WorldWideScience

Sample records for apical sealing ability

  1. Sealing ability of grar MTA AngelusTM, CPM TM and MBPc used as apical plugs.

    Science.gov (United States)

    Orosco, Fernando Accorsi; Bramante, Clovis Monteiro; Garcia, Roberto Brandão; Bernadineli, Norberti; Moraes, Ivaldo Gomes de

    2008-01-01

    This study evaluated the sealing ability of apical plugs fabricated with gray MTA Angelus sealer, CPM TM sealer and MBPc sealer. The root canals of 98 extracted single-rooted human teeth were instrumented with #5 to #1 Gates Glidden drills according to the crown-down technique until the #1 drill could pass through the apical foramen. The specimens were then prepared with K-files, starting with an ISO 50 until an ISO 90 could be visualized 1 mm beyond the apex. After root canal preparation, the external surface of each root was rendered impermeable and roots were assigned to 3 experimental groups (n = 30), which received a 5-mm thick apical plug of gray MTA Angelus, CPM and MBPc, and two control groups (n=4). The remaining portion of the canal in the experimental groups was filled by the lateral condensation technique. The teeth of each group, properly identified, were fixed on utility wax by their crowns and were placed in plastic flasks, leaving the apex free and facing upward. The flasks were filled with 0.2% Rhodamine B solution, pH 7.0, so as to completely cover the root apex of all teeth. The sealing ability was analyzed by measuring 0.2% Rhodamine B leakage after all groups had been maintained in this solution for 48 hours. Data were analyzed statistically by Kruskal-Wallis test and Dunn test with a=5%. The results showed that, among the tested materials used for fabrication of apical plugs, MBPc sealer had the least amount of leakage with statistically significant difference (p<0.05).

  2. Sealing ability of grar MTA AngelusTM, CPM TM and MBPc used as apical plugs

    Directory of Open Access Journals (Sweden)

    Fernando Accorsi Orosco

    2008-02-01

    Full Text Available This study evaluated the sealing ability of apical plugs fabricated with gray MTA AngelusTM sealer, CPM TM sealer and MBPc sealer. The root canals of 98 extracted single-rooted human teeth were instrumented with #5 to #1 Gates Glidden drills according to the crown-down technique until the #1 drill could pass through the apical foramen. The specimens were then prepared with K-files, starting with an ISO 50 until an ISO 90 could be visualized 1 mm beyond the apex. After root canal preparation, the external surface of each root was rendered impermeable and roots were assigned to 3 experimental groups (n = 30, which received a 5-mm thick apical plug of gray MTA AngelusTM, CPM TM and MBPc, and two control groups (n=4. The remaining portion of the canal in the experimental groups was filled by the lateral condensation technique. The teeth of each group, properly identified, were fixed on utility wax by their crowns and were placed in plastic flasks, leaving the apex free and facing upward. The flasks were filled with 0.2% Rhodamine B solution, pH 7.0, so as to completely cover the root apex of all teeth. The sealing ability was analyzed by measuring 0.2% Rhodamine B leakage after all groups had been maintained in this solution for 48 hours. Data were analyzed statistically by Kruskal-Wallis test and Dunn test with a=5%. The results showed that, among the tested materials used for fabrication of apical plugs, MBPc sealer had the least amount of leakage with statistically significant difference (p<0.05.

  3. Determination of the Apical Sealing Abilities of Mineral Trioxide Aggregate, Portland Cement, and Bioaggregate After Irrigation with Different Solutions.

    Science.gov (United States)

    Bayram, H Melike; Saklar, Feridun; Bayram, Emre; Orucoglu, Hasan; Bozkurt, Alperen

    2015-06-01

    The purpose of this study was to investigate the sealing ability of root-end filling materials such as mineral trioxide aggregate (MTA), Portland cement, and bioaggregate (BA) after irrigation with different solutions. We examined 130 human maxillar central teeth. After cutting the teeth at the cementoenamel junction, the root canals were expanded using nickel-titanium rotary instruments. Root canals were filled with AH-plus and gutta-percha. Then, the roots were cut apically, and 3 mm deep retrograde cavities were prepared. The roots were divided 12 experimental groups, consisting 10 teeth each; the positive and negative control groups contained five teeth each. The retrograde cavities were rinsed using ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX), BioPure(™) mixture of a tetracycline isomer, an acid, and a detergent (MTAD), or distilled water. Next, groups 1, 2, 3, and 4 were sealed with MTA; groups 5, 6, 7, and 8 were sealed with Portland cement; and groups 9, 10, 11, and 12 were sealed with BA. Then, apical microleakage was evaluated by using a computerized fluid filtration method. The results of the leakage test were statistically evaluated by the post-hoc Tukey's test. MTA, Portland cement, and BA root-end filling materials showed the least leakage in the CHX and distilled water groups. The highest leakage was observed in the EDTA and MTAD groups. The sealing ability of BA was as good as that of MTA. EDTA and MTAD increased the apical leakage and CHX and distilled water decreased the leakage of the root-end filling materials examined in this study.

  4. An in vitro evaluation of the apical sealing ability of new polymeric endodontic filling systems.

    Science.gov (United States)

    Onay, Emel Olga; Ungor, Mete; Unver, Saadet; Ari, Hale; Belli, Sema

    2009-08-01

    The objective of this study was to compare the short-term sealing abilities of recently introduced polymeric endodontic filling systems. Root canals of 120 extracted and decoronated human single-rooted teeth were instrumented using crown-down technique with HERO Shaper rotary instruments. The roots were divided randomly into 8 groups (6 experimental and 2 control groups of 15 roots each) and filled with different combinations of core and sealer as follows: group 1, RealSeal/Resilon; group 2, RealSeal/Herofill; group 3, Hybrid Root Seal/Resilon; group 4, Hybrid Root Seal/Herofill; group 5, MM-Seal/Resilon; group 6, MM-Seal/Herofill; group 7, positive controls (Herofill only); group 8, negative controls. Apical leakage quantity was evaluated after 1 week by using a fluid filtration model. For each sample, measurements of fluid movement were recorded at 2-minute intervals for a total of 8 minutes, and then averaged. The data were calculated and analyzed using the Kolmogorov-Smirnov test, 1-way analysis of variance (ANOVA), and the Tukey test. Significance was set at P less than .05. Multiple paired comparisons (Tukey test) showed that, of all the groups, MM-Seal/Herofill combination exhibited the least microleakage, and RealSeal/Herofill combination ranked second in this regard. The mean leakage values for the RealSeal/Resilon and MM-Seal/Resilon combinations were both significantly higher than the means for the other 4 experimental groups (P < .01). Hybrid Root Seal combined with Resilon resulted in significantly less microleakage than Hybrid Root Seal combined with Herofill (P = .001). The results suggest that the sealing properties of epoxy-resin-based sealer (MM-Seal) combined with gutta-percha (Herofill) are superior to those of methacrylate-based sealers (Hybrid Root Seal and Realseal) combined with Resilon.

  5. Relationship between the Apical Preparation Diameter and the Apical Seal: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Kaoutar Laslami

    2018-01-01

    Full Text Available Objectives. The aim of the study is to define the relationship between the apical preparation diameter and the apical sealing ability to highlight the importance of the preservation of the diameter and the original position of the apical foramen. Materials and Methods. 50 extracted maxillary incisors were randomly allocated into three groups of 15 teeth each (n = 15 according to the apical preparation size: Group 1: finishing file F1 corresponding to size 20 reached the working length (ProTaper Universal system Dentsply®; Group 2: prepared up to size 30 corresponding to finishing file F30; Group 3: prepared up to size 50 corresponding to finishing file F5. Five teeth were assigned to positive and negative control groups. After the filling of the root canals, the teeth were isolated and immersed in a dye solution, then cut longitudinally, photographed, and the dye penetration were calculated using a computer software. Results. Comparison of the three different apical preparation sizes showed no statistically significant differences regarding the apical microleakage. Conclusion. The most important value of the dye penetration was observed in the group with the largest apical diameter.

  6. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Full Text Available Introduction: Root canal obturation aims at sealing the root canal system to prevent re-contamination of canal and periapical space. Presence of moisture in canal before obturation may posit a negative effect on the quality of canal sealing. Therefore, this study was conducted to investigate the effect of canal contamination with saliva on apical microleakage. Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  7. Sealing ability of cermet ionomer cement as a retrograde filling material.

    Science.gov (United States)

    Aktener, B O; Pehlivan, Y

    1993-03-01

    An in vitro dye leakage study was performed to compare the sealing ability of high copper amalgam with cavity varnish and cermet ionomer cement with and without varnish when used as retrofilling materials. The root canals of 54 maxillary anterior teeth were instrumented and obturated with gutta-percha and sealer. The apical 3 mm of the roots were resected and apical class I cavity preparations were made. The roots were then randomly divided into three groups and retrofilled with one of the experimental materials. After 72 h of immersion in India ink, the roots were cleared and evaluated for leakage with a stereomicroscope. Statistical analysis indicated that the cermet ionomer cement with varnish group had significantly less leakage than the amalgam group (P cermet ionomer cement without varnish group (P 0.05).

  8. Apical sealing ability of two novel root canal sealers: An ex-vivo study

    Directory of Open Access Journals (Sweden)

    Priyanka Setia

    2013-01-01

    Full Text Available Objective: The objective was to compare the sealing ability of two root canal sealers viz.: Hybrid Root SEAL (Sun Medical, Tokyo, Japan and iRoot SP (Innovative BioCeramix Inc., Vancouver, Canada. Materials and Methods: A sample of 60 permanent single rooted, human maxillary central incisors of similar sizes was selected for the study. The teeth were decoronated and randomly divided into two groups viz.: Group A and Group B, comprising of thirty teeth each. In Group A, Hybrid Root SEAL and Group B, iRoot SP were used as root canal sealers along with Gutta-percha cones using lateral condensation technique to obturate the canals. After obturation roots were covered with nail paint except 2.0 mm of root and stored in 0.5% methylene blue dye for 1 week. The teeth were immersed in 10 ml of 65% nitric acid for complete dissolution and subsequently subjected to UV spectrophotometer to quantify the concentration of the dye in each sample. The data were analyzed using the unpaired t-test. Results: The mean dye leakage value in Group B (0.368 was less as compared to Group A (0.408. However, statistically the difference was nonsignificant (P = 0.053. Conclusion: There was no statistically significant difference among the two groups.

  9. "In vitro" evaluation of the apical sealing of root canals obturated with different techniques Avaliação "in vitro" do selamento apical dos canais radiculares em função de diferentes técnicas de obturação

    Directory of Open Access Journals (Sweden)

    Viviane Haiub Brosco

    2003-09-01

    Full Text Available The purpose of this study was to compare the apical sealing of root canals obturated with different techniques. One hundred-six human mandibular incisors were submitted to instrumentation by means of the step-back technique. After instrumentation, one hundred teeth received an impermeable coating on the external surfaces of the crown and root (except for the area nearby the apical foramen. Afterwards, they were divided in five groups containing twenty elements each, according to the obturation technique employed: 1. lateral condensation with Kerr file; 2. continuous wave of condensation technique with System B; 3. thermoplasticized injectable gutta-percha technique with the Ultrafil system; 4. mechanically thermoplasticized gutta-percha with the JS Quick-Fill system and 5. thermoplasticized gutta-percha associated to a master cone with the Microseal system. The six remaining teeth were employed as negative and positive controls. After obturation, the access cavities were sealed and the teeth were immersed in aqueous 2% methylene blue dye for 72 hours at 37ºC. After that, the teeth were longitudinally sectioned and the apical microleakage was evaluated in a stereomicroscope. The Microseal system presented the best apical sealing ability, followed by System B, JS Quick-Fill, Ultrafil and the lateral condensation technique. The statistical analysis of the results demonstrated that: 1. the Microseal system presented an apical sealing similar to System B and better than the other groups; 2. System B presented better apical sealing than the lateral condensation technique, being similar to the other groups; and 3. the lateral condensation, Ultrafil and JS Quick-Fill groups demonstrated similar sealing ability.Este estudo teve como objetivo avaliar o selamento apical de canais radiculares obturados por diferentes técnicas. Cento e seis incisivos inferiores humanos tiveram seus canais instrumentados através da técnica escalonada regressiva. Após a

  10. An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

    Science.gov (United States)

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  11. An In Vitro Comparative Study of the Adaptation and Sealing Ability of Two Carrier-Based Root Canal Obturators

    Directory of Open Access Journals (Sweden)

    Ahmed Alkahtani

    2013-01-01

    Full Text Available The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  12. Sealing ability of mineral trioxide aggregate (MTA) combined with distilled water, chlorhexidine, and doxycycline.

    Science.gov (United States)

    Arruda, Roberta A A; Cunha, Rodrigo S; Miguita, Kenner B; Silveira, Cláudia F M; De Martin, Alexandre S; Pinheiro, Sérgio L; Rocha, Daniel G P; Bueno, Carlos E S

    2012-09-01

    The aim of this study was to evaluate the sealing ability of mineral trioxide aggregate (MTA Bio) combined with different mixing agents (distilled water, chlorhexidine, doxycycline), used as an apical root-end filling material. Forty-two extracted human teeth were divided into three groups (n = 12); six teeth were used as controls. Root-ends were resected at 90 degrees, 3 mm from the apex. Root-end cavities were prepared using ultrasonic tips and filled with MTA Bio plus distilled water, 2% chlorhexidine solution, or 10% doxycycline solution. Apical sealing was assessed by microleakage of 50% silver nitrate solution. Roots were longitudinally sectioned in a buccolingual plane and analyzed using an operating microscope (20× magnification). Depth of dye leakage into the dentinal walls was measured in millimeters. Results were analyzed using ANOVA and Tukey's test (P = 0.05). MTA Bio plus distilled water showed significantly higher mean leakage results (1.06 mm) when compared with MTA Bio plus doxycycline (0.61 mm), and higher, although not significant, results when compared with MTA Bio plus chlorhexidine (0.79 mm). In conclusion, replacing distilled water with two biologically active mixing agents (doxycycline and chlorhexidine) did not alter the sealing properties of MTABio. The antimicrobial properties of these combinations should be further investigated.

  13. Apical sealing of root canal fillings performed with five different endodontic sealers: analysis by fluid filtration

    Directory of Open Access Journals (Sweden)

    Bruno Carvalho de Vasconcelos

    2011-08-01

    Full Text Available OBJECTIVES: To evaluate the sealing ability of five root canal sealers, including two experimental cements (MBP and MTA-Obtura using the fluid filtration method. MATERIAL AND METHODS: Teeth were divided into 5 study groups: G1-AH Plus; G2-Acroseal; G3Sealapex; G4-MBP; G5-MTA-Obtura; and two controls. Chemical-mechanical preparation was performed with ProFile rotary nickel-titanium instruments 1 mm short of the apical foramen. The sealing ability was evaluated by fluid filtration at 15, 30, and 60 days. RESULTS: The statistical analysis showed significant difference between the materials at different periods (p<0.05. AH Plus and MBP had similar leakage values at 15 and 60 days, alternating with significant reduction at 30 days, while the other materials showed progressive increase in leakage values. Acroseal and Sealapex presented the best results at 15 days and the worst at 60 days. CONCLUSIONS: All sealers evaluated presented fluid leakage, with AH Plus and MBP showing the best results at the end of the experimental period. Acroseal, Sealapex, and MTA-Obtura presented increase in leakage values at longer observation periods.

  14. Comparison of the sealing ability of mineral trioxide aggregate and Portland cement used as root-end filling materials.

    Science.gov (United States)

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Eskandarinezhad, Mahsa; Shakouei, Sahar; Unchi, Mahsa

    2011-12-01

    Inadequate apical seal is the major cause of surgical endodontic failure. The root-end filling material used should prevent egress of potential contaminants into periapical tissue. The purpose of this study was to compare the sealing ability of four root-end filling materials: white mineral trioxide aggregate (MTA), gray MTA, white Portland cement (PC) and gray PC by dye leakage test. Ninety-six human single-rooted teeth were instrumented, and obturated with gutta-percha. After resecting the apex, an apical cavity was prepared. The teeth were randomly divided into four experimental groups (A: white MTA, B: gray MTA, C: white PC and D: gray PC; n = 20) and two control groups (positive and negative control groups; n = 8). Root-end cavities in the experimental groups were filled with the experimental materials. The teeth were exposed to Indian ink for 72 hours. The extent of dye penetration was measured with a stereomicroscope at 16× magnification. The negative controls showed no dye penetration and dye penetration was seen in the entire root-end cavity of positive controls. However, there was no statistically significant difference among the four experimental groups (P > 0.05). All retrograde filling materials tested in this study showed the same microleakage in vitro. Given the low cost and apparently similar sealing ability of PC, PC could be considered as a substitute for MTA as a root-end filling material.

  15. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  16. Evaluation of the endodontic apical seal after post insertion by synchrotron radiation microtomography

    International Nuclear Information System (INIS)

    Contardo, L.; De Luca, M.; Biasotto, M.; Longo, R.; Olivo, A.; Pani, S.; Di Lenarda, R.

    2005-01-01

    The commonly used methods for evaluating the endodontic apical seal, such as longitudinal and transversal section and diaphanization, show some operative difficulties and intrinsic limitation. This study suggests and describes a new method of analysis using a synchrotron radiation microtomography to analyse the root apex after post insertion, creating a three-dimensional image and analysing sections of the specimen every 5μm. The study was performed at SYRMEP beam line at the Electra Synchrotron in Trieste using monochromatic X-rays of 32KeV. Eleven monoradicular teeth were prepared using NiTi GT Rotary files instruments to an apical size 20 with conicity .06 and divided in four groups: in G1 (n=4) and G2 (n=2), the specimens were endodontically filled with guttapercha and a zinc-oxide sealer, in G3 (n=3) and G4 (n=2) guttapercha and a silicon-based sealer were used. An endodontic post was inserted in specimens of groups 1 and 3 following the manufacturer's instructions. Specimens were analysed using monochromatic X-rays of 32KeV. A CCD detector with pixel dimension pf 5x5μm 2 was used for the acquisition process. Seven hundred and twenty projections were performed over 180 o range using a high-resolution rotator. The projections were reconstructed using standard algorithms for tomographic reconstruction. The apical infiltration was evaluated by verifying if black spots were detectable on the images. The specimens of groups 3 and 4 showed a better apical seal than the ones of groups 1 and 2. Post insertion, when a ZOE-based sealer is used, increases the apical gap even if it does not seem to be clinically relevant and sufficient to be a cause of endodontic failure. The new method for analysis appeared to be effective to detect small defects in endodontic obturation, analysing guttapercha-sealer and sealer-dentin interfaces

  17. Evaluation of three instrumentation techniques at the precision of apical stop and apical sealing of obturation

    Directory of Open Access Journals (Sweden)

    Özgür Genç

    2011-08-01

    Full Text Available OBJECTIVE: The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepared teeth. MATERIAL AND METHODS: 85 intact human mandibular permanent incisors with single root canal were accessed and the apical constriction was disrupted using a #25 K-file. The teeth were embedded in alginate and instrumented to #40 using rotary Lightspeed or S-Apex techniques or stainless-steel K-files. Distance between the apical foramen and the created apical stop was measured to an accuracy of 0.01 mm. In another set of instrumented teeth, root canals were obturated using gutta-percha and sealer, and leakage was tested at 1 week and 3 months using a fluid filtration device. RESULTS: All techniques performed slightly short of the predetermined level. Closest preparation to the predetermined level was with the manual technique and the farthest was with S-Apex. A significant difference was found between the performances of these two techniques (p<0.05. Lightspeed ranked in between. Leakage was similar for all techniques at either period. However, all groups leaked significantly more at 3 months compared to 1 week (p<0.05. CONCLUSIONS: Despite statistically significant differences found among the techniques, deviations from the predetermined level were small and clinically acceptable for all techniques. Leakage following obturation was comparable in all groups.

  18. Effect of diode laser irradiation on the apical sealing of MTA retrofillings Efeito da irradiação de laser de diodo no selamento apical em retrobturações com MTA

    Directory of Open Access Journals (Sweden)

    Eliana Barbosa de Souza

    2006-09-01

    Full Text Available Apical sealing is essential for the success of paraendodontic surgery, so any procedure that may favor an adequate sealing of the apical remainder should be performed. The purpose of this study was to evaluate the influence of diode laser irradiation on the apical sealing of root-end cavities with MTA retrofillings. Root canals in twenty extracted human teeth were shaped with K-files and filled with gutta-percha. The apexes were cut off and root-end preparations were performed. The roots were divided randomly in 2 groups. Group 1 (ten specimens was retrofilled with MTA. Group 2 was irradiated with diode laser, with 1 W for 20 seconds, on the apical surface and root end cavity before retrofilling with MTA. The specimens had their external surfaces impermeabilized with cyanoacrylate, except for the apical surface, and were then immersed in 1% rhodamine B dye for 72 h and placed in plaster stone. After that, the specimens were submitted to longitudinal abrasion until half of the root remained. The linear dye leakage was observed in these mid-roots between the root canal wall and retrofilling. The linear dye leakage was measured with Image Lab software, and the results were statistically analyzed with Student's t test. There were no statistically significant differences between the two groups (p > 0.05. The diode laser irradiation did not improve the apical sealing of MTA retrofillings under the conditions of this in vitro study.O selamento apical é fundamental para o sucesso da cirurgia parendodôntica. Assim, procedimentos que melhorem o selamento do remanescente apical devem ser utilizados. O objetivo deste estudo foi verificar se a irradiação de laser de diodo poderia aumentar o selamento apical em cavidades retrógradas obturadas com MTA. Foram utilizadas 20 raízes de dentes humanos extraídos que, após preparo com lima tipo K, tiveram seus canais obturados com guta-percha. Os ápices foram cortados e sofreram preparo de cavidades retr

  19. Effect of four different intracanal medicaments on the apical seal of the root canal system: A dye extraction study

    Directory of Open Access Journals (Sweden)

    Monika Tandan

    2014-01-01

    Conclusion: It can be concluded from this study that the control group showed least amount of leakage, whereas the 1% chlorhexidine gel group showed maximum amount of leakage. Apical leakage was observed with all the experimental groups with little variations in between them. Under the parameters of this study, it can be concluded that use of intracanal medicaments during endodontic treatment has a definite impact on the apical seal of the root canal system.

  20. Effect of four different intracanal medicaments on the apical seal of the root canal system: a dye extraction study.

    Science.gov (United States)

    Tandan, Monika; Hegde, Mithra N; Hegde, Priyadarshini

    2014-01-01

    The aim was to determine the effect of four different intracanal medicaments on the apical seal of the root canal system in vitro. Fifty freshly extracted intact human permanent maxillary central incisors were collected, stored and disinfected. The root canals were prepared to a master apical size of number 50 using step back technique. Depending upon the intracanal medicament used, the teeth were divided randomly into five groups of 10 teeth each including one control group and four experimental groups. Group A: No intracanal medicament. Group B: Calcium hydroxide powder mixed with distilled water. Group C: Calcium hydroxide gutta percha points (calcium hydroxide points). Group D: 1% chlorhexidine gel (hexigel). Group E: Chlorhexidine gutta percha points (Roeko Activ Points). The medication was left in canals for 14 days. Following removal of the intracanal medicament, all the groups were obturated with lateral compaction technique. The apical leakage was then evaluated using dye extraction method with the help of a spectrophotometer. RESULTS were statistically analyzed using Kruskal-Wallis and Mann-Whitney U-test, which showed statistically significant difference among the five groups tested. It can be concluded from this study that the control group showed least amount of leakage, whereas the 1% chlorhexidine gel group showed maximum amount of leakage. Apical leakage was observed with all the experimental groups with little variations in between them. Under the parameters of this study, it can be concluded that use of intracanal medicaments during endodontic treatment has a definite impact on the apical seal of the root canal system.

  1. Sealing ability of a new polydimethylsiloxane-based root canal filling material

    NARCIS (Netherlands)

    Özok, A.R.; van der Sluis, L.W.M.; Wu, M.K.; Wesselink, P.R.

    2008-01-01

    We tested the null hypothesis that there is no difference in the sealing ability of GuttaFlow, RoekoSeal, and AH26 in root canals. Sixty extracted mandibular premolars were filled with AH26 (lateral compaction), RoekoSeal, or GuttaFlow (modified single-cone). The sealing ability of the root canal

  2. Sealing ability of a new polydimethylsiloxane-based root canal filling material

    NARCIS (Netherlands)

    Ozok, Ahmet R.; van der Sluis, Lucas W. M.; Wu, Min-Kai; Wesselink, Paul R.

    We tested the null hypothesis that there is no difference in the sealing ability of GuttaFlow, RoekoSeal, and AH26 in root canals. Sixty extracted mandibular premolars were filled with AH26 (lateral compaction), RoekoSeal, or GuttaFlow (modified single-cone). The sealing ability of the root canal

  3. Assessment of Marginal Adaptation and Sealing Ability of Root Canal Sealers: An in vitro Study.

    Science.gov (United States)

    Remy, Vimal; Krishnan, Vineesh; Job, Tisson V; Ravisankar, Madhavankutty S; Raj, C V Renjith; John, Seena

    2017-12-01

    This study aims to compare the marginal adaptation and sealing ability [mineral trioxide aggregate (MTA)-Fillapex, AH Plus, Endofill sealers] of root canal sealers. In the present study, the inclusion criteria include 45 single-rooted extracted mandibular premolar teeth, with single canal and complete root formation. The sectioning of the samples was done at the cementoenamel junction using a low-speed diamond disc. Step-back technique was used to prepare root canals manually. The MTA-Fillapex, AH Plus, and Endofill sealers were the three experimental sealer groups to which 45 teeth were distributed. Under scanning electron microscope (SEM), marginal gap at sealer and root dentin interface were examined at coronal and apical halves of root canal. Among the three maximum marginal adaptations were seen with AH Plus sealer (4.10 ± 0.10) which is followed by Endofill sealer (1.44 ± 0.18) and MTA-Fillapex sealer (0.80 ± 0.22). Between the coronal and apical marginal adaptation, significant statistical difference (p = 0.001) was seen in AH Plus sealer. When a Mann-Whitney U-test was done on MTA-Fillapex sealer vs AH Plus sealer and AH Plus sealer vs Endofill sealer, there was a statistically significant difference (p marginal adaptation when compared with other sealers used. For sealing space of crown wall and main cone in root canal treatment, sealers play an important role. The other advantages of sealers are that they are used to fill voids and irregularities in root channel, secondary, lateral channels, and space between applied gutta-percha cones and also act as tripper during filling.

  4. 5-year results comparing mineral trioxide aggregate and adhesive resin composite for root-end sealing in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Hänni, Stefan; Jensen, Simon Storgård

    2014-01-01

    was designed to re-examine a large sample of teeth treated with apical surgery after 5 years. METHODS: Patients were recalled 5 years after apical surgery, and treated teeth were classified as healed or not healed based on clinical and radiographic examination. (The latter was performed independently by 3......, age, type of tooth treated, post/screw, type of surgery). CONCLUSIONS: The results from this prospective nonrandomized clinical study with a 5-year follow-up of 271 teeth indicate that MTA exhibited a higher healing rate than COMP in the longitudinal prognosis of root-end sealing.......INTRODUCTION: Recent meta-analyses of the outcome of apical surgery using modern techniques including microsurgical principles and high-power magnification have yielded higher rates of healing. However, the information is mainly based on 1- to 2-year follow-up data. The present prospective study...

  5. Sealing ability of MTA, CPM, and MBPc as root-end filling materials: a bacterial leakage study.

    Science.gov (United States)

    Medeiros, Paulo Leal; Bernardineli, Norberti; Cavenago, Bruno Cavalini; Torres, Sérgio Aparecido; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Marciano, Marina Angélica

    2016-04-01

    Objectives To evaluate the sealing ability of three root-end filling materials (white MTA, CPM, and MBPc) using an Enterococcus faecalis leakage model. Material and Methods Seventy single-root extracted human teeth were instrumented and root-ends were resected to prepare 3 mm depth cavities. Root-end preparations were filled with white MTA, CPM, and MBPc cements. Enterococcus faecalis was coronally introduced and the apical portion was immersed in BHI culture medium with phenol red indicator. The bacterial leakage was monitored every 24 h for 4 weeks. The statistical analysis was performed using the Wilcoxon-Gehan test (pCPM and the other groups. Conclusions The epoxy resin-based cement MBPc had lower bacterial leakage compared with the calcium silicate-based cements MTA and CPM.

  6. Zinc oxide nano-particles as sealer in endodontics and its sealing ability

    Directory of Open Access Journals (Sweden)

    Maryam Javidi

    2014-01-01

    Full Text Available Aims: The aim of this study was to evaluate the sealing ability of new experimental nano-ZOE-based sealer. Settings and Design: Three types of nano-ZOE-based sealer (calcined at different temperatures of 500, 600 and 700°C with two other commercially available sealers (AH26 and micro-sized zinc oxide eugenol sealer were used. Materials and Methods: Zinc oxide nano-particles were synthesized by a modified sol-gel method. The structure and morphology of the prepared powders were characterized using x-ray diffraction (XRD and transmission electron microscopy (TEM techniques. The instrumented canals of 60 single-rooted teeth were divided into five groups (n = 10, with the remaining ten used as controls. The canals were filled with gutta-percha using one of the materials mentioned above as sealer. After 3, 45 and 90 days, the samples were connected to a fluid filtration system. Statistical Analysis Used: The data were analyzed using Student′s t-test. Results: The XRD patterns and TEM images revealed that all the synthesized powders had hexagonal wurtzite structures with an average particle size of about 30-60 nm at different calcination temperatures. Microleakage in AH26 groups was significantly more than that in three groups of ZnO nano-particles at all the three evaluation intervals. Apical microleakage of ZnO micro-powders was significantly more than that of all the materials, but the sealing ability of ZnO nano-powder sealers did not differ significantly. Conclusion: The results of this study showed that the synthesized ZnO nano-powder sealers are suitable for use as a nano-sealer in root canal therapy to prevent leakage; however, further studies should be carried out to verify their safety.

  7. Healing of apical rarefaction of three nonvital open apex anterior teeth using a white portland cement apical plug

    Directory of Open Access Journals (Sweden)

    Amitabha Chakraborty

    2012-01-01

    Full Text Available The major challenge of performing root canal treatment in an open apex pulp-less tooth is to obtain a good apical seal. MTA has been successfully used to achieve a good apical seal, wherein the root canal obturation can be done immediately. MTA and White Portland Cement has been shown similarity in their physical, chemical and biological properties and has also shown similar outcome when used in animal studies and human trials. In our study, open apex of three non vital upper central incisors has been plugged using modified white Portland cement. 3 to 6 months follow up revealed absence of clinical symptoms and disappearance of peri-apical rarefactions. The positive clinical outcome may encourage the future use of white Portland cement as an apical plug material in case of non vital open apex tooth as much cheaper substitute of MTA.

  8. Comparison of apical centring ability between incisal-shifted access and traditional lingual access for maxillary anterior teeth.

    Science.gov (United States)

    Yahata, Yoshio; Masuda, Yoshiko; Komabayashi, Takashi

    2017-12-01

    The aim of this study was to compare the apical centring ability of incisal-shifted access (ISA) with that of traditional lingual access (TLA). Fifteen three-dimensional printed resin models were prepared from the computed tomography data for a human maxillary central incisor and divided into ISA (n = 7), TLA (n = 7) and control (n = 1) groups. After access preparation, these models were shaped to the working length using K-files up to #40, followed by step-back procedures. An apical portion of the model was removed at 0.5 mm coronal to the working length. Microscopic images of each cutting surface were taken to measure the preparation area and the distance of transportation. TLA created a larger preparation area than ISA (P < 0.05). The distance of transportation (mean ± standard deviation) was 0.4 ± 0.1 mm for ISA and 0.7 ± 0.1 mm for TLA (P < 0.05). Access cavity preparation has a significant effect on apical centring ability. ISA is beneficial to maintaining apical configuration. © 2017 Australian Society of Endodontology Inc.

  9. Evaluation of apical microleakage of teeth sealed with four different root canal sealers Avaliação da microinfiltração apical em dentes obturados com quatro diferentes cimentos endodônticos

    Directory of Open Access Journals (Sweden)

    Fábio Dultra

    2006-10-01

    Full Text Available OBJECTIVES: to compare the apical sealing ability of four root canal sealers. MATERIAL AND METHODS: forty extracted human maxillary canines were instrumented 1 mm short of the anatomical apex and randomly assigned to four groups (n=10, according to the root canal sealer used for obturation: Endofill, AH Plus, EndoREZ and Epiphany. Root canals were obturated with gutta-percha points, except for the Epiphany group, in which resin points (Resilon were used. The teeth were immersed in India ink for seven days and clarified using methyl salicylate. The extent of apical dye penetration was measured with a measuroscope in all aspects of the canal. RESULTS: AH Plus (0.02 mm ± 0.07, Epiphany (0.00 mm ± 0.00 and EndoREZ (0.32 mm ± 0.62 did not differ statistically to each other (p>0.01. EndoFill presented the highest dye penetration mean (0.83 mm ± 0.73 and was statistically different from the other sealers (pOBJETIVOS: comparar a capacidade de selamento apical de quatro cimentos endodônticos. MÉTODOS: quarenta caninos superiores humanos extraídos foram instrumentados 1 mm aquém do ápice anatômico e distribuídos aleatoriamente em quatro grupos (n=10, de acordo com o cimento endodôntico utilizado para a obturação: Endofill, AH Plus, EndoREZ e Epiphany. Os canais radiculares foram obturados pela técnica da condensação lateral com os cimentos e com cones de guta-percha, exceto o grupo do Epiphany, no qual os cones de resina (Resilon foram utilizados. Os dentes foram imersos em nanquim por sete dias e submetidos ao processo de diafanização e, então, clarificados empregando-se o salicilato de metila. A extensão de penetração via apical do corante foi medida por meio de um microscópio de mensuração em todas as faces do terço apical. RESULTADOS: AH Plus (0,02 mm ± 0,07, Epiphany (0,00 mm ± 0,00 e EndoREZ (0,32 mm ± 0,62 não diferiram estatisticamente entre si (p>0,01. EndoFill apresentou a maior média de penetração do corante (0

  10. Non-surgical retreatment of a failed apicoectomy without retrofilling using white mineral trioxide aggregate as an apical barrier.

    Science.gov (United States)

    Stefopoulos, Spyridon; Tzanetakis, Giorgos N; Kontakiotis, Evangelos G

    2012-01-01

    Root-end resected teeth with persistent apical periodontitis are usually retreated surgically or a combination of non-surgical and surgical retreatment is employed. However, patients are sometimes unwilling to be subjected to a second surgical procedure. The apical barrier technique that is used for apical closure of immature teeth with necrotic pulps may be an alternative to non-surgically retreat a failed apicoectomy. Mineral trioxide aggregate (MTA) has become the material of choice in such cases because of its excellent biocompatibility, sealing ability and osseoinductive properties. This case report describes the non-surgical retreatment of a failed apicoectomy with no attempt at retrofilling of a maxillary central incisor. White MTA was used to induce apical closure of the wide resected apical area. Four-year follow-up examination revealed an asymptomatic, fully functional tooth with a satisfactory healing of the apical lesion. White MTA apical barrier may constitute a reliable and efficient technique to non-surgically retreat teeth with failed root-end resection. The predictability of such a treatment is of great benefit for the patient who is unwilling to be submitted to a second surgical procedure.

  11. A Comparative Study of Apical Healing of Open Apices Using MTA and Ca(OH2 Apical Plugs in Cats

    Directory of Open Access Journals (Sweden)

    M. H. Zarrabi

    2005-06-01

    Full Text Available Statement of problem: Endodontic treatment of necrotic teeth with open apices is a challenge. After ruling out surgery as a treatment scheme and introduction of the multivisit apexification which in turn had its disadvantages, apical plug seems to be a suitable substitute treatment plan for such cases. Apical plug makes the treatment through formation of a barrier against the obturating material in a single visit.Purpose: The purpose of this study was to compare histologically the periapical healing using MTA and calcium hydroxide apical plugs after intervals of 4 and 12 weeks in cats.Materials and Methods: In this clinical trial study 64 canines of 16 healthy and mature cats were divided into 3 groups after a periapical lesion formation by over instrumentation in the apical area with files up to no.120. The first group included 24 teeth on which MTA apical plug was applied. The second group included 24 teeth on which Ca (OH 2 apical plug was applied. In both groups the canals were filled with gutta percha and sealer. The third group included 16 control teeth whose canals were left empty after instrumentation and debridement. The access cavities of all teeth were sealed with varnish and amalgam and the vital perfusion of cats was performed in 4 and 12 week intervals. Statistical analysis was established by χ2 and independence test.Results: After 4 weeks, periapical healing in the first group was 90%, in the second group 80% and in the third group, it was only 12.5 %. After 12 weeks, periapical healing occurred in 100% of the MTA group, while it was 57.1% in the second and 40%in the third group .Generally, in the study of histological parameters of healing, no statistical significant difference was observed between the 2 experimental groups,although the MTA group results were much better than the Ca (OH 2 group especially at 12 weeks.Conclusion: The use of MTA apical plug is more effective than Ca (OH 2 in treatment of necrotic teeth with open

  12. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate as a root end filling material: An ex vivo evaluation

    Directory of Open Access Journals (Sweden)

    Sreegowri

    2013-01-01

    Full Text Available Aim: The aim of this study was to evaluate the sealing ability of white and gray mineral trioxide aggregate (MTA mixed with distilled water and 0.12% chlorhexidine (CHX gluconate when used as a root-end filling material using the dye-penetration technique. Materials and Methods: A total of 48 single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH Plus sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 8 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After application of nail polish, the teeth were exposed to India ink for 72 h and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. Results : No statistically significant differences were observed in the sealing ability of gray and white MTA mixed with distilled water and 0.12% CHX. Conclusion : CHX appears to be a good alternative to replace distilled water, as a solution to be mixed with MTA.

  13. Dental Pulp Revascularization of Necrotic Permanent Teeth with Immature Apices.

    Science.gov (United States)

    El Ashiry, Eman A; Farsi, Najat M; Abuzeid, Sawsan T; El Ashiry, Mohamed M; Bahammam, Hammam A

    The treatment of immature necrotic teeth with apical periodontitis presents challenges in endodontic and pediatric dentistry. Revascularization is a recent treatment for such cases as an alternative to conventional apexification. The purpose is to examine the effect of a pulpal revascularization procedure on immature necrotic teeth with apical periodontitis. Twenty patients were enrolled for pulp revascularization procedure by root canal disinfection using a triple antibiotic mixture for 1-2 weeks, followed by creating a blood clot, sealing the root canal orifice using white mineral trioxide aggregate and a coronal seal of composite resin. Patients were recalled periodically for up to 24 months. During follow-up, all patients were asymptomatic. Three cases of chronic apical periodontitis showed clinical disappearance of the sinus tract 2 weeks after treatment. Radiography revealed progressive periapical radiolucency resolution within the first 12 months. Within 12-24 months, the treated teeth showed progressive increases in dentinal wall thickness, root length and continued root development. Clinical and radiographic evidence showed successful revascularization treatments of immature necrotic permanent teeth with apical periodontitis. More studies are necessary to understand the underlying mechanisms and to perform histopathology of the pulp space contents after revascularization procedures.

  14. Cimentos endodônticos - selamento marginal apical imediato e após armazenamento de seis meses Endodontic cements - immediate apical sealing and after a six-month storage

    Directory of Open Access Journals (Sweden)

    Marcia Carneiro VALERA

    1998-10-01

    Full Text Available Este trabalho avaliou o selamento marginal apical de canais radiculares obturados com os cimentos endodônticos Sealapex, Apexit, Sealer 26 e Ketac Endo. Utilizaram-se 136 raízes, cujos canais radiculares, após o preparo biomecânico, foram obturados pela técnica da condensação lateral ativa com os cimentos em estudo. Metade das amostras, imediatamente após as obturações, foram imersas na solução de azul de metileno a 2% e a outra metade após 6 meses de armazenamento em plasma sangüíneo humano. Observou-se que os cimentos Sealapex e Sealer 26 apresentaram infiltrações médias estatisticamente iguais entre si e menores que as observadas para os demais cimentos (p The aim of this study was to verify the apical sealing of root canals obturated with Sealapex, Apexit, Sealer 26, and Ketac Endo cements. A hundred and thirty six dental roots were used for the experiment. After biomechanical preparation and lateral condensation filling, half of the roots were placed in human blood plasma storage medium for 6 months. The remaining samples were immediately placed in methylene blue, under a temporary vacuum, and after one week the amount of dye penetration measured. The stored samples were similarly treated after the 6-month storage period. Statistical analysis of the results revealed that the groups obturated with Sealapex and Sealer 26 showed the smallest amount of apical leakage (p < 0.05. There were significant differences in the amount of dye penetration after 6 months of storage (1.275 mm, when compared to the results found without storage (0.829 mm (p < 0.05.

  15. Apical Transportation, Centering Ability, and Cleaning Effectiveness of Reciprocating Single-file System Associated with Different Glide Path Techniques.

    Science.gov (United States)

    de Carvalho, Guilherme Moreira; Sponchiado Junior, Emílio Carlos; Garrido, Angela Delfina Bittencourt; Lia, Raphael Carlos Comelli; Garcia, Lucas da Fonseca Roberti; Marques, André Augusto Franco

    2015-12-01

    The aim of this study was to evaluate the apical transportation, the centering ability, and the cleaning effectiveness of a reciprocating single-file system associated to different glide path techniques. The mesial root canals of 52 mandibular molars were randomly distributed into 4 groups (n = 13) according to the different glide path techniques used before biomechanical preparation with Reciproc System (RS): KF/RS (sizes 10 and 15 K-files), NGP/RS (no glide path, only reciprocating system), PF/RS (sizes 13, 16, and 19 PathFile instruments), and NP (no preparation). Cone-beam computed tomography analysis was performed before and after instrumentation for apical third images acquisition. Apical transportation and its direction were evaluated by using the formula D = (X1 - X2) - (Y1 - Y2), and the centering ability was analyzed by the formula CC = (X1 - X2/Y1 - Y2 or Y1 - Y2/X1 - X2). The samples were submitted to histologic processing and analyzed under a digital microscope for debris quantification. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test, P .05). Groups had a tendency toward transportation in the mesial direction. No technique had perfect centering ability (=1.0), with no significant difference among them. KF/RS had larger amount of debris, with statistically significant difference in comparison with NGP/RS (P > .05). The different glide path techniques promoted minimal apical transportation, and the reciprocating single-file system tested remained relatively centralized within the root canal. Also, the different techniques interfered in the cleaning effectiveness of the reciprocating system. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. An investigation on the effects of resection angle on apical sea!

    Directory of Open Access Journals (Sweden)

    Razmi H

    2003-08-01

    Full Text Available Statement of Problem: The goal of a successful endodontic surgery is to establish an adequate seal in apical region. Therefore during surgery, root-end resection is essential for an appropriate situation and proper access."nPurpose: The aim of this study was to determine the most appropriate root-end resection angle to establish adequate apical seal in periapical surgery,"nMaterials and Methods: Forty-five intact extracted human maxillary central incisors were randomly divided into three 15-tooth groups. The root canals were instrumented and then obturated using lateral condensation technique. AM roots were resected at 3mm from apical portion. Angles of root resection for each group were 0, 30 and 45 degrees. Then all teeth surfaces, except the cut ones, were covered with nail polish and immersed in methylen blue for 7 days. After 7 days, nail polish was removed from the surfaces and samples were split in buccolingual direction. Then, dye penetration (mm was measured using a stereozoom microscope (Loupe [X4 magnification] and eye lens. In order to analyze the data, unilateral variance analysis was used."nResults: The values of dye penetration were: 7.23±3.34 (0°, 8.46±3.01(30° and 9.74±4.11 (45°. There"nwas no significant difference between three groups (P>0.05. Conclusion: It is suggested that the angle of root-end resection put a limited effect on apical seal if retrograde cavity depth is increased.

  17. Effect of Nd:YAG and Diode Lasers on Apical Seal of Root Canals Filled with AH Plus and Mineral Trioxide Aggregate-Based Sealers

    Directory of Open Access Journals (Sweden)

    Elham Khoshbin

    2018-01-01

    Full Text Available Objectives: Laser irradiation, as an adjunct to root canal preparation, may increase the success rate of endodontic treatments. This study aimed to assess the effect of neodymium-doped yttrium aluminum garnet (Nd:YAG and diode lasers on the apical seal of the root canals filled with AH Plus® and mineral trioxide aggregate (MTA-based sealers.Materials and Methods: This in-vitro experimental study was conducted on 96 single-rooted, single-canal extracted human teeth with closed apices. The root canals were prepared by using ProTaper® rotary instruments and were randomly divided into six groups (n=16: 940-nm diode laser and AH Plus® sealer (group 1, Nd:YAG laser and AH Plus® sealer (group 2, AH Plus® sealer (group 3, 940-nm diode laser and MTA-based sealer (group 4, Nd:YAG laser and MTA-based sealer (group 5, MTA-based sealer (group 6, as well as positive and negative control groups. A bacterial leakage model was used for microleakage assessment. Qualitative assessment was done by using a scanning electron microscope (SEM. Data were analyzed by two-way analysis of variance (ANOVA at the significance level of 0.05.Results: There were statistically significant differences between the experimental and control groups (P=0.002. The laser-treated groups showed a lower apical microleakage compared to the non-laser-treated groups, although the difference was not statistically significant (P>0.05. No significant differences were noted between the two lasers in terms of the apical microleakage, irrespective of the type of sealer (P>0.05.Conclusions: Laser irradiation, as an adjunct to root canal preparation, has no significant effect on the level of apical microleakage.

  18. Effect of immediate and delayed post space preparation on the apical seal of root canals obturated with different sealers and techniques

    Directory of Open Access Journals (Sweden)

    Hikmet Aydemir

    2009-12-01

    Full Text Available During mechanical preparation of the post space, the root canal filling may be twisted or vibrated, depending on several factors associated with the preparation technique and quality of filling. OBJECTIVE: The purpose of this study was to investigate the effect of immediate and delayed post space preparation on the integrity of the apical seal. MATERIAL AND METHODS: Sixty-four extracted human incisors were biomechanically prepared using the step-back technique. Sixty roots were randomly assigned to 6 experimental groups of 10 teeth each and the remaining 4 roots served as positive and negative controls (n=2. The root canals in the different groups were obturated with cold lateral and warm vertical condensation of gutta-percha and one of two sealers (Sealapex and Diaket. Post space was prepared either individually or simultaneously. An insulated copper wire was cut into 10-cm-long pieces. In each canal, one piece was inserted to maintain contact with gutta-percha and extended to the outside as one of two working electrodes. A stainless steel wire with the same dimensions of those of the copper wire, used as the other working electrode, was immersed into the background electrolyte from the center of the bottle. The electrical current between standard and experimental electrodes in canals was measured over a period of 10 days applying a conductivity meter. The Kruskal-Wallis test (p=0.05 determined whether there was a significant difference in microleakage among the groups and the Mann-Whitney U test (p=0.01 was used for multiple comparison grouping variables. RESULTS: The results suggest that only the differences between the root canal filling techniques were statistically significant (p0.01. CONCLUSION: The quality of the root canal filling is important for the integrity of the apical seal.

  19. Analysis of marginal seal of ProRoot MTA, MTA Angelus biodentine, and glass ionomer cement as root-end filling materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Sakshi Malhotra

    2015-01-01

    Conclusion: Microleakage was present in all the samples. Least amount of apical dye microleakage was seen in biodentine with mean value of 0.16 mm followed by ProRoot MTA 0.68 mm, MTA Angelus 0.74 mm, and GIC 1.53 mm. The best sealing ability was seen in biodentine, and this difference was statistically significant.

  20. Sealing ability of hydroxyapatite as a root canal sealer: in vitro study

    Directory of Open Access Journals (Sweden)

    Widowati Witjaksono

    2007-09-01

    Full Text Available Hydroxyapatite (HA is the most thermodynamically synthetic calcium phosphate cement, and has indicated useful as a sealer because can seal a furcation perforation, is shown to be biocompatible and also has potential to promote the healing of bone in endodontic therapy. The objective of this study is to determine the sealing ability of HA produced by School of Engineering, Universiti Sains Malaysia (USM when used as a sealer in root canal obturation, compare with Tubli-seal (Zinc-Oxide base and Sealapax (Calcium Hydroxyde base sealers. Forty five single rooted human anterior teeth were instrumented and randomly divided into three experimental groups of 15 teeth each. All teeth in the experimental groups were obturated with laterally condensed gutta percha technique. Teeth in the first group were sealed using Zinc-Oxide (ZnO based sealer and those of second group using Calcium Hydroxide (CaOH based root canal sealer. Third experimental group was sealed using HA from School of Engineering USM. Teeth were then suspended in 2% methylene blue. After this, teeth were demineralized dehydrated and cleared. Linear dye penetration was determined under magnifying lense with calibrated eye piece. Statistical analyses of the linear dye penetration were performed with Kruskal Wallis test. The intergroup comparison between HA and ZnO groups and CaOH groups were analyzed by Mann-Whitney test. The dye penetration for group which were sealed with HA exhibited the lowest penetration and it showed that there was a statistically significant difference both between HA and ZnO groups and also between HA and CaOH groups (p < 0.001.In conclusion, it was found that value added HA based endodontic material which were produced by USM can be used as a root canal sealing materials when it used in combination with epoxy resin since it leaked comparatively less as compared to ZnO and CaOH sealers. Before reaching a definitive conclusion, this material requires further extensive

  1. Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials

    Directory of Open Access Journals (Sweden)

    Pablo Andrés AMOROSO-SILVA

    2014-08-01

    Full Text Available This study compared the fluid filtration, adaptation to the root canal walls, and the push-out bond strength of two resin-based sealers and three calcium silicate-based retrograde filling materials. Fifty maxillary canines were shaped using manual instruments and the apical portion was sectioned. Retrograde cavities of 3-mm depth were prepared. The specimens were divided into five groups (n = 10: Sealer 26 (S26; MBPc (experimental; MTA; Portland cement with 20% zirconium oxide (PC/ZO, and Portland cement with 20% calcium tungstate (PC/CT. The fluid filtration was measured at 7 and 15 days. To evaluate the interfacial adaptation, sections of the teeth, 1 and 2 mm from the apex, were prepared and the percentage of gaps was calculated. The push-out bond strength at 2 mm from the apex was evaluated. Statistical analysis was performed using the ANOVA/Tukey’s test (p < 0.05. At 7 and 15 days (p = 0.0048, p = 0.006, the PC/CT group showed higher fluid filtration values when compared to other groups. At 1 mm from the apex, no statistical differences in the adaptation were found among the cements (p = 0.44. At 2 mm from the apex, the PC/ZO group presented statistically lower percentage of gaps than S26, MBPc, and MTA (p = 0.0007. The MBPc group showed higher push-out bond strength than other cements evaluated (p = 0.0008. The fluid filtration and interfacial adaptation of the calcium silicate-based cements were similar to those of the resin-based cements. The resinous cement MBPc showed superior push-out bond strength.

  2. Setting time and sealing ability of alpha-tricalcium phosphate cement containing titanic oxide.

    Science.gov (United States)

    Yoshikawa, M; Terada, Y; Toda, T

    1998-10-01

    We developed a new type of calcium phosphate cement for clinical use in endodontics as a root canal sealer or pulp cupping agent. The solid phase of the sealer is composed of 70% of alpha-tricalcium phosphate (alpha-TCP) and 30% of titanic oxide (TiO2), and the liquid phase is 37% citric acid, 5% tannic acid and 58% distilled water. TiO2 was added to control setting time and handling of the cement. We used commercially available calcium phosphate root canal sealer as a control. ISO standards specify that new endodontic products should be examined thoroughly before clinical use. It is important to carry out in vitro cytotoxicity and in vivo histocompatibility tests. We first did in vitro test of setting time and root canal sealing ability of the cement. We found that this developed calcium phosphate cement had an appropriate setting time and excellent sealing ability as a root canal sealer, and concluded that it was suitable for clinical use as a root canal sealer.

  3. Single-visit endodontic treatment of mature teeth with chronic apical abscesses using mineral trioxide aggregate cement: a randomized clinical trial.

    Science.gov (United States)

    Alsulaimani, Reem Siraj

    2016-08-23

    Mature teeth with chronic apical abscesses characterized by intermittent discharge of pus through an associated sinus tract. This communication between oral mucosa and periapical inflammation is challenging for the sealing ability of root canal obturation material. Therefore, the study aim was to compare the outcomes of endodontic treatment using mineral trioxide aggregate (MTA) cement to the conventional gutta-percha cone and root canal sealer as an obturation material in mature teeth with chronic apical abscesses. Mature teeth with chronic apical abscesses referred to our clinic for root canal treatment between 2010 and 2012 were treated in a single visit and distributed among treatment (T) and control (C) groups using a predetermined randomization block (TCTC). After chemo-mechanical preparation, teeth in group T received MTA cement mixed in a 0.26 water to powder ratio, and teeth group C received gutta-percha and root canal sealer using the warm vertical technique. The treatment outcomes were defined as obturation length, periapical healing, resorption of extruded material, and survival rate at least 2.5 years after treatment. Three endodontists blinded to the type of obturation material documented treatment outcomes. Statistical analysis at P chronic apical abscesses using MTA cement were better, but not statistically significant, compared to conventional treatment. ISRCTN15285974 . Registered retrospectively 23 June 2015.

  4. Semiconductor laser irradiation improves root canal sealing during routine root canal therapy

    Science.gov (United States)

    Hu, Xingxue; Wang, Dashan; Cui, Ting; Yao, Ruyong

    2017-01-01

    Objective To evaluate the effect of semiconductor laser irradiation on root canal sealing after routine root canal therapy (RCT). Methods Sixty freshly extracted single-rooted human teeth were randomly divided into six groups (n = 10). The anatomic crowns were sectioned at the cementoenamel junction and the remaining roots were prepared endodontically with conventional RCT methods. Groups A and B were irradiated with semiconductor laser at 1W for 20 seconds; Groups C and D were ultrasonically rinsed for 60 seconds as positive control groups; Groups E and F without treatment of root canal prior to RCT as negative control groups. Root canal sealing of Groups A, C and E were evaluated by measurements of apical microleakage. The teeth from Groups B, D and F were sectioned, and the micro-structures were examined with scanning electron microscopy (SEM). One way ANOVA and LSD-t test were used for statistical analysis (α = .05). Results The apical sealing of both the laser irradiated group and the ultrasonic irrigated group were significantly different from the control group (pirrigated group (p>0.5). SEM observation showed that most of the dentinal tubules in the laser irradiation group melted, narrowed or closed, while most of the dentinal tubules in the ultrasonic irrigation group were filled with tooth paste. Conclusion The application of semiconductor laser prior to root canal obturation increases the apical sealing of the roots treated. PMID:28957407

  5. Similar expression of through-and-through fluid movement along orthograde apical plugs of MTA Bio and white Portland cement.

    Science.gov (United States)

    De-Deus, G; Audi, C; Murad, C; Fidel, S; Fidel, R

    2008-12-01

    To compare the sealing ability of four hydraulic cements when used as an apical plug in teeth with wide-open apices. A sample of 70 maxillary central incisors were divided into four groups (n = 15) and a further 10 teeth served as controls. An artificial open apex was created in the teeth using Gates Glidden drills numbers 6-1 in a crown-down manner until the size 1 bur passed through the foramen. A divergent open apex was prepared to a size of 1.24 mm at the foramen by retrograde apical transportation using a number 8 (0.60) Profile Series 29 0.4 taper instrument inserted to the length of the cutting blade. In G1, the open apices were repaired with WMTA Angelus whilst in G2, G3 and G4 MTA Bio, Pro-Root MTA and Portland cement was employed respectively. Each root was assembled in a hermetic cell to allow the evaluation of fluid filtration. Leakage was measured by the movement of an air bubble travelling within a pipette connected to the teeth. Measurements of the air bubble movement were made after 10 min at a constant pressure of 50 cm H(2)O. The Kruskal-Wallis H-test was applied to the fluid flow data to detect differences between the experimental groups (P 0.05). Fluid movement through teeth with open apices and filled with four hydraulic cements was similar. All cements allowed fluid movement.

  6. One-dimensional self-sealing ability of bentonites in artificial seawater

    International Nuclear Information System (INIS)

    Komine, Hideo; Yasuhara, Kazuya; Murakami, Satoshi

    2009-01-01

    A high-level radioactive waste disposal facility might be built in a coastal area in Japan from the viewpoint of feasible transportation of waste. Therefore, it is important to investigate the effects of seawater on a bentonite-based buffer. This study investigated the influence of seawater on self-sealing ability of three common sodium-types of bentonite by the laboratory experiment and chemical analysis. From the results of laboratory experiment, suitable specifications were defined for a bentonite-based buffer that can withstand the effects of seawater. Furthermore, mechanism on filtration of seawater components in highly compacted bentonite was discussed by the results of chemical analysis. (author)

  7. Physicochemical properties of soy protein isolate/carboxymethyl cellulose blend films crosslinked by Maillard reactions: Color, transparency and heat-sealing ability

    International Nuclear Information System (INIS)

    Su Junfeng; Yuan Xiaoyan; Huang Zhen; Wang Xinyu; Lu Xuzhen; Zhang Lidan; Wang Shengbao

    2012-01-01

    Soy protein isolate (SPI) films have many potential applications in the biomaterial field as surgical dressings for burns, films for reduction of wound inflammation, and facial masks. The appearance and the sealing ability are important physicochemical properties that greatly influence consumer acceptance of such protein-based films. The aim of the present work was to investigate the chemical structure and the physical properties associated with color, transparency and heat-sealing ability for SPI/carboxymethyl cellulose (CMC) blend films prepared by solution casting, with weight proportions 90/10, 80/20, 70/30 and 60/40. Fourier transform infra-red (FTIR) and solid-state 13 C nuclear magnetic resonance (NMR) spectra confirmed that Maillard reactions occurred between SPI and CMC. The Hunter color value (L, a, b) and transparency of films were affected by varying the proportions of SPI and CMC. With increasing degree of crosslinking of SPI and CMC, the yellow color of the films was diluted and transparency was improved. Peel strength and tensile strength measurements showed that the Maillard reactions had the main effect of enhancing the heat-sealing ability above the melting temperature. These results indicated that the structure and properties of SPI-based films could be modified and improved by blending with CMC. - Highlights: ► Maillard reactions occurred in SPI/CMC films. ► The color and transparency of SPI/CMC films were affected by Maillard reactions. ► Maillard reactions enhanced the heat-sealing ability of SPI/CMC films.

  8. Hydrodynamic perception in true seals (Phocidae) and eared seals (Otariidae).

    Science.gov (United States)

    Hanke, Wolf; Wieskotten, Sven; Marshall, Christopher; Dehnhardt, Guido

    2013-06-01

    Pinnipeds, that is true seals (Phocidae), eared seals (Otariidae), and walruses (Odobenidae), possess highly developed vibrissal systems for mechanoreception. They can use their vibrissae to detect and discriminate objects by direct touch. At least in Phocidae and Otariidae, the vibrissae can also be used to detect and analyse water movements. Here, we review what is known about this ability, known as hydrodynamic perception, in pinnipeds. Hydrodynamic perception in pinnipeds developed convergently to the hydrodynamic perception with the lateral line system in fish and the sensory hairs in crustaceans. So far two species of pinnipeds, the harbour seal (Phoca vitulina) representing the Phocidae and the California sea lion (Zalophus californianus) representing the Otariidae, have been studied for their ability to detect local water movements (dipole stimuli) and to follow hydrodynamic trails, that is the water movements left behind by objects that have passed by at an earlier point in time. Both species are highly sensitive to dipole stimuli and can follow hydrodynamic trails accurately. In the individuals tested, California sea lions were clearly more sensitive to dipole stimuli than harbour seals, and harbour seals showed a superior trail following ability as compared to California sea lions. Harbour seals have also been shown to derive additional information from hydrodynamic trails, such as motion direction, size and shape of the object that caused the trail (California sea lions have not yet been tested). The peculiar undulated shape of the harbour seals' vibrissae appears to play a crucial role in trail following, as it suppresses self-generated noise while the animal is swimming.

  9. A comparison of the sealing ability of various temporary restorative materials to seal the access cavity: An in vitro study

    Directory of Open Access Journals (Sweden)

    Aji Markose

    2016-01-01

    Full Text Available Introduction: In multiple-appointment root canal treatment, a temporary filling material is used to seal the access cavity between visits. The primary function of this material is to prevent the contamination of the root canal system by fluids, organic debris, and bacteria from the oral cavity. Material and Methods: A total of fifty extracted noncarious unrestored human maxillaryanterior teeth with intact crowns and roots were selected The canals were instrumented using stepback technique and sodium hypochlorite (3% and hydrogen peroxide (3% were used as irrigants for each specimen alternatively. The coronal two-thirds of each canal were flared using Gates-Glidden drills up to no. 3 size and obturated with Gutta-percha using zinc oxide-eugenol (ZnOE as sealer. The teeth were then randomly selected and divided into six groups out of which four were experimental groups and two control groups. The teeth were then immersed in 2% methylene blue dye solution for 3 days. All sealing materials and Gutta-percha were gently removed from the walls of the canal, and the entire circumference of the canal wall examined for dye penetration. Results: The lowest mean leakage was in the Fermit-N group followed by Cavit-W, ZnOE, intermediate restorative materials (IRM, and positive control. Conclusion: Fermit-N showed better sealing ability compared to cavit, ZnOE and IRM.

  10. Evaluation of apically extruded debris during removal of gutta-percha and ResilonTM using different instrumentation techniques

    Directory of Open Access Journals (Sweden)

    Pešić Dragana

    2018-01-01

    Full Text Available Background/Aim. Apical extrusion of material is considered as one of the very important factor for endodontic treatment success. Microorganisms, necrotic tissue, filling material and irrigants, which can be extruded apically during endodontic retreatment, may jeopardize the success of the therapy. The aim of this in vitro study was to quantitatively evaluate the amount of apically extruded debris during endodontic retreatment of teeth obturated with two different materials, using one hand and three rotary instrumentation techniques. Methods. Ninety-six extracted single-rooted teeth were endodontically treated and enlarged to size 40 using BioRaCe system, and then randomly divided into 8 groups of 12 specimens each. Half of the specimens were obturated with gutta-percha and AH Plus® sealer and another half with RealSeal SE system, using lateral condensation technique. Retreatment was performed using: Hedström files; ProFile rotary files; ProTaper Retreatment system and D-RaCe system. Apically extruded debris was collected in pre-weighed Eppendorf tubes and evaluated using an electronic microbalance. Data were analyzed statistically using t-test and analysis of variance. Results. In the AH Plus/gutta-percha group, all tested rotary instruments gave significantly less extruded debris compared with Hedström files (p < 0.05. In theRealSeal group, there was significant difference between DRaCe and Hedström instruments (p < 0.05. Conclusion. All retreatment techniques resulted in apical extrusion. DRaCe system produced significantly less extruded debris compared to hand files. No significant difference was found when comparing two instruments specially designed for retreatment: D-RaCe and ProTaper systems.

  11. Sealing ability and thermal diffusivity of cavity lining materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Prabhakar A

    2008-10-01

    Full Text Available Aims: The purpose of this study was to evaluate and compare the sealing ability and the thermal insulating capability of four different cavity lining materials. Materials and Methods: Forty noncarious human mandibular second premolars that were extracted for orthodontic treatment were collected, cleaned, and stored in distilled water. These premolars were randomly divided into four groups of ten teeth each for treatment with the different cavity lining materials. Group I teeth were treated with cavity varnish, group II teeth with amorphous calcium phosphate (ACP, group III teeth with dentin bonding agent, and group IV teeth with resin-modified glass ionomer cement (RMGIC. Electrical resistance and the difference in the time-temperature curve of the external surface and the pulp side [A D -A P ] of each tooth following heat and cold application for 120 s were measured before and after cavity lining placement to determine the sealing ability and thermal insulating property, respectively. Data collected were subjected to statistical analysis. For paired data, paired t-test and Wilcoxon′s signed rank test were used. One-way ANOVA was used for comparisons between multiple groups and the Mann-Whitney U test for comparisons between pairs. Results: The mean difference in electrical resistance (in KΩ of different cavity lining materials were as follows: group I = +3.53, group II = −1.00, group III = +20.43, and group IV = +11.44. The mean differences in the area (A D -A P under the time-temperature curve following heat application were as follows: group I = 6.6 mm 2 , group II = 15.3 mm 2 , group III = 130.5 mm 2 , and group IV = 412.0 mm 2 . The mean differences in the area (A D -A P under the time-temperature curve following cold application were as follows: group I = 24.5 mm 2 , group II = 3.2 mm 2 , group III = 314.9 mm 2 , and group IV = 480.5 mm 2 . Conclusion: Dentin bonding agent and RMGIC provided effective sealing of the dentinal tubules

  12. Conservative treatment of immature teeth with apical periodontitis using triple antibiotic paste disinfection

    Directory of Open Access Journals (Sweden)

    Hsin-Ju Wang

    2016-06-01

    Full Text Available The purpose of this report is to present conservative treatment for two immature premolars with apical periodontitis. A triple antibiotic paste was used to disinfect the root canal systems for revascularization. In both cases, residual vital pulp tissue was noted in the root canal system after the opening of each premolar. The canals in both cases were irrigated with copious sodium hypochlorite solution and medicated with a paste consisting of ciprofloxacin, metronidazole, and minocycline. The teeth were sealed with mineral trioxide aggregate and restored with composite resin. There were satisfactory outcomes after 18 months. The patients were asymptomatic, with radiographic evidence of complete resolution of radiolucency, continual thickening of dentinal walls, apical closure, and increased root length.

  13. SEALING SIMULATED LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  14. Ex vivo analysis of marginal apical sealing ability of a mta Fillapex® = Avaliação ex vivo do selamento apical marginal do mta Fillapex®

    Directory of Open Access Journals (Sweden)

    Pinto, Nilce Mendes Faria

    2015-01-01

    Full Text Available Objetivos: O presente estudo teve como objetivo avaliar ex vivo a capacidade de selamento apical do cimento endodôntico MTA FILLAPEX® comparando com Sealapex, Pulp Canal Sealer e AH26. Metodologia: Foi avaliada a capacidade deste cimento em prevenir a infiltração de uma cultura de Enterococcus Faecalis através da obturação do canal radicular. Foram utilizados 48 dentes unirradiculados de humanos, que depois de instrumentados e obturados pela técnica da condensação vertical da guta-percha aquecida, foram divididos em 4 grupos experimentais (n=10, um grupo controle positivo (n=4, ou um grupo controle negativo (n=4. A inoculação microbiana foi realizada a cada três dias, sempre com cultura de 24 horas, durante um período de 60 dias. Os dados foram tabulados e analisados estatisticamente por Análise de Sobrevivência, onde se comparou o desempenho dos quatro cimentos, utilizando o Teste Log-Rank Resultados: Os resultados mostraram que o grupo obturado com MTA FILLAPEX®, apresentou todas as amostras infiltradas. Os cimentos Sealapex e Pulp Canal Sealer apresentaram 90 e 80 e 30% de amostras infiltradas respectivamente. O cimento AH26 foi significativamente mais eficiente em retardar a infiltração, embora com 30% das amostras infiltradas. Conclusão: O cimento MTA FILLAPEX® quando comparado aos outros cimentos avaliados, apresentou a maior infiltração frente a uma cultura de Enterococcus Faecalis

  15. Absorbable Suture as an Apical Matrix in Single Visit Apexification with Mineral Trioxide Aggregate

    Directory of Open Access Journals (Sweden)

    Ayush Goyal

    2016-01-01

    Full Text Available Several procedures have been recommended to induce the root end barrier formation in teeth with open apices. Conventional treatment for such cases will require many appointments with an average duration of 12.9 months. During this period, the root canal is susceptible to reinfection from around the provisional restoration, which may promote apical periodontitis and arrest of apical repair. Mineral trioxide aggregate (MTA has been successfully used for one visit apexification wherein the root canal can be obturated within 24 hours after placement of MTA. Using a matrix prior to the placement of MTA avoids its extrusion, reduces leakage in the sealing material, and allows favorable response of the periapical tissues. This report presents a case of apexification where an absorbable suture was used as an apical matrix. Use of an absorbable suture circumvents all the problems associated with other conventional materials. Conclusion. Placement of the matrix made from the suture material is predictable and is easily positioned at the apex and the length can be adjusted as required. 10-month follow-up of the case shows resorbed matrix and bone healing in the periapical region. The patient was asymptomatic during the whole follow-up period and tooth exhibited mobility within physiologic limits and was functioning normally.

  16. Absorbable Suture as an Apical Matrix in Single Visit Apexification with Mineral Trioxide Aggregate.

    Science.gov (United States)

    Goyal, Ayush; Nikhil, Vineeta; Jha, Padmanabh

    2016-01-01

    Several procedures have been recommended to induce the root end barrier formation in teeth with open apices. Conventional treatment for such cases will require many appointments with an average duration of 12.9 months. During this period, the root canal is susceptible to reinfection from around the provisional restoration, which may promote apical periodontitis and arrest of apical repair. Mineral trioxide aggregate (MTA) has been successfully used for one visit apexification wherein the root canal can be obturated within 24 hours after placement of MTA. Using a matrix prior to the placement of MTA avoids its extrusion, reduces leakage in the sealing material, and allows favorable response of the periapical tissues. This report presents a case of apexification where an absorbable suture was used as an apical matrix. Use of an absorbable suture circumvents all the problems associated with other conventional materials. Conclusion . Placement of the matrix made from the suture material is predictable and is easily positioned at the apex and the length can be adjusted as required. 10-month follow-up of the case shows resorbed matrix and bone healing in the periapical region. The patient was asymptomatic during the whole follow-up period and tooth exhibited mobility within physiologic limits and was functioning normally.

  17. Tolerance of brightness and contrast adjustments on chronic apical abscess and apical granuloma interpretation

    Science.gov (United States)

    Purnamasari, L.; Iskandar, H. H. B.; Makes, B. N.

    2017-08-01

    In digitized radiography techniques, adjusting the image enhancement can improve the subjective image quality by optimizing the brightness and contrast for diagnostic needs. To determine the value range of image enhancement (brightness and contrast) on chronic apical abscess and apical granuloma interpretation. 30 periapical radiographs that diagnosed chronic apical abscess and 30 that diagnosed apical granuloma were adjusted by changing brightness and contrast values. The value range of brightness and contrast adjustment that can be tolerated in radiographic interpretations of chronic apical abscess and apical granuloma spans from -10 to +10. Brightness and contrast adjustments on digital radiographs do not affect the radiographic interpretation of chronic apical abscess and apical granuloma if conducted within the value range.

  18. Clinical results with two different methods of root-end preparation and filling in apical surgery: mineral trioxide aggregate and adhesive resin composite

    DEFF Research Database (Denmark)

    von Arx, Thomas; Hanni, Stefan; Jensen, Simon Storgaard

    2010-01-01

    The aim of apical surgery is to hermetically seal the root canal system after root-end resection, thereby enabling periradicular healing. The objective of this nonrandomized prospective clinical study was to report results of 2 different root-end preparation and filling methods, ie, mineral triox...

  19. Hermetizing ability of the new obturating material for root canals «Real Seal» with «Resilon» technology

    Directory of Open Access Journals (Sweden)

    Makedonova Y.A.

    2012-03-01

    Full Text Available Simple, reliable and predictable obturation of root canals side by side with their cleaning and forming is an essential part of the endodontic treatment. The aim of this research is investigation of obturation density of root canals. Canals filled by means of lateral condensation of the new obturative system «Real Seal/Resilon» and by means of traditional method of canals obturation with the help of gutta-percha and sealer АН-plus. The results of the research proved a ligher hermetizing ability of the new experimental material «Real Seal» in comparison with obturation by means of gutta-percha pins. The obtained data reflects an objective picture and can be applied as a unique quality monitoring obturation of root canals.

  20. Evaluation of the Sealing Ability of Three Obturation Techniques Using a Glucose Leakage Test

    Directory of Open Access Journals (Sweden)

    Katarzyna Olczak

    2017-01-01

    Full Text Available The aim of this study was to evaluate the sealing ability of three different canal filling techniques. Sixty-four roots of extracted human maxillary anterior teeth were prepared using ProTaper® rotary instruments. The specimens were then randomly divided into 3 experimental groups (n=16 and 2 control groups (n=8. The root canals were filled using cold lateral compaction (CLC group, continuous wave condensation technique using the Elements Obturation Unit® (EOU group, and ProTaper obturators (PT group. For the negative control group, 8 roots were filled using lateral compaction as in the CLC group, and the teeth were covered twice with a layer of nail varnish (NCG group. Another 8 roots were filled using lateral compaction, but without sealer, and these were used as the positive control (PCG group. A glucose leakage model was used for quantitative evaluation of microleakage for 24 hours and 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, and 12 weeks. No significant difference in the cumulative amount of leakage was found between the three experimental groups at all observation times. The lateral condensation of cold gutta-percha can guarantee a similar seal of canal fillings as can be achieved by using thermal methods, in the round canals.

  1. Apical cap

    International Nuclear Information System (INIS)

    McLoud, T.C.; Isler, R.J.; Novelline, R.A.; Putman, C.E.; Simeone, J.; Stark, P.

    1981-01-01

    Apical caps, either unilateral or bilateral, are a common feature of advancing age and are usually the result of subpleural scarring unassociated with other diseases. Pancoast (superior sulcus) tumors are a well recognized cause of unilateral asymmetric apical density. Other lesions arising in the lung, pleura, or extrapleural space may produce unilateral or bilateral apical caps. These include: (1) inflammatory: tuberculosis and extrapleural abscesses extending from the neck; (2) post radiation fibrosis after mantle therapy for Hodgkin disease or supraclavicular radiation in the treatment of breast carcinoma; (3) neoplasm: lymphoma extending from the neck or mediastinum, superior sulcus bronchogenic carcinoma, and metastases; (4) traumatic: extrapleural dissection of blood from a ruptured aorta, fractures of the ribs or spine, or hemorrhage due to subclavian line placement; (5) vascular: coarctation of the aorta with dilated collaterals over the apex, fistula between the subclavian artery and vein; and (6) miscellaneous: mediastinal lipomatosis with subcostal fat extending over the apices

  2. Apical Closure in Apexification: A Review and Case Report of Apexification Treatment of an Immature Permanent Tooth with Biodentine.

    Science.gov (United States)

    Vidal, Karla; Martin, Gabriela; Lozano, Oscar; Salas, Marco; Trigueros, Jaime; Aguilar, Gabriel

    2016-05-01

    Materials such as calcium hydroxide paste and mineral trioxide aggregate are used in apexification treatment of immature permanent teeth, but the search for improved materials with higher characteristics of biocompatibility results in different materials. Biodentine is a tricalcium silicate cement that possesses adequate handling characteristics and acceptable mechanical and bioactivity properties. This report describes the case of a 9-year-old boy who was referred to the Department of Dental Clinic of Querétaro Autonomous University of Mexico. One month prior the patient had suffered a dental trauma of his upper left central incisor and had been treated by another dentist. The clinical diagnosis was previously initiated therapy and symptomatic apical periodontitis. The treatment was apexification with Biodentine. At follow-ups performed at 3, 6, and 18 months after treatment the tooth was asymptomatic. The cone-beam computed tomography scan at 18-month postoperative follow-up revealed continuity of periodontal ligament space, absence of periapical rarefactions, and a thin layer of calcified tissue formed apical to the Biodentine barrier. On the basis of sealing ability and biocompatibility, apexification treatment with Biodentine was applied in the present case report. The favorable clinical and radiographic outcome in this case demonstrated that Biodentine may be an efficient alternative to the conventional apexification materials. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Sealing ability of mineral trioxide aggregate and Portland cement for furcal perforation repair: a protein leakage study.

    Science.gov (United States)

    Shahi, Shahriar; Rahimi, Saeed; Hasan, Maryam; Shiezadeh, Vahab; Abdolrahimi, Majid

    2009-12-01

    The purpose of this study was to compare the sealing ability of gray mineral trioxide aggregate (GMTA), white MTA (WMTA), and both white and gray Portland cement as furcation perforation repair materials. A total of 120 human mandibular first molars were used. After root canal obturation and preparation of furcal perforations the specimens were randomly divided into four groups of 25 teeth each. In groups A, B, C, and D furcation perforations were filled with WMTA, GMTA, white Portland cement, and type II Portland cement, respectively. Ten teeth were used as positive controls with no filling materials in the perforations and 10 teeth with complete coverage with two layers of nail varnish were used as negative controls. A protein leakage model utilizing 22% bovine serum albumin (BSA) was used for evaluation. Leakage was noted when color conversion of the protein reagent was observed. The controls behaved as expected. Leakage was found in the samples from group A (WMTA), group B (GMTA), and in the two other groups (white and gray Portland cement). There were no statistically significant differences between GMTA and WMTA or white and gray Portland cement, but significant differences were observed between the MTA groups and the Portland cement groups. It was concluded that Portland cements have better sealing ability than MTA, and can be recommended for repair of furcation perforation if the present results are supported by other in vivo and in vitro studies.

  4. Seals and sealing handbook

    CERN Document Server

    Flitney, Robert K

    2014-01-01

    Seals and Sealing Handbook, 6th Edition provides comprehensive coverage of sealing technology, bringing together information on all aspects of this area to enable you to make the right sealing choice. This includes detailed coverage on the seals applicable to static, rotary and reciprocating applications, the best materials to use in your sealing systems, and the legislature and regulations that may impact your sealing choices. Updated in line with current trends this updated reference provides the theory necessary for you to select the most appropriate seals for the job and with its 'Failur

  5. Sealing properties of cement-based grout materials used in the rock sealing project

    Energy Technology Data Exchange (ETDEWEB)

    Onofrei, M; Gray, M N; Pusch, R; Boergesson, L; Karnland, O; Shenton, B; Walker, B

    1993-12-01

    The Task Force on Sealing Materials and Techniques of the Stripa Project recommended that work be undertaken to study the sealing properties of cement-based grout materials. A new class of cement-based grouts (high-performance grouts) with the ability to penetrate and seal fine fractures in granite was investigated. The materials were selected for their small mean particle size and the ability to be made fluid by a superplasticizer at low water/cementitious-materials ratios. The fundamental physical and chemical properties (such as the particle size and chemical composition) of the materials were evaluated. The rheological properties of freshly mixed grouts, which control the workability of the grouts, were determined together with the properties of hardened materials, which largely control the long-term performance (longevity) of the materials in repository settings. The materials selected were shown to remain gel-like during the setting period, and so the grouts may be expected to remain largely homogenous during and after injection into the rock without separating into solid and liquid phases. The hydraulic conductivity and strength of hardened grouts were determined. The microstructure of the bulk grouts was characterized by a high degree of homogeneity with extremely fine porosity. The low hydraulic conductivity and good mechanical properties are consistent with the extremely fine porosity. The ability of the fractured grouts to self-seal was also observed in tests in which the hydraulic conductivity of recompacted granulated grouts was determined. The laboratory tests were carried out in parallel with investigations of the in situ performance of the materials and with the development of geochemical and theoretical models for cement-based grout longevity. (author). 56 refs., 15 tabs., 98 figs.

  6. Sealing properties of cement-based grout materials used in the rock sealing project

    International Nuclear Information System (INIS)

    Onofrei, M.; Gray, M.N.; Pusch, R.; Boergesson, L.; Karnland, O.; Shenton, B.; Walker, B.

    1993-12-01

    The Task Force on Sealing Materials and Techniques of the Stripa Project recommended that work be undertaken to study the sealing properties of cement-based grout materials. A new class of cement-based grouts (high-performance grouts) with the ability to penetrate and seal fine fractures in granite was investigated. The materials were selected for their small mean particle size and the ability to be made fluid by a superplasticizer at low water/cementitious-materials ratios. The fundamental physical and chemical properties (such as the particle size and chemical composition) of the materials were evaluated. The rheological properties of freshly mixed grouts, which control the workability of the grouts, were determined together with the properties of hardened materials, which largely control the long-term performance (longevity) of the materials in repository settings. The materials selected were shown to remain gel-like during the setting period, and so the grouts may be expected to remain largely homogenous during and after injection into the rock without separating into solid and liquid phases. The hydraulic conductivity and strength of hardened grouts were determined. The microstructure of the bulk grouts was characterized by a high degree of homogeneity with extremely fine porosity. The low hydraulic conductivity and good mechanical properties are consistent with the extremely fine porosity. The ability of the fractured grouts to self-seal was also observed in tests in which the hydraulic conductivity of recompacted granulated grouts was determined. The laboratory tests were carried out in parallel with investigations of the in situ performance of the materials and with the development of geochemical and theoretical models for cement-based grout longevity. (author). 56 refs., 15 tabs., 98 figs

  7. Palatal radicular groove: Clinical implications of early diagnosis and surgical sealing

    Directory of Open Access Journals (Sweden)

    P Corrêa-Faria

    2011-01-01

    Full Text Available Palatal radicular groove is a discreet alteration in tooth morphology, characterized by an invagination that begins near the cingulum of the tooth and moves in an apical direction. Clinically, palatal radicular groove may be associated with periodontal and/or endodontic problems. This paper describes a clinical case of a young patient with palatal radicular groove with no signs of periodontal disease or endodontic impairment. An early diagnosis was made and treatment consisted of surgical sealing of the defect. After a 2-year period, reexaminations demonstrated adequate hygiene, maintenance of tooth vitality and periodontal health. The early diagnosis and sealing of the groove observed surgically made the root surface smooth, avoiding subgingival bacterial plaque buildup, and preventing possible periodontal and/or pulp impairment stemming from the defect.

  8. Apical instrumentation in endodontic therapy

    Directory of Open Access Journals (Sweden)

    Kurniasri Darliana

    2007-07-01

    Full Text Available Cleaning and shaping of the root canal as the foundation for successful endodontic therapy. Cleaning of the root canal as the removal of all the contents of the root canal systems before and during shaping. Mechanical cleaning as the most important part of the root canal therapy. Instrumentation of the apical region has long been considered to be an essential component in the cleaning and shaping process. The apical area as the critical zone for instrumentation. The apical portion of the root canal system can retain microorganisms that could potentially cause periradicular inflammation. The nickel-titanium rotary instrumentation system to facilitate the cleaning and shaping process. Larger instrumentation sizes not only allow proper irrigation but also significantly decrease remaining bacteria in the canal system. How the larger apical sizes preparation must be achieved to clinical success. This paper will describe the major factors impacting the selection of final apical size, the factors are the anatomy of the apical constriction, root canal diameter, apical instrumentation, and bacteria in dentin tubuli.

  9. Spray sealing: A breakthrough in integral fuel tank sealing technology

    Science.gov (United States)

    Richardson, Martin D.; Zadarnowski, J. H.

    1989-11-01

    In a continuing effort to increase readiness, a new approach to sealing integral fuel tanks is being developed. The technique seals potential leak sources by spraying elastomeric materials inside the tank cavity. Laboratory evaluations project an increase in aircraft supportability and reliability, an improved maintainability, decreasing acquisition and life cycle costs. Increased usable fuel volume and lower weight than conventional bladders improve performance. Concept feasibility was demonstrated on sub-scale aircraft fuel tanks. Materials were selected by testing sprayable elastomers in a fuel tank environment. Chemical stability, mechanical properties, and dynamic durability of the elastomer are being evaluated at the laboratory level and in sub-scale and full scale aircraft component fatigue tests. The self sealing capability of sprayable materials is also under development. Ballistic tests show an improved aircraft survivability, due in part to the elastomer's mechanical properties and its ability to damp vibrations. New application equipment, system removal, and repair methods are being investigated.

  10. Expression of Podoplanin in the Mouse Tooth Germ and Apical Bud Cells

    Science.gov (United States)

    Sawa, Yoshihiko; Iwasawa, Kana; Ishikawa, Hiroyuki

    2008-01-01

    This study was designed to investigate the distribution of cells expressing podoplanin in the mouse tooth bud. Podoplanin expression was detected in enamel epithelia of the cervical loop at cell-cell contacts strongly, and weakly on the loosely aggregated stellate reticulum in the center and the neighboring stratum intermedium. Odontoblasts exhibited intense podoplanin expression at the junction with predentin while no expression was detected in the enamel organ containing ameloblasts. These results suggest that proliferating inner and outer enamel epithelia express podoplanin but that the expression is suppressed in the differentiated epithelia containing ameloblasts. On the other hand the podoplanin expression occurs in the differentiating odontoblasts and the expression is sustained in differentiated odontoblasts, indicating that odontoblasts have the strong ability to express podoplanin. In cultured apical bud cells podoplanin was detected at cell-cell contacts. In real-time PCR analysis the amount of podoplanin mRNA of the apical buds was 2-fold compared with the amount of kidney used as a positive control. These findings indicate that apical bud cells have the strong ability to express the podoplanin gene. Podoplanin is a mucin-type glycoprotein negatively charged by extensive O-glycosylation and a high content of sialic acid, which expresses the adhesive property. The podoplanin may contribute to form odontoblastic fiber or function as the anchorage to the tooth development and in proliferating epithelial cells of cervical loop and apical bud. PMID:18989465

  11. Management of immature teeth with apical infections using mineral trioxide aggregate

    Directory of Open Access Journals (Sweden)

    Sivakumar Nuvvula

    2010-01-01

    Full Text Available Traumatic injuries to the young permanent teeth lead to devitalization of the pulp with concomitant arrest in further development of the immature root of the involved tooth. Hermetic seal of the root canal system during obturation is not possible in such cases, due to the lack of an apical constriction. The traditional management technique in such cases has been apexification involving induction of a calcific barrier at the apex using calcium hydroxide, which in turn facilitates obturation of the root canal. However this becomes complicated when there is persistent infection leading to periapical changes. This case report describes the use of mineral trioxide aggregate (MTA for management of a periapically compromised immature tooth.

  12. Sealing of boreholes using natural, compatible materials: Granular salt

    International Nuclear Information System (INIS)

    Finley, R.E.; Zeuch, D.H.; Stormont, J.C.; Daemen, J.J.K.

    1994-01-01

    Granular salt can be used to construct high performance permanent seals in boreholes which penetrate rock salt formations. These seals are described as seal systems comprised of the host rock, the seal material, and the seal rock interface. The performance of these seal systems is defined by the complex interactions between these seal system components through time. The interactions are largely driven by the creep of the host formation applying boundary stress on the seal forcing host rock permeability with time. The immediate permeability of these seals is dependent on the emplaced density. Laboratory test results suggest that careful emplacement techniques could results in immediate seal system permeability on the order of 10 -16 m 2 to 10 -18 m 2 (10 -4 darcy to 10 -6 ). The visco-plastic behavior of the host rock coupled with the granular salts ability to ''heal'' or consolidate make granular salt an ideal sealing material for boreholes whose permanent sealing is required

  13. Virus interaction with the apical junctional complex.

    Science.gov (United States)

    Gonzalez-Mariscal, Lorenza; Garay, Erika; Lechuga, Susana

    2009-01-01

    In order to infect pathogens must breach the epithelial barriers that separate the organism from the external environment or that cover the internal cavities and ducts of the body. Epithelia seal the passage through the paracellular pathway with the apical junctional complex integrated by tight and adherens junctions. In this review we describe how viruses like coxsackie, swine vesicular disease virus, adenovirus, reovirus, feline calcivirus, herpes viruses 1 and 2, pseudorabies, bovine herpes virus 1, poliovirus and hepatitis C use as cellular receptors integral proteins present at the AJC of epithelial cells. Interaction with these proteins contributes in a significant manner in defining the particular tropism of each virus. Besides these proteins, viruses exhibit a wide range of cellular co-receptors among which proteins present in the basolateral cell surface like integrins are often found. Therefore targeting proteins of the AJC constitutes a strategy that might allow viruses to bypass the physical barrier that blocks their access to receptors expressed on the basolateral surface of epithelial cells.

  14. A hybrid floating brush seal (HFBS) for improved sealing and wear performance in turbomachinery applications

    Science.gov (United States)

    Lattime, Scott Byran

    A conceptually new type of seal has been developed for gas turbine applications which dramatically reduces wear and leakage associated with current labyrinth and brush seal technologies. The Hybrid Floating Brush Seal (HFBS) combines brush seal and film riding face seal technologies to create a hybrid seal that allows both axial and radial excursions of the sealed shaft, while simultaneously eliminating interface surface speeds (friction and heat) between the rotor and the brush material that characterize standard brush seal technology. A simple test rig was designed to evaluate feasibility of the HFBS under relatively low pressures and rotational speeds (50psig, 5krpm). A second test stand was created to study the effects of centrifugal force on bristle deflection. A third test facility was constructed for prototype development and extensive room temperature testing at moderate pressures and fairly high rotational speeds (100psig, 40krpm). This test rig also allowed the evaluation of the HFBS during axial movement of a rotating shaft. An analytical model to predict the effects of centrifugal force on the bristles of a rotating brush seal was developed. Room temperature analysis of the HFBS proved successful for relatively high operating rotational velocities at moderate pressures with very acceptable leakage rates for gas turbine engines. Brush seals were able to track rotor speeds up to 24krpm while maintaining sealing integrity. The HFBS's ability to function under axial shaft displacement and synchronous dynamic radial loading was also proven successful. Hydrodynamic performance of the face seal was proven to provide adequate stiffness and load carrying capacity to keep the brush seal from contacting the face seal at pressure drops across the brush of up to 100psi. Leakage performance over standard brush seal and labyrinth technology was quite dramatic. The HFBS showed its sealing advantage using much higher radial interference between the rotor and the bristle

  15. Systemic antibiotics for symptomatic apical periodontitis and acute apical abscess in adults.

    Science.gov (United States)

    Cope, Anwen; Francis, Nick; Wood, Fiona; Mann, Mala K; Chestnutt, Ivor G

    2014-06-26

    Dental pain can have a considerable detrimental effect on an individual's quality of life. Symptomatic apical periodontitis and acute apical abscess are common causes of dental pain and arise from an inflamed or necrotic dental pulp, or infection of the pulpless root canal system. Clinical guidelines recommend that the first-line treatment for teeth with symptomatic apical periodontitis or an acute apical abscess should be removal of the source of inflammation or infection by local, operative measures, and that systemic antibiotics are currently only recommended for situations where there is evidence of spreading infection (cellulitis, lymph node involvement, diffuse swelling) or systemic involvement (fever, malaise). Despite this, there is evidence that dentists continue to prescribe antibiotics for these conditions. There is concern that this could contribute to the development of antibiotic-resistant bacterial colonies both within the individual and within the community as a whole. To evaluate the effects of systemic antibiotics provided with or without surgical intervention (such as extraction, incision and drainage of a swelling or endodontic treatment), with or without analgesics, for symptomatic apical periodontitis or acute apical abscess in adults. We searched the following electronic databases: Cochrane Oral Health Group's Trials Register (to 1 October 2013); Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 9); MEDLINE via OVID (1946 to 1 October 2013); EMBASE via OVID (1980 to 1 October 2013) and CINAHL via EBSCO (1980 to 1 October 2013). We searched the World Health Organization (WHO) International Trials Registry Platform and the US National Institutes of Health Trials Registry (ClinicalTrials.gov) on 1 October 2013 to identify ongoing trials. We searched for grey literature using OpenGrey (to 1 October 2013) and ZETOC Conference Proceedings (1993 to 1 October 2013). We placed no restrictions on the language or date of

  16. Compliant Glass Seals for SOFC Stacks

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Yeong -Shyung [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Choi, Jung-Pyung [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xu, Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephens, Elizabeth V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Koeppel, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stevenson, Jeffry W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lara-Curzio, Edgar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-04-30

    This report summarizes results from experimental and modeling studies performed by participants in the Solid-State Energy Conversion Alliance (SECA) Core Technology Program, which indicate that compliant glass-based seals offer a number of potential advantages over conventional seals based on de-vitrifying glasses, including reduced stresses during stack operation and thermal cycling, and the ability to heal micro-damage induced during thermal cycling. The properties and composition of glasses developed and/or investigated in these studies are reported, along with results from long-term (up to 5,800h) evaluations of seals based on a compliant glass containing ceramic particles or ceramic fibers.

  17. Effect of apical clearing technique on the treatment outcome of teeth with asymptomatic apical periodontitis: A randomized clinical trial

    OpenAIRE

    Priya Mittal; Ajay Logani; Naseem Shah; R M Pandey

    2016-01-01

    Aim: This study aims to compare the periapical healing of teeth with asymptomatic apical periodontitis treated either by conventional apical preparation (CAP) or apical clearing technique (ACT). Materials and Methods: T wenty subjects with bilateral nonvital similar teeth exhibiting comparable periapical index (PAI) score were enrolled and randomly allocated. Group I (CAP, n = 20): Apical preparation three sizes greater (master apical file [MAF]) than the first binding file at the establis...

  18. Effect of different dye solutions on the evaluation of the sealing ability of mineral trioxide aggregate Efeito de diferentes soluções corantes na avaliação da capacidade seladora do agregado de trióxido mineral

    Directory of Open Access Journals (Sweden)

    Mário Tanomaru Filho

    2005-06-01

    Full Text Available Alkaline materials have shown incompatibility with methylene blue dye in leakage experiments. The goal of the present study was to analyze the effect of different dyes on the evaluation of the apical sealing ability of Mineral Trioxide Aggregate root-end fillings. Fifty-six extracted human canines were submitted to root canal instrumentation and obturation. After apical resection, retrograde cavities were prepared and teeth were randomly divided into four experimental (n = 13 and two control groups (n = 2. The following root-end filling materials were used: groups 1 and 2 - Pro Root MTA (Dentsply, groups 3 and 4 - zinc oxide-eugenol cement (ZOE. Teeth in groups 1 and 3 were immersed in 2% methylene blue solution, while teeth in groups 2 and 4 were immersed in 0.2% rhodamine B in a reduced pressure environment for 48 hours. Teeth were then longitudinally sectioned and leakage was evaluated. Results were submitted to statistical analysis (ANOVA and Tukey's test. Group 1 presented the least leakage (p Tem sido demonstrada a incompatibilidade de materiais alcalinos com a solução corante de azul de metileno utilizada em testes de infiltração marginal. O objetivo do presente estudo foi analisar a influência de diferentes soluções corantes na avaliação do selamento apical proporcionado pelo agregado de trióxido mineral. Cinqüenta e seis caninos humanos extraídos tiveram seus canais radiculares instrumentados e obturados. Após a secção da porção apical, cavidades retrógradas foram preparadas e os dentes divididos aleatoriamente em quatro grupos experimentais (n = 13 e dois controles (n = 2. Foram utilizados os seguintes materiais retrobturadores: grupos 1 e 2 - Pro Root MTA (Dentsply; grupos 3 e 4 - cimento de óxido de zinco e eugenol (OZE. Em seguida, os dentes dos grupos 1 e 3 foram imersos em solução de Azul de Metileno a 2% e dos grupos 2 e 4 em solução de Rodamina B a 0,2% por 48 horas em ambiente com vácuo. Decorrido este

  19. Persistent extraradicular infection in root-filled asymptomatic human tooth: scanning electron microscopic analysis and microbial investigation after apical microsurgery.

    Science.gov (United States)

    Signoretti, Fernanda G C; Endo, Marcos S; Gomes, Brenda P F A; Montagner, Francisco; Tosello, Fernanda B; Jacinto, Rogério C

    2011-12-01

    Procedural accidents have a negative effect on healing and might contribute to the persistence of infections in inaccessible apical areas, requiring surgical intervention. This report describes a case of persistent apical periodontitis of a lower left first molar associated with the sinus tract and a periapical lesion that required nonsurgical endodontic retreatment and apical surgery for resolution. The tooth had received endodontic treatment 3 years ago and had to be retreated using the crown-down technique with chemical auxiliary substance (2% chlorhexidine gel), foramen patency, and enlargement and was filled in a single appointment. The occlusal access cavity was immediately restored with composite resin. After 1 month, it could be observed that the sinus tract persisted and, radiographically, the lesion remained unaltered. Therefore, endodontic microsurgery was indicated. Apical microsurgery was performed under magnification with the use of a dental operating microscope including apicectomy, root end with ultrasound, and sealing with mineral trioxide aggregate. A microbiological sample was collected from the apical lesion. The resected distal root apex was observed by scanning electron microscopy. The following species were detected: Actinomyces naeslundii and Actinomyces meyeri, Propionibacterium propionicum, Clostridium botullinum, Parvimonas micra, and Bacteroides ureolyticus; scanning electron microscopic analysis revealed bacterial biofilm surrounding the apical foramen and external radicular surface. Gutta-percha overfilling at the apex because of a zip caused during initial endodontic treatment could be observed. A 6-month follow-up showed apparent radiographic periapical healing, which progressed after 24 months. Gram-positive anaerobic bacteria and extraradicular biofilm seem to participate in the maintenance of persistent periapical pathology, and endodontic retreatment followed by periapical microsurgery proved to be a successful alternative in the

  20. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software.

    Science.gov (United States)

    Giannastasio, Daiana; Rosa, Ricardo Abreu da; Peres, Bernardo Urbanetto; Barreto, Mirela Sangoi; Dotto, Gustavo Nogara; Kuga, Milton Carlos; Pereira, Jefferson Ricardo; Só, Marcus Vinícius Reis

    2013-01-01

    This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.

  1. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software

    Science.gov (United States)

    GIANNASTASIO, Daiana; da ROSA, Ricardo Abreu; PERES, Bernardo Urbanetto; BARRETO, Mirela Sangoi; DOTTO, Gustavo Nogara; KUGA, Milton Carlos; PEREIRA, Jefferson Ricardo; SÓ, Marcus Vinícius Reis

    2013-01-01

    Objective This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Material and Methods Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. Results The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Conclusion Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop. PMID:24212994

  2. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software

    Directory of Open Access Journals (Sweden)

    Daiana Giannastasio

    2013-09-01

    Full Text Available OBJECTIVE: This study has two aims: 1 to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2 to compare, with Adobe Photoshop, the ability of a new software (Regeemy in superposing and subtracting images. MATERIAL AND METHODS: Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection. Canals were prepared up to F2 (ProTaper and 24.04 (Wizard CD Plus instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. RESULTS: The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05. ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05. CONCLUSION: Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.

  3. Acoustic resonance spectroscopy intrinsic seals

    International Nuclear Information System (INIS)

    Olinger, C.T.; Burr, T.; Vnuk, D.R.

    1994-01-01

    We have begun to quantify the ability of acoustic resonance spectroscopy (ARS) to detect the removal and replacement of the lid of a simulated special nuclear materials drum. Conceptually, the acoustic spectrum of a container establishcs a baseline fingerprint, which we refer to as an intrinsic seal, for the container. Simply removing and replacing the lid changes some of the resonant frequencies because it is impossible to exactly duplicate all of the stress patterns between the lid and container. Preliminary qualitative results suggested that the ARS intrinsic seal could discriminate between cases where a lid has or has not been removed. The present work is directed at quantifying the utility of the ARS intrinsic seal technique, including the technique's sensitivity to ''nuisance'' effects, such as temperature swings, movement of the container, and placement of the transducers. These early quantitative tests support the potential of the ARS intrinsic seal application, but also reveal a possible sensitivity to nuisance effects that could limit environments or conditions under which the technique is effective

  4. Seals and sealing handbook

    CERN Document Server

    Flitney, Robert K

    2007-01-01

    Wherever machinery operates there will be seals of some kind ensuring that the machine remains lubricated, the fluid being pumped does not leak, or the gas does not enter the atmosphere. Seals are ubiquitous, in industry, the home, transport and many other places. This 5th edition of a long-established title covers all types of seal by application: static, rotary, reciprocating etc. The book bears little resemblance to its predecessors, and Robert Flitney has re-planned and re-written every aspect of the subject. No engineer, designer or manufacturer of seals can afford to be without this uniq

  5. Pulp Revascularization on Permanent Teeth with Open Apices in a Middle-aged Patient.

    Science.gov (United States)

    Wang, Yu; Zhu, Xiaofei; Zhang, Chengfei

    2015-09-01

    Pulp revascularization is a promising procedure for the treatment of adolescents' immature permanent teeth with necrotic pulp and/or apical periodontitis. However, the ability to successfully perform pulp revascularization in a middle-aged patient remains unclear. A 39-year-old woman was referred for treatment of teeth #20 and #29 with necrotic pulp, extensive periapical radiolucencies, and incomplete apices. Pulp revascularization procedures were attempted, including root canal debridement, triple antibiotic paste medication, and platelet-rich plasma transplantation to act as a scaffold. Periapical radiographic and cone-beam computed tomographic examinations were used to review the changes in the apical lesions and root apex configuration. The patient remained asymptomatic throughout the 30-month follow-up. Periapical radiographic examination revealed no change in the apical lesions of either tooth at 8 months. The periapical radiolucency disappeared on tooth #20 and significantly decreased on tooth #29 by the 30-month follow-up, findings that were also confirmed by cone-beam computed tomographic imaging. No evidence of root lengthening or thickening was observed. Successful revascularization was achieved in a middle-aged patient's teeth. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Adherence evaluation of vented chest seals in a swine skin model.

    Science.gov (United States)

    Arnaud, Françoise; Maudlin-Jeronimo, Eric; Higgins, Adam; Kheirabadi, Bijan; McCarron, Richard; Kennedy, Daniel; Housler, Greggory

    2016-10-01

    Perforation of the chest (open pneumothorax) with and without lung injury can cause air accumulation in the chest, positive intrapleural pressure and lead to tension pneumothorax if untreated. The performance of chest seals to prevent tension physiology depends partially on their ability to adhere to the skin and seal the chest wound. Novel non-occlusive vented chest seals were assessed for their adhesiveness on skin of live swine under normal and extreme environmental conditions to simulate austere battlefield conditions. Chest seals were applied on the back of the swine on skin that was soiled by various environmental contaminants to represent battlefield situations. A peeling (horizontal rim peeling) and detachment and breaching (vertical pulling) techniques were used to quantify the adhesive performance of vented chest seals. Among eight initially selected vented seals, five (Bolin, Russell, Fast breathe, Hyfin and SAM) were further down-selected based on their superior adherence scores at ambient temperatures. The adherence of these seals was then assessed after approximately 17h storage at extreme cold (-19.5°C) and hot (71.5°C) temperatures. Adherence scores for peeling (above 90%) and detachment scores (less than 25%) were comparable for four vented chest seals when tested at ambient temperature, except for the Bolin seal which had higher breaching. Under extreme storage temperatures, adherence peeling scores were comparable to those at ambient temperatures for four chest seals. Scores were significantly lower for the Bolin seal at extreme temperatures. This seal also had the highest detachment and breaching scores. In contrast, the Russell, Fast breathe, Hyfin and SAM seals showed similar ability to stay air tight without breaching after hot storage. No significant difference was found in skin adherence of the five vented chest seals at ambient temperature and the four seals (Russell, Fast breathe, Hyfin and SAM) maintained superior adherence even after

  7. An Integrated Passive (Battery-Free) Seals-and-Tag for International Safeguards

    International Nuclear Information System (INIS)

    Nekoogar, F.; Dowla, F.

    2015-01-01

    The ability to reliably and securely automate the monitoring of SNM is an important goal in Safeguards. Although item level monitoring of SNM requires both seal and tag technologies, the two technologies thus far have been developed more or less independently, and had been a lack of an integrated compact system. An integrated seal-and-tag approach not only aids inspectors to perform their tasks effectively, this approach also allows real-time inspection in large scale facilities. A typical facility could be the size of a large warehouse with hundreds or thousands of items that need to be sealed and monitored in real-time. Previously we reported on advanced secure RF passive (battery-less) tags with special features including, long-range interrogation of passive tags, communicating with passive tags with strong encryption and dynamic authentication features, and the ability to place the tags directly on metal objects. In this paper, we report on a novel secure passive tag integrated with fibre optics seal that allows real-time monitoring of items through secure wireless communications that employs AES encryption and dynamic authentication. Furthermore, the devices can be networked for large scale operations. The proposed passive seal has the same capabilities as active seals in that it allows realtime monitoring. However, the battery lifetimes of conventional active seals are limited or unpredictable. As the long-term storage of SNM might last for several years, these passive seals having been integrated with passive RF tags, extends the lifetime of the physical seals and tags indefinitely, while getting the same performance of active seals and tags. The integrated seal-and-tag is transformational in addressing a critical need in Safeguards area for long-term real-time monitoring. (author)

  8. Tissue Engineering of Necrotic Dental Pulp of Immature Teeth with Apical Periodontitis in Dogs: Radiographic and Histological Evaluation.

    Science.gov (United States)

    El Ashiry, Eman A; Alamoudi, Najlaa M; El Ashiry, Mahmoud K; Bastawy, Hagar A; El Derwi, Douaa A; Atta, Hazem M

    2018-05-15

    To evaluate tissue engineering technology to regenerate pulp-dentin like tissues in pulp canals of immature necrotic permanent teeth with apical periodontitis in dogs. The study was performed on 36 teeth in 12 dogs. The experiment was carried out using split mouth design. In each dog 3 teeth were selected for implementing the study procedure. Apical periodontitis was induced in Group A and B teeth. Group (A): immature upper left 2 nd permanent incisors that were transplanted with a construct of autologous dental pulp stem cells with growth factors seeded in a chitosn hydrogel scaffold. Group (B): immature upper right 2 nd permanent incisor that received only growth factors with scaffold. A third tooth in each dog was selected randomly for isolation of dental pulp stem cells (DPSCs). Both groups were closed with a double coronal seal of white MTA (Mineral trioxide aggregate) and glass ionomer cement. Both groups were monitored radiographically for 4 months and histologically after sacrificing the animals. There was no statistically significant difference in radiographic findings between group (A) and group (B) for healing of radiolucencies, while there was statistically significant difference between group (A) and group (B) regarding radicular thickening, root lengthening and apical closure. Histologically, group (A) teeth showed regeneration of pulp-dentin like tissue while group (B) teeth did not show any tissue regeneration. Dental pulp stem cells and growth factors incorporated in chitosan hydrogel are able to regenerate pulp-dentine like tissue and help in complete root maturation of non-vital immature permanent teeth with apical periodontitis in dogs.

  9. Autologus Platelet Rich Fibrin aided Revascularization of an immature, non-vital permanent tooth with apical periodontitis: A case report.

    Science.gov (United States)

    Jadhav, Ganesh Ranganath; Shah, Dipali; Raghvendra, Srinidhi Surya

    2015-01-01

    Caries or trauma induced non-vital immature permanent tooth with blunderbuss, thin root which are very common among childrens are corrected using regenerative endodontic (revascularization) procedures. In the presented case, a 16-year-old boy reported with chief complaint of pain in maxillary left central incisor (Tooth #21). Tooth #21 showed grade III mobility, draining labial sinus, and short blunderbuss root with diffuse periapical radiolucency. Patient was explained the treatment plan and written informed consent was taken. Platelet rich fibrin (PRF) was prepared according to standard protocol. Autologous PRF was carried to the apical portion of the root canal after inducing revascularization. Access opening was double sealed with MTA and resin modified glass ionomer cement (RMGI). Baseline, 12 month and 18 month follow-up intraoral radiographs were taken. Clinically case was asymptomatic with complete resolution of intraoral sinus. Periapical healing, apical closure, root lengthening and dentinal wall thickening were uneventful. Thus PRF supplementation hastens the predictability and rate of revascularization in non-vital immature permanent teeth.

  10. Pressure Actuated Leaf Seals for Improved Turbine Shaft Sealing

    Science.gov (United States)

    Grondahl, Clayton

    2006-01-01

    This presentation introduces a shaft seal in which leaf seal elements are constructed from slotted shim material formed and layered into a frusto-conical assembly. Limited elastic deflection of seal leaves with increasing system pressure close large startup clearance to a small, non-contacting, steady state running clearance. At shutdown seal elements resiliently retract as differential seal pressure diminishes. Large seal clearance during startup and shutdown provides a mechanism for rub avoidance. Minimum operating clearance improves performance and non-contacting operation promises long seal life. Design features of this seal, sample calculations at differential pressures up to 2400 psid and benefit comparison with brush and labyrinth seals is documented in paper, AIAA 2005 3985, presented at the Advanced Seal Technology session of the Joint Propulsion Conference in Tucson this past July. In this presentation use of bimetallic leaf material will be discussed. Frictional heating of bimetallic leaf seals during a seal rub can relieve the rub condition to some extent with a change in seal shape. Improved leaf seal rub tolerance is expected with bimetallic material.

  11. [Clinical characteristics and speech therapy of lingua-apical articulation disorder].

    Science.gov (United States)

    Zhang, Feng-hua; Jin, Xing-ming; Zhang, Yi-wen; Wu, Hong; Jiang, Fan; Shen, Xiao-ming

    2006-03-01

    To explore the clinical characteristics and speech therapy of 62 children with lingua-apical articulation disorder. Peabody Picture Vocabulary Test (PPVT), Gesell development scales (Gesell), Wechsler Intelligence Scale for Preschool Children (WPPSI) and speech test were performed for 62 children at the ages of 3 to 8 years with lingua-apical articulation disorder. PPVT was used to measure receptive vocabulary skills. GESELL and WPPSI were utilized to represent cognitive and non-verbal ability. The speech test was adopted to assess the speech development. The children received speech therapy and auxiliary oral-motor functional training once or twice a week. Firstly the target sound was identified according to the speech development milestone, then the method of speech localization was used to clarify the correct articulation placement and manner. It was needed to change food character and administer oral-motor functional training for children with oral motor dysfunction. The 62 cases with the apical articulation disorder were classified into four groups. The combined pattern of the articulation disorder was the most common (40 cases, 64.5%), the next was apico-dental disorder (15 cases, 24.2%). The third was palatal disorder (4 cases, 6.5%) and the last one was the linguo-alveolar disorder (3 cases, 4.8%). The substitution errors of velar were the most common (95.2%), the next was omission errors (30.6%) and the last was absence of aspiration (12.9%). Oral motor dysfunction was found in some children with problems such as disordered joint movement of tongue and head, unstable jaw, weak tongue strength and poor coordination of tongue movement. Some children had feeding problems such as preference of eating soft food, keeping food in mouths, eating slowly, and poor chewing. After 5 to 18 times of therapy, the effective rate of speech therapy reached 82.3%. The lingua-apical articulation disorders can be classified into four groups. The combined pattern of the

  12. SEALING ABILITY OF MINERAL TRIOXIDE AGGREGATE, CALCIUM PHOSPHATE CEMENT, AND GLASS IONOMER CEMENT IN THE REPAIR OF FURCATION PERFORATIONS

    Directory of Open Access Journals (Sweden)

    Prabath Singh

    2013-01-01

    Full Text Available Objectives: The purpose of this study was to evaluate the in vitro sealing ability of three repair materials. Mineral trioxide aggregate (MTA; Group A, calcium phosphate cement (CPC; Group B, and light cured glass ionomer cement (GIC; Group C when used to repair the perforation created in the pulpal floor of fifty extracted human permanent molars. Materials and methods: Preparation of access openings and furcation perforations were done, and the teeth divided into five experimental groups (A, B, C including two controls (D, E with ten samples in each group randomly. Following the repair procedure, the pulp chambers and access openings were filled with composite resin and immersed in 2% methylene blue solution for 48 hours. The teeth were sectioned longitudinally and the linear dye penetration measured under a stereo­microscope. Results: The comparison of the linear length of micro-leakage (mm among the experimental groups revealed no significant difference (p = 0.332. On calculating the percentage of depth of leakage to the total length of the perforation, it was observed that the mean leakage was 35.5% in Group A, 53.6% in Group B and the highest, 87.5% in Group C. The mean of leakage percentage was statistically significant by Kruskal-Wallis test (p = 0.003. The results indicated that the dye penetration used as furcation perforation repair material was least with mineral trioxide aggregate. Comparing the depth of penetration of dye, 50% of the Group A samples showed less than 25% of depth penetration. While 40% of Group B cases had more than 50% dye penetration. In our study, all Group C teeth had ≥ 50% dye penetration. Conclusions: The present study indicated that GIC had the greatest dye penetration followed by CPC and MTA. Mineral trioxide aggregate and calcium phosphate cement had comparatively better sealing ability than glass ionomer cement.

  13. Passive Wake Detection Using Seal Whisker-Inspired Sensing

    Science.gov (United States)

    2015-02-01

    companion. The redemption, love, and joy that have come from our time together are written between 6 each line here. Mom, Dad , Jenn, and Robert: thank...specific study is described. 1.1.1 Pinniped Sensory Systems As with many animals, the sensory systems available to the harbor seal are rich and diverse...shifts the mag- netic field (Figure 1-4b). In these test conditions, the seal exhibited poor ability to detect the change. Olfaction There is evidence

  14. VAK III. Seals and sealing system

    International Nuclear Information System (INIS)

    d'Agraives, B.C.; Dal Cero, G.; Debeir, R.; Mascetti, E.; Toornvliet, J.; Volcan, A.

    1986-01-01

    This report presents the VAK III seals and sealing system, which have been used over a period of two years at the Kahl nuclear facility (Federal Republic of Germany), where field tests and feasibility studies were conducted in order to offer a possible solution for the sealing of LWR fuel assemblies. It has been prepared with the aim of an assessment study to be done at the IAEA. It gives all characteristics and technical descriptions for: the sealing principle, the seal construction, the operating tools, the data processing, the drawings, the publications related to that seal. The main points of progress are: the Strong Random Internal Defects (STRID) incorporated in the seals, allowing the obtention of a good signature stability; the Integrity Check on the Seal Status (broken or not) obtained through a decisive mechanical improvement: the Double Breakage Integrity Check (DOBRIC) and with a better ultrasonic evidence of that status; the provision of new function tools, allowing the performance of Identity Measurements in dry conditions (which means also at the manufacturer plant) or in deeper water (wet storage); the study and development of a new JRC VAK 45 Compact Instrument Box, in which all the measuring functions can be grouped and incorporating an autonomous Minicomputer offering to the Inspection the possibility of performing, on the spot, Correlation and Decision processes. The general benefit of such a feasibility study should be to convince the potential users that such a Safeguards Sealing System can be studied for slightly - or largely - different other applications, provided that the Basic and Operating Functions required to the system be clearly defined, possibly after a common agreement would be stated

  15. Experimental study on a magnetofluid sealing liquid for propeller shaft

    Science.gov (United States)

    Zhao, Chang-Fa; Sun, Rong-Hua; Zheng, Jin-Xing

    2003-06-01

    The selecting and preparing method of the basic material of magnetic fluid was introduced. By using a chemical method, the magnetic micropowder Fe3O4 was successfully yielded, and an oil-base as a working carrier and dispersing agent was determined. The preparation process of the magnetic fluid and prescription of the oil-base magnetic fluid were discussed. The simulation experimental rig of magnetic fluid sealing for propeller shaft was designed. The sealing ability experiment was conducted and results were analyzed. The pressure of sealing is up to 2 MPa.

  16. Testing of elastomer seals using small-size rigs

    International Nuclear Information System (INIS)

    Leeks, C.W.E.; Dunford, B.; Barnfield, J.H.; Gray, I.L.S.

    1997-01-01

    This paper looks at the use of small size seal leakage test rigs to demonstrate the compliance of full size container seals against the IAEA Transport Regulation's limits for activity release for normal transport and accident conditions. The detailed requirements of the regulations are discussed and it is concluded that an appropriate test programme to meet these requirements using only small size test rigs, can normally be set up and carried out on a relatively short time scale. It is important that any small test rigs should be designed to represent the relevant features of the seal arrangement and the overall test programme should cover all of the conditions, specified by the regulations, for the type, classification and contents of the container under consideration. The parameters of elastomer O-rings, which affect their sealing ability, are considered and those which are amenable to small scale testing or have to be modelled at full size are identified. Generally, the seals used in leakage tests have to be modelled with a full size cross-section but can have a reduced peripheral length. (Author)

  17. Cover-gas seals: 11-LMFBR seal-test program

    International Nuclear Information System (INIS)

    Steele, O.P. III; Horton, P.H.

    1977-01-01

    The objective of the Cover Gas Seal Material Development Program is to perform the engineering development required to provide reliable seals for LMFBR application. Specific objectives are to verify the performance of commercial solid cross-section and inflatable seals under reactor environments including radiation, to develop advanced materials and configurations capable of achieving significant improvement in radioactive gas containment and seal temperature capabilities, and to optimize seal geometry for maximum reliability and minimal gas permeation

  18. Effect of the angle of apical resection on apical leakage, measured with a computerized fluid filtration device.

    Science.gov (United States)

    Garip, Hasan; Garip, Yıldız; Oruçoğlu, Hasan; Hatipoğlu, Seda

    2011-03-01

    We determined the effect of the angle of apical resection on apical leakage using a computerized fluid filtration meter with a laser system and a digital air pressure regulator in 46 extracted single-rooted human teeth. Orthograde endodontic treatment was performed. The root canals were prepared up to a size 50 K-type file with 17% EDTA solution (Roth International, Chicago, IL) and 5% NaOCl solution as the irrigant. Gates Glidden burs (Maillefer Instruments, Ballaigues, Switzerland) were used to flare the coronal two thirds of the canal. All canals were dried with paper points and then obturated using cold lateral condensation (except for the positive controls) of gutta-percha points and AH plus (Dentsply DeTrey, Konstanz, Germany). All 40 roots were sectioned 3 mm from the apex. Forty teeth were assigned randomly into 1 of 4 experimental groups of 10 teeth each: in group 1, the teeth were resected apically (90° angle) and the cavities were obturated with mineral trioxide aggregate (MTA); in group 2, after apical resection (90° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA; in group 3, the teeth were resected apically (∼45° angle) and the cavities were obturated with MTA; and in group 4, after apical resection (∼45° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA. An additional 6 teeth were used as controls (3 each, negative and positive controls). Apical leakage was measured using a computerized fluid filtration meter with a laser system. The mean apical microleakage was 2.0 ± 0.4 × 10(-4), 1.6 ± 0.6 × 10(-4), 1.6 ± 0.9 × 10(-4), and 1.8 ± 0.7 × 10(-4) μL/cmH(2)O/min(-1) at 1.2 atm, in groups 1 to 4, respectively. Although the mean apical microleakage was greater in group 1, the differences among the 4 groups were not statistically significant (P > .05). The results of these in vitro studies showed that when an

  19. Apical root resorption in orthodontically treated adults.

    Science.gov (United States)

    Baumrind, S; Korn, E L; Boyd, R L

    1996-09-01

    This study analyzed the relationship in orthodontically treated adults between upper central incisor displacement measured on lateral cephalograms and apical root resorption measured on anterior periapical x-ray films. A multiple linear regression examined incisor displacements in four directions (retraction, advancement, intrusion, and extrusion) as independent variables, attempting to account for observed differences in the dependent variable, resorption. Mean apical resorption was 1.36 mm (sd +/- 1.46, n = 73). Mean horizontal displacement of the apex was -0.83 mm (sd +/- 1.74, n = 67); mean vertical displacement was 0.19 mm (sd +/- 1.48, n = 67). The regression coefficients for the intercept and for retraction were highly significant; those for extrusion, intrusion, and advancement were not. At the 95% confidence level, an average of 0.99 mm (se = +/- 0.34) of resorption was implied in the absence of root displacement and an average of 0.49 mm (se = +/- 0.14) of resorption was implied per millimeter of retraction. R2 for all four directional displacement variables (DDVs) taken together was only 0.20, which implied that only a relatively small portion of the observed apical resorption could be accounted for by tooth displacement alone. In a secondary set of univariate analyses, the associations between apical resorption and each of 14 additional treatment-related variables were examined. Only Gender, Elapsed Time, and Total Apical Displacement displayed statistically significant associations with apical resorption. Additional multiple regressions were then performed in which the data for each of these three statistically significant variables were considered separately, with the data for the four directional displacement variables. The addition of information on Elapsed Time or Total Apical Displacement did not explain a significant additional portion of the variability in apical resorption. On the other hand, the addition of information on Gender to the

  20. Effect of apical clearing technique on the treatment outcome of teeth with asymptomatic apical periodontitis: A randomized clinical trial.

    Science.gov (United States)

    Mittal, Priya; Logani, Ajay; Shah, Naseem; Pandey, R M

    2016-01-01

    This study aims to compare the periapical healing of teeth with asymptomatic apical periodontitis treated either by conventional apical preparation (CAP) or apical clearing technique (ACT). Twenty subjects with bilateral nonvital similar teeth exhibiting comparable periapical index (PAI) score were enrolled and randomly allocated. Group I (CAP, n = 20): Apical preparation three sizes greater (master apical file [MAF]) than the first binding file at the established working length. Group II (ACT, n = 20): Apical preparation three sizes greater than the MAF that was followed by dry reaming. Root canal therapy was accomplished in single-visit for all the teeth. They were pursued radiographically at 3, 6, 9 and 12 months. Pre- and post-treatment PAI scores were compared. To ascertain the proportion of healed teeth between the two groups, McNemar Chi-square test was applied. At 3, 6, and 9 months' time interval the proportion of healed teeth for Group II (ACT) was greater in comparison to Group I (CAP) (P < 0.05). However, at 12 months follow-up period this difference was not significant (P = 0.08). ACT enhanced the healing kinetics. However, the long-term (12 months) radiographic outcome was similar for either technique.

  1. Quantitative assessment of apical debris extrusion and intracanal debris in the apical third, using hand instrumentation and three rotary instrumentation systems.

    Science.gov (United States)

    H K, Sowmya; T S, Subhash; Goel, Beena Rani; T N, Nandini; Bhandi, Shilpa H

    2014-02-01

    Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third.

  2. Proliferation of epithelial cell rests, formation of apical cysts, and regression of apical cysts after periapical wound healing.

    Science.gov (United States)

    Lin, Louis M; Huang, George T-J; Rosenberg, Paul A

    2007-08-01

    There is continuing controversy regarding the potential for inflammatory apical cysts to heal after nonsurgical endodontic therapy. Molecular cell biology may provide answers to a series of related questions. How are the epithelial cell rests of Malassez stimulated to proliferate? How are the apical cysts formed? How does the lining epithelium of apical cysts regress after endodontic therapy? Epithelial cell rests are induced to divide and proliferate by inflammatory mediators, proinflammatory cytokines, and growth factors released from host cells during periradicular inflammation. Quiescent epithelial cell rests can behave like restricted-potential stem cells if stimulated to proliferate. Formation of apical cysts is most likely caused by the merging of proliferating epithelial strands from all directions to form a three-dimensional ball mass. After endodontic therapy, epithelial cells in epithelial strands of periapical granulomas and the lining epithelium of apical cysts may stop proliferating because of a reduction in inflammatory mediators, proinflammatory cytokines, and growth factors. Epithelial cells will also regress because of activation of apoptosis or programmed cell death through deprivation of survival factors or by receiving death signals during periapical wound healing.

  3. Mechanical seals

    CERN Document Server

    Mayer, E

    1977-01-01

    Mechanical Seals, Third Edition is a source of practical information on the design and use of mechanical seals. Topics range from design fundamentals and test rigs to leakage, wear, friction and power, reliability, and special designs. This text is comprised of nine chapters; the first of which gives a general overview of seals, including various types of seals and their applications. Attention then turns to the fundamentals of seal design, with emphasis on six requirements that must be considered: sealing effectiveness, length of life, reliability, power consumption, space requirements, and c

  4. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  5. Sealing Failure Analysis on V-Shaped Sealing Rings of an Inserted Sealing Tool Used for Multistage Fracturing Processes

    Directory of Open Access Journals (Sweden)

    Gang Hu

    2018-06-01

    Full Text Available The inserted sealing tool is a critical downhole implement that is used to balance the downhole pressure in multistage fracturing operations and prevent fracturing fluid from overflow and/or backward flow. The sealing ring of an inserted sealing tool plays an important role in downhole sealing since a sealing failure would ail the fracturing operation. In order to improve the sealing performance and reduce the potential fracturing failures, this research aims to investigate the influence of V-shaped sealing ring geometries on sealing performance. Constitutive experiments of rubber materials were carried out and the parameters of the constitutive relationship of rubber materials were obtained. A two-dimensional axisymmetric model considering the sealing ring has been established and influences are investigated with considerations of various system parameters and operating conditions. It is found that the stresses concentrated at the shoulder and inner vertex of the sealing ring have direct impact on the damage of the sealing rings under operational conditions. Moreover, the sealing interference, among several other factors, greatly affects the life of the sealing ring. A new design of the sealing ring is suggested with optimized geometric parameters. Its geometric parameters are the edge height of 5 mm, the vertex angle of 90°–100°, and the interference of 0.1 mm, which show a better performance and prolonged operation life of the sealing ring.

  6. The antimicrobial effect of apical box versus apical cone preparation using iodine potassium iodide as root canal dressing

    DEFF Research Database (Denmark)

    Markvart, Merete; Dahlén, Gunnar; Reit, Claes-Erik

    2013-01-01

    Abstract Purpose. The purpose was to study the reduction of intra-canal microflora in premolars with apical periodontitis instrumented with either apical box or apical cone preparation and to provide measurements of intervention effects to allow proper power calculation in future clinical trials.......-week post-sampling, a power calculation revealed that over 900 patients are needed to show a difference of 9% between the two protocols tested. Conclusions. Future trials should be conducted using stringent protocols and as multi-centre trials for reaching the required information size....

  7. The effect of gingival wall location on the marginal seal of class ii restorations prepared with a flowable bulk-fill resin-based composite.

    Science.gov (United States)

    Segal, P; Candotto, V; Ben-Amar, A; Eger, M; Matalon, S; Lauritano, D; Ormianer, Z

    2018-01-01

    SureFil SDR is a flowable resin-based composite that allows a single incremental bulk placement. The marginal seal of SureFil SDR at the gingival margins of class II restorations located apical to the cemento-enamel-junction (CEJ) has not been adequately evaluated compared to those located occlusal to the CEJ. Forty class II cavities were prepared in human molars. The gingival margins of 20 preparations were located 0.5 mm occlusal to the CEJ, and the other 20 preparations were located 0.5 mm apical to the CEJ. The cavities surfaces were bonded with XenoV dental adhesive and filled with SDR in one bulk increment up to 4 mm, after which they were covered with CeramX. The teeth were subjected to thermo-and load-cycling, and their gingival margins were exposed to 0.5% basic-fuchsin solution. The specimens were sectioned mesio-distally and scored for microleakage. A Wilcoxon test for pairwise comparison was performed to determine significance. Dye penetration was observed in 30% of the 20 restorations with cavo-surface margins located occlusal to the CEJ and in 55% of the 20 restorations with cavo-surface margins located apical to the CEJ. The bulk-fill flowable resin base SureFil SDR with XenoV dental adhesive provided a better marginal seal in class II restorations with gingival margins above the CEJ compared to restorations with gingival margins below the CEJ. SDR should not be recommended for class II cavity preparations with gingival margins located below the CEJ.

  8. The apical leakage of mineral trioxide aggregate as the retrograde filling material with various mixing agents

    Directory of Open Access Journals (Sweden)

    Ema Mulyawati

    2010-06-01

    Full Text Available Background: Mineral trioxide aggregate (MTA is relatively considered as a new material in endodontic. It even has been used as retrograde filling material due to its biocompatibility, antibacterial effect, sealing ability and anti-moist effect. Some materials have been used as mixing agent to achieve an appropiate setting of MTA. Purpose: The aim of this study is to investigate the effect of the mixing agents of MTA towards the apical leakage when they are used together as retrograde filling materials. Method: The samples of this research consist of 30 human extracted upper central incisors. First, the crown of each tooth is sectioned. The root canals are prepared by using the conventional technique and then are obturated with gutta percha. After cutting the root apex, 2 mm from apical, class 1 cavities are prepared by using fissure bur with the depth of 3 mm. The samples then are divided into 3 groups with 10 teeth for each. Group I uses aquabidest as mixing agent of MTA (MTA-aquabidest, group II uses saline (MTA-saline, while group III uses 0.12% chlorhexidine (MTA-chlorhexidine. The apex of each group then is filled with the mixing MTA determined already. Afterwards, clearing method is used to evaluate the apical leakage. The apical leakage actually is determined by measuring the depth of methylene blue penetration with stereomicroscope. The statictical analyses of the linear dye penetration then are performed with analysis of varians ANOVA. Result: The dye penetration for both MTA-aquadest and MTA-saline groups indicates the lowest penetration, and there is even a significant difference compared with MTA-0.12% chlorhexidine group (p<0.005. Conclusion: It can be concluded that aquabidest and saline as mixing agents of MTA produce less apical leakage compared with 0.12% chlorhexidine.Latar belakang: Mineral trioxide aggregate (MTA merupakan bahan yang relatif baru dalam bidang endodontik. Bahan tersebut diindikasikan sebagai bahan pengisi

  9. The effect of thermocycling on the sealing ability of White Mineral Trioxide Aggregate: an in vitro study

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Saghiri

    2016-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the effect of thermocycling on the sealing ability of White Mineral Trioxide Aggregate (WMTA after application for management of furcation perforation. MATERIALS AND METHOD: Thirty two human permanent mandibular molar teeth were chosen and after root amputation, the coronal parts were further trimmed and conventional access cavities were prepared. Furcation perforations were made with diamond bur and Peeso drills. Samples were divided into 3 experimental groups (n=10 and two control groups (n=1. The perforations were filled with WMTA in the experimental groups; in the control groups samples remained unfilled. Samples in the first group remained without further treatment, while in the second and third groups, teeth were thermocycled 500 and 800 times between 5 to 55 °C prior to leakage testing. Microleakage testing was done by using bovine serum albumin for 90 days. The number of days for color change was used as an indicator of protein leakage. Data were analyzed by using one-way analysis of variance and a post hoc Tukey test at a significance level of p<0.05. RESULTS: Non-thermocycled teeth showed significantly the longest time necessary for protein leakage to occur in comparison with the other two thermocycled groups (p<0.0001. The samples after 800 cycles showed the lowest resistance to protein leakage, while samples after 500 cycles indicated significantly more resistance against leakage (p<0.0001. CONCLUSION: Thermocycling can remarkably influence the microleakage property of WMTA. Thermal changes occurring inside the oral cavity might jeopardize the sealing property of the applied cement, which can lead to microleakage and possible failure of treatment in a clinical scenario.

  10. Cover gas seals: FFTF-LMFBR seal test program

    International Nuclear Information System (INIS)

    Kurzeka, W.; Oliva, R.; Welch, T.S.; Shimazaki, T.

    1974-01-01

    The objectives of this program are to: (1) conduct static and dynamic tests to demonstrate or determine the mechanical performance of full-size (cross section) FFTF fuel transfer machine and reactor vessel head seals intended for use in a sodium vapor-inert gas environment, (2) demonstrate that these FFTF seals or new seal configurations provide acceptable fission product and cover gas retention capabilities at Clinch River Breeder Reactor Plant (CRBRP) operating environmental conditions other than radiation, and (3) develop improved seals and seal technology for the CRBRP to support the national objective to reduce all atmospheric contaminations to low levels

  11. Five-year longitudinal assessment of the prognosis of apical microsurgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Jensen, Simon S; Hänni, Stefan

    2012-01-01

    Apical surgery is an important treatment option for teeth with post-treatment apical periodontitis. Knowledge of the long-term prognosis is necessary when weighing apical surgery against alternative treatments. This study assessed the 5-year outcome of apical surgery and its predictors in a cohor...

  12. Definitions of apical vaginal support loss: a systematic review.

    Science.gov (United States)

    Meister, Melanie R L; Sutcliffe, Siobhan; Lowder, Jerry L

    2017-03-01

    We sought to identify and summarize definitions of apical support loss utilized for inclusion, success, and failure in surgical trials for treatment of apical vaginal prolapse. Pelvic organ prolapse is a common condition affecting more than 3 million women in the US, and the prevalence is increasing. Prolapse may occur in the anterior compartment, posterior compartment or at the apex. Apical support is considered paramount to overall female pelvic organ support, yet apical support loss is often underrecognized and there are no guidelines for when an apical support procedure should be performed or incorporated into a procedure designed to address prolapse. A systematic literature search was performed in 8 search engines: PubMed 1946-, Embase 1947-, Cochrane Database of Systematic Reviews, Cochrane Database of Abstracts of Review Effects, Cochrane Central Register of Controlled Trials, ClinicalTrials.gov, Proquest Dissertations and Theses, and FirstSearch Proceedings, using key words for apical pelvic organ prolapse and apical suspension procedures through April 2016. Searches were limited to human beings using human filters and articles published in English. Study authors (M.R.L.M., J.L.L.) independently reviewed publications for inclusion based on predefined variables. Articles were eligible for inclusion if they satisfied any of the following criteria: (1) apical support loss was an inclusion criterion in the original study, (2) apical support loss was a surgical indication, or (3) an apical support procedure was performed as part of the primary surgery. A total of 4469 publications were identified. After review, 35 articles were included in the analysis. Prolapse-related inclusion criteria were: (1) apical prolapse (n = 20, 57.1%); (2) overall prolapse (n = 8, 22.8%); or (3) both (n = 6, 17.1%). Definitions of apical prolapse (relative to the hymen) included: (1) apical prolapse >-1 cm (n = 13, 50.0%); (2) apical prolapse >+1 cm (n = 7, 26.9%); (3) apical

  13. Effectiveness of EDTA as the irrigation solution to remove smear layer in root canal

    Directory of Open Access Journals (Sweden)

    Kurniasri Amas Achiar

    2009-07-01

    Full Text Available One of the objectives of successful endodontic treatment is the hermetic obturation of the root canal system. To achieve this, the root canal filling must seal the canal space both apically and coronally to prevent the ingress of microorganisms or tissue fluids into the canal space. Apical leakage is reported a common reason for the clinical failure of endodontic therapy. Leakage through an obturated root canal is expected to take place at interfaces between sealer and dentin or sealer and gutta-percha, or through voids within the sealer. Hence, the sealing quality of root canal filling depends much on the sealing ability of the sealer. Therefore, anything that may influence the adaptation of the root filling to the canal wall is can determine the degree and the extent of leakage, and ultimately the prognosis of the endodontic therapy. In endodontic therapy, the smear layer formation results from root canal preparation and may influence the effective seal of the root canal system. The smear layer formation is mainly composed of inorganic components (dentin debris and organic materials, such as pulp tissue remnant, bacteria, and blood cells. Removal of the smear layer from the root canal walls before the obturation can reduce the leakage of root canal sealer. To remove the smear layer use 10 ml 17% EDTA followed by 10 ml of 5.25% NaOCl as irrigating solution. This paper discribe about how the effectivity of EDTA as irigating solution to remove the smear layer especially in the apical root canal with many lateral canal to reduce the apical leakage.

  14. Revascularization and Apical Plug in an Immature Molar

    Science.gov (United States)

    Roghanizadeh, Leyla; Fazlyab, Mahta

    2018-01-01

    Managing of necrotic permanent teeth with immature apices is a treatment challenges. Treatment of such teeth includes apexification, apical plug and more recently, revascularization technique with the probable advantage of continuation of root development. In the present case report the referred patient had discomfort with a necrotic immature mandibular first molar. Periapical radiography showed a rather large apical lesion around immature roots. Revascularization protocol using calcium-enriched mixture (CEM) cement was indicated for the mesial root. However, in distal canal apical plug technique was applied. At 2-year follow-up, both procedures were successful in relieving patient’s symptoms. Dentin formation and increase in length of the mesial root was obvious. Apical plug and revascularization technique proved to be successful in management of necrotic immature teeth; moreover, revascularization carried the advantage of continuation of root development. PMID:29692851

  15. The design and performance of seals for controlling radionuclide migration along boreholes, shafts and adits

    International Nuclear Information System (INIS)

    Broyd, T.W.

    1993-01-01

    Requirements for sealing an underground radioactive waste disposal facility are assessed, based on proposals for a deep repository in hard rock. Information is reviewed on the properties and performance characteristics of seals, of a range of materials, design and emplacement techniques, and for different industry end-uses. The ability to predict long-term seal performance is also addressed. Critical aspects of seal design and characteristics are proposed and recommendations are made for their performance testing. (author)

  16. Failure analysis and seal life prediction for contacting mechanical seals

    Science.gov (United States)

    Sun, J. J.; He, X. Y.; Wei, L.; Feng, X.

    2008-11-01

    Fault tree analysis method was applied to quantitatively investigate the causes of the leakage failure of mechanical seals. It is pointed out that the change of the surface topography is the main reasons causing the leakage of mechanical seals under the condition of constant preloads. Based on the fractal geometry theory, the relationship between the surface topography and working time were investigated by experiments, and the effects of unit load acting on seal face on leakage path in a mechanical seal were analyzed. The model of predicting seal life of mechanical seals was established on the basis of the relationship between the surface topography and working time and allowable leakage. The seal life of 108 mechanical seal operating at the system of diesel fuel storage and transportation was predicted and the problem of the condition monitoring for the long-period operation of mechanical seal was discussed by this method. The research results indicate that the method of predicting seal life of mechanical seals is feasible, and also is foundation to make scheduled maintenance time and to achieve safe-reliability and low-cost operation for industrial devices.

  17. Improved operation in CANDU plants with CAN8 PHT pump seals

    International Nuclear Information System (INIS)

    Graham, T.; McInnes, D.; Rhodes, D.

    1997-01-01

    The CAN8 PHT pump seal is currently operating in twenty-one pumps, twelve at Bruce A, seven at Bruce B and in both pumps at Grand Gulf Nuclear Station (GGNS). The CAN8 seal has markedly improved performance over the CAN2 seal previously used at the Bruce stations and the SU seals previously used at GGNS. Details of the performance improvements are discussed. Prior to installation in Bruce B, the CAN8 seal was slightly modified and then demonstrated to be resistant to reverse pressurization failures, since this was a known failure mechanism with the CAN2 seal. Subsequent experience showed that Bruce A was also susceptible to reverse pressure incidents. A review of plant operating procedures at Bruce A showed reverse pressure was likely the initiating factor for several previously unexplained seal disturbances. The reverse pressure failure mechanism is described, as are the improved system operating procedures designed to prevent it. Preventative procedures have now been implemented across Ontario Hydro Nuclear. The ability to track down seal failure mechanisms such as this is greatly enhanced by the improved system monitoring and data retrieval now in place at Bruce A and Bruce B. (author)

  18. Ceramic Seal.

    Energy Technology Data Exchange (ETDEWEB)

    Smartt, Heidi A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Romero, Juan A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Custer, Joyce Olsen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hymel, Ross W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Krementz, Dan [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Gobin, Derek [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Harpring, Larry [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Martinez-Rodriguez, Michael [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Varble, Don [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); DiMaio, Jeff [Tetramer Technologies, Pendleton, SC (United States); Hudson, Stephen [Tetramer Technologies, Pendleton, SC (United States)

    2016-11-01

    Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.

  19. Ceramic Seal

    International Nuclear Information System (INIS)

    Smartt, Heidi A.; Romero, Juan A.; Custer, Joyce Olsen; Hymel, Ross W.; Krementz, Dan; Gobin, Derek; Harpring, Larry; Martinez-Rodriguez, Michael; Varble, Don; DiMaio, Jeff; Hudson, Stephen

    2016-01-01

    Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.

  20. Predicting placebo response in adolescents with major depressive disorder: The Adolescent Placebo Impact Composite Score (APICS).

    Science.gov (United States)

    Nakonezny, Paul A; Mayes, Taryn L; Byerly, Matthew J; Emslie, Graham J

    2015-09-01

    The aim of this study was to construct a composite scoring system to predict the probability of placebo response in adolescents with Major Depressive Disorder (MDD). Participants of the current study were 151 adolescents (aged 12-17 years) who were randomized to the placebo arm (placebo transdermal patches) of a randomized controlled trial (RCT) comparing the selegiline transdermal patch with placebo (DelBello et al., 2014). The primary outcome of response was defined as a CGI-I score of 1 or 2 (very much or much improved) at week 12 (study-end) or exit. As a first step, a multiple logistic mixed model was used to estimate the odds of placebo response from each predictor in the model, including age, CDRS-R total at baseline (depressive symptom severity), history of recurrent depression (yes vs. no), sex (female vs. male), and race (non-Caucasian vs. Caucasian). On the basis of the initial logistic mixed model analysis, we then constructed an Adolescent Placebo Impact Composite Score (APICS) that became the sole predictor in a re-specified Bayesian logistic regression model to estimate the probability of placebo response. Finally, the AUC for the APICS was tested against a nominal area of 0.50 to evaluate how well the APICS discriminated placebo response status. Among the 151 adolescents, with a mean age of 14.6 years (SD = 1.6) and a mean baseline CDRS-R total of 60.6 (SD = 12.1), 68.2% were females, 50.3% was Caucasian, and 39.7% had a history of recurrent depression. Placebo response rate was 58.3%. Based on the logistic mixed model, the re-specified equation with the highest discriminatory ability to estimate the probability of placebo response was APICS = age + (0.32 × CDRS-R Total at baseline) + (-2.85 × if female) + (-5.50 × if history of recurrent depression) + (-5.85 × if non-Caucasian). The AUC for this model was 0.59 (p = .049). Within a Bayesian decision-theoretic framework, in 95.5% of the time, the 10,000 posterior Monte Carlo samples suggested

  1. Revascularization and periapical repair after endodontic treatment using apical negative pressure irrigation versus conventional irrigation plus triantibiotic intracanal dressing in dogs' teeth with apical periodontitis.

    Science.gov (United States)

    da Silva, Lea Assed Bezerra; Nelson-Filho, Paulo; da Silva, Raquel Assed Bezerra; Flores, Daniel Silva Herzog; Heilborn, Carlos; Johnson, James D; Cohenca, Nestor

    2010-05-01

    The objective of this study was to evaluate in vivo the revascularization and the apical and periapical repair after endodontic treatment using 2 techniques for root canal disinfection (apical negative pressure irrigation versus apical positive pressure irrigation plus triantibiotic intracanal dressing) in immature dogs' teeth with apical periodontitis. Two test groups of canals with experimentally induced apical periodontitis were evaluated according to the disinfection technique: Group 1, apical negative pressure irrigation (EndoVac system), and Group 2, apical positive pressure irrigation (conventional irrigation) plus triantibiotic intracanal dressing. In Group 3 (positive control), periapical lesions were induced, but no endodontic treatment was done. Group 4 (negative control) was composed of sound teeth. The animals were killed after 90 days and the maxillas and mandibles were subjected to histological processing. The sections were stained with hematoxylin and eosin and Mallory Trichrome and examined under light microscopy. A description of the apical and periapical features was done and scores were attributed to the following histopathological parameters: newly formed mineralized apical tissue, periapical inflammatory infiltrate, apical periodontal ligament thickness, dentin resorption, and bone tissue resorption. Intergroup comparisons were done by the Kruskal-Wallis and Dunn's tests (alpha = 0.05). Although statistically significant difference was found only for the inflammatory infiltrate (P irrigation with the EndoVac system can be considered as a promising disinfection protocol in immature teeth with apical periodontitis, suggesting that the use of intracanal antibiotics might not be necessary. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  2. Mechanical seal assembly

    Science.gov (United States)

    Kotlyar, Oleg M.

    2001-01-01

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transferring it to the mechanical diode.

  3. Mechanical Seal Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Kotlyar, Oleg M.

    1999-06-18

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transferring it to the mechanical diode.

  4. Regeneration of okra ( Abelmoschus esculentus L.) via apical shoot ...

    African Journals Online (AJOL)

    Abelmoschus esculentus L. Monech) via apical shoot culture system. The study of apical shoot culture system was found effective for regeneration of apical shoots. The okra (A. esculentus L. Monech) N-550 line evolved at R&D, Nirmal Seeds Pvt. Ltd., ...

  5. Glass sealing

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K.; Kovacic, L.; Chambers, R.S. [Sandia National Labs., Albuquerque, NM (United States)

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  6. IN VIVO ANALYSIS OF SOME KEY CHARACTERISTICS OF THE APICAL ZONE IN TEETH WITH CHRONIC APICAL PERIODONTITIS.

    Directory of Open Access Journals (Sweden)

    Angela Gusiyska

    2014-11-01

    Full Text Available Introduction: The pathogenesis of internal and external resorptive processes in the dental tissues and those of the periapical zone is not fully understood, but the main purpose, either in teeth with internal resorption or in teeth with periapical lesions, is decontamination of the endodontic space and subsequent three-dimensional obturation in order to isolate periapical and oral tissues and prevent reinfection. Purpose: The aim of this article is to analyze in vivo some key characteristics of the apical zone in teeth with chronic apical periodontitis. Material and Methods: To facilitate the clinical protocol after the radiographic analysis and assessment of patency, the working lengths of 153 root canals (n = 153 in 106 teeth were determined. The clinical widths of the apical narrowing were measured by using the last instrument (ISO 0.02 tapered file, which can move freely through the apical narrowing after electrometric determination of the working length (Raypex 5 /VDW, Germany/. Results and Discussion: Determination of working width and working length is important for realizing the first stage of decontamination – maximum instrumentation of the endodontic space and choice of a clinical protocol. The classification of root canals in a particular group according to the relative patency or lysed apical opening is important for the selection of obturation technique, which is essential for reducing the microleakage in the zone. Conclusion: Since the target of this work were teeth with CAP, in the majority of the cases with clinical findings of root canals with preexisting filling, radicular pins, obliteration, separated canal instruments, perforations at different levels, via falsa or thresholds, the access to the apical zone was not subjected to a closely observed instrumental clinical protocol. In the treatment of each case, however, the clinical principles of modern endodontic treatment were closely observed.

  7. Amphibious hearing in ringed seals (Pusa hispida): underwater audiograms, aerial audiograms and critical ratio measurements.

    Science.gov (United States)

    Sills, Jillian M; Southall, Brandon L; Reichmuth, Colleen

    2015-07-01

    Ringed seals (Pusa hispida) are semi-aquatic marine mammals with a circumpolar Arctic distribution. In this study, we investigate the amphibious hearing capabilities of ringed seals to provide auditory profiles for this species across the full range of hearing. Using psychophysical methods with two trained ringed seals, detection thresholds for narrowband signals were measured under quiet, carefully controlled environmental conditions to generate aerial and underwater audiograms. Masked underwater thresholds were measured in the presence of octave-band noise to determine critical ratios. Results indicate that ringed seals possess hearing abilities comparable to those of spotted seals (Phoca largha) and harbor seals (Phoca vitulina), and considerably better than previously reported for ringed and harp seals. Best sensitivity was 49 dB re. 1 µPa (12.8 kHz) in water, and -12 dB re. 20 µPa (4.5 kHz) in air, rivaling the acute hearing abilities of some fully aquatic and terrestrial species in their respective media. Critical ratio measurements ranged from 14 dB at 0.1 kHz to 31 dB at 25.6 kHz, suggesting that ringed seals--like other true seals--can efficiently extract signals from background noise across a broad range of frequencies. The work described herein extends similar research on amphibious hearing in spotted seals recently published by the authors. These parallel studies enhance our knowledge of the auditory capabilities of ice-living seals, and inform effective management strategies for these and related species in a rapidly changing Arctic environment. © 2015. Published by The Company of Biologists Ltd.

  8. Rotary plug seal

    International Nuclear Information System (INIS)

    Ito, Koji; Abiko, Yoshihiro.

    1981-01-01

    Purpose: To enable fuel exchange even upon failure of regular seals and also to enable safety seal exchange by the detection of the reduction in the contact pressure of a rotary plug seal. Constitution: If one of a pair of regular tube seals for the rotary plug is failed during ordinary operation of a FBR type reactor, the reduction in the contact pressure of the seal to the plug gibbousness is detected by a pressure gauge and a solenoid valve is thereby closed. Thus, a back-up-tube seal provided above or below the tube seal is press-contacted by way of argon gas to the gibbousness to enter into operation state and lubricants are supplied from an oil tank. In such a structure, the back-up-tube seal is operated before the failure of the tube seal to enable to continue the fuel exchange work, as well as safety exchange for the tube seal. (Moriyama, K.)

  9. A novel conservative approach combining “SealBio” and “Surgical Fenestration” for healing of large periapical cystic lesions of endodontic origin: A pilot study

    Directory of Open Access Journals (Sweden)

    Naseem Shah

    2017-01-01

    Full Text Available Objectives: To evaluate the treatment outcome of large periapical cystic lesions treated by combining two novel, conservative approaches, “SealBio” and “Surgical Fenestration”. Materials and Methods: Five cases (4M:1F, age range 14-38 years, mean age 24.5 years of large periapical cystic lesions, diagnosed on clinical and radiographic examination, were included in the study. After informed consent, endodontic treatment was initiated; chemo-mechanical preparation and intra-canal dressing of calcium hydroxide was given. At the next sitting after one week, further disinfection root canals was done by “apical clearing”, “apical foramen widening” and irrigation. A cotton pellet was kept in the access cavity. After local anaesthesia, full thickness muco-periosteal flap was reflected and the thinned out bone was removed with bone rongers, a small piece of cystic lining was excised and the cystic cavity was copiously flushed with Betadine solution. The remaining cystic lining was gently curetted and the flap was sutured back. “SealBio” was performed after gentle irrigation with saline and intentional over instrumentation. A calcium sulphate based cement was pushed in the cervical third of the canal and the access opening was sealed with glass ionomer cement. Patient was prescribed antibiotics and anti-inflammatory drugs for 5 days and sutures were removed after 7 days. Patients were followed up clinically and radiographically at regular intervals. Conclusions: In this pilot study, treatment outcome after combined technique of “SealBio” and “Surgical fenestration” was found to be highly effective in healing of large periapical cystic lesions. It was simple to perform and very conservative treatment; it required minimal bone removal, obviated the need for complete cyst enucleation, apicectomy and retrograde filling.

  10. Apical pulmonary abscesses

    International Nuclear Information System (INIS)

    Mercado Ferrer, Cesar A; Serrano Vasquez, Francisco O

    2004-01-01

    We presented the case of a 54 year-old man with bilateral apical pulmonary abscess who consults due to fever and bronchorrhoea, isolating moraxella catharralis that is managed with ampicillin-sulbactam with an adequate clinical and radiological evolution

  11. Sealing performance of a magnetic fluid seal for rotary blood pumps.

    Science.gov (United States)

    Mitamura, Yoshinori; Takahashi, Sayaka; Kano, Kentaro; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya; Higuchi, Taka-Aki

    2009-09-01

    A magnetic fluid (MF) for a rotary blood pump seal enables mechanical contact-free rotation of the shaft and, hence, has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a "shield" mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Under the condition of continuous flow, the MF seal remained in perfect condition against a pressure of 298 mm Hg (pump flow rate: 3.96 L/min). The seal was also perfect against a pressure of 170 mm Hg in a continuous flow of 3.9 L/min for 275 days. We have developed a MF seal that works in liquid against clinically used pressures. The MF seal is promising as a shaft seal for rotary blood pumps.

  12. Association of human herpesvirus 6 subtypes with symptomatic apical periodontitis.

    Science.gov (United States)

    Hernádi, Katinka; Csoma, Eszter; Adám, Balázs; Szalmás, Anita; Gyöngyösi, Eszter; Veress, György; Ildikó-Márton; Kónya, József

    2011-09-01

    The occurrence of human herpesvirus (HHV) 6 subtypes A and B in apical periodontitis was determined. The relationship of HHV-6 subtypes to other disease associated herpesviruses, i.e., Epstein-Barr virus (EBV) and human cytomegalovirus, was also investigated. Forty apical periodontitis samples (17 symptomatic and 23 asymptomatic) and 40 healthy pulp control samples were collected. Nested polymerase chain reaction was used to detect HHV-6 DNA. HHV-6 DNA was observed in significantly higher frequencies in apical periodontitis samples than in control samples (20% vs. 2.5%; P = .03). Further classification of apical lesions revealed that subtype B of HHV-6 was significantly associated with large-sized and symptomatic lesions (P apical lesions (77%) harbored ≥1 of the tested herpesviruses: EBV was the most frequent herpesvirus (72.5%) in apical periodontitis, followed by HHV-6 (20%). Our findings suggest that EBV and HHV-6B infections can be associated with symptomatic apical periodontitis. Copyright © 2011 Mosby, Inc. All rights reserved.

  13. On the causes of persistent apical periodontitis: a review.

    Science.gov (United States)

    Nair, P N R

    2006-04-01

    Apical periodontitis is a chronic inflammatory disorder of periradicular tissues caused by aetiological agents of endodontic origin. Persistent apical periodontitis occurs when root canal treatment of apical periodontitis has not adequately eliminated intraradicular infection. Problems that lead to persistent apical periodontitis include: inadequate aseptic control, poor access cavity design, missed canals, inadequate instrumentation, debridement and leaking temporary or permanent restorations. Even when the most stringent procedures are followed, apical periodontitis may still persist as asymptomatic radiolucencies, because of the complexity of the root canal system formed by the main and accessory canals, their ramifications and anastomoses where residual infection can persist. Further, there are extraradicular factors -- located within the inflamed periapical tissue -- that can interfere with post-treatment healing of apical periodontitis. The causes of apical periodontitis persisting after root canal treatment have not been well characterized. During the 1990s, a series of investigations have shown that there are six biological factors that lead to asymptomatic radiolucencies persisting after root canal treatment. These are: (i) intraradicular infection persisting in the complex apical root canal system; (ii) extraradicular infection, generally in the form of periapical actinomycosis; (iii) extruded root canal filling or other exogenous materials that cause a foreign body reaction; (iv) accumulation of endogenous cholesterol crystals that irritate periapical tissues; (v) true cystic lesions, and (vi) scar tissue healing of the lesion. This article provides a comprehensive overview of the causative factors of non-resolving periapical lesions that are seen as asymptomatic radiolucencies post-treatment.

  14. Ringed Seal Search for Global Optimization via a Sensitive Search Model.

    Directory of Open Access Journals (Sweden)

    Younes Saadi

    Full Text Available The efficiency of a metaheuristic algorithm for global optimization is based on its ability to search and find the global optimum. However, a good search often requires to be balanced between exploration and exploitation of the search space. In this paper, a new metaheuristic algorithm called Ringed Seal Search (RSS is introduced. It is inspired by the natural behavior of the seal pup. This algorithm mimics the seal pup movement behavior and its ability to search and choose the best lair to escape predators. The scenario starts once the seal mother gives birth to a new pup in a birthing lair that is constructed for this purpose. The seal pup strategy consists of searching and selecting the best lair by performing a random walk to find a new lair. Affected by the sensitive nature of seals against external noise emitted by predators, the random walk of the seal pup takes two different search states, normal state and urgent state. In the normal state, the pup performs an intensive search between closely adjacent lairs; this movement is modeled via a Brownian walk. In an urgent state, the pup leaves the proximity area and performs an extensive search to find a new lair from sparse targets; this movement is modeled via a Levy walk. The switch between these two states is realized by the random noise emitted by predators. The algorithm keeps switching between normal and urgent states until the global optimum is reached. Tests and validations were performed using fifteen benchmark test functions to compare the performance of RSS with other baseline algorithms. The results show that RSS is more efficient than Genetic Algorithm, Particles Swarm Optimization and Cuckoo Search in terms of convergence rate to the global optimum. The RSS shows an improvement in terms of balance between exploration (extensive and exploitation (intensive of the search space. The RSS can efficiently mimic seal pups behavior to find best lair and provide a new algorithm to be

  15. Floating retained root lesion mimicking apical periodontitis.

    Science.gov (United States)

    Chung, Ming-Pang; Chen, Chih-Ping; Shieh, Yi-Shing

    2009-10-01

    A case of a retained root tip simulating apical periodontitis on radiographic examination is described. The retained root tip, originating from the left lower first molar, floated under the left lower second premolar apical region mimicking apical periodontitis. It appeared as an ill-defined periapical radiolucency containing a smaller radiodense mass on radiograph. The differential diagnosis included focal sclerosing osteomyelitis (condensing osteitis) and ossifying fibroma. Upon exicisional biopsy, a retained root associated with granulation tissue was found. After 1-year follow-up, the patient was asymptomatic and the periradicular lesion was healing. Meanwhile, the associated tooth showed a normal response to stimulation testing.

  16. Electronic self-monitoring seal

    International Nuclear Information System (INIS)

    Campbell, J.W.

    1978-01-01

    The Electronic Self-Monitoring Seal is a new type of security seal which allows continuous verification of the seal's identity and status. The identity information is a function of the individual seal, time, and seal integrity. A description of this seal and its characteristics are presented. Also described are the use cycle for the seal and the support equipment for programming and verifying the seal

  17. Inboard seal mounting

    Science.gov (United States)

    Hayes, John R. (Inventor)

    1983-01-01

    A regenerator assembly for a gas turbine engine has a hot side seal assembly formed in part by a cast metal engine block having a seal recess formed therein that is configured to supportingly receive ceramic support blocks including an inboard face thereon having a regenerator seal face bonded thereto. A pressurized leaf seal is interposed between the ceramic support block and the cast metal engine block to bias the seal wear face into sealing engagement with a hot side surface of a rotary regenerator matrix.

  18. Security seal

    Science.gov (United States)

    Gobeli, Garth W.

    1985-01-01

    Security for a package or verifying seal in plastic material is provided by a print seal with unique thermally produced imprints in the plastic. If tampering is attempted, the material is irreparably damaged and thus detectable. The pattern of the imprints, similar to "fingerprints" are recorded as a positive identification for the seal, and corresponding recordings made to allow comparison. The integrity of the seal is proved by the comparison of imprint identification records made by laser beam projection.

  19. Team training using full-scale reactor coolant pump seal mock-ups

    International Nuclear Information System (INIS)

    McDonald, T.J.; Hamill, R.W.

    1987-01-01

    The use of full-scale reactor coolant pump (RCP) seal mock-ups has greatly enhanced Northeast Utilities' ability to effectively utilize the team training approach to technical training. With the advent of the Institute of Nuclear Power Operations accreditation come a new emphasis and standards for the integrated training of plant engineering personnel, maintenance mechanics, quality control personnel, and health physics personnel. The results of purchasing full-scale RCP mock-ups to pilot the concept of team training have far exceeded expectations and cost-limiting factors. The initial training program analysis identified RCP seal maintenance as a task that required training for maintenance department personnel. Due to radiation exposure considerations and the unavailability of actual plant equipment for training purposes, the decision was made to procure a mock-up of an RCP seal assembly and housing. This mock-up was designed to facilitate seal cartridge removal, disassembly, assembly, and installation, duplicating all internal components of the seal cartridge and housing area in exact detail

  20. Mechanical seal program

    International Nuclear Information System (INIS)

    Lowery, G.B.

    1983-01-01

    The experimental plans and timing for completion of the mechanical seal program for both the slurry and transfer pumps are given. The slurry pump seal program will be completed by April 1984 with turnover of two seals in pumps to SRP Tank 15H. Transfer pump seal design will be released for plant use by May 1984. Also included are various other pump and seal related tests

  1. Herpesviruses in asymptomatic apical periodontitis lesions: an immunohistochemical approach.

    Science.gov (United States)

    Saboia-Dantas, C J; Coutrin de Toledo, L F; Sampaio-Filho, H R; Siqueira, J F

    2007-10-01

    Human cytomegalovirus (HCMV) and Epstein-Barr virus (EBV) have been recently detected in samples from apical periodontitis lesions by means of molecular biology techniques and a role in the pathogenesis of this disease has been suggested. The present study was designed to survey asymptomatic primary apical periodontitis lesions for the presence of HCMV- and/or EBV-infected cells by means of immunohistochemistry. Apical periodontitis lesions were obtained from 35 patients [26 human immunodeficiency virus (HIV) -seronegative patients and nine HIV-seropositive patients] after tooth extraction and subjected to immunohistochemical analysis using monoclonal antibodies specific for HCMV and EBV. Fifteen of the 35 apical periodontitis lesions were positive for the target herpesviruses. Overall, EBV was found in 31% of the samples and HCMV in 23%, with 14% of the lesions showing EBV and HCMV dual infection. No association was found between HCMV or EBV with any particular histopathological type of apical periodontitis (P > 0.05). HCMV was significantly more frequent in apical periodontitis lesions from HIV-positive patients (67%) than in lesions from HIV-negative patients (8%) (P = 0.001). EBV was detected in 44% of lesions from HIV-positive patients and in 27% of lesions from HIV-negative patients, but this difference was not significant (P = 0.91). Our results showed that cells infected by HCMV and EBV can be found in apical periodontitis lesions, with a higher prevalence in HIV-positive patients. The specific role that these viruses play in the pathogenesis of apical periodontitis remains to be described.

  2. Secondary seal effects in hydrostatic non-contact seals for reactor coolant pump shaft

    International Nuclear Information System (INIS)

    Fujita, T.; Koga, T.; Tanoue, H.; Hirabayashi, H.

    1987-01-01

    The paper presents a seal flow analysis in a hydrostatic non-contact seal for a PWR coolant pump shaft. A description is given of the non-contact seal for the reactor coolant pump. Results are presented for a distortion analysis of the seal ring, along with the seal flow characteristics and the contact pressure profiles of the secondary seals. The results of the work confirm previously reported findings that the seal ring distortion is sensitive to the o-ring location (which was placed between the ceramic seal face and the seal ring retainer). The paper concludes that the seal flow characteristics and the tracking performance depend upon the dynamic properties of the secondary seal. (U.K.)

  3. Design optimization of seal structure for sealing liquid by magnetic fluids

    International Nuclear Information System (INIS)

    Liu Tonggang; Cheng Yusheng; Yang Zhiyi

    2005-01-01

    The durability of the magnetic fluid seal clearly decreases when sealing another liquid because of the interface instability caused by the applied magnetic field and the velocity difference of the two liquids. With an intention to establish a stable interface during sealing liquid, a new magnetic fluid seal was developed in this paper. The parameters of the structure were optimized by a simulation apparatus. And the magnetic fluid seal designed based on the optimum parameters shows good performance and long life for sealing lubricating oil

  4. Microbiology and Treatment of Acute Apical Abscesses

    Science.gov (United States)

    Rôças, Isabela N.

    2013-01-01

    SUMMARY Acute apical abscess is the most common form of dental abscess and is caused by infection of the root canal of the tooth. It is usually localized intraorally, but in some cases the apical abscess may spread and result in severe complications or even mortality. The reasons why dental root canal infections can become symptomatic and evolve to severe spreading and sometimes life-threatening abscesses remain elusive. Studies using culture and advanced molecular microbiology methods for microbial identification in apical abscesses have demonstrated a multispecies community conspicuously dominated by anaerobic bacteria. Species/phylotypes commonly found in these infections belong to the genera Fusobacterium, Parvimonas, Prevotella, Porphyromonas, Dialister, Streptococcus, and Treponema. Advances in DNA sequencing technologies and computational biology have substantially enhanced the knowledge of the microbiota associated with acute apical abscesses and shed some light on the etiopathogeny of this disease. Species richness and abundance and the resulting network of interactions among community members may affect the collective pathogenicity and contribute to the development of acute infections. Disease modifiers, including transient or permanent host-related factors, may also influence the development and severity of acute abscesses. This review focuses on the current evidence about the etiology and treatment of acute apical abscesses and how the process is influenced by host-related factors and proposes future directions in research, diagnosis, and therapeutic approaches to deal with this disease. PMID:23554416

  5. Bone resorptive activity in symptomatic and asymptomatic apical lesions of endodontic origin.

    Science.gov (United States)

    Salinas-Muñoz, M; Garrido-Flores, M; Baeza, M; Huamán-Chipana, P; García-Sesnich, J; Bologna, R; Vernal, R; Hernández, M

    2017-11-01

    The aim of this study is to assess the levels and diagnostic accuracy of a set of bone resorption biomarkers, including TRAP-5, RANKL, and OPG in symptomatic and asymptomatic apical lesions and controls. Apical tissues from symptomatic and asymptomatic apical periodontitis patients and periodontal ligaments from healthy teeth extracted for orthodontic reasons were processed for tissue homogenization and the levels of TRAP-5, RANKL, and OPG were determined by multiplex assay. Marker levels were analyzed by Kruskal Wallis test, and diagnostic accuracy was analyzed with ROC curves. Higher levels of RANKL, OPG, and RANKL/OPG ratio were determined in both types of apical lesions compared to healthy periodontal ligament, whereas higher TRAP-5 levels were found only in symptomatic apical lesions (p apical lesions versus healthy controls (AUC = 0.69, p asymptomatic apical periodontitis (AUC = 0.71, p Apical lesions showed higher RANKL and OPG levels than healthy tissues. TRAP-5 levels were the highest in symptomatic apical lesions, suggesting that these represent a progressive state, and showed diagnostic potential. Clinically symptomatic apical periodontitis might represent biologically progressive apical lesions based on TRAP5 levels. TRAP5 has diagnostic potential to identify these lesions, representing a candidate prognostic biomarker.

  6. Seal arrangement

    International Nuclear Information System (INIS)

    Dempsey, J.D.

    1978-01-01

    A hydraulically balanced face type shaft seal is provided in which the opening and closing seal face areas retain concentricity with each other in the event of lateral shaft displacement. The seal arrangement is for a vertical high pressure pump, indented for use in the cooling system of a nuclear reactor. (Auth.)

  7. Seroprevalence of Antibodies against Seal Influenza A(H10N7) Virus in Harbor Seals and Gray Seals from the Netherlands.

    Science.gov (United States)

    Bodewes, Rogier; Rubio García, Ana; Brasseur, Sophie M; Sanchez Conteras, Guillermo J; van de Bildt, Marco W G; Koopmans, Marion P G; Osterhaus, Albert D M E; Kuiken, Thijs

    2015-01-01

    In the spring and summer 2014, an outbreak of seal influenza A(H10N7) virus infection occurred among harbor seals (Phoca vitulina) off the coasts of Sweden and Denmark. This virus subsequently spread to harbor seals off the coasts of Germany and the Netherlands. While thousands of seals were reported dead in Sweden, Denmark and Germany, only a limited number of seals were found dead in the Netherlands. To determine the extent of exposure of seals in the Netherlands to influenza A/H10N7 virus, we measured specific antibody titers in serum samples from live-captured seals and seals admitted for rehabilitation in the Netherlands by use of a hemagglutination inhibition assay and an ELISA. In harbor seals in 2015, antibodies against seal influenza A(H10N7) virus were detected in 41% (32 out of 78) pups, 10% (5 out of 52) weaners, and 58% (7 out of 12) subadults or adults. In gray seals (Halichoerus grypus) in 2015, specific antibodies were not found in the pups (n = 26), but in 26% (5 out of 19) of the older animals. These findings indicate that, despite apparent low mortality, infection with seal influenza A(H10N7) virus was geographically widespread and also occurred in grey seals.

  8. [Apical resorption in pre-surgical orthodontics].

    Science.gov (United States)

    Piasente, M; Merlini, C; Amelotti, C; Antonioli, M; Roghi, M

    1991-07-15

    Apical root resorption is a frequent phenomenon observed in pre-surgical orthodontic; the reason is double: we deal with adult patients and we often move the teeth in the opposite direction compared to the position obtained in previous inefficacious orthodontic treatments. Notwithstanding the amount of apical root resorption we couldn't record an hyper-mobility of the teeth and a long term evaluation of occlusal stability didn't show any significant change.

  9. Design of fiber optic electronic seal system based on C8051 microcontroller

    International Nuclear Information System (INIS)

    Di Yuming; Chen Rongye; Zuo Guangxia; Song Cang

    2012-01-01

    This paper presents fiber optic electronic seal system, witch uses C8051 microcontroller as core, matching other circuits such as optical signal detection module, movement detection module, temperature detection module and power module, etc. The results show that the seal system can record the tampering events' information accurately and quickly no matter there is one tamper event or more, and the ability of anti-tamper is improved. (authors)

  10. Evaluation of Bacteriological Profile in the Apical Root Segment of the Patients with Primary Apical Periodontitis.

    Science.gov (United States)

    Tatikonda, Aravind; Sudheep, N; Biswas, Krishna P; Gowtham, K; Pujari, Sudarshan; Singh, Padam

    2017-01-01

    Apical periodontitis usually results from bacterial accumulation and contamination occurring in the root-canal system, and extending beyond the apical foramen to involve the periapical tissues. Literature has a paucity of the studies that stress on the division and analysis of the pulp canal segments. The reason for this disparity might be the technique used for collecting the samples from the pulp canals. Hence, we carried out the present study to evaluate the microbial flora in the apical part of the roots with necrotic pulp canals. The present study included the assessment of 40 freshly extracted teeth that had necrotized pulpal tissue along with the presence of periapical periodontal lesions. Removal of the soft tissue lesions attached to the root portion of the teeth along with apical periodontal lesions was done with the help of scalpel blade, after rinsing them with a sterile solution of saline. Thorough cleaning of the root surfaces was done with hydrogen peroxide followed by rapid disinfection with the help of sodium hypochlorite at varying concentrations. Sectioning of the root portion of all the specimens with the help of a disk was done perpendicular to the long axis of the teeth at a distance of roughly 5 to 6 mm from the teeth's apicalmost point. Cryotubes were used for transferring the specimens of apical portions containing 1 mL of buffer and were subjected to immediate frozen processing at a temperature of -20°C. A 10 K-type file was used for the initial collection of the samples followed by subsequent incubation of the files and paper pints in the incubation cabinet. Subsequent deoxyribonucleic acid (DNA) extraction from the samples was done following the procedure described by Siqueira et al. Paster et al's modification of the reverse-capture checkerboard assay was used in the present study. Semiquantitative data were used for overcoming the difficulties arising due to obtaining the counts of the polymerase chain reaction (PCR)-based analysis of

  11. Frequency and levels of candidate endodontic pathogens in acute apical abscesses as compared to asymptomatic apical periodontitis

    OpenAIRE

    Rôças, Isabela N.; Siqueira, José F.

    2018-01-01

    Introduction Acute apical abscess is caused by bacteria that leave the infected dental root canal to invade the periodontal tissues. Most species occurring in abscesses are also found in asymptomatic infections; therefore, the possibility exists that not only the presence of certain species but also their specific counts influence the appearance of symptoms. This molecular study compared the frequency and levels of several candidate endodontic pathogens in teeth with acute apical abscesses an...

  12. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths.

    Science.gov (United States)

    Liu, Rui; Kaiwar, Anjali; Shemesh, Hagay; Wesselink, Paul R; Hou, Benxiang; Wu, Min-Kai

    2013-01-01

    The aim of this study was to compare the incidence of apical root cracks and dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Two hundred forty mandibular incisors were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. The root canals were instrumented with rotary and hand files, namely K3, ProTaper, and nickel-titanium Flex K files to the major apical foramen (AF), short AF, or beyond AF. Digital images of the apical surface of every tooth were taken during the apical enlargement at each file change. Development of dentinal defects was determined by comparing these images with the baseline image. Multinomial logistic regression test was performed to identify influencing factors. Apical crack developed in 1 of 80 teeth (1.3%) with hand files and 31 of 160 teeth (19.4%) with rotary files. Apical dentinal detachment developed in 2 of 80 teeth (2.5%) with hand files and 35 of 160 teeth (21.9%) with rotary files. Instrumentation with rotary files terminated 2 mm short of AF and did not cause any cracks. Significantly less cracks and detachments occurred when instrumentation with rotary files was terminated short of AF, as compared with that terminated at or beyond AF (P hand instruments; instrumentation short of AF reduced the risk of dentinal defects. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Seal design alternatives study

    International Nuclear Information System (INIS)

    Van Sambeek, L.L.; Luo, D.D.; Lin, M.S.; Ostrowski, W.; Oyenuga, D.

    1993-06-01

    This report presents the results from a study of various sealing alternatives for the WIPP sealing system. Overall, the sealing system has the purpose of reducing to the extent possible the potential for fluids (either gas or liquid) from entering or leaving the repository. The sealing system is divided into three subsystems: drift and panel seals within the repository horizon, shaft seals in each of the four shafts, and borehole seals. Alternatives to the baseline configuration for the WIPP seal system design included evaluating different geometries and schedules for seal component installations and the use of different materials for seal components. Order-of-magnitude costs for the various alternatives were prepared as part of the study. Firm recommendations are not presented, but the advantages and disadvantages of the alternatives are discussed. Technical information deficiencies are identified and studies are outlined which can provide required information

  14. Sealing of ceramic SOFC-components with glass seals; Fuegen von keramischen Komponenten der Hochtemperatur-Brennstoffzellen mittels Glas- und Glaskeramikloten

    Energy Technology Data Exchange (ETDEWEB)

    Schillig, Cora

    2012-07-10

    The solid oxide fuel cell (SOFC) converts chemical energy of a fuel directly into electrical energy. However, for the implementation of SOFC-technology in competition to conventional power plants costs have to be reduced. The use of an alternative tubular cell design without closed end would allow reducing costs during cell manufacturing. However, this change in design makes a gastight sealing inside the generator near the gas inlet necessary. Different ceramic materials with varying coefficients of thermal expansion have to be sealed gastight and electrical insulating at temperatures between 850 C and 1000 C to prevent the gases from mixing and an electrical shortcut between the cells. This work comprises analysis of commercially available glass and glass-ceramic systems manufactured by Schott Electronic Packaging, Areva T and D and Ferro Corporation. Additionally new developed sealing glass and glass-ceramic systems were investigated and all systems were characterized fundamentally for the use as sealing material in SOFC generators. Therefore different test assemblies and series were conducted. Essential characteristics of a suitable sealing system are a thermal expansion coefficient between 9,5 and 12 . 10{sup -6}K{sup -1}, a viscosity in the range between 10{sup 4} to 10{sup 6} dPa{sup *}s and a wetting angle smaller than 90 during the sealing process. Also unwanted chemical side reactions between the sealing partners must be prevented, because a change in the phase composition or the creation of new phases in the sealing material could endanger the stability of the seal. Heat cycles, particularly those during generator operation, cause deterioration of the sealing material and subsequent reduction in its ability to prevent mixing of the gases. Sealant leaks can drastically impact efficiency of the generator. In order to ensure optimum operation low leak rates around 2,3 . 10{sup -4} mbar l/sec/cm{sup 2} must be maintained. Especially glass and glass

  15. Racing performance after arthroscopic removal of apical sesamoid fracture fragments in Thoroughbred horses age > or = 2 years: 84 cases (1989-2002).

    Science.gov (United States)

    Schnabel, L V; Bramlage, L R; Mohammed, H O; Embertson, R M; Ruggles, A J; Hopper, S A

    2006-09-01

    Studies have shown that surgical removal of apical fracture fragments in Standardbred racehorses carries the best prognosis for return to racing performance, but there are no reports involving mature Thoroughbred (TB) racehorses. To describe the incidence of apical proximal sesamoid fractures in TB racehorses and determine probability and quality of racing performance after arthroscopic removal of such fractures in TB racehorses age > or = 2 years. Medical records and pre- and post operative race records of TB racehorses age > or = 2 years that underwent arthroscopic surgery for removal of apical proximal sesamoid fracture fragments were reviewed. Sixty-four percent of fractures occurred in the hindlimbs and 36% in the forelimbs. Horses with forelimb fractures had a reduced probability of return to racing (67%) compared to those with hindlimb fractures (83%), but the majority (77%) of treated horses recovered to return to race post operatively. Horses with medial forelimb fractures raced at only a 47% rate; those with suspensory desmitis at 63%. Unlike Standardbreds, there was no difference in probability of racing post operatively between horses that had, and had not, raced preoperatively. Data show that arthroscopic removal of apical proximal sesamoid fracture fragments is successful at restoring ability to race in skeletally mature TB horses without evidence of severe suspensory ligament damage. Prognosis for return to racing is excellent (83%) in horses with hindlimb fractures and good (67%) in those with forelimb fractures. Medial fractures of the forelimb have the worst prognosis. The determination of prognosis for differing sites in TB racehorses should increase knowledge of apical proximal sesamoid bone fractures and improve communication from veterinarian to owner, and trainer, on the potential for arthroscopic restoration of the ability to race.

  16. Nuclear waste vault sealing

    International Nuclear Information System (INIS)

    Gyenge, M.

    1980-01-01

    A nuclear waste vault must be designed and built to ensure adequate isolation of the nuclear wastes from human contact. Consequently, after a vault has been fully loaded, it must be adequately sealed off to prevent radionuclide migration which may be provided by circulating groundwater. Vault sealing entails four major aspects, i.e.: (a) vault grouting; (b) borehole sealing; (c) buffer packing; and (d) backfilling. Of particular concern in vault sealing are the physical and chemical properties of the sealing material, its long-term durability and stability, and the techniques used for its emplacement. Present sealing technology and sealing materials are reviewed in terms of the particular needs of vault sealing. Areas requiring research and development are indicated

  17. Nozzle seal

    International Nuclear Information System (INIS)

    Herman, R.F.

    1977-01-01

    In an illustrative embodiment of the invention, a nuclear reactor pressure vessel, having an internal hoop from which the heated coolant emerges from the reactor core and passes through to the reactor outlet nozzles, is provided with sealing members operatively disposed between the outlet nozzle and the hoop. The sealing members are biased against the pressure vessel and the hoop and are connected by a leak restraining member establishing a leak-proof condition between the inlet and outlet coolants in the region about the outlet nozzle. Furthermore, the flexible responsiveness of the seal assures that the seal will not structurally couple the hoop to the pressure vessel

  18. Nozzle seal

    International Nuclear Information System (INIS)

    Walling, G.A.

    1977-01-01

    In an illustrative embodiment of the invention, a nuclear reactor pressure vessel, having an internal hoop from which the heated coolant emerges from the reactor core and passes through to the reactor outlet nozzles, is provided with sealing rings operatively disposed between the outlet nozzles and the hoop. The sealing rings connected by flexible members are biased against the pressure vessel and the hoop, establishing a leak-proof condition between the inlet and outlet coolants in the region about the outlet nozzle. Furthermore, the flexible responsiveness of the seal assures that the seal will not structurally couple the hoop to the pressure vessel. 4 claims, 2 figures

  19. Root Canal Microorganism Profiles on Upper Anterior Teeth of Apical Periodontitis

    OpenAIRE

    Riuwpassa, E. Irene

    2013-01-01

    Microorganisms are the main causative agents on the development of apical periodontitis. Microorganisms infecting the root canal system are colonized in communities as biofilm. These bacterial communities show distinct pattern related to the different forms of apical periodontitis which are determined by species richness and abundance.this study is aimed to examine the root canal microorganisms on upper anterior teeth of asymptomatic apical periodontitis and chronic apical abscess. Samples we...

  20. Bony change of apical lesion healing process using fractal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Min; Park, Hyok; Jeong, Ho Gul; Kim, Kee Deog; Park, Chang Seo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2005-06-15

    To investigate the change of bone healing process after endodontic treatment of the tooth with an apical lesion by fractal analysis. Radiographic images of 35 teeth from 33 patients taken on first diagnosis, 6 months, and 1 year after endodontic treatment were selected. Radiographic images were taken by JUPITER computerized Dental X-ray System. Fractal dimensions were calculated three times at each area by Scion Image PC program. Rectangular region of interest (30 x 30) were selected at apical lesion and normal apex of each image. The fractal dimension at apical lesion of first diagnosis (L{sub 0}) is 0.940 {+-} 0.361 and that of normal area (N{sub 0}) is 1.186 {+-} 0.727 (p<0.05). Fractal dimension at apical lesion of 6 months after endodontic treatment (L{sub 1}) is 1.076 {+-} 0.069 and that of normal area (N{sub 1}) is 1.192 {+-} 0.055 (p<0.05). Fractal dimension at apical lesion of 1 year after endodontic treatment (L{sub 2}) is 1.163 {+-} 0.074 and that of normal area (N{sub 2}) is 1.225 {+-} 0.079 (p<0.05). After endodontic treatment, the fractal dimensions at each apical lesions depending on time showed statistically significant difference. And there are statistically significant different between normal area and apical lesion on first diagnosis, 6 months after, 1 year after. But the differences were grow smaller as time flows. The evaluation of the prognosis after the endodontic treatment of the apical lesion was estimated by bone regeneration in apical region. Fractal analysis was attempted to overcome the limit of subjective reading, and as a result the change of the bone during the healing process was able to be detected objectively and quantitatively.

  1. Flexible ring seal

    International Nuclear Information System (INIS)

    Abbes, Claude; Gournier, Andre; Rouaud, Christian; Villepoix, Raymond de.

    1976-01-01

    The invention concerns a flexible metal ring seal, able to ensure a perfect seal between two bearings due to the crushing and elastic deformation properties akin to similar properties in elastomers. Various designs of seal of this kind are already known, particularly a seal made of a core formed by a helical wire spring with close-wound turns and with high axial compression ratio, closed on itself and having the shape of an annulus. This wire ring is surrounded by at least one envelope having at rest the shape of a toroidal surface of which the generating circle does not close on itself. In a particular design mode, the seal in question can include, around the internal spring, two envelopes of which one in contact with the spring is composed of a low ductility elastic metal, such as mild steel or stainless steel and the other is, on the contrary, made of a malleable metal, such as copper or nickel. The first envelope evenly distributes the partial crushing of the spring, when the seal is tightened, on the second envelope which closely fits the two surfaces between which the seal operates. The stress-crushing curve characteristic of the seal comprises two separate parts, the first with a relatively sharp slope corresponds to the start of the seal compression phase, enabling at least some of these curves to reach the requisite seal threshold very quickly, then, beyond this, a second part, practically flat, where the stress is appreciably constant for a wide operating bracket [fr

  2. Active Infrared Thermography for Seal Contamination Detection in Heat-Sealed Food Packaging

    Directory of Open Access Journals (Sweden)

    Karlien D’huys

    2016-11-01

    Full Text Available Packaging protects food products from environmental influences, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the quality of the packaging material and of the closure or seal. A common problem possibly jeopardizing seal quality is the presence of seal contamination, which can cause a decreased seal strength, an increased packaging failure risk and leak formation. Therefore, early detection and removal of seal contaminated packages from the production chain is crucial. In this work, a pulsed-type active thermography method using the heated seal bars as an excitation source was studied for detecting seal contamination. Thermal image sequences of contaminated seals were recorded shortly after sealing. The detection performances of six thermal image processing methods, based on a single frame, a fit of the cooling profiles, thermal signal reconstruction, pulsed phase thermography, principal component thermography and a matched filter, were compared. High resolution digital images served as a reference to quantify seal contamination, and processed thermal images were mapped to these references. The lowest detection limit (equivalent diameter 0.60 mm was obtained for the method based on a fit of the cooling profiles. Moreover, the detection performance of this method did not depend strongly on the time after sealing at which recording of the thermal images was started, making it a robust and generally applicable method.

  3. Nuclear reactor sealing system

    International Nuclear Information System (INIS)

    McEdwards, J.A.

    1983-01-01

    A liquid metal-cooled nuclear reactor sealing system is disclosed. The nuclear reactor includes a vessel sealed at its upper end by a closure head. The closure head comprises at least two components, one of which is rotatable; and the two components define an annulus therebetween. The sealing system includes at least a first and second inflatable seal disposed in series in an upper portion of the annulus. The system further includes a dip seal extending into a body of insulation located adjacent a bottom portion of the closure head. The dip seal comprises a trough formed by a lower portion of one of the components, and a seal blade pendently supported from the other component and extending downwardly into the trough. A body of liquid metal is contained in the trough which submerges a portion of the seal blade. The seal blade is provided with at least one aperture located above the body of liquid metal for providing fluid communication between the annulus intermediate the dip seal and the inflatable seals, and a body of cover gas located inside the vessel. There also is provided means for introducing a purge gas into the annulus intermediate the inflatable seals and the seal blade. The purge gas is introduced in an amount sufficient to substantially reduce diffusion of radioactive cover gas or sodium vapor up to the inflatable seals. The purge gas mixes with the cover gas in the reactor vessel where it can be withdrawn from the vessel for treatment and recycle to the vessel

  4. The IRES electronic seal

    International Nuclear Information System (INIS)

    Autrusson, B.; Brochard, D.; Moreau, J.F.; Martin, J.C.

    2001-01-01

    In the framework of the French Support Program for the IAEA Safeguards, the 'Institut de Protection et de Surete Nucleaire' (IPSN), developed an electronic seal called Integrated and Reusable Electronic Seal (IRES) that enables independent verification by different inspectorates (IAEA, Euratom, and National Inspectorate). The seal can be remotely interrogated by radio frequency and integrated to other Containment/surveillance systems by serial line RS 485. Data are authenticated and the IRESMAG software manages in the seal reader all functionalities of the seal and records inspection data compatible with the IAEA's Seal Database. To perform this development, IPSN relies on industrial partners: SAPHYMO for the general architecture of the seal and the electronics, THALES for the authentication of data and the security of transmission. The main features of the IRES seal are the following: Interrogation by different inspectorate, allowing independent conclusions; Recording of events, including tampering, in a non-volatile memory; Authentication of data and enhanced security of the communication between the seal and the seal reader; Remote interrogation by an inspector or/and automatic for unattended systems or remote monitoring; Reusable after erasing the seal memory and replacement of the batteries

  5. Compliant seal development

    Science.gov (United States)

    Hendricks, Robert C.

    1993-10-01

    The compliant metallic seal combines the noncontact feature of the labyrinth seal, the low leakage of a mechanical seal, and the compliant nature of the brush seal. It consists of several thin metallic elements or leaves mounted within a ring which is press fit into the housing, and in form, sort of resembles a lip seal sections wiping the shaft. A second set of overlapping cover leaves are placed on top of the shaft riding leaves which reduces leakage and provides stiffness. The leaves can be straight or angle cut. The shaft riding fingers are designed with mismatched curvature to provide lift off similar to the Rayleigh lift pads in mechanical seals with leading edge clearances nearly twice those of the trailing edge as as shown by Fleming to be optimal for gas flows in convergent seal passages. Leading edge clearances range from 300 to 500 microinches. Balance pockets beneath the leaves provide fluid film feed to the 'Rayleigh lift' surface and the proper balance ratio (mechanical seal) when combined with the static pressure and film pressure. The leaves flex in the radial direction and accommodate thermomechanical behavior as well as axial motion and angular misalignment. In the static mode, there is a net closing force on the leaves. The seals were tested to 70 psi at speeds to 16,000 rpm or surface speeds to 330 fps and temperatures from ambient to 440 F. A slow cycle through the rig critical at 10,000 rpm induced a radial vibration response of 0.004 to 0.005 inch were accommodated by the seal. Preliminary performance data are encouraging demonstrating hydrodynamic liftoff and noncontacting operation at pressure and speeds typical of gas turbine engines. The leakage performance data are significantly better than commercial labyrinth and brush seals which should be expected as this design incorporates the features of the low leakage face or mechanical seal along with the flexibility of the brush configuration.

  6. Self-acting shaft seals

    Science.gov (United States)

    Ludwig, L. P.

    1978-01-01

    Self-acting seals are described in detail. The mathematical models for obtaining a seal force balance and the equilibrium operating film thickness are outlined. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis reveals three different vibration models with secondary seal friction being an important parameter. Leakage flow inlet pressure drop and affects of axisymmetric sealing face deformations are discussed. Experimental data on self-acting face seals operating under simulated gas turbine conditions are given. Also a spiral groove seal design operated to 244 m/sec (800 ft/sec) is described.

  7. HMSRP Hawaiian Monk Seal Master Identification Records (seal)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records of all individually identified Hawaiian monk seals since 1981. These seals were identified by PSD personnel and cooperating scientists...

  8. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  9. Hermetically Sealed Compressor

    Science.gov (United States)

    Holtzapple, Mark T.

    1994-01-01

    Proposed hermetically sealed pump compresses fluid to pressure up to 4,000 atm (400 MPa). Pump employs linear electric motor instead of rotary motor to avoid need for leakage-prone rotary seals. In addition, linear-motor-powered pump would not require packings to seal its piston. Concept thus eliminates major cause of friction and wear. Pump is double-ended diaphragm-type compressor. All moving parts sealed within compressor housing.

  10. Apical Revascularization after Delayed Tooth Replantation: An Unusual Case

    Directory of Open Access Journals (Sweden)

    Marília Pacífico Lucisano

    2016-01-01

    Full Text Available The aim of this paper is to present the clinical and radiological outcome of the treatment involving a delayed tooth replantation after an avulsed immature permanent incisor, with a follow-up of 1 year and 6 months. An 8-year-old boy was referred after dental trauma that occurred on the previous day. The permanent maxillary right central incisor (tooth 11 had been avulsed. The tooth was hand-held during endodontic therapy and an intracanal medication application with calcium hydroxide-based paste was performed. An apical plug with mineral trioxide aggregate (MTA was introduced into the apical portion of the canal. When the avulsed tooth was replanted with digital pressure, a blood clot had formed within the socket, which moved the MTA apical plug about 2 mm inside of the root canal. These procedures developed apical revascularization, which promoted a successful endodontic outcome, evidenced by apical closure, slight increase in root length, and absence of signs of external root resorption, during a follow-up of 1 year and 6 months.

  11. Reinforced seal component

    International Nuclear Information System (INIS)

    Jeanson, G.M.; Odent, R.P.

    1980-01-01

    The invention concerns a seal component of the kind comprising a soft sheath and a flexible reinforcement housed throughout the entire length of the sheath. The invention enables O ring seals to be made capable of providing a radial seal, that is to say between two sides or flat collars of two cylindrical mechanical parts, or an axial seal, that is to say between two co-axial axisymmetrical areas. The seal so ensured is relative, but it remains adequately sufficient for many uses, for instance, to ensure the separation of two successive fixed blading compartments of axial compressors used in gas diffusion isotope concentration facilities [fr

  12. Numerical Investigation of the Effect of Radial Lip Seal Geometry on Sealing Performance

    Science.gov (United States)

    Tok, G.; Parlar, Z.; Temiz, V.

    2018-01-01

    Sealing elements are often needed in industry and especially in machine design. With the change and development of machine technology from day to day, sealing elements show continuous development and change in parallel with these developments. Many factors influence the performance of the sealing elements such as shaft surface roughness, radial force, lip geometry etc. In addition, the radial lip seals must have a certain pre-load and interference in order to provide a good sealing. This also affects the friction torque. Researchers are developing new seal designs to reduce friction losses in mechanical systems. In the presented study, the effect of the lip seal geometry on sealing performance will be examined numerically. The numerical model created for this purpose will be verified with experimental data firstly. In the numerical model, shaft and seal will be modeled as hyper-elastic in 2D and 3D. NBR (Nitrile Butadiene Rubber) as seal material will be analyzed for the rotating shaft state at constant speed by applying a uniform radial force.

  13. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  14. High pressure shaft seal

    International Nuclear Information System (INIS)

    Martinson, A.R.; Rogers, V.D.

    1980-01-01

    In relation to reactor primary coolant pumps, mechanical seal assembly for a pump shaft is disclosed which features a rotating seal ring mounting system which utilizes a rigid support ring loaded through narrow annular projections in combination with centering non-sealing O-rings which effectively isolate the rotating seal ring from temperature and pressure transients while securely positioning the ring to adjacent parts. A stationary seal ring mounting configuration allows the stationary seal ring freedom of motion to follow shaft axial movement up to 3/4 of an inch and shaft tilt about the pump axis without any change in the hydraulic or pressure loading on the stationary seal ring or its carrier. (author)

  15. Does the seal licensing system in Scotland have a negative impact on seal welfare?

    Directory of Open Access Journals (Sweden)

    Laetitia Nunny

    2016-08-01

    Full Text Available This study examined the licensing system that permits seal shooting in Scotland, which was established under Part 6 Conservation of Seals of the Marine (Scotland Act 2010. Four approaches were used: data were collated and analyzed from both the Scottish Government and Scottish Marine Animal Stranding Scheme; a survey was sent to current license holders and informal interviews were conducted with key stakeholder types. Between February 2011 and the end of October 2015, 1229 gray seals and 275 common seals were reported shot under license to the Scottish Government. The numbers of seals reported as shot has reduced year-on-year since the licensing system was put in place. While some license holders, notably fish farms, were using some non-lethal forms of deterrent to reduce seal-related damage, these were often used alongside seal shooting. Of the seals reported as shot to the Scottish Government, only a small percentage were also reported to the Scottish Marine Animal Stranding Scheme, despite this being a licensing requirement. Only 2.3% of the shot gray seals and 4.5% of the shot common seals were necropsied. There is evidence from these necropsies that some seals had not died instantly or had not been shot in the manner recommended by the Scottish Seal Management Code of Practice. These preliminary results show that more carcasses need to be recovered and necropsied if the welfare implications of current seal shooting practice are to be properly assessed. The current legislation does not specify closed seasons to protect breeding seals and thirty-five per cent of necropsied seals were pregnant gray seals. Seals have also been shot during their lactation periods when pups are dependent on their mothers. This raises significant welfare concerns. The re-introduction of closed seasons specific to each species of seal is recommended along with greater effort to deploy non-lethal methods. Independent assessment of the number of seals being killed

  16. SSME Seal Test Program: Test results for sawtooth pattern damper seal

    Science.gov (United States)

    Childs, D. W.

    1986-01-01

    Direct and transverse force coefficients for 11, sawtooth-pattern, and damper-seal configurations were examined. The designation damper seal uses a deliberately roughened stator and smooth rotor to increase the net damping force developed by a seal. The designation sawtooth-pattern refers to a stator roughness pattern. The sawtooth pattern yields axial grooves in the stator which are interrupted by spacer elements which act as flow constrictions or dams. All seals use the same smooth rotor and have the same, constant, minimum clearance. The stators examined the consequences of changes in the following design parameters: (1) axial-groove depth; (2) number of teeth: (3) number of sawtooth sections; (4) number of spacer elements; (5) dam width; (6) axially aligned sawtooth sections versus axially-staggered sawtooth sections; and (7) groove geometry. It is found that none of the sawtooth-pattern seal performs as well as the best round-hole-pattern seal. Maximum damping configurations for the sawtooth and round-hole-pattern stators have comparable stiffness performance. Several of the sawtooth pattern stators outperformed the best round-hole pattern seal.

  17. Circumferential shaft seal

    Science.gov (United States)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A circumferential shaft seal comprising two sealing rings held to a rotating shaft by means of a surrounding elastomeric band is disclosed. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  18. Sealing arrangement for radioactive material

    International Nuclear Information System (INIS)

    Gray, I.L.S.; Sievwright, R.W.T.; Elliott, J.C.

    1993-01-01

    A sealing arrangement for hermetically sealing two mating surfaces comprises two seals arranged to lie between the surfaces. Each seal provides hermetic sealing over a respective different temperature range and lie serially along the surfaces between the regions to be isolated. A main seal integrity test arrangement is provided in the form of a port and passage. This allows for the introduction of a fluid into or the evacuation of a region between the two seals to detect a leak. The port is also provided with at least two test port seals which seal with a plug. The plug is also provided with a test port to allow the integrity of the test port seal to be tested. (UK)

  19. Severe service sealing solutions

    International Nuclear Information System (INIS)

    Metcalfe, R.; Wensel, R.

    1994-09-01

    Successful sealing usually requires much more than initial leak-tightness. Friction and wear must also be acceptable, requiring a good understanding of tribology at the sealing interface. This paper describes various sealing solutions for severe service conditions. The CAN2A and CAN8 rotary face seals use tungsten carbide against carbon-graphite to achieve low leakage and long lifetime in nuclear main coolant pumps. The smaller CAN6 seal successfully uses tungsten carbide against silicon carbide in reactor water cleanup pump service. Where friction in CANDU fuelling machine rams must be essentially zero, a hydrostatic seal using two silicon carbide faces is the solution. In the NRU reactor moderator pumps, where pressure is much lower, eccentric seals that prevent boiling at the seal faces are giving excellent service. All these rotary face seals rely on supplementary elastomer seals between their parts. An integrated engineering approach to high performance sealing with O-rings is described. This is epitomized in critical Space Shuttle applications, but is increasingly being applied in CANDU plants. It includes gland design, selection and qualification of material, quality assurance, detection of defects and the effects of lubrication, surface finish, squeeze, stretch and volume constraints. In conclusion, for the severe service applications described, customized solutions have more than paid for themselves by higher reliability, lower maintenance requirements and reduced outage time. (author)

  20. Research on seal control systems for international nuclear safeguard and the vulnerability assessment on the seals

    International Nuclear Information System (INIS)

    Zhang Hongjian; Liu Tianshu; Cao Fangfang; Xu Chunyan

    2014-01-01

    Safeguard seals, also called Tamper-indicating devices (TIDs), are widely used to detect tampering or unauthorized entry in the international safeguard and security systems, Seal control systems consist of seal implementing plan, seal development and the vulnerability assessment on tbe seals, effective implementing procedures and methods of the seals. The vulnerability assessment contents of safeguard seals, thermo-shrinked film seals being as an example, and seals control systems in the implementation program are researched. The seal control systems discuss task assignment, seals management flow and seals program data flow to promote applying effectively seals. The vulnerability assessment program of seals studies assurance level to some different tampering techniques and measures. The researches must promote utilizing seals effectively for nuclear security, non-proliferation of nuclear weapons, radioactive waste management, and the nuclear material accounting and control. (authors)

  1. Intraoral Temperature Triggered Shape-Memory Effect and Sealing Capability of A Transpolyisoprene-Based Polymer

    Directory of Open Access Journals (Sweden)

    Gakuji Tsukada

    2015-11-01

    Full Text Available In dentistry, pure gutta-percha (trans-1,4-polyisoprene (TPI is widely used as a main component of root canal filling materials. TPI has an interesting shape memory formed through cross-linking, and this characteristic is expected to be very effective for development of novel dental treatments; in particular, modification of the shape recovery temperature to the intraoral temperature (37 °C will enhance the applicability of the shape-memory effect of TPI in root canal filling. In this study, trial test specimens consisting of varying proportions of TPI, cis-polyisoprene, zinc oxide, stearic acid, sulfur and dicumyl peroxide were prepared and the temperature dependence of their shape recovery, recovery stress and relaxation modulus were measured. Additionally, their sealing abilities were tested using glass tubing and a bovine incisor. As the ratio of cross-linking agent in the specimens increased, a decrease in recovery temperature and an increase in recovery stress and recovery speed were observed. In addition, the test specimen containing the highest concentration of cross-linking agent showed superior sealing ability under a thermal stimulus of 37 °C in both sealing ability tests.

  2. The IRES electronic seal

    International Nuclear Information System (INIS)

    Gourlez, P.; Funk, P.; Brochard, D.; Moreau, J.F.; Martin, J.C.

    2001-01-01

    In the framework of the French Support Program for the IAEA Safeguards, the 'Institut de Protection et de Surete Nucleaire' (IPSN), developed an electronic seal called Integrated and Reusable Electronic Seal (IRES) that enables independent verification by different inspectorates (IAEA, Euratom, and National Inspectorate) Furthermore, a bilateral co-ordination between Euratom and French domestic safeguards takes place in some French facilities regarding a common approach concerning the seals especially in case of crisis situation. The seal can be remotely interrogated by radio frequency and integrated to other Containment/surveillance systems by serial line RS 485. Data are authenticated and the IRESMAG software manages in the seal reader all functionalities of the seal and records inspection data compatible with the IAEA's Seal Database

  3. Cover-gas-seal component development: dynamic inflatable-plug seal improvement

    International Nuclear Information System (INIS)

    Horton, P.H.

    1977-01-01

    This report documents the 1) radial compliance and 2) low friction coating tests conducted on the CRBRP Rotating Plug Inflatable Seals per test plan N707TR810014. Test results show that narrowing the seal blade from 0.25 to 0.12 in. will effectively reduce dynamic drag from 30 to 20 lb/ft under nominal conditions and will increase seal radial compliance from 0.12 to 0.30 in. without an unacceptable rise in dynamic drag. Tests also demonstrated that application of a teflon coating to the seal wear surface reduced breakaway drag by 25% based on results of comparison dwells

  4. Effect of bar sealing parameters on OPP/MCPP heat seal strength

    Directory of Open Access Journals (Sweden)

    2007-11-01

    Full Text Available The effect of bar sealing parameters on the heat seal strength of oriented polypropylene (OPP/metallic cast polypropylene (MCPP laminate film was investigated. Based on the results obtained from the parametric study, a bar sealing process window was developed. All points drop within the process window are combinations of platen temperature and dwell time that produce acceptable heat seal. Optimum combinations are indicated by the lower border of the window. The plateau initiation temperature, Tpi of OPP/MCPP laminate film used in the present study occurred before the final melting temperature, Tmf of the sealant material. The highest achievable heat seal strength was at the plateau region, and the corresponding failure modes were delaminating, tearing or combine failure modes (delaminating and tearing. Minimum pressure level of 1.25 bars is necessary to bring the laminate interface into intimate contact in order to effect sealing.

  5. Comparative study on two different seal surface structure for reactor pressure vessel sealing behavior

    International Nuclear Information System (INIS)

    Chen Jun; Xiong Guangming; Deng Xiaoyun

    2014-01-01

    The seal surface structure is very important to reactor pressure vessel (RPV) sealing behavior. In this paper, two 3-D RPV sealing analysis finite models have been established with different seal surface structures, in order to study the influence of two structures. The separation of RPV upper and lower flanges, bolt loads and etc. are obtained, which are used to evaluate the sealing behavior of the RPV. Meanwhile, the comparative analysis of safety margin of two seal surface structural had been done, which provides the theoretical basis for RPV seal structure design optimization. (authors)

  6. Seals in motion

    NARCIS (Netherlands)

    Brasseur, Sophie Marie Jacqueline Michelle

    2017-01-01

    The harbour seal Phoca vitulina and the grey seal Halichoerus grypus have been inhabitants of the Wadden Sea since millennia. Prehistoric findings indicate the presence of both species around 5000 BC. This changed dramatically in the mid Middle-Ages as around 1500 AC, the grey seal disappeared from

  7. Design and development of face seal type sealing plug for advanced heavy water reactor

    International Nuclear Information System (INIS)

    Bansal, S.; Bhattacharyya, S.; Patel, R.J.; Agrawal, R.G.; Vaze, K.K.

    2005-09-01

    Advanced Heavy Water Reactor is a vertical pressure tube type reactor having light water as its coolant and heavy water as moderator. Sealing plug is required to close the pressure boundary of main heat transport system of the reactor by preventing escape of light water/steam From the coolant channel. There are 452 coolant channels in the reactor located in square lattice pitch. Sealing plug is located at the top of each coolant channel (in the top end fitting). Top end fitting is having a stepped bore to create a sealing face. Sealing plug is held through its expanded jaws in a specially provided groove of the end fitting. The plug was designed and prototypes were manufactured considering its functional importance, intricate design and precision machining requirements. Sealing plug consists of about 20 components mostly made up of precipitation hardening stainless steel, which is suitable for water environment and meets other requirements of strength and resistance to wear and galling. Seal disc is a critical component of the sealing plug as it is the pressure-retaining component. It is a circular disc with protruded stem. One face of the seal disc is nickel plated in the peripheral area that creates the sealing by abutting against the sealing face provided in the end fitting. The typical shape and profile of seal disc provides flexibility and allows elastic deformation to assist in locking of sealing plug and creating adequate seating force for effective sealing. Design and development aspects of the sealing plug have been detailed out in this report. Also results of stress analysis and experimental studies for seal disc have been mentioned in the report. Stress analysis and experimental testing was required for the seal disc because high stresses are developed due to its exposure to high pressure and temperature environment of Main Heat Transport system. Hot testing was carried out to simulate the reactor-simulated condition. The performance was found to be

  8. Cover gas seals. 11 - FFTF-LMFBR seal-test program, January-March 1974

    International Nuclear Information System (INIS)

    Kurzeka, W.; Oliva, R.; Welch, F.

    1974-01-01

    The objectives of this program are to: (1) conduct static and dynamic tests to demonstrate or determine the mechanical performance of full-size (cross section) FFTF fuel transfer machine and reactor vessel head seals intended for use in a sodium vapor - inert gas environment, (2) demonstrate that these FFTF seals or new seal configuration provide acceptable fission product and cover gas retention capabilities at LMFBR Clinch River Plant operating environmental conditions other than radiation, and (3) develop improved seals and seal technology for the LMFBR Clinch River Plant to support the national objective to reduce all atmospheric contaminations to low levels

  9. In vitro sealing of iatrogenic fetal membrane defects by a collagen plug imbued with fibrinogen and plasma.

    Science.gov (United States)

    Engels, A C; Hoylaerts, M F; Endo, M; Loyen, S; Verbist, G; Manodoro, S; DeKoninck, P; Richter, J; Deprest, J A

    2013-02-01

    We aimed to demonstrate local thrombin generation by fetal membranes, as well as its ability to generate fibrin from fibrinogen concentrate. Furthermore, we aimed to investigate the efficacy of collagen plugs, soaked with plasma and fibrinogen, to seal iatrogenic fetal membrane defects. Thrombin generation by homogenized fetal membranes was measured by calibrated automated thrombography. To identify the coagulation caused by an iatrogenic membrane defect, we analyzed fibrin formation by optical densitometry, upon various concentrations of fibrinogen. The ability of a collagen plug soaked with fibrinogen and plasma was tested in an ex vivo model for its ability to seal an iatrogenic fetal membrane defect. Fetal membrane homogenates potently induced thrombin generation in amniotic fluid and diluted plasma. Upon the addition of fibrinogen concentrate, potent fibrin formation was triggered. Measured by densiometry, fibrin formation was optimal at 1250 µg/mL fibrinogen in combination with 4% plasma. A collagen plug soaked with fibrinogen and plasma sealed an iatrogenic membrane defect about 35% better than collagen plugs without these additives (P = 0.037). These in vitro experiments suggest that the addition of fibrinogen and plasma may enhance the sealing efficacy of collagen plugs in closing iatrogenic fetal membrane defects. © 2013 John Wiley & Sons, Ltd.

  10. Bony change of apical lesion healing process using fractal analysis

    International Nuclear Information System (INIS)

    Lee, Ji Min; Park, Hyok; Jeong, Ho Gul; Kim, Kee Deog; Park, Chang Seo

    2005-01-01

    To investigate the change of bone healing process after endodontic treatment of the tooth with an apical lesion by fractal analysis. Radiographic images of 35 teeth from 33 patients taken on first diagnosis, 6 months, and 1 year after endodontic treatment were selected. Radiographic images were taken by JUPITER computerized Dental X-ray System. Fractal dimensions were calculated three times at each area by Scion Image PC program. Rectangular region of interest (30 x 30) were selected at apical lesion and normal apex of each image. The fractal dimension at apical lesion of first diagnosis (L 0 ) is 0.940 ± 0.361 and that of normal area (N 0 ) is 1.186 ± 0.727 (p 1 ) is 1.076 ± 0.069 and that of normal area (N 1 ) is 1.192 ± 0.055 (p 2 ) is 1.163 ± 0.074 and that of normal area (N 2 ) is 1.225 ± 0.079 (p<0.05). After endodontic treatment, the fractal dimensions at each apical lesions depending on time showed statistically significant difference. And there are statistically significant different between normal area and apical lesion on first diagnosis, 6 months after, 1 year after. But the differences were grow smaller as time flows. The evaluation of the prognosis after the endodontic treatment of the apical lesion was estimated by bone regeneration in apical region. Fractal analysis was attempted to overcome the limit of subjective reading, and as a result the change of the bone during the healing process was able to be detected objectively and quantitatively.

  11. Ossifying fibroma misdiagnosed as chronic apical periodontitis.

    Science.gov (United States)

    de Moraes Ramos-Perez, Flávia Maria; Soares, Ulysses Nicida; Silva-Sousa, Yara Teresinha Corrêa; da Cruz Perez, Danyel Elias

    2010-03-01

    Ossifying fibroma mimicking chronic apical periodontitis is extremely rare. This report describes a case of ossifying fibroma located in the periapical region of the mandibular right canine that was misdiagnosed as chronic apical periodontitis. A 40-year-old woman complained of slight pain in the right anterior mandibular region without mucosal abnormalities or swelling. Radiographically, a well-circumscribed, unilocular, radiolucent lesion was observed that was located in the periapical region of the mandibular right canine, which presented an endodontically treated root canal. Under local anesthesia, the lesion was fully excised. Microscopically, there was fibrocellular connective tissue associated with a mineralized component, which consisted of lamellar or trabecular and woven bone, compatible with the diagnosis of ossifying fibroma. Although it is very rare, ossifying fibroma should be considered in the differential diagnosis of unusual or persistent apical radiolucencies. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Seals Research at AlliedSignal

    Science.gov (United States)

    Ullah, M. Rifat

    1996-01-01

    A consortium has been formed to address seal problems in the Aerospace sector of Allied Signal, Inc. The consortium is represented by makers of Propulsion Engines, Auxiliary Power Units, Gas Turbine Starters, etc. The goal is to improve Face Seal reliability, since Face Seals have become reliability drivers in many of our product lines. Several research programs are being implemented simultaneously this year. They include: Face Seal Modeling and Analysis Methodology; Oil Cooling of Seals; Seal Tracking Dynamics; Coking Formation & Prevention; and Seal Reliability Methods.

  13. Brush seal performance measurement system

    OpenAIRE

    Aksoy, Serdar; Akşit, Mahmut Faruk; Aksit, Mahmut Faruk; Duran, Ertuğrul Tolga; Duran, Ertugrul Tolga

    2009-01-01

    Brush seals are rapidly replacing conventional labyrinth seals in turbomachinery applications. Upon pressure application, seal stiffness increases drastically due to frictional bristle interlocking. Operating stiffness is critical to determine seal wear life. Typically, seal stiffness is measured by pressing a curved shoe to brush bore. The static-unpressurized measurement is extrapolated to pressurized and high speed operating conditions. This work presents a seal stiffness measurement syste...

  14. Seals

    International Nuclear Information System (INIS)

    Welsher, R.A.G.

    1982-01-01

    An aperture through a biological shield is sealed by a flexible sheath having a beading at one end located on an annular member slidable in the aperture such that the beading bears in sealing engagement against the sides of the aperture. The annular member is retained by a retractable latch and can be rejected by pushing it out of the aperture using a replacement annular member with a replacement sheath thereon to butt against the annular member to be rejected. The replacement annular member may be mounted on a tubular device having an outer co-axial member for operating the latch when the replacement annular member butts against the annular member to be rejected. Applications include effecting a seal between a remote handling equipment and a wall through which the equipment extends. (author)

  15. Electronic seal

    International Nuclear Information System (INIS)

    Musyck, E.

    1981-01-01

    An electronic seal is presented for a volume such as container for fissile materials. The seal encloses a lock for barring the space as well as a device for the detection and the recording of the intervention of the lock. (AF)

  16. Monocyte chemotactic protein-3: possible involvement in apical periodontitis chemotaxis.

    Science.gov (United States)

    Dezerega, A; Osorio, C; Mardones, J; Mundi, V; Dutzan, N; Franco, M; Gamonal, J; Oyarzún, A; Overall, C M; Hernández, M

    2010-10-01

    To study the expression of monocyte chemotactic protein-3 (MCP-3, also known as chemokine CCL-7) in tissue from apical lesions (AL) and to associate MCP-3 expression with symptomatic or asymptomatic apical periodontitis. To determine the expression of MCP-3 in AL, biopsies obtained during tooth extraction procedures were fixed, subjected to routine processing and diagnosed as apical granuloma (AG) (n = 7) or radicular cyst (RC) (n = 5). As controls, apical periodontal ligament (PDL) specimens from healthy premolars extracted for orthodontics reasons were included (n = 7). All specimens were immunostained for MCP-3 and examined under a light microscope. In addition, homogenates from AL (n = 14) and healthy PDL samples (n = 7) were studied through immunowestern blot. Finally, periapical exudates samples were collected from root canals of teeth having diagnosis of symptomatic (n = 14) and asymptomatic apical periodontitis (n = 14) during routine endodontic treatments and analysed by immunowestern blot and densitometry.   MCP-3 was detected in AG and RC and localized mainly to inflammatory leucocytes, whereas no expression was observed in healthy PDLs. MCP-3 was also detected in periapical exudate, and its levels were significantly higher in symptomatic than in asymptomatic apical periodontitis. MCP-3 was expressed in AL and its levels associated with clinical symptoms. MCP-3 might play a role in disease pathogenesis, possibly by stimulating mononuclear chemotaxis. © 2010 International Endodontic Journal.

  17. Histology of periapical lesions obtained during apical surgery.

    Science.gov (United States)

    Schulz, Malte; von Arx, Thomas; Altermatt, Hans Jörg; Bosshardt, Dieter

    2009-05-01

    The aim of this was to evaluate the histology of periapical lesions in teeth treated with periapical surgery. After root-end resection, the root tip was removed together with the periapical pathological tissue. Histologic sectioning was performed on calcified specimens embedded in methylmethacrylate (MMA) and on demineralized specimens embedded in LR White (Fluka, Buchs, Switzerland). The samples were evaluated with light and transmission electron microscopy (TEM). The histologic findings were classified into periapical abscesses, granulomas, or cystic lesions (true or pocket cysts). The final material comprised 70% granulomas, 23% cysts and 5% abscesses, 1% scar tissues, and 1% keratocysts. Six of 125 samples could not be used. The cystic lesions could not be subdivided into pocket or true cysts. All cysts had an epithelium-lined cavity, two of them with cilia-lined epithelium. These results show the high incidence of periapical granulomas among periapical lesions obtained during apical surgery. Periapical abscesses were a rare occasion. The histologic findings from samples obtained during apical surgery may differ from findings obtained by teeth extractions. A determination between pocket and true apical cysts is hardly possible when collecting samples by apical surgery.

  18. Pro-oxidant status and matrix metalloproteinases in apical lesions and gingival crevicular fluid as potential biomarkers for asymptomatic apical periodontitis and endodontic treatment response

    Directory of Open Access Journals (Sweden)

    Dezerega Andrea

    2012-03-01

    Full Text Available Abstract Background Oxidative stress and matrix metalloproteinases -9 and -2 are involved in periodontal breakdown, whereas gingival crevicular fluid has been reported to reflect apical status. The aim of this study was to characterize oxidant balance and activity levels of MMP -2 and -9 in apical lesions and healthy periodontal ligament; and second, to determine whether potential changes in oxidant balance were reflected in gingival crevicular fluid from asymptomatic apical periodontitis (AAP-affected teeth at baseline and after endodontic treatment. Methods Patients with clinical diagnosis of AAP and healthy volunteers having indication of tooth extraction were recruited. Apical lesions and healthy periodontal ligaments, respectively, were homogenized or processed to obtain histological tissue sections. Matrix metalloproteinase -9 and -2 levels and/or activity were analyzed by Immunowestern blot, zymography and consecutive densitometric analysis, and their tissue localization was confirmed by immunohistochemistry. A second group of patients with AAP and indication of endodontic treatment was recruited. Gingival crevicular fluid was extracted from AAP-affected teeth at baseline, after endodontic treatment and healthy contralateral teeth. Total oxidant and antioxidant status were determined in homogenized tissue and GCF samples. Statistical analysis was performed using STATA v10 software with unpaired t test, Mann-Whitney test and Spearman's correlation. Results Activity of MMP-2 and MMP-9 along with oxidant status were higher in apical lesions (p Conclusions Apical lesions display an oxidant imbalance along with increased activity of matrix metalloproteinase-2 and -9 and might contribute to AAP progression. Oxidant imbalance can also be reflected in GCF from AAP-affected teeth and was restored to normal levels after conservative endodontic treatment. These mediators might be useful as potential biomarkers for chair-side complementary diagnostic

  19. Pro-oxidant status and matrix metalloproteinases in apical lesions and gingival crevicular fluid as potential biomarkers for asymptomatic apical periodontitis and endodontic treatment response.

    Science.gov (United States)

    Dezerega, Andrea; Madrid, Sonia; Mundi, Verónica; Valenzuela, María A; Garrido, Mauricio; Paredes, Rodolfo; García-Sesnich, Jocelyn; Ortega, Ana V; Gamonal, Jorge; Hernández, Marcela

    2012-03-21

    Oxidative stress and matrix metalloproteinases -9 and -2 are involved in periodontal breakdown, whereas gingival crevicular fluid has been reported to reflect apical status. The aim of this study was to characterize oxidant balance and activity levels of MMP -2 and -9 in apical lesions and healthy periodontal ligament; and second, to determine whether potential changes in oxidant balance were reflected in gingival crevicular fluid from asymptomatic apical periodontitis (AAP)-affected teeth at baseline and after endodontic treatment. Patients with clinical diagnosis of AAP and healthy volunteers having indication of tooth extraction were recruited. Apical lesions and healthy periodontal ligaments, respectively, were homogenized or processed to obtain histological tissue sections. Matrix metalloproteinase -9 and -2 levels and/or activity were analyzed by Immunowestern blot, zymography and consecutive densitometric analysis, and their tissue localization was confirmed by immunohistochemistry. A second group of patients with AAP and indication of endodontic treatment was recruited. Gingival crevicular fluid was extracted from AAP-affected teeth at baseline, after endodontic treatment and healthy contralateral teeth. Total oxidant and antioxidant status were determined in homogenized tissue and GCF samples. Statistical analysis was performed using STATA v10 software with unpaired t test, Mann-Whitney test and Spearman's correlation. Activity of MMP-2 and MMP-9 along with oxidant status were higher in apical lesions (p Apical lesions display an oxidant imbalance along with increased activity of matrix metalloproteinase-2 and -9 and might contribute to AAP progression. Oxidant imbalance can also be reflected in GCF from AAP-affected teeth and was restored to normal levels after conservative endodontic treatment. These mediators might be useful as potential biomarkers for chair-side complementary diagnostic of apical status in GCF.

  20. Prevalence of ciliated epithelium in apical periodontitis lesions.

    Science.gov (United States)

    Ricucci, Domenico; Loghin, Simona; Siqueira, José F; Abdelsayed, Rafik A

    2014-04-01

    This article reports on the morphologic features and the frequency of ciliated epithelium in apical cysts and discusses its origin. The study material consisted of 167 human apical periodontitis lesions obtained consecutively from patients presenting for treatment during a period of 12 years in a dental practice operated by one of the authors. All of the lesions were obtained still attached to the root apices of teeth with untreated (93 lesions) or treated canals (74 lesions). The former were obtained by extraction and the latter by extraction or apical surgery. Specimens were processed for histopathologic and histobacteriologic analyses. Lesions were classified, and the type of epithelium, if present, was recorded. Of the lesions analyzed, 49 (29%) were diagnosed as cysts. Of these, 26 (53%) were found in untreated teeth, and 23 (47%) related to root canal-treated teeth. Ciliated columnar epithelium was observed partially or completely lining the cyst wall in 4 cysts, and all of them occurred in untreated maxillary molars. Three of these lesions were categorized as pocket cysts, and the other was a true cyst. Ciliated columnar epithelium-lined cysts corresponded to approximately 2% of the apical periodontitis lesions and 8% of the cysts of endodontic origin in the population studied. This epithelium is highly likely to have a sinus origin in the majority of cases. However, the possibility of prosoplasia or upgraded differentiation into ciliated epithelium from the typical cystic lining squamous epithelium may also be considered. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. Apical extrusion of debris using reciprocating files and rotary ...

    African Journals Online (AJOL)

    Procedure: Sixty extracted human mandibular premolars were used. The root canals were instrumented using reciprocating (WaveOne, Reciproc, SafeSider) or rotary ... and cross‑sections, and kinematics, and this situation may influence the amount of apically extruded debris through the apical foramen.[15]. The aim of this ...

  2. Shaft seal assembly and method

    Science.gov (United States)

    Keba, John E. (Inventor)

    2007-01-01

    A pressure-actuated shaft seal assembly and associated method for controlling the flow of fluid adjacent a rotatable shaft are provided. The seal assembly includes one or more seal members that can be adjusted between open and closed positions, for example, according to the rotational speed of the shaft. For example, the seal member can be configured to be adjusted according to a radial pressure differential in a fluid that varies with the rotational speed of the shaft. In addition, in the closed position, each seal member can contact a rotatable member connected to the shaft to form a seal with the rotatable member and prevent fluid from flowing through the assembly. Thus, the seal can be closed at low speeds of operation and opened at high speeds of operation, thereby reducing the heat and wear in the seal assembly while maintaining a sufficient seal during all speeds of operation.

  3. Cone-beam computed tomography analysis of the apical third of curved roots after mechanical preparation with different automated systems

    International Nuclear Information System (INIS)

    Oliveira, Cesar Augusto Pereira; Pascoalato, Cristina; Meurer, Maria Ines; Silva, Silvio Rocha Correa

    2009-01-01

    The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a 40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used. (author)

  4. Cone-beam computed tomography analysis of the apical third of curved roots after mechanical preparation with different automated systems

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cesar Augusto Pereira; Pascoalato, Cristina [University of Southern Santa Catarina (UNISUL), Tubarao, SC (Brazil); Meurer, Maria Ines [Federal University of Santa Catarina (UFSC), Florianopolis, SC (Brazil); Silva, Silvio Rocha Correa, E-mail: silvio@foar.unesp.b [Sao Paulo State University (UNESP), Araraquara, SP (Brazil)

    2009-07-01

    The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a 40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 +- 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 +- 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used. (author)

  5. Incidental apical disease at CT scanning

    International Nuclear Information System (INIS)

    McLoud, T.C.; Satoh, K.; Shepard, J.O.; Moore, E.H.; Kosiuk, J.P.

    1990-01-01

    Apical caps are commonly noted on standard radiographs. This paper determines how often abnormalities in the extreme apex of the lung could be identified on CT scans obtained for other reasons. A total of 158 consecutive CT scans were reviewed prospectively. Excluded were patients with obvious upper lobe pleural or parenchymal disease. Apical abnormalities were identified in 74 (46.8%) of the 158 cases. The prevalence increased with age (19% in the 8-39-year age group and 82% in patients older than 80 years). Opacities were unilateral in 44.5% and bilateral in 55.5%. The most common abnormality was linear opacities (95%)

  6. Rotary shaft seal

    International Nuclear Information System (INIS)

    Langebrake, C.O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transducer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing

  7. Seal containment system

    International Nuclear Information System (INIS)

    Kugler, R.W.; Gerkey, K.S.; Kasner, W.H.

    1978-01-01

    An automated system for transporting nuclear fuel elements between fuel element assembly stations without contaminating the area outside the sealed assembly stations is described. The system comprises a plurality of assembly stations connected together by an elongated horizontal sealing mechanism and an automatic transport mechanism for transporting a nuclear fuel element in a horizontal attitude between the assembly stations while the open end of the fuel element extends through the sealing mechanism into the assembly station enclosure. The sealing mechanism allows the fuel element to be advanced by the transport mechanism while limiting the escape of radioactive particles from within the assembly station enclosure. 4 claims, 6 figures

  8. Frequency and levels of candidate endodontic pathogens in acute apical abscesses as compared to asymptomatic apical periodontitis

    Science.gov (United States)

    Rôças, Isabela N.

    2018-01-01

    Introduction Acute apical abscess is caused by bacteria that leave the infected dental root canal to invade the periodontal tissues. Most species occurring in abscesses are also found in asymptomatic infections; therefore, the possibility exists that not only the presence of certain species but also their specific counts influence the appearance of symptoms. This molecular study compared the frequency and levels of several candidate endodontic pathogens in teeth with acute apical abscesses and asymptomatic apical periodontitis. Methods Samples were taken from the root canals of teeth with asymptomatic apical periodontitis (n = 73) and by aspiration of purulent exudate from acute abscesses (n = 55). DNA was extracted from samples and bacterial identifications were performed by a closed-ended semi-quantitative reverse-capture checkerboard approach targeting 40 bacterial species/phylotypes. Results Bacterial DNA was detected in all cases. In abscesses, the most prevalent taxa were Fusobacterium nucleatum (60%), Porphyromonas endodontalis (53%), Parvimonas micra (51%), and Streptococcus species (45%). The most frequently detected taxa in asymptomatic teeth were P. endodontalis (63%), Dialister invisus (58%), Olsenella uli (56%), and F. nucleatum (51%). None of the targeted taxa were significantly associated with abscesses when only mere presence was evaluated (p>0.05). However, semi-quantitative data demonstrated that P. endodontalis, Prevotella baroniae, Treponema denticola and Streptococcus species were significantly more frequent at levels >105 in abscesses than in asymptomatic cases (pabscesses in terms of frequency. However, some taxa were significantly found in higher levels in abscesses. Presence of a potentially virulent pathogen in high counts may increase the collective pathogenicity of the bacterial community and give rise to symptoms. PMID:29293651

  9. Frequency and levels of candidate endodontic pathogens in acute apical abscesses as compared to asymptomatic apical periodontitis.

    Science.gov (United States)

    Rôças, Isabela N; Siqueira, José F

    2018-01-01

    Acute apical abscess is caused by bacteria that leave the infected dental root canal to invade the periodontal tissues. Most species occurring in abscesses are also found in asymptomatic infections; therefore, the possibility exists that not only the presence of certain species but also their specific counts influence the appearance of symptoms. This molecular study compared the frequency and levels of several candidate endodontic pathogens in teeth with acute apical abscesses and asymptomatic apical periodontitis. Samples were taken from the root canals of teeth with asymptomatic apical periodontitis (n = 73) and by aspiration of purulent exudate from acute abscesses (n = 55). DNA was extracted from samples and bacterial identifications were performed by a closed-ended semi-quantitative reverse-capture checkerboard approach targeting 40 bacterial species/phylotypes. Bacterial DNA was detected in all cases. In abscesses, the most prevalent taxa were Fusobacterium nucleatum (60%), Porphyromonas endodontalis (53%), Parvimonas micra (51%), and Streptococcus species (45%). The most frequently detected taxa in asymptomatic teeth were P. endodontalis (63%), Dialister invisus (58%), Olsenella uli (56%), and F. nucleatum (51%). None of the targeted taxa were significantly associated with abscesses when only mere presence was evaluated (p>0.05). However, semi-quantitative data demonstrated that P. endodontalis, Prevotella baroniae, Treponema denticola and Streptococcus species were significantly more frequent at levels >105 in abscesses than in asymptomatic cases (p<0.05). None of the target species/phylotypes were associated with abscesses in terms of frequency. However, some taxa were significantly found in higher levels in abscesses. Presence of a potentially virulent pathogen in high counts may increase the collective pathogenicity of the bacterial community and give rise to symptoms.

  10. Core disruptive accident margin seal

    International Nuclear Information System (INIS)

    Golden, M.P.

    1979-01-01

    An apparatus for sealing the annulus defined within a substantially cylindrical rotatable riser assembly and plug combination of a nuclear reactor closure head is described. The apparatus comprises an inflatable sealing mechanism disposed in one portion of the riser assembly near the annulus such that upon inflation the sealing mechanism is radially actuated against the other portion of the riser assembly thereby sealing the annulus. The apparatus further comprises a connecting mechanism which places one end of the sealing mechanism in fluid communication with the reactor cover gas so that overpressurization of the reactor cover gas will increase the radial actuation of the sealing mechanism thus enhancing sealing of the annulus

  11. Neuroelectric Tuning of Cortical Oscillations by Apical Dendrites in Loop Circuits

    Directory of Open Access Journals (Sweden)

    David LaBerge

    2017-06-01

    Full Text Available Bundles of relatively long apical dendrites dominate the neurons that make up the thickness of the cerebral cortex. It is proposed that a major function of the apical dendrite is to produce sustained oscillations at a specific frequency that can serve as a common timing unit for the processing of information in circuits connected to that apical dendrite. Many layer 5 and 6 pyramidal neurons are connected to thalamic neurons in loop circuits. A model of the apical dendrites of these pyramidal neurons has been used to simulate the electric activity of the apical dendrite. The results of that simulation demonstrated that subthreshold electric pulses in these apical dendrites can be tuned to specific frequencies and also can be fine-tuned to narrow bandwidths of less than one Hertz (1 Hz. Synchronous pulse outputs from the circuit loops containing apical dendrites can tune subthreshold membrane oscillations of neurons they contact. When the pulse outputs are finely tuned, they function as a local “clock,” which enables the contacted neurons to synchronously communicate with each other. Thus, a shared tuning frequency can select neurons for membership in a circuit. Unlike layer 6 apical dendrites, layer 5 apical dendrites can produce burst firing in many of their neurons, which increases the amplitude of signals in the neurons they contact. This difference in amplitude of signals serves as basis of selecting a sub-circuit for specialized processing (e.g., sustained attention within the typically larger layer 6-based circuit. After examining the sustaining of oscillations in loop circuits and the processing of spikes in network circuits, we propose that cortical functioning can be globally viewed as two systems: a loop system and a network system. The loop system oscillations influence the network system’s timing and amplitude of pulse signals, both of which can select circuits that are momentarily dominant in cortical activity.

  12. Improved circumferential shaft seal

    Science.gov (United States)

    Ludwig, L. P.; Strom, T. N.

    1974-01-01

    Comparative tests of modified and unmodified carbon ring seals showed that addition of helical grooves to conventional segmented carbon ring seals reduced leakage significantly. Modified seal was insensitive to shaft runout and to flooding by lubricant.

  13. Seals for sealing a pressure vessel such as a nuclear reactor vessel or the like

    International Nuclear Information System (INIS)

    Bruns, H.J.; Huelsermann, K.H.

    1975-01-01

    A description is given of seals for sealing a pressure vessel such as a nuclear reactor vessel, steam boiler vessel, or any other vessel which is desirably sealed against pressure of the type including a housing and a housing closure that present opposed vertical sealing surfaces which define the sides of a channel. The seals of the present invention comprise at least one sealing member disposed in the channel, having at least one stop face, a base portion and two shank portions extending from the base portion to form a groove-like recess. The shank portions are provided with sealing surfaces arranged to mate with the opposed vertical pressure vessel sealing surfaces. A shank-spreading wedge element also disposed in the channel has at least one stop face and is engaged in the groove-like recess with the sealing member and wedge element stop face adjacent to each other

  14. Emergence of fatal avian influenza in New England harbor seals

    Science.gov (United States)

    Anthony, S.J.; St. Leger, J. A.; Pugliares, K.; Ip, Hon S.; Chan, J.M.; Carpenter, Z.W.; Navarrete-Macias, I.; Sanchez-Leon, M.; Saliki, J.T.; Pedersen, J.; Karesh, W.; Daszak, P.; Rabadan, R.; Rowles, T.; Lipkin, W.I.

    2012-01-01

    From September to December 2011, 162 New England harbor seals died in an outbreak of pneumonia. Sequence analysis of postmortem samples revealed the presence of an avian H3N8 influenza A virus, similar to a virus circulating in North American waterfowl since at least 2002 but with mutations that indicate recent adaption to mammalian hosts. These include a D701N mutation in the viral PB2 protein, previously reported in highly pathogenic H5N1 avian influenza viruses infecting people. Lectin staining and agglutination assays indicated the presence of the avian-preferred SAα-2,3 and mammalian SAα-2,6 receptors in seal respiratory tract, and the ability of the virus to agglutinate erythrocytes bearing either the SAα-2,3 or the SAα-2,6 receptor. The emergence of this A/harbor seal/Massachusetts/1/2011 virus may herald the appearance of an H3N8 influenza clade with potential for persistence and cross-species transmission.

  15. Oral microbiota species in acute apical endodontic abscesses

    OpenAIRE

    Noelle George; Erin Flamiatos; Kellie Kawasaki; Namgu Kim; Charles Carriere; Brian Phan; Raphael Joseph; Shay Strauss; Richie Kohli; Dongseok Choi; J. Craig Baumgartner; Christine Sedgley; Tom Maier; Curtis A. Machida

    2016-01-01

    Background and objectives: Acute apical abscesses are serious endodontic diseases resulting from pulpal infection with opportunistic oral microorganisms. The objective of this study was to identify and compare the oral microbiota in patients (N=18) exhibiting acute apical abscesses, originating from the demographic region in Portland, Oregon. The study hypothesis is that abscesses obtained from this demographic region may contain unique microorganisms not identified in specimens from other re...

  16. Seals in nuclear reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The seals described are for use in a nuclear reactor where there are fuel assemblies in a vessel, an inlet and an outlet for circulating a coolant in heat transfer relationship with the fuel assemblies and a closure head on the vessel in a tight fluid relationship. The closure head comprises rotatable plugs which have mechanical seals disposed in the annulus around each plug while allowing free rotation of the plug when the seal is not actuated. The seal is usually an elastomer or copper. A means of actuating the seal is attached for drawing it vertically into the annulus for sealing. When the reactor coolant is liquid sodium, contact with oxygen must be avoided and argon cover gas fills the space between the bottom of the closure head and the coolant liquid level and the annuli in the closure head. (U.K.)

  17. Investigation of positive shaft seals

    Science.gov (United States)

    Pfouts, J. O.

    1970-01-01

    Welded metal bellows secondary seals prevent secondary seal leakage with a minimum number of potential leak paths. High performance seal is obtained by controlling the potentially unstable seal-face movements induced by mechanical vibrations and fluid pressure pulsations.

  18. Continuous improvement of pump seals

    International Nuclear Information System (INIS)

    Wong, W.; Eyvindson, A.; Rhodes, D.B.

    2003-01-01

    Pump seal reliability continues to be an area needing improvement and ongoing vigilance. Methods have been developed for identifying and assessing factors relating to seal performance, selecting the most relevant ones for a specific station, and then focusing on the most significant aspects and how to improve. Discussion invariably addresses maintenance practices, seal design, monitoring capabilities, operating conditions, transients, and pump and motor design. Success in reliability improvement requires ongoing dialogue among the station operators, pump manufacturers and seal designers. AECL CAN-seals lead the nuclear industry in reliability and seal life. They effectively save operators millions of dollars in outage time and person-rem. This paper describes some of the significant developments in AECL's ongoing program in seal R and D, as well as recent new installations following the most demanding seal qualification programs to date. (author)

  19. Environmental predictors of ice seal presence in the Bering Sea.

    Science.gov (United States)

    Miksis-Olds, Jennifer L; Madden, Laura E

    2014-01-01

    Ice seals overwintering in the Bering Sea are challenged with foraging, finding mates, and maintaining breathing holes in a dark and ice covered environment. Due to the difficulty of studying these species in their natural environment, very little is known about how the seals navigate under ice. Here we identify specific environmental parameters, including components of the ambient background sound, that are predictive of ice seal presence in the Bering Sea. Multi-year mooring deployments provided synoptic time series of acoustic and oceanographic parameters from which environmental parameters predictive of species presence were identified through a series of mixed models. Ice cover and 10 kHz sound level were significant predictors of seal presence, with 40 kHz sound and prey presence (combined with ice cover) as potential predictors as well. Ice seal presence showed a strong positive correlation with ice cover and a negative association with 10 kHz environmental sound. On average, there was a 20-30 dB difference between sound levels during solid ice conditions compared to open water or melting conditions, providing a salient acoustic gradient between open water and solid ice conditions by which ice seals could orient. By constantly assessing the acoustic environment associated with the seasonal ice movement in the Bering Sea, it is possible that ice seals could utilize aspects of the soundscape to gauge their safe distance to open water or the ice edge by orienting in the direction of higher sound levels indicative of open water, especially in the frequency range above 1 kHz. In rapidly changing Arctic and sub-Arctic environments, the seasonal ice conditions and soundscapes are likely to change which may impact the ability of animals using ice presence and cues to successfully function during the winter breeding season.

  20. Environmental predictors of ice seal presence in the Bering Sea.

    Directory of Open Access Journals (Sweden)

    Jennifer L Miksis-Olds

    Full Text Available Ice seals overwintering in the Bering Sea are challenged with foraging, finding mates, and maintaining breathing holes in a dark and ice covered environment. Due to the difficulty of studying these species in their natural environment, very little is known about how the seals navigate under ice. Here we identify specific environmental parameters, including components of the ambient background sound, that are predictive of ice seal presence in the Bering Sea. Multi-year mooring deployments provided synoptic time series of acoustic and oceanographic parameters from which environmental parameters predictive of species presence were identified through a series of mixed models. Ice cover and 10 kHz sound level were significant predictors of seal presence, with 40 kHz sound and prey presence (combined with ice cover as potential predictors as well. Ice seal presence showed a strong positive correlation with ice cover and a negative association with 10 kHz environmental sound. On average, there was a 20-30 dB difference between sound levels during solid ice conditions compared to open water or melting conditions, providing a salient acoustic gradient between open water and solid ice conditions by which ice seals could orient. By constantly assessing the acoustic environment associated with the seasonal ice movement in the Bering Sea, it is possible that ice seals could utilize aspects of the soundscape to gauge their safe distance to open water or the ice edge by orienting in the direction of higher sound levels indicative of open water, especially in the frequency range above 1 kHz. In rapidly changing Arctic and sub-Arctic environments, the seasonal ice conditions and soundscapes are likely to change which may impact the ability of animals using ice presence and cues to successfully function during the winter breeding season.

  1. Macrophage polarization differs between apical granulomas, radicular cysts, and dentigerous cysts.

    Science.gov (United States)

    Weber, Manuel; Schlittenbauer, Tilo; Moebius, Patrick; Büttner-Herold, Maike; Ries, Jutta; Preidl, Raimund; Geppert, Carol-Immanuel; Neukam, Friedrich W; Wehrhan, Falk

    2018-01-01

    Apical periodontitis can appear clinically as apical granulomas or radicular cysts. There is evidence that immunologic factors are involved in the pathogenesis of both pathologies. In contrast to radicular cysts, the dentigerous cysts have a developmental origin. Macrophage polarization (M1 vs M2) is a main regulator of tissue homeostasis and differentiation. There are no studies comparing macrophage polarization in apical granulomas, radicular cysts, and dentigerous cysts. Forty-one apical granulomas, 23 radicular cysts, and 23 dentigerous cysts were analyzed in this study. A tissue microarray (TMA) of the 87 consecutive specimens was created, and CD68-, CD11c-, CD163-, and MRC1-positive macrophages were detected by immunohistochemical methods. TMAs were digitized, and the expression of macrophage markers was quantitatively assessed. Radicular cysts are characterized by M1 polarization of macrophages while apical granulomas show a significantly higher degree of M2 polarization. Dentigerous cysts have a significantly lower M1 polarization than both analyzed periapical lesions (apical granulomas and radicular cysts) and accordingly, a significantly higher M2 polarization than radicular cysts. Macrophage cell density in dentigerous cysts is significantly lower than in the periapical lesions. The development of apical periodontitis towards apical granulomas or radicular cysts might be directed by macrophage polarization. Radicular cyst formation is associated with an increased M1 polarization of infiltrating macrophages. In contrast to radicular cysts, dentigerous cysts are characterized by a low macrophage infiltration and a high degree of M2 polarization, possibly reflecting their developmental rather than inflammatory origin. As M1 polarization of macrophages is triggered by bacterial antigens, these results underline the need for sufficient bacterial clearance during endodontic treatment to prevent a possible M1 macrophage-derived stimulus for radicular cyst

  2. Ferrules seals

    Science.gov (United States)

    Smith, J.L.

    1984-07-10

    A device is provided for sealing an inner tube and an outer tube without excessively deforming the tubes. The device includes two ferrules which cooperate to form a vacuum-tight seal between the inner tube and outer tube and having mating surfaces such that overtightening is not possible. 3 figs.

  3. A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid.

    Science.gov (United States)

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    2011-03-01

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.

  4. Borehole sealing method and apparatus

    International Nuclear Information System (INIS)

    Hartley, J.N.; Jansen, G. Jr.

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole. 5 claims, 1 figure

  5. The fast-recycling receptor Megalin defines the apical recycling pathway of epithelial cells

    Science.gov (United States)

    Perez Bay, Andres E.; Schreiner, Ryan; Benedicto, Ignacio; Paz Marzolo, Maria; Banfelder, Jason; Weinstein, Alan M.; Rodriguez-Boulan, Enrique J.

    2016-01-01

    The basolateral recycling and transcytotic pathways of epithelial cells were previously defined using markers such as transferrin (TfR) and polymeric IgA (pIgR) receptors. In contrast, our knowledge of the apical recycling pathway remains fragmentary. Here we utilize quantitative live-imaging and mathematical modelling to outline the recycling pathway of Megalin (LRP-2), an apical receptor with key developmental and renal functions, in MDCK cells. We show that, like TfR, Megalin is a long-lived and fast-recycling receptor. Megalin enters polarized MDCK cells through segregated apical sorting endosomes and subsequently intersects the TfR and pIgR pathways at a perinuclear Rab11-negative compartment termed common recycling endosomes (CRE). Whereas TfR recycles to the basolateral membrane from CRE, Megalin, like pIgR, traffics to subapical Rab11-positive apical recycling endosomes (ARE) and reaches the apical membrane in a microtubule- and Rab11-dependent manner. Hence, Megalin defines the apical recycling pathway of epithelia, with CRE as its apical sorting station. PMID:27180806

  6. Adhesive sealing of dentin surfaces in vitro: A review

    Science.gov (United States)

    Abu-Nawareg, Manar M; Zidan, Ahmed Z; Zhou, Jianfeng; Agee, Kelli; Chiba, Ayaka; Tagami, Jungi; Pashley, David H

    2016-01-01

    Purpose The purpose of this review is to describe the evolution of the use of dental adhesives to form a tight seal of freshly prepared dentin to protect the pulp from bacterial products, during the time between crown preparation and final cementum of full crowns. The evolution of these “immediate dentin sealants” follows the evolution of dental adhesives, in general. That is, they began with multiple-step, etch-and-rinse adhesives, and then switched to the use of simplified adhesives. Methods Literature was reviewed for evidence that bacteria or bacterial products diffusing across dentin can irritate pulpal tissues before and after smear layer removal. Smear layers can be solubilized by plaque organisms within 7–10 days if they are directly exposed to oral fluids. It is likely that smear layers covered by temporary restorations may last more than one month. As long as smear layers remain in place, they can partially seal dentin. Thus, many in vitro studies evaluating the sealing ability of adhesive resins use smear layer-covered dentin as a reference condition. Surprisingly, many adhesives do not seal dentin as well as do smear layers. Results Both in vitro and in vivo studies show that resin-covered dentin allows dentinal fluid to cross polymerized resins. The use of simplified single bottle adhesives to seal dentin was a step backwards. Currently, most authorities use either 3-step adhesives such as Scotchbond Multi-Purposea or OptiBond FLb or two-step self-etching primer adhesives, such as Clearfil SEc, Unifil Bondd or AdheSEe, respectfully. PMID:26846037

  7. Apical Hypertrophic Cardiomyopathy in Association with PulmonaryArtery Hypertension

    Directory of Open Access Journals (Sweden)

    Mehdi Peighambari

    2012-09-01

    Full Text Available Apical Hypertrophic Cardiomyopathy is an uncommon condition constituting 1% -2% of the cases with Hypertrophic Cardiomyopathy (HCM diagnosis. We interestingly report two patients with apical hypertrophic cardiomyopathy in association with significant pulmonary artery hypertension without any other underlying reason for pulmonary hypertension. The patients were assessed by echocardiography, cardiac catheterization and pulmonary function parameters study.

  8. TECHNOLOGY ROADMAPPING FOR IAEA SEALS.

    Energy Technology Data Exchange (ETDEWEB)

    HOFFHEINS,B.; ANNESE,C.; GOODMAN,M.; OCONNOR,W.; GUSHUE,S.; PEPPER,S.

    2003-07-13

    In the fall of 2002, the U.S. Support Program (USSP) initiated an effort to define a strategy or ''roadmap'' for future seals technologies and to develop a generalized process for planning safeguards equipment development, which includes seals and other safeguards equipment. The underlying objectives of the USSP include becoming more proactive than reactive in addressing safeguards equipment needs, helping the IAEA to maintain an inventory of cost-effective, reliable, and effective safeguards equipment, establishing a long-term planning horizon, and securing IAEA ownership in the process of effective requirements definition and timely transitioning of new or improved systems for IAEA use. At an initial workshop, seals, their functions, performance issues, and future embodiments were discussed in the following order: adhesive seals, metal seals, passive and active loop seals, ultrasonic seals, tamper indicating enclosures (including sample containers, equipment enclosures, and conduits). Suggested improvements to these technologies focused largely on a few themes: (1) The seals must be applied quickly, easily, and correctly; (2) Seals and their associated equipment should not unduly add bulk or weight to the inspectors load; (3) Rapid, in-situ verifiability of seals is desirable; and (4) Seal systems for high risk or high value applications should have two-way, remote communications. Based upon these observations and other insights, the participants constructed a skeletal approach for seals technology planning. The process begins with a top-level review of the fundamental safeguards requirements and extraction of required system features, which is followed by analysis of suitable technologies and identification of technology gaps, and finally by development of a planning schedule for system improvements and new technology integration. Development of a comprehensive procedure will require the partnership and participation of the IAEA. The

  9. Closure and Sealing Design Calculation

    International Nuclear Information System (INIS)

    T. Lahnalampi; J. Case

    2005-01-01

    The purpose of the ''Closure and Sealing Design Calculation'' is to illustrate closure and sealing methods for sealing shafts, ramps, and identify boreholes that require sealing in order to limit the potential of water infiltration. In addition, this calculation will provide a description of the magma that can reduce the consequences of an igneous event intersecting the repository. This calculation will also include a listing of the project requirements related to closure and sealing. The scope of this calculation is to: summarize applicable project requirements and codes relating to backfilling nonemplacement openings, removal of uncommitted materials from the subsurface, installation of drip shields, and erecting monuments; compile an inventory of boreholes that are found in the area of the subsurface repository; describe the magma bulkhead feature and location; and include figures for the proposed shaft and ramp seals. The objective of this calculation is to: categorize the boreholes for sealing by depth and proximity to the subsurface repository; develop drawing figures which show the location and geometry for the magma bulkhead; include the shaft seal figures and a proposed construction sequence; and include the ramp seal figure and a proposed construction sequence. The intent of this closure and sealing calculation is to support the License Application by providing a description of the closure and sealing methods for the Safety Analysis Report. The closure and sealing calculation will also provide input for Post Closure Activities by describing the location of the magma bulkhead. This calculation is limited to describing the final configuration of the sealing and backfill systems for the underground area. The methods and procedures used to place the backfill and remove uncommitted materials (such as concrete) from the repository and detailed design of the magma bulkhead will be the subject of separate analyses or calculations. Post-closure monitoring will not

  10. Sealing of rock fractures

    International Nuclear Information System (INIS)

    Pusch, R.; Erlstroem, M.; Boergesson, L.

    1985-12-01

    The major water-bearing fractures in granite usually from fairly regular sets but the extension and degree of connectivity is varying. This means that only a few fractures that are interconnected with the deposition holes and larger water-bearing structures in a HLW repository are expected and if they can be identified and cut off through sealing it would be possible to improve the isolation of waste packages very effectively. Nature's own fracture sealing mechanisms may be simulated and a survey of the involved processes actually suggests a number of possible filling methods and substances. Most of them require high temperature and pressure and correspondingly sophisticated techniques, but some are of potential interest for immediate application with rather moderate effort. Such a technique is to fill the fractures with clayey substances which stay flexible and low-permeable provided that they remain physically and chemically intact. It is demonstrated in the report that effective grouting requires a very low viscosity and shear strength of the substance and this can be achieved by mechanical agitation as demonstrated in this report. Thus, by superimposing static pressure and shear waves induced by percussion hammering at a suitable frequency, clays and fine-grained silts as well as cement can be driven into fractures with an average aperture as small as 0.1 mm. Experiments were made in the laboratory using concrete and steel plates, and a field pilot test was also conducted under realistic conditions on site in Stripa. They all demonstrated the practicality of the 'dynamic injection technique' and that the fluid condition of the grouts yielded complete filling of the injected space to a considerable distance from the injection point. The field test indicated a good sealing ability as well as a surprisingly high resistance to erosion and piping. (author)

  11. Sealing properties of mechanical seals for an axial flow blood pump.

    Science.gov (United States)

    Tomioka, J; Mori, T; Yamazaki, K; Koyanagi, H

    1999-08-01

    A miniature intraventricular axial flow blood pump for left ventricular support is under development. One of the key technologies required for such pumps is sealing of the motor shaft. In this study, to prevent blood backflow into the motor side, mechanical seals were developed and their sealing properties investigated. In the experimental apparatus, the mechanical seal separated the bovine blood on the chamber side from the cooling water on the motor side. A leakage of the blood was measured by inductively coupled plasma (ICP) light emission analysis. The rate of hemolysis was measured by the cyanmethemoglobin method. Frictional torque acting on the shaft was measured by a torque transducer. In the experiments, the rotational speed of the shaft was changed from 1,000 to 10,000 rpm, and the contact force of the seal faces was changed from 1.96 to 4.31 N. To estimate lubrication regimes, the Stribeck curve, a diagram of the coefficient of friction against the bearing characteristic G number, was drawn. The results of the experiments showed that both the leakage of blood and the rate of hemolysis were very small. The friction loss was also very small. The mechanical seal was operated in various lubrication regimes, from a fluid lubrication regime to a mixed lubrication regime.

  12. Sealing ability and bond strength of four contemporary adhesives to enamel and to dentine.

    Science.gov (United States)

    Atash, R; Vanden Abbeele, A

    2005-12-01

    To compare the shear bond strength and microleakage of four adhesive systems to the enamel and dentine of primary bovine teeth. 120 bovine primary mandibular incisors were collected and stored in an aqueous 1% chloramine solution at room temperature for no longer than 3 months after extraction (80 for shear bond testing and 40 for microleakage evaluation). The adhesives tested were Clearfil SE bond (SE), Adper Prompt L Pop (LP), Xeno III (XE), and Prime and Bond NT (PB). For shear bond strength testing the specimens were wet ground to 600 grit SiC paper to expose a flat enamel or dentine surface. After bonding and restoration with Dyract AP (DAP), the teeth were subjected to shear stress using a universal testing machine. For microleakage evaluation, facial class V cavities were prepared half in enamel and half in cementum. All cavities were restored with DAP. After thermocycling and immersion in 2% methylene blue, the dye penetration was evaluated under a stereomicroscope. All data were analysed by Chi-square tests or Fisher's tests when adapted in order to determine the significant differences between groups. Results were considered as significant for p enamel 11.06 to 5.34, in decreasing order SE, LP, XE and PB and on dentine 10.47 to 4.74, in decreasing order SE, XE, LP and PB. Differences in bond strengths between the four systems on enamel and dentine were all statistically significant, excepted for XE vs LP (shear bond at dentine). No significant differences were recorded in the microleakage degree between the four adhesive systems on enamel and on dentine (p > 0.0.5). The highest shear bond strength was achieved by Clearfil SE bond and the lowest by Prime and Bond NT. There was no significant difference concerning the sealing ability of the four adhesive systems.

  13. Investigating the sealing capacity of a seal system in rock salt (DOPAS project)

    Energy Technology Data Exchange (ETDEWEB)

    Jantschik, Kyra; Moog, Helge C.; Czaikowski, Oliver; Wieczorek, Klaus [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Braunschweig (Germany)

    2016-11-15

    This paper describes research and development work on plugging and sealing repositories, an issue of fundamental importance for the rock salt option which represents one of the three European repository options, besides the clay rock and the crystalline rock options. The programme aims at providing experimental data needed for the theoretical analysis of the long-term sealing capacity of concrete- based sealing materials. In order to demonstrate hydro-mechanical material stability under representative load scenarios, a comprehensive laboratory testing programme is carried out. This comprises investigation of the sealing capacity of the combined seal system and impact of the so-called excavation-damaged zones (EDZ) as well as investigation of the hydro-chemical long-term stability of the seal in contact with different brines under diffusive and advective conditions. This paper presents experimental approaches and preliminary results from laboratory investigations on salt concrete and combined systems as obtained to date.

  14. Regenerator cross arm seal assembly

    Science.gov (United States)

    Jackman, Anthony V.

    1988-01-01

    A seal assembly for disposition between a cross arm on a gas turbine engine block and a regenerator disc, the seal assembly including a platform coextensive with the cross arm, a seal and wear layer sealingly and slidingly engaging the regenerator disc, a porous and compliant support layer between the platform and the seal and wear layer porous enough to permit flow of cooling air therethrough and compliant to accommodate relative thermal growth and distortion, a dike between the seal and wear layer and the platform for preventing cross flow through the support layer between engine exhaust and pressurized air passages, and air diversion passages for directing unregenerated pressurized air through the support layer to cool the seal and wear layer and then back into the flow of regenerated pressurized air.

  15. Aerial surveys of seals at Rødsand seal sanctuary and adjacent haul-out sites

    DEFF Research Database (Denmark)

    Teilmann, J.; Dietz, R.; Edren, Susi M.C.

    This report describes the preliminary results of aerial surveys at Rødsand seal sanctuary, southeast Denmark and adjacent seal haul-out sites in southwestern Baltic. The work was carried out in connection with studies of potential effects of the Nysted offshore wind farm. Rødsand seal sanctuary...... is a part of seal management area 4, and the area is believed to hold a more or less closed population with little exchange to other areas. Although the harbour seal is relatively stationary there may be movements between the haul-out sites in the area. A possible reaction to disturbance from...... the construction and operation of the wind farm may be that the seals use other haul-out sites to a higher extend....

  16. Soil seal development under simulated rainfall: Structural, physical and hydrological dynamics

    Science.gov (United States)

    Armenise, Elena; Simmons, Robert W.; Ahn, Sujung; Garbout, Amin; Doerr, Stefan H.; Mooney, Sacha J.; Sturrock, Craig J.; Ritz, Karl

    2018-01-01

    contrasting behaviour was related to different dynamics and processes of seal formation which depended on the soil properties. The impact of rainfall-induced surface sealing on the hydrological behaviour of soil (as represented by WDTP and Kun) was rapid and substantial: an average 60% reduction in Kun occurred for all soils between 2 and 9 min rainfall, and water repellent surfaces were identified for SZL and ZCL. This highlights that the condition of the immediate surface of agricultural soils involving rainfall-induced structural seals has a strong impact in the overall ability of soil to function as water reservoir.

  17. Ceramic/metal seals. [refractory materials for hermetic seals for lighium-metal sulfide batteries

    Science.gov (United States)

    Bredbenner, A. M.

    1977-01-01

    Design criteria are discussed for a hermetic seal capable of withstanding the 450 C operating temperature of a lithium-metal sulfide battery system. A mechanical seal consisting of two high strength alloy metal sleeves welded or brazed to a conductor assembly and pressed onto a ceramic is described. The conductor center passes through the ceramic but is not sealed to it. The seal is effected on the outside of the taper where the tubular part is pressed down over and makes contact.

  18. Oxygen minimum zone: An important oceanographic habitat for deep-diving northern elephant seals, Mirounga angustirostris.

    Science.gov (United States)

    Naito, Yasuhiko; Costa, Daniel P; Adachi, Taiki; Robinson, Patrick W; Peterson, Sarah H; Mitani, Yoko; Takahashi, Akinori

    2017-08-01

    Little is known about the foraging behavior of top predators in the deep mesopelagic ocean. Elephant seals dive to the deep biota-poor oxygen minimum zone (OMZ) (>800 m depth) despite high diving costs in terms of energy and time, but how they successfully forage in the OMZ remains largely unknown. Assessment of their feeding rate is the key to understanding their foraging behavior, but this has been challenging. Here, we assessed the feeding rate of 14 female northern elephant seals determined by jaw motion events (JME) and dive cycle time to examine how feeding rates varied with dive depth, particularly in the OMZ. We also obtained video footage from seal-mounted videos to understand their feeding in the OMZ. While the diel vertical migration pattern was apparent for most depths of the JME, some very deep dives, beyond the normal diel depth ranges, occurred episodically during daylight hours. The midmesopelagic zone was the main foraging zone for all seals. Larger seals tended to show smaller numbers of JME and lower feeding rates than smaller seals during migration, suggesting that larger seals tended to feed on larger prey to satisfy their metabolic needs. Larger seals also dived frequently to the deep OMZ, possibly because of a greater diving ability than smaller seals, suggesting their dependency on food in the deeper depth zones. Video observations showed that seals encountered the rarely reported ragfish ( Icosteus aenigmaticus ) in the depths of the OMZ, which failed to show an escape response from the seals, suggesting that low oxygen concentrations might reduce prey mobility. Less mobile prey in OMZ would enhance the efficiency of foraging in this zone, especially for large seals that can dive deeper and longer. We suggest that the OMZ plays an important role in structuring the mesopelagic ecosystem and for the survival and evolution of elephant seals.

  19. Nuclear instrumentation cable end seal

    International Nuclear Information System (INIS)

    Cannon, C.P.; Brown, D.P.

    1979-01-01

    An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions is described. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates

  20. Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis.

    Science.gov (United States)

    Western, J Sylvia; Dicksit, Daniel Devaprakash

    2017-01-01

    All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), and self-adjusting file (SAF; vibratory) endodontic instrumentation systems and to determine methods which produced lesser extrusion of debris apically. An extensive electronic database search was done in PubMed, Scopus, Cochrane, LILACS, and Google Scholar from inception until February 2016 using the key terms "Apical Debris Extrusion, extruded material, and manual/rotary/reciprocating/SAF systems." A systematic search strategy was followed to extract 12 potential articles from a total of 1352 articles. The overall effect size was calculated from the raw mean difference of weight of apically extruded debris. Statistically significant difference was seen in the following comparisons: SAF ProTaper. Apical extrusion of debris was invariably present in all the instrumentation systems analyzed. SAF system seemed to be periapical tissue friendly as it caused reduced apical extrusion compared to Rotary ProTaper and Wave One.

  1. Turbine interstage seal with self-balancing capability

    Science.gov (United States)

    Mills, Jacob A; Jones, Russell B; Sexton, Thomas D

    2017-09-26

    An interstage seal for a turbine of a gas turbine engine, the interstage seal having a seal carrier with an axial extending seal tooth movable with a stator of the engine, and a rotor with a seal surface that forms the interstage seal with the seal tooth, where a magnetic force produced by two magnets and a gas force produced by a gas pressure acting on the seal carrier forms a balancing force to maintain a close clearance of the seal without the seal tooth contacting the rotor seal surfaces during engine operation. In other embodiments, two pairs of magnets produce first and second magnetic forces that balance the seal in the engine.

  2. Research on RCP400-TB50 type reactor coolant pump shaft seal failure analysis and monitoring method

    International Nuclear Information System (INIS)

    Yuan Chaolian; Shen Yuxian; Wang Chuan; Du Pengcheng

    2014-01-01

    Mechanical seal is widely applied in mechanical devices of nuclear power plant. 3-stages mechanical seal applied in reactor coolant pump (abbreviate to RCP) is a kind of product with top technology and manufacture difficulty. As the only running machine in primary loop of nuclear power plant, RCP is designed with high security, reliability and perform ability. So performance of its key component, 3-stages mechanical seal, could directly decide whether units can operate safely and reliably. In this paper mechanical seal used in RCP400-TB50 type RCP which in designed and manufactured by Andritz AG is selected as a typical example of dynamic pressure type mechanical seal applied in second generation NPP. Its structure and working principle is expounded. Engineering fluid mechanics theory is used to establish the mathematical model using for analyzing status of mechanical seal and deducing the theoretical formula. Its correctness is verified by compare with the test data. So that research result can be used as the theoretical basis for analysis of RCP400-TB50 RCP shaft seal's working condition. According to the shaft seal operation characteristic we can establish a suitable RCP shaft seal monitoring method and interlock protection setting for NPP operation. (authors)

  3. Enhanced sealing project (ESP): evolution of a full-sized concrete and bentonite shaft seal

    International Nuclear Information System (INIS)

    Dixon, D.A.; Priyanto, D.G.; Martino, J.B.; De Combarieu, M.; Johansson, R.; Korkeakoski, P.; Villagran, J.

    2012-01-01

    Document available in extended abstract form only. A full-scale shaft seal was designed and installed in the 5-m-diameter access shaft at Atomic Energy of Canada's (AECL's) Underground Research Laboratory (URL) at the point where he shaft intersects an ancient water-bearing, low-angle thrust fault in granitic rock. The seal, part of the permanent closure of the URL, consists of a 6-m-thick bentonite-based component sandwiched between 3-m-thick upper and lower, 3-m-thick concrete components. The bentonite-based component spans the fracture zone and extends approximately 1 m beyond the maximum identified extent of the fracture. This design was adopted in order to limit water from the deeper, saline regions mixing with the fresher, near-surface groundwater regime. The concrete components provide the mechanical confinement and an in situ compacted 40/60 mixture of bentonite clay and quartz sand provides the sealing component. Construction of the shaft seal was done as part of Canada's Nuclear Legacies Liability Program. However, monitoring the seal evolution was not part of the decommissioning program's mandate. In addition to accomplishing the permanent closure of the URL, this seal's construction provides a unique opportunity to instrument and monitor the evolution of a full-scale shaft seal as well as the recovery of the regional groundwater regime as the facility passively floods above the seal. A jointly funded monitoring project was developed by NWMO (Canada), SKB (Sweden), Posiva (Finland) and ANDRA (France) and since mid 2009 the thermal, hydraulic and mechanical evolution of the seal has been constantly monitored. The evolution of the type of seal being monitored in the ESP is of relevance to repository closure planning, gaining confidence in the functionality of shaft seals. Although constructed in a crystalline rock medium, the results of the ESP are expected to be relevant to the performance of seals in a variety of host rock types. The shaft seal has been

  4. Sealing a conduit end

    International Nuclear Information System (INIS)

    Mentz, R.M.

    1993-01-01

    An apparatus for sealing or blocking conduits, such as the primary nozzles of a nuclear steam generator is described. It includes an annular bracket sealingly attached to the open end of the nozzle, the bracket having a plurality of threaded holes therein. Mounted atop the bracket is a generally circular nozzle dam for covering the opening. Interposed between the nozzle dam and the bracket is an extrusion-resistant seal member having a plurality of apertures therethrough for receiving each bolt. The seal member is configured to resist extrusion by having laminated layers of differing hardnesses, so that the seal member will not laterally extrude away from each bolt in a manner that enlarges the aperture surrounding each bolt as the nozzle dam is bolted to the bracket. (author)

  5. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  6. Reusable, tamper-indicating seal

    International Nuclear Information System (INIS)

    Ryan, M.J.

    1978-01-01

    A reusable, tamper-indicating seal is comprised of a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body, visible from outside the seal, adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same postion. A new pattern of colored balls will appear in the segregated location when the seal is relocked

  7. Five-year longitudinal assessment of the prognosis of apical microsurgery.

    Science.gov (United States)

    von Arx, Thomas; Jensen, Simon S; Hänni, Stefan; Friedman, Shimon

    2012-05-01

    Apical surgery is an important treatment option for teeth with post-treatment apical periodontitis. Knowledge of the long-term prognosis is necessary when weighing apical surgery against alternative treatments. This study assessed the 5-year outcome of apical surgery and its predictors in a cohort for which the 1-year outcome was previously reported. Apical microsurgery procedures were uniformly performed using SuperEBA (Staident International, Staines, UK) or mineral trioxide aggregate (MTA) (ProRoot MTA; Dentsply Tulsa Dental Specialties, Tulsa, OK) root-end fillings or alternatively Retroplast capping (Retroplast Trading, Rorvig, Denmark). Subjects examined at 1 year (n = 191) were invited for the 5-year clinical and radiographic examination. Based on blinded, independent assessment by 3 calibrated examiners, the dichotomous outcome (healed or nonhealed) was determined and associated with patient-, tooth-, and treatment-related variables using logistic regression. At the 5-year follow-up, 9 of 191 teeth were unavailable, 12 of 191 teeth were extracted, and 170 of 191 teeth were examined (87.6% recall rate). A total of 129 of 170 teeth were healed (75.9%) compared with 83.8% at 1 year, and 85.3% were asymptomatic. Two significant outcome predictors were identified: the mesial-distal bone level at ≤ 3 mm versus >3 mm from the cementoenamel junction (78.2% vs 52.9% healed, respectively; odds ratio = 5.10; confidence interval, 1.67-16.21; P apical microsurgery was 8% poorer than assessed at 1 year. It also suggested that the prognosis was significantly impacted by the interproximal bone levels at the treated tooth and by the type of root-end filling material used. Copyright © 2012 American Association of Endodontists. All rights reserved.

  8. Immediate Implant Placement in Sockets with Asymptomatic Apical Periodontitis.

    Science.gov (United States)

    Crespi, Roberto; Capparé, Paolo; Crespi, Giovanni; Lo Giudice, Giuseppe; Gastaldi, Giorgio; Gherlone, Enrico

    2017-02-01

    The purpose of the present study was to evaluate if the presence of granulation tissue in asymptomatic apical periodontitis compromised immediate implant placement. Patients requiring extraction of one tooth (maxillary and mandibular incisive, canine or premolar) with asymptomatic apical periodontitis, were recruited for this prospective study. They were randomly scheduled into two groups: in first group (A) including 30 teeth, reactive soft tissue was debrided before implant placement, and in second group (B) including 30 teeth, reactive soft tissue was left in the apical lesion. Implants were positioned immediately after tooth extraction, and were loaded after 3 months in both groups. Cone beam computed tomography was performed before tooth extraction and at 1-year follow-up to evaluate the radiolucency around the root apex and the implant, bucco-lingual bone levels were also checked. Sixty patients were included in this study. Sixty implants were placed immediately after tooth extraction and, at 1-year follow-up, a survival rate of 100% was reported. After one year both groups showed absence of radiolucent zone at the apical region of implants. All fresh sockets presented a buccal-palatal bone reduction in both groups after one year, even if not statistically significant differences were found between baseline bone levels and within groups. Within the limitations of the present study, the immediate placement of implants into the extraction sockets with asymptomatic apical periodontitis, in presence of primary stability, did not lead to an increased rate of complications and rendered an equally favorable type of tissue integration. © 2016 Wiley Periodicals, Inc.

  9. Double angle seal forming lubricant film

    Science.gov (United States)

    Ernst, William D.

    1984-01-01

    A lubricated piston rod seal which inhibits gas leaking from a high pressure chamber on one side of the seal to a low pressure chamber on the other side of the seal. A liquid is supplied to the surface of the piston rod on the low pressure side of the seal. This liquid acts as lubricant for the seal and provides cooling for the rod. The seal, which can be a plastic, elastomer or other material with low elastic modulus, is designed to positively pump lubricant through the piston rod/seal interface in both directions when the piston rod is reciprocating. The capacity of the seal to pump lubricant from the low pressure side to the high pressure side is less than its capacity to pump lubricant from the high pressure side to the low pressure side which ensures that there is zero net flow of lubricant to the high pressure side of the seal. The film of lubricant between the seal and the rod minimizes any sliding contact and prevents the leakage of gas. Under static conditions gas leakage is prevented by direct contact between the seal and the rod.

  10. Dental Apical Papilla as Therapy for Spinal Cord Injury.

    Science.gov (United States)

    De Berdt, P; Vanacker, J; Ucakar, B; Elens, L; Diogenes, A; Leprince, J G; Deumens, R; des Rieux, A

    2015-11-01

    Stem cells of the apical papilla (SCAP) represent great promise regarding treatment of neural tissue damage, such as spinal cord injury (SCI). They derive from the neural crest, express numerous neurogenic markers, and mediate neurite outgrowth and axonal targeting. The goal of the present work was to investigate for the first time their potential to promote motor recovery after SCI in a rat hemisection model when delivered in their original stem cell niche-that is, by transplantation of the human apical papilla tissue itself into the lesion. Control groups consisted of animals subjected to laminectomy only (shams) and to lesion either untreated or injected with a fibrin hydrogel with or without human SCAP. Basso-Beattie-Bresnahan locomotor scores at 1 and 3 d postsurgery confirmed early functional decline in all SCI groups. This significant impairment was reversed, as seen in CatWalk analyses, after transplantation of apical papilla into the injured spinal cord wound, whereas the other groups demonstrated persistent functional impairment. Moreover, tactile allodynia did not develop as an unwanted side effect in any of the groups, even though the SCAP hydrogel group showed higher expression of the microglial marker Iba-1, which has been frequently associated with allodynia. Notably, the apical papilla transplant group presented with reduced Iba-1 expression level. Masson trichrome and human mitochondria staining showed the preservation of the apical papilla integrity and the presence of numerous human cells, while human cells could no longer be detected in the SCAP hydrogel group at the 6-wk postsurgery time point. Altogether, our data suggest that the transplantation of a human apical papilla at the lesion site improves gait in spinally injured rats and reduces glial reactivity. It also underlines the potential interest for the application of delivering SCAP in their original niche, as compared with use of a fibrin hydrogel. © International & American

  11. Shaft and tunnel sealing considerations

    International Nuclear Information System (INIS)

    Kelsall, P.C.; Shukla, D.K.

    1980-01-01

    Much of the emphasis of previous repository sealing research has been placed on plugging small diameter boreholes. It is increasingly evident that equal emphasis should now be given to shafts and tunnels which constitute more significant pathways between a repository and the biosphere. The paper discusses differences in requirements for sealing shafts and tunnels as compared with boreholes and the implications for seal design. Consideration is given to a design approach for shaft and tunnel seals based on a multiple component design concept, taking into account the requirements for retrievability of the waste. A work plan is developed for the future studies required to advance shaft and tunnel sealing technology to a level comparable with the existing technology for borehole sealing

  12. Rotatable seal assembly

    International Nuclear Information System (INIS)

    Garibaldi, J.L.; Logan, C.M.

    1982-01-01

    An assembly is provided for rotatably supporting a rotor on a stator so that vacuum chambers in the rotor and stator remain in communication while the chambers are sealed from ambient air, which enables the use of a ball bearing or the like to support most of the weight of the rotor. The apparatus includes a seal device mounted on the rotor to rotate therewith, but shiftable in position on the rotor while being sealed to the rotor as by an oring. The seal device has a flat face that is biased towards a flat face on the stator, and pressurized air is pumped between the faces to prevent contact between them while spacing them a small distance apart to avoid the inflow of large amounts of air between the faces and into the vacuum chambers

  13. Recent advances in magnetic liquid sealing

    International Nuclear Information System (INIS)

    Raj, K.; Stahl, P.; Bottenberg, W.; True, D.; Martis, G.; Zook, C.

    1979-01-01

    In this paper recent work in design and testing of two special magnetic liquid seals extending the state-of-the-art of ferrofluidic sealing is discussed. These custom seals are a moving belt edge seal and an exclusion seal. The first seal provides a hermetic barrier to solid particulates expected to be present in enclosed nuclear environments. The second seal is used on a magnetic disk drive spindle and reduces the particulate contaminants in the memory disk pack area by up to three orders of magnitude. In addition, bearing life in the spindle is found to be doubled due to reduction of operating temperature. The fundamentals of magnetic fluid sealing are presented in terms of magnetic circuit design and physical properties of ferrofluids

  14. Seal Related Development Activities at EG/G

    Science.gov (United States)

    Greiner, Harold F.

    1991-01-01

    Seal related development activities including modeling, analysis, and performance testing are described for several current seal related projects. Among the current seal related projects are the following: high pressure gas sealing systems for turbomachinery; brush seals for gas path sealing in gas turbines; and tribological material evaluation for wear surfaces in sealing systems.

  15. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A. [ABT Systems, LLC, Annville, PA (United States); Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  16. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  17. Fog seal guidelines.

    Science.gov (United States)

    2003-10-01

    Fog seals are a method of adding asphalt to an existing pavement surface to improve sealing or waterproofing, prevent further stone loss by holding aggregate in place, or simply improve the surface appearance. However, inappropriate use can result in...

  18. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    An apparatus is described for sealing a cold leg nozzle of a nuclear reactor pressure vessel from a remote location comprising: at least one sealing plug for mechanically sealing the nozzle from the inside of the reactor pressure vessel. The sealing plug includes a plate and a cone assembly having an end part receptive in the nozzle, the plate being axially moveable relative to the cone assembly. The plate and cone assembly have confronting bevelled edges defining an opening therebetween. A primary O-ring is disposed about the opening and is supported on the bevelled edges, the plate being guidably mounted to the cone assembly for movement toward the cone assembly to radially expand the primary O-ring into sealing engagement with the nozzle. A means is included for providing relative movement between the outer plate and the cone assembly

  19. A comparison of apical transportation between FlexMaster and Twisted Files rotary instruments.

    Science.gov (United States)

    Duran-Sindreu, Fernando; García, Marc; Olivieri, Juan Gonzalo; Mercadé, Montse; Morelló, Sergio; Roig, Miguel

    2012-07-01

    The aim of this study was to evaluate apical transportation in root canals after the use of Twisted Files (TF; SybronEndo, Orange, CA) and FlexMaster (VDW, Munich, Germany) #40/04 rotary files. A double-digital radiographic technique was used to compare apical transportation between the TF and FlexMaster systems. Each rotary system was used to instrument mesial canals from 80 extracted mandibular molars. The central axes of the file imaged before instrumentation (#15 K-file) and the master apical rotary file (#40/04) were superimposed digitally. AutoCAD 2008 (Autodesk Inc, San Rafael, CA) was used to measure apical transportation at 0.5 mm from the working length (WL). The data were analyzed using the Student's t test, and significance was set at P < .05. The mean amount of apical transportation at 0.5 mm from the WL was 0.17 ± 0.09 mm for the FlexMaster group and 0.19 ± 0.12 mm for the TF group. No statistically significant differences in apical transportation were found between the 2 groups. Under the conditions of the study, no statistically significant differences in apical transportation were observed between FlexMaster and TF rotary files. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. ROOT CANAL MICROORGANISMS PROFILES O F UPPER ANTERIOR TEETH WITH APICAL PERIODONTITIS

    OpenAIRE

    Tanumihardja, Maria; Riewpassa, Irene E; Mansjurnasir; Burhanuddin, DP

    2013-01-01

    Microorganisms are the main causative agents on the development of apical periodontitis. Microorganisms infecting the root canal system are colonized in communities as biofilm. These bacterial communities show distinct pattern related to the different forms of apical periodontitis which are determined by species richness and abundance. This study is aimed to examine the root canal microorganisms on upper anterior teeth of asymptomatic apical periodontitis and ch ronic api...

  1. Modulation of apical constriction by Wnt signaling is required for lung epithelial shape transition.

    Science.gov (United States)

    Fumoto, Katsumi; Takigawa-Imamura, Hisako; Sumiyama, Kenta; Kaneiwa, Tomoyuki; Kikuchi, Akira

    2017-01-01

    In lung development, the apically constricted columnar epithelium forms numerous buds during the pseudoglandular stage. Subsequently, these epithelial cells change shape into the flat or cuboidal pneumocytes that form the air sacs during the canalicular and saccular (canalicular-saccular) stages, yet the impact of cell shape on tissue morphogenesis remains unclear. Here, we show that the expression of Wnt components is decreased in the canalicular-saccular stages, and that genetically constitutive activation of Wnt signaling impairs air sac formation by inducing apical constriction in the epithelium as seen in the pseudoglandular stage. Organ culture models also demonstrate that Wnt signaling induces apical constriction through apical actomyosin cytoskeletal organization. Mathematical modeling reveals that apical constriction induces bud formation and that loss of apical constriction is required for the formation of an air sac-like structure. We identify MAP/microtubule affinity-regulating kinase 1 (Mark1) as a downstream molecule of Wnt signaling and show that it is required for apical cytoskeletal organization and bud formation. These results suggest that Wnt signaling is required for bud formation by inducing apical constriction during the pseudoglandular stage, whereas loss of Wnt signaling is necessary for air sac formation in the canalicular-saccular stages. © 2017. Published by The Company of Biologists Ltd.

  2. Microleakage, adaptation ability and clinical efficacy of two fluoride releasing fissure sealants

    Directory of Open Access Journals (Sweden)

    Marković Dejan

    2012-01-01

    Full Text Available Background/Aim. Retention of fissure sealants and good adaptation to enamel are essential for their success. Fluoride releasing resin-based materials are widely accepted for pit and fissure sealing, but newly designed glass ionomers can serve as a good alternative. The aim of this study was to evaluate microleakage and sealing ability in vitro, and to clinically assess two fluoride releasing fissure sealants. Methods. The sample for experimental study consisted of 20 freshly extracted intact human third molars, divided in two experimental groups according to the sealing material: fluoride releasing resin-based (Heliosel F and glass ionomer (Fuji Triage material. Digital images and scanning electron microscope were used to assess microleakage and adaptation ability. Sample for clinical study consisted of 60 children, aged 6-8 years, with high caries risk, divided in two groups according to the sealant material. Fissure sealant was applied to all erupted, caries-free first permanent molars. Sealants were evaluated after 3, 6 and 12 months using modified Ryge criteria for retention, marginal adaptation, colour match, surface smoothness and caries. Results. Microleakage was detected in more than half of the specimen, without significant differences between the two groups (p > 0.05. Both materials exhibited acceptable sealing ability. Complete retention at the end of the observation period was 81.8% for resin-based, and 21.1% for glass-ionomer fissure sealant (p < 0.001. The presence of caries in sealed molars has been detected in one patient in both groups. During the 12-month observation period, Helioseal F demonstrated better retention, marginal adaptation and surface smoothness (p < 0.001. There were no differences between the two materials regarding caries and color match (p > 0.05. Conclusion. Both tested materials demonstrate satisfactory clinical and caries prophylactic characteristics that justify their use in contemporary preventive

  3. Nonsurgical root canal therapy of large cyst-like inflammatory periapical lesions and inflammatory apical cysts.

    Science.gov (United States)

    Lin, Louis M; Ricucci, Domenico; Lin, Jarshen; Rosenberg, Paul A

    2009-05-01

    It is a general belief that large cyst-like periapical lesions and apical true cysts caused by root canal infection are less likely to heal after nonsurgical root canal therapy. Nevertheless, there is no direct evidence to support this assumption. A large cyst-like periapical lesion or an apical true cyst is formed within an area of apical periodontitis and cannot form by itself. Therefore, both large cyst-like periapical lesions and apical true cysts are of inflammatory and not of neoplastic origin. Apical periodontitis lesions, regardless of whether they are granulomas, abscesses, or cysts, fail to heal after nonsurgical root canal therapy for the same reason, intraradicular and/or extraradicular infection. If the microbial etiology of large cyst-like periapical lesions and inflammatory apical true cysts in the root canal is removed by nonsurgical root canal therapy, the lesions might regress by the mechanism of apoptosis in a manner similar to the resolution of inflammatory apical pocket cysts. To achieve satisfactory periapical wound healing, surgical removal of an apical true cyst must include elimination of root canal infection.

  4. Detection of seal contamination in heat-sealed food packaging based on active infrared thermography

    Science.gov (United States)

    D'huys, Karlien; Saeys, Wouter; De Ketelaere, Bart

    2015-05-01

    In the food industry packaging is often applied to protect the product from the environment, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the material used and the closure (seal). The material is selected based on the specific needs of the food product to be wrapped. However, proper closure of the package is often harder to achieve. One problem possibly jeopardizing seal quality is the presence of food particles between the seal. Seal contamination can cause a decreased seal strength and thus an increased packaging failure risk. It can also trigger the formation of microchannels through which air and microorganisms can enter and spoil the enclosed food. Therefore, early detection and removal of seal-contaminated packages from the production chain is essential. In this work, a pulsed-type active thermography method using the heat of the sealing bars as an excitation source was studied for detecting seal contamination. The cooling profile of contaminated seals was recorded. The detection performance of four processing methods (based on a single frame, a fit of the cooling profile, pulsed phase thermography and a matched filter) was compared. High resolution digital images served as a reference to quantify contamination. The lowest detection limit (equivalent diameter of 0.63 mm) and the lowest processing time (0.42 s per sample) were obtained for the method based on a single frame. Presumably, practical limitations in the recording stage prevented the added value of active thermography to be fully reflected in this application.

  5. Isotropic actomyosin dynamics promote organization of the apical cell cortex in epithelial cells.

    Science.gov (United States)

    Klingner, Christoph; Cherian, Anoop V; Fels, Johannes; Diesinger, Philipp M; Aufschnaiter, Roland; Maghelli, Nicola; Keil, Thomas; Beck, Gisela; Tolić-Nørrelykke, Iva M; Bathe, Mark; Wedlich-Soldner, Roland

    2014-10-13

    Although cortical actin plays an important role in cellular mechanics and morphogenesis, there is surprisingly little information on cortex organization at the apical surface of cells. In this paper, we characterize organization and dynamics of microvilli (MV) and a previously unappreciated actomyosin network at the apical surface of Madin-Darby canine kidney cells. In contrast to short and static MV in confluent cells, the apical surfaces of nonconfluent epithelial cells (ECs) form highly dynamic protrusions, which are often oriented along the plane of the membrane. These dynamic MV exhibit complex and spatially correlated reorganization, which is dependent on myosin II activity. Surprisingly, myosin II is organized into an extensive network of filaments spanning the entire apical membrane in nonconfluent ECs. Dynamic MV, myosin filaments, and their associated actin filaments form an interconnected, prestressed network. Interestingly, this network regulates lateral mobility of apical membrane probes such as integrins or epidermal growth factor receptors, suggesting that coordinated actomyosin dynamics contributes to apical cell membrane organization. © 2014 Klingner et al.

  6. Evaluation of the Apical Sealability of Mineral Trioxide Aggregate and Portland Cement as Root Canal Filling Cements: An in Vitro Study

    Directory of Open Access Journals (Sweden)

    M.S. Rekab

    2010-12-01

    Full Text Available Objective: One of the principle purposes of root canal obturation is to obtain hermetic sealing of the root canal system. According to the development of technology, many materials are now used in root canal filling. An in vitro dye leakage study was performed toevaluate the apical sealability of White-colored Mineral Trioxide Aggregate (WMTA and Gray-colored Portland Cement (GPC when used alone or as a sealer with gutta-percha points in root canal filling.Materials and Methods: Seventy-five single-rooted extracted human teeth were used in this study. After cleaning and shaping, the teeth were randomly divided into five equal groups of 15 teeth each based on the root canal filling material used; Group 1, (WMTAalone; Group 2, (GPC alone; Group 3, (Gutta-percha points + WMTA; Group 4,(Guttapercha points + GPC; Group 5, (Gutta-percha points + AH26. Methylene blue was used to determine the apical leakage. After sectioning the teeth longitudinally, linear dye penetrationwas measured with a caliper under the stereomicroscope. Data were analyzed by Kruskal-Wallis and one-way ANOVA tests with (P 0.05 as the level of significance.Results: The results showed that there were no statistically significant differences among the materials of five groups.Conclusion: (WMTA alone, (Gutta-percha points + WMTA, (GPC alone and (Guttapercha points + GPC may be used in the root canal filling.

  7. Sealing properties of cement-based grout materials. Final report on the Rock sealing project

    International Nuclear Information System (INIS)

    Onofrei, M.; Gray, Malcolm; Shenton, B.; Walker, Brad; Pusch, R.; Boergesson, L.; Karnland, O.

    1992-10-01

    This report presents the results of laboratory studies of material properties. A number of different high performance grouts were investigated. The laboratory studies focused on mixtures of sulphate resistant portland cement, silica fume, superplasticizer and water. The ability of the thin films to self seal was confirmed. The surface reactions were studied in specimens of hardened grouts. The leach rates were found to vary with grout and water composition and with temperature. The short-term hydraulic and strength or properties of the hardened grout were determined. These properties were determined for the grouts both in-bulk and as thin-films. The hydraulic conductivities of the bulk, hardened material were found to be less than 10 -14 m/s. The hydraulic conductivities of thin films were found to be less than 10 -11 m/s. Broken, the hydraulic conductivity of the thin films could be increased to 10 -7 m/s. Examination of the leached grout specimens revealed a trend for the pore sizes to decrease with time. The propensity for fractured grouts to self seal was also observed in tests in which the hydraulic conductivity of recompacted mechanically disrupted, granulated grouts was determined. These tests showed that the hydraulic conductivity decreased rapidly with time. The decreases were associated with decreases in mean pore size. In view of the very low hydraulic conductivity it is likely that surface leaching at the grout/groundwater interface will be that major process by which bulk high-performance grouts may degrade. With the completion of the laboratory, in situ and modelling studies it appears that high-performance cement based grouts can be considered as viable materials for some repository sealing applications. Some of the uncertainties that remain are identified in this report. (54 refs.)

  8. Bone resorptive activity in symptomatic and asymptomatic apical lesions of endodontic origin

    OpenAIRE

    Salinas-Muñoz, M.; Garrido-Flores, M.; Baeza, M.; Huamán-Chipana, P.; García-Sesnich, J.; Bologna, R.; Vernal, R.; Hernández, M.

    2017-01-01

    Objectives The aim of this study is to assess the levels and diagnostic accuracy of a set of bone resorption biomarkers, including TRAP-5, RANKL, and OPG in symptomatic and asymptomatic apical lesions and controls. Materials and methods Apical tissues from symptomatic and asymptomatic apical periodontitis patients and periodontal ligaments from healthy teeth extracted for orthodontic reasons were processed for tissue homogenization and the levels of TRAP-5, RANKL, and OPG were determined by m...

  9. Shaft Seal Compensates for Cold Flow

    Science.gov (United States)

    Myers, W. N.; Hein, L. A.

    1985-01-01

    Seal components easy to install. Ring seal for rotating or reciprocating shafts spring-loaded to compensate for slow yielding (cold flow) of sealing material. New seal relatively easy to install because components preassembled, then installed in one piece.

  10. Film riding seals for rotary machines

    Science.gov (United States)

    Bidkar, Rahul Anil; Sarawate, Neelesh Nandkumar; Wolfe, Christopher Edward; Ruggiero, Eric John; Raj Mohan, Vivek Raja

    2017-03-07

    A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further, the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.

  11. Low-Torque Seal Development

    Science.gov (United States)

    Lattime, Scott B.; Borowski, Richard

    2009-01-01

    The EcoTurn Class K production prototypes have passed all AAR qualification tests and received conditional approval. The accelerated life test on the second set of seals is in progress. Due to the performance of the first set, no problems are expected.The seal has demonstrated superior performance over the HDL seal in the test lab with virtually zero torque and excellent contamination exclusion and grease retention.

  12. [A retrospective study of 180 cases of apical microsurgery].

    Science.gov (United States)

    Wang, Hanguo; Li, Dan; Tian, Yu; Yu, Qing

    2014-07-01

    To evaluate the outcome and the potential prognostic factors of apical microsurgery. The teeth with persistent periapical diseases were treated by microsurgery using micro instruments, ultrasonic retrotips and mineral trioxide aggregate (MTA) under dental operate microscope. The procedure includes incision and flap retraction, osteotomy, apicoectomy, retro- preparation and retro- filling of root canal. Patients were recalled at 1, 3, 6, and 12- month intervals. The outcome was evaluated by clinical and radiographic examinations, and the potential prognostic factors were analyzed. One hundred and eighty cases (240 teeth), including 132 upper anterior teeth, 22 lower anterior teeth, 31 upper premolars, 18 lower premolars, 19 upper molars and 18 lower molars, were treated by microsurgery between July 2010 and December 2012. A total of 152 cases (207 teeth) were recalled. The application of the apical microsurgery included failure of previous endodontic treatment, periapical lesion with post, periapical cyst, calcified canals, separated instruments, overfilling, open apex, root facture, failure of previous apical surgery, apical fenestration, and special root canal system. The success rate was 90.8% (188/207). Age, sex, tooth position, type of periapical radiolucency, fistula and clinical application type appeared to have a negative effect on the outcome. Endo-perio lesion was a significant factor. Eighteen cases (19 teeth) failed mainly because of periodontally involved lesion and vertical root fracture. Apical microsurgery, which combines the magnification and illumination provided by the microscope with the proper use of micro instruments, can treat the teeth with persistent periapical diseases precisely and less traumatically with high success rate. Case selection and standardized operations play a key role for success.

  13. Spontaneous coronary artery dissection associated with apical hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Tuncer, M.; Gumrukcuoglu, H.A.; Ekim, H.; Gunes, Y.; Simsek, H.

    2010-01-01

    Apical hypertrophic cardiomyopathy (HCM) is a relatively uncommon inherited disease. Spontaneous coronary artery dissection (SCAD) is also uncommonly observed, which often occurs in pregnant or post partum women but is rare in men. This report describes a 38 years old man with apical hypertrophic cardiomyopathy who developed SCAD leading to acute inferior myocardial infarction. After emergent appendectomy operation at another hospital, he was immediately transferred to the Cardiology Department of our hospital due to acute myocardial infarction. He emergently underwent coronary angiography which showed a long dissection involving the right coronary. He underwent an emergent CABG with cardiopulmonary bypass. Postoperative recovery was uneventful and he was discharged. According to our knowledge, no case of spontaneous coronary artery dissection associated with apical hypertrophic cardiomyopathy unrelated to postpartum period or oral contraceptive use has been reported so far. (author)

  14. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  15. Reactor cavity seal ring

    International Nuclear Information System (INIS)

    Hankinson, M.F.

    1986-01-01

    A hydrostatic seal is described for sealing an annular gap between two flat substantially horizontal coplanar surfaces comprising, in combination: a generally flat annular plate of a width sufficient to span a gap between two surfaces: compressible annular sealing means disposed on the bottom surface of the flat annular plate for sealingly engaging the two flat surfaces in response to a downward force exerted on the plate; and fastening means, distributed along the center line of the plate, for releasably fastening the plate in a position to span the gap to be sealed and exert a downward force on the plate, each fastening means including a pair of elongated members of a size to fit into the gap to be sealed, means for mounting the members on the bottom surface of the plate so that at least a portion of each member is radially moveable in a direction toward a respective one of the vertical side surfaces defining the gap to be sealed to engage same and so that the plate is moveable relative to the members in a downward direction in response to hydrostatic pressure applied to the upper surface of the plate when the members are engaging the vertical side surfaces of an annular gap, and an actuating means, mounted on the plate for movement therewith in response to hydrostatic pressure, for radially moving the members, the actuating means extending through a bore in the plate to the upper surface of the plate

  16. Design considerations for mechanical face seals

    Science.gov (United States)

    Ludwig, L. P.; Greiner, H. F.

    1980-01-01

    Two companion reports deal with design considerations for improving performance of mechanical face seals, one of family of devices used in general area of fluid sealing of rotating shafts. One report deals with basic seal configuration and other with lubrication of seal.

  17. Racing performance after arthroscopic removal of apical sesamoid fracture fragments in Thoroughbred horses age < 2 years: 151 cases (1989--2002).

    Science.gov (United States)

    Schnabel, L V; Bramlage, L R; Mohammed, H O; Embertson, R M; Ruggles, A J; Hopper, S A

    2007-01-01

    Studies on arthroscopic removal of apical proximal sesamoid fracture fragments in Thoroughbred (TB) horses age > or = 2 years have reported a high success rate. However, there are no reports documenting the racing prognosis of TB horses that undergo such surgery as weanlings or yearlings. To describe the incidence of apical proximal sesamoid fractures in immature TB horses, age fractures in 151 TB weanlings and yearlings. The medical records of TB horses age fracture fragments were reviewed. Follow-up information was obtained from race records. Student's t tests were used to compare performance variables of operated racehorses to that of their maternal siblings. Ninety-two percent (139/151) of fractures occurred in the hindlimbs and 8% (11/151) in the forelimbs (fracture of both fore- and hindlimb, n = 1). Horses with forelimb fractures had a greatly reduced probability of racing (55%) compared to those with hindlimb fractures (86%). Overall, 84% of the horses raced post operatively and had performance records similar to that of their maternal siblings, 78% (787/1006) of which raced. Arthroscopic removal of apical proximal sesamoid fracture fragments in TB weanlings and yearlings carries an excellent prognosis for racing in horses with hindlimb fractures and a reduced prognosis in those with forelimb fractures. Medial fractures of the forelimb carry the worst prognosis. The determination of prognosis increases knowledge on apical sesamoid bone fractures and potential for arthroscopic restoration of the ability to race; and enables the value of yearlings for subsequent sale to be established.

  18. Apical surgery vs apical surgery with simultaneous orthograde retreatment: A prospective cohort clinical study of teeth affected by persistent periapical lesion

    Directory of Open Access Journals (Sweden)

    Carlo Prati

    2018-06-01

    Full Text Available Aim: This prospective clinical study analyzed the 24-month outcome of conventional apical surgery retro-filled with calcium-silicate cement versus apical surgery with simultaneous orthograde retreatment by means of clinical and radiographic criteria. Materials and methods: This study included 83 teeth affected by persistent periapical lesions in 68 patients. Mean age was 52 years (median = 51 years; range 19–81 years. Twenty-eight cases were treated with apical surgery, 16 cases with apical surgery with simultaneous orthograde retreatment and 39 cases with orthograde retreatment in previously treated teeth established as control group. Periapical index score (PAI was used as radiographic criteria. Teeth were examined at 6 months, 1 and 2 years and classified as healed (without any symptoms and PAI ≤ 2, healing (without any symptoms and PAI = 3 or diseased (with symptoms or PAI ≥ 4 and not functional on the basis of radiographic and clinical criteria. At 24 months evaluation, healed and healing were considered as success and diseased and fracture as failure. Multilevel GLM model and an ordered logistic regression as statistical analysis was made with level of significance set at p < 0.05. Results: Total drop-out was 7% (n = 6. After 6–9 months, 6 teeth (3 from apical surgery, 2 from simultaneous treatment and 1 from orthograde retreatment were extracted for root fracture. Twenty-four-month success rate of apical surgery group was 78% (n = 17, apical surgery with simultaneous orthograde retreatment presented 81% (n = 10 and orthograde retreatment success was 80% (n = 24. There was no statistically difference between the groups at 24 months (p = 0.890. Conclusions: Both surgical techniques revealed a high percentage of healing, similar to that reported by previous studies. Apical surgery with simultaneous orthograde retreatment showed a faster healing after 12 months comparing to the control group. Riassunto: Scopo: In

  19. Participation of gibberellin in the control of apical dominance in soybean and redwood

    Energy Technology Data Exchange (ETDEWEB)

    Ruddat, M.; Pharis, R.P.

    1966-01-01

    Loss of apical dominance in soybeans and redwood was increased when the plants were treated with the growth retardant AMO-1618. Simultaneous application of gibberellin reduced the number of elongating buds and promoted growth of the first or second uppermost auxillary bud, thus restoring apical dominance. It is concluded that gibberellin participates in the expression of apical dominance. 30 references, 2 tables.

  20. Viral-bacterial associations in acute apical abscesses.

    Science.gov (United States)

    Ferreira, Dennis C; Rôças, Isabela N; Paiva, Simone S M; Carmo, Flávia L; Cavalcante, Fernanda S; Rosado, Alexandre S; Santos, Kátia R N; Siqueira, José F

    2011-08-01

    Viral-bacterial and bacterial synergism have been suggested to contribute to the pathogenesis of several human diseases. This study sought to investigate the possible associations between 9 candidate endodontic bacterial pathogens and 9 human viruses in samples from acute apical abscesses. DNA extracts from purulent exudate aspirates of 33 cases of acute apical abscess were surveyed for the presence of 9 selected bacterial species using a 16S ribosomal RNA gene-based nested polymerase chain reaction (PCR) approach. Single or nested PCR assays were used for detection of the human papillomavirus (HPV) and herpesviruses types 1 to 8. Two-thirds of the abscess samples were positive for at least one of the target viruses. Specifically, the most frequently detected viruses were HHV-8 (54.5%); HPV (9%); and varicella zoster virus (VZV), Epstein-Barr virus (EBV), and HHV-6 (6%). Bacterial DNA was present in all cases and the most prevalent bacterial species were Treponema denticola (70%), Tannerella forsythia (67%), Porphyromonas endodontalis (67%), Dialister invisus (61%), and Dialister pneumosintes (57.5%). HHV-8 was positively associated with 7 of the target bacterial species and HPV with 4, but all these associations were weak. Several bacterial pairs showed a moderate positive association. Viral coinfection was found in 6 abscess cases, but no significant viral association could be determined. Findings demonstrated that bacterial and viral DNA occurred concomitantly in two-thirds of the samples from endodontic abscesses. Although this may suggest a role for viruses in the etiology of apical abscesses, the possibility also exists that the presence of viruses in abscess samples is merely a consequence of the bacterially induced disease process. Further studies are necessary to clarify the role of these viral-bacterial interactions, if any, in the pathogenesis of acute apical abscesses. Copyright © 2011 Mosby, Inc. All rights reserved.

  1. Impaired immune function in seals and laboratory rats exposed to dioxin-like compounds from Baltic herring

    Energy Technology Data Exchange (ETDEWEB)

    Ross, P.S. [Seal Rehabilitation and Research Centre, Pieterburen (Netherlands)]|[National Inst. of Public Health and Environmental Protection, Bilthoven (Netherlands); Swart, R.L. de [Seal Rehabilitation and Research Centre, Pieterburen (Netherlands)]|[Erasmus Univ., Rotterdam (Netherlands); Timmerman, H.H.; Loveren, H. van [National Inst. of Public Health and Environmental Protection, Bilthoven (Netherlands); Osterhaus, A.D.M.E. [Seal Rehabilitation and Research Centre, Pieterburen (Netherlands)]|[National Inst. of Public Health and Environmental Protection, Bilthoven (Netherlands)]|[Erasmus Univ., Rotterdam (Netherlands)

    1995-12-31

    Complex mixtures of lipophilic contaminants have been shown to affect certain top predators in the aquatic food chain, including seals. A recent demonstration that harbor seals (Phoca vitulina) fed Baltic Sea herring displayed impaired natural killer cell activity and T-lymphocyte function represented the first demonstration of immunotoxicity induced by ambient levels of contaminants in the environment. While these animals had a lower ability to respond to immunizations with inactivated vaccines, specific antibody responses, and in vitro antigen-specific lymphoproliferative responses, obvious constraints limited the ability to extend these results with host resistance tests or an evaluation of thymus and other lymphoid organs. The authors therefore set up a parallel study by exposing pregnant laboratory rats to the same Baltic herring contaminant mixture as received the seals. They then examined immune function parameters and host resistance to virus infection. As in the seals, rat pups of the Baltic group had impaired T-lymphocyte function. In addition, thymus cells and/or their precursors appeared to be targeted, as their numbers and function were reduced in the rats. Following challenge with rat cytomegalovirus in a host resistance study, rat pups in the Baltic group had impaired natural killer cell responses to the virus infection, and lower specific CD8 + (cytotoxic T-lymphocyte) responses following in vitro stimulation. By extrapolation, these results suggest that the impaired immune responses observed in the Baltic group of seals may lead to a less effective defense against virus infections in marine mammals inhabiting polluted coastal waters. Toxicological profiles and results of both the captive seal and laboratory rat experiments tend to implicate the 2,3,7,8-TCDD-like PCB, dioxin and furan congeners in the immunosuppression, and point to a major role for the PCBs.

  2. EBR-II rotating plug seal maintenance

    International Nuclear Information System (INIS)

    Allen, K.J.

    1986-01-01

    The EBR-II rotating plug seals require frequent cleaning and maintenance to keep the plugs from sticking during fuel handling. Time consuming cleaning on the cover gas and air sides of the dip ring seal is required to remove oxidation and sodium reaction products that accumulate and stop plug rotation. Despite severely limited access, effective seal cleaning techniques have removed 11 800 lb (5 352 kg) of deposits from the seals since 1964. Temperature control modifications and repairs have also required major maintenance work. Suggested seal design recommendations could significantly reduce maintenance on future similar seals

  3. The resection angle in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Janner, Simone F M; Jensen, Simon S

    2016-01-01

    OBJECTIVES: The primary objective of the present radiographic study was to analyse the resection angle in apical surgery and its correlation with treatment outcome, type of treated tooth, surgical depth and level of root-end filling. MATERIALS AND METHODS: In the context of a prospective clinical...... study, cone beam computed tomography (CBCT) scans were taken before and 1 year after apical surgery to measure the angle of the resection plane relative to the longitudinal axis of the root. Further, the surgical depth (distance from the buccal cortex to the most lingual/palatal point of the resection...... or with the retrofilling length. CONCLUSIONS: Statistically significant differences were observed comparing resection angles of different tooth groups. However, the angle had no significant effect on treatment outcome. CLINICAL RELEVANCE: Contrary to common belief, the resection angle in maxillary anterior teeth...

  4. Tamper-indicating quantum optical seals

    Energy Technology Data Exchange (ETDEWEB)

    Humble, Travis S [ORNL; Williams, Brian P [ORNL

    2015-01-01

    Confidence in the means for identifying when tampering occurs is critical for containment and surveillance technologies. Fiber-optic seals have proven especially useful for actively surveying large areas or inventories due to the extended transmission range and flexible layout of fiber. However, it is reasonable to suspect that an intruder could tamper with a fiber-optic sensor by accurately replicating the light transmitted through the fiber. In this contribution, we demonstrate a novel approach to using fiber-optic seals for safeguarding large-scale inventories with increased confidence in the state of the seal. Our approach is based on the use of quantum mechanical phenomena to offer unprecedented surety in the authentication of the seal state. In particular, we show how quantum entangled photons can be used to monitor the integrity of a fiber-optic cable - the entangled photons serve as active sensing elements whose non-local correlations indicate normal seal operation. Moreover, we prove using the quantum no-cloning theorem that attacks against the quantum seal necessarily disturb its state and that these disturbances are immediately detected. Our quantum approach to seal authentication is based on physical principles alone and does not require the use of secret or proprietary information to ensure proper operation. We demonstrate an implementation of the quantum seal using a pair of entangled photons and we summarize our experimental results including the probability of detecting intrusions and the overall stability of the system design. We conclude by discussing the use of both free-space and fiber-based quantum seals for surveying large areas and inventories.

  5. Apically-extruded debris using the ProTaper system.

    Science.gov (United States)

    Azar, Nasim Gheshlaghi; Ebrahimi, Gholamreza

    2005-04-01

    The purpose of this in vitro study was to determine the quantity of debris and irrigant extruded apically using the ProTaper system compared to ProFiles and K-Flexofiles. Thirty-six mesio-buccal root canals of human mandibular molars were selected and divided into three groups of twelve canals. Two groups were instrumented with ProFiles and ProTapers according to the manufacturer's instructions. The other group was instrumented with K-Flexofiles using the step-back technique. A standard amount of irrigant was used for each canal. Apically-extruded debris and irrigant was collected in pre-weighed vials. The mean weight of extruded debris and irrigant for each group was statistically analysed using Student's t-test and one-way ANOVA. All instrumentation techniques produced extruded debris and irrigant. Although the mean amount of extrusion with the step-back technique was higher than the two rotary systems, there was no significant difference between the three groups (p > 0.05). NiTi rotary systems were associated with less apical extrusion, but were not significantly better than hand file instrumentation. All techniques extruded debris.

  6. Repository Closure and Sealing Approach

    International Nuclear Information System (INIS)

    A.T. Watkins

    2000-01-01

    The scope of this analysis will be to develop the conceptual design of the closure seals and their locations in the Subsurface Facilities. The design will be based on the recently established program requirements for transitioning to the Site Recommendation (SR) design as outlined by ''Approach to Implementing the Site Recommendation Baseline'' (Stroupe 2000) and the ''Monitored Geologic Repository Project Description Document'' (CRWMS M andO 1999b). The objective of this analysis will be to assist in providing a description for the Subsurface Facilities System Description Document, Section 2 and finally to document any conclusions reached in order to contribute and provide support to the SR. This analysis is at a conceptual level and is considered adequate to support the SR design. The final closure barriers and seals for the ventilation shafts, and the north and south ramps will require these openings to be permanently sealed to limit excessive air and water inflows and prevent human intrusion. The major tasks identified with closure in this analysis are: (1) Developing the overall subsurface seal layout and identifying design and operational interfaces for the Subsurface Facilities. (2) Summarizing the general site conditions and general rock characteristic with respect to seal location and describing the seal selected. (3) Identify seal construction materials, methodology of construction and strategic locations including design of the seal and plugs. (4) Discussing methods to prevent human intrusion

  7. Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars

    OpenAIRE

    Abarca, J.; Zaror, C.; Monardes, H.; Hermosilla, V.; Muñoz, C.; Cantin, M.

    2014-01-01

    Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3–5 mm from the apex were sect...

  8. Air riding seal with purge cavity

    Science.gov (United States)

    Sexton, Thomas D; Mills, Jacob A

    2017-08-15

    An air riding seal for a turbine in a gas turbine engine, where an annular piston is axial moveable within an annular piston chamber formed in a stator of the turbine and forms a seal with a surface on the rotor using pressurized air that forms a cushion in a pocket of the annular piston. A purge cavity is formed on the annular piston and is connected to a purge hole that extends through the annular piston to a lower pressure region around the annular piston or through the rotor to an opposite side. The annular piston is sealed also with inner and outer seals that can be a labyrinth seal to form an additional seal than the cushion of air in the pocket to prevent the face of the air riding seal from overheating.

  9. Seals in nuclear reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The aim of this invention is the provision of improved seals for reactor vessels in which fuel assemblies are located together with inlets and outlets for the circulation of a coolant. The object is to provide a seal arrangement for the rotatable plugs of nuclear reactor closure heads which has good sealing capacities over a wide gap during operation of the reactor but which also permits uninhibited rotation of the plugs for maintenance. (U.K.)

  10. Self-acting and hydrodynamic shaft seals

    Science.gov (United States)

    Ludwig, L. P.

    1973-01-01

    Self-acting and hydrodynamic seals are described. The analytical procedures are outlined for obtaining a seal force balance and the operating film thickness. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis revealed three different vibration modes. Proposed applications of self-acting seals in gas turbine engines and in rocket vehicle turbopumps are described. Also experimental data on self-acting face seals operating under simulated gas turbine conditions are given; these data show the feasibility of operating the seal at conditions of 345 newtons per square centimeter (500 psi) and 152 meters per second (500 ft/sec) sliding speed.

  11. Radial lip seals, thermal aspects

    NARCIS (Netherlands)

    Stakenborg, M.J.L.; van Ostaijen, R.A.J.; Dowson, D.

    1989-01-01

    In this paper the influence of temperature on tne seal-snarc contact is studied, using coupled temperature-stress FEH analysis. A thermal network model is used to calculate the seal-shaft contact temperature for steady-state and transient conditions. Contact temperatures were measured under the seal

  12. Airfoil seal system for gas turbine engine

    Science.gov (United States)

    None, None

    2013-06-25

    A turbine airfoil seal system of a turbine engine having a seal base with a plurality of seal strips extending therefrom for sealing gaps between rotational airfoils and adjacent stationary components. The seal strips may overlap each other and may be generally aligned with each other. The seal strips may flex during operation to further reduce the gap between the rotational airfoils and adjacent stationary components.

  13. Analysis on the Viscous Pumping in a Magnetic Fluid Seal Under a Rotating Load and the Seal Design

    OpenAIRE

    長屋, 幸助; 大沼, 浩身; 佐藤, 淳

    1990-01-01

    This paper discusses effects of viscous pumping in a magnetic fluid seal under a rotating load. The Reynolds equation was presented for the seal based on magnetic fluid mechanics, and the expressions for obtaining pressures in the seal, eccentricities of the rotating shaft due to the viscous pumping and seal pressures were given. Numerical Calculations were carried out for some sample problems, and the effect of magnetic flux densities on the pressure in the seal and the seal pressures were c...

  14. Albinistic common seals (Phoca vitulina) and melanistic grey seals (Halichoerus grypus) rehabilitated in the Netherlands

    NARCIS (Netherlands)

    Osinga, Nynke; 't Hart, Pieter; Vader, Pieter C. van Voorst

    2010-01-01

    The Seal Rehabilitation and Research Centre (SRRC) in Pieterburen, The Netherlands, rehabilitates seals from the waters of the Wadden Sea, North Sea and Southwest Delta area. Incidental observations of albinism and melanism in common and grey seals are known from countries surrounding the North Sea.

  15. Micro‐CT analyses of apical enlargement and molar root canal complexity

    DEFF Research Database (Denmark)

    Markvart, M.; Darvann, Tron Andre; Larsen, P.

    2012-01-01

    Markvart M, Darvann TA, Larsen P, Dalstra M, Kreiborg S, Bjørndal L. Micro‐CT analyses of apical enlargement and molar root canal complexity. International Endodontic Journal, 45, 273–281, 2012. Aim To compare the effectiveness of two rotary hybrid instrumentation techniques with focus on apical...

  16. Enhanced sealing project: monitoring the THM response of a full-scale shaft seal

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, D.A.; Martino, J.B.; Holowick, B.; Priyanto, D. [Atomic Energy of Canada Limited, Pinawa, MB (Canada)

    2011-07-01

    Closure of the subsurface facilities at Atomic Energy of Canada Limited's (AECL) Underground Research Laboratory (URL) was completed in 2010 with installation of a concrete surface cap. Additionally, as part of decommissioning, seals were installed at the penetration of the shafts through the major hydro-geological feature known as Fracture Zone 2 (FZ2). The seal construction was funded by Natural Resources Canada (NRCan) under the Nuclear Legacy Liabilities Program (NLLP). The shaft seals at the URL were based on the composite seal concept developed for application in a deep geological repository for disposal of used nuclear fuel. The access shaft seal consists of two 3-m thick concrete segments that rigidly confine a 6-m long section of swelling clay-based material (40% bentonite clay - 60% sand by dry mass). Monitoring of the regional groundwater recovery following flooding of the lower shaft is a closure requirement and was included in the design. It was widely recognized that the installation of the seals at the URL represented a unique opportunity to monitor the evolution of the type of seal that might be installed in an actual repository but the NLLP mandate did not include any monitoring of shaft seal evolution. As a result the Enhanced Sealing Project (ESP) partnership composed of NWMO, Posiva, SKB and ANDRA was established and a set of 68 instruments (containing 100 sensors) were installed to monitor the evolution of the seal. In the first year of operation sensors have monitored the following parameters in the ESP: thermal evolution and strain of the concrete components, thermal, hydraulic and mechanical changes in the clay component and its contacts with the rock and concrete confinement. Additionally, monitoring of the near-field and regional groundwater evolution has been undertaken. Monitoring of the short-term thermal-mechanical evolution of the concrete components was successfully accomplished and only a small temperature rise occurred due to

  17. Enhanced sealing project: monitoring the THM response of a full-scale shaft seal

    International Nuclear Information System (INIS)

    Dixon, D.A.; Martino, J.B.; Holowick, B.; Priyanto, D.

    2011-01-01

    Closure of the subsurface facilities at Atomic Energy of Canada Limited's (AECL) Underground Research Laboratory (URL) was completed in 2010 with installation of a concrete surface cap. Additionally, as part of decommissioning, seals were installed at the penetration of the shafts through the major hydro-geological feature known as Fracture Zone 2 (FZ2). The seal construction was funded by Natural Resources Canada (NRCan) under the Nuclear Legacy Liabilities Program (NLLP). The shaft seals at the URL were based on the composite seal concept developed for application in a deep geological repository for disposal of used nuclear fuel. The access shaft seal consists of two 3-m thick concrete segments that rigidly confine a 6-m long section of swelling clay-based material (40% bentonite clay - 60% sand by dry mass). Monitoring of the regional groundwater recovery following flooding of the lower shaft is a closure requirement and was included in the design. It was widely recognized that the installation of the seals at the URL represented a unique opportunity to monitor the evolution of the type of seal that might be installed in an actual repository but the NLLP mandate did not include any monitoring of shaft seal evolution. As a result the Enhanced Sealing Project (ESP) partnership composed of NWMO, Posiva, SKB and ANDRA was established and a set of 68 instruments (containing 100 sensors) were installed to monitor the evolution of the seal. In the first year of operation sensors have monitored the following parameters in the ESP: thermal evolution and strain of the concrete components, thermal, hydraulic and mechanical changes in the clay component and its contacts with the rock and concrete confinement. Additionally, monitoring of the near-field and regional groundwater evolution has been undertaken. Monitoring of the short-term thermal-mechanical evolution of the concrete components was successfully accomplished and only a small temperature rise occurred due to

  18. 19 CFR 113.25 - Seals.

    Science.gov (United States)

    2010-04-01

    ... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... law of the state in which executed. However, when the charter or governing statute of a corporation requires its acts to be evidenced by its corporate seal, such seal is required. ...

  19. Balance between Apical Membrane Growth and Luminal Matrix Resistance Determines Epithelial Tubule Shape

    Directory of Open Access Journals (Sweden)

    Bo Dong

    2014-05-01

    Full Text Available The morphological stability of biological tubes is crucial for the efficient circulation of fluids and gases. Failure of this stability causes irregularly shaped tubes found in multiple pathological conditions. Here, we report that Drosophila mutants of the ESCRT III component Shrub/Vps32 exhibit a strikingly elongated sinusoidal tube phenotype. This is caused by excessive apical membrane synthesis accompanied by the ectopic accumulation and overactivation of Crumbs in swollen endosomes. Furthermore, we demonstrate that the apical extracellular matrix (aECM of the tracheal tube is a viscoelastic material coupled with the apical membrane. We present a simple mechanical model in which aECM elasticity, apical membrane growth, and their interaction are three vital parameters determining the stability of biological tubes. Our findings demonstrate a mechanical role for the extracellular matrix and suggest that the interaction of the apical membrane and an elastic aECM determines the final morphology of biological tubes independent of cell shape.

  20. Balance between apical membrane growth and luminal matrix resistance determines epithelial tubule shape.

    Science.gov (United States)

    Dong, Bo; Hannezo, Edouard; Hayashi, Shigeo

    2014-05-22

    The morphological stability of biological tubes is crucial for the efficient circulation of fluids and gases. Failure of this stability causes irregularly shaped tubes found in multiple pathological conditions. Here, we report that Drosophila mutants of the ESCRT III component Shrub/Vps32 exhibit a strikingly elongated sinusoidal tube phenotype. This is caused by excessive apical membrane synthesis accompanied by the ectopic accumulation and overactivation of Crumbs in swollen endosomes. Furthermore, we demonstrate that the apical extracellular matrix (aECM) of the tracheal tube is a viscoelastic material coupled with the apical membrane. We present a simple mechanical model in which aECM elasticity, apical membrane growth, and their interaction are three vital parameters determining the stability of biological tubes. Our findings demonstrate a mechanical role for the extracellular matrix and suggest that the interaction of the apical membrane and an elastic aECM determines the final morphology of biological tubes independent of cell shape. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Choice of rotatable plug seals for prototype fast breeder reactor: Review of historical perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, N.K., E-mail: nksinha@igcar.gov.in; Raj, Baldev, E-mail: baldev.dr@gmail.com

    2015-09-15

    Highlights: • Choice and arrangement of elastomeric inflatable and backup seals as primary and secondary barriers. • With survey (mid-1930s onwards) of reactor, sealing, R&D and rubber technology. • Load, reliability, safety, life and economy of seals and reactors are key factors. • PFBR blends concepts and experience of MOX fuelled FBRs with original solutions. • R&D indicates inflatable seal advanced fluoroelastomer pivotal in unifying nuclear sealing. - Abstract: Choice and arrangement of elastomeric primary inflatable and secondary backup seals for the rotatable plugs (RPs) of 500 MW (e), sodium cooled, pool type, 2-loop, mixed oxide (MOX) fuelled Prototype Fast Breeder Reactor (PFBR) is depicted with review of various historical perspectives. Static and dynamic operation, largest diameters (PFBR: ∼6.4 m, ∼4.2 m), widest gaps and variations (5 ± 2 mm) and demanding operating requirements make RP openings on top shield (TS) the most difficult to seal which necessitated extensive development from 1950s to early 1990s. Liquid metal freeze seals with life equivalent to reactor prevailed as primary barrier (France, Japan, U.S.S.R.) during pre-1980s in spite of bulk, cost and complexity due to the abilities to meet zero leakage and resist core disruptive accident (CDA). Redefinition of CDA as beyond design basis accident, tolerable leakage and enhanced economisation drive during post-1980s established elastomeric inflatable seal as primary barrier excepting in U.S.S.R. (MOX fuel, freeze seal) and U.S.A. (metallic fuel). Choice of inflatable seal for PFBR RPs considers these perspectives, inherent advantages of elastomers and those of inflatable seals which maximise seal life. Choice of elastomeric backup seal as secondary barrier was governed by reliability and minimisation as well as distribution of load (temperature, radiation, mist) to maximise seal life. The compact sealing combination brings the hanging RPs at about the same elevation to reduce

  2. Gravity-induced buds formation from protonemata apical cells in the mosses

    Science.gov (United States)

    Kyyak, Natalia; Khorkavtsiv, Yaroslava

    The acceleration of moss protonemata development after the exit it to light from darkness is important gravidependent morphogenetic manifestation of the moss protonemata. The accelerated development of mosses shows in transformation of apical protonemata cells into the gametophores buds (Ripetskyj et al., 1999). In order to establish, that such reaction on gravitation is general property of gravisensity species, or its typical only for single moss species, experiments with the following moss species - Bryum intermedium (Ludw.) Brig., Bryum caespiticium Hedw., Bryum argenteum Hedw., Dicranodontium denudatum (Brid.) Britt. were carried out. All these species in response to influence of gravitation were capable to form rich bunches of gravitropical protonemata in darkness, that testified to their gravisensity. After the transference of Petri dishes with gravitropical protonemata from darkness on light was revealed, that in 3 of the investigated species the gametophores buds were absent. Only B. argenteum has reacted to action of gravitation by buds formation from apical cells of the gravitropical protonemata. With the purpose of strengthening of buds formation process, the experiments with action of exogenous kinetin (in concentration of 10 (-6) M) were carried out. Kinetin essentially stimulated apical buds formation of B. argenteum. The quantity of apical buds has increased almost in three times in comparison with the control. Besides, on separate stolons a few (3-4) buds from one apical cell were formed. Experimentally was established, that the gametophores buds formation in mosses is controlled by phytohormones (Bopp, 1985; Demkiv et al., 1991). In conditions of gravity influence its essentially accelerated. Probably, gravity essentially strengthened acropetal transport of phytohormones and formation of attractive center in the protonemata apical cell. Our investigations have allowed to make the conclusion, that gravi-dependent formation of the apical buds is

  3. Hypertrophic cardiomyopathy with mid-ventricular obstruction and apical aneurysm

    Directory of Open Access Journals (Sweden)

    N.D. Oryshchyn

    2016-11-01

    Full Text Available A case report of apical left ventricular aneurysm in patient with hypertrophic cardiomyopathy with mid-ventricular obstruction (diagnosis and surgical treatment is presented. We revealed apical aneurysm and mid-ventricular obstruction during echocardiography and specified anatomical characteristics of aneurysm during computer tomography. There was no evidence of obstructive coronary artery disease during coronary angiography. Taking into consideration multiple cerebral infarcts, aneurysm resection and left ventricular plastics was performed. Electronic microscopy of myocardium confirmed the diagnosis of hypertrophic cardiomyopathy.

  4. Upgrading primary heat transport pump seals

    International Nuclear Information System (INIS)

    Graham, T.; Metcalfe, R.; Rhodes, D.; McInnes, D.

    1995-01-01

    Changes in the operating environment at the Bruce-A Nuclear Generating Station created the need for an upgraded Primary Heat Transport Pump (PHTP) seal. In particular, the requirement for low pressure running during more frequent start-ups exposed a weakness of the CAN2 seal and reduced its reliability. The primary concern at Bruce-A was the rotation of the CAN2 No. 2 stators in their holders. The introduction of low pressure running exacerbated this problem, giving rapid wear of the stator back face, overheating, and thermocracking. In addition, the resulting increase in friction between the stator and its holder increased stationary-side hysteresis and thereby changed the seal characteristic to the point where interseal pressure oscillations became prevalent. The resultant increased hysteresis also led to hard rubbing of the seal faces during temperature transients. An upgraded seal was required for improved reliability to avoid forced outages and to reduce maintenance costs. This paper describes this upgraded 'replacement seal' and its performance history. In spite of the 'teething' problems detailed in this paper, there have been no forced outages due to the replacement seal, and in the words of a seal maintenance worker at Bruce-A, 'it allows me to go home and sleep at night instead of worrying about seal failures.' (author)

  5. Advanced High Temperature Structural Seals

    Science.gov (United States)

    Newquist, Charles W.; Verzemnieks, Juris; Keller, Peter C.; Rorabaugh, Michael; Shorey, Mark

    2002-10-01

    This program addresses the development of high temperature structural seals for control surfaces for a new generation of small reusable launch vehicles. Successful development will contribute significantly to the mission goal of reducing launch cost for small, 200 to 300 pound payloads. Development of high temperature seals is mission enabling. For instance, ineffective control surface seals can result in high temperature (3100 F) flows in the elevon area exceeding structural material limits. Longer sealing life will allow use for many missions before replacement, contributing to the reduction of hardware, operation and launch costs.

  6. Upgrading inflatable door seals

    International Nuclear Information System (INIS)

    Sykes, T.M.; Metcalfe, R.; Welch, L.A.; Josefowich, J.M.

    1997-01-01

    Inflatable door seals are used for airlocks in CANDU stations. They have been a significant source of unreliability and maintenance cost. A program is underway to improve their performance and reliability, backed by environmental qualification testing. Only commercial products and suppliers existed in 1993. For historical reasons, these 'existing products' did not use the most durable material then available. In hindsight, neither had they been adapted nor optimized to combat conditions often experienced in the plants-sagging doors, damaged sealing surfaces, and many thousands of openings and closings per year. Initial attempts to involve the two existing suppliers in efforts to upgrade these seals were unsuccessful. Another suitable supplier had therefore to be found, and a 'new,' COG-owned seal developed; this was completed in 1997. This paper summarizes its testing, along with that of the two existing products. Resistance to aging has been improved significantly. Testing has shown that an accident can be safely withstood after 10 years of service or 40,000 openings-closings, whichever comes first. AECL's Fluid Sealing Technology Unit (FSTU) has invested in the special moulds, test fixtures and other necessary tooling and documentation required to begin commercial manufacture of this new quality product. Accordingly, as with FSTU's other nuclear products such as pump seals, the long-term supply of door seals to CANDU plants is now protected from many external uncertainties-e.g., commercial products being discontinued, materials being changed, companies going out of business. Manufacturing to AECL's detailed specifications is being subcontracted to the new supplier. FSTU is performing the quality surveillance, inspection, testing, and customer service activities concomitant with direct responsibility for supply to the plants. (author)

  7. Fiber Optic Safeguards Sealing System

    Science.gov (United States)

    1978-01-01

    8217 or trade names does not constitute an official indorsement or approval of the use thereof. Destroy this report when it is no longer needed. Do not...an intergrity check of a seal than to photograph the seal’s fingerprints and to match positive/negative overlays. The seal identification time and

  8. Assessment of Root Morphology and Apices of First and Second Maxillary Molars in Tehran Population

    Directory of Open Access Journals (Sweden)

    Mandana Naseri

    2015-12-01

    Full Text Available Introduction: Objective: This study aimed to assess the possible variations in root canal anatomy and topography of the apices of first and second maxillary molars. Materials and methods: A total of 67 first and second maxillary permanent molars were collected. Access cavity was prepared and 2% methylene blue was injected. The teeth were demineralized by 5% nitric acid and cleared with methyl salicylate. Specimens were evaluated under stereomicroscopy and analyzed using the sample t-test. Results: Based on Vertucci’s classification, the mesiobuccal root of maxillary first molars was type I in 87.5% and type IV in 12.5% of the cases. The mesiobuccal root of second maxillary molars was type I in 60%, type II in 8.6%, type IV in 25.7% and type V in 5.7% of cases. In maxillary first and second molars, the distobuccal and palatal roots were type I in 100% of the cases. The distance of the apical constriction from the apical foramen was 0.21±0.09 mm, the distance from the apical constriction tothe anatomic apex was 0.44±0.19 mm and the distance of the apical foramen from the anatomic apex was 0.15±0.15 mm. The mean percentage of delta prevalence was 3.2% in both teeth. Conclusion: The mean distance of the apical foramen and apical constriction from the anatomic apex was less than 0.6 and 1.2 mm, respectively. In maxillary first and second molars, the mean distance of the apical constriction from the apical foramen and anatomic apex was 0.21 and 0.44, respectively and the mean distance of the apical foramen from the anatomic apex was 0.15 mm

  9. Turbine Seal Research at NASA GRC

    Science.gov (United States)

    Proctor, Margaret P.; Steinetz, Bruce M.; Delgado, Irebert R.; Hendricks, Robert C.

    2011-01-01

    Low-leakage, long-life turbomachinery seals are important to both Space and Aeronautics Missions. (1) Increased payload capability (2) Decreased specific fuel consumption and emissions (3) Decreased direct operating costs. NASA GRC has a history of significant accomplishments and collaboration with industry and academia in seals research. NASA's unique, state-of-the-art High Temperature, High Speed Turbine Seal Test Facility is an asset to the U.S. Engine / Seal Community. Current focus is on developing experimentally validated compliant, non-contacting, high temperature seal designs, analysis, and design methodologies to enable commercialization.

  10. Enhanced sealing project (ESP): design, construction and monitoring of a full-scale shaft seal

    International Nuclear Information System (INIS)

    Dixon, D.; Martino, J.; Kim, C.S.; Holowick, B.; Kwong, G.; Jonsson, E.; Palonen, E.; DeCombarieu, M.

    2010-01-01

    Document available in extended abstract form only. The Enhanced Sealing Project (ESP) consists of instrumenting and monitoring a full-scale shaft seal installed to permanently close the access shaft for Atomic Energy of Canada Limited's (AECL's) Underground Research Laboratory (URL) at the intersection of an ancient low dipping thrust fault. The URL was built to provide a facility where concepts for long-term management of Canada's nuclear fuel waste in a deep geological repository could be studied. Operated since the early 1980's, this facility provided much of the technical information used in developing the deep geological repository concept submitted by AECL to the Government of Canada in 1994 and continued to provide valuable technical data after that submission. In 2003, a decision was made to discontinue operation of the URL and ultimately decommission and permanently close the underground portion of this facility. As part of the Nuclear Legacy Liability Program (NLLP) being funded by Natural Resources Canada (NRCan), facilities including the URL that are no longer part of AECL's mandate or operations are being decommissioned. Included in this work is the installation of seals at the intersection of the access shaft and ventilation raise with a deep fracture zone in order to limit the potential for mixing of deeper saline and shallower less saline groundwater. The funding available from NRCan was limited to the seal installation, with no mandate to provide any more than basic hydrological monitoring of the rock mass at a considerable distance from these seals, and so the opportunity to monitor a full-scale shaft seal similar to one for a deep geological repository would have been lost. The ESP arose from the recognition by a number of organizations that the URL closure presented a unique opportunity to monitor the evolution of a full-scale repository-type shaft seal in a very well-characterized and otherwise undisturbed rock mass. As

  11. Sealed can of spent fuel

    International Nuclear Information System (INIS)

    Suzuki, Yasuyuki.

    1976-01-01

    Object: To provide a seal plug cover with a gripping portion fitted to a canning machine and a gripping portion fitted to a gripper of the same configuration as a fuel body for handling the fuel body so as to facilitate the handling work. Structure: A sealed can comprises a vessel and a seal plug cover, said cover being substantially in the form of a bottomed cylinder, which is slipped on the vessel and air-tightly secured by a fastening bolt between it and a flange. The spent fuel body is received into the vessel together with coolant during the step of canning operation. Said seal plug cover has two gripping portions, one for opening and closing the plug cover of the canning machine as an exclusive use member, the other being in the form of a hook-shaped peripheral groove, whereby the gripping portions may be effectively used using the same gripper when the spent fuel body is transported while being received in the sealed can or when the fuel body is removed from the sealed can. (Kawakami, Y.)

  12. Detection and direction discrimination of single vortex rings by harbour seals (Phoca vitulina).

    Science.gov (United States)

    Krüger, Yvonne; Hanke, Wolf; Miersch, Lars; Dehnhardt, Guido

    2018-04-25

    Harbour seals possess highly sensitive vibrissae that enable them to track hydrodynamic trails left behind by a swimming fish. Most of these trails contain vortex rings as a main hydrodynamic component. They may reveal information about their generator as the trails differ depending on the fish species, the fish's body shape, size and swimming style. In addition, fish generate single vortex rings in diverse natural situations. In this study, the ability of blindfolded stationary harbour seals to detect and analyse single vortex rings regarding directional information has been investigated. In three different behavioural experiments, the animals were trained to respond to single artificially generated vortex rings. The results show that harbour seals are able to respond to a variety of different vortex rings upon vibrissal stimulation. The investigation of the minimum hydrodynamically perceivable angle revealed that it is at least as small as 5.7 deg, which was the smallest adjustable angle. Moreover, harbour seals are capable of analysing the travel direction of a vortex ring perceived by the mystacial vibrissae irrespective of whether the vibrissae were stimulated ipsilaterally or contralaterally. In situations in which no complex hydrodynamic trail is available, it is advantageous for a hunting seal to be able to extract information from a single vortex ring. © 2018. Published by The Company of Biologists Ltd.

  13. Deep-apical tubules: dynamic lipid-raft microdomains in the brush-border region of enterocytes

    DEFF Research Database (Denmark)

    Hansen, Gert H; Pedersen, Jens; Niels-Christiansen, Lise-Lotte

    2003-01-01

    microdomains. Deep-apical tubules were positioned close to the actin rootlets of adjacent microvilli in the terminal web region, which had a diameter of 50-100 nm, and penetrated up to 1 microm into the cytoplasm. Markers for transcytosis, IgA and the polymeric immunoglobulin receptor, as well as the resident...... lipid raft-containing compartments, but little is otherwise known about these raft microdomains. We therefore studied in closer detail apical lipid-raft compartments in enterocytes by immunogold electron microscopy and biochemical analyses. Novel membrane structures, deep-apical tubules, were visualized...... brush-border enzyme aminopeptidase N, were present in these deep-apical tubules. We propose that deep-apical tubules are a specialized lipid-raft microdomain in the brush-border region functioning as a hub in membrane trafficking at the brush border. In addition, the sensitivity to cholesterol depletion...

  14. Field Test and Evaluation of Engineered Biomineralization Technology for Sealing Existing Wells

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Alfred [Montana State Univ., Bozeman, MT (United States)

    2015-12-21

    This research project addresses one of the goals of the U.S. Department of Energy (DOE) Carbon Storage Program (CSP) aimed at developing Advanced Wellbore Integrity Technologies to Ensure Permanent Geologic Carbon Storage. The technology field-tested in this research project is referred to as microbially induced calcite precipitation (MICP), which utilizes a biologically-based process to precipitate calcium carbonate. If properly controlled MICP can successfully seal fractures, high permeability zones, and compromised wellbore cement in the vicinity of wellbores and in nearby caprock, thereby improving the storage security of geologically-stored carbon dioxide. This report describes an MICP sealing field test performed on a 24.4 cm (9.625 inch) diameter well located on the Gorgas Steam Generation facility near Jasper, Alabama. The research was aimed at (1) developing methods for delivering MICP promoting fluids downhole using conventional oil field technologies and (2) assessing the ability of MICP to seal cement and formation fractures in the near wellbore region in a sandstone formation. Both objectives were accomplished successfully during a field test performed during the period April 1-11, 2014. The test resulted in complete biomineralization sealing of a horizontal fracture located 340.7 m (1118 feet) below ground surface. A total of 24 calcium injections and six microbial inoculation injections were required over a three day period in order to achieve complete sealing. The fractured region was considered completely sealed when it was no longer possible to inject fluids into the formation without exceeding the initial formation fracture pressure. The test was accomplished using conventional oil field technology including an 11.4 L (3.0 gallon) wireline dump bailer for injecting the biomineralization materials downhole. Metrics indicating successful MICP sealing included reduced injectivity during seal formation, reduction in pressure falloff, and

  15. Insecurity of imperfect quantum bit seal

    International Nuclear Information System (INIS)

    Chau, H.F.

    2006-01-01

    Quantum bit seal is a way to encode a classical bit quantum mechanically so that everyone can obtain non-zero information on the value of the bit. Moreover, such an attempt should have a high chance of being detected by an authorized verifier. Surely, a reader looks for a way to get the maximum amount of information on the sealed bit and at the same time to minimize her chance of being caught. And a verifier picks a sealing scheme that maximizes his chance of detecting any measurement of the sealed bit. Here, I report a strategy that passes all measurement detection procedures at least half of the time for all quantum bit sealing schemes. This strategy also minimizes a reader's chance of being caught under a certain scheme. In this way, I extend the result of Bechmann-Pasquinucci et al. by proving that quantum seal is insecure in the case of imperfect sealed bit recovery

  16. Ultrasonic dip seal maintenance system

    International Nuclear Information System (INIS)

    Poindexter, A.M.; Ricks, H.E.

    1978-01-01

    Disclosed is a system for removing impurities from the surfaces of liquid dip seals and for wetting the metal surfaces of liquid dip seals in nuclear components. The system comprises an ultrasonic transducer that transmits ultrasonic vibrations along an ultrasonic probe to the metal and liquid surfaces of the dip seal thereby loosening and removing those impurities

  17. Reusable tamper-indicating security seal

    International Nuclear Information System (INIS)

    Ryan, M.J.

    1981-01-01

    A reusable tamper-indicating mechanical security seal for use in safeguarding nuclear material has been developed. The high-security seal displays an unpredictable, randomly selected, five-digit code each time it is used. This five digit code serves the same purpose that the serial number does for conventional non-reusable seals - a unique identifier for each use or application. The newly developed reusable seal is completely enclosed within a seamless, tamper-indicating, plastic jacket. The jacket is designed to reveal any attempts to penetrate, section or to chemically remove and replace with a counterfeit for surreptitious purposes

  18. Actively controlled shaft seals for aerospace applications

    Science.gov (United States)

    Salant, Richard F.

    1995-07-01

    This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with a piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changes suddenly. the experimental results were compared to the predictions from the mathematical model. The model was successful in predicting the trends in leakage rate that occurred as the balance ratio and sealed pressure changed

  19. Aminopeptidase N is directly sorted to the apical domain in MDCK cells

    DEFF Research Database (Denmark)

    Wessels, H P; Hansen, Gert Helge; Fuhrer, C

    1990-01-01

    In different epithelial cell types, integral membrane proteins appear to follow different sorting pathways to the apical surface. In hepatocytes, several apical proteins were shown to be transported there indirectly via the basolateral membrane, whereas in MDCK cells a direct sorting pathway from...

  20. Pool gateway seal

    International Nuclear Information System (INIS)

    Starr, J.A.; Steinert, L.A.

    1983-01-01

    A device for sealing a gateway between interconnectable pools in a nuclear facility comprising a frame supporting a liquid impermeable sheet positioned in a u-shaped gateway between the pools. An inflatable tube carried in a channel in the periphery of the frame and adjoining the gateway provides a seal therebetween when inflated. A restraining arrangement on the bottom edge of the frame is releasably engagable with an adjacent portion of the gateway to restrict the movement of the frame in the u-shaped gateway upon inflation of the tube, thereby enhancing the seal. The impermeable sheet is formed of an elastomer and thus is conformable to a liquid permeable supportive wall upon application of liquid pressure to the side of the sheet opposite the wall

  1. Development and high temperature sealing performance study of double sealing flange

    International Nuclear Information System (INIS)

    Zhang Qinhua; Fu Yuan; Xie Leidong; Li Zhong; Tang Zhongfeng

    2013-01-01

    Background: Flange is an important component used in the connection between pipes or between pipe and equipment. It is widely used in mechanical industry, petrochemical industry and nuclear industry. Ordinary flange could be oxidized oi corroded under high temperature and strong corrosion condition, which leads to flange's failure. Purpose: The aim is to design and validate the double sealing flange which could be used in high temperature and strong corrosion condition stably and supplied as a reliable detachable connection for petrochemical industry and nuclear industry under high temperature and strong corrosion environment. Methods: New flange is designed using flexible graphite spiral wound gaskets and C style metal ring double sealing structure. The unique protection gas design ensures the graphite spiral wound gasket used in high temperature reliably. Test bed is built to verify the stability of the flange. Results: Pressure reducing of graphite spiral wound gasket is only 0.01 MPa at 750℃, 0.7 MPa for 43 h, there is not obvious oxidation phenomenon at the same time. The leakage rate of metal C sealing ring is 11.51×10 -4 atm cc/s, and the metal C ring sealing's performance meets the engineering requirements. Conclusion: The leakage rate of double sealing flange is almost zero under 0.7 MPa at 750℃, which meets the engineering requirements. It avoids oxidizing at high temperature and corroding under strong corrosion condition. (authors)

  2. Steam Turbine Flow Path Seals (a Review)

    Science.gov (United States)

    Neuimin, V. M.

    2018-03-01

    Various types of shroud, diaphragm, and end seals preventing idle leak of working steam are installed in the flow paths of steam turbine cylinders for improving their efficiency. Widely known labyrinth seals are most extensively used in the Russian turbine construction industry. The category of labyrinth seals also includes seals with honeycomb inserts. The developers of seals with honeycomb inserts state that the use of such seals makes it possible to achieve certain gain due to smaller leaks of working fluid and more reliable operation of the system under the conditions in which the rotor rotating parts may rub against the stator elements. However, a positive effect can only be achieved if the optimal design parameters of the honeycomb structure are fulfilled with due regard to the specific features of its manufacturing technology and provided that this structure is applied in a goal-seeking manner in the seals of steam and gas turbines and compressors without degrading their vibration stability. Calculated and preliminary assessments made by experts testify that the replacement of conventional labyrinth seals by seals with honeycomb inserts alone, due to which the radial gaps in the shroud seal can be decreased from 1.5 to 0.5 mm, allows the turbine cylinder efficiency to be increased at the initial stage by approximately 1% with the corresponding gain in the turbine set power output. The use of rectangular-cellular seals may result, according to estimates made by their developers, in a further improvement of turbine efficiency by 0.5-1.0%. The labor input required to fabricate such seals is six to eight times smaller than that to fabricate labyrinth seals with honeycomb inserts. Recent years have seen the turbine construction companies of the United States and Germany advertising the use of abradable (sealing) coatings (borrowed from the gas turbine construction technology) in the turbine designs instead of labyrinth seals. The most efficient performance of

  3. Prognostic factors in apical surgery with root-end filling: a meta-analysis

    DEFF Research Database (Denmark)

    von Arx, Thomas; Peñarrocha, Miguel; Jensen, Simon Storgård

    2010-01-01

    Apical surgery has seen continuous development with regard to equipment and surgical technique. However, there is still a shortage of evidence-based information regarding healing determinants. The objective of this meta-analysis was to review clinical articles on apical surgery with root-end fill...

  4. High efficiency algorithm for 3D transient thermo-elasto-plastic contact problem in reactor pressure vessel sealing system

    International Nuclear Information System (INIS)

    Xu Mingyu; Lin Tengjiao; Li Runfang; Du Xuesong; Li Shuian; Yang Yu

    2005-01-01

    There are some complex operating cases such as high temperature and high pressure during the operating process of nuclear reactor pressure vessel. It is necessary to carry out mechanical analysis and experimental investigation for its sealing ability. On the basis of the self-developed program for 3-D transient sealing analysis for nuclear reactor pressure vessel, some specific measures are presented to enhance the calculation efficiency in several aspects such as the non-linear solution of elasto-plastic problem, the mixed solution algorithm for contact problem as well as contract heat transfer problem and linear equation set solver. The 3-D transient sealing analysis program is amended and complemented, with which the sealing analysis result of the pressure vessel model can be obtained. The calculation results have good regularity and the calculation efficiency is twice more than before. (authors)

  5. Hydrodynamic discrimination of wakes caused by objects of different size or shape in a harbour seal (Phoca vitulina)

    DEFF Research Database (Denmark)

    Wieskotten, S.; Mauck, B.; Miersch, L.

    2011-01-01

    Harbour seals can use their mystacial vibrissae to detect and track hydrodynamic wakes. We investigated the ability of a harbour seal to discriminate objects of different size or shape by their hydrodynamic signature and used particle image velocimetry to identify the hydrodynamic parameters...... that a seal may be using to do so. Hydrodynamic trails were generated by different sized or shaped paddles that were moved in the calm water of an experimental box to produce a characteristic signal. In a two-alternative forced-choice procedure the blindfolded subject was able to discriminate size differences...... of down to 3.6. cm (Weber fraction 0.6) when paddles were moved at the same speed. Furthermore the subject distinguished hydrodynamic signals generated by flat, cylindrical, triangular or undulated paddles of the same width. Particle image velocimetry measurements demonstrated that the seal could have...

  6. Intraoperative cervix location and apical support stiffness in women with and without pelvic organ prolapse.

    Science.gov (United States)

    Swenson, Carolyn W; Smith, Tovia M; Luo, Jiajia; Kolenic, Giselle E; Ashton-Miller, James A; DeLancey, John O

    2017-02-01

    It is unknown how initial cervix location and cervical support resistance to traction, which we term "apical support stiffness," compare in women with different patterns of pelvic organ support. Defining a normal range of apical support stiffness is important to better understand the pathophysiology of apical support loss. The aims of our study were to determine whether: (1) women with normal apical support on clinic Pelvic Organ Prolapse Quantification, but with vaginal wall prolapse (cystocele and/or rectocele), have the same intraoperative cervix location and apical support stiffness as women with normal pelvic support; and (2) all women with apical prolapse have abnormal intraoperative cervix location and apical support stiffness. A third objective was to identify clinical and biomechanical factors independently associated with clinic Pelvic Organ Prolapse Quantification point C. We conducted an observational study of women with a full spectrum of pelvic organ support scheduled to undergo gynecologic surgery. All women underwent a preoperative clinic examination, including Pelvic Organ Prolapse Quantification. Cervix starting location and the resistance (stiffness) of its supports to being moved steadily in the direction of a traction force that increased from 0-18 N was measured intraoperatively using a computer-controlled servoactuator device. Women were divided into 3 groups for analysis according to their pelvic support as classified using the clinic Pelvic Organ Prolapse Quantification: (1) "normal/normal" was women with normal apical (C -5 cm and Ba and/or Bp ≥ 0 cm). Demographics, intraoperative cervix locations, and apical support stiffness values were then compared. Normal range of cervix location during clinic examination and operative testing was defined by the total range of values observed in the normal/normal group. The proportion of women in each group with cervix locations within and outside the normal range was determined. Linear regression

  7. SEAL FOR HIGH SPEED CENTRIFUGE

    Science.gov (United States)

    Skarstrom, C.W.

    1957-12-17

    A seal is described for a high speed centrifuge wherein the centrifugal force of rotation acts on the gasket to form a tight seal. The cylindrical rotating bowl of the centrifuge contains a closure member resting on a shoulder in the bowl wall having a lower surface containing bands of gasket material, parallel and adjacent to the cylinder wall. As the centrifuge speed increases, centrifugal force acts on the bands of gasket material forcing them in to a sealing contact against the cylinder wall. This arrangememt forms a simple and effective seal for high speed centrifuges, replacing more costly methods such as welding a closure in place.

  8. The apical complex provides a regulated gateway for secretion of invasion factors in Toxoplasma.

    Directory of Open Access Journals (Sweden)

    Nicholas J Katris

    2014-04-01

    Full Text Available The apical complex is the definitive cell structure of phylum Apicomplexa, and is the focus of the events of host cell penetration and the establishment of intracellular parasitism. Despite the importance of this structure, its molecular composition is relatively poorly known and few studies have experimentally tested its functions. We have characterized a novel Toxoplasma gondii protein, RNG2, that is located at the apical polar ring--the common structural element of apical complexes. During cell division, RNG2 is first recruited to centrosomes immediately after their duplication, confirming that assembly of the new apical complex commences as one of the earliest events of cell replication. RNG2 subsequently forms a ring, with the carboxy- and amino-termini anchored to the apical polar ring and mobile conoid, respectively, linking these two structures. Super-resolution microscopy resolves these two termini, and reveals that RNG2 orientation flips during invasion when the conoid is extruded. Inducible knockdown of RNG2 strongly inhibits host cell invasion. Consistent with this, secretion of micronemes is prevented in the absence of RNG2. This block, however, can be fully or partially overcome by exogenous stimulation of calcium or cGMP signaling pathways, respectively, implicating the apical complex directly in these signaling events. RNG2 demonstrates for the first time a role for the apical complex in controlling secretion of invasion factors in this important group of parasites.

  9. The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps.

    Science.gov (United States)

    Yamazaki, K; Mori, T; Tomioka, J; Litwak, P; Antaki, J F; Tagusari, O; Koyanagi, H; Griffith, B P; Kormos, R L

    1997-01-01

    A critical issue facing the development of an implantable, rotary blood pump is the maintenance of an effective seal at the rotating shaft. Mechanical seals are the most versatile type of seal in wide industrial applications. However, in a rotary blood pump, typical seal life is much shorter than required for chronic support. Seal failure is related to adhesion and aggregation of heat denatured blood proteins that diffuse into the lubricating film between seal faces. Among the blood proteins, fibrinogen plays an important role due to its strong propensity for adhesion and low transition temperature (approximately 50 degrees C). Once exposed to temperature exceeding 50 degrees C, fibrinogen molecules fuse together by multi-attachment between heat denatured D-domains. This quasi-polymerized fibrin increases the frictional heat, which proliferates the process into seal failure. If the temperature of the seal faces is maintained well below 50 degrees C, a mechanical seal would not fail in blood. Based on this "Cool-Seal" concept, we developed a miniature mechanical seal made of highly thermally conductive material (SiC), combined with a recirculating purge system. A large supply of purge fluid is recirculated behind the seal face to augment convective heat transfer to maintain the seal temperature below 40 degrees C. It also cools all heat generating pump parts (motor coil, bearing, seal). The purge consumption has been optimized to virtually nil (seal system has now been incorporated into our intraventricular axial flow blood pump (IVAP) and newly designed centrifugal pump. Ongoing in vivo evaluation of these systems has demonstrated good seal integrity for more than 160 days. The Cool-Seal system can be applied to any type of rotary blood pump (axial, diagonal, centrifugal, etc.) and offers a practical solution to the shaft seal problem and heat related complications, which currently limit the use of implantable rotary blood pumps.

  10. Evaluation and Comparison of the Position of the Apical Constriction in Single-root and Multiple-root Teeth

    Directory of Open Access Journals (Sweden)

    Alireza Farhad

    2017-12-01

    Full Text Available Introduction: Precise knowledge of the location of the apical constriction is essential to root canal treatment and long-term prognosis. Considering the differences in the apical constriction and size of the roots in single- and multiple-root teeth in various races, examination and comparison of the location of the apical constriction in single-root and multiple-root teeth are of paramount importance. The present studies aimed to measure and compare the distance of the apical constriction from the apical foramen and anatomical apex in single-root and multiple-root teeth. Materials and Methods: In this cross-sectional study, 60 roots of single-rooted teeth and 60 roots of multiple-rooted teeth were collected from the patients referring to the health centers in Isfahan, Iran. After cleansing and disinfecting the surface of the roots, the surface of the teeth was washed with hypochlorite. Based on the direction of the apical foramen, a longitudinal cut was made in the same direction, and the roots were examined microscopically at the magnification of 25. Following that, the distance of the apical constriction from the apical foramen and anatomical apex was measured using a digital camera. In addition, mean and standard deviation of the obtained distance values were determined. Distances in the single-root and multiple-root teeth were compared using independent t-test, at the significance level of Results: Mean distance between the apical constriction and apical foramen was 0.86±0.33 mm in the single-root teeth and 0.072±0.27 mm in the multiple-root teeth. Mean distance between the apical constriction and anatomical apex was 1.14±0.36 mm in the single-root teeth and 1.03±0.36 mm in the multiple-root teeth. Moreover, the results of independent t-test showed the distance of the apical constriction from the apical foramen to be significant between single-root and multiple-rooted teeth (P=0.013. However, the distance between the apical constriction

  11. Left ventricular apical ballooning syndrome

    International Nuclear Information System (INIS)

    Rahman, N.; Tai, J.; Soofi, A.

    2007-01-01

    The transient left ventricular apical ballooning syndrome, also known as Takotsubo cardiomyopathy, is characterized by transient left ventricular dysfunction in the absence of obstructive epicardial coronary disease. Although the syndrome has been reported in Japan since 1990, it is rare in other regions. Rapid recognition of the syndrome can modify the diagnostic and therapeutic attitude i.e. avoiding thrombolysis and performing catheterization in the acute phase. (author)

  12. A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals

    Directory of Open Access Journals (Sweden)

    Young-Sil Yoo

    2011-11-01

    Full Text Available Objectives The study was to compare the shaping ability of Reciproc (VDW and WaveOne (Dentsply Maillefer instruments compared with ProTaper, Profile and hand instrument during the preparation of simulated root canals. Materials and Methods Five groups (n = 5 were established. Reciproc, WaveOne, ProTaper, Profile and K file (K-flexo file were used to prepare the resin simulated canals. A series of preoperative and postoperative images were taken by a microscope and superimposed in 2 different layers. The amount of resin removed from both the inner and the outer sides of the canal was measured to the level of 10 mm from the apical tip, with a 1 mm increment. Results The mean of resin removal from the inner canal wall was not different from the outer canal wall for Reciproc and WaveOne groups at apical third (1 - 3 mm level. There was no difference in the change of working length and maintenance of canal curvature. NiTi instruments are superior to stainless-steel K file in their shaping ability. Conclusions Within the limitation of this present study, Reciproc and WaveOne instruments maintained the original canal curvature in curved canals better than ProTaper and Profile, which tend to transport towards the outer canal wall of the curve in the apical part of the canal.

  13. Morfologia e biometria do ligamento apical do pênis de touros da raça Girolando Morphology and biometry of the apical ligament of the penis of Girolando race bulls

    Directory of Open Access Journals (Sweden)

    Júlio Roquete Cardoso

    2010-08-01

    Full Text Available Objetivou-se descrever a morfologia e biometria do ligamento apical do pênis de 32 touros da raça Girolando (Bos taurus indicus X Bos taurus taurus, Linnaeus - 1758, com idade de 36 a 48 meses e pesando de 480 a 540kg. As peças anatômicas foram obtidas em frigorífico e mantidas congeladas até dissecação. O ligamento originou-se a 15,1±2,9cm distalmente à curvatura caudal da flexura sigmoide e inseriu-se a 1,4±0,7cm proximalmente ao colo da glande, medindo 18,9±2,6cm de comprimento. Apresentou largura de 1,9±0,6mm na sua origem, 2,2±0,8mm na inserção e 35,2±10mm na altura da inserção da lâmina interna do prepúcio. A espessura média ao longo de sua extensão variou de 0,7 a 1,9mm. Próximo à coroa da glande, o ligamento apical se posiciona principalmente na superfície dorsolateral esquerda desse órgão, e a característica da sua fixação na albugínea apresentou variações ao longo de sua extensão. Em sua origem e inserção e na face esquerda do pênis, o ligamento apical é firmemente aderido à túnica albugínea, mas na face dorsal e direita do pênis essa união é realizada por meio de tecido conjuntivo frouxo. Verificou-se correlação média entre o comprimento e a circunferência do pênis com o comprimento do ligamento apical, mas a correlação entre essas variáveis do pênis e a largura do ligamento apical foi baixa.The aim of this study was to describe the morphology and biometry of the apical ligament of the penis of Girolando bulls. For this purpose, it was dissected 32 penis of Girolando bulls obtained from slaughterhouses and kept frozen until their dissection. The animals were 36 to 48 month old and weighted between 480 and 540kg. The origin of the apical ligament occurred at 15.1±2.9cm distally to the caudal loop of the sigmoid flexure and its insertion occurred at 1.4±0.7cm proximally to the neck of the glans. The length of the apical ligament was 19.9±2.6cm. The width was 1.9±0.6mm at its

  14. Miniature magnetic fluid seal working in liquid environments

    Energy Technology Data Exchange (ETDEWEB)

    Mitamura, Yoshinori, E-mail: ymitamura@par.odn.ne.jp [Graduate School of Information Science and Technology, Hokkaido University, Sapporo 060-0814 (Japan); Durst, Christopher A., E-mail: chris@procyrion.com [Procyrion, Inc., Houston, TX 77027 (United States)

    2017-06-01

    This study was carried out to develop a miniature magnetic fluid (MF) seal working in a liquid environment. The miniature MF seal is intended for use in a catheter blood pump. The requirements for the MF seal included a size of less than Ø4×4.5 mm, shaft diameter of 1 mm, sealing pressure of 200 mmHg, shaft speed of up to 40000 rpm, and life of one month. The miniature MF seal was composed of an NdFeB magnet (Ø4×Ø2×1) sandwiched between two pole pieces (Ø4×Ø1.1×0.5). A shield (Ø4×Ø1.2×1.5) was placed on the pole piece facing the liquid to minimize the influence of pump flow on the MF. The seal was installed on a Ø1 shaft. A seal was formed by injecting MF (Ms: 47.8 kA/m and η: 0.5 Pa·sec) into the gap between the pole pieces and the shaft. Total volume of the MF seal was 44 μL. A sealing pressure of 370 mmHg was obtained at motor speeds of 0-40,000 rpm. The seal remained perfect for 10 days in saline under the condition of a pump flow of 1.5 L/min (The test was terminated in accordance with plans). The seal remained intact after ethylene oxide sterilization during which the seal was exposed to high pressures. In conclusion, the newly developed MF seal will be useful for a catheter pump. - Highlights: • A miniature magnetic fluid seal working in a liquid environment was developed. • The seal can be installed on Ø1 mm shaft and can seal against 370 mmHg at 40000 rpm. • The magnetic fluid seal will be useful for a catheter blood pump.

  15. Design analysis of a self-acting spiral-groove ring seal for counter-rotating shafts. [o ring seals

    Science.gov (United States)

    Dirusso, E.

    1983-01-01

    A self-acting spiral groove inter-shaft ring seal of nominal 16.33 cm (6.43 in.) diameter for sealing fan bleed air between counter rotating shafts in advanced turbofan engines was analyzed. The analysis focused on the lift force characteristics of the spiral grooves. A NASA Lewis developed computer program for predicting the performance of gas lubricated face seals was used to optimize the spiral groove geometry to produce maximum lift force. Load capacity curves (lift force as function of film thickness) were generated for four advanced turbofan engine operating conditions at relative seal speeds ranging from 17,850 to 29,800 rpm, sealed air pressures from 6 to 42 N/sq cm (9 to 60 psi) absolute and temperatures from 95 to 327 C (203 to 620 F). The relative seal sliding speed range was 152 to 255 m/sec (500 to 836 ft/sec). The analysis showed that the spiral grooves are capable of producing sufficient lift force such that the ring seal will operate in a noncontacting mode over the operating range of typical advanced turbofan engines.

  16. Seal Apparatus and Methods to Manufacture Thereof

    Science.gov (United States)

    Richard, James A. (Inventor)

    2013-01-01

    In some implementations, apparatus and methods are provided through which a dynamic cryogenic seal is manufactured. In some implementations, the seal includes a retainer and a spring-seal assembly, the assembly being comprised of a main spring housing and fluorine-containing polymer seals. In some implementations, either a radial seal, or an axial (or "piston seal") is provided. In some implementations, methods of manufacturing the dynamic cryogenic seal are also provided. In some implementations, the methods include assembling the components while either heated or cooled, taking advantage of thermal expansion and contraction, such that there is a strong interference fit between the components at room temperature. In some implementations, this process ensures that the weaker fluorine-containing polymer seal is forced to expand and contract with the stronger retainer and spring and is under constant preload. In some implementations, the fluorine-containing polymer is therefore fluidized and retained, and can not lift off.

  17. A dynamic analysis of rotary combustion engine seals

    Science.gov (United States)

    Knoll, J.; Vilmann, C. R.; Schock, H. J.; Stumpf, R. P.

    1984-01-01

    Real time work cell pressures are incorporated into a dynamic analysis of the gas sealing grid in Rotary Combustion Engines. The analysis which utilizes only first principal concepts accounts for apex seal separation from the crochoidal bore, apex seal shifting between the sides of its restraining channel, and apex seal rotation within the restraining channel. The results predict that apex seals do separate from the trochoidal bore and shift between the sides of their channels. The results also show that these two motions are regularly initiated by a seal rotation. The predicted motion of the apex seals compares favorably with experimental results. Frictional losses associated with the sealing grid are also calculated and compare well with measurements obtained in a similar engine. A comparison of frictional losses when using steel and carbon apex seals has also been made as well as friction losses for single and dual side sealing.

  18. Mechanical seal having a double-tier mating ring

    Science.gov (United States)

    Khonsari, Michael M.; Somanchi, Anoop K.

    2005-09-13

    An apparatus and method to enhance the overall performance of mechanical seals in one of the following ways: by reducing seal face wear, by reducing the contact surface temperature, or by increasing the life span of mechanical seals. The apparatus is a mechanical seal (e.g., single mechanical seals, double mechanical seals, tandem mechanical seals, bellows, pusher mechanical seals, and all types of rotating and reciprocating machines) comprising a rotating ring and a double-tier mating ring. In a preferred embodiment, the double-tier mating ring comprises a first and a second stationary ring that together form an agitation-inducing, guided flow channel to allow for the removal of heat generated at the seal face of the mating ring by channeling a coolant entering the mating ring to a position adjacent to and in close proximity with the interior surface area of the seal face of the mating ring.

  19. A lesão apical em cardiopatas chagásicos crônicos: estudo necroscópico Apical lesions in Chagas' heart disease patients: an autopsy study

    Directory of Open Access Journals (Sweden)

    Cristina Brandt Friedrich Martin Gurgel

    2010-12-01

    Full Text Available INTRODUÇÃO: A lesão apical ventricular é típica da cardiopatia chagásica e sua presença representa risco de fenômenos tromboembólicos. O objetivo deste trabalho é avaliar a frequência de LA à necropsia de portadores de cardiopatia chagásica crônica. MÉTODOS: Análise retrospectiva de necropsias de chagásicos maiores que 17 anos. Efetuada análise estatística comparativa das variáveis clínicas e dos achados necroscópicos entre o grupo A (com lesão apical e o grupo B (ausência de lesão apical. RESULTADOS: Estudados 51 casos: 25 no grupo A (idade média de 53 anos, 64% do sexo masculinoe 26 no B.. A LA localizava-se no ventrículo esquerdo em 80% casos. No grupo B, a média de idade foi de 56 anos e 46,1% eram do sexo masculino. A forma clínica prevalente nos dois grupos foi a miopática, mas arritmia cardíaca também esteve presente em ambos (57,9% no grupo A e 32,1% no B. Foi constatada a presença de trombos em 60% dos casos do grupo A (53,3% localizados na LA e 30,7% no B; CONCLUSÕES: Houve predomínio da forma miopática nos casos com LA, com média de peso cardíaco maior em relação ao B. Em ambos os grupos observamos relação diretamente proporcional entre maior peso cardíaco e presença de tromboses. Houve predomínio do número de tromboses no grupo A, mais de 50% eram localizadas na lesão, cujo diferencial clínico principal consistiu na presença maior de arritmias. A miopatia (com aumento de peso acima de 500g foi primordial para aparecimento de tromboses.INTRODUCTION: The presence of an apical ventricular lesion increases the risk of intracardiac thrombosis and thromboembolic phenomena. The study evaluated the incidence of apical lesions and intracardiac thrombosis in Chagas' heart disease patients at autopsy. METHODS: A retrospective review of autopsies of Chagas' heart disease patients was conducted. Statistical analysis included comparison of clinical variables and autopsy findings between two groups

  20. Development of the seal for nuclear material

    International Nuclear Information System (INIS)

    Lu Feng; Lu Zhao; Zhao Yonggang; Zhang Qixin; Xiao Xuefu

    2000-01-01

    Two kinds of double cap metallic seal and an adhesive seal are developed for the purpose of the accounting for and control of nuclear material. Two kinds of double cap metallic seal are made of stainless steel and copper, respectively and the self-locked technique is used. The number and the random pattern are carved out side and in side of a cap, respectively, for the seal. The random pattern carved inside of a cap for seal is taken a picture using numeral camera and memorized in computer. Special software is developed for verification of the random pattern memorized in computer. The adhesive seal is made of special adhesive paper for purpose of security, and a special pattern guarded against falsification is printed on seal paper using ultraviolet fluorescent light technique

  1. Innovation to reality for improved pump seal performance

    International Nuclear Information System (INIS)

    Wong, W.; Eyvindson, A.; Rhodes, D.B.

    2003-01-01

    'Full-Text:' The nuclear industry requires reliable pump seals. Extended operating conditions for aging plants (i.e., low pressure starts, pressure and temperature transients) and increasing demands from new plants (larger sizes, higher speeds) are pushing the operating envelope for seals. This means that many seals that were previously considered adequate are now requiring increased attention and care. Operating utilities have taken different approaches to addressing their existing, or emerging, seal problems. Primary concerns include maintenance practices, seal design, and monitoring capabilities, as well as operating conditions, transients, pump and motor design. Success in this area requires ongoing dialogue among the station operators, pump manufacturers and seal designers. Regardless of the design, the basic requirement in CANDU is a reliable seal lifetime exceeding 5 years. This paper describes AECL's efforts to meet this requirement through an ongoing program of research and development in seal technology. Current work includes rigorous testing and evaluation of new seal materials and coatings to maximize seal stability and minimize friction and wear (i.e., pressure/temperature transients produce unpredictable shaft movement that can significantly alter face deflections affecting leak rates and seal stability, and sometimes cause the seal to hang-up and de-stage). Also required is a practical method for on-line monitoring of the condition of the seal, whether it is newly installed or after several years of reliable performance. This provides crucial information for inventory, maintenance and outage planning. While new concepts may look good on paper, it is only after they have been demonstrated under fully representative station operating conditions that they can truly be considered ready for field use. AECL CAN-seals lead the nuclear industry in reliability and seal life. They effectively save operators millions of dollars in outage time and person

  2. Assessment of apical periodontitis by MRI. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Geibel, M.A. [Ulm Univ. (Germany). Oral and Maxillofacial Surgery; Schreiber, E.S.; Bracher, A.K.; Rasche, V. [Ulm Univ. (Germany). Internal Medicine II; Hell, E.; Ulrici, J. [Sirona Dental Systems GmbH, Bensheim (Germany). Dental Imaging; Sailer, L.K. [DOC Praxisklinik im Wiley, Neu-Ulm (Germany). MKG; Ozpeynirci, Y. [Ulm Univ. (Germany). Diagnostic and Interventional Radiology

    2015-04-15

    The purpose of this clinical feasibility study was to evaluate the applicability of magnetic resonance imaging (MRI) for the assessment of apical periodontitis in direct comparison with cone beam CT (CBCT). 19 consecutive patients (average age 43 ± 13 years) with 34 lesions in total (13 molars, 14 premolars and 7 front teeth) were enrolled in this feasibility study. Periapical lesions were defined as periapical radiolucencies (CBCT) or structural changes in the spongy bone signal (MRI), which were connected with the apical part of a root and with at least twice the width of the periodontal ligament space. The location and dimension of the lesions were compared between MRI and CBCT. While mainly mineralized tissue components such as teeth and bone were visible with CBCT, complimentary information of the soft tissue components was assessable with MRI. The MRI images provided sufficient diagnostic detail for the assessment of the main structures of interest. Heterogeneous contrast was observed within the lesion, with often a clear enhancement close to the apical foramen and the periodontal gap. No difference for lesion visibility was observed between MRI and CBCT. The lesion dimensions corresponded well, but were slightly but significantly overestimated with MRI. A heterogeneous lesion appearance was observed in several patients. Four patients presented with a well circumscribed hyperintense signal in the vicinity of the apical foramen. The MRI capability of soft tissue characterization may facilitate detailed analysis of periapical lesions. This clinical study confirms the applicability of multi-contrast MRI for the identification of periapical lesions.

  3. Assessment of apical periodontitis by MRI. A feasibility study

    International Nuclear Information System (INIS)

    Geibel, M.A.; Schreiber, E.S.; Bracher, A.K.; Rasche, V.; Hell, E.; Ulrici, J.; Sailer, L.K.; Ozpeynirci, Y.

    2015-01-01

    The purpose of this clinical feasibility study was to evaluate the applicability of magnetic resonance imaging (MRI) for the assessment of apical periodontitis in direct comparison with cone beam CT (CBCT). 19 consecutive patients (average age 43 ± 13 years) with 34 lesions in total (13 molars, 14 premolars and 7 front teeth) were enrolled in this feasibility study. Periapical lesions were defined as periapical radiolucencies (CBCT) or structural changes in the spongy bone signal (MRI), which were connected with the apical part of a root and with at least twice the width of the periodontal ligament space. The location and dimension of the lesions were compared between MRI and CBCT. While mainly mineralized tissue components such as teeth and bone were visible with CBCT, complimentary information of the soft tissue components was assessable with MRI. The MRI images provided sufficient diagnostic detail for the assessment of the main structures of interest. Heterogeneous contrast was observed within the lesion, with often a clear enhancement close to the apical foramen and the periodontal gap. No difference for lesion visibility was observed between MRI and CBCT. The lesion dimensions corresponded well, but were slightly but significantly overestimated with MRI. A heterogeneous lesion appearance was observed in several patients. Four patients presented with a well circumscribed hyperintense signal in the vicinity of the apical foramen. The MRI capability of soft tissue characterization may facilitate detailed analysis of periapical lesions. This clinical study confirms the applicability of multi-contrast MRI for the identification of periapical lesions.

  4. Revitalization of open apex teeth with apical periodontitis using a collagen-hydroxyapatite scaffold.

    Science.gov (United States)

    Nevins, Alan J; Cymerman, Jerome J

    2015-06-01

    An enhanced revision of the revitalization endodontic technique for immature teeth with apical periodontitis has been described. It includes the addition of collagen-hydroxyapatite scaffold to the currently practiced revascularization technique. Four cases treated in series are presented in this report, 1 case involving 2 teeth. Periapical diagnoses of immature teeth included "asymptomatic apical periodontitis," "symptomatic apical periodontitis," and "acute apical abscess." Additionally, 1 fully developed tooth that had undergone root canal treatment that failed had a periapical diagnosis of acute apical abscess. An established revascularization protocol was used for all teeth. In addition to stimulating blood clots, all teeth were filled with collagen-hydroxyapatite scaffolds. Periapical radiolucencies healed in all teeth, and diffuse radiopacity developed within the coronal portions of canal spaces. Root development with root lengthening occurred in the immature nonvital maxillary premolar that had not undergone prior treatment. The technique of adding a collagen-hydroxyapatite scaffold to the existing revitalization protocol has been described in which substantial hard tissue repair has occurred. This may leave teeth more fully developed and less likely to fracture. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Innovative Seals for Solid Oxide Fuel Cells (SOFC)

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Raj

    2008-06-30

    A functioning SOFC requires different type of seals such as metal-metal, metal-ceramic, and ceramic-ceramic. These seals must function at high temperatures between 600--900{sup o}C and in oxidizing and reducing environments of the fuels and air. Among the different type of seals, the metal-metal seals can be readily fabricated using metal joining, soldering, and brazing techniques. However, the metal-ceramic and ceramic-ceramic seals require significant research and development because the brittle nature of ceramics/glasses can lead to fracture and loss of seal integrity and functionality. Consequently, any seals involving ceramics/glasses require a significant attention and technology development for reliable SOFC operation. This final report is prepared to describe the progress made in the program on the needs, approaches, and performance of high temperature seals for SOFC. In particular, a new concept of self-healing glass seals is pursued for making seals between metal-ceramic material combinations, including some with a significant expansion mismatch.

  6. Hydrodynamic sensory threshold in harbour seals (Phoca vitulina) for artificial flatfish breathing currents.

    Science.gov (United States)

    Niesterok, Benedikt; Dehnhardt, Guido; Hanke, Wolf

    2017-07-01

    Harbour seals have the ability to detect benthic fish such as flatfish using the water currents these fish emit through their gills (breathing currents). We investigated the sensory threshold in harbour seals for this specific hydrodynamic stimulus under conditions which are realistic for seals hunting in the wild. We used an experimental platform where an artificial breathing current was emitted through one of eight different nozzles. Two seals were trained to search for the active nozzle. Each experimental session consisted of eight test trials of a particular stimulus intensity and 16 supra-threshold trials of high stimulus intensity. Test trials were conducted with the animals blindfolded. To determine the threshold, a series of breathing currents differing in intensity was used. For each intensity, three sessions were run. The threshold in terms of maximum water velocity within the breathing current was 4.2 cm s -1 for one seal and 3.7 cm s -1 for the other. We measured background flow velocities from 1.8 to 3.4 cm s -1 Typical swimming speeds for both animals were around 0.5 m s -1 Swimming speed differed between successful and unsuccessful trials. It appears that swimming speed is restricted for the successful detection of a breathing current close to the threshold. Our study is the first to assess a sensory threshold of the vibrissal system for a moving harbour seal under near-natural conditions. Furthermore, this threshold was defined for a natural type of stimulus differing from classical dipole stimuli which have been widely used in threshold determination so far. © 2017. Published by The Company of Biologists Ltd.

  7. 21 CFR 864.9750 - Heat-sealing device.

    Science.gov (United States)

    2010-04-01

    ... and Blood Products § 864.9750 Heat-sealing device. (a) Identification. A heat-sealing device is a device intended for medical purposes that uses heat to seal plastic bags containing blood or blood... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heat-sealing device. 864.9750 Section 864.9750...

  8. Refurbishing the seals of the H2S compressors in the isotopic exchange installations at the Heavy Water Reprocessing Plant. Technical solutions for replacing liquid seals by dry seals

    International Nuclear Information System (INIS)

    Panait; Adrian; Serban, Viorel; Androne, Marian; Florea, Ioana; Ciocan, George; State, Elena

    2004-01-01

    An analysis of the present sealing system in the H 2 S compressors showed that the risk of accidental hydrogen sulfide escape into the atmosphere is high in case of a seal oil pressure loss. At the same time there exist drawbacks occurring even in normal regime of functioning among which one can mention: - relatively high losses of oil occur, part of the oil being carried away by the compressors and released into the isotopic exchange columns where the water counter current flow produces a foaming that reduces the column processing capacity; - part of the sealing oil leaks reaches the final product, the heavy water, where from it must be removed by chemical procedures; - the installations adjacent to the sealing system are relatively sophisticated and require relatively high expenses for exploitation and maintenance. The classical sealing systems using sealing rings, sleeves, labyrinths, etc, cannot be used since their safe working range is exceeded due to either driving shaft rotational speed, or to the increase of its diameter, or else to an increase of the speed of motion of moving parts relative to the fix parts. The sealing systems with magnetic liquids are rather sophisticated and expensive while in case of electric supply loss they are completely unsafe, because their sealing capacity vanishes. The materials used for sealing gaskets limit their application only to the cases when the relative motion of the moving pieces is low or vanishing what happens only at shut down or failure situations. To prevent these drawbacks of the present seal system in the H 2 S compressors of the isotopic exchange columns and having in view the limitations of the currently used sealing systems a new system of sealing was conceived and designed on the basis of the patent titled 'Sealing Installation and Procedure' recorded by OSIM under No. A/0315/10.04.2003. The new system can be built as a single or double stage each of them having in turn a dynamic and a static sub-stage. The

  9. How far is the root apex of a unilateral impacted canine from the root apices' arch form?

    Science.gov (United States)

    Kim, Sung-Hun; Kim, You-Min; Oh, Sewoong; Kim, Seong-Sik; Park, Soo-Byung; Son, Woo-Sung; Kim, Yong-Il

    2017-02-01

    The purpose of this study was to determine the arch form of the root apices of normally erupting teeth and then determine the differences in the location of the apex of impacted canines relative to normally erupting canines. In addition, we sought to determine whether the labiopalatal position of the impacted canines influences the position of the apices. The study included 21 patients with unerupted canines that subsequently had a normal eruption, 21 patients with palatally impacted canines, 27 patients with labially impacted canines, and 17 patients with midalveolus impacted canines. Images were obtained using cone beam computed tomography, and the x, y, and z coordinates of the root apices were determined using Ondemand3D software (Cybermed Co., Seoul, Korea). Two-dimensional coordinates were converted from acquired 3-dimensional coordinates via projection on a palatal plane, and the Procrustes method was used to process the converted 2-dimensional coordinates and to draw the arch forms of the root apices. Finally, we measured the extent of root apex deviation from the arch forms of the root apices. Normally erupting canines showed that even though calcifications may be immature, their positions were aligned with a normal arch form. The root apices of the impacted canines were an average of 6.572 mm away from the root apices' arch form, whereas those of the contralateral nonimpacted canines were an average distance of 2.221 mm away, a statistically significant difference. The palatally impacted canines' root apices distribution tended toward the first premolar root apices. Incompletely calcified, unerupted teeth with a subsequent normal eruption showed a normal arch form of the root apices. The root apices of impacted canines were farther from the arch forms than were the nonimpacted canines. Also, the root apices of impacted canines in the palatal area showed distributions different from those of the other impacted canine groups. Copyright © 2017 American

  10. Improved cryogenic shaft seals

    Science.gov (United States)

    Gillon, W. A., Jr.; Tellier, G. F.

    1976-01-01

    Seals are designed for use with liquid propellant ball valves at temperatures ranging from -400 F to 130 F and 8,000 psig. Seals are capable of sustaining 90 degree rotation, with substantial amount of lateral and axial play, caused by large pressure loads and differential thermal contraction.

  11. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  12. Magnetically Actuated Seal, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a magnetically actuated dynamic seal. Dynamic seals are used throughout the turbopump in high-performance, pump-fed, liquid rocket...

  13. Magnetically Actuated Seal, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a magnetically actuated dynamic seal. Dynamic seals are used throughout the turbopump in high-performance, pump-fed, liquid rocket...

  14. Breaking into the epithelial apical-junctional complex--news from pathogen hackers.

    Science.gov (United States)

    Vogelmann, Roger; Amieva, Manuel R; Falkow, Stanley; Nelson, W James

    2004-02-01

    The epithelial apical-junctional complex is a key regulator of cellular functions. In addition, it is an important target for microbial pathogens that manipulate the cell to survive, proliferate and sometimes persist within a host. Out of a myriad of potential molecular targets, some bacterial and viral pathogens have selected a subset of protein targets at the apical-junctional complex of epithelial cells. Studying how microbes use these targets also teaches us about the inherent physiological properties of host molecules in the context of normal junctional structure and function. Thus, we have learned that three recently uncovered components of the apical-junctional complex of the Ig superfamily--junctional adhesion molecule, Nectin and the coxsackievirus and adenovirus receptor--are important regulators of junction structure and function and represent critical targets of microbial virulence gene products.

  15. Guide to optimized replacement of equipment seals

    International Nuclear Information System (INIS)

    Gleason, J.F.

    1990-03-01

    A reevaluation of current scheduled replacement intervals of polymeric seals in plant equipment can achieve significant benefits. Information is provided which has the potential for increasing replacement intervals based on better information on how seals have performed through unique nuclear industry tests to qualify equipment, improved elastomers and increased knowledge of the failure mechanisms and related performance. The research was performed by reviewing applications of elastomeric seals in nuclear plants and practice associated with defining seal replacement intervals in the nuclear power and other industries. Performance indicators and how they predict degradation of seals were evaluated. Guidelines and a flow chart for reevaluating seal replacement intervals are provided. 29 refs., 38 figs., 8 tabs

  16. The effect of immediate and delayed post-space preparation using extended working time root canal sealers on apical leakage

    Directory of Open Access Journals (Sweden)

    G. Chen

    2013-03-01

    Conclusion: Extended working time root canal sealers do not affect microleakage results using a warm gutta-percha vertical compaction technique. The sealing ability of extended working time root canal sealers on high heat conditions is as good as the standard working time root canal sealer during post-space preparation of different intervals.

  17. Analysis of end-face seals by FEM

    Directory of Open Access Journals (Sweden)

    Juraszek J.

    2002-09-01

    Full Text Available The end face-seals joint simultaneously the function of seal, bearing and heat exchanger. In order to improve the design of end-face seals the analysis of this type of joint by means of finite element method, was developed. The temperature distribution is indispensable to the analysis of displacement and stress in this type of face seal. In this work the values of temperature and stress in end-face seals were calculated. The numerical results were confirmed by measurements in the laboratory.

  18. Evaluation of the root canal shaping ability of two rotary nickel-titanium systems.

    Science.gov (United States)

    Al-Manei, K K; Al-Hadlaq, S M S

    2014-10-01

    The aim was to investigate the canal shaping abilities of the twisted file (TF) and GT series X file (GTX) systems. Sixty mesial root canals of mandibular molars with curvatures of 15-50° were divided randomly into two groups of 30 canals each. The teeth were sectioned horizontally at 3, 6 and 9 mm from the apex. Root canals were prepared with TF and GTX files, respectively, and the shaping abilities of the systems were evaluated at three levels (coronal, middle and apical) based on the comparison of pre- and post-instrumentation photographs using AutoCAD software. Preparation time was also assessed. Data from the two groups were compared statistically using the Student's t-test. There was no significant difference between the rotary systems in terms of change in root canal cross-sectional area, root canal transportation, centring ability or minimum dentine thickness. Remaining dentine thickness at the coronal and middle levels was similar in the TF and GTX groups, but GTX instruments left significantly less dentine than TF instruments on the mesial aspects of root canals at the apical level. Root canal preparation with TF instruments required significantly less time than with GTX instruments. The TF and GTX NiTi rotary instruments showed similar shaping abilities, but root canal preparation was more rapid with the TF than with the GTX system. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. Apical Cyst Theory: a Missing Link.

    Science.gov (United States)

    Huang, George T-J

    2010-10-05

    The mechanism of the formation of apical cyst has been elusive. Several theories have long been proposed and discussed speculating how an apical cyst is developed and formed in the jaw bone resulting from endododontic infection. Two popular theories are the nutritional deficiency theory and the abscess theory. The nutritional deficiency theory assumes that the over proliferated epithelial cells will form a ball mass such that the cells in the center of the mass will be deprived of nutrition. The abscess theory postulates that when an abscess cavity is formed in connective tissue, epithelial cells proliferate and line the preexisting cavity because of their inherent tendency to cover exposed connective tissue surfaces. Based on the nature of epithelial cells and the epithelium, nutritional theory is a fairy tale, while abscess theory at best just indicates that abscess may be one of the factors that allows the stratified epithelium to form but not to explain a mechanism that makes the cyst to form. Apical cyst formation is the result of proliferation of resting epithelial cells, due to inflammation, to a sufficient number such that they are able to form a polarized and stratified epithelial lining against dead tissues or foreign materials. These stratified epithelial lining expands along the dead tissue or foreign materials and eventually wrap around them as a spherical sac, i.e. a cyst. The space in the sac is considered the external environment separating the internal (tissue) environment - the natural function of epithelium. This theory may be tested by introducing a biodegradable device able to slowly release epithelial cell mitogens in an in vivo environment implanted with epithelial cells next to a foreign object. This will allow the cells to continuously proliferate which may form a cystic sac wrapping around the foreign object.

  20. Utilizing the GentleWave® System for Debridement of Undetected Apical Anatomy.

    Science.gov (United States)

    Ford, Michael W

    2018-03-01

    Debriding and disinfecting complex anatomies within the root canal system pose a major challenge during root canal therapy. Even with current chemomechanical techniques, debris and bacterial remnants are commonly left behind, which are generally believed to increase the risk of endodontic failure. This case details the use of a new technique to debride complex apical anatomy in a maxillary molar. A 48-year-old female presented to the clinic with a chief complaint of increasing pain in her tooth. Clinical examination of the right first maxillary molar (#3) revealed moderate sensitivity to percussion and mild sensitivity to palpation. A pulpal diagnosis of symptomatic irreversible pulpitis and a periapi-cal diagnosis of symptomatic apical periodontitis were made. Mechanical instrumentation was performed using rotary file size #25/.04 for the mesiobuccal and distobuccal canals and size #25/.06 for the palatal canal to create a fluid path and enable obturation of the root canal system following the GentleWave® Procedure. The GentleWave Procedure was completed using Multisonic Ultracleaning™ for complete debridement and disinfection of the root canal system. The tooth was obturated using a warm vertical continuous wave obturation technique. Postoperative radiographs revealed complex anatomy within the apical third that was undetected both during pre-operative radiography and mechanical instrumentation. The palatal canal exhibited a complex apical delta with multiple points of exit, and the mesiobuccal canal revealed an undetected lateral canal within the apical third that had a separate and distinct egress. Conclusion and clinical significance: It is important for the clinician to debride and disinfect complex anatomy within the root canal system to reduce the risk of endodontic failure. This case report highlights the clinical significance of utilizing the GentleWave Procedure for detecting complex apical anatomy during endodontic therapy.

  1. Distribution and function of HCN channels in the apical dendritic tuft of neocortical pyramidal neurons.

    Science.gov (United States)

    Harnett, Mark T; Magee, Jeffrey C; Williams, Stephen R

    2015-01-21

    The apical tuft is the most remote area of the dendritic tree of neocortical pyramidal neurons. Despite its distal location, the apical dendritic tuft of layer 5 pyramidal neurons receives substantial excitatory synaptic drive and actively processes corticocortical input during behavior. The properties of the voltage-activated ion channels that regulate synaptic integration in tuft dendrites have, however, not been thoroughly investigated. Here, we use electrophysiological and optical approaches to examine the subcellular distribution and function of hyperpolarization-activated cyclic nucleotide-gated nonselective cation (HCN) channels in rat layer 5B pyramidal neurons. Outside-out patch recordings demonstrated that the amplitude and properties of ensemble HCN channel activity were uniform in patches excised from distal apical dendritic trunk and tuft sites. Simultaneous apical dendritic tuft and trunk whole-cell current-clamp recordings revealed that the pharmacological blockade of HCN channels decreased voltage compartmentalization and enhanced the generation and spread of apical dendritic tuft and trunk regenerative activity. Furthermore, multisite two-photon glutamate uncaging demonstrated that HCN channels control the amplitude and duration of synaptically evoked regenerative activity in the distal apical dendritic tuft. In contrast, at proximal apical dendritic trunk and somatic recording sites, the blockade of HCN channels decreased excitability. Dynamic-clamp experiments revealed that these compartment-specific actions of HCN channels were heavily influenced by the local and distributed impact of the high density of HCN channels in the distal apical dendritic arbor. The properties and subcellular distribution pattern of HCN channels are therefore tuned to regulate the interaction between integration compartments in layer 5B pyramidal neurons. Copyright © 2015 the authors 0270-6474/15/351024-14$15.00/0.

  2. Identification of apical vertebra for grading of idiopathic scoliosis using image processing.

    Science.gov (United States)

    Anitha, H; Prabhu, G K

    2012-02-01

    Scoliosis is a 3-D deformity of spinal column, characterized by both lateral curvature and vertebral rotation. The disease can be caused by congenital, developmental, or degenerative problems; but most cases of scoliosis actually have no known cause, and this is known as idiopathic scoliosis. Vertebral rotation has become increasingly prominent in the study of scoliosis and the most deformed vertebra is named as apical vertebra. Apical vertebral deformity demonstrates significance in both preoperative and postoperative assessment, providing better appreciation of the impact of bracing or surgical interventions. Precise measurement of apical vertebral rotation in terms of grading is most valuable for the determination of reference value in normal and pathological conditions for better understanding of scoliosis. Routine quantitative evaluation of vertebral rotation is difficult and error prone due to limitations of observer characteristic and specific imaging property. This paper proposes automatic identification of the apical vertebra and its parameter that depends on the objective criteria of measurement using active contour models. The proposed technique is more accurate and is a reliable measurement compared to manual and computer-assisted system.

  3. Sealing device and method for sealing fractures or leaks in wall or formation surrounding tube-shaped channel

    DEFF Research Database (Denmark)

    2014-01-01

    The sealing device (1) includes an elongated body (5) adapted to be introduced into a tube-shaped channel (2) and including a sealing fluid placement section (6) arranged between a first and a second annular flow barrier (7, 8). The elongated body further includes a sealing fluid activation secti...

  4. Quick-sealing design for radiological containment

    International Nuclear Information System (INIS)

    Rampdla, D.S.; Speer, E.

    1991-01-01

    This patent describes a quick-sealing assembly and method for forming an adhesive seal on opposite sides of a mechanical seal for a flexible containment bag of the type used for working with radioactively contaminated objects. The assembly includes an elongated mechanical fastener having opposing engaging members affixed at a predetermined distance from each of the elongated edges, with an adhesive layer formed between the mechanical fastener and the elongated edge such that upon engagement of the mechanical fastener and adhesive layers to opposing containment fabric, a neat triple hermetic seal is formed

  5. Quick-sealing design for radiological containment

    International Nuclear Information System (INIS)

    Rampolia, D.S.; Speer, E.

    1990-01-01

    This patent describes a quick-sealing assembly and method for forming an adhesive seal on opposite sides of a mechanical seal for a flexible containment bag of the type used for working with radioactively contaminated objects. The assembly includes an elongated mechanical fastener having opposing engaging members affixed at a predetermined distance from each of the elongated edges, with an adhesive layer formed between the mechanical fastener and the elongated edge such that upon engagement of the mechanical fastener and adhesive layers to opposing containment fabric, a neat triple hermetic seal is formed

  6. Quick-sealing design for radiological containment

    Science.gov (United States)

    Rampolia, Donald S.; Speer, Elmer

    1990-01-01

    A quick-sealing assembly and method for forming an adhesive seal on opposite sides of a mechanical seal for a flexible containment bag of the type used for working with radioactively contaminated objects. The assembly includes an elongated mechanical fastener having opposing engaging members affixed at a predetermined distance from each of the elongated edges, with an adhesive layer formed between the mechanical fastener and the elongated edge such that upon engagement of the mechanical fastener and adhesive layers to opposing containment fabric, a neat triple hermetic seal is formed.

  7. Auto-identification fiberoptical seal verifier

    International Nuclear Information System (INIS)

    Yamamoto, Yoichi; Mukaiyama, Takehiro

    1998-08-01

    An auto COBRA seal verifier was developed by Japan Atomic Energy Research Institute (JAERI) to provide more efficient and simpler inspection measures for IAEA safeguards. The verifier is designed to provide means of a simple, quantitative and objective judgment on in-situ verification for the COBRA seal. The equipment is a portable unit with hand-held weight and size. It can be operated by battery or AC power. The verifier reads a COBRA seal signature by using a built-in CCD camera and carries out the signature comparison procedure automatically on digital basis. The result of signature comparison is given as a YES/NO answer. The production model of the verifier was completed in July 1996. The development was carried out in collaboration with Mitsubishi Heavy Industries, Ltd. This report describes the design and functions of the COBRA seal verifier and the results of environmental and functional tests. The development of the COBRA seal verifier was carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JD-4 since 1981. (author)

  8. Conversion of proteins from a non-polarized to an apical secretory pattern in MDCK cells

    International Nuclear Information System (INIS)

    Vogel, Lotte K.; Larsen, Jakob E.; Hansen, Martin; Truffer, Renato

    2005-01-01

    Previously it was shown that fusion proteins containing the amino terminus of an apical targeted member of the serpin family fused to the corresponding carboxyl terminus of the non-polarized secreted serpin, antithrombin, are secreted mainly to the apical side of MDCK cells. The present study shows that this is neither due to the transfer of an apical sorting signal from the apically expressed proteins, since a sequence of random amino acids acts the same, nor is it due to the deletion of a conserved signal for correct targeting from the non-polarized secreted protein. Our results suggest that the polarity of secretion is determined by conformational sensitive sorting signals

  9. Auditory brainstem activity and development evoked by apical versus basal cochlear implant electrode stimulation in children.

    Science.gov (United States)

    Gordon, K A; Papsin, B C; Harrison, R V

    2007-08-01

    The role of apical versus basal cochlear implant electrode stimulation on central auditory development was examined. We hypothesized that, in children with early onset deafness, auditory development evoked by basal electrode stimulation would differ from that evoked more apically. Responses of the auditory nerve and brainstem, evoked by an apical and a basal implant electrode, were measured over the first year of cochlear implant use in 50 children with early onset severe to profound deafness who used hearing aids prior to implantation. Responses at initial stimulation were of larger amplitude and shorter latency when evoked by the apical electrode. No significant effects of residual hearing or age were found on initial response amplitudes or latencies. With implant use, responses evoked by both electrodes showed decreases in wave and interwave latencies reflecting decreased neural conduction time through the brainstem. Apical versus basal differences persisted with implant experience with one exception; eIII-eV interlatency differences decreased with implant use. Acute stimulation shows prolongation of basally versus apically evoked auditory nerve and brainstem responses in children with severe to profound deafness. Interwave latencies reflecting neural conduction along the caudal and rostral portions of the brainstem decreased over the first year of implant use. Differences in neural conduction times evoked by apical versus basal electrode stimulation persisted in the caudal but not rostral brainstem. Activity-dependent changes of the auditory brainstem occur in response to both apical and basal cochlear implant electrode stimulation.

  10. The use of dual material seals for packaging

    International Nuclear Information System (INIS)

    Temus, C.J.; Nichols, J.C.

    2004-01-01

    The use of dual material seals, metal and elastomeric for a transportation package, provides a viable option for packages requiring high temperature seal capability. Allowing the seal area to go to higher temperatures then allowed for all elastomeric seal reduce the necessity of providing thermal protection during a postulated accident condition fire. It also increases the options for impact limiting features that do not also mitigate the affects of accident thermal events. Typically, high temperature seals require the use of metal O-rings. Only one seal (typically identified as the containment seal) needs to survive the hypothetical accident conditions, including the high temperatures that may occur during the prescribed hypothetical thermal event. However, to expedite the assembly leakage rate testing of radioactive material packages, a dual O-ring seal arrangement is often used to allow creation of a relatively small volume test cavity between the seals. For any package that is being used on a frequent basis, the total cost of seals can be significantly reduced by using an elastomeric seal as the secondary seal. The elastomeric seal is not the containment boundary seal and does not need to survive the high temperature condition. To get the dual material O-ring seals to seat properly, a different approach has to be taken than with closure of a radioactive material package that does not use metallic O-ring(s). A metal O-ring requires an application of a seating force while the elastomeric package requires a certain percentage of deformation. This is further complicated when the seating force is developed using a multi-bolt closure. Because of the nature of multi-bolt closures, elastic interaction prevents the equal application of force. This paper develops the methods involved in properly closing and establishing containment when using dual material seals with a multi-bolt closure. These methods were demonstrated in two production casks requiring testing leak

  11. HFCVD Diamond-Coated Mechanical Seals

    Directory of Open Access Journals (Sweden)

    Raul Simões

    2018-05-01

    Full Text Available A mechanical seal promotes the connection between systems or mechanisms, preventing the escape of fluids to the exterior. Nonetheless, due to extreme working conditions, premature failure can occur. Diamond, due to its excellent properties, is heralded as an excellent choice to cover the surface of these devices and extend their lifetime. Therefore, the main objective of this work was to deposit diamond films over mechanical seals and test the coated seals on a water pump, under real working conditions. The coatings were created by hot filament chemical vapor deposition (HFCVD and two consecutive layers of micro- and nanocrystalline diamond were deposited. One of the main difficulties is the attainment of a good adhesion between the diamond films and the mechanical seal material (WC-Co. Nucleation, deposition conditions, and pre-treatments were studied to enhance the coating. Superficial wear or delamination of the film was investigated using SEM and Raman characterization techniques, in order to draw conclusions about the feasibility of these coatings in the WC-Co mechanical seals with the purpose of increasing their performance and life time. The results obtained gave a good indication about the feasibility of this process and the deposition conditions used, with the mechanical seals showing no wear and no film delamination after a real work environment test.

  12. Treatment of Angio-Seal-Related Femoral Artery Occlusion Using Directional Atherectomy-Primary Results and Midterm Follow-Up.

    Science.gov (United States)

    Babaev, Anvar; Gokhale, Rohit; Zavlunova, Susanna; Attubato, Michael

    2016-11-01

    We describe a novel approach for the endovascular treatment of femoral artery occlusion as a result of Angio-Seal closure device deployment. Angio-Seal is the most commonly used vascular closure device following percutaneous coronary and peripheral catheterizations worldwide. A rare complication of Angio-Seal deployment is an occlusion of the femoral artery leading to limb ischemia requiring revascularization. Given its unique ability to cut both atherosclerotic plaque and the Angio-Seal anchor with a collagen plug at operator-directed planes, TurboHawk/HawkOne atherectomy device can be a fast and effective approach to treat Angio-Seal-associated femoral artery occlusions. We studied 13 consecutive patients who developed Angio-Seal-associated femoral artery occlusions that occurred from 3 hours to several weeks after catheterization. These patients were successfully treated with TurboHawk/HawkOne directional atherectomy followed by balloon angioplasty with no complications. During a mean follow-up period of 20.4 ± 17.3 months, 12 patients remained claudication free with no evidence of obstructive arterial disease of the treated segment on imaging studies. One patient developed restenosis that was treated with repeat atherectomy and balloon angioplasty following which he was asymptomatic at follow-up. The use of directional atherectomy followed by balloon angioplasty is a quick, safe, and effective endovascular approach to treating Angio-Seal-associated femoral artery occlusions. It is associated with an excellent success rate, no complications, and good midterm outcomes.

  13. Laboratory studies of fluid flow through borehole seals

    International Nuclear Information System (INIS)

    South, D.L.

    1983-01-01

    Boreholes in the vicinity of a nuclear waste repository must be reliably sealed to prevent rapid migration of radionuclide contaminated water from the vicinity of the repository to the accessible environment. Few data currently exist regarding the effectiveness of borehole sealing. The objective of this research was to assess the performance of borehole seals under laboratory conditions, particularly with regard to varying stress fields. The approach used to evaluate borehole seals was to compare flow through a sealed borehole with flow through intact rock. Granite, basalt, and tuff were tested, using either cement or bentonite as the seal material. The main conclusions reached as a result of the experiments is that currently existing materials are capable of forming high quality seals when placed under laboratory conditions. Variation of triaxial stress state about a borehole does not significantly affect seal performance if the rock is stiffer than the seal material. Temperature/moisture variations (drying) degraded the quality of cement seals significantly. Performance partially recovered upon resaturation. Significant remaining questions include field emplacement techniques; field vertification of plug quality; plug performance over long time periods, particularly with respect to temperature/moisture variations and chemical stability; and radionuclide sorption capabilities. Scale effects are also important, as shafts and drifts must be sealed as well as larger diameter boreholes

  14. Type III apical transportation of root canal

    Directory of Open Access Journals (Sweden)

    Shiv P Mantri

    2012-01-01

    Full Text Available Procedural accidents leading to complications such as canal transportation have been ascribed to inapt cleaning and shaping concepts. Canal transportation is an undesirable deviation from the natural canal path. Herewith a case of apical transportation of root canal resulting in endodontic retreatment failure and its management is presented. A healthy 21-year-old young male presented discomfort and swelling associated with painful endodontically retreated maxillary incisor. Radiograph revealed periradicular radiolucency involving underfilled 11 and overfilled 12. Insufficiently obturated 11 exhibited apical transportation of canal. This type III transportation was treated by periradicular surgery and repair using white mineral trioxide aggregate (MTA. Comfortable asymptomatic patient presented uneventful healing at third and fourth month recall visits. A decrease in the size of radiolucency in radiograph supported the clinical finding. In the present case, MTA is useful in repairing the transportation defect. The result of these procedures is predictable and successful.

  15. Changes of Root Length and Root-to-Crown Ratio after Apical Surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Jensen, Simon S; Bornstein, Michael M

    2015-01-01

    INTRODUCTION: Apical surgery is an important treatment option for teeth with post-treatment periodontitis. Although apical surgery involves root-end resection, no morphometric data are yet available about root-end resection and its impact on the root-to-crown ratio (RCR). The present study assess...

  16. Miniature magnetic fluid seal working in liquid environments

    Science.gov (United States)

    Mitamura, Yoshinori; Durst, Christopher A.

    2017-06-01

    This study was carried out to develop a miniature magnetic fluid (MF) seal working in a liquid environment. The miniature MF seal is intended for use in a catheter blood pump. The requirements for the MF seal included a size of less than Ø4×4.5 mm, shaft diameter of 1 mm, sealing pressure of 200 mmHg, shaft speed of up to 40000 rpm, and life of one month. The miniature MF seal was composed of an NdFeB magnet (Ø4×Ø2×1) sandwiched between two pole pieces (Ø4×Ø1.1×0.5). A shield (Ø4×Ø1.2×1.5) was placed on the pole piece facing the liquid to minimize the influence of pump flow on the MF. The seal was installed on a Ø1 shaft. A seal was formed by injecting MF (Ms: 47.8 kA/m and η: 0.5 Pa·sec) into the gap between the pole pieces and the shaft. Total volume of the MF seal was 44 μL. A sealing pressure of 370 mmHg was obtained at motor speeds of 0-40,000 rpm. The seal remained perfect for 10 days in saline under the condition of a pump flow of 1.5 L/min (The test was terminated in accordance with plans). The seal remained intact after ethylene oxide sterilization during which the seal was exposed to high pressures. In conclusion, the newly developed MF seal will be useful for a catheter pump.

  17. Application of EIS to In Situ Characterization of Hydrothermal Sealing of Anodized Aluminum Alloys: Comparison between Hexavalent Chromium-Based Sealing, Hot Water Sealing and Cerium-Based Sealing

    OpenAIRE

    Carangelo, Anna; Curioni, Michele; Acquesta, Annalisa; Monetta, Tullio; Bellucci, Francesco

    2016-01-01

    Chromic acid anodizing has been used for almost a century to enhance corrosion protection of aerospace alloys. For some applications,hydrothermal sealing in hexavalent chromium-containing solution is required to enhance further the corrosion resistance but, due toenvironmental concerns, the use of hexavalent chromium must be discontinued. Good progress has been made to replace chromatesduring anodizing but comparatively less effort has focused on the sealing process. In this work, for the fir...

  18. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  19. Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Woo-Jin Lee

    2011-05-01

    Full Text Available Objectives The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file hand file, ProFile and LightSpeed using microcomputed tomography (MCT. Materials and Methods Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1- , 2- , 3- , and 5- mm level from the apex. Data were statistically analyzed according to' repeated nested design'and Mann-Whitney test (p = 0.05. Results In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

  20. Numerical Investigation on Windback Seals Used in Aero Engines

    Directory of Open Access Journals (Sweden)

    Michael Flouros

    2018-01-01

    Full Text Available Seals are considered one of the most important flow elements in turbomachinery applications. The most traditional and widely known seal is the labyrinth seal but in recent years other types like the brush or carbon seals were introduced since they considerably reduce the sealing air consumption. When seals are used for sealing of aero engine bearing chambers they are subjected to high “bombardment” through oil particles which are present in the bearing chamber. These particles mainly result from the bearings as a consequence of the high rotational speeds. Particularly when carbon or brush seals are used, problems with carbon formation (coking may arise when oil gets trapped in the very tight gap of these seals. In order to prevent oil migration into the turbomachinery, particularly when the pressure difference over a seal is small or even negligible, significant improvement can be achieved through the introduction of so called windback seals. This seal has a row of static helical teeth (thread and below this thread a scalloped or smooth shaft section is rotating. Depending on the application, a windback seal can be used alone or as a combination with another seal (carbon, brush or labyrinth seal. A CFD analysis carried out with ANSYS CFX version 11 is presented in this paper with the aim to investigate this seal type. The simulations were performed by assuming a two-phase flow of air and oil in the bearing compartment. Design parameters like seal clearance, thread size, scallop width, were investigated at different operating conditions.

  1. Sealing Occlusal Dentin Caries in Permanent Molars

    DEFF Research Database (Denmark)

    Qvist, Vibeke; Borum, Mette Kit; Møller, Kirsten Dynes

    2017-01-01

    The purpose of this study was to investigate the possibility of postponing restorative intervention of manifest occlusal caries in young, permanent dentition by non-invasive sealing. This RCT-designed study included 521 occlusal lesions in 521 patients aged 6 to 17 y. Based on clinical and radiog......The purpose of this study was to investigate the possibility of postponing restorative intervention of manifest occlusal caries in young, permanent dentition by non-invasive sealing. This RCT-designed study included 521 occlusal lesions in 521 patients aged 6 to 17 y. Based on clinical...... longevity of sealings and restorations until retreatments, and 3) compare effectiveness of sealings and restorations to halt caries progression in sealed lesions and beneath restorations. Furthermore, we aimed to identify factors influencing longevity and the effectiveness of sealings and restorations.......001). The median survival time for sealings not replaced by restorations was 7.3 y (CI, 6.4 y to NA). Survival of sealings was increased in patients with low caries risk and/or excellent oral hygiene, second molars compared with first molars, and lesions not extending the middle one-third of the dentin. Survival...

  2. An in vitro comparison of apically extruded debris using three rotary nickel-titanium instruments

    Directory of Open Access Journals (Sweden)

    Tamer Tasdemir

    2010-09-01

    Conclusion: According to this study, all instrumentation techniques apically extruded debris through the apical foramen. However, the BioRaCe instruments induced less extruded debris than the ProTaper Universal and Mtwo rotary systems.

  3. Chimaerin suppresses Rac1 activation at the apical membrane to maintain the cyst structure.

    Directory of Open Access Journals (Sweden)

    Shunsuke Yagi

    Full Text Available Epithelial organs are made of a well-polarized monolayer of epithelial cells, and their morphology is maintained strictly for their proper functions. Previously, we showed that Rac1 activation is suppressed at the apical membrane in the mature organoid, and that such spatially biased Rac1 activity is required for the polarity maintenance. Here we identify Chimaerin, a GTPase activating protein for Rac1, as a suppressor of Rac1 activity at the apical membrane. Depletion of Chimaerin causes over-activation of Rac1 at the apical membrane in the presence of hepatocyte growth factor (HGF, followed by luminal cell accumulation. Importantly, Chimaerin depletion did not inhibit extension formation at the basal membrane. These observations suggest that Chimaerin functions as the apical-specific Rac1 GAP to maintain epithelial morphology.

  4. Floating seal system for rotary devices

    Science.gov (United States)

    Banasiuk, H.A.

    1983-08-23

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10[degree] to about 30[degree] in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device. 5 figs.

  5. Metal and elastomer seal tests for accelerator applications

    International Nuclear Information System (INIS)

    Welch, K.M.; McIntyre, G.T.; Tuozzolo, J.E.; Skelton, R.; Pate, D.J.; Gill, S.M.

    1989-01-01

    The vacuum system of the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory has more than a thousand metal vacuum seals. Also, numerous elastomer seals are used throughout the AGS to seal large beam component chambers. An accelerator upgrade program is being implemented to reduce the AGS operating pressure by x100 and improve the reliability of the vacuum system. This paper describes work in progress on metal and elastomer vacuum seals to help meet those two objectives. Tests are reported on the sealing properties of a variety of metal seals used on different sealing surfaces. Results are also given on reversible sorption properties of certain elastomers. 16 refs., 6 figs., 4 tabs

  6. Apparatus and method for inspecting a sealed container

    Science.gov (United States)

    Harmon, J Frank [Pocatello, ID; Jones, James L [Idaho Falls, ID; Hunt, Alan W [Pocatello, ID; Spaulding, Randy J [Pocatello, ID; Smith, Michael [Phoenix, AZ

    2009-03-24

    An apparatus for inspecting a sealed container is disclosed and which includes a pulsed electron accelerator which is positioned in spaced relation relative to a first side of the sealed container, and which produces a pulsed beam of photons which passes through the sealed container and any contents enclosed within the sealed container; a detector positioned in spaced relation relative to a second, opposite side of the sealed container, and which receives the pulsed beam of photons which passes through the contents of the sealed container, and which produces an output signal; and a computer for developing a visible image from the output signal of the detector which depicts the contents of the sealed container.

  7. A reappraisal of the role of abscisic acid and its interaction with auxin in apical dominance.

    Science.gov (United States)

    Cline, Morris G; Oh, Choonseok

    2006-10-01

    Evidence from pea rms1, Arabidopsis max4 and petunia dad1 mutant studies suggest an unidentified carotenoid-derived/plastid-produced branching inhibitor which moves acropetally from the roots to the shoots and interacts with auxin in the control of apical dominance. Since the plant hormone, abscisic acid (ABA), known to inhibit some growth processes, is also carotenoid derived/plastid produced, and because there has been indirect evidence for its involvement with branching, a re-examination of the role of ABA in apical dominance is timely. Even though it has been determined that ABA probably is not the second messenger for auxin in apical dominance and is not the above-mentioned unidentified branching inhibitor, the similarity of their derivation suggests possible relationships and/or interactions. The classic Thimann-Skoog auxin replacement test for apical dominance with auxin [0.5 % naphthalene acetic acid (NAA)] applied both apically and basally was combined in similar treatments with 1 % ABA in Ipomoea nil (Japanese Morning Glory), Solanum lycopersicum (Better Boy tomato) and Helianthus annuus (Mammoth Grey-striped Sunflower). Auxin, apically applied to the cut stem surface of decapitated shoots, strongly restored apical dominance in all three species, whereas the similar treatment with ABA did not. However, when ABA was applied basally, i.e. below the lateral bud of interest, there was a significant moderate repression of its outgrowth in Ipomoea and Solanum. There was also some additive repression when apical auxin and basal ABA treatments were combined in Ipomoea. The finding that basally applied ABA is able partially to restore apical dominance via acropetal transport up the shoot suggests possible interactions between ABA, auxin and the unidentified carotenoid-derived branching inhibitor that justify further investigation.

  8. Selection of vacuum seals for EBT-P

    International Nuclear Information System (INIS)

    Dillow, C.F.; Adlon, G.L.; Stubblefield, V.E.

    1981-01-01

    Elmo Bumpy Torus Proof of Principle (EBT-P) is a magnetic fusion RandD facility being constructed by McDonnell Douglas Astronautics Company - St. Louis Division of Oak Ridge National Laboratory (ORNL). EBT-P is a truly unique fusion device requiring careful consideration in selecting both the primary vacuum seals on the toroidal vessel and the secondary vacuum seals in components such as vacuum pumps and and valves. The vacuum seal environment is described and the considerations in vacuum seal selection fully discussed. Methods for protecting vacuum seals in pumps and valves from the microwave environments are also presented

  9. Laparoscopic pectopexy: initial experience of single center with a new technique for apical prolapse surgery

    Directory of Open Access Journals (Sweden)

    Ahmet Kale

    Full Text Available ABSTRACT Objective: To share our first experience with laparoscopic pectopexy, a new technique for apical prolapse surgery, and to evaluate the feasibility of this technique. Materials and Methods: Seven patients with apical prolapse underwent surgery with laparoscopic pectopexy. The lateral parts of the iliopectineal ligament were used for a bilateral mesh fixation of the descended structures. The medical records of the patients were reviewed, and the short-term clinical outcomes were analyzed. Results: The laparoscopic pectopexy procedures were successfully performed, without intraoperative and postoperative complications. De novo apical prolapse, de novo urgency, de novo constipation, stress urinary incontinence, anterior and lateral defect cystoceles, and rectoceles did not occur in any of the patients during a 6-month follow-up period. Conclusion: Although laparoscopic sacrocolpopexy has shown excellent anatomical and functional long-term results, laparoscopic pectopexy offers a feasible, safe, and comfortable alternative for apical prolapse surgery. Pectopexy may increase a surgeon's technical perspective for apical prolapse surgery.

  10. Seal analysis technology for reactor pressure vessel

    International Nuclear Information System (INIS)

    Zheng Liangang; Zhang Liping; Yang Yu; Zang Fenggang

    2009-01-01

    There is the coolant with radiation, high temperature and high pressure in the reactor pressure vessel (RPV). It is closely correlated to RPV sealing capability whether the whole nuclear system work well or not. The aim of this paper is to study the seal analysis method and technology, such as the pre-tensioning of the bolt, elastoplastic contact and coupled technology of thermal and structure. The 3 D elastoplastic seal analysis method really and generally consider the loads and model the contact problem with friction between the contact plates. This method is easier than the specialized seal program and used widely. And it is more really than the 2 D seal analysis method. This 3 D elastoplastic seal analysis method has been successfully used in the design and analysis of RPV. (authors)

  11. N-Glycosylation instead of cholesterol mediates oligomerization and apical sorting of GPI-APs in FRT cells.

    Science.gov (United States)

    Imjeti, Naga Salaija; Lebreton, Stéphanie; Paladino, Simona; de la Fuente, Erwin; Gonzalez, Alfonso; Zurzolo, Chiara

    2011-12-01

    Sorting of glycosylphosphatidyl-inositol--anchored proteins (GPI-APs) in polarized epithelial cells is not fully understood. Oligomerization in the Golgi complex has emerged as the crucial event driving apical segregation of GPI-APs in two different kind of epithelial cells, Madin-Darby canine kidney (MDCK) and Fisher rat thyroid (FRT) cells, but whether the mechanism is conserved is unknown. In MDCK cells cholesterol promotes GPI-AP oligomerization, as well as apical sorting of GPI-APs. Here we show that FRT cells lack this cholesterol-driven oligomerization as apical sorting mechanism. In these cells both apical and basolateral GPI-APs display restricted diffusion in the Golgi likely due to a cholesterol-enriched membrane environment. It is striking that N-glycosylation is the critical event for oligomerization and apical sorting of GPI-APs in FRT cells but not in MDCK cells. Our data indicate that at least two mechanisms exist to determine oligomerization in the Golgi leading to apical sorting of GPI-APs. One depends on cholesterol, and the other depends on N-glycosylation and is insensitive to cholesterol addition or depletion.

  12. Sealed radioactive sources toolkit

    International Nuclear Information System (INIS)

    Mac Kenzie, C.

    2005-09-01

    The IAEA has developed a Sealed Radioactive Sources Toolkit to provide information to key groups about the safety and security of sealed radioactive sources. The key groups addressed are officials in government agencies, medical users, industrial users and the scrap metal industry. The general public may also benefit from an understanding of the fundamentals of radiation safety

  13. Method and system to facilitate sealing in gas turbines

    Science.gov (United States)

    Morgan, Victor John; Foster, Gregory Thomas; Sarawate, Neelesh Nandkumar

    2017-09-12

    A method and system for sealing between components within a gas turbine is provided. A first recess defined in a first component receives a seal member. A second recess defined in a second component adjacent the first component also receives the seal member. The first and second recesses are located proximate a hot gas path defined through the gas turbine, and define circumferential paths about the turbine axis. The seal member includes a sealing face that extends in a direction substantially parallel to the turbine axis. The seal member also includes a plurality of seal layers, wherein at least one of the seal layers includes at least one stress relief region for facilitating flexing of the first seal member.

  14. Silicone foam for penetration seal

    International Nuclear Information System (INIS)

    Hoshino, Yoshikazu

    1986-01-01

    In nuclear power plants or general buildings, it is very important to form a fire-resistant seal around cables, cable trays and conduits passing through a wall or a floor. Rockwool, asbestos, glasswool and flame-retarded urethane foam have so far been used for these purposes. However, they were not satisfactory in sealing property, workability and safety. The silicone foam newly developed, ''TOSSEAL'' 300, has cleared these defects. It has now come to be used for fire resistant seal in nuclear power plants. (author)

  15. Infiltrating/sealing proximal caries lesions

    DEFF Research Database (Denmark)

    Martignon, S; Ekstrand, K R; Gomez, J

    2012-01-01

    This randomized split-mouth controlled clinical trial aimed at assessing the therapeutic effects of infiltration vs. sealing for controlling caries progression on proximal surfaces. Out of 90 adult students/patients assessed at university clinics and agreeing to participate, 39, each with 3...... differences in lesion progression between infiltration and placebo (P = 0.0012) and between sealing and placebo (P = 0.0269). The study showed that infiltration and sealing are significantly better than placebo treatment for controlling caries progression on proximal lesions. No significant difference...

  16. Design and Calibration of a Full Scale Active Magnetic Bearing Based Test Facility for Investigating Rotordynamic Properties of Turbomachinery Seals in Multiphase Flow

    DEFF Research Database (Denmark)

    Voigt, Andreas Jauernik; Mandrup-Poulsen, Christian; Nielsen, Kenny Krogh

    2016-01-01

    of the subsea installed rotating machinery. It is well known that careful design of turbomachinery seals, such as interstage and balance piston seals, is pivotal for the performance of pumps and compressors. Consequently, the ability to predict the complex interaction between fluid dynamics and rotordynamics...... University of Denmark and Lloyd's Register Consulting are currently establishing a purpose built state of the art multiphase seal test facility, which is divided into three modules. Module I consists of a full scale Active Magnetic Bearing (AMB) based rotor dynamic test bench. The internally designed custom...... AMBs are equipped with an embedded Hall sensor system enabling high precision non-contact seal force quantification. Module II is a fully automatised calibration facility for the Hall sensor based force quantification system. Module III consists of the test seal housing assembly. This paper provides...

  17. Cost saving synergistic shaft seal

    Science.gov (United States)

    Ludwig, L. P.; Strom, T. N.

    1976-01-01

    Segmented carbon rings, used to replace elastomeric seal lip, provide resistance to high temperatures generated in lubricating film. Machining and close manufacturing tolerances of conventional segmented seal are avoided by mounting segmented rings in elastomeric flex section.

  18. Development of a ceramic tamper indicating seal: SRNL contributions

    International Nuclear Information System (INIS)

    Krementz, Dan; Brinkman, Kyle S.; Martinez-Rodriguez, Michael J.; Mendez-Torres, Adrian E.; Weeks, George E.

    2013-01-01

    Savannah River National Laboratory (SRNL) and Sandia National Laboratories (SNL) are collaborating on development of a Ceramic Seal, also sometimes designated the Intrinsically Tamper Indicating Ceramic Seal (ITICS), which is a tamper indicating seal for international safeguards applications. The Ceramic Seal is designed to be a replacement for metal loop seals that are currently used by the IAEA and other safeguards organizations. The Ceramic Seal has numerous features that enhance the security of the seal, including a frangible ceramic body, protective and tamper indicating coatings, an intrinsic unique identifier using Laser Surface Authentication, electronics incorporated into the seal that provide cryptographic seal authentication, and user-friendly seal wire capture. A second generation prototype of the seal is currently under development whose seal body is of Low Temperature Co-fired Ceramic (LTCC) construction. SRNL has developed the mechanical design of the seal in an iterative process incorporating comments from the SNL vulnerability review team. SRNL is developing fluorescent tamper indicating coatings, with recent development focusing on optimizing the durability of the coatings and working with a vendor to develop a method to apply coatings on a 3-D surface. SRNL performed a study on the effects of radiation on the electronics of the seal and possible radiation shielding techniques to minimize the effects. SRNL is also investigating implementation of Laser Surface Authentication (LSA) as a means of unique identification of each seal and the effects of the surface coatings on the LSA signature.

  19. DEVELOPMENT OF A CERAMIC TAMPER INDICATING SEAL: SRNL CONTRIBUTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Krementz, D.; Brinkman, K.; Martinez-Rodriguez, M.; Mendez-Torres, A.; Weeks, G.

    2013-06-03

    Savannah River National Laboratory (SRNL) and Sandia National Laboratories (SNL) are collaborating on development of a Ceramic Seal, also sometimes designated the Intrinsically Tamper Indicating Ceramic Seal (ITICS), which is a tamper indicating seal for international safeguards applications. The Ceramic Seal is designed to be a replacement for metal loop seals that are currently used by the IAEA and other safeguards organizations. The Ceramic Seal has numerous features that enhance the security of the seal, including a frangible ceramic body, protective and tamper indicating coatings, an intrinsic unique identifier using Laser Surface Authentication, electronics incorporated into the seal that provide cryptographic seal authentication, and user-friendly seal wire capture. A second generation prototype of the seal is currently under development whose seal body is of Low Temperature Co-fired Ceramic (LTCC) construction. SRNL has developed the mechanical design of the seal in an iterative process incorporating comments from the SNL vulnerability review team. SRNL is developing fluorescent tamper indicating coatings, with recent development focusing on optimizing the durability of the coatings and working with a vendor to develop a method to apply coatings on a 3-D surface. SRNL performed a study on the effects of radiation on the electronics of the seal and possible radiation shielding techniques to minimize the effects. SRNL is also investigating implementation of Laser Surface Authentication (LSA) as a means of unique identification of each seal and the effects of the surface coatings on the LSA signature.

  20. Effect of reciprocating systems and working lengths on apical microcrack development: a micro-CT Study

    International Nuclear Information System (INIS)

    Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes; Heck, Richard John

    2017-01-01

    The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 μm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation. (author)

  1. Effect of reciprocating systems and working lengths on apical microcrack development: a micro-CT Study

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes, E-mail: bruna_paloma@msn.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Heck, Richard John [Department of Land Resource Science, University of Guelph (Canada)

    2017-11-15

    The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 μm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation. (author)

  2. Basolateral cholesterol depletion alters Aquaporin-2 post-translational modifications and disrupts apical plasma membrane targeting.

    Science.gov (United States)

    Moeller, Hanne B; Fuglsang, Cecilia Hvitfeldt; Pedersen, Cecilie Nøhr; Fenton, Robert A

    2018-01-01

    Apical plasma membrane accumulation of the water channel Aquaporin-2 (AQP2) in kidney collecting duct principal cells is critical for body water homeostasis. Posttranslational modification (PTM) of AQP2 is important for regulating AQP2 trafficking. The aim of this study was to determine the role of cholesterol in regulation of AQP2 PTM and in apical plasma membrane targeting of AQP2. Cholesterol depletion from the basolateral plasma membrane of a collecting duct cell line (mpkCCD14) using methyl-beta-cyclodextrin (MBCD) increased AQP2 ubiquitylation. Forskolin, cAMP or dDAVP-mediated AQP2 phosphorylation at Ser269 (pS269-AQP2) was prevented by cholesterol depletion from the basolateral membrane. None of these effects on pS269-AQP2 were observed when cholesterol was depleted from the apical side of cells, or when MBCD was applied subsequent to dDAVP stimulation. Basolateral, but not apical, MBCD application prevented cAMP-induced apical plasma membrane accumulation of AQP2. These studies indicate that manipulation of the cholesterol content of the basolateral plasma membrane interferes with AQP2 PTM and subsequently regulated apical plasma membrane targeting of AQP2. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Improved sealing for in-core systems

    International Nuclear Information System (INIS)

    Dunford, S.

    1989-01-01

    The in-core instrumentation sealing nozzles designed by Framatome have three mechanical seals in series instead of the one traditional seal, and are pressurized by simply tightening up the nozzle covers. They have been installed from the start on all Framatome PWRs, as well as having been backfitted on Belgium and Yugoslavian units and chosen for the Chinese Qinshan plant. (author)

  4. The impact of glide phases on the trackability of hydrodynamic trails in harbour seals (Phoca vitulina).

    Science.gov (United States)

    Wieskotten, S; Dehnhardt, G; Mauck, B; Miersch, L; Hanke, W

    2010-11-01

    The mystacial vibrissae of harbour seals (Phoca vitulina) constitute a highly sensitive hydrodynamic receptor system enabling the seals to detect and follow hydrodynamic trails. In the wild, hydrodynamic trails, as generated by swimming fish, consist of cyclic burst-and-glide phases, associated with various differences in the physical parameters of the trail. Here, we investigated the impact of glide phases on the trackability of differently aged hydrodynamic trails in a harbour seal. As fish are not easily trained to swim certain paths with predetermined burst-and-glide phases, the respective hydrodynamic trails were generated using a remote-controlled miniature submarine. Gliding phases in hydrodynamic trails had a negative impact on the trackability when trails were 15 s old. The seal lost the generated trails more often within the transition zones, when the submarine switched from a burst to a glide moving pattern. Hydrodynamic parameter analysis (particle image velocimetry) revealed that the smaller dimensions and faster decay of hydrodynamic trails generated by the gliding submarine are responsible for the impaired success of the seal tracking the gliding phase. Furthermore, the change of gross water flow generated by the submarine from a rearwards-directed stream in the burst phase to a water flow passively dragged behind the submarine during gliding might influence the ability of the seal to follow the trail as this might cause a weaker deflection of the vibrissae. The possible ecological implications of intermittent swimming behaviour in fish for piscivorous predators are discussed.

  5. Antimicrobial photodynamic therapy for the treatment of teeth with apical periodontitis: a histopathological evaluation.

    Science.gov (United States)

    Silva, Lea Assed Bezerra; Novaes, Arthur B; de Oliveira, Rafael R; Nelson-Filho, Paulo; Santamaria, Milton; Silva, Raquel Assed Bezerra

    2012-03-01

    This study evaluated the in vivo response of apical and periapical tissues of dogs' teeth with apical periodontitis after one-session endodontic treatment with and without antimicrobial photodynamic therapy (aPDT). Sixty root canals with experimentally induced apical periodontitis were instrumented and assigned to 4 groups receiving aPDT and root canal filling (RCF) or not: group aPDT+/RCF+ (n = 20): aPDT (photosensitizer phenothiazine chloride at 10 mg/mL for 3 minutes and diode laser [λ = 660 nm, 60 mW/cm(2)] for 1 minute) and RCF in the same session; group aPDT+/RCF- (n = 10); group aPDT-/RCF+ (n = 20), and group aPDT-/RCF- (n = 10). Teeth were restored, and the animals were killed after 90 days. Sections from the maxillas and mandibles were stained with hematoxylin-eosin and Mallory trichrome and examined under light microscopy. Descriptive (ie, newly formed apical mineralized tissue, periapical inflammatory infiltrate, apical periodontal ligament thickness, and mineralized tissue resorption) and quantitative (ie, periapical lesion size and number of inflammatory cells) microscopic analysis was performed. Quantitative data were analyzed by the Kruskal-Wallis and Dunn tests (α = .05). In the aPDT-treated groups, the periapical region was moderately/severely enlarged with no inflammatory cells, moderate neoangiogenesis and fibrogenesis, and the smallest periapical lesions. Although apical closure by mineralized tissue deposition was not achieved, the absence of inflammatory cells, moderate neoangiogenesis, and fibrogenesis in the periapical region in the groups treated with aPDT indicate that this can be a promising adjunct therapy to cleaning and shaping procedures in teeth with apical periodontitis undergoing one-session endodontic treatment. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Multi-Canister overpack sealing configuration

    International Nuclear Information System (INIS)

    SMITH, K.E.

    1998-01-01

    The Spent Nuclear Fuel (SNF) position regarding the Multi-Canister Overpack (MCO) sealing configuration is to initially rely on an American Society of Mechanical Engineers (ASME) Section III Subsection NB code compliant mechanical closure/sealing system to quickly and safely establish and maintain full confinement of radioactive materials prior to and during MCO fuel drying activities. Previous studies have shown the mechanical seal to be the preferred closure method, based on dose, cost, and schedule considerations. The cost and schedule impacts of redesigning the mechanical closure to a welded shield plug do not support changing the closure system. The SNF Project has determined that the combined mechanical/welded closure system meets or exceeds the regulatory requirements to provide redundant seals while accommodating key safety and schedule limitations that are unique to K Basins fuel removal effort

  7. Coupled processes in repository sealing

    International Nuclear Information System (INIS)

    Case, J.B.; Kelsall, P.C.

    1985-01-01

    The significance of coupled processes in repository sealing is evaluated. In most repository designs, shaft seals will be located in areas of relatively low temperature perturbation, in which case the coupling of temperature with stress and permeability may be less significant than the coupling between stress and permeability that occurs during excavation. Constitutive relationships between stress and permeability are reviewed for crystalline rock and rocksalt. These provide a basis for predicting the development of disturbed zones near excavations. Field case histories of the degree of disturbance are presented for two contrasting rock types - Stripa granite and Southeastern New Mexico rocksalt. The results of field investigations in both rock types confirm that hydraulic conductivity or permeability is stress dependent, and that shaft seal performance may be related to the degree that stresses are perturbed and restored near the seal

  8. Sealing glasses for titanium and titanium alloys

    Science.gov (United States)

    Brow, Richard K.; McCollister, Howard L.; Phifer, Carol C.; Day, Delbert E.

    1997-01-01

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B.sub.2 O.sub.3), barium oxide (BaO), lanthanum oxide (La.sub.2 O.sub.3), and at least one other oxide selected from the group consisting of aluminum oxide (Al.sub.2 O.sub.3), calcium oxide (CaO), lithium oxide (Li.sub.2 O), sodium oxide (Na.sub.2 O), silicon dioxide (SiO.sub.2), or titanium dioxide (TiO.sub.2). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansion about that of titanium or titanium alloys, and with sealing temperatures less than about 900.degree. C., and generally about 700.degree.-800.degree. C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps).

  9. Apical extrusion of debris in primary molar root canals using mechanical and manual systems.

    Science.gov (United States)

    Buldur, B; Hascizmeci, C; Aksoy, S; Nur Aydin, M; Guvendi, O N

    2018-03-01

    Apical extrusion of debris in primary root canal treatment has not been well elucidated. The purpose of this study is to compare the amount of apically extruded debris during the preparation of primary molar root canals using ProTaper, ProTaper Next, Self-adjusting File (SAF) and hand files. One hundred sixty extracted primary mandibular molar teeth were assigned to 2 groups: Group 1: Resorbed (n=80) and Group 2: Non-resorbed (n=80) and randomly to four subgroups (n=20 teeth for each subgroup) according to the instruments used, ProTaper, ProTaper Next, SAF, and hand file. The apically extruded debris was collected and dried in preweighed Eppendof tubes. The dry weight was calculated by subtracting the preoperative weight from the postoperative weight. Data were analysed statistically using the ANOVA and the Bonferroni post hoc t-test. The amount of apically extruded debris was significantly less for the non-resorbed group compared to the resorbed group (PProTaper Next and SAF extruded significantly less debris than did the ProTaper and hand files (PProTaper Next and SAF (P>0.05). All instruments caused apically extruded debris in primary teeth.

  10. Development of Advanced Carbon Face Seals for Aircraft Engines

    Science.gov (United States)

    Falaleev, S. V.; Bondarchuk, P. V.; Tisarev, A. Yu

    2018-01-01

    Modern aircraft gas turbine engines require the development of seals which can operate for a long time with low leakages. The basic type of seals applied for gas turbine engine rotor supports is face seal. To meet the modern requirements of reliability, leak-tightness and weight, low-leakage gas-static and hydrodynamic seals have to be developed. Dry gas seals use both gas-static and hydrodynamic principles. In dry gas seals microgrooves are often used, which ensure the reverse injection of leakages in the sealed cavity. Authors have developed a calculation technique including the concept of coupled hydrodynamic, thermal and structural calculations. This technique allows to calculate the seal performance taking into account the forces of inertia, rupture of the lubricant layer and the real form of the gap. Authors have compared the efficiency of seals with different forms of microgrooves. Results of calculations show that seal with rectangular form of microgrooves has a little gap leading to both the contact of seal surfaces and the wear. Reversible microgrooves have a higher oil mass flow rate, whereas HST micro-grooves have good performance, but they are difficult to produce. Spiral microgrooves have both an acceptable leakages and a high stiffness of liquid layer that is important in terms of ensuring of sealing performance at vibration conditions. Therefore, the spiral grooves were chosen for the developed seal. Based on calculation results, geometric dimensions were chosen to ensure the reliability of the seal operation by creating a guaranteed liquid film, which eliminates the wear of the sealing surfaces. Seals designed were tested both at the test rig and in the engine.

  11. Reactor coolant pump seals: improving their performance

    International Nuclear Information System (INIS)

    Pothier, N.E.; Metcalfe, R.

    1986-06-01

    Large CANDU plants are benefitting from transient-resistant four-year reliable reactor coolant pump seal lifetimes, a direct result of AECL's 20-year comprehensive seal improvement program involving R and D staff, manufacturers, and plant designers and operators. An overview of this program is presented, which covers seal modification design, testing, post-service examination, specialized maintenance and quality control. The relevancy of this technology to Light Water Reactor Coolant Pump Seals is also discussed

  12. Development of simplified rotating plug seal structure

    International Nuclear Information System (INIS)

    Ueta, M.; Ichimiya, M.; Kanaoka, T.; Sekiya, H.; Ueda, S.; Ishibashi, S.

    1991-01-01

    We studied a compact and simplified rotating plug seal structure and conducted experiments for key elements of the concept such us the mechanical seal structure and sodium deposit prevention system. Good characteristics were confirmed for the mechanical seal structure, which utilizes an elastomer seal and thin lathe bearing. Applicability of the density barrier concept was also confirmed as the sodium deposit prevention system. This concept can be applied to actual plants. (author)

  13. Application study of magnetic fluid seal in hydraulic turbine

    International Nuclear Information System (INIS)

    Yu, Z Y; Zhang, W

    2012-01-01

    The waterpower resources of our country are abundant, and the hydroelectric power is developed, but at present the main shaft sealing device of hydraulic turbine is easy to wear and tear and the leakage is great. The magnetic fluid seal has the advantages of no contact, no wear, self-healing, long life and so on. In this paper, the magnetic fluid seal would be used in the main shaft of hydraulic turbine, the sealing structure was built the model, meshed the geometry, applied loads and solved by using MULTIPHYSICS in ANSYS software, the influence of the various sealing structural parameters such as tooth width, height, slot width, sealing gap on the sealing property were analyzed, the magnetic fluid sealing device suitable for large-diameter shaft and sealing water was designed, the sealing problem of the hydraulic turbine main shaft was solved effectively which will bring huge economic benefits.

  14. Sealing apparatus for airfoils of gas turbine engines

    Science.gov (United States)

    Jones, R.B.

    1998-05-19

    An improved airfoil tip sealing apparatus is disclosed wherein brush seals are attached to airfoil tips with the distal ends of the brush seal fibers sealingly contacting opposing wall surfaces. Embodiments for variable vanes, stators and both cooled and uncooled turbine blade applications are disclosed. 17 figs.

  15. Reactor coolant pump shaft seal stability during station blackout

    International Nuclear Information System (INIS)

    Rhodes, D.B.; Hill, R.C.; Wensel, R.G.

    1987-05-01

    Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries

  16. Reactor coolant pump shaft seal stability during station blackout

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, D B; Hill, R C; Wensel, R G

    1987-05-01

    Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries.

  17. Polymer nanocomposites for sealing microannulus cracks in wellbores cement-steel interface

    Science.gov (United States)

    Genedy, M.; Fernandez, S. G.; Stormont, J.; Matteo, E. N.; Dewers, T. A.; Reda Taha, M.

    2017-12-01

    Seal integrity of production and storage wellbores has become a critical challenge with the increasing oil and gas leakage incidents. The general consensus is that one of the potential leakage pathways is micro-annuli at the cement-steel interface. In this paper, we examine the efficiency of proposed polymer nanocomposite to seal microannulus cracks at the cement-steel interface. The repair material efficiency is defined as the ability of the repair material to reduce or eliminate the gas permeability of the cement-steel interface. The flow rate of an inert gas (Nitrogen) at the cement-steel interface was investigated for three cases: 1) repaired test samples with traditional repair material (microfine cement), 2) polymer nanocomposites, and 3) unrepaired test samples. Flow rates were measured and compared for all three cases. The experimental results show up to 99.5% seal efficiency achieved by using polymer nanocomposites compared to 20% efficiency achieved in the case of microfine cement. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525. SAND2017-8094 A.

  18. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  19. Decreased Expression of Semaphorin3A/Neuropilin-1 Signaling Axis in Apical Periodontitis

    Directory of Open Access Journals (Sweden)

    Ying Lin

    2017-01-01

    Full Text Available Apical periodontitis (AP is a chronic infection of endodontic origin accompanied with bone destruction around the apical region. Semaphorin3A (Sema3A and neuropilin-1 (Nrp1 are regarded as a pair of immune regulators in bone metabolism. In this study, we firstly investigated the expression pattern of Sema3A/Nrp1 in apical periodontitis and its correlation with bone destruction. Using rat animal model, we analysed the level of mandibular bone destruction and the expression of Sema3A/Nrp1 on days 0, 7, 14, 21, 28, and 35 after pulp exposure. In addition, clinical samples from apical periodontitis patients were obtained to analyse the expression of Sema3A/Nrp1. These results indicated that the bone destruction level expanded from days 7 to 35. The number of positive cells and level of mRNA expression of Sema3A/Nrp1 were significantly decreased from days 7 to 35, with a negative correlation with bone destruction. Moreover, expression of Sema3A/Nrp1 in the AP group was reduced compared to the control group of clinical samples. In conclusion, decreased expression of Sema3A/Nrp1 was observed in periapical lesions and is potentially involved in the bone resorption of the periapical area, suggesting that Sema3A/Nrp1 may contribute to the pathological development of apical periodontitis.

  20. Strategies to reduce the apical necrosis in vitro multiplication and rooting of Pistachio

    Directory of Open Access Journals (Sweden)

    Mariela Cid

    2016-07-01

    Full Text Available The pistachio (Pistacia sp. is one of the least exploited fruit among the main causes is the high cost of plant material by the difficulties of propagation of the species. The propagation in vitro offers great potential for the industry of this species by multiplication scale of selected clones. The aim of this study was to control the apical necrosis of outbreaks in the in vitro propagation Pistachio. From young shoots of plants of this species kept in growing houses, proceeded to disinfection with sodium hypochlorite 1% for different times. The apical and axillary buds were established in the culture medium Murashige and Skoog (1962 modified and supplemented with 1 mg/L Metatopolina. Different types of bottles, number and type of explants and culture media formulations for two subcultures multiplication and rooting were evaluated. Glass flask of 200 ml capacity, and line proliferates DKW medium achieved the lowest values apical necrosis. In the multiplication phase values were low in all treatments tested no statistical difference between them compared to rooting where apical necrosis reached higher values. The average DKW and prolific lines obtained lower values. MS medium modified crop, favored the number of segments rooted and DKW (Driver and Kuniyuki, 1984 the number of segments that sprouted, the latter having lower incidence of apical necrosis.

  1. Solid oxide fuel cell having a glass composite seal

    Science.gov (United States)

    De Rose, Anthony J.; Mukerjee, Subhasish; Haltiner, Jr., Karl Jacob

    2013-04-16

    A solid oxide fuel cell stack having a plurality of cassettes and a glass composite seal disposed between the sealing surfaces of adjacent cassettes, thereby joining the cassettes and providing a hermetic seal therebetween. The glass composite seal includes an alkaline earth aluminosilicate (AEAS) glass disposed about a viscous glass such that the AEAS glass retains the viscous glass in a predetermined position between the first and second sealing surfaces. The AEAS glass provides geometric stability to the glass composite seal to maintain the proper distance between the adjacent cassettes while the viscous glass provides for a compliant and self-healing seal. The glass composite seal may include fibers, powders, and/or beads of zirconium oxide, aluminum oxide, yttria-stabilized zirconia (YSZ), or mixtures thereof, to enhance the desirable properties of the glass composite seal.

  2. Determination of apical constriction and apical foramen using electronic apex locator in vivo: Comparison between vital and nonvital teeth

    Directory of Open Access Journals (Sweden)

    Gaurav Aggarwal

    2018-01-01

    Conclusion: The study supports that EAL measures the location of AC and apical foramen with similar accuracy in vital and nonvital teeth. Furthermore, the distance between the two is reliable when compared with the actual distance observed under stereomicroscope supporting its widespread usage in clinical endodontics.

  3. Piston rod seal for a Stirling engine

    Science.gov (United States)

    Shapiro, Wilbur

    1984-01-01

    In a piston rod seal for a Stirling engine, a hydrostatic bearing and differential pressure regulating valve are utilized to provide for a low pressure differential across a rubbing seal between the hydrogen and oil so as to reduce wear on the seal.

  4. Folded membrane dialyzer with mechanically sealed edges

    Energy Technology Data Exchange (ETDEWEB)

    Markley, F.W.

    A semipermeable membrane is folded in accordion fashion to form a stack of pleats and the edges are sealed so as to isolate the opposite surfaces of the membrane. The stack is contained within a case that provides ports for flow of blood in contact with one surface of the membrane through channels formed by the pleats and also provides ports for flow of a dialysate through channels formed by the pleats in contact with the other surface of the membrane. The serpentine side edges of the membrane are sealed by a solidified plastic material, whereas effective mechanical means are provided to seal the end edges of the folded membrane. The mechanical means include a clamping strip which biases case sealing flanges into a sealed relationship with end portions of the membrane near the end edges, which portions extend from the stack and between the sealing flanges.

  5. 30 CFR 75.337 - Construction and repair of seals.

    Science.gov (United States)

    2010-07-01

    ... sealed areas. (b) Prior to sealing, the mine operator shall— (1) Remove insulated cables, batteries, and other potential electric ignition sources from the area to be sealed when constructing seals, unless it... after April 18, 2008, the seal at the lowest elevation shall have a corrosion-resistant, non-metallic...

  6. Correlation between prostate brachytherapy-related urethral stricture and peri-apical urethral dosimetry: A matched case–control study

    International Nuclear Information System (INIS)

    Earley, James J.; Abdelbaky, Ather M.; Cunningham, Melanie J.; Chadwick, Eliot; Langley, Stephen E.M.; Laing, Robert W.

    2012-01-01

    Background and purpose: Radiation dose to the bulbomembranous urethra has been shown to correlate with urethral stricture formation. This retrospective case–control study was designed to explore the relationship between dose to the apical/peri-apical regions of the urethra and development of brachytherapy (BXT)-related urethral stricture. Materials and methods: Cases were patients who developed urethral stricture after treatment with BXT as monotherapy and who had urethral dosimetry post-implant. Each case was matched with a control that had not developed urethral stricture. Dosimetry was compared between cases and controls. Results: Twenty-three cases were pair matched with 23 controls. There were no significant differences between the two groups in terms of age, presenting Prostate Specific Antigen (PSA), International Prostate Symptom Score (IPSS) or Gleason score. The dose delivered to the peri-apical and apical urethra was significantly higher for cases when compared with controls (peri-apical urethra: mean V 150 1.1 Vs 0.8 cc [p = 0.02]; apical urethra: mean dose 200 Vs 174 Gy [p = 0.01]). The distance from the prostate apex to isodose lines was also found to be significant in predicting stricture formation. Conclusion: There was evidence to suggest that the development of BXT-related stricture was associated with radiation dose at the apical and peri-apical urethra. Attention to the dose delivered to those areas may minimise the risk of developing such morbidity.

  7. Through-flow of water in leaves of a submerged plant is influenced by the apical opening

    DEFF Research Database (Denmark)

    Pedersen, Ole; Jørgensen, Lise Bolt; Sand-Jensen, Kaj

    1997-01-01

    Submerged plant, apical opening, hydathode, Sparganium, hydraulic architecture, leaf specific conductivity......Submerged plant, apical opening, hydathode, Sparganium, hydraulic architecture, leaf specific conductivity...

  8. Data report on the Waste Isolation Pilot Plant Small-Scale Seal Performance Test, Series F grouting experiment

    International Nuclear Information System (INIS)

    Ahrens, E.H.; Dale, T.F.; Van Pelt, R.S.

    1996-03-01

    SSSPT-F was designed to evaluate sealing materials at WIPP. It demonstrated: (1) the ability to practically and consistently produce ultrafine cementitious grout at the grouting site, (2) successful, consistent, and efficient injection and permeation of the grout into fractured rock at the repository horizon, (3) ability of the grout to penetrate and seal microfractures, (4) procedures and equipment used to inject the grout. Also techniques to assess the effectiveness of the grout in reducing the gas transmissivity of the fractured rock were evaluated. These included gas-flow/tracer testing, post-grout coring, pre- and post-grout downhole televiewer logging, slab displacement measurements, and increased loading on jacks during grout injection. Pre- and post-grout diamond drill core was obtained for use in ongoing evaluations of grouting effectiveness, degradation, and compatibility. Diamond drill equipment invented for this test successfully prevented drill cuttings from plugging fractures in grout injection holes

  9. Data report on the Waste Isolation Pilot Plant Small-Scale Seal Performance Test, Series F grouting experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, E.H. [Sandia National Labs., Albuquerque, NM (United States); Dale, T.F.; Van Pelt, R.S. [INTERA, Inc., Austin, TX (United States)

    1996-03-01

    SSSPT-F was designed to evaluate sealing materials at WIPP. It demonstrated: (1) the ability to practically and consistently produce ultrafine cementitious grout at the grouting site, (2) successful, consistent, and efficient injection and permeation of the grout into fractured rock at the repository horizon, (3) ability of the grout to penetrate and seal microfractures, (4) procedures and equipment used to inject the grout. Also techniques to assess the effectiveness of the grout in reducing the gas transmissivity of the fractured rock were evaluated. These included gas-flow/tracer testing, post-grout coring, pre- and post-grout downhole televiewer logging, slab displacement measurements, and increased loading on jacks during grout injection. Pre- and post-grout diamond drill core was obtained for use in ongoing evaluations of grouting effectiveness, degradation, and compatibility. Diamond drill equipment invented for this test successfully prevented drill cuttings from plugging fractures in grout injection holes.

  10. Liquid-metal dip seal with pneumatic spring

    International Nuclear Information System (INIS)

    Poindexter, A.M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal

  11. Experimental toxoplasma gondii infection in grey seals (Halichoerus grypus)

    DEFF Research Database (Denmark)

    Gajadhar, A. A.; Measures, L.; Forbes, L. B.

    2004-01-01

    Laboratory-reared animals were used to assess the susceptibility of seals (Halichoerus grypus) to Toxoplasma gondii infection. Four seals were each orally inoculated with 100 or 10,000 oocysts of T. gondii (VEG strain), and another 4 seals served as negative controls. Occasionally, mild behavioral...... changes were observed in all inoculated seals but not in control animals. A modified agglutination test revealed the presence of antibodies to T. gondii in sera collected from inoculated seals and mice inoculated as controls. No evidence of the parasite was found on an extensive histological examination...... of seal tissues, and immunohistochemical staining of tissue sections from inoculated seals revealed a single tissue cyst in only 1 seal. Control mice inoculated with 10 oocysts from the same inoculum given to seals became serologically and histologically positive for T. gondii. Cats that were fed brain...

  12. Root canal microbiota of teeth with chronic apical periodontitis.

    Science.gov (United States)

    Rôças, I N; Siqueira, J F

    2008-11-01

    Samples from infected root canals of 43 teeth with chronic apical periodontitis were analyzed for the presence and relative levels of 83 oral bacterial species and/or phylotypes using a reverse-capture checkerboard hybridization assay. Associations between the most frequently detected taxa were also recorded. The most prevalent taxa were Olsenella uli (74%), Eikenella corrodens (63%), Porphyromonas endodontalis (56%), Peptostreptococcus anaerobius (54%), and Bacteroidetes oral clone X083 (51%). When prevalence was considered only for bacteria present at levels >10(5), Bacteroidetes clone X083 was the most frequently isolated bacterium (37%), followed by Parvimonas micra (28%), E. corrodens (23%), and Tannerella forsythia (19%). The number of target taxa per canal was directly proportional to the size of the apical periodontitis lesion, with lesions >10 mm in diameter harboring a mean number of approximately 20 taxa. Several positive associations for the most prevalent taxa were disclosed for the first time and may have important ecological and pathogenic implications. In addition to strengthening the association of several cultivable named species with chronic apical periodontitis, the present findings using a large-scale analysis allowed the inclusion of some newly named species and as-yet-uncultivated phylotypes in the set of candidate pathogens associated with this disease.

  13. Low torque hydrodynamic lip geometry for rotary seals

    Science.gov (United States)

    Dietle, Lannie L.; Schroeder, John E.

    2015-07-21

    A hydrodynamically lubricating geometry for the generally circular dynamic sealing lip of rotary seals that are employed to partition a lubricant from an environment. The dynamic sealing lip is provided for establishing compressed sealing engagement with a relatively rotatable surface, and for wedging a film of lubricating fluid into the interface between the dynamic sealing lip and the relatively rotatable surface in response to relative rotation that may occur in the clockwise or the counter-clockwise direction. A wave form incorporating an elongated dimple provides the gradual convergence, efficient impingement angle, and gradual interfacial contact pressure rise that are conducive to efficient hydrodynamic wedging. Skewed elevated contact pressure zones produced by compression edge effects provide for controlled lubricant movement within the dynamic sealing interface between the seal and the relatively rotatable surface, producing enhanced lubrication and low running torque.

  14. Turbine and Structural Seals Team Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — Seals Team Facilities conceive, develop, and test advanced turbine seal concepts to increase efficiency and durability of turbine engines. Current projects include...

  15. Tamper-indicating devices and safeguards seals evaluation test report

    International Nuclear Information System (INIS)

    Horton, P.R.V.; Waddoups, I.G.

    1993-12-01

    Sandia National Laboratories was asked to evaluate the seals used as tamper-indicating devices (TIDs) at DOE facilities. Initially, a survey determined what seal manufacturers were being used and what similar seal types were available. Once the required specifications for TIDs were defined, a test plan measured the currently available seals against the requirements. Environmental and physical type tests stressed the seals under two broad categories: (1) handling durability and (2) tamper resistance. Results of the testing provide comparative ratings for the various seals, recommendations for using currently available seals, and a new tamper-indicating technology

  16. Prevalence, clinical significance, and natural history of left ventricular apical aneurysms in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Maron, Martin S; Finley, John J; Bos, J Martijn; Hauser, Thomas H; Manning, Warren J; Haas, Tammy S; Lesser, John R; Udelson, James E; Ackerman, Michael J; Maron, Barry J

    2008-10-07

    Hypertrophic cardiomyopathy (HCM) is the most common genetic heart disease characterized by a diverse clinical and phenotypic spectrum. This study reports the prevalence, morphology, clinical course, and management of an underrecognized subgroup of HCM patients with left ventricular apical aneurysms. Of 1299 HCM patients, 28 (2%) were identified with left ventricular apical aneurysms, including a pair of identical twins. Aneurysms were recognized at a wide age range (26 to 83 years), including 12 patients (43%) who were rims, and were associated with transmural (and often more extensive) myocardial scarring identified by late gadolinium enhancement cardiovascular magnetic resonance. Apical aneurysms were recognized by echocardiography in only 16 of 28 patients (57%) but by cardiovascular magnetic resonance in the 12 patients undetected by echocardiography. Left ventricular chamber morphology varied; however, 19 patients (68%) showed an "hourglass" contour, with midventricular hypertrophy producing muscular narrowing and intracavitary gradients in 9 patients (74+/-42 mm Hg). Sarcomeric protein missense mutations known to cause other phenotypic expressions of HCM were present in 3 patients. Over 4.1+/-3.7 years of follow-up, 12 patients (43%) with left ventricular apical aneurysms experienced adverse disease complications (event rate, 10.5%/y), including sudden death, appropriate implantable cardioverter-defibrillator discharges, nonfatal thromboembolic stroke, and progressive heart failure and death. Patients with left ventricular apical aneurysms represent an underappreciated subset in the heterogeneous HCM disease spectrum with important clinical implications, often requiring a high index of suspicion and cardiovascular magnetic resonance for identification. Apical aneurysms in HCM are associated with substantial cardiovascular morbidity and mortality and raise novel treatment considerations.

  17. Design and research of seal structure for thermocouple column assembly

    International Nuclear Information System (INIS)

    Rao Qiqi; Li Na; Zhao Wei; Ma Zhigang

    2015-01-01

    The new seal structure was designed to satisfy the function of thermocouple column assembly and the reactor structure. This seal structure uses the packing graphite ring and adopts the self-sealing principle. Cone angle is brought to the seal face of seal structure which is conveniently to assembly and disassembly. After the sealing principle analysis and stress calculation of graphite ring which adopt the cone angle, the cone angle increases the radial force of seal structure and improves the seal effect. The stress analysis result shows the seal structure strength satisfies the regulation requirement. The cold and hot function test results shows the sealing effect is good, and the design requirement is satisfied. (authors)

  18. Evaluation of the distortion rate of panoramic and peri apical radiographs in erupted third molar inclination

    International Nuclear Information System (INIS)

    Ezoddini Ardakani, F.; Zangouie Booshehri, M.; Behniafar, B.

    2011-01-01

    Panoramic and peri apical radiographs are normally used in impacted third molar teeth surgeries. The aim of the present study was to evaluate and compare the distortion of the erupted third molar teeth on panoramic and peri apical radiographs. Patients and Methods: A total of 44 radiographs were obtained of 22 patients (age range, 18-24 years) referred to the faculty of dentistry for orthodontic treatment. A plaster cast was prepared and panoramic radiography was taken for all patients to plan the orthodontic treatment and peri apical radiography was taken for investigation of tooth structure details. Therefore, a total of 66 views and samples were studied by two methods: 1) Measuring the angle between the longitudinal plane of the third molar and occlusal plane. 2) Measuring the angle between the longitudinal plane of second and third molar. Finally, 132 records were evaluated by one individual. Results: There was no significant statistical difference between the mean position of the third molar on panoramic, peri apical radiographs and the casts. However, measurements of the third molars on peri apical radiographs were slightly closer to the measurements of the casts compared to the panoramic radiographs. Conclusion: Distortion does not have a specific effect on the diagnosis of the position of the third erupted molars by peri apical or panoramic radiographs, though various studies have shown that these radiographs have an amount of distortion and peri apical radiographical distortion is less than that in panoramic radiography.

  19. Blunt apical dissection during anatomic radical retropubic prostatectomy

    Directory of Open Access Journals (Sweden)

    Yacoub Saif

    2009-02-01

    Full Text Available Abstract Background Meticulous apical dissection during a radical prostatectomy is imperative to achieve desirable pathologic and quality of life outcomes. Findings We describe a novel technique using careful blunt dissection to better delineate the apex of the prostate, providing a simple means to potentially lessen positive surgical margins at the apex and promote better continence and erectile function in men undergoing an anatomic radical prostatectomy. Median operative time and blood loss were 190 minutes and 675 mL, respectively. Only 10 percent of the patients with positive surgical margins were found to have apical positive surgical margins. Ninety-three percent of patients reported no urinary leakage. Conclusion We believe our technique of isolating the DVC with blunt dissection and then ligating and transecting the DVC to be feasible approach that requires larger studies to truly confirm its utility.

  20. Development of sealing plug for sweep gas line

    International Nuclear Information System (INIS)

    Kikuchi, Taiji; Yamada, Hirokazu; Saitoh, Takashi; Nakamichi, Masaru; Tsuchiya, Kunihiko; Kawamura, Hiroshi

    2004-03-01

    On the irradiation capsule for neutron irradiation test of the tritium breeder, the sealing plug is necessary to prevent a leak of tritium gas when the tritium breeder is picked up from the irradiation capsule after irradiation test. However, the general valve and plug cannot apply to sealing of the sweep gas line because of the following factors, the neutron irradiation effect, limited space in the irradiation capsule, high sealing efficiency, simple method and operation for control. Therefore, the sealing plug for sweep gas line has to be developed. This paper reports the development of the sealing plug for sweep gas line and the operating procedure of the sealing plug in the irradiation capsule. (author)

  1. 2007 NASA Seal/Secondary Air System Workshop. Volume 1

    Science.gov (United States)

    Steinetz, Bruce M.; Hendricks, Robert C.; Delgado, Irebert

    2008-01-01

    The 2007 NASA Seal/Secondary Air System workshop covered the following topics: (i) Overview of NASA's new Orion project aimed at developing a new spacecraft that will fare astronauts to the International Space Station, the Moon, Mars, and beyond; (ii) Overview of NASA's fundamental aeronautics technology project; (iii) Overview of NASA Glenn s seal project aimed at developing advanced seals for NASA's turbomachinery, space, and reentry vehicle needs; (iv) Reviews of NASA prime contractor, vendor, and university advanced sealing concepts, test results, experimental facilities, and numerical predictions; and (v) Reviews of material development programs relevant to advanced seals development. Turbine engine studies have shown that reducing seal leakage as well as high-pressure turbine (HPT) blade tip clearances will reduce fuel burn, lower emissions, retain exhaust gas temperature margin, and increase range. Turbine seal development topics covered include a method for fast-acting HPT blade tip clearance control, noncontacting low-leakage seals, intershaft seals, and a review of engine seal performance requirements for current and future Army engine platforms.

  2. Comparison of correlation algorithms for identifying ultrasonic seals

    International Nuclear Information System (INIS)

    Beer, C.L.; McKenzie, J.M.

    1991-01-01

    Ultrasonic seals are used on reactor fuel assemblies for international safeguards applications. The seals are read by a Seal Pattern Reader to obtain a discrete digital signature that is unique to each seal. The signature is used to determine the identity and integrity of the seals such that accountability and integrity of the nuclear fuel assemblies can be addressed. A correlation coefficient is calculated between the signature obtained at the time of inspection and a stored reference signature, yielding a number between negative one and one. Numbers close to one indicate a high probability that the two signatures represent the same seal. Data from two seals were studied, the Atomic Energy of Canada Limited Random Coil (ARC) seal and the JRC-Ispra VAK-III seal. Currently, correlation coefficients are obtained using data in the time or spatial domain, respectively. An approach is proposed in which the correlation coefficients are obtained from the Fourier transforms of the data. This paper reports that the objective of the study was to perform independent experiments on available ARC and VAK-III data to determine the advantages, if any, of transforming the data to the frequency spectrum prior to performing the correlation calculation. The results indicate definite advantages can be obtained

  3. Effect of sealing on the morphology of anodized aluminum oxide

    International Nuclear Information System (INIS)

    Hu, Naiping; Dong, Xuecheng; He, Xueying; Browning, James F.; Schaefer, Dale W.

    2015-01-01

    Highlights: • We explored structural change of anodizing aluminum oxide induced by sealing. • All sealing methods decrease pore size as shown by X-ray/neutron scattering. • Cold sealing and hot water sealing do not alter the aluminum oxide framework. • Hot nickel acetate sealing both fills the pores and deposits on air oxide interface. • Samples with hot nickel acetate sealing outperform other sealing methods. - Abstract: Ultra-small angle X-ray scattering (USAXS), small-angle neutron scattering (SANS), X-ray reflectometry (XRR) and neutron reflectometry (NR) were used to probe structure evolution induced by sealing of anodized aluminum. While cold nickel acetate sealing and hot-water sealing decrease pore size, these methods do not alter the cylindrical porous framework of the anodic aluminum oxide layer. Hot nickel acetate both fills the pores and deposits on the air surface (air–oxide interface), leading to low porosity and small mean pore radius (39 Å). Electrochemical impedance spectroscopy and direct current polarization show that samples sealed by hot nickel acetate outperform samples sealed by other sealing methods

  4. Vaccination of harbour seals (Phoca vitulina) against phocid distemper with two different inactivated canine distemper virus (CDV) vaccines.

    NARCIS (Netherlands)

    I.K.G. Visser (Ilona); M.W.G. van de Bildt (Marco); H.N. Brugge; P.J.H. Reijnders; E.J. Vedder (Lies); J. Kuiper; P. de Vries (Petra); J. Groen (Jan); H.C. Walvoort; F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1989-01-01

    textabstractTwo inactivated canine distemper virus (CDV) vaccines--an adjuvanted whole inactivated virus and a subunit ISCOM preparation--were tested for their ability to induce protective immunity in harbour seals (Phoca vitulina) against phocid distemper, a disease that recently killed greater

  5. Ergonomics and safety of manual bag sealing.

    NARCIS (Netherlands)

    Groot, M.D. de; Bosch, T.; Eikhout, S.M.; Vink, P.

    2005-01-01

    A variety of seals is used to close bags. Each seal has advantages and disadvantages. For shop assistants sealing bags could be a repetitive physically demanding action. Opening and closing the bags again can cause some discomfort or annoyance for consumers. Besides, it is an activity which can

  6. Cannula has lip seal movingly coupled to proximal section, to facilitate relative movement of instrument shaft between seal and proximal section and to maintain sealing engagement between shaft and proximal portion

    OpenAIRE

    Bonadio, Frank; Vaugh, Trevor

    2007-01-01

    The cannula (1) has an instrument insertion section (3) and a tube (2) with an access channel (7) for extension of an instrument. A lip seal (4) movingly couples to a proximal section to engage with an instrument shaft (5). The seal facilitates a lateral movement of the instrument, and maintains the sealing engagement between the seal and the instrument shaft. A coupling portion made of gelatinous elastomeric material with plasticizer consisting of naturally derived oils, synthetic oils and l...

  7. Dampers for Stationary Labyrinth Seals

    Science.gov (United States)

    El-Aini, Yehia; Mitchell, William; Roberts, Lawrence; Montgomery, Stuart; Davis, Gary

    2011-01-01

    Vibration dampers have been invented that are incorporated as components within the stationary labyrinth seal assembly. These dampers are intended to supplement other vibration-suppressing features of labyrinth seals in order to reduce the incidence of high-cycle-fatigue failures, which have been known to occur in the severe vibratory environments of jet engines and turbopumps in which labyrinth seals are typically used. A vibration damper of this type includes several leaf springs and/or a number of metallic particles (shot) all held in an annular seal cavity by a retaining ring. The leaf springs are made of a spring steel alloy chosen, in conjunction with design parameters, to maintain sufficient preload to ensure effectiveness of damping at desired operating temperatures. The cavity is vented via a small radial gap between the retaining ring and seal housing. The damping mechanism is complex. In the case of leaf springs, the mechanism is mainly friction in the slippage between the seal housing and individual dampers. In the case of a damper that contains shot, the damping mechanism includes contributions from friction between individual particles, friction between particles and cavity walls, and dissipation of kinetic energy of impact. The basic concept of particle/shot vibration dampers has been published previously; what is new here is the use of such dampers to suppress traveling-wave vibrations in labyrinth seals. Damping effectiveness depends on many parameters, including, but not limited to, coefficient of friction, mode shape, and frequency and amplitude of vibrational modes. In tests, preloads of the order of 6 to 15 lb (2.72 to 6.8 kilograms) per spring damper were demonstrated to provide adequate damping levels. Effectiveness of shot damping of vibrations having amplitudes from 20 to 200 times normal terrestrial gravitational acceleration (196 to 1,960 meters per square second) and frequencies up to 12 kHz was demonstrated for shot sizes from 0.032 to

  8. In vitro comparison of apical microleakage following canal ...

    African Journals Online (AJOL)

    hope&shola

    2010-11-03

    Nov 3, 2010 ... The purpose of this study was to compare apical microleakage following canal obturation with lateral ..... heat-induced bone tissue injury: A vital microscopic study in the rabbit. J. Prosthet. ... In: Pathways of the Pulp. 9th Ed ...

  9. Safety and effectiveness of repeat arterial closure using the AngioSeal device in patients with hepatic malignancy.

    Science.gov (United States)

    Hieb, Robert A; Neisen, Melissa J; Hohenwalter, Eric J; Molnar, Jim A; Rilling, William S

    2008-12-01

    To retrospectively evaluate the safety and effectiveness of the use of the AngioSeal device for repeat arterial closure in patients with hepatic malignancy. A retrospective analysis of patients with hepatic malignancy who had undergone repeated arterial closure with the AngioSeal device was performed. All charts for patients undergoing transarterial chemoembolization or TheraSphere radioembolization were reviewed for the method of hemostasis and the number of arterial closures. A total of 53 patients (58.5% men, 41.5% women; mean age, 58.7 years) had repeat AngioSeal arterial puncture closure after chemoembolization or TheraSphere treatment. Percutaneous closure of the common femoral artery with the AngioSeal device was performed in accordance with the manufacturer's recommendations. The patients were examined for complications on follow-up. Effectiveness was defined by the ability to obtain satisfactory hemostasis. Safety was assessed by the absence of groin complications and by vessel patency on follow-up angiograms of the puncture site obtained at subsequent liver-directed therapy sessions. Fifty-three patients in this study group had a total of 203 common femoral artery punctures. There were a total of 161 closures with the AngioSeal device (79.3%): 58 (36%) single closures and 103 (64.0%) repeat closures. Of the 161 attempts at AngioSeal closure, there was one closure failure in the single-puncture group, yielding a success rate of 98.3%; and one closure failure in the repeat-puncture group, yielding a success rate of 99%. In these two patients, hemostasis was achieved with traditional manual compression without the need for any other device, and no complications were noted. The overall success rate of AngioSeal device closure was 98.7%. The repeat use of the AngioSeal closure device is safe and effective in patients with hepatic malignancy undergoing regional oncologic interventional procedures.

  10. Ductile alloys for sealing modular component interfaces

    Science.gov (United States)

    Marra, John J.; Wessell, Brian J.; James, Allister W.; Marsh, Jan H.; Gear, Paul J.

    2017-08-08

    A vane assembly (10) having: an airfoil (12) and a shroud (14) held together without metallurgical bonding there between; a channel (22) disposed circumferentially about the airfoil (12), between the airfoil (12) and the shroud (14); and a seal (20) disposed in the channel (22), wherein during operation of a turbine engine having the vane assembly (10) the seal (20) has a sufficient ductility such that a force generated on the seal (20) resulting from relative movement of the airfoil (12) and the shroud (14) is sufficient to plastically deform the seal (20).

  11. Ceramic-glass-metal seal by microwave heating

    Science.gov (United States)

    Meek, Thomas T.; Blake, Rodger D.

    1985-01-01

    A method for producing a ceramic-glass-metal seal by microwaving mixes a slurry of glass sealing material and coupling agent and applies same to ceramic and metal workpieces. The slurry and workpieces are then insulated and microwaved at a power, time and frequency sufficient to cause a liquid phase reaction in the slurry. The reaction of the glass sealing material forms a chemically different seal than that which would be formed by conventional heating because it is formed by diffusion rather than by wetting of the reactants.

  12. Bingham Sealing and Application in Vacuum Clamping

    Science.gov (United States)

    Yao, S. M.; Teo, Wee Kin; Geng, Zunmin; Turner, Sam; Ridgway, Keith

    2011-12-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of "O"ring sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with "O" ring sealing.

  13. Bingham Sealing and Application in Vacuum Clamping

    International Nuclear Information System (INIS)

    Yao, S M; Teo, Wee Kin; Geng Zunmin; Turner, Sam; Ridgway, Keith

    2011-01-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of Or ing sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with 'O' ring sealing.

  14. Tunnel sealing: concept and feasibility evidence

    International Nuclear Information System (INIS)

    Brenner, R.P.; Eppinger, G.; Mettler, K.

    1991-01-01

    This report discusses first the aim and purpose of tunnel seals as well as the requirements which should be satisfied. The basic seal concept is a zoned plug consisting of key zones and intermediate zones. The key zones act as barrier elements and will be placed into sections of competent and sound rock. The main function of the intermediate zones is that of a support and the requirements for sealing efficiency may be somewhat relaxed. Three sealing concepts have been devised for both the key zones and the intermediate zones. They differ in the materials used for the seal and in the placement method. For the key zones highly compacted bentonite is recommended, but also cement-based materials, such as standard concrete or prepact concrete are considered suitable. For the intermediate zones, the use of pumped concrete with subsequent grouting of the roof zone is favourable, but also a combination of concrete with a sand/gravel mixture or with properly compacted excavation material is feasible. The concepts introduced can all be realized by conventional tunnelling methods. Excavation by tunnel boring machine is most advantageous as it minimizes disturbance of the rock caused by the cavity-forming process. By employing simple material models, it can be shown that the depth of the excavation disturbed zone can be minimized if support of the tunnel is provided as early as possible after excavation. The cutting of a groove in the tunnel wall along the key zone can further contribute to reduce the depth of the excavation-disturbed zone. In order to ensure the quality of a seal, the quantities of the materials used can be checked and the work procedures to place the seal can be supervised. For the latter the experiences obtained from a large-scale test should be available. Finally, it is also shown that when considering safety analytical aspects, the proposed sealing concepts represent adequate solutions in spite of the probably increased permeability in the excavation

  15. HMSRP Hawaiian Monk Seal Crittercam video

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with dive...

  16. Pathogenesis of apical periodontitis and the causes of endodontic failures.

    Science.gov (United States)

    Nair, P N R

    2004-11-01

    Apical periodontitis is a sequel to endodontic infection and manifests itself as the host defense response to microbial challenge emanating from the root canal system. It is viewed as a dynamic encounter between microbial factors and host defenses at the interface between infected radicular pulp and periodontal ligament that results in local inflammation, resorption of hard tissues, destruction of other periapical tissues, and eventual formation of various histopathological categories of apical periodontitis, commonly referred to as periapical lesions. The treatment of apical periodontitis, as a disease of root canal infection, consists of eradicating microbes or substantially reducing the microbial load from the root canal and preventing re-infection by orthograde root filling. The treatment has a remarkably high degree of success. Nevertheless, endodontic treatment can fail. Most failures occur when treatment procedures, mostly of a technical nature, have not reached a satisfactory standard for the control and elimination of infection. Even when the highest standards and the most careful procedures are followed, failures still occur. This is because there are root canal regions that cannot be cleaned and obturated with existing equipments, materials, and techniques, and thus, infection can persist. In very rare cases, there are also factors located within the inflamed periapical tissue that can interfere with post-treatment healing of the lesion. The data on the biological causes of endodontic failures are recent and scattered in various journals. This communication is meant to provide a comprehensive overview of the etio-pathogenesis of apical periodontitis and the causes of failed endodontic treatments that can be visualized in radiographs as asymptomatic post-treatment periapical radiolucencies.

  17. Leak detection of KNI seals

    International Nuclear Information System (INIS)

    Baranyai, G.; Peter, A.; Windberg, P.

    1990-03-01

    In Unit 3 and 4 of the Paks Nuclear Power Plant, Hungary, KNI type seals are used as lead-throughs with conical nickel sealing rings. Their failure can be critical for the operation of the reactor. An Acoustical Leak Detection System (ALDS) was constructed and tested for the operational testing of the seals. Some individual papers are presented in this collection on the calibration and testing of the ALDS intended to be placed on the top of the reactor vessels. The papers include simulation measurements of Unit 3 of NPP, laboratory experiments, evaluation of measurements, and further development needs with the ALDS. (R.P.) 50 figs.; 19 tabs

  18. Unification of reactor elastomeric sealing based on material

    International Nuclear Information System (INIS)

    Sinha, N.K.; Raj, Baldev

    2012-01-01

    The unification of elastomeric sealing applications of Indian nuclear reactors based on a few qualified fluoroelastomer/perfluoroelastomer compounds and standardized approaches for finite element analysis (FEA) based design, manufacturing process and antifriction coatings is discussed. It is shown that the advance polymer architecture based Viton ® formulation developed for inflatable seals of 500 MWe Prototype Fast Breeder Reactor (PFBR) and its four basic variations can encompass other sealing applications of PFBR with minimum additional efforts on development and validation. Changing the blend ratio of Viton ® GBL 200S and 600S in inflatable seal formulation could extend its use to Pressurized Heavy Water Reactors (PHWRs). The higher operating temperature of Advanced Heavy Water Reactor (AHWR) seals expands the choice to perfluoroelastomers. FEA based on plane-strain/axisymmetric modeling (with Mooney–Rivlin as the basic constitutive model), seal manufacture by cold feed extrusion and injection molding as well as plasma Teflon-like coating belonging to two variations obtained from the development of inflatable seals provide the necessary standardization for unification. The gains in simplification of design, development and operation of seals along with the enhancements of safety and reliability are expected to be substantial.

  19. Adenovirus entry from the apical surface of polarized epithelia is facilitated by the host innate immune response.

    Directory of Open Access Journals (Sweden)

    Poornima L N Kotha

    2015-03-01

    Full Text Available Prevention of viral-induced respiratory disease begins with an understanding of the factors that increase or decrease susceptibility to viral infection. The primary receptor for most adenoviruses is the coxsackievirus and adenovirus receptor (CAR, a cell-cell adhesion protein normally localized at the basolateral surface of polarized epithelia and involved in neutrophil transepithelial migration. Recently, an alternate isoform of CAR, CAREx8, has been identified at the apical surface of polarized airway epithelia and is implicated in viral infection from the apical surface. We hypothesized that the endogenous role of CAREx8 may be to facilitate host innate immunity. We show that IL-8, a proinflammatory cytokine and a neutrophil chemoattractant, stimulates the protein expression and apical localization of CAREx8 via activation of AKT/S6K and inhibition of GSK3β. Apical CAREx8 tethers infiltrating neutrophils at the apical surface of a polarized epithelium. Moreover, neutrophils present on the apical-epithelial surface enhance adenovirus entry into the epithelium. These findings suggest that adenovirus evolved to co-opt an innate immune response pathway that stimulates the expression of its primary receptor, apical CAREx8, to allow the initial infection the intact epithelium. In addition, CAREx8 is a new target for the development of novel therapeutics for both respiratory inflammatory disease and adenoviral infection.

  20. Water-soluble vitamin homeostasis in fasting northern elephant seals (Mirounga angustirostris) measured by metabolomics analysis and standard methods

    Science.gov (United States)

    Boaz, Segal M.; Champagne, Cory D.; Fowler, Melinda A.; Houser, Dorian H.; Crocker, Daniel E.

    2011-01-01

    Despite the importance of water-soluble vitamins to metabolism, there is limited knowledge of their serum availability in fasting wildlife. We evaluated changes in water-soluble vitamins in northern elephant seals, a species with an exceptional ability to withstand nutrient deprivation. We used a metabolomics approach to measure vitamins and associated metabolites under extended natural fasts for up to seven weeks in free-ranging lactating or developing seals. Water-soluble vitamins were not detected with this metabolomics platform, but could be measured with standard assays. Concentrations of measured vitamins varied independently, but all were maintained at detectable levels over extended fasts, suggesting that defense of vitamin levels is a component of fasting adaptation in the seals. Metabolomics was not ideal for generating complete vitamin profiles in this species, but gave novel insights into vitamin metabolism by detecting key related metabolites. For example, niacin level reductions in lactating females were associated with significant reductions in precursors suggesting downregulation of the niacin synthetic pathway. The ability to detect individual vitamins using metabolomics may be impacted by the large number of novel compounds detected. Modifications to the analysis platforms and compound detection algorithms used in this study may be required for improving water-soluble vitamin detection in this and other novel wildlife systems. PMID:21983145

  1. Proliferative effects of apical, but not basal, matrix metalloproteinase-7 activity in polarized MDCK cells

    International Nuclear Information System (INIS)

    Harrell, Permila C.; McCawley, Lisa J.; Fingleton, Barbara; McIntyre, J. Oliver; Matrisian, Lynn M.

    2005-01-01

    Matrix metalloproteinase-7 (MMP-7) is primarily expressed in glandular epithelium. Therefore, its mechanism of action may be influenced by its regulated vectorial release to either the apical and/or basolateral compartments, where it would act on its various substrates. To gain a better understanding of where MMP-7 is released in polarized epithelium, we have analyzed its pattern of secretion in polarized MDCK cells expressing stably transfected human MMP-7 (MDCK-MMP-7), and HCA-7 and Caco2 human colon cancer cell lines. In all cell lines, latent MMP-7 was secreted to both cellular compartments, but was 1.5- to 3-fold more abundant in the basolateral compartment as compared to the apical. However, studies in the MDCK system demonstrated that MMP-7 activity was 2-fold greater in the apical compartment of MDCK-MMP-7 HIGH -polarized monolayers, which suggests the apical co-release of an MMP-7 activator. In functional assays, MMP-7 over-expression increased cell saturation density as a result of increased cell proliferation with no effect on apoptosis. Apical MMP-7 activity was shown to be responsible for the proliferative effect, which occurred, as demonstrated by media transfer experiments, through cleavage of an apical substrate and not through the generation of a soluble factor. Taken together, our findings demonstrate the importance of MMP-7 secretion in relation to its mechanism of action when expressed in a polarized epithelium

  2. Machine Vision Inspection of Polymeric Traypack Seal Areas

    National Research Council Canada - National Science Library

    Coburn, John

    2002-01-01

    .... Since entrapped matter can lead to open seals, defects, and seal anomalies, a method of measurement for seal area contamination is useful in quantifying effects of filler changes, line speeds, and product formulations...

  3. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

    Directory of Open Access Journals (Sweden)

    Taha Özyürek

    2017-11-01

    Full Text Available Objectives To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR, Mtwo-R, ProTaper Next (PTN, and Twisted File Adaptive (TFA systems. Materials and Methods The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU, Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ2 tests using SPSS 21.0 software. Results New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  4. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments.

    Science.gov (United States)

    Özyürek, Taha; Tek, Vildan; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ 2 tests using SPSS 21.0 software. New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  5. Role of apical oxygen in 2-1-4 electron-doped superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Richard, P.; Riou, G.; Jandl, S.; Poirier, M.; Fournier, P.; Nekvasil, V.; Divis, M

    2004-08-01

    We report a crystal-field infrared transmission and Raman study of oxygenated and reduced Nd{sub 2-x}Ce{sub x}CuO{sub 4} single crystals. Some Nd{sup 3+} crystal-field absorption bands corresponding to rare-earth ions in non-regular sites are attributed to Nd{sup 3+} ions in the vicinity of apical oxygens. This is correlated with a study of the A{sup *} ({approx}580 cm{sup -1}) Raman local mode and with the transport properties of undoped materials. We show that the apical oxygen is not removed by the reduction.

  6. Apical sorting of lysoGPI-anchored proteins occurs independent of association with detergent-resistant membranes but dependent on their N-glycosylation.

    Science.gov (United States)

    Castillon, Guillaume Alain; Michon, Laetitia; Watanabe, Reika

    2013-06-01

    Most glycosylphosphatidylinositol-anchored proteins (GPI-APs) are located at the apical surface of epithelial cells. The apical delivery of GPI-APs is believed to result from their association with lipid rafts. We find that overexpression of C-terminally tagged PGAP3 caused predominant production of lysoGPI-APs, an intermediate precursor in the GPI lipid remodeling process in Madin-Darby canine kidney cells. In these cells, produced lysoGPI-APs are not incorporated into detergent-resistant membranes (DRMs) but still are delivered apically, suggesting that GPI-AP association with DRMs is not necessary for apical targeting. In contrast, apical transport of both fully remodeled and lyso forms of GPI-APs is dependent on N-glycosylation, confirming a general role of N-glycans in apical protein transport. We also find that depletion of cholesterol causes apical-to-basolateral retargeting not only of fully remodeled GPI-APs, but also of lysoGPI-APs, as well as endogenous soluble and transmembrane proteins that would normally be targeted to the apical membrane. These findings confirm the essential role for cholesterol in the apical protein targeting and further demonstrate that the mechanism of cholesterol-dependent apical sorting is not related to DRM association of GPI-APs.

  7. Reactor coolant pump shaft seal behavior during station blackout

    International Nuclear Information System (INIS)

    Kittmer, C.A.; Wensel, R.G.; Rhodes, D.B.; Metcalfe, R.; Cotnam, B.M.; Gentili, H.; Mings, W.J.

    1985-04-01

    A testing program designed to provide fundamental information pertaining to the behavior of reactor coolant pump (RCP) shaft seals during a postulated nuclear power plant station blackout has been completed. One seal assembly, utilizing both hydrodynamic and hydrostatic types of seals, was modeled and tested. Extrusion tests were conducted to determine if seal materials could withstand predicted temperatures and pressures. A taper-face seal model was tested for seal stability under conditions when leaking water flashes to steam across the seal face. Test information was then used as the basis for a station blackout analysis. Test results indicate a potential problem with an elastomer material used for O-rings by a pump vendor; that vendor is considering a change in material specification. Test results also indicate a need for further research on the generic issue of RCP seal integrity and its possible consideration for designation as an unresolved safety issue

  8. Prevalence and activity of Epstein-Barr virus and human cytomegalovirus in symptomatic and asymptomatic apical periodontitis lesions.

    Science.gov (United States)

    Hernádi, Katinka; Szalmás, Anita; Mogyorósi, Richárd; Czompa, Levente; Veress, György; Csoma, Eszter; Márton, Ildikó; Kónya, József

    2010-09-01

    Apical periodontitis is a polymicrobial inflammation with a dominant flora of opportunistic Gram-negative bacteria; however, a pathogenic role of human herpesviruses such as Epstein-Barr virus (EBV) and human cytomegalovirus (HCMV) has been implicated recently. The aims of this study were to determine the prevalence, activity, and disease association of EBV and HCMV in apical periodontitis in an Eastern Hungarian population. Forty samples with apical periodontitis (17 symptomatic and 23 asymptomatic) and 40 healthy pulp controls were collected. EBV and HCMV prevalences were measured by polymerase chain reaction (PCR) detection of the viral DNA and viral activity was tested by reverse-transcription PCR amplification of viral messenger RNA. EBV DNA and EBNA-2 messenger RNA were found in apical periodontitis lesions at significantly (p apical lesions (10%) and controls (0%). The presence of EBV DNA in apical lesions was associated significantly with large (> or = 5 mm) lesion size (p = 0.02) but not with symptoms (p = 0.30). Symptomatic manifestation was significantly associated with the co-occurrence (odds ratio [OR], 8.80; 95% confidence interval [CI], 1.69-45.76) but not the sole occurrences of EBNA-2 messenger RNA (OR, 2.29; 95% CI, 0.48-11.06) and large lesion size (OR, 4.02; 95% CI, 0.81-19.89). EBV infection is a frequent event in apical periodontitis, whereas the involvement of HCMV still remains to be elucidated. This study showed that symptomatic manifestation was likely to occur if a large-sized apical periodontitis lesion is aggravated with active EBV infection. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. A Comparison of Apical Transportation in Severely Curved Canals Induced by Reciproc and BioRaCe Systems.

    Science.gov (United States)

    Nabavizadeh, Mohammadreza; Abbaszadegan, Abbas; Khojastepour, Leila; Amirhosseini, Mohsen; Kiani, Ebrahim

    2014-01-01

    Preserving the apical root structure during cleaning and shaping of the canal has always been a challenge in endodontics particularly when the root canals are curved. The purpose of this in vitro study was to compare the apical transportation induced by the Reciproc and BioRaCe rotary systems in preparing the mesiobuccal root canal of the human maxillary molars. The mesiobuccal canals of sixty extracted maxillary molars with curvature angle of 25˚-35˚ were selected and randomly assigned into two groups. Each canal was prepared by either Reciproc or BioRaCe rotary systems. A double-digital radiographic technique and AutoCAD software were used to compare the apical transportation at 0.5, 1, 2, 3, 4 and 5 mm distances from the working length (WL). The distance between the master apical rotary file and the initial K-file in the superimposed radiographs determined the amount of apical transportation. An independent t-test was used to compare the groups. The statistical significant level was set at 0.05. Apical transportation of the Reciproc group was significantly greater than the BioRaCe group in all distances (P<0.001). The maximum apical transportation occurred in the Reciproc group at 0.5 mm from the WL (0.048±0.0028 mm) and the minimum occurred for BioRaCe at 5 mm from the WL (0.010±0.0005 mm). The Reciproc system produced significantly more apical transportation than the BioRaCe, but this fact does not seem to negatively alter the clinical success or quality of root canal treatment.

  10. Cask systems development program seal technology

    International Nuclear Information System (INIS)

    Madsen, M.M.; Humphreys, D.L.; Edwards, K.R.

    1991-01-01

    General design or test performance requirements for radioactive materials (RAM) packages are specified in Title 10 of the US Code of Federal Regulations Part 71 (10 CFR 71). Seals that provide the containment system interface between the packaging body and the closure must function in both high- and low-temperature environments under dynamic and static conditions. Experiments were performed to characterize the performance of several seal materials at low temperatures. Helium leak tests on face seals were used to compare the materials. Materials tested include butyl, neoprene, ethylene propylene, fluorosilicone, silicone, Eypel, Kalrez, Teflon, fluorocarbon, and Teflon/silicone composites. Results show that the seal materials tested, with the exception of silicone S613-60, are not leak tight (1 x 10 -7 std cm 3 /s) at manufacturer low-temperature ratings

  11. High pressure thimble/guide tube seal fitting with built-in low pressure seal especially suitable for facilitated and more efficient nuclear reactor refueling service

    International Nuclear Information System (INIS)

    Bhatt, P.N.; Blaushield, R.M.

    1991-01-01

    This patent describes a HP/LP seal arrangement for an elongated guide tube and an elongated thimble disposed therein. The guide tube and thimble extending outwardly from the core of a nuclear reactor to a seal table where the guide tube is welded to the seal table to provide a high pressure seal relative thereto. It comprises: a tubular seal fitting disposed in alignment with the guide tube with the thimble extending therethrough on the low pressure side of the seal table; first high pressure sealing means coupling one end of the fitting to an end of the guide tube to prevent leakage from within the guide tube; inwardly facing thread means disposed adjacent the other and outer end of the seal fitting; a nut having an opening through which the thimble extends and further having outwardly facing threading in mating engagement with the fitting thread means; the fitting having a seal seat spaced longitudinally inwardly from the thread means and facing the fitting outer end and further disposed annularly about the inner surface of the fitting; deformable ring seal means; second releasable high pressure sealing means coupling the thimble to the outer end portion of the guide tube

  12. Seal for an object containing nuclear fuel

    International Nuclear Information System (INIS)

    Scheuerpflug, W.; Nentwich, D.

    1977-01-01

    This seal which cannot be counterfeited, specially for sealing nuclear objects, e.g. fuel rods, not only makes any damage which has taken place obvious, but makes identification according to a key possible. For this purpose a minimum number of 'particles' or small bodies, which are identical but of different permeability, are fixed inside a short tube during 'loading' of the seal in a certain or an accidental sequence. The sequence of the spheres, which represents a key, can only be determined by special electromagnetic measuring equipment. On first opening the seal, this key sequence is irrevocably destroyed. (HP) [de

  13. Properties of Sealing Materials in Groundwater Wells

    DEFF Research Database (Denmark)

    Köser, Claus

    pellets as sealing material in groundwater wells. The way and the pattern, in which bentonite pellets are deposited, have been shown to have an effect on the swelling pressure of the bentonite seal. During the transport phase of pellets from the terrain to a given sedimentation depth, a sorting process......) into densities for clay/water systems has been developed. This method has successfully been used to evaluate e.g., macroporosity, homogenization of the bentonite seal during the hydration of water, hydraulic conductivity and the creation of channels in the bentonite seals. Based on the results obtained...

  14. Northern Elephant Seals Memorize the Rhythm and Timbre of Their Rivals' Voices.

    Science.gov (United States)

    Mathevon, Nicolas; Casey, Caroline; Reichmuth, Colleen; Charrier, Isabelle

    2017-08-07

    The evolutionary origin of rhythm perception, a cognitive ability essential to musicality, remains unresolved [1-5]. The ability to perceive and memorize rhythmic sounds is widely shared among humans [6] but seems rare among other mammals [7, 8]. Although the perception of temporal metrical patterns has been found in a few species, this ability has only been demonstrated through behavioral training [9] (but see [10] for an example of spontaneous tempo coordination in a bonobo), and there is no experimental evidence to indicate its biological function. Furthermore, there is no example of a non-human mammal able to remember and recognize auditory rhythmic patterns among a wide range of tempi. In the northern elephant seal Mirounga angustirostris, the calls of mature males comprise a rhythmic series of pulses, with the call of each individual characterized by its tempo and timbre; these individual vocal signatures are stable over years and across contexts [11]. Here, we report that northern elephant seal males routinely memorize and recognize the unique tempo and timbre of their rivals' voices and use this rhythmic information to individually identify competitors, which facilitates navigation within the social network of the rookery. By performing playbacks with natural and modified vocalizations, we show that males are sensitive to call rhythm disruption independently of modification of spectral features and that they use both temporal and spectral cues to identify familiar rivals. While spectral features of calls typically encode individual identity in mammalian vocalizations [12], this is the first example of this phenomenon involving sound rhythm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths

    NARCIS (Netherlands)

    Liu, R.; Kaiwar, A.; Shemesh, H.; Wesselink, P.R.; Hou, B.; Wu, M.K.

    2013-01-01

    Introduction The aim of this study was to compare the incidence of apical root cracks and dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Methods Two hundred forty mandibular incisors were mounted in resin blocks with simulated

  16. Responses of Metabolites in Soybean Shoot Apices to Changing Atmospheric Carbon Dioxide Concentrations

    Directory of Open Access Journals (Sweden)

    Richard Sicher

    2012-01-01

    Full Text Available Soybean seedlings were grown in controlled environment chambers with CO2 partial pressures of 38 (ambient and 72 (elevated Pa. Five or six shoot apices were harvested from individual 21- to 24-day-old plants. Metabolites were analyzed by gas chromatography and, out of 21 compounds, only sucrose and fructose increased in response to CO2 enrichment. One unidentified metabolite, Unk-21.03 decreased up to 80% in soybean apices in response to elevated CO2. Levels of Unk-21.03 decreased progressively when atmospheric CO2 partial pressures were increased from 26 to 100 Pa. Reciprocal transfer experiments showed that Unk-21.03, and sucrose in soybean apices were altered slowly over several days to changes in atmospheric CO2 partial pressures. The mass spectrum of Unk-21.03 indicated that this compound likely contained both an amino and carboxyl group and was structurally related to serine and aspartate. Our findings suggested that CO2 enrichment altered a small number of specific metabolites in soybean apices. This could be an important step in understanding how plant growth and development are affected by carbon dioxide enrichment.

  17. Cone beam computed tomography study of apical root resorption induced by Herbst appliance

    Science.gov (United States)

    SCHWARTZ, João Paulo; RAVELI, Taísa Boamorte; ALMEIDA, Kélei Cristina de Mathias; SCHWARTZ-FILHO, Humberto Osvaldo; RAVELI, Dirceu Barnabé

    2015-01-01

    Objective This study evaluated the frequency of root resorption during the orthodontic treatment with Herbst appliance by Cone Beam Computed Tomography (CBCT). Material and Methods The sample comprised 23 patients (11 men, 12 women; mean ages 15.76±1.75 years) with Class II division 1 malocclusion, treated with Herbst appliance. CBCT was obtained before treatment (T0) and after Herbst treatment (T1). All the dental roots, except third molars, were evaluated, and apical root resorption was determined using the axial guided navigation method. Paired t-tests and Wilcoxon T Test were used to compare the dependent samples in parametric and nonparametric cases, respectively. Chi-Square Test with Yates’ correction was used to evaluate the relationship between apical root resorption and gender. Results were considered at a significance level of 5%. Results Apical resorption was detected by CBCT in 57.96% of 980 roots that underwent Herbst appliance treatment. All patients had minimal resorption and there was no statistical significance between the genders. Conclusion CBCT three-dimensional evaluation showed association between Herbst appliance and minimal apical root resorption, mostly in the anchoring teeth, without clinical significance. PMID:26537718

  18. Cone beam computed tomography study of apical root resorption induced by Herbst appliance

    Directory of Open Access Journals (Sweden)

    João Paulo SCHWARTZ

    2015-10-01

    Full Text Available Objective This study evaluated the frequency of root resorption during the orthodontic treatment with Herbst appliance by Cone Beam Computed Tomography (CBCT.Material and Methods The sample comprised 23 patients (11 men, 12 women; mean ages 15.76±1.75 years with Class II division 1 malocclusion, treated with Herbst appliance. CBCT was obtained before treatment (T0 and after Herbst treatment (T1. All the dental roots, except third molars, were evaluated, and apical root resorption was determined using the axial guided navigation method. Paired t-tests and Wilcoxon T Test were used to compare the dependent samples in parametric and nonparametric cases, respectively. Chi-Square Test with Yates’ correction was used to evaluate the relationship between apical root resorption and gender. Results were considered at a significance level of 5%.Results Apical resorption was detected by CBCT in 57.96% of 980 roots that underwent Herbst appliance treatment. All patients had minimal resorption and there was no statistical significance between the genders.Conclusion CBCT three-dimensional evaluation showed association between Herbst appliance and minimal apical root resorption, mostly in the anchoring teeth, without clinical significance.

  19. Replacement of nickel sealing rings by expanded graphite sealing rings -upgrading of SG primary collector flange connection

    Energy Technology Data Exchange (ETDEWEB)

    Cikryt, F.; Bednarek, L.; Kusyn, L. [Vitkovice, Ostrava (Switzerland)

    1997-12-31

    One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation experience proved relatively low service of bolts, damage of thread holes and sealing grooves. As the degree of mechanical load is one of the vital parameters influencing the damage of sealing set, in 1996 we started with the works aimed at a possibility of nickel sealing rings replacement for a more modern type of sealing which assure the higher reliability and service life of the individual part of sealing set under the reduced load.

  20. Replacement of nickel sealing rings by expanded graphite sealing rings -upgrading of SG primary collector flange connection

    Energy Technology Data Exchange (ETDEWEB)

    Cikryt, F; Bednarek, L; Kusyn, L [Vitkovice, Ostrava (Switzerland)

    1998-12-31

    One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation experience proved relatively low service of bolts, damage of thread holes and sealing grooves. As the degree of mechanical load is one of the vital parameters influencing the damage of sealing set, in 1996 we started with the works aimed at a possibility of nickel sealing rings replacement for a more modern type of sealing which assure the higher reliability and service life of the individual part of sealing set under the reduced load.

  1. Application of radioisotope technique for investigation of pumps seals

    International Nuclear Information System (INIS)

    Antoszewski, B.; Zorawska, A.

    1988-01-01

    Radioisotope method of measuring the wear of rings of the face mechanical seals, bush in soft seals, and leakage in double mechanical seals is described. The examples are given. It is found that radioisotope technique can be used for investigation of the seals. (author)

  2. Legacy HMSRP Hawaiian Monk Seals Observers

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set documents observers that have collected monk seal data as part of the ongoing monk seal population assessment efforts by PSD personnel and cooperating...

  3. HMSRP Hawaiian Monk Seal Entanglement data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data set contains records of all entanglements of Hawaiian monk seals in marine debris. The data set comprises records of seals entangled by derelict fishing...

  4. Salt brickwork as long-term sealing in salt formations

    International Nuclear Information System (INIS)

    Walter, F.; Yaramanci, U.

    1993-01-01

    Radioactive wastes can be disposed of in deep salt formations. Rock salt is a suitable geologic medium because of its unique characteristics. Open boreholes, shafts and drifts are created to provide physical access to the repository. Long-term seals must be emplaced in these potential pathways to prevent radioactive release into the biosphere. The sealing materials must be mechanically and, most important, geochemically stable within the host rock. Salt bricks made from compressed salt-powder are understood to be the first choice long-term sealing material. Seals built of salt bricks will be ductile. Large sealing systems are built by combining the individual bricks with mortar. Raw materials for mortar are fine-grained halite powder and ground saliferous clay. This provides for the good adhesive strength of the mortar to the bricks and the high shear-strength of the mortar itself. To test the interaction of rock salt with an emplaced long-term seal, experiments will be carried out in situ, in the Asse salt mine in Germany. Simple borehole sealing experiments will be performed in horizontal holes and a complicated drift sealing experiment is planned, to demonstrate the technology of sealing a standard size drift or shaft inside a disturbed rock mass. Especially, the mechanical stability of the sealing system has to be demonstrated

  5. Sealed source peer review plan

    International Nuclear Information System (INIS)

    Feldman, Alexander; Leonard, Lee; Burns, Ron

    2009-01-01

    Sealed sources are known quantities of radioactive materials that have been encapsulated in quantities that produce known radiation fields. Sealed sources have multiple uses ranging from instrument calibration sources to sources that produce radiation fields for experimental applications. The Off-Site Source Recovery (OSR) Project at Los Alamos National Laboratory (LANL), created in 1999, under the direction of the Waste Management Division of the U.S. Department of Energy (DOE) Albuquerque has been assigned the responsibility to recover and manage excess and unwanted radioactive sealed sources from the public and private sector. LANL intends to ship drums containing qualified sealed sources to the Waste Isolation Pilot Plant (WIPP) for disposal. Prior to shipping, these drums must be characterized with respect to radiological content and other parameters. The U. S. Environmental Protection Agency (EPA) requires that ten radionulcides be quantified and reported for every container of waste to be disposed in the WIPP. The methods traditionally approved by the EPA include non-destructive assay (NDA) in accordance with Appendix A of the Contact-Handled Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (DOE, 2002) (CH WAC). However, because of the nature and pedigree of historical records for sealed sources and the technical infeasibility of performing NDA on these sources, LANL proposes to characterize the content of these waste drums using qualified existing radiological data in lieu of direct measurement. This plan describes the process and documentation requirements for the use of the peer review process to qualify existing data for sealed radiological sources in lieu of perfonning radioassay. The peer review process will be performed in accordance with criteria provided in 40 CFR (section) 194.22 which specifies the use of the NUREG 1297 guidelines. The plan defines the management approach, resources, schedule, and technical requirements

  6. Molybdenum sealing glass-ceramic composition

    International Nuclear Information System (INIS)

    Eagan, R.J.

    1976-01-01

    A glass-ceramic composition is described having low hydrogen and helium permeability properties, along with high fracture strength, and a thermal coefficient of expansion similar to that of molybdenum. The composition is adaptable for hermetically sealing to molybdenum at temperatures between 900 and about 950 0 C to form a hermetically sealed insulator body

  7. Cytoplasmic Dynein Regulation by Subunit Heterogeneity and Its Role in Apical Transport

    Science.gov (United States)

    Tai, Andrew W.; Chuang, Jen-Zen; Sung, Ching-Hwa

    2001-01-01

    Despite the existence of multiple subunit isoforms for the microtubule motor cytoplasmic dynein, it has not yet been directly shown that dynein complexes with different compositions exhibit different properties. The 14-kD dynein light chain Tctex-1, but not its homologue RP3, binds directly to rhodopsin's cytoplasmic COOH-terminal tail, which encodes an apical targeting determinant in polarized epithelial Madin-Darby canine kidney (MDCK) cells. We demonstrate that Tctex-1 and RP3 compete for binding to dynein intermediate chain and that overexpressed RP3 displaces endogenous Tctex-1 from dynein complexes in MDCK cells. Furthermore, replacement of Tctex-1 by RP3 selectively disrupts the translocation of rhodopsin to the MDCK apical surface. These results directly show that cytoplasmic dynein function can be regulated by its subunit composition and that cytoplasmic dynein is essential for at least one mode of apical transport in polarized epithelia. PMID:11425878

  8. Comparison of apical debris extrusion using a conventional and two rotary techniques.

    Science.gov (United States)

    Adl, Alireza; Sahebi, Safoora; Moazami, Fariborz; Niknam, Mahnaz

    2009-01-01

    Preparation techniques and instruments produce and push debris out of canals. This can induce inflammation within the periapical area. Therefore, instrumentation that causes less extrusion of debris is more desirable. The purpose of this in vitro study was to evaluate the quantity of debris extruded from the apical foramen during root canal preparation by using one hand, and two rotary instrumentation techniques. Three different groups each with 12 mesiobuccal roots of human maxillary first molar were instrumented using either step-back technique with hand instruments, FlexMaster or Mtwo rotary system. Debris extruded from the apical foramen during canal preparation was collected. The mean dry weights of debris were compared using one-way ANOVA. Step-back group had a significantly greater mean weight of debris compared to the other two groups (Pengine driven techniques were associated with less apical debris extrusion. [Iranian Endodontic Journal 2009;4(4):135-8].

  9. Pillow seal system at the BigRIPS separator

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, K., E-mail: ktanaka@riken.jp; Inabe, N.; Yoshida, K.; Kusaka, K.; Kubo, T.

    2013-12-15

    Highlights: • Pillow seal system has been installed for a high-intensity RI-beam facility at RIKEN. • It is aimed at facilitating remote maintenance under high residual radiation. • Local radiation shields are integrated with one of the pillow seals. • Pillow seals have been aligned to the beam axis within 1mm accuracy. • A leakage rate of 10{sup –9} Pa m{sup 3}/s has been achieved with our pillow seal system. -- Abstract: We have designed and installed a pillow seal system for the BigRIPS fragment separator at the RIKEN Radioactive Isotope Beam Factory (RIBF) to facilitate remote maintenance in a radioactive environment. The pillow seal system is a device to connect a vacuum chamber and a beam tube. It allows quick attachment and detachment of vacuum connections in the BigRIPS separator and consists of a double diaphragm with a differential pumping system. The leakage rate achieved with this system is as low as 10{sup –9} Pa m{sup 3}/s. We have also designed and installed a local radiation-shielding system, integrated with the pillow seal system, to protect the superconducting magnets and to reduce the heat load on the cryogenic system. We present an overview of the pillow seal and the local shielding systems.

  10. Plastic profiled sealing element for household refrigeration appliances

    Energy Technology Data Exchange (ETDEWEB)

    Wunderlich, E; Robl, G

    1988-12-28

    A plastic profiled sealing element for household refrigeration appliances, such as freezers, refrigerators, and freezer compartments, includes a sealing bellows having a hose-shaped cross section. The sealing bellows is provided with two side walls and a covering wall, and is made of a plastic that has been set by means of a softener so as to be continuously flexible. Further, the profiled sealing element is provided with an anchor member made of a plastic of the same or different material hardness, with the sealing bellows and the anchor member being connected with one another to form a unit. The cross sections of the two side walls of the sealing bellows narrow as the side walls rise from the region of the connection of the side walls with the covering wall of the anchor member to approximately half the height of the sealing bellows, so that the side walls become increasingly thinner. Thereafter, the cross sections of the side walls increase again to the edges of the covering wall of the sealing bellows, until the side walls again reach approximately their initial cross sections. The side walls, on the one hand, and the covering wall, on the other hand, are kept flexible by means of softeners having different characteristics.

  11. Influence of cervical preflaring on apical file size determination.

    Science.gov (United States)

    Pecora, J D; Capelli, A; Guerisoli, D M Z; Spanó, J C E; Estrela, C

    2005-07-01

    To investigate the influence of cervical preflaring with different instruments (Gates-Glidden drills, Quantec Flare series instruments and LA Axxess burs) on the first file that binds at working length (WL) in maxillary central incisors. Forty human maxillary central incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL was set 1 mm short of the apical foramen. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle thirds of the root canal. Group 2 had the cervical and middle portion of the root canals enlarged with Gates-Glidden drills sizes 90, 110 and 130. Group 3 had the cervical and middle thirds of the root canals enlarged with nickel-titanium Quantec Flare series instruments. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle portions of root canals from group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were evaluated for each sample. Significant differences were found between experimental groups regarding anatomical diameter at the WL and the first file to bind in the canal (P Flare instruments were ranked in an intermediary position, with no statistically significant differences between them (0.093 mm average). The instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the

  12. Dynamics of face seals for high speed turbomachinery

    Science.gov (United States)

    Leefe, Simon

    1993-10-01

    Face seals in rocket engine fuel and oxidizer turbopumps have been the subject of intense investigation for over 25 years. While advances have been made in the understanding of thin film lubrication between seal faces, valuable data has been produced on the friction and wear of material pairs in cryogenic environments; pioneering work has been done on the effect of lubricant phase change in seals, and many improvements have been made in mechanical seal design. Relatively superficial attention has been given to the vibrational dynamics of face seals in high-speed turbomachinery. BHR Group Ltd. (formerly BHRA) has recently completed the first stage of a study, commissioned by the European Space Agency, to investigate this area. This has involved the development of a two-dimensional adiabatic, turbulent lubrication model for thick gas film applications, the production of an integrated mathematical model of gas seal vibrational dynamics for thin film applications, implementation in software, the undertaking of an experimental program to validate software against variations in operating conditions and design variables, and suggestions for improved seal design.

  13. mRNA expression of genes regulating lipid metabolism in ringed seals (Pusa hispida) from differently polluted areas

    International Nuclear Information System (INIS)

    Castelli, Martina Galatea; Rusten, Marte; Goksøyr, Anders; Routti, Heli

    2014-01-01

    Highlights: •Genes regulating lipid metabolism were studied in ringed seals. •We compared highly contaminated Baltic seals and less contaminated Svalbard seals. •mRNA expression of hepatic PPARγ was higher in the Baltic seals. •mRNA expression of adipose PPARγ target genes was higher in the Baltic seals. •Contaminant exposure may affect lipid metabolism in the Baltic ringed seals. -- Abstract: There is a growing concern about the ability of persistent organic pollutants (POPs) to influence lipid metabolism. Although POPs are found at high concentrations in some populations of marine mammals, for example in the ringed seal (Pusa hispida) from the Baltic Sea, little is known about the effects of POPs on their lipid metabolism. An optimal regulation of lipid metabolism is crucial for ringed seals during the fasting/molting season. This is a physiologically stressful period, during which they rely on the energy stored in their fat reserves. The mRNA expression levels for seven genes involved in lipid metabolism were analyzed in liver and/or blubber tissue from molting ringed seals from the polluted Baltic Sea and a less polluted reference location, Svalbard (Norway). mRNA expression of genes encoding peroxisome proliferator-activated receptors (PPAR) α and γ and their target genes acyl-coenzyme A oxidase 1 (ACOX1) and cluster of differentiation 36 (CD36) were analyzed in liver. mRNA expression level of genes encoding PPARβ, PPARγ and their target genes encoding fatty acid binding protein 4 (FABP4) and adiponectin (ADIPOQ) were measured in inner and middle blubber layers. In addition, we evaluated the influence of molting status on hepatic mRNA expression of genes encoding PPARs and their target genes in ringed seals from Svalbard. Our results show higher mRNA expression of genes encoding hepatic PPARγ and adipose PPARβ, FABP4, and ADIPOQ in the Baltic seals compared to the Svalbard seals. A positive relationship between mRNA expressions of genes

  14. mRNA expression of genes regulating lipid metabolism in ringed seals (Pusa hispida) from differently polluted areas

    Energy Technology Data Exchange (ETDEWEB)

    Castelli, Martina Galatea [Norwegian Polar Institute, Fram Centre, 9296 Tromsø (Norway); University of Bergen, Department of Biology, 5020 Bergen (Norway); Rusten, Marte; Goksøyr, Anders [University of Bergen, Department of Biology, 5020 Bergen (Norway); Routti, Heli, E-mail: heli.routti@npolar.no [Norwegian Polar Institute, Fram Centre, 9296 Tromsø (Norway)

    2014-01-15

    Highlights: •Genes regulating lipid metabolism were studied in ringed seals. •We compared highly contaminated Baltic seals and less contaminated Svalbard seals. •mRNA expression of hepatic PPARγ was higher in the Baltic seals. •mRNA expression of adipose PPARγ target genes was higher in the Baltic seals. •Contaminant exposure may affect lipid metabolism in the Baltic ringed seals. -- Abstract: There is a growing concern about the ability of persistent organic pollutants (POPs) to influence lipid metabolism. Although POPs are found at high concentrations in some populations of marine mammals, for example in the ringed seal (Pusa hispida) from the Baltic Sea, little is known about the effects of POPs on their lipid metabolism. An optimal regulation of lipid metabolism is crucial for ringed seals during the fasting/molting season. This is a physiologically stressful period, during which they rely on the energy stored in their fat reserves. The mRNA expression levels for seven genes involved in lipid metabolism were analyzed in liver and/or blubber tissue from molting ringed seals from the polluted Baltic Sea and a less polluted reference location, Svalbard (Norway). mRNA expression of genes encoding peroxisome proliferator-activated receptors (PPAR) α and γ and their target genes acyl-coenzyme A oxidase 1 (ACOX1) and cluster of differentiation 36 (CD36) were analyzed in liver. mRNA expression level of genes encoding PPARβ, PPARγ and their target genes encoding fatty acid binding protein 4 (FABP4) and adiponectin (ADIPOQ) were measured in inner and middle blubber layers. In addition, we evaluated the influence of molting status on hepatic mRNA expression of genes encoding PPARs and their target genes in ringed seals from Svalbard. Our results show higher mRNA expression of genes encoding hepatic PPARγ and adipose PPARβ, FABP4, and ADIPOQ in the Baltic seals compared to the Svalbard seals. A positive relationship between mRNA expressions of genes

  15. HMSRP Hawaiian Monk Seal Handling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records for all handling and measurement of Hawaiian monk seals since 1981. Live seals are handled and measured during a variety of events...

  16. An Innovative Regenerative Endodontic Procedure Using Leukocyte and Platelet-rich Fibrin Associated with Apical Surgery: A Case Report.

    Science.gov (United States)

    Pinto, Nelson; Harnish, Alexandra; Cabrera, Carolina; Andrade, Catherine; Druttman, Tony; Brizuela, Claudia

    2017-11-01

    Regenerative endodontic procedures (REPs) associated with apical surgery could represent an alternative treatment strategy for patients whose teeth present incomplete root formation and extensive apical lesions. Leukocyte platelet-rich fibrin (L-PRF) has potential benefits in REPs; it could promote apical root formation and optimal bone healing. The aim of this case report was to describe innovative regenerative endodontic therapy using L-PRF in the root canal and an extensive apical lesion in an immature tooth with dens invaginatus and asymptomatic apical periodontitis. A healthy 20-year-old woman was referred to the dental clinic of the Universidad de Los Andes, Santiago, Chile, for endodontic treatment in tooth # 22 with incomplete root development and an extensive apical lesion. The diagnosis was asymptomatic apical periodontitis associated with dens invaginatus type II. The patient was treated with an innovative approach using L-PRF in REPs associated with apical surgery. Follow-ups were performed at 6 months and 1 year later. They included periapical radiographs, cone-beam computed tomographic imaging, sensitivity, and vitality tests. The clinical evaluations performed at 6 months and 1 year revealed an absence of symptoms. The radiographic evaluations showed that the apical lesion was resolved. The cone-beam images indicated that the root length increased and the walls had thickened. The sensitivity tests were positive, and the laser Doppler flowmetry showed positive blood flow after 1 year. The success of the results in this case report indicate that L-PRF can be used as a complement in apical surgery and REPs and could provide an innovative alternative treatment strategy for complex clinical cases like these. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. 39 CFR 2.4 - Seal.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Seal. 2.4 Section 2.4 Postal Service UNITED STATES... Secretary of State, and is required by 39 U.S.C. 207 to be judicially noticed. The Seal shall be in the... description of the Postal Service emblem is described at 39 CFR 221.7. ...

  18. Size and geometry of apical sesamoid fracture fragments as a determinant of prognosis in Thoroughbred racehorses.

    Science.gov (United States)

    Kamm, J L; Bramlage, L R; Schnabel, L V; Ruggles, A J; Embertson, R M; Hopper, S A

    2011-07-01

    Analysis was performed to examine a method for refining the preoperative prognosis for horses that had surgery to remove apical fractures of the proximal sesamoid bones (PSBs). To determine if: 1) there was a difference in size or configuration of apical fractures between the different anatomical locations of the PSBs, which have been shown to affect the prognosis; and 2) the size or configuration could predict the prognosis for racehorses with these fractures. The study included 110 weanlings and yearlings and 56 training racehorses that underwent surgery to remove apical PSB fractures. Radiographs of the fractures were used for measurement of the abaxial and axial proportion and the abaxial to axial ratio, and race records were used to determine average earnings per start (AEPS) and total post operative starts. Analysis of variance and regression statistics were used to compare the fragment sizes between the specific PSBs on each of the limbs and compare size and configuration of the fractures to prognosis. There was a significantly larger abaxial to axial ratio (more transverse fracture) for the forelimb medial sesamoids than for all other sesamoids in untrained racehorses (P = 0.03). There were no other significant differences in size. There was no relationship between fracture size or configuration and AEPS nor total post operative starts. Apical fractures in weanlings and yearlings tend to be more transverse in the forelimb medial PSBs than the other PSBs. Apical fracture size and geometry does not determine prognosis for apical sesamoid fractures. Horses that undergo surgery to remove larger apical fractures of the PSBs do not have a worse outcome than those horses with smaller fractures. © 2010 EVJ Ltd.

  19. Magnetic shaft seals prevent hazardous leakage from wastewater agitators

    International Nuclear Information System (INIS)

    Traino, F.A.

    1985-01-01

    The US Department of Energy's laboratory in Miamisburg, OH, operated by Monsanto Research Corporation, processes approximately 45,000 gallons per week of low-level radioactive wastewater to meet Federal Environmental Protection Agency quality standards. Preventing the spread of radioactive contamination throughout the operating area demands effective sealing of all process piping, valves, pumps, and agitators. Rotating shafts of pumps and agitators installed a the start of operations in 1947 were sealed by stuffing glands with graphite impregnated asbestos packing. These pumps proved to be unsatisfactory. In the mid-1970's, new process pumps with mechanical seals and some with magnetic drives were installed. Later, in January 1979, new agitator shaft drives with double tandem, spring-loaded mechanical seals were installed, maintenance of these pumps was costly. The agitator drive shafts were redesigned to accommodate magnetic seals of the type successfully used in blowers and vacuum/pressure pumps in other plant locations. One inherent advantage of the magnetic seal is that it operates with a face loading as much as 50% less than a conventional spring-loaded mechanical seal. The lower loading by a predetermined uniform magnetic force contributes to long face life. Other advantages include compactness, ease of assembly with only a few parts, and insensitivity to vibration. The magnetic shaft seals installed on the agitator shafts in February 1983 are still in service without any leakage or need for maintenance. Based on current operating data and a projected five-year meantime between failures, the estimated cost benefit of the magnetic seals over spring-loaded mechanical seals over spring-loaded mechanical seals will be $640 vs $2400 respectively per seal, with 60% less downtime for maintenance

  20. Performances of Magnetic Fluid Seal and Application to Turbopumps

    OpenAIRE

    北洞, 貴也; 黒川, 淳一; 宮副, 雄貴; 林, 正悦

    1994-01-01

    A magnetic fluid shaft seal can achieve zero-leakage and operate stably against shaft vibration, but the sealing pressure is very low. In order to improve the pressure performance of a magnetic fluid seal and apply it to a turbopump, the seal pressure characteristics are studied theoretically and experimentally. The Poisson equation for magnetic vector potential is solved by FEM, and the seal performances are determined by use of the Bernoulli equation. The validity of the theory is confirmed...