was no indication of higher Rn levels in cold weather than in warm weather, or of correlations with the age of the building.

  1. Radon concentrations inside public and commercial buildings in the Pittsburgh area.

    Science.gov (United States)

    Cohen, B L; Kulwicki, D R; Warner, K R; Grassi, C L

    1984-09-01

    Radon concentrations in ambient air from numerous schools, stores and other public and commercial buildings in the Pittsburgh, PA, area were measured by grab sampling. This is more appropriate than using long-term integrating monitors because of the correlation between times of occupancy and Rn levels. Results indicate that Rn concentrations in these buildings are nearly an order of magnitude less than in homes, and not much higher than outdoors. Variations among sites is also much less than for homes, probably because there is less variability in ventilation and building maintenance practices. Colleges and universities have somewhat higher Rn levels and a larger degree of variability than commercial buildings or hospitals. There was no indication of higher Rn levels in cold weather than in warm weather, or of correlations with the age of the building.

  2. Importance of determination of the radon risk of the area for building before the building of every stay building

    International Nuclear Information System (INIS)

    Pinter, I.; Vicanova, M.

    1997-01-01

    In this paper the authors are dilating with the analyse of the equivalent volume activity of the radon in the flat's spaces and of the geological environment in the Slovak Republic. Nevertheless, that for the time being it is not explicitly legislative determined obligation of the discovering of the radon risk of the area of the planned housing, the the ends from up to now realized researches corroborate us the relevance of the quoted problem on the area of the Slovak Republic and the necessity of the determination of the radon risk of the area of the housing of the every inhabitable building [sk

  3. 100 Area D4 Project Building Completion Report: December 2008 to December 2009

    International Nuclear Information System (INIS)

    Finucane, K.G.; Harrie, J.P.

    2010-01-01

    This report documents the final status of buildings after the completion of D4 activities at the 100 Area of the U.S. Department of Energy Hanford Site from December 1, 2008, to December 31, 2009. The following buildings are included in this report: 11-N Change Room; 13-N Storage Building; 107-N Basin Recirculation Facility; 108-N Chemical Unloading Facility; 183-ND Resin Disposal Pit; 183-F Clearwells; 188-D Ash Disposal Pit; 1524-N Hazardous Waste Storage Pad; 1525-N Laydown Storage Area; 1607-Ni Sewage Tank; 1607-N2 Sewage Tank; 1706-NA Sewage Lift Station; 1904-D Outfall Structure; MO-013 Mobile Office Trailer; MO-422 Mobile Office Trailer; and MO-999 Mobile Office Trailer. Demolition debris and soil associated with completion of these buildings were disposed at the Environmental Restoration Disposal Facility (ERDF), located at the Hanford Site. Postdemolition direct hand instrument surveys and Global Positioning Environmental Radiological Survey (GPERS) surveys were performed on excavations after loadout of debris and prior to backfill. The 100 Area D4/Interim Safe Storage (ISS) project personnel worked a total of approximately 137,930 hours (manual and non-manual, not including subcontractors) from December 1, 2008, to December 31, 2009. During this time there were 10 Occupational Safety and Health Administration (OSHA) recordable injuries, two of which involved lost time. There also were 27 first aid cases during this time period. No clothing contamination and no skin contamination incidents occurred during demolition of the 100 Area buildings. Workers received 7,350.2 person-mrem of radiological exposure from December 1, 2008, to December 31, 2009 during their support of D4 activities associated with the buildings discussed in this report. All boundary air sample results were below procedural action levels for the duration of the work performed.

  4. Polychlorinated biphenyls in the exterior caulk of San Francisco Bay Area buildings, California, USA.

    Science.gov (United States)

    Klosterhaus, Susan; McKee, Lester J; Yee, Donald; Kass, Jamie M; Wong, Adam

    2014-05-01

    Extensive evidence of the adverse impacts of polychlorinated biphenyls (PCBs) to wildlife, domestic animals, and humans has now been documented for over 40 years. Despite the ban on production and new use of PCBs in the United States in 1979, a number of fish consumption advisories remain in effect, and there remains considerable uncertainty regarding ongoing environmental sources and management alternatives. Using a blind sampling approach, 25 caulk samples were collected from the exterior of ten buildings in the San Francisco Bay Area and analyzed for PCBs using congener-specific gas chromatography-mass spectrometry (GC-MS) and chlorine using portable X-ray fluorescence (XRF). PCBs were detected in 88% of the caulk samples collected from the study area buildings, with 40% exceeding 50 ppm. Detectable PCB concentrations ranged from 1 to 220,000 ppm. These data are consistent with previous studies in other cities that have identified relatively high concentrations of PCBs in concrete and masonry buildings built between 1950 and 1980. Portable XRF was not a good predictor of the PCB content in caulk and the results indicate that portable XRF analysis may only be useful for identifying caulk that contains low concentrations of Cl (≤ 10,000 ppm) and by extension low or no PCBs. A geographic information system-based approach was used to estimate that 10,500 kg of PCBs remain in interior and exterior caulk in buildings located in the study area, which equates to an average of 4.7 kg PCBs per building. The presence of high concentrations in the exterior caulk of currently standing buildings suggests that building caulk may be an ongoing source of PCBs to the San Francisco Bay Area environment. Further studies to expand the currently small international dataset on PCBs in caulking materials in buildings of countries that produced or imported PCBs appear justified in the context of both human health and possible ongoing environmental release. Copyright © 2014 Elsevier

  5. Building adaptive capacity for flood proofing in urban areas through synergistic interventions

    NARCIS (Netherlands)

    Veerbeek, W.; Ashley, R.M.; Zevenbergen, C.; Rijke, J.S.; Gersonius, B.

    2010-01-01

    Few, if any urban areas are nowadays built in isolation from existing developments. Therefore, urban expansion and making existing urban areas more sustainable is a contemporary goal. There are major opportunities to do this through the ‘normal’ renewal of urban infrastructure and building stocks

  6. Potential building sand deposits in Songkhla province area

    Directory of Open Access Journals (Sweden)

    Kooptarnond, K.

    2002-10-01

    Full Text Available An investigation of potential building sand deposits in Songkhla province area subdivided them into four regions according to their accumulation in various alluvial plains, meanders throughout alluvial deposits and residual soils. Four selected deposits, were Rattaphum-Khuan Niang, U-Taphao river, Na Mom, and Chana-Thepha regions. Information obtained from these deposits revealed a good correlation between the geomorphological features as interpreted from aerial photographs and those identified from vertical electrical resistivity sounding results. Sand samples were analysed for their physical and chemical properties. Petrographic studies were also undertaken to characterize the composition types, texture and shapes. An overview of the sand properties was used them to be within the acceptable limits for building sand. However, relatively high organic impurities and soundness were found in sand from Khuan Niang and Na Mom deposits. The result indicated a potential reconnaissance mineral resource of about 46 square kilometres.A reserve evaluation for natural building sand was carried out by using Geographic Information System (GIS. Maps of the various parameters considered were constructed in digital database format with the aid of Arc/Info and ArcView software. Overlay mapping and buffer zone modules were performed to evaluate inferred resources of building sand. The key parameters of analysis included the distance from transportation, distance from streams, lithology and thickness of sand layers. The remaining inferred sand total was of about 386 million cubic metres or about 1,021 million metric tons was therefore estimated, of which 60 percent lies in the Rattaphum-Khuan Niang region and 40 percent in the other regions.

  7. Research on Building Urban Sustainability along the Coastal Area in China

    OpenAIRE

    Sun Jiaojiao; Fu Jiayan

    2015-01-01

    At present, in China, the research about the urban sustainability construction is still in the exploratory stage. The ecological problems of the coastal area are more sensitive and complicated. In the background of global warming with serious ecological damage, this paper deeply researches on the main characteristics of urban sustainability and measures how to build urban sustainability. Through combining regional environmental with economic ability along the coastal area...

  8. The simulated measurements of area and personal neutron-gamma dose equivalent in the building of HWRR

    International Nuclear Information System (INIS)

    Chen Changmao; Wen Youqin; Su Jingling; Liu Shuying; Liu Nairong

    1988-01-01

    The measuring methods and results for area and personal n-γ dose equivalent in the building of HWRR of Institute of Atomic Energy were reported. The reactor operated 4440 hours during 1985, the average themal power was 11 MW. The average area n-γ dose equivalents of the basement, experimental hall, corridors and laboratories in the building were 12.2, 11.6, 0.45 and 0.23 cSv/a, respectively. The fraction of the neutron dose equivalent in any working area was less than 21%. The average personal n-γ dose equivalent to radiation workers in the building was about 0.49 cSv/a, the γ dose equivalent was a major component. The measuring methods were compared

  9. Analysis of heat source selection for residential buildings in rural areas

    Directory of Open Access Journals (Sweden)

    Szul Tomasz

    2018-01-01

    Full Text Available The research aiming to check whether the output of currently installed boilers matches the use requirements together with estimation of their energy efficiency was carried out on a group of 84 single-family residential buildings located in rural areas. Heating and hot water energy needs were calculated for each building in order to determine the use requirements. This enabled verification whether the currently installed boilers match the actual use requirements in the buildings. Based on the calculations it was determined that the designed average boiler output in the group of buildings subject to analysis is 15.7 kW, whereas the mean rated output capacity of boilers installed therein is 25.4 kW. On average, the output capacity of the installed boilers exceeds the use requirements for the buildings by 60%. To calculate the energy efficiency of boilers, the mean annual boiler output capacity use coefficient was determined. For boilers selected on the basis of standard calculations, the mean coefficient is 0.47. For boilers currently in use it is 0.31, less than the above figure. The above calculations show that if boilers were correctly selected in compliance to the building needs, then the average estimated seasonal efficiency of 65% would be feasible. However, in the current state the achievable efficiency is approx. 55%.

  10. 324 Building radiochemical engineering cells, high-level vault, low-level vault, and associated areas closure plan

    International Nuclear Information System (INIS)

    Barnett, J.M.

    1998-01-01

    The Hanford Site, located adjacent to and north of Richland, Washington, is operated by the US Department of Energy, Richland Operations Office (RL). The 324 Building is located in the 300 Area of the Hanford Site. The 324 Building was constructed in the 1960s to support materials and chemical process research and development activities ranging from laboratory/bench-scale studies to full engineering-scale pilot plant demonstrations. In the mid-1990s, it was determined that dangerous waste and waste residues were being stored for greater than 90 days in the 324 Building Radiochemical Engineering Cells (REC) and in the High-Level Vault/Low-Level Vault (HLV/LLV) tanks. [These areas are not Resource Conservation and Recovery Act of 1976 (RCRA) permitted portions of the 324 Building.] Through the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-89, agreement was reached to close the nonpermitted RCRA unit in the 324 Building. This closure plan, managed under TPA Milestone M-20-55, addresses the identified building areas targeted by the Tri-Party Agreement and provides commitments to achieve the highest degree of compliance practicable, given the special technical difficulties of managing mixed waste that contains high-activity radioactive materials, and the physical limitations of working remotely in the areas within the subject closure unit. This closure plan is divided into nine chapters. Chapter 1.0 provides the introduction, historical perspective, 324 Building history and current mission, and the regulatory basis and strategy for managing the closure unit. Chapters 2.0, 3.0, 4.0, and 5.0 discuss the detailed facility description, process information, waste characteristics, and groundwater monitoring respectively. Chapter 6.0 deals with the closure strategy and performance standard, including the closure activities for the B-Cell, D-Cell, HLV, LLV; piping and miscellaneous associated building areas. Chapter 7.0 addresses the

  11. Hazard classification methodology

    International Nuclear Information System (INIS)

    Brereton, S.J.

    1996-01-01

    This document outlines the hazard classification methodology used to determine the hazard classification of the NIF LTAB, OAB, and the support facilities on the basis of radionuclides and chemicals. The hazard classification determines the safety analysis requirements for a facility

  12. Athena kinos linastuvad friigifilmid

    Index Scriptorium Estoniae

    2008-01-01

    Uuest filmisarjast "Ainult friikidele". Sari linastub alates 25. veebruarist igal teisel esmaspäeval kinos Sõprus ja teisipäeval Tartu Athena Keskuses. Programm vältab ligi kuus kuud, 29. juulini. Esimese hooaja teemaks on ühiskondlikud ebakõlad

  13. Energy and Environmental Research in the Building Area; Forschen und Bauen im Kontext von Energie und Umwelt

    Energy Technology Data Exchange (ETDEWEB)

    Binz, A. [Fachhochschule Nordwestschweiz (HABG-IEB), Muttenz (Switzerland); Chianese, D. [Scuola Universitaria Professionale della Svizzera Italiana, Dipartimento Ambiente Costruzioni e Design, Instituto di Sostenibilita Applicata all' Ambiente Costruito (SUPSI-DACD-ISAAC), Canobbio (Switzerland); Filleux, Ch. [Basler und Hofmann, Zuerich (Switzerland); Gaegauf, Ch. [Oekozentrum Langenbruck, Langenbruck (Switzerland); Gugerli, H. [Amt fuer Hochbauten der Stadt Zuerich, Zuerich (Switzerland); Menti, U.-P. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland); Rommel, M. [Hochschule fuer Technik, Institut fuer Solartechnik (SPF), Rapperswil (Switzerland); Schwehr, P. [brenet, building and renewable energies network of technology, HTA Luzern, Horw (Switzerland); Zimmermann, M. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland)

    2010-07-01

    These proceedings of the 16{sup th} Swiss Status Seminar held in September 2010 at the Swiss Federal Institute of Technology ETH in Zurich, Switzerland, present a comprehensive overview of the two-day event on Swiss energy and environmental topics in the building area. A total of 55 lectures in ten sessions covered architectural and building topics. The main lectures at the beginning of the seminar covered models for sustainable city development, building for the 2000-watt society and design principles. Also the 'Tropical House' project, the 'Self' autonomous house, the new Monte Rosa mountaineers hut and the Swiss Village project in Masdar were presented. The presentations were divided into nine thematic areas: The house as a 'power station', building renewal, energy management, heat pumps, processes, innovative building and renovation, city districts, building technologies, ventilation and the building as a system. Twenty poster contributions completed the seminar. Themes addressed in the 'house as a power station' set looked at the local generation of power, buildings that generate or even export energy and low-energy consumption buildings. Building renewal topics discussed included grey energy and legal topics, energy management contributions dealt with control, hot water preparation and energy efficiency. The heat pump section dealt with theory and practice of heating and cooling, multi-functional and low-exergy systems and related calculation aids. The processes section included contributions on infra-red analysis, solar-assisted systems, modelling, eco-balances and the City of Zurich's resource strategy for mineral building materials. Innovative building and renovation topics included renovation with prefabricated elements, integrated photovoltaic modules, retrofits as well as financing topics. The topics covered in the district development set included contributions on sustainable (re-)development, the 2000-watt

  14. Contamination source review for Building E3236, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S.D.; Smits, M.P.; Draugelis, A.K.; Glennon, M.A.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from the review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, geophysical investigation, and review of available records regarding underground storage tanks associated with each building. This report provides the results of the contamination source review for Building E3236. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot- scale production of chemical warfare agents and other military substances, the potential exists for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

  15. Contamination source review for Building E2370, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    O`Reilly, D.P.; Glennon, M.A.; Draugelis, A.K.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from this review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, and geophysical investigation. This report provides the results of the contamination source review for Building E2370. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot-scale production of chemical warfare agents and other military substances, the potential exists for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

  16. Reconstruction of Building Outlines in Dense Urban Areas Based on LIDAR Data and Address Points

    Science.gov (United States)

    Jarzabek-Rychard, M.

    2012-07-01

    The paper presents a comprehensive method for automated extraction and delineation of building outlines in densely built-up areas. A novel approach to outline reconstruction is the use of geocoded building address points. They give information about building location thus highly reduce task complexity. Reconstruction process is executed on 3D point clouds acquired by airborne laser scanner. The method consists of three steps: building detection, delineation and contours refinement. The algorithm is tested against a data set that presents the old market town and its surroundings. The results are discussed and evaluated by comparison to reference cadastral data.

  17. Upgrades and Enclosure of Building 15 at Technical Area 40: Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Plimpton, Kathryn D [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garcia, Kari L. M [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brunette, Jeremy Christopher [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McGehee, Ellen D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-15

    The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (Field Office) proposes to upgrade and enclose Building 15 at Technical Area (TA) 40, Los Alamos National Laboratory. Building TA-40-15, a Cold War-era firing site, was determined eligible for listing in the National Register of Historic Places (Register) in DX Division’s Facility Strategic Plan: Consolidation and Revitalization at Technical Areas 6, 8, 9, 14, 15, 22, 36, 39, 40, 60, and 69 (McGehee et al. 2005). Building TA-40-15 was constructed in 1950 to support detonator testing. The firing site will be enclosed by a steel building to create a new indoor facility that will allow for year-round mission capability. Enclosing TA-40-15 will adversely affect the building by altering the characteristics that make it eligible for the Register. In compliance with Section 106 of the National Historic Preservation Act of 1966, as amended, the Field Office is initiating consultation for this proposed undertaking. The Field Office is also requesting concurrence with the use of standard practices to resolve adverse effects as defined in the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos, New Mexico.

  18. The effects of road building on arbuscular mycorrhizal fungal diversity in Huangshan Scenic Area.

    Science.gov (United States)

    Yang, Anna; Tang, Dongmei; Jin, Xiulong; Lu, Lin; Li, Xiaohong; Liu, Kun

    2018-01-22

    Arbuscular mycorrhizal (AM) fungi are vital soil microbes that connect many individual plants into a large functional organism via a vast mycelial network under the ground. In this study, the changes of soil AM fungal community in response to road-building disturbance caused by tourism development in Huangshan (Yellow Mountain) Scenic Area are assessed. Road building have brought negative effects on AM fungal community, inducing lower diversity parameters, including species number, spore density and diversity indices. However, the dominant genus and species of AM fungi which play key roles in the AM fungal community composition are quite similar before and after road building. Moreover, there are no significant differences in species richness of AM fungi associated with plants, suggesting the tolerance of AM fungal community to the disturbance of road building.

  19. Final environmental assessment: TRU waste drum staging building, Technical Area 55, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    1996-01-01

    Much of the US Department of Energy's (DOE's) research on plutonium metallurgy and plutonium processing is performed at Los Alamos National Laboratory (LANL), in Los Alamos, New Mexico. LANL's main facility for plutonium research is the Plutonium Facility, also referred to as Technical Area 55 (TA-55). The main laboratory building for plutonium work within the Plutonium Facility (TA-55) is the Plutonium Facility Building 4, or PF-4. This Environmental Assessment (EA) analyzes the potential environmental effects that would be expected to occur if DOE were to stage sealed containers of transuranic (TRU) and TRU mixed waste in a support building at the Plutonium Facility (TA-55) that is adjacent to PF-4. At present, the waste containers are staged in the basement of PF-4. The proposed project is to convert an existing support structure (Building 185), a prefabricated metal building on a concrete foundation, and operate it as a temporary staging facility for sealed containers of solid TRU and TRU mixed waste. The TRU and TRU mixed wastes would be contained in sealed 55-gallon drums and standard waste boxes as they await approval to be transported to TA-54. The containers would then be transported to a longer term TRU waste storage area at TA-54. The TRU wastes are generated from plutonium operations carried out in PF-4. The drum staging building would also be used to store and prepare for use new, empty TRU waste containers

  20. National Ignition Facility Site Management Plan

    International Nuclear Information System (INIS)

    Roberts, V.

    1997-01-01

    The purpose of the NIF Site Management Plan is to describe the roles, responsibilities, and interfaces for the major NIF Project organizations involved in construction of the facility, installation and acceptance testing of special equipment, and the NIF activation. The plan also describes the resolution of priorities and conflicts. The period covered is from Critical Decision 3 (CD3) through the completion of the Project. The plan is to be applied in a stepped manner. The steps are dependent on different elements of the project being passed from the Conventional Facilities (CF) Construction Manager (CM), to the Special Equipment (SE) CMs, and finally to the Activation/ Start-Up (AS) CM. These steps are defined as follows: The site will be coordinated by CF through Project Milestone 310, end of conventional construction. The site is defined as the fenced area surrounding the facility and the CF laydown and storage areas. The building utilities that are installed by CF will be coordinated by CF through the completion of Project Milestone 310, end of conventional construction. The building utilities are defined as electricity, compressed air, de-ionized water, etc. Upon completion of the CF work, the Optics Assembly Building/Laser and Target Area Building (OAB/LTAB) will be fully operational. At that time, an Inertial Confinement Fusion (ICF) Program building coordinator will become responsible for utilities and site activities. * Step 1. Mid-commissioning (temperature stable, +1 degree C) of an area (e.g., Laser Bay 2, OAB) will precipitate the turnover of that area (within the four walls) from CF to SE. * Step 2. Interior to the turned-over space, SE will manage all interactions, including those necessary by CF. * Step 3. As the SE acceptance testing procedures (ATPS) are completed, AS will take over the management of the area and coordinate all interactions necessary by CF and SE. For each step, the corresponding CMs for CF, SE, or AS will be placed in charge of

  1. National Ignition Facility Site Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, V.

    1997-09-01

    The purpose of the NIF Site Management Plan is to describe the roles, responsibilities, and interfaces for the major NIF Project organizations involved in construction of the facility, installation and acceptance testing of special equipment, and the NIF activation. The plan also describes the resolution of priorities and conflicts. The period covered is from Critical Decision 3 (CD3) through the completion of the Project. The plan is to be applied in a stepped manner. The steps are dependent on different elements of the project being passed from the Conventional Facilities (CF) Construction Manager (CM), to the Special Equipment (SE) CMs, and finally to the Activation/ Start-Up (AS) CM. These steps are defined as follows: The site will be coordinated by CF through Project Milestone 310, end of conventional construction. The site is defined as the fenced area surrounding the facility and the CF laydown and storage areas. The building utilities that are installed by CF will be coordinated by CF through the completion of Project Milestone 310, end of conventional construction. The building utilities are defined as electricity, compressed air, de-ionized water, etc. Upon completion of the CF work, the Optics Assembly Building/Laser and Target Area Building (OAB/LTAB) will be fully operational. At that time, an Inertial Confinement Fusion (ICF) Program building coordinator will become responsible for utilities and site activities. * Step 1. Mid-commissioning (temperature stable, +1{degree}C) of an area (e.g., Laser Bay 2, OAB) will precipitate the turnover of that area (within the four walls) from CF to SE. * Step 2. Interior to the turned-over space, SE will manage all interactions, including those necessary by CF. * Step 3. As the SE acceptance testing procedures (ATPS) are completed, AS will take over the management of the area and coordinate all interactions necessary by CF and SE. For each step, the corresponding CMs for CF, SE, or AS will be placed in charge of

  2. Wind-powered electrical systems : highway rest areas, weigh stations, and team section buildings.

    Science.gov (United States)

    2009-02-01

    This project considered the use of wind for providing electrical power at Illinois Department of Transportation : (IDOT) highway rest areas, weigh stations, and team section buildings. The goal of the project was to determine : the extent to which wi...

  3. Analysis on Zero Energy Consumption Strategy for Office Buildings Lighting in Lianyungang Area

    Science.gov (United States)

    Wu, Dongmei

    2018-01-01

    In recent years, the energy-saving environmental protection has aroused the people’s high concern, and set off a new application practice in China. By analyzing the advantages of the illumination condition in Lianyungang area and combining the content and form of office space, the author puts forward a series of ways and means of energy saving in office building lighting, in order to provide a way for reference to the goal of building Zero energy consumption in the office space environment under the background of green architecture.

  4. EXPERIMENTAL CALIBRATION OF UNDERGROUND HEAT TRANSFER MODELS UNDER A WINERY BUILDING IN A RURAL AREA

    Directory of Open Access Journals (Sweden)

    Francesco Tinti

    2017-01-01

    Full Text Available Ground temperature and hydrogeological conditions are key parameters for many engineering applications, such as the design of building basements and underground spaces and the assessment of shallow geothermal energy potential. Especially in urban areas, in the very shallow depths, it is diffi cult to fi nd natural undisturbed underground thermal conditions because of anthropic interventions. The assessment of underground behaviour in disturbed conditions will become more and more relevant because of increasing awareness to energy effi ciency and renewable energy topics. The purpose of this paper is to show a three-dimensional representation - based on models calibrated on experimental data - of the underground thermal behaviour aff ected by a building in a rural area in Italy. Temperature varies in space and time and it depends on ground, climate and building characteristics, and all these parameters are taken into account by the seasonal periodic modelling implemented. The results obtained in a context of low urbanization indirectly suggest the importance of these eff ects in dense urban areas; taking greater account of these aspects could lead to improvements in the design of underground spaces and geo-exchanger fi elds for geothermal energy exploitation.

  5. A Real-Time Energy Consumption Simulation and Comparison of Buildings in Different Construction Years in the Olympic Central Area in Beijing

    Directory of Open Access Journals (Sweden)

    Chen Xu

    2017-12-01

    Full Text Available Energy consumed the in urban sector accounts for a large proportion of total world delivered energy consumption. Residential building energy consumption is an important part of urban energy consumption. However, there are few studies focused on this issue and that have simulated the energy consumption of residential buildings using questionnaire data. In this research, an eQUEST study was conducted for different residential buildings in the Olympic Central Area in Beijing. Real-time meteorological observation data and an actual energy consumption schedule generated by questionnaire data were used to improve the eQUEST model in the absence of actual energy consumption data. The simulated total energy consumption of residential buildings in the case area in 2015 is 21,262.28 tce, and the average annual energy consumption per unit area is 20.09 kgce/(m2·a. Space heating accounted for 45% of the total energy consumption as the highest proportion, and the second highest was household appliances, which accounted for 20%. The results showed that old residential buildings, multi-storey buildings and large-sized apartment buildings consume more energy. The internal units, building height, per capita construction area, the number of occupants and length of power use had significant impact on residential energy consumption. The result of this study will provide practical reference for energy saving reconstruction of residential buildings in Beijing.

  6. Earthquake disaster simulation of civil infrastructures from tall buildings to urban areas

    CERN Document Server

    Lu, Xinzheng

    2017-01-01

    Based on more than 12 years of systematic investigation on earthquake disaster simulation of civil infrastructures, this book covers the major research outcomes including a number of novel computational models, high performance computing methods and realistic visualization techniques for tall buildings and urban areas, with particular emphasize on collapse prevention and mitigation in extreme earthquakes, earthquake loss evaluation and seismic resilience. Typical engineering applications to several tallest buildings in the world (e.g., the 632 m tall Shanghai Tower and the 528 m tall Z15 Tower) and selected large cities in China (the Beijing Central Business District, Xi'an City, Taiyuan City and Tangshan City) are also introduced to demonstrate the advantages of the proposed computational models and techniques. The high-fidelity computational model developed in this book has proven to be the only feasible option to date for earthquake-induced collapse simulation of supertall buildings that are higher than 50...

  7. Experimental Analyses of Yellow Tuff Spandrels of Post-medieval Buildings in the Naples Area

    International Nuclear Information System (INIS)

    Calderoni, B.; Cordasco, E. A.; Lenza, P.; Guerriero, L.

    2008-01-01

    Experimental analyses have been carried out on tuff masonry specimens in order to investigate the structural behaviour of historical buildings in the Naples area (Southern Italy). Spandrels of post-medieval buildings (late XVI to early XX century) have been analysed, with emphasis on morphological characteristics according to chronological indicators. Results of the experimentation on scaled models (1:10) are discussed and the better behaviour of historical masonry typologies on respect to the modern one is highlighted. Comparison with theoretical formulations of ultimate shear resistance are provided too

  8. Differences in bacterial composition between men's and women's restrooms and other common areas within a public building.

    Science.gov (United States)

    Dobbler, Priscila Caroline Thiago; Laureano, Álvaro Macedo; Sarzi, Deise Schroder; Cañón, Ehidy Rocio Peña; Metz, Geferson Fernando; de Freitas, Anderson Santos; Takagaki, Beatriz Midori; D Oliveira, Cristiane Barbosa; Pylro, Victor Satler; Copetti, André Carlos; Victoria, Filipe; Redmile-Gordon, Marc; Morais, Daniel Kumazawa; Roesch, Luiz Fernando Wurdig

    2018-04-01

    Humans distribute a wide range of microorganisms around building interiors, and some of these are potentially pathogenic. Recent research established that humans are the main drivers of the indoor microbiome and up to now significant literature has been produced about this topic. Here we analyzed differences in bacterial composition between men's and women's restrooms and other common areas within the same public building. Bacterial DNA samples were collected from restrooms and halls of a three-floor building from the Federal University of Pampa, RS, Brazil. The bacterial community was characterized by amplification of the V4 region of the 16S rRNA gene and sequencing. Throughout all samples, the most abundant phylum was Proteobacteria, followed by Actinobacteria, Bacteroidetes and Firmicutes. Beta diversity metrics showed that the structure of the bacterial communities were different among the areas and floors tested, however, only 6-9% of the variation in bacterial communities was explained by the area and floors sampled. A few microorganisms showed significantly differential abundance between men's and women's restrooms, but in general, the bacterial communities from both places were very similar. Finally, significant differences among the microbial community profile from different floors were reported, suggesting that the type of use and occupant demographic within the building may directly influence bacterial dispersion and establishment.

  9. A District Approach to Building Renovation for the Integral Energy Redevelopment of Existing Residential Areas

    Directory of Open Access Journals (Sweden)

    Mira Conci

    2017-05-01

    Full Text Available Building energy renovation quotas are not currently being met due to unfavorable conditions such as complex building regulations, limited investment incentives, historical preservation priorities, and technical limitations. The traditional strategy has been to incrementally lower the energy consumption of the building stock, instead of raising the efficiency of the energy supply through a broader use of renewable sources. This strategy requires an integral redefinition of the approach to energy building renovations. The joint project SWIVT elaborates on a district redevelopment strategy that combines a reduction in the energy demand of existing buildings and their physical interconnection within a local micro-grid and heating network. The district is equipped with energy generation and distribution technologies as well as hybrid thermal and electrical energy storage systems, steered by an optimizing energy management controller. This strategy is explored through three scenarios designed for an existing residential area in Darmstadt, Germany, and benchmarked against measured data. Presented findings show that a total primary energy balance at least 30% lower than that of a standard building renovation can be achieved by a cluster of buildings with different thermal qualities and connected energy generation, conversion, and storage systems, with only minimal physical intervention to existing buildings.

  10. Danish building typologies

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper

    The objective of TABULA is to develop a harmonised building typology for European countries. Each national building typology will consist of a set of residential model buildings with characteristic energy-related properties (element areas of the thermal building envelope, U-values, supply system...... efficiencies). The model buildings will each represent a specific construction period of the country in question and a specific building size. Furthermore the number of buildings, flats and the overall floor areas will be given, which are represented by the different building types of the national typologies....

  11. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  12. Rainfall-induced landslide vulnerability Assessment in urban area reflecting Urban structure and building characteristics

    Science.gov (United States)

    Park, C.; Cho, M.; Lee, D.

    2017-12-01

    Landslide vulnerability assessment methodology of urban area is proposed with urban structure and building charateristics which can consider total damage cost of climate impacts. We used probabilistic analysis method for modeling rainfall-induced shallow landslide susceptibility by slope stability analysis and Monte Carlo simulations. And We combined debris flows with considering spatial movements under topographical condition and built environmental condition. Urban vulnerability of landslide is assessed by two categories: physical demages and urban structure aspect. Physical vulnerability is related to buildings, road, other ubran infra. Urban structure vulnerability is considered a function of the socio-economic factors, trigger factor of secondary damage, and preparedness level of the local government. An index-based model is developed to evaluate the life and indirect damage under landslide as well as the resilience ability against disasters. The analysis was performed in a geographic information system (GIS) environment because GIS can deal efficiently with a large volume of spatial data. The results of the landslide susceptibility assessment were compared with the landslide inventory, and the proposed approach demonstrated good predictive performance. The general trend found in this study indicates that the higher population density areas under a weaker fiscal condition that are located at the downstream of mountainous areas are more vulnerable than the areas in opposite conditions.

  13. Low-energy district heating in energy-efficient building areas

    International Nuclear Information System (INIS)

    Dalla Rosa, A.; Christensen, J.E.

    2011-01-01

    This paper presents an innovative low-energy district heating (DH) concept based on low-temperature operation. The decreased heating demand from low-energy buildings affects the cost-effectiveness of traditionally-designed DH systems, so we carried out a case study of the annual energy performance of a low-energy network for low-energy houses in Denmark. We took into account the effect of human behaviour on energy demand, the effect of the number of buildings connected to the network, a socio-economic comparison with ground source heat pumps, and opportunities for the optimization of the network design, and operational temperature and pressure. In the north-European climate, we found that human behaviour can lead to 50% higher heating demand and 60% higher heating power than those anticipated in the reference values in the standard calculations for energy demand patterns in energy-efficient buildings. This considerable impact of human behaviour should clearly be included in energy simulations. We also showed that low-energy DH systems are robust systems that ensure security of supply for each customer in a cost-effective and environmentally friendly way in areas with linear heat density down to 0.20 MWh/(m year), and that the levelized cost of energy in low-energy DH supply is competitive with a scenario based on ground source heat pumps. The investment costs represent up to three quarters of the overall expenditure, over a time horizon of 30 years; so, the implementation of an energy system that fully relies on renewable energy needs substantial capital investment, but in the long term this is sustainable from the environmental and socio-economic points of view. Having demonstrated the value of the low-energy DH concept, we evaluated various possible designs with the aim of finding the optimal solution with regard to economic and energy efficiency issues. Here we showed the advantage of low supply and return temperatures, their effect on energy efficiency and that

  14. 300 Area D4 Project 2nd Quarter FY06 Building Completion Report

    International Nuclear Information System (INIS)

    Smith, David S.

    2006-01-01

    This report documents the deactivation, decontamination, decommissioning, and demolition of 16 buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation as appropriate.

  15. Thermal and Economic Analysis of Renovation Strategies for a Historic Building in Mediterranean Area

    Directory of Open Access Journals (Sweden)

    Simona Cirami

    2017-07-01

    Full Text Available Around 30% of the European building stock was built before 1950, when no regulations about energy efficiency were in force. Since only a small part of them has been renovated by now, the energy performance of this building stock is on average quite poor, resulting in a significant impact on the energy balance of European countries, as confirmed by data published by ISTAT (Italian National Statistical Institute. However, energy retrofit in historic edifices is a quite demanding issue as any intervention must take into account the need to preserve existing building materials and appearances while also allowing reversibility and low invasiveness. As an example, in these buildings it is not possible to apply an ETICS (External Thermal Insulation Composite System, since this would alter the historic and architectural value of the façade. On the other hand, internal insulation would have the drawback of reducing the net useful floor area, which also implies a loss of economic value. Moreover, internal insulation may induce overheating risks and mold formation. In this paper, all these issues are investigated with reference to an existing historic building located in southern Italy, showing that a retrofit strategy aimed at energy savings and cost-effectiveness is still possible if suitable materials and solutions are adopted.

  16. Technology line and case analysis of heat metering and energy efficiency retrofit of existing residential buildings in Northern heating areas of China

    International Nuclear Information System (INIS)

    Zhao Jing; Zhu Neng; Wu Yong

    2009-01-01

    The building area in northern heating areas accounting for 70% of the total land area in China is 6,500,000,000 m 2 . The average heating energy consumption in northern China is 100-200% times more than developed countries in the same latitude. This paper introduced firstly the heat metering and energy efficiency retrofit background of existing residential buildings in northern heating areas of China organized by mohurd and MOF, and then put forward the total principle and contents of retrofit. Through analyzing some retrofit cases in Germany, Poland and China, some technological experiences were summarized and finally a technology line suitable for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China which involved retrofit for heat metering and temperature regulation of heating systems, heat balance of heat source and network, and building envelope was described to provide a systematic, scientific, technological guide for the retrofit projects of 0.15 billion m 2 in 'the Eleventh Five-Year Plan' period.

  17. Optimal choice: assessing the probability of additional damage to buildings caused by water level changes of larger areas

    Science.gov (United States)

    Bijnagte, J. L.; Luger, D.

    2012-12-01

    In the Northern parts of the Netherlands exploration of natural gas reservoirs causes subsidence over large areas. As a consequence, the water levels in canals and polders have to be adjusted over time in order to keep the groundwater levels at a constant depth relative to the surface level. In the middle of the subsidence area it is relatively easy to follow the settlements by a uniform lowering of the water level. This would however result in a relative lowering of the groundwater table at the edges of the subsidence area. Given the presence of soft compressible soils, this would result in induced settlements. For buildings in these areas this will increase the chance of damage. A major design challenge lies therefore in the optimisation of the use of compartments. The more compartments the higher the cost therefore the aim is to make compartments in the water management system that are as large as possible without causing inadmissible damage to buildings. In order to asses expected damage from different use of compartments three tools are needed. The first is a generally accepted method of damage determination, the second a method to determine the contribution to damage of a new influence, e.g. a groundwater table change. Third, and perhaps most importantly, a method is needed to evaluate effects not for single buildings but for larger areas. The first need is covered by established damage criteria like those of Burland & Wroth or Boscardin & Cording. Up until now the second and the third have been problematic. This paper presents a method which enables to assign a contribution to the probability of damage of various recognised mechanisms such as soil and foundation inhomogeneity, uneven loading, ground water level changes. Shallow subsidence due to peat oxidation and deep subsidence due to reservoir depletion can be combined. In order to address the third issue: evaluation of effects for larger areas, the method uses a probabilistic approach. Apart from a

  18. Introduction of building vibration observation data of metropolitan area due to the 2011 off the Pacific coast of Tohoku Earthquake: an Approach of the IT Kyoshin Seismometer for Buildings

    Science.gov (United States)

    Takano, K.; Ito, T.

    2011-12-01

    In the 2011 off the Pacific coast of Tohoku Earthquake, many buildings were vibrated greatly also in the Tokyo metropolitan area where is far left from the hypocenter. We have developed the IT Kyoshin(strong motion) Seismometer for Building which is the observation system of the usual weak earthquake ground motion by installing a lot of acceleration sensors in building, and have been setting it up in some buildings of the University of Tokyo. By this February, we have set up IT Kyoshin Seismometers newly in four buildings of the two remote campus of the University of Tokyo. And we have opend to the public of these observed data. In this building vibration observation system, we can get a lot of building vibration observation data of the Pacific coast of Tohoku Earthquake. We have made the building shaking to visible from the observation data of each building and the appearance of the shake of each building is shown plainly. Moreover, we can see how the vibration property in the usual building is changed by the large shaking. This analysis of the observation data of the building vibration at the earthquake is useful for the detection of the damaged part in the building by the earthquake and for the reinforcement measures in the weak buildings.

  19. Estimation of solar collector area for water heating in buildings of Malaysia

    Science.gov (United States)

    Manoj Kumar, Nallapaneni; Sudhakar, K.; Samykano, M.

    2018-04-01

    Solar thermal energy (STE) utilization for water heating at various sectorial levels became popular and still growing especially for buildings in the residential area. This paper aims to study and identify the solar collector area needed based on the user requirements in an efficient manner. A step by step mathematical approach is followed to estimate the area in Sq. m. Four different cases each having different hot water temperatures (45°, 50°C, 55°C, and 60°C) delivered by the solar water heating system (SWHS) for typical residential application at Kuala Lumpur City, Malaysia is analysed for the share of hot and cold water mix. As the hot water temperature levels increased the share of cold water mix is increased to satisfy the user requirement temperature, i.e. 40°C. It is also observed that as the share of hot water mix is reduced, the collector area can also be reduced. Following this methodology at the installation stage would help both the user and installers in the effective use of the solar resource.

  20. Building a Higher Education Area in Central Asia: challenges and prospects

    Directory of Open Access Journals (Sweden)

    Ann Katherine Isaacs

    2014-12-01

    Full Text Available In recent years, for a variety of reasons, higher education has begun to be considered much more frequently than previously in terms of ‘regions’, or ‘macro-regions’. Although for decades countries sharing some characteristics, or perceived as geographically or culturally closely related to each other, have promoted forms of cooperation between their higher education institutions (with varying degrees of success, it is now widely accepted that to ‘count’ on the world stage, it is useful for single countries, and especially for smaller countries, to work together with a view to making their systems better able to interact and hopefully to promote, increase and make visible their merits. Of course, in higher education as in many other fields, the regions or macro-regions are not defined once and for all, but are the result of stronger or weaker ad hoc groupings which take into account different factors in different contexts. Central Asia is one such potential region: it does not have unquestioned boundaries, but like other macro-regions, and more so than most, it can be understood and constructed in different ways. A current shared understanding of ‘Central Asia’ is that it is formed by the 4 ex-Soviet Republics of Central Asia (Kyrgyzstan, Tajikistan, Turkmenistan and Uzbekistan, plus Kazakhstan. Over the last decade the possibility of building a Higher Education Area in those five republics has been explored, and a large-scale project which uses Tuning methodology to this end is under way. This project, called TuCAHEA (“Towards a Central Asian Higher Education Area: Tuning Structures and Building Quality Culture”, has already elaborated a Central Asian list of Generic Competences and eight Subject Area Groups have formulated their Reference Points and Guidelines. The five Ministries of the five countries have signed a Communiqué indicating their intention to collaborate more closely; a pilot student mobility scheme is soon

  1. Innovative technologies of outsourcing at the machine-building enterprises of Sverdlovsk area

    OpenAIRE

    Petr Krylatkov

    2010-01-01

    The analysis of the basic problems connected with infringements of integrity of the machine-building enterprises of Sverdlovsk area is lead in the article. The specified problems are considered from a position of the complete approach developed by the author. Display of infringements of integrity of some the enterprises are illustrated by data of their inspection. As the effective tool of increase of integrity of the enterprises — expansion use of attitudes of outsourcing is offered. The co...

  2. 300 Area D4 Project 3rd Quarter Fiscal Year 2006 Building Completion Report

    International Nuclear Information System (INIS)

    Smith, D.S.

    2006-01-01

    This report documents the deactivation, decontamination, decommissioning, and demolition of five buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation as appropriate.

  3. Derived concentration guideline levels for Argonne National Laboratory's building 310 area.

    Energy Technology Data Exchange (ETDEWEB)

    Kamboj, S., Dr.; Yu, C ., Dr. (Environmental Science Division)

    2011-08-12

    The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.

  4. Courthouse Prototype Building

    Energy Technology Data Exchange (ETDEWEB)

    Malhotra, Mini [ORNL; New, Joshua Ryan [ORNL; Im, Piljae [ORNL

    2018-02-01

    As part of DOE's support of ANSI/ASHRAE/IES Standard 90.1 and IECC, researchers at Pacific Northwest National Laboratory (PNNL) apply a suite of prototype buildings covering 80% of the commercial building floor area in the U.S. for new construction. Efforts have started on expanding the prototype building suite to cover 90% of the commercial building floor area in the U.S., by developing prototype models for additional building types including place of worship, public order and safety, public assembly. Courthouse is courthouse is a sub-category under the “Public Order and Safety" building type category; other sub-categories include police station, fire station, and jail, reformatory or penitentiary.ORNL used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents the research conducted for the courthouse building type and proposes building and system characteristics for developing a prototype building energy model to be included in the Commercial Building Prototype Model suite. According to the 2012 CBECS, courthouses occupy a total of 436 million sqft of floor space or 0.5% of the total floor space in all commercial buildings in the US, next to fast food (0.35%), grocery store or food market (0.88%), and restaurant or cafeteria (1.2%) building types currently included in the Commercial Prototype Building Model suite. Considering aggregated average, courthouse falls among the larger with a mean floor area of 69,400 sqft smaller fuel consumption intensity building types and an average of 94.7 kBtu/sqft compared to 77.8 kBtu/sqft for office and 80 kBtu/sqft for all commercial buildings.Courthouses range in size from 1000 sqft to over a million square foot building gross square feet and 1 courtroom to over 100 courtrooms. Small courthouses

  5. Hitchcock-happening friikluse võtmes / Jarmo Valkola

    Index Scriptorium Estoniae

    Valkola, Jarmo

    2008-01-01

    Alfred Hitchcockist seoses uue filmisarjaga "Ainult friikidele". Sarja juhatab sisse Balti Filmi- ja Meediakooli (BFMi) Hitchcocki seminar 26.-29. veebruaril Tallinna Kinomajas. Lisatud kava. (Filmisari linastub alates 25. veebruarist igal teisel esmaspäeval kinos Sõprus ja teisipäeval Tartu Athena Keskuses. Programm vältab ligi kuus kuud, 29. juulini. Esimese hooaja teemaks on ühiskondlikud ebakõlad)

  6. The Evaluation of Facilitation Process in Building Community Capacity about OVOP Concept in Kenjeran Coastal Area, Surabaya

    Science.gov (United States)

    Handayeni, K. D. M. E.; Santoso, E. B.; Siswanto, V. K.

    2017-07-01

    The concept of One Village One Product (OVOP) is an approach to the development potential of the area in the region to produce products that can compete in the global market, while still having unique characteristics of the area. Bulak District is one of the Kenjeran coastal area in Surabaya, Indonesia. Bulak District has had a great potential of marine products, but still contribute greatly in improving the people's welfare. Total activities of SMEs in the District of Bulak quite a lot, but the resulting product unknown to the wider community and the global marketplace. Activity of facilitation for SMEs society do to build community capacity in the implementation of the concept of OVOP. Based on the results of the evaluation assistance through Wilcoxon Signed Ranks Test result an increased understanding of the community regarding to the five subjects related OVOP concept. There are six factors to note in mentoring activities that need to be considered for the sustainability of community capacity building programs on OVOP.

  7. 300 Area D4 Project 4th Quarter Fiscal Year 2006 Building Completion Report

    International Nuclear Information System (INIS)

    D. S. Smith

    2007-01-01

    This report documents the deactivation, decontamination, decommissioning, and demolition (D4) of nine buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation, as appropriate

  8. An Algorithm of Building Extraction in Urban Area Based on Improved Top-hat Transformations and LBP Elevation Texture

    Directory of Open Access Journals (Sweden)

    HE Manyun

    2017-09-01

    Full Text Available Classification of building and vegetation is difficult solely by LiDAR data and vegetation in shadows can't be eliminated only by aerial images. The improved top-hat transformations and local binary patterns (LBP elevation texture analysis for building extraction are proposed based on the fusion of aerial images and LiDAR data. Firstly, LiDAR data is reorganized into grid cell, the algorithm removes ground points through top-hat transform. Then, the vegetation points are extracted by normalized difference vegetation index (NDVI. Thirdly, according to the elevation information of LiDAR points, LBP elevation texture is calculated and achieving precise elimination of vegetation in shadows or surrounding to the buildings. At last, morphological operations are used to fill the holes of building roofs, and region growing for complete building edges. The simulation is based on the complex urban area in Vaihingen benchmark provided by ISPRS, the results show that the algorithm affording higher classification accuracy.

  9. Sustainable Development of Heritage Areas: Towards Cyber-Physical Systems Integration in Extant Heritage Buildings and Planning Conservation

    Directory of Open Access Journals (Sweden)

    Laila Mohamed Khodeir

    2017-03-01

    Full Text Available Although architectural heritage reflects the evolution of human civilization throughout history, nevertheless, civilized and social changes of heritage areas in many countries led to their degradation. Historical building management and planning conservation raise two important issues: the restoration and improvement of historical areas features and adopting a framework of sustainable development in heritage regions. Recently a number of processes have arose to aid in the aforementioned problems, namely the heritage building information modelling (HBIM and the  cyber-physical systems approach (CPS, where the latter is believed to  achieve great potentials hereby integrating virtual models and physical construction and  enabling bidirectional coordination. Since HBIM has recently been investigated through a number of recent research and application, the aim of this paper is to explore the potentials offered by the CPS, to move from 3D content model to bi-dimensional coordination for achieving efficient management of built heritage. To tackle the objective of this paper, firstly, a review of the BIM use in the field of cultural heritage  was undergone, Secondly, reporting the existing BIM/HBIM platforms, analyzing cyber-physical systems integration in extant heritage buildings and in planning conservation were performed. Results of this paper took the form of detailed comparative analysis between both CPS and HBIM, which could guide decision makers working in the field of heritage buildings management, in addition to shedding light on the main potentials of the emerging CPS.

  10. Bioinjection Performance Review for the Building 100 Area and 4.5 Acre Site at the Pinellas County, Florida, Site

    Energy Technology Data Exchange (ETDEWEB)

    Survochak, Scott [US Department of Energy, Washington, DC (United States). Office of Legacy Management; Daniel, Joe [Navarro Research and Engineering, Oak Ridge, TN (United States)

    2016-05-01

    This document provides a summary of a review of the performance of bioinjection activities at the Building 100 Area and the 4.5 Acre Site at the Pinellas County, Florida, Site since 2010, determines how best to optimize future injection events, and identifies the approach for the bioinjection event in 2016 at (1) the 4.5 Acre Site and (2) the Essentra property at the Building 100 Area. Because this document describes the next bioinjection event at the 4.5 Acre Site, it also serves as an addendum to the Interim Remedial Action Plan for Emulsified Edible Oil Injection at the 4.5 Acre Site (DOE 2013). In addition, this document revises the injection layout and injection intervals for the Essentra property that were originally described in the Interim Corrective Measure Work Plan for Source and Plume Treatment at the Building 100 Area (DOE 2014), and is a de facto update of that document. Bioinjection consists of injection of emulsified vegetable oil (EVO) and the microorganism Dehalococcoides mccartyi (DHM; formerly known as Dehalococcoides ethenogenes) into the subsurface to enhance biodegradation of trichloroethene (TCE), dichloroethene (DCE), and vinyl chloride (VC). VC is the only contaminant that exceeds its maximum contaminant level (10 micrograms per liter onsite and 1 microgram per liter onsite) on the 4.5 Acre Site and the Essentra property. Bioinjection was conducted at the 4.5 Acre Site in 2010 and 2013. Approximately 49,900 gallons of EVO and DHM were injected at 95 injection points in February 2010, and approximately 22,900 gallons of EVO and DHM were injected at 46 injection points in July 2013. The injection locations are shown on Figure 1. The goal of bioinjection at the 4.5 Acre Site is to decrease contaminant concentrations to maximum contaminant levels along the west and southwest property boundaries (to meet risk–based corrective action requirements) and to minimize the extent of the contaminant plume in the interior of the site. Bioinjection was

  11. Innovative technologies of outsourcing at the machine-building enterprises of Sverdlovsk area

    Directory of Open Access Journals (Sweden)

    P. P. Krylatkov

    2010-09-01

    Full Text Available The analysis of the basic problems connected with infringements of integrity of the machine-building enterprises of Sverdlovsk area is lead in the article. The specified problems are considered from a position of the complete approach developed by the author. Display of infringements of integrity of some the enterprises are illustrated by data of their inspection. As the effective tool of increase of integrity of the enterprises — expansion use of attitudes of outsourcing is offered. The comparative given applications of outsourcing in developed the country of the West and at the domestic enterprises, and also its benefits and risks are cited. Outsourcing, insoursing and subcontracting are considered by the author as the innovative tool of the decision of many serious problems of the machine-building enterprises of region. As an example practice of work of «The Sverdlovsk regional center of industrial cooperation» on coordination of attitudes of outsourcing, subcontracting and cooperation is offered. The author recommends the tabulated form, with the instruction of kinds of works for which performance the method of allocation or attraction outsourcing of the companies can be used.

  12. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1993-01-01

    In both nuclear and non-nuclear areas of power plants, sections of structures, parts of systems and components are attached to walls and floors by means of anchor plates with bolts, anchor sleeves and bolts and through bolts arranged either in groups or individually. In order to simplify the determination of the transfered vibrations induced by external events (e.g. earthquake, aircraft crash), it is normally assumed that the nodal point between component and concrete possesses rigid body characteristics and the building structure (walls, floors) is also inflexible in the anchorage area. In the course of the parametric studies performed, the nonlinear effects on the anchorage area of a component (in this case an anchor plate and concrete slab) were calculated and the effect of these on the actual vibration behavior and the local structural responses of the building structure at the place of installation of heavy components were investigated. The investigations performed reveal that by taking into account the local behaviour in the anchoring point, it is possible to reduce the dynamic response considerably. More detailed examination of the influence of additional parameters (especially of the geometry of the anchor plates and anchor bolts and their material characteristics) will require further investigations aimed at establishing the characteristics of typical anchor plates. (orig.)

  13. Gamma-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao; Sakaki, Hironao; Nishiyama, Koichi

    2013-01-01

    Highlights: • Area monitoring system and control system are needed for LIPAc radiation management. • To secure the radiation safety, these systems are linked with two kinds of data path. • Hardwired data paths are adopted to realize the fast transfer of interlock signals. • Dual LAN and shared memory are adopted to the reliable transfer of monitoring data. • Data transfers without unnecessary load are designed and configured for these systems. -- Abstract: The linear IFMIF prototype accelerator (LIPAc) produces deuteron beam with 1 MW power. Since huge number of neutrons occur from such a high power beam, therefore, it is important for the radiation management to design a high reliability area monitoring system for gamma-rays and neutrons. To obtain the valuable operation data of the high-power deuteron beam at LIPAc, it is important to link and record the beam operation data and the area monitoring data. We realize the reliable data transfer to provide the area monitoring data to the accelerator control system which needs a high reliability using the shared-memory data link method. This paper describes the area monitoring system in the LIPAc building and the data-link between this system and the LIPAc control system

  14. Evaluation of building fundamental periods and effects of local geology on ground motion parameters in the Siracusa area, Italy

    Science.gov (United States)

    Panzera, Francesco; D'Amico, Sebastiano; Lombardo, Giuseppe; Longo, Emanuela

    2016-07-01

    The Siracusa area, located in the southeastern coast of Sicily (Italy), is mainly characterized by the outcropping of a limestone formation. This lithotype, which is overlain by soft sediments such as sandy clays and detritus, can be considered as the local bedrock. Records of ambient noise, processed through spectral ratio techniques, were used to assess the dynamic properties of a sample survey of both reinforced concrete and masonry buildings. The results show that experimental periods of existing buildings are always lower than those proposed by the European seismic code. This disagreement could be related to the role played by stiff masonry infills, as well as the influence of adjacent buildings, especially in downtown Siracusa. Numerical modeling was also used to study the effect of local geology on the seismic site response of the Siracusa area. Seismic urban scenarios were simulated considering a moderate magnitude earthquake (December 13th, 1990) to assess the shaking level of the different outcropping formations. Spectral acceleration at different periods, peak ground acceleration, and velocity were obtained through a stochastic approach adopting an extended source model code. Seismic ground motion scenario highlighted that amplification mainly occurs in the sedimentary deposits that are widespread to the south of the study area as well as on some spot areas where coarse detritus and sandy clay outcrop. On the other hand, the level of shaking appears moderate in all zones with outcropping limestone and volcanics.

  15. Engineering evaluation cost analysis for the 100-B/C area ancillary facilities at the 108-F Building

    International Nuclear Information System (INIS)

    1996-10-01

    In 1995, the US Department of Energy (DOE), Richland Operations Office (RL) conducted a removal site evaluation of selected facilities in the 100 Area of the Hanford Site in accordance with CERCLA and 40 Code of Federal Regulations (CFR) 300.410. The scope of the evaluation included the aboveground portions of the 108-F Biology Laboratory in the 100-F Area and all inactive ancillary buildings and structures in the 100-B/C Area, excluding the reactor building and the river outfall. Based on the evaluation, RL determined that hazardous substances in the 108-F Biology Laboratory and five of the 100-B/C Area facilities may present a potential threat to human health or the environment, and that a non-time critical removal action at these facilities is warranted. This determination was documented in an engineering evaluation/cost analysis (EE/CA) approval memorandum. The EE/CA approval memorandum is the basis on which to proceed with the performance of an EE/CA to determine the appropriate removal action. This report presents the results of the EE/CA for removal alternatives for final disposition of these six facilities. The EE/CA was conducted pursuant to the requirements of CERCLA and 40 CFR 300.415 and is intended to aid RL and the EPA in selecting a preferred removal action

  16. Assessing the Land Subsidence Governance in Ningbo City: By a Close Study of the Building Collapse at the Strictly Protected Land Subsidence Area

    Science.gov (United States)

    Yu, Xia

    2016-04-01

    Ningbo is a coastal city in East China, its land subsidence problem was noticed in the 1960s. However, scientific management was insufficient at that time, so with the fast city development from the 1980s, groundwater was used by a large amount of small factories, and tall buildings were built on the land. It was in 2008, scientists predicted that if without doing anything to prevent the land from subsiding, the city will be covered by the East Sea in 2030. From then on, the local government implied several policies, such as shut down most of the groundwater pumping wells, set up a new authority to enhance the cooperation among different administration departments, and also set up a land subsidence monitoring center for the city. Recently, it is declared that a Stereo regulatory system of land subsidence governance has been achieved. However, in 2012, a 23-years old building in the city center collapsed. According to the City Planning 2009, this building is located just in the strictly protected land subsidence area. The experts, however, think that land subsidence is not the main reason, since there are many illegal changes to the building during the past 23 years. The aim of my research is to assess the land subsidence governance in Ningbo city. I studied the collapsed building, how it was built, what has changed after building, how the environment changed in this area, and how this area became the strictly protected land subsidence area, and what kind of protections have been made. Actually, during the case study I discuss the land subsidence governance design of Ningbo, and to see what practices and lessons we can learn from this case.

  17. Radon Protection in the Technical Building Code

    International Nuclear Information System (INIS)

    Frutos, B.; Garcia, J. P.; Martin, J. L.; Olaya, M.; Serrano, J I.; Suarez, E.; Fernandez, J. A.; Rodrigo, F.

    2003-01-01

    Building construction in areas with high radon gas contamination in land requires the incorporation of certain measures in order to prevent the accumulation of this gas on the inside of buildings. These measures should be considered primarily in the design and construction phases and should take the area of the country into consideration where the construction will take place depending on the potential risk of radon entrance. Within the Technical Building Code, radon protection has been considered through general classification of the country and specific areas where building construction is to take place, in different risk categories and in the introduction of building techniques appropriate for each area. (Author) 17 refs

  18. Measures taken by the building authorities in order to reduce radiation risks in buildings

    International Nuclear Information System (INIS)

    Tell, Wilhelm

    1980-01-01

    The Swedish radon commission has recommended that the risk of radiation and radon emission from the ground be considered when planning for new settlements, building materials with high radioactivity not be allowed for new buildings, and existing buildings with high levels of radioactivity be traced and improved. Maps of gamma radiation from the ground are being worked out showing areas with levels higher than 30 μR/h. Within such areas buildings should be planned taking the ultimate limits for new buildings into account. Building permits are granted for construction of new structures or extensive renovations if it can be shown that radiation levels within the buildings will be within legal limits: 70 Bq/m 3 for new buildings and 200 Bq/m 3 for existing ones. The radon commission has suggested that buildings with a radon daughter concentration exceeding 400 Bq/m 3 should be found and levels reduced to 200 Bq/m 3

  19. Building energy analysis of Electrical Engineering Building from DesignBuilder tool: calibration and simulations

    Science.gov (United States)

    Cárdenas, J.; Osma, G.; Caicedo, C.; Torres, A.; Sánchez, S.; Ordóñez, G.

    2016-07-01

    This research shows the energy analysis of the Electrical Engineering Building, located on campus of the Industrial University of Santander in Bucaramanga - Colombia. This building is a green pilot for analysing energy saving strategies such as solar pipes, green roof, daylighting, and automation, among others. Energy analysis was performed by means of DesignBuilder software from virtual model of the building. Several variables were analysed such as air temperature, relative humidity, air velocity, daylighting, and energy consumption. According to two criteria, thermal load and energy consumption, critical areas were defined. The calibration and validation process of the virtual model was done obtaining error below 5% in comparison with measured values. The simulations show that the average indoor temperature in the critical areas of the building was 27°C, whilst relative humidity reached values near to 70% per year. The most critical discomfort conditions were found in the area of the greatest concentration of people, which has an average annual temperature of 30°C. Solar pipes can increase 33% daylight levels into the areas located on the upper floors of the building. In the case of the green roofs, the simulated results show that these reduces of nearly 31% of the internal heat gains through the roof, as well as a decrease in energy consumption related to air conditioning of 5% for some areas on the fourth and fifth floor. The estimated energy consumption of the building was 69 283 kWh per year.

  20. Resource Conservation and Recovery Act industrial site environmental restoration site characterization plan: Area 23, Building 650 Leachfield

    International Nuclear Information System (INIS)

    1997-03-01

    This plan presents the strategy for the characterization of Corrective Action Unit 94, Area 23, Building 650 Leachfield. It is a land disposal unit, located southeast of Building 650, that was in operation from 1965 to October 1992, with an estimated annual discharge rate of less than 984 liters from designated sinks, floor drains, and emergency decontamination showers in Building 650. The objectives of the planned activities are to: obtain sufficient sample analytical data from which further assessment, remediation, and/or closure strategies may be developed for the site: and obtain sufficient sample analytical data for management of investigation-derived waste (IDW). All references to regulations in this plan are to the versions of the regulations that are current at the time of publication of this plan. The scope of the characterization will include subsurface soil boring (i.e., drilling), in situ sampling of the soil within subsurface soil borings, and sample analysis for both site characterization and waste management purposes

  1. Development of safety enhancement technology of containment building

    International Nuclear Information System (INIS)

    Seo, Jeong Moon; Choun, Y. S.; Choi, I. K.

    2002-04-01

    This study consists of four research areas, (1) Seismic safety assessment, (2) Aging assessment of a containment building, (3) Prediction of long-term behavior and analysis of a containment building, (4) Performance verification of a containment building. In the seismic safety assessment area, responses of a containment building were monitored and the analysis method was verified. Also performed are the identification of earthquake characteristics and improvement of the seismic fragility analysis method. In the area of aging assessment of a containment building, we developed aging management code SLMS and database. Aging tests were performed for containment building materials and aging models were developed. Techniques for investigation, detection, and evaluation of aging were developed. In the area of prediction of long-term behavior and analysis of a containment building, we developed a non-linear structural analysis code NUCAS and material models. In the area of performance verification of a containment building, we analyzed the crack behavior of a containment wall and the behavior of the containment under internal pressure. We also improved the ISI methods for prestressed containment

  2. Building integration of PCM for natural cooling of buildings

    International Nuclear Information System (INIS)

    Álvarez, Servando; Cabeza, Luisa F.; Ruiz-Pardo, Alvaro; Castell, Albert; Tenorio, José Antonio

    2013-01-01

    Highlights: ► A brief overview of PCM solutions for buildings is provided. ► Some weaknesses of existing PCM solutions for buildings were identified. ► New solutions for PCM integration in buildings are proposed. ► Proposed solutions overcome identified weaknesses of existing solutions. - Abstract: The use of night cooling ventilation in addition of phase change materials (PCMs) is a very powerful strategy for reducing the cooling demand of buildings. Nevertheless, there are inherent drawbacks in the way things have been doing so far: (a) The limited area of contact between PCM and the air; (b) the very low convective heat transfer coefficients which prevents the use of significant amounts of PCM and (c) the very low utilization factor of the cool stored due to the large phase shift between the time when cool is stored and time when it is required by the building. In this paper, we present innovative solutions using PCM to overcome the above situation. Compared with existing solutions, innovative solutions proposed, increase the contact area between PCM and air by a factor of approximately 3.6, increase the convective heat transfer coefficient significantly, and improve the utilization factor due to the inclusion of active control systems which allow the cold stored be actually used when required

  3. An evaluation of the effectiveness of the UK programme to protect new buildings in radon affected areas

    International Nuclear Information System (INIS)

    Denman, A.R.; Fraser, J.; Phillips, P.S.

    2000-01-01

    The discovery of areas in the UK with significant indoor radon levels prompted the Building Research Establishment in 1992 to publish guidance (1) specifying protection measures, enforced by law, when building new houses in radon Affected Areas. In high risk areas, with over 10% of existing houses above the 200 Bq m -3 Action Level, primary protection in the form of a radon-proof membrane is required, as well as secondary protection in the form of a sump capable of being fitted with a low cost pump. In lower risk areas with 3 to 10% of houses above the Action Level only secondary protection is specified. This latter requirement reduces the cost of providing radon remediation to around pound 150 for the fan, rather than an average of pound 750 for providing a sump and fitting a fan, but requires measurement of the radon level to judge whether remediation is required. Northamptonshire, with 6.3% of houses above the Action Level, has areas of both high and lower risk. There has been considerable influx of population in recent years, with 12,200 new houses built since 1993. In high risk areas in Northamptonshire, the collective dose reduction of primary protection has been calculated and has now reached 23 man-sieverts per year has been avoided in the total of 7,900 houses built since 1993. Using current NRPB risk estimates this is equivalent to 0.8 lung cancers avoided each year. This is similar to that achieved by the remediation programme in existing housing, although the potential saving in existing housing is much greater if more householders can be encouraged to carry out remediation (2). In addition, two new housing estates in the lower risk area have been assessed by issuing 6-day etched track detectors to householders, and using a questionnaire to assess their knowledge of radon. Two detectors were used, one in the living area and bedroom, and results were combined using the NRPB protocol to give a weighted seasonally corrected average radon level. In one

  4. Analysis of building deformation in landslide area using multisensor PSInSAR™ technique.

    Science.gov (United States)

    Ciampalini, Andrea; Bardi, Federica; Bianchini, Silvia; Frodella, William; Del Ventisette, Chiara; Moretti, Sandro; Casagli, Nicola

    2014-12-01

    Buildings are sensitive to movements caused by ground deformation. The mapping both of spatial and temporal distribution, and of the degree of building damages represents a useful tool in order to understand the landslide evolution, magnitude and stress distribution. The high spatial resolution of space-borne SAR interferometry can be used to monitor displacements related to building deformations. In particular, PSInSAR technique is used to map and monitor ground deformation with millimeter accuracy. The usefulness of the above mentioned methods was evaluated in San Fratello municipality (Sicily, Italy), which was historically affected by landslides: the most recent one occurred on 14th February 2010. PSInSAR data collected by ERS 1/2, ENVISAT, RADARSAT-1 were used to study the building deformation velocities before the 2010 landslide. The X-band sensors COSMO-SkyMed and TerraSAR-X were used in order to monitor the building deformation after this event. During 2013, after accurate field inspection on buildings and structures, damage assessment map of San Fratello were created and then compared to the building deformation velocity maps. The most interesting results were obtained by the comparison between the building deformation velocity map obtained through COSMO-SkyMed and the damage assessment map. This approach can be profitably used by local and Civil Protection Authorities to manage the post-event phase and evaluate the residual risks.

  5. Suitability assessment of building energy saving technologies for office buildings in cold areas of China based on an assessment framework

    International Nuclear Information System (INIS)

    Geng, Geng; Wang, Zhaoxia; Zhao, Jing; Zhu, Neng

    2015-01-01

    Highlights: • An assessment method considering economy, environment and technology is proposed. • Office buildings are classified into 3 types and weights are calculated respectively. • BESTs were summed up as 3 suitability levels. • Recommendations are proposed for adopting in design stage. - Abstract: Blind application and extensive copy of building energy saving technologies have been found very common through investigation in China. Emphases should be put on the suitability assessment when selecting and optimizing building energy saving technologies. This paper created an assessment method, namely an assessment framework to assess the suitability level of building energy saving technologies from a holistic point of view. Fuzzy analytic hierarchy process was adopted. 3 factors and 8 sub-factors were included in the framework. The office buildings were classified into 3 types to calculate weights of factors and sub-factors. The assessment framework was established for each type of office buildings. 20 energy saving technologies from surveyed cases was selected as case study. Ranks of suitability level of the assessment objects were obtained for each type of office buildings. The assessment results could be referred when selecting building energy saving technologies in the design stage

  6. 10 CFR 434.520 - Speculative buildings.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Speculative buildings. 434.520 Section 434.520 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.520 Speculative buildings. 520... for the lighting power provided for the common areas of the building. 520.4Documentation for future...

  7. Environmental effect of structural solutions and building materials to a building

    International Nuclear Information System (INIS)

    Haapio, Appu; Viitaniemi, Pertti

    2008-01-01

    The field of building environmental assessment tools has become a popular research area over the past decade. However, how the service life of a building affects the results of the environmental assessment of a building has not been emphasised previously. The aim of this study is to analyse how different structural solutions and building materials affect the results of the environmental assessment of a whole building over the building's life cycle. Furthermore, how the length of the building's service life affects the results is analysed. The environmental assessments of 78 single-family houses were calculated for this study. The buildings have different wall insulations, claddings, window frames, and roof materials, and the length of the service life varies from 60 years up to 160 years. The current situation and the future of the environmental assessment of buildings are discussed. In addition, topics for further research are suggested; for example, how workmanship affects the service life and the environmental impact of a building should be studied

  8. INDUCON building concept; INDUCON-rakennuskonsepti

    Energy Technology Data Exchange (ETDEWEB)

    Sarja, A.; Laine, J.; Pulakka, S.; Saari, M. [VTT Building and Transport, Espoo (Finland)

    2003-08-01

    of lifetime economy and ecology, and methodology and methods of lifetime optimisation and decision-making). As a case is presented a design, economic and ecological optimisation and multiple attribute decision-making of an experimental building. As a specific issue is resulted the ranking of lifetime economy as a function of energy economy. The ranking starting from the best one was the following: 1. Minimum energy house (annual consumption of space heating energy = 25 kWh/living area m{sup 2}) 2. Low energy house (annual consumption of space heating energy = 75 kWh/living area m{sup 2}) 3. Standard house, Finnish energy standard 2003 (annual consumption of space heating energy = 100 kWh/living area m{sup 2}) 4. Standard house, Finnish energy standard 1985-2002 (annual consumption of space heating energy = 150 kWh/living area m{sup 2}). This result shows, that it is economic, from the viewpoint of lifetime economy in the design period 15 to 50 years to build buildings with much higher energy efficiency than the current standard level. (orig.)

  9. SEISMIC EVALUATION OF EXISTING MID-RISE REINFORCED CONCRETE BUILDINGS ACCORDING TO SPECIFICATION FOR BUILDING STRUCTURES TO BE BUILT IN DISASTER AREAS

    Directory of Open Access Journals (Sweden)

    Mehmet İNEL

    2007-01-01

    Full Text Available Over the past several decades, Turkey has been hit by devastating earthquakes and remarkable number of reinforced concrete buildings has been damaged in the high seismicity regions of our country. The aim of this study is to evaluate the seismic performance of the mid-rise reinforced concrete buildings that are major part of building stock of our earthquake-prone country, according to recent Turkish Earthquake Code. 4- and 7-story buildings were selected to represent mid-rise building stock. After determining the structural parameters, each building was subjected to pushover analysis and the capacity curves were obtained. Earthquake performance of each building was determined in the light of their capacity curves according to the recent Turkish Earthquake Code.

  10. Corrective Action Decision Document, Area 15 Environmental Protection Agency Farm Laboratory Building, Corrective Action Unit No. 95, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-18

    This report is the Corrective Action Decision Document (CADD) for the Nevada Test Site (NTS) Area 15 U.S. Environmental Protection Agency (EPA) Farm, Laboratory Building (Corrective Action Unit [CAU] No. 95), at the Nevada Test Site, Nye County, Nevada. The scope of this CADD is to identify and evaluate potential corrective action alternatives for the decommissioning and decontamination (D and D) of the Laboratory Building, which were selected based on the results of investigative activities. Based on this evaluation, a preferred corrective action alternative is recommended. Studies were conducted at the EPA Farm from 1963 to 1981 to determine the animal intake and retention of radionuclides. The main building, the Laboratory Building, has approximately 370 square meters (4,000 square feet) of operational space. Other CAUS at the EPA Farm facility that will be investigated and/or remediated through other environmental restoration subprojects are not included in this CADD, with the exception of housekeeping sites. Associated structures that do not require classification as CAUS are considered in the evaluation of corrective action alternatives for CAU 95.

  11. Corrective Action Decision Document, Area 15 Environmental Protection Agency Farm Laboratory Building, Corrective Action Unit No. 95, Revision 0

    International Nuclear Information System (INIS)

    1997-01-01

    This report is the Corrective Action Decision Document (CADD) for the Nevada Test Site (NTS) Area 15 U.S. Environmental Protection Agency (EPA) Farm, Laboratory Building (Corrective Action Unit [CAU] No. 95), at the Nevada Test Site, Nye County, Nevada. The scope of this CADD is to identify and evaluate potential corrective action alternatives for the decommissioning and decontamination (D and D) of the Laboratory Building, which were selected based on the results of investigative activities. Based on this evaluation, a preferred corrective action alternative is recommended. Studies were conducted at the EPA Farm from 1963 to 1981 to determine the animal intake and retention of radionuclides. The main building, the Laboratory Building, has approximately 370 square meters (4,000 square feet) of operational space. Other CAUS at the EPA Farm facility that will be investigated and/or remediated through other environmental restoration subprojects are not included in this CADD, with the exception of housekeeping sites. Associated structures that do not require classification as CAUS are considered in the evaluation of corrective action alternatives for CAU 95

  12. Check and evaluation system on heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of china based on multi-index comprehensive evaluation method

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    Heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China is organized and implemented in a large scale by local government in 15 provinces of North China with the unified guidance and control of central government. Firstly, this paper introduced the target of energy-saving reformation of existing residential buildings in North China and the importance of check and evaluation on this target, then pointed out the necessity of building up an evaluation system for energy-saving retrofit. According to the analytical hierarchy process (AHP), three-grade evaluation system was built up for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China. Also, based on multi-index comprehensive evaluation method combined with life cycle assessment (LCA) theory, post-evaluation thought and successful degree evaluation method, a mathematical model was established. Finally, a set of scientific method for evaluating heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China systematically, scientifically, comprehensively and objectively was created.

  13. Learning from tradition. Construction techniques and repair of historical buildings in the area of Brescia: some examples

    Directory of Open Access Journals (Sweden)

    Barbara Scala

    2016-06-01

    The essay focuses on the area of Brescia where, in spite of significant transformations over time of buildings and territory, many examples of traditional architecture still exist. The aim of the paper is also to suggest, by presenting some case studies, a strategy for conservation which proposes a dialogue between traditional methods, technological innovations and economic sustainability of interventions. Keywords: Traditional architecture, Brescia, Sustainability, Construction techniques, Protection

  14. Building founding method

    International Nuclear Information System (INIS)

    Tateno, Seiya; Hirako, Shizuka.

    1996-01-01

    The lower portion of a reactor building is buried at a level of a base rock. In the step of building construction, the base rock around the building is dug of keeping a construction space. The base rock present between the digging line and the building is replaced with an artificial base rock comprising aggregates and cement having a building constraining force substantially equal with that of the lower supporting base rock to obtain constraining force for the side portion of the building. The building itself is made of concrete steels. As the material for replacing the base rock between the digging line and the building, non-reinforced concrete having no steels may provide sufficient function. The burying depth is determined so as to align the surface of the base rock with the level of the base floor of the building. With such procedures, since it is not necessary to increase the area of the lower portion of the building, the amount of the materials for the building can be reduced. In addition, the earthquakes stability can be ensured without changing the shape of the building. (I.N.)

  15. Lessons learned from the 2016 Kumamoto earthquake: Building damages and behavior of seismically isolated buildings

    Science.gov (United States)

    Morita, Keiko; Takayama, Mineo

    2017-10-01

    Powerful earthquakes stuck Kumamoto and Oita Prefectures in Kyushu, Japan. It began with the Magnitude 6.5 foreshock at 21:26 JST 14 April, followed by the Magnitude 7.3 mainshock at 1:25 JST 16 April, 2016. The sequence earthquakes also involved more than 1700 perceptible earthquakes as of 13 June. The entire sequence was named the 2016 Kumamoto earthquake by the Japan Meteorological Agency. Thousands of buildings and many roads were damaged, and landslides occurred. The Japanese building standard law is revised in 1981. Structural damages were concentrated on buildings constructed prior to 1981. The area of Mashiki and Southern Aso were most badly affected, especially wooden houses extremely damaged. In Japan, Prof. Hideyuki Tada (title at the time) undertook research on laminated rubber bearings in 1978, and put it into practical use in 1981. The single family house at Yachiyodai, Chiba Prefecture is completed in 1983, it's the first seismically isolated building which is installed laminated rubber bearings in Japan. Afterward, this system is gradually adopted to mainly office buildings, like a research laboratory, a hospital, a computer center and other offices. In the 1994 Northridge earthquake, the 1995 Kobe earthquake and 2011 Tohoku earthquake, seismically isolated buildings improve these good performances, and recently number of the buildings have increased, mainly high risk area of earthquakes. Many people believed that Kumamoto was a low risk area. But there were 24 seismically isolated buildings in Kumamoto Prefecture at the time. The seismically isolated buildings indicated excellent performances during the earthquakes. They protected people, buildings and other important facilities from damages caused by the earthquake. The purpose of this paper is to discuss lessons learned from the 2016 Kumamoto earthquake and behavior of seismically isolated buildings in the earthquake.

  16. Building 774: open for business

    CERN Multimedia

    CERN Bulletin

    2015-01-01

    In July 2012, the demolition of Building 936 on the Prévessin site marked the start of the Building 774 project. On 23 February, less than three years later, the new 3900 m2 building was handed over to the BE department.   The brand new Building 774. (Credits: Francesco Soppelsa) Located near to the CERN Control Centre, Building 774 contains offices, laboratories and meeting rooms, as well as a huge public area consisting of a 104-seat auditorium, a changing room/shower area in the basement and a pleasant cafeteria open from 8 a.m. to 5 p.m., offering a wide range of refreshments including hot meals at lunchtime. “There were a few twists and turns during the construction of this building, but it all turned out well in the end!" says Michael Poehler, a member of the GS-SE group and the technical coordinator of the project. (Credits: Francesco Soppelsa) The 120 occupants of the building have just moved into their brand new home, bringing all the members of the...

  17. Tech Area II: A history

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, R. [Ktech Corp., Albuquerque, NM (United States)

    1998-07-01

    This report documents the history of the major buildings in Sandia National Laboratories` Technical Area II. It was prepared in support of the Department of Energy`s compliance with Section 106 of the National Historic Preservation Act. Technical Area II was designed and constructed in 1948 specifically for the final assembly of the non-nuclear components of nuclear weapons, and was the primary site conducting such assembly until 1952. Both the architecture and location of the oldest buildings in the area reflect their original purpose. Assembly activities continued in Area II from 1952 to 1957, but the major responsibility for this work shifted to other sites in the Atomic Energy Commission`s integrated contractor complex. Gradually, additional buildings were constructed and the original buildings were modified. After 1960, the Area`s primary purpose was the research and testing of high-explosive components for nuclear weapons. In 1994, Sandia constructed new facilities for work on high-explosive components outside of the original Area II diamond-shaped parcel. Most of the buildings in the area are vacant and Sandia has no plans to use them. They are proposed for decontamination and demolition as funding becomes available.

  18. Fiber optic sensor based on Mach-Zehnder interferometer for securing entrance areas of buildings

    Science.gov (United States)

    Nedoma, Jan; Fajkus, Marcel; Martinek, Radek; Mec, Pavel; Novak, Martin; Bednarek, Lukas; Vasinek, Vladimir

    2017-10-01

    Authors of this article focused on the utilization of fiber optic sensors based on interferometric measurements for securing entrance areas of buildings such as windows and doors. We described the implementation of the fiber-optic interferometer (type Mach-Zehnder) into the window frame or door, sensor sensitivity, analysis of the background noise and methods of signal evaluation. The advantage of presented solution is the use of standard telecommunication fiber standard G.652.D, high sensitivity, immunity of sensor to electromagnetic interference (EMI) and passivity of the sensor regarding power supply. Authors implemented the Graphical User Interface (GUI) which offers the possibility of remote monitoring presented sensing solution.

  19. Sustainable Buildings in Interaction

    DEFF Research Database (Denmark)

    Elle, Morten

    2007-01-01

    The first attempts to build sustainable buildings in Denmark were typically located on the countryside. The basic idea was to create buildings that were independent of the technical infrastructure. District heating has, however, been the dominating solution to heating in buildings in Denmark......, and the focus on sustainable building have gradually turned from special houses on the countryside to normally looking houses in the urban fabric, integrated in the technical infrastructure. Some new built urban areas in Denmark will, however, not have to be supplied with district heating – these developments...... are going to consist of passive houses. The first sustainable buildings were built by their users, and the user – building interaction still play a decisive role for the performance of the present sustainable buildings. The users have to understand how the building functions. Urban design is essential...

  20. Building Deformation Assessment by Means of Persistent Scatterer Interferometry Analysis on a Landslide-Affected Area: The Volterra (Italy Case Study

    Directory of Open Access Journals (Sweden)

    Silvia Bianchini

    2015-04-01

    Full Text Available In recent years, space-borne InSAR (interferometric synthetic aperture radar techniques have shown their capabilities to provide precise measurements of Earth surface displacements for monitoring natural processes. Landslides threaten human lives and structures, especially in urbanized areas, where the density of elements at risk sensitive to ground movements is high. The methodology described in this paper aims at detecting terrain motions and building deformations at the local scale, by means of satellite radar data combined with in situ validation campaigns. The proposed approach consists of deriving maximum settlement directions of the investigated buildings from displacement data revealed by radar measurements and then in the cross-comparison of these values with background geological data, constructive features and on-field evidence. This validation permits better understanding whether or not the detected movements correspond to visible and effective damages to buildings. The method has been applied to the southwestern sector of Volterra (Tuscany region, Italy, which is a landslide-affected and partially urbanized area, through the use of COSMO-SkyMed satellite images as input data. Moreover, we discuss issues and possible misinterpretations when dealing with PSI (Persistent Scatterer Interferometry data referring to single manufactures and the consequent difficulty of attributing the motion rate to ground displacements, rather than to structural failures.

  1. Learning from Abruzzo earthquake buildings behaviour seen from the Building According-to-the-book perspectives

    International Nuclear Information System (INIS)

    Bazurro, P.; Benedettini, F.; Clemente, P.; Salvatori, A.

    2009-01-01

    A brief description, with the related photographs, is reported on the effects of the recent Abruzzo earthquake on buildings, particularly reinforced-concrete and masonry buildings. Following an overview of the technical building codes particularly focused on the area of L'Aquila, mention is made of cultural heritage structures. [it

  2. Comparative Validation of Building Simulation Software

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    The scope of this subtask is to perform a comparative validation of the building simulation software for the buildings with the double skin façade. The outline of the results in the comparative validation identifies the areas where is no correspondence achieved, i.e. calculation of the air flow r...... is that the comparative validation can be regarded as the main argument to continue the validation of the building simulation software for the buildings with the double skin façade with the empirical validation test cases.......The scope of this subtask is to perform a comparative validation of the building simulation software for the buildings with the double skin façade. The outline of the results in the comparative validation identifies the areas where is no correspondence achieved, i.e. calculation of the air flow...

  3. The natural radioactivity of building materials used in the Christchurch urban area

    International Nuclear Information System (INIS)

    Chapman, R.H.

    1984-01-01

    The natural gamma radioactivity of a variety of common building materials in Christchurch, has been measured by gamma spectroscopy. Using conversion factors from the literature, relative dose rate indices for the various building materials were calculated and compared. An increasing order of radioactivity concentration was found from timber to compressed limestone to brick products. These levels are however less than the acceptable limits of radioactivity based on some overseas criteria suggested as building standards

  4. Measurements of the Received Signal Level and Service Coverage Area at the IEEE 802.11 Access Point in the Building

    Science.gov (United States)

    Gunantara, N.; Sudiarta, P. K.; Prasetya, AAN A. I.; Dharma, A.; Gde Antara, I. N.

    2018-04-01

    Access point (AP) is part of a Wireless Local Access Network (WLAN) with its communications using WiFi. AP is used to transmit and receive data to users/clients. The ability of AP to serve users/clients depends on many factors. Moreover, if AP is applied in conditions inside the building. In this study, AP is installed at two points inside the building and then measured in the form of the received signal level (RSL) and service coverage area. One AP measured its performance by 26 measurement points and the other AP measured its performance by 20 measurement points. When AP has measured its performance then another AP position is switched off. Based on the measurement result, the received signal level value is the highest value is about -47 dBm at a distance of 3.2 m, while the lowest is about -79 dBm at a 9.21 m because it is on barrier 2 walls. While based on service coverage area, the area which is far away from the AP then the quality of service becomes bad because the transmitted signal is weakening caused by the distance and the loss of the wall.

  5. The Suitability of Limestone from Pilaspi Formation (Middle-Late Eocene for Building Stone in Koya Area, NE Iraq

    Directory of Open Access Journals (Sweden)

    Hemn M. Omar

    2015-09-01

    Full Text Available Suitability of limestone rocks has a crucial importance when stones are used for constructing modern structure. The purpose of this study is to clarify the links between physical, mechanical properties of limestone rocks, also their quality to use as building materials. A total of six limestone rock samples were collected from three different outcrops locations within Pilaspi Formation in Koya area. Engineering geological and geotechnical properties of the limestone rocks in the study area were determined based on the field studies and laboratory tests. The field studies included observations/ measurements of rock mass characteristics such as color, grain size, orientation, bedding thickness and weathering state of the rock materials also spacing, persistence, roughness and infilling material of the discontinuities. Laboratory tests were carried out for determining water content, water absorption, density, uniaxial compressive strength, slake durability and porosity of the rock materials. The study results go well with the national and international standards (Iraqi Standards, 1989; American Society for Testing and Materials, 2004; International Society for Rock Mechanics, 1981 and have shown that the limestone rocks are acceptable for building stone.

  6. Bore pile foundation tall buildings closed in the heritage building

    Science.gov (United States)

    Triastuti, Nusa Setiani

    2017-11-01

    Bore pile foundation for high building surroundings heritage building should be not damage. Construction proses must good, no necking, no mixed deep water, no sliding soil, nonporous concrete. Objective the execution of bore pile so that heritage buildings and neighboring buildings that are old do not experience cracks, damage and tilting. The survey methodology was observe the process of the implementation of the dominant silt, clay soil, in addition a limited space and to analyze the results of loading tests, investigations of soil and daily reports. Construction process determines the success of the structure bore pile in high building structure bearing, without damaging a heritage building. Attainment the hard soil depth, density concrete, observable clean reinforcement in the implementation. Monitoring the implementation of, among others, the face of the ground water little reduce in the area and outside the footprint of the building, no impact of vibration drilling equipment, watching the mud content on the water coming out at the time of drilling, concrete volume was monitored each 2 m bore depth of pile, The result researched heritage building was not damage. The test results bore pile axial, lateral analyzed the results have the appropriate force design required.

  7. Metrics for building performance assurance

    Energy Technology Data Exchange (ETDEWEB)

    Koles, G.; Hitchcock, R.; Sherman, M.

    1996-07-01

    This report documents part of the work performed in phase I of a Laboratory Directors Research and Development (LDRD) funded project entitled Building Performance Assurances (BPA). The focus of the BPA effort is to transform the way buildings are built and operated in order to improve building performance by facilitating or providing tools, infrastructure, and information. The efforts described herein focus on the development of metrics with which to evaluate building performance and for which information and optimization tools need to be developed. The classes of building performance metrics reviewed are (1) Building Services (2) First Costs, (3) Operating Costs, (4) Maintenance Costs, and (5) Energy and Environmental Factors. The first category defines the direct benefits associated with buildings; the next three are different kinds of costs associated with providing those benefits; the last category includes concerns that are broader than direct costs and benefits to the building owner and building occupants. The level of detail of the various issues reflect the current state of knowledge in those scientific areas and the ability of the to determine that state of knowledge, rather than directly reflecting the importance of these issues; it intentionally does not specifically focus on energy issues. The report describes work in progress and is intended as a resource and can be used to indicate the areas needing more investigation. Other reports on BPA activities are also available.

  8. DESIGN PROBLEMS OF THE BUILDINGS FOUNDATIONS AND STRUCTURES CONSTRUCTED IN DENSE URBAN AREAS

    OpenAIRE

    O. Yu. Prokopov; M. V. Prokopova

    2007-01-01

    The urgency of methodical provision of planning of foundations for buildings erected next to existing ones is сonsidered. It is based on studying the causes of extension of deformations of structures in conditions of dense city building system. Some recommendations providing safety of buildings are given.

  9. Confidence-building and Canadian leadership

    International Nuclear Information System (INIS)

    Cleminson, F.R.

    1998-01-01

    Confidence-building has come into its own as a 'tool of choice' in facilitating the non-proliferation, arms control and disarmament (NACD) agenda, whether regional or global. From the Middle East Peace Process (MEPP) to the ASEAN Intersessional Group on Confidence-Building (ARF ISG on CBMS), confidence-building has assumed a central profile in regional terms. In the Four Power Talks begun in Geneva on December 9, 1997, the United States identified confidence-building as one of two subject areas for initial discussion as part of a structured peace process between North and South Korea. Thus, with CBMs assuming such a high profile internationally, it seems prudent for Canadians to pause and take stock of the significant role which Canada has already played in the conceptual development of the process over the last two decades. Since the Helsinki accords of 1975, Canada has developed a significant expertise in this area through an unbroken series of original, basic research projects. These have contributed to defining the process internationally from concept to implementation. Today, these studies represent a solid and unique Departmental investment in basic research from which to draw in meeting Canada's current commitments to multilateral initiatives in the area of confidence-building and to provide a 'step up' in terms of future-oriented leadership. (author)

  10. DESIGN PROBLEMS OF THE BUILDINGS FOUNDATIONS AND STRUCTURES CONSTRUCTED IN DENSE URBAN AREAS

    Directory of Open Access Journals (Sweden)

    O. Yu. Prokopov

    2007-10-01

    Full Text Available The urgency of methodical provision of planning of foundations for buildings erected next to existing ones is сonsidered. It is based on studying the causes of extension of deformations of structures in conditions of dense city building system. Some recommendations providing safety of buildings are given.

  11. Nuclear reactor building

    International Nuclear Information System (INIS)

    Oshima, Nobuaki.

    1991-01-01

    The secondary container in a nuclear reactor building is made of a transparent structure having a shielding performance such as lead glass, by which the inside of the secondary container can be seen without undergoing radiation exposure. In addition, an operator transportation facility capable of carrying about 5 to 10 operators at one time is disposed, and the side of the facility on the secondary container is constituted with a transparent material such as glass, to provide a structure capable of observing the inside of the secondary container. The ventilation and air conditioning in the operator's transportation facility is in communication with the atmosphere of a not-controlled area. Accordingly, operators at the outside of the reactor building can reach the operator's transportation facility without taking and procedures for entering the controlled area and without undergoing radiation exposure. The inside of the secondary container in the reactor building can be seen from various directions through the transparent structure having the shielding performance. (N.H.)

  12. Building energy efficiency in rural China

    International Nuclear Information System (INIS)

    Evans, Meredydd; Yu, Sha; Song, Bo; Deng, Qinqin; Liu, Jing; Delgado, Alison

    2014-01-01

    Rural buildings in China now account for more than half of China's total building energy use. Forty percent of the floorspace in China is in rural villages and towns. Most of these buildings are very energy inefficient, and may struggle to provide for basic needs. They are cold in the winter, and often experience indoor air pollution from fuel use. The Chinese government plans to adopt a voluntary building energy code, or design standard, for rural homes. The goal is to build on China's success with codes in urban areas to improve efficiency and comfort in rural homes. The Chinese government recognizes rural buildings represent a major opportunity for improving national building energy efficiency. The challenges of rural China are also greater than those of urban areas in many ways because of the limited local capacity and low income levels. The Chinese government wants to expand on new programs to subsidize energy efficiency improvements in rural homes to build capacity for larger-scale improvement. This article summarizes the trends and status of rural building energy use in China. It then provides an overview of the new rural building design standard, and describes options and issues to move forward with implementation. - Highlights: • Building energy use is larger in rural China than in cities. • Rural buildings are very energy intensive, and energy use is growing with incomes. • A new design standard aims to help rural communities build more efficiently. • Important challenges remain with implementation

  13. Capacity building for the effective adoption of renewable energy technologies in rural areas. Experience of India NGOs

    Energy Technology Data Exchange (ETDEWEB)

    Myles, R. [Integrated Sustainable Energy and Ecological Development Association (INSEDA), New Delhi (India)

    2002-07-01

    The experience of NGO network in the promotions of biogas and other low cost RET gadgets, devices, equipments and machines in the rural areas of India, for over two decades, have shown that there are serveral problems yet challenging opportunities in the promotion and implementation of renewable energy technologies in villages. First of all, the field and extension organizations should recognise that these technologies are new and aliens to the rural people, therefore like any other technologies, developed outside the rural environment, RETs are first view with skepticism by the rural community. Even if 100 units of a RE technology are successfully demonstrated, failure of even one could create negative impact within a radius of 30-50 KMs, and its shortcomings are spread like a wild fire. The appropriate technology demonstration backed by systematic capacity building of different stakeholders/actors/players (i.e. Energy Producers, Energy Service Providers and the Energy End Users) is a must for the acceptance and large-scale adoption of RETs in rural areas of the developing countries. The programme funds for the promotion and implementation of RETs should have good percentage earmarked for the capacity building as well as supporting infrastructure for awareness, motivation, promotional and post installation services activities by local field level organizations and NGOs on a long term basis. (orig.)

  14. A New Look at Building Facades as Infrastructure

    Directory of Open Access Journals (Sweden)

    Doris Sung

    2016-03-01

    Full Text Available Like the hard surfaces of streets and sidewalks in an urban environment, the vertical and horizontal surface area on the outside of urban buildings contributes to the constant heating of large cities around the world. However, little is done to design this surface to benefit the public sphere. Instead, the facade of a building performs either as a component that focuses only on the quality of comfort for interior occupants, while ignoring effects on the exterior of the building, or as an identifiable aesthetic for the building's owners. This essay proposes the rethinking of the building facade as a steward of outdoor pedestrian welfare, and the conception of public health as an added function of the building envelope−a concept that may fall into the jurisdiction of public works. If the huge total surface area of a city's buildings is thought of as part of the city's infrastructure, then its public contribution may not only make outdoor areas comfortable, clean, and enjoyable, but also help to alleviate the bigger problem of rising temperatures in cities.

  15. The Important Bird Areas Program in the United States: building a network of sites for conservation, state by state

    Science.gov (United States)

    Jeffrey V. Wells; Daniel K. Niven; John Cecil

    2005-01-01

    The Important Bird Area (IBA) program is an international effort to identify, conserve, and monitor a network of sites that provide essential habitat for bird populations. BirdLife International began the IBA program in Europe in 1985. Since that time, BirdLife partners in more than 100 countries have joined together to build the global IBA network. Audubon (BirdLife...

  16. Capacity Building in Land Management

    DEFF Research Database (Denmark)

    Enemark, Stig; Ahene, Rexford

    2003-01-01

    There is a significant need for capacity building in the interdisciplinary area of land management especially in developing countries and countries in transition, to deal with the complex issues of building efficient land information systems and sustainable institutional infrastructures. Capacity...... building in land management is not only a question of establishing a sufficient technological level or sufficient economic resources. It is mainly a question of understanding the interdisciplinary and cross-sectoral nature of land administration systems, and understanding the need for human resource...... and professionals for implementing the new land policy. The curriculum combines the diploma and the bachelor level and it combines the key areas of land surveying, land management and physical planning....

  17. Simulation of thermal indoor climate in buildings by using human Projected Area Factors

    DEFF Research Database (Denmark)

    Christensen, Jørgen Erik

    2009-01-01

    Nowadays many new and old buildings in Denmark have large glass surfaces. This is a consequence of the technical development of windows with low U-values that has made it possible to build houses with windows from floor to ceiling in northern climates. On the other hand if one is sitting close to...... for dynamic building thermal analysis. The method is demonstrated in a newer apartment with windows from floor to ceiling and shows how impotent it is to include the radiant effect from the glass sur-faces and how it influences the indoor thermal climate significantly.......Nowadays many new and old buildings in Denmark have large glass surfaces. This is a consequence of the technical development of windows with low U-values that has made it possible to build houses with windows from floor to ceiling in northern climates. On the other hand if one is sitting close...

  18. Indoor environmental and air quality characteristics, building-related health symptoms, and worker productivity in a federal government building complex.

    Science.gov (United States)

    Lukcso, David; Guidotti, Tee Lamont; Franklin, Donald E; Burt, Allan

    2016-01-01

    Building Health Sciences, Inc. (BHS), investigated environmental conditions by many modalities in 71 discreet areas of 12 buildings in a government building complex that had experienced persistent occupant complaints despite correction of deficiencies following a prior survey. An online health survey was completed by 7,637 building occupants (49% response rate), a subset of whom voluntarily wore personal sampling apparatus and underwent medical evaluation. Building environmental measures were within current standards and guidelines, with few outliers. Four environmental factors were consistently associated with group-level building-related health complaints: physical comfort/discomfort, odor, job stress, and glare. Several other factors were frequently commented on by participants, including cleanliness, renovation and construction activities, and noise. Low relative humidity was significantly associated with lower respiratory and "sick building syndrome"-type symptoms. No other environmental conditions (including formaldehyde, PM10 [particulate matter with an aerodynamic diameter work but at reduced capacity), and increase in reported symptom-days, including symptoms not related to respiratory disease. We found that in buildings without unusual hazards and with environmental and air quality indicators within the range of acceptable indoor air quality standards, there is an identifiable population of occupants with a high prevalence of asthma and allergic disease who disproportionately report discomfort and lost productivity due to symptoms and that in "normal" buildings these outcome indicators are more closely associated with host factors than with environmental conditions. We concluded from the experience of this study that building-related health complaints should be investigated at the work-area level and not at a building-wide level. An occupant-centric medical evaluation should guide environmental investigations, especially when screening results of building

  19. Confidence-building and Canadian leadership

    Energy Technology Data Exchange (ETDEWEB)

    Cleminson, F.R. [Dept. of Foreign Affairs and International Trade, Verification, Non-Proliferation, Arms Control and Disarmament Div (IDA), Ottawa, Ontario (Canada)

    1998-07-01

    Confidence-building has come into its own as a 'tool of choice' in facilitating the non-proliferation, arms control and disarmament (NACD) agenda, whether regional or global. From the Middle East Peace Process (MEPP) to the ASEAN Intersessional Group on Confidence-Building (ARF ISG on CBMS), confidence-building has assumed a central profile in regional terms. In the Four Power Talks begun in Geneva on December 9, 1997, the United States identified confidence-building as one of two subject areas for initial discussion as part of a structured peace process between North and South Korea. Thus, with CBMs assuming such a high profile internationally, it seems prudent for Canadians to pause and take stock of the significant role which Canada has already played in the conceptual development of the process over the last two decades. Since the Helsinki accords of 1975, Canada has developed a significant expertise in this area through an unbroken series of original, basic research projects. These have contributed to defining the process internationally from concept to implementation. Today, these studies represent a solid and unique Departmental investment in basic research from which to draw in meeting Canada's current commitments to multilateral initiatives in the area of confidence-building and to provide a 'step up' in terms of future-oriented leadership. (author)

  20. Earthquake-resistant performance investigation for rural buildings in Zhongxiang area, China

    Directory of Open Access Journals (Sweden)

    Lei Jingya

    2013-02-01

    Full Text Available We carried out a census of the rural residential buildings of Zhongxiang area’s 17 towns. Next, we conducted a sample survey in four townships: Huji, Shipai, Zhangji, and Jiuli. According to the census and sample survey data of the rural residence buildings, we evaluated the quality and earthquake-resistant performance of the rural buildings for the various local rural residential structural types. The results showed that there are four main factors affecting the seismic performance of the local rural residences: (1 Foundations are not made appropriately (such as by compaction or some other fill but are built directly in the farming soil. (2 Seismic measures are not completely implemented. Structure construction measures are not in place at the junction of the vertical and horizontal wall. The vertical wall joints are not the result of the same masonry techniques as the horizontal joints. There are no lintels above the door and window openings, or if there are any, the length of the lintels is less than 240 mm. (3 The brick masonry wall has low strength. The greatest housing wall mortar strength is between M0. 4–1.5, much lower than the strength of the brick. (4 The building material and construction quality are poor. The quality of the mortar masonry wall is poor. The cracks between the bricks are uneven, even in the seams.

  1. Object Based Building Extraction and Building Period Estimation from Unmanned Aerial Vehicle Data

    Science.gov (United States)

    Comert, Resul; Kaplan, Onur

    2018-04-01

    The aim of this study is to examine whether it is possible to estimate the building periods with respect to the building heights in the urban scale seismic performance assessment studies by using the building height retrieved from the unmanned aerial vehicle (UAV) data. For this purpose, a small area, which includes eight residential reinforced concrete buildings, was selected in Eskisehir (Turkey) city center. In this paper, the possibilities of obtaining the building heights that are used in the estimation of building periods from UAV based data, have been investigated. The investigations were carried out in 3 stages; (i) Building boundary extraction with Object Based Image Analysis (OBIA), (ii) height calculation for buildings of interest from nDSM and accuracy assessment with the terrestrial survey. (iii) Estimation of building period using height information. The average difference between the periods estimated according to the heights obtained from field measurements and from the UAV data is 2.86 % and the maximum difference is 13.2 %. Results of this study have shown that the building heights retrieved from the UAV data can be used in the building period estimation in the urban scale vulnerability assessments.

  2. Air conditioning device for reactor buildings

    International Nuclear Information System (INIS)

    Kikuchi, Shiro.

    1982-01-01

    Purpose: To decrease the opening areas of pipe lines for an air conditioning device at the portions passing through the shielding walls of a reactor building for a FBR type reactor, as well as reduce the size of the building. Constitution: Airs in the building for containing reactor are liquefied in an air liquefying mechanism. The liquefied airs are sent by way of pipe lines to each of evaporators, wherein each of the chambers are cooled because of latent heat of evaporation and evaporated airs are released to each of the chambers. The airs released to each of the chambers are collected into an exhaust chamber and sent by way of a duct to the air liquefying mechanism and liquefied again. Since the volume of the liquefied airs may be smaller than the amount conventionally required for usual cooled airs, the pipe lines passing through the shielding walls of the building can be of smaller diameter. This can decrease the opening areas of the pipe lines at the portions passing through the walls of the shieldings and, since the opening areas are smaller, the structure of the radiation shieldings can be simplified in these portions. Further, since the space of the pipe lines in the building is reduced extremely, the size of the building can be reduced. (Moriyama, K.)

  3. Analysis of Embodied Environmental Impacts of Korean Apartment Buildings Considering Major Building Materials

    Directory of Open Access Journals (Sweden)

    Seungjun Roh

    2018-05-01

    Full Text Available Because the reduction in environmental impacts (EIs of buildings using life-cycle assessment (LCA has been emphasized as a practical strategy for the sustainable development of the construction industry, studies are required to analyze not only the operational environmental impacts (OEIs of buildings, but also the embodied environmental impacts (EEIs of building materials. This study aims to analyze the EEIs of Korean apartment buildings on the basis of major building materials as part of research with the goal of reducing the EIs of buildings. For this purpose, six types of building materials (ready-mixed concrete, reinforcement steel, concrete bricks, glass, insulation, and gypsum for apartment buildings were selected as major building materials, and their inputs per unit area according to the structure types and plans of apartment buildings were derived by analyzing the design and bills of materials of 443 apartment buildings constructed in South Korea. In addition, a life-cycle scenario including the production, construction, maintenance, and end-of-life stage was constructed for each major building material. The EEIs of the apartment buildings were quantitatively assessed by applying the life-cycle inventory database (LCI DB and the Korean life-cycle impact assessment (LCIA method based on damage-oriented modeling (KOLID, and the results were analyzed.

  4. Building regulations, planning of building constructions and housing development areas taking into account the utilization of solar energy

    Energy Technology Data Exchange (ETDEWEB)

    Bierhals, R; Schaefer, G; Weigert, D

    1977-01-01

    Complete systems for utilizing solar energy both for hot water preparation and for space heating are available in the FRG today. However, solar technology is unlikely to prevail without governmental support since the plants are still too expensive although there is a principal positive attitude towards solar energy. More knowledge of the process of solar energy utilization is necessary both in the field of building laws, and for building enterprises, architects and planners, if this new form of energy is to succeed.

  5. Impacts of traffic composition and street-canyon geometry on on-road air quality in a high-rise building area

    Science.gov (United States)

    Kwak, Kyung-Hwan; Kim, Kyung Hwan; Lee, Seung-Bok; Woo, Sung Ho; Bae, Gwi-Nam; Sunwoo, Young; Baik, Jong-Jin

    2016-04-01

    Mobile measurements using a mobile laboratory and numerical simulations using a computational fluid dynamics (CFD) model were conducted over different time periods of multiple days in a high-rise building area, Seoul, Republic of Korea. Mobile measurement can provide actual on-road emission levels of air pollutants from vehicles as well as validation dataset of a CFD model. On the other hand, CFD modeling is required for the process analysis of mobile measurement data and the quantitative estimation of determining factors in complex phenomena. The target area is characterized as a busy street canyon elongated along a major road with hourly traffic volumes of approximately 4000 vehicles during working hours on weekdays. Nitrogen oxides (NOx), black carbon (BC), particle-bound polycyclic aromatic hydrocarbons (pPAH), and particle number (PN) concentrations were measured during 39 round trips of mobile laboratory. The associations of the measured NOx, BC, pPAH, and PN concentrations with the traffic volumes of individual compositions are analyzed by calculating the correlation coefficients (R2) based on linear regressions. It is found that SUV, truck, van, and bus are heavy emitters responsible for the on-road air pollution in the street canyon. Among the measured pollutants, the largest R2 is shown for pPAH. The measured NOx, BC, pPAH, and PN concentrations are unevenly distributed in the street canyon. The measured concentrations around an intersection are higher than those in between intersections, particularly for NOx and pPAH. The CFD modeling for different dispersion scenarios reveals that the intersection has counterbalancing roles in determining the on-road concentrations. The emission process acts to increase the on-road concentrations due to accelerating and idling vehicles, whereas the dispersion process acts to decrease the on-road concentrations due to lateral ventilations along the crossing street. It is needed to control the number of heavy emitters and

  6. Analysis of Building Envelope Construction in 2003 CBECS

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, David W.; Halverson, Mark A.; Jiang, Wei

    2007-06-01

    The purpose of this analysis is to determine "typical" building envelope characteristics for buildings built after 1980. We address three envelope components in this paper - roofs, walls, and window area. These typical building envelope characteristics were used in the development of DOE’s Reference Buildings .

  7. The sick-building syndrome; Das Sick-Building-Syndrom

    Energy Technology Data Exchange (ETDEWEB)

    Henne, A.; Neumann, H.F.; Winneke, G.

    1992-12-31

    The sick-building syndrome is characterized by the presence of general, non-specific symptoms (e.g., headache, tiredness, respiratory problems, eye trouble, vertigo, nausea, unspecific hypersensitivity) in association with a particular indoor ambience. It is clearly distinguishable from `building-related illness`, referring to a well-defined clinical syndrome due to staying in a building and for which a cause can, in general, be established. Disorders in the case of the sick-building syndrome are manifold and confirmed objectifiable results are hardly available so far. Yet there are some organ-related methods for the confirmation of findings concerning, for instance, the eyes, the skin and the area of the nose. The causes of the incidence of sick-building syndrome are more or less unclear. It is a multifactorial phenomenon involving physical, biological, chemical, individual-specific and psychological factors. Buildings where sick-building syndrome occurs typically exhibit certain properties. The European Community has already made proposals for the investigation of incriminated buildings. A systematic survey by questionnaire together with individual interviews plays an import part towards clarifying the syndrome. (orig./UWA) [Deutsch] Das Sick-Building-Syndrom beschreibt das Vorhandensein von allgemeinen, nicht spezifischen Symptomen (z.B. Kopfschmerzen, Muedigkeit, Atembeschwerden, Augenreizungen, Schwindelgefuehl, Uebelkeit, unspezifische Ueberempfindlichkeit), assoziiert mit einer besonderen Innenraumumgebung. Deutlich hiervon abzugrenzen ist die ``Building related illness``, bei der ein klinisch definiertes Krankheitsbild vorliegt, das durch den Aufenthalt im Gebaeude verursacht wird und fuer das im allgemeinen eine Ursache ermittelt werden kann. Das Beschwerdebild beim Sick-Building-Syndrom ist vielfaeltig, und gesicherte, objektivierbare Befunde liegen hierzu bisher kaum vor. Dennoch gibt es einige organbezogenen Methoden zur Befundabsicherung, z.B. fuer das

  8. Waste processing building with incineration technology

    Science.gov (United States)

    Wasilah, Wasilah; Zaldi Suradin, Muh.

    2017-12-01

    In Indonesia, waste problem is one of major problem of the society in the city as part of their life dynamics. Based on Regional Medium Term Development Plan of South Sulawesi Province in 2013-2018, total volume and waste production from Makassar City, Maros, Gowa, and Takalar Regency estimates the garbage dump level 9,076.949 m3/person/day. Additionally, aim of this design is to present a recommendation on waste processing facility design that would accommodate waste processing process activity by incineration technology and supported by supporting activity such as place of education and research on waste, and the administration activity on waste processing facility. Implementation of incineration technology would reduce waste volume up to 90% followed by relative negative impact possibility. The result planning is in form of landscape layout that inspired from the observation analysis of satellite image line pattern of planning site and then created as a building site pattern. Consideration of building orientation conducted by wind analysis process and sun path by auto desk project Vasari software. The footprint designed by separate circulation system between waste management facility interest and the social visiting activity in order to minimize the croos and thus bring convenient to the building user. Building mass designed by inseparable connection series system, from the main building that located in the Northward, then connected to a centre visitor area lengthways, and walked to the waste processing area into the residue area in the Southward area.

  9. TA-03-0035 Press Building – D&D

    Energy Technology Data Exchange (ETDEWEB)

    Hasenack, Marvin Leroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-02

    The Press Building was constructed in 1954 with 15,073 ft2 of floor space. It was built to house a 5000 ton double action Lake Erie hydraulic press and a uranium casting area. Missions included uranium activities associated with the Nuclear Weapons and Rover Rocket programs. At the end of the Rover program, the building continued to support various uranium materials science projects until the building was placed into a cold and dark status in 2013 and then was demolished in 2017. The building interior, the press, and associated systems were radiological contaminated and disposed of as low level waste. The demolition of this building opened up valuable real estate in the TA-3 area for the future construction of an ~11,000 Sq. Ft. Biosafety Level 2 laboratory and office building. This building will support the ongoing Bioscience Division mission at the laboratory.

  10. Commercial Building Partnerships Replication and Diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Antonopoulos, Chrissi A.; Dillon, Heather E.; Baechler, Michael C.

    2013-09-16

    This study presents findings from survey and interview data investigating replication efforts of Commercial Building Partnership (CBP) partners that worked directly with the Pacific Northwest National Laboratory (PNNL). PNNL partnered directly with 12 organizations on new and retrofit construction projects, which represented approximately 28 percent of the entire U.S. Department of Energy (DOE) CBP program. Through a feedback survey mechanism, along with personal interviews, PNNL gathered quantitative and qualitative data relating to replication efforts by each organization. These data were analyzed to provide insight into two primary research areas: 1) CBP partners’ replication efforts of technologies and approaches used in the CBP project to the rest of the organization’s building portfolio (including replication verification), and, 2) the market potential for technology diffusion into the total U.S. commercial building stock, as a direct result of the CBP program. The first area of this research focused specifically on replication efforts underway or planned by each CBP program participant. Factors that impact replication include motivation, organizational structure and objectives firms have for implementation of energy efficient technologies. Comparing these factors between different CBP partners revealed patterns in motivation for constructing energy efficient buildings, along with better insight into market trends for green building practices. The second area of this research develops a diffusion of innovations model to analyze potential broad market impacts of the CBP program on the commercial building industry in the United States.

  11. Photovoltaics for Buildings Cutting-Edge PV

    International Nuclear Information System (INIS)

    Hayter, S. J.; Martin, R. L.

    1998-01-01

    Photovoltaic (PV) technology development for building-integrated applications (commonly called PV for Buildings) is one of the fastest growing areas in the PV industry. Buildings represent a huge potential market for photovoltaics because they consume approximately two-thirds of the electricity consumed in the US. The PV and buildings industries are beginning to work together to address issues including building codes and standards, integration, after-market servicing, education, and building energy efficiency. One of the most notable programs to encourage development of new PV-for-buildings products is the PV:BONUS program, supported by the US Department of Energy. Demand for these products from building designers has escalated since the program was initiated in 1993. This paper presents a range of PV-for-buildings issues and products that are currently influencing today's PV and buildings markets

  12. Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making.

    Science.gov (United States)

    Maddalena, R; Mendell, M J; Eliseeva, K; Chan, W R; Sullivan, D P; Russell, M; Satish, U; Fisk, W J

    2015-08-01

    Ventilation rates (VRs) in buildings must adequately control indoor levels of pollutants; however, VRs are constrained by the energy costs. Experiments in a simulated office assessed the effects of VR per occupant on perceived air quality (PAQ), Sick Building Syndrome (SBS) symptoms, and decision-making performance. A parallel set of experiments assessed the effects of VR per unit floor area on the same outcomes. Sixteen blinded healthy young adult subjects participated in each study. Each exposure lasted four hours and each subject experienced two conditions in a within-subject study design. The order of presentation of test conditions, day of testing, and gender were balanced. Temperature, relative humidity, VRs, and concentrations of pollutants were monitored. Online surveys assessed PAQ and SBS symptoms and a validated computer-based tool measured decision-making performance. Neither changing the VR per person nor changing the VR per floor area, had consistent statistically significant effects on PAQ or SBS symptoms. However, reductions in either occupant-based VR or floor-area-based VR had a significant and independent negative impact on most decision-making measures. These results indicate that the changes in VR employed in the study influence performance of healthy young adults even when PAQ and SBS symptoms are unaffected. The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Diffusion in building wakes

    International Nuclear Information System (INIS)

    Ramsdell, J.V.

    1988-03-01

    Straight-line Gaussian models adequately describe atmospheric diffusion for many applications. They have been modified for use in estimating diffusion in building wakes by adding terms that include projected building area and by redefining the diffusion coefficients so that the coefficients have minimum values that are related to building dimensions. In a recent study, Ramsdell reviewed the building-wake dispersion models used by the Nuclear Regulatory Commission (NRC) in its control room habitability assessments. The review included comparison of model estimates of centerline concentrations with concentrations observed in experiments at seven nuclear reactors. In general, the models are conservative in that they tend to predict concentrations that are greater than those actually observed. However, the models show little skill in accounting for variations in the observed concentrations. Subsequently, the experimental data and multiples linear regression techniques have been used to develop a new building wake diffusion model. This paper describes the new building wake model and compares it with other models. 8 refs., 2 figs

  14. Geophysics: Building E5476 decommissiong, Aberdeen Proving Ground

    International Nuclear Information System (INIS)

    Miller, S.F.; Thompson, M.D.; McGinnis, M.G.; McGinnis, L.D.

    1992-11-01

    Building E5476 was one of ten potentially contaminated sites in the Canal Creek and Westwood areas of the Edgewood section of Aberdeen Proving Ground examined by a geophysical team from Argonne National Laboratory in April and May of 1992. Noninvasive geophysical surveys, including magnetics, electrical resistivity, and ground-penetrating radar, were conducted around the perimeter of the building to guide a sampling program prior to decommissioning and dismantling. The large number of magnetic sources surrounding the building are believed to be contained in construction fill. The smaller anomalies, for the most part, were not imaged with ground radar or by electrical profiling. Large magnetic anomalies near the southwest comer of the building are due to aboveground standpipes and steel-reinforced concrete. Two high-resistivity areas, one projecting northeast from the building and another south of the original structure, may indicate the presence of organic pore fluids in the subsurface. A conductive lineament protruding from the south wall that is enclosed by the southem, high-resistivity feature is not associated with an equivalent magnetic anomaly. Magnetic and electrical anomalies south of the old landfill boundary are probably not associated with the building. The boundary is marked by a band of magnetic anomalies and a conductive zone trending northwest to southeast. The cause of high resistivities in a semicircular area in the southwest comer, within the landfill area, is unexplained

  15. Valorisation of vernacular farm buildings for the sustainable development of rural tourism in mountain areas of the Adriatic-Ionian macro-region

    Directory of Open Access Journals (Sweden)

    Dina Statuto

    2017-08-01

    Full Text Available Rural buildings play a central role on the environmental characteristics of the extra-urban land. They accompanied in the centuries the development of agricultural activities by humans, who was so able to breed cattle, to grow and yield crops, and to store, transform and process agricultural products in a functional and efficient way, working into intensive conditions, so being unaffected by the external climate. On the other hand, constructions built by the farmer-man marked the territory, influencing and steering the spontaneous development of nature, while leading to production that enabled humanity to get food. Vernacular farm buildings, often used as seasonal settlements, are in some cases organised in areas of mountain pasture for summer cattle grazing. Even if in most case they were abandoned during recent years - since people living there moved to more comfortable residences within urban settlements - their contemporary potential for preserving traditional cattle-raising procedures and dairy products, rich cultural-historical heritage and perspectives of organised tourism activities, appears a very intriguing task to be approached. Rural tourism - including agro-, eco- and cultural tourism - offers indeed new opportunities for enjoying the extra-urban land in close contact with naturally untouched landscapes. It enables to appreciate some traditional aspects that the new industrialised modern society may have forgotten. The opportunities offered by rural tourism could help in the development of environmentally friendly tourism, which is growing three times faster than those choosing mainstream trips. With the aim to valorise the vernacular rural buildings in some mountain areas of the Adriatic-Ionian macro-region, in the present paper a first approach was proposed, through the implementation of a geographical information system aimed to survey the current situation into two different mountain areas within this macro-region, located in

  16. Heat Mismatch of future Net Zero Energy Buildings within district heating areas in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    The long-term goal for Denmark is to develop an energy system solely based on renewable energy sources (RES) in 2050. To reach this goal energy savings in buildings are essential. Therefore, a focus on energy efficient measures in buildings and net zero energy buildings (NZEBs) have increased...... systems enables them to send or receive energy from these systems. This is beneficial for NZEBs because even though they have an annual net exchange of zero, there is a temporal mismatch in regard to the energy consumption of buildings and the production from the renewable energy units added to them...

  17. Potential heat savings during ongoing renovation of buildings until 2050

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper; Aggerholm, Søren

    information about insulation level, building component areas, i.e. roofs, external walls, floors and windows/doors, per unit area (gross heated floor area). The report is made for the Danish Energy Agency and targeted the Danish building industry, the agency itself and political decision makers in preparation...

  18. Environmental indicators for buildings

    DEFF Research Database (Denmark)

    Dammann, S.

    Whenever we shop, the products we consider buying are labelled with the economical price we have to pay if we want to purchase them - an important parameter in our decisions as purchasers. The increrasing awareness for environmental limits and backlashes of human activities also in the building...... sector have fostered the wish to define 'the ecological price' of a building as a help for environmental conscious decision-making. In a social constructivist approach this Ph.D. thesis looks across and beyond the manifold existing approaches for environmental indicators for buildings. It acknowledges...... in the Netherlands. It identifies lines of conflict and areas of consent betweeen the relevant actors and elaborates scenarios for a possible closure of ongoing debate about environmental indicators for buildings....

  19. Collecting memories of the city through the conservation of heritage building

    Science.gov (United States)

    Nurliani Lukito, Yulia; Nurul Rizky, Amalia

    2018-03-01

    Heritage building has a role for the city and the society that is associated with emotional, cultural, and use values. Those values are parts of collective memory and create the identity of the city. Some heritage buildings are vulnerable to modernization and even when the government conserves those buildings, some important values of the buildings are lost. This paper discusses a colonial building in Jakarta that has been converted into different functions. As a case study is Cut Meutia Mosque in Menteng, designed by a Dutch architect PAJ Moojen during the Dutch late colonial era. The building was initiated in 1922 as N.V. Bouwploeg, an architectural firm that developed the nearby residential area of New Gondangdia. This area was developed according to modern Garden City principles and the Bouwploeg was known as the gate to Menteng area and the architecture of the building was considered very modern and unique at that time – illustrating the importance of the building for the city. After Indonesia’s independence, the government converted the building into different functions such as an office and a mosque. Although the function of the building has changed, the building is still related to triggering a collective memory of the new area that should not be ignored in the effort of conserving the building. Through historical and field research, the paper aims to discuss some changes and lost values of the building as the result of conserving the colonial heritage, especially about collective memory. Hopefully, learning from the conservation of building heritage and city collective memory may support the idea of livable memory of heritage building and even a

  20. Radon risk in residential buildings

    International Nuclear Information System (INIS)

    Niewiadomski, T.

    1996-01-01

    The author discusses the risk related to the inhalation of radon decay products. This products are the cause of almost the half of the doses absorbed by the people. The concentration of radon in buildings is much higher than in the open areas and its country average in Poland is 50 Bq/m 3 . It is difficult to predict the concentration of radon in the building without measurement. Author concludes that there are technical means to decrease radon concentration in buildings

  1. Building partnership capacity for the collaborative management of marine protected areas in the UK: a preliminary analysis.

    Science.gov (United States)

    Jones, Peter J S; Burgess, Jacquelin

    2005-11-01

    This paper reports the findings of a preliminary analysis of 15 case studies of inshore marine protected areas in the UK. It draws on the common-pool resource (CPR) literature and is premised on the thesis that building partnership capacity amongst relevant authorities and resource users provides a critical basis for overcoming collective action problems (CAPs), through the development of incentive structures and social capital, in order to achieve strategic objectives. Particular attention is paid to the influence of statutory marine biodiversity conservation obligations to the European Commission for marine special areas of conservation (MSACs), as these are an important external contextual factor. The risks of imposition and parochialism are outlined and the challenges of taking a balanced approach are discussed. The challenges posed by the attributes of the marine environment are considered, as are those posed by the policy framework for MSACs. The findings are discussed in relation to three questions: (i) which partnership models appear to have the potential to overcome the CAPs posed by inshore MSACs? (ii) what CAPs had to be addressed during the early phase of development of the MSAC co-management regimes? (iii) what are the likely future CAPs for the collaborative management of MSACs that each partnership will need to address? These preliminary findings will form the basis for future studies to analyse the outcomes of these 15 initiatives, in order to assess the strengths, in various contexts, of different approaches for building resilient and balanced, thereby effective, institutions for the co-management of MSACs in the UK.

  2. Area 3 Support Buildings (A3SB) H5-0992, H5-0996 PRL 218 Confirmatory Sampling Report

    Science.gov (United States)

    Mrdjenovich, Timothy

    2015-01-01

    The Area 3 Support Buildings site (A3SB) consists of two separate areas located on the north side of Beach Road in the northern portion of Kennedy Space Center, Florida (KSC), outside the secured perimeter of KSC. The A3SB areas are approximately 0.6 miles apart, and were developed as Shiffler's Grocery Store and Service Station (west site) and as a residence (east site) prior to acquisition by the National Aeronautics and Space Administration (NASA) in 1963. Both areas were used by the Bendix Company in support of NASA as chemical laboratories from 1963 through 1969. Both of the buildings were demolished by 1987. The west portion of the site was used by the US Fish & Wildlife Service (F&W) in support of the Merritt Island National Wildlife Refuge (MINWR) for parking at the entrance to the Hammock Trails from 1969 to the present. The east portion of the site was used for intermittent suspect materials staging in the early 1990s and is still used as an apiary location, but is otherwise no longer active. In support of the NASA HSWA permit requirements, this site was identified as Potential Release Location (PRL) 218 and a Solid Waste Management Unit (SWMU) Assessment (SA) was conducted in 2013. Confirmatory Sampling (CS) was recommended and approved by the KSC Remediation Team (KSCRT). Three locations of concern (LOCs) were identified and sampled at the site. The LOCs include two former chemical labs and a former suspect staging area. The CS was conducted in March of 2015 at three locations by means of Direct Push Technology (DPT) groundwater sampling and at one location for soil sampling. The samples were collected and analyzed in accordance with the approved CS Work Plan. There were no exceedances of criteria detected in any of the samples from the three LOCs. The results of this investigation indicate that past and/or present operations have not negatively impacted environmental media at the A3SB. Based upon no confirmed groundwater detections above GCTLs and no

  3. Removal Action Workplan for the 105-DR and 105-F Building Interim Safe Storage Projects and Ancillary Buildings

    International Nuclear Information System (INIS)

    Rodovsky, T. J.

    1999-01-01

    This document is the removal action workplan (RAW) for the 105-DR and 105-F Reactor Buildings and ancillary facilities. These buildings and facilities are located in the 100-D/DR and 100-F Areas of the Hanford Site in Benton County, Washington, which is owned and operated by the U.S. Department of Energy (DOE). The 100 Areas (including 100-D/DR and 100-F Areas) of the Hanford Site were placed on the U.S. Environmental Protection Agency's (EPA) National Priorities List under the Comprehensive Environmental Response, Compensation,and Liability Act of 1980 (CERCLA). DOE has determined that hazardous substances in the 105-DR and 105-F Reactor Buildings and four ancillary facilities present a potential threat to human health or the environment DOE has also determined that a non-time critical removal action is warranted at these facilities

  4. Planning of Low-rise Urban Housing Areas

    DEFF Research Database (Denmark)

    Svensson, O.

    In many countries industrialization of house building has led to the building of large, monotonous housing areas with high-rise construction. In Denmark, however, smaller, varied housing areas with low-rise construction and urban features have become predominant. This report contains guidelines...... for the planning of such housing areas....

  5. 2017 Building Technologies Office Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-11-01

    The 2017 Building Technologies Office Peer Review Report summarizes the feedback submitted by reviewers for the 109 Building Technologies Office (BTO) projects presented at the 2017 BTO Peer Review. The report presents an overview of the goals and activities under each technology program area, a summary of project scores for each program, and a brief analysis of general evaluation trends within each program area or its constituent subprograms.

  6. Buildings Interoperability Landscape

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephan, Eric G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-12-31

    Through its Building Technologies Office (BTO), the United States Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE-EERE) is sponsoring an effort to advance interoperability for the integration of intelligent buildings equipment and automation systems, understanding the importance of integration frameworks and product ecosystems to this cause. This is important to BTO’s mission to enhance energy efficiency and save energy for economic and environmental purposes. For connected buildings ecosystems of products and services from various manufacturers to flourish, the ICT aspects of the equipment need to integrate and operate simply and reliably. Within the concepts of interoperability lie the specification, development, and certification of equipment with standards-based interfaces that connect and work. Beyond this, a healthy community of stakeholders that contribute to and use interoperability work products must be developed. On May 1, 2014, the DOE convened a technical meeting to take stock of the current state of interoperability of connected equipment and systems in buildings. Several insights from that meeting helped facilitate a draft description of the landscape of interoperability for connected buildings, which focuses mainly on small and medium commercial buildings. This document revises the February 2015 landscape document to address reviewer comments, incorporate important insights from the Buildings Interoperability Vision technical meeting, and capture thoughts from that meeting about the topics to be addressed in a buildings interoperability vision. In particular, greater attention is paid to the state of information modeling in buildings and the great potential for near-term benefits in this area from progress and community alignment.

  7. Characterization of children hospitalized with traumatic brain injuries after building falls.

    Science.gov (United States)

    Loftus, Kirsten V; Rhine, Tara; Wade, Shari L; Pomerantz, Wendy J

    2018-04-10

    Unintentional falls cause a substantial proportion of pediatric traumatic brain injury (TBI), with building falls carrying particularly high risk for morbidity and mortality. The cohort of children sustaining building fall-related TBI has not been well-examined. We sought to characterize children hospitalized with building fall-related TBIs and evaluate if specific factors distinguished these children from children hospitalized with TBI due to other fall mechanisms. We secondarily assessed if TBI severity among children injured due to a building fall varied between children from urban versus non-urban areas. This was a secondary analysis of the Pediatric Health Information System (PHIS), an administrative database from pediatric hospitals. We identified children codes. Urban versus non-urban status was determined using PHIS-assigned Rural-Urban Commuting Area codes. Injury severity (i.e. Injury Severity Score (ISS) and head Abbreviated Injury Scale (AIS) score) were calculated. Head AIS scores were dichotomized into minor/moderate (1-2) and serious/severe (3-6) for analysis. Frequencies, descriptive statistics, Chi-square analysis, and Mann-Whitney U analysis characterized populations and determined group differences. The study cohort included 23,813 children, of whom 933 (3.9%) fell from buildings. Within the building fall cohort, 707 (75.8%) resided in urban areas, 619 (66.3%) were male, 513 (55.0%) were white, and 528 (56.6%) had government insurance; the mean age was 3.8 years (SD 2.9). There was a larger proportion of children with serious/severe TBI among those injured from building falls relative to other falls (63.4% vs 53.9%, p building falls, those from non-urban areas were more likely to sustain a serious/severe TBI relative to urban children (58.9% vs 53.6%, p buildings falls with TBI sustained more severe injuries relative to other fall types. Although a majority of children hospitalized with building fall related-TBIs were from urban areas, those

  8. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1989-01-01

    In conventional dynamic structural analyses for determining dynamic system response for various locations at which components are installed inside the structures it is common practice (in order to simplify analytical effort) to assume that the anchorage (anchor plate, anchor bolts or throughbolts, concrete and reinforcement in the area of bound) has rigid body characteristics and that the building structure itself does not display any local response of its own. The influence of the stiffness of the anchor plate as well anchor bolts and its stress level on the dynamic response is also neglected. For a large number of anchoring systems, especially for all those components and systems having only a small mass, this assumption is certainly appropriate. At some locations, particularly at points where heavy components are anchored or when loading input has been increased, this can lead to local loading of the anchor system as well as of the building structure well into the nonlinear range. Often, verification of capability to accommodate these loads is not possible without changing the wall thicknesses or increasing the percentage of reinforcement. Since the presence of linear or nonlinear effects can be expected to result in energy dissipation (increase in damping capacity and also a change in the stiffness of the coupled system) it must be assumed that the dynamic response between the theoretical coupling point A and the real connection point B of the component on the anchor plate can be considerably altered. Some changes of the dynamic response in the connection point B have to be expected generally even in cases of linear-elastic loading of the anchorage. Using typical anchoring systems as an example, the influence of consideration of nonlinear effects in the anchorage area of a typical anchor plate on the dynamic response as well as the conservatism of conventional analytical approaches are investigated

  9. Net-zero building

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2013-01-01

    Full Text Available In its experimental work on research and development of innovative technologies for low income housing on the Innovation Site on the CSIR campus in Pretoria, the Building Science and Technology (BST) competence area identified a number...

  10. Analysis of gamma ray intensity on the S/C vent pipes area in the unit 2 reactor building of the Fukushima Daiichi Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Choi, Young Soo; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The robot is equipped with cameras, a dosimeter, and 2 DOF (degree of freedom) manipulation arms. It loads a small vehicle equipped with a camera that can access and inspect narrow areas. TEPCO is using the four-legged walking robot to inspect the suppression chamber (S/C) area of the unit 2 reactor building basement in the Fukushima Daiichi Nuclear Power Plant. The robot carried out 6 missions for about four months, from 11 December, 2012 to 15 March, 2013, where it examined an evidence of a leakage of radioactivity contaminated water in the S/C area of unit 2 reactor building. When a camera's signal processing unit, which is consist of ASIC and FPGA devices manufactured by a CMOS fabrication process, is exposed to a higher dose rate gamma ray, the speckle distribution in the camera image increase more. From the inspection videos, released by TEPCO, of the underground 8 vent pipes in the unit 2 reactor building, we analyzed the speckle distribution from the high dose-rate gamma rays. Based on the distribution of the speckle, we attempted to characterize the vent pipe with much radioactivity contaminated materials among the eight vent pipes connected to the PCV. The numbers of speckles viewed in the image of a CCD (or CMOS) camera are related to an intensity of the gamma ray energy emitted by a nuclear fission reaction from radioactivity materials. The numbers of speckles generated by gamma ray irradiation in the camera image are calculated by an image processing technique. Therefore, calculating the speckles counts, we can determine the vent pipe with relatively most radioactivity-contaminated materials among the other vent pipes. From the comparison of speckles counts calculated in the inspection image of the vent pipe with the speckles counts extracted by gamma ray irradiation experiment of the same small vehicle camera model loaded with the four-legged walking robot, we can qualitatively estimate the gamma ray dose-rate in the S/C vent pipe area of the

  11. Characterization report for Area 23, Building 650 Leachfield, Corrective Action Unit Number 94, Nevada Test Site. Revision 1

    International Nuclear Information System (INIS)

    1998-01-01

    Corrective Action Unit (CAU) Number 94, Building 650 Leachfield, is an historic laboratory disposal unit located in Area 23 at the Nevada Test Site (NTS) in Nye County, Nevada. The objectives of this project were twofold: characterize subsurface conditions at the CAU with respect to the on-site disposal unit, and provide sufficient information to develop a closure strategy for the leachfield. To this end, subsurface sampling was conducted in the vicinity of the piping above the distribution box, under and around the distribution box, and within the leachfield

  12. Characterization report for Area 23, Building 650 Leachfield, Corrective Action Unit Number 94, Nevada Test Site. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-27

    Corrective Action Unit (CAU) Number 94, Building 650 Leachfield, is an historic laboratory disposal unit located in Area 23 at the Nevada Test Site (NTS) in Nye County, Nevada. The objectives of this project were twofold: characterize subsurface conditions at the CAU with respect to the on-site disposal unit, and provide sufficient information to develop a closure strategy for the leachfield. To this end, subsurface sampling was conducted in the vicinity of the piping above the distribution box, under and around the distribution box, and within the leachfield.

  13. Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Tryggvason, T.

    1998-01-01

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution will be introduced for improvement of the predictions of both the energy consumption and the indoor environment. The building energy performance...... simulation program requires a detailed description of the energy flow in the air movement which can be obtained by a CFD program. The paper describes an energy consumption calculation in a large building, where the building energy simulation program is modified by CFD predictions of the flow between three...... zones connected by open areas with pressure and buoyancy driven air flow. The two programs are interconnected in an iterative procedure. The paper shows also an evaluation of the air quality in the main area of the buildings based on CFD predictions. It is shown that an interconnection between a CFD...

  14. Semi-automatic building extraction in informal settlements from high-resolution satellite imagery

    Science.gov (United States)

    Mayunga, Selassie David

    The extraction of man-made features from digital remotely sensed images is considered as an important step underpinning management of human settlements in any country. Man-made features and buildings in particular are required for varieties of applications such as urban planning, creation of geographical information systems (GIS) databases and Urban City models. The traditional man-made feature extraction methods are very expensive in terms of equipment, labour intensive, need well-trained personnel and cannot cope with changing environments, particularly in dense urban settlement areas. This research presents an approach for extracting buildings in dense informal settlement areas using high-resolution satellite imagery. The proposed system uses a novel strategy of extracting building by measuring a single point at the approximate centre of the building. The fine measurement of the building outlines is then effected using a modified snake model. The original snake model on which this framework is based, incorporates an external constraint energy term which is tailored to preserving the convergence properties of the snake model; its use to unstructured objects will negatively affect their actual shapes. The external constrained energy term was removed from the original snake model formulation, thereby, giving ability to cope with high variability of building shapes in informal settlement areas. The proposed building extraction system was tested on two areas, which have different situations. The first area was Tungi in Dar Es Salaam, Tanzania where three sites were tested. This area is characterized by informal settlements, which are illegally formulated within the city boundaries. The second area was Oromocto in New Brunswick, Canada where two sites were tested. Oromocto area is mostly flat and the buildings are constructed using similar materials. Qualitative and quantitative measures were employed to evaluate the accuracy of the results as well as the performance

  15. MULTIDIRECTIONAL BUILDING DETECTION IN AERIAL IMAGES WITHOUT SHAPE TEMPLATES

    Directory of Open Access Journals (Sweden)

    A. Manno-Kovacs

    2013-05-01

    Full Text Available The aim of this paper is to exploit orientation information of an urban area for extracting building contours without shape templates. Unlike using shape templates, these given contours describe more variability and reveal the fine details of the building outlines, resulting in a more accurate detection process, which is beneficial for many tasks, like map updating and city planning. According to our assumption, orientation of the closely located buildings is coherent, it is related to the road network, therefore adaptation of this information can lead to more efficient building detection results. The introduced method first extracts feature points for representing the urban area. Orientation information in the feature point neighborhoods is analyzed to define main orientations. Based on orientation information, the urban area is classified into different directional clusters. The edges of the classified building groups are then emphasized with shearlet based edge detection method, which is able to detect edges only in the main directions, resulting in an efficient connectivity map. In the last step, with the fusion of the feature points and connectivity map, building contours are detected with a non-parametric active contour method.

  16. Automatic 3d Building Model Generations with Airborne LiDAR Data

    Science.gov (United States)

    Yastikli, N.; Cetin, Z.

    2017-11-01

    LiDAR systems become more and more popular because of the potential use for obtaining the point clouds of vegetation and man-made objects on the earth surface in an accurate and quick way. Nowadays, these airborne systems have been frequently used in wide range of applications such as DEM/DSM generation, topographic mapping, object extraction, vegetation mapping, 3 dimensional (3D) modelling and simulation, change detection, engineering works, revision of maps, coastal management and bathymetry. The 3D building model generation is the one of the most prominent applications of LiDAR system, which has the major importance for urban planning, illegal construction monitoring, 3D city modelling, environmental simulation, tourism, security, telecommunication and mobile navigation etc. The manual or semi-automatic 3D building model generation is costly and very time-consuming process for these applications. Thus, an approach for automatic 3D building model generation is needed in a simple and quick way for many studies which includes building modelling. In this study, automatic 3D building models generation is aimed with airborne LiDAR data. An approach is proposed for automatic 3D building models generation including the automatic point based classification of raw LiDAR point cloud. The proposed point based classification includes the hierarchical rules, for the automatic production of 3D building models. The detailed analyses for the parameters which used in hierarchical rules have been performed to improve classification results using different test areas identified in the study area. The proposed approach have been tested in the study area which has partly open areas, forest areas and many types of the buildings, in Zekeriyakoy, Istanbul using the TerraScan module of TerraSolid. The 3D building model was generated automatically using the results of the automatic point based classification. The obtained results of this research on study area verified that automatic 3D

  17. AUTOMATIC 3D BUILDING MODEL GENERATIONS WITH AIRBORNE LiDAR DATA

    Directory of Open Access Journals (Sweden)

    N. Yastikli

    2017-11-01

    Full Text Available LiDAR systems become more and more popular because of the potential use for obtaining the point clouds of vegetation and man-made objects on the earth surface in an accurate and quick way. Nowadays, these airborne systems have been frequently used in wide range of applications such as DEM/DSM generation, topographic mapping, object extraction, vegetation mapping, 3 dimensional (3D modelling and simulation, change detection, engineering works, revision of maps, coastal management and bathymetry. The 3D building model generation is the one of the most prominent applications of LiDAR system, which has the major importance for urban planning, illegal construction monitoring, 3D city modelling, environmental simulation, tourism, security, telecommunication and mobile navigation etc. The manual or semi-automatic 3D building model generation is costly and very time-consuming process for these applications. Thus, an approach for automatic 3D building model generation is needed in a simple and quick way for many studies which includes building modelling. In this study, automatic 3D building models generation is aimed with airborne LiDAR data. An approach is proposed for automatic 3D building models generation including the automatic point based classification of raw LiDAR point cloud. The proposed point based classification includes the hierarchical rules, for the automatic production of 3D building models. The detailed analyses for the parameters which used in hierarchical rules have been performed to improve classification results using different test areas identified in the study area. The proposed approach have been tested in the study area which has partly open areas, forest areas and many types of the buildings, in Zekeriyakoy, Istanbul using the TerraScan module of TerraSolid. The 3D building model was generated automatically using the results of the automatic point based classification. The obtained results of this research on study area verified

  18. The pre-fabrication of building facades

    CERN Document Server

    Rangel, Bárbara; Faria, José

    2017-01-01

    This book compares two buildings with different technologies and distinct environment from the combined viewpoints of civil engineering and architecture. The first is the most recent building of Columbia University in New York, the Northwest Science Building, a project designed by Rafael Moneo and Dan Brodkin of Ove Arup. The second one is the Burgo Tower in Oporto, by Eduardo Souto Moura and Rui Furtado of AFA, a building that brings a new perspective to the use of prefabrication technologies with local traditional construction systems. With the detailed analyses of recognized researchers in civil engineering and architecture, this book is a reflection upon the problems and solutions in the design and construction process of a prefabricated building system. This volume, like those to follow, brings together, building research and building design practice to enhance the knowledge of complementarity areas involved in construction, engineering and architecture. This is the first book in a new series "Building R...

  19. Method for building a nuclear power plant and layout thereof

    International Nuclear Information System (INIS)

    Matsuura, Tadashi; Ushiroda, Kouchi; Tajiri, Akinori; Yoshida, Naoto; Takeda, Masakado; Makita, Tasuo; Maezawa, Sumito; Yoshizaki, Masatoshi.

    1997-01-01

    The present invention relates to a technical field of building a nuclear power plant, and its technical issue is to reduce the scale of investment for cranes to be used in building a plurality of nuclear power plant units. In order to resolve the technical issue, in the present invention, a nuclear power plant building method is employed in building a plurality of nuclear plant units in which while an earlier building unit out of the plurality of units which is started to be built earlier is being built, a later building unit that is to be started to be built later than the earlier building unit is started to be built, and in which a common mobile crane is adapted to move between a crane operating area for the earlier building unit and a crane operating area for the later building unit so that the common mobile crane ban be used in building the plurality of units. The present invention is primarily intended for the construction of a nuclear power plant. (author) figs

  20. Sustainable Building Life Cycle Design

    Directory of Open Access Journals (Sweden)

    Ginzburg Alexander

    2016-01-01

    Full Text Available The current building life cycle management system in the Russian Federation is a family of discrete subsystems that exist independently for different building life cycle stages. In this situation building reliability and sustainable functioning are out of the question. The implementation of a united information model (BIM-model intended to describe building entire life cycle will allow to raise the sustainability, but this will happen only if goals and concerns of all participants of the project process are properly coordinated. An important figure of process sustainability is the organizational and technological reliability (OTR that describes the possibility of a system to reach a goal. In case of building life cycle design, the economical efficiency of a building can be considered as the goal. The required technical, ecological, organizational, and other parameters form a complex of constraints that determine the area of allowable values for building functioning. In its broad meaning, OTR may be understood as the probability of receiving an economical effect based on the value of organizational and economical reliability (OER.

  1. Joint China-United States Report for Year 1 Insulation Materials and Systems Project Area Clean Energy Research Center Building Energy Efficiency (CERC-BEE)

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, Therese K [ORNL; Biswas, Kaushik [ORNL; Song, Bo [China Academy of Building Research; Zhang, Sisi [China Academy of Building Research

    2012-08-01

    fire safety. A related issue is the degree to which new standards are adopted and enforced. In the U.S., standards are developed using a consensus process, and local government agencies are free to implement these standards or to ignore them. For example, some U.S. states are still using 2003 versions of the building efficiency standards. There is also a great variation in the degree to which the locally adopted standards are enforced in different U.S. cities and states. With a more central process in China, these issues are different, but possible impacts of variable enforcement efficacy may also exist. Therefore, current building codes in China will be compared to the current state of building fire-safety and energy-efficiency codes in the U.S. and areas for possible improvements in both countries will be explored. In particular, the focus of the applications in China will be on green buildings. The terminology of 'green buildings' has different meanings to different audiences. The U.S. research is interested in both new, green buildings, and on retrofitting existing inefficient buildings. An initial effort will be made to clarify the scope of the pertinent wall insulation systems for these applications.

  2. Building Maintenance. Reading and Language Activities.

    Science.gov (United States)

    Kessman, William A.

    The student manual has been designed primarily for beginning students in a high school level vocational program in building maintenance. A workbook for special needs students, the document does not cover all areas of custodial training but has been written for the purpose of refining the basic skills of reading comprehension, vocabulary building,…

  3. Construction of 'Monju' maintenance and waste disposal building by Shimizu Corporation

    International Nuclear Information System (INIS)

    Baba, Ikuo

    1994-01-01

    The scale of the building, the use, the outline of construction works and the construction processes of the maintenance and waste disposal building among the facilities of the fast breeder prototype reactor 'Monju' are described, and the construction technology which was adopted for ensuring the quality, the construction period and the safety, the state of carrying out quality assurance activity and so on are reported. Moreover, the building works and the electricity works are mentioned, and the examples that were devised on building side for smoothly advancing later electricity side works are introduced, further, as a feature work, the work of erecting the steel framework that constitutes the large space for repair area is explained. The arrangement of buildings, and the scale and the structure of the maintenance and waste disposal building which is a reinforced concrete building, partly steel framework reinforced concrete building, with four stories above ground and four stories underground and the total floor area of 14,354m 2 are described. Liquid waste treatment and washing facilities are in underground, and repair area, solid waste treatment and electric and air conditioning facilities are on above ground floors. (K.I.)

  4. Solar building study. Summary report. St. Michael`s Close, Harlow

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-31

    Designed and developed by Harlow Council as an admirable attempt to reduce the energy consumption of its large housing stock, this building represents a quality alternative to the bland stereotype of local authority housing. Well liked for its appearances and other amenity benefits the building in practice is a failure. This failure, which manifests itself in extreme and unnecessary overheating of habitable areas of the building, originates in the lack of division between the conservatory and the rest of the building. Any condition that exists in the former area quickly transmits itself to the latter. The dropping of dividing doors and glazing, that would have enabled the isolation of the conservatory from adjacent habitable areas, was a decision made during the design stage on cost grounds for a saving of approximately 2000 pounds. (author)

  5. Seismic strengthening of building 111 at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Eli, M.; Coats, D.; Freeland, G.; Kamath, M.

    1991-01-01

    Since being designed and constructed in the late 1960s, the Director's Building (Building 111) at Lawrence Livermore National Laboratory (LLNL) has been evaluated for 1988 seismic criteria and has been upgraded to withstand a major earthquake in the Livermore area. During and immediately after a large earthquake in the Livermore area, Building 111 occupants would be able to exit safely without loss of life. Building 111 itself would be severely damaged, but would not collapse. Highlights of the seismic upgrade design criteria and of the design, analyses, and construction that resulted are presented in this paper

  6. Better Buildings Neighborhood Program: BetterBuildings Lowell Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Heslin, Thomas

    2014-01-31

    Historic Board, which has jurisdiction in the NHP. The Historic Board was cooperative with any exterior renovations as long as they were not changing the existing aesthetics of the property. If we were replacing a rooftop condenser it needed to be placed where the existing rooftop condenser was located. Receiving proper approval from the Historic Board for any external energy conservation measures was known by all the participating contractors. One area of the retrofits that was contentious regarded venting of the new HVAC equipment. Installing external stacks was not allowed so the contractors had to negotiate with the Historic Board regarding the proper way to vent the equipment that met the needs mechanically and aesthetically. Overall BetterBuildings Lowell was successful at implementing energy and cost saving measures into 31 commercial properties located within the NHP. The 31 retrofits had 1,554,768 square feet of commercial and multifamily housing and a total predicted energy savings exceeding 22,869 a year. Overall the City of Lowell achieved its target goals and is satisfied with the accomplishments of the BetterBuildings program. The City will continue to pursue energy efficient programs and projects.

  7. Unintended anchors: Building rating systems and energy performance goals for U.S. buildings

    International Nuclear Information System (INIS)

    Klotz, Leidy; Mack, Daniel; Klapthor, Brent; Tunstall, Casey; Harrison, Jennilee

    2010-01-01

    In the U.S., where buildings account for 40% of energy use, commercial buildings use more energy per unit area than ever before. However, exemplary buildings demonstrate the feasibility of much better energy performance at no additional first cost. This research examines one possible explanation for this inconsistency. The aim is to investigate whether the anchoring bias, which refers to our tendency to gravitate towards a pre-defined standard regardless of its relevance, influences energy performance goals in building design. The scope examines professionals who help set energy performance goals for U.S. buildings. Prior to being asked to set an energy performance goal, these professionals were randomly directed to one of three series of questions. One series set an anchor of 90% energy reduction beyond standard practice, one set a 30% anchor, and one set no anchor. Respondents exposed to the 90% anchor, and respondents exposed to no anchor at all, set higher energy performance goals than respondents exposed to the 30% anchor. These results suggest that building rating systems that only reward incremental energy improvements may inadvertently create anchors, thereby discouraging more advanced energy performance goals and inhibiting energy performance that is technically and economically feasible.

  8. LCG/AA build infrastructure

    International Nuclear Information System (INIS)

    Hodgkins, Alex Liam; Diez, Victor; Hegner, Benedikt

    2012-01-01

    The Software Process and Infrastructure (SPI) project provides a build infrastructure for regular integration testing and release of the LCG Applications Area software stack. In the past, regular builds have been provided using a system which has been constantly growing to include more features like server-client communication, long-term build history and a summary web interface using present-day web technologies. However, the ad-hoc style of software development resulted in a setup that is hard to monitor, inflexible and difficult to expand. The new version of the infrastructure is based on the Django Python framework, which allows for a structured and modular design, facilitating later additions. Transparency in the workflows and ease of monitoring has been one of the priorities in the design. Formerly missing functionality like on-demand builds or release triggering will support the transition to a more agile development process.

  9. Building Integrated Active Flow Control: Improving the Aerodynamic Performance of Tall Buildings Using Fluid-Based Aerodynamic Modification

    Science.gov (United States)

    Menicovich, David

    By 2050 an estimated 9 billion people will inhabit planet earth and almost all the growth in the next 40 years will be in urban areas putting tremendous pressure on creating sustainable cities. The rapid increase in population, rise in land value and decrease in plot sizes in cities around the world positions tall or more importantly slender buildings as the best suited building typology to address the increasingly critical demand for space in this pressing urbanization trend. However, the majority of new tall building urban developments have not followed principles of environmental and/or sustainable design and incentives to innovate, both technological and economic, are urgently required. The biggest climatic challenge to the design, construction and performance of tall buildings is wind sensitivity. This challenge is further emphasized seeing two market driven trends: on one hand as urban population grows, land value rises while plot sizes decrease; on the other, more cost effective modular construction techniques are introducing much lighter tall building structures. The combination of the two suggests a potential increase in the slenderness ratio of tall buildings (typically less than 6:1 but stretching to 20:1 in the near future) where not-so-tall but much lighter buildings will be the bulk of new construction in densely populated cities, providing affordable housing in the face of fast urbanization but also introducing wind sensitivity which was previously the problem of a very limited number of super tall buildings to a much larger number of buildings and communities. The proposed research aims to investigate a novel approach to the interaction between tall buildings and their environment. Through this approach the research proposes a new relationship between buildings and the flows around, through and inside them, where buildings could adapt to better control and manage the air flow around them, and consequently produce significant opportunities to reduce

  10. Removal Action Work Plan for 105-DR and 105-F Building Interim Safe Storage Projects and Ancillary Buildings

    International Nuclear Information System (INIS)

    Morton, M.R.

    2000-01-01

    This document contains the removal action work plan for the 105-DR and 105-F Reactor buildings and ancillary facilities. These buildings and facilities are located in the 100-D/DR and 100-F Areas of the Hanford Site, which is owned and operated by the US Department of Energy (DOE), in Benton County, Washington. The 100 Areas (including the 100-D/DR and 100-F Areas) of the Hanford Site were placed on the US Environmental Protection Agency's (EPA's) National Priorities List under the ''Comprehensive Environmental Response, Compensation, and Liability Act of 1980'' (CERCLA). The DOE has determined that hazardous substances in the 105-DR and 105-F Reactor buildings and four ancillary facilities present a potential threat to human health or the environment. The DOE has also determined that a non-time critical removal action is warranted at these facilities. Alternatives for conducting a non-time critical removal action were evaluated in the ''Engineering Evaluation/Cost Analysis for the 105-DR and 105-F Reactor Facilities and Ancillary Facilities'' (DOE-RL 1998a). The engineering evaluation/cost analysis (EE/CA) resulted in the recommendation to decontaminate and demolish the contaminated reactor buildings (except for the reactor blocks) and the ancillary facilities and to construct a safe storage enclosure (SSE) over the reactor blocks. The recommendation was approved in an action memorandum (Ecology et al. 1998) signed by the Washington State Department of Ecology (Ecology), EPA, and DOE. The DOE is the agency responsible for implementing the removal actions in the 105-D/DR and 105-F Areas. Ecology is the lead regulatory agency for facilities in the 100-D/DR Area, and EPA is the lead regulatory agency for facilities in the 100-F Area. The term ''lead regulator agency'' hereinafter, refers to these authorities. This removal action work plan supports implementation of the non-time critical removal action

  11. Re-conceiving building design quality: A review of building users in their social context.

    Science.gov (United States)

    Watson, Kelly J; Evans, James; Karvonen, Andrew; Whitley, Tim

    2016-05-01

    Considerable overlap exists between post-occupancy research evaluating building design quality and the concept of 'social value', popularised by its recent application to issues of the public realm. To outline this potential research agenda, the paper reviews design quality research on buildings in relation to users and their social context where the term 'social context' refers to building user group dynamics, a combination of organisational cultures, management strategies, and social norms and practices. The review is conducted across five key building types, namely housing, workplaces, healthcare, education, and the retail/service sector. Research commonalities and gaps are identified in order to build a more comprehensive picture of the design quality literature and its handling of users in their social context. The key findings concerning each building type are presented visually. It is concluded that the design quality field comprises a patchwork of relatively isolated studies of various building types, with significant potential for theoretical and empirical development through interdisciplinary collaboration. Users tend to be conceived as anonymous and autonomous individuals with little analysis of user identity or interaction. Further, the contextual impact of user group dynamics on the relationship between building design and building user is rarely addressed in the literature. Producing a more nuanced understanding of users in situ is proposed as an important area for future design quality research.

  12. 700 Area

    Data.gov (United States)

    Federal Laboratory Consortium — The 700 Area of the Hanford Site is located in downtown Richland.Called the Federal Office Building, the Richland Operations Site Manager and the Richland Operations...

  13. Building Maintenance: Introduction. Units of Instruction. Teacher's Guide. First Edition.

    Science.gov (United States)

    Barnes, Bill

    This volume, the first in a series of publications that will provide entry-level competencies in the area of building maintenance, is designed as an introduction. The seven instructional units cover these areas in the shop program: (1) introduction to building maintenance, (2) leadership development, (3) personal development, (4) job application…

  14. Comparison of Indoor Mercury Vapor in Common Areas of Residential Buildings with Outdoor Levels in a Community Where Mercury Is Used for Cultural Purposes

    Science.gov (United States)

    Garetano, Gary; Gochfeld, Michael; Stern, Alan H.

    2006-01-01

    Elemental mercury has been imbued with magical properties for millennia, and various cultures use elemental mercury in a variety of superstitious and cultural practices, raising health concerns for users and residents in buildings where it is used. As a first step in assessing this phenomenon, we compared mercury vapor concentration in common areas of residential buildings versus outdoor air, in two New Jersey cities where mercury is available and is used in cultural practices. We measured mercury using a portable atomic absorption spectrometer capable of quantitative measurement from 2 ng/m3 mercury vapor. We evaluated the interior hallways in 34 multifamily buildings and the vestibule in an additional 33 buildings. Outdoor mercury vapor averaged 5 ng/m3; indoor mercury was significantly higher (mean 25 ng/m3; p < 0.001); 21% of buildings had mean mercury vapor concentration in hallways that exceeded the 95th percentile of outdoor mercury vapor concentration (17 ng/m3), whereas 35% of buildings had a maximum mercury vapor concentration that exceeded the 95th percentile of outdoor mercury concentration. The highest indoor average mercury vapor concentration was 299 ng/m3, and the maximum point concentration was 2,022 ng/m3. In some instances, we were able to locate the source, but we could not specifically attribute the elevated levels of mercury vapor to cultural use or other specific mercury releases. However, these findings provide sufficient evidence of indoor mercury source(s) to warrant further investigation. PMID:16393659

  15. A New Building-Integrated Wind Turbine System Utilizing the Building

    Directory of Open Access Journals (Sweden)

    Jeongsu Park

    2015-10-01

    Full Text Available This paper proposes an innovative building-integrated wind turbine (BIWT system by directly utilizing the building skin, which is an unused and unavailable area in all conventional BIWT systems. The proposed system has been developed by combining a guide vane that is able to effectively collect the incoming wind and increase its speed and a rotor with an appropriate shape for specific conditions. To this end, several important design issues for the guide vane as well as the rotor were thoroughly investigated and accordingly addressed in this paper. A series of computational fluid dynamics (CFD analyses was performed to determine the optimal configuration of the proposed system. Finally, it is demonstrated from performance evaluation tests that the prototype with the specially designed guide vane and rotor for the proposed BIWT system accelerates the wind speed to a sufficient level and consequently increases the power coefficient significantly. Thus, it was confirmed that the proposed system is a promising environment-friendly energy production system for urban areas.

  16. Deformations of temporary wooden supports used to reduce building deflections in mining areas

    Science.gov (United States)

    Gromysz, Krzysztof

    2018-04-01

    Temporary supports, consisting of a stack of wooden elements and a hydraulic jack, are used in the process of removing deflections in buildings with one to three aboveground floors in mining areas. During uneven raising, the supports are loaded monotonically, unloaded and loaded cyclically. Laboratory tests were designed for the supports. For the investigated range of loads of 0 to 400 kN, under a growing load, a linear relationship exists between a load and the change in the stack length, which signifies that the deformations of wooden elements and displacements related to their mutual interactions increase proportionally. A seemingly higher stack stiffness is seen at the beginning of the unloading process and for cyclical loads, meaning that in this phase of loading, the material deformation of the wooden elements and the jack is responsible for changing the jack length in this load phase, with a negligible presence of mutual displacements of wooden elements. The support, after being unloaded, returns to the initial position and its permanent deformations are not observed. The stiffness of a temporary support decreases as the height of the stack of wooden elements increases.

  17. Deformations of temporary wooden supports used to reduce building deflections in mining areas

    Directory of Open Access Journals (Sweden)

    Gromysz Krzysztof

    2018-01-01

    Full Text Available Temporary supports, consisting of a stack of wooden elements and a hydraulic jack, are used in the process of removing deflections in buildings with one to three aboveground floors in mining areas. During uneven raising, the supports are loaded monotonically, unloaded and loaded cyclically. Laboratory tests were designed for the supports. For the investigated range of loads of 0 to 400 kN, under a growing load, a linear relationship exists between a load and the change in the stack length, which signifies that the deformations of wooden elements and displacements related to their mutual interactions increase proportionally. A seemingly higher stack stiffness is seen at the beginning of the unloading process and for cyclical loads, meaning that in this phase of loading, the material deformation of the wooden elements and the jack is responsible for changing the jack length in this load phase, with a negligible presence of mutual displacements of wooden elements. The support, after being unloaded, returns to the initial position and its permanent deformations are not observed. The stiffness of a temporary support decreases as the height of the stack of wooden elements increases.

  18. Modelling the probability of building fires

    Directory of Open Access Journals (Sweden)

    Vojtěch Barták

    2014-12-01

    Full Text Available Systematic spatial risk analysis plays a crucial role in preventing emergencies.In the Czech Republic, risk mapping is currently based on the risk accumulationprinciple, area vulnerability, and preparedness levels of Integrated Rescue Systemcomponents. Expert estimates are used to determine risk levels for individualhazard types, while statistical modelling based on data from actual incidents andtheir possible causes is not used. Our model study, conducted in cooperation withthe Fire Rescue Service of the Czech Republic as a model within the Liberec andHradec Králové regions, presents an analytical procedure leading to the creation ofbuilding fire probability maps based on recent incidents in the studied areas andon building parameters. In order to estimate the probability of building fires, aprediction model based on logistic regression was used. Probability of fire calculatedby means of model parameters and attributes of specific buildings can subsequentlybe visualized in probability maps.

  19. Geophysics: Building E5375 decommissioning, Aberdeen Proving Ground

    International Nuclear Information System (INIS)

    McGinnis, M.G.; McGinnis, L.D.; Miller, S.F.; Thompson, M.D.

    1992-08-01

    Building E5375 was one of ten potentially contaminated sites in the Canal Creek area of the Edgewood section of Aberdeen Proving Ground examined by a geophysical team from Argonne National Laboratory in April and May 1992. Noninvasive geophysical surveys, including magnetics, electrical resistivity, and ground-penetrating radar (GPR), were conducted around the perimeter of the building to guide a sampling program prior to decommissioning and dismantling. Several anomalies wear, noted: (1) An underground storage tank located 25 ft east of Building E5375 was identified with magnetic, resistivity, and GPR profiling. (2) A three-point resistivity anomaly, 12 ft east of the northeast comer of Building E5374 (which borders Building E5375) and 5 ft south of the area surveyed with the magnetometer, may be caused by another underground storage tank. (3) A 2,500-gamma magnetic anomaly near the northeast corner of the site has no equivalent resistivity anomaly, although disruption in GPR reflectors was observed. (4) A one-point magnetic anomaly was located at the northeast comer, but its source cannot be resolved. A chaotic reflective zone to the east represents the radar signature of Building E5375 construction fill

  20. Study of radiation dose reduction of buildings of different sizes and materials

    International Nuclear Information System (INIS)

    Furuta, Takuya; Takahashi, Fumiaki

    2015-01-01

    The dependence of radiation dose reduction on the sizes and materials of buildings was studied by numerical analyses using the Monte Carlo simulation code, PHITS. The dose rates inside the buildings were calculated by simulating gamma-ray transport from radioactive cesium deposited at the ground surface. Three building models were developed: the wooden house, the open-space concrete building, and the thin-wall building, to study the effect of building size and construction material on dose reduction inside these structures. Here the floor-area sizes of the building models were varied to clarify the influence of building configuration on dose reduction. The results demonstrated that the dose rates inside the buildings linearly decreased with increasing floor area on a logarithmic scale for all types of buildings considered. The calculated dose distribution inside a building indicated that the distance from the outer walls was a determining factor for the dose rate at each position in the building. The obtained tendency was verified by comparison with data reflecting the dose reduction of typical buildings in Japan. (author)

  1. Revegetation Plan for Areas of the Fitzner-Eberhardt Arid Lands Ecology Reserve Affected by Decommissioning of Buildings and Infrastructure and Debris Clean-up Actions

    Energy Technology Data Exchange (ETDEWEB)

    Downs, Janelle L.; Durham, Robin E.; Larson, Kyle B.

    2011-01-01

    The U.S. Department of Energy (DOE), Richland Operations Office is working to remove a number of facilities on the Fitzner Eberhardt Arid Lands Ecology Reserve (ALE), which is part of the Hanford Reach National Monument. Decommissioning and removal of buildings and debris on ALE will leave bare soils and excavated areas that need to be revegetated to prevent erosion and weed invasion. Four main areas within ALE are affected by these activities (DOE 2009;DOE/EA-1660F): 1) facilities along the ridgeline of Rattlesnake Mountain, 2) the former Nike missile base and ALE HQ laboratory buildings, 3) the aquatic research laboratory at Rattlesnake Springs area, and 4) a number of small sites across ALE where various types of debris remain from previous uses. This revegetation plan addresses the revegetation and restoration of those land areas disturbed by decommissioning and removal of buildings, facilities and associated infrastructure or debris removal. The primary objective of the revegetation efforts on ALE is to establish native vegetation at each of the sites that will enhance and accelerate the recovery of the native plant community that naturally persists at that location. Revegetation is intended to meet the direction specified by the Environmental Assessment (DOE 2009; DOE/EA-1660F) and by Stipulation C.7 of the Memorandum of Agreement (MOA) for the Rattlesnake Mountain Combined Community Communication Facility and InfrastructureCleanup on the Fitzner/Eberhardt Arid Lands Ecology Reserve, Hanford Site, Richland Washington(DOE 2009; Appendix B). Pacific Northwest National Laboratory (PNNL) under contract with CH2M Hill Plateau Remediation Company (CPRC) and in consultation with the tribes and DOE-RL developed a site-specific strategy for each of the revegetation units identified within this document. The strategy and implementation approach for each revegetation unit identifies an appropriate native species mix and outlines the necessary site preparation activities

  2. a Method for the Seamlines Network Automatic Selection Based on Building Vector

    Science.gov (United States)

    Li, P.; Dong, Y.; Hu, Y.; Li, X.; Tan, P.

    2018-04-01

    In order to improve the efficiency of large scale orthophoto production of city, this paper presents a method for automatic selection of seamlines network in large scale orthophoto based on the buildings' vector. Firstly, a simple model of the building is built by combining building's vector, height and DEM, and the imaging area of the building on single DOM is obtained. Then, the initial Voronoi network of the measurement area is automatically generated based on the positions of the bottom of all images. Finally, the final seamlines network is obtained by optimizing all nodes and seamlines in the network automatically based on the imaging areas of the buildings. The experimental results show that the proposed method can not only get around the building seamlines network quickly, but also remain the Voronoi network' characteristics of projection distortion minimum theory, which can solve the problem of automatic selection of orthophoto seamlines network in image mosaicking effectively.

  3. Modelling of settlement induced building damage

    NARCIS (Netherlands)

    Giardina, G.

    2013-01-01

    This thesis focuses on the modelling of settlement induced damage to masonry buildings. In densely populated areas, the need for new space is nowadays producing a rapid increment of underground excavations. Due to the construction of new metro lines, tunnelling activity in urban areas is growing.

  4. Analysis of Architectural Building Design Influences on Fire Spread in Densely Urban Settlement using Cellular Automata

    Science.gov (United States)

    Tambunan, L.; Salamah, H.; Asriana, N.

    2017-03-01

    This study aims to determine the influence of architectural design on the risk of fire spread in densely urban settlement area. Cellular Automata (CA) is used to analyse the fire spread pattern, speed, and the extent of damage. Four cells represent buildings, streets, and fields characteristic in the simulated area, as well as their flammability level and fire spread capabilities. Two fire scenarios are used to model the spread of fire: (1) fire origin in a building with concrete and wood material majority, and (2) fire origin in building with wood material majority. Building shape, building distance, road width, and total area of wall openings are considered constant, while wind is ignored. The result shows that fire spread faster in the building area with wood majority than with concrete majority. Significant amount of combustible building material, absence of distance between buildings, narrow streets and limited fields are factors which influence fire spread speed and pattern as well as extent of damage when fire occurs in the densely urban settlement area.

  5. Effects of bedrock type on the indoor radon concentrations at the office buildings in Gyeongju, Korea

    Directory of Open Access Journals (Sweden)

    Park Hee Chan

    2011-01-01

    Full Text Available This study measured the indoor radon concentrations at 23 administrative office buildings in Gyeongju, Korea, which consists of 23 administrative districts. Using the Korean geological information system, the type of bedrock under the administrative office buildings was identified and classified in 3 major types: granite, sedimentary rock, and sedimentary rock-based fault. The changes in the indoor concentrations at the 23 administrative office buildings were analyzed according to the type of bedrock. As a result, the radon concentration in the areas with the granite bedrock was generally higher than that in the region of two other types of bedrock. In addition, the radon concentration was evaluated according to surface area and construction timing of the building. The indoor radon concentration generally increased with decreasing surface area of the building, particularly in granite distributed areas. For a building aged more than 15 years, the radon concentration in the building in the granite area was much higher. For the building aged 1 or 2 years, the radon concentration was high regardless of the type of the bedrock due to radon emanation from the building material, such as concrete.

  6. use of the RESRAD-BUILD code to calculate building surface contamination limits

    International Nuclear Information System (INIS)

    Faillace, E.R.; LePoire, D.; Yu, C.

    1996-01-01

    Surface contamination limits in buildings were calculated for 226 Ra, 230 Th, 232 Th, and natural uranium on the basis of 1 mSv y -1 (100 mrem y -1 ) dose limit. The RESRAD-BUILD computer code was used to calculate these limits for two scenarios: building occupancy and building renovation. RESRAD-BUILD is a pathway analysis model designed to evaluate the potential radiological dose incurred by individuals working or living inside a building contaminated with radioactive material. Six exposure pathways are considered in the RESRAD-BUILD code: (1) external exposure directly from the source; (2) external exposure from materials deposited on the floor; (3) external exposure due to air submersion; (4) inhalation of airborne radioactive particles; (5) inhalation of aerosol indoor radon progeny; and (6) inadvertent ingestion of radioactive material, either directly from the sources or from materials deposited on the surfaces. The code models point, line, area, and volume sources and calculates the effects of radiation shielding, building ventilation, and ingrowth of radioactive decay products. A sensitivity analysis was performed to determine how variations in input parameters would affect the surface contamination limits. In most cases considered, inhalation of airborne radioactive particles was the primary exposure pathway. However, the direct external exposure contribution from surfaces contaminated with 226 Ra was in some cases the dominant pathway for building occupancy depending on the room size, ventilation rates, and surface release fractions. The surface contamination limits are most restrictive for 232 Th, followed by 230 Th, natural uranium, and 226 Ra. The results are compared with the surface contamination limits in the Nuclear Regulatory Commission's Regulatory Guide 1.86, which are most restrictive for 226 Ra and 230 Th, followed by 232 Th, and are least restrictive for natural uranium

  7. An analysis on energy efficiency initiatives in the building stock of Liege, Belgium

    International Nuclear Information System (INIS)

    Singh, Manoj Kumar; Mahapatra, Sadhan; Teller, Jacques

    2013-01-01

    Built environment is responsible for 60% of total energy consumption in European countries and 128 million BOE of primary energy in Belgium. The average energy consumption in the residential buildings of Belgium is 70% higher than the EU average and stands at 348 kW h/m 2 /year. Energy Performance Building Directive (EPBD) provides guidelines for energy performance analysis of buildings in Belgium. In this study, a holistic approach has been adopted to analyse the building stock of Liege, Belgium. This analysis is based on ‘General Socio-economic survey 2001’ and ‘Housing quality survey 2006 in Walloon region’ databases. It considers parameters such as buildings age, built-up area, type of heating system, type of fuel used, adjacency, insulation of roofs and walls and energy consumption etc. for an in depth analysis. This study concludes that about 69% of buildings which are constructed before 1945 needs serious renovation towards the improvement of roof and external wall insulation level. It then successfully identifies specific areas which need detailed study to evaluate the comfort status in the existing building stock, improvement of insulation level and its effect on heating energy consumption as well as the economic analysis on energy efficiency measurements. -- Highlights: •Energy efficiency studies of building stock of Liege, Belgium. •Energy Performance Building Directive is used as reference for analysis. •Buildings age, built-up area and energy consumption data are used for analysis. •Identifies the areas to improve energy efficiency of building stock

  8. Building the green way.

    Science.gov (United States)

    Lockwood, Charles

    2006-06-01

    Just five or six years ago, the term "green building" evoked visions of barefoot, tie-dyed, granola-munching denizens. There's been a large shift in perception. Of course, green buildings are still known for conserving natural resources by, for example, minimizing on-site grading, using alternative materials, and recycling construction waste. But people now see the financial advantages as well. Well-designed green buildings yield lower utility costs, greater employee productivity, less absenteeism, and stronger attraction and retention of workers than standard buildings do. Green materials, mechanical systems, and furnishings have become more widely available and considerably less expensive than they used to be-often cheaper than their standard counterparts. So building green is no longer a pricey experiment; just about any company can do it on a standard budget by following the ten rules outlined by the author. Reliable building-rating systems like the U.S. Green Building Council's rigorous Leadership in Energy and Environmental Design (LEED) program have done much to underscore the benefits of green construction. LEED evaluates buildings and awards points in several areas, such as water efficiency and indoor environmental quality. Other rating programs include the UK's BREEAM (Building Research Establishment's Environmental Assessment Method) and Australia's Green Star. Green construction is not simply getting more respect; it is rapidly becoming a necessity as corporations push it fully into the mainstream over the next five to ten years. In fact, the author says, the owners of standard buildings face massive obsolescence. To avoid this problem, they should carry out green renovations. Corporations no longer have an excuse for eschewing environmental and economic sustainability. They have at their disposal tools proven to lower overhead costs, improve productivity, and strengthen the bottom line.

  9. Enganging the past of the city through the conservation of heritage building

    Science.gov (United States)

    Nurliani Lukito, Yulia; Nurul Rizky, Amalia

    2017-12-01

    Built heritage is a physical representation of culture that provides a connection with the past and important for aesthetic and symbolic values for the city. The conservation of built heritage is a necessary not only to engage with the identity of but also to sustaining development in the city. However, heritage buildings are vulnerable to development and modernization. The paper examines a colonial building in Jakarta that has been converted into different functions through various levels of physical modifications. As a case study is Cut Meutia Mosque in Menteng, designed by a Dutch architect PAJ Moojen during the Dutch late colonial era. The building was initiated in 1912 as N.V. Bouwploeg, a Dutch architecture firm that developed the nearby residential area of New Gondangdia. The New Gondangdia, including Menteng as its central area, was developed according to modern garden city principles. During its lifetime, the building was used for different purposes such as a post office and a train company office. After Ali Sadikin's term as Governor of Jakarta, the building was converted into a mosque. The architecture of the building follows the Dutch Rationalist style but adapts to local climate such as a ventilation tower in the center of the building to regulate the temperature inside. Through historical and field research, this paper discusses the benefits and possible distortions of history manifest in the transformation of colonial buildings. Moreover, learning from the conservation of building heritage and urban area in the city may support the idea of livable memory of urban area and sustainable city.

  10. Coupled analysis of building damage due to tunneling

    NARCIS (Netherlands)

    Giardina, G.; Hendriks, M.A.N.; Rots, J.G.

    2009-01-01

    Excavation works in urban areas require a preliminary risk damage assessment. In historical cities, the prediction of building response to settlements is necessary to reduce the risk of damage of the architectural heritage. The current method used to predict the building damage due to ground

  11. Energy saving innovations in residential buildings. Energiesparende Innovationen im Eigenheim

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, E; Meyer, T

    1983-01-01

    Socio-economic studies have been carried out in the course of the ''Landstuhl demonstration project'' with the aim of evaluating supporting and hampering factors for the realization of energy saving measures, especially for the use of innovation techniques and the use of passive solar energy in residential buildings. The results of two opinion polls have been presented by means of standardized personal interviews with building-owners (in the whole Federal Republic and in the demonstration area) and with building experts (264 persons questioned). The evaluations of the results of the opinion poll show that energy conservation plays an important but not a dominant part in the planning of residential buildings. In the ''Landstuhl area'' energy saving investments took an above-average high position (large impact of the demonstration project). The building-owners and experts most frequently wanted and recommended increased conventional measures. It could be shown that the imagination of the building-owners was asked too much when taking measures for the use of passive solar energy.

  12. Building states without building nations: understanding urban citizenship in Dili, Timor Leste

    Directory of Open Access Journals (Sweden)

    Valenti, Alex

    2014-03-01

    Full Text Available State and nation building, although often used interchangeably in international relations policy and literature, are in fact two distinct, although closely intertwined, processes: the (recons-truction of a state cannot be reduced to a technical exercise, that is, state building; rather, it needs to focus just as significantly on the (reconstruction of the country’s social fabric in order to develop the sense of citizenship upon which its sovereignty and legitimacy rest, that is, nation building. This research note introduces urban spaces as interesting contexts to explore the relationship between state and nation building, arguing that their diversity is both a challenge and an opportunity for the state to create a sense of citizenship amongst its population. The case of Dili, the capital of Timor Leste, where a violent past and rapid urbanisation have combined to shape extremely diverse social, political and economic urban spaces, is used here to explore how the population of three case study areas perceives the impact of state policies and to question how these perceptions influence the scales at which people build their identity as well as how these scales affect the construction of local, urban or national citizenship in Timor Leste.

  13. 324 Building fire hazards analysis implementation plan

    International Nuclear Information System (INIS)

    BARILO, N.F.

    1999-01-01

    In March 1998, the 324 Building Fire Hazards Analysis (FHA) (Reference 1) was approved by the U S. Department of Energy, Richland Operations Office (DOE-RL) for implementation by B and W Hanford Company (BWHC). The purpose of the FHA was to identify gaps in compliance with DOE Order 5480.7A (Reference 2) and Richland Operations Office Implementation Directive (RLID) 5480.7 (Reference 3), especially in regard to loss limitation. The FHA identified compliance gaps in six areas and provided 20 recommendations to bring the 324 Building into compliance with DOE Order 5480 7A. Additionally, one observation was provided. A status is provided for each recommendation in this document. The actions for recommendations associated with the safety related part of the 324 Building and operation of the cells and support areas were evaluated using the Unreviewed Safety Question (USQ) process BWHC will use this Implementation Plan to bring the 324 Building and its operation into compliance with DOE Order 5480 7A and RLID 5480.7

  14. Preliminary hazard classification for Building 107-N

    International Nuclear Information System (INIS)

    Kloster, G.L.; Smith, R.L.

    1997-06-01

    Deactivation activities are planned for Building 107-N (Basin Recirculation Building). This document establishes the preliminary hazard classification (PHC) for the 100-N Area facility segment that includes this building.To establish the PHC, the inventories of radioactive and nonradioactive hazardous materials present within Building 107-N are identified and then compared to the corresponding threshold quantity values in DOE (1992) and reportable quantity values in 40 CFR 302.4. In this evaluation, no credit is taken for the form, location, and dispersibility of the materials; for their interaction with available energy sources; or for safety features that could prevent or mitigate a radioactive release. The result of this effort concluded that the PHC for Building 107-N is Nuclear Category 3

  15. Regression Tree-Based Methodology for Customizing Building Energy Benchmarks to Individual Commercial Buildings

    Science.gov (United States)

    Kaskhedikar, Apoorva Prakash

    According to the U.S. Energy Information Administration, commercial buildings represent about 40% of the United State's energy consumption of which office buildings consume a major portion. Gauging the extent to which an individual building consumes energy in excess of its peers is the first step in initiating energy efficiency improvement. Energy Benchmarking offers initial building energy performance assessment without rigorous evaluation. Energy benchmarking tools based on the Commercial Buildings Energy Consumption Survey (CBECS) database are investigated in this thesis. This study proposes a new benchmarking methodology based on decision trees, where a relationship between the energy use intensities (EUI) and building parameters (continuous and categorical) is developed for different building types. This methodology was applied to medium office and school building types contained in the CBECS database. The Random Forest technique was used to find the most influential parameters that impact building energy use intensities. Subsequently, correlations which were significant were identified between EUIs and CBECS variables. Other than floor area, some of the important variables were number of workers, location, number of PCs and main cooling equipment. The coefficient of variation was used to evaluate the effectiveness of the new model. The customization technique proposed in this thesis was compared with another benchmarking model that is widely used by building owners and designers namely, the ENERGY STAR's Portfolio Manager. This tool relies on the standard Linear Regression methods which is only able to handle continuous variables. The model proposed uses data mining technique and was found to perform slightly better than the Portfolio Manager. The broader impacts of the new benchmarking methodology proposed is that it allows for identifying important categorical variables, and then incorporating them in a local, as against a global, model framework for EUI

  16. Social acceptance of renewable energy technologies for buildings in the Helsinki Metropolitan Area of Finland

    NARCIS (Netherlands)

    Jung, N.; Moula, M.E.; Fang, T.; Hamdy, M.; Lahdelma, R.

    2016-01-01

    The application of renewable energy technologies (RETs) in the residential building sector requires acceptance of technical solutions by key stakeholders, such as building owners, real-estate developers, and energy providers. The objective of this study is to identify the current status of public

  17. Better building of valley fills

    Energy Technology Data Exchange (ETDEWEB)

    Chironis, N.P.

    1980-03-01

    Current US regulations for building valley fills or head of hollow fills to hold excess spoil resulting from contour mining are meeting with considerable opposition, particularly from operators in steep-slope areas. An alternative method has been submitted to the Office of Surface Mining by Virgina. Known as the zoned concept method, it has already been used successfully in building water-holding dams and coal refuse embankments on sloping terrain. The ways in which drainage and seepage are managed are described.

  18. 209-E Building -- Response to ventilation failure evaluation

    International Nuclear Information System (INIS)

    Foust, D.J.

    1998-01-01

    This document provides an evaluation and recommendations for radiological workplace air monitoring and response to ventilation failure for the Critical Mass Laboratory, 209-E Building. The Critical Mass Laboratory, part of the 209-E Building, was designed to provide a heavily shielded room where plutonium and uranium liquid solutions could be brought into various critical configurations under readily controlled and monitored conditions. The facility is contained within a one-story L-shaped concrete block and reinforced concrete building. One wing houses offices, a control room, shops, and a common area while the other wing includes an equipment room, the change room, work areas, and the two-story Critical Assembly Room (CAR). Three of the rooms contain radiologically contaminated equipment and materials

  19. Building Management and ICT Learning in Civil Engineering Education

    DEFF Research Database (Denmark)

    Christiansson, Per Lennart

    2005-01-01

    The paper presents structures of the learning domains of building informatics exemplified with experiences from building management civil engineering and open education in Industrial IT at Aalborg University. The courses cover areas such as; object oriented programming and relational database...... design, human computer interface, user environment design and usability engineering, computer supported collaborative working, knowledge management, virtual buildings, intelligent buildings, and building systems simulation. Experiences from many years involvement in ICT supported learning and development...... taking into account improvement of learning styles, course content and learning material is also reported....

  20. Inventory of Heritage Building in Kampung Bandar Senapelan Pekanbaru City, RIAU

    Science.gov (United States)

    Cheris, Rika; Repi

    2017-12-01

    Heritage building is a building that has a character value of local history and culture in a village and city. This heritage building is usually located in city center and into the early development of a city. In Pekanbaru, there is a group of heritage buildings with some characters. The area named Bandar Senapelan on the edge of the Siak river which has been developed before the colonization of the Netherlands.This research was conducted with field observations and interviews with local residents and then conducted measurements on the building. The data collected are compiled into a table to make it easier to conduct an inventory of the identification of the structure and construction of the building as well as the types of responses. Some of the heritage buildings in the area of Bandar Senapelan were influenced by some ethnic groups such as Minangkabau, Malay and Chinese. Those buildings have distinctive character although they do not use too many elements of architectural art, but their existence is quite able to prove past glory in the city of Pekanbaru. In this research, a core zone area was created, then the buildings’ remains were calculated. After that, the calculations and sincronization were done with a map of virtue as many as 52 heritage buildings made of wood and stone. The buildings have different tipology, as a single home (individual), the home of the fisherman, merchant's house, warehouse, shop and home stores.The output from this research will generate a mapping of the heritage buildings and it is expected that it can provide useful information for the development of the city stakeholders to determine the direction of future development of Bandar Senapelan

  1. Energy use in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-10-01

    This is the report on Task IB, Familiarization with Additional Data Collection Plans of Annual Survey of BOMA Member and Non-Member Buildings in 20 Cities, of the Energy Use in Office Buildings project. The purpose of the work was to monitor and understand the efforts of the Building Owners and Managers Association International (BOMA) in gathering an energy-use-oriented data base. In order to obtain an improved data base encompassing a broad spectrum of office space and with information suitable for energy analysis in greater detail than is currently available, BOMA undertook a major data-collection effort. Based on a consideration of geographic area, climate, population, and availability of data, BOMA selected twenty cities for data collection. BOMA listed all of the major office space - buildings in excess of 40,000 square feet - in each of the cities. Tax-assessment records, local maps, Chamber of Commerce data, recent industrial-development programs, results of related studies, and local-realtor input were used in an effort to assemble a comprehensive office-building inventory. In order to verify the accuracy and completeness of the building lists, BOMA assembled an Ad-Hoc Review Committee in each city to review the assembled inventory of space. A questionnaire on office-building energy use and building characteristics was developed. In each city BOMA assembled a data collection team operating under the supervision of its regional affiliate to gather the data. For each city a random sample of buildings was selected, and data were gathered. Responses for over 1000 buildings were obtained.

  2. Excess heat production of future net zero energy buildings within district heating areas in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    2012-01-01

    Denmark’s long-term energy goal is to develop an energy system solely based on renewable energy sources by 2050. To reach this goal, energy savings in buildings is essential. Therefore, the focus on energy efficient measures in buildings and netzeroenergybuildings (NZEBs) has increased. Most...

  3. Object-Based Dense Matching Method for Maintaining Structure Characteristics of Linear Buildings.

    Science.gov (United States)

    Su, Nan; Yan, Yiming; Qiu, Mingjie; Zhao, Chunhui; Wang, Liguo

    2018-03-29

    In this paper, we proposed a novel object-based dense matching method specially for the high-precision disparity map of building objects in urban areas, which can maintain accurate object structure characteristics. The proposed framework mainly includes three stages. Firstly, an improved edge line extraction method is proposed for the edge segments to fit closely to building outlines. Secondly, a fusion method is proposed for the outlines under the constraint of straight lines, which can maintain the building structural attribute with parallel or vertical edges, which is very useful for the dense matching method. Finally, we proposed an edge constraint and outline compensation (ECAOC) dense matching method to maintain building object structural characteristics in the disparity map. In the proposed method, the improved edge lines are used to optimize matching search scope and matching template window, and the high-precision building outlines are used to compensate the shape feature of building objects. Our method can greatly increase the matching accuracy of building objects in urban areas, especially at building edges. For the outline extraction experiments, our fusion method verifies the superiority and robustness on panchromatic images of different satellites and different resolutions. For the dense matching experiments, our ECOAC method shows great advantages for matching accuracy of building objects in urban areas compared with three other methods.

  4. Object-Based Dense Matching Method for Maintaining Structure Characteristics of Linear Buildings

    Directory of Open Access Journals (Sweden)

    Nan Su

    2018-03-01

    Full Text Available In this paper, we proposed a novel object-based dense matching method specially for the high-precision disparity map of building objects in urban areas, which can maintain accurate object structure characteristics. The proposed framework mainly includes three stages. Firstly, an improved edge line extraction method is proposed for the edge segments to fit closely to building outlines. Secondly, a fusion method is proposed for the outlines under the constraint of straight lines, which can maintain the building structural attribute with parallel or vertical edges, which is very useful for the dense matching method. Finally, we proposed an edge constraint and outline compensation (ECAOC dense matching method to maintain building object structural characteristics in the disparity map. In the proposed method, the improved edge lines are used to optimize matching search scope and matching template window, and the high-precision building outlines are used to compensate the shape feature of building objects. Our method can greatly increase the matching accuracy of building objects in urban areas, especially at building edges. For the outline extraction experiments, our fusion method verifies the superiority and robustness on panchromatic images of different satellites and different resolutions. For the dense matching experiments, our ECOAC method shows great advantages for matching accuracy of building objects in urban areas compared with three other methods.

  5. SAFETY IN THE DESIGN OF SCIENCE LABORATORIES AND BUILDING CODES.

    Science.gov (United States)

    HOROWITZ, HAROLD

    THE DESIGN OF COLLEGE AND UNIVERSITY BUILDINGS USED FOR SCIENTIFIC RESEARCH AND EDUCATION IS DISCUSSED IN TERMS OF LABORATORY SAFETY AND BUILDING CODES AND REGULATIONS. MAJOR TOPIC AREAS ARE--(1) SAFETY RELATED DESIGN FEATURES OF SCIENCE LABORATORIES, (2) LABORATORY SAFETY AND BUILDING CODES, AND (3) EVIDENCE OF UNSAFE DESIGN. EXAMPLES EMPHASIZE…

  6. High-Resolution Remote Sensing Image Building Extraction Based on Markov Model

    Science.gov (United States)

    Zhao, W.; Yan, L.; Chang, Y.; Gong, L.

    2018-04-01

    With the increase of resolution, remote sensing images have the characteristics of increased information load, increased noise, more complex feature geometry and texture information, which makes the extraction of building information more difficult. To solve this problem, this paper designs a high resolution remote sensing image building extraction method based on Markov model. This method introduces Contourlet domain map clustering and Markov model, captures and enhances the contour and texture information of high-resolution remote sensing image features in multiple directions, and further designs the spectral feature index that can characterize "pseudo-buildings" in the building area. Through the multi-scale segmentation and extraction of image features, the fine extraction from the building area to the building is realized. Experiments show that this method can restrain the noise of high-resolution remote sensing images, reduce the interference of non-target ground texture information, and remove the shadow, vegetation and other pseudo-building information, compared with the traditional pixel-level image information extraction, better performance in building extraction precision, accuracy and completeness.

  7. Investigation of thermal effect on exterior wall surface of building material at urban city area

    Energy Technology Data Exchange (ETDEWEB)

    Md Din, Mohd Fadhil; Dzinun, Hazlini; Ponraj, M.; Chelliapan, Shreeshivadasan; Noor, Zainura Zainun [Institute of Environmental Water Resources and Management (IPASA), Faculty of Civil Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor (Malaysia); Remaz, Dilshah [Faculty of Built Environment, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor (Malaysia); Iwao, Kenzo [Nagoya Institute of Technology, Nagoya (Japan)

    2012-07-01

    This paper describes the investigation of heat impact on the vertical surfaces of buildings based on their thermal behavior. The study was performed based on four building materials that is commonly used in Malaysia; brick, concrete, granite and white concrete tiles. The thermal performances on the building materials were investigated using a surface temperature sensor, data logging system and infrared thermography. Results showed that the brick had the capability to absorb and store heat greater than other materials during the investigation period. The normalized heat (total heat/solar radiation) of the brick was 0.093 and produces high heat (51% compared to granite), confirming a substantial amount of heat being released into the atmosphere through radiation and convection. The most sensitive material that absorbs and stores heat was in the following order: brick > concrete > granite > white concrete tiles. It was concluded that the type of exterior wall material used in buildings had significant impact to the environment.

  8. Radiological evaluation of building materials used in Malumfashi ...

    African Journals Online (AJOL)

    ... in building materials (sand, cement, blocks, granite, and paints) used in the construction of buildings in Malumfashi local Government area of Katsina state, Nigeria were determined by means of a gamma-ray spectrometry system using Sodium Iodide thallium activated (NaI(Tl)) detector in a low background configuration.

  9. Development of a building performance laboratory for South Africa

    CSIR Research Space (South Africa)

    Parsons, S

    2009-05-01

    Full Text Available The CSIR Building Science and Technology Competence area is currently in the process of establishing a Building Performance Laboratory (BPL). The BPL is aimed at becoming a centre at which the knowledge generation and technology development...

  10. The Japan Power Demonstration Reactor (JPDR) dismantling activities. Dismantling of the reactor enclosure and the auxiliary buildings

    International Nuclear Information System (INIS)

    Seiki, Yoshihiro; Kubo, Takashi.

    1996-01-01

    As the final stage of the JPDR decommissioning program, after the major components were removed from each building of JPDR, the dismantling activities proceeded to the decontamination of contaminated concrete surface and the final radiation survey of buildings. These activities were conducted to verify the developed techniques and the detailed procedures for decontamination, and to allow unrestricted use of the JPDR buildings. Following the decontamination of buildings, the dismantling of each building was started. Before dismantling the buildings, the radiation control designations were changed. The buildings that contaminated embedded pipes were changed from first-class radiation controlled areas to second-class radiation controlled areas. On the other hand, the buildings that had no contaminated pipes were changed to uncontrolled areas. A first-class radiation controlled area allows the use of unsealed sources ; thus, radioactive contamination may exist. A second-class radiation controlled area is one where only sealed sources are allowed. Significant quantities of data and experience were obtained during these activities. The practical procedures for decontamination, the final survey of radioactivity, and the dismantling work of buildings were described in this report. (author)

  11. Building Change Detection from Bi-Temporal Dense-Matching Point Clouds and Aerial Images.

    Science.gov (United States)

    Pang, Shiyan; Hu, Xiangyun; Cai, Zhongliang; Gong, Jinqi; Zhang, Mi

    2018-03-24

    In this work, a novel building change detection method from bi-temporal dense-matching point clouds and aerial images is proposed to address two major problems, namely, the robust acquisition of the changed objects above ground and the automatic classification of changed objects into buildings or non-buildings. For the acquisition of changed objects above ground, the change detection problem is converted into a binary classification, in which the changed area above ground is regarded as the foreground and the other area as the background. For the gridded points of each period, the graph cuts algorithm is adopted to classify the points into foreground and background, followed by the region-growing algorithm to form candidate changed building objects. A novel structural feature that was extracted from aerial images is constructed to classify the candidate changed building objects into buildings and non-buildings. The changed building objects are further classified as "newly built", "taller", "demolished", and "lower" by combining the classification and the digital surface models of two periods. Finally, three typical areas from a large dataset are used to validate the proposed method. Numerous experiments demonstrate the effectiveness of the proposed algorithm.

  12. Institutional barriers for building integrated PV

    International Nuclear Information System (INIS)

    Mierlo, B. van

    2000-01-01

    Being an alternative for fossil fuels photovoltaics have to overcome traditional structures, procedures, cultures and values. As a new building material photovoltaics also have to deal with the structure and culture of the building sector. In this paper the institutional bottlenecks for the introduction of PV on a large scale are explored in five areas: financing, administration, structure of energy sector, architecture, communication and marketing. Nevertheless, on the whole the developments are encouraging. (author)

  13. 36 CFR 702.11 - Smoking in Library buildings.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Smoking in Library buildings. 702.11 Section 702.11 Parks, Forests, and Public Property LIBRARY OF CONGRESS CONDUCT ON LIBRARY PREMISES § 702.11 Smoking in Library buildings. Smoking in Library areas is prohibited except in those...

  14. Upgrade Opportunities for Buildings in City Centres

    Directory of Open Access Journals (Sweden)

    Silva M.

    2012-10-01

    Full Text Available This proposal focus on the potential of the existing buildings upgrade process in achieving the 20-20-20 goals, as these are the biggest energy consumers, the most significant built area and the better placed buildings within our cities. These buildings frequently lack basic maintenance and need intervention, but include within themselves a vast amount of incorporated energy and centuries of construction knowledge. Beyond the advantages that may result from re-attracting people back into the city centre, upgrading these existing buildings can also have positive bounce-back effect on the reduction of the energy needs related to transportation, as demonstrated in studies that alert to the impact of the building sprawl in the total energy use. As “buildings account for 40 % of total energy consumption in the Union”, the better performance of this sector has a significant role, remembering that “these requirements shall take account of general indoor climate conditions, in order to avoid possible negative effects such as inadequate ventilation, as well as local conditions and the designated function and the age of the building” [1]. The importance of “upgrading” the existing buildings resides on the fact that new buildings represent only approximately 1 or 2% of the total usable area, an estimate that is bound to decrease due to the current construction crisis. While the recent buildings tend to be more efficient, the numerous existing buildings are important stakeholders due to their massive consumptions and incorporated energy. The ongoing Annex 56 on “Energy & Greenhouse Gas Optimized Building Renovation” assumes that “Current standards do not respond effectively to the numerous constraints imposed by existing buildings and in many cases, the requirements result in very expensive measures and complex procedures, seldom accepted by occupants, owners or developers. It is then urgent for the new standards to respond to these

  15. Aerial Imagery and LIDAR Data Fusion for Unambiguous Extraction of Adjacent Level-Buildings Footprints

    Science.gov (United States)

    Mola Ebrahimi, S.; Arefi, H.; Rasti Veis, H.

    2017-09-01

    Our paper aims to present a new approach to identify and extract building footprints using aerial images and LiDAR data. Employing an edge detector algorithm, our method first extracts the outer boundary of buildings, and then by taking advantage of Hough transform and extracting the boundary of connected buildings in a building block, it extracts building footprints located in each block. The proposed method first recognizes the predominant leading orientation of a building block using Hough transform, and then rotates the block according to the inverted complement of the dominant line's angle. Therefore the block poses horizontally. Afterwards, by use of another Hough transform, vertical lines, which might be the building boundaries of interest, are extracted and the final building footprints within a block are obtained. The proposed algorithm is implemented and tested on the urban area of Zeebruges, Belgium(IEEE Contest,2015). The areas of extracted footprints are compared to the corresponding areas in the reference data and mean error is equal to 7.43 m2. Besides, qualitative and quantitative evaluations suggest that the proposed algorithm leads to acceptable results in automated precise extraction of building footprints.

  16. A History of Building 828, Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, Rebecca

    1999-08-01

    This report documents the history of Building 828 in Sandia National Laboratories' Technical Area I. Building 828 was constructed in 1946 as a mechanical test laboratory for Los Alamos' Z-Division (later Sandia) as it moved to Sandia Base. The building has undergone significant remodeling over the years and has had a variety of occupants. The building was evaluated in compliance with the National Historic Preservation Act, but was not eligible for the National Register of Historic Places. Nevertheless, for many Labs employees, it was a symbol of Sandia's roots in World War II and the Manhattan Project.

  17. Energy requirements for new buildings in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Airaksinen, M., Email: miimu.airaksinen@vtt.fi

    2012-06-15

    Buildings account for circa 40% of the total energy use in Europe [1] and for about 36% of the EU's total CO{sub 2} emissions [2], including the existing energy conservation in buildings [3]. Key features of the Finnish energy policy are improved energy efficiency and increased use of renewable energy sources. To achieve a sustainable shift in the energy system, a target set by the authorities, both energy savings and increased use of low-pollution energy sources are therefore priority areas. Building low-energy buildings is in accordance with the declared national aim of reducing energy use and thus reducing CO{sub 2} emissions. The main motivation in renewing building codes for new buildings was to build more energy efficiently, encourage the use the most efficient energy sources and to enhance the use of renewable energy sources. In addition the aim was to give more freedom to fi nd the real optimal solutions for energy efficiency by optimising all aspects including the building architecture and different systems with demand controls. However, in order to ensure the good quality of buildings certain minimum requirements for structure U-values are given. (orig.)

  18. Classification and Filtering of Constrained Delaunay Triangulation for Automated Building Aggregation

    Directory of Open Access Journals (Sweden)

    GUO Peipei

    2016-08-01

    Full Text Available Building aggregation is an important part of research on large scale map generalization. A triangulation based approach is proposed from the perspective of shape features, six measure parameters of triangles in a constrained Delaunay triangulation are proposed. First of all, use the six measure parameters to determine which triangles are retained and which are erased. Then, the contours of retained triangles, as bridge areas between buildings, are automatically identified and right angle processed. And then, the buildings are aggregated with right angle feature retained by merging the bridge areas with connecting buildings. Finally, the approach is verified by being carried out on actual data. Experimental result shows that it is efficient and practical.

  19. Automatic Coregistration for Multiview SAR Images in Urban Areas

    Science.gov (United States)

    Xiang, Y.; Kang, W.; Wang, F.; You, H.

    2017-09-01

    Due to the high resolution property and the side-looking mechanism of SAR sensors, complex buildings structures make the registration of SAR images in urban areas becomes very hard. In order to solve the problem, an automatic and robust coregistration approach for multiview high resolution SAR images is proposed in the paper, which consists of three main modules. First, both the reference image and the sensed image are segmented into two parts, urban areas and nonurban areas. Urban areas caused by double or multiple scattering in a SAR image have a tendency to show higher local mean and local variance values compared with general homogeneous regions due to the complex structural information. Based on this criterion, building areas are extracted. After obtaining the target regions, L-shape structures are detected using the SAR phase congruency model and Hough transform. The double bounce scatterings formed by wall and ground are shown as strong L- or T-shapes, which are usually taken as the most reliable indicator for building detection. According to the assumption that buildings are rectangular and flat models, planimetric buildings are delineated using the L-shapes, then the reconstructed target areas are obtained. For the orignal areas and the reconstructed target areas, the SAR-SIFT matching algorithm is implemented. Finally, correct corresponding points are extracted by the fast sample consensus (FSC) and the transformation model is also derived. The experimental results on a pair of multiview TerraSAR images with 1-m resolution show that the proposed approach gives a robust and precise registration performance, compared with the orignal SAR-SIFT method.

  20. Building Coverage Ratio at the Eastern Corridor of Jalan Ir. H. Djuanda Bandung

    Science.gov (United States)

    Megayanti, T.; Widaningsih, L.; Minggra, R.; Dewi, N. I. K.

    2018-01-01

    Historically in the Colonial period, the Corridor of Jalan Ir. H. Juanda or better known as Jalan Dago was designed as a residential area. As the high development of commercial activity along of Bandung City, almost all of buildings in this area are turned its’ function to supported commercial activity. The change is shown in many aspects from the shape of the building and even occur in changing the old building into a new one due to a high intensity of this commercial activity. This paper investigates the use of Building Coverage Ratio regulation related to functional change in the Corridor of Jalan Ir. H. Juanda Bandung. The aim is to what extent the regulations related to Building Coverage area are implemented. This study used a descriptive qualitative method by conducting observation to identify buildings on the Corridor by dividing it into three segments. The results show quantitatively there is a lot of irrelevancies to Building Coverage Ratio regulation which is shown in the second and third segment. Most of the building in the first segment has in compliance with the regulation. However, to build a harmony in characters of City corridor is not only created by Building Coverage Ratio but also others parameters such as the land use, the shape of buildings, façade, and design concept. Thus, it is highly recommended to create a detail regulation regarding those parameters.

  1. Advantages of modern collapsible systems for exterior finishing of buildings in urban areas in Russia

    Directory of Open Access Journals (Sweden)

    Tolstova Kristina

    2017-01-01

    Full Text Available Traditionally, the method of finishing interior spaces, as well as exterior surfaces and architectural and structural elements of buildings and structures is widely used, when layers of building materials or finishing structures are applied in a strict sequence, allowing them to eventually form an unbroken whole - a “monolith”. This method of finishing, its technology and results not only depend significantly on the quality of the materials used and the mechanization of processes, but also require high qualification and specialization of construction workers. The execution of such a finish is more an art than a reproduced with a given level of quality of results by a technological process. An alternative to “monolith” is a variety of collapsible (they are also called “hinged” systems for finishing urban buildings, the elements of which are manufactured in the construction industry, requiring, as a rule, only installation and assembly in internal premises (the so-called “evroremont”, Or on the external surfaces of a building or structure.

  2. Acoustical case studies of three green buildings

    Science.gov (United States)

    Siebein, Gary; Lilkendey, Robert; Skorski, Stephen

    2005-04-01

    Case studies of 3 green buildings with LEED certifications that required extensive acoustical retrofit work to become satisfactory work environments for their intended user groups will be used to define areas where green building design concepts and acoustical design concepts require reconciliation. Case study 1 is an office and conference center for a city environmental education agency. Large open spaces intended to collect daylight through clerestory windows provided large, reverberant volumes with few acoustic finishes that rendered them unsuitable as open office space and a conference room/auditorium. Case Study 2 describes one of the first gold LEED buildings in the southeast whose primary design concepts were so narrowly focused on thermal and lighting issues that they often worked directly against basic acoustical requirements resulting in sound levels of NC 50-55 in classrooms and faculty offices, crosstalk between classrooms and poor room acoustics. Case study 3 is an environmental education and conference center with open public areas, very high ceilings, and all reflective surfaces made from wood and other environmentally friendly materials that result in excessive loudness when the building is used by the numbers of people which it was intended to serve.

  3. Radon entry into buildings: Effects of atmospheric pressure fluctuations and building structural factors

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Allen Lantham [Univ. of California, Berkeley, CA (United States). Dept. of Mechanical Engineering

    1996-05-01

    An improved understanding of the factors that control radon entry into buildings is needed in order to reduce the public health risks caused by exposure to indoor radon. This dissertation examines three issues associated with radon entry into buildings: (1) the influence of a subslab gravel layer and the size of the openings between the soil and the building interior on radon entry; (2) the effect of atmospheric pressure fluctuations on radon entry; and (3) the development and validation of mathematical models which simulate radon and soil-gas entry into houses. Experiments were conducted using two experimental basements to examine the influence of a subslab gravel layer on advective radon entry driven by steady indoor-outdoor pressure differences. These basement structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The measurements indicate that a high permeability subslab gravel layer increases the advective radon entry rate into the structure by as much as a factor of 30. The magnitude of the enhancement caused by the subslab gravel layer depends on the area of the openings in the structure floor; the smaller the area of these openings the larger the enhancement in the radon entry rate caused by the subslab gravel layer. A three-dimensional, finite-difference model correctly predicts the effect of a subslab gravel layer and open area configuration on advective radon entry driven by steady indoor-outdoor pressure differences; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5.

  4. Radon entry into buildings: Effects of atmospheric pressure fluctuations and building structural factors

    International Nuclear Information System (INIS)

    Robinson, A.L.

    1996-05-01

    An improved understanding of the factors that control radon entry into buildings is needed in order to reduce the public health risks caused by exposure to indoor radon. This dissertation examines three issues associated with radon entry into buildings: (1) the influence of a subslab gravel layer and the size of the openings between the soil and the building interior on radon entry; (2) the effect of atmospheric pressure fluctuations on radon entry; and (3) the development and validation of mathematical models which simulate radon and soil-gas entry into houses. Experiments were conducted using two experimental basements to examine the influence of a subslab gravel layer on advective radon entry driven by steady indoor-outdoor pressure differences. These basement structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The measurements indicate that a high permeability subslab gravel layer increases the advective radon entry rate into the structure by as much as a factor of 30. The magnitude of the enhancement caused by the subslab gravel layer depends on the area of the openings in the structure floor; the smaller the area of these openings the larger the enhancement in the radon entry rate caused by the subslab gravel layer. A three-dimensional, finite-difference model correctly predicts the effect of a subslab gravel layer and open area configuration on advective radon entry driven by steady indoor-outdoor pressure differences; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5

  5. Architecture and pervasive Computing when buildings and design artifacts become popular interfaces

    DEFF Research Database (Denmark)

    Krogh, Peter Gall; Grønbæk, Kaj

    2001-01-01

    One of the main areas of architecture is buildings design, and we will focus on the impact of pervasive computing in this area. The breakthrough of the Internet has triggered a significant increase in what is often called intelligent buildings 1  in recent years. Due to development in pervasive c...

  6. Monitoring the Energy-Use Effects of Cool Roofs on California Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Konopaki, Steve; Rainer, Leo

    2004-07-01

    Solar-reflective roofs stay cooler in the sun than solar-absorptive roofs. Such ''cool'' roofs achieve lower surface temperatures that reduce heat conduction into the building and the building's cooling load. The California Energy Commission has funded research in which Lawrence Berkeley National Laboratory (LBNL) has measured the electricity use and peak demand in commercial buildings to document savings from implementing the Commission's Cool Roofs program. The study seeks to determine the savings achieved by cool roofs by monitoring the energy use of a carefully selected assortment of buildings participating in the Cool Roofs program. Measurements were needed because the peak savings resulting from the application of cool roofs on different types of buildings in the diverse California climate zones have not been well characterized to date. Only a few occupancy categories (e.g., office and retail buildings) have been monitored before this, and those were done under a limited number of climatic conditions. To help rectify this situation, LBNL was tasked to select the buildings to be monitored, measure roof performance before and after replacing a hot roof by a cool roof, and document both energy and peak demand savings resulting from installation of cool roofs. We monitored the effects of cool roofs on energy use and environmental parameters in six California buildings at three different sites: a retail store in Sacramento; an elementary school in San Marcos (near San Diego); and a 4-building cold storage facility in Reedley (near Fresno). The latter included a cold storage building, a conditioning and fruit-palletizing area, a conditioned packing area, and two unconditioned packing areas (counted as one building).

  7. Comparative study of building footprint estimation methods from LiDAR point clouds

    Science.gov (United States)

    Rozas, E.; Rivera, F. F.; Cabaleiro, J. C.; Pena, T. F.; Vilariño, D. L.

    2017-10-01

    Building area calculation from LiDAR points is still a difficult task with no clear solution. Their different characteristics, such as shape or size, have made the process too complex to automate. However, several algorithms and techniques have been used in order to obtain an approximated hull. 3D-building reconstruction or urban planning are examples of important applications that benefit of accurate building footprint estimations. In this paper, we have carried out a study of accuracy in the estimation of the footprint of buildings from LiDAR points. The analysis focuses on the processing steps following the object recognition and classification, assuming that labeling of building points have been previously performed. Then, we perform an in-depth analysis of the influence of the point density over the accuracy of the building area estimation. In addition, a set of buildings with different size and shape were manually classified, in such a way that they can be used as benchmark.

  8. Analysis and proposal of implementation effects of heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China in “the 11th Five-Year Plan” period

    International Nuclear Information System (INIS)

    Bao Lingling; Zhao Jing; Zhu Neng

    2012-01-01

    In China, northern heating region contains approximately 6.5 billion m 2 residential building areas accounting for 15% of the total residential living areas of urban and rural. About 70% of the urban residential buildings in north China are high energy consumption buildings. The task of heat metering and energy efficiency retrofit of 0.15 billion m 2 existing residential buildings in northern heating areas of China in “the 11th Five-Year Plan” period was proposed by the Ministry of Housing and Urban–Rural Development (MOHURD) in 2007 and completed in 2010. This paper introduced both central and local governments' efforts on organization, implementation and finance, etc. Then several retrofitting effects involving improving the people's livelihood, mobilizing the enthusiasm of residents for the retrofit and driving the development of relevant industries were presented. Finally, on the basis of analyzing the issues encountered in the progress of the retrofit in the past 4 years, the paper gave some policy proposals on organization system, financing models, reward mechanism, and heating system reformation to help to promote the energy efficiency retrofit in “the 12th Five-Year Plan” period. - Highlights: ► Specific approaches of heat metering and energy efficiency retrofit (HMEER) at central and local level are introduced. ► Main HMEER effects are presented. ► Analyzing several issues encountered in the progress of the HMEER. ► Corresponding proposals are provided.

  9. Differential pressures on building walls during tornados

    International Nuclear Information System (INIS)

    Yeh, G.C.K.

    1975-01-01

    In the United States, containment structures and some auxiliary structures (control building, auxiliary building, spent fuel building, etc.) in nuclear power plants are required to be designed to withstand the effects of the design basis tornado. In addition to velocity pressures and missile impact a tornado also gives rise to a rapid change in atmospheric pressure, which can, in cases of closed or partially vented structures, produce direct differential pressure loading. In this paper a digital computer program is described which applies a tornado-induced, time-dependent atmospheric pressure change to a building and calculates the differential pressure histories across the interior and exterior walls of the building. Laws for quasi-steady, one-dimensional motion of an ideal compressible gas are used to calculate the pressures due to the flow of air through ports, doors and windows in the building. Numerical examples show that for each assumed atmospheric pressure change history a vent area to compartment volume ratio may be specified as the criterion for a building to be considered fully vented. (orig.) [de

  10. Building systems. Applications - technologies - demands; Vernetzte Gebaeudesysteme. Anwendungen - Technologien - Forderungen

    Energy Technology Data Exchange (ETDEWEB)

    Moehl, U. [JOHNSON CONTROLS JCI Regelungstechnik GmbH, Essen (Germany)

    2003-09-01

    The dream of the 'Smart Home' or 'Intelligent Building' seems to become reality. Building users can operate their building systems from anywhere inside and outside the building based upon proven technologies. Service providers have the opportunity to take partial or full responsibility for building systems, facility management and even care taking in an effective way. Besides all the success, there are still many hurdles that need to be managed during planning, installation and operation. This paper provides inside information on above-mentioned subject and possible areas of concern. (orig.)

  11. AUTOMATIC BUILDING OUTLINING FROM MULTI-VIEW OBLIQUE IMAGES

    Directory of Open Access Journals (Sweden)

    J. Xiao

    2012-07-01

    Full Text Available Automatic building detection plays an important role in many applications. Multiple overlapped airborne images as well as lidar point clouds are among the most popular data sources used for this purpose. Multi-view overlapped oblique images bear both height and colour information, and additionally we explicitly have access to the vertical extent of objects, therefore we explore the usability of this data source solely to detect and outline buildings in this paper. The outline can then be used for further 3D modelling. In the previous work, building hypotheses are generated using a box model based on detected façades from four directions. In each viewing direction, façade edges extracted from images and height information by stereo matching from an image pair is used for the façade detection. Given that many façades were missing due to occlusion or lack of texture whilst building roofs can be viewed in most images, this work mainly focuses on improve the building box outline by adding roof information. Stereo matched point cloud generated from oblique images are combined with the features from images. Initial roof patches are located in the point cloud. Then AdaBoost is used to integrate geometric and radiometric attributes extracted from oblique image on grid pixel level with the aim to refine the roof area. Generalized contours of the roof pixels are taken as building outlines. The preliminary test has been done by training with five buildings and testing around sixty building clusters. The proposed method performs well concerning covering the irregular roofs as well as improve the sides location of slope roof buildings. Outline result comparing with cadastral map shows almost all above 70% completeness and correctness in an area-based assessment, as well as 20% to 40% improvement in correctness with respect to our previous work.

  12. Building Design Guidelines for Solar Energy Technologies

    Science.gov (United States)

    Givoni, B.

    1989-01-01

    There are two main objectives to this publication. The first is to find out the communalities in the experience gained in previous studies and in actual applications of solar technologies in buildings, residential as well as nonresidential. The second objective is to review innovative concepts and products which may have an impact on future developments and applications of solar technologies in buildings. The available information and common lessons were collated and presented in a form which, hopefully, is useful for architects and solar engineers, as well as for teachers of "solar architecture" and students in Architectural Schools. The publication is based mainly on the collection and analysis of relevant information. The information included previous studies in which the performance of solar buildings was evaluated, as well as the personal experience of the Author and the research consultants. The state of the art, as indicated by these studies and personal experience, was summarized and has served as basis for the development of the Design Guidelines. In addition to the summary of the state of the art, as was already applied in solar buildings, an account was given of innovative concepts and products. Such innovations have occurred in the areas of thermal storage by Phase Change Materials (PCM) and in glazing with specialized or changeable properties. Interesting concepts were also developed for light transfer, which may enable to transfer sunlight to the core areas of large multi story nonresidential buildings. These innovations may have a significant impact on future developments of solar technologies and their applications in buildings.

  13. Energy-efficient building - Deficits in higher education

    International Nuclear Information System (INIS)

    Lang, T.; Messmer, R.; Kunz, M.

    2005-01-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the courses of study offered by Swiss Universities of Applied Science and the Federal Institutes of Technology that are concerned with the use of energy in the building area. The results of the survey are presented and commented on. The authors are of the opinion that basic courses of study fulfil their task of knowledge-transfer in the areas concerning energy, ecology, environment and sustainability, although the educational structures used are complex. The importance of interdisciplinary work is stressed. The focus of knowledge-transfer on persons under 40 years of age is criticised as well as deficits in interdisciplinary teamwork. The authors recommend the setting-up of further education programmes for older architects and professionals in the building technical services area

  14. Designing of zero energy office buildings in hot arid climate

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Gwad, Mohamed

    2011-07-01

    The designing of office buildings by using large glass areas to have a transparent building is an attractive approach in the modern office building architecture. This attitude increases the energy demand for cooling specially in the hot arid region which has long sun duration time, while the use of small glazing areas increases the energy demand for lighting. The use of uncontrolled natural ventilation increases the rate of hot ambient air flow which increases the building energy demand for cooling. At the same time, the use of mechanical ventilation to control the air change rate may increase the energy demand for fans. Some ideas such as low energy design concept are introduced for improving the building energy performance and different rating systems have been developed such as LEED, BREEAM and DGNB for evaluating building energy performance system. One of the new ideas for decreasing the dependence on fossil fuels and improving the use of renewable energy is the net zero-energy building concept in which the building generates enough renewable energy on site to equal or exceed its annual energy use. This work depends on using the potentials of mixing different energy strategies such as hybrid ventilation strategy, passive night cooling, passive chilled ceiling side by side with the integrating of photovoltaic modules into the building facade to produce energy and enrich the architectural aesthetics and finally reaching the Net Zero Energy Building. There are different definitions for zero energy buildings, however in this work the use of building-integrated Photovoltaic (BIPV) to provide the building with its annual energy needs is adopted, in order to reach to a Grid-Connected Net-Zero Energy Office Building in the hot arid desert zone represented by Cairo, Egypt. (orig.)

  15. Cultural Resource Survey Report. Hildebrand Ranch Area: Proposed Chatfield Arboretum.

    Science.gov (United States)

    1981-05-01

    stabilization and attic re- pair General Purpose Shed X X Chicken Coop X X Carriage Shed X x Corrals and Fences X X Grape Arbor x Inventory of Buildings and Fact...area of about 350 acres and included the en- tire ranch except for the areas of ground occupied by buildings and parking lots. The area along Deer

  16. The value of building plots in Italy - pdf

    Directory of Open Access Journals (Sweden)

    Paolo Rosato

    2014-12-01

    Full Text Available This paper suggests some analysis on dynamics of building plots value in Italy. This is an important subject, since the study of changes in plots value in space and time enables the evaluation of urban rent, which is essential for a fair and effective planning. The analysis confirm past hypothesis which are well known to real estate market operators. The first resulting fact is that the changes in building plots value are concurrent to those in real estate value and the increase occurring in the last years is in relative terms higher than the past one. This seems to confirm that, during real estate market expansion, most of the increase of buildings’ value is attributable to the land rent. The second observation is about value dynamics over time: it has been observed that, during an expansion in demand, the value significantly increases in central areas, much more than in peripheral ones; this means that absolute rent arising from shortage in urban areas is higher than the differential rent created through urban expansion in peripheral areas. Finally, it was highlighted that the factors affecting the value in building areas play different roles, depending on their location relative to the urban centre, identifying differently structured market segments.

  17. A building characterization-based method for the advancement of knowledge on external architectural features of traditional rural buildings

    Directory of Open Access Journals (Sweden)

    Porto, S. M. C.

    2013-12-01

    Full Text Available The significant role that traditional rural buildings have with regard to environmental conservation and rural development is widely acknowledged by the scientific community. These buildings must be protected from inappropriate building interventions that may stem from their rather superficial knowledge. Therefore, this study was directed towards overcoming such a limitation by developing a method based on traditional rural buildings’ characterization. In particular, the study aimed at the characterization of building materials and techniques used for the construction of a number of building components that make up the external envelope of traditional rural buildings. The application of the method to a homogeneous area of the Etna Regional Park (Italy highlighted the need to improve the technical norms of the park’s Territorial Coordination Plan to respect the building characteristics of the traditional rural buildings located in the protected area.La comunidad científica le atribuye a las construcciones rurales tradicionales un papel fundamental en términos de conservación del medioambiente y de evolución rural. Dichos edificios deben ser protegidos contra obras inapropiadas debidas a un conocimiento más bien superficial. Por lo tanto, el objetivo de este estudio fue el de eliminar dichas limitaciones desarrollando un método basado en la caracterización de las construcciones rurales tradicionales, que puede ser aplicado para mejorar el conocimiento de estas últimas. En particular, el susodicho estudio tiene la finalidad de caracterizar los materiales y las técnicas constructivas a emplear para la construcción de algunos componentes del envoltorio externo de las construcciones rurales tradicionales. La aplicación del método propuesto a una zona homogénea del Parque Regional del Etna (Italia puso de relieve la necesidad de mejorar las normas técnicas del Plan de Coordinación Territorial del parque para respetar las caracter

  18. The energy investment decision in the nonresidential building sector: Research into the areas of influence

    Energy Technology Data Exchange (ETDEWEB)

    Harkreader, S.A.; Ivey, D.L.

    1987-04-01

    The purpose of this report is to describe and to characterize the decision process in the nonresidential building sector as well as the variables influencing energy investment decisions, both of which impact the development of R and D agendas for the Office of Building and Community Systems (BCS). The report reviews the available information on the factors that influence energy investment decisions and identifies information gaps where additional research is needed. This report focuses on variables and combinations of these variables (descriptive states) that influence the non residential energy investment decision maker. Economic and demographic descriptors, energy investment decision maker characteristics, and variables affecting energy investments are identified. This response examines the physical characteristics of buildings, characteristics of the legal environment surrounding buildings, demographic factors, economic factors, and decision processes, all of which impact the nonresidential energy investment market. The emphasis of the report is on providing possible methodologies for projecting the future of the nonresidential energy investment market, as well as, collecting the data necessary for such projections. The use of alternate scenarios is suggested as a projection tool and suggestions for collecting the appropriate data are made in the recommendations.

  19. AUTOMATIC COREGISTRATION FOR MULTIVIEW SAR IMAGES IN URBAN AREAS

    Directory of Open Access Journals (Sweden)

    Y. Xiang

    2017-09-01

    Full Text Available Due to the high resolution property and the side-looking mechanism of SAR sensors, complex buildings structures make the registration of SAR images in urban areas becomes very hard. In order to solve the problem, an automatic and robust coregistration approach for multiview high resolution SAR images is proposed in the paper, which consists of three main modules. First, both the reference image and the sensed image are segmented into two parts, urban areas and nonurban areas. Urban areas caused by double or multiple scattering in a SAR image have a tendency to show higher local mean and local variance values compared with general homogeneous regions due to the complex structural information. Based on this criterion, building areas are extracted. After obtaining the target regions, L-shape structures are detected using the SAR phase congruency model and Hough transform. The double bounce scatterings formed by wall and ground are shown as strong L- or T-shapes, which are usually taken as the most reliable indicator for building detection. According to the assumption that buildings are rectangular and flat models, planimetric buildings are delineated using the L-shapes, then the reconstructed target areas are obtained. For the orignal areas and the reconstructed target areas, the SAR-SIFT matching algorithm is implemented. Finally, correct corresponding points are extracted by the fast sample consensus (FSC and the transformation model is also derived. The experimental results on a pair of multiview TerraSAR images with 1-m resolution show that the proposed approach gives a robust and precise registration performance, compared with the orignal SAR-SIFT method.

  20. Three-Dimensional Reconstruction and Solar Energy Potential Estimation of Buildings

    Science.gov (United States)

    Chen, Y.; Li, M.; Cheng, L.; Xu, H.; Li, S.; Liu, X.

    2017-12-01

    In the context of the construction of low-carbon cities, green cities and eco-cities, the ability of the airborne and mobile LiDAR should be explored in urban renewable energy research. As the main landscape in urban environment, buildings have large regular envelopes could receive a huge amount of solar radiation. In this study, a relatively complete calculation scheme about building roof and façade solar utilization potential is proposed, using building three-dimensional geometric feature information. For measuring the city-level building solar irradiance, the precise three-dimensional building roof and façade models should be first reconstructed from the airborne and mobile LiDAR, respectively. In order to obtaining the precise geometric structure of building facades from the mobile LiDAR data, a new method for structure detection and the three-dimensional reconstruction of building façades from mobile LiDAR data is proposed. The method consists of three steps: the preprocessing of façade points, the detection of façade structure, the restoration and reconstruction of building façade. As a result, the reconstruction method can effectively deal with missing areas caused by occlusion, viewpoint limitation, and uneven point density, as well as realizing the highly complete 3D reconstruction of a building façade. Furthermore, the window areas can be excluded for more accurate estimation of solar utilization potential. After then, the solar energy utilization potential of global building roofs and facades is estimate by using the solar irradiance model, which combine the analysis of the building shade and sky diffuse, based on the analysis of the geometrical structure of buildings.

  1. Effects of different building blocks designs on the statistical ...

    African Journals Online (AJOL)

    Tholang T. Mokhele

    Enumeration Areas (EAs), Small Area Layers (SALs) and SubPlaces) from the 2001 census data were used as building blocks for the generation of census output areas with AZTool program in both rural and urban areas of South Africa. One way-Analysis of Variance (ANOVA) was also performed to determine statistical ...

  2. Balancing Hydronic Systems in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Ruch, Russell [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Ludwig, Peter [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Maurer, Tessa [Partnership for Advanced Residential Retrofit, Chicago, IL (United States)

    2014-07-01

    In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution, and controls. The imbalance leads to tenant discomfort, higher energy use intensity, and inefficient building operation. This research, conducted by Building America team Partnership for Advanced Residential Retrofit, explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61°F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1°F to 15.5°F.

  3. Thermographic survey of two rural buildings in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Martin Ocana, S.; Canas Guerrero, I. [Departamento de Construccion y Vias Rurales, Escuela Tecnica Superior de Ingenieros Agronomos, Universidad Politecnica de Madrid, Madrid (Spain); Gonzalez Requena, I. [Departamento de Materiales y Produccion Aeroespacial, Escuela Tecnica Superior de Ingenieros Aeronauticos, Universidad Politecnica de Madrid, Madrid (Spain)

    2004-07-01

    Two common housing prototypes of existing buildings in Spanish rural areas were surveyed by infrared inspection. The aim of the study is to assess the usefulness of infrared thermography as a technique for the detection of the thermal performance of rural buildings. For the traditional house the best results were obtained in the thermographic survey carried out in the evening. Contrarily, for the modern house the thermographic survey at daybreak provided more information. Infrared thermography allowed the comparison of the thermal performance of two buildings. (author)

  4. RIVER CORRIDOR BUILDINGS 324 and 327 CLEANUP

    International Nuclear Information System (INIS)

    BAZZELL, K.D.; SMITH, B.A.

    2006-01-01

    A major challenge in the recently awarded River Corridor Closure (RCC) Contract at the U.S. Department of Energy's (DOE) Hanford Site is decontaminating and demolishing (D and D) facilities in the 300 Area. Located along the banks of the Columbia River about one mile north of Richland, Washington, the 2.5 km 2 (1 mi 2 )300 Area comprises only a small part of the 1517 km 2 (586 mi 2 ) Hanford Site. However, with more than 300 facilities ranging from clean to highly contaminated, D and D of those facilities represents a major challenge for Washington Closure Hanford (WCH), which manages the new RCC Project for DOE's Richland Operations Office (RL). A complicating factor for this work is the continued use of nearly a dozen facilities by the DOE's Pacific Northwest National Laboratory (PNNL). Most of the buildings will not be released to WCH until at least 2009--four years into the seven-year, $1.9 billion RCC Contract. The challenge will be to deactivate, decommission, decontaminate and demolish (D4) highly contaminated buildings, such as 324 and 327, without interrupting PNNL's operations in adjacent facilities. This paper focuses on the challenges associated with the D4 of the 324 Building and the 327 Building

  5. Building and strengthening confidence and security in Asia

    International Nuclear Information System (INIS)

    Corden, P.S.

    1992-01-01

    This paper presents a few thoughts on the question of building and strengthening confidence and security in Asia, in particular in the area centred on the Korean peninsula. This question includes the process of establishing and implementing confidence- and security-building measures, some of which might involve States other than North and South Korea. The development of CSBMs has now been well established in Europe, and there are encouraging signs that such measures are taking hold in other areas of the world, including in Korea. Consequently there is a fairly rich mine of information, precedent and experience from which to draw in focusing on the particular subject at hand. In these remarks the concept of confidence- and security-building is briefly addressed and measures are examined that have proven useful in other circumstances and review some possibilities that appear of interest in the present context

  6. WASTE TREATMENT BUILDING SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    F. Habashi

    2000-06-22

    The Waste Treatment Building System provides the space, layout, structures, and embedded subsystems that support the processing of low-level liquid and solid radioactive waste generated within the Monitored Geologic Repository (MGR). The activities conducted in the Waste Treatment Building include sorting, volume reduction, and packaging of dry waste, and collecting, processing, solidification, and packaging of liquid waste. The Waste Treatment Building System is located on the surface within the protected area of the MGR. The Waste Treatment Building System helps maintain a suitable environment for the waste processing and protects the systems within the Waste Treatment Building (WTB) from most of the natural and induced environments. The WTB also confines contaminants and provides radiological protection to personnel. In addition to the waste processing operations, the Waste Treatment Building System provides space and layout for staging of packaged waste for shipment, industrial and radiological safety systems, control and monitoring of operations, safeguards and security systems, and fire protection, ventilation and utilities systems. The Waste Treatment Building System also provides the required space and layout for maintenance activities, tool storage, and administrative facilities. The Waste Treatment Building System integrates waste processing systems within its protective structure to support the throughput rates established for the MGR. The Waste Treatment Building System also provides shielding, layout, and other design features to help limit personnel radiation exposures to levels which are as low as is reasonably achievable (ALARA). The Waste Treatment Building System interfaces with the Site Generated Radiological Waste Handling System, and with other MGR systems that support the waste processing operations. The Waste Treatment Building System interfaces with the General Site Transportation System, Site Communications System, Site Water System, MGR

  7. WASTE TREATMENT BUILDING SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    Habashi, F.

    2000-01-01

    The Waste Treatment Building System provides the space, layout, structures, and embedded subsystems that support the processing of low-level liquid and solid radioactive waste generated within the Monitored Geologic Repository (MGR). The activities conducted in the Waste Treatment Building include sorting, volume reduction, and packaging of dry waste, and collecting, processing, solidification, and packaging of liquid waste. The Waste Treatment Building System is located on the surface within the protected area of the MGR. The Waste Treatment Building System helps maintain a suitable environment for the waste processing and protects the systems within the Waste Treatment Building (WTB) from most of the natural and induced environments. The WTB also confines contaminants and provides radiological protection to personnel. In addition to the waste processing operations, the Waste Treatment Building System provides space and layout for staging of packaged waste for shipment, industrial and radiological safety systems, control and monitoring of operations, safeguards and security systems, and fire protection, ventilation and utilities systems. The Waste Treatment Building System also provides the required space and layout for maintenance activities, tool storage, and administrative facilities. The Waste Treatment Building System integrates waste processing systems within its protective structure to support the throughput rates established for the MGR. The Waste Treatment Building System also provides shielding, layout, and other design features to help limit personnel radiation exposures to levels which are as low as is reasonably achievable (ALARA). The Waste Treatment Building System interfaces with the Site Generated Radiological Waste Handling System, and with other MGR systems that support the waste processing operations. The Waste Treatment Building System interfaces with the General Site Transportation System, Site Communications System, Site Water System, MGR

  8. Overview of rural building energy efficiency in China

    International Nuclear Information System (INIS)

    He, Bao-jie; Yang, Li; Ye, Miao; Mou, Ben; Zhou, Yanan

    2014-01-01

    Over the past three decades, people's living standard in China has been greatly improved, accompanied by the rapid increasing building energy consumption. Rural building energy consumption has become one of the most important parts of the total energy consumption in China, which deserves to be paid much attention. It is of vital importance to promote building energy efficiency for the New Socialist Countryside and energy conservation and emission reduction. This paper provides an overview of building energy consumption in the countryside, which figures out the situation and challenges in energy-saving work. The government has worked for years on rural building code system aimed at narrowing the energy gap between urban areas, but it is in the beginning phase. This paper has analyzed the only special issues about rural building energy efficiency and the mandatory standards for urban buildings, which can facilitate the development of rural building energy efficiency. Based on the above analysis, some recommendations regarding the improvement of rural building energy efficiency are given. - Highlights: • Situation of rural energy consumption in China. • Challenges in rural building energy-saving work. • Design standard, special plan and some pilot projects are analyzed. • Effects of existing energy policies for urban buildings. • Some recommendations are given

  9. Sustainable industrial estate by managing the building coverage ratio in Cibitung Industrial Town, Indonesia

    Science.gov (United States)

    Budiyanto, T. M. T.; Prajitno, I. S.; Hasibuan, H. S.

    2018-03-01

    The problem faced in the management of the industrial estate is the development of industrial buildings which are not in accordance with the existing environmental regulations, especially the building coverage ratio (BCR). This violation is due to the limitation of industrial land owned, and the tenant’s desire to maximize building area. This research conducted at Cibitung Industrial Town, Indonesia, to assess the compliance of industrial building in complying with environmental regulations, and efforts by industrial estate manager together with industrial communities to meet building regulations. The compliance is shown from the conformity of the tenant’s BCR to the building provisions contained in the regulation within the industrial estate; which is maximum 60% from land owned. And whether the rest of green open space (GOS) area can still be maintained at a minimum 10%. This study found tenant’s building density (BCR) at 24.55% population was 84.77%, and the rest of green open space at 21.56% population was only 2.49%. Excessive building development and expansion by the industrial communities, led to a continued reduction in green open space as a rainwater absorption area. It is resulting the rainfall runoff directly into the environmental drainage system, and causing flooding in the region.

  10. Build, renovate and invest economically - Efficiency and economic viability in harmony

    International Nuclear Information System (INIS)

    Meier, R.; Beck, M.; Previdoli, P.

    2002-01-01

    This book presents 13 papers that provide the latest know-how on energy economics in the building area. The authors show the importance of information and knowledge transfer when using new energy technologies. The topics covered include the role of the Swiss research programme on energy economy fundamentals, indicator systems for sustainability factors and energy characteristics of buildings. Also a discussion of the question 'rebuild or renovate', as well a series of articles about low-flow mechanical ventilation and the marketing of low-energy consumption building concepts are presented. Further articles cover the marketing of thermal solar systems as well as technology dissemination and monitoring. Also, the marginal costs of energy efficiency measures and the potential for energy savings and environmental management in trade and industry are discussed. Finally, two papers deal with the application of Swiss SIA building standards as well as technical developments and energy efficiency in the building and renovation areas

  11. Building Contour Extraction Based on LiDAR Point Cloud

    Directory of Open Access Journals (Sweden)

    Zhang Xu-Qing

    2017-01-01

    Full Text Available This paper presents a new method for solving the problem of utilizing the LiDAR data to extract the building contour line. For detection of the edge points between the building test points by using the least squares fitting to get the edge line of buildings and give the weight determining of the building of edge line slope depend on the length of the edge line. And then get the weighted mean of the positive and negative slope of the building edge line. Based on the structure of the adjacent edge perpendicular hypothesis, regularization processing to extract the edge of the skeleton line perpendicular. The experiments show that the extracted building edges have the good accuracy and have the good applicability in complex urban areas.

  12. STRENGTHENING OF TRENCH COVER PLATES FOR SWITCHGEAR BUILDING

    International Nuclear Information System (INIS)

    M.S. RUBEN

    2000-01-01

    The objective of this calculation is to strengthen the existing trench cover plates of the Electrical Switchgear Building (BLDG 5010) of the Exploratory Studies Facility. A remodeling effort will change the portion of the facility that has the trenches for electrical cables to a craft/shop area. The users of the building will be using a forklift in this area (Clark CGP 30 forklift with a capacity of 3 tons). The trench covers require strengthening to support the wheel loads from the forklift. The output of this calculation will be sketches revising the floor plate details of DWG YMP-025-1-7007-ST103,2. (Details 4 and 5)

  13. Impact of tall buildings in environmental pollution

    Directory of Open Access Journals (Sweden)

    H. Hayati

    2012-03-01

    Full Text Available Today, tall building is a phenomenon that the world particularly large cities are facing. The tall buildings in order to exploit the land with having the negative affects in the environment create new problems including increasing congestion population, environmental pollution, reduce citizen access to fresh air and sunlight. However, regarding to population increasing and land shortage, tall buildings could not be avoided. This paper investigates the relationship of tall buildings with urban air pollution as well as the possible reducing of negative affects of tall building on environmental pollution with respect to geographical position, technicalrules, immunization, green space, direct of wind, appropriate distance to other buildings, design in terms of visibility and landscape and urban appearance were reviewed. The study showed that the tall buildings cause increasing the air pollution in large urban area due to changing in wind and its direction and also congestion of tall buildings as a pollution sources. Therefore some techniques to design the tall building must be considered to reduce the negative affects of the tall buildings on environmental pollution. Unfortunately the lack of the construction roles in term of environmental protection and also control of the rules in construction process causing the environmental pollution particularly air pollution. It is suggested that the re-evaluate of the rules with restricted control can improve the air quality in the large cities and also utilization of green spaces in floors and roofs of buildings as environmentally friendly buildings which are attempt to reduce environmental problems.

  14. Geophysics: Building E5481 decommissioning, Aberdeen Proving Ground

    International Nuclear Information System (INIS)

    Thompson, M.D.; McGinnis, M.G.; McGinnis, L.D.; Miller, S.F.

    1992-11-01

    Building E5481 is one of ten potentially contaminated sites in the Canal Creek and Westwood areas of the Edgewood section of Aberdeen Proving Ground examined by a geophysical team from Argonne National Laboratory in April and May of 1992. Noninvasive geophysical surveys, including magnetics, electrical resistivity, and ground-penetrating radar, were conducted around the perimeter of the building to guide a sampling program prior to decommissioning and dismantling. The building is located on the northern margin of a landfill that was sited in a wetland. The large number of magnetic sources surrounding the building are believed to be contained in construction fill that had been used to raise the grade. The smaller anomalies, for the most part, are not imaged with ground radar or by electrical profiling. A conductive zone trending northwest to southeast across the site is spatially related to an old roadbed. Higher resistivity areas in the northeast and east are probably representive of background values. Three high-amplitude, positive, rectangular magnetic anomalies have unknown sources. The features do not have equivalent electrical signatures, nor are they seen with radar imaging

  15. 30 CFR 77.508-1 - Lightning arresters; wires entering buildings.

    Science.gov (United States)

    2010-07-01

    .... 77.508-1 Section 77.508-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS... buildings. Lightning arresters protecting exposed telephone wires entering buildings shall be provided at...

  16. BLAST: Building energy simulation in Hong Kong

    Science.gov (United States)

    Fong, Sai-Keung

    1999-11-01

    The characteristics of energy use in buildings under local weather conditions were studied and evaluated using the energy simulation program BLAST-3.0. The parameters used in the energy simulation for the study and evaluation include the architectural features, different internal building heat load settings and weather data. In this study, mathematical equations and the associated coefficients useful to the industry were established. A technology for estimating energy use in buildings under local weather conditions was developed by using the results of this study. A weather data file of Typical Meteorological Years (TMY) has been compiled for building energy studies by analyzing and evaluating the weather of Hong Kong from the year 1979 to 1988. The weather data file TMY and the example weather years 1980 and 1988 were used by BLAST-3.0 to evaluate and study the energy use in different buildings. BLAST-3.0 was compared with other building energy simulation and approximation methods: Bin method and Degree Days method. Energy use in rectangular compartments of different volumes varying from 4,000 m3 to 40,000 m3 with different aspect ratios were analyzed. The use of energy in buildings with concrete roofs was compared with those with glass roofs at indoor temperature 21°C, 23°C and 25°C. Correlation relationships among building energy, space volume, monthly mean temperature and solar radiation were derived and investigated. The effects of space volume, monthly mean temperature and solar radiation on building energy were evaluated. The coefficients of the mathematical relationships between space volume and energy use in a building were computed and found satisfactory. The calculated coefficients can be used for quick estimation of energy use in buildings under similar situations. To study energy use in buildings, the cooling load per floor area against room volume was investigated. The case of an air-conditioned single compartment with 5 m ceiling height was

  17. Balancing Hydronic Systems in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Ruch, R.; Ludwig, P.; Maurer, T.

    2014-07-01

    In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

  18. Control of high natural activity building materials and land areas in the Nordic countries

    International Nuclear Information System (INIS)

    Mjoenes, L.

    1997-01-01

    Enhanced levels of natural radioactivity in the ground can cause problems with high concentrations of indoor 222 Rn, elevated levels of gamma radiation and natural radioactive elements in drinking water. Of the Nordic countries it is essentially Finland, Norway and Sweden that have problems with enhanced natural radioactivity in the ground and in building materials. Finland and Sweden have among the highest mean 222 Rn concentrations in dwellings in the world, 123 Bq m -3 and 108 Bq m -3 with a corresponding mean annual effective dose of about 2 mSv. In Sweden about 500,000 and in Finland and Norway about 200,000 persons get their drinking water from wells drilled in bedrock. The water from a large number of these wells contain elevated levels of naturally occurring radioactive elements, primarily 222 Rn. The action levels for 222 Rn in dwellings and above-ground workplaces are essentially the same in Finland, Norway and Sweden: 200 Bq m -3 for new buildings and 400 Bq m -3 for existing buildings. For mines and underground excavations, however, there are some differences. The treatment of gamma emitting natural radionuclides in building materials etc. is similar, although there are differences in the degree of control. The action levels for 222 Rn in drinking water differ from 100 Bq l -1 to 500 Bq l -1 . The action level in Finland has the form of an activity index that restricts also other radioactive nuclides. Denmark has not adopted a formal radon policy and has no recommended or legally binding action levels for 222 Rn or any other naturally occurring radionuclides. (author)

  19. High concentrations of radon. Specifically affected buildings; Hohe Radonkonzentrationen. Besonders betroffene Gebaeudetypen

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Winfried [Bundesamt fuer Strahlenschutz, Berlin (Germany)

    2015-07-01

    The paper presents a concept for the prognosis of exceeding probabilities of thresholds of radon in dwellings in different building types. A transfer model for the interface subsoil - building was used as a basis. The partial datasets obtained by stratification of five relevant building characteristics can be de-scribed by a 3-parametric-lognormal distribution good in most times. The available data permit statistical predictions to 60 combinations of building characteristics for the region ''east'' and 85 combinations of building characteristics for the region ''West''. The uncertainties for the probability of exceeding a threshold were estimated from the data with bootstrapping. The importance of different building characteristics for the presence of enhanced radon concentrations can be predicted from the results of this estimation. Therefore, targeting of affected buildings is possible on this basis. Regional prognoses of exceeding probabilities for building types with high presence can also be created by the use of transfer factors. A Strategy to reduce the health risk from radon in the long run might be derived, where alongside the delineation of radon prone areas, special attention should be paid to a set out building characteristics, also outside the radon prone areas.

  20. Building

    OpenAIRE

    Seavy, Ryan

    2014-01-01

    Building for concrete is temporary. The building of wood and steel stands against the concrete to give form and then gives way, leaving a trace of its existence behind. Concrete is not a building material. One does not build with concrete. One builds for concrete. MARCH

  1. Energy savings potential from improved building controls for the US commercial building sector

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin; Xie, Yulong; Zhao, Mingjie

    2017-09-27

    %; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

  2. Draught risk index tool for building energy simulations

    DEFF Research Database (Denmark)

    Vorre, Mette Havgaard; Jensen, Rasmus Lund; Nielsen, Peter V.

    2014-01-01

    Flow elements combined with a building energy simulation tool can be used to indicate areas and periods when there is a risk of draught in a room. The study tests this concept by making a tool for post-processing of data from building energy simulations. The objective is to show indications...... of draught risk during a whole year, giving building designers a tool for the design stage of a building. The tool uses simple one-at-a-time calculations of flow elements and assesses the uncertainty of the result by counting the number of overlapping flow elements. The calculation time is low, making...... it usable in the early design stage to optimise the building layout. The tool provides an overview of the general draught pattern over a period, e.g. a whole year, and of how often there is a draught risk....

  3. Thermal insulating system particularly adapted for building construction

    International Nuclear Information System (INIS)

    Dyar, H.G.

    1985-01-01

    This disclosure relates to an insulating system which is particularly adapted for insulating the walls, floors, ceilings and like structure of buildings and includes a panel having a hollow chamber or interior under negative pressure (vacuum) and being of a variety of external peripheral sizes and shapes to fit within areas defined by wall and/or floor and/or ceiling studs, beams, or the like, a plurality of springs, chains or the like for supporting the panel in generally spaced relationship to an associated building wall, ceiling, floor or like structure, and a plurality of pin-like elements of relatively small cross-sectional configuration normally spaced from the exterior surface of the panel for contacting a limited exterior surface area of the panel only upon the springs, chains or the like becoming inoperative which would in the absence of the pin-like elements result in direct contact between the panel and the associated building wall, ceiling, floor or like structure and thus reduce the insulating efficiency thereof

  4. Towards a Very Low Energy Building Stock: Modeling the U.S. Commercial Building Sector to Support Policy and Innovation Planning

    Energy Technology Data Exchange (ETDEWEB)

    Coffey, Brian; Borgeson, Sam; Selkowitz, Stephen; Apte, Josh; Mathew, Paul; Haves, Philip

    2009-07-01

    This paper describes the origin, structure and continuing development of a model of time varying energy consumption in the US commercial building stock. The model is based on a flexible structure that disaggregates the stock into various categories (e.g. by building type, climate, vintage and life-cycle stage) and assigns attributes to each of these (e.g. floor area and energy use intensity by fuel type and end use), based on historical data and user-defined scenarios for future projections. In addition to supporting the interactive exploration of building stock dynamics, the model has been used to study the likely outcomes of specific policy and innovation scenarios targeting very low future energy consumption in the building stock. Model use has highlighted the scale of the challenge of meeting targets stated by various government and professional bodies, and the importance of considering both new construction and existing buildings.

  5. China building energy consumption: Situation, challenges and corresponding measures

    International Nuclear Information System (INIS)

    Cai, W.G.; Wu, Y.; Zhong, Y.; Ren, H.

    2009-01-01

    As one of the biggest parts of total national energy consumption (TNEC), building energy consumption (BEC) catches public eyes and has been regarded as a crucial problem of the current society. For the past 20 years, BEC in china has been increasing at a high speed. To curb the rapid growing of BEC, china has enforced and implemented a series of policies. These include enforcing BEC constraints on new building projects, promoting more environment friendly building designs, establishing a more sophisticated legislation for building energy conservation, and increasing the total budget in the area of BEC control. This article analyzed china BEC situation and the challenges. As the main point, the measures required by China government to improve building energy efficiency were introduced as well.

  6. Urbanization and its impacts on founded areas of big cities in pakistan: case studies of ichra and sanda areas in lahore

    International Nuclear Information System (INIS)

    Aziz, A.; Mayo, S.M.

    2015-01-01

    Urbanization put immense pressure on urban infrastructure and services. Burdened with unrelenting pressure, the founded areas of Lahore have now been converted into slums. Poor services, urban infrastructure and dilapidated building have made lives of the resident miserable. A significant proportion of the people is living in dangerous buildings which could be declared unfit for habitation under section 34 of Punjab Local Government Ordinance 2001 (PLGO 2001). The paper attempts to highlight situations of two founded areas of Lahore namely, Icchra and Sanda in comparison with slums areas to grade living standards of the people. Actions under PLGO 2001 and urban renewal programs are suggested to revitalize such areas. (author)

  7. Buildings vs. ballistics: Quantifying the vulnerability of buildings to volcanic ballistic impacts using field studies and pneumatic cannon experiments

    Science.gov (United States)

    Williams, G. T.; Kennedy, B. M.; Wilson, T. M.; Fitzgerald, R. H.; Tsunematsu, K.; Teissier, A.

    2017-09-01

    Recent casualties in volcanic eruptions due to trauma from blocks and bombs necessitate more rigorous, ballistic specific risk assessment. Quantitative assessments are limited by a lack of experimental and field data on the vulnerability of buildings to ballistic hazards. An improved, quantitative understanding of building vulnerability to ballistic impacts is required for informing appropriate life safety actions and other risk reduction strategies. We assessed ballistic impacts to buildings from eruptions at Usu Volcano and Mt. Ontake in Japan and compiled available impact data from eruptions elsewhere to identify common damage patterns from ballistic impacts to buildings. We additionally completed a series of cannon experiments which simulate ballistic block impacts to building claddings to investigate their performance over a range of ballistic projectile velocities, masses and energies. Our experiments provide new insights by quantifying (1) the hazard associated with post-impact shrapnel from building and rock fragments; (2) the effect of impact obliquity on damage; and (3) the additional impact resistance buildings possess when claddings are struck in areas directly supported by framing components. This was not well identified in previous work which may have underestimated building vulnerability to ballistic hazards. To improve assessment of building vulnerability to ballistics, we use our experimental and field data to develop quantitative vulnerability models known as fragility functions. Our fragility functions and field studies show that although unreinforced buildings are highly vulnerable to large ballistics (> 20 cm diameter), they can still provide shelter, preventing death during eruptions.

  8. Community Building Services Training Program: A Model Training Program to Provide Technical Training for Minority Adults in Construction, Building Maintenance,and Property Management. Final Report.

    Science.gov (United States)

    Community Building Maintenance Corp., Chicago, IL.

    A demonstration program, administered by a community based building maintenance, management, and construction corporation, was developed to provide technical training for minority adults in construction, building maintenance, and property management in the Chicago area. The program was concerned with seeking solutions to the lack of housing, job…

  9. 300 Area steam plant replacement, Hanford Site, Richland, Washington: Environmental assessment

    International Nuclear Information System (INIS)

    1997-03-01

    Steam to support process operations and facility heating is currently produced by a centralized oil-fired plant located in the 300 Area and piped to approximately 26 facilities in the 300 Area. This plant was constructed during the 1940s and, because of tis age, is not efficient, requires a relatively large operating and maintenance staff, and is not reliable. The US Department of Energy is proposing an energy conservation measure for a number of buildings in the 300 Area of the Hanford Site. This action includes replacing the centralized heating system with heating units for individual buildings or groups of buildings, constructing new natural gas pipelines to provide a fuel source for many of these units and constructing a central control building to operate and maintain the system. A new steel-sided building would be constructed in the 300 Area in a previously disturbed area at least 400 m (one-quarter mile) from the Columbia River, or an existing 300 Area building would be modified and used. This Environmental Assessment evaluates alternatives to the proposed actions. Alternatives considered are: (1) the no action alternative; (2) use of alternative fuels, such as low-sulfur diesel oil; (3) construction of a new central steam plant, piping and ancillary systems; (4) upgrade of the existing central steam plant and ancillary systems; and (5) alternative routing of the gas distribution pipeline that is a part of the proposed action. A biological survey and culture resource review and survey were also conducted

  10. Building-Based Analysis of the Spatial Provision of Urban Parks in Shenzhen, China

    Directory of Open Access Journals (Sweden)

    Wenxiu Gao

    2017-12-01

    Full Text Available Urban parks provide important environmental, social, and economic benefits to people and urban areas. The literature demonstrates that proximity to urban parks is one of the key factors influencing people’s willingness to use them. Therefore, the provision of urban parks near residential areas and workplaces is one of the key factors influencing quality of life. This study designed a solution based on the spatial association between urban parks and buildings where people live or work to identify whether people in different buildings have nearby urban parks available for their daily lives. A building density map based on building floor area (BFA was used to illustrate the spatial distribution of urban parks and five indices were designed to measure the scales, service coverage and potential service loads of urban parks and reveal areas lacking urban park services in an acceptable walking distance. With such solution, we investigated the provision of urban parks in ten districts of Shenzhen in China, which has grown from several small villages to a megacity in only 30 years. The results indicate that the spatial provision of urban parks in Shenzhen is not sufficient since people in about 65% of the buildings cannot access urban parks by walking 10-min. The distribution and service coverage of the existing urban parks is not balanced at the district level. In some districts, the existing urban parks have good numbers of potential users and even have large service loads, while in some districts, the building densities surrounding the existing parks are quite low and at the same time there is no urban parks nearby some high-density areas.

  11. Building-Based Analysis of the Spatial Provision of Urban Parks in Shenzhen, China.

    Science.gov (United States)

    Gao, Wenxiu; Lyu, Qiang; Fan, Xiang; Yang, Xiaochun; Liu, Jiangtao; Zhang, Xirui

    2017-12-06

    Urban parks provide important environmental, social, and economic benefits to people and urban areas. The literature demonstrates that proximity to urban parks is one of the key factors influencing people's willingness to use them. Therefore, the provision of urban parks near residential areas and workplaces is one of the key factors influencing quality of life. This study designed a solution based on the spatial association between urban parks and buildings where people live or work to identify whether people in different buildings have nearby urban parks available for their daily lives. A building density map based on building floor area (BFA) was used to illustrate the spatial distribution of urban parks and five indices were designed to measure the scales, service coverage and potential service loads of urban parks and reveal areas lacking urban park services in an acceptable walking distance. With such solution, we investigated the provision of urban parks in ten districts of Shenzhen in China, which has grown from several small villages to a megacity in only 30 years. The results indicate that the spatial provision of urban parks in Shenzhen is not sufficient since people in about 65% of the buildings cannot access urban parks by walking 10-min. The distribution and service coverage of the existing urban parks is not balanced at the district level. In some districts, the existing urban parks have good numbers of potential users and even have large service loads, while in some districts, the building densities surrounding the existing parks are quite low and at the same time there is no urban parks nearby some high-density areas.

  12. Global climate-oriented building energy use scenarios

    International Nuclear Information System (INIS)

    Harvey, L.D. Danny

    2014-01-01

    This paper explores the extent to which global fuel use in buildings could be reduced, and the growth in global electricity use in buildings limited, by applying stringent (factor of 3–4) improvements to recent building codes for new buildings worldwide and large (factor of 2–3) reductions in the energy use of existing buildings through renovations. The analysis is carried out for 10 different socio-economic regions of the world, taking into account existing building stock and energy intensities in each region and projected changes in population and income, which in most parts of the world will drive large increases in building floor area. A stock turnover model is applied to project changes in heating, cooling, service hot water (SHW) and non-thermal electricity demand with various rates of improvement in standards for new and renovated buildings, and various rates of renovation and demolition of existing buildings. For a scenario in which population peaks at about 9 billion and global average per capita GDP increases to twice the 2010 value by 2100, the global fuel demand could be reduced by a factor of four while limiting maximum annual electricity demand to twice the 2010 value. - Highlights: • A detailed model for generating global scenarios of building energy use is presented. • Drivers of increasing energy use are population and per capita GDP in 10 regions. • Heating, cooling and ventilation energy uses are projected using a stock turnover model. • Global building fuel demand could decrease by 60–80% by 2100 relative to 2010. • Global building electricity demand could be limited to a 100–200% increase

  13. Measurement methods of building structures deflections

    Directory of Open Access Journals (Sweden)

    Wróblewska Magdalena

    2018-01-01

    Full Text Available Underground mining exploitation is leading to the occurrence of deformations manifested by, in particular, sloping terrain. The structures situated on the deforming subsoil are subject to uneven subsidence which is leading in consequence to their deflection. Before a building rectification process takes place by, e.g. uneven raising, the structure's deflection direction and value is determined so that the structure is restored to its vertical position as a result of the undertaken remedial measures. Deflection can be determined by applying classical as well as modern measurement techniques. The article presents examples of measurement methods used considering the measured elements of building structures’ constructions and field measurements. Moreover, for a given example of a mining area, the existing deflections of buildings were compared with mining terrain sloping.

  14. Low-energy district heating in energy-efficient building areas

    DEFF Research Database (Denmark)

    Dalla Rosa, Alessandro; Christensen, Jørgen Erik

    2011-01-01

    of a low-energy network for low-energy houses in Denmark. We took into account the effect of human behaviour on energy demand, the effect of the number of buildings connected to the network, a socio-economic comparison with ground source heat pumps, and opportunities for the optimization of the network...... to 0.20 MWh/(m year), and that the levelized cost of energy in low-energy DH supply is competitive with a scenario based on ground source heat pumps. The investment costs represent up to three quarters of the overall expenditure, over a time horizon of 30 years; so, the implementation of an energy...... system that fully relies on renewable energy needs substantial capital investment, but in the long term this is sustainable from the environmental and socio-economic points of view. Having demonstrated the value of the low-energy DH concept, we evaluated various possible designs with the aim of finding...

  15. Natural radionuclide and radiological assessment of building materials in high background radiation areas of Ramsar, Iran.

    Science.gov (United States)

    Bavarnegin, Elham; Moghaddam, Masoud Vahabi; Fathabadi, Nasrin

    2013-04-01

    Building materials, collected from different sites in Ramsar, a northern coastal city in Iran, were analyzed for their natural radionuclide contents. The measurements were carried out using a high resolution high purity Germanium (HPGe) gamma-ray spectrometer system. The activity concentration of (226)Ra, (232)Th, and (40)K content varied from below the minimum detection limit up to 86,400 Bqkg(-1), 187 Bqkg(-1), and 1350 Bqkg(-1), respectively. The radiological hazards incurred from the use of these building materials were estimated through various radiation hazard indices. The result of this survey shows that values obtained for some samples are more than the internationally accepted maximum limits and as such, the use of them as a building material pose significant radiation hazard to individuals.

  16. Buildings and Terrain of Urban Area Point Cloud Segmentation based on PCL

    International Nuclear Information System (INIS)

    Liu, Ying; Zhong, Ruofei

    2014-01-01

    One current problem with laser radar point data classification is building and urban terrain segmentation, this paper proposes a point cloud segmentation method base on PCL libraries. PCL is a large cross-platform open source C++ programming library, which implements a large number of point cloud related efficient data structures and generic algorithms involving point cloud retrieval, filtering, segmentation, registration, feature extraction and curved surface reconstruction, visualization, etc. Due to laser radar point cloud characteristics with large amount of data, unsymmetrical distribution, this paper proposes using the data structure of kd-tree to organize data; then using Voxel Grid filter for point cloud resampling, namely to reduce the amount of point cloud data, and at the same time keep the point cloud shape characteristic; use PCL Segmentation Module, we use a Euclidean Cluster Extraction class with Europe clustering for buildings and ground three-dimensional point cloud segmentation. The experimental results show that this method avoids the multiple copy system existing data needs, saves the program storage space through the call of PCL library method and class, shortens the program compiled time and improves the running speed of the program

  17. Towards green buildings: Glass as a building element-the use and misuse in the gulf region

    Energy Technology Data Exchange (ETDEWEB)

    Aboulnaga, Mohsen M. [College of Design and Applied Arts, Dubai University College, Dubai P.O. Box 14143 (United Arab Emirates)

    2006-04-15

    The recent economic growth in the Gulf region notably in Dubai, United Arab Emirates (UAE) has led to a colossal number of buildings that has been constructed in the past 5 years. In the last decade, a total glazed building's facades became the icon of Dubai. This large area of glazing in each facade needs protection against overheating and sun glare in summer. According to leader in energy and environmental design (LEED) glass selection becomes a main element in this equation to contribute towards achieving a green building. The aim of this paper is to investigate the problems associated with misuse of glass, as a building element in UAE particularly in Dubai. Inadequate design with ill-selected glass/glazing type may lead not only to poor daylighting in building interiors but also contribute significantly to fatigue, insomnia, seasonal affective disorder (SAD) and above all increase CO{sub 2} emission. The purpose of the study is to specify the required improvements to permit natural, 'free' daylight to filter through the building facade into interior space, especially with the right type of glass. This paper examines the status of buildings in Dubai in terms of glass type, visible light transmittance, reflection (out/in) and relative heat gain. A quantitative analysis is conducted to assess the impact of glass on the building users' performance in terms of daylight environment. A recent built high-rise office building was selected in the investigation to asses whether selected glass provide the recommended daylight factor (DF) and daylight level (DL) according to IES standards. The results revealed that most the glass/glazing was misused in 70% of buildings in intermediate and low performance groups. The DF and DD in the selected office building were unexpectedly tremendous and found far beyond the recommended level due to the use of spectrally selective glazing (clear on both sides). [Author].

  18. Structural wood products in onshore buildings at Naval Station Norfolk, 2000.

    Science.gov (United States)

    David B. McKeever

    2003-01-01

    As of December 31, 2000, there were 603 buildings at Naval Station (NAVSTA) Norfolk with a combined floor area of nearly 17.3 million ft2. In one-third of these buildings, structural wood products were used in one or more major structural building applications, utilizing an estimated 11.6 million board feet of lumber, 0.4 million ft2 (3/8-in. basis) of structural...

  19. Canister storage building natural phenomena design loads

    International Nuclear Information System (INIS)

    Tallman, A.M.

    1996-02-01

    This document presents natural phenomena hazard (NPH) loads for use in the design and construction of the Canister Storage Building (CSB), which will be located in the 200 East Area of the Hanford Site

  20. Merging building maintainability and sustainability assessment: A multicriteria decision making approach

    Science.gov (United States)

    Asmone, A. S.; Chew, M. Y. L.

    2018-02-01

    Accurately predicting maintainability has been a challenge due to the complex nature of buildings, yet it is an important research area with a rising necessity. This paper explores the use of multicriteria decision making approach for merging maintainability and sustainability elements into building grading systems to attain long-term sustainability in the building industry. The paper conducts a systematic literature review on multicriteria decision analysis approach and builds on the existing knowledge of maintainability to achieve this. A conceptual framework is developed to bridge the gap between building operations and maintenance with green facilities management by forecasting green maintainability at the design stage.

  1. Green buildings: Implications for acousticians

    Science.gov (United States)

    Noble, Michael R.

    2005-04-01

    This presentation will deal with the practical implications of green design protocols of the US Green Building Council on interior acoustics of buildings. Three areas of particular consequence to acousticians will be discussed. Ventilation Systems: reduced energy consumption goals dictate reliance on natural cooling and ventilation using ambient air when possible. The consequent large openings in the building envelope to bring fresh air into rooms, and similar sized openings to transfer the mixed air out, can severely compromise the noise isolation of the rooms concerned. Radiant Cooling: the heavy concrete floors of buildings can be used as a thermal flywheel to lessen the cooling load, which forces the concrete ceilings to be exposed to the occupied rooms for heat transfer, and strictly limits the application of acoustical absorption on the ceilings. This challenges the room acoustics design. Green Materials: the LEED protocols require the elimination of potentially harmful finishes, including fibrous materials which may impact air quality or contribute to health problems. Since the backbone of sound absorption is glass and mineral fibres, this further challenges provision of superior room acoustics. Examples and commentary will be provided based on current and recent projects.

  2. The ideal of beauty in the building of recognition marks in ocularcentric societies: the building of the body in blind women in Metropolitan Area in Monterrey

    Directory of Open Access Journals (Sweden)

    Brenda Araceli Bustos García

    2014-12-01

    Full Text Available The aim of this paper is around the question: How do the blind women build the body image? Are they influenced by the hegemonic discourse of the ideal of beauty? At first we define the characteristics of an ocularcentric society. Than once we make a deconstruction of empirical research about the body building in blind women. Finally we present our proposed analysis, relying on narrative psychology, developing a perspective that interprets the building body in blind women as a narrative act through which marks recognition are used to evaluate and classify something as beautiful and attractive. In the analysis of the interviews we found that building of recognition marks has two variables: a one in which certain distrusts and even rejections in the opinions generated is shown by using senses such as smell , touch, etc. (b Other one in which a concept is constructed: tactile aesthetics. Distrust or acceptance of aesthetic tactile is generated mainly by aspects such as: (a age at which they lost the sight (b job they do (c blindness condition time.

  3. FACTOR ANALYSIS OF MULTISTOREY RESIDENTIAL BUILDINGS ZONE

    Directory of Open Access Journals (Sweden)

    Петр Матвеевич Мазуркин

    2016-02-01

    Full Text Available According to the UN classification of 11 classes of soil cover, the first three are grass, trees and shrubs and forests. In the city they correspond to the three elements of vegetation: lawns, tree plantings (trees and shrubs. We have adopted zoning for city-building to identify statistical regularities. Map dimensions in GIS "Map 2011" Yoshkar-Ola was allocated to "residential zone" and "Area of construction of multi-storey residential buildings (cadastral 58 quart crystals". The parameters of the elements of the vegetation cover have been considered: the number of elements of different levels, area and perimeter, the absolute and relative form, and activity of vegetation. As the result, we have obtained equations of binomial rank distributions, conducted the ratings and selected the best of cadastral quarter on environmental conditions.

  4. Hanford B Reactor Building Hazard Assessment Report

    International Nuclear Information System (INIS)

    Griffin, P. W.

    1999-01-01

    The 105-B Reactor (hereinafter referred to as B Reactor) is located in the 100 Area of the Hanford Site near Richland, Washington. The B Reactor is one of nine plutonium production reactors that were constructed in the 1940s during the Cold War Era. Construction of the B Reactor began June 7, 1943, and operation began on September 26, 1944. The Environmental Restoration Contractor was requested by RL to provide an assessment/characterization of the B Reactor building to determine and document the hazards that are present and could pose a threat to the environment and/or to individuals touring the building. This report documents the potential hazards, determines the feasibility of mitigating the hazards, and makes recommendations regarding areas where public tour access should not be permitted

  5. Optimization of pellet–solar combisystems for buildings using a DoE approach

    DEFF Research Database (Denmark)

    Persson, Helena; Carlsson, Bo; Perers, Bengt

    tap water consumption, collector flow rate, tank size, collector area, and estimated wood pellet cost. Cost- and performance-based regression equations were derived for optimal collector area and tank size for a range of buildings, providing tools for individual building solar combisystem sizing...... to inflation and the future price of pellets, and that tank size is less important to system profitability. However, tank insulation and set-point temperature were highly significant....

  6. Intelligent building operating technologies : a cost-effective reduction in building energy consumption[Business case for a climate change solution]. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, J.

    2004-04-01

    Much of the energy consumed in the commercial and institutional (C and I) buildings sector is wasted due to poor building operation. The sector accounts for 13 per cent of secondary energy use in Canada, and contributes about the same proportion of greenhouse gas (GHG) emissions. Energy use in this sector could be reduced if the operation of the buildings were improved. The CANMET Energy Technology Centre in Varennes, Quebec has developed a set of software solutions called Intelligent Building Operating Technologies to address this problem. The software program applies artificial intelligence algorithms to existing building energy management control systems to diagnose equipment and system problems. The software provides performance reports and allows the operator to optimize the operation of the building. The proposed control strategies could be applied to 60 per cent of the building surface area in Canada, resulting energy consumption reductions of 12 per cent annually, or 14 TWh of electricity and 1.5 billion cubic metres of natural gas. The savings amount to $1.8 billion and 7 Mt of GHG emissions annually. It was suggested that a national retro-commissioning program would eliminate the barriers to improving building operation and help research and development aimed at Intelligent Building Operating Technologies. 8 refs., 5 tabs., 3 figs.

  7. Building acoustic regulations in Europe – Brief history and actual situation

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2018-01-01

    Acoustic regulations for housing, educational buildings and some other building categories now exist in most countries in Europe, but findings from comparative studies show that extent and strictness as well as descriptors vary considerably across Europe. The acoustic performance areas dealt with...

  8. 2nd International Conference on Construction and Building Research

    CERN Document Server

    Fernández-Plazaola, Igor; Hidalgo-Delgado, Francisco; Martínez-Valenzuela, María; Medina-Ramón, Francisco; Oliver-Faubel, Inmaculada; Rodríguez-Abad, Isabel; Salandin, Andrea; Sánchez-Grandia, Rafael; Tort-Ausina, Isabel; Construction and Building Research

    2014-01-01

    Many areas of knowledge converge in the building industry and therefore research in this field necessarily involves an interdisciplinary approach. Effective research requires strong relations between a broad variety of scientific and technological domains and more conventional construction or craft processes, while also considering advanced management processes, where all the main actors permanently interact. This publication takes an interdisciplinary approach grouping various studies on the building industry chosen from among the works presented for the 2nd International Conference on Construction and Building Research. The papers examine aspects of materials and building systems; construction technology; energy and sustainability; construction management; heritage, refurbishment and conservation. The information contained within these pages may be of interest to researchers and practitioners in construction and building activities from the academic sphere, as well as public and private sectors.

  9. 300 Area Disturbance Report

    Energy Technology Data Exchange (ETDEWEB)

    LL Hale; MK Wright; NA Cadoret

    1999-01-07

    The objective of this study was to define areas of previous disturbance in the 300 Area of the U.S. Department of Energy (DOE) Hanford Site to eliminate these areas from the cultural resource review process, reduce cultural resource monitoring costs, and allow cultural resource specialists to focus on areas where subsurface disturbance is minimal or nonexistent. Research into available sources suggests that impacts from excavations have been significant wherever the following construction activities have occurred: building basements and pits, waste ponds, burial grounds, trenches, installation of subsurface pipelines, power poles, water hydrants, and well construction. Beyond the areas just mentioned, substrates in the' 300 Area consist of a complex, multidimen- sional mosaic composed of undisturbed stratigraphy, backfill, and disturbed sediments; Four Geographic Information System (GIS) maps were created to display known areas of disturbance in the 300 Area. These maps contain information gleaned from a variety of sources, but the primary sources include the Hanford GIS database system, engineer drawings, and historic maps. In addition to these maps, several assumptions can be made about areas of disturbance in the 300 Area as a result of this study: o o Buried pipelines are not always located where they are mapped. As a result, cultural resource monitors or specialists should not depend on maps depicting subsurface pipelines for accurate locations of previous disturbance. Temporary roads built in the early 1940s were placed on layers of sand and gravel 8 to 12 in. thick. Given this information, it is likely that substrates beneath these early roads are only minimally disturbed. Building foundations ranged from concrete slabs no more than 6 to 8 in. thick to deeply excavated pits and basements. Buildings constructed with slab foundations are more numerous than may be expected, and minimally disturbed substrates may be expected in these locations. Historic

  10. Parameters for Building Materials Specifications in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Clement Oluwole Folorunso

    2013-07-01

    Full Text Available The responsibility of specifying materials for building construction purposes within Nigeria rests on the architects. Understanding the appropriate parameters for specifying building materials that could lead to immense financial proportion is required from the architects. The level of understanding and knowledge of architects is germane to the optimum performance of buildings throughout their life cycle. The methodology applied for this research involved the administration of a structured questionnaire on professional architects within the study area to determine the basis of their decision on the materials they specify or chose for building finishes. The parameters used to measure the specification of materials for finishes are client’s choice, cost, climatic compliance, and maintenance demand of materials. Findings show that the maintenance demand of materials is the most important factor that determines the specification of materials irrespective of the choice of client and climate. However, cost occupies a prominent role in the decision process. It also shows that most architects are not fully aware about the role of climate in determining the life cycle of materials in tropical environments. The compliance of materials to ever-changing climate does not constitute a major factor in the specification of materials in the area.

  11. Building spatial layout that supports healthier behavior of office workers: a new performance mandate for sustainable buildings.

    Science.gov (United States)

    Hua, Ying; Yang, Eunhwa

    2014-01-01

    The pursuit of efficiency and the permeation of communication technologies in modern workplace have increased prolonged sitting and physical inactivity among the white-collar workforce. Physical inactivity is a major risk factor for developing various chronic diseases and obesity. This study intends to understand the impact of physical environment on both voluntary and imperative physical activity levels in an office building, and to collect evidence for design suggestions to encourage office workers' activity level on a daily basis. This study examined how proximity from individual workstations to various shared service and amenity spaces in the workplace (e.g., meeting spaces, copy areas, kitchens, restrooms, elevators, and stairs) is associated with office workers' physical activity level (e.g., sedentary and non-sedentary behavior) and their environmental and job satisfaction. To objectively measure physical activity, twenty-six office workers, in a three-story office building, wore accelerometers for three consecutive days at work. Environmental and job satisfaction of office workers was measured by a questionnaire. Proximity variables were measured using the floor plans of the subject building. Participants on average were sedentary for 80% of the time during the study. Proximity to several service and amenity areas was positively associated with step counts and job satisfaction.

  12. Degraded areas of organised multi-apartment building between 1945 and 1965 in Slovenia – methodology of evaluation and rehabilitation

    Directory of Open Access Journals (Sweden)

    Tadeja Zupančič Strojan

    2002-01-01

    Full Text Available “Degraded” housing areas represent a 9% share of urbanised surfaces of thirty-five in planning terms recently researched Slovenian towns. Above all social housing estates built between 1945 and 1965 present issues since they are isolated, poorly maintained, and cannot reach modern standards. The research contemplates the redirecting of the present abstract planning rationales to the real architectural, user level. Further intentions of the research are to consolidate ideas about the urgency of renewal as the only possible method of solving problems of a certain pattern of building, to determine criteria and measures for renewal and to determine rational or real directions for concrete contributions for the improvement of the standard of living, in short, to a new shift in living culture discussed settlement pattern.

  13. Zero energy buildings and mismatch compensation factors

    DEFF Research Database (Denmark)

    Lund, Henrik; Marszal, Anna Joanna; Heiselberg, Per

    2011-01-01

    This paper takes an overall energy system approach to analysing the mismatch problem of zero energy and zero emission buildings (ZEBs). The mismatch arises from hourly differences in energy production and consumption at the building level and results in the need for exchange of electricity via...... the public grid even though the building has an annual net-exchange of zero. This paper argues that, when looked upon from the viewpoint of the overall electricity supply system, a mismatch can be both negative and positive. Moreover, there are often both an element of levelling out mismatches between...... of the energy production unit. Based on historical data for the electricity supply area in western Denmark, this paper makes a first attempt to quantify mismatch compensation factors. The results indicate that such compensation factors are a little below one for buildings with photovoltaics (PV) and a little...

  14. Integrated structural design of nuclear power plants for high seismic areas

    International Nuclear Information System (INIS)

    Rieck, P.J.

    1979-01-01

    A design approach which structurally interconnects NPP buildings to be located in high seismic areas is described. The design evolution of a typical 600 MWe steel cylindrical containment PWR is described as the plant is structurally upgraded for higher seismic requirements, while maintaining the original plant layout. The plant design is presented as having separate reactor building and auxiliary structures for a low seismic area (0.20 g) and is structurally combined at the foundation for location in a higher seismic area (0.30 g). The evolution is completed by a fully integrated design which structurally connects the reactor building and auxiliary structures at superstructure elevations as well as foundation levels for location in very severe seismic risk areas (0.50 g). (orig.)

  15. Fire Risk Analysis and Optimization of Fire Prevention Management for Green Building Design and High Rise Buildings: Hong Kong Experience

    Directory of Open Access Journals (Sweden)

    Yau Albert

    2014-12-01

    Full Text Available There are many iconic high rise buildings in Hong Kong, for example, International Commercial Centre, International Financial Centre, etc. Fire safety issue in high rise buildings has been raised by local fire professionals in terms of occupant evacuation, means of fire-fighting by fire fighters, sprinkler systems to automatically put off fires in buildings, etc. Fire risk becomes an important issue in building fire safety because it relates to life safety of building occupants where they live and work in high rise buildings in Hong Kong. The aim of this research is to identify the fire risk for different types of high rise buildings in Hong Kong and to optimise the fire prevention management for those high rise buildings with higher level of fire risk and to validate the model and also to carry out the study of the conflict between the current fire safety building code and the current trend of green building design. Survey via the 7-point scale questionnaire was conducted through 50 participants and their responses were received and analysed via the statistical tool SPSS software computer program. A number of statistical methods of testing for significantly difference in samples were adopted to carry out the analysis of the data received. When the statistical analysis was completed, the results of the data analysis were validated by two Fire Safety Experts in this area of specialisation and also by quantitative fire risk analysis.

  16. Building Better Buildings: Sustainable Building Activities in California Higher Education Systems.

    Science.gov (United States)

    Sowell, Arnold; Eichel, Amanda; Alevantis, Leon; Lovegreen, Maureen

    2003-01-01

    This article outlines the activities and recommendations of California's sustainable building task force, discusses sustainable building activities in California's higher education systems, and highlights key issues that California is grappling with in its implementation of sustainable building practices. (EV)

  17. Distribution of projected area factors exhibited by occupants of a tertiary institutional building in the hot-humid tropics for thermal comfort evaluation

    International Nuclear Information System (INIS)

    Ijhar Hidayat Rusli; Nor Mariah Adam; Nawal Aswan Abdul Jalil

    2009-01-01

    Full text: One of the factors that affect the thermal comfort levels of occupants of a built environment is the amount of heat exchange they engage in with the short-wave radiation originating from the sun. In quantifying this phenomenon, it is necessary to determine the projected area factors between an occupant and the geometrical location of the sun. This paper presents the projected area factors of an occupant of a tertiary institutional building exposed to short-wave radiation from the sun at different hours of a day throughout a year. It is seen that, for the current case studied, the months June and July show the highest projected area factors among all 12 months. This suggests that it is within these months that the interaction between an occupant and the radiant heat from the sun is greatest. An example of how the projected area factors can be used in thermal comfort evaluation is also presented incorporating actual measured irradiance values over a period of time. Such analysis and the information it provides allows for a more detailed investigation of the thermal comfort levels of a built environment in relation to fenestration design and can be coupled with day lighting analysis in virtue of a sustainable built environment. (author)

  18. Maths for the building trades

    CERN Document Server

    Kidd, Jim

    2014-01-01

    Maths for the Building Trades provides students of all ages with an easy-to-understand guide to the fundamental mathematics that is required in their area of study and beyond. It can be used as a learning programme on its own or in conjunction with the textbooks associated with their chosen trade. The book assumes only a minimum level of mathematical knowledge and thoroughly covers the basic rules. It then goes on to fully explain some of the more complex areas in which the student will be required to demonstrate competence.

  19. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  20. 2016 Building Technologies Office Peer Review Report

    Energy Technology Data Exchange (ETDEWEB)

    Building Technologies Office

    2016-12-01

    The 2016 Building Technologies Office Peer Review Report summarizes the feedback submitted by reviewers of the 67 BTO projects presented at the 2016 BTO Peer Review. The report presents an overview of the goals and activities under each technology program area, a summary of project scores for each program, and a brief analysis of general evaluation trends within each program area or its constituent subprograms.

  1. INFLUENCE OF PIT WALL ANCHORAGE ONTO ADDITIONAL DEFORMATIONS OF EXISTING BUILDINGS

    Directory of Open Access Journals (Sweden)

    Kubetskiy Valeriy Leonidovich

    2012-07-01

    Assessment of additional projected deformations of buildings located in close proximity to pits is exemplified by the specific structure of the pit support system that has active PIT [1] anchors. The authors also consider the influence produced by the structure of anchors onto the two buildings located within the area of influence of the excavation works and protected by the anchors installed underneath the foundations of the two adjacent buildings.

  2. 327 Building fire hazards analysis implementation plan

    International Nuclear Information System (INIS)

    Eggen, C.D.

    1998-01-01

    In March 1998, the 327 Building Fire Hazards Analysis (FRA) (Reference 1) was approved by the US Department of Energy, Richland Operations Office (DOE-RL) for implementation by B and W Hanford Company (B and WHC). The purpose of the FHA was to identify gaps in compliance with DOE Order 5480.7A (Reference 2) and Richland Operations Office Implementation Directive (RLID) 5480.7 (Reference 3), especially in regard to loss limitation. The FHA identified compliance gaps in five areas and provided nine recommendations (11 items) to bring the 327 Building into compliance. To date, actions for five of the 11 items have been completed. Exemption requests will be transmitted to DOE-RL for two of the items. Corrective actions have been identified for the remaining four items. The completed actions address combustible loading requirements associated with the operation of the cells and support areas. The status of the recommendations and actions was confirmed during the July 1998 Fire Protection Assessment. B and WHC will use this Implementation Plan to bring the 327 Building and its operation into compliance with DOE Order 5480.7A and RLID 5480.7

  3. Influence of windows on the energy balance of apartment buildings in Amman

    International Nuclear Information System (INIS)

    Hassouneh, K.; Alshboul, A.; Al-Salaymeh, A.

    2010-01-01

    The influence of windows on the energy balance of apartment buildings in Amman is investigated by using self developed simulation software (SDS) based on the ASHRAE tables for solar heat gain calculation and coaling load factor for latitude 32 deg., where Amman city is located. The calculations of energy saving are made to find out the influence of windows on the energy balance of apartment buildings in Amman. Also, the present investigation aimed to study the energy performance of windows of an apartment building in Amman in order to select the most energy efficient windows that can save more energy and reduce heating load in winter, the percentage of saving energy and saving fuel and money through time. Variations of type of glazing using eight types of glazing (clear glass, types A, B, C, D, E, F, and G) are made to find out the most appropriate type of glazing in each direction. Also the orientation of window is changeable in the main four directions (N, S, E and W). The area of glazing varies also in different orientation to find the influence of window area on the thermal balance of the building. The results show that if energy efficient windows are used, the flexibility of choosing the glazed area and orientation increases. It has been found that choosing a larger area facing south, east and west can save more energy and decrease heating costs in winter using certain types of glazing such as glass type A and clear glass, while decreasing the glazing area facing north can save money and energy. However, it has been found that the energy can be saved in the north direction if glass type B has been used. In the apartment building, it is found that certain combination of glazing is energy efficient than others. This combination consists of using large area of glass type A in the east, west and south direction, and glass type B in the north direction or reducing glazing area as possible in the north direction.

  4. Investigation on Adaptive Re-use of Heritage Building in George Town, Penang

    Directory of Open Access Journals (Sweden)

    Marhamah Abdul Hadi

    2013-09-01

    Full Text Available Adaptive re-use of heritage buildings in George Town has gained attention from their owners. Their owners either private owners or government, want to adapt their respective buildings to new usage for instance to become a gallery, museum, restaurant, boutique hotel and many more. Every heritage building that is being adapted to paper main objective is to identify the changes made in terms of structure, space and material when adapting the heritage buildings to a new usage specifically into a gallery. Two heritage buildings are chosen as case studies for this paper which are Rumah Teh Bunga and Fort Cornwallis; both buildings located in Penang, Malaysia. The changes made to these two buildings were analyzed using the guidelines provided which are Guideline for Conservation areas and Heritage Buildings and National Heritage Acts 2005. Both buildings will be analyzed using National Heritage Acts, while only Fort Cornwallis will be analyzed using Guideline for Conservation areas and Heritage Buildings. Adaptation of these two heritage buildings requires changes in structure, space and material. The changes in Rumah Teh Bunga focuses more on materials and space while changes in Fort Cornwallis emphasize more to space and addition of other structures. Analysis on the changes are made by using the guideline provided, most of the changes made to both of these heritage buildings comply the rules and regulations stated in the guideline. It was found from the data that some of the reasons on why the owner change Rumah Teh Bunga to gallery are because of its complicated procedure that involves in privatization of this building to other owner and the need to promote the heritage significance of this building to the public. As for Fort Cornwallis, the adaptation is more on strengthening its value as a fort and becoming a tourist attraction.

  5. Worldwide status of energy standards for buildings: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Janda, K.B.; Busch, J.F.

    1993-02-01

    This informal survey was designed to gain information about the worldwide status of energy efficiency standards for buildings, particularly non-residential buildings such as offices, schools, and hotels. The project has three goals: 1. To understand and learn from the experience of countries with existing building energy standards; 2. To locate areas where these lessons might be applied and energy standards might be effectively proposed and developed; and 3. To share the information gathered with all participating countries. These appendices include the survey cover letter, the survey, and the details of selected energy standards in 35 countries, thus providing supporting material for the authors` article of the same title.

  6. Using Specification and Description Language for Life Cycle Assesment in Buildings

    Directory of Open Access Journals (Sweden)

    Pau Fonseca i Casas

    2017-06-01

    Full Text Available The definition of a Life Cycle Assesment (LCA for a building or an urban area is a complex task due to the inherent complexity of all the elements that must be considered. Furthermore, a multidisciplinary approach is required due to the different sources of knowledge involved in this project. This multidisciplinary approach makes it necessary to use formal language to fully represent the complexity of the used models. In this paper, we explore the use of Specification and Description Language (SDL to represent the LCA of a building and residential area. We also introduce a tool that uses this idea to implement an optimization and simulation mechanism to define the optimal solution for the sustainability of a specific building or residential.

  7. Sustainable Building in Scandinavia: Directions of Innovations for Supporting the Transition

    DEFF Research Database (Denmark)

    Koch-Ørvad, Nina; Thuesen, Christian

    2016-01-01

    Buildings are essential for securing a sustainable society, and the Scandinavian building sector is viewed upon globally as the one to lead the way. This paper investigates in which directions sustainable building in Scandinavia is likely to move and outlines a number of areas where sustainable...... in novations are necessary for supporting this movement. The focus on innovations as essential support for the sustainable transition of the building sector derives from the Multi-Level Perspective, which has been applied to this study as a framework for understanding sustainable transitions of socio...

  8. Design of an increase in the CNAAA unit I South auxiliary building

    International Nuclear Information System (INIS)

    Lorentz, R.G.; Loyola Benedicto Ottoni, I. de; Roech, J.L.

    1990-01-01

    In this work it is presented the description of the model adopted in the structural calculations for a modification in the CNAAA Unit I South Auxiliary Building. This modification intended to increase the facilities destinated to keeping and changing of special clothing for access to the controlled area. The design basically constitutes of a slab at the Elevation 5,15m, for which a tridimensional frame model was adopted, in reinforced adopted concrete, fixed in the South Auxiliary Building foundation slab and structurally independent on the building, at the slab level. It was demonstrated in this study that the introduction, in the existing structure, of the masses of this enlarged area does not considerably change the dynamic behaviour of the building, which allowed proceeding the analysis of the new structure independently of the existing one. (author)

  9. UP-report. Buildings in the energy system. Basis of the Development platform. Build to the Swedish Energy Agency's strategy work FOKUS; UP-rapport. Byggnader i energisystemet. Underlag fraan Utvecklingsplattformen. Bygg till Energimyndighetens strategiarbete FOKUS

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-11-01

    The report serves as input to the Swedish Energy Agency's strategies and priorities for research and innovation in the thematic area buildings in the energy system for the period 2011 - 2016. The report has been compiled by members of the development platform Build. This report provides background and the conditions of the area buildings in the energy system, and proposed priorities and activities for future efforts in this area. The development platform has contributed with valuable experience and knowledge which enabled the Swedish Energy Agency to then develop a strategy that meets the needs of the society and business.

  10. Initial building investigations at Aberdeen Proving Ground, Maryland: Objectives and methodology

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, K.L.; Dougherty, J.M.; McGinnis, L.D.

    1994-12-01

    As part of an environmental-contamination source-definition program at Aberdeen Proving Ground, detailed internal and external inspections of 23 potentially contaminated buildings are being conducted to describe and characterize the state of each building as it currently exists and to identify areas potentially contaminated with toxic or other hazardous substances. In addition, a detailed geophysical investigation is being conducted in the vicinity of each target building to locate and identify subsurface structures, associated with former building operations, that are potential sources of contamination. This report describes the objectives of the initial building inspections, including the geophysical investigations, and discusses the methodology that has been developed to achieve these objectives.

  11. Sustainable Building in China—A Green Leap Forward?

    Directory of Open Access Journals (Sweden)

    Jialiang Wang

    2013-09-01

    Full Text Available China is constructing new commercial buildings at an enormous rate—roughly 2 billion square meters per year, with considerable interest and activity in green design and construction. We review the context of commercial building design and construction in China, and look at a specific project as an example of a high performance, sustainable design, the Shenzhen Institute of Building Research (IBR. The IBR building incorporates over 40 sustainable technologies and strategies, including daylighting, natural ventilation, gray-water recycling, solar-energy generation, and highly efficient Heating Ventilation and Air Conditioning (HVAC systems. We present measured data on the performance of the building, including detailed analysis by energy end use, water use, and occupant comfort and satisfaction. Total building energy consumption in 2011 was 1151 MWh, with an Energy Use Intensity (EUI of 63 kWh/m2 (20 kBtu/ft2, which is 61% of the mean EUI value of 103 kWh/m2 (33 kBtu/ft2 for similar buildings in the region. We also comment on the unique design process, which incorporated passive strategies throughout the building, and has led to high occupant satisfaction with the natural ventilation, daylighting, and green patio work areas. Lastly we present thoughts on how the design philosophy of the IBR building can be a guide for low-energy design in different climate regions throughout China and elsewhere.

  12. Assessment of flood potential for eight buildings at the Y-12 Plant

    International Nuclear Information System (INIS)

    Eiffe, M.A.

    1997-01-01

    In 1995, P-SQUARED Technologies, Inc., (P2T) was tasked with defining the flood potential for seven buildings at the Y-12 Plant (Buildings 9204-2, 9204-2E, 9206, 9212, 9215, 9720-5, and 9995) in the assumed event of a design storm with a recurrence interval of 10,000 years. At the conclusion of the study, P2T prepared and submitted a report summarizing the flood potential for those seven buildings. In November of 1997, P2T was tasked with (1) defining flood potential for the same seven buildings listed above for design storms with recurrence intervals of 500 years and 2000 years, and (2) defining flood potential for Building 9720-38 for design storms with recurrence intervals of 500 years, 2000 years, and 10,000 years. This report presents the results of the analyses conducted to define flood potential at these locations and for these recurrence intervals. None of the buildings investigated are completely safe from flooding during the storms considered. Runoff from rooftops may cause limited flooding in any areas where water is allowed to pond next to doors, vents, windows, or other openings. Flooding depths inside buildings in these areas should be limited to 1 ft or less. Buildings with openings below the grade of adjacent roads are also subject to flooding, with flood levels dependent upon the topography in that location

  13. Analysis and Optimization of Building Energy Consumption

    Science.gov (United States)

    Chuah, Jun Wei

    Energy is one of the most important resources required by modern human society. In 2010, energy expenditures represented 10% of global gross domestic product (GDP). By 2035, global energy consumption is expected to increase by more than 50% from current levels. The increased pace of global energy consumption leads to significant environmental and socioeconomic issues: (i) carbon emissions, from the burning of fossil fuels for energy, contribute to global warming, and (ii) increased energy expenditures lead to reduced standard of living. Efficient use of energy, through energy conservation measures, is an important step toward mitigating these effects. Residential and commercial buildings represent a prime target for energy conservation, comprising 21% of global energy consumption and 40% of the total energy consumption in the United States. This thesis describes techniques for the analysis and optimization of building energy consumption. The thesis focuses on building retrofits and building energy simulation as key areas in building energy optimization and analysis. The thesis first discusses and evaluates building-level renewable energy generation as a solution toward building energy optimization. The thesis next describes a novel heating system, called localized heating. Under localized heating, building occupants are heated individually by directed radiant heaters, resulting in a considerably reduced heated space and significant heating energy savings. To support localized heating, a minimally-intrusive indoor occupant positioning system is described. The thesis then discusses occupant-level sensing (OLS) as the next frontier in building energy optimization. OLS captures the exact environmental conditions faced by each building occupant, using sensors that are carried by all building occupants. The information provided by OLS enables fine-grained optimization for unprecedented levels of energy efficiency and occupant comfort. The thesis also describes a retrofit

  14. 324 Building fire hazards analysis implementation plan

    International Nuclear Information System (INIS)

    Eggen, C.D.

    1998-01-01

    In March 1998, the 324 Building Fire Hazards Analysis (FHA) (Reference 1) was approved by the US Department of Energy, Richland Operations Office (DOE-RL) for implementation by B and W Hanford Company (BWHC). The purpose of the FHA was to identify gaps in compliance with DOE Order 5480.7A (Reference 2) and Richland Operations Office Implementation Directive (RLID) 5480.7 (Reference 3), especially in regard to loss limitation. The FHA identified compliance gaps in six areas and provided 20 recommendations to bring the 324 Building into compliance with DOE Order 5480.7A. Additionally, one observation was provided. To date, four of the recommendations and the one observation have been completed. Actions identified for seven of the recommendations are currently in progress. Exemption requests will be transmitted to DOE-RL for three of the recommendations. Six of the recommendations are related to future shut down activities of the facility and the corrective actions are not being addressed as part of this plan. The actions for recommendations associated with the safety related part of the 324 Building and operation of the cells and support areas were evaluated using the Unreviewed Safety Question (USQ) process. Major Life Safety Code concerns have been corrected. The status of the recommendations and actions was confirmed during the July 1998 Fire Protection Assessment. BVMC will use this Implementation Plan to bring the 324 Building and its operation into compliance with DOE Order 5480.7A and RLID 5480.7

  15. Building performance simulation for sustainable buildings

    NARCIS (Netherlands)

    Hensen, J.L.M.

    2010-01-01

    This paper aims to provide a general view of the background and current state of building performance simulation, which has the potential to deliver, directly or indirectly, substantial benefits to building stakeholders and to the environment. However the building simulation community faces many

  16. Brand new hall in the main building

    CERN Multimedia

    Corinne Pralavorio

    2014-01-01

    The renovation of the UNIQA and post office premises is getting under way, with their reopening scheduled for the spring.   The renovation of the large hall in the main building (Building 500) has finally reached the home straight. As of this week, building contractors will get to work on the last part – the offices of UNIQA and La Poste. In the last week of November, the two concessions moved their offices across Route Scherrer to the same part of Building 510 where UBS was temporarily housed during the bank’s refurbishment. Their services were therefore unavailable for one day. The renovation work will last until the spring, with the new offices expected to open in May 2015. Between now and then, the windows and insulation will be completely refitted, with a view to reducing heat loss considerably, and, above all, the premises will be modernised to improve customer reception and service. For example, UNIQA’s new premises will feature a confidential area, guarantee...

  17. Smart renovation of Matrix building : the value of comfort and energy

    NARCIS (Netherlands)

    Khademagha, P.

    2014-01-01

    Currently, TU/e campus is going through a reconstruction phase, in the process towards a more sustainable and compact campus. To keep up with the improvement pace governing the area, old buildings with poor functionality are to be upgraded. The Matrix building, located in the south part of the

  18. The Impact of High-Rise Buildings on the Living Environment

    Directory of Open Access Journals (Sweden)

    Giyasov Botir

    2018-01-01

    Full Text Available Urbanization as a socio-economic process manifested in the concentration of the population in modern big cities contributes to the development of high-rise building construction. With the development of education and culture, changing leisure habits, city residents put forward new architectural and functional requirements to the living environment and urban infrastructure. This calls for the creation of new types and forms of residential buildings, the structure of the city and transport networks. In addition, the need to develop high-rise building construction is justified by the growing demand for residential, public and administrative buildings and the lack of free space.The paper analyzes the development of high-rise building construction in urban areas. The problem of the impact of high-rise building construction in big cities on the living environment is considered. Using analytical methods, causes and sources of pollution, such as transport and engineering infrastructure have been identified. In some urban areas, there are zones with modified thermal conditions and air exchange resulting in the formation of the “urban heat island”The qualitative and quantitative characteristics of variations in temperature and wind speed with respect to the height of the building have been calculated, using the example of the Evolution Tower of the Moscow International Business Center (“Moscow City”. Calculation and comparative analysis for the cities of Moscow, Khanty-Mansiysk and Vladivostok has made it possible to assess the variation in temperature and wind speed and their impact on the living environment under different climatic conditions.

  19. The Impact of High-Rise Buildings on the Living Environment

    Science.gov (United States)

    Giyasov, Botir; Giyasova, Irina

    2018-03-01

    Urbanization as a socio-economic process manifested in the concentration of the population in modern big cities contributes to the development of high-rise building construction. With the development of education and culture, changing leisure habits, city residents put forward new architectural and functional requirements to the living environment and urban infrastructure. This calls for the creation of new types and forms of residential buildings, the structure of the city and transport networks. In addition, the need to develop high-rise building construction is justified by the growing demand for residential, public and administrative buildings and the lack of free space.The paper analyzes the development of high-rise building construction in urban areas. The problem of the impact of high-rise building construction in big cities on the living environment is considered. Using analytical methods, causes and sources of pollution, such as transport and engineering infrastructure have been identified. In some urban areas, there are zones with modified thermal conditions and air exchange resulting in the formation of the "urban heat island"The qualitative and quantitative characteristics of variations in temperature and wind speed with respect to the height of the building have been calculated, using the example of the Evolution Tower of the Moscow International Business Center ("Moscow City"). Calculation and comparative analysis for the cities of Moscow, Khanty-Mansiysk and Vladivostok has made it possible to assess the variation in temperature and wind speed and their impact on the living environment under different climatic conditions.

  20. Radon and the seal offered by the building shell

    International Nuclear Information System (INIS)

    Crameri, R.; Furrer, D.; Burkart, W.

    1992-01-01

    Long term measurements of the radon level before and after the building shell is sealed were carried out in 25 apartment buildings and 7 houses. The average values of the most important meteorological parameters of wind speed, external temperature and barometric pressure which may influence the radon level, were absolutely comparable during the measurement periods before and after the energy renovation of the buildings. Both in houses and in apartment buildings the radon level remained practically unchanged after the building shell was sealed. The lack of any increase in the radon level after reducing the air exchange rate can be explained by virtue of the fact that the balance between the infiltration and elimination of the radon before and after the energy renovation of the buildings remained unchanged. In addition to reducing the air exchange rate, sealing the building shell therefore also results in a reduction in radon infiltration from the soil. Although it is possible in certain cases for the radon level to increase after the building shell has been sealed, a general increase in radon levels inside living areas as a result of energy renovation work can be dismissed. 2 figs., 3 tabs., 30 refs

  1. Establishment of experimental equipments in irradiation technology development building

    International Nuclear Information System (INIS)

    Ishida, Takuya; Tanimoto, Masataka; Shibata, Akira; Kitagishi, Shigeru; Saito, Takashi; Ohmi, Masao; Nakamura, Jinichi; Tsuchiya, Kunihiko

    2011-06-01

    The Neutron Irradiation and Testing Reactor Center has developed new irradiation technologies to provide irradiation data with high technical value for the resume of the Japan Materials Testing Reactor (JMTR). For the purpose to perform assembling of capsules, materials tests, materials inspection and analysis of irradiation specimens for the development of irradiation capsules, improvement and maintenance of facilities were performed. From the viewpoint of effective use of existing buildings in the Oarai research and development center, the RI application development building was refurbished and maintained for above-mentioned purpose. The RI application development building is a released controlled area, and was used as storage of experimental equipments and stationeries. The building was named 'Irradiation Technology Development Building' after it refurbished and maintained. Eight laboratories were maintained based on the purpose of use, and the installation of the experimental apparatuses was started. A basic management procedure of the Irradiation Technology Development Building was established and has been operated. This report describes the refurbish work of the RI application development building, the installation and operation method of the experimental apparatuses and the basic management procedure of the Irradiation Technology Development Building. (author)

  2. Building a capacity building manual

    CSIR Research Space (South Africa)

    Clinton, DD

    2010-02-01

    Full Text Available Organizations 2010 Building a capacity building manual Daniel D. Clinton, Jr., P.E., F.NSPE Chair, WFEO Capacity Building Committee Dr Andrew Cleland, FIPENZ, Chief Executive, IPENZ, NZ Eng David Botha, FSAICE, Executive Director, SAICE, SA Dawit... 2010 Tertiary level University curricula Coaches and mentors Facilities EXCeeD Remuneration of Academics Experiential training Outreach to Students Students chapters Young members forum World Federation of Engineering Organizations 2010 Post...

  3. Continuous Briefing and User Participation in Building Projects

    DEFF Research Database (Denmark)

    Jensen, Per Anker

    2006-01-01

    and the methods for user participation, identifies problem areas and point out possible improvements. The author has been actively involved in the project as deputy project director with re-sponsibility for the briefing process until spring 2005 and is now a researcher.......Briefing is not just about specifying needs as requirements but also about evaluating how well design pro-posals fulfill the needs and aspirations. Furthermore, briefing is not only about building design. Briefing starts at the pre-project stage to create a basis for the project decision...... into the building is required. A building project is often part of a change process of the organisation that is going to occupy the building, and this change process should be management carefully to reach a successful result. An important aspect of briefing is to manage the par-ticipation of the coming users...

  4. Undecomposed Twigs in the Leaf Litter as Nest-Building Resources for Ants (Hymenoptera: Formicidae in Areas of the Atlantic Forest in the Southeastern Region of Brazil

    Directory of Open Access Journals (Sweden)

    Tae Tanaami Fernandes

    2012-01-01

    Full Text Available In tropical forests, the leaf-litter stratum exhibits one of the greatest abundances of ant species. This diversity is associated with the variety of available locations for nest building. Ant nests can be found in various microhabitats, including tree trunks and fallen twigs in different stages of decomposition. In this study, we aimed to investigate undecomposed twigs as nest-building resources in the leaf litter of dense ombrophilous forest areas in the southeastern region of Brazil. Demographic data concerning the ant colonies, the physical characteristics of the nests, and the population and structural of the forest were observed. Collections were performed manually over four months in closed canopy locations that did not have trails or flooded areas. A total of 294 nests were collected, and 34 ant species were recorded. Pheidole, Camponotus, and Hypoponera were the richest genera observed; these genera were also among the most populous and exhibited the greatest abundance of nests. We found no association between population size and nest diameter. Only tree cover influenced the nest abundance and species richness. Our data indicate that undecomposed twigs may be part of the life cycle of many species and are important for maintaining ant diversity in the leaf litter.

  5. Radiological protection principles concerning the safeguard, use or release of contaminated materials, buildings, areas or dumps from uranium mining. Recommendations of the Commission on Radiological Protection with explanations

    International Nuclear Information System (INIS)

    Mueller-Neumann, M.

    1992-01-01

    The volume presents the full texts of the SSK Recommendations addressing the aspects and problems involved, and which can be separately retrieved from the database: 1) Radiological protection principles concerning the release of scrap from the shut-down of uranium mining plants; 2) Radiological protection principles concerning the release for industrial use of areas contaminated from uranium mining; 3) Radiological protection principles concerning the use for forest and agricultural purposes and as public gardens (parks) and residential areas of areas contaminated from uranium mining; 4) Radiological protection principles concerning the safeguard and use of mine dumps; 5) Radiological protection principles concerning the release for further commercial or industrial use of buildings used for commercial or industrial purposes and the disposal of building debris from uranium mining and milling; 6) Radiological protection principles concerning the release for general use of reusable equipment and installations from uranium mining. The following appendices round up the material: 1) Radiation exposure from mining in Saxony and Thuringia and its evaluation (Summary of the results of consultations during the 1990 closed meeting); 2) Radiological protection principles for the limitation of the radiation exposure of the public to radon and its daughters; 3) Epidemiological studies on the health state of the inhabitants of the mining region and the miners in Saxony and Thuringia. (orig.) [de

  6. Extracting Buildings from True Color Stereo Aerial Images Using a Decision Making Strategy

    Directory of Open Access Journals (Sweden)

    Eufemia Tarantino

    2011-07-01

    Full Text Available The automatic extraction of buildings from true color stereo aerial imagery in a dense built-up area is the main focus of this paper. Our approach strategy aimed at reducing the complexity of the image content by means of a three-step procedure combining reliable geospatial image analysis techniques. Even if it is a rudimentary first step towards a more general approach, the method presented proved useful in urban sprawl studies for rapid map production in flat area by retrieving indispensable information on buildings from scanned historic aerial photography. After the preliminary creation of a photogrammetric model to manage Digital Surface Model and orthophotos, five intermediate mask-layers data (Elevation, Slope, Vegetation, Shadow, Canny, Shadow, Edges were processed through the combined use of remote sensing image processing and GIS software environments. Lastly, a rectangular building block model without roof structures (Level of Detail, LoD1 was automatically generated. System performance was evaluated with objective criteria, showing good results in a complex urban area featuring various types of building objects.

  7. A practical approach to compute short-wave irradiance interacting with subgrid-scale buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, Uwe; Frueh, Barbara [Deutscher Wetterdienst, Offenbach am Main (Germany)

    2012-08-15

    A numerical approach for the calculation of short-wave irradiances at the ground as well as the walls and roofs of buildings in an environment with unresolved built-up is presented. In this radiative parameterization scheme the properties of the unresolved built-up are assigned to settlement types which are characterized by mean values of the volume density of the buildings and their wall area density. Therefore it is named wall area approach. In the vertical direction the range of building heights may be subdivided into several layers. In the case of non-uniform building heights the shadowing of the lower roofs by the taller buildings is taken into account. The method includes the approximate calculation of sky view and sun view factors. For an idealized building arrangement it is shown that the obtained approximate factors are in good agreement with exact calculations just as for the comparison of the calculated and measured effective albedo values. For arrangements with isolated single buildings the presented wall area approach yields a better agreement with the observations than similar methods where the unresolved built-up is characterized by the aspect ratio of a representative street canyon (aspect ratio approach). In the limiting case where the built-up is well represented by an ensemble of idealized street canyons both approaches become equivalent. The presented short-wave radiation scheme is part of the microscale atmospheric model MUKLIMO 3 where it contributes to the calculation of surface temperatures on the basis of energy-flux equilibrium conditions. (orig.)

  8. Solar passive buildings for developing countries

    International Nuclear Information System (INIS)

    Gupta, C.L.

    1993-01-01

    This paper is meant to be an indicative survey of developments in solar passive building technology relevant to developing countries. The evolution of this area during the last fifty years is reported along with the scientific principles and design concepts underlying these developments. Factors to be considered for design strategies such as direct gain, isolated gain, indirect gain and roof evaporative systems are then described. Rating parameters for assessing the performance and benefit and cost parameters are then outlined. Successful examples illustrating each of the design concepts, mainly from Indian buildings constructed during the last fifteen years, are then detailed along with their performance based on actual monitoring, if available. Concluding remarks indicate the current and future trends. A survey is made of papers marking significant milestones in the development of solar passive building technology relevant to developing countries. (author). 48 refs., 14 figs., 3 tabs

  9. BUILDING DAMAGE ASSESSMENT AFTER EARTHQUAKE USING POST-EVENT LiDAR DATA

    Directory of Open Access Journals (Sweden)

    H. Rastiveis

    2015-12-01

    Full Text Available After an earthquake, damage assessment plays an important role in leading rescue team to help people and decrease the number of mortality. Damage map is a map that demonstrates collapsed buildings with their degree of damage. With this map, finding destructive buildings can be quickly possible. In this paper, we propose an algorithm for automatic damage map generation after an earthquake using post-event LiDAR Data and pre-event vector map. The framework of the proposed approach has four main steps. To find the location of all buildings on LiDAR data, in the first step, LiDAR data and vector map are registered by using a few number of ground control points. Then, building layer, selected from vector map, are mapped on the LiDAR data and all pixels which belong to the buildings are extracted. After that, through a powerful classifier all the extracted pixels are classified into three classes of “debris”, “intact building” and “unclassified”. Since textural information make better difference between “debris” and “intact building” classes, different textural features are applied during the classification. After that, damage degree for each candidate building is estimated based on the relation between the numbers of pixels labelled as “debris” class to the whole building area. Calculating the damage degree for each candidate building, finally, building damage map is generated. To evaluate the ability proposed method in generating damage map, a data set from Port-au-Prince, Haiti’s capital after the 2010 Haiti earthquake was used. In this case, after calculating of all buildings in the test area using the proposed method, the results were compared to the damage degree which estimated through visual interpretation of post-event satellite image. Obtained results were proved the reliability of the proposed method in damage map generation using LiDAR data.

  10. Energy efficiency indicators for high electric-load buildings

    Energy Technology Data Exchange (ETDEWEB)

    Aebischer, Bernard; Balmer, Markus A.; Kinney, Satkartar; Le Strat, Pascale; Shibata, Yoshiaki; Varone, Frederic

    2003-06-01

    Energy per unit of floor area is not an adequate indicator for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed.

  11. Atmospheric dispersion from releases in the vicinity of buildings

    International Nuclear Information System (INIS)

    Walsh, C.; Jones, J.A.

    2002-01-01

    The objective of this study is to advise FSA on the extent to which its current models for calculating air concentration and deposition for continuous releases close to sites with many buildings are adequate, whether there are circumstances for which the explicit modelling of building wake effects is required, and, if so, to recommend an appropriate model for this. The study considered the predictions of simple Gaussian models and the ADMS model. Results from the models are presented and compared, for a range of on-site building configurations and release locations. In addition, the extent to which details of the buildings on the site are required in ADMS is considered. The results indicate that buildings only affect the predicted concentration in a relatively small area around the site (less than 1 km from the site even for tall buildings). For dose calculations beyond 1 km, no allowance is required for modelling building effects. The results suggest that modelling the effects of buildings can be sensitive to a number of parameters and care should be used in interpreting results for locations within the region affected by buildings. However, because ADMS explicitly treats these factors, it is considered a better model for use than those based on a simple Gaussian approach. (author)

  12. Architectural design of an advanced naturally ventilated building form

    Energy Technology Data Exchange (ETDEWEB)

    Lomas, K.J. [De Montfort University, Leicester (United Kingdom). Institute of Energy and Sustainable Development

    2007-02-15

    Advanced stack-ventilated buildings have the potential to consume much less energy for space conditioning than typical mechanically ventilated or air-conditioned buildings. This paper describes how environmental design considerations in general, and ventilation considerations in particular, shape the architecture of advanced naturally ventilated (ANV) buildings. The attributes of simple and advanced naturally ventilated buildings are described and a taxonomy of ANV buildings presented. Simple equations for use at the preliminary design stage are presented. These produce target structural cross section areas for the key components of ANV systems. The equations have been developed through practice-based research to design three large educational buildings: the Frederick Lanchester Library, Coventry, UK; the School of Slavonic and East European Studies, London, UK; the Harm A. Weber Library, Elgin, near Chicago, USA. These buildings are briefly described and the sizes of the as-built ANV features compared with the target values for use in preliminary design. The three buildings represent successive evolutionary stages: from advanced natural ventilation, to ANV with passive downdraught cooling, and finally ANV with HVAC support. Hopefully the guidance, simple calculation tools and case study examples will give architects and environmental design consultants confidence to embark on the design of ANV buildings. (author)

  13. Radon exhalation rate and natural radionuclide content in building materials of high background areas of Ramsar, Iran.

    Science.gov (United States)

    Bavarnegin, E; Fathabadi, N; Vahabi Moghaddam, M; Vasheghani Farahani, M; Moradi, M; Babakhni, A

    2013-03-01

    Radon exhalation rates from building materials used in high background radiation areas (HBRA) of Ramsar were measured using an active radon gas analyzer with an emanation container. Radon exhalation rates from these samples varied from below the lower detection limit up to 384 Bq.m(-2) h(-1). The (226)Ra, (232)Th and (40)K contents were also measured using a high resolution HPGe gamma- ray spectrometer system. The activity concentration of (226)Ra, (232)Th and (40)K content varied from below the minimum detection limit up to 86,400 Bq kg(-1), 187 Bq kg(-1) and 1350 Bq kg(-1), respectively. The linear correlation coefficient between radon exhalation rate and radium concentration was 0.90. The result of this survey shows that radon exhalation rate and radium content in some local stones used as basements are extremely high and these samples are main sources of indoor radon emanation as well as external gamma radiation from uranium series. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Work at Building 513

    CERN Document Server

    IT Department

    2006-01-01

    As part of IT's preparations to meet the challenge of LHC computing, a new chilled water production unit is being constructed for the Computer Centre. The air conditioning work will start in mid-January and last until June 2006. During this period access to the car park of Building 513 will be restricted. Please consult the plan for details of the area affected by the work. With apologies for the inconvenience, IT Department

  15. Work at Building 513

    CERN Document Server

    IT Department

    2006-01-01

    As part of IT's preparations to meet the challenge of LHC computing, a new chilled water production unit is being constructed for the Computer Centre. The air conditioning work will start in mid-January and last until June 2006. During this period, access to the car park of Building 513 will be restricted. Please consult the plan for details of the area affected by the work. With apologies for the inconvenience. IT Department

  16. Pixel-based approach for building heights determination by SAR radargrammetry

    Science.gov (United States)

    Dubois, C.; Thiele, A.; Hinz, S.

    2013-10-01

    Numerous advances have been made recently in photogrammetry, laser scanning, and remote sensing for the creation of 3D city models. More and more cities are interested in getting 3D city models, be it for urban planning purposes or for supporting public utility companies. In areas often affected by natural disaster, rapid updating of the 3D information may also be useful for helping rescue forces. The high resolutions that can be achieved by the new spaceborne SAR sensor generation enables the analysis of city areas at building level and make those sensors attractive for the extraction of 3D information. Moreover, they present the advantage of weather and sunlight independency, which make them more practicable than optical data, in particular for tasks where rapid response is required. Furthermore, their short revisit time and the possibility of multi-sensor constellation enable providing several acquisitions within a few hours. This opens up the floor for new applications, especially radargrammetric applications, which consider acquisitions taken under different incidence angles. In this paper, we present a new approach for determining building heights, relying only on the radargrammetric analysis of building layover. By taking into account same-side acquisitions, we present the workflow of building height determination. Focus is set on some geometric considerations, pixel-based approach for disparity map calculation, and analysis of the building layover signature for different configurations in order to determine building height.

  17. Retrofit of a Multifamily Mass Masonry Building in New England

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  18. 327 Building fire hazards analysis implementation plan

    International Nuclear Information System (INIS)

    BARILO, N.F.

    1999-01-01

    In March 1998, the 327 Building Fire Hazards Analysis (FHA) (Reference 1) was approved by the U.S. Department of Energy, Richland Operations Office (DOE-E) for implementation by B and W Hanford Company (BWC). The purpose of the FHA was to identify gaps in compliance with DOE Order 5480.7A (Reference 2) and Richland Operations Office Implementation Directive (RLID) 5480.7 (Reference 3), especially in regard to loss limitation. The FHA identified compliance gaps in five areas and provided nine recommendations (11 items) to bring the 327 Building into compliance. A status is provided for each recommendation in this document. BWHC will use this Implementation Plan to bring the 327 Building and its operation into compliance with DOE Order 5480.7A and IUD 5480.7

  19. RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING

    Directory of Open Access Journals (Sweden)

    Ezgi KORKMAZ

    2013-01-01

    Full Text Available There is a big stock of historic structures in Turkey. Many of those structures continue to serve by changing their functions which brings new loads to the building. During their long life, historic structures have experienced many actions occurred over long periods of time and endured long term deteriorating effects and earthquake loads, besides these effects changing of the function affects the load bearing capacity of the building. This study is focused on restoration and retrofitting of historic multi storey masonry building named Deniz Palace Building which is located in Istanbul where the whole city is seismic prone area itself. Earthquake resistance is the main purpose of decision for retrofitting and strengthening of the building. In this sense walls are sheathed by concrete, floors are strengthened by steel I profiles and concrete, and foundations are reconstructed. During the restoration, interventions are made based on prevention of historic values. Static calculations are done particularly. For this purpose, foundation retrofitting is made primarily and some critical walls are sheathed by concrete. Fire protection system is designed and according to the evacuation plan some additions such as elevator shaft are constructed.

  20. Sustainable Building in China -- A Green Leap Forward?

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, Richard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ye, Qing [Shenzhen Inst. of Building Research (China); Feng, Wei [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yan, Tao [Shenzhen Inst. of Building Research (China); Mao, Hongwei [Shenzhen Inst. of Building Research (China); Li, Yutong [Shenzhen Inst. of Building Research (China); Guo, Yongcong [Shenzhen Inst. of Building Research (China); Wang, Jialiang [Shenzhen Inst. of Building Research (China)

    2013-09-01

    China is constructing new commercial buildings at an enormous rate -- roughly 2 billion square meters per year, with considerable interest and activity in green design and construction. We review the context of commercial building design and construction in China, and look at a specific project as an example of a high performance, sustainable design, the Shenzhen Institute of Building Research (IBR). The IBR building incorporates over 40 sustainable technologies and strategies, including daylighting, natural ventilation, gray-water recycling, solar-energy generation, and highly efficient Heating Ventilation and Air Conditioning (HVAC) systems. We present measured data on the performance of the building, including detailed analysis by energy end use, water use, and occupant comfort and satisfaction. Total building energy consumption in 2011 was 1151 MWh, with an Energy Use Intensity (EUI) of 63 kWh/m2 (20 kBtu/ft2), which is 61% of the mean EUI value of 103 kWh/m2 (33 kBtu/ft2) for similar buildings in the region. We also comment on the unique design process, which incorporated passive strategies throughout the building, and has led to high occupant satisfaction with the natural ventilation, daylighting, and green patio work areas. Lastly we present thoughts on how the design philosophy of the IBR building can be a guide for low-energy design in different climate regions throughout China and elsewhere.

  1. Bellanca building, Yellowknife : building envelope retrofit project

    Energy Technology Data Exchange (ETDEWEB)

    Rajewski, G. [A.D. Williams Engineering Inc., Edmonton, AB (Canada)

    2008-07-01

    The Bellanca building is a ten-story, commercial office building, located in Yellowknife, Northwest Territories. The owner was concerned about annual fuel consumption, relative to other buildings of similar size. Tenants reported cold drafts and some ice build-up had been reported in the past, on the exterior of the cladding. In addition, some water penetration had occurred during rainfall. This presentation provided background information on the Bellanca building and discussed a building envelope retrofit project. A.D. Williams was hired in late 2006 in order to provide an opinion on the present condition of the building envelope. This presentation described the site investigation and presented an interior and exterior review of the building. It also presented a thermographic survey in order to map thermal anomalies and establish trends. Following acceptance of the report on findings, one of five options was selected for further development. This included removal of existing cladding, exterior gypsum wallboard, fiberglass insulation and application of BASF Walltite CT foam, sheathing, rigid insulation, drainage plane and new cladding. The preliminary design was then presented. This paper also described the tender and award of the contract; construction phase; and substantial completion of the project. tabs, figs.

  2. Work in the area of buildings 513 - 289 - 214 - Disruption to traffic

    CERN Multimedia

    Optical Fibre Section, TS/EL

    2005-01-01

    The TS/EL group wishes to inform you that, in order to create an optical fibre access for the GEANT2 project, Route Rutherford will be closed to the public between Buildings 289 and 214 on 13 July 2005. Part of the Sophora car park will also be closed while the work is in progress (week 28: 11 - 15 July). You are requested to comply with the road signs in place. For more information, please call 160484. Optical Fibre Section, TS/EL

  3. Heat planning for fossil-fuel-free district heating areas with extensive end-use heat savings: A case study of the Copenhagen district heating area in Denmark

    International Nuclear Information System (INIS)

    Harrestrup, M.; Svendsen, S.

    2014-01-01

    The Danish government plans to make the Danish energy system to be completely free of fossil fuels by 2050 and that by 2035 the energy supply for buildings and electricity should be entirely based on renewable energy sources. To become independent from fossil fuels, it is necessary to reduce the energy consumption of the existing building stock, increase energy efficiency, and convert the present heat supply from fossil fuels to renewable energy sources. District heating is a sustainable way of providing space heating and domestic hot water to buildings in densely populated areas. This paper is a theoretical investigation of the district heating system in the Copenhagen area, in which heat conservation is related to the heat supply in buildings from an economic perspective. Supplying the existing building stock from low-temperature energy resources, e.g. geothermal heat, might lead to oversized heating plants that are too expensive to build in comparison with the potential energy savings in buildings. Long-term strategies for the existing building stock must ensure that costs are minimized and that investments in energy savings and new heating capacity are optimized and carried out at the right time. - Highlights: • We investigate how much heating consumption needs to be reduced in a district heating area. • We examine fossil-fuel-free supply vs. energy conservations in the building stock. • It is slightly cost-beneficial to invest in energy renovation from today for a societal point of view. • It is economically beneficial for district heating companies to invest in energy renovations from today. • The cost per delivered heat unit is lower when energy renovations are carried out from today

  4. Suggestions for the New Social Entrepreneurship Initiative: Focus on Building a Body of Research-Proven Programs, Shown to Produce Major Gains in Education, Poverty Reduction, Crime Prevention, and Other Areas

    Science.gov (United States)

    Coalition for Evidence-Based Policy, 2009

    2009-01-01

    This paper outlines a possible approach to implementing the Social Entrepreneurship initiative, focused on building a body of research-proven program models/strategies, and scaling them up, so as to produce major progress in education, poverty reduction, crime prevention, and other areas. The paper summarizes the rationale for this approach, then…

  5. Acoustic classification of buildings in Europe – Main characteristics of national schemes for housing, schools, hospitals and office buildings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2018-01-01

    schemes define limit values for a number of acoustic performance areas, typically airborne and impact sound insulation, service equipment noise, traffic noise and reverberation time, i.e. the same as in regulations. Comparative studies of the national acoustic classification schemes in Europe show main......Building regulations specify minimum requirements, and more than ten countries in Europe have published national acoustic classification schemes with quality classes, the main purpose being to introduce easy specification of stricter acoustic criteria than defined in regulations. The very first...... classification schemes were published in the mid 1990’es and for dwellings only. Since then, more countries have introduced such schemes, some including also other building categories like e.g. schools, hospitals and office buildings, and the first countries have made updates more times. Acoustic classification...

  6. Analysis of the build-up of semi and non volatile organic compounds on urban roads.

    Science.gov (United States)

    Mahbub, Parvez; Ayoko, Godwin A; Goonetilleke, Ashantha; Egodawatta, Prasanna

    2011-04-01

    Vehicular traffic in urban areas may adversely affect urban water quality through the build-up of traffic generated semi and non volatile organic compounds (SVOCs and NVOCs) on road surfaces. The characterisation of the build-up processes is the key to developing mitigation measures for the removal of such pollutants from urban stormwater. An in-depth analysis of the build-up of SVOCs and NVOCs was undertaken in the Gold Coast region in Australia. Principal Component Analysis (PCA) and Multicriteria Decision tools such as PROMETHEE and GAIA were employed to understand the SVOC and NVOC build-up under combined traffic scenarios of low, moderate, and high traffic in different land uses. It was found that congestion in the commercial areas and use of lubricants and motor oils in the industrial areas were the main sources of SVOCs and NVOCs on urban roads, respectively. The contribution from residential areas to the build-up of such pollutants was hardly noticeable. It was also revealed through this investigation that the target SVOCs and NVOCs were mainly attached to particulate fractions of 75-300 μm whilst the redistribution of coarse fractions due to vehicle activity mainly occurred in the >300 μm size range. Lastly, under combined traffic scenario, moderate traffic with average daily traffic ranging from 2300 to 5900 and average congestion of 0.47 were found to dominate SVOC and NVOC build-up on roads. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Energy statistics for one- and two-dwelling buildings in 2007; Energistatistik foer smaahus 2007

    Energy Technology Data Exchange (ETDEWEB)

    2009-01-15

    The survey of energy statistics in 2007 on one- and two-dwelling buildings, including agricultural one- and two-dwelling buildings, is based on a sample of 6,849 buildings. The survey was carried out as a mail survey in June 2007. The non-response rate was 37 percent. The presentation provides data on energy use, number of one- and two-dwelling buildings, and heated floor areas for the total population and for various subdivisions. The use of oil for hot water and heating of one- and two-dwelling buildings has decreased by 23 percent compared to 2006, and by 71 percent the last 5 years. The number of air heat pumps increased by 41 per cent compared to 2006 and the total number of heat pumps increased from over 500 000 to over 650 000. More than 45 percent of the one- and two-dwelling buildings are heated by electricity exclusively, including buildings heated by air heat pump. About 20 percent are heated by a combination of bio fuel and electricity and about 3 percent are heated by oil exclusively. 17,200 kWh electricity per household in one- and two-dwelling buildings heated by direct electricity exclusively and 20,300 kWh in one- and two-dwelling buildings heated by water-borne electricity exclusively or 132 kWh per square metre of heated surface area (incl. electricity for household purposes). 2.8 cubic metres of oil per household in one- and two-dwelling buildings heated by oil exclusively or 19.9 litres of oil per square metre of heated surface area. 13.5 TWh electricity for households in one- and two-dwelling buildings, including the electricity used in combinations with other types of heating, but excluding electricity for household purposes which is estimated to 10,4 TWh. 258,000 cubic metres of oil (about 2.6 TWh) for households in one- and two-dwelling buildings. This includes mixed heating. 6.6 millions cubic metres of firewood in one- and two-dwelling buildings, 975,000 cubic metres of wood chips and 461,000 tons of pellets. This amount corresponds to 11

  8. Smart buildings: Energy efficient conditioning of building occupants

    NARCIS (Netherlands)

    Zeiler, W.; Houten, van M.A.; Boxem, G.; Vehler, R.; Verhoeven, M.; Fremouw, M.

    2009-01-01

    To further optimize energy performance of buildings, intelligent building control offers new possibilities. Intelligent Software Agents (ISA) can be implemented at different levels of building automation. Individual agents for individual climate control for each user of the building in combination

  9. The capacity building of disaster management in Bojonegoro regency

    Science.gov (United States)

    Isbandono, P.; Prastyawan, A.; Gamaputra, G.

    2018-01-01

    East Java is a disaster-prone area. Head of the National Disaster Management Agency, Syamsul Maarif (2012) states that “East Java is a disaster supermarket area. Referring to Act Number 24 Year 2007 Concerning Disaster Management, disaster prevention activities are a series of activities undertaken as an effort to eliminate and/or reduce the threat of disaster (Article 1, paragraph 6).The disaster mitigation is a series of efforts to reduce disaster risk, through physical development and awareness and capacity building in the face of disaster (Article 1, paragraph 9). In 2009, the Provincial Government of East Java has been established Regional Disaster Management Agency and complete it through Local Regulation of East Java Province Number 3 Year 2010. This research was conducted in Bojonegoro. This study described the capacity building disaster handling and used descriptive research with qualitative approach. It focused on the capacity building for community preparedness in the face of. This study showed the vulnerability of regions and populations to threats flood and drought in could be physical, social and/or economical. The aims of the capacity building for the individuals and organizations are to be used effectively and efficiently in order to achieve the goals of the individuals and organizations.

  10. Highly insulating glazing in new multi-storey buildings; Hoejisolerende glaspartier i nye etageboliger

    Energy Technology Data Exchange (ETDEWEB)

    Engelund Thomsen, K.; Schmidt, H.; Aggerholm, S.

    2001-07-01

    The purpose of this report is to illustrate how highly insulating types of glazing can be used in multi-storey buildings for housing in new ways. These are energy efficient and provide good indoor climate and also satisfy requirements to high architectural quality. The project has resulted in a number of design proposal demonstrating how new types of glazing can be fitted into multi-storey buildings and how new facade expressions, space and lighting effects can be obtained by using highly insulating glass areas. The project is collaboration between the architects Boje Lundgaard and Lene Tranberg's Tegnestue, KAB Bygge og Boligadministration and Danish Building and Urban Research. Calculations of heat demand suggest that it is possible to meet the targets outlined in the Danish Government's action plan for energy. Energy 21 by using new types of highly insulating glazing in new buildings. Another 33% reduction of the heating demand is targeted in relation to existing requirements in the Danish Building Regulations 1995 (BR 95) and the Danish Building Regulations for Small Dwellings 1998 (BR-S 98). The project builds on experience gained from 'High-insulated Glass House' (Wittchen and Aggerholm, 1999) built on the housing estage Egebjerggaard in Ballerup, a suburb of Copenhagen. Examples of existing multi-storey buildings with glass facades show extensive use of glazing as early as 1830 in Spain. Walls preceding the curtain wall were built from wood and glass and rested on stone corbels at about 1 m from the load-bearing facade. The first multi-storey buildings with facades entirely made from glass date from the 1920s. The architect Le Corbusier was the first to create a building system that facilitated the construction of non-loadbearing facades. Various conditions must be especially considered at the design of facades with highly insulating glass areas, i.a. type of glass and glazing, solar shadings, frame constructions and airtightness

  11. Building perservation practice

    DEFF Research Database (Denmark)

    Pilegaard, Marie Kirstine

    Cultural Heritage sites are in the current practice, defined as everything you find on a site within a delimited selected area. Written sources and guidelines for the preservation of the cultural heritage, written by the public authorities or professionals describe them as places that tell a story...... of architects and planners is primarily to reconcile the conservation prospects with the future use of buildings and sites. They intermediary the site through selections of the narratives, and in practice the restoration or transformation projects becomes a communication of the selected story, utilized...

  12. Building Brands Together

    DEFF Research Database (Denmark)

    Ind, Nicholas; Iglesias, Oriol; Schultz, Majken

    2013-01-01

    created an online brand community. Our findings show that people participate in a community because it offers them the chance to find fulfillment, to express their creativity, and to socialize. The findings have significant implications for marketing, branding, and research professionals because......Co-creation is a rapidly emerging area of research. However, there is a lack of understanding as to how organizations use co-creation to build relationships and generate value. How does participation emerge and what outcomes does it deliver? To generate insight into the co-creation process, we...

  13. Computer-based Monitoring for Decision Support Systems and Disaster Preparedness in Buildings

    Directory of Open Access Journals (Sweden)

    Alan Vinh

    2009-04-01

    Full Text Available The operation of modern buildings can support a vast amount of static and real-time data. Static information such as building schematics is vital for security and rescue purposes. There is a need for building managers and for first responders to be notified of designated building alerts in real-time so that actions can be performed promptly. The capability to monitor building devices and to keep the first responder community updated with the latest building information during emergency situations, as well as the ability to remotely control certain building devices and processes, can be realized today. This paper describes the various challenges encountered in the research area of building interoperability and proposes methods and insights for developing a standards framework to enable communication between building information systems and first responder information systems. Having a standards framework in place will assist in the development and deployment of commercial products in support of building interoperability.

  14. Windows and Building Envelope Research and Development: A Roadmap for Emerging Technologies

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-02-01

    This Building Technologies Office (BTO) Research and Development (R&D) Roadmap identifies priority windows and building envelope R&D areas of interest. Cost and performance targets are identified for each key R&D area. The roadmap describes the technical and market challenges to be overcome, R&D activities and milestones, key stakeholders, and potential energy savings that could result if cost and performance targets are met. Methods for improving technology performance and specific strategies for reducing installed costs and mitigating any other market barriers, which would increase the likelihood of mass-market technology adoption, are identified. This roadmap is a useful resource for public and private decision makers evaluating and pursuing high-impact R&D focused on advancing next-generation energy efficient windows and building envelope technologies.

  15. ATLAS barrel toroid integration and test area in building 180

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    The ATLAS barrel toroid system consists of eight coils, each of axial length 25.3 m, assembled radially and symmetrically around the beam axis. The coils are of a flat racetrack type with two 'double-pancake' windings made of 20.5 kA aluminium-stabilized niobium-titanium superconductor. The barrel toroid is being assembled in building 180 on the Meyrin site. In the first phase of assembly, the coils are packed into their aluminium-alloy casing. These photos show the double-pancake coils from ANSALDO and the coil casings from ALSTOM. In the foreground is the tooling from COSMI used to turn over the coil casings during this first phase. In the right background is the yellow lifting gantry manufactured at JINR-Dubna, Russia which will transport the coil casings to a heating table for prestressing. Two test benches with magnetic mirror are also visible.

  16. Manhattan Project buildings and facilities at the Hanford Site: A construction history

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, M.S.

    1993-09-01

    This document thoroughly examines the role that the Hanford Engineer Works played in the Manhattan project. The historical aspects of the buildings and facilities are characterized. An in depth look at the facilities, including their functions, methods of fabrication and appearance is given for the 100 AREAS, 200 AREAS, 300 AREAS, 500, 800 and 900 AREAS, 600 AREA, 700 AREA, 1100 AREA and temporary construction structures.

  17. Manhattan Project buildings and facilities at the Hanford Site: A construction history

    International Nuclear Information System (INIS)

    Gerber, M.S.

    1993-09-01

    This document thoroughly examines the role that the Hanford Engineer Works played in the Manhattan project. The historical aspects of the buildings and facilities are characterized. An in depth look at the facilities, including their functions, methods of fabrication and appearance is given for the 100 AREAS, 200 AREAS, 300 AREAS, 500, 800 and 900 AREAS, 600 AREA, 700 AREA, 1100 AREA and temporary construction structures

  18. Simulated thermal energy demand and actual energy consumption in refurbished and non-refurbished buildings

    Science.gov (United States)

    Ilie, C. A.; Visa, I.; Duta, A.

    2016-08-01

    The EU legal frame imposes the Nearly Zero Energy Buildings (nZEB) status to any new public building starting with January 1st, 2019 and for any other new building starting with 2021. Basically, nZEB represents a Low Energy Building (LEB) that covers more than half of the energy demand by using renewable energy systems installed on or close to it. Thus, two steps have to be followed in developing nZEB: (1) reaching the LEB status through state- of-the art architectural and construction solutions (for the new buildings) or through refurbishing for the already existent buildings, followed by (2) implementing renewables; in Romania, over 65% of the energy demand in a building is directly linked to heating, domestic hot water (DHW), and - in certain areas - for cooling. Thus, effort should be directed to reduce the thermal energy demand to be further covered by using clean and affordable systems: solar- thermal systems, heat pumps, biomass, etc. or their hybrid combinations. Obviously this demand is influenced by the onsite climatic profile and by the building performance. An almost worst case scenario is approached in the paper, considering a community implemented in a mountain area, with cold and long winters and mild summers (Odorheiul Secuiesc city, Harghita county, Romania). Three representative types of buildings are analysed: multi-family households (in blocks of flats), single-family houses and administrative buildings. For the first two types, old and refurbished buildings were comparatively discussed.

  19. A Comparative Study on Seismic Analysis of Bangladesh National Building Code (BNBC) with Other Building Codes

    Science.gov (United States)

    Bari, Md. S.; Das, T.

    2013-09-01

    Tectonic framework of Bangladesh and adjoining areas indicate that Bangladesh lies well within an active seismic zone. The after effect of earthquake is more severe in an underdeveloped and a densely populated country like ours than any other developed countries. Bangladesh National Building Code (BNBC) was first established in 1993 to provide guidelines for design and construction of new structure subject to earthquake ground motions in order to minimize the risk to life for all structures. A revision of BNBC 1993 is undergoing to make this up to date with other international building codes. This paper aims at the comparison of various provisions of seismic analysis as given in building codes of different countries. This comparison will give an idea regarding where our country stands when it comes to safety against earth quake. Primarily, various seismic parameters in BNBC 2010 (draft) have been studied and compared with that of BNBC 1993. Later, both 1993 and 2010 edition of BNBC codes have been compared graphically with building codes of other countries such as National Building Code of India 2005 (NBC-India 2005), American Society of Civil Engineering 7-05 (ASCE 7-05). The base shear/weight ratios have been plotted against the height of the building. The investigation in this paper reveals that BNBC 1993 has the least base shear among all the codes. Factored Base shear values of BNBC 2010 are found to have increased significantly than that of BNBC 1993 for low rise buildings (≤20 m) around the country than its predecessor. Despite revision of the code, BNBC 2010 (draft) still suggests less base shear values when compared to the Indian and American code. Therefore, this increase in factor of safety against the earthquake imposed by the proposed BNBC 2010 code by suggesting higher values of base shear is appreciable.

  20. 29 CFR 1910.66 - Powered platforms for building maintenance.

    Science.gov (United States)

    2010-07-01

    ... the exterior building face. (4) Equipment stops. Operational areas for trackless type equipment shall... primary brakes if any suspension wire rope becomes slack. A continuous-pressure rigging-bypass switch...

  1. Building change detection via a combination of CNNs using only RGB aerial imageries

    Science.gov (United States)

    Nemoto, Keisuke; Hamaguchi, Ryuhei; Sato, Masakazu; Fujita, Aito; Imaizumi, Tomoyuki; Hikosaka, Shuhei

    2017-10-01

    Building change information extracted from remote sensing imageries is important for various applications such as urban management and marketing planning. The goal of this work is to develop a methodology for automatically capturing building changes from remote sensing imageries. Recent studies have addressed this goal by exploiting 3-D information as a proxy for building height. In contrast, because in practice it is expensive or impossible to prepare 3-D information, we do not rely on 3-D data but focus on using only RGB aerial imageries. Instead, we employ deep convolutional neural networks (CNNs) to extract effective features, and improve change detection accuracy in RGB remote sensing imageries. We consider two aspects of building change detection, building detection and subsequent change detection. Our proposed methodology was tested on several areas, which has some differences such as dominant building characteristics and varying brightness values. On all over the tested areas, the proposed method provides good results for changed objects, with recall values over 75 % with a strict overlap requirement of over 50% in intersection-over-union (IoU). When the IoU threshold was relaxed to over 10%, resulting recall values were over 81%. We conclude that use of CNNs enables accurate detection of building changes without employing 3-D information.

  2. Analysis Thermal Comfort Condition in Complex Residential Building, Case Study: Chiangmai, Thailand

    Science.gov (United States)

    Juangjandee, Warangkana

    2017-10-01

    Due to the increasing need for complex residential buildings, it appears that people migrate into the high-density urban areas because the infrastructural facilities can be easily found in the modern metropolitan areas. Such rapid growth of urbanization creates congested residential buildings obstructing solar radiation and wind flow, whereas most urban residents spend 80-90% of their time indoor. Furthermore, the buildings were mostly built with average materials and construction detail. This causes high humidity condition for tenants that could promote mould growth. This study aims to analyse thermal comfort condition in complex residential building, Thailand for finding the passive solution to improve indoor air quality and respond to local conditions. The research methodology will be in two folds: 1) surveying on case study 2) analysis for finding the passive solution of reducing humidity indoor air The result of the survey indicated that the building need to find passive solution for solving humidity problem, that can be divided into two ways which raising ventilation and indoor temperature including increasing wind-flow ventilation and adjusting thermal temperature, for example; improving building design and stack driven ventilation. For raising indoor temperature or increasing mean radiant temperature, daylight can be passive solution for complex residential design for reducing humidity and enhance illumination indoor space simultaneous.

  3. Load test of the 3701U Building roof deck and support structure

    International Nuclear Information System (INIS)

    McCoy, R.M.

    1994-01-01

    The 3701U Building roof area was load tested according to the approved load-test procedure. The 3701U Building is located in the 300 Area of the Hanford Site and has the following characteristics: Roof deck--metal decking supported by steel purlins; Roof membrane--tar and gravel; Roof slope--flat (<10 deg); and Roof elevation--height of about 12.5 ft. The 3701U Building was visited in August 1992 for a visual inspection, but because of insulation an inspection could not be performed. The building was revisited in March 1994 for the purpose of writing this test report. Because the roof could not be inspected, a test was determined to be the best way to qualify the roof for personnel access. The test procedure called for the use of a remotely-controlled robot. The conclusions are that the roof has been qualified for 500-lb total roof load and that the ''No Roof Access'' signs can be changed to ''Roof Access Restricted'' signs

  4. Danish building typologies and building stock analyses

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper

    energy savings in residential buildings. The intension with this analysis was to investigate the possible energy reduction in Denmark if the same approach had been taken for the entire Danish building stock. The report concludes that the ZeroHome initiative clearly results in energy savings, but far from...... enough to meet the government’s plan to make Danish buildings free from use of fossil fuels by 2035. This will probably require around 50 % energy savings in the Danish building stock as a whole. However, the project has proven that dedicated engagement of locals can speed up market penetration...... for energy savings in the existing Building stock....

  5. Sandia National Laboratories, Tonopah Test Range Assembly Building 9B (Building 09-54): Photographs and Written Historical and Descriptive Data

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, Rebecca A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Corporate Archives and History Program

    2017-08-01

    Assembly Building 9B (Building 09-54) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons designs. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

  6. Remote tritium-in-air sampling in reactor building at NAPS

    International Nuclear Information System (INIS)

    Mitra, S.R.; Lal Chand

    2000-01-01

    Tritium-in-air activity is an important parameter in PHW reactors from the point of view of internal exposure and heavy water escape from the system. The sampling technique in vogue in PHWRs, for measurement of tritium-in-air activity, requires collection of on the spot sample from different areas using a portable sampler. This sampler uses the bubbler method of sampling. As the areas of sampling are numerous, this technique is time consuming, laborious and can lead to significant internal exposure in areas where tritium-in-air activity is high. This technique is also error prone due to the heavy workload involved. A new scheme, in which the sampling of all the areas of reactor building is done through a sampling station, has been introduced for the first time in NAPS. This sampling station facilitates collection of samples from all the areas of reactor building, remotely and simultaneously at one place thereby reducing time, labour, exposure and error. This paper gives the details of the sampling system installed at NAPS. (author)

  7. China. Top Sector Energy. Sustainable Building. Opportunities for Dutch companies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    For China, sustainable design is necessary for controlling energy usage in crowded and constantly expanding urban areas. It is well known that China is the world's biggest construction market. Nearly half of the new buildings annually constructed worldwide are located in China by 2015. However, only about 4% of these are built according to energy efficiency standards. China's construction market will by 2020 account for 40% of the country's total energy consumption. While it contributes 15% of the world's GDP, China consumes 30% of the earth's steel and half its concrete. On top of which, buildings in China consume a third of the country's increasingly endangered water supplies. Recent research showed that almost half of the national energy consumption has been used for construction related purposes. Of existing buildings, a huge amount needs sustainable redesign and retrofitting technologies.Chinese government has recognized the urgency of widely implementing sustainable buildings. As a result, a national 3-star China National Green Building rating system has been launched in 2006. Yet the Chinese green building revolution is still in its infancy. Main problems are, amongst others, low level of regulations and standards, problematic implementations at local level, lack of awareness and transparency in related public and private sector, lack of expertise of integrated sustainable building design and construction among engineers, designers and constructors. It is also to be expected that more aggressive energy saving and environmental protection targets will be set by the 12th Five Year Plan. Promote green buildings will be one of the top priorities in China's swift urbanization process with focus on saving land, energy, water and materials. Chinese government has recognized the urgency of widely implementing sustainable buildings. Yet the Chinese green building revolution is still in its infancy. Under this framework, the

  8. China. Top Sector Energy. Sustainable Building. Opportunities for Dutch companies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    For China, sustainable design is necessary for controlling energy usage in crowded and constantly expanding urban areas. It is well known that China is the world's biggest construction market. Nearly half of the new buildings annually constructed worldwide are located in China by 2015. However, only about 4% of these are built according to energy efficiency standards. China's construction market will by 2020 account for 40% of the country's total energy consumption. While it contributes 15% of the world's GDP, China consumes 30% of the earth's steel and half its concrete. On top of which, buildings in China consume a third of the country's increasingly endangered water supplies. Recent research showed that almost half of the national energy consumption has been used for construction related purposes. Of existing buildings, a huge amount needs sustainable redesign and retrofitting technologies.Chinese government has recognized the urgency of widely implementing sustainable buildings. As a result, a national 3-star China National Green Building rating system has been launched in 2006. Yet the Chinese green building revolution is still in its infancy. Main problems are, amongst others, low level of regulations and standards, problematic implementations at local level, lack of awareness and transparency in related public and private sector, lack of expertise of integrated sustainable building design and construction among engineers, designers and constructors. It is also to be expected that more aggressive energy saving and environmental protection targets will be set by the 12th Five Year Plan. Promote green buildings will be one of the top priorities in China's swift urbanization process with focus on saving land, energy, water and materials. Chinese government has recognized the urgency of widely implementing sustainable buildings. Yet the Chinese green building revolution is still in its infancy. Under this framework, the following areas will offer business

  9. Criteria of choosing building structures for rooftop boiler rooms

    Directory of Open Access Journals (Sweden)

    Plotnikov Artyom

    2018-01-01

    Full Text Available The paper investigates parameters of noise and vibration distribution in the territory of residential area depending on the structural materials and power of independent heat supply systems. Rooftop boiler rooms are decentralized heat supply systems in buildings. Today, residential areas are strongly affected by noise and vibrations. Adverse effects are isolated by buildings materials, protective shields and floating floors. Rooftop boiler rooms located in Tyumen city were investigated within this research. Structures of rooftop boiler rooms were analyzed. Acoustic analysis results and the parameters of equivalent continuous sound level are presented. An option for improvement of rooftop boiler rooms structures is suggested. Comparison of capital investments in construction and installation activities is carried out. Conclusion on capital investments required for noise protection is made.

  10. 4th international conference in sustainability in energy and buildings

    CERN Document Server

    Höjer, Mattias; Howlett, Robert; Jain, Lakhmi

    2013-01-01

    This volume contains the proceedings of the Fourth International Conference on Sustainability in Energy and Buildings, SEB12, held in Stockholm, Sweden, and is organised by KTH Royal Institute of Technology, Stockholm, Sweden in partnership with KES International. The International Conference on Sustainability in Energy and Buildings focuses on a broad range of topics relating to sustainability in buildings but also encompassing energy sustainability more widely. Following the success of earlier events in the series, the 2012 conference includes the themes Sustainability, Energy, and Buildings and Information and Communication Technology, ICT. The SEB’12 proceedings includes invited participation and paper submissions across a broad range of renewable energy and sustainability-related topics relevant to the main theme of Sustainability in Energy and Buildings. Applicable areas include technology for renewable energy and sustainability in the built environment, optimisation and modeling techniques, informati...

  11. Exploring the relation between spatial configuration of buildings and remotely sensed temperatures

    Science.gov (United States)

    Myint, S. W.; Zheng, B.; Kaplan, S.; Huang, H.

    2013-12-01

    While the relationship between fractional cover of buildings and the UHI has been well studied, relationships of how spatial arrangements (e.g., clustered, dispersed) of buildings influence urban warming are not well understood. Since a diversity of spatial patterns can be observed under the same percentage of buildings cover, it is of great interest and importance to investigate the amount of variation in certain urban thermal feature such as surface temperature that is accounted for by the inclusion of spatial arrangement component. The various spatial arrangements of buildings cover can give rise to different urban thermal behaviors that may not be uncovered with the information of buildings fraction only, but can be captured to some extent using spatial analysis. The goal of this study is to examine how spatial arrangements of buildings influence and shape surface temperature in different urban settings. The study area selected is the Las-Vegas metropolitan area in Nevada, located in the Mojave Desert. An object-oriented approach was used to identify buildings using a Geoeye-1 image acquired on October 12, 2011. A spatial autocorrelation technique (i.e., Moran's I) that can measure spatial pattern (clustered, dispersed) was used to determine spatial configuration of buildings. A daytime temperature layer in degree Celsius, generated from Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) image, was integrated with Moran's I values of building cover and building fractions to achieve the goals set in the study. To avoid uncertainty and properly evaluate if spatial pattern of buildings has an impact on urban warming, the relation between Moran's I values and surface temperatures was observed at different levels according to their fractions (e.g., 0-0.1, 0.5-0.6, 0.9-1). There is a negative correlation exists between spatial pattern of buildings and surface temperatures implying that dispersed building arrangements elevate surface temperatures

  12. Building with Earthquakes in Mind

    Science.gov (United States)

    Mangieri, Nicholas

    2016-04-01

    Earthquakes are some of the most elusive and destructive disasters humans interact with on this planet. Engineering structures to withstand earthquake shaking is critical to ensure minimal loss of life and property. However, the majority of buildings today in non-traditional earthquake prone areas are not built to withstand this devastating force. Understanding basic earthquake engineering principles and the effect of limited resources helps students grasp the challenge that lies ahead. The solution can be found in retrofitting existing buildings with proper reinforcements and designs to deal with this deadly disaster. The students were challenged in this project to construct a basic structure, using limited resources, that could withstand a simulated tremor through the use of an earthquake shake table. Groups of students had to work together to creatively manage their resources and ideas to design the most feasible and realistic type of building. This activity provided a wealth of opportunities for the students to learn more about a type of disaster they do not experience in this part of the country. Due to the fact that most buildings in New York City were not designed to withstand earthquake shaking, the students were able to gain an appreciation for how difficult it would be to prepare every structure in the city for this type of event.

  13. Energy statistics for multi-dwelling buildings in 2008; Energistatistik foer flerbostadshus 2008

    Energy Technology Data Exchange (ETDEWEB)

    2009-09-15

    82 percent of the total heated area in multi-dwelling buildings in 2008 was heated by district heating. District heating was also used in combination with other types of heating to heat another 3 percent of the area. The percentage of area that is only heated by oil is approximately 1 percent, a slight decrease compared to 2007. Oil is also used in combination with other types of heating for approximately 1 percent of the area. The use of heating oil has decreased from 75 000 m3 in 2007 to 51 000 m3 in 2008. Natural gas and gasworks' gas consumption has decreased compared to 2007. The total water consumption was 278 millions m3. The average use was 1 698 litres per m2. Average usage of energy in 2008: 17.7 litres or (176.1 kWh) of oil per for multi-dwelling buildings in 2008, 148 kWh district heating per m2, 123 kWh electricity per m2 Total usage of energy in 2008 25.7 TWh was the total consumption of energy for heating and hot water in multi dwelling buildings in 2008

  14. Compendium of recent Building 7503 data

    Energy Technology Data Exchange (ETDEWEB)

    Shor, J.T.

    1996-02-01

    This report is a compendium of available temperature, pressure, radiation, and other data from Building 7503, pertinent to the Molten Salt Reactor Experiment (MSRE) Remediation Project. The information is divided into sections that correspond to different components, cells, or areas of the defunct MSRE. A certain amount of data is included on groundwater monitoring wells around the building and on stack radionuclide emissions. As far as possible, information is provided on the methods by which the data were collected and on their interpretation. It can be concluded from this study that no evidence exists of a spread of air or water contamination. However, certain variations and data trends of the pressures in MSRE piping lack complete explanations at present.

  15. Energy consumption in office buildings. Trends and drivers; Energibruk i kontorbygg. Trender og drivere

    Energy Technology Data Exchange (ETDEWEB)

    Langseth, Benedicte

    2013-02-01

    This report focuses on the energy usage of Norwegian office buildings. Historic data on the subject is limited, so qualitative input is gathered through interviews with property owners and contractors for energy solutions. We have looked at what affects the total area of office buildings in Norway, and realized that it more or less follows the inland gross domestic product. The report also includes cross-sectional analyses from various data sources to find what affects the specific energy usage of office buildings. The actual measured consumption deviates from estimated consumption, especially in newer buildings and especially within ventilation and cooling. Additionally, a model has been developed for projective purposes. It is well suited to test the effect of various input parameters and assumptions on the total area of office buildings and their energy consumption. Though as of yet the quality of data is not good enough to make a profound and credible estimate of total energy usage.(eb)

  16. Load test of the 277W Building high bay roof deck and support structure

    International Nuclear Information System (INIS)

    McCoy, R.M.

    1994-01-01

    The 277W Building high bay roof area was load tested according to the approved load-test procedure, WHC-SD-GN-TP-30015, Revision 1. The 277W Building is located in the 200 West Area of the Hanford Site and has the following characteristics: roof deck -- wood decking supported by 4 x 14 timber purlins; roof membrane -- tar and gravel; roof slope -- flat (<10 deg); and roof elevation -- maximum height of about 63 ft. The 227W Building was visited in March 1994 for a visual inspection. During this inspection, cracked areas were visible in the decking, but it was not possible to determine whether these cracks extended completely through the decking, which is 2-in. thick. The building was revisited in March 1994 for the purpose of writing this test report. Because the roof requires personnel access, a test was determined to be the best way to qualify the roof. The conclusions are that the roof has been qualified for 500-lb total roof load and that the ''No Roof Access'' signs can be changed to ''Roof Access Restricted'' signs

  17. Open Automated Demand Response for Small Commerical Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, June Han; Piette, Mary Ann; Koch, Ed; Hennage, Dan

    2009-05-01

    This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

  18. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  19. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  20. Building Land Information Policies

    DEFF Research Database (Denmark)

    Enemark, Stig

    2004-01-01

    The paper presents a conceptual understanding in the areas of Cadastre, Land Administration, and Land Management as a basis for building adequate land information policies. To develop this understanding the paper looks at each area as a system or an infrastructure designed for handling specific...... of measurement science, spatial information, management, and land management. (2) To establish national professional associations which accommodate a modern interdisciplinary profile. (3) To assess the capacity needs in land administration and to develop the capacity needed at societal, institutional...... and personal level.    (4) To establish appropriate institutional and organisational infrastructures to manage the integration of topographic mapping and cadastral information into a coherent land administration system for sustainable development. The paper aims to establish the basic understanding for dealing...

  1. Regulation proposal for voluntary energy efficiency labelling of commercial buildings

    International Nuclear Information System (INIS)

    Lamberts, Roberto; Goulart, Solange; Carlo, Joyce; Westphal, Fernando

    2006-01-01

    Despite of Brazil not being between the major world energy consumers, the consumption of electricity has significantly increased in the late years. The National Energy Balance of 2005, published by the Brazilian Ministry of Energy, showed an increasing of the participation of electricity in the final energy consumption of 15.7% in 2002 to 16.2% in 2004. Initially, a brief review of the initiatives taken by Brazilian Government aiming to limit and control the energy consumption in buildings is presented. Then, the regulation proposal containing the technical requirements to classify the energy efficiency level of buildings is shown. The purpose of this voluntary regulation is to provide conditions to certify the energy efficiency level of Brazilian buildings (commercial and public). It specifies the methods for energy efficiency rating of buildings and includes requirements to attend energy conservation measures in three main issues: lighting system; air conditioning system and envelope. The regulation applies to large buildings (minimum total area of 500 m 2 or when the energy demand is greater than or equal to 2,3 kV, including: Conditioned buildings; Partially conditioned buildings and Naturally ventilated buildings. (author)

  2. Building envelope regulations on thermal comfort in glass facade buildings and energy-saving potential for PMV-based comfort control

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ruey-Lung; Shu, Shiu-Ya [Department of Architecture, National United University, 1, Lien-Da, Kung-Ching Li, Miaoli, 36003 (China)

    2011-04-15

    This paper presents an investigation of the effect of building envelope regulation on thermal comfort and on the energy-saving potential for PMV-based comfort control in glass facade buildings. Occurrences and severity of overheating, based on the PMV-PPD model contained in ISO 7730, were used for the thermal comfort assessment. Parametric study simulations for an actual building with a large glass facade were carried out to predict the changes in thermal comfort levels in a space due to different glazing types, depths of overhang and glazing areas, which are the key parameters of the building envelope regulation index, named ENVLOAD, in Taiwan. The result demonstrates that the ENVLOAD has significant effect on thermal comfort. Additionally, comparative simulations between PMV-based comfort control and conventional thermostatic control were performed to investigate the changes in the energy-saving potential of a thermal comfort-controlled space due to changes of its ENVLOAD. The results demonstrate that the energy-saving potential in a PMV-based controlled space increases with low ENVLOAD conditions. (author)

  3. Decontamination and radioactivity measurement on building surfaces related to dismantling of Japan power demonstration reactor (JPDR)

    International Nuclear Information System (INIS)

    Hatakeyama, Mutsuo; Tachibana, Mitsuo; Yanagihara, Satoshi

    1997-12-01

    In the final stage of dismantling activities for decommissioning a nuclear power plant, building structures have to be demolished to release the site for unrestricted use. Since building structures are generally made from massive reinforced concrete materials, it is not a rational way to treat all concrete materials arising from its demolition as radioactive waste. Segregation of radioactive parts from building structures is therefore indispensable. The rational procedures were studied for demolition of building structures by treating arising waste as non-radioactive materials, based on the concept established by Nuclear Safety Commission, then these were implemented in the following way by the JPDR dismantling demonstration project. Areas of the JPDR facilities are categorized into two groups : possibly contaminated areas, and possibly non-contaminated areas, based on the document of the reactor operation. Radioactivity on the building surfaces was then measured to confirm that the qualitative categorization is reasonable. After that, building surfaces were decontaminated in such a way that the contaminated layers were removed with enough margin to separate radioactive parts from non-radioactive building structures. Thought it might be possible to demolish the building structures by treating arising waste as non-radioactive materials, confirmation survey for radioactivity was conducted to show that there is no artificial radioactive nuclides produced by operation in the facility. This report describes the procedures studied on measurement of radioactivity and decontamination, and the results of its implementation in the JPDR dismantling demonstration project. (author)

  4. Compliance with building energy regulations for new-build dwellings

    International Nuclear Information System (INIS)

    Pan, Wei; Garmston, Helen

    2012-01-01

    Despite increasingly stringent building energy regulations worldwide, non-compliance exists in practice. This paper examines the profile of compliance with building energy regulations for new-build dwellings. In total 404 new-build dwellings completed in the UK from 2006 to 2009 were investigated. Only a third of these dwellings were evidenced as being compliant with Building Regulations Part L (England and Wales). Such low compliance casts a serious concern over the achievability of the UK Government's target for all new-build homes to be ‘zero carbon’ from 2016. Clearly evidenced was a lack of knowledge of Part L and its compliance requirements among the supply and building control sides of new-build dwellings. The results also indicate that the compliance profile was influenced by factors including Standard Assessment Procedure (UK Government's methodology for energy efficiency) calculation submissions, learning and experience of builders and building controls with Part L, use of Part L1A checklist, the introduction of energy performance certificate (EPC), build method, dwelling type, and project size. Better compliance was associated with flats over houses and timber frame over masonry. The use of EPC and Part L1A checklist should be encouraged. Key to addressing the lack of compliance with building energy regulations is training. -- Highlights: ► There exists a lack of compliance, worldwide, with building energy regulations. ► The implementation of England and Wales building energy regulations is problematic. ► Training, learning and experience of builders and building control are critical. ► Energy performance certificate and Part L 2006 checklist helped achieve compliance. ► Flats achieved better compliance over houses; and timber frame over masonry.

  5. Setting the Stage with Geometry: Lessons & Worksheets to Build Skills in Measuring Perimeter, Area, Surface Area, and Volume. Poster/Teaching Guide. Expect the Unexpected with Math[R

    Science.gov (United States)

    Actuarial Foundation, 2013

    2013-01-01

    "Setting the Stage with Geometry" is a new math program aligned with the National Council of Teachers of Mathematics (NCTM) standards that is designed to help students in grades 6-8 build and reinforce basic geometry skills for measuring 2D and 3D shapes. Developed by The Actuarial Foundation, this program seeks to provide skill-building math…

  6. A fuzzy-based model to implement the global safety buildings index assessment for agri-food buildings

    Directory of Open Access Journals (Sweden)

    Francesco Barreca

    2014-06-01

    each of its functional areas, in terms of food hygiene and workers’ safety and welfare, as well as highlighting possible weaknesses. Though the model may be applied in either the design or the operational phase of a building, this paper focuses on its application to certain buildings already operating in a specific productive context.

  7. The building stock from perspective of change - renovation roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Airaksinen, M., Email: miimu.airaksinen@vtt.fi

    2012-06-15

    By 2050, population, society and economic structures will have changed several times. The long and short-term goals and objectives concerning our built environment are mutually contradictory. Determining objectives or creating scenarios for the future built environment is fruitless. We should approach the development of the built environment from the perspective of change and improve the flexibility and adaptability of the built environment. For the users, a built environment meeting their basic needs is part of sustainable development. Identified short-range renovation needs include eliminating damp and mould problems, improving energy and eco-efficiency, removing obstacles to mobility and adapting buildings to accommodate the needs of the elderly. Vacated areas and buildings should be recycled and offered a new life supporting a sense of community and service production. Improved energy efficiency reduces greenhouse gas emissions. Instead of renovating individual buildings, renovation of the entire area is recommended. Sustainability in construction translates into favouring recycling and renewable materials and building-specific energy systems using renewable and/or low-emission resources. It is recommended that renovations to improve energy efficiency are scheduled to coincide with other maintenance/ renovations so as to reduce costs. In renovation construction, the role of service improvement is more important than products. Improved services help to identify a solution that fulfils several customer needs, meets financial limitations and can be implemented efficiently. Companies are advised to view renovation construction as an innovative market segment entitled to its own service portfolio. Truths about new building should be discarded and new services developed based on recent study results and new technologies. (orig.)

  8. Solar energy in buildings solved by building information modeling

    Science.gov (United States)

    Chudikova, B.; Faltejsek, M.

    2018-03-01

    Building lead us to use renewable energy sources for all types of buildings. The use of solar energy is the alternatives that can be applied in a good ratio of space, price, and resultant benefits. Building Information Modelling is a modern and effective way of dealing with buildings with regard to all aspects of the life cycle. The basis is careful planning and simulation in the pre-investment phase, where it is possible to determine the effective result and influence the lifetime of the building and the cost of its operation. By simulating, analysing and insert a building model into its future environment where climate conditions and surrounding buildings play a role, it is possible to predict the usability of the solar energy and establish an ideal model. Solar systems also very affect the internal layout of buildings. Pre-investment phase analysis, with a view to future aspects, will ensure that the resulting building will be both low-energy and environmentally friendly.

  9. Building safeguards infrastructure

    International Nuclear Information System (INIS)

    Stevens, Rebecca S.; McClelland-Kerr, John

    2009-01-01

    Much has been written in recent years about the nuclear renaissance - the rebirth of nuclear power as a clean and safe source of electricity around the world. Those who question the nuclear renaissance often cite the risk of proliferation, accidents or an attack on a facility as concerns, all of which merit serious consideration. The integration of these three areas - sometimes referred to as 3S, for safety, security and safeguards - is essential to supporting the growth of nuclear power, and the infrastructure that supports them should be strengthened. The focus of this paper will be on the role safeguards plays in the 3S concept and how to support the development of the infrastructure necessary to support safeguards. The objective of this paper has been to provide a working definition of safeguards infrastructure, and to discuss xamples of how building safeguards infrastructure is presented in several models. The guidelines outlined in the milestones document provide a clear path for establishing both the safeguards and the related infrastructures needed to support the development of nuclear power. The model employed by the INSEP program of engaging with partner states on safeguards-related topics that are of current interest to the level of nuclear development in that state provides another way of approaching the concept of building safeguards infrastructure. The Next Generation Safeguards Initiative is yet another approach that underscored five principal areas for growth, and the United States commitment to working with partners to promote this growth both at home and abroad.

  10. Modelling piezoelectric energy harvesting potential in an educational building

    International Nuclear Information System (INIS)

    Li, Xiaofeng; Strezov, Vladimir

    2014-01-01

    Highlights: • Energy harvesting potential of commercialized piezoelectric tiles is analyzed. • The parameters which will affect the energy harvesting efficiency are determined. • The potential could cover 0.5% of the total energy usage of the library building. • A simplified evaluation indicator is proposed to test the considered paving area. - Abstract: In this paper, potential application of a commercial piezoelectric energy harvester in a central hub building at Macquarie University in Sydney, Australia is examined and discussed. Optimization of the piezoelectric tile deployment is presented according to the frequency of pedestrian mobility and a model is developed where 3.1% of the total floor area with the highest pedestrian mobility is paved with piezoelectric tiles. The modelling results indicate that the total annual energy harvesting potential for the proposed optimized tile pavement model is estimated at 1.1 MW h/year. This potential energy generation may be further increased to 9.9 MW h/year with a possible improvement in piezoelectric energy conversion efficiency integrated into the system. This energy harvesting potential would be sufficient to meet close to 0.5% of the annual energy needs of the building. The study confirms that locating high traffic areas is critical for optimization of the energy harvesting efficiency, as well as the orientation of the tile pavement significantly affects the total amount of the harvested energy. A Density Flow evaluation is recommended in this study to qualitatively evaluate the piezoelectric power harvesting potential of the considered area based on the number of pedestrian crossings per unit time

  11. Efficient Solutions and Cost-Optimal Analysis for Existing School Buildings

    Directory of Open Access Journals (Sweden)

    Paolo Maria Congedo

    2016-10-01

    Full Text Available The recast of the energy performance of buildings directive (EPBD describes a comparative methodological framework to promote energy efficiency and establish minimum energy performance requirements in buildings at the lowest costs. The aim of the cost-optimal methodology is to foster the achievement of nearly zero energy buildings (nZEBs, the new target for all new buildings by 2020, characterized by a high performance with a low energy requirement almost covered by renewable sources. The paper presents the results of the application of the cost-optimal methodology in two existing buildings located in the Mediterranean area. These buildings are a kindergarten and a nursery school that differ in construction period, materials and systems. Several combinations of measures have been applied to derive cost-effective efficient solutions for retrofitting. The cost-optimal level has been identified for each building and the best performing solutions have been selected considering both a financial and a macroeconomic analysis. The results illustrate the suitability of the methodology to assess cost-optimality and energy efficiency in school building refurbishment. The research shows the variants providing the most cost-effective balance between costs and energy saving. The cost-optimal solution reduces primary energy consumption by 85% and gas emissions by 82%–83% in each reference building.

  12. A Distributed Intelligent Automated Demand Response Building Management System

    Energy Technology Data Exchange (ETDEWEB)

    Auslander, David [Univ. of California, Berkeley, CA (United States); Culler, David [Univ. of California, Berkeley, CA (United States); Wright, Paul [Univ. of California, Berkeley, CA (United States); Lu, Yan [Siemens Corporate Research Inc., Princeton, NJ (United States); Piette, Mary [Univ. of California, Berkeley, CA (United States)

    2013-03-31

    The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load

  13. Environmental impact of energy standards - Perspectives for Swiss building; Umweltwirkungen von Energiestandards. Perspektiven fuer den Gebaeudepark Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Dettli, R.; Baur, M.; Philippen, D. [Econcept AG, Zuerich (Switzerland); Frischknecht, R.; Faist Emmenegger, M. [ESU-Services GmbH, Uster (Switzerland)

    2006-12-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) deals with the effects energy standards have in the environmental area. First of all, the buildings examined, system limits and reference parameters and indicators are defined. The standards examined, types of building and energy systems used are dealt with, as are energy performance figures and Swiss standards such as SIA 380/1, MuKEn, Minergie and Minergie-P. The environmental loading caused by building activities is discussed both in general as well as for various particular standards. The influence of various factors such as the use of heat pumps, the electricity mix used and buildings with oil heating is discussed. The results for new and refurbished buildings are examined and future developments in the Swiss residential buildings area and their environmental impact are discussed. A comprehensive annex completes the report.

  14. Climate leadership program: Building Africa's resilience through ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Activities include training, research, testing of climate solutions in local communities, and coaching and mentorship in the area of policy development and advocacy. Emphasis will be placed on building leadership capacity among women. This is a collaborative effort between the University of Nairobi and the Institute of ...

  15. Influence of small and medium building engineering ...

    African Journals Online (AJOL)

    This study investigated the influence of small and medium building engineering entrepreneurship for the actualization of vision 20:2020 in Kebbi State, Nigeria. The study was conducted in Birnin Kebbi, Zuru and Argungu Local Government Areas of Kebbi State. The data were obtained from both primary and secondary ...

  16. Treatment of Chlorinated Solvents in Groundwater Beneath an Occupied Building at the Young-Rainey STAR Center, Pinellas, FL

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Joe [Navarro Research and Engineering; Surovchak, Scott [Dept. of Energy (DOE), Legacy Management; Tabor, Charles [Navarro Research and Engineering

    2016-03-01

    Groundwater contamination, consisting of two dissolved-phase plumes originating from chlorinated solvent source areas, in the southeastern portion of the Young- Rainey Star Center (also known as the Pinellas County, Florida, Site) in Largo, Florida, has migrated beyond the property boundary, beneath the roadways, and beneath adjacent properties to the south and east. Groundwater contamination will persist as long as the onsite contaminant source remains. The origin of the contamination appears to be multiple long-term point sources beneath Building 100, a 4.5 ha (11 acre) building that housed manufacturing facilities during US DOE operations at the site. The site is now owned by Pinellas County, and most of the space inside the building is leased to private companies, so DOE chose not to conduct characterization or remediation through the floor of the building, instead choosing to conduct all work from outside the building. Injection of emulsified soybean oil and a microbial culture has been used at other areas of the site to accelerate naturally occurring bacterial processes that degrade groundwater contaminants to harmless compounds, and that same approach was chosen for this task. The technical approach consisted of installing horizontal wells from outside the building footprint, extending through and around the identified subsurface treatment areas, and terminating beneath the building. Two 107 m (350 ft) long wells, two 122 m (400 ft) long wells, and four 137 m (450 ft) long wells have been installed to intersect the inferred source areas and confirmed contaminant plumes beneath the building. DOE then injected emulsified vegetable oil and a microbial culture into the horizontal wells at each of several target areas beneath the building where the highest groundwater contaminant concentrations have been detected. The target areas are the northwest corner of the building between the old drum storage pad locations and monitoring well PIN12-S35B, the vicinity of

  17. Resilient design in the conservation of Johar market heritage building

    Science.gov (United States)

    Roesmanto, Totok

    2017-12-01

    Johar Market building based on Law of Repubic of Indonesia No.11 of 2010 is a heritage building. It was built in 1936 located near traditional square of Pasebaan and Aloon- Aloon was built by Dutch merchants union in 1678. Semarang based on decentralized policy by the Dutch Government in 1906 became a trading city. Rapid development of trading activities has caused the city planning policy by Semarang Government since 1970 made Aloon-Aloon become market buildings. Johar Market and market buildings in surrounding were on fire in 2015. Basing on Law No.11 of 2010 Semarang Government plans to conserve Johar Market heritage building and reconstruct Aloon-Aloon based on proposal of Roesmanto in 2016. The architect bureau assigned by the Semarang Government designed a new building in the middle of South-Johar Market to accommodate Johar merchants. This study aims to evaluate the design of new building by the architect bureau considering that since 2012 the city of Semarang including earthquake prone areas. The revitalization of Johar Market should use resilient design in order to prevent future damages to heritage buildings located nearby and new building must be spaced sufficiently against surrounding heritage buildings. This research uses descriptive qualitative method base on the field data after Johar Market burned and design planned bureau architect. The results of this study found that the distance between new building and heritage building is less wide.

  18. Retrofit of a MultiFamily Mass Masonry Building in New England

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Kerrigan, P. [Building Science Corporation, Somerville, MA (United States); Wytrykowska, H. [Building Science Corporation, Somerville, MA (United States); Van Straaten, R. [Building Science Corporation, Somerville, MA (United States)

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  19. Campus and community micro grids integration of building integrated photovoltaic renewable energy sources: Case study of Split 3 area, Croatia - part A

    Directory of Open Access Journals (Sweden)

    Gašparović Goran

    2016-01-01

    Full Text Available Micro grids interconnect loads and distributed energy resources as a single controllable entity. New installations of renewable energy sources (RES in urban areas, such as Building Integrated Photovoltaic (BIPV, provide opportunities to increase energy independence and diversify energy sources in the energy system. This paper explores the integration of RES into two case study communities in an urban agglomeration to provide optimal conditions to meet a share of the electrical loads. Energy planning case studies for decentralized generation of renewable energy are conducted in H2RES energy planning software for hourly energy balances. The results indicate that BIPV and PV in the case study communities can cover about 17% of the recorded electrical demand of both areas. On a yearly basis, there will be a 0.025 GWh surplus of PV production with a maximum value of 1.25 MWh in one hour of operation unless grid storage is used. This amounts to a total investment cost of 13.36 million EUR. The results are useful for proposing future directions for the various case study communities targeting sustainable development.

  20. Building 2000

    International Nuclear Information System (INIS)

    Den Ouden, C.; Steemers, T.C.

    1992-01-01

    This is the first volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this first rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In a second volume, a similar series of studies is presented for the building categories: office buildings, public buildings and hotels and holiday complexes. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (15 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues

  1. Building 2000

    Energy Technology Data Exchange (ETDEWEB)

    Den Ouden, C [EGM Engineering BV, Dordrecht (Netherlands); Steemers, T C [Commission of the European Communities, Brussels (Belgium)

    1992-01-01

    This is the first volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this first rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In a second volume, a similar series of studies is presented for the building categories: office buildings, public buildings and hotels and holiday complexes. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (15 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues.

  2. Valuation of Green Commercial Office Building: A Preliminary Study of Malaysian Valuers' Insight

    OpenAIRE

    Tuti Haryati Jasimin; Hishamuddin Mohd Ali

    2015-01-01

    Malaysia's green building development is gaining momentum and green buildings have become a key focus area, especially within the commercial sector with the encouragement of government legislation and policy. Due to the emerging awareness among the market players' views of the benefits associated with the ownership of green buildings in Malaysia, there is a need for valuers to incorporate consideration of sustainability into their assessments of property market value to e...

  3. BIM-Enabled Conceptual Modelling and Representation of Building Circulation

    Directory of Open Access Journals (Sweden)

    Jin Kook Lee

    2014-08-01

    Full Text Available This paper describes how a building information modelling (BIM-based approach for building circulation enables us to change the process of building design in terms of its computational representation and processes, focusing on the conceptual modelling and representation of circulation within buildings. BIM has been designed for use by several BIM authoring tools, in particular with the widely known interoperable industry foundation classes (IFCs, which follow an object-oriented data modelling methodology. Advances in BIM authoring tools, using space objects and their relations defined in an IFC's schema, have made it possible to model, visualize and analyse circulation within buildings prior to their construction. Agent-based circulation has long been an interdisciplinary topic of research across several areas, including design computing, computer science, architectural morphology, human behaviour and environmental psychology. Such conventional approaches to building circulation are centred on navigational knowledge about built environments, and represent specific circulation paths and regulations. This paper, however, places emphasis on the use of ‘space objects’ in BIM-enabled design processes rather than on circulation agents, the latter of which are not defined in the IFCs' schemas. By introducing and reviewing some associated research and projects, this paper also surveys how such a circulation representation is applicable to the analysis of building circulation-related rules.

  4. Investigation of building energy autonomy in the sahelian environment

    International Nuclear Information System (INIS)

    Coulibaly, O; Koulidiati, J; Ouedraogo, A; Kuznik, F; Baillis, D

    2012-01-01

    In this study, the energy generation of a set of photovoltaic panels is compared with the energy load of a building in order to analyse its autonomy in the sahelian environment when taking into account, the orientation, the insulation and the energy transfer optimisation of its windows. The Type 56 TRNSYS multizone building model is utilized for the energy load simulation and the Type 94 model of the same code enables the coupling of photovoltaic (PV) panels with the building. Without insulation, the PV energy generation represents 73.52 and 111.79% of the building electric energy load, respectively for poly-crystalline and mono-crystalline panels. For the same PV characteristics and when we insulate the roof and the floor, the energy generation increases to represent successively 121.09 and 184.13%. In the meantime, for building without insulation and with insulate the roof, the floor and 2 cm insulated walls, the energy consumption ratios decrease respectively from 201.13 to 105.20 kWh/m 2 /year. The investigations finally show that it is even possible to generate excess energy (positive energy building) and reduce the number and incident surface area of the PV panels if we conjugate the previous model with building passive architectural design mode (orientation, solar protection ...).

  5. Building 12-42F modification, Pantex Plant, Amarillo, Texas

    International Nuclear Information System (INIS)

    1991-02-01

    The Environment Assessment (EA) has been prepared pursuant to the implementing regulations to the National Environmental Policy Act (NEPA), which require federal agencies to assess the environmental impacts of a proposed action to determine whether that action requires the preparation of an Environmental Impact Statement (EIS) or if a Finding of No Significant Impact (FONSI) can be issued. NEPA requires that an EA provide an interdisciplinary review of the proposed action in order to identify possible preferable alternatives and to identify mitigative measures that will prevent environmental impacts. If it is determined that the proposed action will have unavoidable significant environmental impact, then as EIS shall be prepared. The proposed project is to modify Building 12-42F and entry into the Sandia Pantex Weapons Evaluation Test Laboratory. The modification's primary function is to provide additional space for testing and monitoring equipment to support the activities in the existing Building 12-42F. The modification will also facilitate the reconfiguration of the personnel offices, break room and conference area. The proposed Building 12-42F modification relates to the interiors of Buildings 12-42F and 12-42A. These buildings contain a centrifuge and associated testing and monitoring equipment. The proposed addition will encompass the existing entry into Building 12-42A. Building 12-42A will be accessed through the proposed Building 12-42F modification

  6. Effect of phase change material on the heat transfer rate of different building materials

    Science.gov (United States)

    Hasan, Mushfiq; Alam, Shahnur; Ahmed, Dewan Hasan

    2017-12-01

    Phase change material (PCM) is widely known as latent heat storage. A comprehensive study is carried out to investigate the effect of PCM on heat transfer rate of building materials. Paraffin is used as PCM along with different conventional building materials to investigate the heat transfer rate from the heated region to the cold region. PCM is placed along with the three different types of building materials like plaster which is well know building material in urban areas and wood and straw which are commonly used in rural areas for roofing as well as wall panel material and investigated the heat transfer rate. An experimental setup was constructed with number of rectangular shape aluminum detachable casing (as cavity) and placed side by side. Series of rectangular cavity filled with convent ional building materials and PCM and these were placed in between two chambers filled with water at different temperature. Building materials and PCM were placed in different cavities with different combinations and investigated the heat transfer rate. The results show that using the PCM along with other building materials can be used to maintain lower temperature at the inner wall and chamber of the cold region. Moreover, the placement or orientation of the building materials and PCM make significant contribution to heat transfer rate from the heated zone to the cold zone.

  7. Energy Efficiency, Building Productivity and the Commercial Buildings Market

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.W.

    2002-05-16

    The energy-efficiency gap literature suggests that building buyers are often short-sighted in their failure to apply life-cycle costing principles to energy efficient building technologies, with the result that under investment in these advanced technology occurs. This study examines the reasons this behavior may occur, by analyzing the pressures that market forces place on purchasers of buildings. Our basic conclusion is that the fundamental manner in which the buildings sector does business creates pressures to reduce initial capital outlays and to hedge against a variety of risks, including the ability of building owners to capture benefits from energy efficiency. Starting from the position that building buyers' willingness to pay drives choices over building attributes, we examine basic market principles, the structure of the buildings market, including the role of lenders, and policies that promote penetration of energy efficient technologies. We conclude that greater attention to buyers, and to the incentives and constraints they face, would promote a better understanding of building investment choices and contribute to better policies to promote the penetration of these technologies into markets.

  8. Areas and Volumes in Pre-Calculus

    Science.gov (United States)

    Jarrett, Joscelyn A.

    2008-01-01

    This article suggests the introduction of the concepts of areas bounded by plane curves and the volumes of solids of revolution in Pre-calculus. It builds on the basic knowledge that students bring to a pre-calculus class, derives a few more formulas, and gives examples of some problems on plane areas and the volumes of solids of revolution that…

  9. Building America Industrialized Housing Partnership (BAIHP II)

    Energy Technology Data Exchange (ETDEWEB)

    Abernethy, Bob; Chandra, Subrato; Baden, Steven; Cummings, Jim; Cummings, Jamie; Beal, David; Chasar, David; Colon, Carlos; Dutton, Wanda; Fairey, Philip; Fonorow, Ken; Gil, Camilo; Gordon, Andrew; Hoak, David; Kerr, Ryan; Peeks, Brady; Kosar, Douglas; Hewes, Tom; Kalaghchy, Safvat; Lubliner, Mike; Martin, Eric; McIlvaine, Janet; Moyer, Neil; Liguori, Sabrina; Parker, Danny; Sherwin, John; Stroer, Dennis; Thomas-Rees, Stephanie; Daniel, Danielle; McIlvaine, Janet

    2010-11-30

    This report summarizes the work conducted by the Building America Industrialized Housing Partnership (BAIHP - www.baihp.org) during the final budget period (BP5) of our contract, January 1, 2010 to November 30, 2010. Highlights from the four previous budget periods are included for context. BAIHP is led by the Florida Solar Energy Center (FSEC) of the University of Central Florida. With over 50 Industry Partners including factory and site builders, work in BP5 was performed in six tasks areas: Building America System Research Management, Documentation and Technical Support; System Performance Evaluations; Prototype House Evaluations; Initial Community Scale Evaluations; Project Closeout, Final Review of BA Communities; and Other Research Activities.

  10. Seismic analysis of a reactor building with eccentric layout

    International Nuclear Information System (INIS)

    Itoh, T.; Deng, D.Z.F.; Lui, K.

    1987-01-01

    Conventional design for a reactor building in a high seismic area has adopted an essentially concentric layout in response to fear of excessive torsional effect due to horizontal seismic load on an eccentric plant. This concentric layout requirement generally results in an inflexible arrangement of the plant facilities and thus increases the plant volume. This study is performed to investigate the effect of eccentricity on the overall seismic structural response and to provide technical information in this regard to substantiate the volume reduction of the overall power plant. The plant layout is evolved from the Bechtel standard plan of a PWR plant by integrating the reactor building and the auxiliary building into a combined building supported on a common basemat. This plant layout is optimized for volume utilization and to reduce the length of piping systems. The mass centers at various elevations of the combined building do not coincide with the rigidity center (RC) of the respective floor and the geometric center of the basemat, thus creating an eccentric response of the building in a seismic environment. Therefore, the torsional effects of the structure have to be taken into account in the seismic analysis

  11. Dynamic analysis of auxiliary buildings in nuclear power plants

    International Nuclear Information System (INIS)

    Subramanian, K.V.; Madhava Rao, A.S.; Warudkar, A.S.

    1989-01-01

    All nuclear power plants have a large number of auxiliary buildings housing various services and control systems required for the operation of the plant. Illustrative examples are turbine building, control building, service building etc. These buildings are seismically qualified as Class I or Class II structures. Usually, these auxiliary buildings are of low rise type with two or three floors and floor heights varying from five to eight meters and of framed construction in steel or concrete or a combination of both the materials. The floors are usually staggered with large cutouts and may not extend over the full area in plan. Some of the bays are often of double story height with the columns continuous over a story in order to accommodate cranes and other equipment. The structural elements supporting the roof may consist of steel roof trusses instead of beams. The seismic analysis of these structures involves the formulation of the analytical model that can simulate the physical behavior of the structure as close as possible taking into consideration the practical aspects. The criteria adopted to formulate the mathematical model has an important bearing on the evaluated dynamic characteristics and seismic response

  12. NET-ZERO ENERGY BUILDING OPERATOR TRAINING PROGRAM (NZEBOT)

    Energy Technology Data Exchange (ETDEWEB)

    Brizendine, Anthony; Byars, Nan; Sleiti, Ahmad; Gehrig, Bruce; Lu, Na

    2012-12-31

    The primary objective of the Net-Zero Energy Building Operator Training Program (NZEBOT) was to develop certificate level training programs for commercial building owners, managers and operators, principally in the areas of energy / sustainability management. The expected outcome of the project was a multi-faceted mechanism for developing the skill-based competency of building operators, owners, architects/engineers, construction professionals, tenants, brokers and other interested groups in energy efficient building technologies and best practices. The training program draws heavily on DOE supported and developed materials available in the existing literature, as well as existing, modified, and newly developed curricula from the Department of Engineering Technology & Construction Management (ETCM) at the University of North Carolina at Charlotte (UNC-Charlotte). The project goal is to develop a certificate level training curriculum for commercial energy and sustainability managers and building operators that: 1) Increases the skill-based competency of building professionals in energy efficient building technologies and best practices, and 2) Increases the workforce pool of expertise in energy management and conservation techniques. The curriculum developed in this project can subsequently be used to establish a sustainable energy training program that can contribute to the creation of new “green” job opportunities in North Carolina and throughout the Southeast region, and workforce training that leads to overall reductions in commercial building energy consumption. Three energy training / education programs were developed to achieve the stated goal, namely: 1. Building Energy/Sustainability Management (BESM) Certificate Program for Building Managers and Operators (40 hours); 2. Energy Efficient Building Technologies (EEBT) Certificate Program (16 hours); and 3. Energy Efficent Buildings (EEB) Seminar (4 hours). Training Program 1 incorporates the following

  13. Irregular Shaped Building Design Optimization with Building Information Modelling

    Directory of Open Access Journals (Sweden)

    Lee Xia Sheng

    2016-01-01

    Full Text Available This research is to recognise the function of Building Information Modelling (BIM in design optimization for irregular shaped buildings. The study focuses on a conceptual irregular shaped “twisted” building design similar to some existing sculpture-like architectures. Form and function are the two most important aspects of new buildings, which are becoming more sophisticated as parts of equally sophisticated “systems” that we are living in. Nowadays, it is common to have irregular shaped or sculpture-like buildings which are very different when compared to regular buildings. Construction industry stakeholders are facing stiff challenges in many aspects such as buildability, cost effectiveness, delivery time and facility management when dealing with irregular shaped building projects. Building Information Modelling (BIM is being utilized to enable architects, engineers and constructors to gain improved visualization for irregular shaped buildings; this has a purpose of identifying critical issues before initiating physical construction work. In this study, three variations of design options differing in rotating angle: 30 degrees, 60 degrees and 90 degrees are created to conduct quantifiable comparisons. Discussions are focused on three major aspects including structural planning, usable building space, and structural constructability. This research concludes that Building Information Modelling is instrumental in facilitating design optimization for irregular shaped building. In the process of comparing different design variations, instead of just giving “yes or no” type of response, stakeholders can now easily visualize, evaluate and decide to achieve the right balance based on their own criteria. Therefore, construction project stakeholders are empowered with superior evaluation and decision making capability.

  14. Detection of collapsed buildings from lidar data due to the 2016 Kumamoto earthquake in Japan

    Directory of Open Access Journals (Sweden)

    L. Moya

    2018-01-01

    Full Text Available The 2016 Kumamoto earthquake sequence was triggered by an Mw 6.2 event at 21:26 on 14 April. Approximately 28 h later, at 01:25 on 16 April, an Mw 7.0 event (the mainshock followed. The epicenters of both events were located near the residential area of Mashiki and affected the region nearby. Due to very strong seismic ground motion, the earthquake produced extensive damage to buildings and infrastructure. In this paper, collapsed buildings were detected using a pair of digital surface models (DSMs, taken before and after the 16 April mainshock by airborne light detection and ranging (lidar flights. Different methods were evaluated to identify collapsed buildings from the DSMs. The change in average elevation within a building footprint was found to be the most important factor. Finally, the distribution of collapsed buildings in the study area was presented, and the result was consistent with that of a building damage survey performed after the earthquake.

  15. AN APPROACH TO ALLEVIATE THE FALSE ALARM IN BUILDING CHANGE DETECTION FROM URBAN VHR IMAGE

    Directory of Open Access Journals (Sweden)

    J. Chen

    2016-06-01

    Full Text Available Building change detection from very-high-resolution (VHR urban remote sensing image frequently encounter the challenge of serious false alarm caused by different illumination or viewing angles in bi-temporal images. An approach to alleviate the false alarm in urban building change detection is proposed in this paper. Firstly, as shadows casted by urban buildings are of distinct spectral and shape feature, it adopts a supervised object-based classification technique to extract them in this paper. Secondly, on the opposite direction of sunlight illumination, a straight line is drawn along the principal orientation of building in every extracted shadow region. Starting from the straight line and moving toward the sunlight direction, a rectangular area is constructed to cover partial shadow and rooftop of each building. Thirdly, an algebra and geometry invariant based method is used to abstract the spatial topological relationship of the potential unchanged buildings from all central points of the rectangular area. Finally, based on an oriented texture curvature descriptor, an index is established to determine the actual false alarm in building change detection result. The experiment results validate that the proposed method can be used as an effective framework to alleviate the false alarm in building change detection from urban VHR image.

  16. Building on Tinto's model of engagement and persistence ...

    African Journals Online (AJOL)

    Building on Tinto's model of engagement and persistence: Experiences from the Umthombo Youth Development Foundation Scholarship Scheme. A Ross. Abstract. Background. Major inequalities in staffing levels at rural and urban hospitals contribute to poorer health outcomes in rural areas. Local and international ...

  17. The performance of atria in two school buildings

    Energy Technology Data Exchange (ETDEWEB)

    Harris, D.J. [Heriot-Watt University, Edinburgh (United Kingdom). Dept. of Building Engineering and Surveying

    1997-10-01

    Atria have become popular additions to many building types in recent years. There is a common misconception that they will automatically result in lower energy consumption, but this is not necessarily the case. Only when designed and used in an appropriate way will atria contribute to energy conservation. In this paper the performance of two school buildings, one incorporating a heat atrium, the other an unheated atrium, was studied. Comparisons between their performance were made with respect to thermal comfort, heating costs, overheating and daylighting. While heating the atrium incurred a cost penalty, it resulted in comfortable conditions in the space for a greater proportion of the time in winter, and consequently created a more useful space. In summer months overheating was likely unless an area of opening vents the equivalent of 10% or more of the floor area is provided in the atrium roof. (author)

  18. Redistribution population data across a regular spatial grid according to buildings characteristics

    Science.gov (United States)

    Calka, Beata; Bielecka, Elzbieta; Zdunkiewicz, Katarzyna

    2016-12-01

    Population data are generally provided by state census organisations at the predefined census enumeration units. However, these datasets very are often required at userdefined spatial units that differ from the census output levels. A number of population estimation techniques have been developed to address these problems. This article is one of those attempts aimed at improving county level population estimates by using spatial disaggregation models with support of buildings characteristic, derived from national topographic database, and average area of a flat. The experimental gridded population surface was created for Opatów county, sparsely populated rural region located in Central Poland. The method relies on geolocation of population counts in buildings, taking into account the building volume and structural building type and then aggregation the people total in 1 km quadrilateral grid. The overall quality of population distribution surface expressed by the mean of RMSE equals 9 persons, and the MAE equals 0.01. We also discovered that nearly 20% of total county area is unpopulated and 80% of people lived on 33% of the county territory.

  19. [Carbon footprint of buildings in the urban agglomeration of central Liaoning, China].

    Science.gov (United States)

    Shi, Yu; Yun, Ying Xia; Liu, Chong; Chu, Ya Qi

    2017-06-18

    With the development of urbanization in China, buildings consumed lots of material and energy. How to estimate carbon emission of buildings is an important scientific problem. Carbon footprint of the central Liaoning agglomeration was studied with carbon footprint approach, geographic information system (GIS) and high-resolution remote sensing (HRRS) technology. The results showed that the construction carbon footprint coefficient of central Liaoning urban agglomeration was 269.16 kg·m -2 . The approach of interpreting total building area and spatial distribution with HRRS was effective, and the accuracy was 89%. The extraction approach was critical for total carbon footprint and spatial distribution estimation. The building area and total carbon footprint of central Liaoning urban agglomeration in descending order was Shenyang, Anshan, Fushun, Liao-yang, Yingkou, Tieling and Benxi. The annual average increment of footprint from 2011 to 2013 in descending order was Shenyang, Benxi, Fushun, Anshan, Tieling, Yingkou and Liaoyang. The accurate estimation of construction carbon footprint spatial and its distribution was of significance for the planning and optimization of carbon emission reduction.

  20. A methodology for energy performance classification of residential building stock of Hamirpur

    Directory of Open Access Journals (Sweden)

    Aniket Sharma

    2017-12-01

    Full Text Available In India, there are various codes, standards, guidelines and rating systems launched to make energy intensive and large sized buildings energy efficient whereas independent residential buildings are not covered even though they exist most in numbers of total housing stock. This paper presents a case study methodology for energy performance assessment of existing residential stock of Hamirpur that can be used to develop suitable energy efficiency regulations. The paper discusses the trend of residential development in Hamirpur followed by classification based on usage, condition, predominant material use, ownership size and number of rooms, source of lighting, assets available, number of storey and plot sizes using primary and secondary data. It results in identification of predominant materials used and other characteristics in each of urban and rural area. Further cradle to site embodied energy index of various dominant building materials and their market available alternative materials is calculated from secondary literature and by calculating transportation energy. One representative existing building is selected in each of urban and rural area and their energy performance is evaluated for material embodied energy and operational energy using simulation. Further alternatives are developed based on other dominant materials in each area and evaluated for change in embodied and operational energy. This paper identifies the energy performance of representative houses for both areas and in no way advocates the preference of one type over another. The paper demonstrates a methodology by which energy performance assessment of houses shall be done and also highlights further research.

  1. Energy consumption in buildings within the services sector. 2008; Energibruk i bygninger for tjenesteytende virksomhet. 2008

    Energy Technology Data Exchange (ETDEWEB)

    Abrahamsen, Anne Sofie; Bergh, Marius

    2011-05-15

    The population and sample for this survey are based on data from The Ground Parcel, Address and Building Register (GAB) as of 1 January 2008. GAB is a computer register containing information about ground properties and addresses in Norway. Defined by type of building, around 130 000 buildings within the services sector are included in the register. Buildings with an unspecified owner, buildings smaller than 200 m2 and some special types of buildings (garages etc.) were excluded from the population, thus giving a total of just over 60 000 buildings. The gross sample was made up of 8 100 buildings, and questionnaires were sent to the landowners of these buildings. In addition to the Statistics Norway sample, data from Enova and Statsbygg, among others, was used. The net sample included about 5 000 buildings. The relatively low number of usable questionnaires in the Statistics Norway sample was related to both the quality of the data in GAB and in the reported data. The use of energy per square metre between the different types of buildings in the survey varies considerably. This is due to several factors, such as time of use of the buildings, the amount of technical equipment in the buildings, energy efficiency etc. The average for all the buildings in the survey for 2008 was 226 kWh/m2. Total energy consumption in the survey was slightly more than 5 TWh distributed over 22.5 million m2 of heated area. Electric power accounted for 83 per cent of the energy used and was by far the largest energy carrier. District heating was the second largest energy carrier with 11 per cent, while heating oil accounted for about 3 per cent. Wood and pellets made up slightly less than 2 per cent and other energy carriers totalled 0.4 per cent. Schools and kindergartens had by far the lowest use of energy, with an average of 159 kWh/m2. This is related to the relatively low time of use of the buildings and fewer technical installations using energy. On the other hand, hospitals are

  2. Classification of High-Rise Residential Building Facilities: A Descriptive Survey on 170 Housing Scheme in Klang Valley

    Directory of Open Access Journals (Sweden)

    Abd Wahab Siti Rashidah Hanum

    2016-01-01

    Full Text Available High-rise residential building is a type of housing that has multi-dwelling units built on the same land. This type of housing has become popular each year in urban area due to the increasing cost of land. There are several common facilities provided in high-rise residential building. For example playground, swimming pool, gymnasium, 24 hours security system such as CCTV, access card and so on. Thus, maintenance works of the common facilities must be well organised. The purpose of this paper is to identify the classification of facilities provided at high rise residential building. The survey was done on 170 high-rise residential schemes by using stratified random sampling technique. The scope of this research is within Klang Valley area. This area is rapidly developed with high-rise residential building. The objective of this survey is to list down all the facilities provided in each sample of the schemes. The result, there are nine classification of facilities provided for high-rise residential building.

  3. Certification of building thermographers: experiences after three courses

    Science.gov (United States)

    Kauppinen, Timo; Hekkanen, Martti; Paloniitty, Sauli; Krankka, Juha

    2006-04-01

    The certification procedure of building thermographers was started in 2003, even though thermography has been used in Finland in building survey since late 70's. There has been about a 25 years' unorganized and more or less wild period, without any generally accepted rules for interpretation, as well as how to order thermography services, how to report the results, how to do the practical work in the buildings etc. The service was provided by consultants with varied backgrounds. More operators have come into the market and building developers and contractors have begun to use thermography for quality control in new building and in renovation planning. In the year 2004 various organizations in building trade launched a pilot project to certificate building thermographers. The structure and the topics of the course were introduced in Thermosense 2005. By the end of the year 2005 the third course was completed. From the beginning of the procedure to the end of the third course about 40 persons have received a certificate. During the certification process, two guidelines have been published, as part of RT (Building Information) - files: instructions for ordering, for practical field work and for reporting of thermography survey in buildings. The guidelines also contain basics for interpretation. The interpretation is consistent with the other existing directions (building codes etc). At the turn of 2005 - 2006 a new book of building thermography was published. There is still lack of comprehensive as well as unambiguous rules for interpretation. In the paper we will present experiences on the courses, the main problems posed to the participants and findings during the last two - three years' field work. We will also introduce briefly the structure and content of the guidelines and an example how to use thermography as a tool of quality control in new building. The case studies are new one-family houses in a housing fair and exhibition area in the city of Oulu.

  4. Energy statistics for one- and two-dwelling buildings in 2008; Energistatistik foer smaahus 2008

    Energy Technology Data Exchange (ETDEWEB)

    2009-09-15

    The survey of energy statistics in 2008 on one- and two-dwelling buildings, including agricultural one- and two-dwelling buildings, is based on a sample of 6 852 buildings. The survey was carried out as a mail survey in June 2008. The non-response rate was 39 percent. The presentation provides data on energy use, number of one- and two-dwelling buildings, and heated floor areas for the total population and for various subdivisions. During the last two years the number one- and two-dwelling buildings heated solely by district heating has greatly increased. The total use of district heating has increased by 32 percent. The use of oil for hot water and heating of one- and two dwelling buildings has decreased by 21 percent compared to 2007, and by 75 percent during the last five-year period. Nearly 40 percent of one- and two-dwelling buildings are heated completely or partially with a heat pump. However, the sharp increase in the number of heat pumps during the last five-year period has nearly come to a standstill in the last two years. About 42 percent of all one- and two-dwelling buildings in Sweden are heated by electricity as the only source of heat, including houses that are heated by heat pumps. Combined heating with electricity and biomass fuel is the second most common heating method, followed by heating with solely biomass fuel. 17 100 kWh electricity per household in one- and two-dwelling buildings heated by direct electricity exclusively and 18 800 kWh in one- and two dwelling buildings heated by water-borne electricity exclusively or 130 kWh per square metre of heated surface area (incl. electricity for household purposes). 2.5 cubic metres of oil per household in one- and two-dwelling buildings heated by oil exclusively or 18.7 litres of oil per square metre of heated surface area. 12.7 TWh electricity for households in one- and two-dwelling buildings, including the electricity used in combinations with other types of heating, but excluding electricity for

  5. Application of solar roof shallow pool at individual residental buildings

    OpenAIRE

    Gavrilović Dragan J.

    2011-01-01

    The paper discusses the possibility of applying shallow roof pools of water on the basis of passive solar water capture functioning as thermal batteries and thermal "regulators" in a "hot - cold" mode with individual residential buildings. With this application, the utilization of the existing functionality of the building roof area would improve and open up the possibility of achieving better overall bio-climate individual object. By using this system, a flat roof impassable "terrace" ...

  6. Integrity Analysis of Turbine Building for the MSLB Using GOTHIC code for Wolsong NPP Unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Bong-Jin; Jin, Dong-Sik; Kim, Jong-Hyun; Han, Sang-Koo [ACT, Daejeon (Korea, Republic of); Choi, Hoon; Kho, Dong-Wook [KHNP-CRI, Daejeon (Korea, Republic of)

    2015-05-15

    A break in the piping between the steam generators and the turbine can lead to rapid loss of secondary circuit inventory. A break inside the turbine building leads to pressure differentials between different areas of the turbine building. In order to improve the environmental protection of various components within the turbine building, a wall has been erected which effectively separates the area in which these components are housed from the rest of the turbine building. Relief panels installed in the turbine building ensure that the pressure differential across the wall would be less than that required to jeopardize the wall integrity. The turbine building service wing is excluded from the scope of this analysis. It is further assumed that any doors in the heavy wall are as strong as the wall itself, with no gaps or leakage around the doors. For the full scope safety analysis of turbine building for Wolsong NPP unit 2, input decks for the various objectives, which can be read by GOTHIC 7.2a, are developed and tested for the steady state simulation. The input data files provide simplified representations of the geometric layout of the turbine building (volumes, dimensions, flow paths, doors, panels, etc.) and the performance characteristics of the various turbine building subsystems.

  7. Integrity Analysis of Turbine Building for the MSLB Using GOTHIC code for Wolsong NPP Unit 2

    International Nuclear Information System (INIS)

    Ko, Bong-Jin; Jin, Dong-Sik; Kim, Jong-Hyun; Han, Sang-Koo; Choi, Hoon; Kho, Dong-Wook

    2015-01-01

    A break in the piping between the steam generators and the turbine can lead to rapid loss of secondary circuit inventory. A break inside the turbine building leads to pressure differentials between different areas of the turbine building. In order to improve the environmental protection of various components within the turbine building, a wall has been erected which effectively separates the area in which these components are housed from the rest of the turbine building. Relief panels installed in the turbine building ensure that the pressure differential across the wall would be less than that required to jeopardize the wall integrity. The turbine building service wing is excluded from the scope of this analysis. It is further assumed that any doors in the heavy wall are as strong as the wall itself, with no gaps or leakage around the doors. For the full scope safety analysis of turbine building for Wolsong NPP unit 2, input decks for the various objectives, which can be read by GOTHIC 7.2a, are developed and tested for the steady state simulation. The input data files provide simplified representations of the geometric layout of the turbine building (volumes, dimensions, flow paths, doors, panels, etc.) and the performance characteristics of the various turbine building subsystems

  8. Using Arc GIS to analyse urban growth towards torrent risk areas (Aswan city as a case study)

    International Nuclear Information System (INIS)

    Hamdy, Omar; Zhao, Shichen; Salheen, Mohamed A; Eid, Y Y

    2014-01-01

    Areas suffering from storm water drains are considered to be the places most at risk, water torrents have an effect on urban areas and can cause a lot of damage to buildings and infrastructure. Moreover, there is dangerous situation whereby urban growth is occuring towards at-risk areas. The urban growth rate in risk areas rose up to 24.9% in 2001, and reached 48.8% in 2013. Urban growth in ''Abouelreesh'' village had been influenced by the construction of larger buildings, because most people were looking forward to live in bigger houses. We can discover the previous problem by observing the average size increase of the buildings' areas from 2001 until 2013, especially in risky areas where the average building's area had grown from 254 m2 in 2001 to 411 m2 in 2013. This Phenomenon is considered to be very important factor which attracts the urban growth towards the risky areas in spite of the danger surrounding them

  9. The role of grid-connected, building-integrated photovoltaic generation in commercial building energy and power loads in a warm and sunny climate

    International Nuclear Information System (INIS)

    Braun, P.; Ruether, R.

    2010-01-01

    For large commercial buildings, power load delivery limits are contracted with the local electricity distribution utility, and are usually fixed at one or more levels over the year, according to the seasonal building loads, and depending on the specific country regulations. Especially in warm and sunny climates, solar electricity generation using building-integrated photovoltaics (BIPV) can assist in reducing commercial building loads, offering peak-shaving (power) benefits on top of the on-site generation of electricity (energy). This on-site power delivery capability gives these consumers the possibility of renegotiating demand contracts with their distribution utility. Commercial buildings that operate during daytime quite often have an energy consumption profile that is well matched by solar radiation availability, and depending on the building's available surface areas, BIPV can generate considerable portions of the energy requirements. In this work we present the role of grid-connected BIPV in reducing the load demands of a large and urban commercial building located in a warm climate in Brazil. The building and adjacent car parking lots can accommodate a 1 MWp BIPV generator, which closely matches the building's typical maximum power demands. Based on real solar radiation data and simultaneous building electricity demands for the year 2007, simulation of the annual solar generation profile of this on-site generator showed that the 1 MWp BIPV system could account for around 30% of the total building's energy consumption. In addition to the energy benefit, maximum power demands were reduced due to a good match between midday air-conditioning cooling loads and solar radiation availability on both a daily and seasonal basis. Furthermore, we have simulated the effect of this considerably large urban-sited generator on the local distribution network load, and have shown that the 1 MWp BIPV installation can also offer considerable benefits to the local utility in

  10. A Framework for Occupancy Tracking in a Building via Structural Dynamics Sensing of Footstep Vibrations

    Directory of Open Access Journals (Sweden)

    Jeffrey D. Poston

    2017-11-01

    Full Text Available Counting the number of occupants in building areas over time—occupancy tracking—provides valuable information for responding to emergencies, optimizing thermal conditions or managing personnel. This capability is distinct from tracking individual building occupants as they move within a building, has lower complexity than conventional tracking algorithms require, and avoids privacy concerns that tracking individuals may pose. The approach proposed here is a novel combination of data analytics applied to measurements from a building’s structural dynamics sensors (e.g., accelerometers or geophones. Specifically, measurements of footstep-generated structural waves provide evidence of occupancy in a building area. These footstep vibrations can be distinguished from other vibrations, and, once identified, the footsteps can be located. These locations, in turn, form the starting point of estimating occupancy in an area. In order to provide a meaningful occupancy count, however, it is first necessary to associate discrete footsteps with individuals. The proposed framework incorporates a tractable algorithm for this association task. The proposed algorithms operate online, updating occupancy count over time as new footsteps are detected. Experiments with measurements from a public building illustrate the operation of the proposed framework. This approach offers an advantage over others based on conventional technologies by avoiding the cost of a separate sensor system devoted to occupancy tracking.

  11. Shielding effect of building to natural radiation and its influence to population dose evaluation

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Itoh, Kazuo; Yoshimura, Toshiaki.

    1980-01-01

    This work investigated the shielding effect of the building which is indispensable for the accurate evaluation of the population dose of external exposure from natural radiation. At first, the attenuation coefficients of various building materials were measured and found to agree with the calculated values within 10% errors. The shielding factors of these materials were calculated from the calculated attenuation coefficients and buildup factors. The shielding factors of the wall, window, roof and floor were calculated separately by settling the model houses and combining the shielding factors of the building materials used, and then the shielding factor of the whole building was obtained by use of the opening fraction of the wall and the fractions of the wall, roof and floor areas to the total floor area. The influence of the shielding effect of the building is well represented by the occupancy factor which is the ratio of the group doses including that shielding effect to those excluding it. The occupancy factor lies between 0.9 and 1.0 for four specified districts, Tokyo, Osaka, Ibaraki and Nagano. (author)

  12. Evaluation of Active Cooling Systems for Non-Residential Buildings

    Directory of Open Access Journals (Sweden)

    M.A. Othuman Mydin

    2014-05-01

    Full Text Available Cooling systems are an essential element in many facets of modern society including cars, computers and buildings. Cooling systems are usually divided into two types: passive and active. Passive cooling transfers heat without using any additional energy while active cooling is a type of heat transfer that uses powered devices such as fans or pumps. This paper will focus on one particular type of passive cooling: air-conditioning systems. An air-conditioning system is defined as controlled air movement, temperature, humidity and cleanliness of a building area. Air conditioning consists of cooling and heating. Therefore, the air-conditioning system should be able to add and remove heat from the area. An air-conditioning system is defined as a control or treatment of air in a confined space. The process that occurs is the air-conditioning system absorbs heat and dust while, at the same time, cleaning the air breathed into a closed space. The purpose of air-conditioning is to maintain a comfortable atmosphere for human life and to meet user requirements. In this paper, air-conditioning systems for non-residential buildings will be presented and discussed.

  13. Ten questions concerning integrating smart buildings into the smart grid

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, Thomas M.; Boudreau, Marie-Claude; Helsen, Lieve; Henze, Gregor; Mohammadpour, Javad; Noonan, Doug; Patteeuw, Dieter; Pless, Shanti; Watson, Richard T.

    2016-11-01

    Recent advances in information and communications technology (ICT) have initiated development of a smart electrical grid and smart buildings. Buildings consume a large portion of the total electricity production worldwide, and to fully develop a smart grid they must be integrated with that grid. Buildings can now be 'prosumers' on the grid (both producers and consumers), and the continued growth of distributed renewable energy generation is raising new challenges in terms of grid stability over various time scales. Buildings can contribute to grid stability by managing their overall electrical demand in response to current conditions. Facility managers must balance demand response requests by grid operators with energy needed to maintain smooth building operations. For example, maintaining thermal comfort within an occupied building requires energy and, thus an optimized solution balancing energy use with indoor environmental quality (adequate thermal comfort, lighting, etc.) is needed. Successful integration of buildings and their systems with the grid also requires interoperable data exchange. However, the adoption and integration of newer control and communication technologies into buildings can be problematic with older legacy HVAC and building control systems. Public policy and economic structures have not kept up with the technical developments that have given rise to the budding smart grid, and further developments are needed in both technical and non-technical areas.

  14. Method of decommissioning nuclear reactor building by utilizing sea water buyoancy

    International Nuclear Information System (INIS)

    Iwashima, Sumio; Ogoshi, Shigeru; Kobari, Shin-ichi.

    1989-01-01

    Upon dismantling nuclear reactor buildings, peripheral yards are excavated and channels leading to sea shore are formed. Since the outer walls of the reactor buildings are made of iron-reinforced concretes, the opening poritons are grouted with concretes to attain a tightly such closed structure that radioactive wastes, etc. in the inside are not flown out upon reactor discommisioning. Peripheral buildings at relatively low level of radiation contaminations are dismantled and withdrawn. The fundations of the nuclear reactor buildings were dug out and jacked to separate base rocks and the reactor buildings. Then, sea water is introduced into the water channels to entirely float up the buildings. A water gate is disposed in the water channel on the side of sea shore to control the level of sea water. The buildings are moved and guided to the sea shore and towed to a site optimum as a permanent storage area and then burried in that place. The operation period for the discommissioning work can greatly be shortened and the radiation dose and the amount of the wastes can be reduced. (T.M.)

  15. Active buildings: modelling physical activity and movement in office buildings. An observational study protocol.

    Science.gov (United States)

    Smith, Lee; Ucci, Marcella; Marmot, Alexi; Spinney, Richard; Laskowski, Marek; Sawyer, Alexia; Konstantatou, Marina; Hamer, Mark; Ambler, Gareth; Wardle, Jane; Fisher, Abigail

    2013-11-12

    Health benefits of regular participation in physical activity are well documented but population levels are low. Office layout, and in particular the number and location of office building destinations (eg, print and meeting rooms), may influence both walking time and characteristics of sitting time. No research to date has focused on the role that the layout of the indoor office environment plays in facilitating or inhibiting step counts and characteristics of sitting time. The primary aim of this study was to investigate associations between office layout and physical activity, as well as sitting time using objective measures. Active buildings is a unique collaboration between public health, built environment and computer science researchers. The study involves objective monitoring complemented by a larger questionnaire arm. UK office buildings will be selected based on a variety of features, including office floor area and number of occupants. Questionnaires will include items on standard demographics, well-being, physical activity behaviour and putative socioecological correlates of workplace physical activity. Based on survey responses, approximately 30 participants will be recruited from each building into the objective monitoring arm. Participants will wear accelerometers (to monitor physical activity and sitting inside and outside the office) and a novel tracking device will be placed in the office (to record participant location) for five consecutive days. Data will be analysed using regression analyses, as well as novel agent-based modelling techniques. The results of this study will be disseminated through peer-reviewed publications and scientific presentations. Ethical approval was obtained through the University College London Research Ethics Committee (Reference number 4400/001).

  16. Ethical Guidelines for Structural Interventions to Small-Scale Historic Stone Masonry Buildings.

    Science.gov (United States)

    Hurol, Yonca; Yüceer, Hülya; Başarır, Hacer

    2015-12-01

    Structural interventions to historic stone masonry buildings require that both structural and heritage values be considered simultaneously. The absence of one of these value systems in implementation can be regarded as an unethical professional action. The research objective of this article is to prepare a guideline for ensuring ethical structural interventions to small-scale stone historic masonry buildings in the conservation areas of Northern Cyprus. The methodology covers an analysis of internationally accepted conservation documents and national laws related to the conservation of historic buildings, an analysis of building codes, especially Turkish building codes, which have been used in Northern Cyprus, and an analysis of the structural interventions introduced to a significant historic building in a semi-intact state in the walled city of Famagusta. This guideline covers issues related to whether buildings are intact or ruined, the presence of earthquake risk, the types of structural decisions in an architectural conservation project, and the values to consider during the decision making phase.

  17. High Performance Homes That Use 50% Less Energy Than the DOE Building America Benchmark Building

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.

    2011-01-01

    This document describes lessons learned from designing, building, and monitoring five affordable, energy-efficient test houses in a single development in the Tennessee Valley Authority (TVA) service area. This work was done through a collaboration of Habitat for Humanity Loudon County, the US Department of Energy (DOE), TVA, and Oak Ridge National Laboratory (ORNL).The houses were designed by a team led by ORNL and were constructed by Habitat's volunteers in Lenoir City, Tennessee. ZEH5, a two-story house and the last of the five test houses to be built, provided an excellent model for conducting research on affordable high-performance houses. The impressively low energy bills for this house have generated considerable interest from builders and homeowners around the country who wanted a similar home design that could be adapted to different climates. Because a design developed without the project constraints of ZEH5 would have more appeal for the mass market, plans for two houses were developed from ZEH5: a one-story design (ZEH6) and a two-story design (ZEH7). This report focuses on ZEH6, identical to ZEH5 except that the geothermal heat pump is replaced with a SEER 16 air source unit (like that used in ZEH4). The report also contains plans for the ZEH6 house. ZEH5 and ZEH6 both use 50% less energy than the DOE Building America protocol for energyefficient buildings. ZEH5 is a 4 bedroom, 2.5 bath, 2632 ft2 house with a home energy rating system (HERS) index of 43, which qualifies it for federal energy-efficiency incentives (a HERS rating of 0 is a zero-energy house, and a conventional new house would have a HERS rating of 100). This report is intended to help builders and homeowners build similar high-performance houses. Detailed specifications for the envelope and the equipment used in ZEH5 are compared with the Building America Benchmark building, and detailed drawings, specifications, and lessons learned in the construction and analysis of data gleaned

  18. Energy consumption of electricity end uses in Malaysian historic buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kamaruzzaman, Syahrul N.; Edwards, Rodger E.; Zawawi, Emma M.A.

    2007-07-15

    Malaysia has inherited hundreds of heritage buildings from the past including those from the Indian, Chinese and Colonial eras apart from the indigenous traditional buildings. These buildings have the most unique ecstatic value from the viewpoint of architecture, culture, art, etc. Malaysian economy boom in 1980s spurred the need for more buildings especially in large cities. As a result, most of the historic buildings have been converted and transformed into commercial use. As reported by METP, Malaysian buildings energy uses are reflected by the energy consumption in the industrial and commercial sectors. Most of the buildings' energy consumption is electricity, used for running and operating the plants, lighting, lifts and escalators and other equipment in the buildings. These are amongst the factors that have resulted in the high demand for electricity in Malaysia. As outlined in the eighth Malaysia Plan, Malaysia is taking steps in conserving energy and reducing energy consumption on electricity consumption in building. This paper aims to present the breakdown of the major electricity end uses characteristics of historic buildings in Malaysia. The analysis was performed on annual data, allowing comparison with published benchmarks to give an indication of efficiency. Based on data collected a 'normalisation' calculated electricity consumption was established with the intention of improving the comparison between buildings in different climatic regions or with different occupancy patterns. This is useful for identifying where the design needed further attention and helped pinpoint problem areas within a building. It is anticipated that this study would give a good indication on the electricity consumption characteristics of historic buildings in Malaysia. (Author)

  19. Chapter 5: Buildings (EERI Earthquake Reconnaissance Team Report: M7.8 Gorkha, Nepal Earthquake on April 25, 2015 and its Aftershocks)

    Science.gov (United States)

    Kaushik, Hemant; Bevington, John; Jaiswal, Kishor; Lizundia, Bret; Shrestha, Surya

    2016-01-01

    The most common building typologies in Nepal are reinforced concrete (RC) frame buildings with masonry infill walls, unreinforced masonry (URM) bearing wall buildings, and wood frame buildings (Figure 5-1). The RC frames with masonry infills are commonly constructed in urban and semi-urban areas. Most of these buildings are three to five stories high, and most privately owned buildings are non-engineered. High rise buildings (up to 17 stories high) are also found in Kathmandu, but their number is limited. Burnt clay bricks are widely used as masonry infill walls; external walls are generally one full brick thick (~ 230 mm), and internal walls are one half brick thick. URM bearing wall buildings are an obvious choice for the population in rural areas and the outskirts of cities, primarily to limit the material expenses. Such buildings are generally two to four stories high and constructed using burnt clay brick masonry or stone masonry with cement, lime, or mud mortar. In some of the older constructions, a different mortar known as Vajra (a mix of lime and brick dust) is also observed. These buildings have either wooden or reinforced concrete flooring. A hybrid type of construction also prevails in semi-urban and rural areas, where wood frames are used in the ground story front façade, and rest of the house is made of unreinforced masonry bearing walls. Wood frame houses (generally two to three stories high) are also observed in rural areas where the material for such construction is easily available.

  20. Micro-meteorological modelling in urban areas: pollutant dispersion and radiative effects modelling

    International Nuclear Information System (INIS)

    Milliez, Maya

    2006-01-01

    Atmospheric pollution and urban climate studies require to take into account the complex processes due to heterogeneity of urban areas and the interaction with the buildings. In order to estimate the impact of buildings on flow and pollutant dispersion, detailed numerical simulations were performed over an idealized urban area, with the three-dimensional model Mercure-Saturne, modelling both concentration means and their fluctuations. To take into account atmospheric radiation in built up areas and the thermal effects of the buildings, we implemented a three-dimensional radiative model adapted to complex geometry. This model, adapted from a scheme used for thermal radiation, solves the radiative transfer equation in a semi-transparent media, using the discrete ordinate method. The new scheme was validated with idealized cases and compared to a complete case. (author) [fr

  1. Suggestions for inclulsion of radon exhalation control target in building materials radioactivity standards

    International Nuclear Information System (INIS)

    Liu Fudong; Liu Senlin; Pan Ziqiang; Zhang Yonggui

    2010-01-01

    The specific-activity and radon exhalation rate from 26 building material samples from different areas were measured with high pure germanium (HPGe) gamma spectrometer and activated carbon cartridge. It is shown that the radium content is not completely relevant to radon exhalation rate from some building material. The existing national standards on 'The Limit of Radionuclides in Building Materials' (GB 6566-2001) only present internal exposure index as control target but not for radon exhalation rate; in fact, the radon exhalation rate from building materials is closely nearly related to indoor radon concentration. So we suggest that the radon exhalation control target should be included in the national standards on 'The Limit of Radionuclides in Building Materials'. (authors)

  2. BREEAM [Building Research Establishment Environmental Assessment Method] BRE [Building Research Establishment] assessment method for buildings

    International Nuclear Information System (INIS)

    Baldwin, R.

    1994-01-01

    Buildings account for a large share of environmental impacts in their construction, use, and demolition. In western Europe, buildings account for ca 50% of primary energy use (hence CO 2 output), far outweighing the contribution of the transport and industrial sectors. Other impacts from building energy use include the use of chemicals such as chlorofluorocarbons for cooling. In the United Kingdom, the Building Research Establishment (BRE) has developed a certificate system for environmental labelling of buildings so that the performance of the building against a set of defined environmental criteria can be made visible to clients. This system thus rewards positive actions to improve the environmental performance of buildings and assists in marketing to an environmentally aware clientele. Issues included in assessments for awarding the certificate are addressed under three main headings: global issues and use of resources, local issues, and indoor issues. Global issues include ozone depletion and CO 2 emissions; local issues include public health and water conservation; and indoor issues include air quality and lighting. 8 refs., 1 tab

  3. Building 2000

    International Nuclear Information System (INIS)

    Den Ouden, C.; Steemers, T.C.

    1992-01-01

    This is the second volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this second rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In the first volume, a similar series of studies is presented for the building categories: schools, laboratories and universities, and sports and educational centres. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (11 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues

  4. Building 2000

    Energy Technology Data Exchange (ETDEWEB)

    Den Ouden, C [EGM Engineering BV, Dordrecht (Netherlands); Steemers, T C [Commission of the European Communities, Brussels (Belgium)

    1992-01-01

    This is the second volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this second rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In the first volume, a similar series of studies is presented for the building categories: schools, laboratories and universities, and sports and educational centres. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (11 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues.

  5. Vision-based building energy diagnostics and retrofit analysis using 3D thermography and building information modeling

    Science.gov (United States)

    Ham, Youngjib

    localization issues of 2D thermal image-based inspection, a new computer vision-based method is presented for automated 3D spatio-thermal modeling of building environments from images and localizing the thermal images into the 3D reconstructed scenes, which helps better characterize the as-is condition of existing buildings in 3D. By using these models, auditors can conduct virtual walk-through in buildings and explore the as-is condition of building geometry and the associated thermal conditions in 3D. Second, to address the challenges in qualitative and subjective interpretation of visual data, a new model-based method is presented to convert the 3D thermal profiles of building environments into their associated energy performance metrics. More specifically, the Energy Performance Augmented Reality (EPAR) models are formed which integrate the actual 3D spatio-thermal models ('as-is') with energy performance benchmarks ('as-designed') in 3D. In the EPAR models, the presence and location of potential energy problems in building environments are inferred based on performance deviations. The as-is thermal resistances of the building assemblies are also calculated at the level of mesh vertex in 3D. Then, based on the historical weather data reflecting energy load for space conditioning, the amount of heat transfer that can be saved by improving the as-is thermal resistances of the defective areas to the recommended level is calculated, and the equivalent energy cost for this saving is estimated. The outcome provides building practitioners with unique information that can facilitate energy efficient retrofit decision-makings. This is a major departure from offhand calculations that are based on historical cost data of industry best practices. Finally, to improve the reliability of BIM-based energy performance modeling and analysis for existing buildings, a new model-based automated method is presented to map actual thermal resistance measurements at the level of 3D vertexes to the

  6. Progressive Amalgamation of Building Clusters for Map Generalization Based on Scaling Subgroups

    Directory of Open Access Journals (Sweden)

    Xianjin He

    2018-03-01

    Full Text Available Map generalization utilizes transformation operations to derive smaller-scale maps from larger-scale maps, and is a key procedure for the modelling and understanding of geographic space. Studies to date have largely applied a fixed tolerance to aggregate clustered buildings into a single object, resulting in the loss of details that meet cartographic constraints and may be of importance for users. This study aims to develop a method that amalgamates clustered buildings gradually without significant modification of geometry, while preserving the map details as much as possible under cartographic constraints. The amalgamation process consists of three key steps. First, individual buildings are grouped into distinct clusters by using the graph-based spatial clustering application with random forest (GSCARF method. Second, building clusters are decomposed into scaling subgroups according to homogeneity with regard to the mean distance of subgroups. Thus, hierarchies of building clusters can be derived based on scaling subgroups. Finally, an amalgamation operation is progressively performed from the bottom-level subgroups to the top-level subgroups using the maximum distance of each subgroup as the amalgamating tolerance instead of using a fixed tolerance. As a consequence of this step, generalized intermediate scaling results are available, which can form the multi-scale representation of buildings. The experimental results show that the proposed method can generate amalgams with correct details, statistical area balance and orthogonal shape while satisfying cartographic constraints (e.g., minimum distance and minimum area.

  7. Issues to Be Solved for Energy Simulation of An Existing Office Building

    Directory of Open Access Journals (Sweden)

    Ki Uhn Ahn

    2016-04-01

    Full Text Available With the increasing focus on low energy buildings and the need to develop sustainable built environments, Building Energy Performance Simulation (BEPS tools have been widely used. However, many issues remain when applying BEPS tools to existing buildings. This paper presents the issues that need to be solved for the application of BEPS tools to an existing office building. The selected building is an office building with 33 stories above ground, six underground levels, and a total floor area of 91,898 m2. The issues to be discussed in this paper are as follows: (1 grey data not ready for simulation; (2 subjective assumptions and judgments on energy modeling; (3 stochastic characteristics of building performance and occupants behavior; (4 verification of model fidelity-comparison of aggregated energy; (5 verification of model fidelity-calibration by trial and error; and (6 use of simulation model for real-time energy management. This study investigates the aforementioned issues and explains the factors that should be considered to address these issues when developing a dynamic simulation model for existing buildings.

  8. Seismic assessment of Technical Area V (TA-V).

    Energy Technology Data Exchange (ETDEWEB)

    Medrano, Carlos S.

    2014-03-01

    The Technical Area V (TA-V) Seismic Assessment Report was commissioned as part of Sandia National Laboratories (SNL) Self Assessment Requirement per DOE O 414.1, Quality Assurance, for seismic impact on existing facilities at Technical Area-V (TA-V). SNL TA-V facilities are located on an existing Uniform Building Code (UBC) Seismic Zone IIB Site within the physical boundary of the Kirtland Air Force Base (KAFB). The document delineates a summary of the existing facilities with their safety-significant structure, system and components, identifies DOE Guidance, conceptual framework, past assessments and the present Geological and Seismic conditions. Building upon the past information and the evolution of the new seismic design criteria, the document discusses the potential impact of the new standards and provides recommendations based upon the current International Building Code (IBC) per DOE O 420.1B, Facility Safety and DOE G 420.1-2, Guide for the Mitigation of Natural Phenomena Hazards for DOE Nuclear Facilities and Non-Nuclear Facilities.

  9. Integrating Responsive Building Elements in Buildings

    DEFF Research Database (Denmark)

    Haase, Matthias; Amato, Alex; Heiselberg, Per

    2006-01-01

    energy strategies to develop guidelines and procedures for estimation of environmental performance of responsive building elements and integrated building concepts This paper introduces the ideas of this collaborative work and discusses its usefulness for Hong Kong and China. Special focus was put...

  10. Environment - Borrow Area for Temporary Levee

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — This data represents the location of a borrow site for construction materials used in temporary levee building during flood events. The footprint of these areas have...

  11. Global building physics

    DEFF Research Database (Denmark)

    Rode, Carsten

    2013-01-01

    High ambitions are set for the building physics performance of buildings today. No single technology can achieve fulfilment of these ambitions alone. Integrated, multi-facetted solutions and optimization are necessary. A holistic, or ‘global’, technological perspective is needed, which includes all...... aspects of the building as defined in building engineering. We live in an international society and building solutions are developed across country borders. Building physics is a global theme. The International Association of Building Physics has global appeal. This brief article reports the keynote...

  12. Global Building Physics

    DEFF Research Database (Denmark)

    Rode, Carsten

    2012-01-01

    High ambitions are set for the building physics performance of buildings today. No single technology can achieve fulfilment of these ambitions alone. Integrated, multi-facetted solutions and optimization are necessary. A holistic, or “global”, technological perspective is needed, which includes all...... aspects of the building as defined in building engineering. We live in an international society and building solutions are developed across country borders. Building physics is a global theme. The International Association of Building Physics has global appeal. The keynote lecture and this brief paper...

  13. A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery

    Directory of Open Access Journals (Sweden)

    Fasahat Ullah Siddiqui

    2016-07-01

    Full Text Available Existing automatic building extraction methods are not effective in extracting buildings which are small in size and have transparent roofs. The application of large area threshold prohibits detection of small buildings and the use of ground points in generating the building mask prevents detection of transparent buildings. In addition, the existing methods use numerous parameters to extract buildings in complex environments, e.g., hilly area and high vegetation. However, the empirical tuning of large number of parameters reduces the robustness of building extraction methods. This paper proposes a novel Gradient-based Building Extraction (GBE method to address these limitations. The proposed method transforms the Light Detection And Ranging (LiDAR height information into intensity image without interpolation of point heights and then analyses the gradient information in the image. Generally, building roof planes have a constant height change along the slope of a roof plane whereas trees have a random height change. With such an analysis, buildings of a greater range of sizes with a transparent or opaque roof can be extracted. In addition, a local colour matching approach is introduced as a post-processing stage to eliminate trees. This stage of our proposed method does not require any manual setting and all parameters are set automatically from the data. The other post processing stages including variance, point density and shadow elimination are also applied to verify the extracted buildings, where comparatively fewer empirically set parameters are used. The performance of the proposed GBE method is evaluated on two benchmark data sets by using the object and pixel based metrics (completeness, correctness and quality. Our experimental results show the effectiveness of the proposed method in eliminating trees, extracting buildings of all sizes, and extracting buildings with and without transparent roof. When compared with current state

  14. Cost Estimates for the Decontamination and Decommissioning of Eight ORNL Buildings

    International Nuclear Information System (INIS)

    Hogan, M.

    2006-01-01

    The U.S. Department of Energy's Oak Ridge National Laboratory (ORNL) contains a number of buildings that are antiquated and no longer used. These buildings historically were used for the production of atomic weapons and often remain contaminated with radioactive materials. Certain costs and risks are associated with the long-term stewardship of the buildings. One way to reduce these liabilities is to eliminate the buildings that are no longer in use and are not expected to be used in the future. Some of these buildings at ORNL are located in an area known as 'Isotope Circle'. From this area, eight buildings that are expected to be decontaminated and decommissioned (D and D) in the next five to ten years were chosen to have cost estimates completed. The specific facilities are Buildings 3030, 3031, 3118, 3032, 3033, 3033 Annex, 3034, and 3093. There are many challenges for estimating the costs to D and D buildings potentially contaminated with radionuclides. Each building is unique, has various types and levels of contamination, and (as in this case) often lacks up-to-date information. Because of these limitations, order-of- magnitude cost estimates for each of the eight ORNL buildings were completed using parametric cost modeling software known as RACER TM (Remedial Action Cost Engineering and Requirements System). This type of cost estimate is useful for screening technical concepts and is used for budgetary planning. For the eight buildings evaluated in this study, the total cost to D and D was estimated to be nearly $6 M. This value includes the direct cost of approximately $3.5 M to complete D and D and $2.5 M in cost markups. Also, assuming the actual project does not begin until the year 2010, this total cost is escalated to almost $6.7 M, which accounts for expected inflation. Although the cost estimates in this study were expected to have a wide range in accuracy, there are various factors that could impact these estimates in a negative or positive fashion

  15. Overview of Resources for Geothermal Absorption Cooling for Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gluesenkamp, Kyle R [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mehdizadeh Momen, Ayyoub [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-06-01

    This report summarizes the results of a literature review in three areas: available low-temperature/coproduced geothermal resources in the United States, energy use for space conditioning in commercial buildings, and state of the art of geothermal absorption cooling.

  16. Learning from Local Wisdom: Friction Damper in Traditional Building

    Directory of Open Access Journals (Sweden)

    Pudjisuryadi P.

    2012-01-01

    Full Text Available Indonesia is situated in the so called “Ring of Fire” where earthquake are very frequent. Despite of all the engineering effort, due to the March 28, 2005 strong earthquake (8.7 on Richter scale a lot of modern buildings in Nias collapsed, while the traditional Northern Nias house (omohada survived without any damage. Undoubtedly many other traditional buildings in other area in Indonesia have survived similar earthquake. Something in common of the traditional building are the columns which usually are not fixed on the ground, but rest on top of flat stones. In this paper some traditional building are subjected to non linear time history analysis to artificial earthquake equivalent to 500 years return period earthquake. This study shows that apparently the columns which rest on top of flat stone acts as friction damper or base isolation. The presence of sliding at the friction type support significantly reduces the internal forces in the structure.

  17. Green Construction in Building Renovation

    Directory of Open Access Journals (Sweden)

    Ksit Barbara

    2016-06-01

    Full Text Available Modern materials and construction solutions draw more and more attention to ecology and building certification. Among the criteria appearing in revitalization, an important element is bringing plants back into heavily urbanized areas. In its natural form, this is not possible to carry out everywhere, often requiring large amounts of space. Nowadays, however, there are a number of green roofs and green wall systems, allowing “greener” construction without making significant changes in the urban environment.

  18. Significance of Building Maintenance Management on Life-Span of Buildings

    Directory of Open Access Journals (Sweden)

    Md Azree Othuman Mydin

    2017-06-01

    Full Text Available The attentions and skills of maintenance are required for the construction of buildings in this twenty-first century. Because much architectural education is still focused on the one-of-a-kind assignment, encouraging the notion of personal fulfillment through leaving a mark for off-springs and obtaining a design award by means of concept drawings. Due to the reason that many building designers (architects, engineers, technicians are not encompassed in the subsequent maintenance of the building, they just regard it as other specialists’ responsibilities. In all likelihood, the building user-to-be has no formal role: the building contractors just fulfill their accountabilities to complete the building in compliance with the contract documents, not to care occupier’s needs and wants. This paper will focus on the important of building maintenance management on the life-span of buildings.

  19. Evaluating the scope for energy-efficiency improvements in the public sector: Benchmarking NHSScotland's smaller health buildings

    International Nuclear Information System (INIS)

    Murray, Joe; Pahl, O.; Burek, S.

    2008-01-01

    The National Health Service in Scotland (NHSScotland) has, in recent years, done much to reduce energy consumption in its major healthcare buildings (hospitals). On average, a reduction of 2% per year has been achieved since 2000, based on hospital buildings. However, there had been little or no attention paid to smaller premises such as health centres, clinics, dentists, etc. Such smaller healthcare buildings in Scotland constitute 29% of the total treated floor area of all NHSScotland buildings and, therefore, may contribute a similar percentage of carbon and other emissions to the environment. By concentrating on a sample of local health centres in Scotland, this paper outlines the creation of an energy benchmark target, which is part of a wider research project to investigate the environmental impacts of small healthcare buildings in Scotland and the scope for improvements. It was found that energy consumption varied widely between different centres but this variation could not be linked to building style, floor area or volume. Overall, it was found that a benchmark of 0.2 GJ/m 3 would be challenging, but realistic

  20. Technical Support Document: 50% Energy Savings for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  1. [Estimation of spur dike-affected fish habitat area].

    Science.gov (United States)

    Ray-Shyan, Wu; Yan-Ru, Chen; Yi-Liang, Ge

    2012-04-01

    Based on the HEC-RAS and River 2D modes, and taking 5% change rate of weighted usable area (WUA) as the threshold to define the spur dike- affected area of target fish species Acrossocheilus paradoxus in Fazi River in Taiwan, this paper studied the affected area of the fish habitat by spur dike, and, in combining with the references about the installations of spur dikes in Taiwan in recent 10 years, analyzed the relative importance of related affecting factors such as dike height, dike length (water block rate), average slope gradient of river way, single or double spur dike, and flow discharge. In spite of the length of the dike, the affected area in downstream was farther, and was about 2-6 times as large as that in upstream. The ratio of the affected area in downstream / upstream decreased with increasing slope gradient, but increased with increasing dike length and flow discharge. When the discharge was approximate to 10 years return periods, the ratio of the affected area would be close to a constant of 2. Building double spur dike would produce a better WUA than building single spur dike.

  2. Networks in Buildings: Which Path Forward?

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, Bruce

    2008-08-17

    To date, digital networks have principally been installed for connecting information technology devices, with more modest use in consumer electronics, security, and large building control systems. The next 20 years will see much greater deployment of networks in buildings of all types, and across all end uses. Most of these are likely to be introduced primarily for reasons other than energy efficiency, and add energy use for network interfaces and network products. Widespread networking could easily lead to increased energy use, and experience with IT and CE networks suggests this may be likely. Active engagement by energy efficiency professionals in the architecture and design of future networks could lead to their being a large and highly cost-effective tool for efficiency. However, network standards are complex and take many years to develop and negotiate so that lack of action on this in the near term may foreclose important opportunities for years or decades to come. Digital networks need to be common globally, providing another challenge to building systems and elements that are more commonly designed only for national or regional markets. Key future networks are lighting, climate control, and security/presence. This paper reviews some examples of past network designs and use and the lessons they hold for future building networks. It also highlights key needed areas for research, policy, and standards development.

  3. Building Languages

    Science.gov (United States)

    ... Glossary Contact Information Information For… Media Policy Makers Building Languages Recommend on Facebook Tweet Share Compartir Communicating ... any speech and only very loud sounds. Close × “Building Blocks” “Building Blocks” refers to the different skills ...

  4. ORGANIZATIONAL STRUCTURE FOR BUILDINGS RECONSTRUCTION OF HISTORICAL BUILDING OF ODESSA

    Directory of Open Access Journals (Sweden)

    POSTERNAK I. М.

    2016-12-01

    Full Text Available Formulation of the problem. As one of perspective forms of integration various complexes act in town-planning structure. In the course of formation of plans of social and economic development of large cities even more often there is a situation when for increase of efficiency of used resources concentration of efforts is necessary not simply, but also new progressive forms of the organization of building manufacture. Purpose. To offer the organizational structure using in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa 1820 … 1920 years under standards power efficiency and to execute researches engineering architectonics residential buildings of historical building of a city of Odessa. Conclusion. It is offered to create in the city of Odessa "the Corporate scientific and technical complex town-planning power reconstruction "CSTC T-PPR", as innovative organizational structure which uses in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa under standards power efficiency. It is considered engineering architectonics residential buildings of historical building of a city of Odessa, in particular, not looking on diverse buildings of inhabited appointment of Odessa, for them there are defining factors on which probably to make their grouping and at the same time to allocate the general lines inherent to a housing estate as a whole. It is resulted a general characteristic and classification of residential buildings of historical building of a city of Odessa ХІХ … beginnings ХХ centuries It is allocated and expanded classification of such buildings of inhabited appointment by duration of residing at them.

  5. ORGANIZATIONAL STRUCTURE FOR RECONSTRUCTION OF BUILDINGS HISTORICAL BUILDING OF ODESSA

    Directory of Open Access Journals (Sweden)

    POSTERNAK I. М.

    2017-05-01

    Full Text Available Summary. Raising of problem. As one of perspective forms of integration various complexes act in town- planning structure. In the course of formation of plans of social and economic development of large cities even more often there is a situation when for increase of efficiency of used resources concentration of efforts is necessary not simply, but also new progressive forms of the organization of building manufacture. Purpose. To offer the organizational structure using in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa 1820 … 1920 years under standards power efficiency and to execute researches engineering architectonics residential buildings of historical building of a city of Odessa. Conclusion. It is offered to create in the city of Odessa "the Corporate scientific and technical complex town-planning power reconstruction "CSTC T-PPR", as innovative organizational structure which uses in practice the saved up scientific and technical potential for reconstruction of buildings of historical building of Odessa under standards power efficiency. It is considered engineering architectonics residential buildings of historical building of a city of Odessa, in particular, not looking on diverse buildings of inhabited appointment of Odessa, for them there are defining factors on which probably to make their grouping and at the same time to allocate the general lines inherent to a housing estate as a whole. It is resulted a general characteristic and classification of residential buildings of historical building of a city of Odessa ХІХ beginnings ХХ centuries It is allocated and expanded classification of such buildings of inhabited appointment by duration of residing at them.

  6. Cost-optimal energy performance renovation measures of educational buildings in cold climate

    International Nuclear Information System (INIS)

    Niemelä, Tuomo; Kosonen, Risto; Jokisalo, Juha

    2016-01-01

    Highlights: • The proposed national nZEB target can be cost-effectively achieved in renovations. • Energy saving potential of HVAC systems is significant compared to the building envelope. • Modern renewable energy production technologies are cost-efficient and recommendable. • Improving the indoor climate conditions in deep renovations is recommendable. • Simulation-based optimization method is efficient in building performance analyzes. - Abstract: The paper discusses cost-efficient energy performance renovation measures for typical educational buildings built in the 1960s and 1970s in cold climate regions. The study analyzes the impact of different energy renovation measures on the energy efficiency and economic viability in a Finnish case study educational building located in Lappeenranta University of Technology (LUT) campus area. The main objective of the study was to determine the cost-optimal energy performance renovation measures to meet the proposed national nearly zero-energy building (nZEB) requirements, which are defined according to the primary energy consumption of buildings. The main research method of the study was simulation-based optimization (SBO) analysis, which was used to determine the cost-optimal renovation solutions. The results of the study indicate that the minimum national energy performance requirement of new educational buildings (E_p_r_i_m_a_r_y ⩽ 170 kWh/(m"2,a)) can be cost-effectively achieved in deep renovations of educational buildings. In addition, the proposed national nZEB-targets are also well achievable, while improving the indoor climate (thermal comfort and indoor air quality) conditions significantly at the same time. Cost-effective solutions included renovation of the original ventilation system, a ground source heat pump system with relatively small dimensioning power output, new energy efficient windows and a relatively large area of PV-panels for solar-based electricity production. The results and

  7. Seismic analysis of safety class 1 incinerator glovebox in building 232-Z 200 W Area

    International Nuclear Information System (INIS)

    Ocoma, E.C.

    1994-09-01

    This report documents the seismic evaluation for the existing safety class 1 incinerator glovebox in 232Z Building. The glovebox is no longer in use and most of the internal mechanical equipment have been removed. However, the insulation firebricks are still in the glovebox for proper disposal

  8. Sampling and analysis plan for the 107-N Basin recirculation building liquid/sediment

    International Nuclear Information System (INIS)

    Thompson, W.S.

    1997-02-01

    This sampling and analysis plan (SAP) defines the strategy and the field and laboratory methods that will be used to characterize the liquids and sediment within the following four 100-N buildings/areas: 1310-N valve pit area inside the Radioactive Chemical Waste Treatment Pump House (silo); 1314-N Waste Pump (Overflow) Tank at the Liquid Waste Disposal Station; 105-N Lift Station pump well and valve pit areas inside the 105-N Reactor Building; and 107-N Basin Recirculation Building. This characterization activity is being performed in support of the work scope identified in the N Reactor Deactivation Program Plan and the sampling strategy in the DQO. The characterization data will be used for comparison to decontamination and decommissioning (D and D) endpoint acceptance criteria in preparation for turnover of the above-listed facilities to the D and D project. The data will also be used for waste acceptance criteria evaluation in the selection of the appropriate disposition option for liquid and sediment currently contained in the facilities

  9. Open areas and open access

    International Nuclear Information System (INIS)

    Thorndike, A.M.

    1979-01-01

    The main objective of the two open areas in the present ISABELLE design has been to provide flexibility with respect to the size and shape of experimental equipment that would eventually be installed there. No permanent building would be installed initially. One possibility would be to enclose each experiment in a temporary structure that would provide weatherproofing and shielding; another possibility would be to erect a permanent building at a later time, when experience has made the needs clearer than they are at present. The secondary objective of the design of open areas has been to keep initial costs as low as practicable. Another objective might be added, however, which we indicate by the term ''open access.'' This note will explore this idea and some design concepts based on it. In the ISABELLE 1977 summer workshop there was considerable discussion of the importance of techniques for inserting large pieces of experimental equipment quickly and removing them with equal ease and speed. Since enclosed halls have certain restrictions in this respect, open areas may be helpful in providing this feature. If the mechanical and electrical aspects could be handled quickly, one might even attempt to reduce the time spent on bureaucratic procedures in order to expedite the introduction of new experiments and new ideas in these areas

  10. Reactor building

    International Nuclear Information System (INIS)

    Ebata, Sakae.

    1990-01-01

    At least one valve rack is disposed in a reactor building, on which pipeways to a main closure valve, valves and bypasses of turbines are placed and contained. The valve rack is fixed to the main body of the building or to a base mat. Since the reactor building is designed as class A earthquake-proofness and for maintaining the S 1 function, the valve rack can be fixed to the building main body or to the base mat. With such a constitution, the portions for maintaining the S 1 function are concentrated to the reactor building. As a result, the dispersion of structures of earthquake-proof portion corresponding to the reference earthquake vibration S 1 can be prevented. Accordingly, the conditions for the earthquake-proof design of the turbine building and the turbine/electric generator supporting rack are defined as only the class B earthquake-proof design conditions. In view of the above, the amount of building materials can be saved and the time for construction can be shortened. (I.S.)

  11. Fundamentals for a voluntary CO{sub 2} agreement and commitments in the building area - Analysis of the market, interests and acceptance; Grundlagen fuer freiwillige CO{sub 2} - Vereinbarungen und Verpflichtungen im Gebaeudebereich

    Energy Technology Data Exchange (ETDEWEB)

    Ott, W.; Kaufmann, Y.; Arend, M.

    2002-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a study made to provide answers to questions concerning the fundaments necessary for establishing an agreement on the reduction of carbon dioxide emissions in the building area. Various market segments and interest-groups were examined and their readiness to enter into voluntary agreements on the reduction of CO{sub 2} emissions assessed. Also, possible long-term changes in energy consumption and CO{sub 2} emissions were examined and the availability of data for 1990 and 2000 looked at. The results of the market analysis are presented and the refurbishment potential during the period 2000 - 2010 is assessed. Possible problems involving investment cost allocation are discussed. The report goes on to describe models for the definition of agreements in the building area and examines current hurdles that stand in the way of such agreements. Details of the mechanisms involved such as steering levies, refunds etc. are discussed and the opinions of a selection of real-estate owners and management companies on the topic are presented.

  12. Traditional boat-building and navigational techniques of southern Orissa

    Digital Repository Service at National Institute of Oceanography (India)

    Tripati, S.

    of the region. No written records on ancient boatbuilding and navigational aids of the region are available for the reconstruction of the technique of boat-building. Boats of this area have been classified into two categories, namely planked and log boats...

  13. Building integrated photovoltaics

    NARCIS (Netherlands)

    Ritzen, M.J.; Vroon, Z.A.E.P.; Geurts, C.P.W.; Reinders, Angèle; Verlinden, Pierre; Sark, Wilfried; Freundlich, Alexandre

    2017-01-01

    Photovoltaic (PV) installations can be realized in different situations and on different scales, such as at a building level. PV installations at the building level can either be added to the building envelope, which is called building added PV (BAPV), or they can be integrated into the building

  14. Methodology for the Efficient Progressive Distribution and Visualization of 3D Building Objects

    Directory of Open Access Journals (Sweden)

    Bo Mao

    2016-10-01

    Full Text Available Three-dimensional (3D, city models have been applied in a variety of fields. One of the main problems in 3D city model utilization, however, is the large volume of data. In this paper, a method is proposed to generalize the 3D building objects in 3D city models at different levels of detail, and to combine multiple Levels of Detail (LODs for a progressive distribution and visualization of the city models. First, an extended structure for multiple LODs of building objects, BuildingTree, is introduced that supports both single buildings and building groups; second, constructive solid geometry (CSG representations of buildings are created and generalized. Finally, the BuildingTree is stored in the NoSQL database MongoDB for dynamic visualization requests. The experimental results indicate that the proposed progressive method can efficiently visualize 3D city models, especially for large areas.

  15. Building Maintenance in Old Buildings Conservation Approach: An Overview of Related Problems

    Directory of Open Access Journals (Sweden)

    Brit Kayan

    2006-12-01

    Full Text Available Building maintenance in conservation of old buildings is one of the approaches applied within the built environment of Malaysia. For instance, it is realised that these old buildings contribute an important significance to our nation's priceless heritage and unique historical development. However, most of these buildings' maintenance is influenced by related problems that affect the overall building conservation approach. Therefore, these old buildings face problems which greatly affect their overall condition and performance: building structure; building appearance and aesthetic; building materials and building character. In most critical situations, there is a greater possibility that we could lose the cultural significance and heritage values of these old buildings through ignoring the related problems. This paper tries to identify the related problems, reveal the findings and discuss suitable approaches to conserving these old buildings.

  16. Daylighting and energy performance of a building for composite climate: An experimental study

    OpenAIRE

    Madhu Sudan; G.N. Tiwari

    2016-01-01

    The present study includes overall energy saving through thermal as well as daylighting for composite climate for the building known as SODHA BERS COMPLEX (SBC) situated at Varanasi, India. The building has been designed including all the passive concepts for thermal comfort as well daylighting to maximize the use of natural lighting for the occupants in day to day activities. This approach can be useful for multi-story building for rural and urban areas for both residential and commercial bu...

  17. Moroccan Coastal Management : Building Capacity to Adapt to ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Impacts from rising sea levels, coastal flooding and storm surges are becoming a challenging policy issue for planners, local authorities and stakeholders in areas such as Morocco's northeastern coast. This project will support capacity building and the development of tools and methods to underpin preparation for and ...

  18. 'Experience the future of building technologies'. High tech, low energy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    These proceedings cover the contributions presented at the CLIMA 2005 conference held in Lausanne, Switzerland. This four-day conference was sponsored by a large number of companies and organisations active in the Swiss building technologies area. Several keynote lectures were presented as were awards to students active in the building technical services area. The proceedings document the papers presented at the conference. These covered nine main topics. The first, 'Air-conditioning and ventilation' comprised 43 papers on the indoor environment, 15 on room air distribution, 4 on hygiene, 11 on alternative cooling methods, 8 on air-flow, 2 on air-cleaning and filters, 6 on refurbishment and even one concerning air-flow predictions in Egyptian tombs. The second topic, 'Heating', comprised 13 contributions on low-temperature heating and heat pumps, 7 on distributed energy systems, 4 on district heating, 7 on solar heating systems and 3 miscellaneous items. 'Design methods' were examined as a third topic with 11 contributions on building-simulation tools and 26 on computer-based methods for design, construction and operation. In the fourth section, 'Refrigeration', papers were presented on new working fluids (3 contributions), modernisation (5) along with 4 miscellaneous papers. 'Policies, standards and building-codes' were examined in four categories: Implementation of the European Energy Performance Directive with 8 contributions, life-cycle costs with 2 papers, energy conservation with 15 contributions and 2 contributions in the miscellaneous category. 'Domestic water systems and sanitary technology', the sixth section, includes 3 contributions on water conservation. Section 7, 'Building automation, security and control' includes a section on information and communication systems (3 contributions) and 6 various papers. Section 8, 'Building physics and HVAC' includes 8 contributions on double-skin and high-tech building envelopes, 7 on moisture control, and one on

  19. Analysis of conditions favourable for small vertical axis wind turbines between building passages in urban areas of Sweden

    Science.gov (United States)

    Awan, Muhammad Rizwan; Riaz, Fahid; Nabi, Zahid

    2017-05-01

    This paper presents the analysis of installing the vertical axis wind turbines between the building passages on an island in Stockholm, Sweden. Based on the idea of wind speed amplification due to the venture effect in passages, practical measurements were carried out to study the wind profile for a range of passage widths in parallel building passages. Highest increment in wind speed was observed in building passages located on the periphery of sland as wind enters from free field. Wind mapping was performed in the island to choose the most favourable location to install the vertical axis wind turbines (VAWT). Using the annual wind speed data for location and measured amplification factor, energy potential of the street was calculated. This analysis verified that small vertical axis wind turbines can be installed in the passage centre line provided that enough space is provided for traffic and passengers.

  20. Surface moisture estimation in urban areas

    Science.gov (United States)

    Jiang, Yitong

    Surface moisture is an important parameter because it modifies urban microclimate and surface layer meteorology. The primary objectives of this paper are: 1) to analyze the impact of surface roughness from buildings on surface moisture in urban areas; and 2) to quantify the impact of surface roughness resulting from urban trees on surface moisture. To achieve the objectives, two hypotheses were tested: 1) the distribution of surface moisture is associated with the structural complexity of buildings in urban areas; and 2) The distribution and change of surface moisture is associated with the distribution and vigor of urban trees. The study area is Indianapolis, Indiana, USA. In the part of the morphology of urban trees, Warren Township was selected due to the limitation of tree inventory data. To test the hypotheses, the research design was made to extract the aerodynamic parameters, such as frontal areas, roughness length and displacement height of buildings and trees from Terrestrial and Airborne LiDAR data, then to input the aerodynamic parameters into the urban surface energy balance model. The methodology was developed for comparing the impact of aerodynamic parameters from LiDAR data with the parameters that were derived empirically from land use and land cover data. The analytical procedures are discussed below: 1) to capture the spatial and temporal variation of surface moisture, daily and hourly Land Surface Temperature (LST) were downscaled from 4 km to 1 km, and 960 m to 30 m, respectively, by regression between LST and various components that impact LST; 2) to estimate surface moisture, namely soil moisture and evapotranspiration (ET), land surfaces were classified into soil, vegetation, and impervious surfaces, using Linear Spectral Mixture Analysis (LSMA); 3) aerodynamic parameters of buildings and trees were extracted from Airborne and Terrestrial LiDAR data; 4) the Temperature-Vegetation-Index (TVX) method, and the Two-Source-Energy-Balance (TSEB

  1. Final report of the decontamination and decommission of Building 31 at the Grand Junction Projects Office Facility

    International Nuclear Information System (INIS)

    Krabacher, J.E.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the domestic uranium procurement program funded by the U.S. Atomic Energy Commission. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also was the remedial action contractor. Radiological contamination was identified in Building 31 and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This area was addressed in the summary final report of the remediation of the exterior areas of the GJPO facility. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building

  2. ImBuild: Impact of building energy efficiency programs

    Energy Technology Data Exchange (ETDEWEB)

    Scott, M.J.; Hostick, D.J.; Belzer, D.B.

    1998-04-01

    As part of measuring the impact of government programs on improving the energy efficiency of the Nation`s building stock, the Department of Energy Office of Building Technology, State and Community Programs (BTS) is interested in assessing the economic impacts of its portfolio of programs, specifically the potential impact on national employment and income. The special-purpose version of the IMPLAN model used in this study is called ImBuild. In comparison with simple economic multiplier approaches, such as Department of Commerce RIMS 2 system, ImBuild allows for more complete and automated analysis of the economic impacts of energy efficiency investments in buildings. ImBuild is also easier to use than existing macroeconomic simulation models. The authors conducted an analysis of three sample BTS energy programs: the residential generator-absorber heat exchange gas heat pump (GAX heat pump), the low power sulfur lamp (LPSL) in residential and commercial applications, and the Building America program. The GAX heat pump would address the market for the high-efficiency residential combined heating and cooling systems. The LPSL would replace some highly efficient fluorescent commercial lighting. Building America seeks to improve the energy efficiency of new factory-built, modular, manufactured, and small-volume, site-built homes through use of systems engineering concepts and early incorporation of new products and processes, and by increasing the demand for more energy-efficient homes. The authors analyze a scenario for market penetration of each of these technologies devised for BTS programs reported in the BTS GPRA Metrics Estimates, FY99 Budget Request, December 19, 1997. 46 figs., 4 tabs.

  3. Urban Imperviousness Effects on Summer Surface Temperatures Nearby Residential Buildings in Different Urban Zones of Parma

    Directory of Open Access Journals (Sweden)

    Marco Morabito

    2017-12-01

    Full Text Available Rapid and unplanned urban growth is responsible for the continuous conversion of green or generally natural spaces into artificial surfaces. The high degree of imperviousness modifies the urban microclimate and no studies have quantified its influence on the surface temperature (ST nearby residential building. This topic represents the aim of this study carried out during summer in different urban zones (densely urbanized or park/rural areas of Parma (Northern Italy. Daytime and nighttime ASTER images, the local urban cartography and the Italian imperviousness databases were used. A reproducible/replicable framework was implemented named “Building Thermal Functional Area” (BTFA useful to lead building-proxy thermal analyses by using remote sensing data. For each residential building (n = 8898, the BTFA was assessed and the correspondent ASTER-LST value (ST_BTFA and the imperviousness density were calculated. Both daytime and nighttime ST_BTFA significantly (p < 0.001 increased when high levels of imperviousness density surrounded the residential buildings. These relationships were mostly consistent during daytime and in densely urbanized areas. ST_BTFA differences between urban and park/rural areas were higher during nighttime (above 1 °C than daytime (about 0.5 °C. These results could help to identify “urban thermal Hot-Spots” that would benefit most from mitigation actions.

  4. Oblique Aerial Photography Tool for Building Inspection and Damage Assessment

    Science.gov (United States)

    Murtiyoso, A.; Remondino, F.; Rupnik, E.; Nex, F.; Grussenmeyer, P.

    2014-11-01

    Aerial photography has a long history of being employed for mapping purposes due to some of its main advantages, including large area imaging from above and minimization of field work. Since few years multi-camera aerial systems are becoming a practical sensor technology across a growing geospatial market, as complementary to the traditional vertical views. Multi-camera aerial systems capture not only the conventional nadir views, but also tilted images at the same time. In this paper, a particular use of such imagery in the field of building inspection as well as disaster assessment is addressed. The main idea is to inspect a building from four cardinal directions by using monoplotting functionalities. The developed application allows to measure building height and distances and to digitize man-made structures, creating 3D surfaces and building models. The realized GUI is capable of identifying a building from several oblique points of views, as well as calculates the approximate height of buildings, ground distances and basic vectorization. The geometric accuracy of the results remains a function of several parameters, namely image resolution, quality of available parameters (DEM, calibration and orientation values), user expertise and measuring capability.

  5. Solar building

    OpenAIRE

    Zhang, Luxin

    2014-01-01

    In my thesis I describe the utilization of solar energy and solar energy with building integration. In introduction it is also mentioned how the solar building works, trying to make more people understand and accept the solar building. The thesis introduces different types of solar heat collectors. I compared the difference two operation modes of solar water heating system and created examples of solar water system selection. I also introduced other solar building applications. It is conv...

  6. Building envelope

    CSIR Research Space (South Africa)

    Gibberd, Jeremy T

    2009-01-01

    Full Text Available for use in the building. This is done through photovoltaic and solar water heating panels and wind turbines. Ideally these are integrated in the design of the building envelope to improve the aesthetic quality of the building and minimise material... are naturally ventilated. Renewable energy The building envelope includes renewable energy generation such as photovoltaics, wind turbines and solar water heaters and 10% of the building’s energy requirements are generated from these sources. Views All...

  7. Challenges in Commercial Buildings | Buildings | NREL

    Science.gov (United States)

    systems Assessing the energy and economic impacts of various technologies, giving priority to those that standardized language for commercial building energy audit data that can be used by software developers to exchange data between audit tools, and can be required by building owners and audit program managers to

  8. Converter Compressor Building, SWMU 089, Hot Spot Areas 1, 2, and 5 Operations, Maintenance, and Monitoring Report, Kennedy Space Center, Florida

    Science.gov (United States)

    Wilson, Deborah M.

    2015-01-01

    This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from operation of the air sparging (AS) interim measure (IM) for Hot Spot (HS) Areas 1, 2, and 5 at the Converter Compressor Building (CCB) located at Kennedy Space Center (KSC), Florida. The objective of the IM at CCB HS Areas 1, 2, and 5 is to decrease concentrations of volatile organic compounds (VOCs) in groundwater in the treatment zones via AS to levels that will enable a transition to a monitored natural attenuation (MNA) phase. This OMMR presents system operations and maintenance (O&M) information and performance monitoring results since full-scale O&M began in June 2014 (2 months after initial system startup in April 2014), including quarterly performance monitoring events in July and October 2014 and January and May 2015. Based on the results to date, the AS system is operating as designed and is meeting the performance criteria and IM objective. The performance monitoring network is adequately constructed for assessment of IM performance at CCB HS Areas 1, 2, and 5. At the March 2014 KSC Remediation Team (KSCRT) Meeting, team consensus was reached for the design prepared for expansion of the system to treat the HS 4 area, and at the November 2014 KSCRT Meeting, team consensus was reached that HS 3 was adequately delineated horizontally and vertically and for selection of AS for the remedial approach for HS 3. At the July 2015 KSCRT meeting, team consensus was reached to continue IM operations in all zones until HSs 3 and 4 is operational, once HS 3 and 4 zones are operational discontinue operations in HS 1, 2, and 5 zones where concentrations are less than GCTLs to observe whether rebounding conditions occur. Team consensus was also reached to continue quarterly performance monitoring to determine whether operational zones achieve GCTLs and to continue annual IGWM of CCB-MW0012, CCBMW0013, and CCB-MW0056, located south of the treatment area. The

  9. 2020 Leadership Agenda for Existing Commercial and Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Burr, Andrew [Dept. of Energy (DOE), Washington DC (United States). Office of Energy Efficiency and Renewable Energy; Goldthwaite, Carolyn Sarno [Northeast Energy Efficiency Partnerships (NEEP), Boston, MA (United States). High Performance Buildings; Coffman, Eric [Montgomery County Dept. of General Services, Rockville, MD (United States). Office of Energy and Sustainability

    2016-01-21

    Leadership by state and local governments is critical to unlock national energy efficiency opportunities and deliver the benefits of efficiency to all Americans. But related to building energy efficiency, what will it mean to be a public sector leader over the next several years? What are the energy efficiency solutions that cities, counties, and states are implementing today that will make their communities more affordable, livable, healthy, and economically competitive? The SEE Action Network 2020 Leadership Agenda for Existing Commercial and Multifamily Buildings establishes a benchmark for state and local government leadership on improving the energy efficiency of buildings and seeks two-way collaboration among state, local, and federal officials. It defines a suite of innovative, yet practical policies and programs for policymakers to consider implementing by 2020, focusing on six important areas.

  10. Building energy analysis tool

    Science.gov (United States)

    Brackney, Larry; Parker, Andrew; Long, Nicholas; Metzger, Ian; Dean, Jesse; Lisell, Lars

    2016-04-12

    A building energy analysis system includes a building component library configured to store a plurality of building components, a modeling tool configured to access the building component library and create a building model of a building under analysis using building spatial data and using selected building components of the plurality of building components stored in the building component library, a building analysis engine configured to operate the building model and generate a baseline energy model of the building under analysis and further configured to apply one or more energy conservation measures to the baseline energy model in order to generate one or more corresponding optimized energy models, and a recommendation tool configured to assess the one or more optimized energy models against the baseline energy model and generate recommendations for substitute building components or modifications.

  11. Solar envelope concepts: moderate density building applications. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Knowles, R.L.; Berry, R.D.

    1980-04-01

    Solar energy utilization in urban areas requires public guarantees that all property owners have direct access to the sun. The study examines the implications of this premise in relation to the need for cities to also encourage or accommodate rebuilding and future development. The public policy mechanism for guaranteeing solar access is conceptualized as a solar zoning envelope that allows the largest possible building bulk on a land parcel without shadowing neighboring properties during specified times. Step-by-step methods for generating solar envelopes are described with extensive drawings, showing a variety of urban platting and lot configurations. Development and design possibilities are examined on a selected set of Los Angeles sites with typically diverse urban characteristics. Envelope attributes suitable for encouraging moderate-density commercial and residential building are examined in the context of two hypothetical but realistic development programs: one for speculative office buildings and one for condominium housing. Numerous illustrations of envelope forms and prototypical building designs are provided. The results of development simulation studies on all test sites are tabulated to show building bulk, density, land-coverage and open space characteristics obtainable under the hypothesized envelopes.

  12. Policy networking as capacity building : An analysis of regional road development conflict in Indonesia

    NARCIS (Netherlands)

    Hudalah, Delik; Winarso, Haryo; Woltjer, Johan

    2010-01-01

    This article explores the potential of policy networking as an important aspect of capacity building. It deals with a road development project related to the regional planning issue of North Bandung Area (NBA), a water catchment area facing the expansion of Bandung Metropolitan Area, West Java,

  13. Policy networking as capacity building : An analysis of regional road development conflict in Indonesia

    NARCIS (Netherlands)

    Hudalah, Delik; Winarso, Haryo; Woltjer, Johan

    This article explores the potential of policy networking as an important aspect of capacity building. It deals with a road development project related to the regional planning issue of North Bandung Area (NBA), a water catchment area facing the expansion of Bandung Metropolitan Area, West Java,

  14. Measuring Completeness of Building Footprints in OpenStreetMap over Space and Time

    Directory of Open Access Journals (Sweden)

    Carola Kunze

    2013-11-01

    Full Text Available Due to financial or administrative constraints, access to official spatial base data is currently limited to a small subset of all potential users in the field of spatial planning and research. This increases the usefulness of Volunteered Geographic Information (VGI, in particular OpenStreetMap (OSM, as supplementary datasets or, in some cases, alternative sources of primary data. In contrast to the OSM street network, which has already been thoroughly investigated and found to be practically complete in many areas, the degree of completeness of OSM data on buildings is still unclear. In this paper we describe methods to analyze building completeness and apply these to various test areas in Germany. Official data from national mapping and cadastral agencies is used as a basis for comparison. The results show that unit-based completeness measurements (e.g., total number or area of buildings are highly sensitive to disparities in modeling between official data and VGI. Therefore, we recommend object-based methods to study the completeness of OSM building footprint data. An analysis from November 2011 in Germany indicated a completeness of 25% in the federal states of North Rhine-Westphalia and 15% in Saxony. Although further analyses from 2012 confirm that data completeness in Saxony has risen to 23%, the rate of new data input was slowing in the year 2012.

  15. Delivering competence based training and capacity building to support sustainable uranium mining in less prepared areas

    International Nuclear Information System (INIS)

    Miko Dit Angoula, I.; Tulsidas, H.

    2014-01-01

    The IAEA project “Supporting sustainable uranium mining in less prepared areas” consists of a 3-year catalytic training and capacity building of a range of work packages/tasks targeted on technical, operational, regulatory, environmental, stakeholders and governance needs in uranium mining of African francophone uranium producer or potential producer countries. The project is externally funded by a contribution from the USA. The scope is defined by the identification and the delivery of training and further capacity-building measures to enhance national and regional preparedness in these francophone Member States for the conduct of sustainable uranium mining and production, with particular reference to environmental, social, economic issues and good governance within the context of fostering good, safe practices in the comprehensive extraction of all possible economic resources from the mining process.

  16. Building physics from physical principles to international standards

    CERN Document Server

    Pinterić, Marko

    2017-01-01

    This textbook provides thorough coverage of the most important building physics phenomena: heat transfer, moisture, sound/acoustics, and illumination. Since the book is primarily aimed at engineers, it addresses professional issues with due pragmatism, and by including many practical examples and related ISO standards. Nevertheless, in order to guarantee full comprehension, it also explains the underlying physical principles and relates them to practical aspects in a simple and clear way. This is achieved with the aid of more than 100 figures and consistent cross-referencing of formulas and ideas. In addition, interrelationships between the different building physics phenomena are elucidated in a way that will enable readers to develop performance specifications that inform the design process. The book will primarily appeal to students of civil engineering and architecture, as well as to all practitioners in these areas who wish to broaden their fundamental understanding of topics in building physics.

  17. NeOn Methodology for Building Ontology Networks: Specification, Scheduling and Reuse

    OpenAIRE

    Suárez-Figueroa, Mari Carmen

    2010-01-01

    A new ontology development paradigm has started; its emphasis lies on the reuse and possible subsequent reengineering of knowledge resources, on the collaborative and argumentative ontology development, and on the building of ontology networks; this new trend is the opposite of building new ontologies from scratch. To help ontology developers in this new paradigm, it is important to provide strong methodological support. This thesis presents some contributions to the methodological area of...

  18. Creating a three level building classification using topographic and address-based data for Manchester

    Science.gov (United States)

    Hussain, M.; Chen, D.

    2014-11-01

    Buildings, the basic unit of an urban landscape, host most of its socio-economic activities and play an important role in the creation of urban land-use patterns. The spatial arrangement of different building types creates varied urban land-use clusters which can provide an insight to understand the relationships between social, economic, and living spaces. The classification of such urban clusters can help in policy-making and resource management. In many countries including the UK no national-level cadastral database containing information on individual building types exists in public domain. In this paper, we present a framework for inferring functional types of buildings based on the analysis of their form (e.g. geometrical properties, such as area and perimeter, layout) and spatial relationship from large topographic and address-based GIS database. Machine learning algorithms along with exploratory spatial analysis techniques are used to create the classification rules. The classification is extended to two further levels based on the functions (use) of buildings derived from address-based data. The developed methodology was applied to the Manchester metropolitan area using the Ordnance Survey's MasterMap®, a large-scale topographic and address-based data available for the UK.

  19. IEA Solar Heating and Cooling Programme Task 16: PV in Buildings

    International Nuclear Information System (INIS)

    Schoen, A.J.N.; Van der Weiden, T.C.J.

    1993-10-01

    In the title program (SHCP), initiated in 1977, twenty countries, including the European Union, participate in a broad spectrum of subjects in the field of thermal, photovoltaic (PV) and passive solar energy. Nineteen Tasks were started so far, of which eleven Tasks are finished. Task 16 deals with the architectural and electrotechnical integration of PV in buildings, aiming at a maximal contribution of solar energy to the energy supply of a building, knowledge increase and transfer with respect to the relation of PV with other components of the energy system of a building, and economic optimization. Task 16 is planned for the period 1990-1995 and is divided in Sub-Tasks A: System Design and Development; B: Building Integration; C: PV-Demonstration Buildings; and D: Technology Communication. In this report the Dutch activities of Task 16, coordinated by Ecofys, are discussed. Reports of 4 Expert Meetings and 3 Workshops are presented. A description (in English) of the first Dutch IEA Demonstration Building, the energy autonomous house in Woubrugge, is given. Finally attention is paid to the activities regarding the Ideas Competition for the design of buildings or urban areas with integrated PV systems. 6 appendices

  20. High-performance commercial building systems

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, Stephen

    2003-10-01

    building owners and health and performance benefits to occupants. At the same time this program can strengthen the growing energy efficiency industry in California by providing new jobs and growth opportunities for companies providing the technology, systems, software, design, and building services to the commercial sector. The broad objectives across all five program elements were: (1) To develop and deploy an integrated set of tools and techniques to support the design and operation of energy-efficient commercial buildings; (2) To develop open software specifications for a building data model that will support the interoperability of these tools throughout the building life-cycle; (3) To create new technology options (hardware and controls) for substantially reducing controllable lighting, envelope, and cooling loads in buildings; (4) To create and implement a new generation of diagnostic techniques so that commissioning and efficient building operations can be accomplished reliably and cost effectively and provide sustained energy savings; (5) To enhance the health, comfort and performance of building occupants. (6) To provide the information technology infrastructure for owners to minimize their energy costs and manage their energy information in a manner that creates added value for their buildings as the commercial sector transitions to an era of deregulated utility markets, distributed generation, and changing business practices. Our ultimate goal is for our R&D effort to have measurable market impact. This requires that the research tasks be carried out with a variety of connections to key market actors or trends so that they are recognized as relevant and useful and can be adopted by expected users. While some of this activity is directly integrated into our research tasks, the handoff from ''market-connected R&D'' to ''field deployment'' is still an art as well as a science and in many areas requires resources and a