WorldWideScience

Sample records for anterior capsule phimosis

  1. [Posterior capsule opacification, capsular bag distension syndrome, and anterior capsular phimosis: A retrospective cohort study].

    Science.gov (United States)

    González-Martín-Moro, J; González-López, J J; Gómez-Sanz, F; Zarallo-Gallardo, J; Cobo-Soriano, R

    2015-02-01

    To determine the incidence and the risk factors involved in the development of the three main postoperative capsular complications: posterior capsule opacification (PCO), capsular bag distension syndrome (CBDS), and anterior capsular phimosis syndrome (ACP). A retrospective cohort study was conducted on 801 patients submitted to cataract surgery in the ophthalmology unit of Hospital del Henares (Madrid) from March 2, 2009 to February 28, 2010. Computerized clinical charts were reviewed during July 2012. PCO was studied using the Kaplan-Meier method (log rank test). A total of 167 patients developed PCO. No association could be demonstrated between PCO and age, sex, diabetes mellitus, phaco technique, IOL model, tamsulosin intake, glaucoma, and age-related macular degeneration. Three patients developed CBDS, all of them have received and Akreos Adapt AO(®) (Bausch & Lomb). Two of them were young men who had received surgery for posterior subcapsular cataracts. Three patients developed ACP, 2 of whom had received a MicroSlim(®) IOL (PhysIOL). No association was found between PCO and any of the studied variables. Male gender, young age, subcapsular cataract and large non-angulated lens such as Akreos Adapt AO(®) could be associated with CBDS. ACP could be more frequent when microincision IOLs (like MicroSlim(®)) are implanted. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Capsular phimosis with complete occlusion of the anterior capsular opening after intact continuous curvilinear capsulorrhexis

    International Nuclear Information System (INIS)

    AlKharashi, Soliman A

    2009-01-01

    Shrinkage and whitening of the anterior capsule opening - capsular contraction syndrome - is a well-known complication after continuous curvilinear capsulorrhexis. A 72-year-old women underwent continuous curvilinear capsulorrhexis, phacoemulsification, and implantation of posterior chamber intraocular lens with polymethylmethacrylate haptics. Four months postoperatively, the patient reported deterioration in visual acuity that was resulted due to complete occlusion of anterior capsular opening by fibrotic tissue. The fibrous membrane was excised surgically in capsulorrhexis fashion. (author)

  3. Reduced anterior internal capsule white matter integrity in primary insomnia.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Prem, Martin; Baglioni, Chiara; Nissen, Christoph; Feige, Bernd; Schnell, Susanne; Kiselev, Valerij G; Hennig, Jürgen; Riemann, Dieter

    2014-07-01

    Chronic insomnia is one of the most prevalent central nervous system diseases, however, its neurobiology is poorly understood. Up to now, nothing is known about the integrity of white matter tracts in insomnia patients. In this study, diffusion tensor imaging (DTI) was used in a well-characterized sample of primary insomnia (PI) patients and good sleeper controls to fill this void. Voxelwise between-group comparisons of fractional anisotropy (FA) were performed in 24 PI patients (10 males; 14 females; 42.7 ± 14.5 years) and 35 healthy good sleepers (15 males; 20 females; 40.1 ± 9.1 years) with age and sex as covariates. PI patients showed reduced FA values within the right anterior internal capsule and a trend for reduced FA values in the left anterior internal capsule. The results suggest that insomnia is associated with a reduced integrity of white matter tracts in the anterior internal capsule indicating that disturbed fronto-subcortical connectivity may be a cause or consequence of the disorder.

  4. Leg and Femoral Neck Length Evaluation Using an Anterior Capsule Preservation Technique in Primary Direct Anterior Approach Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Stephen J Nelson

    2017-04-01

    Full Text Available Background Achieving correct leg and femoral neck lengths remains a challenge during total hip arthroplasty (THA.  Several methods for intraoperative evaluation and restoration of leg length have been proposed, and each has inaccuracies and shortcomings.  Both the supine positioning of a patient on the operating table during the direct anterior approach (DAA THA and the preservation of the anterior capsule tissue  are simple, readily available, and cost-effective strategies that can lend themselves well as potential solutions to this problem. Technique The joint replacement is performed through a longitudinal incision (capsulotomy of the anterior hip joint capsule, and release of the capsular insertion from the femoral intertrochanteric line. As trial components of the prosthesis are placed, the position of the released distal capsule in relationship to its original insertion line is an excellent guide to leg length gained, lost, or left unchanged. Methods The radiographs of 80 consecutive primary THAs were reviewed which utilized anterior capsule preservation and direct capsular measurement as a means of assessing change in leg/femoral neck length. Preoperatively, the operative legs were 2.81 +/- 8.5 mm (SD shorter than the nonoperative leg (range: 17.7 mm longer to 34.1 mm shorter.  Postoperatively, the operative legs were 1.05 +/- 5.64 mm (SD longer than the nonoperative leg (range: 14.9 mm longer to 13.7 mm shorter. Conclusion The preservation and re-assessment of the native anterior hip capsule in relationship to its point of release on the femur is a simple and effective means of determining leg/femoral neck length during DAA THA.

  5. Anterior joint capsule of the normal hip and in children with transient synovitis: US study with anatomic and histologic correlation

    NARCIS (Netherlands)

    S.G.F. Robben (Simon); M.H. Lequin (Maarten); A.F.M. Diepstraten (Ad); J.C. den Hollander (Jan); C.A. Entius; M. Meradji

    1999-01-01

    textabstractPURPOSE: To study the anatomic components of the anterior joint capsule of the normal hip and in children with transient synovitis. MATERIALS AND METHODS: Six cadaveric specimens were imaged with ultrasonography (US) with special attention to the anterior

  6. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    Directory of Open Access Journals (Sweden)

    Giammaria D

    2013-01-01

    Full Text Available Daniele Giammaria,1 Michele Giannotti,2 Angelo Scopelliti,1 Giacomo Pellegrini,1 Bruno Giannotti11Azienda Ospedaliera Ospedali Riuniti Marche Nord, Fano, Italy; 2Catholic University of Rome, Rome, ItalyAbstract: The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances to increase the stability of the anterior chamber and to dose the injected dye have been described. The authors present an under-air staining technique of the anterior capsule using one drop of Trypan blue injected with a 30 G needle through the peripheral cornea. This procedure prevents the air bubble from escaping the anterior chamber and allows fast and selective staining of the capsule.Keywords: Trypan blue, staining technique, dye, cataract surgery, capsulorhexis

  7. The method for staining of anterior lens capsule in cases with small and rigid pupils

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2012-01-01

    Full Text Available Purpose: to evaluate the safety and effectiveness of proposed method for staining with trypan blue anterior lens capsule in cases with small and rigid pupils.Methods: the safety and effectiveness of the proposed method was evaluated in 169 cases having small and rigid pupils of III and IV grade. Surgical steps included: irrigation of anterior chamber with small amount of air, enough to block the pupil; irrigation of posterior chamber with little amount of dye followed by aspiration of air bubble. the excess dye came out and stained the capsule in pupillary area.Results: No difficulty was encountered in irrigating the posterior chamber with dye. Uneven staining of the capsule was noticed in 16 cases (9.5%. In 3 cases (1.8% extensive staining of iris and posterior capsule was observed. Continuous curvilinear capsulorhexis was performed successfully in 97.6% cases. In 4 cases there was radial run of the rhexis extending up to posterior capsule. Postopera- tive inflammation of 1st and 2nd degree was observed in 5.9 and 23.1% cases, which was related to unavoidable trauma to iris tissue during pupil stretching.Conclusion: the proposed method of capsule staining in cases with small and rigid pupils is safe and effective.

  8. The method for staining of anterior lens capsule in cases with small and rigid pupils

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2014-07-01

    Full Text Available Purpose: to evaluate the safety and effectiveness of proposed method for staining with trypan blue anterior lens capsule in cases with small and rigid pupils.Methods: the safety and effectiveness of the proposed method was evaluated in 169 cases having small and rigid pupils of III and IV grade. Surgical steps included: irrigation of anterior chamber with small amount of air, enough to block the pupil; irrigation of posterior chamber with little amount of dye followed by aspiration of air bubble. the excess dye came out and stained the capsule in pupillary area.Results: No difficulty was encountered in irrigating the posterior chamber with dye. Uneven staining of the capsule was noticed in 16 cases (9.5%. In 3 cases (1.8% extensive staining of iris and posterior capsule was observed. Continuous curvilinear capsulorhexis was performed successfully in 97.6% cases. In 4 cases there was radial run of the rhexis extending up to posterior capsule. Postopera- tive inflammation of 1st and 2nd degree was observed in 5.9 and 23.1% cases, which was related to unavoidable trauma to iris tissue during pupil stretching.Conclusion: the proposed method of capsule staining in cases with small and rigid pupils is safe and effective.

  9. Lenticonus diagnosis in Alport's syndrome: Anterior capsule apical angle calculation using Scheimpflug imagery.

    Science.gov (United States)

    Jarrín, E; Jarrín, I; Arnalich-Montiel, F

    2015-08-01

    We describe a simplified method to detect anterior lenticonus. Three eyes of 2 patients with anterior lenticonus, plus 16 eyes from 16 healthy controls underwent Scheimpflug imaging of their anterior segment with Pentacam. The anterior capsule apex angle was manually identified and automatically measured by AutoCAD. The mean angle was 173.06° (SD: 1.91) in healthy subjects, and 158.33° (SD: 3.05) in anterior lenticonus eyes. The angle obtained from patients was more than 3 SD steeper than those from healthy subjects. The apical angle calculation method seems to discriminate well between normal eyes and eyes suspected of having anterior lenticonus. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Stability of capsule closure and postoperative anterior knee pain after medial parapatellar approach in TKA.

    Science.gov (United States)

    Keshmiri, Armin; Dotzauer, Fabian; Baier, Clemens; Maderbacher, Günther; Grifka, Joachim; Sendtner, Ernst

    2017-07-01

    Anterior knee pain after total knee arthroplasty (TKA) remains a widely discussed postoperative complication. In contrast to sports traumatology, the role of the dissected medial patellofemoral ligament (MPFL) using a medial parapatellar approach in TKA has not been discussed so far. In the present study, it was hypothesized that the attempted repair of the MPFL in TKA by simple closure of the joint capsule may not be successful in some cases, causing anterior knee pain. Furthermore, it was hypothesized, that the success of repair might be influenced by femoral component rotation. Forty patients received their TKA in a ligament-balanced and forty patients in a conventional measured-resection technique. After implantation of the TKA using a medial parapatellar approach, two titan clips were attached on both sides of the capsule incision. 3 days and 3 months after surgery, the dehiscence of the two clips was measured on skyline patella radiographs; additionally patellar tilt, shift, the Knee Society Score and the Feller Score were obtained. 48 patients showed an increase of capsule dehiscence. Patients with a capsule dehiscence of more than 4 mm showed significantly less improvement in the Feller score 3 months postoperatively than patients with a capsule dehiscence ≤4 mm. Regarding the radiological measurements and the clinical outcome, no significant difference between the ligament-balanced and the measured-resection group was found. The present results suggest that the successful repair of the MPFL after using a medial parapatellar approach in TKA could reduce the high rate of postoperative anterior knee pain. Furthermore, the appearance of capsule dehiscence and anterior knee pain does not seem to be dependent on the used operative technique.

  11. Treatment Approach to Small Inadvertent Injury of the Crystalline Lens Anterior Capsule During Iridodialysis Repair Surgery

    Directory of Open Access Journals (Sweden)

    Gökçen Gökçe

    2013-01-01

    Full Text Available A 22-year-old man presented to our ophthalmology department with photophobia. On ophthalmic examination, iridodialysis secondary to blunt trauma that occurred 5 years ago was diagnosed. During iridodialysis repair surgery, long curved double-armed needle of 10-0 polypropylene suture (PC-9 inserted into the 19 gauge side port turned down inadvertently by its own weight, resulting in crystalline lens anterior capsule perforation. Postoperative clinical observation revealed no lens opacification affecting visual acuity. This case report showed that lens aspiration surgery should be postponed if the capsule injury is small.(Turk J Ophthalmol 2013; 43: 61-3

  12. Innervation of the Anterior Capsule of the Human Knee: Implications for Radiofrequency Ablation.

    Science.gov (United States)

    Franco, Carlo D; Buvanendran, Asokumar; Petersohn, Jeffrey D; Menzies, Robert D; Menzies, Linda Pham

    2015-01-01

    Chronic knee pain is common in all age groups. Some patients who fail conservative therapy benefit from radiofrequency neurotomy. Knowledge of the anatomy is critical to ensure a successful outcome. The purpose of this study was to reanalyze the innervation to the anterior knee capsule from the perspective of the interventional pain practitioner. The study included a comprehensive literature review followed by dissection of 8 human knees to identify the primary capsular innervation of the anterior knee joint. Photographs and measurements were obtained for each relevant nerve branch. Stainless-steel wires were placed along the course of each primary innervation, and radiographs were obtained. Literature review revealed a lack of consensus on the number and origin of nerve branches innervating the anterior knee capsule. All dissections revealed the following 6 nerves: superolateral branch from the vastus lateralis, superomedial branch from the vastus medialis, middle branch from the vastus intermedius, inferolateral (recurrent) branch from the common peroneal nerve, inferomedial branch from the saphenous nerve, and a lateral articular nerve branch from the common peroneal nerve. Nerve branches showed variable proximal trajectories but constant distal points of contact with femur and tibia. The inferolateral peroneal nerve branch was found to be too close to the common peroneal nerve, making it inappropriate for radiofrequency neurotomy. The innervation of the anterior capsule of the knee joint seems to follow a constant pattern making at least 3 of these nerves accessible to percutaneous ablation. To optimize clinical outcome, well-aligned radiographs are critical to guide lesion placement.

  13. Inner Synovial Membrane Footprint of the Anterior Elbow Capsule: An Arthroscopic Boundary

    Directory of Open Access Journals (Sweden)

    Srinath Kamineni

    2015-01-01

    Full Text Available Introduction. The purpose of this study is to describe the inner synovial membrane (SM of the anterior elbow capsule, both qualitatively and quantitatively. Materials and Methods. Twenty-two cadaveric human elbows were dissected and the distal humerus and SM attachments were digitized using a digitizer. The transepicondylar line (TEL was used as the primary descriptor of various landmarks. The distance between the medial epicondyle and medial SM edge, SM apex overlying the coronoid fossa, the central SM nadir, and the apex of the SM insertion overlying the radial fossa and distance from the lateral epicondyle to lateral SM edge along the TEL were measured and further analyzed. Gender and side-to-side statistical comparisons were calculated. Results. The mean age of the subjects was 80.4 years, with six male and five female cadavers. The SM had a distinctive double arched attachment overlying the radial and coronoid fossae. No gender-based or side-to-side quantitative differences were noted. In 18 out of 22 specimens (81.8%, an infolding extension of the SM was observed overlying the medial aspect of the trochlea. The SM did not coincide with the outer fibrous attachment in any specimen. Conclusion. The humeral footprint of the synovial membrane of the anterior elbow capsule is more complex and not as capacious as commonly understood from the current literature. The synovial membrane nadir between the two anterior fossae may help to explain and hence preempt technical difficulties, a reduction in working arthroscopic volume in inflammatory and posttraumatic pathologies. This knowledge should allow the surgeon to approach this aspect of the anterior elbow compartment space with the confidence that detachment of this synovial attachment, to create working space, does not equate to breaching the capsule. Alternatively, stripping the synovial attachment from the anterior humerus does not constitute an anterior capsular release.

  14. 25G posterior capsulotomy with anterior vitrectomy for posterior capsule opacification

    Directory of Open Access Journals (Sweden)

    Ying-Jie Lin

    2014-03-01

    Full Text Available AIM: To evaluate the efficacy and complications of 25G posterior capsulotomy with anterior vitrectomy for posterior capsule opacification(PCO. METHODS: The 25G transconjunctival sutureless vitrectomy technique was performed in 48 cases(68 eyesof PCO eyes. The mean follow-up was 24mo. Best-corrected visual acuity(BCVA, intraocular pressure, anterior chamber reaction and complications during and after the operation were observed. RESULTS: 4mm diameter round holes were obtained at the center of the posterior capsule in all eyes. At 1d postoperative, uncorrected visual acuity(UCVAwas 0.70±0.12(0.5-1.0, and BCVA was 0.73±0.10(0.6-1.0. At 3mo postoperative, UCVA was 0.72±0.12(0.5-1.0, and BCVA was 0.74±0.10(0.6-1.0. It was statistical significance between preoperative and postoperative UCVA(t=-45.902, P=0.000. There were no complications during the postoperative follow-up period, such as dislocation or damage of the IOL, corneal edema, endoophthalmitis, pupil vitreous hernia, vitreous prolapse, retina detachment, intraocular hypertension and reocclusion of the visual axis, etc.CONCLUSION: The 25G transconjunctival sutureless vitrectomy technique to remove PCO is a safe and effective procedure with less complications, which can be an alternative treatment for PCO.

  15. Late anterior traumatic subluxation of a circular in-the-bag intraocular lens associated with lack of posterior capsule opacification.

    Science.gov (United States)

    Billotte, Christian; Stéfani, Pierre; Lecoq, Pierre

    2003-05-01

    We report a case of traumatic subluxation of a circular poly(methyl methacrylate) intraocular lens (IOL) 5 years after surgery. Slitlamp examination revealed the lack of epithelial cells or fibrosis in the intact capsule bag. Trauma was minor, and no other complication was found in the eye and orbit. The subluxated IOL was easily relocated in the bag with a hook, revealing the poor capsule sealing. Among the factors ensuring the fixation of IOLs placed in the bag after continuous curvilinear capsulotomy are sealing of the anterior and posterior capsules and proliferation of epithelial cells from the equator of the bag.

  16. Pure dysarthria due to anterior internal capsule and/or corona radiata infarction: a report of five cases.

    Science.gov (United States)

    Ozaki, I; Baba, M; Narita, S; Matsunaga, M; Takebe, K

    1986-01-01

    Five cases with a sudden onset of dysarthria in the setting of hypertension are presented. No case had limb weakness or other neurological deficits. Computed tomographic scan demonstrated a small low density lesion in the anterior part of the internal capsule or the adjacent corona radiata. All cases showed a good recovery from dysarthria within two to four weeks. Images PMID:3806121

  17. Observation time and spontaneous resolution of primary phimosis in children

    Directory of Open Access Journals (Sweden)

    Pedro Luiz Toledo de Arruda Lourenção

    Full Text Available ABSTRACT Objective: to investigate spontaneous resolution rate of a series of patients with physiologic phimosis in relation to observation time and presence of symptoms. Methods: retrospective and longitudinal follow-up study of patients with physiologic phimosis, that did not apply topic treatment. These patients were invited for a new visit for reevaluation, or recent data were obtained by chart analysis. Spontaneous resolution rate was determined and statistically compared to age, presence of symptoms at first medical visit and time until reevaluation. Results: seventy one patients were included. Medium time of observation from first visit to reevaluation was 37.4 months. There was spontaneous resolution of phimosis in 32 (45% patients. Children with spontaneous resolution were younger at initial diagnosis and were observed during a longer period of time. Most asymptomatic patients at first visit presented spontaneous resolution. However, it was not possible to stablish a significant relationship between presence of symptoms and evolution of physiologic phimosis. Conclusions: time of observation was the main determinant of spontaneous resolution of patients with physiologic phimosis, reinforcing the current more conservative approach regarding circumcision of those patients.

  18. Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery

    Directory of Open Access Journals (Sweden)

    Txomin Alberdi

    2018-04-01

    Full Text Available AIM: To analyze and compare five different variables over one year follow-up (1wk, 1, 3, 6 and 12mo: anterior capsule (AC, and posterior capsule (PC area densitometry values, AC and PC linear densitometry values, and AC opening area reduction ratio after femtosecond laser-assisted cataract surgery. METHODS: This was a prospective comparative study. Seventy-one patients underwent femtosecond laser-assisted cataract surgery on single eye between June 2014 and December 2015. A 5.0 mm diameter laser assisted anterior capsulotomy was performed on all eyes. In every post-surgery evaluation, AC opacificaction (ACO and PC opacification (PCO density levels were provided by Oculus Pentacam®HR using area and linear densitometry methods. Digital images were captured with a slit-lamp Topcon photographic camera and IMAGEnet® 5 software. The AC opening area on the digital images was measured using the Sketchandcalc area calculator and converted to reduction ratio levels. RESULTS: Using Pearson correlation coefficient (PCC, we found no correlation (r=-0.091, P=0.46 in the twelfth month assessment between the evolution of ACO area densitometry values and PCO area densitometry values considered as independent variables. We found no correlation, using PCC (r=-0.096, P=0.43 between the evolution of ACO linear densitometry values and PCO linear densitometry values, in the twelfth month visit, working both as independent variables. AC linear densitometry levels and AC area densitometry levels continued to grow strongly from sixth to twelfth months. Analysis of the values of AC opening area reduction ratio (1wk, 1, 3, 6, 12mo revealed statistically significant differences between the values of successive examinations but the magnitude of the change decreased. In the final period of monitoring between six and twelve months the magnitude of change was low. CONCLUSION: Our results show strong increases of Scheimpflug ACO densitometry values from the sixth to the

  19. Relation of the radial nerve to the anterior capsule of the elbow: anatomy with correlation to arthroscopy.

    Science.gov (United States)

    Omid, Reza; Hamid, Nady; Keener, Jay D; Galatz, Leesa M; Yamaguchi, Ken

    2012-12-01

    To determine the location and proximity of the radial nerve to the anterior capsule and to delineate and describe the anatomy of the brachialis as it relates to the radial nerve and anterior capsule. Arthroscopy was performed on 24 cadavers using only a standard anteromedial portal. A Beath pin was placed laterally, entering the joint at the most lateral edge of the radiocapitellar joint space, and a suture was placed through the pin and into the joint for reference during the dissection. The second phase was to perform open anatomic dissections. We found that in all specimens the radial nerve coursed longitudinally medial to the capitellum. The brachialis muscle was found to lie between the radial nerve and the joint capsule at the joint line and all proximal levels. Only at the most distal aspect of the joint line (corresponding to the level of the radial neck) did the nerve run in direct contact with the capsule in 11 specimens (55%). The brachialis muscle thickness was 4 mm or greater at the joint line and at all proximal measurement points. We found that the radial nerve is more medially located than previously thought. At the level of the radiocapitellar joint line, the radial nerve runs medial to the capitellum. The brachialis muscle lies between the radial nerve and the joint capsule at the level of the joint line and proximally. Arthroscopic capsular release laterally should be performed at the level of the joint line or above. The most dangerous area for capsular resection is distally over the radial head/neck, where 50% of our specimens had no brachialis protecting the nerve. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Randomized Controlled Trial for Efficacy of Capsular Distension for Adhesive Capsulitis: Fluoroscopy-Guided Anterior Versus Ultrasonography-Guided Posterolateral Approach

    OpenAIRE

    Bae, Jae Hyun; Park, Young Sook; Chang, Hyun Jung; Kim, Min Jung; Park, Kang Young; Jin, Seung Hwan; Lee, Eun Hee

    2014-01-01

    Objective To find the most effective procedure to treat adhesive capsulitis of the shoulder, we evaluated the clinical effects of an ultrasonographic-guided anterior approach capsular distension and a fluoroscopy-guided posterolateral approach capsular distension. We expected the anterior approach to be better than the posterolateral approach because the rotator interval, a triangular anatomic area in the anterosuperior aspect of the shoulder, which is considered an important component of the...

  1. Anterior capsule staining using 0.025% trypan blue in cataracts without red reflex Uso de azul tripano a 0,025% para corar a cápsula anterior em catarata sem reflexo

    Directory of Open Access Journals (Sweden)

    Eduardo Ferrari Marback

    2001-08-01

    Full Text Available Purpose: To describe the use of anterior capsule staining in cataracts without red reflex using a 0.025% trypan blue solution. Methods: Six eyes of 6 patients with cataracts without red reflex were submitted to phacoemulsification using a direct injection of 0.2 to 0.5 ml of 0.025% trypan blue in the anterior chamber previous to viscoelastic injection. All patients had an ophthalmologic examination prior to surgery, as well as pre and postoperative corneal endothelial cell count. Results: In all cases the capsule became stained with a faint blue color that enabled an adequate visibility of the flap during the continuous curvilinear anterior capsulotomy (CCC. There were no intra-or postoperative complications. The endothelial cell loss varied between 1.8% and 26.6% (mean 12.8%. Conclusion: Staining the anterior capsule with 0.025% trypan blue solution allows a good visibility of the capsular flap and facilitates the confection of CCC in cataracts without red reflex.

  2. Treatment of phimosis with topical steroids and foreskin anatomy

    Directory of Open Access Journals (Sweden)

    Tatiana C. Marques

    2005-08-01

    Full Text Available OBJECTIVES: To correlate topical steroidal treatment of stenosed foreskin with the different degrees of glans exposure and the length of time the ointment is applied. MATERIALS AND METHODS: We studied 95 patients with phimosis, divided according to the degree of foreskin retraction. Group A presented no foreskin retraction, group B presented exposure of only the urethral meatus, group C presented exposure of half of the glans, and group D presented exposure of the glans, which was incomplete because of preputial adherences to the coronal sulcus. Patients were submitted to application of 0.05% betamethasone ointment on the distal aspect of the prepuce twice daily for a minimum of 30 days and a maximum of 4 months. RESULTS: Of 95 patients, 10 (10.52% abandoned the treatment and 15 patients in groups C and D were excluded from the study. Among the remaining 70 patients, only 4 patients (5.7% in group A did not obtain adequate glans exposure after treatment. In group A (38 patients, fully retractable foreskins were obtained in 19 patients (50% after 1 month of treatment. In group B (28 patients, fully retractable foreskins were obtained in 18 patients (64.2% after 1 month. CONCLUSIONS: Treatment was successful in 94.2% of patients, irrespective of the type of foreskin anatomy. The improvement may require several months of treatment. Patients with impossibility of urethral meatus exposure present around 10% treatment failure.

  3. Episodic memory following deep brain stimulation of the ventral anterior limb of the internal capsule and electroconvulsive therapy.

    Science.gov (United States)

    Bergfeld, Isidoor O; Mantione, Mariska; Hoogendoorn, Mechteld L C; Horst, Ferdinand; Notten, Peter; Schuurman, P Richard; Denys, Damiaan

    Electroconvulsive Therapy (ECT) and Deep Brain Stimulation (DBS) are effective treatments for patients with treatment-resistant depression (TRD). However, a common side effect of ECT is autobiographical memory loss (e.g., personal experiences), whereas the impact of DBS on autobiographical memories has never been established. Comparing autobiographical memories following DBS and ECT. In two hospitals in The Netherlands, we interviewed 25 TRD patients treated with DBS of the ventral anterior limb of the internal capsule (vALIC), 14 TRD patients treated with ECT and 22 healthy controls (HC) with the Autobiographical Memory Inventory - Short Form (AMI-SF) in a prospective, longitudinal study between March 2010 and August 2016. Patients treated with DBS were interviewed before surgery, after surgery, and twice during treatment over 122.7 (SD: ±22.2) weeks. Patients treated with ECT were tested before ECT, after six right unilateral (RUL) ECT sessions and twice following ECT over 65.1 (±9.3) weeks. Controls were tested four times over 81.5 (±15.6) weeks. Compared to HC, the AMI-SF score decreased faster in both TRD groups (P ECT group was larger than both the DBS and HC groups. Both ECT and vALIC DBS result in a faster autobiographical memory decline compared to HC. DBS might have a negative impact on autobiographical memories, although less so than ECT. Future work should dissect whether DBS or characteristics of TRD cause this decline. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Y-V plasty of the foreskin as an alternative to circumcision for surgical treatment of phimosis during childhood

    NARCIS (Netherlands)

    Nieuwenhuijs, Jaap L.; Dik, Pieter; Klijn, Aart J.; de Jong, Tom P. V. M.

    2007-01-01

    To evaluate the result of Y-V preputioplasty and to compare this with an earlier technique of prepuce-sparing phimosis treatment. A total of 65 boys were treated surgically for phimosis without removing the foreskin. Indications were the failure of conservative ointment treatment, congenital

  5. Delayed rupture of the extensor hallucis longus and extensor digitorum communis tendons after breaching the anterior capsule with a radiofrequency probe during ankle arthroscopy: a case report.

    Science.gov (United States)

    Tuncer, Serdar; Aksu, Neslihan; Isiklar, Ugur

    2010-01-01

    A 40-year-old man with early arthritis, loose bodies, and anterolateral joint impingement symptoms in his left ankle, which was refractory to noninvasive therapeutic modalities for 1 year, underwent ankle arthroscopy and radiofrequency thermal ablation. The anterior capsule of the ankle joint was breached by the radiofrequency probe while the loose bodies were removed from the anterior recess, exposing the extensor tendons and resulting in a delayed spontaneous rupture of the extensor hallucis longus tendon and extensor tendons to the second and third toes. The extensor hallucis longus tendon was repaired with a semitendinosus tendon graft, and extensor digitorum tendons underwent primary repair. The patient regained full function and was symptom free 1 year after surgery. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Randomized controlled trial for efficacy of capsular distension for adhesive capsulitis: fluoroscopy-guided anterior versus ultrasonography-guided posterolateral approach.

    Science.gov (United States)

    Bae, Jae Hyun; Park, Young Sook; Chang, Hyun Jung; Kim, Min Jung; Park, Kang Young; Jin, Seung Hwan; Lee, Eun Hee

    2014-06-01

    To find the most effective procedure to treat adhesive capsulitis of the shoulder, we evaluated the clinical effects of an ultrasonographic-guided anterior approach capsular distension and a fluoroscopy-guided posterolateral approach capsular distension. We expected the anterior approach to be better than the posterolateral approach because the rotator interval, a triangular anatomic area in the anterosuperior aspect of the shoulder, which is considered an important component of the pathology of adhesive capsulitis. PARTICIPANTS WERE RANDOMLY ASSIGNED TO TWO GROUPS: 27 patients in group A were injected by an anterior approach with 2% lidocaine (5 mL), contrast dye (5 mL), triamcinolone (40 mg), and normal saline (9 mL) under fluoroscopic guidance in the operating room. Twenty-seven patients in group B were injected using a posterolateral approach with 2% lidocaine (5 mL), triamcinolone (40 mg), and normal saline (14 mL) under ultrasonographic guidance. After injection, all patients received physiotherapy four times in the first postoperative week and then two times each week for eight more weeks. Treatment effects were assessed using the shoulder pain and disability index (SPADI), visual numeric scale (VNS), passive range of motion (PROM), hand power (grip and pinch) at baseline and at one week, five and nine weeks after injection. SPADI, VNS, PROM, and hand power improved in one week, five and nine weeks in both groups. Statistically significant differences were not observed in SPADI, VNS, PROM, or hand power between groups. Ultrasonography-guided capsular distension by a posterolateral approach has similar effects to fluoroscopy-guided capsular distension by an anterior approach.

  7. Randomized Controlled Trial for Efficacy of Capsular Distension for Adhesive Capsulitis: Fluoroscopy-Guided Anterior Versus Ultrasonography-Guided Posterolateral Approach

    Science.gov (United States)

    Bae, Jae Hyun; Chang, Hyun Jung; Kim, Min Jung; Park, Kang Young; Jin, Seung Hwan; Lee, Eun Hee

    2014-01-01

    Objective To find the most effective procedure to treat adhesive capsulitis of the shoulder, we evaluated the clinical effects of an ultrasonographic-guided anterior approach capsular distension and a fluoroscopy-guided posterolateral approach capsular distension. We expected the anterior approach to be better than the posterolateral approach because the rotator interval, a triangular anatomic area in the anterosuperior aspect of the shoulder, which is considered an important component of the pathology of adhesive capsulitis. Methods Participants were randomly assigned to two groups: 27 patients in group A were injected by an anterior approach with 2% lidocaine (5 mL), contrast dye (5 mL), triamcinolone (40 mg), and normal saline (9 mL) under fluoroscopic guidance in the operating room. Twenty-seven patients in group B were injected using a posterolateral approach with 2% lidocaine (5 mL), triamcinolone (40 mg), and normal saline (14 mL) under ultrasonographic guidance. After injection, all patients received physiotherapy four times in the first postoperative week and then two times each week for eight more weeks. Treatment effects were assessed using the shoulder pain and disability index (SPADI), visual numeric scale (VNS), passive range of motion (PROM), hand power (grip and pinch) at baseline and at one week, five and nine weeks after injection. Results SPADI, VNS, PROM, and hand power improved in one week, five and nine weeks in both groups. Statistically significant differences were not observed in SPADI, VNS, PROM, or hand power between groups. Conclusion Ultrasonography-guided capsular distension by a posterolateral approach has similar effects to fluoroscopy-guided capsular distension by an anterior approach. PMID:25024960

  8. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  9. Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction.

    Science.gov (United States)

    Kramer, Gregory D; Werner, Liliana; Neuhann, Tobias; Tetz, Manfred; Mamalis, Nick

    2015-09-01

    We describe the case of a patient who had cataract surgery with implantation of the hydrophilic acrylic Tetraflex accommodating intraocular lens (IOL), with subsequent development of capsulorhexis phimosis and in-the-bag IOL subluxation. Contraction of the capsular bag secondary to fibrosis resulted in significant anterior flexing of the lens haptic component. Explantation of the IOL-capsular bag complex was required 7 years after implantation. Histopathologic analysis demonstrated multiple areas of thick anterior subcapsular fibrosis. Pseudoexfoliative material was present throughout the surface of the lens capsule. Intraocular lenses manufactured from hydrophilic acrylic material are highly flexible and may be more susceptible to capsule contraction, even in the absence of predisposing ocular and systemic conditions. This case highlights the importance of developing guidelines regarding patient screening and selection for the appropriate use of accommodating and other highly flexible IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. The Analysis of Intracellular and Intercellular Calcium Signaling in Human Anterior Lens Capsule Epithelial Cells with Regard to Different Types and Stages of the Cataract.

    Directory of Open Access Journals (Sweden)

    Marko Gosak

    Full Text Available In this work we investigated how modifications of the Ca2+ homeostasis in anterior lens epithelial cells (LECs are associated with different types of cataract (cortical or nuclear and how the progression of the cataract (mild or moderate affects the Ca2+ signaling. We systematically analyzed different aspects of intra- and inter-cellular Ca2+ signaling in the human LECs, which are attached to surgically isolated lens capsule (LC, obtained during cataract surgery. We monitored the temporal and spatial changes in intracellular Ca2+ concentration after stimulation with acetylcholine by means of Fura-2 fluorescence captured with an inverted microscope. In our analysis we compared the features of Ca2+ signals in individual cells, synchronized activations, spatio-temporal grouping and the nature of intercellular communication between LECs. The latter was assessed by using the methodologies of the complex network theory. Our results point out that at the level of individual cells there are no significant differences when comparing the features of the signals with regard either to the type or the stage of the cataract. On the other hand, noticeable differences are observed at the multicellular level, despite inter-capsule variability. LCs associated with more developed cataracts were found to exhibit a slower collective response to stimulation, a less pronounced spatio-temporal clustering of LECs with similar signaling characteristics. The reconstructed intercellular networks were found to be sparser and more segregated than in LCs associated with mild cataracts. Moreover, we show that spontaneously active LECs often operate in localized groups with quite well aligned Ca2+ activity. The presence of spontaneous activity was also found to affect the stimulated Ca2+ responses of individual cells. Our findings indicate that the cataract progression entails the impairment of intercellular signaling thereby suggesting the functional importance of altered Ca2

  11. Structural analysis of the phimotic prepuce in patients with failed topical treatment compared with untreated phimosis

    Directory of Open Access Journals (Sweden)

    Luciano Alves Favorito

    2012-12-01

    Full Text Available Objectives To evaluate histological alterations in prepuce of patients with phimosis submitted to topic treatment with betamethasone in association with hyaluronidase. Materials and Methods We studied sixty patients (mean age 4.5, presenting true phimosis and treated with a topical treatment with betamethasone cream (0.2% + hyaluronidase. The parents of seven of these patients opted for circumcision (control group. The other fifty-three patients were submitted to clinical treatment. The samples were stained with Weigert's resorcin-fuchsin (analysis of the elastic fibers and Picro-Sirius Red, for analysis of the collagen. The volumetric density of the elastic fibers was determined by stereological methods. Results Only eight (15% of the fifty-three patients submitted to topical treatment presented failure, being indicated for circumcision (histological analysis. We observed an increase of the collagen type III of the patients submitted to topical treatment. The quantification showed a reduction of the volumetric density of the prepuce's elastic fibers of the patients submitted to the cream treatment, when compared to the control group (p = 0.056. The volumetric density of the elastic fibers of the prepuce at the group not submitted to topical treatment showed an average of 14.60% (11.06 to 21.64%; in the group submitted to the cream treatment, the volumetric density of the elastic fibers of the prepuce showed an average of 10.34% (3.45 to 17.9%. Conclusion The topical treatment of phimosis with betamethasone 0.2% + hyaluronidase had a success rate of 85%. Patients with failure of the topical treatment with steroid had histological alterations in the prepuce.

  12. Fournier's gangrene of the penis in a 12-year-old patient secondary to phimosis.

    Science.gov (United States)

    Ward, Luther; Eisenson, Daniel; Fils, Jean-Louis

    2016-12-01

    We report a case of Fournier's gangrene in a 12-year-old boy from St. Boniface Hospital in Fond-des-Blancs, Haiti. Fournier's gangrene, a fulminant necrotizing fasciitis of the penis and scrotum, is a rare and life-threatening infection that requires hospitalization, broad-spectrum antibiotics, and surgical debridement.1-3 It is usually associated with impaired cellular immunity due to systemic disorders such as diabetes and liver disease.4,5 This patient had none of those risk factors, but had severe, longstanding phimosis, for which circumcision had been recommended many years before. This case illustrates how lack of access to basic surgical care for an easily treatable condition leads to advanced presentation of a severe disease process. [Full article available at http://rimed.org/rimedicaljournal-2016-12.asp].

  13. [Shang Ring circumcision versus conventional circumcision for redundant prepuce or phimosis: a meta analysis].

    Science.gov (United States)

    Xiao, Er-Long; Ding, Hui; Li, Yong-Qian; Wang, Zhi-Ping

    2013-10-01

    To compare the effect and safety of Shang Ring circumcision with those of conventional circumcision in the treatment of redundant prepuce or phimosis. We retrieved the randomized controlled trials on Shang Ring circumcision and conventional circumcision for the treatment of redundant prepuce or phimosis published at home and abroad. Relevant data were selected according to the Cochrane Handbook for Systematic Reviews by two reviewers after quality evaluation of the included trials, and the statistical software RevMan 5.0 was used for meta analysis. Totally 8 randomized controlled trials with 2277 cases were included in this study. Compared with conventional circumcision, Shang Ring circumcision showed a shorter operation time (SMD = -5.82, 95% CI [ -7.39, -4.24], PSMD = -3.28, 95% CI [ -3.47, -3.09], Pinfection (OR = 0.44, 95% CI [0.26, 0.72], P=0.001), lower rate of postoperative bleeding (OR =0.05, 95% CI [0.02, 0.12], PSMD = -3.32, 95% CI [ -3.50, -3.14], PSMD = -3.28, 95% CI [ - 3.47, - 3.00], P<0.00001), but longer wound healing time (OR=1.46, 95% CI [1.03, 1.90], P<0.00001). In comparison with conventional circumcision, Shang Ring circumcision has the advantages of shorter operation time, fewer complications, mild pain, and higher rate of satisfaction with the postoperative penile appearance. However, more high-quality randomized controlled trials with large samples are required to lend further support to our findings.

  14. Outcome of a standardized technique of preputial preservation surgery for phimosis: A single institutional experience

    Directory of Open Access Journals (Sweden)

    Kamalesh Pal

    2014-01-01

    Full Text Available Introduction: Pathological phimosis or preputial stenosis is a distressing problem in children leading to recurrent balanoposthitis, ballooning of prepuce, and rarely back pressure changes in the urinary tract. Circumcision has been the standard of care for such situations, although recently, various alternatives to circumcision have been reported in the literature. Most of these techniques are often complex and are met with poor acceptance. Moreover, besides personal preferences (in Hindus, advantages of preputial preservation is increasingly being realized recently. Materials and Methods: A prospective study was carried out in which a simple standardized technique of preputioplasty (dorsal slit was used in 40 pediatric preputial stenosis cases. The outcome of this procedure including cosmesis and parental satisfaction was evaluated. Results: The average duration of this procedure was from 10 to 25 min with no intraoperative complications. The cosmetic outcome was good in 62.5%, satisfactory in 30%, and poor in 7.5% of cases. All of the boys had retractable prepuce with no functional problems. There was 100% parental satisfaction. None of the patients required a redo procedure or circumcision. Conclusion: A dorsal slit of adequate length i.e.; 1/3 rd the length from the corona to the tip leads to a satisfactory cosmetic outcome in more than 92% of cases. Preputioplasty is a safe and simple alternative to more radical procedure of circumcision.

  15. External Genital Anomaly and Phimosis Prevalence in Male School Children in Sakarya Province

    Directory of Open Access Journals (Sweden)

    Salih Budak

    2014-03-01

    Full Text Available Aim: The goal of the study was to determine external genital anomaly types in children attending primary school (6-15 years old in Sakarya. Material and Method: 1573, 6-15 years old student randomly selected from 8 schools inside the province. The students were examined in an appropriate room in the school, and external genital anomalies were identified and noted. Results: In this study, a total of 106 (6,7 % anomalies were identified in 1573 students. The most common anomalies were phimosis 3,6 % (56 and undescended testis 2,6 % (41. Discussion: This study shows that the ratio of the external genital anomaly that needs to be cured before primary school is high. Socioeconomic differences and environmental factors can affect anomaly prevalence. Health care workers all over the country should be trained regarding the issue. In addition to these, to identify genital anomalies before children start primary school, specific training programs should be prepared for parents.

  16. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  17. opened capsule

    African Journals Online (AJOL)

    The accuracy of the off-label opened capsule dosing method for stavudine is acceptable. There is no need to instruct caregivers to include sediment in the aliquot given to the infant. However, studies that confirm adequate bioavailability and efficacy are needed. In addition, it is important to avoid supplying generic capsules ...

  18. Comparative efficacy and safety of different circumcisions for patients with redundant prepuce or phimosis: A network meta-analysis.

    Science.gov (United States)

    Huang, Chuiguo; Song, Pan; Xu, Changbao; Wang, Ruofan; Wei, Lei; Zhao, Xinghua

    2017-07-01

    Phimosis and redundant prepuce are defined as the inability of the foreskin to be retracted behind the glans penis in uncircumcised males. To synthesize the evidence and provide the hierarchies of different circumcisions for phimosis and redundant prepuce, we performed an overall network meta-analysis (NMA) based on their comparative efficacy and safety. Electronic databases including PubMed, Embase, Wan Fang, VIP, CNKI and CBM database were researched from randomized controlled trials (RCTs) for redundant prepuce or phimosis. We conducted the direct and indirect comparisons by aggregate data drug information system (ADDIS) software. Moreover, consistency models were applied to assess the differences among the male circumcision practices, and the ranks based on probabilities of intervention for the different endpoints were performed. Node-splitting analysis was used to test inconsistency. Eighteen RCTs were included with 6179 participants. Compared with the conventional circumcision(CC), two new styles of circumcisions, the disposable circumcision suture device(DCSD) and Shang Ring circumcision(SRC), provided significantly shorter operation time[DCSD: standardized mean difference (SMD) = -20.60, 95% credible interval(CI) (-23.38, -17.82); SRC: SMD = -19.16, 95%CI (-21.86, -16.52)], shorter wound healing time [DCSD:SMD = -4.19, 95%CI (-8.24,-0.04); SRC: SMD = 4.55, 95%CI (1.62, 7.57); ] and better postoperative penile appearance [DCSD: odds ratios odds ratios (OR) = 11.42, 95%CI (3.60, 37.68); SRC: OR = 3.85,95%CI (1.29, 12.79)]. Additionally, DCSD showed a lower adverse events rate than other two treatments. However, no significant difference was shown in all surgeries for 24 h postoperative pain score. Node-splitting analysis showed that no significant inconsistency was existed (P > 0.05). Based on the results of NMA, DCSD may be a most effective and safest choice for phimosis and redundant prepuce. DCSD has the advantages of a shorter operation

  19. [Could phimosis have been the cause of sexual difficulties and delayed fertility of Louis XVI (1754-1793)?].

    Science.gov (United States)

    Androutsos, Georges

    2002-02-01

    The great majority of historians agree that the marriage of Louis XVI and Marie-Antoinette was only consumated seven years after the official ceremony. This delay could have been due to a genital malformation (phimosis) of Louis XVI, a strict religious education, a traumatic childhood and the young age of the two spouses, factors that may have inhibited their sexuality. In this article, the authors try to determine whether Louis XVI was able to overcome his sexual difficulties following an operation (circumcision) or as a result of spontaneous cure.

  20. Phimosis in male dromedary camels: Clinical findings and changes in the hemogram, nitric oxide metabolites, and testosterone concentrations.

    Science.gov (United States)

    Ali, Ahmed; Derar, Derar; Al-Sobyil, Fahd A; Zeitoun, Moustafa M; Hassanein, Khaled M A; Al-Howas, Abdella

    2016-06-01

    The objectives of this study were to elucidate the clinical findings in male dromedary camels with phimosis (PHI, n = 43) and to investigate the association of this syndrome with the hemogram, nitric oxide metabolites (NOMs), and testosterone concentrations. History and signalment were obtained, and a breeding soundness examination was performed. The penis was exteriorized after administration of a pudendal nerve block. Abnormal masses obtained from the prepuce and penis were prepared for histopathology. Blood samples for hemogram assessment were taken from the diseased animals and from 10 healthy control males. Total nitrates/nitrites were determined in sera using the Griess assay. Testosterone was estimated in sera using ELISA. Phimosis associated with detectable pathologic lesions, mainly including ulcerative posthitis and lacerated glans penis, was present in 34 (79.1%) of the 43 cases (PHI-P), whereas the remaining nine (20.9%) of the 43 cases had no noticeable lesions (PHI-N). The PHI-P group showed higher leukocyte counts (P = 0.001), especially neutrophils (P = 0.0001), and greater NOM concentrations (P = 0.002) than the PHI-N and control groups. However, testosterone concentrations did not differ among groups. In conclusion, PHI in the male dromedary camels was mainly associated with ulcerative posthitis and laceration of the glans penis. The presence of pathologic lesions in cases with PHI was associated with leukocytosis, neutrophilia, and high NOM concentrations. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Capsule endoscopy

    DEFF Research Database (Denmark)

    Skovsen, Anders Peter; Burcharth, Jakob; Burgdorf, Stefan Kobbelgaard

    2013-01-01

    with ultrasound, MRI, and subsequently a capsule endoscopy. Six months later, the patient presented, and an abdominal CT-scan showed mechanical small bowel obstruction with suspicion of metallic foreign body and perforation. Laparotomy showed perforation, stenosis, and foreign body, approximately 5 cm from...

  2. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  3. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  4. Adhesive Capsulitis of the Shoulder Joint: Value of Glenohumeral Distance on Magnetic Resonance Arthrography.

    Science.gov (United States)

    Lee, Kyu Hong; Park, Hee Jin; Lee, So Yeon; Youn, In Young; Kim, Eugene; Park, Jai Hyung; Park, Se Jin

    2017-01-01

    To evaluate the usefulness of glenohumeral distance (GHD) on axial images of magnetic resonance (MR) arthrography for diagnosis of adhesive capsulitis and to compare this finding with previously reported classic MR arthrographic findings of adhesive capsulitis. Our study was approved by the institutional ethical review board of our institute. We evaluated 41 patients (M-F, 35:6; mean age, 46 years; adhesive capsulitis, 21; no adhesive capsulitis, 20) who underwent MR arthrography. Two radiologists measured GHD, width of the axillary recess, and capsular thickness in consensus. The GHD was measured from the subchondral bone of the glenoid fossa to the subchondral bone of the humeral head at the level of the midline of the humeral head. Glenohumeral distance (anterior, middle, posterior, and mean), width of the axillary recess, and capsular thickness (anterior, posterior, and mean) were compared in the adhesive capsulitis and no adhesive capsulitis groups using the Mann-Whitney U test. The mean GHD of the no adhesive capsulitis group was longer than that of the adhesive capsulitis group. The length differences were statistically significant (P adhesive capsulitis group was significantly wider than that of the adhesive capsulitis group (P adhesive capsulitis group was significantly thinner than that in the adhesive capsulitis group (P = 0.001). A decreased GHD on MR arthrography can be another useful feature to diagnose adhesive capsulitis in addition to previously presented radiologic features such as capsular thickening and reduced axillary recess capacity.

  5. Polydopamine-coated capsules

    Energy Technology Data Exchange (ETDEWEB)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen; Baginska, Marta B.

    2018-04-17

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  6. Egg capsules of the dusky catshark Bythaelurus canescens (Carcharhiniformes, Scyliorhinidae) from the south-eastern Pacific Ocean.

    Science.gov (United States)

    Concha, F; Bustamante, C; Oddone, M C; Hernández, S; Lamilla, J

    2010-09-01

    The external morphology of the egg capsule of Bythaelurus canescens and its fixation to the substratum are described. Bythaelurus canescens egg capsules are typically vase-shaped, dorso-ventrally flattened, pale yellow in colour when fresh and covered by 12-15 longitudinal ridges. The anterior border of the capsule is straight, whereas the posterior border is semicircular. Two horns bearing long, coiled tendrils arise from the anterior and posterior ends of the capsule. The presence of longitudinal ridges and long coiled tendrils at both anterior and posterior ends of the capsule readily distinguish these egg capsules from those of other chondrichthyans occurring in the south-east Pacific Ocean. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  7. Wireless capsule endoscopy

    Science.gov (United States)

    Iddan, Gavriel; Meron, Gavriel; Glukhovsky, Arkady; Swain, Paul

    2000-05-01

    We have developed a new type of endoscopy, which for the first time allows painless endoscopic imaging of the whole of the small bowel. This procedure involves a wireless capsule endoscope and we describe here its successful testing in humans.

  8. The mechanical properties of the human hip capsule ligaments.

    Science.gov (United States)

    Hewitt, John D; Glisson, Richard R; Guilak, Farshid; Vail, T Parker

    2002-01-01

    The human hip capsule is adapted to facilitate upright posture, joint stability, and ambulation, yet it routinely is excised in hip surgery without a full understanding of its mechanical contributions. The objective of this study was to provide information about the mechanical properties of the ligaments that form the hip capsule. Cadaver bone-ligament-bone specimens of the iliofemoral, ischiofemoral, and femoral arcuate ligaments were tested to failure in tension. The hip capsule was found to be an inhomogeneous structure and should be recognized as being composed of discrete constituent ligaments. The anterior ligaments, consisting of the 2 arms of the iliofemoral ligament, were much stronger than the posterior ischiofemoral ligament, withstanding greater force at failure and exhibiting greater stiffness. Knowledge of the anatomy and mechanical properties of the capsule may help the hip surgeon choose an appropriate surgical approach or repair strategy.

  9. Non-contact optical measurement of lens capsule thickness during simulated accommodation

    Science.gov (United States)

    Ziebarth, Noel; Manns, Fabrice; Acosta, Ana-Carolina; Parel, Jean-Marie

    2005-04-01

    Purpose: To non-invasively measure the thickness of the anterior and posterior lens capsule, and to determine if it significantly changes during accommodation. Methods: Anterior and posterior capsule thickness was measured on post-mortem lenses using a non-contact optical system using a focus-detection technique. The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused on the tissue surface using an aspheric lens (NA=0.68) mounted on a translation stage with a motorized actuator. Light reflected from the sample surface is collected by the fiber coupler and sent to a photoreceiver connected to a computer-controlled data acquisition system. Optical intensity peaks are detected when the aspheric lens is focused on the capsule boundaries. The capsule thickness is equal to the distance traveled between two peaks multiplied by the capsule refractive index. Anterior and posterior lens capsule thickness measurements were performed on 18 cynomolgus (age average: 6+/-1 years, range: 4-7 years) eyes, 1 rhesus (age: 2 years) eye, and 12 human (age average: 65+/-16, range: 47-92) eyes during simulated accommodation. The mounted sample was placed under the focusing objective of the optical system so that the light was incident on the center pole. Measurements were taken of the anterior lens capsule in the unstretched and the stretched 5mm states. The lens was flipped, and the same procedure was performed for the posterior lens capsule. Results: The precision of the optical system was determined to be +/-0.5um. The resolution is 4um and the sensitivity is 52dB. The human anterior lens capsule thickness was 6.0+/-1.2um unstretched and 4.9+/-0.9um stretched (p=0.008). The human posterior lens capsule was 5.7+/-1.2um unstretched and 5.7+/-1.4um stretched (p=0.974). The monkey anterior lens capsule thickness was 5.9+/-1.9um unstretched and 4.8+/-1.0um stretched (p=0.002). The monkey posterior lens capsule was 5

  10. Advances in Capsule Endoscopy

    Science.gov (United States)

    Scott, Ryan

    2015-01-01

    Wireless video capsule endoscopy (VCE) is a minimally invasive technology that has revolutionized the approach to small intestinal disease investigation and management. Designed primarily to provide diagnostic imaging of the small intestine, VCE is used predominantly for obscure gastrointestinal bleeding and suspected Crohn’s disease; however, numerous other indications have been established, including the assessment of celiac disease, investigation of small bowel tumors, and surveillance of hereditary polyposis syndromes. Since the introduction of small bowel VCE in 2000, more than 1600 articles have been published describing the evolution of this technology. The main adverse outcome is capsule retention, which can potentially be avoided by careful patient selection or by using a patency capsule. Despite the numerous advances in the past 15 years, limitations such as incomplete VCE studies, missed lesions, and time-consuming reporting remain. The inability to control capsule movement for the application of targeted therapy or the acquisition of tissue for histologic analysis remains among the greatest challenges in the further development of capsule technology. This article outlines the recent technological and clinical advances in VCE and the future directions of research in this field. PMID:27482183

  11. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  12. Hollow Microporous Organic Capsules

    Science.gov (United States)

    Li, Buyi; Yang, Xinjia; Xia, Lingling; Majeed, Muhammad Irfan; Tan, Bien

    2013-01-01

    Fabrication of hollow microporous organic capsules (HMOCs) could be very useful because of their hollow and porous morphology, which combines the advantages of both microporous organic polymers and non-porous nanocapsules. They can be used as storage materials or reaction chambers while supplying the necessary path for the design of controlled uptake/release systems. Herein, the synthesis of HMOCs with high surface area through facile emulsion polymerization and hypercrosslinking reactions, is described. Due to their tailored porous structure, these capsules possessed high drug loading efficiency, zero-order drug release kinetics and are also demonstrated to be used as nanoscale reactors for the prepareation of nanoparticles (NPs) without any external stabilizer. Moreover, owing to their intrinsic biocompatibility and fluorescence, these capsules exhibit promising prospect for biomedical applications. PMID:23820511

  13. The posterior segment of the temporomandibular joint capsule and its anatomic relationship.

    Science.gov (United States)

    Mérida-Velasco, J Ramón; Rodríguez, J Francisco; de la Cuadra, Crótida; Peces, M Dolores; Mérida, J Antonio; Sánchez, Indalecio

    2007-01-01

    The aim of this work was to clarify the arrangement of the posterior segment of the temporomandibular joint capsule and its pertinent relationships. The temporomandibular region was dissected bilaterally in 20 adult cadavers. Natural stained latex was injected into 16 cadavers through the external carotid artery to facilitate the dissection of the arterial vessels. The posterior segment of the joint capsule is made up of the so-called "bilaminar zone" of the articular disc. The upper internal portion of the posterior segment of the capsule was reinforced by the discomalleolar ligament. The retroarticular space was filled with loose connective tissue and the anterior branches of the anterior tympanic artery were distributed throughout the posterior segment of the joint capsule. The posterior segment of the temporomandibular joint capsule corresponds to the bilaminar zone of the articular disc. The structures of the retroarticular space are extracapsular.

  14. Gelatin capsule in stomach (image)

    Science.gov (United States)

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  15. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  16. Management of adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Stupay KL

    2015-08-01

    Full Text Available Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive criteria for diagnosis make evaluating treatment modalities difficult. Many treatment methods have been reported, most with some success, but few have been proved to alter the natural course of this disease. Most afflicted patients will achieve acceptable shoulder function without surgery. Those who remain debilitated after 8–12 months are reasonable candidates for invasive treatments. Here, the various treatment methods and the data to support their use are reviewed. Keywords: frozen shoulder, stiff shoulder, periarthritis, painful shoulder 

  17. Atraumatic Anterior Dislocation of the Hip Joint

    Directory of Open Access Journals (Sweden)

    Tadahiko Ohtsuru

    2015-01-01

    Full Text Available Dislocation of the hip joint in adults is usually caused by high-energy trauma such as road traffic accidents or falls from heights. Posterior dislocation is observed in most cases. However, atraumatic anterior dislocation of the hip joint is extremely rare. We present a case of atraumatic anterior dislocation of the hip joint that was induced by an activity of daily living. The possible causes of this dislocation were anterior capsule insufficiency due to developmental dysplasia of the hip, posterior pelvic tilt following thoracolumbar kyphosis due to vertebral fracture, and acetabular anterior coverage changes by postural factor. Acetabular anterior coverage changes in the sagittal plane were measured using a tomosynthesis imaging system. This system was useful for elucidation of the dislocation mechanism in the present case.

  18. Adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Neviaser, Andrew S; Neviaser, Robert J

    2011-09-01

    Adhesive capsulitis is characterized by painful, gradual loss of active and passive shoulder motion resulting from fibrosis and contracture of the joint capsule. Other shoulder pathology can produce a similar clinical picture, however, and must be considered. Management is based on the underlying cause of pain and stiffness, and determination of the etiology is essential. Subtle clues in the history and physical examination can help differentiate adhesive capsulitis from other conditions that cause a stiff, painful shoulder. The natural history of adhesive capsulitis is a matter of controversy. Management of true capsular restriction of motion (ie, true adhesive capsulitis) begins with gentle, progressive stretching exercises. Most patients improve with nonsurgical treatment. Indications for surgery should be individualized. Failure to obtain symptomatic improvement and continued functional disability following ≥6 months of physical therapy is a general guideline for surgical intervention. Diligent postoperative therapy to maintain motion is required to minimize recurrence of adhesive capsulitis.

  19. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Fernandes, Marcos Rassi

    2014-01-01

    to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66), predominantly female (90%), six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40%) and six secondary (60%). the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (padhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  20. The effect of myofibroblasts and corticosteroid injections in adhesive capsulitis.

    Science.gov (United States)

    Hettrich, Carolyn M; DiCarlo, Edward F; Faryniarz, Deborah; Vadasdi, Katherine B; Williams, Riley; Hannafin, Jo A

    2016-08-01

    Adhesive capsulitis is a condition that results in restricted glenohumeral motion. Fibroblasts have been implicated in the disease process; however, their role as a contractile element in the development of fibrosis and capsular contracture is not well understood. We hypothesized (1) that myofibroblast prevalence in capsular biopsy specimens from patients with adhesive capsulitis would be increased compared with controls and (2) that patients treated with an intra-articular injection of corticosteroid would have fewer myofibroblasts. The study prospectively enrolled 20 consecutive patients with adhesive capsulitis scheduled for capsular release and matched controls. Tissue samples were collected from the posterior and anterior capsule for histomorphologic and immunohistologic analyses. Identical sectioning and preparation was performed in 14 additional adhesive capsulitis specimens from patients who had not received corticosteroid injections. Patients with adhesive capsulitis not treated with preoperative corticosteroid demonstrated more histologic evidence of fibromatosis, synovial hyperplasia, and an increase in positive staining for α-smooth muscle actin than patients who had received intra-articular injections of steroid. No specimens obtained from control patients demonstrated positive staining for α-smooth muscle actin. There was a higher prevalence of myofibroblast staining in patients with adhesive capsulitis, implicating activation of the myofibroblast in the pathophysiology of capsular contracture. Intra-articular steroid injection decreases the presence and amount of fibromatosis, vascular hyperplasia, fibrosis, and the presence of fibroblasts staining for α-smooth muscle actin. This supports the use of steroid injections to alter the disease process by decreasing the pathologic changes found in the capsular tissue. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Wireless capsule endo bronchoscopy

    Directory of Open Access Journals (Sweden)

    Baratz DM

    2014-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Case Presentation History of Present Illness A 67 year-old man presents 10 days after swallowing a capsule endoscopy camera that was never retrieved. The wireless capsule was swallowed asymptomatically for evaluation of heme positive stools after negative upper and lower endoscopies. Patient noted that the evening after swallowing the camera he developed mild shortness of breath and cough. The cough and shortness of breath were persistent and worsened while lying down and when moving positions. He denied prior issues with swallowing or aspiration. Review of Systems Negative other than what is noted above. PMH, SH, and FH Past medical history: coronary artery disease, peripheral vascular disease, hyperlipidemia Surgical history: femoral-popliteal bypass, previous shoulder and back surgery Social history: 1 pack/day of cigarettes for 50 years, prior alcohol usage but not current, no illicit drugs Family history: no pulmonary diseases Physical Exam Vital signs: temperature 36.7º C, heart rate 86 beats per minute ...

  2. Developmental anatomy in the zonular connection with lens capsule in macaque eye.

    Science.gov (United States)

    Hiraoka, Mari; Kuroda, Teiko; Inoue, Kenichi; Senoo, Haruki; Takada, Masahiko

    2013-05-01

    Morphological analyses of zonule conjugated with lens capsule were performed on the developmental change in eyes from the age of fetus to 7 years old of the rhesus macaques (Macaca fuscata). The zonule was filamentous network in late fetus. After birth, the zonular microfibrils originated from the nonpigmented epithelium of the ciliary process. On the extending path toward the lens capsule through the chamber, microfibril assembled with neighbor fibril and also cohered with one another forming bundle. With growth, these bundles bifurcated into anterior and posterior groups on the equatorial region of capsule. The developmental distribution of bundles in the capsule was characteristic on anterior group, that is, bifurcation into radial and circumferential extension. On the other hand, the posterior bundle undivided but radially extended within short distance from the equator. In the process of fixating with capsule, bundles untangled into fibrils and penetrated circumferentially into the superficial layer and radially into deep apical layer of the capsule. Zonule was composed fibrillin 1 microfibrils and on the extending path toward the lens capsule through the chamber, microfibril self-assembled with neighbored fibril in composition of fascicle and also cohered with one another forming bundle. Each bundle had alternating pale and dense horizontal bands in the intracapsular extension and the stripe pattern changed in flaccid or extensive tension of zonule between capsule and process. Zonular fibril intermingled with collagen fibril of capsule with interlacing molecule of laminin. At the base of ciliary muscle, elastin-positive connective tissue intercalated circumferentially between ciliary processes. The developmental changes of the intralamellar distribution and extension of zonule with striped pattern informed the functional role upon the elasticity in coordination with the lens capsule micromolecules. Copyright © 2013 Wiley Periodicals, Inc.

  3. Development of capsule assembling apparatus

    International Nuclear Information System (INIS)

    Tayama, Yoshinobu; Kanazawa, Yoshiharu; Sozawa, Shizuo; Kawamata, Kazuo; Shizuoka, Yoshihiro; Onizawa, Satoshi; Nakagawa, Tetsuya

    2012-01-01

    The service of JMTR hot laboratory, associated with the Japan Materials Testing Reactor, was started on 1971 to examine specimens irradiated mainly in the JMTR. A wide variety of post irradiation examinations for research and development of nuclear fuels and materials are available in the JMTR hot laboratory. This laboratory has an advantage that its hot cell is connected with JMTR by a canal directly, and it is easy to transport irradiated capsule and specimens. New power ramping test for the high burn-up fuels by using the JMTR has been planed. The power ramping test using a boiling water capsule facility needs a re-capsuling of fuel rods for re-irradiation, and a modification of the facility up to about 100 GWD/t were necessary. This report introduces the new handling techniques and capsule assembling apparatus for the boiling water capsule facility. (author)

  4. Quantitative measurements in capsule endoscopy.

    Science.gov (United States)

    Keuchel, M; Kurniawan, N; Baltes, P; Bandorski, D; Koulaouzidis, A

    2015-10-01

    This review summarizes several approaches for quantitative measurement in capsule endoscopy. Video capsule endoscopy (VCE) typically provides wireless imaging of small bowel. Currently, a variety of quantitative measurements are implemented in commercially available hardware/software. The majority is proprietary and hence undisclosed algorithms. Measurement of amount of luminal contamination allows calculating scores from whole VCE studies. Other scores express the severity of small bowel lesions in Crohn׳s disease or the degree of villous atrophy in celiac disease. Image processing with numerous algorithms of textural and color feature extraction is further in the research focuses for automated image analysis. These tools aim to select single images with relevant lesions as blood, ulcers, polyps and tumors or to omit images showing only luminal contamination. Analysis of motility pattern, size measurement and determination of capsule localization are additional topics. Non-visual wireless capsules transmitting data acquired with specific sensors from the gastrointestinal (GI) tract are available for clinical routine. This includes pH measurement in the esophagus for the diagnosis of acid gastro-esophageal reflux. A wireless motility capsule provides GI motility analysis on the basis of pH, pressure, and temperature measurement. Electromagnetically tracking of another motility capsule allows visualization of motility. However, measurement of substances by GI capsules is of great interest but still at an early stage of development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Anterior shoulder capsular tears in professional baseball players.

    Science.gov (United States)

    Gulotta, Lawrence V; Lobatto, Daniel; Delos, Demetris; Coleman, Struan H; Altchek, David W

    2014-08-01

    Tearing of the anterior capsule of the shoulder is a rare but debilitating injury for throwing athletes. However, there is very little in the literature to guide its diagnosis and treatment. In this case series, we outline our experience with anterior capsular tears of the shoulder in professional baseball players. Five professional baseball players were diagnosed with midsubstance tears of their anterior capsule. A trial of rest and rehabilitation failed in all patients, and they eventually underwent surgery. These patients were retrospectively reviewed. The presenting symptoms and findings were documented, and outcomes were assessed by the player's ability to return to play. The mean age was 33.5 years (range, 31-37 years), and all patients presented with anterior shoulder pain and the inability to throw. No patient had an acute traumatic injury. Magnetic resonance imaging provided the correct diagnosis in 4 patients, and the diagnosis was made with diagnostic arthroscopy in the fifth. Three underwent arthroscopic repair, and 2 underwent open repair of the anterior capsule. Of the 5 players, 4 (80%) returned to their preinjury level by a mean of 13.3 months (range, 8-18 months). Anterior capsular tears can occur in older throwing athletes. Surgical repair, whether arthroscopic or open, can yield good results in most patients. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  7. Capsulitis of the Second Toe

    Science.gov (United States)

    ... arch that is structurally unstable and a tight calf muscle. Symptoms Because capsulitis of the second toe is ... may be prescribed for patients who have tight calf muscles. Shoe modifications. Supportive shoes with stiff soles are ...

  8. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Yamaura, Takayuki; Nagao, Yoshiharu

    2013-01-01

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  9. MRI diagnosis of reverse and separation of meniscus articular capsule

    International Nuclear Information System (INIS)

    Tang Xiaofeng; Zhou Chengtao; Mu Renqi; Zhang Guanghui; Xu Yongzhong

    2005-01-01

    Objective: To explore the MR imaging of reverse and separation of meniscal articular capsule. Methods: MR imaging of reverse and separation of meniscus articular capsule confirmed by surgery and arthroscope were analyzed retrospectively in 8 cases. Results: The 'Butterfly knot sign' disappeared and was replaced with fluid signal on the sagittal slice of meniscal body in 8 cases. Part of back angle remained in 3 cases. 'Double anterior cruciate ligament sign' was showed on one side of middle sagittal slice in 7 cases. 'Reverse meniscus sign' was revealed in intercondylar fossa on the coronary view in 8 cases. Abnormal high signal was showed in the injured meniscus in 6 cases. Abnormal high signal was detected in the opposite meniscus in 5 cases. Conclusion: The MR findings of reverse and separation of meniscus articular capsule include disappearance of 'butterfly knot sign', appearance of 'reverse meniscus sign' and 'double anterior cruciate ligament sign'. The diagnosis would be established if the former 2 signs were present or all the 3 signs were present simultaneously. (authors)

  10. Adhesive capsulitis: a review.

    Science.gov (United States)

    Ewald, Anthony

    2011-02-15

    Adhesive capsulitis is a common, yet poorly understood, condition causing pain and loss of range of motion in the shoulder. It can occur in isolation or concomitantly with other shoulder conditions (e.g., rotator cuff tendinopathy, bursitis) or diabetes mellitus. It is often self-limited, but can persist for years and may never fully resolve. The diagnosis is usually clinical, although imaging can help rule out other conditions. The differential diagnosis includes acromioclavicular arthropathy, autoimmune disease (e.g., systemic lupus erythematosus, rheumatoid arthritis), biceps tendinopathy, glenohumeral osteoarthritis, neoplasm, rotator cuff tendinopathy or tear (with or without impingement), and subacromial and subdeltoid bursitis. Several treatment options are commonly used, but few have high-level evidence to support them. Because the condition is often self-limited, observation and reassurance may be considered; however, this may not be acceptable to many patients because of the painful and debilitating nature of the condition. Nonsurgical treatments include analgesics (e.g., acetaminophen, nonsteroidal anti-inflammatory drugs), oral prednisone, and intra-articular corticosteroid injections. Home exercise regimens and physical therapy are often prescribed. Surgical treatments include manipulation of the joint under anesthesia and capsular release.

  11. White matter alterations in the internal capsule and psychomotor impairment in melancholic depression.

    Science.gov (United States)

    Hyett, Matthew P; Perry, Alistair; Breakspear, Michael; Wen, Wei; Parker, Gordon B

    2018-01-01

    Emerging evidence suggests that structural brain abnormalities may play a role in the pathophysiology of melancholic depression. We set out to test whether diffusion-derived estimates of white matter structure were disrupted in melancholia in regions underpinning psychomotor function. We hypothesized that those with melancholia (and evidencing impaired psychomotor function) would show disrupted white matter organization in internal capsule subdivisions. Diffusion magnetic resonance imaging (dMRI) data were acquired from 22 melancholic depressed, 23 non-melancholic depressed, and 29 healthy control participants. Voxel-wise fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) values were derived for anterior, posterior, and retrolenticular limbs of the internal capsule and compared between groups. Neuropsychological (reaction time) and psychomotor functioning were assessed and correlated against FA. Fractional anisotropy was distinctly increased, whilst RD was decreased, in the right anterior internal capsule in those with melancholia, compared to controls. The right anterior limb of the internal capsule correlated with clinical ratings of psychomotor disturbance, and reduced psychomotor speed was associated with increased FA values in the right retrolenticular limb in those with melancholia. Our findings highlight a distinct disturbance in the local white matter arrangement in specific regions of the internal capsule in melancholia, which in turn is associated with psychomotor dysfunction. This study clarifies the contribution of structural brain integrity to the phenomenology of melancholia, and may assist future efforts seeking to integrate neurobiological markers into depression subtyping.

  12. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Marcos Rassi Fernandes

    Full Text Available OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66, predominantly female (90%, six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40% and six secondary (60%. RESULTS: the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (p<0.001. By the Constant Score (range of motion, there was an increase of 13.8 (average pre to 32 points (average post. CONCLUSION: the arthroscopic treatment proved effective in refractory adhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  13. Biomechanics of the Hip Capsule and Capsule Management Strategies in Hip Arthroscopy.

    Science.gov (United States)

    Nepple, Jeffrey J; Smith, Matthew V

    2015-12-01

    Recent advances in our understanding of the function of the hip capsule have clarified its importance to normal hip function and kinematics. The iliofemoral ligament is the primary stabilizing structure for controlling anterior translation and external rotation of the hip, and is violated by the arthroscopic interportal capsulotomy. Microinstability of the hip occurring after surgical trauma remains a poorly defined clinical entity. In certain at-risk populations, capsular repair should be considered as part of an arthroscopic hip procedure to achieve optimal outcomes and avoid iatrogenic instability (dislocation or microinstability). Despite a lack of conclusive evidence-based indications, we recommend capsular repair in the settings of borderline hip dysplasia (or dysplastic variants such as increased femoral anteversion), hip hypermobility, connective tissue disorders, and traumatic or atraumatic instability. With careful attention to arthroscopic capsular management, adequate exposure can be achieved and reproducibly allow for an effective capsular repair when indicated.

  14. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  15. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  16. Stress Analysis of Cyrano Capsule Hanger

    International Nuclear Information System (INIS)

    Hasibuan, Djaruddin

    2000-01-01

    Base on the requirement criteria on nuclear installation, and to complete the document of the cyrano capsule facility the analysis of the cyrano capsule hanger has been done. The cyrano capsule hanger by the overhang installation on the main support of fixed bridge is a main support of whole of the cyrano capsule and frame. By using W 4 x 13 shave as main hanger of cyrano capsule, the maximum allowable stress was found to be bigger than the actual stress. From the final analysis it can be concluded that the hanger of the cyrano capsule is in safe condition

  17. Endurance test for DUPIC capsule

    International Nuclear Information System (INIS)

    Chung, Heung June; Bae, K. K.; Lee, C. Y.; Park, J. M.; Ryu, J. S.

    1999-07-01

    This report presents the pressure drop, vibration and endurance test results for mini-plate fuel rig which were designed fabricately by KAERI. From the pressure drop test results, it is noted that the flow rate across the capsule corresponding to the pressure drop of 200 kPa is measured to be about 9.632 kg/sec. Vibration frequency for the capsule ranges from 14 to 18.5 Hz. RMS (Root Mean Square) displacement for the fuel rig is less than 14 μm, and the maximum displacement is less than 54 μm. Based on the endurance test results, the appreciable fretting wear for the DUPIC capsule was not detected. Oxidation on the support tube is observed, also tiny trace of wear between contact points observed. (author). 4 refs., 10 tabs., 45 figs

  18. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  19. Osmotic buckling of spherical capsules.

    Science.gov (United States)

    Knoche, Sebastian; Kierfeld, Jan

    2014-11-07

    We study the buckling of elastic spherical shells under osmotic pressure with the osmolyte concentration of the exterior solution as a control parameter. We compare our results for the bifurcation behavior with results for buckling under mechanical pressure control, that is, with an empty capsule interior. We find striking differences for the buckling states between osmotic and mechanical buckling. Mechanical pressure control always leads to fully collapsed states with opposite sides in contact, whereas uncollapsed states with a single finite dimple are generic for osmotic pressure control. For sufficiently large interior osmolyte concentrations, osmotic pressure control is qualitatively similar to buckling under volume control with the volume prescribed by the osmolyte concentrations inside and outside the shell. We present a quantitative theory which also captures the influence of shell elasticity on the relationship between osmotic pressure and volume. These findings are relevant for the control of buckled shapes in applications. We show how the osmolyte concentration can be used to control the volume of buckled shells. An accurate analytical formula is derived for the relationship between the osmotic pressure, the elastic moduli and the volume of buckled capsules. This also allows use of elastic capsules as osmotic pressure sensors or deduction of elastic properties and the internal osmolyte concentration from shape changes in response to osmotic pressure changes. We apply our findings to published experimental data on polyelectrolyte capsules.

  20. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  1. Sensor capsule for diagnosis of gastric disorders

    Science.gov (United States)

    Holen, J. T.

    1972-01-01

    Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

  2. Anterior Horn Cell Diseases

    Directory of Open Access Journals (Sweden)

    Merve Firinciogullari

    2016-09-01

    Full Text Available The anterior horn cells control all voluntary movement. Motor activity, respiratory, speech, and swallowing functions are dependent upon signals from the anterior horn cells. Diseases that damage the anterior horn cells, therefore, have a profound impact. Symptoms of anterior horn cell loss (weakness, falling, choking lead patients to seek medical attention. In this article, anterior horn diseases were reviewed, diagnostic criteria and management were discussed in detail. [Archives Medical Review Journal 2016; 25(3.000: 269-303

  3. Probing cell internalisation mechanics with polymer capsules.

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Ping, Yuan; Suma, Tomoya; Cavalieri, Francesca; Besford, Quinn A; Chen, George; Braunger, Julia A; Caruso, Frank

    2016-10-06

    We report polymer capsule-based probes for quantifying the pressure exerted by cells during capsule internalisation (P in ). Poly(methacrylic acid) (PMA) capsules with tuneable mechanical properties were fabricated through layer-by-layer assembly. The P in was quantified by correlating the cell-induced deformation with the ex situ osmotically induced deformation of the polymer capsules. Ultimately, we found that human monocyte-derived macrophage THP-1 cells exerted up to approximately 360 kPa on the capsules during internalisation.

  4. DIABETES AND SHOULDER ADHESIVE CAPSULITIS

    OpenAIRE

    J. Mohanakrishnan; Bhanumathy Mohanakrishnan

    2016-01-01

    Background: Adhesive capsulitis (AC) of shoulder is a common condition encountered by physical therapists in their routine outpatient care services; AC of shoulder is as by itself being a self limiting disorder lasts from months to years causing pain and discomfort to the patients. The condition is commonly associated with Diabetes mellitus or other co morbidities. The incidence of AC is high among diabetic individuals and it becomes mandatory on the part of physical therapists and other heal...

  5. Contraindications for video capsule endoscopy

    OpenAIRE

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn?s dise...

  6. Anterior capsulotomy with an ultrashort-pulse laser.

    Science.gov (United States)

    Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith

    2011-05-01

    To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Anterior capsular staining with trypan blue for capsulorhexis in mature and hypermature cataracts. A preliminary study

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2001-01-01

    Full Text Available Purpose: To study the efficacy and safety of 0.1% Trypan Blue dye to stain the anterior capsule for capsulorhexis in mature and hypermature cataracts. Methods: This preliminary study included 25 eyes of 25 patients with a unilateral mature or hypermature cataract, including one case of traumatic mature cataract. In all these cases 0.2ml of 0.1% trypan blue dye was used to stain the anterior capsule. The efficacy and safety of the dye was evaluated on the basis of intraoperative and postoperative observations. Results: In all 25 eyes the capsulorhexis was completed. There was peripheral extension of the capsulorhexis in the eye with traumatic cataract and the stained edge of the anterior capsule helped identification and redirection of the capsulorhexis. Successful phacoemulsification with intraocular lens implantation was performed in all eyes. Adverse reactions related to the dye such as raised intraocular pressure, anterior chamber inflammation and endothelial damage were not observed in the immediate postoperative period or at the end of mean follow-up of 3 months. Conclusion: Trypan blue dye staining of the anterior capsule appears to be a very useful and safe technique that simplifies capsulorhexis in mature and hypermature cataracts.

  8. Capsule Endoscopy: A Single Centre Experience with the First 226 Capsules

    Directory of Open Access Journals (Sweden)

    R Enns

    2004-01-01

    Full Text Available BACKGROUND: Capsule endoscopy (CE refers to a novel diagnostic method of imaging the gastrointestinal tract using a wireless capsule that transmits images to a data recorder while the device traverses the small intestine.

  9. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    Haney, T.A.; Wedeking, P.W.; Morcos, N.A.

    1981-01-01

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  10. Challenges and Future of Wireless Capsule Endoscopy.

    Science.gov (United States)

    Saurin, Jean-Christophe; Beneche, Nicolas; Chambon, Christine; Pioche, Mathieu

    2016-01-01

    In 2015, capsule endoscopy was introduced as the main investigation method for small bowel mucosal diseases, and its role in colonic diseases has been gradually revealed. Future challenges for capsule endoscopy, besides improvements of image quality and visualization of each part of the small bowel and colonic mucosa, include the development of gastric capsules, the capacity to perform histological examination of the mucosa, and maybe in the future, some capsule endoscopy-driven therapeutics. The aim of this review was to evaluate the clinical demands and feasibility of achieving the aforementioned objectives.

  11. Critical swelling of fluctuating capsules

    Science.gov (United States)

    Diamant, Haim; Haleva, Emir

    2009-03-01

    In many natural transport processes the solute molecules to be transported are encapsulated in semipermeable, flexible membrane vesicles of micron size. We study the swelling of such fluctuating capsules, as the number of encapsulated particles is increased, or the concentration of the outer solution is decreased. The approach to the maximum volume-to-area ratio and the associated buildup of membrane tension involve a continuous phase transition and follow universal scaling laws. The criticality and its features are model-independent, arising solely from the interplay between volume and surface degrees of freedom.ootnotetextE. Haleva and H. Diamant, Phys. Rev. Lett. 101, 078104 (2008).

  12. Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract.

    Science.gov (United States)

    Tabatabaei, Ali; Hasanlou, Narges; Kheirkhah, Ahmad; Mansouri, Mohammadreza; Faghihi, Houshang; Jafari, Hajar; Arefzadeh, Alireza; Moghimi, Sasan

    2014-07-01

    To compare the accuracy of 3 imaging modalities for preoperative evaluation of the posterior lens capsule in traumatic cataract. Farabi Eye Hospital, Tehran, Iran. Case series. The study comprised eyes with traumatic cataract opaque enough to prevent visualization of the posterior lens capsule on slitlamp examination. To detect posterior lens capsule rupture before surgery, imaging was performed with 20 MHz echography (Eye Cubed), anterior segment optical coherence tomography (AS-OCT) (Visante model 1000), and Scheimpflug imaging (Pentacam). All patients subsequently had cataract extraction, and the intraoperative findings of the posterior lens capsule were compared with the preoperative findings of the imaging modalities. The study enrolled 21 eyes of 21 patients (20 men, 1 woman) with a mean age of 31.5 years ± 1.45 (SD). The nature of trauma was blunt (5 eyes) or sharp (16 eyes). To detect posterior lens capsule rupture, the sensitivity and specificity were, respectively, 80% and 86% for 20 MHz echography, 71% and 77% for AS-OCT, and 62% and 57% for Scheimpflug imaging (95% confidence intervals: sensitivity, 30.00-90.32; specificity, 54.81-92.95). Insufficient resolution for posterior lens capsule evaluation occurred in 33.3% cases for AS-OCT and 57.1% cases for Scheimpflug imaging. The accuracy of 20 MHz echography, AS-OCT, and Scheimpflug imaging was 76.1%, 61.9%, and 42.9%, respectively. In the evaluation of the posterior lens capsule in eyes with traumatic cataract, 20 MHz echography had higher accuracy than AS-OCT and Scheimpflug imaging. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. All rights reserved.

  13. Indirect MR arthrographic findings of adhesive capsulitis.

    Science.gov (United States)

    Song, Kyoung Doo; Kwon, Jong Won; Yoon, Young Cheol; Choi, Sang-Hee

    2011-12-01

    The objective of our study was to compare the indirect MR arthrographic findings of patients with adhesive capsulitis and patients without adhesive capsulitis. Indirect MR arthrograms of 35 patients (21 women, 14 men; mean age, 50.1 years) diagnosed with adhesive capsulitis clinically were compared with indirect MR arthrograms of 45 patients (23 women, 22 men; mean age, 48.9 years) without adhesive capsulitis. Joint capsule thickness in the axillary recess and the thicknesses of the enhancing portion of the axillary recess and the rotator interval were, respectively, evaluated on coronal T2-weighted images and coronal and sagittal fat-suppressed enhanced T1-weighted images by two radiologists independently. Reliability was studied using the intraclass correlation coefficient (ICC). Receiver operating characteristic (ROC) curves were compared. Patients with adhesive capsulitis had significantly thickened joint capsules in the axillary recess and a thickened enhancing portion in the axillary recess and in the rotator interval. The difference in the thicknesses of the enhancing portion in the axillary recess and in the rotator interval were significantly greater than the difference in joint capsule thicknesses in the axillary recess between the adhesive capsulitis group and the control group (p capsule in the axillary recess and the thicknesses of the enhancing portion of the axillary recess and the rotator interval were 0.797, 0.861, and 0.847, respectively. An abundance of enhancing tissue in the rotator interval and thickening and enhancement of the axillary recess are signs suggestive of adhesive capsulitis on indirect MR arthrography.

  14. DIABETES AND SHOULDER ADHESIVE CAPSULITIS

    Directory of Open Access Journals (Sweden)

    J. Mohanakrishnan

    2016-08-01

    Full Text Available Background: Adhesive capsulitis (AC of shoulder is a common condition encountered by physical therapists in their routine outpatient care services; AC of shoulder is as by itself being a self limiting disorder lasts from months to years causing pain and discomfort to the patients. The condition is commonly associated with Diabetes mellitus or other co morbidities. The incidence of AC is high among diabetic individuals and it becomes mandatory on the part of physical therapists and other health professionals to approach this issue on a holistic manner. This paper deals with the importance of a physiotherapist role in prevention and dealing with the causative factors of AC and not merely its symptom. Methods: Extensive literature review was done from the electronic data bases, Systematic reviews and critical reviews from Pub med indexed journals and other peer reviewed publications across the globe. Results: It was not the type of diabetes but the duration of the disease and the glycemic index, marking the causative factor for adhesive capsulitis of shoulder. Conclusion: It may be concluded that physiotherapist play a vital role in identifying the pre-diabetic or a diabetic state of an individual reporting in a multi disciplinary set up with a AC of shoulder, and also has a role in the prevention of AC by helping the individual to maintain a good glycemic control with a holistic approach which includes aerobic exercises, General Flexibility exercises, Weight management and Yoga therapy.

  15. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  16. The future of wireless capsule endoscopy.

    Science.gov (United States)

    Swain, Paul

    2008-07-14

    We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.

  17. CONGENITAL ANTERIOR TIBIOFEMURAL SUBLUXATION

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2008-06-01

    Full Text Available Congenital anterior tibiofemoral subluxation is an extremely rare disorder. All reported cases accompanied by other abnormalities and syndromes. A 16-year-old high school girl referred to us with bilateral anterior tibiofemoral subluxation as the knees were extended and reduced at more than 30 degrees flexion. Deformities were due to tightness of the iliotibial band and biceps femuris muscles and corrected by surgical release. Associated disorders included bilateral anterior shoulders dislocation, short metacarpals and metatarsals, and right calcaneuvalgus deformity.

  18. Adhesive capsulitis of the shoulder: MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab [Eulji Univ. School of Medicine, Taejon (Korea, Republic of); Kwon, Soon Tae [Chungnam National Univ. College of Medicine, Taejon (Korea, Republic of)

    2001-07-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics.

  19. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  20. Anterior ankle impingement

    NARCIS (Netherlands)

    Tol, Johannes L.; van Dijk, C. Niek

    2006-01-01

    The anterior ankle impingement syndrome is a clinical pain syndrome that is characterized by anterior ankle pain on (hyper) dorsiflexion. The plain radiographs often are negative in patients who have anteromedial impingement. An oblique view is recommended in these patients. Arthroscopic excision of

  1. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  2. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....

  3. Colon capsule endoscopy: toward the future.

    Science.gov (United States)

    Muguruma, Naoki; Tanaka, Kumiko; Teramae, Satoshi; Takayama, Tetsuji

    2017-02-01

    Colon capsule endoscopy is a wireless and minimally invasive technique for visualization of the whole colon. With recent improvements of technical features in second-generation systems, a more important role for colon capsule endoscopy is rapidly emerging. Although several limitations and drawbacks are yet to be resolved, its usefulness as a tool for colorectal cancer screening and monitoring disease activity in inflammatory bowel diseases has become more apparent with increased use. Further investigations, including multicenter trials, are required to evaluate the substantial role of the colon capsule in managing colorectal diseases.

  4. The environmental psychology of capsule habitats.

    Science.gov (United States)

    Suedfeld, P; Steel, G D

    2000-01-01

    Capsule habitats make it possible for human beings to survive and function in environments that would otherwise be lethal, such as space, the ocean depths, and the polar regions. The number of people entering capsules in the course of their work or for purposes of recreation is constantly increasing. However, long-term living in such habitats imposes physical and psychological risks as well as offering opportunities and benefits. This paper reviews what is known about the environmental, social, and personality aspects of adaptation to capsules, including sources of stress, selection criteria, obstacles to and facilitators of adequate coping, changes in group interaction, the role of temporal factors, and post-mission consequences.

  5. Polyamide capsules via soft templating with oil drops-1. Morphological studies of the capsule wall.

    Science.gov (United States)

    Essawy, Hisham; Tauer, Klaus

    2010-02-01

    Poly(terephthalamide) microcapsules can be reproducibly and easily prepared by interfacial polycondensation around emulsion droplets in water. Oil drops of cyclohexane/chloroform mixture stabilized with poly(vinyl alcohol) containing terephthaloylchloride serve as soft template. The interfacial polycondensation starts immediately after addition of an amine mixture (hexamethylenediamine/diethylenetriamine). Light and scanning electron microscopy prove the formation of capsules with size distribution in the range from a few up to 100 microm depending on particular composition of the reaction mixture. The morphology of the capsule wall is characterized by precipitated particles. If instead of pure organic solvents a reactive oil phase is used as template, the capsules can serve in subsequent reactions as templates for the synthesis of composite particles. In this way, styrene can be radically polymerized inside the capsule leading to composite capsules. The capsule morphology is determined by the partition of all components between all phases.

  6. Arterial blood supply to midbrain, thalamus and internal capsule on CT, 3

    International Nuclear Information System (INIS)

    Takeshita, Gen; Ottomo, Michinori; Sasaki, Taisuke; Fukuda, Eiko.

    1984-01-01

    The selective injection of dye into the anterior choroidal artery (blue), the medial posterior choroidal artery (green), and the lateral posterior choroidal artery (red), using seven post-mortem brains, was performed. After fixation, sections parallel with the orbito-meatal line were obtained. The distribution of the anterior choroidal artery was visualized in the uncal region of the temporal lobe and the cerebral peduncle below the slice of the third ventricle. On the slice of the third ventricle, the lateral part of the geniculate region, the globus pallidus, and the posterior limb of the internal capsule were supplied by the anterior choroidal artery. The blood supply of the posterior limb of the internal capsule was also demonstrated on the slice of the anterior horn and on the body of the lateral ventricle. The distribution of the medial posterior choroidal artery was visualized in the tegmentum of the midbrain below the slice of the third ventricle, and on the slice of the anterior horn, the pineal body and the posterior part of the thalamus were also supplied. The distribution of the lateral posterior choroidal artery was visualized in the lateral part of the midbrain, around the red nucleus, below the slice of the third ventricle, and on the slice of the third ventricle, the upper part of the cerebral peduncle, the posterior part of the hypothalamus, and the medial part of the geniculate region were also supplied. Also, distribution to the medial and posterior parts of the thalamus was noted on the slice of the anterior horn. It was quite useful to identify the distribution of each choroidal artery on CT sections for the CT diagnosis of cerebrovascular disorders. (author)

  7. Adhesive capsulitis of the shoulder: pain intensity and distribution.

    Science.gov (United States)

    Candela, V; Giannicola, G; Passaretti, D; Venditto, T; Gumina, S

    2017-12-01

    Papers regarding adhesive capsulitis (AC) of the shoulder focused on etiology, epidemiology, diagnosis, and treatment; until now, information on shoulder pain characteristics is still scarce. Our aim was to analyze pain intensity and distribution in patients with AC. The study group was composed of 278 (133M-145F) consecutive patients with AC. After diagnosis, shoulder pain distribution was assessed through an upper limb pain map and pain intensity through a visual analog scale. Patients were distinguished on the basis of gender, age, time elapsed from onset of symptoms, and severity of functional limitation. Data were submitted to statistical analysis. Intensity of shoulder pain caused by AC was higher in females (p pain arose from more than 3 months suffered a lower intensity of shoulder pain. Furthermore, pain intensity was higher in the most severe form of AC (active forward flexion Pain was localized predominantly on the anterior aspect of the shoulder (dermatomes C5-C6) and rarely extended beyond the distal third of the arm. No differences were found in pain distribution between male and female, between patients with pain from less or more than 3 months and between different levels of AC severity (p > 0.05). Shoulder pain due to AC may be influenced by gender and severity of functional limitation. AC pain distribution principally involves anterior aspect of the shoulder with downward extension of the arm until its distal third. Level IV.

  8. Therapeutic Capsule Endoscopy: Opportunities and Challenges

    Directory of Open Access Journals (Sweden)

    Mahdi Rasouli

    2011-01-01

    Full Text Available The increasing demand for non-invasive (or less-invasive monitoring and treatment of medical conditions has attracted both physicians and engineers to work together and investigate new methodologies. Wireless capsule endoscopy is a successful example of such techniques which has become an accepted routine for diagnostic inspection of the gastrointestinal tract. This method offers a non-invasive alternative to traditional endoscopy and provides the opportunity for exploring distal areas of the small intestine which are otherwise not accessible. Despite these advantages, wireless capsule endoscopy is still limited in functionality compared to traditional endoscopy. Wireless capsule endoscopes with advanced functionalities, such as biopsy or drug delivery, are highly desirable. In this article, the current status of wireless capsule endoscopy is reviewed together with some of its possible therapeutic applications as well as the existing challenges.

  9. CAPSULE REPORT: HARD CHROME FUME ...

    Science.gov (United States)

    All existing information which includes the information extrapolated from the Hard Chrome Pollution Prevention Demonstration Project(s) and other sources derived from plating facilities and industry contacts, will be condensed and featured in this document. At least five chromium emission prevention/control devices have been tested covering a wide spectrum of techniques currently in use at small and large-sized chrome metal plating shops. The goal for limiting chromium emissions to levels specified in the MACT Standards are: (1) 0.030 milligrams per dry standard cubic meter of air (mg/dscm) for small facilities with existing tanks, (2) 0.015 mg/dscm for small facilities with new tanks or large facilities with existing or new tanks. It should be emphasized that chemical mist suppressants still have quality issues and work practices that need to be addressed when they are used. Some of the mist suppressants currently in use are: one-, two-, and three-stage mesh pad mist eliminators; composite mesh pad mist eliminators; packed-bed scrubbers and polyballs. This capsule report should, redominantly, emphasize pollution prevention techniques and include, but not be restricted to, the afore-mentioned devices. Information

  10. Capsule production by Pseudomonas aeruginosa

    Energy Technology Data Exchange (ETDEWEB)

    Lynn, A.R.

    1984-01-01

    Mucoid strains of Pseudomonas aeruginosa, associated almost exclusively with chronic respiratory infections in patients with cystic fibrosis, possess a capsule composed of alginic acid similar to one produced by Azotobacter vinelandii. Recent reports have provided evidence that the biosynthetic pathway for alginate in P. aeruginosa may differ from the pathway proposed for A. vinelandii in that synthesis in P. aeruginosa may occur by way of the Entner-Doudoroff pathway. Incorporation of isotope from (6-/sup 14/C)glucose into alginate by both P. aueroginosa and A. vinelandii was 10-fold greater than that from either (1-/sup 14/C)/sup -/ or (2-/sup 14/C)glucose, indicating preferential utilization of the bottom half of the glucose molecule for alginate biosynthesis. These data strongly suggest that the Entner-Doudoroff pathway plays a major role in alginate synthesis in both P. aeruginosa and A. vinelandii. The enzymes of carbohydrate metabolism in mucoid strains of P. aeruginosa appear to be unchanged whether alignate is actively produced or not and activities do not differ significantly from nonmucoid strain PAO.

  11. The history of time for capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N

    2017-05-01

    Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.

  12. Adhesive capsulitis: review of imaging and treatment

    International Nuclear Information System (INIS)

    Harris, Guy; Bou-Haider, Pascal; Harris, Craig

    2013-01-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented.

  13. Radioactive gas-containing polymeric capsule

    International Nuclear Information System (INIS)

    Winchell, H.S.; Lewis, R.E.

    1975-01-01

    A disposable ventilation study system for dispensing a single patient dosage of gaseous radioisotopes to patients for pulmonary function studies is disclosed. A gas impermeable capsule encloses the gaseous radioisotope and is stored within a radioactivity shielding body of valve means which shears the capsule to dispense the radioisotope to the patient. A breathing bag receives the patient's exhalation of the radioisotope and permits rebreathing of the radioisotope by the patient. 18 claims, 7 drawing figures

  14. Congenital anterior urethral diverticulum

    International Nuclear Information System (INIS)

    Jung, Hyun Sub; Chung, Young Sun; Suh, Chee Jang; Won, Jong Jin

    1985-01-01

    Two cases of congenital anterior urethral diverticular which have occurred in a 4 year old and one month old boy are presented. Etiology, diagnostic procedures, and its clinical results are briefly reviewed

  15. Anterior knee pain

    Science.gov (United States)

    ... thighbone where the kneecap normally rests is too shallow. You have flat feet. Anterior knee pain is ... the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein should ...

  16. Identifying anterior segment crystals.

    OpenAIRE

    Hurley, I W; Brooks, A M; Reinehr, D P; Grant, G B; Gillies, W E

    1991-01-01

    A series of 22 patients with crystals in the anterior segment of the eye was examined by specular microscopy. Of 10 patients with hypermature cataract and hyperrefringent bodies in the anterior chamber cholesterol crystals were identified in four patients and in six of the 10 in whom aspirate was obtained cholesterol crystals were demonstrated in three, two of these having shown crystals on specular microscopy. In 10 patients with intracorneal crystalline deposits, cholesterol crystals were f...

  17. Evaluation of Adhesive Capsulitis of the Shoulder With Fat-Suppressed T2-Weighted MRI: Association Between Clinical Features and MRI Findings.

    Science.gov (United States)

    Park, Sunghoon; Lee, Doo-Hyung; Yoon, Seung-Hyun; Lee, Hyun Young; Kwack, Kyu-Sung

    2016-07-01

    The purpose of this study was to examine the association between clinical features and MRI findings in adhesive capsulitis of the shoulder. This study included 103 patients (41 men, 62 women) with adhesive capsulitis. The MRI findings were correlated with pain intensity, range of motion, and clinical stage. Joint capsule edema in the axillary recess, extracapsular edema, obliteration of the subcoracoid fat triangle, and effusion in the long head biceps tendon sheath were assessed by two radiologists using fat-suppressed T2-weighted images. Joint capsule thickness in the axillary recess and degree of external rotation during MRI were also measured. Intraclass correlation coefficient and kappa values were obtained. Associations between MRI findings and clinical features were assessed by statistical analyses. Anterior extracapsular edema was associated with range of motion on external rotation and abduction (p capsule edema in the humeral portion of the axillary recess was associated with range of motion on external rotation (p = 0.01). Joint capsule thickness in the humeral portion of the axillary recess and height of the axillary recess were associated with pain intensity (p capsule edema in the humeral portion of the axillary recess and obliteration of the subcoracoid fat triangle were significantly more common in the early stages of adhesive capsulitis (p capsule thickness in the humeral portion of the axillary recess at stage 1 (4.67 ± 1.73 mm) was significantly different from the thickness at the later stages (stage 2, 3.73 ± 1.49 mm; stages 3 and 4, 3.67 ± 1.44 mm) (p adhesive capsulitis.

  18. An MRI study of symptomatic adhesive capsulitis.

    Science.gov (United States)

    Zhao, Wen; Zheng, Xiaofeng; Liu, Yuying; Yang, Wenlu; Amirbekian, Vardan; Diaz, Luis E; Huang, Xudong

    2012-01-01

    Appilication of MR imaging to diagnose Adhesive Capsulitis (AC) has previously been described. However, there is insufficient information available for the MRI analysis of AC. This study is to describe and evaluate the pathomorphology of the shoulder in Asian patients with AC compared to healthy volunteers. 60 Asian patients with clinically diagnosed AC and 60 healthy volunteers without frozen shoulder underwent MRI of the shoulder joint. All subjects who were age- and sex-matched control ones underwent routine MRI scans of the affected shoulder, including axial, oblique coronal, oblique sagittal T1WI SE and coronal oblique T2WI FSE sequences. Significant abnormal findings were observed on MRI, especially at the rotator cuff interval. The coracohumeral ligament (CHL), articular capsule thickness in the rotator cuff interval as well as the fat space under coracoid process were evaluated. MRI showed that patients with adhesive capsulitis had a significantly thickened coracohumeral ligament and articular capsule in the rotator cuff interval compared to the control subjects (4.2 vs. 2.4 mm, 7.2 vs. 4.4 mm; padhesive capsulitis compared with control subjects (73% vs. 13%, 26% vs. 1.6%; padhesive capsulitis than in control subjects. With regards to the inter-observer variability, two MR radiologists had an excellent kappa value of 0.86. MRI can be used to show characteristic findings in diagnosing AC. Thickening of the CHL and the capsule at the rotator cuff interval and complete obliteration of the fat triangle under the coracoid process have been shown to be the most characteristic MR findings seen with AC.

  19. An MRI study of symptomatic adhesive capsulitis.

    Directory of Open Access Journals (Sweden)

    Wen Zhao

    Full Text Available BACKGROUND: Appilication of MR imaging to diagnose Adhesive Capsulitis (AC has previously been described. However, there is insufficient information available for the MRI analysis of AC. This study is to describe and evaluate the pathomorphology of the shoulder in Asian patients with AC compared to healthy volunteers. METHODOLOGY/PRINCIPAL FINDINGS: 60 Asian patients with clinically diagnosed AC and 60 healthy volunteers without frozen shoulder underwent MRI of the shoulder joint. All subjects who were age- and sex-matched control ones underwent routine MRI scans of the affected shoulder, including axial, oblique coronal, oblique sagittal T1WI SE and coronal oblique T2WI FSE sequences. Significant abnormal findings were observed on MRI, especially at the rotator cuff interval. The coracohumeral ligament (CHL, articular capsule thickness in the rotator cuff interval as well as the fat space under coracoid process were evaluated. MRI showed that patients with adhesive capsulitis had a significantly thickened coracohumeral ligament and articular capsule in the rotator cuff interval compared to the control subjects (4.2 vs. 2.4 mm, 7.2 vs. 4.4 mm; p<0.05. Partial or complete obliteration of the subcoracoid fat triangle was significantly more frequent in patients with adhesive capsulitis compared with control subjects (73% vs. 13%, 26% vs. 1.6%; p<0.001. Synovitis-like abnormality around the long biceps tendon was significantly more common in patients with adhesive capsulitis than in control subjects. With regards to the inter-observer variability, two MR radiologists had an excellent kappa value of 0.86. CONCLUSIONS/SIGNIFICANCE: MRI can be used to show characteristic findings in diagnosing AC. Thickening of the CHL and the capsule at the rotator cuff interval and complete obliteration of the fat triangle under the coracoid process have been shown to be the most characteristic MR findings seen with AC.

  20. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  1. Video capsule endoscopy of the small bowel.

    Science.gov (United States)

    Eliakim, Rami

    2013-03-01

    Small bowel capsule endoscopy (SBCE) was introduced 13 years ago by Given Imaging (Yokneam, Israel). It has become one of the most important investigational tools of the small bowel. The capsule is swallowed with water after a 12 h fast, propelled via peristalsis through the gastrointestinal tract and excreted naturally. A nonvideo patency capsule was developed to confirm functional patency of the gastrointestinal tract. Four additional companies have introduced competitive small bowel video capsules, some of which are Food and Drug Admistration (FDA) approved. Due to the easiness of the procedure, SBCE has become a first-line tool to detect small bowel abnormalities. The main indications for SBCE include obscure gastrointestinal bleeding, suspected Crohn's disease, small bowel tumors and practically any abnormal small bowel imaging. New indications are emerging like small bowel motility and monitoring of drug therapy and mucosal healing. The present review will describe the available capsules in the market, the procedure itself, present indications and future expectations. It will focus on the PillCam SB of Given Imaging as it is the one on which most of the literature is written. Over the past 10 years, SBCE has become a routine, first-line investigational tool of many small bowel pathologies.

  2. Clinical evaluation of arthroscopic treatment of shoulder adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the results of arthroscopic releases performed in patients with adhesive capsulitis refractory to conservative treatment. METHODS: This was a retrospective study, conducted between 1996 and 2012, which included 56 shoulders (52 patients that underwent surgery; 38 were female, and 28 had the dominant side affected. The mean age was 51 (29-73 years. The mean follow-up was 65 (12-168 months and the mean preoperative time was 8.9 (2-24 months. According to Zukermann's classification, 23 cases were considered primary and 33 secondary. With the patient in the lateral decubitus position, circumferential release of the joint capsule was performed: joint debridement; rotator interval opening; coracohumeral ligament release; anterior, posterior, inferior, and finally antero-inferior capsulotomy. A subscapularis tenotomy was performed when necessary. All patients underwent intense physical therapy in the immediate postoperative period. In 33 shoulders, an interscalene catheter was implanted for anesthetic infusion. Functional results were evaluated by the UCLA criteria. RESULTS: Improved range of motion was observed: mean increase of 45° of elevation, 41° of external rotation and eight vertebral levels of medial rotation. According to the UCLA score excellent results were obtained in 25 (45% patients; good, in 24 (45%; fair, in two (3%; and poor, in two (7%. Patients who had undergone inferior capsulotomy achieved better results. Only 8.8% of patients who used the anesthetic infusion catheter underwent postoperative manipulation. Seven patients had complications. CONCLUSION: There was improvement in pain and range of motion. Inferior capsulotomy leads to better results. The use of the interscalene infusion catheter reduces the number of re-approaches.

  3. CORR®ORS Richard A. Brand Award: Clinical Trials of a New Treatment Method for Adhesive Capsulitis.

    Science.gov (United States)

    Badalamente, Marie A; Wang, Edward D

    2016-11-01

    Conservative and even surgical management of adhesive capsulitis often is prolonged and painful. Management of adhesive capsulitis is lacking evidence-based controlled clinical trials. We asked: (1) Does a collagenase clostridium histolyticum (CCH) injection lyse shoulder capsule collagen in adhesive capsulitis and at what dose? (2) Can a shoulder capsule injection be administered extraarticularly? (3) Do CCH injections result in better scores for pain and function than can be achieved with physical therapy among patients with adhesive capsulitis? First, 60 patients with adhesive capsulitis were evaluated by clinical examination. To make the diagnosis of adhesive capsulitis, a patient had to have restricted active ROM of at least 60° in total active ROM in the affected shoulder compared with the unaffected contralateral shoulder; with the scapula stabilized, external rotation with the elbow at the side was a very important determinant. Patients were randomized to receive a single injection of 0.5 mL placebo or 0.145, 0.29, or 0.58 mg CCH. All 60 patients were followed up at 30 days. After that, if patients did not attain treatment thresholds they were eligible for up to five open-label 0.58-mg collagenase injections. For the longer-term followup in the open-label phase, 53 patients (83%) were followed to 12 months, 46 (77%) for 24 months, 36 (60%) for 36 months, 37 (62%) for 48 months, and 25 (42%) for 60 months. The extraarticular injection was directed at the anterior shoulder capsule with the patient in the supine position. To prove that these injections could be delivered reliably to the anterior shoulder capsule extraarticularly, the next study involved volunteers without adhesive capsulitis, in which 10 volunteers received a 10-mL injection of normal saline under ultrasound guidance. Finally, to determine the efficacy and dosing of CCH, four cohorts of 10 patients received up to three ultrasound-guided injections separated by 21 days. These injections were

  4. The first capsule implosion experiments on Orion

    International Nuclear Information System (INIS)

    Garbett, W J; Horsfield, C J; Gales, S G; Leatherland, A E; Rubery, M S; Coltman, J E; Meadowcroft, A E; Rice, S J; Simons, A J; Woolhead, V E

    2016-01-01

    Direct drive capsule implosions are being developed on the Orion laser at AWE as a platform for ICF and HED physics experiments. The Orion facility combines both long pulse and short-pulse beams, making it well suited for studying the physics of alternative ignition approaches. Orion implosions also provide the opportunity to study aspects of polar direct drive. Limitations on drive symmetry from the relatively small number of laser beams makes predictive modelling of the implosions challenging, resulting in some uncertainty in the expected capsule performance. Initial experiments have been fielded to evaluate baseline capsule performance and inform future design optimization. Highly promising DD fusion neutron yields in excess of 10 9 have been recorded. Results from the experiments are presented alongside radiation-hydrocode modelling. (paper)

  5. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Freud, A.; Hirshfeld, N.; Canfi, A.; Melamud, Y.

    1997-01-01

    Radioiodine ( 131 I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  6. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  7. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  8. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    Science.gov (United States)

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  9. Capsule storage and density-analog techniques

    International Nuclear Information System (INIS)

    Paxton, H.C.

    1975-05-01

    Density-analog schemes for describing critical arrays of fissile units have a long history. They originated as methods for generalizing results of subcritical measurements on weapon capsules. Such measurements were needed to establish reasonably efficient rules for capsule storage. Although specific density-analog models have been improved throughout the years, they are now largely replaced by comprehensive tabulations of critical-lattice parameters. Certain simplified forms are still useful as convenient formulas for extrapolation or for gross sorting of safety features. (U.S.)

  10. Adhesive capsulitis: review of imaging and treatment.

    Science.gov (United States)

    Harris, Guy; Bou-Haidar, Pascal; Harris, Craig

    2013-12-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented. © 2013 The Royal Australian and New Zealand College of Radiologists.

  11. Treatment of adhesive capsulitis: a review

    Science.gov (United States)

    D’Orsi, Giovanni Maria; Via, Alessio Giai; Frizziero, Antonio; Oliva, Francesco

    2012-01-01

    Summary Adhesive capsulitis is a condition “difficult to define, difficult to treat and difficult to explain from the point of view of pathology”. This Codman’s assertion is still actual because of a variable nomenclature, an inconsistent reporting of disease staging and many types of treatment. There is no consensus on how the best way best to manage patients with this condition, so we want to provide an evidence-based overview regarding the effectiveness of conservative and surgical interventions to treat adhesive capsulitis. PMID:23738277

  12. Anterior cruciate ligament injury, reconstruction, and the optimization of outcome

    Directory of Open Access Journals (Sweden)

    James Philip Bliss

    2017-01-01

    Full Text Available Anterior cruciate ligament reconstruction (ACLR provides an established surgical intervention to control pathological tibiofemoral translational and rotational movement. ACLR is a safe and reproducible intervention, but there remains an underlying rate of failure to return to preinjury sporting activity levels. Postoperative pathological laxity and graft reinjury remain concerns. Previously, unrecognized meniscal lesions, disruption of the lateral capsule, and extracapsular structures offer potential avenues to treat and to therefore improve kinematic outcome and functional results, following reconstruction. Addressing laterally based injuries may also improve the durability of intraarticular ACLR. Improving the anterior cruciate ligament (ACL graft replication of the normal ACL attachment points on the femur and the tibia, using either double bundle or anatomical single bundle techniques, improves kinematics, which may benefit outcome and functionality, following reconstruction.

  13. Anterior Cruciate Ligament Injury, Reconstruction, and the Optimization of Outcome

    Science.gov (United States)

    Bliss, James Philip

    2017-01-01

    Anterior cruciate ligament reconstruction (ACLR) provides an established surgical intervention to control pathological tibiofemoral translational and rotational movement. ACLR is a safe and reproducible intervention, but there remains an underlying rate of failure to return to preinjury sporting activity levels. Postoperative pathological laxity and graft reinjury remain concerns. Previously, unrecognized meniscal lesions, disruption of the lateral capsule, and extracapsular structures offer potential avenues to treat and to therefore improve kinematic outcome and functional results, following reconstruction. Addressing laterally based injuries may also improve the durability of intraarticular ACLR. Improving the anterior cruciate ligament (ACL) graft replication of the normal ACL attachment points on the femur and the tibia, using either double bundle or anatomical single bundle techniques, improves kinematics, which may benefit outcome and functionality, following reconstruction. PMID:28966384

  14. anterior hyaloidal fibrovascular proliferation

    African Journals Online (AJOL)

    Okonkwo

    It most commonly occurs after phakic vitrectomy and scleral buckling for diabetic traction retinal detachment. It usually manifests with haemorrhage into the vitreous cavity or anterior hyaloid 3 to 12 weeks after vitrectomy and is the result of fibrovascular proliferation from the peripheral retina extending toward the equator of ...

  15. Supracapsular glued intraocular lens in progressive subluxated cataracts: Technique to retain an intact vitreous face.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Mazzotta, Cosimo; Rechichi, Miguel; Agarwal, Athiya

    2017-03-01

    We describe a technique to prevent late intraocular lens (IOL) subluxation and dislocation that can be associated with progressive zonulopathy. Supracapsular glued IOL fixation is done to retain an intact anterior hyaloid face and avoid vitreous disturbance while providing stable long-term IOL fixation. Phacoemulsification is followed by glued IOL implantation above intact anterior and posterior capsules. Sclerotomies are created ab interno in a supracapsular plane under diametrically opposite lamellar scleral flaps without entering the vitreous cavity. Haptics are externalized in the supracapsular plane and tucked into intrascleral tunnels. Intraoperative or postoperative posterior capsulorhexis or capsulotomy and anterior capsule relaxing cuts can prevent capsule phimosis. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Isolation of Capsulate Bacteria from Acute Dentoalveolar Abscesses

    OpenAIRE

    Lewis, M. A. O.; Milligan, S. G.; MacFarlane, T. W.; Carmichael, F. A.

    2011-01-01

    The presence of a capsule was determined for 198 bacterial strains (57 facultative anaerobes, 141 strict anaerobes) isobdted from pus samples aspirated from 40 acute dentoalveolar abscesses. A total of 133 (67 per cent) of the isolates (42 facultative anaerobes, 91 strict anaerobes) were found to have a capsule. Possession ofa capsule may in part explain the apparent pathogenicity of the bacterial species encountered in acute dentoalveolar abscess.Keywords - Bacterial capsule; Acute dentoalve...

  17. Ultrasound capsule endoscopy: sounding out the future.

    Science.gov (United States)

    Cox, Benjamin F; Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P; Desmulliez, Marc P Y; Steele, Robert J C; Näthke, Inke; Cochran, Sandy

    2017-05-01

    Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently.

  18. Calcitonin effects on shoulder adhesive capsulitis.

    Science.gov (United States)

    Rouhani, Alireza; Mardani-Kivi, Mohsen; Bazavar, Mohammadreza; Barzgar, Mahmood; Tabrizi, Ali; Hashemi-Motlagh, Keyvan; Saheb-Ekhtiari, Khashayar

    2016-08-01

    Adhesive capsulitis (frozen shoulder) is a relatively prevalent disease of shoulder and affects soft tissue of glenohumeral joint. Signs include painful restricted motion and disability of the patient in daily activities. Calcitonin is a thyroid hormone, and its effectiveness has been demonstrated in painful conditions. The presents study aims to evaluate the effect of calcitonin in treating shoulder adhesive capsulitis. This double-blinded randomized clinical trial was conducted on 64 patients suffering from shoulder adhesive capsulitis. The intervention and control groups were given intranasal calcitonin and placebo for 6 weeks, respectively. For both groups, physiotherapy and non-steroidal anti-inflammatory drugs were administered correspondingly. The patients were evaluated pre- and post-treatment for shoulder pain and shoulder range of motion (ROM). Shoulder functional outcome (secondary outcome) was evaluated using Disability of Arm, Shoulder, and Hand, Shoulder Pain and Disability Index, and Health Assessment Questionnaire disability criteria. The mean age of patients in calcitonin and control group was 52.4 ± 4.6 and 53.2 ± 4.9, respectively. Demographic characteristics and pre-treatment scores were similar in both groups (all P > 0.05). In post-treatment follow-up, shoulder pain, ROM, and the patients' functional scores were significantly improved in both groups (P adhesive capsulitis with regard to the efficiency in alleviating pain and improving functional outcome. II.

  19. Diagnosis and management of adhesive capsulitis

    OpenAIRE

    Manske, Robert C.; Prohaska, Daniel

    2008-01-01

    Adhesive capsulitis is a musculoskeletal condition that has a disabling capability. This review discusses the diagnosis and both operative and nonoperative management of this shoulder condition that causes significant morbidity. Issues related to medications, rehabilitation, and post surgical considerations are discussed.

  20. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  1. Capsule Endoscopy: New Technology, Old Complication ...

    African Journals Online (AJOL)

    Wireless capsule endoscopy is a new tool in the armamentarium of the gastroenterologist to evaluate the small bowel non-invasively. It allows improved diagnostic yield with low complication rates relative to traditional modalities. But this new technology has its own set of complications, some which can lead to significant ...

  2. Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.

    Science.gov (United States)

    Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier

    2014-11-14

    Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

  3. Hardware image assessment for wireless endoscopy capsules.

    Science.gov (United States)

    Khorsandi, M A; Karimi, N; Samavi, S; Hajabdollahi, M; Soroushmehr, S M R; Ward, K; Najarian, K

    2016-08-01

    Wireless capsule endoscopy is a new technology in the realm of telemedicine that has many advantages over the traditional endoscopy systems. Transmitted images should help diagnosis of diseases of the gastrointestinal tract. Two important technical challenges for the manufacturers of these capsules are power consumption and size of the circuitry. Also, the system must be fast enough for real-time processing of image or video data. To solve this problem, many hardware designs have been proposed for implementation of the image processing unit. In this paper we propose an architecture that could be used for the assessment of endoscopy images. The assessment allows avoidance of transmission of medically useless images. Hence, volume of data is reduced for more efficient transmission of images by the endoscopy capsule. This is done by color space conversion and moment calculation of images captured by the capsule. The inputs of the proposed architecture are RGB image frames and the outputs are images with converted colors and calculated image moments. Experimental results indicate that the proposed architecture has low complexity and is appropriate for a real-time application.

  4. Wireless Capsule Enteroscopy in Healthy Volunteers.

    Science.gov (United States)

    Tachecí, Ilja; Bradna, Petr; Douda, Tomáš; Baštecká, Drahomíra; Kopáčová, Marcela; Rejchrt, Stanislav; Lutonský, Martin; Soukup, Tomáš; Bureš, Jan

    The aim of our prospective study was to define endoscopy appearance of the small bowel in healthy volunteers. Forty-two healthy volunteers underwent wireless capsule endoscopy, clinical investigation, laboratory tests, and completed a health-status questionnaire. All subjects were available for a 36-month clinical follow-up. Eleven subjects (26%) had fully normal endoscopy findings. Remaining 31 persons (74%), being asymptomatic, with normal laboratory results, had some minor findings at wireless capsule endoscopy. Most of those heterogeneous findings were detected in the small intestine (27/31; 87%), like erosions and/or multiple red spots, diminutive polyps and tiny vascular lesions. During a 36-month clinical follow-up, all these 42 healthy volunteers remained asymptomatic, with fully normal laboratory control. Significant part of healthy subjects had abnormal findings at wireless capsule endoscopy. These findings had no clinical relevance, as all these persons remained fully asymptomatic during a 36-month follow-up. Such an endoscopic appearance would be previously evaluated as "pathological". This is a principal report alerting that all findings of any control group of wireless capsule endoscopic studies must be evaluated with caution.

  5. Wireless Capsule Enteroscopy in Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    Ilja Tachecí

    2016-09-01

    Full Text Available Introduction: The aim of our prospective study was to define endoscopy appearance of the small bowel in healthy volunteers. Method: Forty-two healthy volunteers underwent wireless capsule endoscopy, clinical investigation, laboratory tests, and completed a health-status questionnaire. All subjects were available for a 36-month clinical follow-up. Results: Eleven subjects (26% had fully normal endoscopy findings. Remaining 31 persons (74%, being asymptomatic, with normal laboratory results, had some minor findings at wireless capsule endoscopy. Most of those heterogeneous findings were detected in the small intestine (27/31; 87%, like erosions and/or multiple red spots, diminutive polyps and tiny vascular lesions. During a 36-month clinical follow-up, all these 42 healthy volunteers remained asymptomatic, with fully normal laboratory control. Conclusions: Significant part of healthy subjects had abnormal findings at wireless capsule endoscopy. These findings had no clinical relevance, as all these persons remained fully asymptomatic during a 36-month follow-up. Such an endoscopic appearance would be previously evaluated as “pathological”. This is a principal report alerting that all findings of any control group of wireless capsule endoscopic studies must be evaluated with caution.

  6. Can we reduce capsule endoscopy reading times?

    NARCIS (Netherlands)

    Westerhof, Jessie; Koornstra, Jan J.; Weersma, Rinse K.

    Background: Analyzing small-bowel capsule endoscopy (CE) images is time Consuming. Objective: To determine the effect of reducing the number Of images on reacting time and interpretation of CE procedures. Design: Two techniques aimed at reducing the number of images to he viewed were Studied. The

  7. Biosorption of lead by Gram-ve capsulated and non-capsulated ...

    African Journals Online (AJOL)

    Citrobacter freundii ) or capsulated (Klebsiella pneumoniae) was characterised. Lead biosorption was found to be influenced by the pH of the solution, initial metal concentration, and amount of the dried powdered cells and contact time. Thus, the ...

  8. Is there an application for wireless capsule endoscopy in horses?

    Science.gov (United States)

    Montgomery, Julia B; Bracamonte, Jose L; Alam, Mohammad Wajih; Khan, Alimul H; Mohammed, Shahed K; Wahid, Khan A

    2017-12-01

    This pilot study assessed wireless capsule endoscopy in horses. Image transmission was achieved with good image quality. Time to exit the stomach was variable and identified as one limitation, together with gaps in image transmission, capsule tumbling, and inability to accurately locate the capsule. Findings demonstrate usefulness and current limitations.

  9. 21 CFR 872.3110 - Dental amalgam capsule.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  10. Anterior cruciate ligament repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100230.htm Anterior cruciate ligament repair - Series—Normal anatomy To use the sharing ... to slide 5 out of 5 Overview The anterior cruciate ligament (ACL) is a ligament in the center of ...

  11. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...

  12. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  13. Utility of MR arthrography in the diagnosis of adhesive capsulitis

    Energy Technology Data Exchange (ETDEWEB)

    Manton, G.L.; Schweitzer, M.E.; Weishaupt, D.; Karasick, D. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States)

    2001-06-01

    Objective. Arthrographically, adhesive capsulitis is characterized by decreased joint volume; histologically, the capsule and synovium are thickened. We therefore compared using MR arthrography the joint volumes and capsule/synovial thickness of patients with and without adhesive capsulitis in order to assess the utility of MR arthrography in diagnosing adhesive capsulitis.Design and patients. The 1.5 T MR arthrography images of 28 subjects with (n=9) and without (n=19) adhesive capsulitis were compared. Adhe- sive capsulitis was diagnosed when there was an injected glenohumeral joint volume of less than 10 ml. Two masked observers working in consensus assessed the images for the relative amount of fluid in the biceps tendon sheath and axillary recess, corrugation at the margin of the capsule, capsule/synovial thickness, abnormalities of the rotator interval capsule, and for the presence of a cuff tear.Results. There was a trend towards differences in capsular and synovial thickness (P>0.07) between the subjects with and without adhesive capsulitis; however, the controls had thicker synovium/capsules. Surprisingly, the amount of fluid in the axillary recess and biceps tendon sheath was not significantly different between the groups (P>0.25). There were more tears of the rotator cuff in controls than in patients with adhesive capsulitis (6, 3 vs 1, 1: complete, partial). Also, both corrugation (7 vs 0) and interval abnormalities (7 vs 0) were more common in the controls.Conclusion. There appear to be no useful MR arthrographic signs of adhesive capsulitis. Capsular/synovial thickness, static fluid volume, and the presence of corrugation are inconclusive as MR arthrographic signs for distinguishing shoulders with adhesive capsulitis from those without. (orig.)

  14. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  15. Ossifying fibroma involving the paranasal sinuses, orbit, and anterior cranial fossa: case report.

    Science.gov (United States)

    Nakagawa, K; Takasato, Y; Ito, Y; Yamada, K

    1995-06-01

    We report a case of ossifying fibroma involving the paranasal sinuses, orbit, and anterior cranial fossa. Ossifying fibroma is a benign fibro-osseous tumor, rarely involving the anterior cranial base. The patient was admitted because of exophthalmos and diplopia. The lesion was totally removed surgically. Grossly, it had a thin osseous capsule. The microscopic examination showed mainly fibrous tissues and lamellar bone trabeculae rimmed by osteoblasts and myxomatous areas in some parts. The histopathological aspect of this entity is discussed with reference to the differential diagnosis from monostotic fibrous dysplasia.

  16. A wireless capsule endoscopy steering mechanism using magnetic field platform.

    Science.gov (United States)

    Alsunaydih, Fahad N; Redoute, Jean-Michel; Yuce, Mehmet R

    2017-07-01

    In this paper, a new steering mechanism for wireless capsule devices is presented. The proposed system consists of a platform generating a magnetic field to direct and control the motion of a capsule. The platform contains an upper and a lower set of electromagnets. A permanent magnet is implanted inside the capsule to initiate the movement, which is set by the magnetic field delivered by the electromagnets. The total magnetic field at the capsule's location is the sum of the contributions of each electromagnet. An experimental setup has been designed for testing and comparing between the performance of the capsule mobility in practice and simulations.

  17. Symptomatic Patency Capsule Retention in Suspected Crohn's Disease

    DEFF Research Database (Denmark)

    Rasmussen, Bjørn; Nathan, Torben; Jensen, Michael Dam

    2016-01-01

    The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two...... patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography...

  18. Fornical and nonfornical projections from the rat hippocampal formation to the anterior thalamic nuclei

    Science.gov (United States)

    Dillingham, Christopher M.; Erichsen, Jonathan T.; O'Mara, Shane M.; Aggleton, John P.

    2015-01-01

    ABSTRACT The hippocampal formation and anterior thalamic nuclei form part of an interconnected network thought to support memory. A central pathway in this mnemonic network comprises the direct projections from the hippocampal formation to the anterior thalamic nuclei, projections that, in the primate brain, originate in the subicular cortices to reach the anterior thalamic nuclei by way of the fornix. In the rat brain, additional pathways involving the internal capsule have been described, linking the dorsal subiculum to the anteromedial thalamic nucleus, as well as the postsubiculum to the anterodorsal thalamic nucleus. Confirming such pathways is essential in order to appreciate how information is transferred from the hippocampal formation to the anterior thalamus and how it may be disrupted by fornix pathology. Accordingly, in the present study, pathway tracers were injected into the anterior thalamic nuclei and the dorsal subiculum of rats with fornix lesions. Contrary to previous descriptions, projections from the subiculum to the anteromedial thalamic nucleus overwhelmingly relied on the fornix. Dorsal subiculum projections to the majority of the anteroventral nucleus also predominantly relied on the fornix, although postsubicular inputs to the lateral dorsal part of the anteroventral nucleus, as well as to the anterodorsal and laterodorsal thalamic nuclei, largely involved a nonfornical pathway, via the internal capsule. © 2015 The Authors Hippocampus Published by Wiley Periodicals, Inc. PMID:25616174

  19. Wireless capsule endoscopy years after Michelassi stricturoplasty for Crohn's disease.

    Science.gov (United States)

    Sciaudone, G; Pellino, G; Guadagni, I; Pezzullo, A; Selvaggi, F

    2010-01-01

    The use of wireless capsule endoscopy in Crohn's disease has been a matter of debate. We report the case of a 27-year-old woman operated for Crohn's disease with a Michelassi stricturoplasty presenting with anaemia. We tested the patient with a patency capsule before undertaking a wireless capsule endoscopy. Although the absorbable capsule was successfully expelled, the wireless capsule was retained next to the distal edge of the Michelassi stricturoplasty, where it revealed an otherwise undetected stenotic recurrence. We successfully treated the recurrence with a Heineke-Mikulicz stricturoplasty on the stenotic outlet of the previous Michelassi, extracting the capsule. We found our treatment effective. We believe that capsule endoscopy can be performed in patients operated on for Crohn's disease, although further studies are needed to clarify its role in patients with long-stricturoplasties and to establish which examination could be the most effective in selecting patients.

  20. Perawatan Ortodontik Gigitan Terbuka Anterior

    Directory of Open Access Journals (Sweden)

    Yuniar Zen

    2014-06-01

    Full Text Available Perawatan gigitan terbuka anterior telah lama dianggap sebagai tantangan bagi ortodontis. Prevalensi gigitan terbuka anterior antara 3,5% hingga 11% terdapat pada berbagai usia dan kelompok etnis, serta ada sekitar 17% pasien ortodonti memiliki gigitan terbuka. Stabilitas hasil perawatan gigitan terbuka anterior sangat sulit, karena adanya kombinasi diskrepansi anteroposterior dengan gigitan terbuka skeletal sehingga dibutuhkan tingkat keterampilan diagnosis dan klinis yang tinggi. Etiologi gigitan terbuka anterior sangat kompleks karena dapat melibatkan skeletal, dental, dan faktor-faktor habitual. Eliminasi faktor etiologi merupakan hal yang penting dalam perawatan gigitan terbuka anterior. Berbagai cara perawatan untuk koreksi gigitan terbuka anterior diantaranya bedah ortognatik dan perawatan ortodontik kamuflase, seperti high-pull headgear, chincup, bite blocks, alatfungsional, pencabutan gigi, multi-loop edgewise archwires dan mini implan. Stabilitas hasil perawatan adalah kriteria yang paling penting dalam menentukan cara perawatan gigitan terbuka anterior. Orthodontic Treatment of Anterior Open Bite. An anterior open bite therapy has long been considered a challenge to orthodontist. The prevalence of anterior openbite range from 3,5 % to 11% among various age and ethnic groups and it has been shown that approximately 17% of orthodontic patients have open bite. Stability of treatment result of anterior open bite with well-maintained results is difficult, because the combination of anteroposteriorly discrepancy with skeletal open bite requires the highest degree of diagnostic and clinical skill. The etiology is complex, potentially involving skeletal, dental and habitual factors. The importance of an anterior open bite therapy is to eliminate the cause of the open bite. Various treatment modalities for the correction of an anterior open bite have been proposed, orthognatic surgery and orthodontic camouflage treatment such as high

  1. Adhesive capsulitis of the hip: a review.

    Science.gov (United States)

    Looney, Colin G; Raynor, Brett; Lowe, Rebecca

    2013-12-01

    Adhesive capsulitis of the hip (ACH) is a rare clinical entity. Similar to adhesive capsulitis of the shoulder, ACH is characterized by a painful decrease in active and passive range of motion as synovial inflammation in the acute stages of the disease progresses to capsular fibrosis in the chronic stages. Once other diagnoses have been ruled out, management of ACH is tailored to reduce inflammation in the acute stages with NSAIDs, intra-articular steroid injections, and targeted physical therapy while biomechanical dysfunction in the spine, hip, sacroiliac joint, or lower limb joints is addressed. In chronic stages of the disease, intervention should focus on decreasing the progression of fibrotic changes and regaining range of motion through aggressive physical therapy. Interventions described for chronic ACH include manipulation under anesthesia; pressure dilatation; and open or arthroscopic synovectomy, lysis of adhesions, and capsular release. Surgical intervention should be considered only after failure of a minimum 3-month course of nonsurgical treatment.

  2. Polymeric multilayer capsules in drug delivery.

    Science.gov (United States)

    De Cock, Liesbeth J; De Koker, Stefaan; De Geest, Bruno G; Grooten, Johan; Vervaet, Chris; Remon, Jean Paul; Sukhorukov, Gleb B; Antipina, Maria N

    2010-09-17

    Recent advances in medicine and biotechnology have prompted the need to develop nanoengineered delivery systems that can encapsulate a wide variety of novel therapeutics such as proteins, chemotherapeutics, and nucleic acids. Moreover, these delivery systems should be "intelligent", such that they can deliver their payload at a well-defined time, place, or after a specific stimulus. Polymeric multilayer capsules, made by layer-by-layer (LbL) coating of a sacrificial template followed by dissolution of the template, allow the design of microcapsules in aqueous conditions by using simple building blocks and assembly procedures, and provide a previously unmet control over the functionality of the microcapsules. Polymeric multilayer capsules have recently received increased interest from the life science community, and many interesting systems have appeared in the literature with biodegradable components and biospecific functionalities. In this Review we give an overview of the recent breakthroughs in their application for drug delivery.

  3. Technology of swallowable capsule for medical applications

    OpenAIRE

    Intzes, I; Meng, H; Cosmas, J

    2014-01-01

    Medical technology has undergone major breakthroughs in recent years, especially in the area of the examination tools for diagnostic purposes. This paper reviews the swallowable capsule technology in the examination of the gastrointestinal system for various diseases. The wireless camera pill has created a more advanced method than many traditional examination methods for the diagnosis of gastrointestinal diseases such as gastroscopy by the use of an endoscope. After years of great innovation...

  4. Adhesive capsulitis. Is it possible in childhood?

    OpenAIRE

    Modesto, C. (C.); Crespo, E. (Eduardo); Villas, C. (Carlos); Aquerreta, D. (Dámaso)

    1995-01-01

    Adhesive capsulitis affecting shoulders has been extensively studied by orthopedic surgeons, but few reports have been published on this condition when it affects other joints (hips, ankles). To our knowledge no pediatric cases have been reported. As its treatment requires prolonged physiotherapy and sometimes manipulation, a correct diagnosis is essential. We would like to emphasize the importance of having this condition in mind when one is regarding a differential diagnosis, also in children.

  5. Automatic blood detection in capsule endoscopy video

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Flusser, Jan; Tachecí, I.; Sulík, L.; Bureš, J.; Krejcar, O.

    2016-01-01

    Roč. 21, č. 12 (2016), s. 1-8, č. článku 126007. ISSN 1083-3668 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985556 Keywords : Automatic blood detection * capsule endoscopy video Subject RIV: JD - Computer Applications, Robotics Impact factor: 2.530, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/flusser-0466936.pdf

  6. Constraints on oxygen fugacity within metal capsules

    Science.gov (United States)

    Faul, Ulrich H.; Cline, Christopher J., II; Berry, Andrew; Jackson, Ian; Garapić, Gordana

    2017-12-01

    Experiments were conducted with olivine encapsulated or wrapped in five different metals (Pt, Ni, Ni_{70}Fe_{30} , Fe, and Re) to determine the oxygen fugacity in the interior of large capsules used for deformation and seismic property experiments. Temperature (1200°C ), pressure (300 MPa), and duration (24 h) were chosen to represent the most common conditions in these experiments. The oxygen fugacity was determined by analysing the Fe content of initially pure Pt particles that were mixed with the olivine powder prior to the experiments. Oxygen fugacities in the more oxidizing metal containers are substantially below their respective metal-oxide buffers, with the fO_2 of sol-gel olivine in Ni about 2.5 orders of magnitude below Ni-NiO. Analysis of olivine and metal blebs reveals three different length-, and hence diffusive time scales: (1) Fe loss to the capsule over ˜ 100 μm, (2) fO_2 gradients at the sample-capsule interface up to 2 mm into the sample, and (3) constant interior fO_2 values with an ordering corresponding to the capsule material. The inferred diffusive processes are: Fe diffusion in olivine with a diffusivity ˜ 10^{-14} m^2/s , diffusion possibly of oxygen along grain boundaries with a diffusivity ˜ 10^{-12} m^2/s , and diffusion possibly involving pre-existing defects with a diffusivity ˜ 10^{-10} m^2/s . The latter, fast adjustment to changing fO_2 may consist of a rearrangement of pre-existing defects, representing a metastable equilibrium, analogous to decoration of pre-existing defects by hydrogen. Full adjustment to the external fO_2 requires atomic diffusion.

  7. Hemispherical Capsule Implosions for Fast Ignition*

    Science.gov (United States)

    Hanson, D. L.; Vesey, R. A.; Sinars, D. B.; Adams, R. G.; Cuneo, M. E.; Porter, J. L.; Slutz, S. A.; Johnston, R. R.; Wenger, D. F.; Schroen, D. G.

    2003-10-01

    The fast ignitor approach to ICF ignition separates the fuel assembly and fast heating processes. After compressing the fuel with the main driver, the fuel is ignited using a focused electron or ion beam generated by a fast, ultra-high power laser pulse. This significantly relaxes the drive symmetry, energy, and shock timing requirements compared to hot spot ignition. A hemispherical capsule target is a fast ignitor geometry well-adapted to symmetric fuel compression by a single-ended z-pinch radiation drive. The hemispherical capsule implodes radially, constrained at its equator by a flat high-density surface (a special case of the spherical capsule "cone-focus" geometry). This glide plane is mounted on a hollow pedestal that provides a plasma-free, short-pulse laser path to the compressed fuel core region. In experiments on the Z accelerator at Sandia, we are studying implosions of 2.0-mm-diameter, 60-micron-thick hemispherical capsules in cylindrical secondary hohlraums heated to 90-100 eV from one end by a 120 TW wire-array z-pinch. Analysis of ZBL 6.7 keV point-projection backlighter images of pole-hot implosions in a tall secondary and 6.18 keV monochromatic crystal backlighter images of more symmetric implosions in a short secondary will be presented. We will also discuss progress on the development of a cryogenic liquid fuel target for this fast ignitor compression geometry. * Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  8. Anterior knee pain

    Energy Technology Data Exchange (ETDEWEB)

    LLopis, Eva [Hospital de la Ribera, Alzira, Valencia (Spain) and Carretera de Corbera km 1, 46600 Alzira Valencia (Spain)]. E-mail: ellopis@hospital-ribera.com; Padron, Mario [Clinica Cemtro, Ventisquero de la Condesa no. 42, 28035 Madrid (Spain)]. E-mail: mario.padron@clinicacemtro.com

    2007-04-15

    Anterior knee pain is a common complain in all ages athletes. It may be caused by a large variety of injuries. There is a continuum of diagnoses and most of the disorders are closely related. Repeated minor trauma and overuse play an important role for the development of lesions in Hoffa's pad, extensor mechanism, lateral and medial restrain structures or cartilage surface, however usually an increase or change of activity is referred. Although the direct relation of cartilage lesions, especially chondral, and pain is a subject of debate these lesions may be responsible of early osteoarthrosis and can determine athlete's prognosis. The anatomy and biomechanics of patellofemoral joint is complex and symptoms are often unspecific. Transient patellar dislocation has MR distinct features that provide evidence of prior dislocation and rules our complication. However, anterior knee pain more often is related to overuse and repeated minor trauma. Patella and quadriceps tendon have been also implicated in anterior knee pain, as well as lateral or medial restraint structures and Hoffa's pad. US and MR are excellent tools for the diagnosis of superficial tendons, the advantage of MR is that permits to rule out other sources of intraarticular derangements. Due to the complex anatomy and biomechanic of patellofemoral joint maltracking is not fully understood; plain films and CT allow the study of malalignment, new CT and MR kinematic studies have promising results but further studies are needed. Our purpose here is to describe how imaging techniques can be helpful in precisely defining the origin of the patient's complaint and thus improve understanding and management of these injuries.

  9. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong Sun; Oh, Wan Ho; Yoo, Byung Ok; Jung, Yang Hong; Ahn, Sang Bok; Baik, Seung Je; Song, Wung Sup; Hong, Kwon Pyo

    2000-01-01

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  10. Evaluating anterior knee pain.

    Science.gov (United States)

    Hong, Engene; Kraft, Michael C

    2014-07-01

    Musculoskeletal complaints account for about 20% to 30% of all primary care office visits; of these visits, discomfort in the knee, shoulder, and back are the most prevalent musculoskeletal symptoms. Having pain or dysfunction in the front part of the knee is a common presentation and reason for a patient to see a health care provider. There are a number of pathophysiological etiologies to anterior knee pain. This article describes some of the common and less common causes, and includes sections on diagnosis and treatment for each condition as well as key points. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The anterior cingulate cortex

    Directory of Open Access Journals (Sweden)

    Pavlović D.M.

    2009-01-01

    Full Text Available The anterior cingulate cortex (ACC has a role in attention, analysis of sensory information, error recognition, problem solving, detection of novelty, behavior, emotions, social relations, cognitive control, and regulation of visceral functions. This area is active whenever the individual feels some emotions, solves a problem, or analyzes the pros and cons of an action (if it is a right decision. Analogous areas are also found in higher mammals, especially whales, and they contain spindle neurons that enable complex social interactions. Disturbance of ACC activity is found in dementias, schizophrenia, depression, the obsessive-compulsive syndrome, and other neuropsychiatric diseases.

  12. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    Science.gov (United States)

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  13. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  14. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  15. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...... the aesthetic results when orthodontic therapy itself is not feasible. This article presents integrated orthodonticrestorative solutions of anterior diastemata, associated with the conditioning of the gingival tissue with composite resin, and discusses the most relevant aspects related to their etiology...

  16. Irradiation tests of materials using HANARO instrumented capsules in 2003

    International Nuclear Information System (INIS)

    Joo, K. M.; Joe, M. S.; Oh, J. M.; Shin, Y. T.; Kang, Y. H.; Lim, I. C.; Hwang, S. R.

    2003-01-01

    The HANARO irradiation capsule system has been actively utilized for the various irradiation tests requested by users of research institutes, universities, and industries. In 2003, two instrumented capsules were designed, fabricated, and successfully irradiated at HANARO and another is under fabrication. For the evaluation of the irradiation properties of the RPV(Reactor Pressure Vessel) materials and for the development of improved evaluation technology, 02M-02K instrumented capsule was designed, fabricated, and successfully irradiated at HANARO. 02M-05U instrumented capsule was designed, fabricated, and successfully irradiated as a part of 2002 project for active utilization of HANARO. Reactor core materials were also irradiated using 02M-05U capsule. Another instrumented capsule is under design and fabrication as a part of 2003 project for active utilization of HANARO and for the development of precise temperature controlling technology

  17. Wireless communication link for capsule endoscope at 600 MHz.

    Science.gov (United States)

    Khaleghi, A; Balasingham, I

    2015-01-01

    Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.

  18. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  19. Bioengineered anterior cruciate ligament

    Science.gov (United States)

    Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor); Martin, Ivan (Inventor)

    2001-01-01

    The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the

  20. Anterior versus posterior pin placement of pelvic C-clamp in relationship to anatomical structures: a cadaver study.

    Science.gov (United States)

    Reynolds, Jason H; Attum, Basem; Acland, Robert J; Giannoudis, Peter; Roberts, Craig S

    2008-08-01

    The objective of this study was to compare anterior and posterior pin placement of the pelvic C-clamp with specific reference to the proximity of the sciatic nerve, sciatic notch, hip joint capsule, and superior gluteal neurovascular bundle. The pelvic C-clamp (Synthes, Paoli, PA) was applied to eight extracted pelvic specimens and five full cadavers (26 hips in total). Anterior and posterior pin placements were measured in relationship to the described anatomical structures. In 100% of the hips the distance from the posterior pin to the hip joint capsule was in 21 (80.8%), 23 (88.5%), and 20 (76.9%) of the hips, the anterior pin distances were greater than the posterior pin distances to the sciatic nerve, sciatic notch, and superior gluteal neurovascular bundle, respectively. Anterior pin placement is further from all anatomical structures studies with the exception of the hip joint capsule. The posterior pin was closer to the sciatic nerve, sciatic notch, and superior gluteal neurovascular bundle in all cases. Clinical decision-making for C-clamp placement should be individualised on a case-by-case basis.

  1. Changes in biomechanical properties of glenohumeral joint capsules with adhesive capsulitis by repeated capsule-preserving hydraulic distensions with saline solution and corticosteroid.

    Science.gov (United States)

    Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan

    2012-12-01

    To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  2. Capsule Shields the Function of Short Bacterial Adhesins

    OpenAIRE

    Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...

  3. Adhesive Capsulitis in 8 Dogs: Diagnosis and Management

    OpenAIRE

    Brittany Jean Carr; Sherman Orye Canapp; Debra A Canapp; Lauri-Jo Gamble; David L Dycus

    2016-01-01

    ABSTRACT:Objective: To describe clinical and diagnostic findings as well as management of adhesive capsulitis in dogs.Background: Adhesive capsulitis, also known as frozen shoulder, is a syndrome defined by loss of range of motion of the shoulder and may be the end-stage manifestation of several primary conditions.Evidentiary Value: This is a case report series of eight dogs with chronic forelimb lameness diagnosed with adhesive capsulitis.Methods: Medical records (June 1, 2010 to September...

  4. Adhesive Capsulitis in Eight Dogs: Diagnosis and Management

    OpenAIRE

    Carr, Brittany J.; Canapp, Sherman O.; Canapp, Debra A.; Gamble, Lauri-Jo; Dycus, David L.

    2016-01-01

    Objective To describe clinical and diagnostic findings as well as management of adhesive capsulitis in dogs. Background Adhesive capsulitis, also known as frozen shoulder, is a syndrome defined by loss of range of motion of the shoulder and may be the end-stage manifestation of several primary conditions. Evidentiary Value This is a case series report of eight dogs with chronic forelimb lameness diagnosed with adhesive capsulitis. Methods Medical records (June 1, 20...

  5. Production, deformation and mechanical investigation of magnetic alginate capsules

    Science.gov (United States)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  6. Encephalitozoon cuniculi causes focal anterior cataract and uveitis in dogs.

    Science.gov (United States)

    Nell, B; Csokai, J; Fuchs-Baumgartinger, A; Maaß, G

    2015-01-01

    Three mongrel dogs, aged 10 months (case 1), 14 months (case 2) and 7.5 years (case 3), were presented because of ophthalmologic disorders of 4 months, 6 months and 7 years duration, respectively. All three dogs were offspring of stray dogs from Hungary and Serbia and had positive serum antibody titres against Encephalitozoon (E.) cuniculi. The two young dogs showed unilateral, the older dog bilateral chronic anterior uveitis with posterior synechia and focal anterior cortical cataract. The fundi that could be evaluated developed focal tapetal hyporeflective lesions in the course of the disease. Dogs 1 and 2 underwent removal of the lens via phacoemulsification. PCR of the lens material was positive for E. cuniculi strains IV and II, respectively. In dog 2 findings suggestive of microsporidia were detected underneath the anterior lens capsule by immunohistochemical staining. In all cases medical treatment consisted of systemic fenbendazole, prednisolone, and topical anti-inflammatory drugs, and additional brinzolamid/timolol for dog 3. For the time being all cases (follow up 23 months, 6 months and 3 months, respectively) are still on topical anti-inflammatory therapy. It is concluded that E. cuniculi infections can cause cataract and chorioretinal lesions in dogs.

  7. Capsule irradiation tests of non-fissile materials in HANARO

    International Nuclear Information System (INIS)

    Choo, K. N.; Sohn, J. M.; Kim, B. G.; Shin, Y. T.; Oh, J. M.; Lim, I. C.; Kang, Y. H.

    2003-01-01

    The R and D programs on the nuclear reactor materials require numerous in-pile tests in HANARO. Extensive efforts have been made to establish design and manufacturing technology for the development of irradiation facilities. Material capsule and rabbit(small non-instrumented capsule) systems were developed for the irradiation test of non fissile materials in HANARO. Several irradiation capsules (8 instrumented and 2 non-instrumented capsules) and rabbits(17 rabbits) has been designed, fabricated and successfully irradiated in HANARO CT, IR, HTS or IP test holes since 1995. Capsules were designed for the irradiation of RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 3 capsules were made as a part of national projects for the promotion of HANARO utilization. Rabbits were used for the irradiation of semi-conductors(Si, Sapphire) and magnetic materials. 3,300 specimens from domestic 13 research institutes, 2 nuclear industry companies and 51 universities, were irradiated in HANARO for 26,000 hours using capsule and rabbit irradiation systems. Through this research, the nuclear characteristics of HANARO capsules and rabbits were also produced and piled up in our database

  8. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that capsule polysaccharides sterically prevent receptor-target recognition of short bacterial adhesins......Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can....... This negative interference has important biological consequences, such as affecting the ability of bacteria to form biofilms....

  9. Introduction to the physics of ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    Inertial Confinement Fusion is an approach to fusion which relies on the inertia of the fuel mass to provide confinement. To achieve conditions under which this confinement is sufficient for efficient thermonuclear burn, high gain ICF targets designed to be imploded directly by laser light. These capsules are generally a spherical shell which is filled with low density DT gas. The shell is composed of an outer region which forms the ablator and an inner region of frozen or liquid DT which forms the main fuel. Energy from the driver is delivered to the ablator which heats up and expands. As the ablator expands and blows outward, the rest of the shell is forced inward to conserve momentum. In this implosion process, several features are important. We define the in-flight-aspect-ratio (IFAR) as the ratio of the shell radius R as it implodes to its thickness ΔR. Hydrodynamic instabilities during the implosion impose limits on this ratio which results in a minimum pressure requirement of about 100 Mbar. The convergence ratio is defined as the ratio of the initial outer radius of the ablator to the final compressed radius of the hot spot. This hot spot is the central region of the compressed fuel which is required to ignite the main fuel in high gain designs. Typical convergence ratios are 30--40. To maintain a nearly spherical shape during the implosion, when convergence ratios are this large, the flux delivered to the capsule must be uniform to a few percent. The remainder of this paper discusses the conditions necessary to achieve thermonuclear ignition in these ICF capsules

  10. Effectiveness of corticosteroid injection in adhesive capsulitis.

    Science.gov (United States)

    Bal, Ajda; Eksioglu, Emel; Gulec, Berna; Aydog, Ece; Gurcay, Eda; Cakci, Aytul

    2008-06-01

    To assess whether intraarticular corticosteroids improve the outcome of a comprehensive home exercise programme in patients with adhesive capsulitis. The study was undertaken in the Physical Therapy and Rehabilitation Department of a Ministry of Health hospital in Turkey. Eighty patients with adhesive capsulitis were enrolled in the study. The patients were randomly assigned to two groups: Group 1 patients were given intraarticular corticosteroid (1 mL, 40 mg methylprednisolone acetate) followed by a 12-week comprehensive home exercise programme. Group 2 patients were given intraarticular serum physiologic (1 mL solution of 0.9% sodium chloride) followed by a 12-week comprehensive home exercise programme. The outcome parameters were Shoulder Pain and Disability Index and University of California-Los Angeles end-result scores, night pain and shoulder passive range of motion. Mean actual changes in abduction range of motion, Shoulder Pain and Disability Index-total score and Shoulder Pain and Disability Index-pain score were statistically different between the two groups at the second week, with the better scores determined in group 1. However, there were no significant differences between the groups at the 12th week. Medians of University of California-Los Angeles scores in the second week were significantly different between the two groups (P = 0.02), with better scores in group 1; however, the difference in 12th week scores was insignificant. Intraarticular corticosteroids have the additive effect of providing rapid pain relief, mainly in the first weeks of the exercise treatment period. In patients with adhesive capsulitis who have pain symptom predominantly, intraarticular corticosteroid therapy could be advised concomitantly with exercise.

  11. Campylobacter polysaccharide capsules: virulence and vaccines

    Directory of Open Access Journals (Sweden)

    Patricia eGuerry

    2012-02-01

    Full Text Available Campylobacter jejuni remains a major cause of bacterial diarrhea worldwide and is associated with numerous sequelae, including Guillain Barre Syndrome, inflammatory bowel disease, reactive arthritis, and irritable bowel syndrome. C. jejuni is unusual for an intestinal pathogen in its ability to coat its surface with a polysaccharide capsule (CPS. These capsular polysaccharides vary in sugar composition and linkage, especially those involving heptoses of unusual configuration and O-methyl phosphoramidate linkages. This structural diversity is consistent with CPS being the major serodeterminant of the Penner scheme, of which there are 47 C. jejuni serotypes. Both CPS expression and expression of modifications are subject to phase variation by slip strand mismatch repair. Although capsules are virulence factors for other pathogens, the role of CPS in C. jejuni disease has not been well defined beyond descriptive studies demonstrating a role in serum resistance and for diarrhea in a ferret model of disease. However, perhaps the most compelling evidence for a role in pathogenesis are data that CPS conjugate vaccines protect against diarrheal disease in non-human primates. A CPS conjugate vaccine approach against this pathogen is intriguing, but several questions need to be addressed, including the valency of CPS types required for an effective vaccine. There have been numerous studies of prevalence of CPS serotypes in the developed world, but few studies from developing countries where the disease incidence is higher. The complexity and cost of Penner serotyping has limited its usefulness, and a recently developed multiplex PCR method for determination of capsule type offers the potential of a more rapid and affordable method. Comparative studies have shown a strong correlation of the two methods and studies are beginning to ascertain CPS-type distribution worldwide, as well as examination of correlation of severity of illness with specific CPS types.

  12. Chromoendoscopy in magnetically guided capsule endoscopy

    Science.gov (United States)

    2013-01-01

    Background Diagnosis of intestinal metaplasia and dysplasia via conventional endoscopy is characterized by low interobserver agreement and poor correlation with histopathologic findings. Chromoendoscopy significantly enhances the visibility of mucosa irregularities, like metaplasia and dysplasia mucosa. Magnetically guided capsule endoscopy (MGCE) offers an alternative technology for upper GI examination. We expect the difficulties of diagnosis of neoplasm in conventional endoscopy to transfer to MGCE. Thus, we aim to chart a path for the application of chromoendoscopy on MGCE via an ex-vivo animal study. Methods We propose a modified preparation protocol which adds a staining step to the existing MGCE preparation protocol. An optimal staining concentration is quantitatively determined for different stain types and pathologies. To that end 190 pig stomach tissue samples with and without lesion imitations were stained with different dye concentrations. Quantitative visual criteria are introduced to measure the quality of the staining with respect to mucosa and lesion visibility. Thusly determined optimal concentrations are tested in an ex-vivo pig stomach experiment under magnetic guidance of an endoscopic capsule with the modified protocol. Results We found that the proposed protocol modification does not impact the visibility in the stomach or steerability of the endoscopy capsule. An average optimal staining concentration for the proposed protocol was found at 0.4% for Methylene blue and Indigo carmine. The lesion visibility is improved using the previously obtained optimal dye concentration. Conclusions We conclude that chromoendoscopy may be applied in MGCE and improves mucosa and lesion visibility. Systematic evaluation provides important information on appropriate staining concentration. However, further animal and human in-vivo studies are necessary. PMID:23758801

  13. Postirradiation examination of capsule GF-4. [HTGR

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, W.J.; Sedlak, B.J.

    1980-10-01

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC/sub 2/ and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO/sub 2/ fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted.

  14. Postirradiation examination of capsule GF-4

    International Nuclear Information System (INIS)

    Kovacs, W.J.; Sedlak, B.J.

    1980-10-01

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC 2 and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO 2 fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted

  15. C5 capsule operation modes analysis

    International Nuclear Information System (INIS)

    Negut, Gh.; Ancuta, Mirela; Stefan, Violeta

    2008-01-01

    This paper is part of the Nuclear Research Institute Program 13 dedicated to 'TRIGA Research Reactor performance enhancing' and its objective is improving the engineering of the structural materials irradiation. The paper raises the knowledge level on C5 capsule irradiation modes and utilizes previous results in order to increase C5 performances. In the paper the irradiation modes to test zirconium yttrium sample are assessed. These tests are proposed by AECL. There are presented the C5 initial conditions and models. Also. there are presented the thermal hydraulic conditions during normal and accidental operation. The results will be used in the C5 safety report. (authors)

  16. Characterization of an aged WESF capsule

    International Nuclear Information System (INIS)

    Kenna, B.T.; Schultz, F.J.

    1983-07-01

    A joint effort by SNLA and ORNL was initiated for a detailed characterization of an 18-year-old WESF 137 Cs source which has been used in the Sandia Irradiator for Dried Sewage Solids. The study included evaluation of the inner and outer stainless steel capsules by optical metallography, electron microprobe, and physical testing. Analysis of the residual atmospheres within the two containers was also done. The CsCl was analyzed for isotopic content and impurities. No potential problem areas, including corrosion, were found

  17. Automatic blood detection in capsule endoscopy video

    Science.gov (United States)

    Novozámský, Adam; Flusser, Jan; Tachecí, Ilja; Sulík, Lukáš; Bureš, Jan; Krejcar, Ondřej

    2016-12-01

    We propose two automatic methods for detecting bleeding in wireless capsule endoscopy videos of the small intestine. The first one uses solely the color information, whereas the second one incorporates the assumptions about the blood spot shape and size. The original idea is namely the definition of a new color space that provides good separability of blood pixels and intestinal wall. Both methods can be applied either individually or their results can be fused together for the final decision. We evaluate their individual performance and various fusion rules on real data, manually annotated by an endoscopist.

  18. Reducing redundancy in wireless capsule endoscopy videos.

    Science.gov (United States)

    Lee, Hyun-Gyu; Choi, Min-Kook; Shin, Byeong-Seok; Lee, Sang-Chul

    2013-07-01

    We eliminate similar frames from a wireless capsule endoscopy video of the human intestines to maximize spatial coverage and minimize the redundancy in images. We combine an intensity correction method with a method based an optical flow and features to detect and reduce near-duplicate images acquired during the repetitive backward and forward egomotions due to peristalsis. In experiments, this technique reduced duplicate image of 52.3% from images of the small intestine. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  19. Inestabilidad Anterior de Hombro

    Directory of Open Access Journals (Sweden)

    Pablo David Flint Kuran

    2013-11-01

    Full Text Available In­tro­duc­ción La luxación recidivante de hombro es una patología frecuente en pacientes jóvenes, laboralmente activos. Existen numerosas técnicas quirúrgicas para la inestabilidad glenohumeral. La técnica de Bristow, discutida por no ser anatómica y por sus complicaciones, continúa vigente debido al bajo índice de reluxaciones. Los objetivos fueron determinar el índice de recidiva, alteraciones funcionales e índice de consolidación del injerto. Materiales­ y­ Métodos Se evaluaron 24 pacientes del sexo masculino, de entre 19 y 40 años, operados por luxación anterior recidivante de hombro según la técnica de Bristow, entre enero de 2003 y agosto de 2011. Se evaluó la tasa de reluxación, la función articular según el puntaje de Constant y el posicionamiento del injerto con respecto a la superficie articular con tomografía y radiografías para evaluar la consolidación del injerto. Se registraron las complicaciones quirúrgicas. Resultados ­Todos los pacientes eran hombres, con rango de edad de 19 a 40 años. La causa fue traumática en 24 pacientes. Dieciséis pacientes presentaron más de 3 episodios de luxación prequirúrgicos. Según la escala de Constant, 21 obtuvieron entre 96 y 100 puntos, y los restantes, entre 90 y 95 puntos. No hubo nuevos episodios de luxaciones. La tomografía mostró la consolidación en todos los casos. Un paciente tuvo una imagen osteolítica alrededor del tornillo, sin compromiso funcional del hombro. Conclusión La técnica de Bristow para tratar la luxación anterior recidivante de hombro provocó un bajo índice de complicaciones, con resultados funcionales entre excelentes y buenos. No hubo episodios de reluxación y se logró la consolidación del injerto óseo en todos los casos.

  20. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  1. TREATMENT PROTOCOLS OF ADHESIVE CAPSULITIS - METANALYSIS

    Directory of Open Access Journals (Sweden)

    Alisson Guimbala dos Santos Araujo

    2013-04-01

    Full Text Available Introduction: The adhesive capsulitis (AC is an idiopathic disorder that affects about 3-5% of the general population, the majority being aged 50 years. It is divided into three stages: acute or hiperálgica, rigidity phase or stage of freezing and thawing. This study aimed to analyze the protocols of treatments for adhesive capsulitis. Methods: We performed literature search in electronic databases, BIREME, SciELO, LILACS and PubMed. We analyzed 20 articles of which seven met the inclusion criteria of this study. Results: Of the 20 articles analyzed, it was found that only seven had controlled clinical trials, and the articles selected for the treatment of AC were: medication and physiotherapy, manipulation, hydraulic distension, serials suprascapular nerve blocks, acupuncture, exercise, physiotherapy and nonsteroidal anti-inflammatory therapy dynasplint, deep friction massage and wave diathermy. Conclusion: As noted in the studies, there is a range of treatments that have proven effective for AC, failing to come to a conclusion of what would be the most appropriate treatment. However it was noted that physiotherapy through kinesiotherapy remains the best option, and the earlier therapeutic intervention performed, the better the results.

  2. Corticosteroid Injections for Adhesive Capsulitis: A Review.

    Science.gov (United States)

    Xiao, Ryan C; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J

    2017-05-01

    Adhesive capsulitis is a self-limiting condition in a majority of patients and is often treated nonoperatively. However, symptoms may take 2 to 3 years to resolve fully. A small, but significant, portion of patients require surgical intervention. The purpose of this systematic review is to evaluate the efficacy of corticosteroid injections for the treatment of adhesive capsulitis (AC). A review of articles indexed by the United States National Library of Medicine was conducted by querying the PubMed database for studies involving participants with AC, frozen shoulder, stiff shoulder, or painful shoulder. Articles that included corticosteroids, glucocorticoids, steroids, and injections were included. Corticosteroid injections provide significant symptom relief for 2 to 24 weeks. Injections can be performed intra-articularly or into the subacromial space. Evidence suggests that a 20 mg dose of triamcinolone may be as effective as a 40 mg injection. It remains unclear whether image-guided injections produce a clinically significant difference in outcomes when compared with landmark-guided (blind) injections. Corticosteroids may be less beneficial for diabetic patients. Patients using protease inhibitors (antiretroviral therapy) should not receive triamcinolone because the drug-drug interaction may result in iatrogenic Cushing syndrome. Corticosteroid injections for AC demonstrate short-term efficacy, but may not provide a long-term benefit. More high quality, prospective studies are needed to determine whether corticosteroid injections using ultrasound guidance significantly improve outcomes.

  3. Isotretinoin Oil-Based Capsule Formulation Optimization

    Directory of Open Access Journals (Sweden)

    Pi-Ju Tsai

    2013-01-01

    Full Text Available The purpose of this study was to develop and optimize an isotretinoin oil-based capsule with specific dissolution pattern. A three-factor-constrained mixture design was used to prepare the systemic model formulations. The independent factors were the components of oil-based capsule including beeswax (X1, hydrogenated coconut oil (X2, and soybean oil (X3. The drug release percentages at 10, 30, 60, and 90 min were selected as responses. The effect of formulation factors including that on responses was inspected by using response surface methodology (RSM. Multiple-response optimization was performed to search for the appropriate formulation with specific release pattern. It was found that the interaction effect of these formulation factors (X1X2, X1X3, and X2X3 showed more potential influence than that of the main factors (X1, X2, and X3. An optimal predicted formulation with Y10 min, Y30 min, Y60 min, and Y90 min release values of 12.3%, 36.7%, 73.6%, and 92.7% at X1, X2, and X3 of 5.75, 15.37, and 78.88, respectively, was developed. The new formulation was prepared and performed by the dissolution test. The similarity factor f2 was 54.8, indicating that the dissolution pattern of the new optimized formulation showed equivalence to the predicted profile.

  4. Petrous bone fractures violating otic capsule.

    Science.gov (United States)

    Magliulo, Giuseppe; Ciniglio Appiani, Mario; Iannella, Giannicola; Artico, Marco

    2012-12-01

    This study presents our experience with a series of patients suffering from petrous bone fractures violating the otic capsule who underwent subtotal petrosectomy combined with eustachian tube, middle ear, and mastoid obliteration, with the goal of preventing cerebrospinal fluid (CSF) leak and meningitis. This study enrolled 26 patients between 1997 and 2011. The clinical symptoms, otoscopy, and preoperative and postoperative audiometry and facial function, as well as CSF leak or meningitis, were evaluated in each patient. The entire group underwent a subtotal petrosectomy using the technique described in detail by Fisch. In addition, each patient was interviewed using a questionnaire to evaluate the impact on quality of life. Intraoperatively, we found significant CSF leaks in 14 patients (42.5%). No patient reported other episodes of CSF leak or meningitis after the surgery. The patients' responses of facial nerve function were slightly worse than the House-Brackmann evaluation (50% versus 42.3%; p < 0.05). The vast majority (88.5%) of the patients experienced no social impact. Our findings suggest the importance of not underestimating the risk for CSF leak in the petrous bone fractures violating the otic capsule. Preoperative counseling regarding the various troublesome complications must adequately motivate candidates to undergo surgery by pointing out the positive impact of the proposed treatment.

  5. Potential value of Cs-137 capsules

    International Nuclear Information System (INIS)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions

  6. Quality evaluation of simvastatin compounded capsules

    Directory of Open Access Journals (Sweden)

    Flávia Dias Marques-Marinho

    2011-09-01

    Full Text Available Simvastatin is commercially available as tablets and compounded capsules in Brazil. Very few reports regarding these capsules' quality, and consequently their efficacy, are available. The pharmaceutical quality of 30 batches of 20 mg simvastatin capsules from the market was evaluated by weight determination, content uniformity, disintegration (Brazilian Pharmacopeia, assay and dissolution test (USP32 tablet monograph. A HPLC method was developed for assay, content uniformity and dissolution test, and specifications were also established. Out of the 30 batches evaluated, 29 showed capsule disintegration within 45 min and individual weight variation was within ±10% or ±7.5% relative to average weight, for 300 mg, respectively. Only 27 batches met dissolution test criteria with values >80% of the labeled amount in 45 min; 21 batches showed simvastatin content between 90.0-110.0% of the labeled amount and 19 batches had at least 9 out of 10 capsules with content uniformity values between 85.0-115.0% of the labeled amount with RSDNo Brasil, a sinvastatina está comercialmente disponível na forma de comprimidos e cápsulas manipuladas. Poucos relatos estão disponíveis sobre a qualidade e, consequentemente, a eficácia dessas cápsulas. A qualidade de 30 lotes de sinvastatina 20 mg cápsulas do mercado foi avaliada através da determinação de peso, uniformidade de conteúdo, desintegração (Farmacopéia Brasileira, doseamento e teste de dissolução (monografia comprimidos USP32. Método por CLAE foi desenvolvido para o doseamento, uniformidade de conteúdo e teste de dissolução; além disso, especificações foram estabelecidas. Dos 30 lotes avaliados, 29 apresentaram desintegração da cápsula até 45 min e a variação do peso individual foi ± 10% ou ± 7,5% em relação ao peso médio, se 300 mg, respectivamente. Apenas 27 lotes preencheram os critérios do teste de dissolução com valores > 80% da quantidade rotulada, em 45 min, 21

  7. Anterior ankle arthrodesis

    Science.gov (United States)

    Slater, Gordon L; Sayres, Stephanie C; O’Malley, Martin J

    2014-01-01

    Ankle arthrodesis is a common procedure that resolves many conditions of the foot and ankle; however, complications following this procedure are often reported and vary depending on the fixation technique. Various techniques have been described in the attempt to achieve ankle arthrodesis and there is much debate as to the efficiency of each one. This study aims to evaluate the efficiency of anterior plating in ankle arthrodesis using customised and Synthes TomoFix plates. We present the outcomes of 28 ankle arthrodeses between 2005 and 2012, specifically examining rate of union, patient-reported outcomes scores, and complications. All 28 patients achieved radiographic union at an average of 36 wk; the majority of patients (92.86%) at or before 16 wk, the exceptions being two patients with Charcot joints who were noted to have bony union at a three year review. Patient-reported outcomes scores significantly increased (P plate offers added compression and provides a rigid fixation for arthrodesis stabilization. PMID:24649408

  8. 21 CFR 520.1920 - Prochlorperazine, isopropamide sustained release capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Prochlorperazine, isopropamide sustained release capsules. 520.1920 Section 520.1920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... dogs in which gastrointestinal disturbances are associated with emotional stress. (2)(i) Capsules...

  9. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the Chinese silver carp, Hypophthalmichthys molitrix (Val.). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  10. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the chinese silver carp,. Hypophthalmichthys molitrix (VaL). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  11. Evidence for an intact polysaccharide capsule in Bordetella pertussis.

    Science.gov (United States)

    Neo, YiLin; Li, Rui; Howe, Josephine; Hoo, Regina; Pant, Aakanksha; Ho, SiYing; Alonso, Sylvie

    2010-03-01

    Polysaccharide capsules contribute to the pathogenesis of many bacteria species by providing resistance against various defense mechanisms. The production of a capsule in Bordetella pertussis, the etiologic agent of whooping cough, has remained controversial; earlier studies reported this pathogen as a capsulated microorganism whereas the recent B. pertussis genome analysis revealed the presence of a truncated capsule locus. In this work, using transmission electron microscopy and immunostaining approaches, we provide a formal evidence for the presence of an intact microcapsule produced at the surface of both laboratory strain and clinical isolates of B. pertussis. In agreement with previous studies, we found that the capsule is optimally produced in avirulent phase. Unexpectedly, the presence of the capsule was also detected at the surface of virulent B. pertussis bacteria. Consistently, a substantial transcriptional activity of the capsule operon was detected in virulent phase, suggesting that the capsular polysaccharide may play a role during pertussis pathogenesis. In vitro assays indicated that the presence of the capsule does not affect B. pertussis adherence to mammalian cells and does not further protect the bacterium from phagocytosis, complement-mediated killing or antimicrobial peptide attack. Copyright 2009. Published by Elsevier SAS.

  12. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  13. Diamagnetically stabilized levitation control of an intraluminal magnetic capsule

    International Nuclear Information System (INIS)

    Lam, Michael; Mintchev, Martin

    2009-01-01

    Controlled navigation promotes full utilization of capsule endoscopy for reliable real-time diagnosis in the gastrointestinal (GI) tract, but intermittent natural peristalsis can disturb the navigational control, destabilize the capsule and take it out of levitation. The focus of the present work was to develop an economical and effective real-time magnetic capsule-guiding system that can operate in the presence of naturally existing peristalsis while retaining navigational control. A real-size magnetic navigation system that can handle peristaltic forces of up to 1.5 N was designed utilizing the computer-aided design (CAD) system Maxwell 3D (Ansoft, Pittsburg, PA) and was verified using a small-size physical experimental setup. The proposed system contains a pair of 50 cm diameter, 10 000-turn copper electromagnets with a 10 cm × 10 cm ferrous core driven by currents of up to 300 A and can successfully maintain position control over the levitating capsule during peristalsis. The addition of bismuth diamagnetic casing for stabilizing the levitating capsule was also studied. A modeled magnetic field around the diamagnetically cased permanent magnet was shown to be redistributed aligning its interaction with the external electromagnets, thus stabilizing the levitating capsule. In summary, a custom-designed diamagnetically facilitated capsule navigation system can successfully steer an intraluminal magnet-carrying capsule

  14. Material properties of the human posterior knee capsule

    NARCIS (Netherlands)

    Rachmat, H. H.; Janssen, D.; Verkerke, G. J.; Diercks, R. L.; Verdonschot, N.

    2015-01-01

    BACKGROUND: There is considerable interest to develop accurate subject-specific biomechanical models of the knee. Most of the existing models currently do not include a representation of the posterior knee capsule. In order to incorporate the posterior capsule in knee models, data is needed on its

  15. Material properties of the human posterior knee capsule

    NARCIS (Netherlands)

    Rachmat, H.H.; Janssen, D.W.; van Tienen, T.; Diercks, R.L.; Verkerke, Gijsbertus Jacob; Verdonschot, Nicolaas Jacobus Joseph; Fernandes, Paulo; Folgado, Joao; Silva, Miguel

    2012-01-01

    BACKGROUND: There is considerable interest to develop accurate subject-specific biomechanical models of the knee. Most of the existing models currently do not include a representation of the posterior knee capsule. In order to incorporate the posterior capsule in knee models, data is needed on its

  16. Iodometric determination of ampicillin in proprietary capsules | Ejele ...

    African Journals Online (AJOL)

    The concentration of ampicillin in ampicillin capsule preparations purchased in Owerri main market, Imo State of Nigeria, was determined using the iodometric titration method. The results showed that the ampicillin concentrations in the capsules contained between 250 and 260 mg/cap of ampicillin trihydrate. Statistical ...

  17. Langmuir and Langmuir–Blodgett films of capsules of haemoglobin ...

    Indian Academy of Sciences (India)

    Haemoglobin; capsules; Langmuir–Blodgett films; pH; multi-walled capsules; isoelectric point. 1. Introduction. Drug delivery and storage of formulations in pharma- ceutical applications require microencapsulation tech- niques. Many different methods have been used to develop encapsulation techniques for the purpose of.

  18. Pharmacokinetic Study of a Capsule-based Chronomodulated Drug ...

    African Journals Online (AJOL)

    Purpose: To develop and determine the in vivo performance of a capsule-based pulsatile drug delivery system containing salbutamol sulphate. Methods: A controlled pulsatile release of drug after a programmed 4 h lag period was achieved from cross-linked gelatin capsule shells containing salbutamol pellets, and sealed ...

  19. Clinical effect of Resina Draconis capsules on primary dysmenorrhoea

    African Journals Online (AJOL)

    Clinical effect of Resina Draconis capsules on primary dysmenorrhoea. Li Sun, Jia Wang. Abstract. Purpose: To examine the effectiveness of Resina Draconis capsules in the treatment of primary dysmenorrhoea. Methods: In total, 324 patients with primary dysmenorrhoea were randomly allocated to three groups based on ...

  20. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy.

    Science.gov (United States)

    Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N

    2008-05-01

    Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.

  1. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  2. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Almeida, J.R.F. de.

    1983-01-01

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32 P from the capsule in water, with and without water flow. The desorption of residual 32 P was analysed by isotopic exchange with 31 P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32 P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31 P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author) [pt

  3. [Wireless capsule endoscopy: basic principles and clinical utility].

    Science.gov (United States)

    González-Suárez, Begoña; Galter, Sara; Balanzó, Joaquín

    2007-06-01

    Wireless capsule endoscopy (PillCam) represents a major advance in the study of small bowel disease since this procedure allows images of hitherto unreachable areas to be obtained. Approved for use by the Food and Drug Administration in August 2000, capsule endoscopy is currently a first line procedure in the study of small bowel disease. This technique consists of a non-reusable swallowable capsule (length 26 x 11 mm) that acquires video images while moving through the gastrointestinal tract propelled by natural peristalsis. The main indications of capsule endoscopy are evaluation of obscure gastrointestinal bleeding, chronic anemia, and inflammatory bowel disease. Contraindications are swallowing disorders and known or suspected small bowel strictures of any etiology. Consequently, small bowel follow through is useful prior to capsule endoscopy when these lesions are suspected.

  4. Multi-modal imaging of adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Zappia, Marcello; Di Pietto, Francesco; Aliprandi, Alberto; Pozza, Simona; De Petro, Paola; Muda, Alessandro; Sconfienza, Luca Maria

    2016-06-01

    Adhesive capsulitis of the shoulder is a clinical condition characterized by progressive limitation of active and passive mobility of the glenohumeral joint, generally associated with high levels of pain. Although the diagnosis of adhesive capsulitis is based mainly on clinical examination, different imaging modalities including arthrography, ultrasound, magnetic resonance, and magnetic resonance arthrography may help to confirm the diagnosis, detecting a number of findings such as capsular and coracohumeral ligament thickening, poor capsular distension, extracapsular contrast leakage, and synovial hypertrophy and scar tissue formation at the rotator interval. Ultrasound can also be used to guide intra- and periarticular procedures for treating patients with adhesive capsulitis. • Diagnosis of adhesive capsulitis is mainly based on clinical findings. • Imaging may be used to exclude articular or rotator cuff pathology. • Thickening of coracohumeral and inferior glenohumeral ligaments are common findings. • Rotator interval fat pad obliteration has 100 % specificity for adhesive capsulitis. • Ultrasound can be used to guide intra- and periarticular treatments.

  5. Intra-articular injection of hyaluronate versus corticosteroid in adhesive capsulitis.

    Science.gov (United States)

    Lim, Tae Kang; Koh, Kyoung Hwan; Shon, Min Soo; Lee, Seung Won; Park, Young Eun; Yoo, Jae Chul

    2014-10-01

    The goal of this study was to prospectively compare the early clinical results of intra-articular injection of hyaluronate or corticosteroid in patients with idiopathic adhesive capsulitis. The authors' hypothesis was that there would be no difference between groups. Sixty-eight patients with idiopathic adhesive capsulitis were equally randomized to receive either corticosteroid or hyaluronate injection. All patients underwent standard physical examination and magnetic resonance imaging. Intra-articular injection was performed through an anterior approach by the same orthopedic surgeon without image guidance. Patients were followed up 2 and 12 weeks after completion of the injection. The primary outcome was the Constant score at week 12. Secondary outcomes included the visual analog scale (VAS) pain score, the American Shoulder and Elbow Surgeons (ASES) score, and range of motion at each time point. No significant differences were noted in preoperative demographic features or baseline shoulder function between groups. After treatment, no significant differences were noted in early clinical outcomes (at weeks 2 and 12) with VAS, ASES, and Constant scores between groups (all P>.05). Evaluation of range of motion showed no difference in forward elevation or external rotation at each time point. Internal rotation was significantly lower at week 2 in the hyaluronate group compared with the corticosteroid group (P=.015). Internal rotation improved at week 12, with no significant difference between groups. Patients treated with intra-articular injection of hyaluronate and corticosteroid for idiopathic adhesive capsulitis showed significant improvement in early clinical scores and range of motion without significant differences between groups. Copyright 2014, SLACK Incorporated.

  6. Integrated Diagnostic Analysis of ICF Capsule Performance

    Science.gov (United States)

    Cerjan, Charles

    2012-10-01

    An understanding of the dynamics of imploding Inertial Confinement Fusion (ICF) capsules is crucial to achieve high convergence and gain. The relative roles of laser irradiation, hohlraum drive, and capsule response are intertwined and will be difficult to disentangle unless appropriate diagnostic probes are fielded and their results correlated. In the case of capsule implosions, several currently deployed diagnostics provide important information about the size and shape of the developing hot spot through x-ray self-emission, neutron production and average ion temperature by neutron time-of-flight signals, shell material mix into the hot spot by high-resolution x-ray spectra, and remaining mass during convergent ablation by x-ray backlighting. Obtaining a physically consistent picture of the implosion dynamics requires an integration of these disparate experimental data. This talk describes a three-dimensional model that attempts this integration. Assuming pressure equilibrium at peak compression and invoking simple radiative and equation-of-state relations, the pressure, density and electron temperature are obtained by optimized fitting of the experimental output to simple, global functional forms. The fitting procedure is sufficiently flexible to incorporate typical observational data such as x-ray self-emission, neutron time-of-flight signals, neutron yield, high-resolution x-ray spectra and radiographic images. Once consistency is obtained, many important secondary quantities can be derived such as the fuel areal density, high energy x-ray emission, neutron images, and nuclear activation. This approach has been validated by comparison with radiation-hydrodynamic simulations, producing semi-quantitative agreement and is now routinely used to characterize cryogenic implosion experiments. This talk will provide an overview of the implementation of the model and describe its application to recent experimental data.[4pt] In addition to my collaborators Paul

  7. Conventional MRI Finding in a Case of Adhesive Shoulder Capsulitis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hak Hoon [Yeosu Hanyeoexpo Hospital, Yeosu (Korea, Republic of); Back, Chang Hee [Yeosu Baek Hospital, Yeosu (Korea, Republic of)

    2010-02-15

    To evaluate the conventional magnetic resonance image findings in patients with adhesive shoulder capsulitis. The preoperative MR images of 76 patients with adhesive shoulder capsulitis that was also treated by arthroscopic capsule release. In contrast to the MR images of 25 control patients without adhesive shoulder capsulitis, the thickness and area of hyposignal intensity around the coracohumeral ligament (CHL), subcoracoidal fat, capsular thickness of the rotator interval, capsular thickness, and height of the axillary recess were measured. The existence of fluid in the axillary recess was also verified. Patients with adhesive capsulitis showed a significant increase in the thickness (average 10.57 mm vs. 5.88 mm, T=8.289, p<0.001), area (average 3.49 point vs. 0.96 point Z=7.775, p< 0.001) of hyposignal intensity around CHL, and a thickened joint capsule in the rotator interval (average 5.93 mm vs. 2.15 mm, Z=6.472, p< 0.001). The thickness of the hyposignal intensity around the CHL is about 10 mm or more and has a specificity of 96%, a sensitivity of about 55% in the area of hyposignal intensity from around the CHL, Seventy-five percent or more of cases, showed a 100%, 95%, complete obliteration of the subcoracoidal fat that was 96%, and a 50% thickness of the capsule. A rotator interval of 6mm or more had a 96%, 50% for the diagnosis of adhesive capsulitis of the shoulder. The capsular thickness and maximal height of axillary recess and the presence of fluid in the axillary recess was not significant in patients with adhesive shoulder capsulitis. Thickening of the hyposignal intensity around the CHL, subcoracoidal fat obliteration, and capsular thickening at the rotator interval, are characteristic MRI findings in adhesive shoulder capsulitis

  8. Anterior segment indocyanine green angiography in anterior scleritis and episcleritis.

    Science.gov (United States)

    Guex-Crosier, Yan; Durig, Jacques

    2003-09-01

    To evaluate the pattern of anterior segment indocyanine green (ICG) angiography in episcleritis and scleritis. Prospective comparative (paired-eye) observational case series. Twenty subjects presenting clinical diseases compatible with episcleritis or scleritis. Anterior segment ICG angiography was performed according to a standard protocol in subjects presenting either episcleritis or scleritis. Photographs of the anterior segment were taken in the early phase (up to 3 minutes after dye injection), intermediate phase (10-12 minutes) and late phase (30-45 minutes). The inflamed zones were compared with the same regions of the controlateral eye. The amount of protein ICG exudation was scored by a masked observer as follows: zero for no exudation, one for slight exudation, two for moderate exudation, and three for severe exudation. Evaluation of dye leakage, which reflects protein exudation, with anterior segment ICG angiography in episcleritis and scleritis. Twenty subjects with a mean age of 43 +/- 15 years (7 male, 13 female) were enrolled in the study. Thirteen subjects had anterior scleritis (7 nodular, 5 diffuse, and 1 scleromalacia perforans), and 7 subjects had episcleritis. Only 1 out of 7 subjects with episcleritis showed a slight ICG leakage (a score of one), whereas all subjects with scleritis had ICG leakage scores of one or more (P = 0.0005, Fisher exact test). ICG angiography of the anterior segment of the eye is a good clinical test to differentiate episcleritis from scleritis.

  9. Electromagnetic Control System for Capsule Navigation: Novel Concept for Magnetic Capsule Maneuvering and Preliminary Study.

    Science.gov (United States)

    Lucarini, Gioia; Mura, Marco; Ciuti, Gastone; Rizzo, Rocco; Menciassi, Arianna

    The gastrointestinal tract is home of some of the most deadly human diseases. The main problems are related to the difficulty of accessing it for diagnosis or intervention and concomitant patient discomfort. The flexible endoscopy technique has established itself in medical practice due to its high diagnostic accuracy and reliability; however, several technical limitations still remain and the procedure is poorly tolerated by patients. The use of magnetic fields to control and steer endoscopic capsules is increasing in minimally invasive procedures. In fact, magnetic coupling is one of the few physical phenomena capable of transmitting motion beyond a physical barrier, allowing for the compact design of the device itself. In this framework, the authors present the preliminary design and assessment of a magnetic coupling for magnetic endoscopic capsules considering an electromagnetic approach. In particular, a novel toroidal electromagnet is proposed as the control and driving system. The system concept, design, and preliminary results are reported.

  10. Photophysics Applied to Cavitands and Capsules.

    Science.gov (United States)

    Berryman, Orion B; Dube, Henry; Rebek, Julius

    2011-07-01

    The use of light as a stimulus to control functional materials or nano-devices is appealing as it provides convenient control of triggering events where and when they are desired without introducing extra components to the system. Many photophysical and photochemical processes are extremely fast, giving rise to nearly instantaneous onset of events. However, these fast processes can be challenging to engineer into chemical systems. Supramolecular chemistry offers a convenient way to study and control photoprocesses. Given the reversible and self-programmed nature of modern host-guest systems, a modular approach can be considered in which different photoprocesses are coupled to obtain complex functions that emerge and are controlled solely by light inputs. In this review, we highlight recent examples of photoswitching and photophysics applied in the context of supramolecular host-guest systems, with a particular emphasis on resorcinarene based cavitands and hydrogen bonded capsules.

  11. Multilevel wireless capsule endoscopy video segmentation

    Science.gov (United States)

    Hwang, Sae; Celebi, M. Emre

    2010-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. WCE transmits more than 50,000 video frames per examination and the visual inspection of the resulting video is a highly time-consuming task even for the experienced gastroenterologist. Typically, a medical clinician spends one or two hours to analyze a WCE video. To reduce the assessment time, it is critical to develop a technique to automatically discriminate digestive organs and shots each of which consists of the same or similar shots. In this paper a multi-level WCE video segmentation methodology is presented to reduce the examination time.

  12. Capsule HRB-15B postirradiation examination report

    Energy Technology Data Exchange (ETDEWEB)

    Ketterer, J.W.; Bullock, R.E.

    1981-06-01

    Capsule HRB-15B design tested 184 thin graphite trays containing unbonded fuel particles to peak exposures of 6.6 x 10/sup 25/ n/m/sup 2/ (E > 29 fJ)/sub HTGR/ fast fluence, approx. 27% fissions per initial metal atom (FIMA) fissile burnup, and 6% FIMA fertile burnup at nominal time-averaged temperatures of 815 to 915/sup 0/C. The capsule tested a variety of low-enriched uranium (approx. 19.5% U-235) fissile particle types, including UC/sub 2/, UC/sub x/O/sub y/, UO/sub 2/, zirconium-buffered UO/sub 2/ (referred to in this report as UO/sub 2//sup *), and 1:1(Th,U)O/sub 2/ with both TRISO and silicon-BISO coatings. All fertile particles were ThO/sub 2/ with BISO, silicon-BISO, or TRISO coatings. The findings indicated that all TRISO particles retained virtually all of their fission product inventories, except small quantities of silver, at these irradiation temperatures, while some of the silicon-BISO particles released significant amounts of both silver and cesium. No kernel migration, pressure vessel, or outer pyrolytic carbon (OPyC) failures were observed in the fuel particles, which had total diameters of < 900 ..mu..m; however, the incidence of failed OPyC coatings was found to increase with particle size in the TRISO inert particles, which had diameters of 1000 to 1200 ..mu..m. UO/sub 2//sup */ particles exhibited no detrimental irradiation effects, but they contained pure carbon precipitates in the kernels after irradiation which were not observed in the undoped UO/sub 2/ particles. Postirradiation examination revealed no differences in the irradiation performance of three UC/sub x/O/sub y/ kernel types with varying oxygen/uranium ratios.

  13. Anterior Knee Pain (Chondromalacia Patellae).

    Science.gov (United States)

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  14. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Towers, J.D.; Golla, S.

    2001-01-01

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  15. Adhesion and detachment of a capsule in axisymmetric flow

    Science.gov (United States)

    Keh, M. P.; Leal, L. G.

    2016-05-01

    The adhesion and detachment of a capsule on a solid boundary surface is studied via a combination of scaling theory and numerical simulation and the behavior is compared and contrasted with a vesicle. It is shown that the dominant physical property for both capsules and vesicles is the area dilation modulus Ks of the membrane. The nonzero shear modulus Gs for capsules increases the resistance to deformation and thus decreases slightly the equilibrium contact radius for an adhered capsule compared to an adhered vesicle. The detachment process in this study is due to an external axisymmetric flow. Unlike a rigid body that must be pulled away without change of shape, capsules (and vesicles) almost always detach dominantly by peeling in which the contact radius decreases but the minimum separation distance does not change until the final moments of detachment. Compared to a vesicle with the same Ks, a capsule maintains a more compact shape and is harder to elongate under a given external flow. Hence, the detachment process is slower for capsules compared to vesicles with the same Ks.

  16. Closed Loop Control of a Tethered Magnetic Capsule Endoscope.

    Science.gov (United States)

    Taddese, Addisu Z; Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2016-06-01

    Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy.

  17. Effects of powder flow properties on capsule filling weight uniformity.

    Science.gov (United States)

    Osorio, Juan G; Muzzio, Fernando J

    2013-09-01

    Filling capsules with the right amount of powder ingredients is an important quality parameter. The purpose of this study was to develop effective laboratory methods for characterizing flow properties of pharmaceutical powder blends and correlating such properties to weight variability in filled capsules. The methods used for powder flow characterization were bulk and tapped density, gravitational displacement rheometer (GDR) flow index, Freeman Technology V.4 (FT4) powder rheometer compressibility, FT4 basic flow energy (BFE), and cohesion parameters [cohesion, (C) and flow factor (ffc)] measured in a shear cell also using the FT4. Capsules were filled using an MG2-G140 continuous nozzle dosator capsule-filling machine. Powder flow properties were the most predominant factors affecting the weight and weight variability in the filled capsules. Results showed that the weight variability decreased with increasing bulk and tapped density, ffc and BFE, while the weight variability increased with increasing compressibility, cohesion and GDR flow index. Powder flow properties of the final blends were significantly correlated to the final capsule weight and weight variability of the filled capsules.

  18. Polyelectrolyte multilayer capsules as vehicles with tunable permeability.

    Science.gov (United States)

    Antipov, Alexei A; Sukhorukov, Gleb B

    2004-11-29

    This review is devoted to a novel type of polymer micro- and nanocapsules. The shell of the capsule is fabricated by alternate adsorption of oppositely charged polyelectrolytes (PEs) onto the surface of colloidal particles. Cores of different nature (organic or inorganic) with size varied from 0.1 to 10 mum can be used for templating such PE capsules. The shell thickness can be tuned in nanometer range by assembling of defined number of PE layers. The permeability of capsules depends on the pH, ionic strength, solvent, polymer composition, and shell thickness; it can be controlled and varied over wide range of substances regarding their molecular weight and charge. Including functional polymers into capsule wall, such as weak PEs or thermosensitive polymers, makes the capsule permeability sensitive to correspondent external stimuli. Permeability of the capsules is of essential interest in diverse areas related to exploitation of systems with controlled and sustained release properties. The envisaged applications of such capsules/vesicles cover biotechnology, medicine, catalysis, food industry, etc.

  19. Acute and chronic tears of anterior cruciate ligament : role of gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Jee, Won Hee; Im, Soo A; Chun, Ho Jong; Jung, Hyun Seouk; Kim, Soo Young; Kwon, Tae An; Song, Sun Wha; Choi, Kyu Ho

    1998-01-01

    To evaluate the efficacy of fat-suppressed gadolinium-enhanced MR imaging in differentiating acute from chronic ligament tears of anterior cruciate ligament. Materials and Methods : MR images of 22 patients with arthroscopically proven complete tear of the anterior cruciate ligament were retrospectively reviewed. The interval between injury and MR examination was one day to seven years. When ligament tear was detected on MR image with three months of injury, the case was considered acute;if detected after three months had elapsed, it was judged to be chronic. The extent of contrast enhancement was graded as 1, 2 or 3; grade 1, enhancement was confined to the expected ligament region; grade 2, enhancement extended to the joint capsule; grade 3, enhancement extended beyond the joint capsule. The grades of contrast enhancement correlated with the acute and chronic stages of ligament tears. Associated bone bruise and/or adjacent soft tissue edema were also evaluated. Results : Among 15 patients with acute ligament tear, nine (60%) showed grade 3 enhancement; among seven in whom tearing was chronic, four (57%) showed grade 1 enhancement. Bone bruising was present in 100% of acute tears (15/15) and 29 % of chronic tears (2/7). Soft tissue edema was associated in 87% of acute tears (13/15) and 29% of chronic tears(2/7). Conclusion : Fat-suppressed gadolinium-enhanced MR imaging could help differentiate acute from chronic tears of anterior cruciate ligament, as well as bone bruising and tissue edema

  20. Wireless pH capsule--yield in clinical practice.

    Science.gov (United States)

    Roman, S; Mion, F; Zerbib, F; Benamouzig, R; Letard, J C; Bruley des Varannes, S

    2012-03-01

    Wireless pH monitoring is one of the recent technologies that focus on improving the diagnosis of gastroesophageal reflux disease (GERD). The capsule, which is fixed within the esophagus, transmits data via telemetry to an external receiver. The capsule is usually inserted 6 cm above the squamocolumnar junction during an upper endoscopy. The standard recording duration is 48 hours but this can be extended to 96 hours. The wireless capsule has been shown to be at least as accurate as the conventional catheter for the monitoring of esophageal pH. Normal pH values have been established in three different series. The use of a wireless capsule provides an increased diagnostic yield for GERD compared with the conventional catheter. The increased yield is the result of higher sensitivity to detect both abnormal acid esophageal exposure and positive symptom-reflux association. This may be related both to the prolonged recording duration and to fewer dietary modifications and restrictions on activities. Several studies have shown that the pH capsule was better tolerated by patients than the conventional pH catheter. Mild-to-moderate chest pain represents the main side effect of the pH capsule: severe chest pain requiring endoscopic removal of the capsule is rare. The main indication for wireless capsule application is monitoring of distal esophageal pH for diagnostic purpose, particularly in patients with a normal endoscopic examination. The capsule technique has some limitations: costs are higher than conventional pH monitoring, misplacement may occur, and the sampling rate is lower. Finally, compared with pH-impedance monitoring, only acid reflux events can be evaluated. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    International Nuclear Information System (INIS)

    Koivikko, M.P.; Mustonen, A.O.T.

    2008-01-01

    , depending on anticipated shoulder pathology, is recommended. Because in posterior injections all artifacts were posterior and readily recognizable, it seems especially suitable for suspected anterior rotator cuff, joint capsule, and labral pathologies

  2. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Mustonen, A.O.T. (Dept. of Radiology, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2008-10-15

    , depending on anticipated shoulder pathology, is recommended. Because in posterior injections all artifacts were posterior and readily recognizable, it seems especially suitable for suspected anterior rotator cuff, joint capsule, and labral pathologies

  3. Toxic anterior segment syndrome following deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Neslihan Sevimli

    Full Text Available ABSTRACT We present the case of a 31-year-old patient with toxic anterior segment syndrome (TASS that developed after undergoing deep anterior lamellar keratoplasty (DALK. She had keratoconus, and despite wearing hard contact lenses for many years in the left eye, her vision had deteriorated; therefore, DALK was performed on this eye. The preoperative visual acuity (VA was finger counting at 3 m. Routine DALK was performed using the "big-bubble" technique. The corneal entry incision was hydrated at the end of the surgery, which was terminated by air injection into the anterior chamber. On postoperative day 1, VA was at the level of hand movements, and the cornea was edematous. Topical high-dose dexamethasone and oral steroids were initiated considering the diagnosis of TASS. Subsequently, the patient's VA increased, and the corneal edema decreased. We believe that the use of re-sterilized cannulas may have been the likely cause of TASS. Although DALK can be performed without interfering with the anterior chamber, one should keep in mind that TASS may occur in response to the solution used to hydrate the incision site and the air injected into the anterior chamber.

  4. Anterior ankle arthroscopy, distraction or dorsiflexion?

    NARCIS (Netherlands)

    de Leeuw, P.A.J.; Golanó, P.; Clavero, J.A.; van Dijk, C.N.

    2010-01-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly

  5. OdoCapsule: next-generation wireless capsule endoscopy with accurate lesion localization and video stabilization capabilities.

    Science.gov (United States)

    Karargyris, Alexandros; Koulaouzidis, Anastastios

    2015-01-01

    In this paper, we propose a platform to achieve accurate localization of small-bowel lesions and endoscopic video stabilization in wireless capsule endoscopy. Current research modules rely on the use of external magnetic fields and triangulation methods to calculate the position vector of the capsule, leading to considerable error margins. Our platform, entitled OdoCapsule (a synthesis of the words Odometer and Capsule), provides real-time distance information from the point of duodenal entry to the point of exit from the small bowel. To achieve this, OdoCapsule is equipped with three miniature legs. Each leg carries a soft rubber wheel, which is made with human-compliant material. These legs are extendable and retractable thanks to a micromotor and three custom-made torsion springs. The wheels are specifically designed to function as microodometers: each rotation they perform is registered. Hence, the covered distance is measured accurately in real time. Furthermore, with its legs fully extended, OdoCapsule can stabilize itself inside the small-bowel lumen thus offering smoother video capture and better image processing. Recent ex vivo testing of this concept, using porcine small bowel and a commercially available (custom-modified) capsule endoscope, has proved its viability.

  6. SATCAP-C : a program for thermal hydraulic design of pressurized water injection type capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Asoh, Tomokazu; Niimi, Motoji

    1992-10-01

    There are capsules called 'Pressure Water Injection Type Capsule' as a kind of irradiation devices at the Japan Materials Testing Reactor (JMTR). A type of the capsules is a 'Boiling Water Capsule' (usually named BOCA). The other type is a 'Saturated Temperature Capsule' (named SATCAP). When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature so far as the water does not fully change to steam. These type capsules are designed on the basis of the conception of applying the water characteristic to the control of irradiation temperature of specimens in the capsules. In designing of the capsules in which the pressurized water is injected, thermal performances have to be understood as exactly as possible. It is not easy however to predict thermal performances such as axially temperature distribution of water injected in the capsule, because there are heat-sinks at both side of inner and outer of capsule casing as the result that the water is fluid. Then, a program (named SATCAP-C) for the BOCA and SATCAP was compiled to grasp the thermal performances in the capsules and has been used the design of the capsules and analysis of the data obtained from some actual irradiation capsules. It was confirmed that the program was effective in thermal analysis for the capsules. The analysis found out the values for heat transfer coefficients at various surfaces of capsule components and some thermal characteristics of capsules. (author)

  7. Area densitometry using rotating Scheimpflug photography for posterior capsule opacification and surface light scattering analyses.

    Science.gov (United States)

    Minami, Keiichiro; Honbo, Masato; Mori, Yosai; Kataoka, Yasushi; Miyata, Kazunori

    2015-11-01

    To compare area densitometry analysis using rotating Scheimpflug photography in quantifications of posterior capsule opacification (PCO) and surface light scattering with previous anterior-segment analyzer measurement. Miyata Eye Hospital, Miyazaki, Japan. Prospective observational case series. Scheimpflug images of eyes with foldable intraocular lenses (IOLs) were obtained using rotating and fixed Scheimpflug photography. Area densitometry on the posterior and anterior surfaces was conducted for PCO and surface light scattering analyses, respectively, with an identical area size. Correlation between two measurements was analyzed using linear regression. The study included 105 eyes of 74 patients who received IOLs 1 to 18 years (mean, 4.9 ± 4.5 years) postoperatively. In the PCO analysis on the posterior IOL surface, there was a significant correlation between the two measurements (P photography exhibited saturation due to intensive scatterings. Area densitometry combined with a rotating Scheimpflug photography was exchangeable to previously established densitometry measurement, and allowed successive evaluation in longer-term observations. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Application and improvement of capsule system for penstocks

    Energy Technology Data Exchange (ETDEWEB)

    Matstuda, S.; Fujishiro, Y.; Yamagucki, T.; Okubo, M.; Miyabe, N.; Sakagami, H.; Ikeda, M.; Kurose, Y.

    1981-01-01

    Kawasaki Heavy Industries, Ltd. has succeeded in applying an all-position, narrow-gap MIG automatic welding method using a Capsule System for both penstocks of the Electric Power Development Company's Okukiyotsu and the Kansai Electric Power Company's Okuyoshino Pumped Storage Hydroelectric Power Stations. The application and development of the capsule system and MIG welding method have been officially commended this year by the Japan Society of Steel Construction (JSSC). The KHI-development capsule system has been improved by the study of various data rendered by the aforesaid two projects. Based on past experience, KHI is now involved in the construction of another penstock, this one for the Tokoku Electric Power Company's No. 2 Numazawa Pumped Storage Hydroelectric Power Station. The design and improvements of the capsule system, and its application to Numazawa Penstock are discussed.

  9. Colon capsule endoscopy: Advantages, limitations and expectations. Which novelties?

    Science.gov (United States)

    Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Spada, Cristiano; Costamagna, Guido

    2012-01-01

    Since the first reports almost ten years ago, wireless capsule endoscopy has gained new fields of application. Colon capsule endoscopy represents a new diagnostic technology for colonic exploration. Clinical trials have shown that colon capsule endoscopy is feasible, accurate and safe in patients suffering from colonic diseases and might be a valid alternative to conventional colonoscopy in selected cases such as patients refusing conventional colonoscopy or with contraindications to colonoscopy or when colonoscopy is incomplete. Despite the enthusiasm surrounding this new technique, few clinical and randomized controlled trials are to be found in the current literature, leading to heterogeneous or controversial results. Upcoming studies are needed to prove the substantial utility of colon capsule endoscopy for colon cancer screening, especially in a low prevalence of disease population, and for other indications such as inflammatory bowel disease. Possible perspectives are critically analysed and reported in this paper. PMID:22523610

  10. Positron radiography of ignition-relevant ICF capsules

    Science.gov (United States)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  11. Secondary Stabilizers of Tibial Rotation in the Intact and Anterior Cruciate Ligament Deficient Knee.

    Science.gov (United States)

    Kaplan, Daniel James; Jazrawi, Laith M

    2018-01-01

    The controversy regarding the existence and function of the anterolateral ligament or anterolateral complex has reinvigorated interest in rotational stability of the knee joint. This is particularly true of anterolateral rotary instability, as many patients, despite anatomic reconstruction of their anterior cruciate ligament, continue to experience instability. Many experts point toward compromised anterolateral restraints as the underlying culprit, namely, the anterolateral complex, which includes the iliotibial band, anterolateral capsule, lateral meniscus, and lateral collateral ligament. This article provides a breakdown of these structures, their function, biomechanical properties, and clinical importance, based on a thorough review of available literature. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The power of product innovation: Smokers' perceptions of capsule cigarettes.

    Science.gov (United States)

    Moodie, Crawford; Ford, Allison; Dobbie, Fiona; Thrasher, James F; McKell, Jennifer; Purves, Richard

    2017-08-30

    Since being brought to market in 2007, cigarettes with capsules in the filter that can be burst to change the flavour have had remarkable global success, highlighting the importance of product innovation for tobacco companies. Very few studies have explored how these products are perceived by smokers however. This paper sought to address this gap by exploring smokers' awareness of cigarettes with one or two flavour-changing capsules in the filter and the appeal of these products. Twenty focus groups were conducted in Glasgow and Edinburgh in 2015 with current smokers (N=120), segmented by age (16-17, 18-24, 25-35, 36-50, >50), gender and social grade. Awareness, use and appeal of capsule cigarettes was greater among younger adults (16-35 years), who showed most interest in these products. Those who perceived capsules positively mentioned multiple benefits: the ability to burst the capsule, convenience of being able to share cigarettes among menthol and non-menthol smokers, better taste, fresher breath, reduced smell and greater discretion. It was suggested that capsule cigarettes, particularly the double capsule cigarette (which had two differently flavoured capsules in the filter), would encourage non-smokers to experiment with smoking and discourage smokers from quitting. The findings offer some reasons behind the global growth of the capsule cigarette segment. Cigarettes with flavour-changing capsules in the filter have been one of the most successful product innovations of the last decade for tobacco companies. They have received very little academic attention however. Employing focus groups with 120 smokers aged 16 and over, we found that capsule cigarettes held most appeal to, and were considered to be targeted at, younger people, with it suggested that these products would encourage initiation and discourage cessation. This study provides some understanding of how these products are viewed by smokers. © The Author 2017. Published by Oxford University Press

  13. Postirradiation examination of capsule P13Q

    International Nuclear Information System (INIS)

    Young, C.A.; Scott, C.B.

    1977-09-01

    Capsule P13Q was the sixth in a series of irradiation tests conducted under the HTGR Fuels and Core Development Program. It was the first accelerated irradiation test of large-diameter graphite-fuel bodies irradiated to peak LHTGR fast fluences. The primary purpose of the test was to evaluate the irradiation performance of the integral bodies and cured-in-place fuel rods. One TRISO UC 2 and two BISO ThO 2 coated particle batches were used in the fuel rods. The postirradiation examination revealed that the performance of the H-451 graphite bodies and fuel rods irradiated to a peak fluence of 9.5 x 10 25 n/m 2 (E greater than 29 fJ)/sub HTGR/ and to an average peak fuel rod temperature of 1175 0 C was acceptable. A range of fuel rod variables was tested and none were detrimental to the integrity of the rods. The coated fuel particles behaved in a manner predicted by previous irradiation data

  14. 131-iodine capsules in thyroid therapy

    International Nuclear Information System (INIS)

    Schulthess, G.K. von; Bekier, A.

    1985-01-01

    We investigated the uptake of therapeutic doses of 131-Iodine in a capsular form which were given to 16 patients with benign thyroid disease, and compared it to the uptake of a dose of a liquid diagnostic sodium iodide I-131 ( 131 I) given to the same patients. The aim of this study was to determine the additional radiation dose sustained by the gastric mucosa, and thus, to establish the safety of this galenic form of 131 I. It was found that the average capsule-dissolution time was about 12 min, with a large standard deviation of about 7 min. Using these data and a theoretical radiation-dose calculation, we estimated that the maximum dose to the gastric mucosa was approximately 250 rad (250 cGy) for a therapeutic activity of 5 mCi (185 MBq), which is the maximum dose which may be given as single application to out-patients in Switzerland. Thus, 131 I administered in a capsular form is a safe galenic form for therapeutic use in patients with thyroid disease. (orig.)

  15. A UWB wireless capsule endoscopy device.

    Science.gov (United States)

    Thotahewa, Kasun M S; Redoute, Jean-Michel; Yuce, Mehmet Rasit

    2014-01-01

    Wireless capsule endoscopy (WCE) presents many advantages over traditional wired endoscopic methods. The performance of WCE devices can be improved using high-frequency communication systems such as Impulse Radio-Ultra-Wideband (IR-UWB) to enable a high data rate transmission with low-power consumption. This paper presents the hardware implementation and experimental evaluation of a WCE device that uses IR-UWB signals in the frequency range of 3.5 GHz to 4.5 GHz to transmit image data from inside the body to a receiver placed outside the body. Key components of the IR-UWB transmitter, such as the narrow pulse generator and up-conversion based RF section are described in detail. This design employs a narrowband receiver in the WCE device to receive a control signal externally in order to control and improve the data transmission from the device in the body. The design and performance of a wideband implantable antenna that operates in the aforementioned frequency range is also described. The operation of the WCE device is demonstrated through a proof-of-concept experiment using meat.

  16. Capsule Endoscopy for Portal Hypertensive Enteropathy

    Directory of Open Access Journals (Sweden)

    Seong Ran Jeon

    2016-01-01

    Full Text Available Portal hypertensive enteropathy (PHE is a mucosal abnormality of the small bowel that is observed in patients with portal hypertension (PH and can lead to gastrointestinal bleeding and anemia. The pathogenesis is still not completely understood. The introduction of new endoscopic methods, including capsule endoscopy (CE or balloon-assisted enteroscopy, has increased the detection of these abnormalities. CE can also serve as a road map for deciding subsequent interventions and evaluating the treatment effect. The prevalence of PHE is reportedly 40–70% in patients with PH. Endoscopic findings can be roughly divided into vascular and nonvascular lesions such as inflammatory-like lesions. Traditionally, PHE-associated factors include large esophageal varices, portal hypertensive gastropathy or colopathy, Child-Turcotte-Pugh class B or C, a history of variceal treatment, and acute gastrointestinal bleeding. More recently, on using scoring systems, a high computed tomography or transient elastography score was reportedly PHE-related factors. However, the prevalence of PHE and its related associated factors remain controversial. The management of PHE has not yet been standardized. It should be individualized according to each patient’s situation, the availability of therapy, and each institutional expertise.

  17. Orion Capsule Handling Qualities for Atmospheric Entry

    Science.gov (United States)

    Tigges, Michael A.; Bihari, Brian D.; Stephens, John-Paul; Vos, Gordon A.; Bilimoria, Karl D.; Mueller, Eric R.; Law, Howard G.; Johnson, Wyatt; Bailey, Randall E.; Jackson, Bruce

    2011-01-01

    Two piloted simulations were conducted at NASA's Johnson Space Center using the Cooper-Harper scale to study the handling qualities of the Orion Command Module capsule during atmospheric entry flight. The simulations were conducted using high fidelity 6-DOF simulators for Lunar Return Skip Entry and International Space Station Return Direct Entry flight using bank angle steering commands generated by either the Primary (PredGuid) or Backup (PLM) guidance algorithms. For both evaluations, manual control of bank angle began after descending through Entry Interface into the atmosphere until drogue chutes deployment. Pilots were able to use defined bank management and reversal criteria to accurately track the bank angle commands, and stay within flight performance metrics of landing accuracy, g-loads, and propellant consumption, suggesting that the pilotability of Orion under manual control is both achievable and provides adequate trajectory performance with acceptable levels of pilot effort. Another significant result of these analyses is the applicability of flying a complex entry task under high speed entry flight conditions relevant to the next generation Multi Purpose Crew Vehicle return from Mars and Near Earth Objects.

  18. Anterior ethmoid anatomy facilitates dacryocystorhinostomy.

    Science.gov (United States)

    Blaylock, W K; Moore, C A; Linberg, J V

    1990-12-01

    The ethmoid air cell labyrinth lies adjacent to the medial orbital wall, extending even beyond the sutures of the ethmoid bone. Its anatomic relationship to the lacrimal sac fossa is important in lacrimal surgery. We evaluated computed tomographic scans of 190 orbits with normal ethmoid anatomy to define the anatomic relationship of anterior ethmoid air cells to the lacrimal sac fossa. In 93% of the orbits, the cells extended anterior to the posterior lacrimal crest, with 40% entering the frontal process of the maxilla. This anatomic relationship may be used to facilitate the osteotomy during dacryocystorhinostomy. During a 10-year period (310 cases), one of us routinely entered the anterior ethmoid air cells to initiate the osteotomy during dacryocystorhinostomy. This technique has helped to avoid lacerations of the nasal mucosa.

  19. Demonstration of Polysaccharide Capsule in Campylobacter jejuni Using Electron Microscopy

    OpenAIRE

    Karlyshev, Andrey V.; McCrossan, Maria V.; Wren, Brendan W.

    2001-01-01

    Recently, we reported that Campylobacter jejuni, an important gastrointestinal pathogen, has the genetic determinants to produce a capsular polysaccharide (Karlyshev et al., Mol. Microbiol. 35:529–541, 2000). Despite these data, the presence of a capsule in these bacteria has remained controversial. In this study we stain C. jejuni cells with the cationic dye Alcian blue and demonstrate for the first time by electron microscopy that C. jejuni cells produce a polysaccharide capsule that is ret...

  20. Polysaccharide capsule-mediated resistance to opsonophagocytosis in Klebsiella pneumoniae.

    OpenAIRE

    Domenico, P; Salo, R J; Cross, A S; Cunha, B A

    1994-01-01

    The polysaccharide capsule of Klebsiella pneumoniae is an important virulence factor that confers resistance to phagocytosis. The treatment of encapsulated bacteria with salicylate to inhibit capsule expression was found to enhance the phagocytosis of encapsulated bacteria by human neutrophils only in the presence of cell surface-specific antibodies. Both type-specific rabbit antisera and anticapsular human hyperimmune globulin were employed as opsonins. Salicylate significantly enhanced phag...

  1. The association of metabolic syndrome markers with adhesive capsulitis.

    Science.gov (United States)

    Austin, Daniel C; Gans, Itai; Park, Min Jung; Carey, James L; Kelly, John D

    2014-07-01

    Research has associated adhesive capsulitis with diabetes mellitus but suggests that glucose-mediated injury may begin before diabetes is diagnosed. The period preceding diabetes is often marked by metabolic syndrome. We investigated the relationship between metabolic syndrome components (insulin resistance, hypertension, dyslipidemia, and obesity) and the development of adhesive capsulitis using a case-control study. We retrospectively reviewed 150 consecutive adhesive capsulitis patient charts to determine the prevalence of obesity and of medications used for treating metabolic syndrome elements and compared these with previously reported nationwide values. The prevalence of anti-hyperglycemia medications in the adhesive capsulitis cohort was 18.4% (95% confidence interval [CI], 12.9%-25.7%), twice the national rate of diagnosed diabetes of 7.6% (95% CI, 6.7%-8.5%). In the 20- to 39-year-old group, the prevalence of anti-hyperglycemic medications, 26.3% (95% CI, 11.8%-48.8%), was over 10 times the nationwide rate. The overall prevalence of hypertensive medication use in the adhesive capsulitis group, 33.1% (95% CI, 25.9%-41.2%), was notably higher than the nationwide rate, 21.6% (95% CI, 19.8%-23.4%). In the 40- to 64-year-old group, the prevalence of hypertensive medication use, 36.8% (95% CI, 28.6%-46.0%), was notably higher than the nationwide rate of 24.5% (95% CI, 22.2%-27.0%). The prevalence of anti-lipid medications and obesity was similar between the groups. The relationship between adhesive capsulitis and metabolic syndrome remains unclear. Our results confirm previous work associating hyperglycemia with adhesive capsulitis. We have also shown a possible association of hypertension, part of metabolic syndrome and a proinflammatory condition, with adhesive capsulitis, which has not been previously described. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. Editorial Commentary: Recalcitrant Idiopathic Adhesive Capsulitis of the Shoulder.

    Science.gov (United States)

    Yoo, Jae Chul

    2017-03-01

    An investigation of recalcitrant idiopathic adhesive capsulitis of the shoulder showed good outcomes with arthroscopic capsular release. However, it is critical that future authors carefully define the term "recalcitrant idiopathic adhesive capsulitis" so that we are speaking the same language and that future authors include a control (nonsurgical) treatment group to better determine whether surgery is truly superior to nonsurgical treatment. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. PHYSIOTHERAPY INTERVENTIONS FOR ADHESIVE CAPSULITIS OF SHOULDER: A SYSTEMATIC REVIEW

    OpenAIRE

    Jacob Isaac Jason; Ganesh Sundaram S; Vengata Subramani M

    2015-01-01

    Objective: The purpose of this study was to conduct a systematic review on various physiotherapy management for adhesive capsulitis of shoulder. Methods: A search of the literature was conducted using Clinical Key, ProQuest and PEDro databases up to September 2015. Search limits included the English language and human studies. Search terms included adhesive capsulitis, frozen shoulder, Physical therapy, Physiotherapy etc. Inclusion criteria: Systematic reviews and randomised controlled ...

  4. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder

    OpenAIRE

    Fernandes, Marcos Rassi

    2014-01-01

    OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up o...

  5. Effectiveness of Maitland Techniques in Idiopathic Shoulder Adhesive Capsulitis

    OpenAIRE

    Kumar, Abhay; Kumar, Suraj; Aggarwal, Anoop; Kumar, Ratnesh; Das, Pooja Ghosh

    2012-01-01

    Objective. To study the effectiveness of Maitland techniques in the treatment of idiopathic shoulder adhesive capsulitis. Methods. total of 40 patients diagnosed with idiopathic shoulder adhesive capsulitis were recruited and randomly allocated into two groups. In Group A ( ) subjects were treated with Maitland mobilization technique and common supervised exercises, whereas subjects in Group B ( ) only received common supervised exercises. Variables. Shoulder pain and disability index (SPADI)...

  6. Clinical outcomes of pars plicata anterior vitrectomy: 2-year results

    Directory of Open Access Journals (Sweden)

    Priya Narang

    2015-01-01

    Full Text Available Purpose: To demonstrate the safety and outcome of a surgical approach that uses pars plicata site for anterior vitrectomy during phacoemulsification procedure complicated by posterior capsule rupture and residual cortical matter. Design: Single center, retrospective, interventional, noncomparative study. Materials and Methods: Medical records of a consecutive series of 35 eyes of 35 patients who underwent pars plicata anterior vitrectomy (PPAV were reviewed. The main outcome measures were corrected and uncorrected distance visual acuity (CDVA, UDVA, early and late postoperative complications and intraocular pressure (IOP. Ultrasound biomicroscopic (UBM evaluation of sclerotomy site and spectral domain optical coherence tomography analysis for central macular thickness (CMT was performed. The final visual outcome at 2 years was evaluated. Results: At 2 years follow-up, the mean postoperative UDVA (logarithm of the minimum angle of resolution [logMAR] and CDVA (logMAR was 0.49 ± 0.26 and 0.19 ± 0.14, respectively. There was no significant change in the IOP (P = 0.061 and the mean CMT at 2 years was 192.5 ± 5.54 mm. The postoperative UBM image of the sclerotomy site at 8 weeks demonstrated a clear wound without any vitreous adhesion or incarceration. Intraoperative hyphema was seen in 1 (2.8% case and postoperative uveitis was seen in 2 (5.7% cases, which resolved with medications. No case of an iatrogenic retinal break or retinal detachment was reported. Conclusions: PPAV enables a closed chamber approach, allows thorough cleanup of vitreous in the pupillary plane and anterior chamber and affords better access to the subincisional and retropupillary cortical remnant with a significant visual outcome and an acceptable complication rate.

  7. The external rotation test in the diagnosis of adhesive capsulitis.

    Science.gov (United States)

    Wolf, Eugene M; Cox, Wesley K

    2010-05-12

    This article evaluates the effectiveness of the external rotation test in diagnosing capsulitis. The test is performed with the upper arm in a neutral position at the patient's side and the elbow in 90 degrees of flexion. The test is positive when pain is produced with this maneuver. All patients (379) evaluated for atraumatic shoulder pain during 1 calendar year were studied. The patients were divided into external rotation positive (91 patients) and external rotation negative (311 patients) groups. Patients with atraumatic shoulder pain with a positive external rotation test were presumed to have adhesive capsulitis in the absence of glenohumeral arthritis. Patients diagnosed with adhesive capsulitis received an intra-articular steroid injection and a home therapy program. Patients were contacted 10 to 19 months following treatment to determine their status and need for any further care. A diagnosis of adhesive capsulitis was made in 75% of external rotation positive patients (68 patients). Glenohumeral arthritis evidenced by radiographs was the only other diagnosis that produced a positive external rotation test (23 patients) in this group of atraumatic shoulders. Only 1 of 68 patients (1.4%) with a diagnosis of adhesive capsulitis (external rotation positive) had surgery during the follow-up period. However, 86 of 311 (27.7%) patients in the external rotation negative group underwent surgery (Padhesive capsulitis in the absence of glenohumeral arthritis. Copyright 2010, SLACK Incorporated.

  8. Colloidal capsules: nano- and microcapsules with colloidal particle shells.

    Science.gov (United States)

    Bollhorst, Tobias; Rezwan, Kurosch; Maas, Michael

    2017-04-18

    Utilizing colloidal particles for the assembly of the shell of nano- and microcapsules holds great promise for the tailor-made design of new functional materials. Increasing research efforts are devoted to the synthesis of such colloidal capsules, by which the integration of modular building blocks with distinct physical, chemical, or morphological characteristics in a capsule's shell can result in novel properties, not present in previous encapsulation structures. This review will provide a comprehensive overview of the synthesis strategies and the progress made so far of bringing nano- and microcapsules with shells of densely packed colloidal particles closer to application in fields such as chemical engineering, materials science, or pharmaceutical and life science. The synthesis routes are categorized into the four major themes for colloidal capsule formation, i.e. the Pickering-emulsion based formation of colloidal capsules, the colloidal particle deposition on (sacrificial) templates, the amphiphilicity driven self-assembly of nanoparticle vesicles from polymer-grafted colloids, and the closely related field of nanoparticle membrane-loading of liposomes and polymersomes. The varying fields of colloidal capsule research are then further categorized and discussed for micro- and nano-scaled structures. Finally, a special section is dedicated to colloidal capsules for biological applications, as a diverse range of reports from this field aim at pharmaceutical agent encapsulation, targeted drug-delivery, and theranostics.

  9. Capsule Development and Utilization for Material Irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2003-05-01

    The objective of this project was to establish basic capsule irradiation technology using the multi-purpose research reactor [HANARO] to eventually support national R and D projects of advanced fuel and materials related to domestic nuclear power plants and next generation reactors. There are several national nuclear projects in KAERI, which require several irradiation tests to investigate in-pile behavior of nuclear reactor fuel and materials for the R and D of several types of fuels such as advanced PWR and DUPIC fuels and for the R and D of structural materials such as RPV(reactor pressure vessel) steel, Inconel, zirconium alloy, and stainless steel. At the moment, internal and external researchers in institutes, industries and universities are interested in investigating the irradiation characteristics of materials using the irradiation facilities of HANARO. For these kinds of material irradiation tests, it is important to develop various capsules using our own techniques. The development of capsules requires several leading-edge technologies and our own experiences related to design and fabrication. In the second phase from April 1,2000 to March 31, 2003, the utilization technologies were developed using various sensors for the measurements of temperature, pressure and displacement, and instrumented capsule technologies for the required fuel irradiation tests were developed. In addition, the improvement of the existing capsule technologies and the development of an in-situ measurable creep capsule for specific purposes were done to meet the various requirements of users

  10. Capsule colonoscopy increases uptake of colorectal cancer screening

    Directory of Open Access Journals (Sweden)

    Groth Stefan

    2012-06-01

    Full Text Available Abstract Background Screening colonoscopy effectiveness is hampered by limited adherence by the general population. The present prospective study was performed to evaluate whether adding capsule colonoscopy to the endoscopic screening options increases uptake. Methods Invitation letters were sent to 2150 persons above the age of 55 insured with a German medical insurance company in the area of Rinteln, Lower Saxony with a baseline spontaneous annual screening colonoscopy uptake of 1 %. Both capsule or conventional colonoscopy were offered. Interested persons were given information about the two screening options by four local gastroenterologists and examinations were then performed according to screenees’ final choice. Results 154 persons sought further information, and 34 and 90 underwent conventional and capsule colonoscopy, respectively. Colonoscopy uptake was thus increased by the invitation process by 60 % (1.6 % vs. 1 %; p = 0.075, while the option of capsule endoscopy led to a fourfold increase of screening uptake (4.2 % vs. 1 %, p  Conclusions The present study suggests that offering the option of capsule colonoscopy increases uptake of endoscopic colorectal cancer screening. However, capsule endoscopy sensitivity for adenoma detection needs to be improved.

  11. Failure of the capsule for coated particles irradiation

    International Nuclear Information System (INIS)

    Yamaki, Jikei; Nomura, Yasushi; Nagamatsuya, Takaaki; Yamahara, Takeshi; Sakai, Haruyuki

    1975-10-01

    During operation cycle No. 27 of the JMTR (Japan Material Testing Reactor) on May 20, 1974, leakage of the fission product gas occurred from the capsule 72F-7A, which contained coated particles for the irradiation; the coated particles are for the development of a multi-purpose high temperature gas cooled reactor. The capsule was designed for heat 1600 0 C. Three nickel plates as the heat reflector were sandwiched in between the plates of titanium and zirconium, which were adsorbents for the impurity gases in the cladding tube (Nb-1%Zr). Temperatures of the plates were about 1000 0 C under the irradiation, so one metal diffused into the other metal through interfaces, resulting in the formation of an alloy. Its melting point was lower than those of metals in the capsule. The cladding material Nb-1%Zr was melted by the alloy and finally a pin hole developed through the cladding. The process of failure, design of the capsule, post-irradiation test of the capsule and the failure-reproducing experiment with a mock-up capsule are described. (auth.)

  12. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  13. Anatomic anterior cruciate ligament reconstruction: reducing anterior tibial subluxation

    NARCIS (Netherlands)

    Muller, Bart; Duerr, Eric R. H.; van Dijk, C. Niek; Fu, Freddie H.

    2016-01-01

    To measure and compare the amount of anterior tibial subluxation (ATS) after anatomic ACL reconstruction for both acute and chronic ACL-deficient patients. Fifty-two patients were clinically and radiographically evaluated after primary, unilateral, anatomic ACL reconstruction. Post-operative true

  14. Arthroscopic Latarjet and Capsular Shift (ALCS) procedure: a new "freehand" technique for anterior shoulder instability associated with significant bone defects.

    Science.gov (United States)

    Bhatia, Deepak N

    2015-03-01

    Anterior shoulder instability associated with significant bone loss has been described as "bony-instability," and this condition is usually treated with an anterior glenoid bone grafting procedure (Latarjet procedure). The Latarjet procedure involves transfer of the horizontal limb of the coracoid process along with the conjoint tendon to the anterior glenoid rim, and is traditionally performed as an open surgical procedure. Recently, an arthroscopic technique for the Latarjet procedure has been described; the technique necessitates the use of specialized instrumentation and involves excision of the entire anterior capsule to facilitate coracoid fixation. We describe a new "freehand" arthroscopic technique for the Latarjet procedure, and, in addition, a simultaneous capsular shift to further optimize mid and end range stability. This technique eliminates the use of additional instrumentation and can be done using routine arthroscopic instruments. Preliminary experience with this technique suggests that the arthroscopic Latarjet and capsular shift is a technically demanding procedure. Glenohumeral capsule can be preserved, and this should be attempted wherever possible to optimize stability. Additional specialized instrumentation would probably reduce surgical time; however, the procedure can be performed with routine instruments.

  15. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  16. Unaffected twins discordant for affective disorders show changes in anterior callosal white matter microstructure

    DEFF Research Database (Denmark)

    Macoveanu, J; Vinberg, M; Madsen, K.

    2016-01-01

    tracts, that is, cingulum bundle, uncinate fasciculus, anterior limb of the internal capsule, and corpus callosum, that facilitate the communication between brain regions implicated in affective disorders. METHOD: Eighty-nine healthy mono- or dizygotic twins with a co-twin diagnosed with MDD or BD (high...... communication between left and right frontal regions critically involved in mood regulation. Reduced anterior callosal FA may act as a vulnerability marker for affective disorders in individuals at familial risk.......OBJECTIVE: The neurobiological mechanisms mediating an increased risk to develop affective disorders remain poorly understood. In a group of individuals with a family history of major depressive (MDD) or bipolar disorder (BD), we investigated the microstructural properties of white matter fiber...

  17. Fracture of the anterior colliculus.

    Science.gov (United States)

    Skie, M C; Ebraheim, N A; Woldenberg, L; Randall, K

    1995-04-01

    The authors retrospectively reviewed 33 cases of fracture involving the anterior colliculus of the medial malleolus to examine clinical results of operative treatment for these fractures. Although this injury appears innocuous, it can be difficult to obtain stable fixation of the fragment intraoperatively, and painful nonunion can result. A simple reduction maneuver and method of tension band fixation are described.

  18. Electrotherapy modalities for adhesive capsulitis (frozen shoulder).

    Science.gov (United States)

    Page, Matthew J; Green, Sally; Kramer, Sharon; Johnston, Renea V; McBain, Brodwen; Buchbinder, Rachelle

    2014-10-01

    Adhesive capsulitis (also termed frozen shoulder) is a common condition characterised by spontaneous onset of pain, progressive restriction of movement of the shoulder and disability that restricts activities of daily living, work and leisure. Electrotherapy modalities, which aim to reduce pain and improve function via an increase in energy (electrical, sound, light, thermal) into the body, are often delivered as components of a physical therapy intervention. This review is one in a series of reviews which form an update of the Cochrane review 'Physiotherapy interventions for shoulder pain'. To synthesise the available evidence regarding the benefits and harms of electrotherapy modalities, delivered alone or in combination with other interventions, for the treatment of adhesive capsulitis. We searched CENTRAL, MEDLINE, EMBASE, CINAHL Plus and the ClinicalTrials.gov and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) clinical trials registries up to May 2014, unrestricted by language, and reviewed the reference lists of review articles and retrieved trials to identify any other potentially relevant trials. We included randomised controlled trials (RCTs) and controlled clinical trials using a quasi-randomised method of allocation that included adults with adhesive capsulitis and compared any electrotherapy modality to placebo, no treatment, a different electrotherapy modality, or any other intervention. The two main questions of the review focused on whether electrotherapy modalities are effective compared to placebo or no treatment, or if they are an effective adjunct to manual therapy or exercise (or both). The main outcomes of interest were participant-reported pain relief of 30% or greater, overall pain, function, global assessment of treatment success, active shoulder abduction, quality of life, and the number of participants experiencing any adverse event. Two review authors independently selected trials for inclusion

  19. Awful face of the war-impacted smoke bomb capsule in the face and systemic toxicity: reports from the conflict in Syria.

    Science.gov (United States)

    Yilmaz, Bahar; Yeşiloğlu, Nebil; Firincioğullari, Remzi; Gökkaya, Ali; Özbey, Rafet; Özgür, Mustafa

    2015-01-01

    In this study, a rare kind of injury due to smoke bomb capsule impaction to midface and under the cranial base is presented, and maneuvers to reduce mortality are discussed. Three male patients were presented with impacted smoke bomb capsules into the midface and under the cranial base structures. Midface structures, anterior cranial base, and, in 2 patients, unilateral eye were severely damaged. Two patients died after the initial emergency operations because their lung disease progressed to acute respiratory distress syndrome. One of the patients lived, and soft tissue reconstruction was achieved by using temporal transposition and cheek advancement skin flaps with split-thickness skin graft from donor site. However, craniofacial destruction is important in these patients; a multidisciplinary approach is needed for the treatment of direct smoke bomb injuries because the patients experienced chemical burn and acute trauma. The timing of maxillofacial reconstruction is also a question in these specific patients.

  20. Anatomia microcirúgica da substâcia perfurada anterior basal humana Microsurgical anatomy of the human basal anterior perforated substance

    Directory of Open Access Journals (Sweden)

    Arlindo Alfredo Silveira D’Ávila

    2006-06-01

    Full Text Available A substância perfurada anterior constitui referencial na base do encéfalo. Localizada acima da bifurcação subaracnóidea da artéria carótida interna em sua porção basal e junto à artéria comunicante anterior na face inter-hemisférica, é transfixada por ramos perfurantes dirigidos aos núcleos telencefálicos corticais, cápsula interna e parte do tálamo. Por injeção intravascular de gelatina carminada, resina de Batson e látex, analisamos 50 hemisférios cerebrais humanos adultos de ambos os sexos, sob o microscópio cirúrgico. Objetivamos contribuir para a determinação da origem, número e topografia dos ramos destinados a essa região, seu curso, anastomoses e territórios de penetração. Propusemo-nos também a analisar a contribuição da artéria comunicante anterior à substância perfurada anterior. Foram encontradas variações anatômicas, incluindo anastomoses, envolvendo principalmente a artéria cerebral média e a artéria coróidea anterior. Estes conhecimentos são de interesse clínico-cirúrgico em razão da freqüência de patologias vasculares e tumorais a ela relacionadas.The anterior perforated substance (APS is a landmark in the basal forebrain. It has a basal face located above the carotid bifurcation in the subarachnoid space, and an interhemispheric one. It is the site of passage of the arteries to the caudate nucleus, putamen, internal capsule, adjacent areas of the globus pallidus and thalamus. Fifty hemispheres from twenty-five adult cadavers were obtained. The arteries were perfused with colored latex, Batson’s resin and gelatin colored with carmine. Using a surgical microscope we have determined the origin, local and number of origin from the parent vessel. The sites of penetration in the mediolateral and anteroposterior direction were also recorded. The anterior communicating artery contribution to the basal APS was reviewed. Significant vascular variations and anastomoses were encountered

  1. Válvula de uretra anterior Anterior urethral valves

    Directory of Open Access Journals (Sweden)

    Silvio Tucci Jr.

    2003-02-01

    Full Text Available Objetivo: apresentar os aspectos clínicos, diagnósticos e terapêuticos de pacientes portadores de válvula da uretra anterior. Descrição: em dois neonatos, o diagnóstico presuntivo de patologia obstrutiva do trato urinário foi sugerido pela ultra-sonografia realizada no período pré-natal, confirmando-se o diagnóstico de válvula de uretra anterior pela avaliação pós-natal. Os pacientes foram submetidos a tratamento cirúrgico paliativo, com vesicostomia temporária e, posteriormente, definitivo, pela fulguração endoscópica das válvulas. Ambos evoluíram com função renal normal. Comentários: a válvula da uretra anterior é anomalia rara que deve ser considerada em meninos com quadro radiológico pré-natal sugestivo de obstrução infravesical, secundariamente à hipótese mais comum de válvula da uretra posterior. Ressaltamos a utilização da vesicostomia como derivação urinária temporária nestes casos, prevenindo potenciais complicações pela manipulação da uretra do recém-nascido.Objective: to discuss clinical signs, diagnostic tools and therapeutics of anterior urethral valves, an obstructive anomaly of the urinary system in males. Description: signs of urinary tract obstruction were identified on pre-natal ultrasound in two male fetuses and the diagnosis of anterior urethral valves was made through post-natal evaluation. As an initial treatment, vesicostomy was performed in both patients. Later, the valves were fulgurated using an endoscopic procedure. During the follow-up period both patients presented normal renal function. Comments: anterior urethral valves are a rare form of urethral anomaly that must be ruled out in boys with pre-natal ultrasound indicating infravesical obstruction. Vesicostomy used as an initial treatment rather than transurethral fulguration may prevent potential complications that can occur due to the small size of the neonatal urethra.

  2. Adhesive capsulitis of the shoulder: evaluation with MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong [Catholic University of Korea, Department of Radiology, Kangnam St. Mary' s Hospital, Seoul (Korea); Kim, Yang-Soo; Chung, Yang Guk; Kim, Jung-Man [Catholic University of Korea, Department of Orthopedic Surgery, Kangnam St. Mary' s Hospital, Seoul (Korea)

    2006-04-15

    The purpose of this study was to determine the usefulness of magnetic resonance (MR) arthrography for diagnosing adhesive capsulitis. Shoulder MR images of 28 patients with (n=14) and without (n=14) adhesive capsulitis were retrospectively analyzed. MR images were assessed for capsule and synovium thickness as well as the width of the axillary recess on oblique coronal fat-suppressed T1-weighted images and T2-weighted images, respectively. On oblique sagittal fat-suppressed T1-weighted images, the width of the rotator interval and the presence of abnormal tissue in the interval were evaluated. Significant differences were found between the two groups in capsule and synovium thickness on both sides of the recess on oblique coronal T2-weighted images (P=0.000), whereas thickness on the humeral aspect showed no significant difference on oblique coronal fat-suppressed T1-weighted images (P=0.109). On oblique coronal T2-weighted images, a cut-off value of 3-mm thickness gave the highest diagnostic accuracy for adhesive capsulitis with sensitivity, specificity, and accuracy of 79% (11/14), 100% (14/14), and 89% (25/28) at the humeral side and 93% (13/14), 86% (12/14), and 89% (25/28) at the glenoid side, respectively. There were significant differences in rotator interval width, presence of abnormal tissue in the rotator interval, and axillary recess width between the two groups (P<0.05). Thickness of capsule and synovium of the axillary recess greater than 3 mm is a practical MR criterion for diagnosing adhesive capsulitis when measured on oblique coronal T2-weighted MR arthrography images without fat suppression. The presence of abnormal tissue in the rotator interval showed high sensitivity but rather low specificity. (orig.)

  3. Overview of technical solutions and assessment of clinical usefulness of capsule endoscopy.

    Science.gov (United States)

    Koprowski, Robert

    2015-12-01

    The paper presents an overview of endoscopic capsules with particular emphasis on technical aspects. It indicates common problems in capsule endoscopy such as: (1) limited wireless communication (2) the use of capsule endoscopy in the case of partial patency of the gastrointestinal tract, (3) limited imaging area, (4) external capsule control limitations. It also presents the prospects of capsule endoscopy, the most recent technical solutions for biopsy and the mobility of the capsule in the gastrointestinal tract. The paper shows the possibilities of increasing clinical usefulness of capsule endoscopy resulting from technological limitations. Attention has also been paid to the current role of capsule endoscopy in screening tests and the limitations of its effectiveness. The paper includes the author's recommendations concerning the direction of further research and the possibility of enhancing the scope of capsule endoscopy.

  4. Anterior cruciate ligament (ACL) injury -- aftercare

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000681.htm Anterior cruciate ligament (ACL) injury - aftercare To use the sharing features ... that connects a bone to another bone. The anterior cruciate ligament (ACL) is located inside your knee joint and ...

  5. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives.

    Science.gov (United States)

    Glass, Paul; Cheung, Eugene; Sitti, Metin

    2008-12-01

    This paper presents a new concept for an anchoring mechanism to enhance existing capsule endoscopes. The mechanism consists of three actuated legs with compliant feet lined with micropillar adhesives to be pressed into the intestine wall to anchor the device at a fixed location. These adhesive systems are inspired by gecko and beetle foot hairs. Single-leg and full capsule mathematical models of the forces generated by the legs are analyzed to understand capsule performance. Empirical friction models for the interaction of the adhesives with an intestinal substrate were experimentally determined in vitro using dry and oil-coated elastomer micropillar arrays with 140 microm pillar diameter, 105 microm spacing between pillars, and an aspect ratio of 1:1 on fresh porcine small intestine specimens. Capsule prototypes were also tested in a simulated intestine environment and compared with predicted peristaltic loads to assess the viability of the proposed design. The experimental results showed that a deployed 10 gr capsule robot can withstand axial peristaltic loads and anchor reliably when actuation forces are greater than 0.27 N using dry micropillars. Required actuation forces may be reduced significantly by using micropillars coated with a thin silicone oil layer.

  7. Controlled release from stimuli-sensitive microgel capsules

    Science.gov (United States)

    Masoud, Hassan; Alexeev, Alexander

    2011-10-01

    We introduce a mesoscale computational model for responsive gels, i.e. chemically cross-linked polymer networks immersed in Newtonian fluids, and use it to probe the release of nanoparticles from hollow microgel capsules that swell and deswell in response to external stimuli. Our model explicitly describes the transport of nanoparticles in swelling/deswelling polymer networks with complex geometries and associated fluid flows. Our simulations reveal that responsive microcapsules can be effectively utilized for steady and pulsatile release of encapsulated solutes. Steady, diffusive release of nanoparticle takes place from swollen gel capsules, whereas capsule deswelling cause burst-like discharge of solutes driven by a flow from the shrinking capsule interior. We demonstrate that this hydrodynamic release can be regulated by introducing rigid microscopic rods inside the capsule. Our calculations indicate that the rods stretch the deswelling membrane and promote the formation of large pores in the shell, which allow massive flow-driven release of nanoparticles. Thus, our findings unveil a new approach for regulating the release from stimulus responsive micro-carriers that will be especially useful for designing new drug delivery systems.

  8. A novel release mechanism from responsive microgel capsules

    Science.gov (United States)

    Masoud, Hassan; Alexeev, Alexander

    2011-11-01

    We use a mesoscale computational model for responsive gels to study the release of nanoparticles from hollow microcapsules. Our model explicitly describes the transport of nanoparticles in swelling/deswelling polymer networks with complex geometries and associated fluid flows. Our simulations show that capsule swelling results in a steady release of encapsulated nanoparticle, which is set by the ability of particles to diffuse through the capsule network. For deswelling capsules, we show that a fluid flow induced by capsule shrinking leads to rapid nanoparticle release. This release, however, is limited due to decreasing mesh size of the deswelling shell. We show that by introducing solid microrods inside deswelling capsules, we can control the rapid release. Our calculations reveal that the rods stretch the deswelling membrane and promote the formation of large pores in the shell, which allow massive flow-driven release of nanoparticles. Thus, our findings reveal a new approach for regulating the release from stimulus responsive micro-carriers that may be useful for designing new drug delivery systems. Financial support from the Donors of the PetroleumResearchFund, administered by theACS, is gratefully acknowledged.

  9. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  10. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  11. A modular and programmable development platform for capsule endoscopy system.

    Science.gov (United States)

    Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A

    2014-06-01

    The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.

  12. [Future prospects in digestive endoscopy: wireless capsule endoscopy].

    Science.gov (United States)

    Sacher-Huvelin, S; Bourreille, A; Le Rhun, M; Galmiche, J-P

    2009-01-01

    Since the beginning of the millennium, the development of wireless capsule endoscopy has represented a major technological advance. The capsule is ingested by the patient and images are transmitted via several sensors positioned on the skin of the patient and downloaded in a computer system. The first applications were focused on the exploration of the small bowel which was previously considered as an obscure area for conventional endoscopy. Wireless capsule endoscopy of the small bowel is now an established technique with many acknowledged indications for the diagnosis of obscure bleeding, anemia of presumed digestive origin, Crohn's disease and small bowel tumors. Recently, thanks to technological progresses, novel capsules have been developed for specific segments of the gut namely the oesophagus and the colon. Recent data suggest that these new capsules could have potential applications for the diagnosis of oesophageal varices, Barrett's oesophagus and for the screening and/or surveillance of polyps of the colon. However, further studies are required before such strategies could be approved for clinical use or even replace conventional endoscopic modalities. In the long-term, progresses in signal processing as well as in the miniaturisation of sensors or markers may lead to a new generation of endoscopic robots. This technological breakthrough may ultimately result in new concepts and change current practice of digestive endoscopy.

  13. Wireless powered capsule endoscopy for colon diagnosis and treatment.

    Science.gov (United States)

    Chen, Wenwen; Yan, Guozheng; He, Shu; Ke, Quan; Wang, Zhiwu; Liu, Hua; Jiang, Pingping

    2013-11-01

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro.

  14. Regional material properties of the human hip joint capsule ligaments.

    Science.gov (United States)

    Hewitt, J; Guilak, F; Glisson, R; Vail, T P

    2001-05-01

    The hip joint capsule functions to constrain translation between the femur and acetabulum while allowing rotational and planar movements. Despite the crucial role it plays in the pathogenesis of hip instability, little is known about its biomechanical properties. The goal of this study was to determine the regional material properties of the iliofemoral and ischiofemoral ligaments of the capsule. Ten human cadaveric specimens of each ligament were tested to failure in tension. The stress at failure, strain at failure, strain energy density at failure, toe- and linear-region elastic moduli, and the Poisson's ratio were measured for each ligament. The strain to failure was greatest in the ischiofemoral ligament, while no significant difference was noted in failure stress by region or ligament. The Young's moduli of elasticity ranged from 76.1 to 285.8 MPa among the different ligaments, and were generally consistent with properties previously reported for the shoulder capsule. The elastic moduli and strain energy density at failure differed by region. No significant differences in Poisson's ratio were found by region or ligament. The average Poisson's ratio was approximately 1.4, consistent with anisotropic behavior of ligamentous tissues. Understanding the material properties of the hip capsule may help the orthopaedic surgeon better understand normal ligament function, and thereby choose a surgical approach or strategy of repair. Furthermore, knowledge of the normal mechanical function of the hip capsule ligaments could assist in the evaluation of the success of a repair.

  15. Computer aided wireless capsule endoscopy video segmentation.

    Science.gov (United States)

    Li, Baopu; Xu, Guoqing; Zhou, Ran; Wang, Tianfu

    2015-02-01

    Wireless capsule endoscopy (WCE) opens a new door for the digestive tract examination and diagnosis. However, the examination of its video data is tedious. This study aims to assist a physician to interpret a WCE video by segmenting it into different anatomic parts in the digestive tract. A two level WCE video segmentation scheme is proposed to locate the boundary between the stomach, small intestine, and large intestine. In the rough level, the authors utilize color feature to draw a dissimilarity curve for a WCE video and obtain an approximate boundary. Meanwhile, training data for the fine level segmentation can be collected automatically between the two approximate boundaries of organs to overcome the difficulty of training data collection in traditional approaches. In the fine level, color histogram in the HSI color space is used to segment the stomach and small intestine. Then, color uniform local binary pattern (CULBP) algorithm is applied for discrimination of the small intestine and large intestine, which includes two patterns, namely, color norm and color angle pattern. The CULBP feature is robust to variation of illumination and discriminative for classification. In order to increase the performance of support vector machine, the authors integrate it with the Adaboost approach. Finally, the authors refine the classification results to segment a WCE video into different parts, that is, the stomach, small intestine, and large intestine. The average precision and recall are 91.2% and 90.6% for the stomach/small intestine classification, 89.2% and 88.7% for the small/large intestine discrimination. Paired t-test also demonstrates a significant better performance of the proposed scheme compared to some traditional methods. The average segmentation error is 8 frames for the stomach/small intestine discrimination, and 14 frames for the small/large intestine segmentation. The results have demonstrated that the new video segmentation method can accurately locate

  16. Anterior spinal cord syndrome of unknown etiology

    OpenAIRE

    Klakeel, Merrine; Thompson, Justin; Srinivasan, Rajashree; McDonald, Frank

    2015-01-01

    A spinal cord injury encompasses a physical insult to the spinal cord. In the case of anterior spinal cord syndrome, the insult is a vascular lesion at the anterior spinal artery. We present the cases of two 13-year-old boys with anterior spinal cord syndrome, along with a review of the anatomy and vasculature of the spinal cord and an explanation of how a lesion in the cord corresponds to anterior spinal cord syndrome.

  17. 38 CFR 3.379 - Anterior poliomyelitis.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  18. Epidermoid cyst in Anterior, Middle

    Directory of Open Access Journals (Sweden)

    Kankane Vivek Kumar

    2016-09-01

    Full Text Available Epidermoid cysts are benign slow growing more often extra-axial tumors that insinuate between brain structures, we present the clinical, imaging, and pathological findings in 35 years old female patients with atypical epidermoid cysts which was situated anterior, middle & posterior cranial fossa. NCCT head revealed hypodense lesion over right temporal and perisylvian region with extension in prepontine cistern with mass effect & midline shift and MRI findings revealed a non-enhancing heterogeneous signal intensity cystic lesion in right frontal & temporal region extending into prepontine cistern with restricted diffusion. Patient was detoriated in night of same day of admission, emergency Fronto-temporal craniotomy with anterior peterousectomy and subtotal resection was done. The histological examination confirms the epidermoid cyst. The timing of ectodermal tissue sequestration during fetal development may account for the occurrence of atypical epidermoid cysts.

  19. [Anterior chest wall examination reviewed].

    Science.gov (United States)

    Lo Monaco, A; Santilli, D; Trotta, F

    2002-01-01

    Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondyloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the "activity" of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  20. Chronic Anterior Uveitis in Children.

    Science.gov (United States)

    Couto, Cristóbal; Frick, Mercedes M; LaMattina, Kara; Schlaen, Ariel; Khoury, Marina; Lopez, Matilde María; Hurtado, Erika; Espada, Graciela

    2016-08-01

    To describe the visual prognosis and remission rate of chronic anterior uveitis in pediatric patients. A retrospective case series of children with chronic anterior uveitis treated in the University of Buenos Aires. Juvenile idiopathic arthritis was defined according to the International League of Associations for Rheumatology criteria. Uveitis remission was defined according to SUN criteria. There were 35 pediatric patients (61 eyes), mean age of uveitis onset was 7.69 ± 3 years, 60% were females and 74% had bilateral disease, median follow-up was 60 months (range: 12-192 months). JIA was more frequent in females (80.95 vs 21.43; pgood Received 30 August 2015; revised 6 March 2016; accepted 14 March 2016; published online 18 May 2016.

  1. Anterior cingulotomy for intractable pain

    Directory of Open Access Journals (Sweden)

    Nitin Agarwal, MD

    2016-12-01

    Full Text Available Conservative therapy is often the first-line treatment for many symptoms of various disease processes, including pain. Nevertheless, if pharmacological or medical management fails for those patients with severe and chronic pain, a surgical strategy may be a reasonable option. First performed for psychiatric disorders, cingulotomy now has been recognized as a viable option for the management of pain. The authors review the literature on anterior cingulotomy for intractable pain to provide guidelines for management and expected outcomes.

  2. Anterior shoulder dislocations in sports.

    Science.gov (United States)

    Aronen, J G

    1986-01-01

    Anterior shoulder dislocations, primary and recurrent, are among the most disabling injuries to the shoulder that can plague the athlete. The diagnosis is easily made by the following: the physical appearance of the shoulder; loss of capability by the athlete to internally and externally rotate the shoulder with the elbow at his side; by evaluating the mechanism of injury; and x-rays. Anterior shoulder dislocations should be reduced as soon as possible after diagnosis, to minimise the stretching effect on the neurovascular structures while the humeral head is dislocated. The reduction is not done to allow the athlete to return immediately to sport. Use of a simple traction method in the first 10 to 15 minutes following the injury will result in a successful reduction in the vast majority of dislocations. Reduction of the humeral head can be confirmed by the athlete regaining the capability to internally and externally rotate his shoulder with his elbow at his side. Following reduction, the athlete should begin a treatment regimen which includes a restrengthening programme emphasising the muscles of internal rotation and adduction plus rigid restrictions of activities until the goals of the rehabilitation programme are satisfied. The author's experience with this treatment regimen with athletes at the United States Naval Academy, has shown a decrease of the recurrence rate of primary anterior shoulder dislocations to 25% versus the 80% recurrence rate we have become familiar with from studies done which did not stress specific rehabilitation programmes. The athlete should also be instructed in a self-performed traction method for reduction should a redislocation occur, to minimise the stretching effect on the neurovascular structures and allow relief from discomfort. Surgery for primary and recurrent anterior dislocations should only be considered when the athlete fails to achieve the desired goals after participating in a specific, progressive, adequate

  3. Anterior chest wall examination reviewed

    OpenAIRE

    F. Trotta; D. Santilli; A. Lo Monaco

    2011-01-01

    Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as er...

  4. Experience with Hirschsprung's Disease at a Tertiary Hospital in ...

    African Journals Online (AJOL)

    21 (5%), cardiac (2%), and a combination (2%) of Down's syndrome with cardiac, anterior abdominal wall defects, paraesophageal hernia, congenital cataract, phimosis, hydrocele and renal agenesis. Other (6%) anomalies recorded were: phimosis, hydrocele, ambiguous genitalia, renal agenesis and prune belly syndrome ...

  5. Sensitive Detection of Deliquescent Bacterial Capsules through Nanomechanical Analysis.

    Science.gov (United States)

    Nguyen, Song Ha; Webb, Hayden K

    2015-10-20

    Encapsulated bacteria usually exhibit strong resistance to a wide range of sterilization methods, and are often virulent. Early detection of encapsulation can be crucial in microbial pathology. This work demonstrates a fast and sensitive method for the detection of encapsulated bacterial cells. Nanoindentation force measurements were used to confirm the presence of deliquescent bacterial capsules surrounding bacterial cells. Force/distance approach curves contained characteristic linear-nonlinear-linear domains, indicating cocompression of the capsular layer and cell, indentation of the capsule, and compression of the cell alone. This is a sensitive method for the detection and verification of the encapsulation status of bacterial cells. Given that this method was successful in detecting the nanomechanical properties of two different layers of cell material, i.e. distinguishing between the capsule and the remainder of the cell, further development may potentially lead to the ability to analyze even thinner cellular layers, e.g. lipid bilayers.

  6. Adhesive capsulitis and dynamic splinting: a controlled, cohort study

    Science.gov (United States)

    Gaspar, Paul D; Willis, F Buck

    2009-01-01

    Background Adhesive Capsulitis (AC) affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in contracture reduction from pathologies including Trismus to plantar fasciitis. The purpose of this study was to examine the efficacy of dynamic splinting on patients with AC. Methods This controlled, cohort study, was conducted at four physical therapy, sports medicine clinics in Texas and California. Sixty-two patients diagnosed with Stage II Adhesive Capsulitis were grouped by intervention. The intervention categories were as follows: Group I (Control); Group II (Physical Therapy exclusively with standardized protocols); Group III; (Shoulder Dynasplint system exclusively); Group IV (Combined treatment with Shoulder Dynasplint and standardized Physical Therapy). The duration of this study was 90 days for all groups, and the main outcome measures were change in active, external rotation. Results Significant difference was found for all treatment groups (p adhesive Capsulitis. Trial Registration Trial Number: NCT00873158 PMID:19735563

  7. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  8. Evaluation of hard gelatin capsules and hydroxypropyl methylcellulose containing ampicillin

    Directory of Open Access Journals (Sweden)

    Graziella Gonçalves Weigert

    2012-01-01

    Full Text Available This study aims to develop and evaluate formulations containing ampicillin in capsules of gelatin and hydroxypropyl methylcellulose (HPMC. Two formulations (A and B were developed. The final product quality was evaluated by testing for quality control and the results were in agreement with the Brazilian Pharmacopoeia. The formulations with HPMC capsules showed lower percentages of drug dissolved (99.67%, HPMC-A and 87.70%, HPMC-B than the gelatin (100.18%, GEL-A and 101.16% GEL-B. Because of the delay of the ampicillin release observed in the dissolution profiles, it becomes necessary to evaluate the drugs that can be conditioned in the HPMC capsules.

  9. Validating Inertial Confinement Fusion (ICF) predictive capability using perturbed capsules

    Science.gov (United States)

    Schmitt, Mark; Magelssen, Glenn; Tregillis, Ian; Hsu, Scott; Bradley, Paul; Dodd, Evan; Cobble, James; Flippo, Kirk; Offerman, Dustin; Obrey, Kimberly; Wang, Yi-Ming; Watt, Robert; Wilke, Mark; Wysocki, Frederick; Batha, Steven

    2009-11-01

    Achieving ignition on NIF is a monumental step on the path toward utilizing fusion as a controlled energy source. Obtaining robust ignition requires accurate ICF models to predict the degradation of ignition caused by heterogeneities in capsule construction and irradiation. LANL has embarked on a project to induce controlled defects in capsules to validate our ability to predict their effects on fusion burn. These efforts include the validation of feature-driven hydrodynamics and mix in a convergent geometry. This capability is needed to determine the performance of capsules imploded under less-than-optimum conditions on future IFE facilities. LANL's recently initiated Defect Implosion Experiments (DIME) conducted at Rochester's Omega facility are providing input for these efforts. Recent simulation and experimental results will be shown.

  10. Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract

    Science.gov (United States)

    Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay

    2011-03-01

    Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.

  11. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Science.gov (United States)

    Pan, Guobing; Wang, Litong

    2012-01-01

    Wireless capsule endoscopy (WCE) offers a feasible noninvasive way to detect the whole gastrointestinal (GI) tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE) is the bottleneck. Wireless power transmission (WPT) is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed. PMID:22253621

  12. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Science.gov (United States)

    Caboni, Mariaelena; Pédron, Thierry; Rossi, Omar; Goulding, David; Pickard, Derek; Citiulo, Francesco; MacLennan, Calman A; Dougan, Gordon; Thomson, Nicholas R; Saul, Allan; Sansonetti, Philippe J; Gerke, Christiane

    2015-03-01

    Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg) of the lipopolysaccharide (LPS) plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  13. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Directory of Open Access Journals (Sweden)

    Mariaelena Caboni

    2015-03-01

    Full Text Available Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg of the lipopolysaccharide (LPS plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  14. Shoulder activity level in patients with idiopathic adhesive capsulitis.

    Science.gov (United States)

    Lamplot, Joseph D; Lillegraven, Olivia; Brophy, Robert H

    2017-09-01

    Idiopathic adhesive capsulitis is a common condition resulting in painful multidirectional restriction of motion. Adhesive capsulitis may inhibit shoulder activity level, but this relationship has not been previously studied. This study tested the hypothesis that patients with idiopathic adhesive capsulitis have lower shoulder activity than sex- and age-matched controls. Seventy-two eligible patients (37 men and 35 women) with idiopathic adhesive capsulitis completed a validated shoulder activity scale that was compared with sex- and age-matched norms from a healthy population with no history of shoulder disorders. The association of shoulder activity level with patient age, sex, and American Shoulder and Elbow Surgeons and Simple Shoulder Test (SST) scores was evaluated. Overall, 58% of patients actually had higher shoulder activity scores than sex- and age-matched controls. Among patients aged 51 to 70 years, 68% of patients (73% of men and 63% of women) demonstrated higher Shoulder Activity Scale scores compared with controls. The activity level was higher among all patients aged 51 to 70 years compared with controls (10.3 ± 1.48 vs. 8 ± 0.52, P = .0067). The difference was significant for men in this age group (12.2 ± 1.7 vs. 9 ± 0.75, P = .0042). There was a statistically significant positive correlation of the Shoulder Activity Scale score with the SST score (r = 0.31, P = .009). Patients with idiopathic adhesive capsulitis do not have a lower shoulder activity level than sex- and age-matched controls, and older men may actually have a higher level of shoulder activity than controls. Shoulder activity level is correlated with the SST score in patients with idiopathic adhesive capsulitis. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. First beryllium capsule implosions on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2016-05-15

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  16. Factors affecting capsule size and production by lactic acid bacteria used as dairy starter cultures.

    Science.gov (United States)

    Hassan, A N; Frank, J F; Shalabi, S I

    2001-02-28

    The effects of sugar substrates on capsule size and production by some capsule-forming nonropy and ropy dairy starter cultures were studied. Test sugars (glucose, lactose, galactose, or sucrose) were used as a sole carbohydrate source and the presence of a capsule and its size were determined by using confocal scanning laser microscopy. Nonropy strains produced maximum capsule size when grown in milk. Strains that did not produce capsules in milk did not produce them in any other growth medium. Specific sugars required for capsule production were strain-dependent. Increasing lactose content of Elliker broth from 0.5 to 5% or adding whey protein or casein digest produced larger capsules. Whey protein concentrate stimulated production of larger capsules than did casamino acids or casitone. Some Streptococcus thermophilus strains produced capsules when grown on galactose only. Nonropy strains of Lactobacillus delbrueckii subsp. bulgaricus produced capsules on lactose, but not on glucose. A ropy strain of Lactobacillus delbrueckii subsp. bulgaricus produced a constant capsule size regardless of the growth medium. The ability of some strains of Streptococcus thermophilus to use galactose in capsule production could reduce browning of mozzarella cheese during baking by removing a source of reducing sugar. Media that do not support capsule production may improve cell harvesting.

  17. Preshot Predictions for Defect Induced Mix (DIME) Capsules

    International Nuclear Information System (INIS)

    Bradley, Paul A.; Krasheninnikova, Natalia S.; Tregillis, Ian L.; Schmitt, Mark J.

    2012-01-01

    In this memo, we evaluate the most probable yield and other results for the Defect Induced Mix (DIME-12A) Polar Direct Drive (PDD) capsule-only shots. We evaluate the expected yield, bang time, burn averaged ion temperature, and the average electron temperature of the Ge line-emitting region. We also include synthetic images of the capsule backlit by Cu K-α emission (8.39 keV) and core self-emission synthetic images. This memo is a companion to the maximum credible yield memo (LA-UR--12-00287) published earlier.

  18. Preshot Predictions for Defect Induced Mix (DIME) Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, Paul A. [Los Alamos National Laboratory; Krasheninnikova, Natalia S. [Los Alamos National Laboratory; Tregillis, Ian L. [Los Alamos National Laboratory; Schmitt, Mark J. [Los Alamos National Laboratory

    2012-07-31

    In this memo, we evaluate the most probable yield and other results for the Defect Induced Mix (DIME-12A) Polar Direct Drive (PDD) capsule-only shots. We evaluate the expected yield, bang time, burn averaged ion temperature, and the average electron temperature of the Ge line-emitting region. We also include synthetic images of the capsule backlit by Cu K-{alpha} emission (8.39 keV) and core self-emission synthetic images. This memo is a companion to the maximum credible yield memo (LA-UR-12-00287) published earlier.

  19. Symptomatic retention of the Agile® patency capsule.

    Science.gov (United States)

    Egea Valenzuela, Juan; Estrella Díez, Esther; Alberca de Las Parras, Fernando

    2017-06-01

    The Agile® capsule has shown to be useful when evaluating the patency of the small bowel in patients prior to capsule endoscopy studies. It is a safe tool and a low rate of complications have been reported, highlighting symptomatic retention, although references in literature are scarce and it is only observed in 1.2% of the procedures. We present the case of a symptomatic retention of this device in a patient with previously known colonic Crohn's disease in who a small bowel study was indicated and was sent for prior patency test.

  20. Data package for the Turkey Point material interaction test capsules

    International Nuclear Information System (INIS)

    Krogness, J.C.; Davis, R.B.

    1979-01-01

    Objective of the Materials Interaction Test (MIT) is to obtain interaction information on candidate package storage materials and geologies under prototypic temperatures in gamma and low level neutron fields. Compatibility, structural properties, and chemical transformations will be studied. The multiple test samples are contained within test capsules connected end-to-end to form a test train. Only passive instrumentation has been used to monitor temperatures and record neutron fluence. The test train contains seven capsules: three to test compatibility, two for structural tests, and two for chemical transformation studies. The materials tested are potential candidates for the spent fuel package canister and repository geologies

  1. Welding iridium heat-source capsules for space missions

    International Nuclear Information System (INIS)

    Kanne, W.R. Jr.

    1982-03-01

    A remote computer-controlled welding station was developed to encapsulate radioactive PuO 2 in iridium. Weld quench cracking caused an interruption in production of capsules for upcoming space missions. Hot crack sensitivity of the DOP-26 iridium alloy was associated with low melting constituents in the grain boundaries. The extent of cracking was reduced but could not be eliminated by changes to the welding operation. An ultrasonic test was developed to detect underbead cracks exceeding a threshold size. Production was continued using the ultrasonic test to reject capsules with detectable cracks

  2. Colon capsule endoscopy: Current status and future directions

    Science.gov (United States)

    Tal, Andrea O; Vermehren, Johannes; Albert, Jörg G

    2014-01-01

    Colon capsule endoscopy (CCE; PillCam Colon; Given Imaging; Yoqneam, Israel) is a minimally invasive wireless technique for the visualization of the colon. With the recent introduction of the second generation colon capsule the diagnostic accuracy of CCE for polyp detection has significantly improved and preliminary data suggest it may be useful to monitor mucosal inflammation in patients with inflammatory bowel disease. Limitations include the inability to take biopsies and the procedural costs. However, given the potentially higher acceptance within an average risk colorectal cancer (CRC) screening population, its usefulness as a screening tool with regard to CRC prevention should be further evaluated. PMID:25469027

  3. Wireless endoscopy in 2020: Will it still be a capsule?

    Science.gov (United States)

    Koulaouzidis, Anastasios; Iakovidis, Dimitris K; Karargyris, Alexandros; Rondonotti, Emanuele

    2015-05-07

    Currently, the major problem of all existing commercial capsule devices is the lack of control of movement. In the future, with an interface application, the clinician will be able to stop and direct the device into points of interest for detailed inspection/diagnosis, and therapy delivery. This editorial presents current commercially-available new designs, European projects and delivery capsule and gives an overview of the progress required and progress that will be achieved -according to the opinion of the authors- in the next 5 year leading to 2020.

  4. Advances in pediatric gastroenterology: introducing video camera capsule endoscopy.

    Science.gov (United States)

    Siaw, Emmanuel O

    2006-04-01

    The video camera capsule endoscope is a gastrointestinal endoscope approved by the U.S. Food and Drug Administration in 2001 for use in diagnosing gastrointestinal disorders in adults. In 2003, the agency approved the device for use in children ages 10 and older, and the endoscope is currently in use at Arkansas Children's Hospital. A capsule camera, lens, battery, transmitter and antenna together record images of the small intestine as the endoscope makes its way through the bowel. The instrument is used with minimal risk to the patient while offering a high degree of accuracy in diagnosing small intestine disorders.

  5. Sub-Scale Re-entry Capsule Drop via High Altitude Balloons

    Data.gov (United States)

    National Aeronautics and Space Administration — The project objective is to develop and test a sub-scale version of the Maraia Entry Capsule on a high altitude balloon. The capsule is released at 100,000 ft. The...

  6. Self collision avoidance for humanoids using circular and elliptical capsule bounding volumes

    CSIR Research Space (South Africa)

    Dube, C

    2013-09-01

    Full Text Available This paper presents a self collision avoidance scheme for humanoid robots using elliptical and circular capsules as collision bounding volumes. A capsule is defined as an elliptical or circular cylinder capped with ellipsoids or spheres respectively...

  7. Model of the humanoid body for self collision detection based on elliptical capsules

    CSIR Research Space (South Africa)

    Dube, C

    2011-12-01

    Full Text Available This paper presents a self collision detection scheme for humanoid robots using elliptical and circular capsules as bounding volumes. A capsule is defined as an elliptical or circular cylinder capped with ellipsoids or spheres respectively...

  8. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  9. Correlations between ventricular enlargement and gray and white matter volumes of cortex, thalamus, striatum, and internal capsule in schizophrenia.

    Science.gov (United States)

    Horga, Guillermo; Bernacer, Javier; Dusi, Nicola; Entis, Jonathan; Chu, Kingwai; Hazlett, Erin A; Haznedar, M Mehmet; Kemether, Eileen; Byne, William; Buchsbaum, Monte S

    2011-10-01

    Ventricular enlargement is one of the most consistent abnormal structural brain findings in schizophrenia and has been used to infer brain shrinkage. However, whether ventricular enlargement is related to local overlying cortex and/or adjacent subcortical structures or whether it is related to brain volume change globally has not been assessed. We systematically assessed interrelations of ventricular volumes with gray and white matter volumes of 40 Brodmann areas (BAs), the thalamus and its medial dorsal nucleus and pulvinar, the internal capsule, caudate and putamen. We acquired structural MRI ( patients with schizophrenia (n = 64) and healthy controls (n = 56)) and diffusion tensor fractional anisotropy (FA) (untreated schizophrenia n = 19, controls n = 32). Volumes were assessed by manual tracing of central structures and a semi-automated parcellation of BAs. Patients with schizophrenia had increased ventricular size associated with decreased cortical gray matter volumes widely across the brain; a similar but less pronounced pattern was seen in normal controls; local correlations (e.g. temporal horn with temporal lobe volume) were not appreciably higher than non-local correlations (e.g. temporal horn with prefrontal volume). White matter regions adjacent to the ventricles similarly did not reveal strong regional relationships. FA and center of mass of the anterior limb of the internal capsule also appeared differentially influenced by ventricular volume but findings were similarly not regional. Taken together, these findings indicate that ventricular enlargement is globally interrelated with gray matter volume diminution but not directly correlated with volume loss in the immediately adjacent caudate, putamen, or internal capsule.

  10. Resin Capsules: Permeable Containers for Parallel/Combinatorial Solid-Phase Organic Synthesis

    OpenAIRE

    Bouillon, Isabelle; Soural, Miroslav; Krchňák, Viktor

    2008-01-01

    A resin capsule is a permeable container for resin beads designed for multiple/combinatorial solid-phase organic synthesis. Resin capsules consist of a high density polyethylene ring sealed with peek mesh on both sides. The cylindrical shape of resin capsules enabled space-saving packing into plastic column-like reaction vessels commonly used for solid-phase organic synthesis. Resin capsules have been evaluated for their use in combinatorial synthesis, and a set of model compounds with excell...

  11. A simple method for preparing radioactive capsules in colon transit study

    International Nuclear Information System (INIS)

    Wang Shyhjen; Lin Wanyu; Tsai Shihchuan; Chen Granhun

    2000-01-01

    Colon transit study is currently performed by delivering technetium-99m or indium-111 labelled activated charcoal to the colon in a methacrylate-coated capsule (coated capsule). However, the coating procedure is complicated and methacrylate has not been approved by the Food and Drug Administration. Therefore, a simpler method is needed for the clinical routine use of colon transit study. In this study, we used a commercial empty enteric capsule and a coated capsule for the measurement of colon transit time. We compared the in vitro stability and in vivo scintigraphy of 99m Tc-labelled activated charcoal in the coated capsule and the enteric capsule to evaluate the possibility of clinical usage of the enteric capsule for colon transit time study. Activated charcoal powder was mixed with 99m Tc-diethylene triamine penta-acetic acid (DTPA) and vaporized to dryness. The dry 99m Tc-DTPA activated charcoal was loaded into the coated capsule and the enteric capsule. In vitro stability study was performed by immersing these capsules in a colourless buffer of variable pH which mimicked the conditions in the stomach and the small bowel. Capsule disruption was determined. Colon transit scintigraphy with 99m Tc-DTPA charcoal was performed in five normal volunteers using these two capsules. The in vitro stability of these two types of capsule was similar and the colon transit scintigraphy findings were almost identical. Most capsules dissolved in the ascending colon and very few in the terminal ileum. It is concluded that enteric capsule is a suitable alternative to coated capsule for measurement of colon transit. (orig.)

  12. A Pilot Trial of Ambulatory Monitoring of Gastric Motility Using a Modified Magnetic Capsule Endoscope

    OpenAIRE

    Kim, Hee Man; Choi, Ja Sung; Cho, Jae Hee

    2014-01-01

    The magnetic capsule endoscope has been modified to be fixed inside the stomach and to monitor the gastric motility. This pilot trial was designed to investigate the feasibility of the magnetic capsule endoscope for monitoring gastric motility. The magnetic capsule endoscope was swallowed by the healthy volunteer and maneuvered by the external magnet on his abdomen surface inside the stomach. The magnetic capsule endoscope transmitted image of gastric peristalsis. This simple trial suggested ...

  13. Metabolic patterns of the shoulder joint on (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in adhesive capsulitis.

    Science.gov (United States)

    Kim, Du Hwan; Sung, Duk Hyun; Ga, Hyo Yun; Choi, Joon Young

    2014-02-01

    The purpose of our study was to demonstrate metabolic patterns on (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in patients with adhesive capsulitis (AC). We retrospectively reviewed (18)F-FDG PET/CT performed on 22 shoulders of 21 patients diagnosed with AC: 2 shoulders with stage I, 14 with stage II, and 6 with stage III. A clinical diagnosis of AC was retrospectively made based on clinical examination, clinical course, and imaging. The pattern of radiotracer uptake was analyzed. Standardized uptake values in rotator interval (RI), anterior joint capsule (AJC), axillary recess (AR), and greater tuberosity were measured and compared to those of the contralateral side and the control group consisting of 40 shoulders in 20 subjects without shoulder pain. Four patterns of uptake were noted: (1) glenoid type I (n = 16), with uptake in RI, AJC, and AR; (2) glenoid type II (n = 2),with uptake in AJC and AR; (3) glenoid type III (n = 2), with uptake in RI and AJC; (4) focal type (n = 2), with uptake in RI or AR. Affected side SUVmax for RI, AJC, and AR was significantly higher compared with the unaffected side and the control group. Two shoulders with stage I AC had patterns similar to the ones with stage II or III. Specific patterns of (18)F-FDG uptake with dominant uptake in RI, AJC, or AR may be related to AC.

  14. Anterior vs Posterior Periarticular Multimodal Drug Injections: A Randomized, Controlled Trial in Simultaneous Bilateral Total Knee Arthroplasty.

    Science.gov (United States)

    Laoruengthana, Artit; Rattanaprichavej, Piti; Rasamimongkol, Supachok; Galassi, Monton

    2017-07-01

    Currently, various techniques are used to overcome postoperative pain after total knee arthroplasty. A local analgesic infiltration with periarticular multimodal drug injection (PMDI) is favorable because of its simplicity, safety, and efficacy. The present study compared the efficacy of a PMDI at the anterior vs posterior compartments. Forty-six patients were randomized to receive the PMDI at either the anterior or posterior compartment, with the contralateral knee receiving the PMDI at the opposite compartment. The PMDI injected to the posterior capsule, medial and lateral meniscal remnant, was defined as the posterior compartment injection, whereas the injection to the medial retinaculum, quadriceps muscle, pes anserinus, and retropatellar fat pad was defined as the anterior compartment injection. Pain scores at rest, knee flexion angle, quadriceps function, and drainage blood loss were evaluated in both groups. The anterior PMDI group had significantly lower pain scores at rest during 96 hours postoperatively. On the day of discharge, 19 patients (41.3%) favored the knee with the anterior PMDI, which was superior to 9 patients (19.6%) who favored the knee with the posterior PMDI. The anterior PMDI demonstrated a superior recovery of quadriceps function during the same period, but there was no significant difference in terms of other parameters. The PMDI at the anterior compartment can reduce pain after total knee arthroplasty with potentially better quadriceps function compared with that in the PMDI at the posterior compartment. We recommend infiltrating the anterior compartment with a greater amount of PMDI than the posterior compartment. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Localization of orofacial representation in the corona radiata, internal capsule and cerebral peduncle in Macaca mulatta.

    Science.gov (United States)

    Morecraft, R J; Binneboese, A; Stilwell-Morecraft, K S; Ge, J

    2017-11-01

    Subcortical white matter injury is often accompanied by orofacial motor dysfunction, but little is known about the structural substrates accounting for these common neurological deficits. We studied the trajectory of the corticobulbar projection from the orofacial region of the primary (M1), ventrolateral (LPMCv), supplementary (M2), rostral cingulate (M3) and caudal cingulate (M4) motor regions through the corona radiata (CR), internal capsule (IC) and crus cerebri of the cerebral peduncle (ccCP). In the CR each pathway was segregated. Medial motor area fibers (M2/M3/M4) arched over the caudate and lateral motor area fibers (M1/LPMCv) curved over the putamen. At superior IC levels, the pathways were widespread, involving the anterior limb, genu and posterior limb with the M3 projection located anteriorly, followed posteriorly by projections from M2, LPMCv, M4 and M1, respectively. Inferiorly, all pathways maintained this orientation but shifted posteriorly, with adjacent fiber bundles overlapping minimally. In the ccCP, M3 fibers were located medially and M1 fibers centromedially, with M2, LPMCv, and M4 pathways overlapping in between. Finally, at inferior ccCP levels, all pathways overlapped. Following CR and superior IC lesions, the dispersed pathway distribution may correlate with acute orofacial dysfunction with spared pathways contributing to orofacial motor recovery. In contrast, the gradually commixed nature of pathway representation inferiorly may enhance fiber vulnerability and correlate with severe, prolonged deficits following lower subcortical and midbrain injury. Additionally, in humans these findings may assist in interpreting orofacial movements evoked during deep brain stimulation, and neuroimaging tractography efforts to localize descending orofacial motor pathways. © 2017 Wiley Periodicals, Inc.

  16. Iris-claw intraocular lenses to correct aphakia in the absence of capsule support.

    Science.gov (United States)

    De Silva, Samantha R; Arun, Kikkeri; Anandan, Maghizh; Glover, Nicholas; Patel, Chetan K; Rosen, Paul

    2011-09-01

    To evaluate the indications, postoperative visual efficacy, and complication rate after intraocular implantation of an iris-claw aphakic intraocular lens (IOL). Oxford Eye Hospital, Oxford, United Kingdom. Case series. This chart review comprised eyes with no capsule support that had anterior iris-fixation IOL implantation for aphakia between 2001 and 2009. The study comprised 116 eyes (104 patients). Iris-claw IOLs were inserted during primary lens surgery in 18 eyes (15.5%), during an IOL exchange procedure for dislocated posterior chamber IOLs in 19 eyes (16.4%), and as a secondary procedure in 79 eyes (68.1%). The mean follow-up was 22.4 months (range 3 to 79 months). The final corrected distance visual acuity (CDVA) was 6/12 or better in 68.9% of all eyes and in 47 of 53 eyes (88.7%) with no preoperative comorbidity. Complications included wound leak requiring resuturing in 2.6% of eyes, postoperative intraocular pressure rise in 9.5% of eyes (glaucoma escalation 0.8%), and cystoid macular edema in 7.7% of eyes (0.8% chronic). Iris-claw IOL subluxation occurred in 6.0% of eyes from 5 days to 60 months postoperatively; all the IOLs were repositioned. Corneal decompensation occurred in 1.7% of eyes; 0.8% had retinal detachments. Iris-claw IOL implantation for aphakia gave a good visual outcome and can be used for a wide range of indications. Postoperative complication rates were comparable to, if not better than, those with conventional anterior chamber IOLs. Correct implantation technique is critical in avoiding postoperative IOL subluxation. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Gnathostomiasis of the anterior chamber

    Directory of Open Access Journals (Sweden)

    Barua P

    2007-01-01

    Full Text Available Ocular involvement with Gnathostoma spinigerum occurs years after the initial infection that is acquired by ingestion of poorly cooked, pickled seafood or water contaminated with third stage larvae. Here we report a case of gnathostomiasis of the left eye of a 32-year-old lady hailing from Meghalaya, India. Her vision had deteriorated to hand movement. Slit lamp examination revealed a live, actively motile worm in the anterior chamber, which was extracted by supra temporal limbal incision and visual acuity was restored.

  18. Trismus as manifestation of bilateral internal capsule genu infarction

    NARCIS (Netherlands)

    Aries, M.J.H.; Vroomen, Patrick C. A. J.; van der Hoeven, Johannes H.; De Keyser, Jacques

    Acute trismus can have different causes. We describe the presentation, course and radiological findings of a 34-year-old man who developed acute trismus and MRI findings consistent with the combination of an old and fresh infarction in the genu of the internal capsule. We believe it is important to

  19. Langmuir and Langmuir-Blodgett films of capsules of haemoglobin ...

    Indian Academy of Sciences (India)

    Organized assemblies of capsules of haemoglobin (Hb), in the size range of 0.1 to 0.3 in Langmuir films have been studied at air/water interface below and above the isoelectric point. Spread films of these organizates suggest that there is no expulsion of individual particles or particle assemblies at the interface and the ...

  20. Langmuir and Langmuir–Blodgett films of capsules of haemoglobin ...

    Indian Academy of Sciences (India)

    Abstract. Organized assemblies of capsules of haemoglobin (Hb), in the size range of 0.1 to 0.3 μ in Lang- muir films have been studied at air/water interface below and above the isoelectric point. Spread films of these organizates suggest that there is no expulsion of individual particles or particle assemblies at the interface ...

  1. Adhesive capsulitis: role of MR imaging in differential diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Connell, David; Padmanabhan, Ravi; Buchbinder, Rachelle [Department of MRI, St. Frances Xavier Cabrini Hospital, 183 Wattletree Road, Malvern, Victoria 3144 (Australia)

    2002-08-01

    The purpose of this study was to describe and characterize the MR imaging findings in a group of patients who underwent surgery for adhesive capsulitis. Twenty-four MR imaging studies in 24 consecutive patients with clinical evidence of adhesive capsulitis were performed prior to arthroscopic capsulotomy. There were 17 women and 7 men with a mean age of 53.5 years. Images were scrutinised for changes in the synovium particularly in the rotator interval, around the biceps anchor and axillary pouch. Intravenous gadolinium was given routinely. We also examined a control group of 22 patients who underwent the same MR imaging protocol after referral for rotator cuff pathology. Soft tissue density showing variable enhancement after gadolinium administration was visible in the rotator interval in 22 of 24 studies on MR imaging. Seventeen patients showed soft tissue density partially encasing the biceps anchor. Ten patients showed thickening and gadolinium enhancement of the axillary pouch. Three patients from the study cohort had partial tears of the supraspinatus tendon. All the patients subsequently had surgery which confirmed fibrovascular scar tissue in the rotator interval, around the biceps anchor and a variable degree of synovial inflammation of the glenohumeral capsule. Two patients from a control group with suspected rotator cuff pathology showed abnormal intensity in the rotator interval on MR imaging. Magnetic resonance imaging can identify changes in the shoulder joint that correspond to abnormalities seen at surgery. This may be useful for discriminating adhesive capsulitis from other causes of shoulder pain. (orig.)

  2. Regional gastrointestinal contractility parameters using the wireless motility capsule

    DEFF Research Database (Denmark)

    Farmer, A D; Wegeberg, A-M L; Brock, B

    2018-01-01

    BACKGROUND: The wireless motility capsule concurrently measures temperature, pH and pressure as it traverses the gastrointestinal tract. AIMS: To describe normative values for motility/contractility parameters across age, gender and testing centres. METHODS: Healthy participants underwent a stand...

  3. Are Social Networking Websites Educational? Information Capsule. Volume 0909

    Science.gov (United States)

    Blazer, Christie

    2009-01-01

    More and more school districts across the country are joining social networking sites, such as Facebook and MySpace. This Information Capsule discusses the frequency with which school districts are using social networking sites, how districts are using the sites, and potential drawbacks associated with their use. Issues for districts to consider…

  4. Computer-Based Assessments. Information Capsule. Volume 0918

    Science.gov (United States)

    Blazer, Christie

    2010-01-01

    This Information Capsule reviews research conducted on computer-based assessments. Advantages and disadvantages associated with computer-based testing programs are summarized and research on the comparability of computer-based and paper-and-pencil assessments is reviewed. Overall, studies suggest that for most students, there are few if any…

  5. Characterization and identification of suspected counterfeit miltefosine capsules

    NARCIS (Netherlands)

    Dorlo, Thomas P. C.; Eggelte, Teunis A.; de Vries, Peter J.; Beijnen, Jos H.

    2012-01-01

    Recently, it was revealed that generic miltefosine capsules for the treatment of visceral leishmaniasis, a fatal parasitic disease, were possibly counterfeit products. Here we report on the methods to characterize and identify miltefosine in pharmaceutical products and the procedures that were used

  6. Conservative integrated treatment of adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Russo, Adriano; Arrighi, Annalisa; Vignale, Luigi; Molfetta, Luigi

    2014-01-01

    the aim of this study was to present the results of a conservative treatment for adhesive capsulitis based on an original protocol of combined pharmacological and rehabilitation treatment. fifty-two patients with idiopathic adhesive capsulitis were enrolled in the present study. The treatment protocol included the use of hyaluronic acid and anaesthetic periarticular and intra-articular injections followed by a specific program of capsule and muscle stretching. the results of this treatment showed complete recovery of range of motion (ROM) in 50 of the 52 cases. The mean pre-treatment ROM values were: 85° for forward elevation, 75° for abduction, 25° for external rotation, and 15° for internal rotation. The post-treatment mean ROM values showed marked improvements: 175° for forward elevation, 175° for abduction, 87.5° for external rotation and 75° for internal rotation. conservative treatment of adhesive capsulitis based on a combined pharmacological and rehabilitation approach was found to be effective in resolving pain and stiffness in 96% of the patients. level IV, therapeutic case series.

  7. Assessment of colorectal length using the electromagnetic capsule tracking system

    DEFF Research Database (Denmark)

    Mark, E B; Poulsen, J L; Haase, A M

    2017-01-01

    AIM: We aimed to determine colorectal length with the 3D-Transit system by describing a 'centerline' of capsule movement and compare it to known anatomy, as determined by magnetic resonance imaging (MRI). Further, we aimed to test the day-to-day variation of colorectal length assessed with the sy...

  8. Anion binding in covalent and self-assembled molecular capsules.

    Science.gov (United States)

    Ballester, Pablo

    2010-10-01

    This critical review describes selected examples extracted from the extensive literature generated during the past 42 years on the topic of anion binding in molecular capsules. The goal of including anions in molecular capsules emerges from the idea of incorporating the traits exhibited by biological receptors into synthetic ones. At the outset of this research area the capsules were unimolecular. The scaffold of the receptor was designed to covalently link a series of functional groups that could converge into a cavity and to avoid its collapse. The initial examples involved the encapsulation of one monoatomic spherical anion. With time, the cavity size of the receptor was increased and encapsulation of polyatomic anions and co-encapsulation became a reality. Synthetic economy fueled the use of aggregates of self-complementary molecules rather than one large molecule as capsules. The main purpose of this review is to give a general overview of the topic which might be of interest to supramolecular or non supramolecular chemists alike (149 references).

  9. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    structure, responsive to microwave electromagnetic radiation, is attached to a first wall portion of the capsule wall structure which comprises a lossy dielectric material. At least a predetermined segment of the first wall portion is heated by received microwave electromagnetic radiation to trigger...

  10. A magnetically actuated anchoring system for a wireless endoscopic capsule.

    Science.gov (United States)

    Zhou, Hao; Alici, Gursel; Munoz, Fredy

    2016-12-01

    In this study, we propose a new magnetically actuated anchoring system for wireless capsule endoscopes (WCE) by employing the principle of a switchable magnetic spring. A force model is derived to predict the magnetic force needed to support the interaction between the anchors and the intestinal lumen. The theoretical and experimental analysis conducted shows that the magnetic spring is capable of providing the force needed to activate the anchoring mechanism, which consists of four foldable legs. A prototype capsule with a size comparable with the size of a commercial WCE was designed, fabricated, and tested. The in-vitro tests with a real small intestine show that the proposed anchoring mechanism is able to raise the friction force between the anchoring legs and inner wall of the intestine by more than two times after its activation using an external magnetic field. Experimental results presented demonstrate that the proposed anchoring system, which has a low foot-print not taking up too much space on the capsule, can provide a reliable anchoring capability with the capsule inside the intestinal lumen.

  11. Watermelon stomach seen by wireless‐capsule endoscopy

    OpenAIRE

    MASCARENHAS‐SARAIVA, M.; LOPES, L.; MASCARENHAS‐SARAIVA, A.

    2003-01-01

    Endoscopy. 2003 Jan;35(1):100. Watermelon stomach seen by wireless-capsule endoscopy. Mascarenhas-Saraiva M, Lopes L, Mascarenhas-Saraiva A. SourceDigestive Endoscopy and Motility Unit, Trindade Hospital, Rua Trinidade 115, 4000-541 Porto, Portugal. PMID:12510242[PubMed - indexed for MEDLINE

  12. Fuel capsule HRB-21 postirradiation examination data report

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, C A; Bell, G L; Emerson, L C [and others

    1995-04-01

    HRB-21 was carried out in HFIR to demonstrate the performance capability of reference Nuclear Energy Modular High-Temperature Gas-Cooled Reactor fuel, which consisted of uranium oxycarbide fissile and ThO{sub 2} fertile TRISO particles bonded into compacts. Long before the capsule was removed from the reactor, it was obvious that the fuel was suffering early failure. After 5 of the planned 6 HFIR cycles, the peak fuel test temperature could not be controlled and the irradiation was terminated. The PIE information will be useful to fuel designers for product improvement. Irradiation-induced failure of the protective PyC layers may have led to the failure of outer PyC coatings. Coating failure fraction was determined by several means to be <1% for both fertile and fissile particles at the ends of the capsule, increasing to 6% for fissile particles and 2.5% for fertile particles at the center of the capsule. More study of SiC microstructure vs fission product release is needed. The work on capsule HRB-21 has identified a set of lessons learned that would benefit future programs.

  13. Experimental Investigation of the Supersonic Wake of a Reentry Capsule

    NARCIS (Netherlands)

    Schrijer, F.F.J.; Walpot, L.M.G.F.M.

    2010-01-01

    The wake behind an Apollo shaped capsule is investigated in the framework of the ’afterbody heating’ topic in the RTO WG043 working group. Measurements are performed by means of schlieren, shadowgraphy and stereo particle image velocimetry (SPIV) and are used for CFD validation purposes. The model

  14. 21 CFR 520.2605 - Trimeprazine tartrate and prednisolone capsules.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.2605...) Amount. Administer either capsule orally once daily to dogs as follows: Animal weight (pounds) Number of... dermatitis (allergic, parasitic, pustular, and nonspecific). It is also used in dogs as adjunctive therapy in...

  15. DEVELOPMENT OF VALUE ADDED TEA BAGS AND CAPSULES ...

    African Journals Online (AJOL)

    Ifedotun Aina

    powdered dried leaves based on Anamed International dosage recommendations. Several studies supported the use of artemisia annua tea and capsules for the treatment of malaria pointing out that flavonoids existing in the leaves and stem considerably enhance the interest of its tea preparation and powdered leave ...

  16. Biosorption of mercury by capsulated and slime layer- forming Gram ...

    African Journals Online (AJOL)

    ONOS

    2010-09-20

    Sep 20, 2010 ... The biosorption of mercury by two locally isolated Gram-ve bacilli: Klebsiella pneumoniae ssp. pneumonia (capsulated) and slime layer forming Pseudomonas aeruginosa, was characterized. Mercury adsorption was found to be influenced by the pH value of the biosorption solution, initial metal.

  17. Improved sample capsule for determination of oxygen in hemolyzed blood

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Sample capsule for determination of oxygen in hemolyzed blood consists of a measured section of polytetrafluoroethylene tubing equipped at each end with a connector and a stopcock valve. This method eliminates errors from air entrainment or from the use of mercury or syringe lubricant.

  18. Hydro-dissection and posterior capsule opacifi | Bekibele | Nigerian ...

    African Journals Online (AJOL)

    It may however be associated with early post operative complications presumably due to increased manipulation during the procedure. Its use is therefore encouraged but with generous use of viscoelastic material to reduce effect of manipulation on the eye. Keywords: hydrodissection, posterior capsule opacity, cataract ...

  19. Biosorption of mercury by capsulated and slime layerforming Gram ...

    African Journals Online (AJOL)

    The biosorption of mercury by two locally isolated Gram-ve bacilli: Klebsiella pneumoniae ssp. pneumonia (capsulated) and slime layer forming Pseudomonas aeruginosa, was characterized. Mercury adsorption was found to be influenced by the pH value of the biosorption solution, initial metal concentration, amount of the ...

  20. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  1. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  2. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  3. 77 FR 53892 - Determination That ALOXI (Palonosetron Hydrochloride) Capsules, 0.5 Milligram (Base), Were Not...

    Science.gov (United States)

    2012-09-04

    ...] Determination That ALOXI (Palonosetron Hydrochloride) Capsules, 0.5 Milligram (Base), Were Not Withdrawn From...)) Capsules, 0.5 milligram (mg) (base), were not withdrawn from sale for reasons of safety or effectiveness... HCl capsules, 0.5 mg (base), if all other legal and regulatory requirements are met. FOR FURTHER...

  4. Fabrication, characterization and evaluation of bacterial cellulose-based capsule shells for oral drug delivery

    DEFF Research Database (Denmark)

    Ullah, Hanif; Badshah, Munair; Mäkilä, Ermei

    2017-01-01

    Bacterial cellulose (BC) was investigated for the first time for the preparation of capsule shells for immediate and sustained release of drugs. The prepared capsule shells were characterized using X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The BC...... to gelatin capsules with both immediate and sustained drug release properties depending upon the compositions of the encapsulated materials....

  5. Adhesive Capsulitis in Eight Dogs: Diagnosis and Management.

    Science.gov (United States)

    Carr, Brittany J; Canapp, Sherman O; Canapp, Debra A; Gamble, Lauri-Jo; Dycus, David L

    2016-01-01

    To describe clinical and diagnostic findings as well as management of adhesive capsulitis in dogs. Adhesive capsulitis, also known as frozen shoulder, is a syndrome defined by loss of range of motion of the shoulder and may be the end-stage manifestation of several primary conditions. This is a case series report of eight dogs with chronic forelimb lameness diagnosed with adhesive capsulitis. Medical records (June 1, 2010-September 1, 2015) including, physical examination findings, radiographic findings, magnetic resonance imaging (MRI) findings, arthroscopy findings, and treatment plans were reviewed. All dogs presented with a chronic, grade III-VI/VI forelimb lameness. On orthopedic examination, all dogs had moderate to significant discomfort on shoulder extension and flexion and severe restriction of range of motion. Six of the eight dogs had evidence of bone remodeling and sclerosis in the affected shoulder on radiographs. Six of the dogs had an initial diagnostic ultrasound performed, which revealed evidence of fibrous scar tissue. Five dogs had MRI performed that revealed moderate shoulder effusion and enhancement of the synovial lining of the shoulder. Arthroscopy was performed in five of the eight patients. Three were noted to have significant contracture, adhesions, and fibrous scar tissue of the joint capsule. Severe inflammation was noted throughout the synovium of two patients. All eight patients tried conservative management consisting of oral medications and rehabilitation therapy. Five of the eight patients received extracorporeal shockwave therapy. Three patients received regenerative medicine treatment in the affected supraspinatus and shoulder. Regardless of the treatment elected, none of the dogs were reported to have significant improvement. Adhesive capsulitis is an uncommon cause of chronic forelimb lameness. Further investigation is needed to describe the etiology and pathogenesis of adhesive capsulitis in dogs to evaluate the effectiveness

  6. Adhesive Capsulitis in 8 Dogs: Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Brittany Jean Carr

    2016-07-01

    Full Text Available ABSTRACT:Objective: To describe clinical and diagnostic findings as well as management of adhesive capsulitis in dogs.Background: Adhesive capsulitis, also known as frozen shoulder, is a syndrome defined by loss of range of motion of the shoulder and may be the end-stage manifestation of several primary conditions.Evidentiary Value: This is a case report series of eight dogs with chronic forelimb lameness diagnosed with adhesive capsulitis.Methods: Medical records (June 1, 2010 to September 1, 2015 including, physical examination findings, radiographic findings, magnetic resonance imaging findings, arthroscopy findings, and treatment plans were reviewed. Results: All dogs presented with a chronic, grade III-VI/VI forelimb lameness. On orthopedic examination all dogs had moderate to significant discomfort on shoulder extension and flexion and severe restriction of range of motion. Six of the eight dogs had evidence of bone remodeling and sclerosis in the affected shoulder on radiographs. Six of had an initial diagnostic ultrasound performed, which revealed evidence of fibrous scar tissue. Five dogs had magnetic resonance imaging performed that revealed moderate shoulder effusion and enhancement of the synovial lining of the shoulder. Arthroscopy was performed in five of the eight patients. Three were noted to have significant contracture, adhesions and fibrous scar tissue of the joint capsule. Severe inflammation was noted throughout the synovium of two patients. All eight patients tried conservative management consisting of oral medications and rehabilitation therapy. Five of the eight patients received extracorporeal shockwave therapy. Three patients received regenerative medicine treatment in the affected supraspinatus and shoulder. Regardless of the treatment elected, none of the dogs were reported to have significant improvement. Conclusion: Adhesive capsulitis is an uncommon cause of chronic forelimb lameness. Further investigation is

  7. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  8. Effect of Morinda officinalis capsule on osteoporosis in ovariectomized rats.

    Science.gov (United States)

    Li, Ye; Lü, Shan-Shan; Tang, Gui-Ying; Hou, Min; Tang, Qing; Zhang, Xiao-Na; Chen, Wei-Hai; Chen, Gang; Xue, Qiang; Zhang, Cong-Cong; Zhang, Ji-Fen; Chen, Yi; Xu, Xiao-Yu

    2014-03-01

    To explore the therapeutic effects of Morinda officinalis capsules (MOP) on osteoporosis in ovariectomized rats. Six-month-old female Sprague-Dawley rats were induced for postmenopausal osteoporosis (PMOP) by bilateral ovariectomy and divided into seven groups as follows: sham-operated group, ovariectomized (OVX) control group, OVX treated with xianlinggubao (XLGB) (270 mg·kg⁻¹·d⁻¹), OVX treated with alendronate sodium (ALN) (3 mg·kg⁻¹·d⁻¹), and OVX treated with Morinda officinalis capsule (MOP) of graded doses (90, 270 and 810 mg·kg⁻¹·d⁻¹) groups. Oral treatments were administered daily on the 4(th) week after ovariectomy and lasted for 12 weeks. The bone mineral density was evaluated by dual-energy X-ray absorptiometry. The tartrate-resistant acid phosphatase (TRAP), alkaline phosphatase (AKP), and osteocalcin (OC) levels in the serum and plasma were determined by standard colorimetric and enzyme immunoassays methods. Bone biomechanical properties and morphological parameters were analyzed by three-point bending test and histomorphometry respectively. Morinda officinalis capsules at all doses were able to significantly prevent the OVX-induced loss of bone mass due to diminishing serum AKP and TRAP levels while elevating OC level in the plasma. Morinda officinalis capsules also enhanced the bone strength and prevented the deterioration of trabecular microarchitecture. Morinda officinalis capsules possess potent anti-osteoporotic activity in OVX rats which could be an effective treatment for postmenopausal osteoporosis. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  9. [Systematic review on safety of Xianling Gubao capsule].

    Science.gov (United States)

    Zhang, Yi-Li; Liao, Xing; Liu, Fu-Mei; Wang, Gui-Qian; Xie, Yan-Ming

    2017-08-01

    To systemically evaluate the safety of Xianling Gubao capsule after launching. Computer retrieval of Medline, EMbase, the Web of Science, Clinical Trials. gov, the Cochrane Library, CNKI, VIP, WanFang Data and CBM was conducted to collect information on all the research types of Xianling Gubao capsule. The literature was screened according to inclusion and exclusion criteria, and the quality of the studies was assessed according to the internationally accepted quality evaluation standards for data extraction and analysis. A total of 156 papers were included in this study, including 117 randomized control trials, 11 quasi-randomized control trials, 10 non-randomized control trials, 11 case report series, and 7 individual case reports; a total of 167 studies were analyzed. Xianling Gubao capsules were used in 7 496 patients, with an accumulative 377 cases of adverse reactions (ADR) and 4 cases of severe adverse reactions, including 1 death, 1 cerebrovascular accident, 1 case of skin allergy reaction, and 1 case of gastrointestinal discomfort; gastrointestinal system damage was most common in mild ADRs. In this study, we found that the overall safety of Xianling Gubao capsule was acceptable, but it lacked the mechanism study on the safety of the drug after marketing or the prospective long-term clinical observation study, so the further studies on the safety of drug use should be conducted. Meanwhile, the application scope of Xianling Gubao capsules was beyond the manual, in urgent needs of the relevant departments to formulate norms and provide better guidance for clinical medication. Copyright© by the Chinese Pharmaceutical Association.

  10. An ultra-low-power image compressor for capsule endoscope

    Directory of Open Access Journals (Sweden)

    Weng Ping-Kuo

    2006-02-01

    Full Text Available Abstract Background Gastrointestinal (GI endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. Methods We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. Conclusion As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.

  11. An ultra-low-power image compressor for capsule endoscope.

    Science.gov (United States)

    Lin, Meng-Chun; Dung, Lan-Rong; Weng, Ping-Kuo

    2006-02-25

    Gastrointestinal (GI) endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.

  12. Episodic memory following deep brain stimulation of the ventral anterior limb of the internal capsule and electroconvulsive therapy

    NARCIS (Netherlands)

    Bergfeld, Isidoor O; Mantione, Mariska; Hoogendoorn, Mechteld L C; Horst, Ferdinand; Notten, Peter; Schuurman, P Richard; Denys, D.

    2017-01-01

    BACKGROUND: Electroconvulsive Therapy (ECT) and Deep Brain Stimulation (DBS) are effective treatments for patients with treatment-resistant depression (TRD). However, a common side effect of ECT is autobiographical memory loss (e.g., personal experiences), whereas the impact of DBS on

  13. Episodic memory following deep brain stimulation of the ventral anterior limb of the internal capsule and electroconvulsive therapy

    NARCIS (Netherlands)

    Bergfeld, Isidoor O.; Mantione, Mariska; Hoogendoorn, Mechteld L. C.; Horst, Ferdinand; Notten, Peter; Schuurman, P. Richard; Denys, Damiaan

    2017-01-01

    Background: Electroconvulsive Therapy (ECT) and Deep Brain Stimulation (DBS) are effective treatments for patients with treatment-resistant depression (TRD). However, a common side effect of ECT is autobiographical memory loss (e.g., personal experiences), whereas the impact of DBS on

  14. Anterior chest wall examination reviewed

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the “activity” of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  15. [Anterior skull-base schwannoma].

    Science.gov (United States)

    Esquivel-Miranda, Miguel; De la O Ríos, Elier; Vargas-Valenciano, Emmanuelle; Moreno-Medina, Eva

    Schwannomas are nerve sheath tumours that originate in Schwann cells. They are usually solitary and sporadic and manifest on peripheral, spinal or cranial nerves. Intracranial schwannomas tend to manifest on the eighth cranial nerve, particularly in patients with neurofibromatosis type2. Anterior skull-base schwannomas represent less than 1% of all intracranial schwannomas. They are more frequent in young people and are typically benign. These tumours represent a diagnostic challenge due to their rarity and difficult differential diagnosis, and numerous theories have been postulated concerning their origin and development. In this article, we present the case of a 13-year-old male with a single anterior cranial-base tumour not associated with neurofibromatosis who presented with headache, papilloedema, eye pain and loss of visual acuity. Complete resection of the tumour was performed, which was histopathologically diagnosed as a schwannoma. The patient made a complete clinical recovery with abatement of all symptoms. We conducted a review of the literature and found 66 cases worldwide with this diagnosis. We describe the most relevant epidemiological and clinical characteristics of this kind of tumour and its relation with the recently discovered and similar olfactory schwannoma. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Cardio-protecteffect of qiliqiangxin capsule on left ventricular remodeling, dysfunction and apoptosis in heart failure rats after chronic myocardial infarction.

    Science.gov (United States)

    Liang, Tuo; Zhang, Yuhui; Yin, Shijie; Gan, Tianyi; An, Tao; Zhang, Rongcheng; Wang, Yunhong; Huang, Yan; Zhou, Qiong; Zhang, Jian

    2016-01-01

    Qiliqiangxin (QL) capsule is a traditional Chinese medicine which has been approved for the treatment of chronic heart failure. Evidences proved that QL capsules further reduced the NT-proBNP levels and improved left ventricular ejection fraction in CHF patients but the evidence supporting its underlying mechanism is still unclear. Myocardial infarction (MI) -Heart failure (HF) Sprague-Dawley ratsmodel and neonatal rat cardiac myocytes (NRCMs) were used. Animals were assigned into 4 groups, normal group (n=6), shame-operation group (n=6), MI rats 4 weeks after left anterior descending coronary artery ligation were randomized into vehicle group (n=8), QL group (n=8). QL significantly attenuated cardiac dysfunction and ventricle remodeling as echocardiography and hemodynamic measurements showed improvement in left ventricular ejection fraction, fractional shortening, ±dp/dt and left ventricular end diastolic and systolic diameters in QL treated group compared with the vehicle group. Improvements ininterstitial fibrosisand mitochondrial structures were also exhibited by Sirius Red staining, RT-PCR and electron microscopy. QL treatment improved apoptosis and VEGF expression in rats marginal infract area. Complementary experiments analyzed the improved apoptosis and up-regulate of VEGF in ischemia-hypoxia cultivated NRCMs is in an Akt dependent manner and can be reversed by Akt inhibitor. QL capsule can improve cardiac dysfunction and ventricular remodeling in MI-HF ratsmodel, this cardiac protective efficacy may be concerned with attenuated apoptosis and cardiac fibrosis. Up-regulated VEGF expression and Akt phosphorylation may take part in this availability.

  17. Residual mercury content and leaching of mercury and silver from used amalgam capsules.

    Science.gov (United States)

    Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R

    2002-06-01

    The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.

  18. Imaging findings of anterior hip dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Kyle [Mallinckrodt Institute of Radiology, Department of Radiology, St. Louis, MO (United States); Leslie, Michael [Yale School of Medicine, Department of Orthopedics and Rehabilitation, New Haven, CT (United States); Menn, Kirsten; Haims, Andrew [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-06-15

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  19. Imaging findings of anterior hip dislocations

    International Nuclear Information System (INIS)

    Pfeifer, Kyle; Leslie, Michael; Menn, Kirsten; Haims, Andrew

    2017-01-01

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  20. Incidental Anterior Cruciate Ligament Calcification: Case Report.

    Science.gov (United States)

    Hayashi, Hisami; Fischer, Hans

    2016-03-01

    The calcification of knee ligaments is a finding noted only in a handful of case reports. The finding of an anterior cruciate ligament calcification has been reported once in the literature. Comparable studies involving the posterior cruciate ligament, medial collateral ligament and an ossicle within the anterior cruciate ligament are likewise discussed in reports of symptomatic patients. We report a case of incidentally discovered anterior cruciate ligament calcification. We discuss the likely etiology and clinical implications of this finding.

  1. Crosslinking studies in gelatin capsules treated with formaldehyde and in capsules exposed to elevated temperature and humidity.

    Science.gov (United States)

    Ofner, C M; Zhang, Y E; Jobeck, V C; Bowman, B J

    2001-01-01

    Incomplete in vitro capsule shell dissolution and subsequent drug release problems have recently received attention. A modified USP dissolution method was used to follow capsule shell dissolution, and a 2,4,6-trinitrobenzenesulfonic acid (TNBS) assay was used to follow loss of epsilon-amino groups to study this shell dissolution problem postulated to be due to gelatin crosslinking. The dissolution problems were simulated using hard gelatin capsule (HGC) shells previously treated with formaldehyde to crosslink the gelatin. These methods were also used to study the effect of uncrosslinked HGC stored under stressed conditions (37 degrees C and 81% RH) with or without the presence of soft gelatin capsule shells (SGC). A 120 ppm formaldehyde treatment reduced gelatin shell dissolution to 8% within 45 min in water at 37 degrees C. A 200 ppm treatment reduced gelatin epsilon-amino groups to 83% of the original uncrosslinked value. The results also support earlier reports of non-amino group crosslinking by formaldehyde in gelatin. Under stressed conditions, HGC stored alone showed little change over 21 weeks. However, by 12 to 14 weeks, the HGC exposed to SGC showed a 23% decrease in shell dissolution and an 8% decrease in the number of epsilon-amino groups. These effects on the stressed HGC are ascribed to a volatile agent from SGC shells, most likely formaldehyde, that crosslinked nearby HGC shells. This report also includes a summary of the literature on agents that reduce gelatin and capsule shell dissolution and the possible mechanisms of this not-so-simple problem. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90: 79-88, 2001

  2. Cellulose nanofiber/nanocrystal reinforced capsules: a fast and facile approach toward assembly of liquid-core capsules with high mechanical stability.

    Science.gov (United States)

    Svagan, Anna J; Musyanovych, Anna; Kappl, Michael; Bernhardt, Max; Glasser, Gunnar; Wohnhaas, Christian; Berglund, Lars A; Risbo, Jens; Landfester, Katharina

    2014-05-12

    Liquid-core capsules of high mechanical stability open up for many solid state-like applications where functionality depending on liquid mobility is vital. Herein, a novel concept for fast and facile improvement of the mechanical properties of walls of liquid-core capsules is reported. By imitating nature's own way of enhancing the mechanical properties in liquid-core capsules, the parenchyma plant cells found in fruits and vegetables, a blend of short cellulose nanofibers (wood pulp hydrolysis. The capsule shell consisted of a covalently (by aromatic diisocyanate) cross-linked NFC/CNC structure at the outer capsule wall and an inner layer dominated by aromatic polyurea. The mechanical properties revealed an effective capsule elastic modulus of 4.8 GPa at 17 wt % NFC/CNC loading, about six times higher compared to a neat aromatic polyurea capsule (0.79 GPa) and 3 orders of magnitude higher than previously reported capsules from regenerated cellulose (0.0074 GPa). The outstanding mechanical properties are ascribed to the dense nanofiber structure, present in the outer part of the capsule wall, that is formed by oriented NFC/CNC of high average aspect ratio (L/d ∼ 70) and held together by both covalent (urethane bonds) and physical bonds (hydrogen bonds).

  3. Buckling and its effect on the confined flow of a model capsule suspension

    Science.gov (United States)

    Bryngelson, Spencer; Freund, Jonathan

    2015-11-01

    The rheology of confined flowing suspensions, such as blood, depend upon the dynamics of the components, which can be particularly rich when they are elastic capsules. Using boundary integral methods, we simulate a two-dimensional model channel through which flows a dense suspension of fluid-filled capsules. A parameter of principal interest is the equilibrium membrane perimeter, which ranges from round capsules to capsules with an elongated dog-bone-like equilibrium shape. It is shown that the minimum effective viscosity occurs for capsules with a biconcave equilibrium shape, similar to that of a red blood cell. The rheological behavior changes significantly over this range; transitions are linked to specific changes in the capsule dynamics. Most noteworthy is an abrupt change in behavior when capsules transition to a dog-bone-like equilibrium shape, which correlates with the onset of capsule buckling. The buckled capsules have a more varied orientation and make significant rotational (rotlet) contributions to the capsule-capsule interactions. Supported under NSF Grant No. CBET 13-36972.

  4. Comparative assessment of hepatic Glisson's capsule and bovine pericardium in heart valve bioprostheses.

    Science.gov (United States)

    Kagramanov, I I; Kokshenev, I V; Dobrova, N B; Kastava, V T; Serov, R A; Zaets, S B

    1998-05-01

    The optimal material for heart valve bioprostheses remains disputable. This investigation was initiated to compare the properties of hepatic Glisson's capsule, clinical experience of which in cardiovascular surgery is minimal, with those of bovine pericardium. Hepatic Glisson's capsule was harvested from bull calves and used to create composite pulmonary arterial monocusp grafts and bioprostheses. Comparison of the strength and elastic properties of Glisson's capsule and bovine pericardium, as well as the hydrodynamic characteristics of valves made from these materials, was performed. Late results of operations using these materials were estimated echocardiographically. Although Glisson's capsule tissue is thinner than the bovine pericardium, its elasticity modulus is greater. However, the hydrodynamic characteristics of heart valves made from either tissue are similar. Moreover, valves made from Glisson's capsule have a lower systolic pressure gradient on the prosthesis and a higher effective orifice area. Composite pulmonary arterial xenopericardial grafts with a monocusp of Glisson's capsule were used in 30 patients during tetralogy of Fallot repair. Glisson's capsule was also used for tricuspid valve reconstruction and as a bioprosthesis in six patients with Ebstein's anomaly. At 1-2 years after surgery, the Glisson's capsule tissue remained thin and flexible, with no calcification. Although the hydrodynamic properties of hepatic Glisson's capsule and the bovine pericardium are similar, the capsule tissue is thinner and has a greater elasticity modulos. Thus, Glisson's capsule may be used for bioprosthesis construction both independently and in combination with bovine pericardium.

  5. MRI of anterior knee pain.

    Science.gov (United States)

    Samim, Mohammad; Smitaman, Edward; Lawrence, David; Moukaddam, Hicham

    2014-07-01

    Anterior knee pain is the most common knee complaint. It may be due to a variety of soft tissue or osseous abnormalities. Knowledge of the radiologic appearance of the abnormalities allows more accurate diagnosis of the cause of the pain including chondral abnormalities, patellar instability and dislocation, femoral trochlear dysplasia, abnormal patellar location, bipartite patella, various tendinopathies, bursal inflammation, traction apophysitis in pediatric and adolescent patients, and miscellaneous diseases including mediopatellar plica syndrome and Hoffa's disease. Radiographs are often obtained to exclude acute osseous abnormalities, such as fractures. Magnetic resonance (MR) imaging offers superior soft tissue contrast resolution and allows for more accurate evaluation of the underlying etiology and therefore may improve treatment and possible surgical planning.

  6. Wireless capsule endoscopy of the small intestine: a review with future directions.

    Science.gov (United States)

    Neumann, Helmut; Fry, Lucía C; Nägel, Andreas; Neurath, Markus F

    2014-09-01

    Here, we review the clinical applications of small bowel capsule endoscopy. Moreover, we provide an outlook on the exceptional future developments of small bowel capsule endoscopy. We discuss clinical algorithms for diagnosis of small bowel diseases. Multiple studies have shown the potential of capsule endoscopy for identification of the bleeding source located in the small bowel and the increased diagnostic yield over radiographic studies. Capsule endoscopy could detect villous atrophy and severe complications in patients with nonresponsive celiac disease. In addition, small bowel capsule endoscopy was proven as a valid tool to diagnose polyps and tumors and Crohn's disease. Major current clinical indications of capsule endoscopy in the small bowel include evaluation of obscure gastrointestinal bleeding, diagnosis and surveillance of small bowel polyps and tumors, celiac disease and Crohn's disease. Recent developments have also passed the way for small bowel capsule endoscopy to become a therapeutic instrument.

  7. Fenestrated A1 segment of right anterior cerebral artery associated to duplicated anterior communicating artery

    OpenAIRE

    Sonda, Ildo; Basso, Luciano Silveira

    2015-01-01

    We present a case of fenestrated anterior cerebral artery associated to duplicated anterior communicating artery found duringa routine dissection of the brain in a male human body. Fenestrations of the A1 segment of the anterior cerebral artery are rare,especially if associated to a duplicated anterior communicating artery. To our knowledge, this is the second reported case in theliterature. We also present a brief review of the surgical importance of this anomaly

  8. Mild toxic anterior segment syndrome mimicking delayed onset toxic anterior segment syndrome after cataract surgery

    Directory of Open Access Journals (Sweden)

    Su-Na Lee

    2014-01-01

    Full Text Available Toxic anterior segment syndrome (TASS is an acute sterile postoperative anterior segment inflammation that may occur after anterior segment surgery. I report herein a case that developed mild TASS in one eye after bilateral uneventful cataract surgery, which was masked during early postoperative period under steroid eye drop and mimicking delayed onset TASS after switching to weaker steroid eye drop.

  9. Polyp Detection and Segmentation from Video Capsule Endoscopy: A Review

    Directory of Open Access Journals (Sweden)

    V. B. Surya Prasath

    2016-12-01

    Full Text Available Video capsule endoscopy (VCE is used widely nowadays for visualizing the gastrointestinal (GI tract. Capsule endoscopy exams are prescribed usually as an additional monitoring mechanism and can help in identifying polyps, bleeding, etc. To analyze the large scale video data produced by VCE exams, automatic image processing, computer vision, and learning algorithms are required. Recently, automatic polyp detection algorithms have been proposed with various degrees of success. Though polyp detection in colonoscopy and other traditional endoscopy procedure based images is becoming a mature field, due to its unique imaging characteristics, detecting polyps automatically in VCE is a hard problem. We review different polyp detection approaches for VCE imagery and provide systematic analysis with challenges faced by standard image processing and computer vision methods.

  10. Flexible and capsule endoscopy for screening, diagnosis and treatment.

    Science.gov (United States)

    Sliker, Levin J; Ciuti, Gastone

    2014-11-01

    Endoscopy dates back to the 1860s, but many of the most significant advancements have been made within the past decade. With the integration of robotics, the ability to precisely steer and advance traditional flexible endoscopes has been realized, reducing patient pain and improving clinician ergonomics. Additionally, wireless capsule endoscopy, a revolutionary alternative to traditional scopes, enables inspection of the digestive system with minimal discomfort for the patient or the need for sedation, mitigating some of the risks of flexible endoscopy. This review presents a research update on robotic endoscopic systems, including both flexible scope and capsule technologies, detailing actuation methods and therapeutic capabilities. A future perspective on endoscopic potential for screening, diagnostic and therapeutic gastrointestinal procedures is also presented.

  11. Compounding of slow-release niacinamide capsules: feasibility and characterization.

    Science.gov (United States)

    Radojkovic, Branko; Milić, Jela; Calija, Bojan

    2012-01-01

    The purpose of this study was to assess the feasibility of extemporaneous compounding of slow-release oral dosage form of niacinamide and to evaluate its release kinetics. The model formulation (preparation) was developed in the form of powder-filled hard gelatin capsules. Two slow-release preparations with different ratios of hypromellose have been prepared and evaluated in comparison with an immediate-release preparation. The dissolution tests were performed as per United States Pharmacopoeia requirements: Type I Apparatus, over 7 hours. Both slow-release preparations, containing 40% and 60% v/v hypromellose, respectively, have showed slow release kinetics. The dissolution profiles were significantly different, with similarity factor f2niacinamide capsules can be successfully compounded using hypromellose as a sole release rate modifier, and that the release mechanism is comparable to hydrophilic polymer matrix-based systems.

  12. Capsule physics comparison of different ablators for NIF implosion designs

    Science.gov (United States)

    Clark, Daniel; Kritcher, Andrea; Yi, Austin; Zylstra, Alex; Haan, Steven; Ralph, Joseph; Weber, Christopher

    2017-10-01

    Indirect drive implosion experiments on the Naitonal Ignition Facility (NIF) have now tested three different ablator materials: glow discharge polymer (GDP) plastic, high density carbon (HDC), and beryllium. How do these different ablator choices compare in current and future implosion experiments on NIF? What are the relative advantages and disadvantages of each? This talk compares these different ablator options in capsule-only simulations of current NIF experiments and proposed future designs. The simulations compare the impact of the capsule fill tube, support tent, and interface surface roughness for each case, as well as all perturbations in combination. According to the simulations, each ablator is impacted by the various perturbation sources differently, and each material poses unique challenges in the pursuit of ignition. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  13. Wireless capsule endoscopy of the small intestine in children.

    Science.gov (United States)

    Zevit, Noam; Shamir, Raanan

    2015-06-01

    Wireless capsule endoscopy (CE) for the diagnosis of small-bowel disease has been in clinical use for more than a decade, and is no longer an emerging technology, but rather one that has reached fruition. This noninvasive technology has been readily embraced by both physicians and patients. Used in the diagnosis of inflammatory bowel disease, for locating sources of obscure gastrointestinal bleeding, and for assessing small-bowel polyp burden in polyposis syndromes as well as for less common indications, CE has transformed the diagnostic algorithms of small-bowel investigations. Although already in widespread use, the technology incorporated into the various CE platforms continues to improve and expand. Here, we briefly review the indications, limitations, and advances in video capsule technology, with an emphasis on its use in pediatrics.

  14. A Prototype Design of a Wireless Capsule Endoscope

    Directory of Open Access Journals (Sweden)

    Y. Chan

    2006-01-01

    Full Text Available Diseases of the gastrointestinal tract, such as intestinal bleeding and ulceration, are very common. To determine the location of the disease, as well as to diagnose the problem, endoscopy is performed. A wireless capsule endoscope is a pill-sized device that is easily swallowed by the patient. It is equipped with a camera and a wireless transmitter so that as it travels through the patient's gastrointestinal tract, it takes pictures or video images of the tract and transmits the information out of the patient's body. This article discusses the possible solutions and challenges of a wireless capsule endoscope in terms of the choice of wireless frequency and circuit components. A prototype is built with commercially available components to demonstrate the concept of the device.

  15. Capsule enteroscopy and radiology of the small intestine

    International Nuclear Information System (INIS)

    Fork, Frans-Thomas; Aabakken, Lars

    2007-01-01

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  16. Totally thrombosed giant anterior communicating artery aneurysm

    Directory of Open Access Journals (Sweden)

    V R Roopesh Kumar

    2015-01-01

    Full Text Available Giant anterior communicating artery aneurysmsarerare. Apatient presented with visual dysfunction, gait ataxia and urinary incontinence. MRI showed a giant suprasellar mass.At surgery, the lesion was identified as being an aneurysm arising from the anterior communicating artery.The difficulty in preoperative diagnosis and relevant literature are reviewed.

  17. CAPSULES AS A PREVENTION OF FIBRE CLUSTERS IN CONCRETE

    OpenAIRE

    JOSEF STRYK; KAREL POSPíšIL; RADEK MATULA

    2012-01-01

    Homogenous concrete mixture without aggregate pockets and fibre clusters is a presumption for appropriate properties of concrete element or structure. There are technological measures how to achieve homogenously looking mixture from aggregate point of view, but fibres are still predisposed for clusters forming. The paper evaluates originally designed and protected within European patent treatment of fibre, based on capsules containing individual rolled fibre which can be admixed into a concre...

  18. Deep Reinforcement Learning using Capsules in Advanced Game Environments

    OpenAIRE

    Andersen, Per-Arne

    2018-01-01

    Reinforcement Learning (RL) is a research area that has blossomed tremendously in recent years and has shown remarkable potential for artificial intelligence based opponents in computer games. This success is primarily due to vast capabilities of Convolutional Neural Networks (ConvNet), enabling algorithms to extract useful information from noisy environments. Capsule Network (CapsNet) is a recent introduction to the Deep Learning algorithm group and has only barely begun to be explored. The ...

  19. Myofibroblast Upregulators are Elevated in Joint Capsules in Posttraumatic Contractures

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; Hart, David A.

    2007-01-01

    We hypothesized specific growth factors are increased in the elbow capsules of patients with post traumatic elbow contractures. A model of surgically induced joint contracture in rabbit knees was developed to study the growth factor expression in joint contractures. This study demonstrates this model mimics the human condition and analyzes how the growth factor levels decrease with time in rabbit knees with contractures. Reverse transcription polymerase chain reaction was used to measure mRNA...

  20. An Innovative Wireless Endoscopic Capsule With Spherical Shape.

    Science.gov (United States)

    Fontana, Rossella; Mulana, Francesca; Cavallotti, Carmen; Tortora, Giuseppe; Vigliar, Mario; Vatteroni, Monica; Menciassi, Arianna

    2017-02-01

    This paper aims to contribute to the advancement of the Wireless Capsule Endoscopy (WCE) field for ColoRectal Cancer (CRC) screening, by developing all electronic circuits to build an innovative wireless endoscopic capsule with a spherical shape, conceived to reduce the friction during its locomotion and thus improving patient's acceptability. The proposed capsule embeds an image sensor with optics and Light Emitting Diodes (LEDs), a control unit with a telemetry module, an actuation system, a battery with a smart recharging circuit able to recharge in 20 minutes, a smart power-on circuit and a localization module. Everything is devised to fit in a small spherical shape with a diameter of 26 mm and a weight of 12.70 g. The authors present a description of the sub-modules involved in the capsule development, together with the firmware and hardware integration. In order to reduce the bandwidth for matching the specifications of the target commercial telemetry, the firmware interfacing of a custom encoder was performed, which is able to compress the incoming images with a negligible loss of information and occupying a number of Look Up-Tables (LUTs) less than 1780. As a preliminary work, a versatile Field Programmable Gate Arrays (FPGA) based demo-board system has been developed in order to test and optimize the functionalities and the performance of the single sub-modules and wireless vision chain system. This work allows to demonstrate the feasibility of a complex biomedical system, with severe constraints by highlighting the necessity to enhance the frame rate in the future.

  1. 21 CFR 520.2100 - Selenium, vitamin E capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Selenium, vitamin E capsules. 520.2100 Section 520... to 1 milligram of selenium) and 56.2 milligrams of vitamin E (68 I.U.) (as d-alpha tocopheryl acid... of vitamin E (17 I.U.) (as d-alpha tocopheryl acid succinate.) (b) Sponsor. See No. 000061 in § 510...

  2. Analysis of Bead Sizes for MR Capsules Labeled for Sprinkle

    OpenAIRE

    Nagavelli, Laxma R.; Lionberger, Robert A.; Sayeed, Vilayat A.; Yu, Lawrence; Allgire, James; Smith, Anjanette; Wokovich, Anna; Westenberger, Benjamin J.; Buhse, Lucinda

    2010-01-01

    The bead sizes used in approved modified release capsules labeled for sprinkling on food was investigated to generate bead size guidelines for generic products labeled for sprinkling. The conclusions from a survey of FDA databases were corroborated with experimental data obtained by measuring the bead sizes of several reference-listed drugs on the market labeled for administration by sprinkling on food. The experimental data show that majority of the marketed products were found to have bead ...

  3. An ultra-low-power image compressor for capsule endoscope

    OpenAIRE

    Lin, Meng-Chun; Dung, Lan-Rong; Weng, Ping-Kuo

    2006-01-01

    Abstract Background Gastrointestinal (GI) endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the res...

  4. Capsule enteroscopy and radiology of the small intestine.

    OpenAIRE

    Fork, Thomas; Aabakken, Lars

    2007-01-01

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology....

  5. Shock Timing and Yield Sensitivity Studies for NIF Ignition Capsules

    International Nuclear Information System (INIS)

    Olson, Richard E.

    1999-01-01

    A cryogenic, β-layered NIF ignition capsule with a beryllium ablator that employs a BeO dopant (2% O) for opacity control is described. The design has an optimized yield of 12 MJ and uses a reduced drive hohlraum temperature pulse shape that peaks at ∼ 250 eV. Shock timing sensitivity calculations have been performed for this capsule design. Individual uncertainties of: (1) ∼200 ps in the timing of the foot pulse; (2) ∼5% in the x-ray flux of the foot pulse and first step; (3) ∼10% in the ablator EOS; or (4) ∼ 5 microm in the DT ice layer thickness each have a significant impact on thermonuclear yield. Combined uncertainties have greater impact than isolated, individual issues. For example, a combination of uncertainties of 200 ps in the foot + 2 eV in the foot + 5 microm in the DT thickness results in a calculation that produces only ∼ 1% of the original design yield. A second, more speculative, capsule concept utilizing a liquid DT ablator is also discussed. This design produces a 5 MJ yield in a 250 eV peak drive calculation

  6. Adhesive capsulitis and dynamic splinting: a controlled, cohort study

    Directory of Open Access Journals (Sweden)

    Willis F Buck

    2009-09-01

    Full Text Available Abstract Background Adhesive Capsulitis (AC affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in contracture reduction from pathologies including Trismus to plantar fasciitis. The purpose of this study was to examine the efficacy of dynamic splinting on patients with AC. Methods This controlled, cohort study, was conducted at four physical therapy, sports medicine clinics in Texas and California. Sixty-two patients diagnosed with Stage II Adhesive Capsulitis were grouped by intervention. The intervention categories were as follows: Group I (Control; Group II (Physical Therapy exclusively with standardized protocols; Group III; (Shoulder Dynasplint system exclusively; Group IV (Combined treatment with Shoulder Dynasplint and standardized Physical Therapy. The duration of this study was 90 days for all groups, and the main outcome measures were change in active, external rotation. Results Significant difference was found for all treatment groups (p Conclusion The difference for the combined treatment group was attributed to patients' receiving the best PT combined with structured "home therapy" that contributed an additional 90 hours of end-range stretching. This adjunct should be included in the standard of care for adhesive Capsulitis. Trial Registration Trial Number: NCT00873158

  7. Adhesive capsulitis of the hip: three case reports.

    Science.gov (United States)

    Joassin, R; Vandemeulebroucke, M; Nisolle, J-F; Hanson, P; Deltombe, T

    2008-05-01

    To describe the diagnosis and treatment of adhesive capsulitis of the hip (ACH). A literature review and consideration of three case reports. Adhesive capsulitis of the hip is a supposedly rare but probably underestimated condition which predominantly affects middle-aged women. Clinical assessment reveals a painful limitation of joint mobility. The diagnosis is confirmed by arthrography, where the crucial factor is a joint capacity below 12ml. Osteoarthritis and complex regional pain syndrome type 1 are the two main differential diagnoses. Whether the treatment is pharmacological, physical or surgical depends on the aetiology of the condition. Physiotherapy is essential for limiting residual deficits and functional impairments. Adhesive capsulitis of the hip is probably more common than suggested by the limited medical literature. The condition is frequently idiopathic but can be secondary to another joint pathology. The first-line treatment consists of sustained-release corticosteroid intra-articular injections and physical therapy. Arthroscopy and manipulation under anaesthesia may be useful in cases of ACH which are refractory to treatment.

  8. Benchmarking uranyl peroxide capsule chemistry in organic media

    International Nuclear Information System (INIS)

    Neal, Harrison A.; Nyman, May; Szymanowski, Jennifer; Fein, Jeremy B.; Burns, Peter C.

    2017-01-01

    Uranyl peroxide capsules are a recent addition to polyoxometalate (POM) chemistry. Ten years of development has ensued only in water, while transition metal POMs are commonly exploited in aqueous and organic media, controlled by counterions or ligation to render the clusters hydrophilic or hydrophobic. Here, new uranyl POM behavior is recognized in organic media, including (1) stabilization and immobilization of encapsulated hydrophilic countercations, identified by Li nuclear magnetic resonance (NMR) spectroscopy, (2) formation of new cluster species upon phase transfer, (3) extraction of uranyl clusters from different starting materials including simulated spent nuclear fuel, (4) selective phase transfer of one cluster type from a mixture, and (5) phase transfer of clusters from both acidic and alkaline media. The capsule morphology of the uranyl POMs renders accurate characterization by X-ray scattering, including the distinction of geometrically similar clusters. Compositional analysis of the aqueous phase post-extraction provided a quantitative determination of the ion exchange process that enables transfer of the clusters into the organic phase. Preferential partitioning of uranyl POMs into organic media presents new frontiers in metal ion behavior and chemical reactions in the confined space of the cluster capsules in hydrophobic media, as well as the reactivity of clusters at the organic/aqueous interface. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Benchmarking uranyl peroxide capsule chemistry in organic media

    Energy Technology Data Exchange (ETDEWEB)

    Neal, Harrison A.; Nyman, May [Department of Chemistry, Oregon State University, Corvallis, OR (United States); Szymanowski, Jennifer; Fein, Jeremy B.; Burns, Peter C. [Department of Civil and Environmental Engineering and Earth Sciences, University of Notre Dame, Notre Dame, IN (United States)

    2017-01-03

    Uranyl peroxide capsules are a recent addition to polyoxometalate (POM) chemistry. Ten years of development has ensued only in water, while transition metal POMs are commonly exploited in aqueous and organic media, controlled by counterions or ligation to render the clusters hydrophilic or hydrophobic. Here, new uranyl POM behavior is recognized in organic media, including (1) stabilization and immobilization of encapsulated hydrophilic countercations, identified by Li nuclear magnetic resonance (NMR) spectroscopy, (2) formation of new cluster species upon phase transfer, (3) extraction of uranyl clusters from different starting materials including simulated spent nuclear fuel, (4) selective phase transfer of one cluster type from a mixture, and (5) phase transfer of clusters from both acidic and alkaline media. The capsule morphology of the uranyl POMs renders accurate characterization by X-ray scattering, including the distinction of geometrically similar clusters. Compositional analysis of the aqueous phase post-extraction provided a quantitative determination of the ion exchange process that enables transfer of the clusters into the organic phase. Preferential partitioning of uranyl POMs into organic media presents new frontiers in metal ion behavior and chemical reactions in the confined space of the cluster capsules in hydrophobic media, as well as the reactivity of clusters at the organic/aqueous interface. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Dumbbell formation for elastic capsules in nonlinear extensional Stokes flows

    Science.gov (United States)

    Dimitrakopoulos, P.

    2017-06-01

    Cross-slot and four-roll-mill microdevices are commonly used for particle manipulation and characterization owing to the stagnation-point flow at the device center. Because of the solid boundaries, these devices may generate extensional Stokes flows where the velocity is a nonlinear function of position associated with a decreased pressure at the particle edges and an increased pressure at the particle middle. Our computational investigation shows that in this class of Stokes flows, an elastic capsule made of a strain-hardening membrane develops two distinct steady-state conformations at strong flows, i.e., an elongated weak dumbbell shape with rounded edges at low flow nonlinearity and a laterally extended dumbbell shape at high flow nonlinearity. These effects are more pronounced for the less strain-hardening capsules which develop a flat extended middle where the two sides of the membrane approach each other. The strong stability properties of the strain-hardening capsules (owing to the development of strong membrane tensions) contrast significantly with the behavior of droplets in these nonlinear flows which are unable to achieve highly deformed steady-state dumbbell shapes owing to their constant surface tension.

  11. Liberty Bell 7 Space Capsule Exhibit previews at Visitor Complex

    Science.gov (United States)

    2000-01-01

    Media gather at the KSC Visitor Complex for the kickoff of the Discovery Channel's Liberty Bell 7 Space Capsule Exhibit, which will open to the public on Saturday, June 17. At the podium is Mike Quattrone, executive vice president and general manager, Discovery Channel. Standing to the left of the podium is Rick Abramson, president and chief operating officer of Delaware North Parks Services of Spaceport, Inc., and far left, Jim Jennings, deputy director of Kennedy Space Center. Liberty Bell 7 launched U.S. Air Force Captain Virgil '''Gus''' Grissom July 21, 1961 on a mission that lasted 15 minutes and 37 seconds before sinking to the floor of the Atlantic Ocean, three miles deep. It lay undetected for nearly four decades before a Discovery Channel expedition located it and recovered it. The space capsule is now restored and preserved, and part of an interactive exhibit touring science centers and museums in 12 cities throughout the United States until 2003. The exhibit includes hands-on elements such as a capsule simulator, a centrifuge, and ROV pilot.

  12. Lateral migration of a capsule in a parabolic flow.

    Science.gov (United States)

    Nix, S; Imai, Y; Ishikawa, T

    2016-07-26

    Red blood cells migrate to the center of the blood vessel in a process called axial migration, while other blood cells, such as white blood cells and platelets, are disproportionately found near the blood vessel wall. However, much is still unknown concerning the lateral migration of cells in the blood; the specific effect of hydrodynamic factors such as a wall or a shear gradient is still unclear. In this study, we investigate the lateral migration of a capsule using the boundary integral method, in order to compute exactly an infinite computational domain for an unbounded parabolic flow and a semi-infinite computational domain for a near-wall parabolic flow in the limit of Stokes flow. We show that the capsule lift velocity in an unbounded parabolic flow is linear with respect to the shear gradient, while the lift velocity in a near-wall parabolic flow is dependent on the distance to the wall. Then, using these relations, we give an estimation of the relative effect of the shear gradient as a function of channel width and distance between the capsule and the wall. This estimation can be used to determine cases in which the effect of the shear gradient or wall can be neglected; for example, the formation of the cell-free layer in blood vessels is determined to be unaffected by the magnitude of the shear gradient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  14. Controllable light capsules employing modified Bessel-Gauss beams.

    Science.gov (United States)

    Gong, Lei; Liu, Weiwei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-07-08

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new route for generating and controlling bottle beams and will widen the potentials for micromanipulation of absorbing particles, aerosols or even individual atoms.

  15. In-Situ Preparation of Radioactive Tracers in NIF Capsules

    Science.gov (United States)

    Stoyer, Mark

    2011-04-01

    Inertial Confinement Fusion (ICF) experiments at the National Ignition Facility (NIF) will probe fundamental high energy density physics of plasmas. Radiochemical diagnostics will provide information on ablator and fuel rho-R, yield, asymmetry, and mix by collecting both gaseous and solid debris samples following an implosion. Many experiments utilize ratios of produced activities, but full utilization of the technique requires knowledge of sample collection efficiencies. Gaseous samples are expected to be collected with high efficiency, but solid sample collection is typically limited by location of the collecting apparatus. Activation of ICF capsules has been utilized at other laser facilities [1-2] to produce a radioactive tracer in the ablator of the capsule that can be used to measure the solid collection efficiency. This talk will describe preliminary experiments activating CH(Ge) NIF capsules and Au hohlraums in the High Flux Isotope Reactor (HFIR) at ORNL in order to produce Ge, As, and Au isotopes for determination of collection efficiency, spatial distribution of the debris, efficacy of various collectors, and if there are preferred locations for debris collection. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. S.M. Lane and M.B. Nelson, Rev. Sci. Inst. 61 (1990) 3298.

  16. Outcome of using the histological pseudocapsule as a surgical capsule in Cushing disease.

    Science.gov (United States)

    Jagannathan, Jay; Smith, Rene; DeVroom, Hetty L; Vortmeyer, Alexander O; Stratakis, Constantine A; Nieman, Lynnette K; Oldfield, Edward H

    2009-09-01

    Many patients with Cushing disease still have active or recurrent disease after pituitary surgery. The histological pseudocapsule of a pituitary adenoma is a layer of compressed normal anterior lobe that surrounds the adenoma and can be used during surgery to identify and guide removal of the tumor. In this study the authors examined the results of using the pseudocapsule as a surgical capsule in the resection of adenomas in patients with Cushing disease. The authors reviewed a prospective database of data obtained in patients with Cushing disease who underwent surgery. The analysis included all cases in which a lesion was identified during surgery and in which the lesion was believed to be confined to the pituitary gland in patients with Cushing disease between January 1990 and March 2007. Since the objective was to determine the success of using the pseudocapsule as a surgical capsule, patients with invasive tumors and patients in whom no lesion was identified during surgery-challenging cases for surgical success-were excluded from analysis. In 261 patients an encapsulated adenoma was identified at surgery. Tumor was visible on MR imaging in 135 patients (52%); in 126 patients (48%) MR imaging detected no tumor. The range of tumor size overlapped considerably in the groups with positive and negative MR imaging results, indicating that in addition to size other features of the adenoma influence the results of MR imaging. In 252 patients hypercortisolism resolved after the first operation, whereas in 9 patients (3 with positive MR imaging and 6 with negative MR imaging) early reoperation was required. Hypercortisolism resolved in all 261 patients (256 with hypocortisolism and 5 with eucortisolism) before hospital discharge. Forty-six patients (18%) had postoperative electrolyte abnormalities (30 with hyponatremia and 16 with diabetes insipidus), but only 2 patients required treatment at discharge. The mean clinical follow-up duration was 84 months (range 12

  17. Glenohumeral posterior mobilization versus conventional physiotherapy for primary adhesive capsulitis: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Héctor Joaquín Gutiérrez Espinoza

    2015-09-01

    Full Text Available OBJETIVO Demostrar la efectividad a corto plazo de la técnica de movilización posterior glenohumeral, en la mejoría del rango de rotación externa en pacientes con capsulitis adhesiva primaria de hombro. MÉTODOS El presente estudio clínico aleatorizado, fue realizado en el Hospital Clínico San Borja Arriarán, donde 57 participantes en un rango de edad entre 50 y 58 años, fueron asignados de forma aleatoria a uno de dos grupos de tatamiento. A ambos grupos se les dio un tratamiento de 10 sesiones. El grupo experimental (n=29 recibió la técnica de movilización posterior glenohumeral luego de un entrenamiento con cicloergómetro. El grupo control (n=28 participó de un programa de tratamiento kinésico convencional. La medida de resultado primaria fue el rango de movimiento pasivo de rotación externa, las mediciones secundarias fueron el rango de flexión anterior y abducción, la percepción del dolor se midió con la escala visual analógica y la funcionalidad usando el puntaje de Constant-Murley. RESULTADOS El estudio fue diseñado con potencia estadística para detectar una diferencia de cuatro grados en el rango de rotación externa entre los grupos al finalizar el tratamiento. El grupo experimental mostró una mejoría significativa con un promedio de la diferencia de 46,3 grados y desviación estándar 8,7 grados en comparación con el grupo control con 18,1 grados y desviación estándar 7,2 grados (p<0,0001. También hubo una disminución en la percepción del dolor (p=0,0002 y mejoró la funcionalidad (p<0,0001 en el grupo tratado con movilización posterior glenohumeral. CONCLUSIONES La movilización posterior glenohumeral aplicada luego de un entrenamiento con cicloergómetro es una técnica efectiva a corto plazo en el manejo terapéutico de la capsulitis adhesiva primaria. Este tratamiento disminuye el dolor y mejora la función comparado con un tratamiento kinésico convencional. El grado de incremento en la rotaci

  18. Bowman Capsulitis Predicts Poor Kidney Allograft Outcome in T Cell-Mediated Rejection.

    Science.gov (United States)

    Gallan, Alexander J; Chon, W James; Josephson, Michelle A; Cunningham, Patrick N; Henriksen, Kammi J; Chang, Anthony

    2018-02-28

    Acute T cell-mediated rejection (TCMR) is an important cause of renal allograft loss. The Banff classification for tubulointerstitial (type I) rejection is based on the extent of both interstitial inflammation and tubulitis. Lymphocytes may also be present between parietal epithelial cells and Bowman capsules in this setting, which we have termed "capsulitis." We conducted this study to determine the clinical significance of capsulitis. We identified 42 patients from the pathology archives at the University of Chicago with isolated Banff type I TCMR from 2010-2015. Patient demographic data, Banff classification, and graft outcome measurements were compared between capsulitis and non-capsulitis groups using Mann-Whitney U test. Capsulitis was present in 26 (62%), and was more frequently seen in Banff IB than IA TCMR (88% vs 44%, P=.01). Patients with capsulitis had a higher serum creatinine at biopsy (4.6 vs 2.9mg/dL, P=.04) and were more likely to progress to dialysis (42% vs 13%, P=.06) with fewer recovering their baseline serum creatinine (12% vs 38%, P=.08). Patients with both Banff IA TCMR and capsulitis have clinical outcomes similar or possibly worse than Banff IB TCMR compared to those with Banff IA and an absence of capsulitis. Capsulitis is an important pathologic parameter in the evaluation of kidney transplant biopsies with potential diagnostic, prognostic, and therapeutic implications in the setting of TCMR. Copyright © 2018. Published by Elsevier Inc.

  19. Current applications and potential future role of wireless capsule technology in Crohn's disease.

    Science.gov (United States)

    Hall, Barry; Holleran, Grainne; McNamara, Deirdre

    2014-11-01

    The development of capsule technology has modified our approach to the diagnosis of gastrointestinal disease. The relatively rapid uptake of capsule endoscopy as an important clinical tool can be largely ascribed to a number of key factors, including the fact that it is a relatively easy examination to perform in an outpatient setting. It has been established as an integral part of the investigation pathway for obscure gastrointestinal bleeding and suspected small bowel Crohn's disease (CD). CURRENT USE OF CAPSULE ENDOSCOPY: Small bowel CD can be a challenging entity to diagnose. Capsule endoscopy has been shown to be both useful and safe in patients with both suspected and established small bowel CD. In suspected disease, capsule endoscopy has both a high diagnostic yield and negative predictive value. Capsule findings lead to changes in management in up to 73% of patients with established CD. However, while the technology appears capable of detecting subtle mucosal changes not readily apparent on alternate imaging modalities, the question of what actually constitutes small bowel CD as described by capsule is an issue that remains unresolved to date. Thus, capsule endoscopy is best utilised in tandem with advanced imaging and endoscopic techniques such as balloon- assisted enteroscopy. The development of a capsule capable of viewing the colon coupled with improvements in image quality and battery life are likely to lead to the increasing uptake of this technology. In the future, 'interactive' capsules with the ability to view the entire gastrointestinal tract may be a reality.

  20. The roles of Tenascin C and Fibronectin 1 in adhesive capsulitis: a pilot gene expression study.

    Science.gov (United States)

    Cohen, Carina; Leal, Mariana Ferreira; Belangero, Paulo Santoro; Figueiredo, Eduardo Antônio; Smith, Marília Cardoso; Andreoli, Carlos Vicente; de Castro Pochini, Alberto; Cohen, Moises; Ejnisman, Benno; Faloppa, Flávio

    2016-07-01

    We evaluated mRNA expression levels of genes that encode TGF-β1; the TGF-β1 receptor; the collagen-modifying enzymes LOX, PLOD1, and PLOD2; and the extracellular matrix proteins COMP, FN1, TNC and TNXB in synovial/capsule specimens from patients with idiopathic adhesive capsulitis. Possible associations between the measured mRNA levels and clinical parameters were also investigated. We obtained glenohumeral joint synovium/capsule specimens from 9 patients with idiopathic adhesive capsulitis who had not shown improvement in symptoms after 5 months of physiotherapy. Adhesive capsulitis was confirmed in all patients by magnetic resonance imaging. We also obtained specimens from 8 control patients who had underwent surgery for acute acromioclavicular joint dislocation and who had radiological indication of glenohumeral capsule alteration based on arthroscopic evaluation. mRNA expression in the synovium/capsule specimens was analyzed by quantitative reverse transcription PCR. The B2M and HPRT1 genes were used as references to normalize target gene expression in the shoulder tissue samples. The synovium/capsule samples from the patients with adhesive capsulitis had significantly higher TNC and FN1 expression than those from the controls. Additionally, symptom duration directly correlated with expression of TGFβ1 receptor I. Elevated levels of TNC and FN1 expression may be a marker of capsule injury. Upregulation of TGFβ1 receptor I seems to be dependent on symptom duration; therefore, TGFβ signaling may be involved in adhesive capsulitis. As such, TNC, FN1 and TGFβ1 receptor I may also play roles in adhesive capsulitis by contributing to capsule inflammation and fibrosis.

  1. The roles of Tenascin C and Fibronectin 1 in adhesive capsulitis: a pilot gene expression study

    Directory of Open Access Journals (Sweden)

    Carina Cohen

    Full Text Available OBJECTIVES: We evaluated mRNA expression levels of genes that encode TGF-β1; the TGF-β1 receptor; the collagen-modifying enzymes LOX, PLOD1, and PLOD2; and the extracellular matrix proteins COMP, FN1, TNC and TNXB in synovial/capsule specimens from patients with idiopathic adhesive capsulitis. Possible associations between the measured mRNA levels and clinical parameters were also investigated. METHODS: We obtained glenohumeral joint synovium/capsule specimens from 9 patients with idiopathic adhesive capsulitis who had not shown improvement in symptoms after 5 months of physiotherapy. Adhesive capsulitis was confirmed in all patients by magnetic resonance imaging. We also obtained specimens from 8 control patients who had underwent surgery for acute acromioclavicular joint dislocation and who had radiological indication of glenohumeral capsule alteration based on arthroscopic evaluation. mRNA expression in the synovium/capsule specimens was analyzed by quantitative reverse transcription PCR. The B2M and HPRT1 genes were used as references to normalize target gene expression in the shoulder tissue samples. RESULTS: The synovium/capsule samples from the patients with adhesive capsulitis had significantly higher TNC and FN1 expression than those from the controls. Additionally, symptom duration directly correlated with expression of TGFβ1 receptor I. CONCLUSION: Elevated levels of TNC and FN1 expression may be a marker of capsule injury. Upregulation of TGFβ1 receptor I seems to be dependent on symptom duration; therefore, TGFβ signaling may be involved in adhesive capsulitis. As such, TNC, FN1 and TGFβ1 receptor I may also play roles in adhesive capsulitis by contributing to capsule inflammation and fibrosis.

  2. Anterior Cruciate Ligament Reconstruction Rehabilitation

    Science.gov (United States)

    Wright, Rick W.; Haas, Amanda K.; Anderson, Joy; Calabrese, Gary; Cavanaugh, John; Hewett, Timothy E.; Lorring, Dawn; McKenzie, Christopher; Preston, Emily; Williams, Glenn; Amendola, Annunziato

    2015-01-01

    Context: Anterior cruciate ligament (ACL) reconstruction rehabilitation has evolved over the past 20 years. This evolution has been driven by a variety of level 1 and level 2 studies. Evidence Acquisition: The MOON Group is a collection of orthopaedic surgeons who have developed a prospective longitudinal cohort of the ACL reconstruction patients. To standardize the management of these patients, we developed, in conjunction with our physical therapy committee, an evidence-based rehabilitation guideline. Study Design: Clinical review. Level of Evidence: Level 2. Results: This review was based on 2 systematic reviews of level 1 and level 2 studies. Recently, the guideline was updated by a new review. Continuous passive motion did not improve ultimate motion. Early weightbearing decreases patellofemoral pain. Postoperative rehabilitative bracing did not improve swelling, pain range of motion, or safety. Open chain quadriceps activity can begin at 6 weeks. Conclusion: High-level evidence exists to determine appropriate ACL rehabilitation guidelines. Utilizing this protocol follows the best available evidence. PMID:26131301

  3. Superior vena caval syndrome and ipsilateral pleural effusion: A rare presentation of anterior mediastinal thymoma

    Directory of Open Access Journals (Sweden)

    Anirban Das

    2014-01-01

    Full Text Available Incidence of thymic malignancies is very low. Thymoma, a tumor of thymus gland, is of epithelial origin and is most common anterior mediastinal tumor. In most cases, thymomas are localized and locally advanced thymomas may rarely present with superior vena caval obstruction (SVCO and malignant pleural deposits. Microscopically, capsular invasion is noted in case of locally advanced thymomas, which behave like a malignant neoplasm. Complete surgical removal of the tumor along with intact capsule is the treatment modality of choice in case of localized tumors. Neoadjuvant radiotherapy (RT and chemotherapy followed by surgical resection of residual tumor is useful in case of locally advanced tumors. RT is especially useful in case of SVCO to relieve the distressing respiratory symptoms. Here, we report a rare case of locally advanced thymoma, complicated by SVCO and ipsilateral pleural effusion in a 53-year-old male patient.

  4. Investigating the effects of membrane deformability on artificial capsule adhesion to the functionalized surface.

    Science.gov (United States)

    Balsara, Hiren D; Banton, Rohan J; Eggleton, Charles D

    2016-10-01

    Understanding, manipulating and controlling cellular adhesion processes can be critical in developing biomedical technologies. Adhesive mechanisms can be used to the target, pattern and separate cells such as leukocytes from whole blood for biomedical applications. The deformability response of the cell directly affects the rolling and adhesion behavior under viscous linear shear flow conditions. To that end, the primary objective of the present study was to investigate numerically the influence of capsule membrane's nonlinear material behavior (i.e. elastic-plastic to strain hardening) on the rolling and adhesion behavior of representative artificial capsules. Specifically, spherical capsules with radius of [Formula: see text] were represented using an elastic membrane governed by a Mooney-Rivlin strain energy functions. The surfaces of the capsules were coated with P-selectin glycoprotein-ligand-1 to initiate binding interaction with P-selectin-coated planar surface with density of [Formula: see text] under linear shear flow varying from 100 to [Formula: see text]. The numerical model is based on the Immersed Boundary Method for rolling of deformable capsule in shear flow coupled with Monte Carlo simulation for receptor/ligand interaction modeled using Bell model. The results reveal that the mechanical properties of the capsule play an important role in the rolling behavior and the binding kinetics between the capsule contact surface and the substrate. The rolling behavior of the strain hardening capsules is relatively smoother and slower compared to the elastic-plastic capsules. The strain hardening capsules exhibits higher contact area at any given shear rate compared to elastic-plastic capsules. The increase in contact area leads to decrease in rolling velocity. The capsule contact surface is not in complete contact with the substrate because of thin lubrication film that is trapped between the capsule and substrate. This creates a concave shape on the bottom

  5. Microscope-Integrated Intraoperative Ultrahigh-Speed Swept-Source Optical Coherence Tomography for Widefield Retinal and Anterior Segment Imaging.

    Science.gov (United States)

    Lu, Chen D; Waheed, Nadia K; Witkin, Andre; Baumal, Caroline R; Liu, Jonathan J; Potsaid, Benjamin; Joseph, Anthony; Jayaraman, Vijaysekhar; Cable, Alex; Chan, Kinpui; Duker, Jay S; Fujimoto, James G

    2018-02-01

    To demonstrate the feasibility of retinal and anterior segment intraoperative widefield imaging using an ultrahigh-speed, swept-source optical coherence tomography (SS-OCT) surgical microscope attachment. A prototype post-objective SS-OCT using a 1,050-nm wavelength, 400 kHz A-scan rate, vertical cavity surface-emitting laser (VCSEL) light source was integrated to a commercial ophthalmic surgical microscope after the objective. Each widefield OCT data set was acquired in 3 seconds (1,000 × 1,000 A-scans, 12 × 12 mm 2 for retina and 10 × 10 mm 2 for anterior segment). Intraoperative SS-OCT was performed in 20 eyes of 20 patients. In six of seven membrane peels and five of seven rhegmatogenous retinal detachment repair surgeries, widefield retinal imaging enabled evaluation pre- and postoperatively. In all seven cataract cases, anterior imaging evaluated the integrity of the posterior lens capsule. Ultrahigh-speed SS-OCT enables widefield intraoperative viewing in the posterior and anterior eye. Widefield imaging visualizes ocular structures and pathology without requiring OCT realignment. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:94-102.]. Copyright 2018, SLACK Incorporated.

  6. Conservative treatment of excessive anterior pelvic tilt

    DEFF Research Database (Denmark)

    Brekke, Anders Falk

    , DK-5000 Odense C, Denmark ABSTRACT (1795 anslag) Background: Excessive anterior pelvic tilt has been linked to pain and dysfunction of the hip and pelvic region. Conservative treatment (e.g. manual therapy and physical training) is suggested in correcting the tilt and eventually related symptoms....... However, the effectiveness in reducing excessive anterior pelvic tilt in adults is unknown. Purpose: To systematically review studies investigating the effectiveness of conservative treatment in reducing anterior pelvic tilt in adults and evaluate the quality of evidence. Materials and methods: MEDLINE...

  7. CT findings in malignant anterior mediastinal tumors

    International Nuclear Information System (INIS)

    Narimatsu, Akiko; Higuchi, Mutsuo; Shigeta, Akiko

    1992-01-01

    Materials were 26 malignant anterior mediastinal tumors: 7 thymic carcinomas, 6 invasive thymomas, 7 malignant lymphomas (ML) and 6 malignant germ cell tumors (GCT). Egg shell calcification in the tumor was indicative of the invasive thymoma. Presence of conglomerated mass in the anterior mediastinum strongly suggested the diagnosis of ML. Although differentiation between thymic carcinoma and ML was difficult, punctate calcification and pleural implants were frequently found in the former. GCT showed no significant findings on CT. However, another clinical information was helpful to make correct diagnosis. CT guided biopsy is necessary to diagnose the malignant anterior mediastinal tumors. (author)

  8. CT findings in malignant anterior mediastinal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Narimatsu, Akiko; Higuchi, Mutsuo; Shigeta, Akiko (Tokyo Women' s Medical Coll. (Japan))

    1992-07-01

    Materials were 26 malignant anterior mediastinal tumors: 7 thymic carcinomas, 6 invasive thymomas, 7 malignant lymphomas (ML) and 6 malignant germ cell tumors (GCT). Egg shell calcification in the tumor was indicative of the invasive thymoma. Presence of conglomerated mass in the anterior mediastinum strongly suggested the diagnosis of ML. Although differentiation between thymic carcinoma and ML was difficult, punctate calcification and pleural implants were frequently found in the former. GCT showed no significant findings on CT. However, another clinical information was helpful to make correct diagnosis. CT guided biopsy is necessary to diagnose the malignant anterior mediastinal tumors. (author).

  9. Adhesive capsulitis of the shoulder: review of pathophysiology and current clinical treatments.

    Science.gov (United States)

    Le, Hai V; Lee, Stella J; Nazarian, Ara; Rodriguez, Edward K

    2017-04-01

    Adhesive shoulder capsulitis, or arthrofibrosis, describes a pathological process in which the body forms excessive scar tissue or adhesions across the glenohumeral joint, leading to pain, stiffness and dysfunction. It is a debilitating condition that can occur spontaneously (primary or idiopathic adhesive capsulitis) or following shoulder surgery or trauma (secondary adhesive capsulitis). Here, we review the pathophysiology of adhesive shoulder capsulitis, highlighting its clinical presentation, natural history, risk factors, pathoanatomy and pathogenesis. Both current non-operative and operative treatments for adhesive capsulitis are described, and evidence-based studies are presented in support for or against each corresponding treatment. Finally, the review also provides an update on the gene expression profile of adhesive capsulitis and how this new understanding can help facilitate development of novel pharmacological therapies.

  10. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    Science.gov (United States)

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  11. DETERMINATION OF THE AGR-1 CAPSULE TO FPMS SPECTROMETER TRANSPORT VOLUMES FROM LEADOUT FLOW TEST DATA

    Energy Technology Data Exchange (ETDEWEB)

    J. K. Hartwell; J. B. Walter; D. M. Scates; M. W. Drigert

    2007-05-01

    The AGR-1 experiment is a fueled multiple-capsule irradiation experiment being conducted in the Advanced Test Reactor (ATR) in support of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. A flow experiment conducted during the AGR-1 irradiation provided data that included the effect of flow rate changes on the decay of a short-lived radionuclide (23Ne). This data has been analyzed to determine the capsule-specific downstream transport volume through which the capsule effluents must pass before arrival at the fission product monitoring system spectrometers. These resultant transport volumes when coupled with capsule outlet flow rates determine the transport times from capsule-to-detector. In this work an analysis protocol is developed and applied in order to determine capsule-specific transport volumes to precisions of better than +/- 7%.

  12. Structure of capsule around acanthocephalan Corynosoma strumosum from uncommon paratenic hosts-lizards of two species.

    Science.gov (United States)

    Skorobrechova, Ekaterina M; Nikishin, Vladimir P; Lisitsyna, Olga I

    2012-01-01

    Micromorphology and ultrastructure of capsule forming around acanthocephalan Corynosoma strumosum in uncommon paratenic hosts-lizards Lacerta agilis and Lacerta viridis-have been studied. Experimental infestation of the lizards by acanthocephalans obtained from naturally infested sea fishes showed that only small amount of parasites occurred in the intestine of the host was able to migrate into body cavity and to be encapsulated. Micromorphology of capsules of different ages from different species of lizards and micromorphology and ultrastructure of capsules at the age of 1.5 and 10 days appeared to be similar. In the capsule's structure cells of inflammatory rank were prevailing: mononuclear and multinuclear macrophages, eosinophils, and basophils. Fibroblasts were not numerous and were located only in the outer part of a capsule; exocellular collagen fibers were absent. Inflammatory character of capsule confirms the idea that lizards are unsuitable paratenic hosts for corynosomes.

  13. Experimental Investigation of the Spiral Structure of a Magnetic Capsule Endoscope

    Directory of Open Access Journals (Sweden)

    Wanan Yang

    2016-06-01

    Full Text Available Fitting a wireless capsule endoscope (WCE with a navigation feature can maximize its functional benefits. The rotation of a spiral-type capsule can be converted to translational motion. The study investigated how the spiral structure and rotational speed affected the capsule's translation speed. A hand-held instrument, including two permanent magnets, a stepper motor, a controller and a power supplier, were designed to generate rotational magnetic fields. The surfaces of custom-built permanent magnet rings magnetized radially were mounted in spiral lines with different lead angles and diameters, acting as mock-up capsules. The experimental results demonstrate that the rotational speed of the magnetic field and the spiral have significant effects on the translational speed of a capsule. The spiral line with a larger lead angle and the rotating magnetic field with a higher speed can change the capsule's rotation into a translational motion more efficiently in the intestine.

  14. Changes of anterior and posterior corneal curvature and anterior chamber depth after SMILE

    Directory of Open Access Journals (Sweden)

    Li Li

    2017-12-01

    Full Text Available AIM: To observe the changes of anterior and posterior corneal curvature and anterior chamber depth after small incision lenticule extraction(SMILEfor low and high myopic astigmatism. METHODS: Sixty-three cases(88 eyesundergone SMILE in our hospital were included. The patients were divided into two groups based on astigmatism degree: the Group A: -2.00D to -4.00D astigmatism, the Group B: -0.25D to -1.00D astigmatism. Patients were examined at 1wk, 1 and 3mo after operations. Visual acuity, intraocular pressure, refraction, corneal curvature and anterior chamber depth were recorded. The change of anterior and posterior corneal curvature and anterior chamber depth was compared. Spearman correlation analysis and independent t test were used for statistical analysis. RESULTS: Surgery was done well in all patients without complications. No statistically significant difference was found between the two groups in posterior corneal curvature and anterior chamber depth preoperatively, postoperatively 7d,1 and 3mo(P>0.05. One week postoperatively, the anterior corneal curvature was statistically significant from that of preoperative in both groups(PP>0.05. CONCLUSION: No significant change of anterior and posterior corneal curvature and anterior chamber depth was found after SMILE for correcting low and high myopic astigmatism. One week after SMILE the anterior corneal curvature become stable.

  15. Revision Anterior Cruciate Ligament Reconstruction

    Science.gov (United States)

    Wilde, Jeffrey; Bedi, Asheesh; Altchek, David W.

    2014-01-01

    Context: Reconstruction of the anterior cruciate ligament (ACL) is one of the most common surgical procedures, with more than 200,000 ACL tears occurring annually. Although primary ACL reconstruction is a successful operation, success rates still range from 75% to 97%. Consequently, several thousand revision ACL reconstructions are performed annually and are unfortunately associated with inferior clinical outcomes when compared with primary reconstructions. Evidence Acquisition: Data were obtained from peer-reviewed literature through a search of the PubMed database (1988-2013) as well as from textbook chapters and surgical technique papers. Study Design: Clinical review. Level of Evidence: Level 4. Results: The clinical outcomes after revision ACL reconstruction are largely based on level IV case series. Much of the existing literature is heterogenous with regard to patient populations, primary and revision surgical techniques, concomitant ligamentous injuries, and additional procedures performed at the time of the revision, which limits generalizability. Nevertheless, there is a general consensus that the outcomes for revision ACL reconstruction are inferior to primary reconstruction. Conclusion: Excellent results can be achieved with regard to graft stability, return to play, and functional knee instability but are generally inferior to primary ACL reconstruction. A staged approach with autograft reconstruction is recommended in any circumstance in which a single-stage approach results in suboptimal graft selection, tunnel position, graft fixation, or biological milieu for tendon-bone healing. Strength-of-Recommendation Taxonomy (SORT): Good results may still be achieved with regard to graft stability, return to play, and functional knee instability, but results are generally inferior to primary ACL reconstruction: Level B. PMID:25364483

  16. Anatomic anterior cruciate ligament reconstruction: reducing anterior tibial subluxation.

    Science.gov (United States)

    Muller, Bart; Duerr, Eric R H; van Dijk, C Niek; Fu, Freddie H

    2016-09-01

    To measure and compare the amount of anterior tibial subluxation (ATS) after anatomic ACL reconstruction for both acute and chronic ACL-deficient patients. Fifty-two patients were clinically and radiographically evaluated after primary, unilateral, anatomic ACL reconstruction. Post-operative true lateral radiographs were obtained of both knees with the patient in supine position and knees in full passive extension with heels on a standardized bolster. ATS was measured on the radiographs by two independent and blinded observers. ATS was calculated as the side-to-side difference in tibial position relative to the femur. An independent t test was used to compare ATS between those undergoing anatomic reconstruction for an acute versus chronic ACL injury. Chronic ACL deficiency was defined as more than 12 weeks from injury to surgery. Patients averaged 26.4 ± 11.5 years (mean ± SD) of age, 43.6 % were female, and 48.1 % suffered an injury of the left knee. There were 30 and 22 patients in the acute and chronic groups, respectively. The median duration from injury to reconstruction for the acute group was 5 versus 31 weeks for the chronic group. After anatomic ACL reconstruction, the mean ATS was 1.0 ± 2.1 mm. There was no statistical difference in ATS between the acute and chronic groups (1.2 ± 2.0 vs. 0.6 ± 2.3 mm, n.s.). Assessment of inter-tester reliability for radiographic evaluation of ATS revealed an excellent intraclass correlation coefficient of 0.894. Anatomic ACL reconstruction reduces ATS with a mean difference of 1.0 mm from the healthy contralateral limb. This study did not find a statistical difference in ATS between patients after anatomic ACL reconstruction in the acute or chronic phase. These observations suggest that anatomic ACL reconstruction, performed in either the acute or the chronic phase, approaches the normal AP relationship of the tibiofemoral joint. IV.

  17. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    Science.gov (United States)

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  18. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    Science.gov (United States)

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  20. Photostability of Mecobalamin in Tablet and Capsule at the Dispensing Level

    OpenAIRE

    Saeki, Takao; Katagiri, Yoshihiro; Hirano, Hidenari; Naora, Kohji

    1984-01-01

    Photostability of mecobalamin in solid dosage forms was investigated at dispensing level. Commercial products of one tablet and five capsules were used in packaged and bared conditions. The sample products were exposed to light for 20 days at 1500 lux. Assay was by high-performance liquid chromatography. The amount of mecobalamin in tablet and capsules decreased with lapse of photoirradiation time. Significant difference in the rate of photodegradation was observed between the capsule dosage ...

  1. The roles of Tenascin C and Fibronectin 1 in adhesive capsulitis: a pilot gene expression study

    OpenAIRE

    Cohen, Carina; Leal, Mariana Ferreira; Belangero, Paulo Santoro; Figueiredo, Eduardo Antônio; Smith, Marília Cardoso; Andreoli, Carlos Vicente; de Castro Pochini, Alberto; Cohen, Moises; Ejnisman, Benno; Faloppa, Flávio

    2016-01-01

    OBJECTIVES: We evaluated mRNA expression levels of genes that encode TGF-β1; the TGF-β1 receptor; the collagen-modifying enzymes LOX, PLOD1, and PLOD2; and the extracellular matrix proteins COMP, FN1, TNC and TNXB in synovial/capsule specimens from patients with idiopathic adhesive capsulitis. Possible associations between the measured mRNA levels and clinical parameters were also investigated. METHODS: We obtained glenohumeral joint synovium/capsule specimens from 9 patients with ...

  2. Patient-reported measures of quality of life and functional capacity in adhesive capsulitis

    OpenAIRE

    Fernandes, Marcos Rassi

    2017-01-01

    Summary Objective: To evaluate patient-reported measures of quality of life and functional capacity in adhesive capsulitis before and after suprascapular nerve block treatment; to analyze the influence of clinical and sociodemographic variables on both the outcome and correlation between the respective instruments. Method: A prospective clinical study was performed with adhesive capsulitis patients. Inclusion criteria were clinical diagnosis of adhesive capsulitis and a shoulder imaging tes...

  3. Role of wireless capsule endoscopy in reclassifying inflammatory bowel disease in children

    OpenAIRE

    Jodie Ouahed; Mohammad Shagrani; Ana Sant’Anna

    2013-01-01

    Objective: To evaluate the role of wireless capsule endoscopy in identifying small bowel lesions in pediatric patients with newly diagnosed colonic inflammatory bowel disease (IBD) type unclassified (IBDU), and to assess whether capsule endoscopy findings result in altered patient management. Methods: Ten pediatric patients recently diagnosed with IBDU through standard investigations were recruited from the pediatric gastroenterology clinic at McMaster Children's Hospital to undergo capsul...

  4. Distal anterior inferior cerebellar artery syndrome after acoustic neuroma surgery.

    Science.gov (United States)

    Hegarty, Joseph L; Jackler, Robert K; Rigby, Peter L; Pitts, Lawrence H; Cheung, Steven W

    2002-07-01

    To define a clinicopathologic syndrome associated with persistent cerebellar dysfunction after acoustic neuroma (AN) excision. Case series derived from radiographic and clinical chart review. Tertiary referral center. In 12 patients with AN, persistent cerebellar dysfunction developed after AN removal. Each case demonstrated abnormality in the ipsilateral cerebellar peduncle on postoperative magnetic resonance imaging. Cerebellar function and ambulatory status over the first postoperative year. On magnetic resonance imaging scans, the extent of cerebellar peduncle infarcts was variable. It ranged from focal brain injury (2 cm) spanning the full thickness of the peduncle. Peduncular infarcts were associated with large tumor size (average 3.8 cm, range 2.0-5.5 cm diameter). The long-term functional outcomes (>1 yr) varied. Dysmetria was unchanged or improved in over half of the patients (6 of 11 patients). Gait recovered to normal or to preoperative levels in 5 patients. In the 6 patients with persistent impaired mobility, 2 had mild gait disturbance, 3 required regular use of a cane, and 1 has been dependent on a walker. One patient had sustained mild motor weakness. Three of 11 patients remained dependent on others for activities of daily living. Peduncle injury most likely stems from interruption of distal branches of the anterior inferior cerebellar artery (AICA). These small vessels are intimately related to the capsule of the tumor and may supply both the neoplasm and the brain parenchyma. It has long been recognized that interruption of the proximal segment of the AICA results in severe injury to the pons, with devastating neurologic sequelae. A limited AICA syndrome caused by loss of its distal ramifications seems a more plausible explanation for peduncular infarction than either venous insufficiency or direct surgical trauma.

  5. Factors affecting anterior knee pain following anatomic double-bundle anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Niki, Yasuo; Hakozaki, Akihiro; Iwamoto, Wataru; Kanagawa, Hiroya; Matsumoto, Hideo; Toyama, Yoshiaki; Suda, Yasunori

    2012-08-01

    The purpose of this study was to evaluate the prevalence of anterior knee pain in anatomic double-bundle anterior cruciate ligament (ACL) reconstruction and to identify critical factors affecting postoperative anterior knee pain development. Subjects comprised 171 patients (171 knees) who underwent anatomic double-bundle ACL reconstruction with a follow-up period of ≥2 years. The procedure used bone-patellar tendon-bone plus gracilis tendon (BTB-G) in 56 knees, semitendinosus tendon (ST) in 71 knees, and ST-G in 44 knees. Clinical results and prevalence and severity of anterior knee pain were assessed at 3 months and 2 years postoperatively. Clinical variables influencing anterior knee pain development at each postoperative period were subjected to univariate analysis, followed by logistic regression analysis to identify risk factors for anterior knee pain. Overall prevalences of anterior knee pain at 3 months and 2 years postoperatively were 42.0 and 11.1%, respectively. Use of BTB-G graft represented the highest prevalence of anterior knee pain between the 3 different grafts (P = 0.001); however, this statistical significance disappeared at 2 years postoperatively. Prevalence of postoperative extension deficit was significantly higher in anterior knee pain-positive cohort than in anterior knee pain-negative cohort at 3 months postoperatively. Level of quadriceps strength was significantly lower, and Lysholm score was significantly worse in anterior knee pain-positive cohort than in anterior knee pain-negative cohort at 2 years postoperatively. According to logistic regression analysis, knee extension deficit was a predisposing factor for the development of anterior knee pain at 3 months postoperatively (odds ratio, 2.76; P = 0.004); however, there was no significant predisposing factor for anterior knee pain at 2 years postoperatively. Knee extension deficit was an important predisposing factor for postoperative anterior knee pain in the early

  6. Phenotypic Heterogeneity in Expression of the K1 Polysaccharide Capsule of Uropathogenic Escherichia coli and Downregulation of the Capsule Genes during Growth in Urine.

    Science.gov (United States)

    King, Jane E; Aal Owaif, Hasan A; Jia, Jia; Roberts, Ian S

    2015-07-01

    Uropathogenic Escherichia coli (UPEC) is the major causative agent of uncomplicated urinary tract infections (UTI). The K1 capsule on the surface of UPEC strains is a key virulence factor, and its expression may be important in the onset and progression of UTI. In order to understand capsule expression in more detail, we analyzed its expression in the UPEC strain UTI89 during growth in rich medium (LB medium) and urine and during infection of a bladder epithelial cell line. Comparison of capsule gene transcription using a chromosomal gfp reporter fusion showed a significant reduction in transcription during growth in urine compared to that during growth in LB medium. When examined at the single-cell level, following growth in both media, capsule gene expression appears to be heterogeneous, with two distinct green fluorescent protein (GFP)-expressing populations. Using anti-K1 antibody, we showed that this heterogeneity in gene expression results in two populations of encapsulated and unencapsulated cells. We demonstrated that the capsule hinders attachment to and invasion of epithelial cells and that the unencapsulated cells within the population preferentially adhere to and invade bladder epithelial cells. We found that once internalized, UTI89 starts to produce capsule to aid in its intracellular survival and spread. We propose that this observed phenotypic diversity in capsule expression is a fitness strategy used by the bacterium to deal with the constantly changing environment of the urinary tract. Copyright © 2015 King et al.

  7. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  8. Learning to Diagnose Cirrhosis with Liver Capsule Guided Ultrasound Image Classification

    Directory of Open Access Journals (Sweden)

    Xiang Liu

    2017-01-01

    Full Text Available This paper proposes a computer-aided cirrhosis diagnosis system to diagnose cirrhosis based on ultrasound images. We first propose a method to extract a liver capsule on an ultrasound image, then, based on the extracted liver capsule, we fine-tune a deep convolutional neural network (CNN model to extract features from the image patches cropped around the liver capsules. Finally, a trained support vector machine (SVM classifier is applied to classify the sample into normal or abnormal cases. Experimental results show that the proposed method can effectively extract the liver capsules and accurately classify the ultrasound images.

  9. Current evidence on physical therapy in patients with adhesive capsulitis: what are we missing?

    Science.gov (United States)

    Struyf, Filip; Meeus, Mira

    2014-05-01

    Adhesive capsulitis is, in most cases, a self-limiting condition of poorly understood etiology that results in shoulder pain and large mobility deficits. The socio-economic burden will increase as with continuous aging of our population. In addition, both prevalence and incidence figures of adhesive capsulitis are increasing. No literature overview solely focuses on the physiotherapeutic options in patients with adhesive capsulitis and their scientific evidence. Moreover, although some physiotherapeutic interventions show evidence regarding reducing pain or increasing mobility, there is little evidence to suggest that the disease prognosis is affected and this raises the need for new, innovative research in the area of adhesive capsulitis and its treatment. By presenting its current evidence, we hope to retrieve several gaps in the present management of adhesive capsulitis by physiotherapists and provide us with new insights for improving the physiotherapists' policy in treating adhesive capsulitis patients, e.g., continuously increasing nociceptive impulse activity, as in early stages of adhesive capsulitis, could lead to peripheral and subsequently long-lasting central sensitization, as well as to an increased activity of the sympathetic nervous system. But up to now the involvement of central sensitization in adhesive capsulitis has not been studied yet and remains speculative. Finally, when selecting a physical treatment method for adhesive capsulitis, it is extremely important to consider the patient's symptoms, stage of the condition, and recognition of different patterns of motion loss. Guidelines for clinical assessment will be presented in this scoping review.

  10. The prevalence of a diabetic condition and adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Tighe, Connie B; Oakley, Ward S

    2008-06-01

    Adhesive capsulitis is characterized by a progressive and painful loss of shoulder motion of unknown etiology. Previous studies have found the prevalence of adhesive capsulitis to be slightly greater than 2% in the general population. However, the relationship between adhesive capsulitis and diabetes mellitus (DM) is well documented, with the incidence of adhesive capsulitis being two to four times higher in diabetics than in the general population. It affects about 20% of people with diabetes and has been described as the most disabling of the common musculoskeletal manifestations of diabetes. Consented patients presenting with adhesive capsulitis reporting no history of DM had blood testing for diabetes and prediabetes. An anonymous database was analyzed for a diabetic condition. The prevalence of diabetes in patients with adhesive capsulitis was 38.6% (34 of 88). The prevalence of prediabetes was 32.95% (29 of 88). The total prevalence of a diabetic condition in patients with adhesive capsulitis was 71.5% (63 of 88). Previous literature fails to reveal the incidence of newly diagnosed diabetes, 2 of 88 (2%), and prediabetes, 25 of 88 (28.4%) in patients presenting with adhesive capsulitis. Early diagnosis and effective management of DM reduces the risk of microvascular complications. DM is believed to play a role in the development of musculoskeletal complications. Awareness of these findings alerts the practitioner to the risk of diabetes and prediabetes in patients presenting with adhesive capsulitis of the shoulder.

  11. PhD Dissertation Proposal - Introduction to Dark Mix Concept: Gamma Measurements of Capsule Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Meaney, Kevin Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-06

    Presentation slides: Intro to Inertial Confinement Fusion; Types of Mixture in ICF capsules; Previous mixture experiments; Dark Mix Concept; Measuring Dark Mix with Gamma Cherenkov Detector; Dissertation Outline.

  12. Inductive-Based Wireless Power Recharging System for an Innovative Endoscopic Capsule

    Directory of Open Access Journals (Sweden)

    Giuseppe Tortora

    2015-09-01

    Full Text Available Wireless capsule endoscopic devices are adopted for painless diagnosis of cancer and other diseases affecting the gastrointestinal tract as an alternative to traditional endoscopy. Although much work has been done to improve capsule performance in terms of active navigation, a major drawback is the limited available energy on board the capsule, usually provided by a battery. Another key shortcoming of active capsules is their limitation in terms of active functionalities and related costs. An inductive-based wireless recharging system for the development of an innovative capsule for colonoscopy is proposed in this paper; the aim is to provide fast off-line battery recovery for improving capsule lifecycle and thus reducing the cost of a single endoscopic procedure. The wireless recharging system has been properly designed to fit the dimensions of a capsule for colonoscopy but it can be applied to any biomedical devices to increase the number of times it can be used after proper sterilization. The current system is able to provide about 1 W power and is able to recharge the battery capsule in 20 min which is a reasonable time considering capsule operation time (10–15 min.

  13. [Exploring the clinical characters of Shugan Jieyu capsule through text mining].

    Science.gov (United States)

    Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai

    2017-09-01

    The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.

  14. Effectiveness of corticosteroid injections in adhesive capsulitis of shoulder

    Science.gov (United States)

    Wang, Wei; Shi, Mingmin; Zhou, Chenhe; Shi, Zhongli; Cai, Xunzi; Lin, Tiao; Yan, Shigui

    2017-01-01

    Abstract Background: Primary adhesive capsulitis is mainly characterized by spontaneous chronic shoulder pain and the gradual loss of shoulder motion. The main treatment for adhesive capsulitis is a trial of conservative therapies, including analgesia, exercise, physiotherapy, oral nonsteroidal anti-inflammation drugs, and intra-articular corticosteroid injections. Previously, it was reported that intra-articular corticosteroid lead to fast pain relief and improvement of range of motion (ROM). The objective of this study was to determine whether corticosteroid injections would lead to better pain relief and greater improvement in ROM. Methods: We searched PubMed, Medline, and the Cochrane library. We included 5 articles of the 1166 articles identified. Totally injection group included 115 patients and placebo group included 110 patients. We calculated the weighted mean differences to evaluate the pain relief as the primary outcome. We determined the ROM as the secondary outcome. Study quality was evaluated using the 12-item scale. We also used the criteria of the Grading of Recommendations Assessment, Development and Evaluation to evaluate the quality of evidence. Results: In total, 5 studies were included, 4 of which were randomized clinical trials, with a sample size of 225 patients with adhesive capsulitis of the shoulders. The overall pooled data demonstrated that, compared with placebo as control treatment, intra-articular corticosteroid injections were more effective in reducing the pain score at 0 to 8 weeks, but there was no difference between the injection group and the control group at 9 to 24 weeks. Improvement of ROM in the injection group was greater than that of the control group both at 0 to 8 and 9 to 24 weeks. Conclusions: Intra-articular corticosteroid injections were more effective in pain relief in the short term, but this pain relief did not sustain in the long term. Intra-articular corticosteroid injection resulted in greater improvement in

  15. Numerical simulation of weakly ionized hypersonic flow over reentry capsules

    Science.gov (United States)

    Scalabrin, Leonardo C.

    The mathematical and numerical formulation employed in the development of a new multi-dimensional Computational Fluid Dynamics (CFD) code for the simulation of weakly ionized hypersonic flows in thermo-chemical non-equilibrium over reentry configurations is presented. The flow is modeled using the Navier-Stokes equations modified to include finite-rate chemistry and relaxation rates to compute the energy transfer between different energy modes. The set of equations is solved numerically by discretizing the flowfield using unstructured grids made of any mixture of quadrilaterals and triangles in two-dimensions or hexahedra, tetrahedra, prisms and pyramids in three-dimensions. The partial differential equations are integrated on such grids using the finite volume approach. The fluxes across grid faces are calculated using a modified form of the Steger-Warming Flux Vector Splitting scheme that has low numerical dissipation inside boundary layers. The higher order extension of inviscid fluxes in structured grids is generalized in this work to be used in unstructured grids. Steady state solutions are obtained by integrating the solution over time implicitly. The resulting sparse linear system is solved by using a point implicit or by a line implicit method in which a tridiagonal matrix is assembled by using lines of cells that are formed starting at the wall. An algorithm that assembles these lines using completely general unstructured grids is developed. The code is parallelized to allow simulation of computationally demanding problems. The numerical code is successfully employed in the simulation of several hypersonic entry flows over space capsules as part of its validation process. Important quantities for the aerothermodynamics design of capsules such as aerodynamic coefficients and heat transfer rates are compared to available experimental and flight test data and other numerical results yielding very good agreement. A sensitivity analysis of predicted radiative

  16. Quantitative and Computed Tomography Anatomic Analysis of Glenoid Fixation for Superior Capsule Reconstruction: A Cadaveric Study.

    Science.gov (United States)

    Schon, Jason M; Katthagen, J Christoph; Dupre, Cameron N; Mitchell, Justin J; Turnbull, Travis Lee; Adams, Christopher R; Denard, Patrick J; Millett, Peter J

    2017-06-01

    To investigate glenoid fixation for superior capsule reconstruction (SCR) and evaluate anchor positions, intraosseous trajectories, and proximity to the suprascapular nerve (SSN) and glenoid fossa. The secondary purpose was to provide technical pearls and pitfalls for anchor insertion on the superior glenoid during SCR. Three beath pins were arthroscopically inserted into 12 (n = 12) nonpaired human cadaveric shoulders through Neviaser, anterior, and posterior portals to simulate anchor placement on the superior glenoid during SCR. Computed tomography scans were performed to evaluate anchor positioning and insertion trajectories. Specimens were then dissected to delineate the anatomic relations of the beath pins to the SSN and glenoid fossa. The superior glenoid anchor position was a mean 15.0 ± 4.0 mm to the SSN and 6.5 ± 1.7 mm to the glenoid fossa. The posterior glenoid anchor position was a mean 11.8 ± 2.1 mm to the SSN and 2.9 ± 2.9 mm to the glenoid fossa. On average, the superior pin was placed at 12:30 ± 0:30 (left-sided glenoid clock face) and inserted at 19° ± 9° with respect to the sagittal plane of the glenoid, the anterior pin was placed at 11:00 ± 0:30 and inserted 40° ± 17° off the glenoid, and the posterior pin was placed at 3:00 ± 1:00 and inserted at 52° ± 12° off the glenoid. The results of the present cadaveric study showed that glenoid fixation was safe with respect to the SSN and delineated technical guidelines and trajectories for inserting 3 anchors into the glenoid. This study shows that 3 anchors can be inserted into the glenoid without a risk of SSN damage and delineates technical guidelines for anchor insertion. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Upper anterior zone restoration with composites

    OpenAIRE

    Lamas Lara, César; CD, Docente del Área de Operatoria Dental y Endodoncia de la Facultad de Odontología de la UNMSM.; Angulo de la Vega, Giselle; CD, Alumna de la Especialidad de Rehabilitación Oral de la Facultad de Odontología de la UNMSM.

    2014-01-01

    The anterior sector problems are very common in our professional practice and became vital importance to make a suitable rehabilitation in these cases; we can not do a good rehabilitation if we do not know the basic characteristics, both aesthetic and functional. Today the composites are a valid alternative for the restoration of the anterior sector, since they offer to us a conservative and aesthetic possibility, but independently of the material to use we have to based on certain rules or p...

  18. Conservative treatment of excessive anterior pelvic tilt

    DEFF Research Database (Denmark)

    Brekke, Anders Falk

    quality by two reviewers using Cochrane Collaboration’s tool for assessing risk of bias in RCT’s and the ROBINS-I tool (Risk Of Bias In Non-randomized Studies - of interventions). Data was synthesized qualitatively. The GRADE approach was used to determine the overall quality of the evidence. PROSPERO...... treatment may reduce anterior pelvis tilt and reduce symptoms in relation to faulty posture. Keywords: pelvis, anterior tilt, anteversion, posture...

  19. Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Packiyalakshmi, Sathiya; Jacob, Soosan; Agarwal, Athiya

    2013-08-01

    To evaluate the complications and visual outcomes of glued intrascleral-fixated foldable intraocular lens (IOL) in eyes with deficient capsules. Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India. Case series. Data were evaluated from the records of patients with a primary glued foldable IOL for intraoperative capsular loss or subluxated lens or secondary glued foldable IOL for aphakia. Exclusion criteria included preoperative glaucoma, aniridia, macular scar, traumatic subluxation, combined surgeries, incomplete operative medical records, and postoperative follow-up less than 6 months. The intraoperative and postoperative complication rates, reoperation rate, and visual outcomes were analyzed. The study comprised 208 eyes (185 patients). The mean follow-up was 16.7 months ± 10.2 (SD). The intraoperative complications were hyphema (0.4%), haptic breakage (0.4%), and deformed haptics (0.9%). Early complications occurred in 29 eyes (13.9%) and included corneal edema (5.7%), epithelial defect (1.9%), and grade 2 anterior chamber reaction (2.4%). Late complications occurred in 39 eyes (18.7%) and included optic capture (4.3%), IOL decentration (3.3%), haptic extrusion (1.9%), subconjunctival haptic (1.4%), macular edema (1.9%), and pigment dispersion (1.9%). Reoperation was required in 16 eyes (7.7%). Haptic position was altered in eyes with IOL decentration. Corrected distance visual acuity (CDVA) improved or remained unchanged in 84.6% of eyes. The postoperative CDVA was 20/40 or better and 20/60 or better in 38.9% and 48.5% of eyes, respectively. The foldable glued-IOL procedure showed satisfactory visual outcomes without serious complications. Intraocular lens decentration was due to haptic-related problems. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Wireless capsule endoscopy as a tool in diagnosing autoimmune enteropathy

    DEFF Research Database (Denmark)

    Gram-Kampmann, Eva-Marie; Lillevang, Søren T; Detlefsen, Sönke

    2015-01-01

    Autoimmune enteropathy (AE) is an immune mediated illness of the intestinal mucosa. The cause is unknown, and the diagnosis is based on typical characteristics displayed. There is no gold standard for treatment. We present two adult cases of AE and demonstrate the challenges in establishing...... the diagnosis. The extensive diagnostic work up excluded other more common causes of protracted diarrhoea. Wireless capsule endoscopy (WCE) displayed universal small intestinal mucosal damage with shortened villi that led to the suspicion of AE in both patients. The diagnosis was confirmed with microscopy....... Use of WCE as a diagnostic tool was invaluable in establishing the diagnosis of AE....

  1. Clinical evaluation of arthroscopic treatment of shoulder adhesive capsulitis

    OpenAIRE

    Miyazaki, Alberto Naoki; Santos, Pedro Doneux; Silva, Luciana Andrade; Sella, Guilherme do Val; Carrenho, Leonardo; Checchia, Sergio Luiz

    2017-01-01

    ABSTRACT OBJECTIVE: To evaluate the results of arthroscopic releases performed in patients with adhesive capsulitis refractory to conservative treatment. METHODS: This was a retrospective study, conducted between 1996 and 2012, which included 56 shoulders (52 patients) that underwent surgery; 38 were female, and 28 had the dominant side affected. The mean age was 51 (29-73) years. The mean follow-up was 65 (12-168) months and the mean preoperative time was 8.9 (2-24) months. According to ...

  2. A reflux capsule steam generator for sodium cooled reactors

    International Nuclear Information System (INIS)

    Lantz, E.

    Pressurized water reactor plants at numerous sites have sustained significant leakage through their steam generators. The consequent shutdowns for repairs and replacements have damaged their economics. This experience suggests that if steam generators for liquid metal fast breeder reactors (LMFBR's) continue to be built as presently designed some of them will have similar problems. Because of their larger capital investment, the consequent damage to the economics of LMFBR's could be more serious. Reflux capsules provide a way to separate sodium from water and to reduce thermal stresses in steam generators for sodium cooled reactors. Their use would also eliminate the need for a primary heat exchanger and a secondary sodium loop pump. (author)

  3. Small-bowel neoplasms in patients undergoing video capsule endoscopy

    DEFF Research Database (Denmark)

    Rondonotti, E; Pennazio, M; Toth, E

    2008-01-01

    BACKGROUND AND STUDY AIM: Small-bowel tumors account for 1% - 3% of all gastrointestinal neoplasms. Recent studies with video capsule endoscopy (VCE) suggest that the frequency of these tumors may be substantially higher than previously reported. The aim of the study was to evaluate the frequency...... of the neoplasm seen in 29 centers of 10 European Countries. RESULTS: Of 5129 patients undergoing VCE, 124 (2.4%) had small-bowel tumors (112 primary, 12 metastatic). Among these patients, indications for VCE were: obscure gastrointestinal bleeding (108 patients), abdominal pain (9), search for primary neoplasm...

  4. CAPSULES AS A PREVENTION OF FIBRE CLUSTERS IN CONCRETE

    Directory of Open Access Journals (Sweden)

    JOSEF STRYK

    2012-12-01

    Full Text Available Homogenous concrete mixture without aggregate pockets and fibre clusters is a presumption for appropriate properties of concrete element or structure. There are technological measures how to achieve homogenously looking mixture from aggregate point of view, but fibres are still predisposed for clusters forming. The paper evaluates originally designed and protected within European patent treatment of fibre, based on capsules containing individual rolled fibre which can be admixed into a concrete mixture and set up homogenously in its whole volume within the mixing process.

  5. Endoscopic laser anterior commissurotomy for anterior glottic web: one-stage procedure.

    Science.gov (United States)

    Su, Chih-Ying; Alswiahb, Jamil N; Hwang, Chung-Feng; Hsu, Cheng-Ming; Wu, Pei-Yin; Huang, Hsun-Hsien

    2010-05-01

    The conventional method for preventing web formation after anterior glottic web surgery is keel insertion. However, this presents risks of airway compromise and granulation tissue formation, which could necessitate tracheotomy in addition to a secondary procedure for keel removal. We introduce a novel, 1-stage endoscopic laser anterior commissurotomy for preventing anterior glottic web re-formation. Twenty patients with glottic webs involving the anterior commissure were studied. The lesions were removed by transoral carbon dioxide laser microsurgery. In all patients, the anterior glottic web was vaporized along with the inner perichondrium of the thyroid cartilage over the anterior commissure area, creating a raw vertical break "alley" between the anterior vocal folds that measured between 0.3 and 0.5 cm in width and between 0.8 and 2 cm in length. The preoperative and postoperative vocal folds and voice quality were evaluated by videostrobolaryngoscopy and voice recordings. All 20 patients had anterior glottic webs ranging from 11% to 64% of the length from the anterior commissure to the vocal process. None of the patients developed restenosis at the anterior commissure of a severity similar to that of the initial lesion during follow-up (mean, 13 months; range, 3 to 44 months).All patients except 1 reported satisfaction with their voice improvement. Outcome analysis revealed that partial re-formation of the web was noted in 4 patients. One-stage, endoscopic laser anterior commissurotomy was effective and relatively safe for removing glottic webs, for preventing anterior glottic web re-formation, and for improving vocal fold performance among our patients.

  6. Ultrasound biomicroscopy of the anterior segment.

    Science.gov (United States)

    Liebmann, J M; Ritch, R

    1996-08-01

    New imaging technologies are revolutionizing the understanding and treatment of a wide variety of ocular disorders. Confocal scanning laser ophthalmoscopy, ultrasound biomicroscopy, confocal scanning laser polarimetry, color doppler imaging of blood flow, and optical coherence tomography are providing important information regarding disease pathophysiology, diagnosis, progression, and treatment. High frequency (50 MHz), high resolution ultrasound biomicroscopy of the anterior segment was obtained in a wide variety of disorders of the anterior segment. Tissue resolution is approximately 50 microns and the penetration depth is 5 mm. Ultrasound biomicroscopy is capable of imaging the comea, iris, anterior chamber, anterior chamber angle, posterior chamber, and ciliary body with great detail. The structures surrounding the posterior chamber, previously hidden from clinical observation, can be imaged and their normal anatomic relationships assessed. The various forms of angle closure glaucoma, such as pupillary block and plateau iris configuration, can be differentiated. The concave iris found in pigment dispersion and its response to treatment can be assessed. Visualization of anterior segment anatomy in eyes with opaque media is possible. Ultrasound biomicroscopy assists in the management of eyes with disorders of the anterior segment. Future applications of this technology will yield important information regarding accommodation, normal ocular physiology and disease pathophysiology.

  7. In vitro analysis of anterior and posterior fixation in an experimental unstable burst fracture model.

    Science.gov (United States)

    Kallemeier, Patricia M; Beaubien, Brian P; Buttermann, Glenn R; Polga, David J; Wood, Kirkham B

    2008-05-01

    A biomechanical comparison of fixation constructs in an experimental fracture model. To determine the relative postoperative stability of anterior graft and plating with that of posterior or combined fixation constructs in an unstable thoracolumbar burst fracture model. Several treatment modalities have been proposed for unstable thoracolumbar burst fractures, but the optimal technique is unclear. Previous cadaveric biomechanical studies in unstable burst fracture models have not considered the commonly used posterior (interpedicular) and anterior (plate) constructs. Nine human spine segments (T11-L3) were potted in epoxy and scanned using dual energy x-ray absorptiometry and computed tomography. Intact specimens had baseline flexibility testing. Unstable L1 burst fractures as verified by computed tomography were created using an impulse load and posterior surgical osteoligamentous destabilization (ie, transection of the lamina, interspinous ligaments, facet capsules, and ligamentum flavum). Specimens were instrumented posteriorly with pedicle screws and rods and tested to 6 Nm in flexion-extension, lateral bending, and torsion. Corpectomy and strut grafting were then performed, and testing was repeated in varying order with posterior fixation, anterior plating and circumferential fixation. Range of motion (ROM) and neutral zone was calculated for each test and fixation groups were compared using analysis of variance. All specimens had AO B1.2 (unstable burst) fractures. Mean ROM for posterior-only constructs was significantly less than that of the intact in lateral bending, flexion, and extension (Pbending (Ptorsion (all at Ptorsion. Increased ROM was correlated with greater fracture comminution for posterior-only fixation (P<0.05), and was weakly correlated with lower dual energy x-ray absorptiometry score (R=0.3) for anterior-only fixation. Circumferential instrumentation provided the most rigid fixation, followed by posterior fixation with anterior strut

  8. The Superior Frontal Transsulcal Approach to the Anterior Ventricular System: Exploring the Sulcal and Subcortical Anatomy Using Anatomic Dissections and Diffusion Tensor Imaging Tractography.

    Science.gov (United States)

    Koutsarnakis, Christos; Liakos, Faidon; Kalyvas, Aristotelis V; Skandalakis, Georgios P; Komaitis, Spyros; Christidi, Fotini; Karavasilis, Efstratios; Liouta, Evangelia; Stranjalis, George

    2017-10-01

    To explore the superior frontal sulcus (SFS) morphology, trajectory of the applied surgical corridor, and white matter bundles that are traversed during the superior frontal transsulcal transventricular approach. Twenty normal, adult, formalin-fixed cerebral hemispheres and 2 cadaveric heads were included in the study. The topography, morphology, and dimensions of the SFS were recorded in all specimens. Fourteen hemispheres were investigated through the fiber dissection technique whereas the remaining 6 were explored using coronal cuts. The cadaveric heads were used to perform the superior frontal transsulcal transventricular approach. In addition, 2 healthy volunteers underwent diffusion tensor imaging and tractography reconstruction studies. The SFS was interrupted in 40% of the specimens studied and was always parallel to the interhemispheric fissure. The proximal 5 cm of the SFS (starting from the SFS precentral sulcus meeting point) were found to overlie the anterior ventricular system in all hemispheres. Five discrete white matter layers were identified en route to the anterior ventricular system (i.e., the arcuate fibers, the frontal aslant tract, the external capsule, internal capsule, and the callosal radiations). Diffusion tensor imaging studies confirmed the fiber tract architecture. When feasible, the superior frontal transsulcal transventricular approach offers a safe and effective corridor to the anterior part of the lateral ventricle because it minimizes brain retraction and transgression and offers a wide and straightforward working corridor. Meticulous preoperative planning coupled with a sound microneurosurgical technique are prerequisites to perform the approach successfully. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Prevalence and Classification of Injuries of Anterolateral Complex in Acute Anterior Cruciate Ligament Tears.

    Science.gov (United States)

    Ferretti, Andrea; Monaco, Edoardo; Fabbri, Mattia; Maestri, Barbara; De Carli, Angelo

    2017-01-01

    To report on the prevalence of injuries of the lateral compartment occurring in cases of apparently isolated acute anterior cruciate ligament (ACL) tears and to present a classification system of anterolateral complex injuries based on the data obtained. Sixty patients operated on for an acute apparently isolated ACL tear, revealed by clinical examination and confirmed by magnetic resonance imaging, were prospectively selected. The lateral compartment was exposed and injuries were detected. Based on the data obtained, lesions of the anterolateral complex were classified as follows: Type I: multilevel rupture with individual layers torn at different levels with macroscopic hemorrhage involving the area of the anterolateral ligament (ALL) and extended to the anterolateral capsule. Type II: multilevel rupture with individual layers torn at different levels with macroscopic hemorrhage extended from the area of the ALL and capsule to the posterolateral capsule. Type III: complete transverse tear involving the area of the ALL near its insertion to the lateral tibial plateau, distal to the lateral meniscus. Type IV: bony avulsion (Segond fracture). The pivot-shift test was repeated intraoperatively after repair of lateral tears before the ACL reconstruction. Although magnetic resonance imaging was able to detect only bony injuries (Segond fracture), macroscopic tears of the lateral capsule were clearly identified at surgery in 54 of 60 patients and classified as follows: Type I: 19/60 Type II: 16/60 Type III: 13/60 Type IV: 6/60 In all cases, repair resulted in a marked reduction or apparent disappearance of the pivot-shift phenomenon. Statistical analysis showed a positive correlation between lesions of the lateral compartment, regardless of the type described, and a pivot shift graded 2 or 3. Because injuries of secondary restraints often occur in cases of acute ACL tears, recognition and repair of such lesions could be considered to help ACL reconstruction to better

  10. Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.

    Science.gov (United States)

    KuKanich, Butch; Warner, Matt; Hahn, Kevin

    2017-02-01

    OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.

  11. Magnesium ion acts as a signal for capsule induction in Cryptococcus neoformans

    Directory of Open Access Journals (Sweden)

    Sudarshan Singh Rathore

    2016-03-01

    Full Text Available Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF. To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C.neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C.neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C.neoformans and 37°C for Clinical C.neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C.neoformans. While investigating the individual components of artificial CSF, we found that Mg2+ ions influence the capsule growth in both environmental and clinical strains of C.neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60 and CAP64 in various capsule inducing media and in different concentrations of Mg 2+ and Ca2+. Our results on gene expression suggest that, Mg2+ does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg2+ ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C.neoformans.

  12. Development of the instrumented capsule for nuclear fuel irradiation test at HANARO

    International Nuclear Information System (INIS)

    Sohn, Jae Min; Oh, Jong Myung; Park, Sung Jae; Shin, Yoon Taeg; Kim, Bong Goo; Kang, Young Hwan; Kim, Hark Rho; Kim, Young Jin

    2006-01-01

    The instrumented capsule for the nuclear fuel irradiation test (hereinafter referred to as 'instrumented fuel capsule'), which is crucial for the verification of a nuclear fuel performance and safety, has been developed at HANARO (High-flux Advanced Neutron Application Reactor). The irradiation test of the first instrumented fuel capsule was carried out in March 2003 and the irradiation test of the second instrumented fuel capsule was carried out in April 2004 at HANARO. Through the irradiation tests of the two capsules, the design specifications and safety of the instrumented fuel capsule were successfully verified. In the first instrumented fuel capsule, only the technologies for measuring the center temperature of the nuclear fuel and neutron flux were implemented. In the second instrumented fuel capsule, the technologies for measuring the center temperature of the nuclear fuel, the internal pressure of the fuel rod, the elongation of the nuclear fuel and the neutron flux were implemented. Currently the dual instrumented technologies that alloy for two characteristics to be measured simultaneously in one fuel rod, is being developed. The duel instrumented fuel rods have been successfully designed as a part of the technology enhancement program for the instrumented fuel capsule. The instrumented fuel capsule will be utilized for the development of nuclear fuel. The instrumentation technologies for measuring the nuclear fuel characteristics will be applied to the 3-pin FTL (Fuel Test Loop) facility which is currently being developed. And, the duel instrumented technologies will contribute to enhancing the efficiency of the irradiation test using an instrumented fuel capsule at HANARO. (author)

  13. Capsule endoscopy in acute upper gastrointestinal hemorrhage: a prospective cohort study.

    Science.gov (United States)

    Gralnek, I M; Ching, J Y L; Maza, I; Wu, J C Y; Rainer, T H; Israelit, S; Klein, A; Chan, F K L; Ephrath, H; Eliakim, R; Peled, R; Sung, J J Y

    2013-01-01

    Capsule endoscopy may play a role in the evaluation of patients presenting with acute upper gastrointestinal hemorrhage in the emergency department. We evaluated adults with acute upper gastrointestinal hemorrhage presenting to the emergency departments of two academic centers. Patients ingested a wireless video capsule, which was followed immediately by a nasogastric tube aspiration and later by esophagogastroduodenoscopy (EGD). We compared capsule endoscopy with nasogastric tube aspiration for determination of the presence of blood, and with EGD for discrimination of the source of bleeding, identification of peptic/inflammatory lesions, safety, and patient satisfaction. The study enrolled 49 patients (32 men, 17 women; mean age 58.3 ± 19 years), but three patients did not complete the capsule endoscopy and five were intolerant of the nasogastric tube. Blood was detected in the upper gastrointestinal tract significantly more often by capsule endoscopy (15 /18 [83.3 %]) than by nasogastric tube aspiration (6 /18 [33.3 %]; P = 0.035). There was no significant difference in the identification of peptic/inflammatory lesions between capsule endoscopy (27 /40 [67.5 %]) and EGD (35 /40 [87.5 %]; P = 0.10, OR 0.39 95 %CI 0.11 - 1.15). Capsule endoscopy reached the duodenum in 45 /46 patients (98 %). One patient (2.2 %) had self-limited shortness of breath and one (2.2 %) had coughing on capsule ingestion. In an emergency department setting, capsule endoscopy appears feasible and safe in people presenting with acute upper gastrointestinal hemorrhage. Capsule endoscopy identifies gross blood in the upper gastrointestinal tract, including the duodenum, significantly more often than nasogastric tube aspiration and identifies inflammatory lesions, as well as EGD. Capsule endoscopy may facilitate patient triage and earlier endoscopy, but should not be considered a substitute for EGD. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water

    Energy Technology Data Exchange (ETDEWEB)

    Nussinovitch, A., E-mail: amos.nussi@mail.huji.ac.il; Dagan, O.

    2015-12-15

    Highlights: • Novel liquid-core capsules with a non-crosslinked alginate core were produced. • Capsules demonstrated highest efficiency adsorption of ∼300 mg Pb{sup 2+}/g alginate. • Regeneration was carried out by suspending capsules in 1 M HNO{sub 3} for 24 h. • Adsorption capacities of the capsules followed the order: Pb{sup 2+} > Cu{sup 2+} > Cd{sup 2+} > Ni{sup 2+}. - Abstract: Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan–alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb{sup 2+}/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb{sup +2}/g dry alginate vs. 267 mg Pb{sup +2}/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules’ ability to adsorb other heavy-metal cations – copper (Cu{sup 2+}), cadmium (Cd{sup 2+}) and nickel (Ni{sup 2+}) – was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation’s affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1 M nitric acid suspension for 24 h. Capsules could undergo three regeneration cycles before becoming damaged.

  15. Diagnosis of Ascaris lumbricoides infection using capsule endoscopy.

    Science.gov (United States)

    Yamashita, Eduardo Tomohissa; Takahashi, Wagner; Kuwashima, Daniel Yuiti; Langoni, Tiago Ribeiro; Costa-Genzini, Adriana

    2013-04-16

    Ascaris lumbricoides (A. lumbricoides) is the most common intestinal roundworm parasite, infecting approximately one quarter of the world's population. Infection can lead to various complications because it can spread along the gastrointestinal tract. Although A. lumbricoides infection is a serious healthcare issue in developing countries, it now also has a worldwide distribution as a result of increased immigration and travel. Intestinal obstruction is the most common complication of A. lumbricoides infection, potentially leading to even more serious consequences such as small bowel perforation and peritonitis. Diagnosis is based primarily on stool samples and the patient's history. Early diagnosis, aided in part by knowledge of the local prevalence, can result in early treatment, thereby preventing surgical complications associated with intestinal obstruction. Further, delay in diagnosis may have fatal consequences. Capsule endoscopy can serve as a crucial, non-invasive diagnostic tool for A. lumbricoides infection, especially when other diagnostic methods have failed to detect the parasite. We report a case of A. lumbricoides infection that resulted in intestinal obstruction at the level of the ileum. Both stool sample examination and open surgery failed to indicate the presence of A. lumbricoides, and the cause of the obstruction was only revealed by capsule endoscopy. The patient was treated with anthelmintics.

  16. Theoretical study of symmetry of flux onto a capsule

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Hao; Wu, Changshu; Zou, Shiyang, E-mail: duan-hao@iapcm.ac.cn [Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China); Pei, Wenbing [Shanghai Institute of Laser Plasma, China Academy of Engineering Physics, Shanghai 201800 (China)

    2015-09-15

    An analytic model to describe the flux asymmetry onto a capsule based on the viewfactor approximation is developed and verified with numerical simulations. By using a nested spheres technique to represent the various sources of flux asymmetry, the model can treat spherically and cylindrically symmetric hohlraums, e.g., cylinder, elliptic, and rugby. This approach includes the more realistic case of frequency-dependent flux asymmetry compared with the more standard frequency-integrated or single-frequency approaches [D. W. Phillion and S. M. Pollaine, Phys. Plasmas 1, 2963 (1994)]. Correspondingly, the approach can be used to assess x-ray preheat asymmetry generated from localized laser absorption in the high-Z hohlraum wall. For spherical hohlraums with 4, 6, or 8 laser entrance holes (LEHs), an optimal configuration of LEHs, laser spot placement, and angle-of-incidence of the single-ringed laser beams is defined. An analogy between minimizing the flux asymmetry onto a capsule and the Thomson problem of point charge placement on a sphere for minimized energy is shown.

  17. Theoretical study of symmetry of flux onto a capsule

    International Nuclear Information System (INIS)

    Duan, Hao; Wu, Changshu; Zou, Shiyang; Pei, Wenbing

    2015-01-01

    An analytic model to describe the flux asymmetry onto a capsule based on the viewfactor approximation is developed and verified with numerical simulations. By using a nested spheres technique to represent the various sources of flux asymmetry, the model can treat spherically and cylindrically symmetric hohlraums, e.g., cylinder, elliptic, and rugby. This approach includes the more realistic case of frequency-dependent flux asymmetry compared with the more standard frequency-integrated or single-frequency approaches [D. W. Phillion and S. M. Pollaine, Phys. Plasmas 1, 2963 (1994)]. Correspondingly, the approach can be used to assess x-ray preheat asymmetry generated from localized laser absorption in the high-Z hohlraum wall. For spherical hohlraums with 4, 6, or 8 laser entrance holes (LEHs), an optimal configuration of LEHs, laser spot placement, and angle-of-incidence of the single-ringed laser beams is defined. An analogy between minimizing the flux asymmetry onto a capsule and the Thomson problem of point charge placement on a sphere for minimized energy is shown

  18. Isokinetic characteristics of shoulder rotators in patients with adhesive capsulitis.

    Science.gov (United States)

    Lin, Hsiu-Chen; Li, Jing-Sheng; Lo, Sui-Foon; Shih, Yi-Fen; Lo, Chen-Yu; Chen, Shu-Ya

    2009-06-01

    To demonstrate the muscle strength characteristics of shoulder internal and external rotators and the effects of isokinetic exercise on muscle activity in patients with adhesive capsulitis. Cohort study with control subjects. Eight patients with adhesive capsulitis and 8 controls. Maximal isometric and isokinetic strength tests of shoulder internal and external rotators in the scapular plane were carried out. Muscle activities of the rotators were recorded in resting and during maximal isometrics. Muscle strength variables (peak torque, total work and power) and myoelectric variables (resting root-mean-square amplitude pre- and post-tests and the external-internal rotator co-activity in resting and during isometric contractions) were recorded. A mixed repeated-measure analysis of variance test was used to examine the within-group and between-group differences. For affected shoulders, smaller isometric average torque of internal rotators and high-speed peak torque, total work and power of external rotator were observed. The external/internal rotator ratio of peak torque in high-speed testing also exhibited significant decrease. The myoelectric variables showed no significant changes. High-speed external rotator strength and isometric internal rotator strength of the affected shoulders were decreased significantly. Isokinetic exercise may not increase the resting muscle activities and co-activity. These results provide a reference in planning muscle strengthening programmes and goals for these patients.

  19. Simulation of instability growth on ICF capsule ablators

    Science.gov (United States)

    Niasse, Nicolas; Chittenden, Jeremy

    2014-10-01

    It is believed that the ablation-front instabilities are mainly responsible for the hot-spot mix that impacts the performance of ICF capsules. Understanding the formation of these instabilities is therefore a first step towards a better control of the implosion dynamics and the optimization of the fusion yield. Using the Chimera code currently in development at Imperial College, we have performed several spherical wedge simulations of the low and high adiabat ablation phase pre-imposing different single-mode 2D and 3D perturbations on the capsule surface. Synthetic Sc, Fe and V X-ray backlighter images are generated by the Spk code and used to measure the growth of modes 30-160 with initial amplitude <= 3.4 μm PTV. The growth of imposed 2D perturbations is assessed for both low-foot and high-foot radiation pulse shapes on the National Ignition Facility. Results showing the merger of spike and bubble structures in multi-mode perturbations in both 2D and 3D simulations are explored and preliminary assessments of the difference between 2D and 3D non-linear behaviour is discussed. The sensitivity of shock timing to NLTE changes in opacity is also assessed.

  20. Theoretical study of symmetry of flux onto a capsule

    Science.gov (United States)

    Duan, Hao; Wu, Changshu; Pei, Wenbing; Zou, Shiyang

    2015-09-01

    An analytic model to describe the flux asymmetry onto a capsule based on the viewfactor approximation is developed and verified with numerical simulations. By using a nested spheres technique to represent the various sources of flux asymmetry, the model can treat spherically and cylindrically symmetric hohlraums, e.g., cylinder, elliptic, and rugby. This approach includes the more realistic case of frequency-dependent flux asymmetry compared with the more standard frequency-integrated or single-frequency approaches [D. W. Phillion and S. M. Pollaine, Phys. Plasmas 1, 2963 (1994)]. Correspondingly, the approach can be used to assess x-ray preheat asymmetry generated from localized laser absorption in the high-Z hohlraum wall. For spherical hohlraums with 4, 6, or 8 laser entrance holes (LEHs), an optimal configuration of LEHs, laser spot placement, and angle-of-incidence of the single-ringed laser beams is defined. An analogy between minimizing the flux asymmetry onto a capsule and the Thomson problem of point charge placement on a sphere for minimized energy is shown.

  1. Performance of HTGR fuel in HFIR capsule HT-33

    International Nuclear Information System (INIS)

    Tiegs, T.N.; Robbins, J.M.

    1979-06-01

    Irradiation capsule HT-33 was a cooperative effort between General Atomic Company (GA) and Oak Ridge National Laboratory (ORNL). In this capsule ThO 2 particles (fabricated by GA), low-enriched uranium particles, inert carbon particles, and various fuel rod matrices were tested under accelerated irradiation in the High-Flux Isotope Reactor. Visual examination showed good irradiation behavior for fuel rods with slug-injected matrices (using a pitch binder) and warm-molded matrices (using a thermosetting resin binder). Rod debonding improved somewhat with fuel rods that used GLCC H-451 ground graphite shim particles rather than Speer fluid coke shim particles. Measurements of permeability (by inert gas intrusion) of the pyrocarbon on the inert particles showed that the disorder created by the neutron flux did not increase the inert gas permeability. Metallographic examination of Triso-coated particles irradiated both with and without an outer pyrocarbon coating revealed that the outer coating is necessary to suppress SiC degradation at temperatures above approximately 1375 0 C. The fission product behavior (determined by the electron microprobe) was similar in both low-enriched and high-enriched uranium particles made from weak-acid resins. Furthermore, fission product palladium caused severe SiC corrosion at time-averaged temperatures above 1400 0 C

  2. Generic feature learning for wireless capsule endoscopy analysis.

    Science.gov (United States)

    Seguí, Santi; Drozdzal, Michal; Pascual, Guillem; Radeva, Petia; Malagelada, Carolina; Azpiroz, Fernando; Vitrià, Jordi

    2016-12-01

    The interpretation and analysis of wireless capsule endoscopy (WCE) recordings is a complex task which requires sophisticated computer aided decision (CAD) systems to help physicians with video screening and, finally, with the diagnosis. Most CAD systems used in capsule endoscopy share a common system design, but use very different image and video representations. As a result, each time a new clinical application of WCE appears, a new CAD system has to be designed from the scratch. This makes the design of new CAD systems very time consuming. Therefore, in this paper we introduce a system for small intestine motility characterization, based on Deep Convolutional Neural Networks, which circumvents the laborious step of designing specific features for individual motility events. Experimental results show the superiority of the learned features over alternative classifiers constructed using state-of-the-art handcrafted features. In particular, it reaches a mean classification accuracy of 96% for six intestinal motility events, outperforming the other classifiers by a large margin (a 14% relative performance increase). Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Positron Radiography of Ignition-Relevant ICF Capsules

    Science.gov (United States)

    Williams, Jackson; Chen, Hui; Field, John; Landen, Nino; Strozzi, David

    2017-10-01

    X-ray and neutron radiography are currently used to infer residual ICF shell and fuel asymmetries and areal density non-uniformities near and at peak compression that can impede ignition. Charged particles offer an alternative probe source that, in principle, are capable of radiographing the shell shape and areal density at arbitrary times, even in the presence of large x-ray self-emission. Laser-generated positrons are evaluated as a source to radiograph ICF capsules where current ultraintense laser facilities are capable of producing 2 ×1012 relativistic positrons in a narrow energy bandwidth and short duration. Monte Carlo simulations suggest that both the areal density and shell radius can be reconstructed for ignition-relevant capsules conditions between 0.002-2 g/cm2, and that this technique might be better suited to direct-drive. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and funded by the LDRD Program under project tracking code 17-ERD-010.

  4. Gamma-based Measurement of ``Dark Mix'' in ICF Capsules

    Science.gov (United States)

    Meaney, Kevin; Herrmann, H.; Kim, Yh; Zylstra, Ab; Geppert-Kleinrath, H.; Hoffman, Nm; Yi, As

    2017-10-01

    Mix of capsule ablator material into the fusion fuel is a source of yield degradation in inertial confinement fusion. Jetting or chunk mix, such as the elusive ``meteors'' that have been observed at NIF, can be difficult to diagnose because the chunks may not get hot enough to excite dopant x-rays, nor atomized enough for separated-reactants to fuse. Using the gamma reaction history (GRH-6m) diagnostic, (n,n') gammas from strategically placed carbon layer within a beryllium capsule gives a measure of the time-resolved areal density of this carbon during the burn and hence an indication of the compression and spatial distribution of this layer. As the carbon moves further from the fuel, the areal density nominally decreases as 1/r2 for unablated material. However, mix of this carbon into the cold dense fuel layer or hot spot will have a significant effect on the carbon gamma signal. Different types of mix (e.g., jetting, Rayleigh-Taylor fingers, diffusive, ...) as well as features that can seed this mix (eg., tents, fill,...) will be discussed along with their expected effect on the carbon signal. The design for upcoming OMEGA shots, which will demonstrate this technique, and the potential for use on the NIF will be presented.

  5. Reduction of capsule endoscopy reading times by unsupervised image mining.

    Science.gov (United States)

    Iakovidis, D K; Tsevas, S; Polydorou, A

    2010-09-01

    The screening of the small intestine has become painless and easy with wireless capsule endoscopy (WCE) that is a revolutionary, relatively non-invasive imaging technique performed by a wireless swallowable endoscopic capsule transmitting thousands of video frames per examination. The average time required for the visual inspection of a full 8-h WCE video ranges from 45 to 120min, depending on the experience of the examiner. In this paper, we propose a novel approach to WCE reading time reduction by unsupervised mining of video frames. The proposed methodology is based on a data reduction algorithm which is applied according to a novel scheme for the extraction of representative video frames from a full length WCE video. It can be used either as a video summarization or as a video bookmarking tool, providing the comparative advantage of being general, unbounded by the finiteness of a training set. The number of frames extracted is controlled by a parameter that can be tuned automatically. Comprehensive experiments on real WCE videos indicate that a significant reduction in the reading times is feasible. In the case of the WCE videos used this reduction reached 85% without any loss of abnormalities.

  6. Light-Responsive Polymer Micro- and Nano-Capsules

    Directory of Open Access Journals (Sweden)

    Valentina Marturano

    2016-12-01

    Full Text Available A significant amount of academic and industrial research efforts are devoted to the encapsulation of active substances within micro- or nanocarriers. The ultimate goal of core–shell systems is the protection of the encapsulated substance from the environment, and its controlled and targeted release. This can be accomplished by employing “stimuli-responsive” materials as constituents of the capsule shell. Among a wide range of factors that induce the release of the core material, we focus herein on the light stimulus. In polymers, this feature can be achieved introducing a photo-sensitive segment, whose activation leads to either rupture or modification of the diffusive properties of the capsule shell, allowing the delivery of the encapsulated material. Micro- and nano-encapsulation techniques are constantly spreading towards wider application fields, and many different active molecules have been encapsulated, such as additives for food-packaging, pesticides, dyes, pharmaceutics, fragrances and flavors or cosmetics. Herein, a review on the latest and most challenging polymer-based micro- and nano-sized hollow carriers exhibiting a light-responsive release behavior is presented. A special focus is put on systems activated by wavelengths less harmful for living organisms (mainly in the ultraviolet, visible and infrared range, as well as on different preparation techniques, namely liposomes, self-assembly, layer-by-layer, and interfacial polymerization.

  7. Blood detection in wireless capsule endoscopy using expectation maximization clustering

    Science.gov (United States)

    Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.

    2006-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.

  8. Motion analysis for duplicate frame removal in wireless capsule endoscope

    Science.gov (United States)

    Lee, Hyun-Gyu; Choi, Min-Kook; Lee, Sang-Chul

    2011-03-01

    Wireless capsule endoscopy (WCE) has been intensively researched recently due to its convenience for diagnosis and extended detection coverage of some diseases. Typically, a full recording covering entire human digestive system requires about 8 to 12 hours for a patient carrying a capsule endoscope and a portable image receiver/recorder unit, which produces 120,000 image frames on average. In spite of the benefits of close examination, WCE based test has a barrier for quick diagnosis such that a trained diagnostician must examine a huge amount of images for close investigation, normally over 2 hours. The main purpose of our work is to present a novel machine vision approach to reduce diagnosis time by automatically detecting duplicated recordings caused by backward camera movement, typically containing redundant information, in small intestine. The developed technique could be integrated with a visualization tool which supports intelligent inspection method, such as automatic play speed control. Our experimental result shows high accuracy of the technique by detecting 989 duplicate image frames out of 10,000, equivalently to 9.9% data reduction, in a WCE video from a real human subject. With some selected parameters, we achieved the correct detection ratio of 92.85% and the false detection ratio of 13.57%.

  9. Ultrasound-guided interventional release of rotator interval and posteroinferior capsule for adhesive capsulitis of the shoulder using a specially designed needle.

    Science.gov (United States)

    Ahn, Kang; Jhun, Hyung-Joon; Choi, Kyung-Man; Lee, Yong-Seung

    2011-01-01

    Adhesive capsulitis is a common but poorly understood disorder of the shoulder. Various treatments have been developed to manage this condition, but the efficacy of these treatments is controversial. We developed an ultrasound-guided, minimally invasive interventional technique to manage adhesive capsulitis of the shoulder using a specially designed needle. To describe the methodological approach of our intervention. Technical report. Pain management clinic. Thirteen participants with adhesive capsulitis of the shoulder underwent ultrasound-guided interventional release of the rotator interval and posteroinferior capsule using a specially designed curved Round Needle. A convex ultrasound probe was placed along the oblique coronal plane over the supraspinatus muscle and acromion. Under ultrasonographic guidance, the needle was passed through the supraspinatus muscle and superior labrum and reached the rotator interval. It was moved forward and backward until no resistance was felt. After finishing the rotator interval release, the needle was inserted toward the posteroinferior capsule. While the operator released the adhesion in the posteroinferior capsule by moving the needle forward and backward, an assistant gradually abducted the shoulder. When full abduction of the affected shoulder was achieved, the intervention was completed.   Following our intervention, significant improvements in pain levels, glenohumeral range of motion, and Quick Disability of the Arm, Shoulder, and Hand scores were attained at follow-up. Technical report only. Efficacy of this technique is beyond the scope of the article. Ultrasound-guided interventional release of the rotator interval and posteroinferior capsule appears to have clinical significance in the management of adhesive capsulitis of the shoulder.

  10. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Tin-coated lead foil capsules for wine bottles. 189... lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one... covering applied over the cork and neck areas) on wine bottles to prevent insect infestation, as a barrier...

  11. Improved Water Barrier Properties of Calcium Alginate Capsules Modified by Silicone Oil

    Directory of Open Access Journals (Sweden)

    Brian G. Zukas

    2016-04-01

    Full Text Available Calcium alginate films generally offer poor diffusion resistance to water. In this study, we present a technique for encapsulating aqueous drops in a modified calcium alginate membrane made from an emulsion of silicone oil and aqueous alginate solution and explore its effect on the loss of water from the capsule cores. The capsule membrane storage modulus increases as the initial concentration of oil in the emulsion is increased. The water barrier properties of the fabricated capsules were determined by observing the mass loss of capsules in a controlled environment. It was found that capsules made with emulsions containing 50 wt% silicone oil were robust while taking at least twice the time to dry completely as compared to capsules made from only an aqueous alginate solution. The size of the oil droplets in the emulsion also has an effect on the water barrier properties of the fabricated capsules. This study demonstrates a facile method of producing aqueous core alginate capsules with a modified membrane that improves the diffusion resistance to water and can have a wide range of applications.

  12. Effects of plasma physics on capsule implosions in gas-filled hohlraums

    Energy Technology Data Exchange (ETDEWEB)

    Lindman, E.L.; Delamater, N.D.; Magelssen, G.R.; Hauer, A.

    1994-10-01

    Initial experiments on capsule implosions in gas-filled hohlraums have been carried out on the NOVA Laser at Lawrence Livermore National Laboratory. Observed capsule shapes from preliminary experiments are more oblate than predicted. Improvements in modeling required to calculate these experiments and additional experiments are being pursued.

  13. Deformation of ovalbumin-alginate capsules in a T-Junction

    Science.gov (United States)

    Häner, Edgar; Juel, Anne

    2015-11-01

    We study experimentally the flow-induced deformation of liquid-filled ovalbumin-alginate capsules in a T-junction. In applications, capsules/cells often negotiate branched networks with junctions thus experiencing large deformations. We investigate the constant volume-flux viscous flow of buoyancy-neutral thin-walled capsules close to the centreline of rectangular channels, by comparison to near-rigid gelled beads. The motion of the capsules in straight channels scales with the capillary number - the ration of viscous to elastic forces. However, the effect of elastic deformation on the motion is sufficiently weak that a rigid sphere model predicts the velocity of capsules with diameters of up to 70% of that of the channel to within 5%. In the T-junction, systematic selection of daughter channel (right-left) occurs outside a finite region around the channel centreline, by contrast with near-rigid gelled beads, where the actual centreline is the separator. We quantify the behaviour of capsules in terms of their longitudinal stretching (up to a factor of three without rupture). We show the large range of deformations encountered can be applied to the measurement of the elastic properties of capsules as well as to the geometric-induced sorting and manipulation of capsules.

  14. Acromioclavicular joint pain in patients with adhesive capsulitis: a prospective outcome study.

    Science.gov (United States)

    Anakwenze, Oke A; Hsu, Jason E; Kim, Jae S; Abboud, Joseph A

    2011-09-09

    Diagnosis of adhesive capsulitis is a clinical diagnosis based on history and physical examination. Afflicted patients exhibit active and passive loss of motion in all planes and a positive capsular stretch sign. The effect of adhesive capsulitis on acromioclavicular biomechanics leading to tenderness has not been documented in the literature. This study reports on the incidence of acromioclavicular tenderness in the presence of adhesive capsulitis. Furthermore, we note the natural history of such acromioclavicular joint pain in relation to that of adhesive capsulitis. Over a 2-year period (2005-2007), 84 patients undergoing initial evaluation for adhesive capsulitis were prospectively examined with the use of validated outcome measures and physical examination. Acromioclavicular joint tenderness results were compared and analyzed on initial evaluation and final follow-up of at least 1 year. Forty-eight patients (57%) with adhesive capsulitis had acromioclavicular joint pain on examination. At final follow-up, as range of motion improved, a significant increase in American Shoulder and Elbow Surgeons/Penn shoulder score and decrease in number of patients with acromioclavicular pain was noted with only 6 patients with residual pain (Padhesive capsulitis, there is not only compensatory scapulothoracic motion but also acromioclavicular motion. This often results in transient symptoms at the acromioclavicular joint, which abate as the frozen shoulder resolves and glenohumeral motion improves. This is important to recognize to avoid unnecessary invasive treatment of the acromioclavicular joint when the patient presents with adhesive capsulitis. Copyright 2011, SLACK Incorporated.

  15. Visual quality inspection of capsule heads utilizing shape and gray information

    Science.gov (United States)

    Wang, Qi; Zhang, Tie; Cai, Zhenlin; Jiang, Nan; Wu, Jiamei; Zhang, Xiangde

    2015-11-01

    Capsule quality inspection is important and necessary in the pharmaceutical industry. The popular methods often mis-detect capsule head defects. To solve this problem, we propose a high-quality visual defect inspection method for capsule heads. In detail, first, capsule head images are captured by high-speed cameras with ring illuminators. Then, radial symmetry transform (RST) is employed to locate region of interest (ROI). Next, the ROI image is enhanced by homomorphic filter and binarized by basic global thresholding. After that, six discriminative features of ROI are extracted, which are skeleton feature, binary density, number of connected boundaries, RST power, mean, and variance. Finally, these features are classified by support vector machine to inspect the quality of the capsule head. The experiment is carried out on a self-established capsule image database, Northeastern University Capsule Image Database Version 1.0. According to our experiment, the proposed method can detect ROI correctly for all of the capsule head images and inspection accuracy achieves a true positive rate of 100.00% and true negative rate of 100.00%.

  16. TEMPO-oxidized Konjac glucomannan as appliance for the preparation of hard capsules

    NARCIS (Netherlands)

    Chen, Yuying; Zhao, Huiying; Liu, Xianwu; Li, Zusen; Liu, Bin; Wu, Jiande; Shi, Mengxuan; Norde, Willem; Li, Yuan

    2016-01-01

    TEMPO-oxidized Konjac glucomannan (OKGM) was developed as new material for preparing vegetarian hard capsules. OKGM of different degrees of oxidation: DO30%, DO50%, and DO80% were prepared to select optimum DO for capsule formation. FT-IR results proved that the primary alcohol groups on KGM were

  17. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment.

    Directory of Open Access Journals (Sweden)

    Thanh Nho Do

    Full Text Available Intra-gastric balloons (IGB have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient's stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient's stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight.

  18. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  19. Potential of sago starch/carrageenan mixture as gelatin alternative for hard capsule material

    Science.gov (United States)

    Poeloengasih, Crescentiana Dewi; Pranoto, Yudi; Anggraheni, Frida Dwi; Marseno, Djagal Wiseso

    2017-03-01

    In order to replace gelatin in capsule shell production, blends of sago starch and carrageenan were developed. Films and capsules were prepared with 10% (w/v) of sago starch, 25% (w/w starch) of glycerol and various carrageenan concentration (1, 2, 3% w/w starch) in two different kappa/iota-carrageenan ratio (1:3 and 3:1). The resulted films and capsules were characterized by mechanical property, water vapor and oxygen permeability. In addition, moisture absorption and solubility of capsule in acid solution were investigated. The results reveal that addition of carrageenan makes the films stronger and less permeable. Higher kappa-carrageenan content improved tensile strength and barrier properties of the films, whereas higher iota-carrageenan content produced films with higher elongation, moisture absorption and capsule solubility in acid solution. Capsule with 2% (w/w starch) of carrageenan at kappa-/iota-ratio 3:1 had the lowest moisture absorption, whereas capsule with 3% (w/w starch) of carrageenan at kappa/iota ratio 1:3 had the highest solubility. It is illustrated that sago starch/carrageenan blends can be used as hard capsule material.

  20. Wireless Capsule Gastrointestinal Endoscopy: Direction-of-Arrival Estimation Based Localization Survey.

    Science.gov (United States)

    Dey, Nilanjan; Ashour, Amira S; Shi, Fuqian; Sherratt, R Simon

    2017-01-01

    One of the significant challenges in capsule endoscopy (CE) is to precisely determine the pathologies location. The localization process is primarily estimated using the received signal strength (RSS) from sensors in the capsule system through its movement in the gastrointestinal (GI) tract. Consequently, the wireless CE (WCE) system requires improvement to handle the lack of the capsule instantaneous localization information and to solve the relatively low transmission data rate challenges. Furthermore, the association among the capsule's transmitter position, capsule location, signal reduction, and the capsule direction should be assessed. These measurements deliver significant information for the instantaneous capsule localization systems based on time-of-arrival approach, phase difference of arrival, RSS, electromagnetic, direction of arrival (DOA), and video tracking approaches are developed to locate the WCE precisely. This review introduces the acquisition concept of the GI medical images using the endoscopy with a comprehensive description of the endoscopy system components. Capsule localization and tracking are considered to be the most important features of the WCE system, thus this paper emphasizes the most common localization systems generally, highlighting the DOA-based localization systems and discusses the required significant research challenges to be addressed.