WorldWideScience

Sample records for aortic bifurcation self-expanding

  1. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  2. A new self-expandable aortic valved stent deployed above native leaflets for aortic insufficiency: an in vitro study.

    Science.gov (United States)

    Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y

    2012-12-01

    The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.

  3. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  4. Transcatheter aortic value implantation with self-expandable nitinol valved stent: an experimental study in sheep

    International Nuclear Information System (INIS)

    Jiang Haibin; Huang Xinmiao; Bai Yuan

    2011-01-01

    Objective: to determine the feasibility and safety of transcatheter aortic valve implantation with domestic self-expandable nitinol valved stent in experimental sheep. Methods: A fresh pig pericardium was cross-linked with a 0.6% glutaraldehyde solution for 36 hours and then sutured on a nitinol self-expandable stent. Ten healthy sheep of (46.00±2.60) kg body weight were chosen for the study. Under general anesthesia, the device was delivered through catheter into the native aortic valve of the sheep via the femoral artery or abdominal aorta. The animals were followed up for three months. Results: Six devices were successfully delivered at the desired position in six sheep with no occurrence of complications. Angiographic and hemodynamic studies confirmed that the stents were fixed at correct position with competent valve function immediately and 90 days after the procedure. Technical failure or fatal complications occurred in the remaining four sheep. Conclusion: Implantation of a domestic nitinol self-expandable stent at the aortic valve position through a transcatheter approach is feasible in experimental sheep. (authors)

  5. Transcatheter aortic-valve replacement with a self-expanding prosthesis.

    Science.gov (United States)

    Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K

    2014-05-08

    We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).

  6. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  7. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  8. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J

    2016-01-05

    Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of

  9. Supra-annular structure assessment for self-expanding transcatheter heart valve size selection in patients with bicuspid aortic valve.

    Science.gov (United States)

    Liu, Xianbao; He, Yuxin; Zhu, Qifeng; Gao, Feng; He, Wei; Yu, Lei; Zhou, Qijing; Kong, Minjian; Wang, Jian'an

    2018-04-01

    To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS. © 2018 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  10. Self-Expanding Transcatheter Aortic Valve System for Symptomatic High-Risk Patients With Severe Aortic Stenosis

    DEFF Research Database (Denmark)

    Reichenspurner, Hermann; Schaefer, Andreas; Schäfer, Ulrich

    2017-01-01

    BACKGROUND: The CENTERA transcatheter heart valve (THV) is a low-profile, self-expanding nitinol valve made from bovine pericardial tissue that is 14-F compatible with a motorized delivery system allowing for repositionability. OBJECTIVES: The pivotal study evaluated safety and efficacy of this THV...... permanent pacemaker was implanted in 4.5% of patients receiving the THV (4.9% for patients at risk). CONCLUSIONS: The herein described THV is safe and effective at 30 days with low mortality, significant improvements in hemodynamic outcomes, and low incidence of adverse events. Of particular interest...... is the low incidence of permanent pacemaker implantations. (Safety and Performance Study of the Edwards CENTERA-EU Self-Expanding Transcatheter Heart Valve [CENTERA-2]; NCT02458560)....

  11. Long term results of kissing stents in the aortic bifurcation

    NARCIS (Netherlands)

    Hinnen, J.W.; Konickx, M.A.; Meerwaldt, Robbert; Kolkert, J.L.P.; van der Palen, Jacobus Adrianus Maria; Huisman, A.B.

    2015-01-01

    BACKGROUND: To evaluate the long-term outcome after aortoiliac kissing stent placement and to analyze variables, which potentially influence the outcome of endovascular reconstruction of the aortic bifurcation. METHODS: All patients treated with aortoiliac kissing stents at our institution between

  12. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    Science.gov (United States)

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System.

    Science.gov (United States)

    van der Boon, Robert M A; Van Mieghem, Nicolas M; Theuns, Dominic A; Nuis, Rutger-Jan; Nauta, Sjoerd T; Serruys, Patrick W; Jordaens, Luc; van Domburg, Ron T; de Jaegere, Peter P T

    2013-09-30

    To determine pacemaker (PM) dependency at follow-up visit in patients who underwent new permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI). Single center prospective observational study including 167 patients without previous PM implantation who underwent TAVI with the self-expanding Medtronic CoreValve System (MCS) between November 2005 and February 2011. PM dependency was defined by the presence of a high degree atrioventricular block (HDAVB; second [AV2] and third degree [AV3B]), or a slow (atrial fibrilation with slow response (n=1, 2.8%) and left bundle branch block (n=1, 2.8%). Long term follow-up was complete for all patients and ranged from 1 to 40 months (median (IQR): 11.5 (5.0-18.0 months). Of those patients with a HDAVB, 16 out of the 30 patients (53.3%) were PM independent at follow-up visit (complete or partial resolution of the AV conduction abnormality). Overall, 20 out of the 36 patients (55.6%) who received a new PM following TAVI were PM independent at follow-up. Partial and even complete resolution of peri-operative AV conduction abnormalities after MCS valve implantation occurred in more than half of the patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis.

    Science.gov (United States)

    Grube, Eberhard; Laborde, Jean C; Zickmann, Bernfried; Gerckens, Ulrich; Felderhoff, Thomas; Sauren, Barthel; Bootsveld, Andreas; Buellesfeld, Lutz; Iversen, Stein

    2005-12-01

    Percutaneous aortic valve replacement is a new technology for the treatment of patients with significant aortic valve stenosis. We present the first report on a human implantation of a self-expanding aortic valve prosthesis, which is composed of three bovine pericardial leaflets inserted within a self-expanding nitinol stent. The 73-year-old woman presented with severe symptomatic aortic valve stenosis (mean transvalvular gradient of 45 mmHg; valve area of 0.7 cm2). Surgical valve replacement had been declined for the patient because of comorbidities, including previous bypass surgery. A retrograde approach via the common iliac artery was used for valve deployment. The contralateral femoral vessels were used for a temporary extracorporal circulation, unloading the left ventricle during the actual stent expansion. Clinical, hemodynamic, and echocardiographic outcomes were assessed serially during the procedure. Clinical and echocardiographic follow-up at day 1, 2, and 14 post procedure was performed to evaluate the short-term outcome. The prosthesis was successfully deployed within the native aortic valve, with accurate and stable positioning and with no impairment of the coronary artery or vein graft blood flow. 2D and doppler echo immediately after device deployment showed a significant reduction in transaortic mean pressure gradient (from 45 to 8 mmHg) without evidence of aortic or mitral valve insufficiency. The clinical status has then significantly improved. These results remained unchanged up to the day 14 follow-up. This case report demonstrates a successful percutaneous implantation of a self-expanding aortic valve prosthesis with remarkable functional and clinical improvements in the acute and short-term outcome. Copyright (c) 2005 Wiley-Liss, Inc.

  15. Percutaneous implantation of self-expandable aortic valve in high risk patients with severe aortic stenosis: The first experiences in Serbia

    Directory of Open Access Journals (Sweden)

    Nedeljković Milan A.

    2016-01-01

    Full Text Available Background/Aim. Aortic stenosis (AS is the most common valvular heart disease in elderly people, with rather poor prognosis in symptomatic patients. Surgical valve replacement is the therapy of choice, but a significant number of patients cannot undergo surgical procedure. We presented initial experience of transcatheter aortic valve implantation (TAVI performed in Catheterization Laboratory of the Clinic for Cardiology, Clinical Center of Serbia. Methods. The procedures were performed in 5 patients (mean age 76 ± 6 years, 2 males, 3 female with severe and symptomatic AS with contraindication to surgery or high surgical risk. The decision to perform TAVI was made by the heart team. Pre-procedure screening included detailed clinical and echocardiographic evaluation, coronary angiography and computed tomography scan. In all the patients we implanted a self-expandable aortic valve (Core Valve, Medtronic, USA. Six months follow-up was available for all the patients. Results. All interventions were successfully performed without significant periprocedural complications. Immediate hemodynamic improvement was obtained in all the patients (peak gradient 94.2 ± 27.6 to 17.6 ± 5.2 mmHg, p < 0.001, mean pressure gradient 52.8 ± 14.5 to 8.0 ± 2.1 mmHg, p < 0.001. None of the patients developed heart block, stroke, vascular complication or significant aortic regurgitation. After 6 months, the survival was 100% with New York Heart Association (NYHA functional improvement in all the patients. Conclusion. This successful initial experience provides a solid basis to treat larger number of patients with symptomatic AS and high surgical risk who are left untreated. [Projekat Ministarstva nauke Republike Srbije, br. ON 175 020

  16. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients.

    Science.gov (United States)

    Misterski, Marcin; Puślecki, Mateusz; Grygier, Marek; Olasińska-Wiśniewska, Anna; Lesiak, Maciej; Araszkiewicz, Aleksander; Perek, Barłomiej; Choręziak, Aneta; Lindner, Jacek; Komosa, Anna; Buczkowski, Piotr; Ligowski, Marcin; Katarzyński, Sławomir; Jemielity, Marek

    2017-06-01

    Transapical aortic valve implantation (TA-AVI) has been widely introduced for treatment of patients with severe aortic stenosis in the last decade. Here we report our first clinical experience with 10 patients using the second-generation transapical Symetis Acurate TA aortic valve designed for transapical implantation. To evaluate the results of transapical access in transcatheter aortic valve implantation (TAVI) among patients with unsuitable vascular access. All patients had been assessed by a local heart team and were disqualified from surgical aortic valve replacement (AVR) and the transfemoral TAVI approach. Mean age was 75.4 ±3.9 years (range: 68-80), with 20% being female. Logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and STS (Society of Thoracic Surgeons) were 15.4 ±8.9% and 20.5 ±4.5%, respectively. All implantations were performed successfully in the intra-annular and subcoronary position. There were no conversions to surgical AVR. All patients survived 30-day follow-up. No strokes or transient ischemic attacks were reported. There was no need for pacemaker implantation and none of the patients demonstrated moderate or significant paravalvular leakage. The mean aortic gradients improved significantly from a baseline of 57.0 ±19.2 mm Hg to a 30-day value of 14.2 ±4.1 mm Hg. Our initial clinical results indicate satisfactory functionality in patients after trans-apical implantation of the Symetis Acurate aortic valve. The procedure of implantation seems to be straightforward and may be considered in patients in whom a transfemoral approach is not a good option.

  18. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  19. Percutaneous treatment of adult isthmic aortic coarctation: acute and long-term clinical and imaging outcome with a self-expandable uncovered nitinol stent.

    Science.gov (United States)

    Kische, Stephan; D'Ancona, Giuseppe; Stoeckicht, Yannik; Ortak, Jasmin; Elsässer, Albrecht; Ince, Hüseyin

    2015-01-01

    To present perioperative and long-term results of percutaneous treatment of adult isthmic coarctation of the aorta by means of a self-expandable closed-web uncovered nitinol stent (Sinus-XL, Optimed, Esslingen, Germany). Preoperative, perioperative, and long-term clinical and computed tomographic angiography data were collected and analyzed prospectively. A total of 52 consecutive patients were treated with the Sinus-XL stent. Mean age was 36.6 (21-67) years, peak invasive trans-coarctation of the aorta gradient was 54.7 ± 9.9 mm Hg, and upper body hypertension unresponsive to medical treatment was present in all patients. Mean stent diameter and length were 24.2 mm (22-28 mm) and 70.4 mm (40-80 mm), respectively. Eight patients (15.4%) required coarctation of the aorta predilatation. All patients underwent poststent dilatation with a noncompliant balloon. Postoperative peak gradient (3.3 ± 2.5 mm Hg) was reduced significantly (P stent collapse and secondary migration and documented stability in aortic diameter (18.3 ± 2.7 mm). Thirty patients (57.7%) were completely weaned-off antihypertensive medications and their use dropped from 2.6 to 0.9 drugs/patient (P self-expandable uncovered stent is safe and durable. The peculiar stent design maintains adequate localized radial strength over time with minimal trauma on the adjacent aortic wall and negligible device-related complications. Blood pressure control optimization is immediate and persistent even at long-term follow-up. © 2015 American Heart Association, Inc.

  20. Outcomes for the Commercial Use of Self-Expanding Prostheses in Transcatheter Aortic Valve Replacement: A Report From the STS/ACC TVT Registry.

    Science.gov (United States)

    Sorajja, Paul; Kodali, Susheel; Reardon, Michael J; Szeto, Wilson Y; Chetcuti, Stanley J; Hermiller, James; Chenoweth, Sharla; Adams, David H; Popma, Jeffrey J

    2017-10-23

    The authors sought to compare the outcomes of commercial transcatheter aortic valve replacement (TAVR) with the repositionable Evolut R platform to those observed with the CoreValve device in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry. TAVR continues to evolve, with rapid adoption of iterative changes for commercial practice. Insight into the outcomes of this adoption is needed. Patients in the TVT Registry who had TAVR using a 23-, 26-, or 29-mm self-expanding prosthesis were enrolled. Site-reported events for procedural, in-hospital, and 30-day outcomes were examined. Between January 2014 and April 2016, 9,616 patients underwent TAVR with a self-expanding prosthesis with data entered in the TVT Registry. Compared with patients treated with CoreValve TAVR, those who received Evolut R TAVR had a lower STS-PROM score (8.0 ± 5.4% vs. 8.7 ± 5.3%; p < 0.001), more iliofemoral access (91.6% vs. 89.2%; p < 0.001), and more frequently had conscious sedation (27.4% vs. 12.7%; p < 0.001). With Evolut R TAVR, there was less need for a second prosthesis (2.2% vs. 4.5%; p < 0.001), less device migration (0.2% vs. 0.6%; p = 0.01), a lower incidence of moderate/severe paravalvular regurgitation (post-procedure, 4.4% vs. 6.2%; p < 0.001), and shorter median hospital stay (4.0 vs. 5.0 days; p < 0.001). Patients treated with Evolut R TAVR had greater device success (96.3% vs. 94.9%; p = 0.001). At 30 days, Evolut R patients had both lower mortality (3.7% vs. 5.3%; p < 0.001) and less need for a pacemaker (18.3% vs. 20.1%; p = 0.03). Commercial adoption of the Evolut R platform is associated with significant improvements in acute outcomes for patients undergoing TAVR for aortic stenosis. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Incidence, feasibility and outcome of percutaneous coronary intervention after transcatheter aortic valve implantation with a self-expanding prosthesis. Results from a single center experience.

    Science.gov (United States)

    Allali, Abdelhakim; El-Mawardy, Mohamed; Schwarz, Bettina; Sato, Takao; Geist, Volker; Toelg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-09-01

    Percutaneous coronary intervention (PCI) after transcatheter aortic valve implantation (TAVI) can become technically challenging after implantation of the self-expanding Medtronic CoreValve (MCV) device, which completely covers the aortic root. The aim of this study was to report on the incidence, feasibility and outcome of PCI after TAVI with the MCV device. Between 2007 and 2014, all patients subjected to PCI after MCV implantation in a single-center institutional TAVI database were retrospectively identified. Clinical, angiographic and procedural characteristics were reviewed and analyzed. We identified a total of 17 patients (5.7%) treated with 24 PCI procedures for 29 lesions at a median of 17.7months (range 1-72) after MCV implantation. The mean age was 79.7±6.8years and the mean logistic EuroSCORE was 30.3%±18.9%. Nine procedures were performed for patients with acute coronary syndrome. 89.6% of the treated lesions were of type B2/C and 79.3% were de novo ones. A median of one guiding catheter was necessary to intubate the target coronary ostium (range 1-10) and 95% of the lesions on the left coronary artery were treated through a Judkins catheter. In one primary PCI for STEMI the intubation of the right coronary ostium was not successful. Final procedural success was obtained in 95.8%, and peri-procedural death occurred in one patient. The need for PCI after MCV is not uncommon and is mostly related to coronary artery disease progression. PCI after MCV is usually feasible and safe, but coronary intubation in an emergency setting can be challenging. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  3. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  4. Topography of Aortic Bifurcation in a Black Kenyan Population ...

    African Journals Online (AJOL)

    After removal of abdominal viscera, peritoneum, fibrofatty connective tissue, inferior vena cava was removed to expose the termination of abdominal aorta. Vertebral level, angle and asymmetry of bifurcation were recorded. Data were analysed by SPSS version 17.0 for windows and are presented in tables and bar charts.

  5. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  6. The Aortic Bifurcation Angle as a Factor in Application of the Outback for Femoropopliteal Lesions in Ipsilateral Versus Contralateral Approaches.

    Science.gov (United States)

    Raskin, Daniel; Khaitovich, Boris; Balan, Shmuel; Silverberg, Daniel; Halak, Moshe; Rimon, Uri

    2018-01-01

    To assess the technical success of the Outback reentry device in contralateral versus ipsilateral approaches for femoropopliteal arterial occlusion. A retrospective review of patients treated for critical limb ischemia (CLI) using the Outback between January 2013 and July 2016 was performed. Age, gender, length and site of the occlusion, approach site, aortic bifurcation angle, and reentry site were recorded. Calcification score was assigned at both aortic bifurcation and reentry site. Technical success was assessed. During the study period, a total of 1300 endovascular procedures were performed on 489 patients for CLI. The Outback was applied on 50 femoropopliteal chronic total occlusions. Thirty-nine contralateral and 11 ipsilateral antegrade femoral were accessed. The device was used successfully in 41 patients (82%). There were nine failures, all in the contralateral approach group. Six due to inability to deliver the device due to acute aortic bifurcation angle and three due to failure to achieve luminal reentry. Procedural success was significantly affected by the aortic bifurcation angle (p = 0.013). The Outback has high technical success rates in treatment of femoropopliteal occlusion, when applied from either an ipsi- or contralateral approach. When applied in contralateral access, acute aortic bifurcation angle predicts procedural failure.

  7. Mortality and complications after aortic bifurcated bypass procedures for chronic aortoiliac occlusive disease

    DEFF Research Database (Denmark)

    Bredahl, Kim; Jensen, Leif Panduro; Schroeder, Torben V

    2015-01-01

    skills, particularly because open surgery is increasingly used in those patients who are unsuitable for endovascular repair and hence technically more demanding. We assessed the early outcome after aortic bifurcated bypass procedures during two decades of growing endovascular activity and identified...... preoperative risk factors. METHODS: Data on patients with chronic limb ischemia were prospectively collected during a 20-year period (1993 to 2012). The data were obtained from the Danish Vascular Registry, assessed, and merged with data from The Danish Civil Registration System. RESULTS: We identified 3623...... aortobifemoral and 144 aortobiiliac bypass procedures. The annual caseload fell from 323 to 106 during the study period, but the 30-day mortality at 3.6% (95% confidence interval [CI], 3.0-4.1) and the 30-day major complication rate remained constant at 20% (95% CI, 18-21). Gangrene (odds ratio [OR], 3.3; 95% CI...

  8. Influence of Iliac Stenotic Lesions on Blood Flow Patterns Near a Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Stent Configuration

    NARCIS (Netherlands)

    Jebbink, Erik Groot; Engelhard, Stefan; Lajoinie, Guillaume; de Vries, Jean-Paul P.M.; Versluis, Michel; Reijnen, Michel M.P.J.

    2017-01-01

    Purpose: To investigate the effect of distal stenotic lesions on flow patterns near a covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration used in the treatment of aortoiliac occlusive disease. Method: Laser particle image velocimetry measurements were performed using

  9. Tratamento das afecções da aorta com a primeira geração de stents auto-expansíveis Aortic diseases treatment with a first generation of self expanding stent-grafts

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    2001-09-01

    ,57%, com 70,15% dos pacientes livre de eventos em 33 meses de seguimento, tornando o método factível e diminuindo a mortalidade no tratamento cirúrgico das dissecções agudas e crônicas do tipo B.INTRODUCTION: The authors describe the implantation of an endovascular self-expanding stents grafts at 33 months of follow-up. The use can be a new alternative for the treatment of descending aortic dissections and aneurysms disease. MATERIAL AND METHODS: From April 1998 to November 2000 (32 months, 37 endovascular stent grafts were implanted, 21 in acute dissections type B, 7 in acute dissections type A and 9 in chronic dissections type B and aneurysms ones. The age varied between 39 and 79 years (mean=57.94 ± 1.91 years, considering that 64.86% were male patients. The patients were submitted to median esternotomy, extracorporeal circulation (ECC, with deep hipothermia (18-20ºC, total circulatory arrest (TCA, and retrograde cerebral perfusion (RCP. The transverse aorta was incised and the stent was implanted in the descending proximal aorta with the aid sometimes of aortoscopy. The times of ECC, aortic clamping, TCA, RCP, rewarming, mechanic ventilation, hospitalization, trans and post-operative bleeding, blood replacement, events curve and survival curve were analyzed. RESULTS: The hospital mortality (30 days was 13.51%; 32 have been followed up from 1 to 33 months, 70.7% are free of events and survival curve with 63.19% (33 months. CONCLUSIONS: The implant of self-expanding intraluminal stent grafts presented has lower hospital mortality in the acute phase and follow-up in acute aortic dissections type B (10% than clinical treatment (IRAD. In spite of the small sample the procedure is promising and needs longer follow-up.

  10. Effect of aorto-iliac bifurcation and iliac stenosis on flow dynamics in an abdominal aortic aneurysm

    Science.gov (United States)

    Patel, Shivam; Usmani, Abdullah Y.; Muralidhar, K.

    2017-06-01

    Physiological flows in rigid diseased arterial flow phantoms emulating an abdominal aortic aneurysm (AAA) under rest conditions with aorto-iliac bifurcation and iliac stenosis are examined in vitro through 2D PIV measurements. Flow characteristics are first established in the model resembling a symmetric AAA with a straight outlet tube. The influence of aorto-iliac bifurcation and iliac stenosis on AAA flow dynamics is then explored through a comparison of the nature of flow patterns, vorticity evolution, vortex core trajectory and hemodynamic factors against the reference configuration. Specifically, wall shear stress and oscillatory shear index in the bulge portion of the models are of interest. The results of this investigation indicate overall phenomenological similarity in AAA flow patterns across the models. The pattern is characterized by a central jet and wall-bounded vortices whose strength increases during the deceleration phase as it moves forward. The central jet impacts the wall of AAA at its distal end. In the presence of an aorto-iliac bifurcation as well as iliac stenosis, the flow patterns show diminished strength, expanse and speed of propagation of the primary vortices. The positions of the instantaneous vortex cores, determined using the Q-function, correlate with flow separation in the bulge, flow resistance due to a bifurcation, and the break in symmetry introduced by a stenosis in one of the legs of the model. Time-averaged WSS in a healthy aorta is around 0.70 N m-2 and is lowered to the range ±0.2 N m-2 in the presence of the downstream bifurcation with a stenosed common iliac artery. The consequence of changes in the flow pattern within the aneurysm on disease progression is discussed.

  11. Effect of aorto-iliac bifurcation and iliac stenosis on flow dynamics in an abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Patel, Shivam; Usmani, Abdullah Y; Muralidhar, K

    2017-01-01

    Physiological flows in rigid diseased arterial flow phantoms emulating an abdominal aortic aneurysm (AAA) under rest conditions with aorto-iliac bifurcation and iliac stenosis are examined in vitro through 2D PIV measurements. Flow characteristics are first established in the model resembling a symmetric AAA with a straight outlet tube. The influence of aorto-iliac bifurcation and iliac stenosis on AAA flow dynamics is then explored through a comparison of the nature of flow patterns, vorticity evolution, vortex core trajectory and hemodynamic factors against the reference configuration. Specifically, wall shear stress and oscillatory shear index in the bulge portion of the models are of interest. The results of this investigation indicate overall phenomenological similarity in AAA flow patterns across the models. The pattern is characterized by a central jet and wall-bounded vortices whose strength increases during the deceleration phase as it moves forward. The central jet impacts the wall of AAA at its distal end. In the presence of an aorto-iliac bifurcation as well as iliac stenosis, the flow patterns show diminished strength, expanse and speed of propagation of the primary vortices. The positions of the instantaneous vortex cores, determined using the Q -function, correlate with flow separation in the bulge, flow resistance due to a bifurcation, and the break in symmetry introduced by a stenosis in one of the legs of the model. Time-averaged WSS in a healthy aorta is around 0.70 N m −2 and is lowered to the range ±0.2 N m −2 in the presence of the downstream bifurcation with a stenosed common iliac artery. The consequence of changes in the flow pattern within the aneurysm on disease progression is discussed. (paper)

  12. Effect of aorto-iliac bifurcation and iliac stenosis on flow dynamics in an abdominal aortic aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Shivam; Usmani, Abdullah Y; Muralidhar, K, E-mail: kmurli@iitk.ac.in [Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India)

    2017-06-15

    Physiological flows in rigid diseased arterial flow phantoms emulating an abdominal aortic aneurysm (AAA) under rest conditions with aorto-iliac bifurcation and iliac stenosis are examined in vitro through 2D PIV measurements. Flow characteristics are first established in the model resembling a symmetric AAA with a straight outlet tube. The influence of aorto-iliac bifurcation and iliac stenosis on AAA flow dynamics is then explored through a comparison of the nature of flow patterns, vorticity evolution, vortex core trajectory and hemodynamic factors against the reference configuration. Specifically, wall shear stress and oscillatory shear index in the bulge portion of the models are of interest. The results of this investigation indicate overall phenomenological similarity in AAA flow patterns across the models. The pattern is characterized by a central jet and wall-bounded vortices whose strength increases during the deceleration phase as it moves forward. The central jet impacts the wall of AAA at its distal end. In the presence of an aorto-iliac bifurcation as well as iliac stenosis, the flow patterns show diminished strength, expanse and speed of propagation of the primary vortices. The positions of the instantaneous vortex cores, determined using the Q -function, correlate with flow separation in the bulge, flow resistance due to a bifurcation, and the break in symmetry introduced by a stenosis in one of the legs of the model. Time-averaged WSS in a healthy aorta is around 0.70 N m{sup −2} and is lowered to the range ±0.2 N m{sup −2} in the presence of the downstream bifurcation with a stenosed common iliac artery. The consequence of changes in the flow pattern within the aneurysm on disease progression is discussed. (paper)

  13. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  14. Subclinical leaflet thickening and stent frame geometry in self-expanding transcatheter heart valves

    DEFF Research Database (Denmark)

    Fuchs, Andreas; De Backer, Ole; Brooks, Matthew

    2017-01-01

    AIMS: This study aimed to assess the potential relationship between subclinical leaflet thickening and stent frame geometry in patients who underwent aortic valve replacement with a self-expanding transcatheter heart valve (THV). METHODS AND RESULTS: Seventy-five patients with a self-expanding THV....... CONCLUSIONS: Regional THV stent frame underexpansion is associated with an increased risk of leaflet thickening. Post-dilatation of self-expanding THV as well as a supra-annular valve position seem to reduce the occurrence of this phenomenon....

  15. Hybrid treatment of bullet embolism at the abdominal aortic bifurcation, complicated with thoracoabdominal aorta pseudoaneurysm and common iliac artery occlusion: case report

    Directory of Open Access Journals (Sweden)

    Patrick Bastos Metzger

    2014-03-01

    Full Text Available Embolization due to a firearm projectile entering the bloodstream is a rare event that is unlikely to be suspected during initial treatment of trauma patients. We describe and discuss a case of bullet embolism of the abdominal aortic bifurcation, complicated by a pseudoaneurysm of the thoracoabdominal aorta and occlusion of the right common iliac artery, but successfully treated using a combination of endovascular methods and conventional surgery.

  16. A multiscale modelling approach to understand atherosclerosis formation: A patient-specific case study in the aortic bifurcation

    Science.gov (United States)

    Alimohammadi, Mona; Pichardo-Almarza, Cesar; Agu, Obiekezie; Díaz-Zuccarini, Vanessa

    2017-01-01

    Atherogenesis, the formation of plaques in the wall of blood vessels, starts as a result of lipid accumulation (low-density lipoprotein cholesterol) in the vessel wall. Such accumulation is related to the site of endothelial mechanotransduction, the endothelial response to mechanical stimuli and haemodynamics, which determines biochemical processes regulating the vessel wall permeability. This interaction between biomechanical and biochemical phenomena is complex, spanning different biological scales and is patient-specific, requiring tools able to capture such mathematical and biological complexity in a unified framework. Mathematical models offer an elegant and efficient way of doing this, by taking into account multifactorial and multiscale processes and mechanisms, in order to capture the fundamentals of plaque formation in individual patients. In this study, a mathematical model to understand plaque and calcification locations is presented: this model provides a strong interpretability and physical meaning through a multiscale, complex index or metric (the penetration site of low-density lipoprotein cholesterol, expressed as volumetric flux). Computed tomography scans of the aortic bifurcation and iliac arteries are analysed and compared with the results of the multifactorial model. The results indicate that the model shows potential to predict the majority of the plaque locations, also not predicting regions where plaques are absent. The promising results from this case study provide a proof of concept that can be applied to a larger patient population. PMID:28427316

  17. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-05-15

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} 10.82% (type A) and 13.80 {+-} 6.94% (type B) ({rho} < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 {+-} 10.84% (type A). 87.58 {+-} 7.36% (type B) ({rho} = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern.

  18. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung

    2008-01-01

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 ± 10.82% (type A) and 13.80 ± 6.94% (type B) (ρ < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 ± 10.84% (type A). 87.58 ± 7.36% (type B) (ρ = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern

  19. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  20. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  1. Factors leading to tracheobronchial self-expandable metallic stent fracture.

    Science.gov (United States)

    Chung, Fu-Tsai; Lin, Shu-Min; Chen, Hao-Cheng; Chou, Chun-Liang; Yu, Chih-Teng; Liu, Chien-Ying; Wang, Chun-Hua; Lin, Horng-Chyuan; Huang, Chien-Da; Kuo, Han-Pin

    2008-11-01

    This retrospective study was to determine factors that contribute to self-expandable metallic stent fracture in patients with tracheobronchial disease. From 2001 to 2006, 139 patients (age, 62.1 +/- 15.4 years; range, 23-87 years) with benign (n = 62) and malignant (n = 77) tracheobronchial disease received 192 Ultraflex (Boston Scientific, Natick, Mass) self-expandable metallic stents (98 in patients with benign disease and 94 in patients with malignant disease). Seventeen fractured self-expandable metallic stents were found; the incidence was 12.2% (17/139 patients) among patients with tracheobronchial disease. Tortuous airway (odds ratio, 4.06; 95% confidence interval, 1.04-18.34; P = .04) independently predicted self-expandable metallic stent fracture. Most self-expandable metallic stent fractures (64.7%, 11/17) were detected 500 to 1000 days after self-expandable metallic stent implantation. Clinical presentations for patients with fractured self-expandable metallic stents included dyspnea exacerbation (70.6%, 12/17) and cough (23.5%, 4/17). Self-expandable metallic stent fracture is not uncommon in patients with tracheobronchial disease. Tortuous airway is an independent predictor for it. Although management of the fractured self-expandable metallic stent in our study was feasible and safe, self-expandable metallic stents should be restricted to a more select population.

  2. In Vitro Comparison of Self-Expanding Versus Balloon-Expandable Stents in a Human Ex Vivo Model

    International Nuclear Information System (INIS)

    Grenacher, Lars; Rohde, Stefan; Gaenger, Ellen; Deutsch, Jochen; Kauffmann, Guenter W.; Richter, Goetz M.

    2006-01-01

    The objective was to compare the radial strength and expansile precision of self-expanding stents and balloon-expandable stents in a human cadaver bifurcation model. Seven different self-expanding (LUMINEXX, JOSTENT SelfX, JOSTENT SelfX hrf, Sinus-Repo, Sinus SuperFlex, Easy Wallstent, SMART) and four different balloon-expandable stent models (Palmaz, Sinus Stent, SAXX Medium, JOSTENT peripheral), each type 10 stents (total n = 110 stents) were implanted into the common iliac arteries of human cadaver corpses. The maximum stent diameter was 10 mm for all models. After stent implantation, the specimens were filled with silicone caoutchouc. After 24 h, the vascular walls including the stents were removed from the hardened casts. Diameters were taken and the weight of the cast cylinders was measured in air and in purified water to calculate the volume of the bodies (according to Archimedes Law) as a relative but precise degree for the radial strength of the implanted stents. The cylindrical casts of the self-expanding stents showed lower mean diameters (8.2 ± 1.0 mm) and mean volumes (0.60 ± 0.14 ml/cm) than in the balloon-expandable stent group (10.1 ± 0.3 mm and 0.71 ± 0.04 ml/cm, respectively; p < 0.01). The nominal maximum diameter of 10 mm was not achieved in any of the self-expanding stents, but this was achieved in more than 70% (29/40) of the balloon-expandable stent specimens (p < 0.05). The variation between achieved volumes was significantly larger in self-expanding (range: 0.23-0.78 ml/cm) than in balloon-expandable stents (range: 0.66-0.81 ml/cm; p < 0.05). Self-expanding stents presented considerably lower radial expansion force and lower degree of precision than balloon-expandable stents

  3. Self-Expanding, Tough Biodegradable Elastomers for Wound Stasis

    Science.gov (United States)

    2015-08-06

    the civilian setting, with no effective therapies available at point of injury. We previously reported that a self- expanding polyurethane foam...setting, with no effective therapies available at point of injury. We previously reported that a self-expanding polyurethane foam significantly...care in accor- dance with the Guide of the Care and Use of Laboratory Ani- mals (Health, 2011 #17). 2.2. Instrumentation and monitoring All swine (n

  4. Esophagorespiratory fistula: treatment with self-expanding covered stent

    International Nuclear Information System (INIS)

    Zang Jian; Dou Yongchong; Wang Zheng; Kong Jian

    2002-01-01

    Objective: To evaluate self-expanding covered stent in the management of esophagorespiratory fistula. Methods: A self-expanding esophageal covered stent was implanted under fluoroscopic guidance in 13 patients with esophagorespiratory fistula. In this series patients aged 31-73 years (60.2 years in average). All patients had a pre-procedure fast of 6-41 days (17.3 days in average), in which 12 patients had pulmonary infection. Results: All fistulas were excluded and swallowing function was restored. No stend-related complication was observed. Pulmonary infection was managed in 10 patients out of 13. The mean survived time was 33.3 wks (1-178 wks) in follow-up. Conclusion: Covered self-expanding stent implantation is a safe and effective treatment of ERF

  5. Esophagojejunal anastomotic leak managed with self expandable metallic stent

    Directory of Open Access Journals (Sweden)

    Arvind Madurandagam Annapillai

    2013-01-01

    Full Text Available Esophagealjejunal anastomotic leak after gastrectomy is a serious surgical emergency with high mortality. This report describes a 57-year-old male with esophagojejunal anastomotic leak following total gastrectomy for gastric cancer and was managed successfully with self-expandable metallic stent. To our knowledge this is the first such report from India. This case report highlights the need of interdisciplinary coordination in managing this difficult clinical situation. Endotherapy with self-expandable metallic stent (SEM provided twin benefits of improving respiratory embarrassment and the joy of eating. Therapy of such difficult cases must be individualized; however, and SEM stent usage is a viable option

  6. Functional Self-Expandable Metal Stents in Biliary Obstruction

    Science.gov (United States)

    Kwon, Chang-Il; Ko, Kwang Hyun; Hahm, Ki Baik

    2013-01-01

    Biliary stents are widely used not only for palliative treatment of malignant biliary obstruction but also for benign biliary diseases. Each plastic stent or self-expandable metal stent (SEMS) has its own advantages, and a proper stent should be selected carefully for individual condition. To compensate and overcome several drawbacks of SEMS, functional self-expandable metal stent (FSEMS) has been developed with much progress so far. This article looks into the outcomes and defects of each stent type for benign biliary stricture and describes newly introduced FSEMSs according to their functional categories. PMID:24143314

  7. Malignant biliary obstruction: percutaneous use of self-expandable stents

    NARCIS (Netherlands)

    Laméris, J. S.; Stoker, J.; Nijs, H. G.; Zonderland, H. M.; Terpstra, O. T.; van Blankenstein, M.; Schütte, H. E.

    1991-01-01

    A total of 83 self-expandable metallic stents were placed percutaneously in 69 patients for palliation of malignant biliary obstruction. Stent diameter was 1 cm; length, 3.5-10.5 cm. Of the 41 patients with common bile duct obstruction, 27 died 0.2-12 months (median, 3.2 months) after stent

  8. Self-expanding/shrinking structures by 4D printing

    Science.gov (United States)

    Bodaghi, M.; Damanpack, A. R.; Liao, W. H.

    2016-10-01

    The aim of this paper is to create adaptive structures capable of self-expanding and self-shrinking by means of four-dimensional printing technology. An actuator unit is designed and fabricated directly by printing fibers of shape memory polymers (SMPs) in flexible beams with different arrangements. Experiments are conducted to determine thermo-mechanical material properties of the fabricated part revealing that the printing process introduced a strong anisotropy into the printed parts. The feasibility of the actuator unit with self-expanding and self-shrinking features is demonstrated experimentally. A phenomenological constitutive model together with analytical closed-form solutions are developed to replicate thermo-mechanical behaviors of SMPs. Governing equations of equilibrium are developed for printed structures based on the non-linear Green-Lagrange strain tensor and solved implementing a finite element method along with an iterative incremental Newton-Raphson scheme. The material-structural model is then applied to digitally design and print SMP adaptive lattices in planar and tubular shapes comprising a periodic arrangement of SMP actuator units that expand and then recover their original shape automatically. Numerical and experimental results reveal that the proposed planar lattice as meta-materials can be employed for plane actuators with self-expanding/shrinking features or as structural switches providing two different dynamic characteristics. It is also shown that the proposed tubular lattice with a self-expanding/shrinking mechanism can serve as tubular stents and grippers for bio-medical or piping applications.

  9. Square Stent: A New Self-Expandable Endoluminal Device and Its Applications

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Uchida, Barry; Timmermans, Hans; Keller, Frederick S.; Roesch, Josef

    2001-01-01

    The square stent is a new, simply constructed, self-expanding device that has recently been described. Compared with other stents, the square stent has a minimal amount of metal and thus requires a smaller-diameter catheter for introduction. Despite the small amount of metal present, the square stent has adequate expansile force. We have been evaluating the square stent for various interventional applications. In addition to the basic square stent, combinations of square stents and coverings for square stents were developed and evaluated to expand its uses and indications. One of the coverings tested is a new biomaterial: small intestinal submucosa (SIS). This paper will discuss the various applications of the square stent, which include a retrievable inferior vena cava filter, vascular occluder, graft adapter, and venous and aortic valves. In addition, we will review the important properties of SIS as a covering for the square stent

  10. Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils

    International Nuclear Information System (INIS)

    Bai Weixing; Jiang Xifeng; Li Tianxiao; Zhai Shuiting; Xue Jiangyu; Wang Ziliang; Cao Huicun

    2008-01-01

    Objective: To evaluate the preliminary experience of the combined self-expanding neurovascular stent (Neuroform stent) with detachable coils in the management of intracranial wide neck aneurysms. Methods: Self-expanding neurovascular stents with detachable coils were used in treating 27 intracranial wide neck aneurysms of 25 patients including cavernous segment ICA aneurysms in 3, ophthalmic arterial anemysm in 1, PcomA in 18, AcomA in 2, MCAM1 in 1, MCA bifurcation in 1, and basilar trunk in 1. Among them, 2 cases consisted of multi-aneurysms, 2 aneurysms coincide with absolute wide neck (> 4 mm) and 6 with comparatively wide neck (> 7 mm). Nemoform stents were deployed across the neck of aneurysm and detachable coils were released to embolize the aneurysm through stent mesh. Results: Twenty-six Neuroform stents were successfully deployed in 25 patients including 4 Neuroform II stents, and 22 Neurofom III stents(all combined with spring coils). Total occlusion was achieved in 7 patients with residual neck in 9 nearly complete occlusion and partial occlusion in 11. 2 patients were rebleeding and other 2 showed intra-stent thrombosis during the operations. The latter 2 included 1 with post-operative limb paraplegia and 1 died. Still another 1 had transient ischemic attack after the operation. Twenty-three patient recovered well. Twenty-four patients were under clinical followed up from 0.5 to 28 months with an average of 10.8 months. There was no bleeding. Three patients were angiographically followed up for 3-6 months after the procedure, with only 1 case of in-stent thrombosis and no change in other 2 aneurysms with neck remnant. Conclusions: The Neuroform stent is technically feasible and safe for treating intracranial wide neck aneurysms unsuitable for clipping because of its prevention for coil protruding into parent artery. The long term effect still need to be further investigated. (authors)

  11. Dynamic Bifurcations

    CERN Document Server

    1991-01-01

    Dynamical Bifurcation Theory is concerned with the phenomena that occur in one parameter families of dynamical systems (usually ordinary differential equations), when the parameter is a slowly varying function of time. During the last decade these phenomena were observed and studied by many mathematicians, both pure and applied, from eastern and western countries, using classical and nonstandard analysis. It is the purpose of this book to give an account of these developments. The first paper, by C. Lobry, is an introduction: the reader will find here an explanation of the problems and some easy examples; this paper also explains the role of each of the other paper within the volume and their relationship to one another. CONTENTS: C. Lobry: Dynamic Bifurcations.- T. Erneux, E.L. Reiss, L.J. Holden, M. Georgiou: Slow Passage through Bifurcation and Limit Points. Asymptotic Theory and Applications.- M. Canalis-Durand: Formal Expansion of van der Pol Equation Canard Solutions are Gevrey.- V. Gautheron, E. Isambe...

  12. Self expandable polytetrafluoroethylene stent for carotid blowout syndrome.

    Science.gov (United States)

    Tatar, E C; Yildirim, U M; Dündar, Y; Ozdek, A; Işik, E; Korkmaz, H

    2012-01-01

    Carotid blowout syndrome (CBS) is an emergency complication in patients undergoing treatment for head and neck cancers. The classical management of CBS is the ligation of the common carotid artery, because suturing is not be possible due to infection and necrosis of the field. In this case report, we present a patient with CBS, in whom we applied a self-expandable polytetrafluoroethylene (PTFE) stent and observed no morbidity. Endovascular stent is a life-saving technique with minimum morbidity that preserves blood flow to the brain. We believe that this method is preferable to ligation of the artery in CBS.

  13. Complication after self expandable metallic stent for esophageal cancer

    International Nuclear Information System (INIS)

    Nagahama, Takeshi; Maruyama, Michio; Kato, Kiyomi; Shinoura, Hiroshi; Hasegawa, Kumi; Takashima, Itaru; Ebuchi, Masakazu

    2003-01-01

    Major complications after placement of esophageal stent and airway stent were reviewed and evaluated. Four patients, including two patients with perforations and two patients with fistula formation, developed major complications after placement of a self expandable metallic stent. Two patients underwent additional radiation to improve stricture after stent placement. In one patient, stent placement was selected to improve esophageal stricture that occurred after radical radiation therapy. In one patient, migration of stent into the lesion caused a perforation. It can be concluded that additional radiation after stent placement increases the risk of complication. Stent migration also can lead to the risk of perforation. (author)

  14. Malignant Gastroduodenal Obstruction: Treatment with Self-Expanding Uncovered Wallstent

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Binkert, Christoph A.; Schoch, Eric; Sautter, Thomas; Jost, Res; Zollikofer, Christoph L.

    2009-01-01

    Purpose: To retrospectively evaluate the clinical effectiveness of a self-expanding uncovered Wallstent in patients with malignant gastroduodenal obstruction. Materials and Methods: Under combined endoscopic and fluoroscopic guidance, 29 patients with a malignant gastroduodenal stenosis were treated with a self-expanding uncovered metallic Wallstent. A dysphagia score was assessed before and after the intervention to measure the success of this palliative therapy. The dysphagia score ranged between grade 0 to grade 4: grade 0 = able to tolerate solid food, grade 1 = able to tolerate soft food, grade 2 = able to tolerate thick liquids, grade 3 = able to tolerate water or clear fluids, and grade 4 = unable to tolerate anything perorally. Stent patency and patients survival rates were calculated. Results: The insertion of the gastroduodenal stent was technically successful in 28 patients (96.5%). After stenting, 25 patients (86.2%) showed clinical improvement by at least one score point. During follow-up, 22 (78.5%) of 28 patients showed no stent occlusion until death and did not have to undergo any further intervention. In six patients (20.6%), all of whom were treated with secondary stent insertions, occlusion with tumor ingrowth and/or overgrowth was observed after the intervention. The median period of primary stent patency in our study was 240 days. Conclusion: Placement of an uncovered Wallstent is clinically effective in patients with malignant gastroduodenal obstruction. Stent placement is associated with high technical success, good palliation effect, and high durability of stent function.

  15. Novel biliary self-expanding metal stents: indications and applications.

    Science.gov (United States)

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  16. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  17. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  18. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  19. Treatment of aortic stenosis with a self-expanding transcatheter valve

    DEFF Research Database (Denmark)

    Linke, Axel; Wenaweser, Peter; Gerckens, Ulrich

    2014-01-01

    and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12...

  20. Endoscopic removal of malfunctioning biliary self-expandable metallic stents.

    Science.gov (United States)

    Familiari, Pietro; Bulajic, Milutin; Mutignani, Massimiliano; Lee, Linda S; Spera, Gianluca; Spada, Cristiano; Tringali, Andrea; Costamagna, Guido

    2005-12-01

    Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal.

  1. [Self-expanding nitinol stents in proximal tracheal stenosis].

    Science.gov (United States)

    Hafner, B; Mann, W; Heussel, C P; Scherhag, A; Schlegel, J; Kauczor, H U

    2000-03-01

    The use of silicone- or metal stents in stenosis of the distal trachea and the bronchial system is a customary procedure [1-4], for example after tumor invasion or cicatricial stenosis after transplantation. In the proximal part of the trachea, on smaller, short and soft strictures we try to stabilise the trachea by the implantation of rings. Other methods are tracheal plasty or transverse tracheal resectomy [5-7]. In the case of longer or nearer subglottal stenoses the positioning of self-expanding nitinol stents has proven a simple, gentle and well-tolerated alternative procedure even in very serious disorders [1, 8, 9]. These stents can be placed in short narcosis under endoscopic control without great strain on the patient. We placed nitinol-stents in the proximal part of the trachea in eleven cases. In five cases dyspnoea caused by a tracheal collapse improved. In two further cases a tracheal stenosis with massive granulation tissue and cicatricial pull under an inlaid tracheal cannula was removed and the tracheostoma was closed. In four cases a solid, scarred and cartilaginous stenosis in the area of the cricoid and the upper tracheal rings was widened with laser and later on stented. Over an observation time of two years no complications showed safe one case in which a directly postoperative dislocation was repositioned quickly. The patients live without restrictions through the tracheal stenosis or a tracheostoma. In the best possible case epithelialization over the metal meshes develops so that a nearly normal mucus transportation is possible [1, 10-12].

  2. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases

    NARCIS (Netherlands)

    van Halsema, Emo E.; Wong Kee Song, Louis M.; Baron, Todd H.; Siersema, Peter D.; Vleggaar, Frank P.; Ginsberg, Gregory G.; Shah, Pari M.; Fleischer, David E.; Ratuapli, Shiva K.; Fockens, Paul; Dijkgraaf, Marcel G. W.; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E.

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six

  3. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  4. Comparison of covered and uncovered self-expandable stents in the treatment of malignant biliary obstruction.

    Science.gov (United States)

    Flores Carmona, Diana Yamel; Alonso Lárraga, Juan Octavio; Hernández Guerrero, Angélica; Ramírez Solís, Mauro Eduardo

    2016-05-01

    Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.

  5. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    OpenAIRE

    Mohamed Shaker; Ahmed Deif; Amr Abdelaal

    2016-01-01

    Objectives: To evaluate the role of fluoroscopic guided self expanding metallic stents in the management of dysphagia caused by malignant esophageal strictures. Materials and methods: During the period between April 2010 and October 2012, 31 patients with malignant esophageal strictures were subjected to fluoroscopic guided self expanding metallic stent application. The study included 22 males and 9 females ranging in age between 22 and 75 years old with mean age of 56.8 years. Lesions wer...

  6. Esophageal carcinoma treatment with self-expanding covered stent implanted in esophagus

    International Nuclear Information System (INIS)

    Liu Mingguo; Ji Yan; He Nengwei

    2006-01-01

    Objective: To investigate the clinical significance of the treatment to esophageal cancer by self- expanding covered stent implanted into esophagus. Methods: Under fluoroscopic guidance and with guidance wire , 20 self-expanding covered stents were implanted into stenotic part of esophagus to recanalize the esophagus, then follow up to observe the clinical symptom improved. Results: Technical success was obtained 20 cases without any complication. Clinical symptom were improved in shot time. Conclusions: self-expanding covered stent is implanted in stenotic part of esophageal carcinoma to treat esophageal stenosis and enable to improved clinical symptom in shot time, if combined with transcatheter arterial infusion and embolization, Radiotherapy, Chinese medical treatment, it enable to lengthen life time remarkably. (authors)

  7. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2012-01-01

    Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish....... Interventions(s). Self-expanding metal stent placement. Main Outcome Measures. Procedural success, clinical success, and safety. Results. Procedural success was 98.4% (251). Clinical success rates were 87.8% at 30 days, 89.7% at 3 months, 92.8% at 6 months, and 96% at 12 months. Overall perforation rate was 5...... for patients with malignant colonic obstruction should be self-expanding metal stent placement due to high rates of technical success and efficacy in symptom palliation and few complications....

  8. Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.

    Science.gov (United States)

    Waldthaler, Alexander; Schütte, Kerstin; Weigt, Jochen; Kropf, Siegfried; Malfertheiner, Peter; Kahl, Stefan

    2013-01-10

    Insertion of a self-expandable metal stent is still controversial for treatment of benign common bile duct stenosis but can be a valuable alternative to surgical treatment. Aim of our study was to analyze the efficacy of covered and uncovered self-expandable metal stent in patients with chronic pancreatitis and common bile duct stenosis. Twenty patients with common bile duct stenosis due to alcoholic chronic pancreatitis were retrospective analyzed. All patients had advanced chronic pancreatitis, presenting with calcifications in pancreatic head. Uncovered self-expandable metal stent (uSEMS) were used in 11 patients (3 females, 8 males) while in 9 patients (3 females, 6 males) partially covered self-expandable metal stent (cSEMS) were inserted. All patients treated with self-expandable metal stent had contraindications for surgery. Overall mean follow up time was 155 weeks: 206 (52-412) weeks in uSEMS, and 93 (25-233) weeks in cSEMS, respectively. Stent patency was in mean 118 weeks: 159 (44-412) weeks in uSEMS and 67 (25-150) weeks in cSEMS (P=0.019). In the uSEMS group, reintervention was necessary in 5 patients (45%) due to stent obstruction, whereas in the cSEMS group 4 patients (44%) needed reintervention (2 obstructions, 2 migration). Stent migration is an early complication, compared to obstruction (P<0.05), and in cSEMS obstruction occurred significantly earlier compared to uSEMS (P<0.05). Patency of uSEMS was significantly longer compared to partially cSEMS. Available self-expandable metal stent, unfortunately, do not meet the demands on successful treatment of benign common bile duct stenosis.

  9. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    Science.gov (United States)

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Directory of Open Access Journals (Sweden)

    Ahmed Abdel Samie

    2012-01-01

    Full Text Available Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES, and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause.

  11. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Science.gov (United States)

    Abdel Samie, Ahmed; Theilmann, Lorenz

    2012-01-01

    Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs) have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES), and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause. PMID:22761543

  12. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer.

    Science.gov (United States)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho Young; Kim, Pyeong Hwa; Park, Jung Hoon

    2017-07-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. © 2017 The Korean Academy of Medical Sciences.

  13. Renal Transplant Ureteral Stenosis: Treatment by Self-Expanding Metallic Stent

    International Nuclear Information System (INIS)

    Cantasdemir, Murat; Kantarci, Fatih; Numan, Furuzan; Mihmanli, Ismail; Kalender, Betul

    2003-01-01

    We report the use of a metallic stent in a transplant ureteral stenosis. A 28-year-old man with chronic renal failure due to chronic pyelonephritis, who received a living-donor renal transplant, presented with transplant ureteral stenosis. The stenosis was unresponsive to balloon dilation and was treated by antegrade placement of a self-expanding Memotherm stent. The stentedureter stayed patent for 3 years. It may be reasonable to treat post-transplant ureteral stenosis resistant to balloon dilation with self-expanding metallic stents. However, long-term follow-up is required to evaluate the efficacy of this treatment

  14. Unfolding the Riddling Bifurcation

    DEFF Research Database (Denmark)

    Maistrenko, Yu.; Popovych, O.; Mosekilde, Erik

    1999-01-01

    We present analytical conditions for the riddling bifurcation in a system of two symmetrically coupled, identical, smooth one-dimensional maps to be soft or hard and describe a generic scenario for the transformations of the basin of attraction following a soft riddling bifurcation.......We present analytical conditions for the riddling bifurcation in a system of two symmetrically coupled, identical, smooth one-dimensional maps to be soft or hard and describe a generic scenario for the transformations of the basin of attraction following a soft riddling bifurcation....

  15. Self-expanding metal stents in benign biliary strictures due to chronic pancreatitis

    NARCIS (Netherlands)

    van Berkel, A. M.; Cahen, D. L.; van Westerloo, D. J.; Rauws, E. A.; Huibregtse, K.; Bruno, M. J.

    2004-01-01

    Background and Study Aims: In selected patients with chronic pancreatitis in whom conventional plastic stenting fails and in whom surgery is contraindicated or declined, insertion of a biliary self-expanding metal stent (SEMS) may be a valuable treatment option. Patients and Methods: Between 1994

  16. Trial of self-expandable metallic stents in the palliation of tracheo ...

    African Journals Online (AJOL)

    Trial of self-expandable metallic stents in the palliation of tracheo-oesophageal fistula in carcinoma of the oesophagus. ... Over half of the patients in the TOF group had concomitant pneumonia at presentation with decreased survival (p = 0.010) and a hazard ratio of 10.86. Two patients died, on days 4 and 7 respectively.

  17. Early recurrence of obstructive jaundice after placement of a self-expanding metal endoprosthesis

    NARCIS (Netherlands)

    Fockens, P.; Waxman, I.; Davids, P. H.; Huibregtse, K.; Tytgat, G. N.

    1992-01-01

    Self-expanding metal endoprostheses have ben used in the treatment of malignant obstructive jaundice for a few years. We report on a patient with obstructive jaundice due to a metastasis of a squamous cell lung cancer into the pancreatic head who received an expandable metal endoprosthesis and

  18. Results of the new nitinol self-expandable stents for distal biliary structures

    NARCIS (Netherlands)

    Smits, M.; Huibregtse, K.; Tytgat, G.

    1995-01-01

    The nitinol stent is a self-expandable spiral stent made of nickel-titanium alloy. We performed a pilot study to evaluate the method of stent insertion and stent efficacy. Twenty-eight patients with irresectable malignancy had nitinol stents inserted for obstructive jaundice due to distal biliary

  19. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  20. The treatment of complex airway diseases with inverted Y-shaped self-expandable metal stent

    International Nuclear Information System (INIS)

    Li Jianming; Jia Guangzhi

    2011-01-01

    Objective: To investigate the application and therapeutic effects of inverted Y-shaped self-expandable metal airway stent in treating complex airway diseases (stenosis or fistula). Methods: According to the distinctive anatomic structure and the pathological changes of complex airway stenosis or fistula, the inverted y-shaped self-expandable metal airway stent was designed. Under fluoroscopic monitoring, a total of 12 inverted Y-shaped self-expandable metal stents were implanted in 12 patients with complex airway diseases. Results: Stent placement in the trachea-bronchial tree was technically successful in all patients. After the operation, the symptom of dyspnea was immediately relieved and the bucking following food intake disappeared. The general physical condition and living quality were much improved in all patients. Conclusion: The use of inverted Y-shaped self-expandable metal airway stent for the management of complex airway stenosis involving the tracheal carina was a simple and safe procedure and it has satisfactory short-term clinical results. (authors)

  1. Percutaneous metallic self-expandable endoprostheses in malignant hilar biliary obstruction

    NARCIS (Netherlands)

    Stoker, J.; Laméris, J. S.; van Blankenstein, M.

    1993-01-01

    Forty-five patients with malignant hilar obstruction were treated with a total of 68 percutaneously inserted metallic self-expandable endoprostheses (Wallstents) for palliative biliary drainage. The stent diameter was 1 cm; the length was 3.5 to 10.5 cm. Early complications occurred in seven

  2. Self-expandable metal stent placement versus emergency resection for malignant proximal colon obstructions

    NARCIS (Netherlands)

    Amelung, F.J.; Draaisma, W.A.; Consten, E.C.; Siersema, P.D.; Borg, F. ter

    2017-01-01

    BACKGROUND: Traditionally, all patients with a malignant obstruction of the proximal colon (MOPC) are treated with emergency resection. However, recent data suggest that Self-expandable metallic stent (SEMS) placement could lower mortality and morbidity rates. This study therefore aimed to compare

  3. Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: Clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA

    NARCIS (Netherlands)

    Baan, J.; Yong, Z. Y.; Koch, K. T.; Henriques, J. P. S.; Bouma, B. J.; de Hert, S. G.; van der Meulen, J.; Tijssen, J. G. P.; Piek, J. J.; de Mol, B. A. J. M.

    2010-01-01

    Objective. To report the feasibility, safety and efficacy of percutaneous aortic valve implantation (PAVI) with the CoreValve self-expanding aortic valve bioprosthesis in elderly patients with aortic valve stenosis who are rejected for surgery or have a high surgical risk.Methods. PAVI using the

  4. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults.

    Science.gov (United States)

    Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam

    2017-09-01

    Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.

  5. Treatment of Pelvic Venous Spur (May-Thurner Syndrome) with Self-Expanding Metallic Endoprostheses

    International Nuclear Information System (INIS)

    Binkert, Christoph A.; Schoch, Eric; Stuckmann, Gerd; Largiader, Jon; Wigger, Pius; Schoepke, Wolfdietrich; Zollikofer, Christoph L.

    1998-01-01

    Purpose: The application of self-expanding metallic endoprostheses (stents) to treat symptomatic pelvic venous spurs as an alternative to surgery. Methods: Wallstents with a diameter from 14 to 16 mm and one Cragg stent were placed in the left common iliac vein of eight patients (seven women, one man; mean age 42 years) with a symptomatic pelvic venous spur (left deep venous thrombosis or post-thrombotic leg swelling). Four patients had surgical thrombectomy prior to stent placement. Results: Technical success with immediate reduction of left leg circumference was achieved in all eight patients. A primary patency rate of 100% was observed during an average follow-up of 3 years (range 10-121 months). There were no procedural or stent-related complications. Conclusion: The percutaneous transfemoral placement of self-expanding metallic stents is an effective minimally invasive alternative to surgery in the treatment of symptomatic pelvic venous spur

  6. Relative Lyapunov Center Bifurcations

    DEFF Research Database (Denmark)

    Wulff, Claudia; Schilder, Frank

    2014-01-01

    Relative equilibria (REs) and relative periodic orbits (RPOs) are ubiquitous in symmetric Hamiltonian systems and occur, for example, in celestial mechanics, molecular dynamics, and rigid body motion. REs are equilibria, and RPOs are periodic orbits of the symmetry reduced system. Relative Lyapunov...... center bifurcations are bifurcations of RPOs from REs corresponding to Lyapunov center bifurcations of the symmetry reduced dynamics. In this paper we first prove a relative Lyapunov center theorem by combining recent results on the persistence of RPOs in Hamiltonian systems with a symmetric Lyapunov...... center theorem of Montaldi, Roberts, and Stewart. We then develop numerical methods for the detection of relative Lyapunov center bifurcations along branches of RPOs and for their computation. We apply our methods to Lagrangian REs of the N-body problem....

  7. Effects of the Temporary Placement of a Self-Expandable Metallic Stent in Benign Pyloric Stenosis

    OpenAIRE

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-01-01

    Background/Aims The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Methods Twenty-two patients with benign sten...

  8. Removal of self expandable metallic airway stent: A rare case report

    OpenAIRE

    Chawla, Rakesh K.; Madan, Arun; Singh, Ishwar; Mudoiya, Rahul; Chawla, Aditya; Gupta, Radha; Chawla, Kiran; Chhabra, Roopam

    2013-01-01

    Covered self expandable metallic airway stents (SEMS) have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after p...

  9. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  10. The use of self expandable metallic stent in the management of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-05-15

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency.

  11. Use of covered self-expandable stents for benign colorectal disorders in children.

    Science.gov (United States)

    Lange, Bettina; Sold, Moritz; Kähler, Georg; Wessel, Lucas M; Kubiak, Rainer

    2017-01-01

    There is a lack of experience with covered self-expandable stents for benign colorectal disorders in children. Five children (4M, 1F) with a median age of 5years (range, 6months-9years) who underwent treatment with covered self-expandable plastic (SEPSs) or self-expandable metal stents (SEMSs) for a benign colorectal condition between April 2005 and November 2013 were recruited to this retrospective study. Etiologies included: anastomotic stricture with (n=1) or without (n=3) simultaneous enterocutaneous fistula, as well as an anastomotic leak associated with enterocutaneous fistula (n=1). All children suffered from either Hirschsprung's disease (n=3) or total colonic aganglionosis (Zuelzer-Wilson syndrome) (n=2). Median duration of individual stent placement was 23days (range, 1-87days). In all cases up to five different stents were placed over time. At follow-up two patients were successfully treated without further intervention. In another patient the anastomotic stricture resolved fully, but a coexisting enterocutaneous fistula persisted. Overall, three patients did not improve completely following stenting and required definite surgery. Stent-related problems were noted in all cases. There was one perforation of the colon at stent insertion. Further complications consisted of stent dislocation (n=4), obstruction (n=1), formation of granulation tissue (n=1), ulceration (n=1) and discomfort (n=3). Covered self-expandable stents enrich the armamentarium of interventions for benign colorectal disorders in children including anastomotic strictures and intestinal leaks. A stent can be applied either as an emergency procedure (bridge to surgery) or as an adjuvant treatment further to endoscopy and dilatation. Postinterventional problems are frequent but there is a potential for temporary or definite improvement following stent insertion. Copyright © 2017. Published by Elsevier Inc.

  12. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    Science.gov (United States)

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p stent use for palliation (78.6% vs 56.3%; p stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http

  13. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  14. The use of self expandable metallic stent in the management of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung

    1993-01-01

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency

  15. Treatment of Benign Tracheal Stenosis Utilizing Self-Expanding Nitinol Stents

    International Nuclear Information System (INIS)

    Sesterhenn, Andreas M.; Wagner, Hans-Joachim; Alfke, Heiko; Werner, Jochen A.; Lippert, Burkard M.

    2004-01-01

    We assessed the results of self-expanding metallic stent insertion into benign proximal tracheal stenosis in patients not appropriate or unfit for surgical repair. Proximal benign tracheal stenoses had occurred in 11 patients (7 men, 4 women, mean age 68.8 years) after long-time intubation (n = 6), tracheostomy (n = 4), or chondropathia (n = 1). Fourteen self-expanding nitinol stents were placed in the patients under general anesthesia with endoscopical and fluoroscopical guidance. Stent insertion was successful in all cases and led to immediate relief of the morphological and functional airway obstruction. No immediate complications were noted. During the mean follow-up period of 67.5 weeks we observed one recurrent dyspnea 3 months after implantation and granuloma formation at the stent insertion site in another patient. Both complications were successfully treated with additional stent insertion in one case and laser resection of granulomas in the other. Self-expanding nitinol stents should be considered for the treatment of benign proximal tracheal obstruction in selected patients for whom surgical repair is contraindicated

  16. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-06-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  17. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    International Nuclear Information System (INIS)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-01-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  18. Treatment of tracheobronchial stenosis with a self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeon, Seok Chol; Choi, Chul Seung; Choi, Yo Won; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1994-07-15

    We analysed the role of modified Gianturco self-expandable stents in the treatment of tracheobronchial stenosis in 13 patients. We inserted modified Gianturco self-expandable stents under the fluoroscopic and bronchoscopic guidance. There were stenosis in the trachea(n=2), the right main bronchus(n=2), and the left main bronchus(n=9). The causes of the stenosis were endobronchial tuberculosis(n=10), intubation granuloma(n=1), restenosis after surgical reconstruction(n=2). Dyspnea or wheezing was improved within 1 or 2 days following the procedure. There were 32% and 22% respective increase in average FEV1 and FVC. Lung perfusion scan showed 9.6% increase of perfusion in the involved lung. No complications related to the procedure were encountered. During follow-up period of up to 31 months, 2 patients showed tracheal or bronchial restenosis, at 3 and 6 months, retrospectively. There was a distal migration of the stents in one case. During the follow up period after stent insertion, improvement of the obstructive changes and dyspnea persisted in 10 out of 13 patients. The modified Gianturco self-expandable metallic stents may be a good choice for the treatment of tracheobronchial stenosis, either as a primary treatment, or when the reconstruction failed.

  19. Feasibility of using bulk metallic glass for self-expandable stent applications.

    Science.gov (United States)

    Praveen Kumar, Gideon; Jafary-Zadeh, Mehdi; Tavakoli, Rouhollah; Cui, Fangsen

    2017-10-01

    Self-expandable stents are widely used to restore blood flow in a diseased artery segment by keeping the artery open after angioplasty. Despite the prevalent use of conventional crystalline metallic alloys, for example, nitinol, to construct self-expandable stents, new biomaterials such as bulk metallic glasses (BMGs) are being actively pursued to improve stent performance. Here, we conducted a series of analyses including finite element analysis and molecular dynamics simulations to investigate the feasibility of using a prototypical Zr-based BMG for self-expandable stent applications. We model stent crimping of several designs for different percutaneous applications. Our results indicate that BMG-based stents with diamond-shaped crowns suffer from severe localization of plastic deformation and abrupt failure during crimping. As a possible solution, we further illustrate that such abrupt failure could be avoided in BMG-based stents without diamond shape crowns. This work would open a new horizon for a quest toward exploiting superior mechanical and functional properties of metallic glasses to design future stents. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1874-1882, 2017. © 2016 Wiley Periodicals, Inc.

  20. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  1. Development of a New Intravascular Low-Profile Device for Exclusion of Aortic Aneurysm: An Experimental Pilot Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Haberstroh, Joerg; Boos, Irene; Metz, Stephan; Langer, Mathias; Moliner, Manuel Maynar

    2004-01-01

    Purpose: To present a new intravascular device for the treatment of aorto-iliac aneurysms. Methods: This new device was tested in five dogs with abdominal aortic aneurysm created experimentally by overdilation of a balloon-expandable stent with a 16 or 18 mm wide PTA balloon catheter. The design of the device is based on a self-expanding aortic stent which consists of two stretchable circular frames filled with a textile Dacron mesh membrane that is suspended horizontally into the infrarenal abdominal aorta proximally to the aneurysm. The frames are part of a preshaped double helical structure that is introduced longitudinally through a catheter in a parallel fashion and forming the desired shape at the vessel site to be occluded. Two iliac stent-grafts are introduced in a low-profile status through the membrane sealing the aneurysm sac and holding the stent-grafts in place. After stent-graft expansion, a new bifurcation located more proximally than the natural one is created. The follow-up of the dogs was performed clinically and angiographically, and specimens were evaluated histomorphologically. Results: The membrane device can be introduced through a 9 Fr vascular sheath. Technical success was achieved in four of five dogs. Nine of ten stent-grafts could be fixed securely within the membrane, thus preventing dislocation. Aneurysms were excluded immediately, and blood flow to the external iliac arteries was restored by the stent-grafts. At 6-9 months follow-up of technically successful implanted devices, there were no endoleaks, no migration, no stenoses at contact sites between the implant material and vascular wall, and no stenosis or occlusion of the stent-grafts. At microscopic evaluation, the interspace between the membranes was filled with thrombotic material, thus ensuring exclusion of the aneurysm. Conclusion: This new device was found to be flexible, low profile and useful in excluding abdominal aortic aneurysm in the experimental setting

  2. Aortic insufficiency

    Science.gov (United States)

    ... page, please enable JavaScript. Aortic insufficiency is a heart valve disease in which the aortic valve does not close ... aortic insufficiency Images Aortic insufficiency References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  3. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    Science.gov (United States)

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  4. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2011-01-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery.......The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery....

  5. Surgery for acute Type I aortic dissection without resection of supra-aortic entry sites leads to unfavourable aortic remodelling.

    Science.gov (United States)

    Heo, Woon; Song, Suk-Won; Lee, Kwang-Hun; Lee, Shin-Young; Kim, Tae-Hoon; Baek, Min-Young; Yoo, Kyung-Jong

    2018-01-29

    This study aimed to evaluate the impact of remnant re-entries in arch branches on postoperative change in the aortic arch and descending aortic diameters and the rate of major adverse aortic events. Between January 2010 and December 2016, 249 patients underwent surgery for acute Type I aortic dissection. Patients who underwent total arch replacement, had Marfan syndrome or had intramural haematoma were excluded. Seventy-two patients with predischarge and follow-up computed tomography scans were enrolled. Patients with and without re-entries in the arch branches after surgery were assigned to the supra-aortic entry (SAE, n = 21) and no supra-aortic entry (n = 51) groups, respectively. Diameters were measured at 7 levels: the innominate artery, left common carotid artery, left subclavian artery, 20 mm distal to the left subclavian artery, pulmonary artery bifurcation, coeliac axis and maximal diameter of the descending thoracic aorta. Growth rates at the levels of the pulmonary artery bifurcation and 20 mm distal to the left subclavian artery were significantly higher in the SAE group than in the no supra-aortic entry group. The rate of freedom from major adverse aortic events (annual growth >5 mm or maximal diameter of the descending thoracic aorta >50 mm) at 5 years was significantly higher in the no supra-aortic entry group than in the SAE group. Remnant SAE leads to unfavourable aortic remodelling after acute Type I aortic dissection repair. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. The technique study and primary clinical application of inverted Y-shaped self-expandable metal airway stent

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Ma Ji; Yang Ruimin; Guan Sheng; Ma Nan; Wang Yanli

    2007-01-01

    Objective: To investigate the feasibility and primary therapeutic effect of inverted Y-shaped self-expandable metal stent for complex airway stenosis. Methods: On the standpoint of the peculiar anatomic structure and the pathological changes of complex airway stenosis, we designed the inverted Y-shaped self-expandable metal stent. Under the fluoroscopic guidance, 7 stents were implanted in 7 cases of airway complex stenosis. Results: The inverted Y-shaped self-expandable metal stents were placed seccussfully, with instantaneous relief of dyspnea and improvement of living quality. Conclusion: The placement of inverted Y-shaped self-expandable metal stent is feasible and safe for treating airway complex stenosis. (authors)

  7. Endoscopic palliation of patients with biliary obstruction caused by nonresectable hilar cholangiocarcinoma: efficacy of self-expandable metallic Wallstents

    NARCIS (Netherlands)

    Cheng, John L. S.; Bruno, Marco J.; Bergman, Jacques J.; Rauws, Erik A.; Tytgat, Guido N.; Huibregtse, Kees

    2002-01-01

    Background: The aim of this study was to evaluate the efficacy of an endoscopically inserted self-expandable metal stent for treatment of biliary obstruction caused by nonresectable hilar cholangiocarcinoma. Methods: Data on all patients with nonresectable hilar cholangiocarcinoma receiving

  8. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F. [Dept. of Radiology, South Manchester University Hospitals NHS Trust, Withington Hospital (United Kingdom)

    1999-07-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  9. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    Science.gov (United States)

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  11. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    International Nuclear Information System (INIS)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F.

    1999-01-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  12. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  13. Bifurcations of transition states: Morse bifurcations

    International Nuclear Information System (INIS)

    MacKay, R S; Strub, D C

    2014-01-01

    A transition state for a Hamiltonian system is a closed, invariant, oriented, codimension-2 submanifold of an energy level that can be spanned by two compact codimension-1 surfaces of unidirectional flux whose union, called a dividing surface, locally separates the energy level into two components and has no local recrossings. For this to happen robustly to all smooth perturbations, the transition state must be normally hyperbolic. The dividing surface then has locally minimal geometric flux through it, giving an upper bound on the rate of transport in either direction. Transition states diffeomorphic to S 2m−3 are known to exist for energies just above any index-1 critical point of a Hamiltonian of m degrees of freedom, with dividing surfaces S 2m−2 . The question addressed here is what qualitative changes in the transition state, and consequently the dividing surface, may occur as the energy or other parameters are varied? We find that there is a class of systems for which the transition state becomes singular and then regains normal hyperbolicity with a change in diffeomorphism class. These are Morse bifurcations. Various examples are considered. Firstly, some simple examples in which transition states connect or disconnect, and the dividing surface may become a torus or other. Then, we show how sequences of Morse bifurcations producing various interesting forms of transition state and dividing surface are present in reacting systems, by considering a hypothetical class of bimolecular reactions in gas phase. (paper)

  14. Bifurcation with memory

    International Nuclear Information System (INIS)

    Olmstead, W.E.; Davis, S.H.; Rosenblat, S.; Kath, W.L.

    1986-01-01

    A model equation containing a memory integral is posed. The extent of the memory, the relaxation time lambda, controls the bifurcation behavior as the control parameter R is increased. Small (large) lambda gives steady (periodic) bifurcation. There is a double eigenvalue at lambda = lambda 1 , separating purely steady (lambda 1 ) from combined steady/T-periodic (lambda > lambda 1 ) states with T → infinity as lambda → lambda + 1 . Analysis leads to the co-existence of stable steady/periodic states and as R is increased, the periodic states give way to the steady states. Numerical solutions show that this behavior persists away from lambda = lambda 1

  15. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  16. Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.

    Science.gov (United States)

    Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko

    2016-12-01

    Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.

  17. Malignant inferior vena cava obstruction involving right atrium. Palliative treatment with self expandable metallic stent

    International Nuclear Information System (INIS)

    Shao Guoliang; Wang Jianhua; Zhou Kangrong; Yan Zhiping

    2001-01-01

    Objective: To investigate the safety and efficacy of placement of self-expandable metallic stent within right atrium and inferior vena cava (ICV) in patients with malignant ICV obstruction involving right atrium. Methods: There were 5 male patients with advanced hepatocellular carcinoma, aged from 42 to 65 years (mean 56.3 years). The malignancies invaded right atrium and ICV simultaneously, and caused obstruction of ICV. These patients presented symptoms and signs of obstruction of ICV such as hepatomegaly, ascites, edema of lower extremities. 'Z' type stainless steel stents (7.5-10.0 cm in length and 2.5 cm in diameter) were selected for these patients. Part (1.0-3.0 cm in length) of stent was placed in right atrium and the rest was in ICV. Results: All of stents were placed successfully and obstructed ICV reopened. The symptoms of obstruction of ICV relieved or disappeared. There were no recurrence of symptoms of obstruction of ICV and any cardiac complication related to placement of stents in follow-up period (67-188 days). Conclusion: Placement of self-expandable metallic stent within right atrium and ICV in treatment of patients with malignant ICV obstruction involving right atrium is one of the safe and effective methods

  18. Self-expanding stent-assisted middle cerebral artery recanalization: technical note

    International Nuclear Information System (INIS)

    Sauvageau, Eric; Levy, Elad I.

    2006-01-01

    Investigation into pharmacological and mechanical means of improving recanalization rates by intraarterial therapy has led to technological development. Angiographic recanalization has been associated with improvement in clinical outcome. A clot retriever has recently joined an imperfect armamentarium for intraarterial stroke therapy. In this report, we describe successful recanalization of an acute thrombotic occlusion of the inferior division of the middle cerebral artery (MCA) achieved with a self-expanding stent. An 82-year-old woman with a history of coronary atherosclerosis and previous cerebellar hemorrhage presented with a National Institutes of Health Stroke Scale (NIHSS) score of 11. Perfusion computed tomography imaging showed a left MCA territory deficit. Diffusion-weighted magnetic resonance (MR) imaging revealed a small punctiform insular hyperintensity. Angiography documented occlusion of the inferior division of the left MCA (Thrombolysis in Myocardial Infarction or Thrombolysis in Cerebral Infarction, TIMI/TICI, grade 0). Intraarterial delivery of eptifibatide to the occlusion site failed to recanalize the vessel. Deployment of a self-expanding stent in the occluded segment resulted in complete revascularization of the distal vascular bed. Angiography performed on the next day confirmed patency of the stented vessel segment (TIMI/TICI 3). The patient was discharged 3 days after the procedure (NIHSS 3). MR angiography obtained 3 months after the procedure documented left MCA patency. This technique may have a role worthy of further investigation in acute stroke therapy. (orig.)

  19. Insertion of self-expanding metal stent for treatment of malignant obstruction in a pregnant woman

    Directory of Open Access Journals (Sweden)

    Noelia Alonso-Lázaro

    2014-03-01

    Full Text Available Colorectal cancer (CRC is the second most frequent cancer both in incidence and mortality in women, especially in those over 60 years of age. Diagnosis in women at gestational age is rare, so its incidence during pregnancy is low. However, an increase in its diagnosis is expected during the next years because of the raise in the average age of pregnancy. In most cases, the diagnosis is delayed because symptoms related to CRC can be attributed to pregnancy itself. Up to 30 % of CRC cases may present as an intestinal obstruction. In this situation, the main objective is to solve the clinical emergency in the safest way for mother and fetus, together with performing an accurate diagnostic approach to offer the best possible therapeutic management knowing the limitations and difficulties related to pregnancy. The self-expanding metallic stent (SEMS can be particularly useful in colon obstruction in a pregnant patient with CRC because it allows solving the acute condition providing time to perform a more accurate staging study and to prepare the patient for surgery, thus reducing both post-surgical morbidity and mortality. We report on the case of a patient who early in the second trimester of pregnancy presented with an acute colonic obstruction due to CRC which was successfully managed with the placement of a self-expanding metal stent.

  20. Self-Expanding Metal Stents Improve Swallowing and Maintain Nutrition During Neoadjuvant Therapy for Esophageal Cancer.

    Science.gov (United States)

    Smith, Zachary L; Gonzaga, Jason E; Haasler, George B; Gore, Elizabeth M; Dua, Kulwinder S

    2017-06-01

    Patients with locally advanced esophageal cancer can have significant dysphagia. Nutritional support during neoadjuvant therapy is often delivered via nasoenteric or percutaneous feeding tubes. These approaches do not allow for per-oral feeding. Evaluate the safety and efficacy of fully covered self-expanding metal esophageal stents for nutritional support during neoadjuvant therapy. This was a pilot, prospective study at a single tertiary center. From March 2012 to May 2013, consecutive patients with esophageal cancer eligible for neoadjuvant therapy were enrolled. Metal stents were placed prior to starting neoadjuvant therapy. Data were collected at baseline and predetermined intervals until an endpoint (surgery or disease progression). Outcomes included dysphagia grade, satisfaction of swallowing score, nutritional status (weight, serum albumin), impact on surgery, and adverse events. Fourteen stents were placed in 12 patients (59.1 ± 9.5 years, 11 men, 1 woman). Dysphagia grade (pre 3.4 ± 0.5 vs post 0.2 ± 0.4, p esophageal cancer, self-expanding metal stents are safe and effective in relieving dysphagia and maintaining nutrition. They allow patients to eat orally, thereby improving patient satisfaction. The presence of an in situ stent did not interfere with surgery.

  1. Comparison of Self-Expanding Polyethylene Terephthalate and Metallic Stents Implanted in Porcine Iliac Arteries

    International Nuclear Information System (INIS)

    Wilczek, Krzysztof; Scheerder, Ivan de; Wang Kai; Verbeken, Eric; Piessens, Jan

    1996-01-01

    Purpose: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). Methods: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. Results: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). Conclusion: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents

  2. Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

    Science.gov (United States)

    Song, Ho-Young; Kim, Choung Soo; Jeong, In Gab; Yoo, Dalsan; Kim, Jin Hyoung; Nam, Deok Ho; Bae, Jae-Ik; Park, Jung-Hoon

    2013-03-01

    To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer. Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications. Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal. These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.

  3. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  4. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  5. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  6. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  7. Polyurethane-Covered Self-expandable Nitinol Stent for Malignant Biliary Obstruction: Preliminary Results

    International Nuclear Information System (INIS)

    Han, Young-Min; Hwang, Seung-Bae; Lee, Soo-Teik; Lee, Jeong-Min; Chung, Gyung-Ho

    2002-01-01

    Purpose: To evaluate the immediate and long-term results in ten patients with malignant biliary obstruction using a polyurethane-covered, self-expandable nitinol stent.Methods: A nitinol stent, fully covered with high-elasticity polyurethane, with an unconstrained diameter of 10 mm and a total length of 60-80 mm, was placed transhepatically under fluoroscopic guidance in ten patients. The length of the biliary obstruction varied between 30-50 mm. The follow-up examination included a clinical assessment, serum bilirubin measurement, and ultrasound examinations at one-month intervals in all patients. Results: Initial stent deployment was successful in eight patients. Two patients experienced proximal migration,which was solved by insertion of two, uncovered Wallstents. One patient had the stent removed after two weeks because of severe nausea and vomiting. One patient had delayed migration of the covered stent after 40 weeks. The follow-up duration was 3-40 weeks (Mean: 16.9 weeks). Seven patients died(3-26 weeks) and three patients survived (24-40 weeks). The bilirubin measurements in all patients had significantly decreased one week after stent insertion. The levels of amylase and lipase had did not increase after stent insertion. Conclusions: Apolyurethane-covered, self-expandable nitinol stent can be used effectively and safely in the treatment of malignant biliary obstruction. The preliminary results are favorable, but there is a need for further large studies to determine both long-term survival and patency

  8. Use of nitinol self-expandable stents in 26 dogs with tracheal collapse.

    Science.gov (United States)

    Beranek, J; Jaresova, H; Rytz, U

    2014-02-01

    A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

  9. Long-term results of percutaneous self-expandable metallic stents in malignant biliary obstruction

    International Nuclear Information System (INIS)

    Kobashi, Yuko; Hoshikawa, Yoshikazu

    2004-01-01

    Evaluation of the long-term follow-up data of 155 patients with inoperable malignant biliary obstruction who received percutaneous placement of self expandable metallic stent (EMS) and external beam radiotherapy (EBR) combined with self-expandable metallic stent. One-hundred sixty EMS were inserted in 155 patients with inoperable malignant biliary obstruction. One-hundred forty-three patients (Group A) were inserted EMS alone. Twelve patients (Group B) underwent external radiotherapy (40∼45 Gy) after stent insertion. We compared to the Group A and Group B about survival, stent patency and administration. The mean length of survival for the entire group was 111±87 days, while the mean period of patency for all stents was 103±74. We found no statistically significant difference in patient survival or stent patency periods in regard to the level and cause of obstruction. Prolongation of actuarial survival was observed in Group B (316±231 days) as compared to Group A (126±85 days,). Mean length of survival rate and mean period of stent patency rate were not significantly different in regard to the level, cause of obstruction and each stent. External radiotherapy combined EMS could achieve effective palliation and improve the quality of life in selected patients with malignant biliary obstruction. (author)

  10. Energetics and monsoon bifurcations

    Science.gov (United States)

    Seshadri, Ashwin K.

    2017-01-01

    Monsoons involve increases in dry static energy (DSE), with primary contributions from increased shortwave radiation and condensation of water vapor, compensated by DSE export via horizontal fluxes in monsoonal circulations. We introduce a simple box-model characterizing evolution of the DSE budget to study nonlinear dynamics of steady-state monsoons. Horizontal fluxes of DSE are stabilizing during monsoons, exporting DSE and hence weakening the monsoonal circulation. By contrast latent heat addition (LHA) due to condensation of water vapor destabilizes, by increasing the DSE budget. These two factors, horizontal DSE fluxes and LHA, are most strongly dependent on the contrast in tropospheric mean temperature between land and ocean. For the steady-state DSE in the box-model to be stable, the DSE flux should depend more strongly on the temperature contrast than LHA; stronger circulation then reduces DSE and thereby restores equilibrium. We present conditions for this to occur. The main focus of the paper is describing conditions for bifurcation behavior of simple models. Previous authors presented a minimal model of abrupt monsoon transitions and argued that such behavior can be related to a positive feedback called the `moisture advection feedback'. However, by accounting for the effect of vertical lapse rate of temperature on the DSE flux, we show that bifurcations are not a generic property of such models despite these fluxes being nonlinear in the temperature contrast. We explain the origin of this behavior and describe conditions for a bifurcation to occur. This is illustrated for the case of the July-mean monsoon over India. The default model with mean parameter estimates does not contain a bifurcation, but the model admits bifurcation as parameters are varied.

  11. Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis.

    Science.gov (United States)

    Buellesfeld, Lutz; Gerckens, Ulrich; Grube, Eberhard

    2008-04-01

    Percutaneous aortic valve replacement is a new less-invasive alternative for high-risk surgical candidates with aortic stenosis. However, the clinical experience is still limited, and the currently available 'first-generation devices' revealed technical shortcomings, such as lack of repositionability and presence of paravalvular leakages. We report the first-in-man experience with the new self-expanding Lotus Valve prosthesis composed of a nitinol frame with implemented bovine pericardial leaflets which is designed to address these issues, being repositionable and covered by a flexible membrane to seal paravalvular gaps. We implanted this prosthesis in a 93-year old patient presenting with severe symptomatic aortic stenosis (valve area: 0.6 cm(2)). Surgical valve replacement had been declined due to comorbidities. We used a retrograde approach for insertion of the 21-French Lotus catheter loaded with the valve prosthesis via surgical cut-down to the external iliac artery. Positioning of the valve was guided by transesophageal echo and supra-aortic angiograms. The prosthesis was successfully inserted and deployed within the calcified native valve. Echocardiography immediately after device deployment showed a significant reduction of the transaortic mean pressure gradient (32 to 9 mmHg; final valve area 1.7 cm(2)) without evidence of residual aortic regurgitation. The postprocedural clinical status improved from NYHA-IV to NYHA-II. These results remained unchanged up to the 3 month follow-up. Successful percutaneous aortic valve replacement can be performed using the new self-expanding and repositionable Lotus valve for treatment of high-risk patients with aortic valve stenosis. Further studies are mandatory to assess device safety and efficacy in larger patient populations. Copyright 2008 Wiley-Liss, Inc.

  12. Comparison of visibility for four self-expanding nitinol bare stents in vitro

    International Nuclear Information System (INIS)

    Wiesinger, Benjamin; Stutz, Alexander; Schmehl, Joerg; Groezinger, Gerd; Claussen, Claus Detlef; Wiskirchen, Jakub

    2012-01-01

    Background Sufficient radiopacity of stents is a prerequisite for safe interventions and minimization of the radiation dose for the patient and the interventionist. Modern nitinol stents are considered less radiopaque compared to formerly used stents. Purpose To evaluate the objective detection rate (ODR) and the subjective radiopacity score (SRS) of four self-expanding nitinol stents with their markers on a phantom human pelvis. Material and Methods We evaluated the ODR (as a percentage of correctly identified stents) and the SRS (on a scale from 0 = not visible to 4 = excellent visibility) for four self-expanding nitinol stents (SinusSuperflex, SMART, Luminexx, Zilver) with 8 mm diameter and 40 mm length. Stents were placed on a phantom human pelvis and images of the stents were taken in four different positions (right and left lumbosacral joint and near the right and left limbus acetabuli) using the following modes: spotfilm, pulsed fluoroscopy (4, 7.5, 15, and 30 pulses/min) and at three different digital magnification modes. Dose area products (DAPs) were assessed. Results ODR and SRS, respectively, were significantly increased for the SMART stent compared to all other tested stents (P < 0.05): SMART 93.53% and 2.43, SinusSuperflex 90.81% and 2.21, Luminexx 90.39% and 2.20, and Zilver 89.28% and 2.21. ODR was significantly reduced in position 3 where the bone overlap was more pronounced for all stents (detection rates 77.14-79.56%). An increase in magnification significantly improved the ODR and SRS for all stents (70.33-99.25% and 1.07-3.28, respectively, P < 0.05). Increased pulsing frequency did not improve the ODR of the various stents but did increase the DAP. Conclusion The SMART stent had the best overall performance. In the presence of bone overlap, all self-expanding nitinol stents had poor results. Increased pulsing frequency did not improve ODR or SRS but did increase the DAP. Use of digital magnification modes had no effect on DAP increasing ODR

  13. Clinical Application of Fully Covered Self-Expandable Metal Stents in the Treatment of Bronchial Fistula.

    Science.gov (United States)

    Cao, Ming; Zhu, Qiang; Wang, Wei; Zhang, Tian Xiao; Jiang, Min Zhong; Zang, Qi

    2016-09-01

    Background The study was designed to access the feasibility, safety, and efficacy of fully covered self-expandable metal stents in the treatment of bronchial fistula. Methods Clinical data of nine patients (seven males and two females) who were treated with placement of tracheobronchial or bronchial fully covered self-expandable metal stents from August 2005 to November 2011 were analyzed retrospectively. Among these patients, seven were diagnosed with bronchopleural fistula, one with tracheopleural fistula, and one with left main bronchoesophageal fistula. Eight had accompanying thoracic empyema. The fistula orifices ranged from 3.5 mm to 25 mm in diameter. All patients received topical anesthesia. L-shaped stents were placed in six patients and I-shaped stents in three under fluoroscopic guidance. After stent placement, patients with empyema were treated with pleural lavage. Results Stent placement in the tracheobronchial tree was successful in all patients, without procedure-related complications. The operating time was 5 to 16 minutes. A small amount of bubble overflowed from the intrathoracic drainage tube of only one patient. In the other patients, the bubble in the intrathoracic drainage tube disappeared immediately or angiography showed no overflow of contrast agent from the fistula orifice. The effective rate of fistula orifice closure after stent placement was 100%, with 88.9% rated as excellent. One patient coughed the stent out 5 days after placement and hence a new stent was placed. Among the patients with empyema, one died of septicemia arising from empyema on day 8 and another died of brain metastases of lung cancer 6 months after stent insertion with persistent empyema. In the other six patients, empyema resolved after 2 to 5 months (cure rate 75%). Seven patients were followed up for 3 to 36 months. During follow-up, one stent was removed 8 months after implantation due to difficult expectoration, without recurrent empyema. The remaining

  14. [Clinical application of a fully covered self-expandable metallic stent in treatment of airway fistula].

    Science.gov (United States)

    Zhu, Qiang; Zang, Qi; Jiang, Zhong-min; Wang, Wei; Cao, Ming

    2013-06-01

    To assess the feasibility, safety and efficacy of the use of a fully covered self-expandable stent for the treatment of airway fistula. From August 2005 to November 2011, 9 patients underwent treatment by the introduction of a tracheo-bronchial or bronchial fully covered self-expandable metallic stent. There were 7 males and 2 females, aged from 28-65 years with a mean of 46 years. In this group, 7 cases were diagnosed as bronchopleural fistula, 1 case as tracheopleural fistula, 1 case as broncho-esophageal fistula, 8 cases with thoracic empyema. The fistula orifices were from 3.5-25.0 mm in diameter with a mean 8.4 mm. All patients received topical anesthesia, and L-shaped stent was placed in 6 patients and I-shaped stent in 3 patients under fluoroscopic guidance. After the stent placement, the patients with empyema were treated with continual irrigation of the empyema cavity. Stent placement in the tracheo-bronchial tree was technically successful in all patients, without procedure-related complications. The operating time was from 5-16 minutes, mean time (10 ± 4) minutes. Except for 1 patient, immediate closure of the airway fistula was achieved in the other patients after the procedure, as shown by the immediate cessation of bubbling in the chest drain system or the contrast examination. In this study, 1 patient coughed the inserted stent out due to irritable cough on the 5th day and had to receive repositioning of a new stent. Among the patients who were with empyema, 1 patient died of septicemia on the 8th day and 1 patient died of brain metastases from lung cancer 6 months after the stent insertion with empyema not cured, the other 6 patients' empyema healed from 2-5 months, mean time 3.7 months. Seven patients were followed from 3 to 36 months with a median of 13.5 months. During follow-up, 1 stent was removed from a patient 8 months after the stent implantation without empyema recurred. The remaining patient presented good tolerability to the existence of

  15. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    Science.gov (United States)

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  16. Dedicated bifurcation stents

    Directory of Open Access Journals (Sweden)

    Ajith Ananthakrishna Pillai

    2012-03-01

    Full Text Available Bifurcation percutaneous coronary intervention (PCI is still a difficult call for the interventionist despite advancements in the instrumentation, technical skill and the imaging modalities. With major cardiac events relate to the side-branch (SB compromise, the concept and practice of dedicated bifurcation stents seems exciting. Several designs of such dedicated stents are currently undergoing trials. This novel concept and pristine technology offers new hope notwithstanding the fact that we need to go a long way in widespread acceptance and practice of these gadgets. Some of these designs even though looks enterprising, the mere complex delivering technique and the demanding knowledge of the exact coronary anatomy makes their routine use challenging.

  17. Bifurcation and Nonlinear Oscillations.

    Science.gov (United States)

    1980-09-28

    Structural stability and bifurcation theory. pp. 549-560 in Dinamical Systems (Ed. MI. Peixoto), Academic Press, 1973. [211 J. Sotomayor, Generic one...Dynamical Systems Brown University ELECTP" 71, Providence, R. I. 02912 1EC 2 4 1980j //C -*)’ Septabe-4., 1980 / -A + This research was supported in...problems are discussed. The first one deals with the characterization of the flow for a periodic planar system which is the perturbation of an autonomous

  18. Numerical analysis of bifurcations

    International Nuclear Information System (INIS)

    Guckenheimer, J.

    1996-01-01

    This paper is a brief survey of numerical methods for computing bifurcations of generic families of dynamical systems. Emphasis is placed upon algorithms that reflect the structure of the underlying mathematical theory while retaining numerical efficiency. Significant improvements in the computational analysis of dynamical systems are to be expected from more reliance of geometric insight coming from dynamical systems theory. copyright 1996 American Institute of Physics

  19. Use of retrievable self-expanding stent in treating childhood benign oesophageal stricture

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhu Ming

    2007-01-01

    Objective: To evaluate the methods and effect of retrievable self-expanding esophageal stent in treating benign esophageal stenosis of children. Methods: The covered retrievable expandable nitinol stents were placed in 10 children with corrosive esophageal stenosis and post-anastomotic stenosis, age ranged from 2 to 12 years, the dysphagia scores were 3, Barium esophagography was taken before the use of retrievable stent. Results: The stents were placed safely in all patients without complications and were successfully removed after all. After the stent placement, all patients could take solid food without dysphagia. During 6 to 12 months follow-up after the stent removal, all children could eat satisfactorily with the dysphagia score as 0. Conclusion: The use of covered retrievable expandable stent is effective and safe in treating childhood benign esophageal stenosis. (authors)

  20. Role of Self-Expandable Metal Stents in Acute Variceal Bleeding

    Directory of Open Access Journals (Sweden)

    Fuad Maufa

    2012-01-01

    Full Text Available Acute variceal bleeding continues to be associated with significant mortality. Current standard of care combines hemodynamic stabilization, antibiotic prophylaxis, pharmacological agents, and endoscopic treatment. Rescue therapies using balloon tamponade or transjugular intrahepatic portosystemic shunt are implemented when first-line therapy fails. Rescue therapies have many limitations and are contraindicated in some cases. Placement of fully covered self-expandable metallic stent is a promising therapeutic technique that can be used to control bleeding in cases of refractory esophageal bleeding as an alternative to balloon tamponade. These stents can be left in place for as long as two weeks, allowing for improvement in liver function and institution of a more definitive treatment.

  1. cancerous esophagotracheal fistula: treatment of placement with covered self-expanding metallic stent

    International Nuclear Information System (INIS)

    Han Xinwei; Li Tianxiao; Wang Ruilin; Fan Qingxia

    1997-01-01

    Purpose: To treat the esophagotracheal fistula that was the main cause of death in patients with esophageal carcinoma, the placement of the stent was studied. Materials and methods: Under the fluoroscopic guidance, 28 stents (5 stents made in USA and 23 in China) were successfully implanted in all the 28 patients with esophagotracheal fistula. Results: The aphagia of the patients was greatly improved and a normal diet could be swallowed at once after the placement of the stents. The 27 cases of inhalation pneumonia that caused by the fistula was recovered. Conclusion: The result indicated that the treatment with the placement of the covered self-expanding stent is simple, safe, and effective for most patients with aphagia and pneumonia due to esophagotracheal fistula

  2. Short-term results of self-expanding metal stents for acute malignant large bowel obstruction

    DEFF Research Database (Denmark)

    Kobborg, M; Broholm, M; Frostberg, E

    2017-01-01

    AIM: Self-expanding metal stents (SEMSs) can be used as a palliative treatment or to initially decompress colon prior to definitive surgery (as a so-called 'bridge to surgery'). The purpose of this study was to investigate the efficacy and safety of SEMS used as palliation and bridge to surgery...... for malignant large bowel obstruction. METHOD: A multicentre retrospective study was conducted from January 2010 to December 2013 to identify patients undergoing stent placement for acute large bowel obstruction. Patients were included from four Danish colorectal centres. Outcomes identified included clinical...... success, 30-day mortality, stent related complications and surgery related complications. Furthermore, we analysed for predictive factors for successful stenting. Clinical success was defined as relief of obstructive symptoms, without the need of other additional surgical interventions during the hospital...

  3. Management of post-gastrectomy anastomosis site obstruction with a self-expandable metallic stent.

    Science.gov (United States)

    Cha, Ra Ri; Lee, Sang Soo; Kim, Hyunjin; Kim, Hong Jun; Kim, Tae-Hyo; Jung, Woon Tae; Lee, Ok Jae; Bae, Kyung Soo; Jeong, Sang-Ho; Ha, Chang Yoon

    2015-04-28

    Post-gastrectomy anastomosis site obstruction is a relatively rare complication after a subtotal gastrectomy. We present a case of a 75-year-old man who underwent a truncal vagotomy, omental patch, gastrojejunostomy, and Braun anastomosis for duodenal ulcer perforation and a gastric outlet obstruction. Following the 10(th) postoperative day, the patient complained of abdominal discomfort and vomiting. We diagnosed post-gastrectomy anastomosis site obstruction by an upper gastrointestinal series and an upper endoscopic examination. We inserted a self-expandable metallic stent (SEMS) at the anastomosis site. The stent was fully expanded after deployment. On the day following the stent insertion, the patient began to eat, and his abdominal discomfort was resolved. This paper describes the successful management of post-gastrectomy anastomosis site obstruction with temporary placement of a SEMS.

  4. Self-expandable metal stents for obstructing colonic and extracolonic cancer

    DEFF Research Database (Denmark)

    van Hooft, Jeanin E; van Halsema, Emo E; Vanbiervliet, Geoffroy

    2014-01-01

    as a bridge to elective surgery is not recommended as a standard treatment of symptomatic left-sided malignant colonic obstruction (strong recommendation, high quality evidence). 3 For patients with potentially curable but obstructing left-sided colonic cancer, stent placement may be considered......, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations The following recommendations should only be applied after a thorough diagnostic evaluation including a contrast-enhanced computed tomography (CT) scan. 1 Prophylactic colonic...... stent placement is not recommended. Colonic stenting should be reserved for patients with clinical symptoms and imaging evidence of malignant large-bowel obstruction, without signs of perforation (strong recommendation, low quality evidence). 2 Colonic self-expandable metal stent (SEMS) placement...

  5. Evaluation of the 4-French Pulsar-18 Self-expanding Nitinol Stent in Long Femoropopliteal Lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Hailer, Birgit; Kaeunicke, Matthias; Stahlhoff, Wilhelm-Friedrich; Boese, Dirk; Breuckmann, Frank

    2014-01-01

    To evaluate the patency and the freedom of target lesion revascularization of the 4-French Pulsar-18 self-expandable (SE) nitinol stent for the treatment of long femoropopliteal occlusive disease in a two-center, prospective, all-comers registry with a follow-up period of 12 months. This registry enrolled 36 patients with symptomatic femoropopliteal long lesions for recanalization and implantation of the 4-French Pulsar-18 SE nitinol stent. Routine follow-up examination including duplex ultrasound was performed after 6 and 12 months. Primary patency was defined as no binary restenosis on duplex ultrasound (Peak systolic velocitiy ration (PSVR) Pulsar-18 SE nitinol stent for endovascular intervention of femoropopliteal disease with a mean lesion length of 182.3 ± 51.8 mm showed promising primary patency and fTLR rates after 6 and 12 months. Diabetes and renal insufficiency had no negative impact on the patency rate.

  6. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  7. Biodegradable shape-memory block co-polymers for fast self-expandable stents.

    Science.gov (United States)

    Xue, Liang; Dai, Shiyao; Li, Zhi

    2010-11-01

    Block co-polymers PCTBVs (M(n) of 36,300-65,300 g/mol, T(m) of 39-40 and 142 degrees C) containing hyperbranched three-arm poly(epsilon-caprolactone) (PCL) as switching segment and microbial polyester PHBV as crystallizable hard segment were designed as biodegradable shape-memory polymer (SMP) for fast self-expandable stent and synthesized in 96% yield by the reaction of three-arm PCL-triol (M(n) of 4200 g/mol, T(m) of 47 degrees C) with methylene diphenyl 4,4'-diisocyanate isocynate (MDI) to form the hyperbrached MDI-linked PCL (PTCM; M(n) of 25,400 g/mol and a T(m) of 38 degrees C), followed by further polymerization with PHBV-diol (M(n) of 2200 g/mol, T(m) of 137 and 148 degrees C). The polymers were characterized by (1)H NMR, GPC, DSC, tensile test, and cyclic thermomechanical tensile test. PCTBVs showed desired thermal properties, mechanical properties, and ductile nature. PCTBV containing 25 wt% PHBV (PCTBV-25) demonstrated excellent shape-memory property at 40 degrees C, with R(f) of 94%, R(r) of 98%, and shape recovery within 25s. PCTBV-25 was also shown as a safe material with good biocompatibility by cytotoxicity tests and cell growth experiments. The stent made from PCTBV-25 film showed nearly complete self-expansion at 37 degrees C within only 25 s, which is much better and faster than the best known self-expandable stents. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  8. Self-expanding Y stents in the treatment of central airway stenosis: a retrospective analysis.

    Science.gov (United States)

    Gompelmann, Daniela; Eberhardt, Ralf; Schuhmann, Maren; Heussel, Claus P; Herth, Felix J F

    2013-10-01

    Central airway obstruction (CAO) is a life-threatening situation. Stent insertion re-establishes patency of the central airways. Self-expanding metallic Y stents have been available since 2005, widening the spectrum of interventional bronchoscopic techniques. Retrospective analysis of all patients treated for CAO with a self-expanding metallic Y stent at the Thoraxklinik Heidelberg between May 2005 and January 2009. A total of 43 patients aged 26-81 had a metallic Y stent inserted endoscopically for the treatment of CAO; 39 of these patients (90.7%) had CAO due to malignant disease, four patients (9.3%) due to benign disease. In all 43 patients, the Y stent was deployed without any complications. A longitudinal follow up was possible in 32 of the 43 patients. The stents remained in situ for an average of 107.1 days (range 1-640 days). In 29 patients with malignant CAO the stenosis was successfully overcome with a Y stent; 11 of these patients died within 6 weeks following stent insertion. On follow up the remaining 18 patients showed immediate improvement of dyspnoea. Eight out of the 18 patients (44.4%) tolerated the stent without problems, two (11.1%) required further stenting, six (33.3%) had complications such as increased secretions, cough, dyspnoea or granulation tissue formation. The stent was removed in one patient (5.6%) due to increased secretions, and in another (5.6%) as the stent was no longer required due to successful tumour-specific therapy. Placement of Y stents in symptomatic CAO allows for quick relief of symptoms. Severe complications are rare. Stent removal is possible after successful treatment of the primary tumour. However, the prognostic indicator for survival is the underlying malignancy.

  9. Physical property and MR imaging of self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee; Kang, Sung Gwon; Cho, Young Kook; Kim, Hyung Jin; Lim, Myung Kwan; Cho, Soon Gu; Yoh, Kyu Tong; Suh, Chang Hae [Inha Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    In order to furnish basic information prior to their use, the physical properties of various self-expandable metallic stents and their MR characteristics were evaluated. Four commercially available self-expandable metallic stents-Gianturco-the Rosch, Hanaro, Memotherm, and Wallstent-were used in this study. For evaluation of the physical properties of each, hoop strengths and changes in radii according to the degrees of longitudinal flexion were compared. Stent characteristics seen on MR images were evaluated by measuring magnetic torque and by comparing images obtained in the vascular phantom using SE T1TI, FSE T2WI, and FMPSPGR sequences. These images were analyzed with special emphasis on artifact size and the apparant shepe of the stent. Hoop strength was greatest in the Gianturco-Rosch stent, followed by the Memotherm, Hanaro, and Wallstent. When flexed in the longitudinal axis, the radius of the Hanaro and Memotherm stent decreased slightly as a larger flexion angle was applied. When this was 90 deg, however, the connection of the Gianturco-Rosch stent collapsed. In contrast, the radius of the Wallstent became larger as a larger flexion angle was applied. At the portal of the MR imaging unit, neither the Memotherm nor Wallstent showed deflection; except for a thin hyperintense rim at both ends, their images were excellent, and the lumina of these stents were also clearly seen. In contrast, the Gianturco-Rosch and Hanaro stent demonstrated large deflexion and showed a severe black-hole artifact. As a result, visualization of the stents themselves and their lumina was impossible. The Gianturco-Rosch stent showed greatrer hoop strength than the others. The Wallstent showed good longitudinal flexibility and was thought to be effective in tortuous vessels. For follow-up after placement, especially when the nonferromagnetic Memotherm and Wallstent are used, MR imaging appears to be safe and useful.=20.

  10. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    International Nuclear Information System (INIS)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho

    2007-01-01

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates

  11. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho [Chonbuk National University Medical School and Hospital, Chonju (Korea, Republic of)

    2007-10-15

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates.

  12. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  13. Feasibility study for the investigation of Nitinol self-expanding stents by neutron techniques

    International Nuclear Information System (INIS)

    Rogante, M.; Pasquini, U.; Rosta, L.; Lebedev, V.

    2011-01-01

    In this paper, neutron techniques - in particular, small angle neutron scattering (SANS) and neutron diffraction (ND) - are considered for the non-destructive characterization of Nitinol artery stents. This roughly equiatomic (50Ni-50Ti at%) shape memory alloy (SMA) exhibits significant properties of superelasticity and biocompatibility that make it suitable to be typically used as smart material for medical implants and devices. Nitinol self-expanding artery stents, as permanent vascular support structures, supply an ideal option to bypass surgery, but they are submitted for the whole of patient's life to the dynamical stress of the artery pulsation and the aggression from the biological environment. These stents, consequently, can suffer from wear and fracture occurrence likely due to a variety of cyclic fatigue, overload conditions and residual stresses. Neutrons have recently become a progressively more important probe for various materials and components and they allow achieving information complementary to those obtained from the traditional microstructural analyses. The outputs from the preliminary works already carried out in this field consent to consider neutron techniques capable to contribute to the development of these crucial medical implants. The achievable results can yield trends adoptable in monitoring of the stent features. -- Research Highlights: → Neutron techniques can contribute to develop Nitinol self-expanding artery stents. → Neutrons investigations can help avoiding wear and fracture events in Nitinol stents. → Neutron techniques can yield trends adoptable in monitoring of Nitinol stent features. → SANS is able to perform a micro- and nano-scale characterization of Nitinol stents. → Neutron Diffraction helps assessing stresses due to the exercise in Nitinol stents.

  14. Self-expandable metal stents in the treatment of benign anastomotic stricture after rectal resection for cancer.

    Science.gov (United States)

    Lamazza, A; Fiori, E; Sterpetti, A V; Schillaci, A; Scoglio, D; Lezoche, E

    2014-04-01

    To evaluate the use of self-expandable metallic stents to treat patients with symptomatic benign anastomotic stricture after colorectal resection. Ten patients with a benign symptomatic anastomotic stricture after colorectal resection were treated with endoscopic placement of a self-expandable metal stent. The stent was placed successfully in all 10 patients without any major morbidity. At a mean follow-up of 18 months the stenosis was resolved successfully in 7 out 10 patients (70%). The remaining three patients were subsequently treated successfully with balloon dilatation. Self-expandable metal stents represent a valid alternative to balloon dilatation to treat patients with benign symptomatic anastomotic stricture after colorectal resection for cancer. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  15. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  16. Palliative of malignant esophageal stenoses and their complications using self-expandable stets

    International Nuclear Information System (INIS)

    Manova, G.; Totev, M.; Kamburov, V.; Tcherveniakov, A.; Spaskov, S.

    2006-01-01

    Full text: One of the best modalities to improve quality of live of the patients with malignant dysphagia, who are bad candidates for surgery, is stenting with self-expandable metal stents. In critically ill patients it remains the last therapeutic possibility. The aim of the study is to evaluate the combined endoscopic- radiological approach in treatment of the dysphagia with malignant origin using self expandable metal stents in unsuitable for surgery patients. Between 10.2002 and 04.2006 we studied 42 consecutive patients (36 males and 6 females), mean age 63.3 (SD=8.28) years with advanced (range 3, 4 and 5) dysphagia. All patients had metastatic disease, four of them were critically ill (aspiration pneumonia due to malignant fistula). The manipulation was performed by one endoscopist, one radiologist and one assistant with combined endoscopically- radiological approach. After obtaining informed consent and sedating the patient, we insert a firm canula trough the scope and instill iodine contrast. We mark the edges of the stenosis on the skin, choose a stent with proper length, place a stiff guide wire via the endoscopic channel and remove the scope. We used covered self-expandable metal stents FerX-ELLA (Hradec Kralove, Czechs Republic) with antireflux valves. We insert the delivery system over the wire, position the prosthesis under x-ray control according to the skin marks and release the stent. In 34 cases the reason for dysphagia was primary tumor (7 - middle third, 22 - distal third of the esophagus, five - cardia). In five cases the dysphagia was due to recurrence after gastrooesophagoplasty. Another five patients presented with malignant esophageal-respiratory fistula. In 52% the histology of the tumor revealed adenocarcinoma, in 40% - squamocellular and in 8% adenosquamous carcinoma. In tree cases there was extrinsic compression due to mediastinal mass (two bronchial carcinoma, one lymphoma). Technically successful one-step manipulation was achieved in

  17. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  18. Bubble transport in bifurcations

    Science.gov (United States)

    Bull, Joseph; Qamar, Adnan

    2017-11-01

    Motivated by a developmental gas embolotherapy technique for cancer treatment, we examine the transport of bubbles entrained in liquid. In gas embolotherapy, infarction of tumors is induced by selectively formed vascular gas bubbles that originate from acoustic vaporization of vascular droplets. In the case of non-functionalized droplets with the objective of vessel occlusion, the bubbles are transported by flow through vessel bifurcations, where they may split prior to eventually reach vessels small enough that they become lodged. This splitting behavior affects the distribution of bubbles and the efficacy of flow occlusion and the treatment. In these studies, we investigated bubble transport in bifurcations using computational and theoretical modeling. The model reproduces the variety of experimentally observed splitting behaviors. Splitting homogeneity and maximum shear stress along the vessel walls is predicted over a variety of physical parameters. Maximum shear stresses were found to decrease with increasing Reynolds number. The initial bubble length was found to affect the splitting behavior in the presence of gravitational asymmetry. This work was supported by NIH Grant R01EB006476.

  19. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul

    2011-01-01

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 ± 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  20. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2011-07-15

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  1. Self-expanding intracoronary stents in the treatment of coronary artery disease: new developments and future directions

    NARCIS (Netherlands)

    Lu, H.; Grundeken, M. J.; Koch, K. T.; Wykrzykowska, J. J.

    2013-01-01

    The first stent implanted in the human coronary circulation was a self-expandable (SE) stent and was introduced almost simultaneously with the first balloon-expandable (BE) stents in the late 1980s. Nowadays, the majority of the available stents are delivered by balloon expansion. While BE stents

  2. Safety and efficacy of self-expandable metal stents for obstructive proximal and distal large bowel cancer.

    Science.gov (United States)

    Mitra, V; Hu, M; Majumdar, D; Krishnan, V; Chaudhury, B; Hancock, J; Dwarakanath, D

    2017-03-01

    Self-expandable metal stents are often used to treat obstructive large bowel cancers. This study assessed the safety and efficacy of colonic stent insertion carried out in a district general hospital. Methods A retrospective review was carried out between 1 January 2007 and 28 February 2014 to identify patients who underwent stent insertion for malignant colorectal obstruction. Results Seventy-five patients (median age 75.2 years, 70.6% male) with primary colorectal cancer underwent stent insertion - 53 underwent semi-elective self-expanded metal stent insertion (for subacute bowel obstruction) and 22 had emergency stent inserted (for acute bowel obstruction). The majority (88%) had self-expanded metal stents inserted for palliation. Technical and clinical success rates were 98.7% and 91.2%, respectively. One patient had stent-related perforation; there was no procedure-related mortality. Conclusion This study shows that self-expanded metal stent insertion in malignant colorectal obstruction is safe and effective and can be successfully delivered in a district general hospital with high technical and clinical success rates.

  3. A clinical evaluation of endoscopically placed self-expanding metallic stents in patients with acute large bowel obstruction

    DEFF Research Database (Denmark)

    Pommergaard, H C; Vilmann, P; Jakobsen, H L

    2009-01-01

    BACKGROUND AND AIMS: Self-expanding metallic stents (SEMS) have since 1991 established themselves as an option in the treatment of large bowel obstruction. The aim of this study was to evaluate the use of SEMS in management of acute colorectal obstructions at a Danish Surgical Gastroenterology...

  4. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures : a prospective, multicenter cohort study

    NARCIS (Netherlands)

    Walter, Daisy; Laleman, Wim; Jansen, Jeroen M; van Milligen de Wit, A W M; Weusten, Bas L; van Boeckel, Petra G; Hirdes, Meike M; Vleggaar, FP; Siersema, Peter D

    2015-01-01

    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel

  5. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study

    NARCIS (Netherlands)

    Walter, D.; Laleman, W.; Jansen, J.M.; Milligen de Wit, A.W. van; Weusten, B.L.; Boeckel, P.G. van; Hirdes, M.M.; Vleggaar, F.P.; Siersema, P.D.

    2015-01-01

    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel

  6. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; van Hooft, Jeanin E.

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective

  7. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  8. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  9. Effects of the temporary placement of a self-expandable metallic stent in benign pyloric stenosis.

    Science.gov (United States)

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-07-01

    The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration.

  10. Removal of self expandable metallic airway stent: A rare case report

    Directory of Open Access Journals (Sweden)

    Rakesh K Chawla

    2013-01-01

    Full Text Available Covered self expandable metallic airway stents (SEMS have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after placement of SEMS, she developed cough with dyspnoea, video bronchoscopy showed stenosis above the level of stent with granulation tissue inside the stent, stent fracture in lower part and stent migration to right main bronchus, thus she had all conceivable complications of stent placement. The stent was removed with the help of rigid bronchoscope under general anaesthesia. She was discharged the following day. The case is being reported because it was unique in having all the possible complications of stent placement, and rare as we could take out the stent in Toto. Thirdly, the stent could be removed without any complication.

  11. An intriguing design concept to enhance the pulsatile fatigue life of self-expanding stents.

    Science.gov (United States)

    Hsiao, Hao-Ming; Yin, Ming-Ting

    2014-02-01

    Intravascular stenting has emerged as the primary treatment for vascular diseases and has received great attention from the medical community since its introduction two decades ago. The endovascular self-expanding stent is used to treat peripheral artery diseases; however, once implanted, these stents suffer from various cyclic motions caused by pulsatile blood pressure and daily activities. Due to this challenging environment, fatigue performance has become a critical issue for stent design. In this paper, a simple yet intriguing concept of stent design aimed at enhancing pulsatile fatigue life is investigated. The concept of this design is to shift the highly concentrated stresses/strains away from the crown and re-distribute them along the stress-free bar arm by tapering its strut width. Finite element models were developed to evaluate the mechanical integrity and pulsatile fatigue resistance of the stent to various loading conditions. Results show that the fatigue safety factor jumped to 2.5-3.0 times that of the standard stent with constant strut width. This is astonishing considering that the stent profile and scaffolding were not compromised. The findings of this paper provide an excellent approach to the optimization of future stent design to greatly improve stent fatigue performance.

  12. Fully covered self-expanding metal stents are effective for benign esophagogastric disruptions and strictures.

    Science.gov (United States)

    Wilson, Jennifer L; Louie, Brian E; Farivar, Alexander S; Vallières, Eric; Aye, Ralph W

    2013-12-01

    Self-expanding fully covered metal stents (CSs) are ideal for use in benign esophagogastric disease. We reviewed our experience with CS to evaluate outcomes, to determine a role for CS in a standard treatment for benign esophageal conditions, and to compare our results with recently published studies. We performed a retrospective chart review from 2005 to 2012. A total of 57 CSs were placed in 44 patients. Indications were stricture (11 patients), anastomotic leak (20), perforation (7), and tracheoesophageal fistulae (6). For GI tract disruptions, open repair or diversion was avoided in 31/33 patients (93.9 %) but required an associated drainage procedure in 22/33 (67 %) patients. Resolution does not depend on achieving radiological control with 6/26 (23 %) having evidence of a persistent leak. Benign strictures were dilated at a mean of 3.7 times prior to stenting. Adjunctive intra-mucosal steroid injections were used in 8/11 patients. Stents were removed at a mean of 33 days. At a mean of 283 days of follow-up, 6/11 (54.5 %) had symptom resolution. The most common complication was stent migration occurring in 17.5 % of patients overall. Covered stents are an effective adjunct in the management of benign upper gastrointestinal tract fistulae, leaks, perforations and benign strictures.

  13. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    International Nuclear Information System (INIS)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro

    2012-01-01

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  14. Mechanical characteristics of self-expandable metallic stents: in vitro study with three types of stress

    International Nuclear Information System (INIS)

    Lee, Byung Hee; Kim, Kie Hwan; Chin, Soo Yil

    1998-01-01

    To obtain objective and comparable data for mechanical characteristics of self-expandable metallic stents widely used in the treatment of biliary obstruction. The stents tested were the 6 and 8 mm-band Hanaro spiral stent, Gianturco-Rosch Z stent, Wallstent, Ultraflex stent, and Memotherm stent. Each was subjected to three types of load:point, area, and circular. We analyzed their mechanical characteristics (resistance force, expansile force, and elasticity) according to these three types of stress. With regard to point loads, the Memotherm stent showed the highest resistance force and expansile force. The 8 mm-band Hanaro stent showed the lowest resistance force and the Gianturco-Rosch Z stent and Ultraflex stent showed lower expansile force. With regard to area loads, the Ultraflex stent showed the highest resistance force. The 6 mm-band Hanaro stent, Gianturco-Rosch Z stent, and Ultraflex stent showed higher expansile force. The 8 mm-band Hanaro stent showed the lowest value in both resistance force and expansile force. For circular loads, the Memotherm stent showed the highest resistance force and the Ultraflex stent and Wallstent showed lower value. Under all types of stress, the Hanaro stent and Memotherm stent were completely elastic, and the Ultraflex stent and Wallstent showed a wide gap between resistance force and expansile force. In clinical practice, awareness of the mechanical characteristics of each stent might help in choosing the one which is most suitable, according to type of biliary obstruction. =20

  15. Endoscopic removal and trimming of distal self-expandable metallic biliary stents

    Science.gov (United States)

    Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori; Tsuchida, Akihiko

    2011-01-01

    AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 ± 71.5 d vs 166.2 ± 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. PMID:21677835

  16. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.

    Science.gov (United States)

    Kim, Ji Won; Jeong, Ji Bong; Lee, Kook Lae; Kim, Byeong Gwan; Ahn, Dong Won; Lee, Jae Kyung; Kim, Su Hwan

    2015-02-07

    To compare the clinical outcomes of uncovered and covered self-expandable metal stent placements in patients with malignant duodenal obstruction. A total of 67 patients were retrospectively enrolled from January 2003 to June 2013. All patients had symptomatic obstruction characterized by nausea, vomiting, reduced oral intake, and weight loss. The exclusion criteria included asymptomatic duodenal obstruction, perforation or peritonitis, concomitant small bowel obstruction, or duodenal obstruction caused by benign strictures. The technical and clinical success rate, complication rate, and stent patency were compared according to the placement of uncovered (n = 38) or covered (n = 29) stents. The technical and clinical success rates did not differ between the uncovered and covered stent groups (100% vs 96.6% and 89.5% vs 82.8%). There were no differences in the overall complication rates between the uncovered and covered stent groups (31.6% vs 41.4%). However, stent migration occurred more frequently with covered than uncovered stents [20.7% (6/29) vs 0% (0/38), P stent patency was longer in uncovered than in covered stents [251 d (95%CI: 149.8 d-352.2 d) vs 139 d (95%CI: 45.5 d-232.5 d), P stent (70 d) and covered stent groups (60 d). Uncovered stents may be preferable in malignant duodenal obstruction because of their greater resistance to stent migration and longer stent patency than covered stents.

  17. Mechanical characteristics of self-expandable metallic stents: in vitro study with three types of stress

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Hee; Kim, Kie Hwan; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1998-09-01

    To obtain objective and comparable data for mechanical characteristics of self-expandable metallic stents widely used in the treatment of biliary obstruction. The stents tested were the 6 and 8 mm-band Hanaro spiral stent, Gianturco-Rosch Z stent, Wallstent, Ultraflex stent, and Memotherm stent. Each was subjected to three types of load:point, area, and circular. We analyzed their mechanical characteristics (resistance force, expansile force, and elasticity) according to these three types of stress. With regard to point loads, the Memotherm stent showed the highest resistance force and expansile force. The 8 mm-band Hanaro stent showed the lowest resistance force and the Gianturco-Rosch Z stent and Ultraflex stent showed lower expansile force. With regard to area loads, the Ultraflex stent showed the highest resistance force. The 6 mm-band Hanaro stent, Gianturco-Rosch Z stent, and Ultraflex stent showed higher expansile force. The 8 mm-band Hanaro stent showed the lowest value in both resistance force and expansile force. For circular loads, the Memotherm stent showed the highest resistance force and the Ultraflex stent and Wallstent showed lower value. Under all types of stress, the Hanaro stent and Memotherm stent were completely elastic, and the Ultraflex stent and Wallstent showed a wide gap between resistance force and expansile force. In clinical practice, awareness of the mechanical characteristics of each stent might help in choosing the one which is most suitable, according to type of biliary obstruction. =20.

  18. Efficacy of Self-Expandable Metallic Stent Inserted for Refractory Hemorrhage of Duodenal Cancer

    Directory of Open Access Journals (Sweden)

    Takashi Orii

    2016-05-01

    Full Text Available Because of advances in the technology of gastrointestinal endoscopy and improvements in the quality of stents, it has become routine to place a stent as palliative therapy for malignant gastrointestinal obstruction. On the other hand, stent placement for malignant gastrointestinal hemorrhage has scarcely been reported, although it may be performed for hemorrhage of the esophageal varicose vein. We recently experienced a patient with refractory hemorrhage from an unresectable duodenal cancer who underwent placement of a self-expandable metallic stent (SEMS and thereafter had no recurrence of the hemorrhage. A 46-year-old man underwent laparotomy to radically resect a cancer in the third portion of the duodenum, which invaded widely to the superior mesenteric vein and its branches and was considered unresectable. After stomach-partitioning gastrojejunostomy was performed, chemotherapy was initiated according to the regimen of chemotherapy of far advanced gastric cancer. One year and 4 months after induction of chemotherapy, gastrointestinal hemorrhage occurred. Upper gastrointestinal endoscopy revealed the hemorrhage oozing from the duodenal cancer, and endoscopic hemostasis, such as injection of hypertonic saline epinephrine and argon plasma coagulation, was unsuccessful. Twenty days after emergence of the hemorrhage, an endoscopic covered SEMS was placed with confirmation by fluoroscopy. Immediately after placement of the stent, the tarry stool stopped and the anemia ceased to progress. The recurrence of the hemorrhage has not been confirmed without migration of the stent. SEMS is an effective hemostatic procedure for malignant refractory hemorrhage.

  19. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup

    1995-01-01

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction

  20. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  1. Novel characteristics of traction force in biliary self-expandable metallic stents.

    Science.gov (United States)

    Hori, Yasuki; Hayashi, Kazuki; Yoshida, Michihiro; Naitoh, Itaru; Ban, Tesshin; Miyabe, Katsuyuki; Kondo, Hiromu; Nishi, Yuji; Umemura, Shuichiro; Fujita, Yasuaki; Natsume, Makoto; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2017-05-01

    In recent years, knowledge concerning the mechanical properties of self-expandable metallic stents (SEMS) has increased. In a previous study, we defined traction force and traction momentum and reported that these characteristics are important for optimal stent deployment. However, traction force and traction momentum were represented as relative values and were not evaluated in various conditions. The purpose of the present study was to measure traction force in various situations assumed during SEMS placement. Traction force and traction momentum were measured in non-stricture, stricture, and angled stricture models using in-house equipment. Stricture and angled stricture models had significantly higher traction force and traction momentum than those of the non-stricture model (stricture vs non-stricture: traction force, 7.2 N vs 1.4 N, P stent influenced the traction force. Clinicians should be aware of the transition of the traction force and should schedule X-ray imaging during SEMS placement. © 2017 Japan Gastroenterological Endoscopy Society.

  2. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-02-15

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction.

  3. Broncho-vascular fistulas from self-expanding metallic stents: A retrospective case review

    Directory of Open Access Journals (Sweden)

    Chirag Choudhary

    2013-01-01

    Full Text Available To highlight a potentially fatal complication of broncho-vascular fistula arising from the self expanding metallic stent (SEMS placement. We retrospectively analyzed five patients with benign and malignant airway diseases, who developed tracheo/broncho-vascular fistulas following SEMS placement in our tertiary care setting. All patients received either Wallstent or Ultraflex® stent (Boston Scientific, Natick, MA between 1999 and 2007. All patients had received adjunct therapy such as balloon bronchoplasty, laser therapy or electrocautery. Most patients presented with massive hemoptysis. A total of 483 SEMS were placed during this period. SEMS placement can be complicated by Broncho-vascular fistula formation. True incidence and precise time interval between the insertion of stent and onset of this complication is unknown. Additional therapeutic modalities to maintain stent patency may enhance the risk of fistula formation. SEMS should only be used in a select sub-group of patients, after exhaustive evaluation of other treatment options. These cases provide evidence that broncho-vascular fistulas can develop at any time following SEMS placement, suggesting the need for a more cautious approach, especially while using them for a long term management. In benign airway disease, the stent should be removed as soon as healing has taken place.

  4. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  5. Ayres' bifurcated solar model

    International Nuclear Information System (INIS)

    Kalkofen, W.

    1985-01-01

    The assumptions of Ayres' model of the upper solar atmosphere are examined. It is found that the bistable character of his model is postulated - through the assumptions concerning the opacity sources and the effect of mechanical waves, which are allowed to destroy the CO molecules but not to heat the gas. The neglect of cooling by metal lines is based on their reduced local cooling rate, but it ignores the increased depth over which this cooling occurs. Thus, the bifurcated model of the upper solar atmosphere consists of two models, one cold at the temperature minimum, with a kinetic temperature of 2900 K, and the other hot, with a temperature of 4900 K. 8 references

  6. Aortic anomalies in an adolescent with the Williams' elfin facies syndrome

    International Nuclear Information System (INIS)

    Williams, R.L.; Azouz, E.M.

    1984-01-01

    An adolescent with classical Williams' syndrome who presented with hypertensive encephalopathy is described. He had the unusual combination of supravalvular aortic stenosis, long segment coarctation of the aorta, aortic hypoplasia and a high bifurcation of the abdominal aorta. Surgical resection of the coarctation was required; however, the patient has remained moderately hypertensive. The aortic anomalies in this syndrome are reviewed and their frequency and importance examined. (orig.)

  7. Bifurcations sights, sounds, and mathematics

    CERN Document Server

    Matsumoto, Takashi; Kokubu, Hiroshi; Tokunaga, Ryuji

    1993-01-01

    Bifurcation originally meant "splitting into two parts. " Namely, a system under­ goes a bifurcation when there is a qualitative change in the behavior of the sys­ tem. Bifurcation in the context of dynamical systems, where the time evolution of systems are involved, has been the subject of research for many scientists and engineers for the past hundred years simply because bifurcations are interesting. A very good way of understanding bifurcations would be to see them first and study theories second. Another way would be to first comprehend the basic concepts and theories and then see what they look like. In any event, it is best to both observe experiments and understand the theories of bifurcations. This book attempts to provide a general audience with both avenues toward understanding bifurcations. Specifically, (1) A variety of concrete experimental results obtained from electronic circuits are given in Chapter 1. All the circuits are very simple, which is crucial in any experiment. The circuits, howev...

  8. Safety and Efficacy of a Fully Covered Self-Expandable Metallic Stent in Benign Airway Stenosis.

    Science.gov (United States)

    Fortin, Marc; Lacasse, Yves; Elharrar, Xavier; Tazi-Mezalek, Rachid; Laroumagne, Sophie; Guinde, Julien; Astoul, Philippe; Dutau, Hervé

    2017-01-01

    The use of self-expandable metallic stents (SEMS) in benign airway disease was the object of a boxed warning from the United States Food and Drug Administration in 2005 due to the risk of stent-related complications and difficulties associated with their removal. Third-generation fully covered SEMS have been commercialized since this warning and theoretically should not present the same difficulties associated with removal as they cannot become embedded in the airway mucosa. We aimed to examine the safety and efficacy of a specific third-generation SEMS, the Silmet stent. We reviewed the records of all patients treated for benign airway stenosis with third-generation Silmet SEMS from January 2011 to December 2015 at the North Hospital of Marseilles, France. Forty SEMS were inserted in 30 patients over this period. Twenty (50.0%) stents were removed because of stent-related complications after a median of 77.0 ± 96.6 days (migration 32.5%, granulation tissue formation 7.5%, subjective intolerance 5.0%, mucus plugging 2.5%, laryngeal edema 2.5%). There were no cases of stent-related mortality. All complications were managed successfully endoscopically. Thirty-six stents (90.0%) were removed successfully after a median of 122.0 ± 113.2 days without any complications. The clinical success rate of stent treatment was 40.7%. Third-generation SEMS are a safe treatment option for complex benign airway stenosis, but complications requiring stent removal are frequent. Further studies are needed to compare the performance of third-generation SEMS and silicone stents in benign airway stenosis. © 2017 S. Karger AG, Basel.

  9. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    Science.gov (United States)

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  10. Safety and benefits of self-expandable metallic stents with chemotherapy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Miyabe, Katsuyuki; Hayashi, Kazuki; Nakazawa, Takahiro; Sano, Hitoshi; Yamada, Tomonori; Takada, Hiroki; Naitoh, Itaru; Shimizu, Shuya; Kondo, Hiromu; Nishi, Yuji; Yoshida, Michihiro; Umemura, Shuichiro; Hori, Yasuki; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2015-07-01

    The influence of chemotherapy on placement of self-expandable metallic stents (SEMS) for malignant gastric outlet obstruction (MGOO) has not been evaluated extensively. We investigated the influence of chemotherapy on the clinical outcomes of SEMS placement for MGOO. A total of 152 cancer patients with MGOO from a university hospital and affiliate hospitals were included. The patients were classified according to chemotherapy status and evaluated for palliative efficacy and safety of SEMS placement. Technical success rate, time to oral intake, and parameters indicating improvement of physical condition did not differ between the with- and without-chemotherapy groups after stent placement. Re-intervention and stent migration were significantly more frequent in the with-chemotherapy group than in the without-chemotherapy group after stent placement (re-intervention, 32.4% vs 7.8%, P = 0.0005; stent migration, 13.5% vs 1.7%, P = 0.0097). The frequency of adverse events did not differ between the with- and without-chemotherapy groups. Although chemotherapy after stent placement was an independent predictive factor for shortening the stent patency period (hazard ratio [HR], 3.10; P = 0.0264), the use of additional stents facilitated uneventful recovery and further prolonged survival time (HR, 0.60; P = 0.0132). Various cancer patients with MGOO can undergo SEMS placement safely regardless of chemotherapy, and concurrent chemotherapy after stent placement can prolong survival time, although re-intervention and stent migration may be increased. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  11. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Jin, Bo Hwan [Medical Science Research Center, Ajou University School of Medicine, Suwon (Korea, Republic of); Lee, June Woo [Dept. of Radiology, Busan National University College of Medicine, Busan (Korea, Republic of)

    2012-02-15

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm{sup 2} (4 week) and 4.92 mm{sup 2} (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  12. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    International Nuclear Information System (INIS)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae; Jin, Bo Hwan; Lee, June Woo

    2012-01-01

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm 2 (4 week) and 4.92 mm 2 (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  13. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature.

    Science.gov (United States)

    van Halsema, Emo E; Rauws, Erik A J; Fockens, Paul; van Hooft, Jeanin E

    2015-11-21

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher's exact test. A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO.

  14. A new approach to improve the local compressive properties of PPDO self-expandable stent.

    Science.gov (United States)

    Zhao, Fan; Xue, Wen; Wang, Fujun; Yu, Chenglong; Xu, Haiyan; Hao, Yi; Wang, Lu

    2017-04-01

    The radial performance of bioabsorbable polymeric intravascular stents is extremely important in assessing the efficiency of these devices in expanding narrow lumen, reducing stent recoil, and recovering to their original states after suffering from pulsating pressure. However, these stents remain inferior to metallic stents. Several thermal treatment conditions (60°C, 80°C, and 100°C for 1h) were investigated to improve the characteristics of poly(p-dioxanone) (PPDO) self-expandable stents. The local compressive force, stiffness, and viscoelasticity of these stents were also evaluated. Wide-angle X-ray diffraction and different scanning calorimetry measurements were performed to evaluate the recrystalline and thermodynamic changes of molecular chains. The declining conformer entropy of PPDO monofilaments was examined via energy analysis. The untreated stents had compressive modules of 514.80±70.59mN/mm, which was much higher than those of 80°C and 100°C treated stents (332.35±66.08mN/mm and 394.31±64.71mN/mm, respectively). Nevertheless, 100°C annealing stents had less stress relaxation and prior elastic recovery rate of 82.32±3.43mN and 92.55±1.61%, respectively, showing a much better shape stability than untreated stents (139.51±16.67mN and 86.18±3.57%, respectively). These findings present important clinical implications in the stent manufacturing process and warrant further study to develop new bioabsorbable stents with outstanding clinical efficacy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  16. Management of benign biliary strictures with a novel retrievable self-expandable metal stent.

    Science.gov (United States)

    Hu, Bing; Leung, Joseph W; Gao, Dao Jian; Wang, Tian Tian; Wu, Jun

    2014-03-01

    Endoscopic placement of covered self-expandable metal stent (SEMS) has gained popularity in the management of benign biliary strictures (BBS). The existing SEMS has been designed primarily to palliate malignant biliary obstruction and has a high frequency of stent migration, difficulty in retrieval and stricture recurrence after stent removal. This study aimed to design a novel retrievable SEMS dedicated to the treatment of extrahepatic BBS and evaluate its clinical efficacy and safety. A short fully covered SEMS (FCSEMS) with a retrieval lasso was designed for the specific treatment of BBS. A total of 45 patients with segmental extrahepatic BBS were included in this study. The stent was placed entirely inside the bile duct with only the retrieval lasso extending from the papilla. The stents were recommended to be in situ for 6 to 12 months before removal. The FCSEMS was successfully placed in all 45 patients. In all, 33 patients had their FCSEMS successfully removed after a mean period of 8.6 ± 3.7 (range 2-15.5) months. Stent migration occurred in 9.1% of the patients. During a mean follow-up of 18.9 months after stent removal, recurrent stricture was found in 2 (6.1%) patients and was successfully treated with a second FCSEMS. Overall, the strictures resolved in 30/33 (90.9%) patients. Intraductal placement of a short FCSEMS is suitable for the treatment of segmental extrahepatic BBS. This new removable design offered prolonged stenting and drainage for BBS for up to one year with minimal complications. © 2013 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  17. Treatment of Postoperative Leaks of the Upper Gastrointestinal Tract with Colonic Self-Expandable Metal Stents.

    Science.gov (United States)

    Sousa, Paula; Castanheira, António; Martins, Diana; Pinho, Juliana; Araújo, Ricardo; Cancela, Eugénia; Ministro, Paula; Silva, Américo

    2017-07-01

    The use of self-expandable metal stents (SEMS) for the treatment of postoperative leaks of the upper gastrointestinal tract is already established. However, there are discrepancies between the relatively small caliber of the esophageal stents available and the postsurgical luminal size, which may determine an inadequate juxtaposition. As colonic stents have a bigger diameter, they might be more adequate. Additionally, stents with a larger diameter might have a lower risk of migration. The aim of this study was to evaluate the efficacy and complications associated with the use of colonic fully covered SEMS (FSEMS) in the treatment of postoperative leaks in critical patients. All patients with postoperative leaks of the upper gastrointestinal tract treated with colonic stents (Hanarostent® CCI) between 2010 and 2013 were retrospectively included. Four patients with postoperative leaks were treated with colonic SEMS. The underlying surgeries were a gastric bypass, an esophagogastrectomy for Boerhaave syndrome, a primary repair of esophagopleural fistula due to Boerhaave syndrome, and an esophagectomy due to esophageal cancer. The leaks were detected on average 17 days after the initial surgery. All patients needed admission to a critical care unit after index surgery. Stent placement was technically feasible in all patients. The median residence time of the stents was 7 weeks, and no complications were verified when they were removed. There were no cases of stent migration. The treatment was successful in all patients, with complete healing of the leaks. The placement of colonic FSEMS seems to be successful and safe in the treatment of postoperative leaks of the upper gastrointestinal tract.

  18. Self-Expandable Metal Stent for Closure of a Large Leak after Total Gastrectomy

    Directory of Open Access Journals (Sweden)

    G. Curcio

    2010-08-01

    Full Text Available In recent years, self-expandable metallic stents (SEMSs have emerged as a promising treatment alternative for the bridging and sealing of esophageal perforations and extensive anastomotic leaks after esophageal resection or total gastrectomy. A 56-year-old woman underwent a total gastrectomy with Roux-en-Y end-to-side esophagojejunostomy for a gastric signet ring cell carcinoma. Ten days later, esophagogastroduodenoscopy showed a 2 cm fistula in the distal end of the Roux limb of the anastomosis. This was confirmed by gastrografin esophagography. The patient was started on total parenteral nutrition. Having deemed clipping treatment for this fistula unfeasible, we decided to insert a partially silicone-coated SEMS (Evolution Controlled Release Esophageal Stent System, Cook Medical, Winston-Salem, N.C., USA. The stent was removed after ten days. Gastrografin esophagography showed no further contrast extravasation, and esophagogastroduodenoscopy showed closure of the fistula. No clinical complications were observed, and the patient was able to start normal per os nutrition. In conclusion, the treatment of symptomatic leaks in patients who have undergone esophagojejunostomy is challenging, and leakage from the jejunal stump can be a potentially serious complication. In the treatment of leakage after total gastrectomy, plastic stents (which are either too light or exercise too little radial force and totally covered metallic stents may not adhere sufficiently to the esophagojeujunal walls and, as a result, migrate beyond the anastomosis. The promising results of this report suggest that early stenting, using a partially silicone-coated SEMS, is a feasible alternative to surgical treatment in this category of patients.

  19. Evaluation of anti-migration properties of biliary covered self-expandable metal stents.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-08-14

    To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.

  20. Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma.

    Science.gov (United States)

    Chung, Kwang Hyun; Lee, Sang Hyub; Park, Jin Myung; Lee, Jae Min; Ahn, Dong-Won; Ryu, Ji Kon; Kim, Yong-Tae

    2015-06-01

    The patency of self-expandable metallic stents (SEMS) is known to be better than plastic stents in the palliation of malignant biliary obstruction. However, data are scarce for obstructive jaundice caused by hepatocellular carcinoma (HCC). This study aimed to compare SEMSs and plastic stents for the palliation of obstructive jaundice in unresectable HCC. A total of 96 patients who underwent endoscopic retrograde biliary drainage with SEMSs or plastic stents were included in this retrospective analysis. The rate of successful biliary drainage, adverse events, stent patency duration, and patient survival were compared between the SEMS (n = 36) and plastic stent (n = 60) groups. The rate of successful biliary drainage was similar between the SEMS and plastic stent groups (25/36 [69.4 %] vs. 39/60 [65.0 %]; P = 0.655). Adverse events occurred in 6 patients (16.7 %) in the SEMS group and 13 patients (21.7 %) in the plastic stent group (P = 0.552). The median patency duration was also similar between the two groups (60 vs. 68 days; P = 0.396). The median patient survival was longer in the plastic stent group than in the SEMS group (123 vs. 48 days; P = 0.005). SEMSs were not superior to plastic stents for the palliation of malignant biliary obstruction in HCC with regard to successful drainage, stent patency, and adverse events. Patient survival was better in the plastic stent group. Given the lower cost, plastic stents could be a favorable option for malignant biliary obstruction caused by HCC. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Malignant pyloro-duodenal obstruction: Role of self expandable metallic stents

    International Nuclear Information System (INIS)

    Qureshi, S.; Ghazanfar, S.; Quraishy, M.S.

    2014-01-01

    Objective: To determine the outcome of duodenal stenting in palliation of patients with malignant pyloric and duodenal obstruction. Methods: The non-randomised prospective descriptive study was conducted at the Endoscopy Suite, Surgical Unit-IV, Civil Hospital, Karachi, from December 2007 to November 2010. All patients presenting with inoperable ampullary, pancreatic or biliary cancers causing duodenal obstruction and patients with resectable malignancy but unfit for surgery were included. The procedure was carried out by a single expert endoscopist under local or general anaesthaesia as required. Boston Scientific stents of variable sizes were used. Follow-up was done at 1 week, 1 month and 6 months. Data analysis was done using SPSS 15. Results: Over the study period, 159 (60%) males and 6 (40%) females were included in the study. The male-to-female ratio was 2:3. The overall age ranged from 25-80 years with a mean of 52.67+-15.07 years. Primary diagnosis was pyloric carcinoma in 7(46.6%), carcinoma Gallbladder in 4(26.6%), Duodenal carcinoma in 3(20%) and carcinoma head of pancreas in 1(6.6%). Relief of symptoms were seen in 11 (73.3%), while complications were seen in 2 (13.3%). Stents were inserted with technical success in 14 (93%) patients. Clinical success was seen in 11 (73%), with a mean survival of 74.27+-40.7 days (range: 15-180 days). No statistical significance was found when comparing the survival time with age, gender and diagnosis. Conclusion: Use of self-expandable metallic stents for gastroduodenal malignancies appears to be a feasible, safe and effective method, especially in those patients with limited life expectancy. (author)

  2. Preoperative biliary decompression preceding pancreaticoduodenectomy with plastic or self-expandable metallic stent.

    Science.gov (United States)

    Haapamäki, C; Seppänen, H; Udd, M; Juuti, A; Halttunen, J; Kiviluoto, T; Sirén, J; Mustonen, H; Kylänpää, L

    2015-06-01

    The rainage (PBD) prior to pancreaticoduodenectomy (PD) is controversial. If PBD is required, large bore self-expandable metallic stents (SEMS) are thought to maintain better drainage and have fewer postoperative complications than plastic stents. The confirming evidence is scarce. The aim of the study was to compare outcomes of surgery in patients who underwent PBD with SEMS or plastic stents deployed at endoscopic retrograde cholangiopancreatography (ERCP). This is a retrospective study of 366 patients having had PD during 2000-2009. Preceding endoscopic PBD was performed in 191 patients and nine had had percutaneous transhepatic drainage (PTD). At the time of operation, 163 patients had a plastic stent and 28 had SEMS. Due to stent exchanges, 176 plastic stents and 29 SEMS were placed in all. The stent failure rate was 7.4% for plastic stents and 3.4% for SEMS (p = 0.697). A bilirubin level under 50 µmol/L was reached by 80% of the patients with plastic stents and by 61% of the patients with SEMS (p = 0.058). A postoperative infection complication and/or a pancreatic fistula was found in 26% while using plastic stents and in 25% using SEMS (p = 1.000). In unstented patients with biliary obstruction, the bile juice was sterile significantly more often than in endoscopically stented patients (100% vs 1%, p stented and unstented patients were compared regarding postoperative infection complications, there was no significant difference between the groups (p = 0.365). Plastic stents did not differ from SEMS regarding the stent failure rate, bilirubin level decrease, amount of bacteria in the bile juice, or postoperative complications when used for PBD. The significantly higher price of SEMS suggests their use in selected cases only. © The Finnish Surgical Society 2014.

  3. One-Year Clinical Outcomes of Patients Presenting With ST-Segment Elevation Myocardial Infarction Caused by Bifurcation Culprit Lesions Treated With the Stentys Self-Apposing Coronary Stent: Results From the APPOSITION III Study.

    Science.gov (United States)

    Grundeken, Maik J; Lu, Huangling; Vos, Nicola; IJsselmuiden, Alexander; van Geuns, Robert-Jan; Wessely, Rainer; Dengler, Thomas; La Manna, Alessio; Silvain, Johanne; Montalescot, Gilles; Spaargaren, René; Tijssen, Jan G P; de Winter, Robbert J; Wykrzykowska, Joanna J; Amoroso, Giovanni; Koch, Karel T

    2017-08-01

    To investigate outcomes in patients with ST-segment elevation myocardial infarction (STEMI) after treatment with the Stentys self-apposing stent (Stentys SAS; Stentys S.A.) for bifurcation culprit lesions. The nitinol, self-expanding Stentys was initially developed as a dedicated bifurcation stent. The stent facilitates a provisional strategy by accommodating its diameter to both the proximal and distal reference diameters and offering an opportunity to "disconnect" the interconnectors, opening the stent toward the side branch. The APPOSITION (a post-market registry to assess the Stentys self-expanding coronary stent in acute myocardial infarction) III study was a prospective, multicenter, international, observational study including STEMI patients undergoing primary percutaneous coronary intervention (PCI) with the Stentys SAS. Clinical endpoints were evaluated and stratified by bifurcation vs non-bifurcation culprit lesions. From 965 patients included, a total of 123 (13%) were documented as having a bifurcation lesion. Target-vessel revascularization (TVR) rates were higher in the bifurcation subgroup (16.4% vs 10.0%; P=.04). Although not statistically significant, other endpoints were numerically higher in the bifurcation subgroup: major adverse cardiac events (MACE; 12.7% vs 8.8%), myocardial infarction (MI; 3.4% vs 1.8%), and definite/probable stent thrombosis (ST; 5.8% vs 3.1%). However, when postdilation was performed, clinical endpoints were similar between bifurcation and non-bifurcation lesions: MACE (8.7% vs 8.4%), MI (1.2% vs 0.7%), and definite/probable ST (3.7% vs 2.4%). The use of the Stentys SAS was safe and feasible for the treatment of bifurcation lesions in the setting of primary PCI for STEMI treatment with acceptable 1-year cardiovascular event rates, which improved when postdilation was performed.

  4. Aortic stenosis

    Science.gov (United States)

    ... Images Aortic stenosis Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ... ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/ ...

  5. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive......, probably caused by ischemic conditions developed before stent-decompression of the colon was revealed during the operation. The patient died in the postoperative course. We discuss the observation of patients treated with self-expanding metal stents based on the selection-strategy used to allocate patients...

  6. USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE

    Directory of Open Access Journals (Sweden)

    M. N. Kornilov

    2013-01-01

    Full Text Available Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required. 

  7. Riddling bifurcation and interstellar journeys

    International Nuclear Information System (INIS)

    Kapitaniak, Tomasz

    2005-01-01

    We show that riddling bifurcation which is characteristic for low-dimensional attractors embedded in higher-dimensional phase space can give physical mechanism explaining interstellar journeys described in science-fiction literature

  8. Reversal of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-Induced Hepatic Encephalopathy Using a Strictured Self-Expanding Covered Stent

    International Nuclear Information System (INIS)

    Cox, Mitchell W.; Soltes, George D.; Lin, Peter H.; Bush, Ruth L.; Lumsden, Alan B.

    2003-01-01

    Hepatic encephalopathy is a known complication following percutaneous transjugular intrahepatic portosystemic shunt (TIPS) placement. We describe herein a simple and effective strategy of TIPS revision by creating an intraluminal stricture within a self-expanding covered stent, which is deployed in the portosystemic shunt to reduce the TIPS blood flow. This technique was successful in reversing a TIPS-induced hepatic encephalopathy in our patient

  9. Dynamic bifurcations on financial markets

    International Nuclear Information System (INIS)

    Kozłowska, M.; Denys, M.; Wiliński, M.; Link, G.; Gubiec, T.; Werner, T.R.; Kutner, R.; Struzik, Z.R.

    2016-01-01

    We provide evidence that catastrophic bifurcation breakdowns or transitions, preceded by early warning signs such as flickering phenomena, are present on notoriously unpredictable financial markets. For this we construct robust indicators of catastrophic dynamical slowing down and apply these to identify hallmarks of dynamical catastrophic bifurcation transitions. This is done using daily closing index records for the representative examples of financial markets of small and mid to large capitalisations experiencing a speculative bubble induced by the worldwide financial crisis of 2007-08.

  10. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    Science.gov (United States)

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  11. Self-expandable metallic stent placement plus laparoscopy for acute malignant colorectal obstruction.

    Science.gov (United States)

    Zhou, Jia-Min; Yao, Li-Qing; Xu, Jian-Min; Xu, Mei-Dong; Zhou, Ping-Hong; Chen, Wei-Feng; Shi, Qiang; Ren, Zhong; Chen, Tao; Zhong, Yun-Shi

    2013-09-07

    To investigate the clinical advantages of the stent-laparoscopy approach to treat colorectal cancer (CRC) patients with acute colorectal obstruction (ACO). From April 2008 to April 2012, surgery-related parameters, complications, overall survival (OS), and disease-free survival (DFS) of 74 consecutive patients with left-sided CRC presented with ACO who underwent self-expandable metallic stent (SEMS) placement followed by one-stage open (n = 58) or laparoscopic resection (n = 16) were evaluated retrospectively. The stent-laparoscopy group was also compared with a control group of 96 CRC patients who underwent regular laparoscopy without ACO between January 2010 and December 2011 to explore whether SEMS placement influenced the laparoscopic procedure or reduced long-term survival by influencing CRC oncological characteristics. The characteristics of patients among these groups were comparable. The rate of conversion to open surgery was 12.5% in the stent-laparoscopy group. Bowel function recovery and postoperative hospital stay were significantly shorter (3.3 ± 0.9 d vs 4.2 ± 1.5 d and 6.7 ± 1.1 d vs 9.5 ± 6.7 d, P = 0.016 and P = 0.005), and surgical time was significantly longer (152.1 ± 44.4 min vs 127.4 ± 38.4 min, P = 0.045) in the stent-laparoscopy group than in the stent-open group. Surgery-related complications and the rate of admission to the intensive care unit were lower in the stent-laparoscopy group. There were no significant differences in the interval between stenting and surgery, intraoperative blood loss, OS, and DFS between the two stent groups. Compared with those in the stent-laparoscopy group, all surgery-related parameters, complications, OS, and DFS in the control group were comparable. The stent-laparoscopy approach is a feasible, rapid, and minimally invasive option for patients with ACO caused by left-sided CRC and can achieve a favorable long-term prognosis.

  12. Use of Self-Expanding Metallic Ureteral Stents in the Secondary Treatment of Ureteral Stenosis Following Kidney Transplantation.

    Science.gov (United States)

    Xu, Guibin; Li, Xun; He, Yongzhong; Zhao, Haibo; Yang, Weiqing; Xie, Qingling

    2015-10-01

    To evaluate the safety and efficacy of self-expanding metal stents in the treatment of ureteral stenosis following kidney transplantation. Seven patients who developed benign stenosis after kidney transplantation were treated by a self-expanding metallic stent implantation from June 2007 to March 2014. All patients had undergone at least one open surgical procedure and one endourologic procedure for treatment of the stenosis. The extent of stenosis varied from 1.2 to 3.7 cm. Ultrasonography, urography, diuretic renography, and urine culture were performed every 3 months after stent insertion. Ureteroscopic examination was performed when needed. Stent placement was technically effective in all cases. The mean operative time was 37 minutes (range, 26-59 minutes). Lower urinary-tract symptoms and the ipsilateral flank pain were common early-stage complications and were greatly relieved after an average of 3 months. The mean follow-up duration was 38 months (range, 13-86 months), and no stent migration or fragmentation was observed. Urothelial hyperplasia occurred in only one patient and was effectively managed with a Double-J stent. Five patients had normal stable renal function; the remaining two had impaired renal function, including one patient with a preoperative renal failure who required dialysis at the end of the follow-up period (36 months). As an alternative to open surgery, implantation of a self-expanding metal stent is a safe and effective treatment for ureteral stenosis in patients who have undergone kidney transplantation.

  13. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of Medicine, Masan (Korea, Republic of)

    2008-06-15

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction.

  14. Self-expandable medical memorial metallic stent with 125I seeds for the treatment of esophageal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang Shuo; Lu Bin

    2011-01-01

    Objective: To discuss the curative effect and safety of the implantation of self-expandable medical memorial metallic stent with 125 I seeds for the treatment of advanced esophageal carcinomas. Methods: Implantation of self-expandable medical memorial metallic stent with 125 I seeds was performed in 32 patients with advanced esophageal canner. The clinical data were retrospectively analyzed. The technical success rate, the operation time, the immediate and mid-term effectiveness, the survival time, the complications, the body weight, the blood picture, the immune indexes, the average hospitalization days and hospitalization expenses were analyzed. Results: The average operation time was (18±5) minutes. Successful stent implantation was achieved in all 32 patients (100%). No 125 I seeds fell off during the procedure. The remission rate of dysphagia was 100%. Esophageal restenosis occurred in four patients, and displacement of the stent was seed in one patient. One month after the treatment, 90% of patients had a Karnofsky performance score over 60. The mean survival time was (8.7±6.6) months. The average hospitalization time was (7.8±3.7) days and the mean hospitalization cost was (12±3) thousand Chinese Yuan. Conclusion: For the treatment of esophageal carcinomas, the implantation of self-expandable medical memorial metallic stent with 125 I seeds is safe, effective and simple. This treatment can markedly improve the symptom of dysphagia and significantly prolong the patient's survival time. (authors)

  15. Self-expandable metal stents for malignant colonic obstruction: data from a retrospective regional SIED-AIGO study.

    Science.gov (United States)

    Di Mitri, Roberto; Mocciaro, Filippo; Traina, Mario; Montalbano, Luigi Maria; Familiari, Luigi; D'Amore, Fabio; Raimondo, Dario; Virgilio, Clara; Tarantino, Ilaria; Barresi, Luca; Giunta, Marco; Borina, Eleonora; Borruto, Antonino; Marino, Antonino

    2014-03-01

    Self-expandable metal stents are a non-surgical option for the treatment of symptomatic malignant colorectal obstruction as palliative treatment or as a bridge to surgery. To report data from a regional study on self-expandable metal stent (SEMS) placement for malignant colorectal obstruction. Two hundred and four patients (male 54.9%, mean age of 69.5 ± 14.2) were retrospectively evaluated and data on technical and clinical success, and complications, were analyzed. Technical and clinical success rates were 99% and 94.6% respectively, with 36.7% treated on an emergency basis and 63.3% electively. Palliative treatment was administered to 70.1%, and as a bridge to surgery for 29.9%. Complications were 17 neoplastic ingrowths, 10 stent migrations, and 4 perforations. Palliative treatment was associated with a higher risk of stent ingrowth (p=0.003), and chemotherapy with a lower risk of stent ingrowth (p=0.009). This regional study, although it has certain limitations, confirms the positive role of self-expandable metal stents in the treatment of symptomatic malignant colorectal obstruction, and that chemotherapy decreases the risk of ingrowth. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. Membranous obstruction of inferior vena cava(MOIVC): treatment with percutaneous transluminal angioplasty(PTA) and self expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Yeol; Kim, Baek Hyun; Cha, In Ho; Lee, Nam Joon; Kim, Yun Hwan; Kim, Jung Hyuk [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1994-03-15

    Percutaneous transluminal angioplasty(PTA) with a balloon catheter is a standard method of treatment for membranous obstruction of inferior vena cava(MOIVC). But, correct therapeutic approach has not been established for MOIVC patients whose lesion is associated with extensive thrombotic IVC occlusion. We tried to treat MOIVC associated with or without thrombus. We treated 13 cases of MOIVC(associated with thrombus in 7 cases, no thrombus in 6 cases) with PTA, thrombolysis and self-expandable metallic stents. PTA was successful in 8 cases, but failed in 5 cases. The recurred cases were retreated with PTA, but follow-up study revealed recoiling restenosis in 4 cases and intimal hyperplasia in 1 case at previous PTA site which could be overcome with a self-expandable metallic stent. The complication were occurred in 3 cases which were hemothorax, hemopericardium, and hemoperitoneum respectively. However, those were resolved by conservative treatment only. Recanalization and dilatation could be done in MOIVC patients with or without thrombosis for improvement of patient's symptom. Gianturco self-expandable metallic stent is useful in treatment of recurred MOIVC after balloon dilatation and preventing reocclusion of the IVC after PTA.

  17. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  18. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: a randomized prospective study.

    Science.gov (United States)

    Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon

    2014-07-01

    A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. Use of Self-Expanding Stents for the Treatment of Vertebral Artery Ostial Stenosis: a Single Center Experience

    International Nuclear Information System (INIS)

    Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2010-01-01

    To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval

  20. Outcome of self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer

    International Nuclear Information System (INIS)

    Jin Jing; Gao Li; Yu Zihao; Han Jianzhu; Zhai Renyou

    2007-01-01

    Objective: To retrospectively analyze the efficacy for self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer. Methods: From Jan 1996 to Sep 2002, 17 patients were treated with self-expanding metal stenting followed by Ir 192 high dose brachytherapy (brachytherapy group, n=5)and by external beam radiation therapy(external radiation therapy group, n=9). Brachytherapy was delivered on the same day or the following day after stenting with the total dose of DT 20- 30 Gy, twice daily, for 2-3 days. The median total dosage of external radiation therapy was 48 Gy (14-66 Gy), 2 Gy/fraction. Results: Jaundice was released after metal stenting from 71.4% to 14.3% (P=0.001), showing no significant difference between brachytherapy and external radiation therapy in terms of jaundice release(χ 2 =0.21, P=0.65). The median survival period(5-35 months)for whole groups was 12 months 1-, 2-year survival rates were 40.8% and 8.16%, respectively. No significant difference was shown for patients received either brachytherapy or external radiation therapy for 8 months, but with 1,2 year survival rate as 40.0%, 13.3%, respectively (χ 2 =1.10, P=0.29). Conclusions: Self-expanding metal stenting is able to release jaundice significantly and followed by high dose radiation therapy may further prolong the survival. (authors)

  1. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon; Ko, Ji Ho

    2008-01-01

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction

  2. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report

    Directory of Open Access Journals (Sweden)

    Kumagai Hozumi

    2012-09-01

    Full Text Available Abstract Introduction Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient’s general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  3. Dynamics and Physiological Roles of Stochastic Firing Patterns Near Bifurcation Points

    Science.gov (United States)

    Jia, Bing; Gu, Huaguang

    2017-06-01

    Different stochastic neural firing patterns or rhythms that appeared near polarization or depolarization resting states were observed in biological experiments on three nervous systems, and closely matched those simulated near bifurcation points between stable equilibrium point and limit cycle in a theoretical model with noise. The distinct dynamics of spike trains and interspike interval histogram (ISIH) of these stochastic rhythms were identified and found to build a relationship to the coexisting behaviors or fixed firing frequency of four different types of bifurcations. Furthermore, noise evokes coherence resonances near bifurcation points and plays important roles in enhancing information. The stochastic rhythms corresponding to Hopf bifurcation points with fixed firing frequency exhibited stronger coherence degree and a sharper peak in the power spectrum of the spike trains than those corresponding to saddle-node bifurcation points without fixed firing frequency. Moreover, the stochastic firing patterns changed to a depolarization resting state as the extracellular potassium concentration increased for the injured nerve fiber related to pathological pain or static blood pressure level increased for aortic depressor nerve fiber, and firing frequency decreased, which were different from the physiological viewpoint that firing frequency increased with increasing pressure level or potassium concentration. This shows that rhythms or firing patterns can reflect pressure or ion concentration information related to pathological pain information. Our results present the dynamics of stochastic firing patterns near bifurcation points, which are helpful for the identification of both dynamics and physiological roles of complex neural firing patterns or rhythms, and the roles of noise.

  4. Quantitative angiography methods for bifurcation lesions

    DEFF Research Database (Denmark)

    Collet, Carlos; Onuma, Yoshinobu; Cavalcante, Rafael

    2017-01-01

    Bifurcation lesions represent one of the most challenging lesion subsets in interventional cardiology. The European Bifurcation Club (EBC) is an academic consortium whose goal has been to assess and recommend the appropriate strategies to manage bifurcation lesions. The quantitative coronary...... angiography (QCA) methods for the evaluation of bifurcation lesions have been subject to extensive research. Single-vessel QCA has been shown to be inaccurate for the assessment of bifurcation lesion dimensions. For this reason, dedicated bifurcation software has been developed and validated. These software...

  5. Pierce instability and bifurcating equilibria

    International Nuclear Information System (INIS)

    Godfrey, B.B.

    1981-01-01

    The report investigates the connection between equilibrium bifurcations and occurrence of the Pierce instability. Electrons flowing from one ground plane to a second through an ion background possess a countable infinity of static equilibria, of which only one is uniform and force-free. Degeneracy of the uniform and simplest non-uniform equilibria at a certain ground plan separation marks the onset of the Pierce instability, based on a newly derived dispersion relation appropriate to all the equilibria. For large ground plane separations the uniform equilibrium is unstable and the non-uniform equilibrium is stable, the reverse of their stability properties at small separations. Onset of the Pierce instability at the first bifurcation of equilibria persists in more complicated geometries, providing a general criterion for marginal stability. It seems probable that bifurcation analysis can be a useful tool in the overall study of stable beam generation in diodes and transport in finite cavities

  6. Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jinhe [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Teng Gaojun [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)]. E-mail: gjteng@vip.sina.com; Zhu Guangyu [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Shicheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Deng Gang [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Jie [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)

    2007-02-15

    Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal segment in all rabbits. Neither {sup 125}I seeds dislodged from the stent during the deployment, nor they did during the follow-up period. The greatest (16.2 Gy) absorbed dose was found in the tissue 10 mm from {sup 125}I seeds at 8 weeks. Slight epithelial hyperplasia on the stent surface and submucosal inflammatory process developed at 2 weeks, which reached the peak at 8 weeks after the procedure. Significant thickness of the esophageal muscular layer was found at 8 weeks only in the groups with {sup 125}I seeds. On radiologic follow-up, moderate strictures on both ends of the stents developed at 4 weeks and became severe at 8 weeks after the procedure in all groups. Conclusion: Deployment of a self-expandable stent loaded with {sup 125}I seeds is technically feasible and safe within the first 8 weeks. Acute and subacute radiotolerance of the treated esophagus and its adjacent tissues by {sup 125}I seeds is well preserved in a healthy rabbit model.

  7. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Pausawasadi, Nonthalee [Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok (Thailand); Soontornmanokul, Tanassanee; Rerknimitr, Rungsun [Department of Medicine, Chulalongkorn University, Bangkok (Thailand)

    2012-02-15

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  8. Self-expanding nanoplatinum-coated nitinol devices for atrial septal defect and patent ductus arteriosus closure: a swine model.

    Science.gov (United States)

    Lertsapcharoen, Pornthep; Khongphatthanayothin, Apichai; La-orkhun, Vidhavas; Supachokchaiwattana, Pentip; Charoonrut, Phingphol

    2006-01-01

    Our purpose was to evaluate self-expanding nanoplatinum-coated nitinol devices for transcatheter closure of atrial septal defects and patent ductus arteriosus in a swine model. The devices were braided from platinum-activated nitinol wires and filled with polyester to enhance thrombogenicity. The platinum activation of the nitinol wires was carried out with the help of Nanofusion technology. The coating of platinum covers the exposed surface of the nitinol wires and prevents the release of nickel into the blood stream after the implantation of the device but does not affect its shape memory, which makes the device self-expanding after it is loaded from the catheter. Atrial septal defects were created in 12 piglets by balloon dilation of the patent foramen ovale. The size of the device was selected on the basis of the diameter of the balloon and the size of the defect, measured by transthoracic echocardiography. The devices were successfully deployed in all 12 piglets under fluoroscopic study. Transthoracic color Doppler echocardiograms showed complete closure of the atrial septal defect within 15 minutes of device implantation. Twelve patent ductus arteriosus closure devices were deployed in the right or left subclavian arteries in 10 piglets. Angiograms showed complete occlusion of the subclavian arteries within a few minutes of device deployment. In the atrial septal defect cases, the autopsy findings showed complete organizing fibrin thrombus formation and complete neo-endothelialization on the outer surface of the devices within one week and six weeks of implantation, respectively. The use of self-expanding nanoplatinum-coated nitinol devices for the transcatheter closure of atrial septal defects and patent ductus arteriosus is feasible. The excellent occlusion result and complete neo-endothelialization of the devices in the swine model is an indication of the potential of these devices in human application.

  9. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    International Nuclear Information System (INIS)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee; Rerknimitr, Rungsun

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  10. Efficacy of a Self-Expandable Porous Stent as the Sole Curative Treatment for Extracranial Carotid Pseudoaneurysms.

    Science.gov (United States)

    Chen, Peng Roc; Edwards, Nancy J; Sanzgiri, Aditya; Day, Arthur L

    2016-04-01

    Extracranial carotid pseudoaneurysms are uncommon vascular lesions. Even with conservative management complications can happen, such as delayed cerebral embolization or symptoms due to flow limitation. Although endovascular therapy can be curative, literature demonstrating a preferred technique is scant. Our goal was to evaluate the use of 1 technique only-the deployment of overlapping self-expandable porous stents-to treat a series of extracranial carotid pseudoaneurysms. From 2008 to 2014, 14 consecutive cases of symptomatic extracranial carotid pseudoaneurysms were managed with single or multilayer porous stents at our institution. Each patient underwent a standardized angiographic follow-up at 6 months. Twelve patients also received a follow-up computed tomography angiogram at 12 months, and yearly thereafter (median radiographic follow-up, 38 months). The total clinical follow-up period ranged between 6 and 69 months (median, 46 months). In our series, each of the extracranial carotid pseudoaneurysms appeared to be the result of carotid artery dissection with associated carotid stenosis at the origin of every pseudoaneurysm. Endovascular treatment consisted of 1-3 layers of self-expandable porous stents placed without balloon angioplasty. Immediately after stenting angiographic images were notable for stagnant opacification of the pseudoaneurysm through the stent(s). All pseudoaneurysms were completely obliterated by the 6-month follow-up angiogram and remained so throughout the radiographic follow-up period. Complications were minimal, consisting of 1 patient developing a mild Horner's syndrome after treatment that resolved during clinical follow-up. Extracranial carotid pseudoaneurysms can be successfully obliterated with the use of porous, self-expandable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Science.gov (United States)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks. PMID:22563290

  12. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  13. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  14. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  15. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign

  16. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and

  17. "Stent" auto-expansível nas dissecções da aorta tipo B Self-expanding stent in type B dissections of the aorta

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    1999-07-01

    Full Text Available O tratamento clínico das dissecções agudas da aorta do tipo B tem mortalidade em torno de 25% menor que a mortalidade cirúrgica. O tratamento cirúrgico das dissecções crônicas também produz uma morbidade e mortalidade elevadas. A utilização de "stents"auto-expansíveis endovasculares pode ser uma nova alternativa no tratamento destas lesões. De abril a dezembro de 1998 foram implantados 15 "stents" endovasculares, 10 em dissecções agudas e 5 em crônicas. A idade dos pacientes variou entre 48 e 75 anos (média=60,53±9,73 anos com 66,6% do sexo masculino. Os pacientes foram submetidos à esternotomia mediana, circulação extracorpórea (CEC com hipotermia profunda (18° - 20°C, parada circulatória total (PCT e perfusão cerebral retrógrada (PCR. A aorta transversa foi incisada e implantado o "stent" na aorta descendente sob auxílio de aortoscopia. Foram analisados os tempos de CEC, pinçamento aórtico, PCT, PCR, reaquecimento, ventilação mecânica, internação, sangramento trans e pós-operatório, reposição sangüínea, gasometria, curva de eventos e sobrevida. A mortalidade hospitalar (30 dias foi de 6,6%; 2 pacientes foram reoperados com 3 e 6 meses após a operação com dissecção da aorta ascendente e aneurisma roto distal ao "stent". Quatorze vêm sendo acompanhados com 1 a 8m de evolução, sendo que 85,7% estão livres de eventos e curva de sobrevida de 93,1%(240 dias. Concluímos que o implante de "stent"intraluminais auto-expansíveis apresentou mortalidade menor na fase aguda da doença (6,6% comparada à nossa experiência anterior com o tratamento clínico (30%. Apesar da amostra ser pequena, o procedimento parece ser promissor e necessita mais acompanhamento.The clinical treatment of acute type B aortic dissection has a mortality of about 25%, therefore, less than surgical mortality. The surgical treatment of chronic dissections also produces a high morbidity and mortality. The use of self-expanding

  18. Homoclinic bifurcation in Chua's circuit

    Indian Academy of Sciences (India)

    spiking and bursting behaviors of neurons. Recent experiments ... a limit cycle increases in a wiggle with alternate sequences of stable and unstable orbits via ... further changes in parameter, the system shows period-adding bifurcation when .... [21–23] transition from limit cycle to single scroll chaos via PD and then to alter-.

  19. Bifurcation scenarios for bubbling transition.

    Science.gov (United States)

    Zimin, Aleksey V; Hunt, Brian R; Ott, Edward

    2003-01-01

    Dynamical systems with chaos on an invariant submanifold can exhibit a type of behavior called bubbling, whereby a small random or fixed perturbation to the system induces intermittent bursting. The bifurcation to bubbling occurs when a periodic orbit embedded in the chaotic attractor in the invariant manifold becomes unstable to perturbations transverse to the invariant manifold. Generically the periodic orbit can become transversely unstable through a pitchfork, transcritical, period-doubling, or Hopf bifurcation. In this paper a unified treatment of the four types of bubbling bifurcation is presented. Conditions are obtained determining whether the transition to bubbling is soft or hard; that is, whether the maximum burst amplitude varies continuously or discontinuously with variation of the parameter through its critical value. For soft bubbling transitions, the scaling of the maximum burst amplitude with the parameter is derived. For both hard and soft transitions the scaling of the average interburst time with the bifurcation parameter is deduced. Both random (noise) and fixed (mismatch) perturbations are considered. Results of numerical experiments testing our theoretical predictions are presented.

  20. Bifurcation of steady tearing states

    International Nuclear Information System (INIS)

    Saramito, B.; Maschke, E.K.

    1985-10-01

    We apply the bifurcation theory for compact operators to the problem of the nonlinear solutions of the 3-dimensional incompressible visco-resistive MHD equations. For the plane plasma slab model we compute branches of nonlinear tearing modes, which are stationary for the range of parameters investigated up to now

  1. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  2. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H. [Robert Janker Klinik, Bonn (Germany); Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany); Miloslavski, E.; Lowens, S.; Reinartz, J. [Robert Janker Klinik, Bonn (Germany); Liebig, T.; Kuehne, D. [Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany)

    2005-03-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  3. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  4. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    International Nuclear Information System (INIS)

    Henkes, H.; Miloslavski, E.; Lowens, S.; Reinartz, J.; Liebig, T.; Kuehne, D.

    2005-01-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  5. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.

    Science.gov (United States)

    Mukai, Tsuyoshi; Yasuda, Ichiro; Isayama, Hiroyuki; Iwashita, Takuji; Itoi, Takao; Kawakami, Hiroshi; Kogure, Hirofumi; Nakai, Yousuke

    2016-09-01

    In patients with unresectable malignant distal biliary obstruction, covered self-expandable metallic stents (CSEMS) may remain patent longer than uncovered self-expandable metallic stents as a result of tumor ingrowth prevention. One main cause of recurrent biliary obstruction (RBO) in CSEMS is sludge formation, which can be prevented using a large-bore stent. Therefore, we developed a novel, 12-mm diameter fully covered SEMS (FCSEMS) and investigated its clinical safety, efficacy, and rate of adverse events. This prospective, multicenter pilot study, which ran between June 2011 and November 2012, included 38 consecutive patients with unresectable malignant distal biliary obstruction. All patients underwent endoscopic insertion of our novel stent. Primary endpoint was non-RBO rate 6 months after placement. Technical and functional success rates of the procedures were 100%. Six-month non-RBO rate was 50%, and median time to RBO was 184 days. Median survival time was 241 days. Twelve patients died within 6 months after stent placement without RBO. RBO was observed in 10 patients (26%), with seven experiencing stent occlusion and three experiencing stent migration. Adverse events other than RBO (at Stent removal for reintervention was successfully completed in eight patients. Our novel FCSEMS may be safe and effective for managing malignant distal obstruction with an acceptable incidence of adverse events. © 2016 Japan Gastroenterological Endoscopy Society.

  6. [Cost-effectiveness trial of self-expandable metal stents and plastic biliary stents in malignant biliary obstruction].

    Science.gov (United States)

    Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán

    2016-02-14

    Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.

  7. Bifurcation in a buoyant horizontal laminar jet

    Science.gov (United States)

    Arakeri, Jaywant H.; Das, Debopam; Srinivasan, J.

    2000-06-01

    The trajectory of a laminar buoyant jet discharged horizontally has been studied. The experimental observations were based on the injection of pure water into a brine solution. Under certain conditions the jet has been found to undergo bifurcation. The bifurcation of the jet occurs in a limited domain of Grashof number and Reynolds number. The regions in which the bifurcation occurs has been mapped in the Reynolds number Grashof number plane. There are three regions where bifurcation does not occur. The various mechanisms that prevent bifurcation have been proposed.

  8. Self-expandable covered metallic esophageal stent impregnated with beta-emitting radionuclide: an experimental study in canine esophagus

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Doo; Wang, Hee Jung; Kim, Gui-Eon; Kim, Bong Wan; Yim, Hyunee; Han, Sang Keon; Park, Chan H.; Joh, Chul Woo; Kim, Kyung-Hwa; Park, Kyung Bae; Shin, Kyong-Min

    2002-01-01

    Purpose: A specially designed self-expandable covered metallic stent impregnated with the β-emitting radioisotope 166 Ho ( 166 Ho, energy: 1.85 and 1.76 MeV, T((1)/(2)): 26.8 h) was developed at our institute for the purpose of intraluminal palliative brachytherapy, as well as for treating malignant esophageal stricture and swallowing difficulty. The aim of this study was to evaluate the tissue response to brachytherapy and the safety of the radioactive metallic stent with regard to the normal canine esophagus before clinical application. Methods and Materials: 166 Ho was impregnated into the polyurethane membrane (50 μ thickness) covering the outer surface of a self-expandable metallic stent (diameter, 18 mm; length, 40 mm). Stents with radioactivity 4.0-7.8 mCi (Group A, n=15), 1.0-1.8 mCi (Group B, n 5), and 0.5-0.7 mCi (Group C, n=5) were placed in the esophagi of 25 healthy beagle dogs, and the stents were tightly anchored surgically to prevent migration. The estimated radiation dose calculated by Monte Carlo simulation was 194-383 Gy in Group A, 48-90 Gy in Group B, and 23-32 Gy in Group C. The dogs were killed 8-12 weeks after insertion of the stents, and histologic examinations of the esophageal walls were performed. Results: In Group A, 3 of 15 dogs died of wound infection, so specimens were obtained from only 12 dogs; all 12 cases showed esophageal stricture with mucosal ulceration. Microscopically, severe fibrosis and degeneration of the muscular propria were found in 3 dogs, complete fibrosis of the entire esophageal wall was found in 7 dogs, and esophageal fibrosis with radiation damage within periesophageal soft tissue was found in 2 dogs. However, esophageal perforation did not develop, despite extremely high radiation doses. In Group B, glandular atrophy and submucosal fibrosis were found, but the muscular layer was intact. In Group C, no histologic change was found in 3 dogs, but submucosal inflammation and glandular atrophy with intact mucosa

  9. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  10. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  11. Implantation of modified Y-shaped self-expandable stent for the treatment of stenosis of gastroenteric stoma: preliminary results in five cases

    International Nuclear Information System (INIS)

    Wu Gang; Si Jiangtao; Han Xinwei; Jiao Dechao; Ding Pengxu; Fu Mingti; Li Zhen; Ma Ji

    2010-01-01

    Objective To investigate the feasibility and therapeutic effect of stenting therapy by using modified Y-shaped self-expandable metal stent for the stenosis of gastroenteric stoma. Methods: According to the particular anatomic structures and the pathological features of the narrowed gastroenteric stoma,the authors designed a modified Y-shaped self-expandable metal stent. Under the fluoroscopic guidance, implantation of modified Y-shaped self-expandable metal stent was performed in 5 patients with narrowed gastroenteric stoma. The technical safety and the clinical results were evaluated. Results: The modified Y-shaped self-expandable metal stent was successfully implanted with one procedure in all five patients. After the implantation the symptoms such as nausea, vomiting, abdominal distension were promptly relieved, and the patients' living quality was markedly improved. Conclusion: The stenting therapy with modified Y-shaped self-expandable metal stent can rapidly relieve the stenosis of gastroenteric stoma once for all. The technique is feasible and the short-term effect is reliable, therefore, it is worth popularizing this therapy in clinical practice. (authors)

  12. Self-expandable metal stent placement in a child for treatment of achalasia after failed Heller myotomy.

    Science.gov (United States)

    Gugig, Roberto; Muñoz Jurado, Guillermo; Huang, Clifton; Oleas, Roberto; Robles-Medranda, Carlos

    2018-01-01

    Background and study aims  Childhood achalasia treatment remains inconclusive. What is next after myotomy failure? Repeated pneumatic-dilation put patients at greater risk of perforation with possible symptom recurrence. We report on a 12-year-old patient with a 1-year history of achalasia whom underwent Heller myotomy with fundoplication and recurred with symptoms 1 week after surgery. Pneumatic dilatation was considered but not done because of the risk of esophageal perforation. The decision was made to place a fully covered self-expanding metallic stent (FC-SEMS) for 3 months, which resolved the stenosis as confirmed by esophagram. The patient has remained asymptomatic since the procedure was performed 2 years ago. FC-SEMS is an alternative for treatment of refractory achalasia in children who do not respond to conventional treatment.

  13. Treatment of Esophageal Variceal Hemorrhage with Self-Expanding Metal Stents as a Rescue Maneuver in a Swiss Multicentric Cohort

    Directory of Open Access Journals (Sweden)

    Fabienne C. Fierz

    2013-03-01

    Full Text Available Acute esophageal variceal bleeding in patients with portal hypertension remains a complication with a high mortality today. In cases refractory to standard therapy including endoscopic band ligation and pharmacological therapy, traditionally balloon tamponade has been used as salvage therapy. However, these techniques show several important limitations. Self-expanding metal stents (SEMS have been proposed as an alternative rescue treatment. The use of variceal stenting in 7 patients with a total of 9 bleeding episodes in three different Swiss hospitals is demonstrated. While immediate bleeding control is achieved in a high percentage of cases, the 5-day and 6-week mortality rate remain high. Mortality is strongly influenced by the severity of the underlying liver disease. Accordingly, our data represent a high-risk patient collective. Thanks to their safety and easy handling, SEMS are an interesting alternative to balloon tamponade as a bridging intervention to definitive therapy including the pre-hospital setting.

  14. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive...... condition. Three days after stent deployment, x-ray examinations revealed a small-bowel obstruction and emergency surgery was performed. Intraoperative findings demonstrated a segment of ileum fixated to the tumor in the small pelvis, resulting in the obstructive condition. Furthermore, a cecal perforation...

  15. Biliary self-expandable metallic stent using single balloon enteroscopy assisted ERCP: overcoming limitations of current accessories

    Directory of Open Access Journals (Sweden)

    Rolando Pinho

    2013-10-01

    Full Text Available Device assisted enteroscopy (DAE techniques have been recently developed for the diagnosis and treatment of small bowel diseases. These techniques can also be used to perform endoscopic retrograde cholangiopancreatography (ERCP in patients with surgically altered anatomies. The main difficulties with DAE-ERCP are related to type of surgery, to the different dimensions and lack of frontal view of the enteroscope and to the resulting limitations with the use of standard accessories, resulting in the need of dedicated accessory devices. Although most ERCP techniques have been successfully performed with DAE-ERCP, biliary self-expandable metallic stents (SEMS have not yet been used, as dedicated biliary SEMS for the enteroscope are lacking. The authors present a case report showing a new method to place standard biliary trough-the-scope SEMS with DAE-ERCP, using a different technique of stent deployment.

  16. An Efficient Finite Element Framework to Assess Flexibility Performances of SMA Self-Expandable Carotid Artery Stents

    Directory of Open Access Journals (Sweden)

    Mauro Ferraro

    2015-07-01

    Full Text Available Computer-based simulations are nowadays widely exploited for the prediction of the mechanical behavior of different biomedical devices. In this aspect, structural finite element analyses (FEA are currently the preferred computational tool to evaluate the stent response under bending. This work aims at developing a computational framework based on linear and higher order FEA to evaluate the flexibility of self-expandable carotid artery stents. In particular, numerical simulations involving large deformations and inelastic shape memory alloy constitutive modeling are performed, and the results suggest that the employment of higher order FEA allows accurately representing the computational domain and getting a better approximation of the solution with a widely-reduced number of degrees of freedom with respect to linear FEA. Moreover, when buckling phenomena occur, higher order FEA presents a superior capability of reproducing the nonlinear local effects related to buckling phenomena.

  17. Bifurcation routes and economic stability

    Czech Academy of Sciences Publication Activity Database

    Vošvrda, Miloslav

    2001-01-01

    Roč. 8, č. 14 (2001), s. 43-59 ISSN 1212-074X R&D Projects: GA ČR GA402/00/0439; GA ČR GA402/01/0034; GA ČR GA402/01/0539 Institutional research plan: AV0Z1075907 Keywords : macroeconomic stability * foreign investment phenomenon * the Hopf bifurcation Subject RIV: AH - Economics

  18. Bifurcations of Fibonacci generating functions

    Energy Technology Data Exchange (ETDEWEB)

    Ozer, Mehmet [Istanbul Kultur University, E5 Karayolu Uzeri Sirinevler, 34191 Istanbul (Turkey) and Semiconductor Physics Institute, LT-01108 and Vilnius Gediminas Technical University, Sauletekio 11, LT-10223 (Lithuania)]. E-mail: m.ozer@iku.edu.tr; Cenys, Antanas [Semiconductor Physics Institute, LT-01108 and Vilnius Gediminas Technical University, Sauletekio 11, LT-10223 (Lithuania); Polatoglu, Yasar [Istanbul Kultur University, E5 Karayolu Uzeri Sirinevler, 34191 Istanbul (Turkey); Hacibekiroglu, Guersel [Istanbul Kultur University, E5 Karayolu Uzeri Sirinevler, 34191 Istanbul (Turkey); Akat, Ercument [Yeditepe University, 26 Agustos Campus Kayisdagi Street, Kayisdagi 81120, Istanbul (Turkey); Valaristos, A. [Aristotle University of Thessaloniki, GR-54124, Thessaloniki (Greece); Anagnostopoulos, A.N. [Aristotle University of Thessaloniki, GR-54124, Thessaloniki (Greece)

    2007-08-15

    In this work the dynamic behaviour of the one-dimensional family of maps F{sub p,q}(x) = 1/(1 - px - qx {sup 2}) is examined, for specific values of the control parameters p and q. Lyapunov exponents and bifurcation diagrams are numerically calculated. Consequently, a transition from periodic to chaotic regions is observed at values of p and q, where the related maps correspond to Fibonacci generating functions associated with the golden-, the silver- and the bronze mean.

  19. Bifurcations of Fibonacci generating functions

    International Nuclear Information System (INIS)

    Ozer, Mehmet; Cenys, Antanas; Polatoglu, Yasar; Hacibekiroglu, Guersel; Akat, Ercument; Valaristos, A.; Anagnostopoulos, A.N.

    2007-01-01

    In this work the dynamic behaviour of the one-dimensional family of maps F p,q (x) = 1/(1 - px - qx 2 ) is examined, for specific values of the control parameters p and q. Lyapunov exponents and bifurcation diagrams are numerically calculated. Consequently, a transition from periodic to chaotic regions is observed at values of p and q, where the related maps correspond to Fibonacci generating functions associated with the golden-, the silver- and the bronze mean

  20. Utilization of self-expanding stents in the treatment of intracranial atherosclerotic disease in the distal small cerebral vessels

    International Nuclear Information System (INIS)

    Turk, Aquilla S.; Niemann, David B.; Aagaard-Kienitz, Beverly; Ahmed, Azam; Brooks, Nathaniel; Levine, Ross L.

    2007-01-01

    Previously, endovascular treatment of stenosis related to intracranial atherosclerosis (ICAD) involving arteries measuring less than 2 mm in diameter was limited. To our knowledge, there are no reports in the literature addressing stent placement for treatment of stenosis in arteries of this size. Four patients aged 33 to 80 years (mean 57.5 years) with medically refractory ICAD underwent angioplasty and stenting of small (<2 mm) distal intracerebral arteries. Vessel location and length of follow-up were anterior cerebral artery (ACA) A1 segment (5 months), ACA A2 segment (18 months), middle cerebral artery M1 segment (18 months), and posterior cerebral artery P1 segment (8 months) with vessel calibers ranging from 1.2 to 1.8 mm. Clinical and imaging follow-up ranged from 5 to 18 months. All procedures were successfully performed without complications. Follow-up out to 18 months demonstrated one vessel that went on to occlusion while the other stented vessel segments remained patent. One patient died 8 months after stenting, but the death was not related to neurological disease. The remaining patients experienced resolution of the presenting symptomatology and remained asymptomatic throughout follow-up. In this small series, stenoses of distal (<2 mm) cerebral arteries were amenable to treatment using new self-expanding stents. We safely and successfully treated four arteries smaller than 2 mm in diameter with newer self-expanding stents. All patients remained clinically asymptomatic. One stent occluded at 5 months and the others remained patent during follow-up. Longer term clinical follow-up is required to determine the durability and viability of this therapy. (orig.)

  1. Outcomes of secondary self-expandable metal stents versus surgery after delayed initial palliative stent failure in malignant colorectal obstruction.

    Science.gov (United States)

    Yoon, Jin Young; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2013-01-01

    When re-intervention is required due to an occluded first colorectal self-expanding metal stent for malignant colorectal obstruction, serious controversies exist regarding whether to use endoscopic re-stenting or surgery. To compare the clinical outcomes in patients who underwent stent re-insertion versus palliative surgery as a second intervention. A total of 115 patients who received either self-expandable metal stent (SEMS) insertion or palliative surgery for treatment of a second occurrence of malignant colorectal obstruction after the first SEMS placement were retrospectively studied between July 2005 and December 2009. The median overall survival (8.2 vs. 15.5 months) and progression-free survival (4.0 vs. 2.7 months) were not significantly different between the stent and surgery groups (p = 0.895 and 0.650, respectively). The median lumen patency in the stent group was 3.4 months and that in the surgery group was 7.9 months (p = 0.003). The immediate complication rate after second stent insertion was 13.9% and late complication rate was observed in 12 of 79 (15.2%) patients. There was no mortality related to the SEMS procedure. The complication and mortality rates associated with palliative surgery were 3.5% (2/57) and 12.3% (7/57), respectively. Although there is no significant difference in the overall survival between stenting and surgery, a secondary stent insertion had a lower mortality rate despite a shorter duration of temporary colorectal decompression compared to that of palliative surgery.

  2. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  3. Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation

    International Nuclear Information System (INIS)

    Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin

    2012-01-01

    Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)

  4. Resonant Homoclinic Flips Bifurcation in Principal Eigendirections

    Directory of Open Access Journals (Sweden)

    Tiansi Zhang

    2013-01-01

    Full Text Available A codimension-4 homoclinic bifurcation with one orbit flip and one inclination flip at principal eigenvalue direction resonance is considered. By introducing a local active coordinate system in some small neighborhood of homoclinic orbit, we get the Poincaré return map and the bifurcation equation. A detailed investigation produces the number and the existence of 1-homoclinic orbit, 1-periodic orbit, and double 1-periodic orbits. We also locate their bifurcation surfaces in certain regions.

  5. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    International Nuclear Information System (INIS)

    Chen, I-Ming; Chen, Po-Lin; Huang, Chun-Yang; Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che

    2017-01-01

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  6. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  7. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis.

    Science.gov (United States)

    Li, Jinjin; Li, Tong; Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19-4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05-10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57-1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94-1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56-0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12-0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03-3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54-34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36-4.50; p = 0.003, I2 = 0%). Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary

  8. Self-Expandable Metal Stents for Persisting Esophageal Variceal Bleeding after Band Ligation or Injection-Therapy: A Retrospective Study.

    Directory of Open Access Journals (Sweden)

    Martin Müller

    Full Text Available Despite a pronounced reduction of lethality rates due to upper gastrointestinal bleeding, esophageal variceal bleeding remains a challenge for the endoscopist and still accounts for a mortality rate of up to 40% within the first 6 weeks. A relevant proportion of patients with esophageal variceal bleeding remains refractory to standard therapy, thus making a call for additional tools to achieve hemostasis. Self-expandable metal stents (SEMS incorporate such a tool.We evaluated a total number of 582 patients admitted to our endoscopy unit with the diagnosis "gastrointestinal bleeding" according to our documentation software between 2011 and 2014. 82 patients suffered from esophageal variceal bleeding, out of which 11 cases were refractory to standard therapy leading to SEMS application. Patients with esophageal malignancy, fistula, or stricture and a non-esophageal variceal bleeding source were excluded from the analysis. A retrospective analysis reporting a series of clinically relevant parameters in combination with bleeding control rates and adverse events was performed.The initial bleeding control rate after SEMS application was 100%. Despite this success, we observed a 27% mortality rate within the first 42 days. All of these patients died due to non-directly hemorrhage-associated reasons. The majority of patients exhibited an extensive demand of medical care with prolonged hospital stay. Common complications were hepatic decompensation, pulmonary infection and decline of renal function. Interestingly, we found in 7 out of 11 patients (63.6% stent dislocation at time of control endoscopy 24 h after hemostasis or at time of stent removal. The presence of hiatal hernia did not affect obviously stent dislocation rates. Refractory patients had significantly longer hospitalization times compared to non-refractory patients.Self-expandable metal stents for esophageal variceal bleeding seem to be safe and efficient after failed standard therapy

  9. Removable fully covered self-expandable metal stents in the treatment of common bile duct strictures due to chronic pancreatitis: a case series

    NARCIS (Netherlands)

    Cahen, D. L.; Rauws, E. A.; Gouma, D. J.; Fockens, P.; Bruno, M. J.

    2008-01-01

    The aim of this study was to test the removability of fully covered self-expandable metal stents (FCSEMS) in patients with a benign common bile duct (CBD) stricture. A FCSEMS was inserted in six patients with a CBD stricture due to chronic pancreatitis who were considered to be unfit for surgery,

  10. Chemotherapy versus self-expanding metal stent as primary treatment of severe dysphagia from unresectable oesophageal or gastro-oesophageal junction cancer.

    Science.gov (United States)

    Touchefeu, Yann; Archambeaud, Isabelle; Landi, Bruno; Lièvre, Astrid; Lepère, Céline; Rougier, Philippe; Mitry, Emmanuel

    2014-03-01

    To compare chemotherapy first (group 1) versus self-expanding metal stent first (group 2) for the management of malignant dysphagia in unresectable oesophageal or gastro-oesophageal junction cancer. Patients from two university hospitals with severe malignant dysphagia (dysphagia score ≥ 2) uneligible for surgery or radiochemotherapy were evaluated retrospectively. Forty-two patients were included in group 1, and 29 in group 2. After 4 weeks, dysphagia scores improved by at least 1 point in 67% of patients in group 1 versus 93% in group 2 (p=0.01); 48% of patients in group 1 were able to eat solid food versus 68% in group 2 (p=0.054). In group 1, a self-expanding metal stent was secondarily placed in 18 patients (42.9%), whereas in group 2 dysphagia required a second self-expanding metal stent placement in 33.3% of patients. Chemotherapy as the first treatment may be a valid option, avoiding self-expanding metal stent insertion in half of the patients. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Insertion of a self-expandable endotracheal metal stent using topical anaesthesia and a fibreoptic bronchoscope: a comfortable way to offer palliation.

    OpenAIRE

    Coolen, D.; Slabbynck, H.; Galdermans, D.; Van Schaardenburg, C.; Mortelmans, L. L.

    1994-01-01

    A self-expandable stent was used to obtain prolonged relief of stridor resulting from tracheal obstruction by extrinsic tumour compression despite prior external irradiation. The stent was inserted in an easy and comfortable procedure with fibreoptic bronchoscopy under local anaesthesia.

  12. Safety and efficacy of a fully covered large-diameter self-expanding metal stent for the treatment of upper gastrointestinal perforations, anastomotic leaks, and fistula

    NARCIS (Netherlands)

    van den Berg, M. W.; Kerbert, A. C.; van Soest, E. J.; Schwartz, M. P.; Bakker, C. M.; Gilissen, L. P. L.; van Hooft, J. E.

    2016-01-01

    Upper gastrointestinal perforations, fistula, and anastomotic leaks are severe conditions with high mortality. Temporary endoscopic placement of fully covered self-expanding metal stent (fSEMS) has emerged as treatment option. Stent migration is a major drawback of currently used stents. Migration

  13. Differences in Endothelial Injury After Balloon Angioplasty, Insertion of Balloon-Expanded Stents or Release of Self-Expanding Stents: An Electron Microscopic Experimental Study

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Carlemalm, Erik; Cwikiel, Wojciech

    1999-01-01

    Purpose: To evaluate which of six different commonly available stents inserted into an artery without percutaneous transluminal angioplasty (PTA) causes the least endothelial damage. To compare the degree of endothelial injury after insertion of such a stent with injury caused by PTA. Methods: Twelve healthy pigs were used in the experiments. In the first part of the study six different types of stents were inserted into the common iliac arteries. In the second part of the study self-expanding stents with large spaces between the wires were used. PTA was performed in the contralateral iliac artery. The pigs were killed immediately after the procedure and resected specimens examined after fixation, using scanning electron microscopy. Results: All procedures but two were accomplished successfully. More endothelium was preserved after insertion of self-expanding stents with large spaces between the wires, compared with stents with small spaces and balloon-expanded stents. After insertion of self-expanding stents with large spaces, 50.1% ± 16.4% of the endothelium remained intact, compared with only 5.6% ± 7.7% after PTA. The difference was statistically significant (p < 0.001). Conclusion: Self-expanding stents with large spaces between the wires, inserted without PTA, cause less damage to the endothelium than other stents and significantly less damage than PTA

  14. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  15. Study of the Behavior of a Bell-Shaped Colonic Self-Expandable NiTi Stent under Peristaltic Movements

    Directory of Open Access Journals (Sweden)

    Sergio Puértolas

    2013-01-01

    Full Text Available Managing bowel obstruction produced by colon cancer requires an emergency intervention to patients usually in poor conditions, and it requires creating an intestinal stoma in most cases. Regardless of that the tumor may be resectable, a two-stage surgery is mandatory. To avoid these disadvantages, endoscopic placement of self-expanding stents has been introduced more than 10 years ago, as an alternative to relieve colonic obstruction. It can be used as a bridge to elective single-stage surgery avoiding a stoma or as a definitive palliative solution in patients with irresectable tumor or poor estimated survival. Stents must be capable of exerting an adequate radial pressure on the stenosed wall, keeping in mind that stent must not move or be crushed, guaranteeing an adequate lumen when affected by peristaltic waves. A finite element simulation of bell-shaped nitinol stent functionality has been done. Catheter introduction, releasing at position, and the effect of peristaltic wave were simulated. To check the reliability of the simulation, a clinical experimentation with porcine specimens was carried out. The stent presented a good deployment and flexibility. Stent behavior was excellent, expanding from the very narrow lumen corresponding to the maximum peristaltic pressure to the complete recovery of operative lumen when the pressure disappears.

  16. Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats

    Directory of Open Access Journals (Sweden)

    Olavo Ribeiro Rodrigues

    2013-01-01

    Full Text Available PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.

  17. Self-expandable metal stents for malignant esophageal obstruction: a comparative study between extrinsic and intrinsic compression.

    Science.gov (United States)

    Rhee, K; Kim, J-H; Jung, D H; Han, J W; Lee, Y C; Lee, S K; Shin, S K; Park, J C; Chung, H S; Park, J J; Youn, Y H; Park, H

    2016-04-01

    Self-expandable metal stents (SEMSs) are effective for malignant esophageal obstruction, but usefulness of SEMSs in extrinsic lesions is yet to be elucidated. This study is aimed at evaluating the clinical usefulness of SEMSs in the extrinsic compression compared with intrinsic. A retrospective review was conducted for 105 patients (intrinsic, 85; extrinsic, 20) with malignant esophageal obstruction who underwent endoscopic SEMSs placement. Technical and clinical success rates were evaluated and clinical outcomes were compared between extrinsic and intrinsic group. Extrinsic group was mostly pulmonary origin. Overall technical and clinical success rate was 100% and 91%, respectively, without immediate complications. Extrinsic and intrinsic group did not differ significantly in clinical success rate. The median stent patency time was 131.3 ± 85.8 days in intrinsic group while that of extrinsic was 54.6 ± 45.1 due to shorter survival after stent insertion. The 4-, 8-, and 12-week patency rates were 90.5%, 78.8%, and 64.9% respectively in intrinsic group, while stents of extrinsic group remained patent until death. Uncovered, fully covered, and double-layered stent were used evenly and the types did not influence patency in both groups. In conclusion, esophageal SEMSs can safely and effectively be used for malignant extrinsic compression as well as intrinsic. © 2015 International Society for Diseases of the Esophagus.

  18. Self-expanding metal mesh stents and laser therapy: a complementary approach for the palliation of malignant dysphagia

    Science.gov (United States)

    Madhotra, Ravi; Raouf, A.; Sturgess, R.; Krasner, Neville

    1997-12-01

    Re-establishment of the oesophageal lumen is the main focus of care in patients with inoperable oesophageal carcinomas. The self-expanding metal mesh stents (MMS) are increasingly being used. 51 patients aged 44 - 89 with inoperable oesophago-gastric carcinomas were intubated with MMS. 18 of these patients had endoscopic laser therapy (ELT) as primary palliation. 25 patients required follow-up endoscopy at variable intervals after stent insertion. 17 patients were found to have significant tumor growth (9), overgrowth (4) and both (4). All these patients were treated with Nd:YAG or diode laser for maintenance of satisfactory swallowing. 4 patients being treated with Nd:YAG laser developed deformity of MMS. This complication was not encountered with diode laser. The reblockage of MMS due to ingrowth or overgrowth of tumor is a not uncommon complication. The timing of the stent insertion should be carefully chosen since the longer the stent is in situ, the greater is the likelihood of tumor ingrowth or overgrowth. ELT can effectively deal with tumor ingrowth and overgrowth. Nd:YAG laser can cause melting of MMS. Overall the combination of ELT and MMS may offer the best palliation, particularly when patient survival of several months is anticipated.

  19. Preoperative biliary drainage using a fully covered self-expandable metallic stent for pancreatic head cancer: A prospective feasibility study.

    Science.gov (United States)

    Togawa, Osamu; Isayama, Hiroyuki; Kawakami, Hiroshi; Nakai, Yousuke; Mohri, Dai; Hamada, Tsuyoshi; Kogure, Hirofumi; Kawakubo, Kazumichi; Sakamoto, Naoya; Koike, Kazuhiko; Kita, Hiroto

    2018-01-01

    The role of endoscopic preoperative biliary drainage (PBD) for pancreatic head cancer is controversial because of the high incidence of stent occlusion before surgery. This study was performed to evaluate the feasibility and safety of PBD using a fully covered self-expandable metallic stent (FCSEMS). This multicenter prospective study involved 26 patients treated for pancreatic head cancer with distal bile duct obstruction from April 2011 to March 2013. An FCSEMS was endoscopically placed in 24 patients. Among these, 7 patients were diagnosed with unresectable cancer, and 17 underwent surgery at a median of 18 days after FCSEMS placement. The main outcome measure was preoperative and postoperative adverse events. Two adverse events (cholecystitis and insufficient resolution of jaundice) occurred between FCSEMS placement and surgery (12%). Postoperative adverse events occurred in eight patients (47%). The cumulative incidence of stent-related adverse events 4 and 8 weeks after FCSEMS placement among the 24 patients who underwent this procedure were 19%. PBD using an FCSEMS is feasible in patients with resectable pancreatic head cancer. Placement of an FCSEMS can be an alternative PBD technique when surgery without delay is impossible. A larger randomized controlled trial is warranted.

  20. Comparison between gastrostomy feeding and self-expandable metal stent insertion for patients with esophageal cancer and dysphagia.

    Science.gov (United States)

    Min, Yang Won; Jang, Eun Young; Jung, Ji Hey; Lee, Hyuk; Min, Byung-Hoon; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J

    2017-01-01

    Self-expandable metal stent (SEMS) insertion and percutaneous gastrostomy (PG) feeding are commonly used for patients with esophageal cancer and dysphagia. This study aimed to compare outcomes between SEMS insertion and PG feeding for them. We retrospectively analyzed 308 patients with esophageal cancer who underwent fully covered SEMS insertion (stent group) or PG (gastrostomy group) for dysphagia due to tumor. Patients with other causes of dysphagia, such as radiation-induced or postoperative stricture, were excluded from the study. Clinical outcomes were compared between the two groups, including overall survival and need for additional intervention and postprocedural nutritional status. At baseline, the stent group (n = 169) had more stage IV patients, less cervical cancers, and received radiotherapy and esophagectomy less often than the gastrostomy group (n = 64). The Kaplan-Meier curves showed higher overall survival in the gastrostomy group than in the stent group. Multivariate analysis revealed that PG was associated with better survival compared with SEMS insertion (hazard ratio 0.541, 95% confidence interval 0.346-0.848, p = 0.007). In addition, the gastrostomy group needed additional intervention less often (3.1% vs. 21.9%, p esophageal cancer and dysphagia. Stabilized nutritional status by PG may play a role in improving patient survival.

  1. Clinical application of self-expanding metallic stent in the management of acute left-sided colorectal malignant obstruction

    Institute of Scientific and Technical Information of China (English)

    You-Ben Fan; Ying-Sheng Cheng; Ni-Wei Chen; Hui-Min Xu; Zhe Yang; Yue Wang; Yu-Yao Huang; Qi Zheng

    2006-01-01

    AIM: To summarize our experience with the application of self-expanding metallic stent (SEMS) in the management of acute left-sided colorectal malignant obstruction.METHODS: A retrospective chart review of all patients undergoing placement of SEMS between April 2000 and January 2004 was performed.RESULTS: Insertion of SEMS was attempted in 26patients under fluoroscopic guidance with occasional endoscopic assistance. The sites of lesions were located in splenic flexure of two patients, left colon of seven patients, sigmoid colon of eight patients and rectum of nine patients. The intended uses of SEMS were for palliation in 7 patients and as a bridge to elective surgery in 19 patients. In the latter group, placement of SEMS allowed for preoperative systemic and bowel preparation and the following one-stage anastomosis. Successful stent placement was achieved in 22 (85%) of the 26patients. The clinical bowel obstruction resolved 24 hours after successful stent placement in 21 (95%) patients.Three SEMS-related minor complications occurred, two stents migrated and one caused anal pain.CONCLUSION: SEMS represents an effective and safe tool in the management of acute malignant colorectal obstruction. As a bridge to surgery, SEMS can provide time for systematic support and bowel preparation and obviate the need for fecal diversion or on-table lavage.As a palliative measure, SEMS can eliminate the need for emergent colostomy.

  2. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    International Nuclear Information System (INIS)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho; Ko, Ji Ho; Jeong, Kyung Soon

    2007-01-01

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

  3. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    Science.gov (United States)

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  4. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    Science.gov (United States)

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  5. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of University, Masan (Korea, Republic of); Jeong, Kyung Soon [University of Ulsan Colleg of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer.

  6. Insertion of a self-expandable metallic stent in canine lacrimal Sac : a long-term evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Sung, Kyu Bo; Yoon, Hyun Ki [Univ. of Ulsan, Ulsan (Korea, Republic of). College of Medicine; Kwon, Soon Tae [Chungnam National Univ., Taejon (Korea, Republic of). Medical School; Lee, Ho Jung; Lee, In Chul; Kim, Tae Hyung; Park, Sang Soo; Huh, Soo Jin [Univ. of Ulsan, Ulsan (Korea, Republic of). College of Medicine

    1998-01-01

    To evaluate the feasibility and long-term outcome of the use of self-expandable metallic Z-stents in the canine lacrimal sac. Stent placement was technically successful and well tolerated in all but one lacrimal sac, in which the stent was misplaced. At three and six months after stent placement, stent wires were not encased by epithelium, but at nine months, and one, two and three years after placement, six of the 12 stents had become encased in a proliferation of this where the stent wires contacted the lacrimal sac wall. In no lacrimal system in which stent placement had been successful was migration, stenosis or obstruction of the lacrimal system observed. One misplaced stent caused obstruction of the lacrimal sac, however . In 11 of 12 case (92%), fluoroscopic placement of an expandable metallic stent in the canine lacrimal sac was successful: in 6 of 8 cases (75%), the stent wires became encased by a proliferation of mucosa, but during long-term follow-up of 9 months to 3 years, no obstruction was observed. (author). 20 refs., 1 tab., 5 figs.

  7. Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases.

    Science.gov (United States)

    Tanisaka, Yuki; Ryozawa, Shomei; Kobayashi, Masanori; Harada, Maiko; Kobatake, Tsutomu; Omiya, Kumiko; Iwano, Hirotoshi; Arai, Shin; Nonaka, Kouichi; Mashimo, Yumi

    2018-02-01

    Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117-205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5-24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed.

  8. Self-expandable Metallic Stents Contribute to Reducing Perioperative Complications in Colorectal Cancer Patients with Acute Obstruction.

    Science.gov (United States)

    Furuke, Hirotaka; Komatsu, Shuhei; Ikeda, Jun; Tanaka, Sachie; Kumano, Tatsuya; Imura, Ken-Ichiro; Shimomura, Katsumi; Taniguchi, Fumihiro; Ueshima, Yasuo; Takashina, Ken-Ichiro; Lee, Chol Joo; Deguchi, Eiichi; Ikeda, Eito; Otsuji, Eigo; Shioaki, Yasuhiro

    2018-03-01

    The self-expandable metallic stent (SEMS) is an excellent non-invasive tool for emergent bowel obstruction. This study was designed to evaluate the clinical usefulness of the SEMS for avoiding perioperative complications. We analyzed a total of 47 consecutive patients who had a bowel obstruction due to colorectal cancer at initial diagnosis between 2012 and 2017 from hospital records. Perioperative complications occurred in 30% (14/47) of patients. Univariate and multivariate logistic regression analyses identified an age of more than 75 years [p=0.037, OR=6.84 (95% CI=1.11-41.6)] and the absence of an SEMS treatment [p=0.028, OR=18.5 (95% CI=1.36-250.0)] as independent risk factors for perioperative complications. Pneumonia (12.7% (6/47)) was the most common complication. There were no pneumonia patients (0% (0/15)) who were treated with the SEMS. In contrast to patients with the non-SEMS treatment, 18.7% (6/32) of all patients and 35.7% (5/14) of elderly patients had pneumonia. The SEMS is a safe and effective treatment for avoiding perioperative complications, particularly pneumonia, and may be a crucial strategy in elderly patients with acute obstruction due to colorectal cancer. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  9. Palliative self-expandable metal stents for acute malignant colorectal obstruction: clinical outcomes and risk factors for complications.

    Science.gov (United States)

    Han, Jae Pil; Hong, Su Jin; Kim, Shin Hee; Choi, Jong Hyo; Jung, Hee Jae; Cho, Youn Hee; Ko, Bong Min; Lee, Moon Sung

    2014-08-01

    Self-expandable metal stents (SEMSs) have been used as palliative treatment or bridge to surgery for obstructions caused by colorectal cancer (CRC). We assessed the long-term outcomes of palliative SEMSs and evaluated the risk factors influencing complications. One hundred and seventy-five patients underwent SEMS placement for acute malignant colorectal obstruction. Of the 72 patients who underwent palliative treatment for primary CRC, 30 patients received chemotherapy (CT) for primary cancer (CT group) and 42 underwent best supportive treatment (BST) without CT (BST group). There was a significant difference in late migration between the CT group and the BST group (20.0% in CT group, 2.4% in BST group, p = 0.018). Response to CT influenced the rate of late obstruction (0% in disease control, 35.7% in disease progression, p = 0.014). However, late obstruction was not associated with stent properties, such as diameter or type (≤22 mm vs. >22 mm, 13.5% vs. 14.3%, p = 1.00; uncovered stent vs. covered stent, 15.5% vs. 7.1%, p = 0.675) and migration (≤22 mm vs. >22 mm, 16.2% vs. 2.9%, p = 0.108; uncovered stent vs. covered stent, 8.6% vs. 14.3%, p = 0.615) in palliative SEMS. The administration of CT increases the rate of stent migration, and disease control by CT can reduce the risk of obstruction by maintaining the luminal patency of palliative SEMSs.

  10. A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.

    Science.gov (United States)

    Takahara, Naminatsu; Isayama, Hiroyuki; Nakai, Yousuke; Yoshida, Shuntaro; Saito, Tomotaka; Mizuno, Suguru; Yagioka, Hiroshi; Kogure, Hirofumi; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Tada, Minoru; Koike, Kazuhiko

    2017-07-15

    Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.

  11. Reocclusion after Self-Expandable Metallic Stent Placement for Relieving Malignant Colorectal Obstruction as a Palliative Treatment

    Directory of Open Access Journals (Sweden)

    Toshikatsu Nitta

    2016-12-01

    Full Text Available Self-expandable metallic stent (SEMS placement has been practiced in several hospitals in Japan, including ours, since January 2012. Here, we report the case of an 82-year-old Japanese man who presented to the hospital with a 1-week history of right hypochondrial pain. Computed tomography (CT findings indicated colorectal cancer. The laboratory findings on admission indicated severe anemia (red blood cell count, 426 × 104/μL; hemoglobin, 7.9 g/dL. We performed SEMS placement because the patient refused to undergo surgery. He did not attend any of the scheduled follow-up visits after SEMS placement. However, a year and a half after the SEMS placement, the patient attended the hospital because of difficulty in passing stool. A plain abdominal CT scan showed bowel reobstruction due to the ascending colon cancer after SEMS placement. We performed an emergency operation, ascending colostomy, on the same day. Colorectal stent placement may be a good treatment option for patients who refuse to undergo conventional therapeutic treatments or in those with unresectable colorectal cancer. Patients should be carefully followed up every few months after SEMS placement because of the risk of reocclusion.

  12. Tracheal Self-Expandable Metallic Stents: A Comparative Study of Three Different Stents in a Rabbit Model.

    Science.gov (United States)

    Serrano, Carolina; Lostalé, Fernando; Rodríguez-Panadero, Francisco; Blas, Ignacio de; Laborda, Alicia; de Gregorio, Miguel Angel

    2016-03-01

    The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; Pstent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; Pstent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  13. Clinical Impact of Prophylactic Antibiotic Treatment for Self-Expandable Metallic Stent Insertion in Patients with Malignant Colorectal Obstruction

    Directory of Open Access Journals (Sweden)

    Jong-Sun Kim

    2015-01-01

    Full Text Available Purpose. The aim of this study was to determine the efficacy of prophylactic antibiotics (PA for reducing the infectious complications and the potential risk factors responsible for the infectious complications after stent insertion for malignant colorectal obstruction. Methods. We performed a retrospective review of 224 patients who underwent self-expandable metallic stent (SEMS insertion for malignant colorectal obstruction from May 2004 to December 2012. Results. There were 145 patients in the PA group and 79 in non-PA group. The CRP level in PA group was significantly higher than that in non-PA. Abdominal tenderness and mechanical ileus were significantly more frequent in PA group than those in non-PA. The frequency of post-SEMS insertion fever, systemic inflammatory response syndrome (SIRS, and bacteremia was not significantly different between PA and non-PA groups. In multivariate analysis, the CRP level was risk factor related to post-SEMS insertion SIRS. However, in propensity score matching analysis, there was no independent risk factor related to post-SEMS insertion fever, SIRS, and bacteremia. Conclusion. The use of PA in patients with malignant colorectal obstruction may be not effective to prevent the development of infectious complications after SEMS insertion.

  14. Effectiveness and Safety of Endoscopic Treatment of Benign Biliary Strictures Using a New Fully Covered Self Expandable Metal Stent

    Directory of Open Access Journals (Sweden)

    Mihir S. Wagh

    2013-01-01

    Full Text Available Background. In patients with benign biliary strictures, the use of fully covered self-expandable metal stents (SEMS has been proposed as an alternative to plastic stenting, but high quality prospective data are sparse. This study was performed to evaluate the long-term effectiveness and safety of a new fully covered SEMS for benign biliary strictures. Methods. All consecutive patients with benign biliary strictures were treated with placement of a fully covered SEMS (WallFlex for 6 months. Short- and long-term stricture resolution, adverse events, and ease of stent removal were recorded. Results. 23 patients were enrolled. Stricture etiology was chronic pancreatitis (14, postorthotopic liver transplant (4, idiopathic (4, and biliary stones (1. All ERCPs were technically successful. All stents were successfully removed. Short-term stricture resolution was seen in 22/23 (96% patients. Long-term success was 15/18 (83.3%. All 3 failures were patients with biliary strictures in the setting of chronic calcific pancreatitis. Conclusions. The use of the new SEMS for the treatment of benign biliary strictures led to short-term stricture resolution in the vast majority of patients. Over a long-term followup the success rate appears favorable compared to historical results achieved with multiple plastic stenting, particularly in patients with chronic pancreatitis. The study was registered with ClinicalTrials.gov (NCT01238900.

  15. Insertion of a self-expandable metallic stent in canine lacrimal Sac : a long-term evaluation

    International Nuclear Information System (INIS)

    Song, Ho Young; Sung, Kyu Bo; Yoon, Hyun Ki; Kwon, Soon Tae; Lee, Ho Jung; Lee, In Chul; Kim, Tae Hyung; Park, Sang Soo; Huh, Soo Jin

    1998-01-01

    To evaluate the feasibility and long-term outcome of the use of self-expandable metallic Z-stents in the canine lacrimal sac. Stent placement was technically successful and well tolerated in all but one lacrimal sac, in which the stent was misplaced. At three and six months after stent placement, stent wires were not encased by epithelium, but at nine months, and one, two and three years after placement, six of the 12 stents had become encased in a proliferation of this where the stent wires contacted the lacrimal sac wall. In no lacrimal system in which stent placement had been successful was migration, stenosis or obstruction of the lacrimal system observed. One misplaced stent caused obstruction of the lacrimal sac, however . In 11 of 12 case (92%), fluoroscopic placement of an expandable metallic stent in the canine lacrimal sac was successful: in 6 of 8 cases (75%), the stent wires became encased by a proliferation of mucosa, but during long-term follow-up of 9 months to 3 years, no obstruction was observed. (author). 20 refs., 1 tab., 5 figs

  16. Outcomes and complications of self-expanding metal stent placement for malignant colonic obstruction in a single-center study.

    Science.gov (United States)

    Stankiewicz, Rafał; Kozieł, Sławomir; Pertkiewicz, Jan; Zieniewicz, Krzysztof

    2018-03-01

    Approximately 20% of cases of colorectal cancer are accompanied by acute colonic obstruction. While emergency colonic surgery is associated with high mortality and morbidity rates, placement of a self-expanding metal stent (SEMS) has been suggested as an alternative method. The SEMS placement can serve as either a definitive treatment in palliative cases or a bridge to surgery. To summarize the experience of our center in the treatment of malignant colonic obstruction using SEMS placement. A retrospective review was conducted of all patients who underwent a SEMS placement for colorectal stricture in the study period. The procedures were performed under fluoroscopic guidance with colonoscopic assistance, and uncovered stents were used in all patients. The study population consisted of 28 patients treated with SEMS placement due to malignant colonic obstruction. The majority of procedures were performed with palliative intent. The overall technical success rate was 96.5%, and clinical success was achieved in all of the successfully placed SEMSs. One fatal complication due to colonic perforation occurred. In the bridge-to-surgery group, all patients experienced tumor resection with no stoma creation. The SEMS placement is an optimal treatment in the vast majority of acute colonic obstruction cases. Due to the possibility of potentially fatal complications, SEMS procedures should be performed by proficient endoscopists.

  17. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Leto, John; George, Christopher; Van Epps, Kelly; Woeste, Troy; Berlet, Mathew

    2008-01-01

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus

  18. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  19. Bifurcations of optimal vector fields: an overview

    NARCIS (Netherlands)

    Kiseleva, T.; Wagener, F.; Rodellar, J.; Reithmeier, E.

    2009-01-01

    We develop a bifurcation theory for the solution structure of infinite horizon optimal control problems with one state variable. It turns out that qualitative changes of this structure are connected to local and global bifurcations in the state-costate system. We apply the theory to investigate an

  20. Bifurcation of the spin-wave equations

    International Nuclear Information System (INIS)

    Cascon, A.; Koiller, J.; Rezende, S.M.

    1990-01-01

    We study the bifurcations of the spin-wave equations that describe the parametric pumping of collective modes in magnetic media. Mechanisms describing the following dynamical phenomena are proposed: (i) sequential excitation of modes via zero eigenvalue bifurcations; (ii) Hopf bifurcations followed (or not) by Feingenbaum cascades of period doubling; (iii) local and global homoclinic phenomena. Two new organizing center for routes to chaos are identified; in the classification given by Guckenheimer and Holmes [GH], one is a codimension-two local bifurcation, with one pair of imaginary eigenvalues and a zero eigenvalue, to which many dynamical consequences are known; secondly, global homoclinic bifurcations associated to splitting of separatrices, in the limit where the system can be considered a Hamiltonian subjected to weak dissipation and forcing. We outline what further numerical and algebraic work is necessary for the detailed study following this program. (author)

  1. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F L [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  2. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  3. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  4. Bifurcation and chaos in neural excitable system

    International Nuclear Information System (INIS)

    Jing Zhujun; Yang Jianping; Feng Wei

    2006-01-01

    In this paper, we investigate the dynamical behaviors of neural excitable system without periodic external current (proposed by Chialvo [Generic excitable dynamics on a two-dimensional map. Chaos, Solitons and Fractals 1995;5(3-4):461-79] and with periodic external current as system's parameters vary. The existence and stability of three fixed points, bifurcation of fixed points, the conditions of existences of fold bifurcation, flip bifurcation and Hopf bifurcation are derived by using bifurcation theory and center manifold theorem. The chaotic existence in the sense of Marotto's definition of chaos is proved. We then give the numerical simulated results (using bifurcation diagrams, computations of Maximum Lyapunov exponent and phase portraits), which not only show the consistence with the analytic results but also display new and interesting dynamical behaviors, including the complete period-doubling and inverse period-doubling bifurcation, symmetry period-doubling bifurcations of period-3 orbit, simultaneous occurrence of two different routes (invariant cycle and period-doubling bifurcations) to chaos for a given bifurcation parameter, sudden disappearance of chaos at one critical point, a great abundance of period windows (period 2 to 10, 12, 19, 20 orbits, and so on) in transient chaotic regions with interior crises, strange chaotic attractors and strange non-chaotic attractor. In particular, the parameter k plays a important role in the system, which can leave the chaotic behavior or the quasi-periodic behavior to period-1 orbit as k varies, and it can be considered as an control strategy of chaos by adjusting the parameter k. Combining the existing results in [Generic excitable dynamics on a two-dimensional map. Chaos, Solitons and Fractals 1995;5(3-4):461-79] with the new results reported in this paper, a more complete description of the system is now obtained

  5. Comparison on the Efficacy between Partially Covered Self-Expandable Metal Stent with Funnel-Shaped Enlarged Head versus Uncovered Self-Expandable Metal Stent for Palliation of Gastric Outlet Obstruction

    Directory of Open Access Journals (Sweden)

    Jung Wan Choe

    2018-01-01

    Full Text Available Background. Shape modification has been one of the methods adopted to improve stent patency but has not always translated into positive outcome. The aim of this study was to compare the efficacy of shape-modified partially covered self-expandable metal stent (SEMS that has enlarged head versus uncovered SEMS for palliation of gastric outlet obstruction (GOO. Methods. A total of 48 patients underwent insertion of either enlarged-head SEMS (n=24 or uncovered SEMS (uSEMS (n=24 for palliation of GOO from July 2009 to July 2016. Patients with inoperable or advanced malignancy were included. Technical feasibility and clinical outcomes were compared. Results. Technical success rate was 100% (24/24 and 95.8% (23/24 for enlarged-head SEMS group and uSEMS group, respectively. Clinical success rate was 87.5% (21/24 and 87.0% (20/23 for enlarged-head SEMS group and uSEMS group, respectively. The gastric outlet obstruction scoring system score significantly improved in both groups (p<0.001 for both. Mean survival was similar between the groups: enlarged-head SEMS group, 99.3 days (range, 19–358 days versus uSEMS group, 82.1 days (range, 11–231 days (p=0.418. The mean stent patency also showed no difference between the groups: enlarged-head SEMS group, 87.1 days (range, 8–358 days versus uSEMS group, 60.4 days (range, 2–231 days (p=0.204. With enlarged-head SEMS, distal migration did not occur, but proximal migration was observed in four cases. Conclusions. Distal migration was prevented by shaping the SEMS to have an enlarged head, but improvement in stent patency could not be observed.

  6. Predictors of Complications and Mortality in Patients with Self-Expanding Metallic Stents for the Palliation of Malignant Colonic Obstruction

    Science.gov (United States)

    Sousa, Mafalda; Pinho, Rolando; Proença, Luísa; Silva, Joana; Ponte, Ana; Rodrigues, Jaime; Carvalho, João

    2017-01-01

    Introduction Self-expanding metallic stents (SEMS) for palliative purposes in malignant colonic obstruction are an alternative to surgery that has gained popularity over time. Methods We performed a retrospective study of patients submitted to SEMS for palliation of obstructing malignant colorectal cancer from 2005 to 2015 to evaluate predictive clinical factors for complications and mortality. Results Forty-five patients with high rates of technical and clinical success were included (97.8 and 95.6%, respectively), with complications occurring in 17.8% (8.9% perforations, 4.4% obstructions, and 4.4% migrations). The length of the stenosis was superior in patients with complications (p = 0.01); 11.1% of patients had a re-intervention (2.2% surgery and 8.9% placement of another SEMS). Relief of obstruction without intervention was maintained until death in 77.8% of patients and in 81.4% of patients who had immediate clinical success. The mortality rate was 37.2% at 30 days, 56.5% at 60 days, and 87.5% at 1 year. There were no predictors of survival identified, including age, sex, tumor stage, metastasis, or complications of the procedure. Discussion and Conclusions In this study, SEMS placement was associated with a high rate of technical and clinical success and a low rate of complications, being an option to palliate patients with obstructive neoplasia. The length of the stenosis was associated with a greater risk of complications. The majority of stent-related complications can be managed successfully without surgery. PMID:28848796

  7. Covered self-expandable metal stents in pancreatic malignancy regardless of resectability: a new concept validated by a decision analysis.

    Science.gov (United States)

    Kahaleh, M; Brock, A; Conaway, M R; Shami, V M; Dumonceau, J M; Northup, P G; Tokar, J; Rich, T A; Adams, R B; Yeaton, P

    2007-04-01

    The current treatment model for the management of malignant biliary obstruction is to place a plastic stent for unstaged pancreatic cancer. In patients with unresectable disease but a life expectancy of more than 6 months, self-expandable metal stents (SEMS) are favored because of their more prolonged patency. We analyzed the efficacy and cost-effectiveness of covered SEMS (CSEMS) in patients with pancreatic cancer and distal biliary obstruction without regard to surgical resectability. Between March 2001 and March 2005, 101 consecutive patients with obstructive jaundice secondary to pancreatic cancer underwent placement of a CSEMS. Patients with resectable tumor were offered pancreaticoduodenectomy. A model was developed to compare the costs of CSEMS and polyethylene and DoubleLayer stents. A total of 21 patients underwent staging laparoscopy, of whom 16 had a resection (76%). The 85 patients who did not have a resection had a mean survival of 5.9 months (range 1-25 months) and a mean CSEMS patency duration of 5.5 months (range 1-16 months). Life-table analysis demonstrated CSEMS patency rates of 97% at 3 months, 85% at 6 months, and 68% at 12 months. In a cost model that accounted for polyethylene and DoubleLayer stent malfunction and surgical resections, initial CSEMS placement (3177 euros per patient) was a less costly intervention than either DoubleLayer stent placement (3224 euros per patient) or polyethylene stent placement with revision (3570 euros per patient). Covered SEMS are an effective treatment for distal biliary obstructions caused by pancreatic carcinoma. Their prolonged patency and removability makes them an attractive option for biliary decompression, regardless of resectability. The strategy of initial covered SEMS placement might be the most cost-effective strategy in these patients.

  8. Application of Y-shaped, coated self-expandable metallic stents for anastomotic stenosis after gastrojejunostomy (Billroth II).

    Science.gov (United States)

    Li, Teng-Fei; Wu, Gang; Han, Xin-Wei; Shui, Shao-Feng; Ren, Jian-Zhuang; Li, Zhen; Ren, Ke-Wei

    2017-01-01

    Anastomotic stenosis is an infrequent but life-threatening complication after gastrojejunostomy (Billroth II). Tubular or single tubular stents have limited efficacy due to the particular anatomy. To assess the feasibility of a Y-shaped, fully-coated, self-expandable, metallic stent (SEMS) for anastomotic stenosis after gastrojejunostomy (Billroth II). Between January 2008 and August 2014, 14 patients (10 with gastric carcinoma and four with duodenal ulcers) had anastomotic stenoses following Billroth II reconstructions. Eight patients with gastric cancer had tumor recurrence near the anastomosis; two had benign strictures. The four duodenal ulcer patients had benign stenoses. An integrated Y-shaped, fully coated SEMS was designed to accord with the anatomy of residual gastrojejunal anastomotic strictures. Fourteen stents were inserted under fluoroscopic control. Follow-up was at 1, 3, 9, and 12 months, and then annually. All 14 stents were inserted successfully at the first attempt with a technical success rate of 100%. After stenting, abdominal symptoms resolved in all patients. All patients were followed up for 4-27 months (mean, 13.9 months). One of the eight recurrent cases died of multiple tumor metastases and liver failure after 7 months, without obstruction symptoms. In all six patients with benign anastomotic stenosis, the stents were removed successfully without complication and with no evidence of restenosis based on clinical evaluation and imaging. A Y-shaped, fully-coated SEMS proved to be a feasible and minimally invasive procedure for treating anastomotic stenosis after gastrojejunostomy (Billroth II). © The Foundation Acta Radiologica 2016.

  9. Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center

    International Nuclear Information System (INIS)

    Park, Jung-Hoon; Kim, Pyeong Hwa; Shin, Ji Hoon; Tsauo, Jiaywei; Kim, Min Tae; Cho, Young Chul; Kim, Jin Hyoung; Song, Ho-Young

    2016-01-01

    PurposeThe purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures.Materials and MethodsA total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success.ResultsPrimary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071–0.874, P = 0.030).ConclusionRemoval of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

  10. Comparative Study of Esophageal Self-expandable Metallic Stent Insertion and Gastrostomy Feeding for Dysphagia Caused by Lung Cancer.

    Science.gov (United States)

    Kim, Jihye; Min, Yang Won; Lee, Hyuk; Min, Byung Hoon; Lee, Joon Haeng; Rhee, Poong Lyul; Kim, Jae J

    2018-03-25

    Dysphagia is encountered in a large proportion of patients with lung cancer and is associated with malnutrition and a poor quality of life. This study compared the clinical outcomes of self-expandable metallic stent (SEMS) insertion and percutaneous gastrostomy (PG) feeding for patients with lung cancer and dysphagia. A total of 261 patients with lung cancer, who underwent either SEMS insertion (stent group) or PG (gastrostomy group) as an initial treatment procedure for dysphagia between July 1997 and July 2015 at the Samsung Medical Center, were reviewed retrospectively, and 84 patients with esophageal obstruction were identified. The clinical outcomes, including the overall survival, additional intervention, complications, and post-procedural nutritional status in the two groups, were compared. Among the 84 patients finally analyzed, 68 patients received SEMS insertion and 16 had PG. The stent group had less cervical obstruction and more mid-esophageal obstruction than the gastrostomy group. The Kaplan-Meier curves revealed similar overall survival in the two groups. Multivariate analysis showed that the two modalities had similar survival rates (PG compared with SEMS insertion, hazard ratio 0.682, p=0.219). Fifteen patients (22.1%) in the stent group received additional intervention, whereas there was no case in the gastrostomy group (p=0.063). The decrease in the serum albumin level after the procedure was lower in the gastrostomy group than in the stent group (-0.20±0.54 g/dL vs. -0.65±0.57 g/dL, p=0.013). SEMS insertion and PG feeding for relieving dysphagia by lung cancer had a comparable survival outcome. On the other hand, PG was associated with a better nutritional status.

  11. Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung-Hoon; Kim, Pyeong Hwa; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr; Tsauo, Jiaywei; Kim, Min Tae; Cho, Young Chul; Kim, Jin Hyoung; Song, Ho-Young [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2016-11-15

    PurposeThe purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures.Materials and MethodsA total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success.ResultsPrimary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071–0.874, P = 0.030).ConclusionRemoval of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

  12. Outcome and risk factors assessment for adverse events in advanced esophageal cancer patients after self-expanding metal stents placement.

    Science.gov (United States)

    Rodrigues-Pinto, E; Pereira, P; Coelho, R; Andrade, P; Ribeiro, A; Lopes, S; Moutinho-Ribeiro, P; Macedo, G

    2017-02-01

    Self-expanding metal stents (SEMS) are the treatment of choice for advanced esophageal cancers. Literature is scarce on risk factors predictors for adverse events after SEMS placement. Assess risk factors for adverse events after SEMS placement in advanced esophageal cancer and evaluate survival after SEMS placement. Cross-sectional study of patients with advanced esophageal cancer referred for SEMS placement, during a period of 3 years. Ninety-seven patients with advanced esophageal cancer placed SEMS. Adverse events were more common when tumors were located at the level of the distal esophagus/cardia (47% vs 23%, P = 0.011, OR 3.1), with statistical significance being kept in the multivariate analysis (OR 3.1, P = 0.018). Time until adverse events was lower in the tumors located at the level of the distal esophagus/cardia (P = 0.036). Survival was higher in patients who placed SEMS with curative intent (327 days [126-528] vs. 119 days [91-147], P = 0.002) and in patients submitted subsequently to surgery compared with those who did just chemo/radiotherapy or who did not do further treatment (563 days [378-748] vs. 154 days [133-175] vs. 46 days [20-72], P dysphagia in advanced esophageal cancer and are associated with an increased out-of-hospital survival, as long as there are conditions for further treatments. Tumors located at the level of the distal esophagus/cardia are associated with a greater number of adverse events, which also occur earlier. © 2016 International Society for Diseases of the Esophagus.

  13. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    Science.gov (United States)

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2017-09-01

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  14. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  15. Management of acute malignant colorectal obstruction with a novel self-expanding metallic stent as a bridge to surgery

    International Nuclear Information System (INIS)

    Li Yongdong; Cheng Yingsheng; Li Minghua; Fan Youben; Chen Niwei; Wang Yu; Zhao Jungong

    2010-01-01

    Purpose: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) in the treatment of patients with acute malignant colorectal obstruction. Methods: Between April 2001 and October 2007, 52 patients with acute malignant colorectal obstruction were treated with a new designed SEMS as an investigational bridge to surgery. Patients were prospectively followed and relevant data collection was collected, including details regarding technique, clinical symptoms, complications, need for elective surgery, and overall survival. Results: Stent placement was technically successful in all but two patients (due to complete obstruction) with no procedure-related complications. Complications included stent migration (n = 4), anal pain (n = 2) and stool impaction (n = 1). Clinical success was achieved in 49 (98%) of 50 patients with resolution of bowel obstruction within 2 days of stent placement. In one patient with stool impaction 2 days after stent placement, endoscopic disimpaction was successfully performed. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS as a bridge to surgery within a mean of 8 ± 2 days (range: 4-11 days) after stent placement. Mean follow-up time was 36 ± 12 months (range 3-70 months), and all patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement as a bridge to surgery was a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction and allowed a high proportion of patients to be successfully proceeded to elective surgery.

  16. Impact of Carcinomatosis on Clinical Outcomes after Self-Expandable Metallic Stent Placement for Malignant Gastric Outlet Obstruction.

    Directory of Open Access Journals (Sweden)

    Ji Eun Lee

    Full Text Available It is still unclear whether the peritoneal carcinomatosis had a negative effect on the clinical outcomes of patients who underwent self-expandable metallic stent (SEMS placement for malignant gastric outlet obstruction (GOO. Although carcinomatosis may be associated with the development of multifocal gastrointestinal (GI tract obstruction or decreased bowel movement, previous studies investigated the occurrence of stent failure only and thus had limitation in evaluating clinical outcomes of patients with carcinomatosis.Between 2009 and 2013, 155 patients (88 patients without carcinomatosis and 67 patients with carcinomatosis underwent endoscopic SEMS placement for malignant GOO. Factors affecting clinical success and obstructive symptom-free survival (time period between SEMS placement and the recurrence of obstructive symptoms due to multifocal GI tract obstruction or decreased bowel movement as well as stent failure were assessed.Patients with carcinomatosis showed higher Eastern Cooperative Oncology Group (ECOG scale than those without carcinomatosis. Clinical success rates were 88.1% in patients with carcinomatosis and 97.7% in patients without carcinomatosis. In multivariate analysis, only ECOG scale was identified as an independent predictor of clinical success. During follow-up period, patients with carcinomatosis showed significantly shorter obstructive symptom-free survival than those without carcinomatosis. In multivariate analysis, the presence of carcinomatosis, chemotherapy or radiation therapy after SEMS placement, and obstruction site were identified as independent predictors of obstructive symptom-free survival. For patient without carcinomatosis, stent failure accounted for the recurrence of obstructive symptoms in 84.6% of cases. For patients with carcinomatosis, multifocal GI tract obstruction or decreased bowel movement accounted for 37.9% of cases with obstructive symptom recurrence and stent failure accounted for 44.8% of

  17. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  18. Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas.

    Science.gov (United States)

    Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán

    2017-08-01

    Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.

  19. Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center.

    Science.gov (United States)

    Park, Jung-Hoon; Kim, Pyeong Hwa; Shin, Ji Hoon; Tsauo, Jiaywei; Kim, Min Tae; Cho, Young Chul; Kim, Jin Hyoung; Song, Ho-Young

    2016-11-01

    The purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures. A total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success. Primary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071-0.874, P = 0.030). Removal of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

  20. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.

    Science.gov (United States)

    Inoue, Tadahisa; Naitoh, Itaru; Okumura, Fumihiro; Ozeki, Takanori; Anbe, Kaiki; Iwasaki, Hiroyasu; Nishie, Hirotada; Mizushima, Takashi; Sano, Hitoshi; Nakazawa, Takahiro; Yoneda, Masashi; Joh, Takashi

    2016-11-01

    Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent. © 2016 Japan Gastroenterological Endoscopy Society.

  1. Efficacy and safety of a new fully covered self-expandable non-foreshortening metal esophageal stent.

    Science.gov (United States)

    Dua, Kulwinder S; Latif, Sahibzada U; Yang, Juliana F; Fang, Tom C; Khan, Abdul; Oh, Young

    2014-10-01

    Fully covered esophageal self-expandable metal stents (SEMSs) are potentially removable but can be associated with high migration rates. For precise positioning, non-foreshortening SEMSs are preferred. Recently, a new fully covered non-foreshortening SEMS with anti-migration features was introduced. To evaluate the efficacy and safety of this new esophageal SEMS. Retrospective study. Single, tertiary-care center. Consecutive patients with malignant and benign strictures with dysphagia grade of ≥3 and patients with fistulas/leaks were studied. Stent placement and removal. Technical success in stent deployment/removal, efficacy in relieving dysphagia and sealing fistulas/leaks, and adverse events. Forty-three stents were placed in 35 patients (mean [± standard deviation] age 65 ± 11 years; 31 male), 24 for malignant and 11 for benign (5 strictures, 6 leaks) indications. Technical success in precise SEMS placement was 100%. The after-stent dysphagia grade improved significantly (at 1 week: 1.5 ± 0.7; at 4 weeks: 1.2 ± 0.4; baseline: 3.8 ± 0.4; P stents were removed for clinical indications, with technical success of 100%. All leaks sealed after SEMS placement and did not recur after stent removal. All benign strictures recurred after stent removal. Adverse events included migration (14%), chest pain (11%), and dysphagia from tissue hyperplasia (6%). There was no stent-related mortality. Nonrandomized, single-center study. The new esophageal SEMS was effective in relieving malignant dysphagia, allowed for precise placement, and was easily removable. It was effective in treating benign esophageal fistulas and leaks. Stent-related adverse events were acceptable. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Full covered self-expandable metal stents for the treatment of anastomotic leak using a silk thread.

    Science.gov (United States)

    Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Park, Su Bum; Kim, Su Jin; Hwang, Sun Hwi; Lee, Si Hak

    2017-07-01

    To evaluate the safety and effectiveness of fixation of the fully covered self-expandable metal stent (SEMS) placement using a silk thread for complete closure of an anastomotic leak. An anastomotic leak is a life-threatening complication after gastrectomy. Although the traditional treatment of choice was surgical re-intervention, an endoscopic SEMS can be used alternatively.During the study period, we retrospectively reviewed consecutive patients who received a modified covered SEMS capable of being fixed using a silk thread (Shim technique) due to an anastomotic leak after gastrectomy to prevent stent migration. Demographic data, stent placement and removal, clinical success, time to resolution, and complications were evaluated.A total of 7 patients underwent fully covered SEMS with a silk thread placement for an anastomotic leak after gastrectomy to treat gastric cancer. The patients' mean age was 71.3 ± 8.0 years. Man sex was predominant (85.7%). All patients' American Society of Anesthesiologists (ASA) scores were between I and III. Total gastrectomy was performed in 5 patients (71.4%) and proximal gastrectomy was performed in 2 patients (28.6%). The time between gastrectomy and stent insertion was 22.3 ± 11.1 days. The size of the leaks was 27.1 ± 11.1 mm. Technical success and complete leak closure were achieved in all patients. Stent migration was absent. All stents were removed between 4 and 6 weeks. Delayed esophageal stricture was found in 1 patient (14.2) and successfully resolved after endoscopic balloon dilation.For an anastomotic leak after gastrectomy, fully covered SEMS placement with a silk thread is an effective and safe treatment option without stent migration. The stent extraction time between 4 and 6 weeks was optimal without severe complications.

  3. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.

    Science.gov (United States)

    Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2014-03-01

    Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  4. Efficacy and safety of limited endoscopic sphincterotomy before self-expandable metal stent insertion for malignant biliary obstruction.

    Science.gov (United States)

    Nam, Hyeong Seok; Kang, Dae Hwan; Kim, Hyung Wook; Choi, Cheol Woong; Park, Su Bum; Kim, Su Jin; Ryu, Dae Gon

    2017-03-07

    To evaluate the safety and efficacy of limited endoscopic sphincterotomy (ES) before placement of self-expandable metal stent (SEMS). This was a retrospective analysis of 244 consecutive patients with unresectable malignant biliary obstruction, who underwent placement of SEMSs following limited ES from December 2008 to February 2015. The diagnosis of malignant biliary obstruction and assessment of patient eligibility for the study was established by a combination of clinical findings, laboratory investigations, imaging and pathological results. All patients were monitored in the hospital for at least 24 h following endoscopic retrograde cholangio pancreatography (ERCP). The incidence of immediate or early post-ERCP complications such as post-ERCP pancreatitis (PEP) and bleeding related to limited ES were considered as primary outcomes. Also, characteristics and complications according to the cancer type were classified. Among the 244 patients included, the underlying diagnosis was cholangiocarcinoma in 118 patients, pancreatic cancer in 79, and non-pancreatic or non-biliary malignancies in the remaining 47 patients. Early post-ERCP complications occurred in 9 patients (3.7%), with PEP in 7 patients (2.9%; mild, 6; moderate, 1) and mild bleeding in 2 patients (0.8%). There was no significant association between the incidence of post-ERCP complications and the type of malignancy (cholangiocarcinoma vs pancreatic cancer vs others, P = 0.696) or the type of SEMS used (uncovered vs covered, P = 1.000). Patients who had more than one SEMS placed at the first instance were at a significantly higher risk of post-ERCP complications (one SEMS vs two SEMS, P = 0.031). No other factors were predictive of post-ERCP complications. Limited ES is feasible and safe, and effectively facilitates the placement of SEMS, without any significant risk of PEP or severe bleeding.

  5. Self-expandable metallic stent as a bridge to elective surgery versus emergency surgery for acute malignant colorectal obstruction.

    Science.gov (United States)

    Li, Zhi-Xiong; Wu, Xiao-Hua; Wu, Hai-yan; Chang, Wen-Ju; Chang, Xiu-juan; Yi, Tuo; Shi, Qiang; Chen, Jing-Wen; Feng, Qing-Yang; Zhu, De-Xiang; Wei, Ye; Zhong, Yun-Shi; Xu, Jian-Min

    2016-03-01

    The efficacy and safety of self-expandable metallic stents (SEMSs) as a bridge for patients with acute malignant colorectal obstructions (AMCOs) are still controversial. We conducted this study to evaluate the outcomes of patients with AMCOs treated by different strategies. From January 2010 to March 2014, a total of 171 patients with AMCOs from Zhongshan Hospital were retrospectively enrolled in this study. One hundred twenty patients successfully received stent placement followed by one-stage laparoscopic or open resection in the stent group, and 51 patients received emergency operations in the emergency group. The operation duration and postoperative hospital stay were significantly shorter in the stent group (114.51 ± 28.65 vs. 160.39 ± 58.94 min, P stent group also had significantly reduced intraoperative blood loss and the incidence of postoperative complications compared with the emergency group (61.00 ± 43.70 vs. 121.18 ± 85.90 ml, P stent group was significantly longer than that in the emergency group (53 vs. 41 months, P = 0.034). In subgroup analysis of stent group, the stent laparoscopy group had significantly decreased postoperative complications (P = 0.025), and similar long-term survival (P = 0.81). Stent placement as a bridge to surgery is a safe and feasible procedure and provides significant advantages in terms of short-term outcomes and favorable prognoses for patients with AMCOs. Laparoscopic surgery could be considered as an optimal treatment after stent placement.

  6. Management of acute malignant colorectal obstruction with a novel self-expanding metallic stent as a bridge to surgery

    Energy Technology Data Exchange (ETDEWEB)

    Li Yongdong [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China); Cheng Yingsheng [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China); Department of Radiology, Tenth Affiliated People' s Hospital, Shanghai Tong Ji University, No. 301, Middle Yan Chang Road, Shanghai 200072 (China)], E-mail: chengys@sh163.net; Li Minghua [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China); Fan Youben; Chen Niwei; Wang Yu [Department of Gastroenterology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University (China); Zhao Jungong [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China)

    2010-03-15

    Purpose: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) in the treatment of patients with acute malignant colorectal obstruction. Methods: Between April 2001 and October 2007, 52 patients with acute malignant colorectal obstruction were treated with a new designed SEMS as an investigational bridge to surgery. Patients were prospectively followed and relevant data collection was collected, including details regarding technique, clinical symptoms, complications, need for elective surgery, and overall survival. Results: Stent placement was technically successful in all but two patients (due to complete obstruction) with no procedure-related complications. Complications included stent migration (n = 4), anal pain (n = 2) and stool impaction (n = 1). Clinical success was achieved in 49 (98%) of 50 patients with resolution of bowel obstruction within 2 days of stent placement. In one patient with stool impaction 2 days after stent placement, endoscopic disimpaction was successfully performed. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS as a bridge to surgery within a mean of 8 {+-} 2 days (range: 4-11 days) after stent placement. Mean follow-up time was 36 {+-} 12 months (range 3-70 months), and all patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement as a bridge to surgery was a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction and allowed a high proportion of patients to be successfully proceeded to elective surgery.

  7. Comparison between gastrostomy feeding and self-expandable metal stent insertion for patients with esophageal cancer and dysphagia.

    Directory of Open Access Journals (Sweden)

    Yang Won Min

    Full Text Available Self-expandable metal stent (SEMS insertion and percutaneous gastrostomy (PG feeding are commonly used for patients with esophageal cancer and dysphagia. This study aimed to compare outcomes between SEMS insertion and PG feeding for them.We retrospectively analyzed 308 patients with esophageal cancer who underwent fully covered SEMS insertion (stent group or PG (gastrostomy group for dysphagia due to tumor. Patients with other causes of dysphagia, such as radiation-induced or postoperative stricture, were excluded from the study. Clinical outcomes were compared between the two groups, including overall survival and need for additional intervention and postprocedural nutritional status.At baseline, the stent group (n = 169 had more stage IV patients, less cervical cancers, and received radiotherapy and esophagectomy less often than the gastrostomy group (n = 64. The Kaplan-Meier curves showed higher overall survival in the gastrostomy group than in the stent group. Multivariate analysis revealed that PG was associated with better survival compared with SEMS insertion (hazard ratio 0.541, 95% confidence interval 0.346-0.848, p = 0.007. In addition, the gastrostomy group needed additional intervention less often (3.1% vs. 21.9%, p < 0.001 and experienced less decrease in serum albumin levels (-0.15 ± 0.56 g/dL vs. -0.39 ± 0.58 g/dL, p = 0.011 than the stent group after procedure.Our data suggested that, compared with SEMS insertion, PG is associated with better overall survival in patients with esophageal cancer and dysphagia. Stabilized nutritional status by PG may play a role in improving patient survival.

  8. Nonlinear stability control and λ-bifurcation

    International Nuclear Information System (INIS)

    Erneux, T.; Reiss, E.L.; Magnan, J.F.; Jayakumar, P.K.

    1987-01-01

    Passive techniques for nonlinear stability control are presented for a model of fluidelastic instability. They employ the phenomena of λ-bifurcation and a generalization of it. λ-bifurcation occurs when a branch of flutter solutions bifurcates supercritically from a basic solution and terminates with an infinite period orbit at a branch of divergence solutions which bifurcates subcritically from the basic solution. The shape of the bifurcation diagram then resembles the greek letter λ. When the system parameters are in the range where flutter occurs by λ-bifurcation, then as the flow velocity increase the flutter amplitude also increases, but the frequencies of the oscillations decrease to zero. This diminishes the damaging effects of structural fatigue by flutter, and permits the flow speed to exceed the critical flutter speed. If generalized λ-bifurcation occurs, then there is a jump transition from the flutter states to a divergence state with a substantially smaller amplitude, when the flow speed is sufficiently larger than the critical flutter speed

  9. Recent perspective on coronary artery bifurcation interventions.

    Science.gov (United States)

    Dash, Debabrata

    2014-01-01

    Coronary bifurcation lesions are frequent in routine practice, accounting for 15-20% of all lesions undergoing percutaneous coronary intervention (PCI). PCI of this subset of lesions is technically challenging and historically has been associated with lower procedural success rates and worse clinical outcomes compared with non-bifurcation lesions. The introduction of drug-eluting stents has dramatically improved the outcomes. The provisional technique of implanting one stent in the main branch remains the default approach in most bifurcation lesions. Selection of the most effective technique for an individual bifurcation is important. The use of two-stent techniques as an intention to treat is an acceptable approach in some bifurcation lesions. However, a large amount of metal is generally left unapposed in the lumen with complex two-stent techniques, which is particularly concerning for the risk of stent thrombosis. New technology and dedicated bifurcation stents may overcome some of the limitations of two-stent techniques and revolutionise the management of bifurcation PCI in the future.

  10. Sixth International Symposium on Bifurcations and Instabilities in Fluid Dynamics (BIFD2015)

    DEFF Research Database (Denmark)

    Bar-Yoseph, P. Z.; Brøns, Morten; Gelfgat, A.

    2016-01-01

    dynamics and remain a challenge for experimental, theoretical and computational studies. Examples of prototypical hydrodynamic instabilities are the Rayleigh–Bénard, Taylor–Couette, Bénard–Marangoni, Rayleigh–Taylor, and Kelvin–Helmholtz instabilities. A fundamental understanding of bifurcation patterns...... diseases, such as atherosclerotic and vulnerable plaques, abdominal aortic aneurisms, carotid artery disease, and pulmonary embolisms and implications for vascular interventions such as grafting and stenting. The collection of papers in this issue is a selection of the presentations given at the Sixth...

  11. Quantum entanglement and fixed-point bifurcations

    International Nuclear Information System (INIS)

    Hines, Andrew P.; McKenzie, Ross H.; Milburn, G.J.

    2005-01-01

    How does the classical phase-space structure for a composite system relate to the entanglement characteristics of the corresponding quantum system? We demonstrate how the entanglement in nonlinear bipartite systems can be associated with a fixed-point bifurcation in the classical dynamics. Using the example of coupled giant spins we show that when a fixed point undergoes a supercritical pitchfork bifurcation, the corresponding quantum state--the ground state--achieves its maximum amount of entanglement near the critical point. We conjecture that this will be a generic feature of systems whose classical limit exhibits such a bifurcation

  12. A case study in bifurcation theory

    Science.gov (United States)

    Khmou, Youssef

    This short paper is focused on the bifurcation theory found in map functions called evolution functions that are used in dynamical systems. The most well-known example of discrete iterative function is the logistic map that puts into evidence bifurcation and chaotic behavior of the topology of the logistic function. We propose a new iterative function based on Lorentizan function and its generalized versions, based on numerical study, it is found that the bifurcation of the Lorentzian function is of second-order where it is characterized by the absence of chaotic region.

  13. Bifurcations of non-smooth systems

    Science.gov (United States)

    Angulo, Fabiola; Olivar, Gerard; Osorio, Gustavo A.; Escobar, Carlos M.; Ferreira, Jocirei D.; Redondo, Johan M.

    2012-12-01

    Non-smooth systems (namely piecewise-smooth systems) have received much attention in the last decade. Many contributions in this area show that theory and applications (to electronic circuits, mechanical systems, …) are relevant to problems in science and engineering. Specially, new bifurcations have been reported in the literature, and this was the topic of this minisymposium. Thus both bifurcation theory and its applications were included. Several contributions from different fields show that non-smooth bifurcations are a hot topic in research. Thus in this paper the reader can find contributions from electronics, energy markets and population dynamics. Also, a carefully-written specific algebraic software tool is presented.

  14. Bifurcation Control of Chaotic Dynamical Systems

    National Research Council Canada - National Science Library

    Wang, Hua O; Abed, Eyad H

    1992-01-01

    A nonlinear system which exhibits bifurcations, transient chaos, and fully developed chaos is considered, with the goal of illustrating the role of two ideas in the control of chaotic dynamical systems...

  15. Bifurcation and instability problems in vortex wakes

    DEFF Research Database (Denmark)

    Aref, Hassan; Brøns, Morten; Stremler, Mark A.

    2007-01-01

    A number of instability and bifurcation problems related to the dynamics of vortex wake flows are addressed using various analytical tools and approaches. We discuss the bifurcations of the streamline pattern behind a bluff body as a vortex wake is produced, a theory of the universal Strouhal......-Reynolds number relation for vortex wakes, the bifurcation diagram for "exotic" wake patterns behind an oscillating cylinder first determined experimentally by Williamson & Roshko, and the bifurcations in topology of the streamlines pattern in point vortex streets. The Hamiltonian dynamics of point vortices...... in a periodic strip is considered. The classical results of von Kármán concerning the structure of the vortex street follow from the two-vortices-in-a-strip problem, while the stability results follow largely from a four-vortices-in-a-strip analysis. The three-vortices-in-a-strip problem is argued...

  16. Bifurcation structure of successive torus doubling

    International Nuclear Information System (INIS)

    Sekikawa, Munehisa; Inaba, Naohiko; Yoshinaga, Tetsuya; Tsubouchi, Takashi

    2006-01-01

    The authors discuss the 'embryology' of successive torus doubling via the bifurcation theory, and assert that the coupled map of a logistic map and a circle map has a structure capable of generating infinite number of torus doublings

  17. Self-expandable metal stent for palliation of malignant dysphagia & quality of life improvement in advanced cancer esophagus: Upper Egypt experience

    OpenAIRE

    Mohamed Abdelshafy; Mohammed A. Omar; Mohamed Abdel Bary; Mohamed Mostafa Wahaman; Rafaat Abd elaal Bakheet

    2017-01-01

    Background: In advanced cancer esophagus patients, self-expandable metallic stents (SEMS) are utilized to relieve malignant difficulty in swallowing and improve their quality of the life. Retrospectively, we evaluated the efficacy, feasibility, and outcomes of SEMS in palliation of malignant dysphagia in advanced cancer esophagus and its' complications. Methods: We retrospectively reviewed data of 350 patients with malignant dysphagia due to advanced cancer esophagus from December 2012 to ...

  18. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self-expanding

  19. Clinical benefits and oncologic equivalence of self-expandable metallic stent insertion for right-sided malignant colonic obstruction.

    Science.gov (United States)

    Ji, Woong Bae; Kwak, Jung Myun; Kang, Dong Woo; Kwak, Han Deok; Um, Jun Won; Lee, Sun-Il; Min, Byung-Wook; Sung, Nak Song; Kim, Jin; Kim, Seon Hahn

    2017-01-01

    The efficacy of stenting for right-sided malignant colonic obstruction is unknown. This study aimed to evaluate the safety, feasibility, and clinical benefits of self-expandable metallic stent insertion for right-sided malignant colonic obstruction. Clinical data from patients who underwent right hemicolectomy for right colon cancer from January 2006 to July 2014 at three Korea University hospitals were retrospectively reviewed. A total of 39 patients who developed malignant obstruction in the right-sided colon were identified, and their data were analyzed. Stent insertion was attempted in 16 patients, and initial technical success was achieved in 14 patients (87.5 %). No stent-related immediate complications were reported. Complete relief from obstruction was achieved in all 14 patients. Twenty-five patients, including two patients who failed stenting, underwent emergency surgery. In the stent group, 93 % (13/14) of patients underwent elective laparoscopic surgery, and only one surgery was converted to an open procedure. All patients in the emergency group underwent emergency surgery within 24 h of admission. In the emergency group, only 12 % (3/25) of patients underwent laparoscopic surgery, with one surgery converted to an open procedure. All patients in both groups underwent either laparoscopy-assisted or open right/extended right hemicolectomy with primary anastomoses as the first operation. The operative times, retrieved lymph nodes, and pathologic stage did not differ between the two groups. Postoperative hospital stay (9.4 ± 3.4 days in the stent group vs. 12.4 ± 5.9 in the emergency group, p = 0.089) and time to resume oral food intake (3.2 ± 2.1 days in the stent group vs. 5.7 ± 3.4 in the emergency group, p = 0.019) were shorter in the stent group. And there were no significant differences in disease-free survival and overall survival between the two groups. Stent insertion appears to be safe and feasible in patients with right

  20. Self-expandable metallic stent placement for patients with inoperable esophageal carcinoma. Investigation of the influence of prior radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Ihara, Yuko; Murayama, Sadayuki; Toita, Takafumi; Utsunomiya, Takashi; Nagata, Osamu; Akamine, Tamaki; Ogawa, Kazuhiko; Adachi, Genki; Tanigawa, Noboru

    2006-01-01

    The aim of this study was to evaluate the efficacy and complications of self-expandable metallic stent placement for patients with inoperable esophageal carcinoma after radiotherapy and/or chemotherapy. We obtained data from 19 patients with advanced or recurrent esophageal carcinoma between 1996 and 2000. In all patients, a self-expandable metallic stent was placed under fluoroscopic guidance. Dysphagia before and after stent placement was graded. Complications after stent placement were also evaluated. Data were compared between patients with and without prior radiotherapy and/or chemotherapy. The procedure was technically successful in all but one patient. The dysphagia grade improved in all patients. No life-threatening complications occurred. The other major complications such as mediastinitis occurred in two patients, and pneumonia and funnel phenomenon occurred in one patient each. These patients had a history of radiotherapy and/or chemotherapy prior to stent placement. Eight of the twelve patients with prior radiotherapy and/or chemotherapy compared with one of seven patients without prior therapy had persistent chest pain, which was a statistically significant difference (P<0.05). Placement of self-expandable metallic stents was effective for patients with advanced or recurrent esophageal carcinoma. However, prior irradiation and/or chemotherapy increased the risk of persistent chest pain after stent placement. (author)

  1. Hopf bifurcation in an Internet congestion control model

    International Nuclear Information System (INIS)

    Li Chunguang; Chen Guanrong; Liao Xiaofeng; Yu Juebang

    2004-01-01

    We consider an Internet model with a single link accessed by a single source, which responds to congestion signals from the network, and study bifurcation of such a system. By choosing the gain parameter as a bifurcation parameter, we prove that Hopf bifurcation occurs. The stability of bifurcating periodic solutions and the direction of the Hopf bifurcation are determined by applying the normal form theory and the center manifold theorem. Finally, a numerical example is given to verify the theoretical analysis

  2. Discretization analysis of bifurcation based nonlinear amplifiers

    Science.gov (United States)

    Feldkord, Sven; Reit, Marco; Mathis, Wolfgang

    2017-09-01

    Recently, for modeling biological amplification processes, nonlinear amplifiers based on the supercritical Andronov-Hopf bifurcation have been widely analyzed analytically. For technical realizations, digital systems have become the most relevant systems in signal processing applications. The underlying continuous-time systems are transferred to the discrete-time domain using numerical integration methods. Within this contribution, effects on the qualitative behavior of the Andronov-Hopf bifurcation based systems concerning numerical integration methods are analyzed. It is shown exemplarily that explicit Runge-Kutta methods transform the truncated normalform equation of the Andronov-Hopf bifurcation into the normalform equation of the Neimark-Sacker bifurcation. Dependent on the order of the integration method, higher order terms are added during this transformation.A rescaled normalform equation of the Neimark-Sacker bifurcation is introduced that allows a parametric design of a discrete-time system which corresponds to the rescaled Andronov-Hopf system. This system approximates the characteristics of the rescaled Hopf-type amplifier for a large range of parameters. The natural frequency and the peak amplitude are preserved for every set of parameters. The Neimark-Sacker bifurcation based systems avoid large computational effort that would be caused by applying higher order integration methods to the continuous-time normalform equations.

  3. Simultaneous rota-stenting and transcatheter aortic valve implantation for patients with heavily calcified coronary stenosis and aortic stenosis

    Directory of Open Access Journals (Sweden)

    Yung-Tsai Lee

    2016-09-01

    Full Text Available Given that coronary artery disease (CAD in octogenarians undergoing transcatheter aortic valve implantation (TAVI often presents with more complex lesions and extensive calcification, rotational atherectomy (RA may be needed in some cases before stenting. However, data regarding the feasibility and safety of simultaneous RA during TAVI using the Medtronic CoreValve (MCV; Medtronic, Minneapolis, MN, USA system are lacking. Three out of 107 (2.8% patients (2 females, average age 85.6 years, mean aortic valve area 0.5 cm2, mean left ventricular ejection fraction 39%, mean Logistic EuroScore 70%, with complex, heavily calcified coronary stenosis, and severe valvular aortic stenosis (AS were treated with TAVI and RA due to high surgical risk. After balloon valvuloplasty, all coronary lesions were successfully treated with RA and stenting, immediately followed by transfemoral TAVI with a self-expandable MCV. Our data suggested that in the very elderly patients with severe and heavily calcified CAD and AS who were turned down for cardiac surgery, RA and stenting followed by TAVI may be performed successfully in a combined, single-stage procedure.

  4. Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

    Science.gov (United States)

    Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz

    2018-05-24

    The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Geometrically Induced Interactions and Bifurcations

    Science.gov (United States)

    Binder, Bernd

    2010-01-01

    In order to evaluate the proper boundary conditions in spin dynamics eventually leading to the emergence of natural and artificial solitons providing for strong interactions and potentials with monopole charges, the paper outlines a new concept referring to a curvature-invariant formalism, where superintegrability is given by a special isometric condition. Instead of referring to the spin operators and Casimir/Euler invariants as the generator of rotations, a curvature-invariant description is introduced utilizing a double Gudermann mapping function (generator of sine Gordon solitons and Mercator projection) cross-relating two angular variables, where geometric phases and rotations arise between surfaces of different curvature. Applying this stereographic projection to a superintegrable Hamiltonian can directly map linear oscillators to Kepler/Coulomb potentials and/or monopoles with Pöschl-Teller potentials and vice versa. In this sense a large scale Kepler/Coulomb (gravitational, electro-magnetic) wave dynamics with a hyperbolic metric could be mapped as a geodesic vertex flow to a local oscillator singularity (Dirac monopole) with spherical metrics and vice versa. Attracting fixed points and dynamic constraints are given by special isometries with magic precession angles. The nonlinear angular encoding directly provides for a Shannon mutual information entropy measure of the geodesic phase space flow. The emerging monopole patterns show relations to spiral Fresnel holography and Berry/Aharonov-Bohm geometric phases subject to bifurcation instabilities and singularities from phase ambiguities due to a local (entropy) overload. Neutral solitons and virtual patterns emerging and mediating in the overlap region between charged or twisted holographic patterns are visualized and directly assigned to the Berry geometric phase revealing the role of photons, neutrons, and neutrinos binding repulsive charges in Coulomb, strong and weak interaction.

  6. Simple or Complex Stenting for Bifurcation Coronary Lesions: A Patient-Level Pooled-Analysis of the Nordic Bifurcation Study and the British Bifurcation Coronary Study

    DEFF Research Database (Denmark)

    Behan, Miles W; Holm, Niels Ramsing; Curzen, Nicholas P

    2011-01-01

    Background— Controversy persists regarding the correct strategy for bifurcation lesions. Therefore, we combined the patient-level data from 2 large trials with similar methodology: the NORDIC Bifurcation Study (NORDIC I) and the British Bifurcation Coronary Study (BBC ONE). Methods and Results— B...

  7. Plastic vs. Self-Expandable Metal Stents for Palliation in Malignant Biliary Obstruction: A Series of Meta-Analyses.

    Science.gov (United States)

    Almadi, Majid A; Barkun, Alan; Martel, Myriam

    2017-02-01

    Self-expandable metal stents (SEMS) are thought to have an advantage over plastic stents in achieving biliary drainage. We performed a systematic search of MEDLINE, EMBASE, Scopus, CENTRAL, and ISI Web of knowledge databases, from January 1980 to September 2015, for randomized-controlled trials (RCTs) comparing SEMS vs. plastic stents in the palliation of malignant biliary obstruction. Primary outcomes were durations of stent patency, patient survival, and 30-day mortality. Numerous secondary outcomes were assessed, and extensive sensitivity and subgroup analyses were performed. In all, 20 RCTs totaling 1,713 patients yielded a weighted mean difference (WMD) in time to stent patency (4 studies) of 4.45 months (95% confidence interval (CI), 0.31, 8.59; GRADE=moderate) favoring SEMS. There were no differences in overall patient survival (5 studies) WMD=0.67 months (95% CI, -0.66, 1.99; GRADE=moderate), or 30-day mortality (8 studies) odds ratio (OR)=0.80 (95% CI, 0.52, 1.24; GRADE=moderate) but there was a higher symptom-free survival at 6 months (4 studies) OR=5.96 (95% CI, 1.71, 20.81; GRADE=moderate). SEMS use resulted in lower rates of late complications (11 studies) OR=0.43 (95% CI, 0.26, 0.71; GRADE=moderate), sepsis or cholangitis (14 studies) OR=0.53 (95% CI, 0.37, 0.77; GRADE=high), blocking from sludge (8 studies) OR=0.11(95% CI, 0.07, 0.17; GRADE=moderate), and mean number of re-interventions (8 studies) WMD=-0.83 interventions (95% CI, -1.64, -0.02; GRADE=moderate). There was a longer patency of SEMS for those without a prior drainage attempt (2 studies) WMD 7.70 months (95% CI, 7.14, 8.25; GRADE=high). Although a survival advantage was found when an uncovered SEMS was used (3 studies) WMD 1.31 months (95% CI, 0.30, 2.32; GRADE=high), but not partially or fully covered SEMS (2 studies) WMD -0.66 months (95% CI, -1.02, -0.30; GRADE=high) vs. plastic stents, and for SEMS in the setting of pre- or post-procedural antibiotic administration (2 studies) WMD 1

  8. Bifurcation analysis of a three dimensional system

    Directory of Open Access Journals (Sweden)

    Yongwen WANG

    2018-04-01

    Full Text Available In order to enrich the stability and bifurcation theory of the three dimensional chaotic systems, taking a quadratic truncate unfolding system with the triple singularity equilibrium as the research subject, the existence of the equilibrium, the stability and the bifurcation of the system near the equilibrium under different parametric conditions are studied. Using the method of mathematical analysis, the existence of the real roots of the corresponding characteristic equation under the different parametric conditions is analyzed, and the local manifolds of the equilibrium are gotten, then the possible bifurcations are guessed. The parametric conditions under which the equilibrium is saddle-focus are analyzed carefully by the Cardan formula. Moreover, the conditions of codimension-one Hopf bifucation and the prerequisites of the supercritical and subcritical Hopf bifurcation are found by computation. The results show that the system has abundant stability and bifurcation, and can also supply theorical support for the proof of the existence of the homoclinic or heteroclinic loop connecting saddle-focus and the Silnikov's chaos. This method can be extended to study the other higher nonlinear systems.

  9. Bifurcations of Tumor-Immune Competition Systems with Delay

    Directory of Open Access Journals (Sweden)

    Ping Bi

    2014-01-01

    Full Text Available A tumor-immune competition model with delay is considered, which consists of two-dimensional nonlinear differential equation. The conditions for the linear stability of the equilibria are obtained by analyzing the distribution of eigenvalues. General formulas for the direction, period, and stability of the bifurcated periodic solutions are given for codimension one and codimension two bifurcations, including Hopf bifurcation, steady-state bifurcation, and B-T bifurcation. Numerical examples and simulations are given to illustrate the bifurcations analysis and obtained results.

  10. Aortic arch malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kellenberger, Christian J. [University Children' s Hospital, Department of Diagnostic Imaging, Zuerich (Switzerland)

    2010-06-15

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  11. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  12. Aortic arch malformations

    International Nuclear Information System (INIS)

    Kellenberger, Christian J.

    2010-01-01

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  13. Imaging in aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.).

  14. Attractors near grazing–sliding bifurcations

    International Nuclear Information System (INIS)

    Glendinning, P; Kowalczyk, P; Nordmark, A B

    2012-01-01

    In this paper we prove, for the first time, that multistability can occur in three-dimensional Fillipov type flows due to grazing–sliding bifurcations. We do this by reducing the study of the dynamics of Filippov type flows around a grazing–sliding bifurcation to the study of appropriately defined one-dimensional maps. In particular, we prove the presence of three qualitatively different types of multiple attractors born in grazing–sliding bifurcations. Namely, a period-two orbit with a sliding segment may coexist with a chaotic attractor, two stable, period-two and period-three orbits with a segment of sliding each may coexist, or a non-sliding and period-three orbit with two sliding segments may coexist

  15. Y-shaped bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction: data from a referral center for palliative care.

    Science.gov (United States)

    Di Mitri, R; Mocciaro, F

    2014-01-01

    Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Twenty patients (9 males) were treated (mean age 64.2 ± 15.3 years). The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%), IIIa in 1 (5%), and IV in 14 (70%). The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL). One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months), 13 of the 20 patients (65%) had died. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration) as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  16. Y-Shaped Bilateral Self-Expandable Metallic Stent Placement for Malignant Hilar Biliary Obstruction: Data from a Referral Center for Palliative Care

    Directory of Open Access Journals (Sweden)

    R. Di Mitri

    2014-01-01

    Full Text Available Background and Aim. Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. Methods. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Results. Twenty patients (9 males were treated (mean age 64.2 ± 15.3 years. The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%, IIIa in 1 (5%, and IV in 14 (70%. The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL. One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months, 13 of the 20 patients (65% had died. Conclusions. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  17. A Novel Self-Expandable, Radioactive Airway Stent Loaded with 125I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

    Science.gov (United States)

    Wang, Yong; Guo, Jin-He; Zhu, Guang-Yu; Zhu, Hai-Dong; Chen, Li; Lu, Jian; Wang, Chao; Teng, Gao-Jun

    2017-07-01

    Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with 125 I seeds in healthy beagle dog. Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with 125 I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting. All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of 125 I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope. This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with 125 I seeds in healthy beagle dog.

  18. Bifurcation structure of parameter plane for a family of unimodal piecewise smooth maps: Border-collision bifurcation curves

    International Nuclear Information System (INIS)

    Sushko, Iryna; Agliari, Anna; Gardini, Laura

    2006-01-01

    We study the structure of the 2D bifurcation diagram for a two-parameter family of piecewise smooth unimodal maps f with one break point. Analysing the parameters of the normal form for the border-collision bifurcation of an attracting n-cycle of the map f, we describe the possible kinds of dynamics associated with such a bifurcation. Emergence and role of border-collision bifurcation curves in the 2D bifurcation plane are studied. Particular attention is paid also to the curves of homoclinic bifurcations giving rise to the band merging of pieces of cyclic chaotic intervals

  19. Retrieval of a self-expanding metal stent after migration and incorporation in the omental bursa, using a gastroscopic-transgastric laparoscopic rendezvous technique.

    Science.gov (United States)

    Patrzyk, Maciej; Dierzek, Przemyslaw; Glitsch, Anne; Paul, Hartmut; Heidecke, Claus-Dieter

    2015-01-01

    Endoscopic drainage is a widely used treatment for pancreatic pseudocysts. Drainage-related complications may be related directly to the procedure or may occur later as stents migrate or erode into adjacent structures. Migration of a self-expanding metal stent into peritoneal cavity and incorporation in the omental bursa is rare. When endoscopic retrieval fails a combined laparoscopic-endoscopic (rendezvous technique) approach offers an alternative to open surgery. We report a case of successful gastroscopic-transgastric laparoscopic removal of a stent that was dislocated into the omental bursa after a ½ year observation period.

  20. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo

    DEFF Research Database (Denmark)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo

    2017-01-01

    implants each for 2 and 3½ weeks, respectively. Results  In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all......  A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures....

  1. Retrieval of a self-expanding metal stent after migration and incorporation in the omental bursa, using a gastroscopic-transgastric laparoscopic rendezvous technique

    Directory of Open Access Journals (Sweden)

    Maciej Patrzyk

    2015-01-01

    Full Text Available Endoscopic drainage is a widely used treatment for pancreatic pseudocysts. Drainage-related complications may be related directly to the procedure or may occur later as stents migrate or erode into adjacent structures. Migration of a self-expanding metal stent into peritoneal cavity and incorporation in the omental bursa is rare. When endoscopic retrieval fails a combined laparoscopic-endoscopic (rendezvous technique approach offers an alternative to open surgery. We report a case of successful gastroscopic-transgastric laparoscopic removal of a stent that was dislocated into the omental bursa after a ΍ year observation period.

  2. Bifurcation of Jovian magnetotail current sheet

    Directory of Open Access Journals (Sweden)

    P. L. Israelevich

    2006-07-01

    Full Text Available Multiple crossings of the magnetotail current sheet by a single spacecraft give the possibility to distinguish between two types of electric current density distribution: single-peaked (Harris type current layer and double-peaked (bifurcated current sheet. Magnetic field measurements in the Jovian magnetic tail by Voyager-2 reveal bifurcation of the tail current sheet. The electric current density possesses a minimum at the point of the Bx-component reversal and two maxima at the distance where the magnetic field strength reaches 50% of its value in the tail lobe.

  3. Bifurcation of Jovian magnetotail current sheet

    Directory of Open Access Journals (Sweden)

    P. L. Israelevich

    2006-07-01

    Full Text Available Multiple crossings of the magnetotail current sheet by a single spacecraft give the possibility to distinguish between two types of electric current density distribution: single-peaked (Harris type current layer and double-peaked (bifurcated current sheet. Magnetic field measurements in the Jovian magnetic tail by Voyager-2 reveal bifurcation of the tail current sheet. The electric current density possesses a minimum at the point of the Bx-component reversal and two maxima at the distance where the magnetic field strength reaches 50% of its value in the tail lobe.

  4. Bovine aortic arch with supravalvular aortic stenosis.

    Science.gov (United States)

    Idhrees, Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, K

    2016-09-01

    A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS). On evaluation of CT angiogram, there was associated bovine aortic arch (BAA). Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  5. Bovine aortic arch with supravalvular aortic stenosis

    Directory of Open Access Journals (Sweden)

    Mohammed Idhrees

    2016-09-01

    Full Text Available A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS. On evaluation of CT angiogram, there was associated bovine aortic arch (BAA. Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA.

  6. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Transcatheter aortic-valve implantation with one single minimal contrast media injection.

    Science.gov (United States)

    Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian

    2015-06-01

    Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.

  8. Discretizing the transcritical and pitchfork bifurcations – conjugacy results

    KAUST Repository

    Ló czi, Lajos

    2015-01-01

    © 2015 Taylor & Francis. We present two case studies in one-dimensional dynamics concerning the discretization of transcritical (TC) and pitchfork (PF) bifurcations. In the vicinity of a TC or PF bifurcation point and under some natural assumptions

  9. Bifurcations of a class of singular biological economic models

    International Nuclear Information System (INIS)

    Zhang Xue; Zhang Qingling; Zhang Yue

    2009-01-01

    This paper studies systematically a prey-predator singular biological economic model with time delay. It shows that this model exhibits two bifurcation phenomena when the economic profit is zero. One is transcritical bifurcation which changes the stability of the system, and the other is singular induced bifurcation which indicates that zero economic profit brings impulse, i.e., rapid expansion of the population in biological explanation. On the other hand, if the economic profit is positive, at a critical value of bifurcation parameter, the system undergoes a Hopf bifurcation, i.e., the increase of delay destabilizes the system and bifurcates into small amplitude periodic solution. Finally, by using Matlab software, numerical simulations illustrate the effectiveness of the results obtained here. In addition, we study numerically that the system undergoes a saddle-node bifurcation when the bifurcation parameter goes through critical value of positive economic profit.

  10. Bifurcation structure of a model of bursting pancreatic cells

    DEFF Research Database (Denmark)

    Mosekilde, Erik; Lading, B.; Yanchuk, S.

    2001-01-01

    One- and two-dimensional bifurcation studies of a prototypic model of bursting oscillations in pancreatic P-cells reveal a squid-formed area of chaotic dynamics in the parameter plane, with period-doubling bifurcations on one side of the arms and saddle-node bifurcations on the other. The transit......One- and two-dimensional bifurcation studies of a prototypic model of bursting oscillations in pancreatic P-cells reveal a squid-formed area of chaotic dynamics in the parameter plane, with period-doubling bifurcations on one side of the arms and saddle-node bifurcations on the other....... The transition from this structure to the so-called period-adding structure is found to involve a subcritical period-doubling bifurcation and the emergence of type-III intermittency. The period-adding transition itself is not smooth but consists of a saddle-node bifurcation in which (n + 1)-spike bursting...

  11. Codimension-2 bifurcations of the Kaldor model of business cycle

    International Nuclear Information System (INIS)

    Wu, Xiaoqin P.

    2011-01-01

    Research highlights: → The conditions are given such that the characteristic equation may have purely imaginary roots and double zero roots. → Purely imaginary roots lead us to study Hopf and Bautin bifurcations and to calculate the first and second Lyapunov coefficients. → Double zero roots lead us to study Bogdanov-Takens (BT) bifurcation. → Bifurcation diagrams for Bautin and BT bifurcations are obtained by using the normal form theory. - Abstract: In this paper, complete analysis is presented to study codimension-2 bifurcations for the nonlinear Kaldor model of business cycle. Sufficient conditions are given for the model to demonstrate Bautin and Bogdanov-Takens (BT) bifurcations. By computing the first and second Lyapunov coefficients and performing nonlinear transformation, the normal forms are derived to obtain the bifurcation diagrams such as Hopf, homoclinic and double limit cycle bifurcations. Some examples are given to confirm the theoretical results.

  12. The JUPITER registry: 1-year results of transapical aortic valve implantation using a second-generation transcatheter heart valve in patients with aortic stenosis.

    Science.gov (United States)

    Silaschi, Miriam; Treede, Hendrik; Rastan, Ardawan J; Baumbach, Hardy; Beyersdorf, Friedhelm; Kappert, Utz; Eichinger, Walter; Rüter, Florian; de Kroon, Thomas L; Lange, Rüdiger; Ensminger, Stephan; Wendler, Olaf

    2016-11-01

    Transcatheter aortic valve replacement (TAVR) is an established therapy for patients with aortic stenosis (AS) at high surgical risk. The JenaValve™ is a second-generation, self-expanding transcatheter heart valve (THV), implanted through transapical access (TA). During stent deployment, a specific 'clipping-mechanism' engages native aortic valve cusps for fixation. We present 1-year outcomes of the JUPITER registry, a post-market registry of the JenaValve for TA-TAVR. The JUPITER registry is a prospective, multicentre, uncontrolled and observational European study to evaluate the long-term safety and effectiveness of the Conformité Européenne-marked JenaValve THV. A total of 180 patients with AS were enrolled between 2012 and 2014. End-points were adjudicated in accordance with the valve academic research consortium document no. 1 definitions. The mean age was 80.4 ± 5.9 years and the mean logistic European system for cardiac operative risk evaluation I 21.2 ± 14.7%. The procedure was successful in 95.0% (171/180), implantation of a second THV (valve-in-valve) was performed in 2.2% (4/180) and conversion to surgical aortic valve replacement (SAVR) was necessary in 2.8% (5/180). No annular rupture or coronary ostia obstruction occurred. Two patients required SAVR after the day of index procedure (1.1%). All-cause mortality at 30 days was 11.1% (20/180), being cardiovascular in 7.2% (13/180). A major stroke occurred in 1.1% (2/180) at 30 days, no additional major strokes were observed during 1 year. All-cause mortality after 30 days was 13.1% (21/160) and combined efficacy at 1 year was 80.8% (122/151). At 1-year follow-up, no patient presented with more than moderate paravalvular leakage, while 2 patients (3.2%) showed moderate, 12 (19.0%) mild and 49 (82.4%) trace/none paravalvular regurgitation. In a high-risk cohort of patients undergoing TA-TAVR for AS, the use of the JenaValve THV is safe and effective. In patients at higher risk for coronary ostia

  13. Comments on the Bifurcation Structure of 1D Maps

    DEFF Research Database (Denmark)

    Belykh, V.N.; Mosekilde, Erik

    1997-01-01

    -within-a-box structure of the total bifurcation set. This presents a picture in which the homoclinic orbit bifurcations act as a skeleton for the bifurcational set. At the same time, experimental results on continued subharmonic generation for piezoelectrically amplified sound waves, predating the Feigenbaum theory......, are called into attention....

  14. NUMERICAL HOPF BIFURCATION OF DELAY-DIFFERENTIAL EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this paper we consider the numerical solution of some delay differential equations undergoing a Hopf bifurcation. We prove that if the delay differential equations have a Hopf bifurcation point atλ=λ*, then the numerical solution of the equation also has a Hopf bifurcation point atλh =λ* + O(h).

  15. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    Energy Technology Data Exchange (ETDEWEB)

    Løvdal, Alexandra Liv Vest, E-mail: alvlo@nanotech.dtu.dk [Technical University of Denmark, Department of Micro- and Nanotechnology (Denmark); Calve, Sarah [Purdue University, Weldon School of Biomedical Engineering (United States); Yang, Shuo; Alstine, William Van [Cook Research Incorporated (United States); Binkert, Christoph A. [Institut für Radiologie, Kantonsspital Winterthur (Switzerland); Klausen, Kasper [William Cook Europe (Denmark)

    2017-01-15

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  16. How to design the optimal self-expandable oesophageal metallic stents: 22 years of experience in 645 patients with malignant strictures.

    Science.gov (United States)

    Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Kang, Min Kyoung; Lee, Jongjin; Oh, Se Jin

    2013-03-01

    To evaluate the clinical efficacy and safety of self-expandable metallic stent (SEMS) placement for malignant oesophageal strictures and their relationship with stent designs. Seven generations of SEMS were used to treat 645 consecutive patients with oesophageal strictures. Logistic regression models were constructed to identify predictive factors associated with complications. Stent placement was technically successful in 641 of 645 patients (99.4%). The clinical success rate was 95.5%. There were 260 (40.3%) complications after stent placement. Due to complications, 68 stents were removed; 66 of 68 stents (97.1%) were removed successfully. Stainless steel (SS) stents (odds ratio [OR] 4.18; 95% confidence interval [CI] 2.10, 8.32) and radiation therapy (RT) before stent placement (OR 4.23; CI 2.02, 8.83) were significantly associated with severe pain. Flared ends (OR 9.63; CI 3.38, 27.43), stricture length stent diameter stent migration. Polyurethane membranes were associated with more frequent tumour ingrowth than polytetrafluoroethylene (PTFE) membranes (P = 0.002). Despite the relatively high complication rate, retrievable self-expandable PTFE-covered nitinol stents equipped with a head and a tail appeared to be an effective treatment for malignant oesophageal strictures.

  17. Clinical feasibility of a new through-the-scope fully covered esophageal self-expandable metallic stent: an in vivo animal study.

    Science.gov (United States)

    Cheon, Young Koog; Lee, Tae Yoon; Sung, In Kyung; Shim, Chan Sup

    2014-01-01

    Most delivery devices used for esophageal stents for obstructing esophageal cancer have a diameter of 5-8 mm, a size that is too large to pass through the endoscopic working channel. The conventional esophageal stent requires multiple endoscopic procedures for implantation. The purpose of the present study was to evaluate the clinical feasibility of a newly developed fully covered, self-expanding, through-the-scope (TTS) esophageal stent in a porcine model. Eight mini pigs were used. Each animal underwent placement of a fully covered TTS stent (Hanarostent® Esophagus TTS) and the upper part of the stent was fixed by suturing with nylon. Fluoroscopy was carried out every week to assess migration of the stent. Follow-up endoscopy was done every month for 3 months to evaluate the status of the membrane, stent mesh, grade of tissue hyperplasia, and mucosal changes at both ends of the stent. All stents were successfully and easily deployed, and were placed without any distortion in the stent or without rupture of the membrane. In two cases, stent migration was observed after 8 weeks. No case of membrane disruption, stent mesh disruption or tissue hyperplasia at either end of the stent was found at the completion of the study. Our findings indicate that the new fully covered self-expanding TTS esophageal stent is easy and simple to implant, and no significant distortion of mesh or disruption of membrane was observed. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  18. [The application of Y-shaped self-expandable covered metal stents in the thoracostomach-airway fistula: a single center, 11 years experience].

    Science.gov (United States)

    Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming

    2015-08-01

    To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.

  19. A pilot study about the oncologic safety of colonic self-expandable metal stents (SEMS) in obstructive colon cancer: is occlusion always better than "silent" perforation?

    Science.gov (United States)

    Zanghì, A; Piccolo, G; Cavallaro, A; Pulvirenti, E; Lo Menzo, E; Cardì, F; Di Vita, M; Cappellani, A

    2016-12-01

    To evaluate the oncologic safety of colonic self-expandable metal stents (SEMS) in obstructive colon cancer. We retrospectively reviewed all the patients who were treated with endoscopic placement of a self-expandable metallic stent (SEMS) at our institution. A total of 26 patients were identified during the study period, of which 24 patients (92.30%) were treated with SEMS as a bridge-to-surgery and 2 (7.69%) as palliation. In 22 cases (80.76%), the stenosis was localized to the left side. Clinical success with resolution of bowel obstructions was achieved in 22 (84.61%) patients within a short period of time. Among patients treated successfully with SEMS insertion as bridge to surgery (n = 22), 20 (90.9%) underwent one-stage surgery with primary anastomosis while 2 patients (9.09%) underwent colostomy due to intraoperative evidence of a covered perforation by cancer tissue in the pelvis. Patients with subclinical perforation developed an early peritoneal carcinomatosis, 10 patients treated with curative intent subsequently developed liver metastasis after 24 months. We reported an overall poor outcome among patients treated with the insertion of SEMS. This led us to think that, in some cases, occlusion may be better than a "silent" perforation.

  20. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo.

    Science.gov (United States)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Van Alstine, William; Binkert, Christoph A; Klausen, Kasper

    2017-01-01

    This study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo. A diamond-shaped stent-base was cut from a sequential biaxially strained poly(L-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively. In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks. A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  1. Initial and mid-term results of a 4F compatible self-expanding low strut profile nitinol stent in the superficial femoral artery

    International Nuclear Information System (INIS)

    Muehlenbruch, G.; Brock, H.; Das, M.; Hohl, C.; Mahnken, A.H.; Wildberger, J.; Guenther, R.W.; Haage, P.

    2007-01-01

    Purpose: To evaluate the initial and mid-term results of a new self-expanding low strut profile nitinol stent for treatment of atherosclerotic lesions stenoses and occlusions in the superficial femoral artery (SFA). Materials and Methods: In 8 patients (4 male, 4 female, mean age 74.8 ± 8.8 years) with SFA lesions and non-satisfying results after PTA treatment alone, 10 self-expanding nitinol Xpert stents were deployed via a 4 F sheath. Stent characteristics and handling were graded by the interventionalist. Fontaine classification, duplex flow measurements and ankle brachial index (ABI) at rest and stress were taken prior and one day after stent placement. Patients were followed 3, 6 and 12 months after the procedure obtaining the same parameters at each appointment. Results: Initial stent treatment was successful in all patients. Stent handling and positioning were rated very good and safe. All patients improved clinically by at least one Fontaine stage (range before treatment: stage IIb to IV). The mean ABI at rest (stress) improved initially from 0.68 (0.70) to 1.07 (0.99). During a mean follow-up period of 8.3 months no case of clinically relevant in-stent stenosis was observed with stable values of ABI at rest and stress. (orig.)

  2. Complications related to conventional self-expandable metal stent insertion and internal irradiation stent insertion in patients with advanced esophageal carcinoma: an analysis of 32 cases

    International Nuclear Information System (INIS)

    Xu Xingwen; Di Haiting; Zhu Jun; Shi Jian

    2011-01-01

    Objective: To compare the occurrence of complications between conventional self-expandable metal stent and internal irradiation stent insertion in treating patients with advanced esophageal carcinomas. Methods: A total of 32 patients with advanced esophageal carcinoma were randomly divided into irradiation stent group (n=15) and conventional stent group (n=17). Internal irradiation stent loaded with 125 I seeds was employed in patients of irradiation stent group, while conventional self-expandable metal stent was used in patients of conventional stent group. After the treatment, clinical follow-up was regularly conducted. Postoperative complications such as fever, severe chest pain, cough, esophageal perforation, pneumonia, hemorrhage, stent migration and restenosis, etc. were observed. Results: No significant difference in the occurrence of fever, severe chest pain, esophageal perforation and hemorrhage existed between the two groups (P>0.05). The difference in the occurrence of long-term complications such as stent migration or restenosis between the two groups was out statistically significant (P>0.05). However, the restenosis in irradiation stent group occurred obviously much later than that in conventional stent group. Conclusion: For the treatment of advanced esophageal carcinomas, the insertion of internal irradiation esophageal stent is safe. It dose not increase the incidence of postoperative complications. Therefore, it is worth popularizing this technique in clinical practice. (authors)

  3. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    International Nuclear Information System (INIS)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Alstine, William Van; Binkert, Christoph A.; Klausen, Kasper

    2017-01-01

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  4. Bifurcation of elastic solids with sliding interfaces

    Science.gov (United States)

    Bigoni, D.; Bordignon, N.; Piccolroaz, A.; Stupkiewicz, S.

    2018-01-01

    Lubricated sliding contact between soft solids is an interesting topic in biomechanics and for the design of small-scale engineering devices. As a model of this mechanical set-up, two elastic nonlinear solids are considered jointed through a frictionless and bilateral surface, so that continuity of the normal component of the Cauchy traction holds across the surface, but the tangential component is null. Moreover, the displacement can develop only in a way that the bodies in contact do neither detach, nor overlap. Surprisingly, this finite strain problem has not been correctly formulated until now, so this formulation is the objective of the present paper. The incremental equations are shown to be non-trivial and different from previously (and erroneously) employed conditions. In particular, an exclusion condition for bifurcation is derived to show that previous formulations based on frictionless contact or `spring-type' interfacial conditions are not able to predict bifurcations in tension, while experiments-one of which, ad hoc designed, is reported-show that these bifurcations are a reality and become possible when the correct sliding interface model is used. The presented results introduce a methodology for the determination of bifurcations and instabilities occurring during lubricated sliding between soft bodies in contact.

  5. Climate bifurcation during the last deglaciation?

    NARCIS (Netherlands)

    Lenton, T.M.; Livina, V.N.; Dakos, V.; Scheffer, M.

    2012-01-01

    There were two abrupt warming events during the last deglaciation, at the start of the Bolling-Allerod and at the end of the Younger Dryas, but their underlying dynamics are unclear. Some abrupt climate changes may involve gradual forcing past a bifurcation point, in which a prevailing climate state

  6. Bifurcation structure of an optical ring cavity

    DEFF Research Database (Denmark)

    Kubstrup, C.; Mosekilde, Erik

    1996-01-01

    One- and two-dimensional continuation techniques are applied to determine the basic bifurcation structure for an optical ring cavity with a nonlinear absorbing element (the Ikeda Map). By virtue of the periodic structure of the map, families of similar solutions develop in parameter space. Within...

  7. Resource competition: a bifurcation theory approach.

    NARCIS (Netherlands)

    Kooi, B.W.; Dutta, P.S.; Feudel, U.

    2013-01-01

    We develop a framework for analysing the outcome of resource competition based on bifurcation theory. We elaborate our methodology by readdressing the problem of competition of two species for two resources in a chemostat environment. In the case of perfect-essential resources it has been

  8. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  9. Percutaneous coronary intervention for coronary bifurcation disease

    DEFF Research Database (Denmark)

    Lassen, Jens Flensted; Holm, Niels Ramsing; Banning, Adrian

    2016-01-01

    of combining the opinions of interventional cardiologists with the opinions of a large variety of other scientists on bifurcation management. The present 11th EBC consensus document represents the summary of the up-to-date EBC consensus and recommendations. It points to the fact that there is a multitude...

  10. Bifurcation of self-folded polygonal bilayers

    Science.gov (United States)

    Abdullah, Arif M.; Braun, Paul V.; Hsia, K. Jimmy

    2017-09-01

    Motivated by the self-assembly of natural systems, researchers have investigated the stimulus-responsive curving of thin-shell structures, which is also known as self-folding. Self-folding strategies not only offer possibilities to realize complicated shapes but also promise actuation at small length scales. Biaxial mismatch strain driven self-folding bilayers demonstrate bifurcation of equilibrium shapes (from quasi-axisymmetric doubly curved to approximately singly curved) during their stimulus-responsive morphing behavior. Being a structurally instable, bifurcation could be used to tune the self-folding behavior, and hence, a detailed understanding of this phenomenon is appealing from both fundamental and practical perspectives. In this work, we investigated the bifurcation behavior of self-folding bilayer polygons. For the mechanistic understanding, we developed finite element models of planar bilayers (consisting of a stimulus-responsive and a passive layer of material) that transform into 3D curved configurations. Our experiments with cross-linked Polydimethylsiloxane samples that change shapes in organic solvents confirmed our model predictions. Finally, we explored a design scheme to generate gripper-like architectures by avoiding the bifurcation of stimulus-responsive bilayers. Our research contributes to the broad field of self-assembly as the findings could motivate functional devices across multiple disciplines such as robotics, artificial muscles, therapeutic cargos, and reconfigurable biomedical devices.

  11. Modified jailed balloon technique for bifurcation lesions.

    Science.gov (United States)

    Saito, Shigeru; Shishido, Koki; Moriyama, Noriaki; Ochiai, Tomoki; Mizuno, Shingo; Yamanaka, Futoshi; Sugitatsu, Kazuya; Tobita, Kazuki; Matsumi, Junya; Tanaka, Yutaka; Murakami, Masato

    2017-12-04

    We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting. © 2017 Wiley Periodicals, Inc.

  12. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. Stent impact on the geometry of the carotid bifurcation and the course of the internal carotid artery

    International Nuclear Information System (INIS)

    Berkefeld, J.; Zanella, F.E.; Rosendahl, H.; Theron, J.G.; Guimaraens, L.; Treggiari-Venzi, M.M.

    2002-01-01

    A measurement system is proposed to evaluate reconstructive effects of carotid stents on the geometry of the carotid bifurcation and the course of the internal carotid artery. To describe deviations of the stenotic internal carotid artery (ICA) from the extended axis of the common carotid artery (CCA) the CCA-ICA angle is measured between the CCA midaxis and the midaxis of the stenotic ICA segment. Maximal extensions of ICA tortuosities perpendicular to the course of the CCA axis are defined as ICA offset. The measurements were applied to DSA images of 224 carotid stenoses to evaluate variation and correlation between the two parameters. Comparative pre- and post-stent evaluation was performed in two series of 55 and 31 carotid stenoses treated with Wallstents and in a historic control group of 35 stenoses treated with Strecker stents. Straight course of the ICA was associated with low angle and low offset values, whereas tortuous course of the ICA showed larger angle and offset. A moderate linear correlation between the two parameters was found. Corresponding to a straightening of the stented segment, Wallstents reduced mean angle and offset values significantly. In five cases of the second series of Wallstents, transferrals of curves above the distal stent end associated with kinks were observed, and offset remained constant or increased. Strecker stent implantation caused no significant changes of bifurcational geometry. The proposed parameters corresponded to visual aspects of ICA tortuosity and detected reconstructive effects of self-expanding Wallstents on the ICA course. The measurement system may provide a basis for geometric evaluation of different stent types or implantation concepts with the aim: to optimize anatomic recanalization results in tortuous high angle-high offset bifurcations. (orig.)

  14. Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Brianna Miner

    2016-09-01

    Full Text Available History of present illness: A 48-year-old male with unknown past medical history presents as a trauma after being hit by a car traveling approximately 25 miles per hour. On initial presentation, the patient is confused, combative, and not answering questions appropriately. The patient is hypotensive with a blood pressure of 68/40 and a heart rate of 50 beats per minute, with oxygen saturation at 96% on room air. FAST scan is positive for fluid in Morrison’s pouch, splenorenal space, and pericardial space. Significant findings: The initial chest x-ray showed an abnormal superior mediastinal contour (blue line, suggestive of a possible aortic injury. The CT angiogram showed extensive circumferential irregularity and outpouching of the distal aortic arch (red arrows compatible with aortic transection. In addition, there was a circumferential intramural hematoma, which extended through the descending aorta to the proximal infrarenal abdominal aorta (green arrow. There was also an extensive surrounding mediastinal hematoma extending around the descending aorta and supraaortic branches (purple arrows. Discussion: Traumatic aortic injury is a life-threatening event. The incidence of blunt thoracic aortic injury is low, between 1 to 2 percent of those patients with blunt thoracic trauma.1 However, approximately 80% of patients with traumatic aortic injury die at the scene.2 Therefore it is imperative to diagnose traumatic aortic injury in a timely fashion. The diagnosis can be difficult due to the non-specific signs and symptoms and other distracting injuries. Clinical suspicion should be based on the mechanism of the injury and the hemodynamic status of the patient. In any patient with blunt or penetrating trauma to the chest that is hemodynamically unstable, traumatic aortic injury should be on the differential. Chest x-ray can be used as a screening tool. A normal chest x-ray has a negative predictive value of approximately 97%. CTA chest is the

  15. Stochastic bifurcation in a model of love with colored noise

    Science.gov (United States)

    Yue, Xiaokui; Dai, Honghua; Yuan, Jianping

    2015-07-01

    In this paper, we wish to examine the stochastic bifurcation induced by multiplicative Gaussian colored noise in a dynamical model of love where the random factor is used to describe the complexity and unpredictability of psychological systems. First, the dynamics in deterministic love-triangle model are considered briefly including equilibrium points and their stability, chaotic behaviors and chaotic attractors. Then, the influences of Gaussian colored noise with different parameters are explored such as the phase plots, top Lyapunov exponents, stationary probability density function (PDF) and stochastic bifurcation. The stochastic P-bifurcation through a qualitative change of the stationary PDF will be observed and bifurcation diagram on parameter plane of correlation time and noise intensity is presented to find the bifurcation behaviors in detail. Finally, the top Lyapunov exponent is computed to determine the D-bifurcation when the noise intensity achieves to a critical value. By comparison, we find there is no connection between two kinds of stochastic bifurcation.

  16. Bifurcation Behavior Analysis in a Predator-Prey Model

    Directory of Open Access Journals (Sweden)

    Nan Wang

    2016-01-01

    Full Text Available A predator-prey model is studied mathematically and numerically. The aim is to explore how some key factors influence dynamic evolutionary mechanism of steady conversion and bifurcation behavior in predator-prey model. The theoretical works have been pursuing the investigation of the existence and stability of the equilibria, as well as the occurrence of bifurcation behaviors (transcritical bifurcation, saddle-node bifurcation, and Hopf bifurcation, which can deduce a standard parameter controlled relationship and in turn provide a theoretical basis for the numerical simulation. Numerical analysis ensures reliability of the theoretical results and illustrates that three stable equilibria will arise simultaneously in the model. It testifies the existence of Bogdanov-Takens bifurcation, too. It should also be stressed that the dynamic evolutionary mechanism of steady conversion and bifurcation behavior mainly depend on a specific key parameter. In a word, all these results are expected to be of use in the study of the dynamic complexity of ecosystems.

  17. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    Directory of Open Access Journals (Sweden)

    Canena Jorge Manuel

    2012-06-01

    Full Text Available Abstract Background Refractory benign esophageal strictures (RBESs have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs, biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs, for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10, biodegradable stents (n = 10 or FCSEMSs (12 weeks, n = 10. Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60% in the SEPS group, 2 (20% in the biodegradable group and 3 (30% in the FCSEMS group (P = 0.16. A total of 8/30 patients (26.6% were dysphagia-free after the end of follow-up: 1 (10% in the SEPS group, 3 (30% in the biodegradable group and 4 (40% in the FCSEMS group (P = 0.27. More reinterventions were required in the SEPS group (n = 24 than in the biodegradable group (n = 13 or the FCSEMS group (n = 13 (P = 0.24. Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011. Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence.

  18. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  19. Symmetry breaking bifurcations of a current sheet

    International Nuclear Information System (INIS)

    Parker, R.D.; Dewar, R.L.; Johnson, J.L.

    1990-01-01

    Using a time evolution code with periodic boundary conditions, the viscoresistive hydromagnetic equations describing an initially static, planar current sheet with large Lundquist number have been evolved for times long enough to reach a steady state. A cosh 2 x resistivity model was used. For long periodicity lengths L p , the resistivity gradient drives flows that cause forced reconnection at X point current sheets. Using L p as a bifurcation parameter, two new symmetry breaking bifurcations were found: a transition to an asymmetric island chain with nonzero, positive, or negative phase velocity, and a transition to a static state with alternating large and small islands. These states are reached after a complex transient behavior, which involves a competition between secondary current sheet instability and coalescence

  20. Symmetry breaking bifurcations of a current sheet

    International Nuclear Information System (INIS)

    Parker, R.D.; Dewar, R.L.; Johnson, J.L.

    1988-08-01

    Using a time evolution code with periodic boundary conditions, the viscoresistive hydromagnetic equations describing an initially static, planar current sheet with large Lundquist number have been evolved for times long enough to reach a steady state. A cosh 2 x resistivity model was used. For long periodicity lengths, L p , the resistivity gradient drives flows which cause forced reconnection at X point current sheets. Using L p as a bifurcation parameter, two new symmetry breaking bifurcations were found - a transition to an asymmetric island chain with nonzero, positive or negative phase velocity, and a transition to a static state with alternating large and small islands. These states are reached after a complex transient behavior which involves a competition between secondary current sheet instability and coalescence. 31 refs., 6 figs

  1. Experimental Study of Flow in a Bifurcation

    Science.gov (United States)

    Fresconi, Frank; Prasad, Ajay

    2003-11-01

    An instability known as the Dean vortex occurs in curved pipes with a longitudinal pressure gradient. A similar effect is manifest in the flow in a converging or diverging bifurcation, such as those found in the human respiratory airways. The goal of this study is to characterize secondary flows in a bifurcation. Particle image velocimetry (PIV) and laser-induced fluorescence (LIF) experiments were performed in a clear, plastic model. Results show the strength and migration of secondary vortices. Primary velocity features are also presented along with dispersion patterns from dye visualization. Unsteadiness, associated with a hairpin vortex, was also found at higher Re. This work can be used to assess the dispersion of particles in the lung. Medical delivery systems and pollution effect studies would profit from such an understanding.

  2. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.

    Science.gov (United States)

    Jiao, Dechao; Huang, Kai; Zhu, Ming; Wu, Gang; Ren, Jianzhuang; Wang, Yanli; Han, Xinwei

    2017-01-01

    Whether unilateral or bilateral drainage should be performed for malignant hilar biliary obstruction remains a matter of debate. Although a Y-stent with a central wide-open mesh facilitates bilateral stent placement, it has its own limitations. This study aims to evaluate the feasibility and efficacy of a newly designed Y-configured bilateral self-expanding metallic stent (SEMS) for the treatment of hilar biliary obstruction. In this retrospective study, 14 consecutive patients with unresectable malignant hilar biliary obstruction (Bismuth type II or higher), who underwent placement of a newly designed Y-configured bilateral SEMS for hilar biliary obstruction from April 2013 to March 2015, were included into this study. Data on technical success, clinical success, stent patency, complications and patient survival were collected. Technical and clinical success was 100 and 92.9 %, respectively. Mean serum bilirubin level was significantly decreased 1 month after stent placement (P hilar biliary obstruction using port docking deployment.

  3. Bifurcations and chaos of DNA solitonic dynamics

    International Nuclear Information System (INIS)

    Gonzalez, J.A.; Martin-Landrove, M.; Carbo, J.R.; Chacon, M.

    1994-09-01

    We investigated the nonlinear DNA torsional equations proposed by Yakushevich in the presence of damping and external torques. Analytical expressions for some solutions are obtained in the case of the isolated chain. Special attention is paid to the stability of the solutions and the range of soliton interaction in the general case. The bifurcation analysis is performed and prediction of chaos is obtained for some set of parameters. Some biological implications are suggested. (author). 11 refs, 13 figs

  4. Torus bifurcations in multilevel converter systems

    DEFF Research Database (Denmark)

    Zhusubaliyev, Zhanybai T.; Mosekilde, Erik; Yanochkina, Olga O.

    2011-01-01

    embedded one into the other and with their basins of attraction delineated by intervening repelling tori. The paper illustrates the coexistence of three stable tori with different resonance behaviors and shows how reconstruction of these tori takes place across the borders of different dynamical regimes....... The paper also demonstrates how pairs of attracting and repelling tori emerge through border-collision torus-birth and border-collision torus-fold bifurcations. © 2011 World Scientific Publishing Company....

  5. Perturbed period-doubling bifurcation. I. Theory

    DEFF Research Database (Denmark)

    Svensmark, Henrik; Samuelsen, Mogens Rugholm

    1990-01-01

    -defined way that is a function of the amplitude and the frequency of the signal. New scaling laws between the amplitude of the signal and the detuning δ are found; these scaling laws apply to a variety of quantities, e.g., to the shift of the bifurcation point. It is also found that the stability...... of a microwave-driven Josephson junction confirm the theory. Results should be of interest in parametric-amplification studies....

  6. Sex differences in intracranial arterial bifurcations

    DEFF Research Database (Denmark)

    Lindekleiv, Haakon M; Valen-Sendstad, Kristian; Morgan, Michael K

    2010-01-01

    Subarachnoid hemorrhage (SAH) is a serious condition, occurring more frequently in females than in males. SAH is mainly caused by rupture of an intracranial aneurysm, which is formed by localized dilation of the intracranial arterial vessel wall, usually at the apex of the arterial bifurcation. T....... The female preponderance is usually explained by systemic factors (hormonal influences and intrinsic wall weakness); however, the uneven sex distribution of intracranial aneurysms suggests a possible physiologic factor-a local sex difference in the intracranial arteries....

  7. Drift bifurcation detection for dissipative solitons

    International Nuclear Information System (INIS)

    Liehr, A W; Boedeker, H U; Roettger, M C; Frank, T D; Friedrich, R; Purwins, H-G

    2003-01-01

    We report on the experimental detection of a drift bifurcation for dissipative solitons, which we observe in the form of current filaments in a planar semiconductor-gas-discharge system. By introducing a new stochastic data analysis technique we find that due to a change of system parameters the dissipative solitons undergo a transition from purely noise-driven objects with Brownian motion to particles with a dynamically stabilized finite velocity

  8. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  9. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  10. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    International Nuclear Information System (INIS)

    Vajda, Zsolt; Güthe, Thomas; Perez, Marta Aguilar; Kurre, Wiebke; Schmid, Elisabeth; Bäzner, Hansjörg; Henkes, Hans

    2013-01-01

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54–86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  11. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-02-01

    Uncovered self-expandable metal stents (U-SEMSs) and covered self-expandable metal stents (C-SEMSs) are available for palliative therapy for malignant gastric outlet obstruction (GOO). However, clinical differences and indications between the 2 types of SEMSs have not been elucidated. We retrospectively compared 126 patients with U-SEMS and 126 patients with C-SEMSs with regard to clinical outcome and factors predictive of clinical improvement after SEMSs placement. No significant difference was observed between the U-SEMS and C-SEMS groups with respect to technical success, clinical success, GOO score, or time to stent dysfunction. Stent migration was significantly more frequent in patients with C-SEMSs (U-SEMSs, .79%; C-SEMSs, 8.73%; P = .005). Karnofsky performance status, chemotherapy, peritoneal dissemination, and stent expansion ≤ 30% were associated significantly with poor GOO score improvement in multivariable analyses, but stent type was not (P = .213). In subgroup analyses, insufficient (≤30%) stent expansion was an independent factor in patients with U-SEMSs (P = .041) but not C-SEMSs. In the insufficient stent expansion subgroup, C-SEMSs was associated significantly with superior clinical improvement compared with U-SEMSs (P = .01). Insufficient stent expansion was observed more frequently in patients with GI obstruction because of anastomotic sites or metastatic cancer (44.8% [13/29], P = .001). No clinical difference, apart from stent migration, was observed between patients with U-SEMSs and C-SEMSs. GI obstruction because of an anastomotic site or metastatic cancer may be an indication for C-SEMS use to improve oral intake after SEMSs placement. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. The integrated place of tracheobronchial stents in the multidisciplinary management of large post-pneumonectomy fistulas: our experience using a novel customised conical self-expandable metallic stent.

    Science.gov (United States)

    Dutau, Hervé; Breen, David Patrick; Gomez, Carine; Thomas, Pascal Alexandre; Vergnon, Jean-Michel

    2011-02-01

    Stump dehiscence after pneumonectomy is a cause of morbidity and mortality in patients treated for non-small-cell lung carcinoma. Surgical repair remains the treatment of choice but can be postponed or contraindicated. Bronchoscopic techniques may be an option with curative intent or as a bridge towards definitive surgery. The aim of the study is to evaluate the efficacy and the outcome of a new customised covered conical self-expandable metallic stent in the management of large bronchopleural fistulas complicating pneumonectomies. A case series using chart review of non-operable patients presenting with large bronchopleural fistulas (>6mm) post-pneumonectomies as a definitive treatment with curative intent for non-small-cell lung carcinomas and requiring the use of a dedicated conical shaped stent in two tertiary referral centres. Seven patients presenting large post-pneumonectomy fistulas (between 6 and 12 mm) were included. Cessation of the air leak and clinical improvement was achieved in all the patients after stent placement. Stent-related complications (two migrations and one stent rupture) were successfully managed using bronchoscopic techniques in two patients and surgery in one. Mortality, mainly related to overwhelming sepsis, was 57%. Delayed definitive surgery was achieved successfully in three patients (43%). This case series assesses the short-term clinical efficacy of a new customised covered conical self-expandable metallic stent in the multidisciplinary management of large bronchopleural fistulas complicating pneumonectomies in patients deemed non-operable. Long-term benefits are jeopardised by infectious complications. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  13. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  14. PEACE I all-comers registry: patency evaluation after implantation of the 4-French Pulsar-18 self-expanding nitinol stent in femoropopliteal lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Kolks, Oliver; Hailer, Birgit; Stahlhoff, Wilhelm-Friedrich; Tiefenbacher, Christiane; Nolte-Ernsting, Claus; Arjumand, Jawed; Wittenberg, Guenther

    2014-06-01

    To evaluate the 1-year patency of the 4-F Pulsar-18 self-expanding nitinol stent for treatment of femoropopliteal occlusive disease in a national, prospective, multicenter, all-comers registry. Between January and June 2012, the German PEACE I all-comers prospective registry enrolled 148 patients with symptomatic femoropopliteal lesions (Rutherford category 2-5) undergoing recanalization and implantation of the Pulsar-18 SE nitinol stent at 6 clinical centers. Thirty patients did not have the 12-month follow-up visit (18 declined reevaluation, 5 withdrew consent, and 7 died), leaving 118 patients (64 men; mean 71.9±9.6 age years) for the 1-year evaluation. The average lesion length was 111.5±71.4 mm, and 38 of the 118 lesions were classified as TASC II D. More than half the lesions (67, 56.7%) were chronic total occlusions (CTO). The popliteal segment was involved in 22 (18.7%) lesions. The mean stented length was 122.7±64.5 mm. Routine follow-up included duplex ultrasound at 6 and 12 months. Outcome measures were primary patency and no clinically driven target lesion revascularization (TLR) within 12 months. The overall primary patency rates after 6 and 12 months were 87.4% and 79.5%, respectively; in the popliteal segments, the rate was 71.4% after 12 months. The overall freedom from TLR was 93.2% after 6 months and 81% after 12 months. Ankle-brachial index, pain-free walking distance, and Rutherford category all improved significantly (pPulsar-18 self-expanding nitinol stent in femoropopliteal lesions averaging 111.5 mm long showed promising primary patency and freedom from TLR after 6 and 12 months. Diabetes had no negative impact on patency. Primary patency in the popliteal segments was acceptable at 12 months.

  15. Self-expanding metallic stent as a bridge to surgery in the treatment of left colon cancer obstruction: Cost-benefit analysis and oncologic results.

    Science.gov (United States)

    Flor-Lorente, Blas; Báguena, Gloria; Frasson, Matteo; García-Granero, Alvaro; Cervantes, Andrés; Sanchiz, Vicente; Peña, Andres; Espí, Alejandro; Esclapez, Pedro; García-Granero, Eduardo

    2017-03-01

    The use of a self-expanding metallic stent as a bridge to surgery in acute malignant left colonic obstruction has been suggested as an alternative treatment to emergency surgery. The aim of the present study was to compare the morbi-mortality, cost-benefit and long-term oncological outcomes of both therapeutic options. This is a prospective, comparative, controlled, non-randomized study (2005-2010) performed in a specialized unit. The study included 82 patients with left colon cancer obstruction treated by stent as a bridge to surgery (n=27) or emergency surgery (n=55) operated with local curative intention. The main outcome measures (postoperative morbi-mortaliy, cost-benefit, stoma rate and long-term oncological outcomes) were compared based on an "intention-to-treat" analysis. There were no significant statistical differences between the two groups in terms of preoperative data and tumor characteristics. The technically successful stenting rate was 88.9% (11.1% perforation during stent placement) and clinical success was 81.4%. No difference was observed in postoperative morbi-mortality rates. The primary anastomosis rate was higher in the bridge to surgery group compared to the emergency surgery group (77.8% vs. 56.4%; P=.05). The mean costs in the emergency surgery group resulted to be €1,391.9 more expensive per patient than in the bridge to surgery group. There was no significant statistical difference in oncological long-term outcomes. The use of self-expanding metalllic stents as a bridge to surgery is a safe option in the urgent treatment of obstructive left colon cancer, with similar short and long-term results compared to direct surgery, inferior mean costs and a higher rate of primary anastomosis. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p day device safety, success, and efficacy were noted in 79.1%, 89...

  17. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    Science.gov (United States)

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    International Nuclear Information System (INIS)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung

    2013-01-01

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  19. Sequential Hybrid Repair of Aorta and Bilateral Common Iliac Arteries Secondary to Chronic Aortic Dissection with Extensive Aneurysmal Degeneration in a Marfan Patient.

    Science.gov (United States)

    Hinojosa, Carlos A; Anaya-Ayala, Javier E; Laparra-Escareno, Hugo; Lizola, Rene; Torres-Machorro, Adriana

    2017-09-01

    Marfan syndrome is a connective tissue disorder associated with aortic dissection, aneurysmal degeneration and rupture. These cardiovascular complications represent the main cause of mortality, therefore repair is indicated. We present a 35-year-old woman who experienced acute onset of chest pain. Her imaging revealed a chronic DeBakey type I dissection with aortic root dilation and descending thoracic aneurysmal degeneration. She underwent a Bentall procedure and endovascular exclusion of the descending thoracic aortic aneurysm. She was closely followed and 2 years later a computed tomography angiography (CTA) revealed the aneurysmal degeneration of the thoracoabominal aorta and bilateral iliac arteries. The patient underwent a composite reconstruction using multi-visceral branched and bifurcated Dacron grafts. At 5 years from her last surgery, a CTA revealed no new dissection or further aneurysmal degenerations. Aortic disease in Marfan patients is a complex clinical problem that may lead to secondary or tertiary aortic reconstructions; close follow-up is mandatory.

  20. Unusual presentation of aortic dissection: Post-coital acute paraplegia with renal failure

    Directory of Open Access Journals (Sweden)

    Dinith P Galabada

    2014-01-01

    Full Text Available We report the case of a 45-year-old chronic smoker who presented with acute paraplegia occurring during coitus and subsequently developed acute renal failure (ARF requiring dialysis. He had absent peripheral pulses in the lower limbs with evidence of acute ischemia. Doppler study showed dissecting aneurysm of thoracic aorta, thrombotic occlusion of the distal aorta from L1 level up to bifurcation and occlusion of the right renal artery by a thrombus that was confirmed by magnetic resonance imaging of the spine. He was not subjected to any vascular intervention as his lower limbs were not salvageable due to delay in the diagnosis. Post-coital aortic dissection and aortic dissection presenting with acute paraplegia and ARF are very rare. This is probably the first case report with post-coital acute aortic dissection presenting with paraplegia and ARF. This case emphasizes the importance of a careful examination of peripheral pulses in patients presenting with ARF and paraplegia.

  1. Energized Oxygen : Speiser Current Sheet Bifurcation

    Science.gov (United States)

    George, D. E.; Jahn, J. M.

    2017-12-01

    A single population of energized Oxygen (O+) is shown to produce a cross-tail bifurcated current sheet in 2.5D PIC simulations of the magnetotail without the influence of magnetic reconnection. Treatment of oxygen in simulations of space plasmas, specifically a magnetotail current sheet, has been limited to thermal energies despite observations of and mechanisms which explain energized ions. We performed simulations of a homogeneous oxygen background, that has been energized in a physically appropriate manner, to study the behavior of current sheets and magnetic reconnection, specifically their bifurcation. This work uses a 2.5D explicit Particle-In-a-Cell (PIC) code to investigate the dynamics of energized heavy ions as they stream Dawn-to-Dusk in the magnetotail current sheet. We present a simulation study dealing with the response of a current sheet system to energized oxygen ions. We establish a, well known and studied, 2-species GEM Challenge Harris current sheet as a starting point. This system is known to eventually evolve and produce magnetic reconnection upon thinning of the current sheet. We added a uniform distribution of thermal O+ to the background. This 3-species system is also known to eventually evolve and produce magnetic reconnection. We add one additional variable to the system by providing an initial duskward velocity to energize the O+. We also traced individual particle motion within the PIC simulation. Three main results are shown. First, energized dawn- dusk streaming ions are clearly seen to exhibit sustained Speiser motion. Second, a single population of heavy ions clearly produces a stable bifurcated current sheet. Third, magnetic reconnection is not required to produce the bifurcated current sheet. Finally a bifurcated current sheet is compatible with the Harris current sheet model. This work is the first step in a series of investigations aimed at studying the effects of energized heavy ions on magnetic reconnection. This work differs

  2. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  3. Transcatheter aortic valve implantation in patients with a mitral prosthesis; single center experience and review of literature.

    Science.gov (United States)

    Asil, Serkan; Şahiner, Levent; Özer, Necla; Kaya, E Barış; Evranos, Banu; Canpolat, Uğur; Yorgun, Hikmet; Karagöz, Heves; Aytemir, Kudret

    2016-10-15

    Following the encouraging results of several registries and trials, transcatheter aortic valve implantation (TAVI) has been recognized as a valid option in patients with severe aortic stenosis deemed at high or prohibitive risk for surgical treatment. Good procedural success and good clinical outcomes have been showed and very limited data exist on TAVI in the setting of a preexisting mitral prosthesis regarding the technique, potential complications, and outcomes. Here, we report six cases of transfemoral TAVI with a self-expanding bioprosthesis (CoreValve; Medtronic, Inc) in patients who had previously undergone mitral valve replacement. Preprocedural, intraprocedural ve postprocedural outcome and data were analyzed and a brief literature review is also presented. Our experiences show that transfemoral CoreValve implantation can be performed successfully in patients with mechanical and bioprosthetic mitral valves. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Robotic aortic surgery.

    Science.gov (United States)

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  5. Global Bifurcation of a Novel Computer Virus Propagation Model

    Directory of Open Access Journals (Sweden)

    Jianguo Ren

    2014-01-01

    Full Text Available In a recent paper by J. Ren et al. (2012, a novel computer virus propagation model under the effect of the antivirus ability in a real network is established. The analysis there only partially uncovers the dynamics behaviors of virus spread over the network in the case where around bifurcation is local. In the present paper, by mathematical analysis, it is further shown that, under appropriate parameter values, the model may undergo a global B-T bifurcation, and the curves of saddle-node bifurcation, Hopf bifurcation, and homoclinic bifurcation are obtained to illustrate the qualitative behaviors of virus propagation. On this basis, a collection of policies is recommended to prohibit the virus prevalence. To our knowledge, this is the first time the global bifurcation has been explored for the computer virus propagation. Theoretical results and corresponding suggestions may help us suppress or eliminate virus propagation in the network.

  6. Bifurcation theory for finitely smooth planar autonomous differential systems

    Science.gov (United States)

    Han, Maoan; Sheng, Lijuan; Zhang, Xiang

    2018-03-01

    In this paper we establish bifurcation theory of limit cycles for planar Ck smooth autonomous differential systems, with k ∈ N. The key point is to study the smoothness of bifurcation functions which are basic and important tool on the study of Hopf bifurcation at a fine focus or a center, and of Poincaré bifurcation in a period annulus. We especially study the smoothness of the first order Melnikov function in degenerate Hopf bifurcation at an elementary center. As we know, the smoothness problem was solved for analytic and C∞ differential systems, but it was not tackled for finitely smooth differential systems. Here, we present their optimal regularity of these bifurcation functions and their asymptotic expressions in the finite smooth case.

  7. Bifurcation structure of a model of bursting pancreatic cells

    DEFF Research Database (Denmark)

    Mosekilde, Erik; Lading, B.; Yanchuk, S.

    2001-01-01

    . The transition from this structure to the so-called period-adding structure is found to involve a subcritical period-doubling bifurcation and the emergence of type-III intermittency. The period-adding transition itself is not smooth but consists of a saddle-node bifurcation in which (n + 1)-spike bursting...... behavior is born, slightly overlapping with a subcritical period-doubling bifurcation in which n-spike bursting behavior loses its stability.......One- and two-dimensional bifurcation studies of a prototypic model of bursting oscillations in pancreatic P-cells reveal a squid-formed area of chaotic dynamics in the parameter plane, with period-doubling bifurcations on one side of the arms and saddle-node bifurcations on the other...

  8. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  9. Nonlinear physical systems spectral analysis, stability and bifurcations

    CERN Document Server

    Kirillov, Oleg N

    2013-01-01

    Bringing together 18 chapters written by leading experts in dynamical systems, operator theory, partial differential equations, and solid and fluid mechanics, this book presents state-of-the-art approaches to a wide spectrum of new and challenging stability problems.Nonlinear Physical Systems: Spectral Analysis, Stability and Bifurcations focuses on problems of spectral analysis, stability and bifurcations arising in the nonlinear partial differential equations of modern physics. Bifurcations and stability of solitary waves, geometrical optics stability analysis in hydro- and magnetohydrodynam

  10. Stability and bifurcation analysis in a delayed SIR model

    International Nuclear Information System (INIS)

    Jiang Zhichao; Wei Junjie

    2008-01-01

    In this paper, a time-delayed SIR model with a nonlinear incidence rate is considered. The existence of Hopf bifurcations at the endemic equilibrium is established by analyzing the distribution of the characteristic values. A explicit algorithm for determining the direction of the Hopf bifurcation and the stability of the bifurcating periodic solutions are derived by using the normal form and the center manifold theory. Numerical simulations to support the analytical conclusions are carried out

  11. Bifurcation of rupture path by linear and cubic damping force

    Science.gov (United States)

    Dennis L. C., C.; Chew X., Y.; Lee Y., C.

    2014-06-01

    Bifurcation of rupture path is studied for the effect of linear and cubic damping. Momentum equation with Rayleigh factor was transformed into ordinary differential form. Bernoulli differential equation was obtained and solved by the separation of variables. Analytical or exact solutions yielded the bifurcation was visible at imaginary part when the wave was non dispersive. For the dispersive wave, bifurcation of rupture path was invisible.

  12. A codimension two bifurcation in a railway bogie system

    DEFF Research Database (Denmark)

    Zhang, Tingting; True, Hans; Dai, Huanyun

    2017-01-01

    In this paper, a comprehensive analysis is presented to investigate a codimension two bifurcation that exists in a nonlinear railway bogie dynamic system combining theoretical analysis with numerical investigation. By using the running velocity V and the primary longitudinal stiffness (Formula...... coexist in a range of the bifurcation parameters which can lead to jumps in the lateral oscillation amplitude of the railway bogie system. Furthermore, reduce the values of the bifurcation parameters gradually. Firstly, the supercritical Hopf bifurcation turns into a subcritical one with multiple limit...

  13. Hopf bifurcation for tumor-immune competition systems with delay

    Directory of Open Access Journals (Sweden)

    Ping Bi

    2014-01-01

    Full Text Available In this article, a immune response system with delay is considered, which consists of two-dimensional nonlinear differential equations. The main purpose of this paper is to explore the Hopf bifurcation of a immune response system with delay. The general formula of the direction, the estimation formula of period and stability of bifurcated periodic solution are also given. Especially, the conditions of the global existence of periodic solutions bifurcating from Hopf bifurcations are given. Numerical simulations are carried out to illustrate the the theoretical analysis and the obtained results.

  14. Predicting bifurcation angle effect on blood flow in the microvasculature.

    Science.gov (United States)

    Yang, Jiho; Pak, Y Eugene; Lee, Tae-Rin

    2016-11-01

    Since blood viscosity is a basic parameter for understanding hemodynamics in human physiology, great amount of research has been done in order to accurately predict this highly non-Newtonian flow property. However, previous works lacked in consideration of hemodynamic changes induced by heterogeneous vessel networks. In this paper, the effect of bifurcation on hemodynamics in a microvasculature is quantitatively predicted. The flow resistance in a single bifurcation microvessel was calculated by combining a new simple mathematical model with 3-dimensional flow simulation for varying bifurcation angles under physiological flow conditions. Interestingly, the results indicate that flow resistance induced by vessel bifurcation holds a constant value of approximately 0.44 over the whole single bifurcation model below diameter of 60μm regardless of geometric parameters including bifurcation angle. Flow solutions computed from this new model showed substantial decrement in flow velocity relative to other mathematical models, which do not include vessel bifurcation effects, while pressure remained the same. Furthermore, when applying the bifurcation angle effect to the entire microvascular network, the simulation results gave better agreements with recent in vivo experimental measurements. This finding suggests a new paradigm in microvascular blood flow properties, that vessel bifurcation itself, regardless of its angle, holds considerable influence on blood viscosity, and this phenomenon will help to develop new predictive tools in microvascular research. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Double Hopf bifurcation in delay differential equations

    Directory of Open Access Journals (Sweden)

    Redouane Qesmi

    2014-07-01

    Full Text Available The paper addresses the computation of elements of double Hopf bifurcation for retarded functional differential equations (FDEs with parameters. We present an efficient method for computing, simultaneously, the coefficients of center manifolds and normal forms, in terms of the original FDEs, associated with the double Hopf singularity up to an arbitrary order. Finally, we apply our results to a nonlinear model with periodic delay. This shows the applicability of the methodology in the study of delay models arising in either natural or technological problems.

  16. Bifurcation theory for toroidal MHD instabilities

    International Nuclear Information System (INIS)

    Maschke, E.K.; Morros Tosas, J.; Urquijo, G.

    1992-01-01

    Using a general representation of magneto-hydrodynamics in terms of stream functions and potentials, proposed earlier, a set of reduced MHD equations for the case of toroidal geometry had been derived by an appropriate ordering with respect to the inverse aspect ratio. When all dissipative terms are neglected in this reduced system, it has the same linear stability limits as the full ideal MHD equations, to the order considered. When including resistivity, thermal conductivity and viscosity, we can apply bifurcation theory to investigate nonlinear stationary solution branches related to various instabilities. In particular, we show that a stationary solution of the internal kink type can be found

  17. Bifurcation of Mobility, Bifurcation of Law : Externalization of migration policy before the EU Court of Justice

    NARCIS (Netherlands)

    Spijkerboer, T.P.

    2017-01-01

    The externalization of European migration policy has resulted in a bifurcation of global human mobility, which is divided along a North/South axis. In two judgments, the EU Court of Justice was confronted with cases challenging the exclusion of Syrian refugees from Europe. These cases concern core

  18. Double aortic arch

    Science.gov (United States)

    Surgery can be done to fix double aortic arch. The surgeon ties off the smaller branch and separates it from the larger branch. Then the surgeon closes the ends of the aorta with stitches. This relieves pressure on the esophagus and windpipe.

  19. Bicuspid aortic valve

    Science.gov (United States)

    ... aortic disease. In: Otto CM, Bonow RO, eds. Valvular Heart Disease: A Companion to Braunwald’s Heart Disease . 4th ed. ... PA: Elsevier Saunders; 2014:chap 13. Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman’s Cecil ...

  20. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  1. Familial Thoracic Aortic Aneurysm with Dissection Presenting as Flash Pulmonary Edema in a 26-Year-Old Man

    Directory of Open Access Journals (Sweden)

    Sabry Omar

    2014-01-01

    Full Text Available We are reporting a case of familial thoracic aortic aneurysm and dissection in a 26-year-old man with no significant past medical history and a family history of dissecting aortic aneurysm in his mother at the age of 40. The patient presented with cough, shortness of breath, and chest pain. Chest X-ray showed bilateral pulmonary infiltrates. CT scan of the chest showed a dissection of the ascending aorta. The patient underwent aortic dissection repair and three months later he returned to our hospital with new complaints of back pain. CT angiography showed a new aortic dissection extending from the left carotid artery through the bifurcation and into the iliac arteries. The patient underwent replacement of the aortic root, ascending aorta, total aortic arch, and aortic valve. The patient recovered well postoperatively. Genetic studies of the patient and his children revealed no mutations in ACTA2, TGFBR1, TGFBR2, TGFB2, MYH11, MYLK, SMAD3, or FBN1. This case report focuses on a patient with familial TAAD and discusses the associated genetic loci and available screening methods. It is important to recognize potential cases of familial TAAD and understand the available screening methods since early diagnosis allows appropriate management of risk factors and treatment when necessary.

  2. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    Science.gov (United States)

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  3. Placement of a covered self-expandable nitinol stent for bile duct stricture that caused by ischemic injury after transcatheter arterial chemoembolization in a patient with hepatocellular carcinoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kweon; Seo, Tae Seok; Cha, In Ho; Huh, Sik; Byun, Kwan Soo [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2008-10-15

    The authors report here on a case of focal stricture in the common hepatic duct that was caused by ischemic bile duct injury after repeat TACE procedures for hepatocellular carcinoma, and the patient was successfully treated with a covered self-expandable nitinol stent.

  4. Bifurcation into functional niches in adaptation.

    Science.gov (United States)

    White, Justin S; Adami, Christoph

    2004-01-01

    One of the central questions in evolutionary biology concerns the dynamics of adaptation and diversification. This issue can be addressed experimentally if replicate populations adapting to identical environments can be investigated in detail. We have studied 501 such replicas using digital organisms adapting to at least two fundamentally different functional niches (survival strategies) present in the same environment: one in which fast replication is the way to live, and another where exploitation of the environment's complexity leads to complex organisms with longer life spans and smaller replication rates. While these two modes of survival are closely analogous to those expected to emerge in so-called r and K selection scenarios respectively, the bifurcation of evolutionary histories according to these functional niches occurs in identical environments, under identical selective pressures. We find that the branching occurs early, and leads to drastic phenotypic differences (in fitness, sequence length, and gestation time) that are permanent and irreversible. This study confirms an earlier experimental effort using microorganisms, in that diversification can be understood at least in part in terms of bifurcations on saddle points leading to peak shifts, as in the picture drawn by Sewall Wright.

  5. Bifurcation theory of ac electric arcing

    International Nuclear Information System (INIS)

    Christen, Thomas; Peinke, Emanuel

    2012-01-01

    The performance of alternating current (ac) electric arcing devices is related to arc extinction or its re-ignition at zero crossings of the current (so-called ‘current zero’, CZ). Theoretical investigations thus usually focus on the transient behaviour of arcs near CZ, e.g. by solving the modelling differential equations in the vicinity of CZ. This paper proposes as an alternative approach to investigate global mathematical properties of the underlying periodically driven dynamic system describing the electric circuit containing the arcing device. For instance, the uniqueness of the trivial solution associated with the insulating state indicates the extinction of any arc. The existence of non-trivial attractors (typically a time-periodic state) points to a re-ignition of certain arcs. The performance regions of arcing devices, such as circuit breakers and arc torches, can thus be identified with the regions of absence and existence, respectively, of non-trivial attractors. Most important for applications, the boundary of a performance region in the model parameter space is then associated with the bifurcation of the non-trivial attractors. The concept is illustrated for simple black-box arc models, such as the Mayr and the Cassie model, by calculating for various cases the performance boundaries associated with the bifurcation of ac arcs. (paper)

  6. Treatment of Benign and Malignant Tracheobronchial Obstruction with Metal Wire Stents: Experience with a Balloon-Expandable and a Self-Expandable Stent Type

    International Nuclear Information System (INIS)

    Rieger, Johannes; Hautmann, Hubert; Linsenmaier, Ulrich; Weber, Cristoph; Treitl, Markus; Huber, R.M.; Pfeifer, Klaus-Juergen

    2004-01-01

    Over the last few years various types of metal wire stents have been increasingly employed in the treatment of both malignant and benign tracheobronchial obstruction. To date, however, few studies have investigated the in vivo properties of different stent types. We implanted 26 balloon-expandable tantalum Strecker stents (18 patients) and 18 self-expandable Wallstents (16 patients) into the tracheobronchial system of 30 patients with combined stenting in 4 patients. Mean age was 51 years (range: 0.5-79 years). Malignant disease was present in 23 patients, benign disease in seven patients. Both patients and individual stents were monitored clinically and radiographically. The probability of stents remaining within the tracheobronchial system, and of their remaining undislocated and uncompressed was calculated using Kaplan-Meier analysis for both stent types. Average stent follow-up time was 112 days until explantation and 115 days until patients' death or discharge. Kaplan-Meier analysis revealed a higher probability for the Wallstent to remain within the tracheobronchial system. Dislocation and compression occurred more rarely. Explantation, however, if desired, was more difficult compared to the Strecker stent. The Wallstent also led to the formation of granulation tissue, especially at the proximal stent end, frequently requiring reintervention. Both stent types proved to be effective therapeutic options in the management of obstructive tracheobronchial disease. The mechanical properties of the Strecker stent seem to be less favorable compared to the Wallstent but removal is easy. For benign disease, however, the Wallstent reveals limitations due to significant side effects

  7. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  8. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    International Nuclear Information System (INIS)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong

    2017-01-01

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT

  9. Assessment of safety and efficacy of an indigenous self-expandable fully covered esophageal metal stent for palliation of esophageal cancer.

    Science.gov (United States)

    Padhan, R K; Nongthombam, S K; Venuthurimilli, A; Dhingra, R; Sahni, P; Garg, P K

    2016-01-01

    Patients with unresectable esophageal cancer require palliation for dysphagia. Placement of a self-expandable metal stent (SEMS) is the procedure of choice for palliation of dysphagia. To evaluate the safety and efficacy of an indigenous fully-covered SEMS in patients with esophageal cancer. Eligible patients with unresectable esophageal cancer requiring palliation for dysphagia were included in the study. An indigenous fully covered SEMS of appropriate length was placed under endoscopic and fluoroscopic guidance. Outcome measures assessed were adverse events and improvement in dysphagia. Twenty one patients (mean age 57.71±13.14 years; 17 males) were included. After stenting, dysphagia score decreased from 3.2+0.4 to 0.35+0.74 at 4 weeks. Adverse events included retrosternal pain, respiratory distress and aspiration pneumonia in 12, 2 and 1 patients respectively. Five patients required repeat stenting due to stent migration in 4 (following radiotherapy in 3) and tumour ingrowth in 1. There was primary stent malfunction in one patient. The median survival of patients was 140 (76-199) days, which was higher in those who received radiotherapy. The stent was reasonably safe and effective to relieve dysphagia due to unresectable esophageal cancer.

  10. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  11. Fluoroscopic removal of retrievable self-expandable metal stents in patients with malignant oesophageal strictures: Experience with a non-endoscopic removal system.

    Science.gov (United States)

    Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae

    2017-03-01

    To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (Pstent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.

  12. Efficacy of Endoscopic Over 3-branched Partial Stent-in-Stent Drainage Using Self-expandable Metallic Stents in Patients With Unresectable Hilar Biliary Carcinoma.

    Science.gov (United States)

    Uchida, Daisuke; Kato, Hironari; Muro, Shinichiro; Noma, Yasuhiro; Yamamoto, Naoki; Horiguchi, Shigeru; Harada, Ryo; Tsutsumi, Koichiro; Kawamoto, Hirofumi; Okada, Hiroyuki; Yamamoto, Kazuhide

    2015-07-01

    The treatment of biliary stricture is crucially important for continuing stable chemotherapy for unresectable biliary carcinoma; however, there is no consensus regarding the use of hilar biliary drainage. In this study, we examined the efficacy of endoscopic over 3-branched biliary drainage using self-expandable metallic stents (SEMSs) in patients with unresectable malignant hilar biliary stricture (HBS). A total of 77 patients with unresectable HBS treated with a SEMS and chemotherapy were retrospectively reviewed. There were 59 patients with cholangiocarcinoma and 18 patients with gallbladder carcinoma. The patients were divided into 2 groups (4- or 3-branched group and 2- or 1-branched group) and compared with respect to the duration of stent patency and overall survival. A comparison of the patients' baseline characteristics showed no significant differences between the 4- or 3-branched group and the 2- or 1-branched group. Neither the duration of patency nor survival time exhibited significant differences between the 2 groups, although, among the patients achieving disease control , the duration of patency period and survival time of the 4- or 3-branched group were significantly higher than those observed in the 2- or 1-branched group (P=0.0231 and 0.0466). The use of endoscopic over 3-branched biliary drainage with a SEMS may improve the duration of patency in patients with HBS.

  13. Outcomes of the Use of Fully Covered Esophageal Self-Expandable Stent in the Management of Colorectal Anastomotic Strictures and Leaks

    Directory of Open Access Journals (Sweden)

    Chad J. Cooper

    2014-01-01

    Full Text Available Introduction. Colorectal anastomotic leak or stricture is a dreaded complication leading to significant morbidity and mortality. The novel use of self-expandable metal stents (SEMS in the management of postoperative colorectal anastomotic leaks or strictures can avoid surgical reintervention. Methods. Retrospective study with particular attention to the indications, operative or postoperative complications, and clinical outcomes of SEMS placement for patients with either a colorectal anastomotic stricture or leak. Results. Eight patients had SEMS (WallFlex stent for the management of postoperative colorectal anastomotic leak or stricture. Five had a colorectal anastomotic stricture and 3 had a colorectal anastomotic leak. Complete resolution of the anastomotic stricture or leak was achieved in all patients. Three had recurrence of the anastomotic stricture on 3-month flexible sigmoidoscopy follow-up after the initial stent was removed. Two of these patients had a stricture that was technically too difficult to place another stent. Stent migration was noted in 2 patients, one at day 3 and the other at day 14 after stent placement that required a larger 23 mm stent to be placed. Conclusions. The use of SEMS in the management of colorectal anastomotic leaks or strictures is feasible and is associated with high technical and clinical success rate.

  14. Management of acute cholangitis as a result of occlusion from a self-expandable metallic stent in patients with malignant distal and hilar biliary obstructions.

    Science.gov (United States)

    Shiomi, Hideyuki; Matsumoto, Kazuya; Isayama, Hiroyuki

    2017-04-01

    Acute cholangitis as a result of common bile duct stones can be managed; however, cholangitis caused by occlusion with a biliary self-expandable metallic stent (SEMS) in patients with an unresectable malignant biliary obstruction has not been fully discussed. The acute cholangitis clinical guidelines (Tokyo Guidelines 2013) recommend following the same procedure as that used for cholangitis; however, the patient's condition, including performance status, tumor extension or staging, and prognosis must be considered. Most physicians manage cholangitis from a SEMS occlusion using a two-step procedure. They insert endoscopic drainage with a plastic stent or insert a nasobiliary drainage tube, which does not exacerbate sepsis. Addition or replacement of a biliary SEMS is required in many cases depending on the cause of the occlusion. Tumor ingrowth through the stent mesh is common in uncovered SEMS and requires placement of another stent in an in-stent method. However, covered SEMS tends to be occluded by sludge, so it must be replaced because of the bacterial biofilm that forms on the covering membrane. The location of the biliary stricture (hilar or distal) should also be considered. Strategies for managing cholangitis as a result of occlusion by a biliary SEMS remain controversial, so prospective clinical trials are needed. © 2017 The Authors. Digestive Endoscopy © 2017 Japan Gastroenterological Endoscopy Society.

  15. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  16. The New Nitinol Conformable Self-Expandable Metal Stents for Malignant Colonic Obstruction: A Pilot Experience as Bridge to Surgery Treatment

    Directory of Open Access Journals (Sweden)

    Roberto Di Mitri

    2014-01-01

    Full Text Available Introduction. Self-expandable metal stents (SEMS are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%, with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50% were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21. Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction.

  17. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  18. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Analysis of Vehicle Steering and Driving Bifurcation Characteristics

    Directory of Open Access Journals (Sweden)

    Xianbin Wang

    2015-01-01

    Full Text Available The typical method of vehicle steering bifurcation analysis is based on the nonlinear autonomous vehicle model deriving from the classic two degrees of freedom (2DOF linear vehicle model. This method usually neglects the driving effect on steering bifurcation characteristics. However, in the steering and driving combined conditions, the tyre under different driving conditions can provide different lateral force. The steering bifurcation mechanism without the driving effect is not able to fully reveal the vehicle steering and driving bifurcation characteristics. Aiming at the aforementioned problem, this paper analyzed the vehicle steering and driving bifurcation characteristics with the consideration of driving effect. Based on the 5DOF vehicle system dynamics model with the consideration of driving effect, the 7DOF autonomous system model was established. The vehicle steering and driving bifurcation dynamic characteristics were analyzed with different driving mode and driving torque. Taking the front-wheel-drive system as an example, the dynamic evolution process of steering and driving bifurcation was analyzed by phase space, system state variables, power spectral density, and Lyapunov index. The numerical recognition results of chaos were also provided. The research results show that the driving mode and driving torque have the obvious effect on steering and driving bifurcation characteristics.

  20. Sediment discharge division at two tidally influenced river bifurcations

    NARCIS (Netherlands)

    Sassi, M.G.; Hoitink, A.J.F.; Vermeulen, B.; Hidayat, H.

    2013-01-01

    [1] We characterize and quantify the sediment discharge division at two tidally influenced river bifurcations in response to mean flow and secondary circulation by employing a boat-mounted acoustic Doppler current profiler (ADCP), to survey transects at bifurcating branches during a semidiurnal

  1. Views on the Hopf bifurcation with respect to voltage instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Roa-Sepulveda, C A [Universidad de Concepcion, Concepcion (Chile). Dept. de Ingenieria Electrica; Knight, U G [Imperial Coll. of Science and Technology, London (United Kingdom). Dept. of Electrical and Electronic Engineering

    1994-12-31

    This paper presents a sensitivity study of the Hopf bifurcation phenomenon which can in theory appear in power systems, with reference to the dynamics of the process and the impact of demand characteristics. Conclusions are drawn regarding power levels at which these bifurcations could appear and concern the concept of the imaginary axis as a `hard` limit eigenvalue analyses. (author) 20 refs., 31 figs.

  2. Bifurcations of heterodimensional cycles with two saddle points

    Energy Technology Data Exchange (ETDEWEB)

    Geng Fengjie [School of Information Technology, China University of Geosciences (Beijing), Beijing 100083 (China)], E-mail: gengfengjie_hbu@163.com; Zhu Deming [Department of Mathematics, East China Normal University, Shanghai 200062 (China)], E-mail: dmzhu@math.ecnu.edu.cn; Xu Yancong [Department of Mathematics, East China Normal University, Shanghai 200062 (China)], E-mail: yancongx@163.com

    2009-03-15

    The bifurcations of 2-point heterodimensional cycles are investigated in this paper. Under some generic conditions, we establish the existence of one homoclinic loop, one periodic orbit, two periodic orbits, one 2-fold periodic orbit, and the coexistence of one periodic orbit and heteroclinic loop. Some bifurcation patterns different to the case of non-heterodimensional heteroclinic cycles are revealed.

  3. Numerical bifurcation analysis of a class of nonlinear renewal equations

    NARCIS (Netherlands)

    Breda, Dimitri; Diekmann, Odo; Liessi, Davide; Scarabel, Francesca

    2016-01-01

    We show, by way of an example, that numerical bifurcation tools for ODE yield reliable bifurcation diagrams when applied to the pseudospectral approximation of a one-parameter family of nonlinear renewal equations. The example resembles logistic-and Ricker-type population equations and exhibits

  4. Travelling waves and their bifurcations in the Lorenz-96 model

    Science.gov (United States)

    van Kekem, Dirk L.; Sterk, Alef E.

    2018-03-01

    In this paper we study the dynamics of the monoscale Lorenz-96 model using both analytical and numerical means. The bifurcations for positive forcing parameter F are investigated. The main analytical result is the existence of Hopf or Hopf-Hopf bifurcations in any dimension n ≥ 4. Exploiting the circulant structure of the Jacobian matrix enables us to reduce the first Lyapunov coefficient to an explicit formula from which it can be determined when the Hopf bifurcation is sub- or supercritical. The first Hopf bifurcation for F > 0 is always supercritical and the periodic orbit born at this bifurcation has the physical interpretation of a travelling wave. Furthermore, by unfolding the codimension two Hopf-Hopf bifurcation it is shown to act as an organising centre, explaining dynamics such as quasi-periodic attractors and multistability, which are observed in the original Lorenz-96 model. Finally, the region of parameter values beyond the first Hopf bifurcation value is investigated numerically and routes to chaos are described using bifurcation diagrams and Lyapunov exponents. The observed routes to chaos are various but without clear pattern as n → ∞.

  5. Bifurcations of heterodimensional cycles with two saddle points

    International Nuclear Information System (INIS)

    Geng Fengjie; Zhu Deming; Xu Yancong

    2009-01-01

    The bifurcations of 2-point heterodimensional cycles are investigated in this paper. Under some generic conditions, we establish the existence of one homoclinic loop, one periodic orbit, two periodic orbits, one 2-fold periodic orbit, and the coexistence of one periodic orbit and heteroclinic loop. Some bifurcation patterns different to the case of non-heterodimensional heteroclinic cycles are revealed.

  6. Bifurcation diagram of a cubic three-parameter autonomous system

    Directory of Open Access Journals (Sweden)

    Lenka Barakova

    2005-07-01

    Full Text Available In this paper, we study the cubic three-parameter autonomous planar system $$displaylines{ dot x_1 = k_1 + k_2x_1 - x_1^3 - x_2,cr dot x_2 = k_3 x_1 - x_2, }$$ where $k_2, k_3$ are greater than 0. Our goal is to obtain a bifurcation diagram; i.e., to divide the parameter space into regions within which the system has topologically equivalent phase portraits and to describe how these portraits are transformed at the bifurcation boundaries. Results may be applied to the macroeconomical model IS-LM with Kaldor's assumptions. In this model existence of a stable limit cycles has already been studied (Andronov-Hopf bifurcation. We present the whole bifurcation diagram and among others, we prove existence of more difficult bifurcations and existence of unstable cycles.

  7. Critical bifurcation surfaces of 3D discrete dynamics

    Directory of Open Access Journals (Sweden)

    Michael Sonis

    2000-01-01

    Full Text Available This paper deals with the analytical representation of bifurcations of each 3D discrete dynamics depending on the set of bifurcation parameters. The procedure of bifurcation analysis proposed in this paper represents the 3D elaboration and specification of the general algorithm of the n-dimensional linear bifurcation analysis proposed by the author earlier. It is proven that 3D domain of asymptotic stability (attraction of the fixed point for a given 3D discrete dynamics is bounded by three critical bifurcation surfaces: the divergence, flip and flutter surfaces. The analytical construction of these surfaces is achieved with the help of classical Routh–Hurvitz conditions of asymptotic stability. As an application the adjustment process proposed by T. Puu for the Cournot oligopoly model is considered in detail.

  8. Bifurcation of transition paths induced by coupled bistable systems.

    Science.gov (United States)

    Tian, Chengzhe; Mitarai, Namiko

    2016-06-07

    We discuss the transition paths in a coupled bistable system consisting of interacting multiple identical bistable motifs. We propose a simple model of coupled bistable gene circuits as an example and show that its transition paths are bifurcating. We then derive a criterion to predict the bifurcation of transition paths in a generalized coupled bistable system. We confirm the validity of the theory for the example system by numerical simulation. We also demonstrate in the example system that, if the steady states of individual gene circuits are not changed by the coupling, the bifurcation pattern is not dependent on the number of gene circuits. We further show that the transition rate exponentially decreases with the number of gene circuits when the transition path does not bifurcate, while a bifurcation facilitates the transition by lowering the quasi-potential energy barrier.

  9. Hopf Bifurcation of Compound Stochastic van der Pol System

    Directory of Open Access Journals (Sweden)

    Shaojuan Ma

    2016-01-01

    Full Text Available Hopf bifurcation analysis for compound stochastic van der Pol system with a bound random parameter and Gaussian white noise is investigated in this paper. By the Karhunen-Loeve (K-L expansion and the orthogonal polynomial approximation, the equivalent deterministic van der Pol system can be deduced. Based on the bifurcation theory of nonlinear deterministic system, the critical value of bifurcation parameter is obtained and the influence of random strength δ and noise intensity σ on stochastic Hopf bifurcation in compound stochastic system is discussed. At last we found that increased δ can relocate the critical value of bifurcation parameter forward while increased σ makes it backward and the influence of δ is more sensitive than σ. The results are verified by numerical simulations.

  10. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. Quantification of progression and regression of descending thoracic aortic wall thickness by enhanced computed tomography

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi; Takasu, Junichiro; Yamamoto, Rie; Taguchi, Rie; Itani, Yasutaka; Ito, Yuichi; Watanabe, Shigeru; Masuda, Yoshiaki

    2001-01-01

    The purpose of this study is to verify the usefulness of the quantification of aortic wall involvement by enhanced computed tomography (CT). One-hundred thirteen Japanese patients underwent two enhanced CT of the descending thoracic aorta at intervals. We sliced the descending thoracic aorta continuously from the level of the tracheal bifurcation with 1 cm intervals, and we defined aortic wall volume (AWV) (cm 3 ) as the sum of a 7-slice area of aortic wall involving calcification. The average of AWV increased from 7.95±2.92 cm 3 to 8.70±2.98 cm 3 . The developmental rate of AWV (ΔAWV) was 0.270±0.281 cm 3 /year. ΔAWV did not have a significant correlation with any risk factor at the baseline. ΔAWV had significant correlation with total cholesterol, (LDL-C) low-density lipoprotein cholesterol and LDL-C/(HDL-C) high-density lipoprotein cholesterol ratio at the follow-up, and by multivariate analysis with only the LDL-C/HDL-C ratio. ΔAWV was not correlated with the intake status of hypoglycemic, antihypertensive or lipid-lowering drugs. The cut-off level of total cholesterol with the most significant odds ratio for progression of aortic wall was 190 mg/dl, and that of LDL-C was 130 mg/dl. This method proved to be useful for the non-invasive assessment of aortic wall thickness. (author)

  12. Bifurcation of solutions to Hamiltonian boundary value problems

    Science.gov (United States)

    McLachlan, R. I.; Offen, C.

    2018-06-01

    A bifurcation is a qualitative change in a family of solutions to an equation produced by varying parameters. In contrast to the local bifurcations of dynamical systems that are often related to a change in the number or stability of equilibria, bifurcations of boundary value problems are global in nature and may not be related to any obvious change in dynamical behaviour. Catastrophe theory is a well-developed framework which studies the bifurcations of critical points of functions. In this paper we study the bifurcations of solutions of boundary-value problems for symplectic maps, using the language of (finite-dimensional) singularity theory. We associate certain such problems with a geometric picture involving the intersection of Lagrangian submanifolds, and hence with the critical points of a suitable generating function. Within this framework, we then study the effect of three special cases: (i) some common boundary conditions, such as Dirichlet boundary conditions for second-order systems, restrict the possible types of bifurcations (for example, in generic planar systems only the A-series beginning with folds and cusps can occur); (ii) integrable systems, such as planar Hamiltonian systems, can exhibit a novel periodic pitchfork bifurcation; and (iii) systems with Hamiltonian symmetries or reversing symmetries can exhibit restricted bifurcations associated with the symmetry. This approach offers an alternative to the analysis of critical points in function spaces, typically used in the study of bifurcation of variational problems, and opens the way to the detection of more exotic bifurcations than the simple folds and cusps that are often found in examples.

  13. Climate bifurcation during the last deglaciation?

    Directory of Open Access Journals (Sweden)

    T. M. Lenton

    2012-07-01

    Full Text Available There were two abrupt warming events during the last deglaciation, at the start of the Bølling-Allerød and at the end of the Younger Dryas, but their underlying dynamics are unclear. Some abrupt climate changes may involve gradual forcing past a bifurcation point, in which a prevailing climate state loses its stability and the climate tips into an alternative state, providing an early warning signal in the form of slowing responses to perturbations, which may be accompanied by increasing variability. Alternatively, short-term stochastic variability in the climate system can trigger abrupt climate changes, without early warning. Previous work has found signals consistent with slowing down during the last deglaciation as a whole, and during the Younger Dryas, but with conflicting results in the run-up to the Bølling-Allerød. Based on this, we hypothesise that a bifurcation point was approached at the end of the Younger Dryas, in which the cold climate state, with weak Atlantic overturning circulation, lost its stability, and the climate tipped irreversibly into a warm interglacial state. To test the bifurcation hypothesis, we analysed two different climate proxies in three Greenland ice cores, from the Last Glacial Maximum to the end of the Younger Dryas. Prior to the Bølling warming, there was a robust increase in climate variability but no consistent slowing down signal, suggesting this abrupt change was probably triggered by a stochastic fluctuation. The transition to the warm Bølling-Allerød state was accompanied by a slowing down in climate dynamics and an increase in climate variability. We suggest that the Bølling warming excited an internal mode of variability in Atlantic meridional overturning circulation strength, causing multi-centennial climate fluctuations. However, the return to the Younger Dryas cold state increased climate stability. We find no consistent evidence for slowing down during the Younger Dryas, or in a longer

  14. Transcatheter Aortic Valve Replacement by a Novel Suprasternal Approach.

    Science.gov (United States)

    Codner, Pablo; Pugliese, Daniel; Kouz, Rémi; Patel, Amisha; Chen, Cheng-Han; Terre, Juan; Eudailey, Kyle W; Nazif, Tamim; Vahl, Torsten P; George, Isaac; Khalique, Omar K; Hahn, Rebecca T; Leon, Martin B; Kodali, Susheel; Borger, Michael

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) provides therapy for patients with severe aortic stenosis at extreme, high, or intermediate surgical risk. Transfemoral access has been the preferred access route; however, this approach is not suitable for many TAVR candidates. A suprasternal approach may allow for earlier ambulation and shorter hospital stay as compared with other, nontransfemoral approaches. A total of 11 patients with unsuitable transfemoral access underwent suprasternal TAVR. Propensity matching was used to compare suprasternal patients to patients undergoing transaortic, transapical, and trans-subclavian TAVR. Groups were well matched for baseline characteristics. A self-expanding valve device was used in 6 (54.5%) and a balloon-expandable valve in 5 (45.5%) of the 11 patients treated by the suprasternal route. Suprasternal and trans-subclavian patients were able to ambulate earlier than patients treated by the transaortic route, a median 1.6 days (interquartile range [IQR]: 0.9 to 1.8), 1.6 days (IQR: 0.9 to 2.7), and 3.9 days (IQR: 1.9 to 4.5) after the procedure for suprasternal, trans-subclavian, and transaortic patients, respectively (p = 0.001). Length of hospitalization was shorter for patients treated by suprasternal or trans-subclavian access in comparison with patients treated by the transaortic or transapical approach: median 4 days (IQR: 3 to 8) and 4 days (IQR: 4 to 8) versus 8 days (IQR: 6 to 14) and 6 days (IQR: 7 to 11) for suprasternal and trans-subclavian versus transaortic and transapical, respectively (p = 0.01). Suprasternal and trans-subclavian access are associated with earlier ambulation and shorter hospitalization than other nontransfemoral TAVR routes, without an increase in complications. Further study is required to determine if suprasternal is the alternative access of choice for TAVR patients with poor transfemoral vasculature. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  15. Neonatal aortic stenosis.

    Science.gov (United States)

    Drury, Nigel E; Veldtman, Gruschen R; Benson, Lee N

    2005-09-01

    Neonatal aortic stenosis is a complex and heterogeneous condition, defined as left ventricular outflow tract obstruction at valvular level, presenting and often requiring treatment in the first month of life. Initial presentation may be catastrophic, necessitating hemodynamic, respiratory and metabolic resuscitation. Subsequent management is focused on maintaining systemic blood flow, either via a univentricular Norwood palliation or a biventricular route, in which the effective aortic valve area is increased by balloon dilation or surgical valvotomy. In infants with aortic annular hypoplasia but adequately sized left ventricle, the Ross-Konno procedure is also an attractive option. Outcomes after biventricular management have improved in recent years as a consequence of better patient selection, perioperative management and advances in catheter technology. Exciting new developments are likely to significantly modify the natural history of this disorder, including fetal intervention for the salvage of the hypoplastic left ventricle; 3D echocardiography providing better definition of valve morphology and aiding patient selection for a surgical or catheter-based intervention; and new transcutaneous approaches, such as duel beam echo, to perforate the valve.

  16. Bifurcations and Patterns in Nonlinear Dissipative Systems

    Energy Technology Data Exchange (ETDEWEB)

    Guenter Ahlers

    2005-05-27

    This project consists of experimental investigations of heat transport, pattern formation, and bifurcation phenomena in non-linear non-equilibrium fluid-mechanical systems. These issues are studies in Rayleigh-B\\'enard convection, using both pure and multicomponent fluids. They are of fundamental scientific interest, but also play an important role in engineering, materials science, ecology, meteorology, geophysics, and astrophysics. For instance, various forms of convection are important in such diverse phenomena as crystal growth from a melt with or without impurities, energy production in solar ponds, flow in the earth's mantle and outer core, geo-thermal stratifications, and various oceanographic and atmospheric phenomena. Our work utilizes computer-enhanced shadowgraph imaging of flow patterns, sophisticated digital image analysis, and high-resolution heat transport measurements.

  17. The bifurcations of nearly flat origami

    Science.gov (United States)

    Santangelo, Christian

    Self-folding origami structures provide one means of fabricating complex, three-dimensional structures from a flat, two-dimensional sheet. Self-folding origami structures have been fabricated on scales ranging from macroscopic to microscopic and can have quite complicated structures with hundreds of folds arranged in complex patterns. I will describe our efforts to understand the mechanics and energetics of self-folding origami structures. Though the dimension of the configuration space of an origami structure scales with the size of the boundary and not with the number of vertices in the interior of the structure, a typical origami structure is also floppy in the sense that there are many possible ways to assign fold angles consistently. I will discuss our theoretical progress in understanding the geometry of the configuration space of origami. For random origami, the number of possible bifurcations grows surprisingly quickly even when the dimension of the configuration space is small. EFRI ODISSEI-1240441, DMR-0846582.

  18. Transport Bifurcation in a Rotating Tokamak Plasma

    International Nuclear Information System (INIS)

    Highcock, E. G.; Barnes, M.; Schekochihin, A. A.; Parra, F. I.; Roach, C. M.; Cowley, S. C.

    2010-01-01

    The effect of flow shear on turbulent transport in tokamaks is studied numerically in the experimentally relevant limit of zero magnetic shear. It is found that the plasma is linearly stable for all nonzero flow shear values, but that subcritical turbulence can be sustained nonlinearly at a wide range of temperature gradients. Flow shear increases the nonlinear temperature gradient threshold for turbulence but also increases the sensitivity of the heat flux to changes in the temperature gradient, except over a small range near the threshold where the sensitivity is decreased. A bifurcation in the equilibrium gradients is found: for a given input of heat, it is possible, by varying the applied torque, to trigger a transition to significantly higher temperature and flow gradients.

  19. Bifurcated SEN with Fluid Flow Conditioners

    Directory of Open Access Journals (Sweden)

    F. Rivera-Perez

    2014-01-01

    Full Text Available This work evaluates the performance of a novel design for a bifurcated submerged entry nozzle (SEN used for the continuous casting of steel slabs. The proposed design incorporates fluid flow conditioners attached on SEN external wall. The fluid flow conditioners impose a pseudosymmetric pattern in the upper zone of the mold by inhibiting the fluid exchange between the zones created by conditioners. The performance of the SEN with fluid flow conditioners is analyzed through numerical simulations using the CFD technique. Numerical results were validated by means of physical simulations conducted on a scaled cold water model. Numerical and physical simulations confirmed that the performance of the proposed SEN is superior to a traditional one. Fluid flow conditioners reduce the liquid free surface fluctuations and minimize the occurrence of vortexes at the free surface.

  20. Oscillatory bifurcation for semilinear ordinary differential equations

    Directory of Open Access Journals (Sweden)

    Tetsutaro Shibata

    2016-06-01

    \\] where $f(u = u + (1/2\\sin^k u$ ($k \\ge 2$ and $\\lambda > 0$ is a bifurcation parameter. It is known that $\\lambda$ is parameterized by the maximum norm $\\alpha = \\Vert u_\\lambda\\Vert_\\infty$ of the solution $u_\\lambda$ associated with $\\lambda$ and is written as $\\lambda = \\lambda(k,\\alpha$. When we focus on the asymptotic behavior of $\\lambda(k,\\alpha$ as $\\alpha \\to \\infty$, it is natural to expect that $\\lambda(k, \\alpha \\to \\pi^2/4$, and its convergence rate is common to $k$. Contrary to this expectation, we show that $\\lambda(2n_1+1,\\alpha$ tends to $\\pi^2/4$ faster than $\\lambda(2n_2,\\alpha$ as $\\alpha \\to \\infty$, where $n_1\\ge 1,\\ n_2 \\ge 1$ are arbitrary given integers.

  1. Equilibrium-torus bifurcation in nonsmooth systems

    DEFF Research Database (Denmark)

    Zhusubahyev, Z.T.; Mosekilde, Erik

    2008-01-01

    Considering a set of two coupled nonautonomous differential equations with discontinuous right-hand sides describing the behavior of a DC/DC power converter, we discuss a border-collision bifurcation that can lead to the birth of a two-dimensional invariant torus from a stable node equilibrium...... point. We obtain the chart of dynamic modes and show that there is a region of parameter space in which the system has a single stable node equilibrium point. Under variation of the parameters, this equilibrium may disappear as it collides with a discontinuity boundary between two smooth regions...... in the phase space. The disappearance of the equilibrium point is accompanied by the soft appearance of an unstable focus period-1 orbit surrounded by a resonant or ergodic torus. Detailed numerical calculations are supported by a theoretical investigation of the normal form map that represents the piecewise...

  2. Clausius entropy for arbitrary bifurcate null surfaces

    International Nuclear Information System (INIS)

    Baccetti, Valentina; Visser, Matt

    2014-01-01

    Jacobson’s thermodynamic derivation of the Einstein equations was originally applied only to local Rindler horizons. But at least some parts of that construction can usefully be extended to give meaningful results for arbitrary bifurcate null surfaces. As presaged in Jacobson’s original article, this more general construction sharply brings into focus the questions: is entropy objectively ‘real’? Or is entropy in some sense subjective and observer-dependent? These innocent questions open a Pandora’s box of often inconclusive debate. A consensus opinion, though certainly not universally held, seems to be that Clausius entropy (thermodynamic entropy, defined via a Clausius relation dS=đQ/T) should be objectively real, but that the ontological status of statistical entropy (Shannon or von Neumann entropy) is much more ambiguous, and much more likely to be observer-dependent. This question is particularly pressing when it comes to understanding Bekenstein entropy (black hole entropy). To perhaps further add to the confusion, we shall argue that even the Clausius entropy can often be observer-dependent. In the current article we shall conclusively demonstrate that one can meaningfully assign a notion of Clausius entropy to arbitrary bifurcate null surfaces—effectively defining a ‘virtual Clausius entropy’ for arbitrary ‘virtual (local) causal horizons’. As an application, we see that we can implement a version of the generalized second law (GSL) for this virtual Clausius entropy. This version of GSL can be related to certain (nonstandard) integral variants of the null energy condition. Because the concepts involved are rather subtle, we take some effort in being careful and explicit in developing our framework. In future work we will apply this construction to generalize Jacobson’s derivation of the Einstein equations. (paper)

  3. Propagation of aortic dissection and visceral artery compromise. Three-dimensional analysis on CT angiography

    International Nuclear Information System (INIS)

    Minamiguchi, Hiroki

    2003-01-01

    The purpose of this study was to clarify the patterns of the propagation of aortic dissection with quantitative data from CT angiography and to verify the relationship between the propagation of aortic dissection and visceral artery compromise. The subjects were 67 cases (48 men, 19 women) with acute and subacute aortic dissection extending from the descending thoracic aorta to the aortic bifurcation. The mean age is 56.5±12.3 years old (range 34 to 80 years). Eight axial levels of the trunk of right pulmonary artery, left inferior pulmonary vein, coronary sinus, celiac axis, the orifice of superior mesenteric artery (SMA), the orifice of right real artery, the orifice of left renal artery and the orifice of inferior mesenteric artery were submitted to investigate the propagation of aortic dissection. The true lumen central angle was calculated in each level. The axial distance, branch angle difference and true distance between SMA and bilateral renal arteries were calculated. The trajectory of aortic dissection propagation from descending thoracic aorta to aortic bifurcation could be divided into two types of linear dissection type (n=41) and spiral dissection type (n=26). The latter were further subdivided into clockwise rotation type (n=14) and counter-clockwise rotation type (n=12). Younger age was significantly associated with the spiral dissection type as compared to older age (p=0.030). The spiral dissection type propagation pattern was found predominantly from the descending thoracic aorta to celiac axis, while at more distal levels linear type dissection was more common. The blood flow of SMA and celiac axis came from the true lumen or both lumens in all cases but single case from false lumen. The incidence (19.4%) of the right renal blood flow supplied from false lumen was lower than that (37.3%) of the left one supplied from false lumen. The shorter distance and the less angle difference between SMA and right renal artery than between SMA and left renal

  4. Esophageal leiomyoma in a dog causing esophageal distension and treated by transcardial placement of a self-expanding, covered, nitinol esophageal stent.

    Science.gov (United States)

    Robin, Elisabeth M; Pey, Pascaline B; de Fornel-Thibaud, Pauline; Moissonnier, Pierre H M; Freiche, Valérie

    2018-02-01

    CASE DESCRIPTION A 10-year-old spayed female Rottweiler was referred for evaluation because of a 2-month history of regurgitation and weight loss, despite no apparent change in appetite. The dog had received antiemetic and antacid treatment, without improvement. CLINICAL FINDINGS Physical examination revealed a low body condition score (2/5), but other findings were unremarkable. Diffuse, global esophageal dilatation was noted on plain thoracic radiographs, and normal motility was confirmed through videofluoroscopic evaluation of swallowing. Transhepatic ultrasonographic and CT examination revealed a circumferential, intraparietal lesion in the distal portion of the esophagus causing distal esophageal or cardial subobstruction and no metastases. Incisional biopsy of the lesion was performed, and findings of histologic examination supported a diagnosis of esophageal leiomyoma. TREATMENT AND OUTCOME In view of numerous possible complications associated with esophageal surgery, the decision was made to palliatively treat the dog by transcardial placement of a self-expanding, covered, nitinol esophageal stent under endoscopic guidance. Two weeks after stent placement, radiography revealed complete migration of the stent into the gastric lumen. Gastrotomy was performed, and the stent was replaced and fixed in place. Twenty-four months after initial stent placement, the dog had a healthy body condition and remained free of previous clinical signs. CLINICAL RELEVANCE Diffuse benign muscular neoplasia should be considered as a differential diagnosis for acquired esophageal dilatation in adult and elderly dogs. In the dog of this report, transcardial stent placement resulted in resolution of the clinical signs, with no apparent adverse effect on digestive function. The described procedure could be beneficial for nonsurgical treatment of benign esophageal tumors in dogs.

  5. SU-E-T-115: Dose Perturbation Study of Self-Expandable Metal and Polyester Esophageal Stents in Proton Therapy Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Li, Z [University of Florida Proton Therapy Institute, Jacksonville, FL (United States); Jalaj, S; McGaw, C; B K, John; J S, Scolapio; J C, Munoz [Division of Gastoenterology, Department of Medicine, University of Florida, Jacksonville, FL (United States)

    2014-06-01

    Purpose: This work investigates dose perturbations due to Self-expandable metal and polyester esophageal stents undergoing proton radiotherapy for esophageal cancer. Methods: Five commercially available esophageal stents made of nitinol (Evolution, Wallflex and Ultraflex), stainless steel (Z-Stent) and polyester (Polyflex) were tested. Radiochromic film (GafChromic EBT3 film, Ashland, Covington, KY) wrapped around a stent and a 12cc syringe was irradiated with 2CGE (Cobalt Gray Equivalent) of proton beam in a custom fabricated acrylic phantom. An air-hollow syringe simulates the esophagus. Results: The Z-stent created the largest dose perturbations ranges from -14.5% to 6.1% due to the steel composition. The WallFlex, Evolution and Ultraflex stents produced the dose perturbation ranges of (−9.2%∼8.6%), (−6.8%∼5.7%) and (−6.2%∼6.2%), respectively. The PolyFlex stent contains the radiopaque tungsten markers located top, middle and bottom portions. When the focal cold spots induced by the markers were excluded in the analysis, the dose perturbation range was changed from (−11.6%∼6.4%) to (−0.6%∼5.0%). Conclusion: The magnitude of dose perturbation is related to material of a metallic stent. The non-metallic stent such as PolyFlex shows relatively lower dose perturbation than metallic stents except a radiopaque marker region. Overall Evolution and Ultraflex stent appear to be less dose perturbations. The largest dose perturbations (cold spots) were located at both edges of stents in distal area for the single proton beam irradiation study. The analysis of more than two proton beam which is more typical clinical beam arrangement would be necessary to minimize the doe perturbation effect in proton ratiotherapy.

  6. Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

    International Nuclear Information System (INIS)

    Zhao, Jun-Gong; Li, Yong-Dong; Li, Ming-Hua; Shang, Ke-Zhong; Cheng, Ying-Sheng; Chen, Ni-Wei; Chen, Wei-Xiong

    2009-01-01

    To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4-5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n=4, 5.33%), chest pain (n=28, 38.7%), reflux (n=15, 20%), and bleeding (n=9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1-3, 3-5, 5-8, 8-10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 ± 0.28 years (95% CI: 2.25-3.35) and 4.28 ± 0.40 years (95% CI: 3.51-5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate. (orig.)

  7. Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jun-Gong; Li, Yong-Dong; Li, Ming-Hua; Shang, Ke-Zhong [Shanghai Tong Ji University, Department of Radiology, Tenth Affiliated People' s Hospital, Shanghai (China); Cheng, Ying-Sheng [Shanghai Tong Ji University, Department of Radiology, Tenth Affiliated People' s Hospital, Shanghai (China); Shanghai Jiao Tong University, Department of Radiology, Sixth Affiliated People' s Hospital, Shanghai (China); Chen, Ni-Wei; Chen, Wei-Xiong [Shanghai Jiao Tong University, Department of Gastroenterology, Sixth Affiliated People' s Hospital, Shanghai (China)

    2009-08-15

    To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4-5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n=4, 5.33%), chest pain (n=28, 38.7%), reflux (n=15, 20%), and bleeding (n=9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1-3, 3-5, 5-8, 8-10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 {+-} 0.28 years (95% CI: 2.25-3.35) and 4.28 {+-} 0.40 years (95% CI: 3.51-5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate. (orig.)

  8. Comparison of Laparoscopic versus Open Surgery after Insertion of Self-Expandable Metallic Stents in Acute Malignant Colorectal Obstruction: A Case-Matched Study

    Directory of Open Access Journals (Sweden)

    Chotirot Angkurawaranon

    2017-03-01

    Full Text Available Background: Self-expanding metallic stents (SEMS have been acknowledged in management of acute colorectal obstruction. The surgical approach after SEMS insertion varies from open approach to laparoscopic-assisted approach. The primary objective of this study was to compare the outcomes of laparoscopic approach and open approach after SEMS insertion. Methods: From January 2007 to December 2010, cross-sectional medical records reviewed a total of 76 patients who underwent colorectal stenting with SEMS. Patients and tumor characteristics, complications, morbidity and mortality were obtained. Results: Forty-three patients underwent SEMS placement as a bridge to surgery. Laparoscopic-assisted surgery (LS was performed in 24 patients (55.8%, and open surgery (OS was performed in 19 patients (44.2%. All clinicopathological parameters were matched. The technical success of SEMS was found in 42 patients (97.7%, and the clinical stent success was 100%. LS had a higher chance of primary anastomosis than OS (p=0.012; Odd ratio 2.717; 95%CI: 1.79-4.012. LS had a lower permanent ostomy rate (p=0.031; Odd ratio 0.385; 95%CI: 0.259-0.572 and lower estimated blood loss (p=0.024; Odd ratio 0.23; 95%CI: 0.006-0.086. The post-operative complications, mortality rate, recurrence rate, disease free status, and overall survival rates between the two groups were non-significant. Conclusion: Colonic stent is an effective treatment of acute malignant colonic obstruction. The authors suggest the advantage of laparoscopic approach resection after colonic stenting results in a higher primary anastomosis rate, and lower blood loss than open surgery.

  9. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  10. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study

    Science.gov (United States)

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin

    2016-01-01

    Background Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. Objective The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. Methods We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Results Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Conclusions Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months. PMID:28507752

  11. Management of pancreatic collections with a novel endoscopically placed fully covered self-expandable metal stent: a national experience (with videos).

    Science.gov (United States)

    Chandran, Sujievvan; Efthymiou, Marios; Kaffes, Arthur; Chen, John Wei; Kwan, Vu; Murray, Michael; Williams, David; Nguyen, Nam Quoc; Tam, William; Welch, Christine; Chong, Andre; Gupta, Saurabh; Devereaux, Ben; Tagkalidis, Peter; Parker, Frank; Vaughan, Rhys

    2015-01-01

    Recent medical literature on novel lumen-apposing stents for the treatment of pancreatic fluid collections (PFCs) is limited by small numbers, solo operators, and single-center experience. To evaluate a recently developed lumen-apposing, fully covered self-expandable metal stent (FCSEMS) in the management of PFCs. Retrospective case series. Thirteen tertiary and private health care centers across Australia. Forty-seven patients (median age 51 years) who underwent endoscopic management of PFCs. Insertion of FCSEMS after PFC puncture under EUS guidance. A subgroup of 9 patients underwent direct endoscopic necrosectomy. Technical and clinical success rate, adverse event rate. The technical success rate was 53 of 54 patients (98.1%), and the initial clinical success rate was 36 of 47 (76.6%), which was sustained for more than 6 months in 34 of 36 (94.4%). Early adverse events included 4 cases (7.4%) of stent migration during direct endoscopic necrosectomy, 4 cases (7.4%) of sepsis, 1 case (1.9%) of bleeding, and 1 case (1.9%) of stent migration into the fistula tract. Late adverse events were 6 (11.1%) spontaneous stent migrations, 3 (5.6%) recurrent stent occlusions, 3 (5.6%) tissue ingrowth/overgrowth, and 2 (3.7%) bleeding into PFC. The majority of stents inserted (48 of 54, 88.9%) and removed (31 of 35, 88.6%) in our study were described by the operator as superior to pigtail stents with regard to ease of use. Retrospective study. Although FCSEMSs are technically easier to insert and remove compared with traditional pigtail stents, there are significant limitations to the widespread use of FCSEMSs in the management of PFCs. These include cost, adverse events, and lower-than-expected resolution rates. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients.

    Science.gov (United States)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G; Goldberg, Paul; Casellas, Juan A; Roncero, Oscar; Grund, Karl E; Alvarez, Alberto; García-Cano, Jesús; Vázquez-Astray, Enrique; Jiménez-Pérez, Javier

    2011-10-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery. To document performance, safety, and effectiveness of colorectal stents used per local standards of practice in patients with malignant large-bowel obstruction to avoid palliative stoma surgery in incurable patients (PAL) and facilitate bowel decompression as a bridge to surgery for curable patients (BTS). Prospective clinical cohort study. Two global registries with 39 academic and community centers. This study involved 447 patients with malignant colonic obstruction who received stents (255 PAL, 182 BTS, 10 no indication specified). Colorectal through-the-scope SEMS placement. The primary endpoint was clinical success at 30 days, defined as the patient's ability to maintain bowel function without adverse events related to the procedure or stent. Secondary endpoints were procedural success, defined as successful stent placement in the correct position, symptoms of persistent or recurrent colonic obstruction, and complications. The procedural success rate was 94.8% (439/463), and the clinical success rates were 90.5% (313/346) as assessed on a per protocol basis and 71.6% (313/437) as assessed on an intent-to-treat basis. Complications included 15 (3.9%) perforations, 3 resulting in death, 7 (1.8%) migrations, 7 (1.8%) cases of pain, and 2 (0.5%) cases of bleeding. No control group. No primary endpoint analysis data for 25% of patients. This largest multicenter, prospective study of colonic SEMS placement demonstrates that colonic SEMSs are safe and highly effective for the short-term treatment of malignant colorectal obstruction, allowing most curable patients to have 1-step resection without stoma and providing most incurable patients minimally invasive palliation instead of surgery. The risk of complications, including perforation, was low. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All

  13. Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction: A randomized controlled trial.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Yoo, Byung Moo; Hwang, Jae Chul; Yoo, Jun Hwan; Lee, Ki Seong; Kang, Joon Koo; Kim, Soon Sun; Lim, Sun Gyo; Shin, Sung Jae; Cheong, Jae Youn; Lee, Kee Myung; Lee, Kwang Jae; Cho, Sung Won

    2015-01-01

    Covered self-expandable metal stents (SEMSs) are increasingly used as alternatives to uncovered SEMSs for the palliation of inoperable malignant distal biliary obstruction to counteract tumor ingrowth. We aimed to compare the outcomes of partially covered and uncovered SEMSs with identical mesh structures and anti-migration properties, such as low axial force and flared ends. One hundred and three patients who were diagnosed with inoperable malignant distal biliary obstruction between January 2006 and August 2013 were randomly assigned to either the partially covered (n = 51) or uncovered (n = 52) SEMS group. There were no significant differences in the cumulative stent patency, overall patient survival, stent dysfunction-free survival and overall adverse events, including pancreatitis and cholecystitis, between the two groups. Compared to the uncovered group, stent migration (5.9% vs. 0%, p = 0.118) and tumor overgrowth (7.8% vs. 1.9%, p = 0.205) were non-significantly more frequent in the partially covered group, whereas tumor ingrowth showed a significantly higher incidence in the uncovered group (5.9% vs. 19.2%, p = 0.041). Stent migration in the partially covered group occurred only in patients with short stenosis of the utmost distal bile duct (two in ampullary cancer, one in bile duct cancer), and did not occur in any patients with pancreatic cancer. For the palliation of malignant distal biliary obstruction, endoscopic placement of partially covered SEMSs with anti-migration designs and identical mesh structures to uncovered SEMSs failed to prolong cumulative stent patency or reduce stent migration.

  14. Influence of K-ras status and anti-tumour treatments on complications due to colorectal self-expandable metallic stents: a retrospective multicentre study.

    Science.gov (United States)

    Fuccio, Lorenzo; Correale, Loredana; Arezzo, Alberto; Repici, Alessandro; Manes, Gianpiero; Trovato, Cristina; Mangiavillano, Benedetto; Manno, Mauro; Cortelezzi, Claudio Camillo; Dinelli, Marco; Cennamo, Vincenzo; de Bellis, Mario

    2014-06-01

    This study aimed to explore the relationship between K-ras status, anti-tumour treatments, and the complications of colorectal self-expandable metallic stenting in colorectal cancer. This is a retrospective, multicentre study of 91 patients with obstructive advanced colorectal cancer palliated with enteral stents between 2007 and 2011. K-ras wild-type tumours were diagnosed in 44 patients (48.4%); 82 (90.1%) received chemotherapy and 45 (49.4%) had additional biological therapy (34 bevacizumab, 11 cetuximab). Twenty-one (23.1%) experienced stent-related complications: 11 (52.4%) occurred in the K-ras mutant group (P=0.9). K-ras wild-type patients were not less likely to develop adverse events than K-ras mutant patients (OR, 0.99; 95% CI: 0.4-2.7). Overall mean time to complication was 167.6 days (range 4-720 days), with no difference between the two groups (141 vs. 197 days; P=0.5). Chemotherapy did not influence the risk of complications (OR, 0.56; 95% CI: 0.14-2.9), and there was no evidence that patients treated with chemotherapy and cetuximab were more likely to experience stent-related complications than patients treated with chemotherapy alone, or untreated (OR, 1.2; 95% CI: 0.2-5.9). Although perforation rates were higher with bevacizumab-based treatment (11.8% vs. 7%), this result was not statistically significant (P=0.69). K-ras mutation status, chemotherapy, and biological treatments should not influence colorectal stent-related complication rates. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.

    Science.gov (United States)

    Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma

    2015-07-01

    The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.

  16. A prospective multicenter study on self-expandable metallic stents as a bridge to surgery for malignant colorectal obstruction in Japan: efficacy and safety in 312 patients.

    Science.gov (United States)

    Saito, Shuji; Yoshida, Shuntaro; Isayama, Hiroyuki; Matsuzawa, Takeaki; Kuwai, Toshio; Maetani, Iruru; Shimada, Mamoru; Yamada, Tomonori; Tomita, Masafumi; Koizumi, Koichi; Hirata, Nobuto; Kanazawa, Hideki; Enomoto, Toshiyuki; Sekido, Hitoshi; Saida, Yoshihisa

    2016-09-01

    Endoscopic stenting with a self-expandable metallic stent (SEMS) is a widely accepted procedure for malignant colonic obstruction. The Colonic Stent Safe Procedure Research Group conducted the present prospective feasibility study. Our objectives were to estimate the safety and feasibility of SEMS placement as a bridge to surgery (BTS) for malignant colorectal obstruction. We conducted a prospective, observational, single-arm, multicenter clinical trial from March 2012 to October 2013. Each patient was treated with an uncovered WallFlex enteral colonic stent. Patients were followed up until discharge after surgery. A total of 518 consecutive patients were enrolled in this study. The cohort intended for BTS consisted of 312 patients (61 %), and the stent could be released in 305 patients. Technical and clinical success rates were 98 and 92 %, respectively. Elective surgery was performed in 297 patients, and emergency surgery was performed in eight patients for the treatment of complications. The overall preoperative complication rate was 7.2 %. Major complications, including perforation, occurred in 1.6 %, persistent colonic obstruction occurred in 1.0 %, and stent migration occurred in 1.3 % patients. The median time from SEMS to surgery was 16 days. Silent perforations were observed in 1.3 %. Open and laparoscopic surgery was performed in 121 and 184 patients, respectively. The tumor could be resected in 297 patients. The primary anastomosis rate was 92 %. The rate of anastomotic leakage was 4 %, and the overall stoma creation rate was 10 %. The median duration of hospitalization following surgery was 12 days. Overall postoperative morbidity and mortality rates were 16 and 0.7 %, respectively. This largest, multicenter, prospective study demonstrates the feasibility of SEMS placement as a BTS for malignant colorectal obstruction. SEMS serves as a safe and effective BTS with acceptable stoma creation and complication rates in patients with acute

  17. A US Multicenter Study of Safety and Efficacy of Fully Covered Self-Expandable Metallic Stents in Benign Extrahepatic Biliary Strictures.

    Science.gov (United States)

    Saxena, Payal; Diehl, David L; Kumbhari, Vivek; Shieh, Frederick; Buscaglia, Jonathan M; Sze, Wilson; Kapoor, Sumit; Komanduri, Srinadh; Nasr, John; Shin, Eun Ji; Singh, Vikesh; Lennon, Anne Marie; Kalloo, Anthony N; Khashab, Mouen A

    2015-11-01

    Endoscopic therapy is considered first line for management of benign biliary strictures (BBSs). Placement of plastic stents has been effective but limited by their short-term patency and need for repeated procedures. Fully covered self-expandable metallic stents (FCSEMSs) offer longer-lasting biliary drainage without the need for frequent exchanges. The aim of this study was to assess the efficacy and safety of FCSEMS in patients with BBS. A retrospective review of all patients who underwent ERCP and FCSEMS placement at five tertiary referral US hospitals was perfor