WorldWideScience

Sample records for aneurysm open repair

  1. Abdominal aortic aneurysm repair - open

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007392.htm Abdominal aortic aneurysm repair - open To use the sharing features on this page, please enable JavaScript. Open abdominal aortic aneurysm repair is surgery to fix a widened part ...

  2. Abdominal aortic aneurysm repair - open - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000240.htm Abdominal aortic aneurysm repair - open - discharge To use the sharing features ... References Orandi BJ, Black JH. Open repair of abdominal aortic aneurysms. In: Cameron JL, Cameron AM, eds. Current Surgical ...

  3. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  4. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim;

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  5. National trends for open and endovascular repair of aneurysms in Korea: 2004-2013.

    Science.gov (United States)

    Joh, Jin Hyun; Park, Yun-Young; Cho, Sung-Shin; Park, Ho-Chul

    2016-11-01

    The introduction of endovascular aneurysm repair has led to a dramatic decline in open aneurysm repair. The aim of this report was to evaluate Korean national trends for the treatment of aneurysms. A serial, cross-sectional study of time trends of patients who underwent aneurysm repair between 2004 and 2013 was conducted. Data from the Health Insurance Review and Assessment Service were used to evaluate the trends of aneurysm repair in the Korean population and to analyze the trends of open and endovascular aneurysm repair among Medicare beneficiaries. A linear-by-linear association was performed to determine alterations in the rates at which these aneurysm repair techniques were performed. A total of 32,130 patients underwent aneurysm repair between 2004 and 2013. The proportion of patients who underwent open repair decreased from 94.0% in 2004 to 54.9% in 2013; whereas the proportion of patients who underwent endovascular repair increased from 6.0% in 2004 to 45.1% in 2013. During the study period, the number of patients undergoing endovascular repair of aortic aneurysms significantly increased from 82 to 1,396 (relative risk, 16.17; 95% confidence interval: 12.94-20.21). Endovascular repair of abdominal aortic aneurysms (AAAs)overtook open repair between 2010 and 2011. The frequency of open aneurysm repair increased 1.2-fold, with an overall downward trend. The prevalence of endovascular repair markedly increased 15.3-fold. These findings indicated that, in Korea, the endovascular repair of AAAs overtook open repair as the most common technique between 2010 and 2011.

  6. Iliac branched device implantation in tortuous iliac anatomy after previous open ruptured aortic aneurysm repair

    NARCIS (Netherlands)

    Vourliotakis, G.; Bracale, U. M.; Sondakh, A.; Tielliu, I. F. J.; Prins, T. R.; Verhoeven, E. L. G.

    2012-01-01

    The aim of this paper was to present iliac branched device (IBD) implantation in a fit 67-year-old man with tortuous iliac anatomy after previous emergent open abdominal aortic aneurysm (AAA) repair. The patient underwent open treatment for a ruptured abdominal aortic aneurysm in another hospital. T

  7. Aortic aneurysm repair - endovascular

    Science.gov (United States)

    EVAR; Endovascular aneurysm repair - aorta; AAA repair - endovascular; Repair - aortic aneurysm - endovascular ... Endovascular aortic repair is done because your aneurysm is very large, growing quickly, or is leaking or bleeding. You may have ...

  8. Imaging and management of complications of open surgical repair of abdominal aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Nayeemuddin, M. [Department of Interventional Radiology, City General Hospital, University Hospital of North Staffordshire NHS Trust, Stoke-On-Trent (United Kingdom); Pherwani, A.D. [Department of Vascular Surgery, City General Hospital, University Hospital of North Staffordshire NHS Trust, Stoke-On-Trent (United Kingdom); Asquith, J.R., E-mail: john.asquith@uhns.nhs.uk [Department of Interventional Radiology, City General Hospital, University Hospital of North Staffordshire NHS Trust, Stoke-On-Trent (United Kingdom)

    2012-08-15

    Open repair is still considered the reference standard for long-term repair of abdominal aortic aneurysms (AAA). In contrast to endovascular aneurysm repair (EVAR), patients with open surgical repair of AAA are not routinely followed up with imaging. Although complications following EVAR are widely recognized and routinely identified on follow-up imaging, complications also do occur following open surgical repair. With frequent use of multi-slice computed tomography (CT) angiography (CTA) in vascular patients, there is now improved recognition of the potential complications following open surgical repair. Many of these complications are increasingly being managed using endovascular techniques. The aim of this review is to illustrate a variety of potential complications that may occur following open surgical repair and to demonstrate their management using both surgical and endovascular techniques.

  9. A prospective clinical, economic, and quality-of-life analysis comparing endovascular aneurysm repair (EVAR), open repair, and best medical treatment in high-risk patients with abdominal aortic aneurysms suitable for EVAR: the Irish patient trial.

    LENUS (Irish Health Repository)

    Hynes, Niamh

    2007-12-01

    To report the results of a trial comparing endovascular aneurysm repair (EVAR) to open repair (OR) and best medical therapy (BMT) involving high-risk patients with abdominal aortic aneurysms (AAA) suitable for EVAR.

  10. Long-term durability of open thoracic and thoracoabdominal aneurysm repair.

    Science.gov (United States)

    Fischbein, Michael P; Miller, D Craig

    2009-06-01

    Results of open surgical repair of descending and thoracoabdominal aortic aneurysms have improved dramatically over the years. Nevertheless, while adjunctive protective strategies, such as spinal cord drainage and distal aortic perfusion, have improved outcomes, clinical challenges remain. In the current era, thoracic aortic surgeons must possess both open and endovascular stent-graft capabilities to offer these complex patients the most optimal and individualized treatment approach. Herein we summarize the contemporary outcomes of open surgical repair of patients with either descending thoracic or thoracoabdominal aortic aneurysms, focusing on the risk of complications and means for preventing their occurrence.

  11. Prediction of 30-day mortality after endovascular repair or open surgery in patients with ruptured abdominal aortic aneurysms.

    NARCIS (Netherlands)

    Visser, J.J.; Williams, M.A.; Kievit, J.; Bosch, J.L.; Hunink, M.G.M.; Teijink, J.A.; Verhoeven, E.L.; Smet, A.A. de; Geelkerken, R.H.; Steyerberg, E.W.; Sambeek, M.R. van

    2009-01-01

    OBJECTIVE: To validate the Glasgow Aneurysm Score (GAS) in patients with ruptured abdominal aortic aneurysms (AAAs) treated with endovascular repair or open surgery and to update the GAS so that it predicts 30-day mortality for patients with ruptured AAA treated with endovascular repair or open surg

  12. Long-term results of elective open repair for abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    WU Qing-hua; LUO Xiao-yun; KOU Lei

    2006-01-01

    @@ Abdominal aortic aneurysm (AAA) has a high propensity to rupture. Repair of AAA by conventional surgical replacement with a graft has been the standard of treatment since the mid 1960s.Because of advances in surgical, anaesthetic and intensive care techniques, the outcome of elective open AAA repair has improved constantly. However,with the improvement of endovascular techniques,the role of open repair is being challenged.1 More and more stents are being deployed in patients because of their less invasive characteristics.2 We reviewed our ten years of experience with elective open AAA repair and recent papers about endoluminal and open repair for AAA to discuss status and future of open repair for AAA in China.

  13. Emergent endovascular vs. open surgery repair for ruptured abdominal aortic aneurysms: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Chuan Qin

    Full Text Available OBJECTIVES: To systematically review studies comparing peri-operative mortality and length of hospital stay in patients with ruptured abdominal aortic aneurysms (rAAAs who underwent endovascular aneurysm repair (EVAR to patients who underwent open surgical repair (OSR. METHODS: The Medline, Cochrane, EMBASE, and Google Scholar databases were searched until Apr 30, 2013 using keywords such as abdominal aortic aneurysm, emergent, emergency, rupture, leaking, acute, endovascular, stent, graft, and endoscopic. The primary outcome was peri-operative mortality and the secondary outcome was length of hospital stay. RESULTS: A total of 18 studies (2 randomized controlled trials, 5 prospective studies, and 11 retrospective studies with a total of 135,734 rAAA patients were included. rAAA patients who underwent EVAR had significantly lower peri-operative mortality compared to those who underwent OSR (overall OR = 0.62, 95% CI = 0.58 to 0.67, P<0.001. rAAA patients with EVAR also had a significantly shorter mean length of hospital stay compared to those with OSR (difference in mean length of stay ranged from -2.00 to -19.10 days, with the overall estimate being -5.25 days (95% CI = -9.23 to -1.26, P = 0.010. There was no publication bias and sensitivity analysis showed good reliability. CONCLUSIONS: EVAR confers significant benefits in terms of peri-operative mortality and length of hospital stay. There is a need for more randomized controlled trials to compare outcomes of EVAR and OSR for rAAA.

  14. The "open branch" technique: A new way to prevent paraplegia after total endovascular repair of thoracoabdominal aneurysm.

    Science.gov (United States)

    Krajcer, Zvonimir; Echeverria, Angela

    2016-03-01

    Spinal cord ischemia (SCI) has been one of the most concerning complications after surgical and endovascular thoracoabdominal aortic aneurysm repair "Open Branch" is an innovative technique to reduce the incidence of SCI Further studies in a larger number of patients with varying pathologies are needed to confirm the advantages of this technique.

  15. Fenestrated and branched endograft repair of juxtarenal aneurysms after previous open aortic reconstruction

    NARCIS (Netherlands)

    Beck, Adam W.; Bos, Wendy T. G. J.; Vourliotakis, Georgios; Zeebregts, Clark J.; Tielliu, Ignace F. J.; Verhoeven, Eric L. G.

    2009-01-01

    Objective: Para-anastomotic aortic aneurysms and progressive aneurysmal degeneration of the aorta after previous open aortic reconstruction pose a challenging clinical scenario. Due to the proximity to the visceral arteries, endovascular exclusion is typically not an option. However, the development

  16. Thoracic aorta aneurysm open repair in heart transplant recipient; the anesthesiologist′s perspective

    Directory of Open Access Journals (Sweden)

    Fabrizio Monaco

    2016-01-01

    Full Text Available Many years following transplantation, heart transplant recipients may require noncardiac major surgeries. Anesthesia in such patients may be challenging due to physiological and pharmacological problems regarding allograft denervation and difficult immunosuppressive management. Massive hemorrhage, hypoperfusion, renal, respiratory failure, and infections are some of the most frequent complications related to thoracic aorta aneurysm repair. Understanding how to optimize hemodynamic and infectious risks may have a substantial impact on the outcome. This case report aims at discussing risk stratification and anesthetic management of a 54-year-old heart transplant female recipient, affected by Marfan syndrome, undergoing thoracic aorta aneurysm repair.

  17. Thoraco-abdominal aortic aneurysm branched repair

    NARCIS (Netherlands)

    Verhoeven, E. L. G.; Tielliu, I. F. J.; Ferreira, M.; Zipfel, B.; Adam, D. J.

    2010-01-01

    Open thoraco-abdominal aortic aneurysm repair is a demanding procedure with high impact on the patient and the operating team. Results from expert centres show mortality rates between 3-21%, with extensive morbidity including renal failure and paraplegia. Endovascular repair of abdominal aortic aneu

  18. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ziheng, E-mail: wuziheng303@hotmail.com [Zhejiang University, Department of Vascular Surgery, The First Affiliated Hospital, School of Medicine (China); Xu, Liang, E-mail: maxalive@163.com [Zhejiang University, Department of Neurosurgery, The Second Affiliated Hospital, School of Medicine (China); Qu, Lefeng, E-mail: qulefeng@gmail.com [The Second Military Medical University, Department of Vascular and Endovascular Surgery, Changzheng Hospital (China); Raithel, Dieter, E-mail: dieter.raithel@rzmail.uni-erlangen.de [Nuremberg Southern Hospital, Department of Vascular and Endovascular Surgery (Germany)

    2015-02-15

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

  19. Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years

    NARCIS (Netherlands)

    J. Powell (Janet); Sweeting, M.J.; Ulug, P.; Blankensteijn, J.D.; F.A. Lederle (Frank); Becquemin, J.-P.; Greenhalgh, R.M.; Greenhalgh, R.M.; J. Beard (James); M. Buxton (M.); Brown, L.C.; Harris, P.L.; Powell, J.T.; Rose, J.D.G.; Russell, I.T.; Sculpher, M.J.; S.G. Thompson (Simon); Lilford, R.J.; Bell, P.R.F.; Greenhalgh, R.M.; Whitaker, S.C.; Poole-Wilson, P.A.; Ruckley, C.V.; Campbell, W.B.; Dean, M.R.E.; Ruttley, M.S.T.; Coles, E.C.; Powell, J.T.; A. Halliday (A.); Gibbs, S.J.; Brown, L.C.; Epstein, D.; M. Sculpher (Mark); Thompson, S.G.; Hannon, R.J.; Johnston, L.; L.A. Bradbury (Linda); Henderson, M.J.; Parvin, S.D.; Shepherd, D.F.C.; Greenhalgh, R.M.; Mitchell, A.W.; Edwards, P.R.; Abbott, G.T.; Higman, D.J.; Vohra, A.; Ashley, S.; Robottom, C.; M. Wyatt (M.); Rose, J.D.G.; Byrne, D.; Edwards, R.; Leiberman, D.P.; McCarter, D.H.; Taylor, P.R.; Reidy, J.F.; Wilkinson, A.R.; D. Ettles (D.); Clason, A.E.; Leen, G.L.S.; Wilson, N.V.; Downes, M.; S. Walker (S.); Lavelle, J.M.; Gough, M.J.; McPherson, S.; D.J.A. Scott (D Julian); Kessell, D.O.; C.D. Naylor; I. Sayers (Ian); Fishwick, N.G.; Harris, P.L.; Gould, D.A.; Walker, M.G.; Chalmers, N.C.; Garnham, A.; Collins, M.A.; Beard, J.D.; P.A. Gaines (Peter); Ashour, M.Y.; Uberoi, R.; Braithwaite, B.; Whitaker, S.C.; Davies, J.N.; Travis, S.; Hamilton, G.; A. Platts (A.); Shandall, A.; Sullivan, B.A.; Sobeh, M.; Matson, M.; Fox, A.D.; Orme, R.; Yusef, W.; Doyle, T.; Horrocks, M.; Hardman, J.; Blair, P.H.B.; Ellis, P.K.; Morris, G.; Odurny, A.; Vohra, R.; Duddy, M.; M.J. Thompson (Matthew); Loosemore, T.M.L.; Belli, A.M.; Morgan, R.; Adiseshiah, M.; J. Brookes (J.); McCollum, C.N.; R. Ashleigh (R.); Aukett, M.; Baker, S.; Barbe, E.; Batson, N.; J.L. Bell (Jocelyn); Blundell, J.; Boardley, D.; Boyes, S.; Brown, O.; Bryce, J.; Carmichael, M.; Chance, T.; Coleman, J.; Cosgrove, C.; Curran, G.; Dennison, T.; Devine, C.; Dewhirst, N.; Errington, B.; Farrell, H.; Fisher, C.; Fulford, P.; Gough, M.; Graham, C.; Hooper, R.; Horne, G.; Horrocks, L.; Hughes, B.; Hutchings, T.; Ireland, M.; Judge, C.; Kelly, L.; Kemp, J.; Kite, A.; Kivela, M.; Lapworth, M.; Lee, C.; Linekar, L.; Mahmood, A.; March, L.; Martin, J.; Matharu, N.; McGuigen, K.; Morris-Vincent, P.; Murray, S.; Murtagh, A.; Owen, G.; Ramoutar, V.; Rippin, C.; Rowley, J.; Sinclair, J.; Spencer, S.; Taylor, V.; Tomlinson, C.; Ward, S.; Wealleans, V.; West, J.; White, K.; Williams, J.; Wilson, L.; D.E. Grobbee (Diederick); Blankensteijn, J.D.; Bak, A.A.A.; Buth, J.; P.M.T. Pattynama (Peter M.T.); Verhoeven, E.L.G.; van Voorthuisen, A.E.; Blankensteijn, J.D.; Balm, R.; Buth, J.; P.M.W. Cuypers (Philippe); D.E. Grobbee (Diederick); Prinssen, M.; M.H.R.M. van Sambeek (Marc H. R.); Verhoeven, E.L.G.; A.F. Baas (Annette); Hunink, M.G.; J.M. Engelshoven (Jos); M. Jacobs (Michael); B.A.J.M. de Mol; J.H. van Bockel; Balm, R.; J.A. Reekers (Jim); X. Tielbeek; E.L.G. Verhoeven (Eric); W. Wisselink; N. Boekema; Heuveling, L.M.; I. Sikking; M. Prinssen (Monique); R. Balm (Ron); J.D. Blankensteijn (Jan); J. Buth (Jaap); P.M.W. Cuypers (Philippe); van Sambeek, M.R.H.M.; Verhoeven, E.L.G.; J.L. de Bruin (Jorg); A.F. Baas (Annette); Blankensteijn, J.D.; Prinssen, M.; J. Buth (Jacob); A.V. Tielbeek (Alexander); J.D. Blankensteijn (Jan); R. Balm (Ron); Reekers, J.A.; M.R.H.M. van Sambeek (M. R H M); P.M.T. Pattynama (Peter); E.L.G. Verhoeven (Eric); T. Prins (T.); A.C. van der Ham; van der Velden, J.J.I.M.; S.M.M. van Sterkenburg (S. M M); G.B. ten Haken (G.); C.M.A. Bruijninckx; H. van Overhagen (H.); R.P. Tutein Nolthenius; C. Hendriksz (Chris); J.A.W. Teijink (J. A W); H.F. Odink (H.); A.A. de Smet (André); D. Vroegindeweij (Dammis); R.M.M. van Loenhout (R. M M); M.J. Rutten (M.); J.F. Hamming (Jaap); L.E.H. Lampmann (L. E H); M.H.M. Bender (M. H M); S.G.M.A. Pasmans (Suzanne); A. Vahl (Anco); C. de Vries (Cees); A.J. Mackaay (Albert); L. van Dortmont (Laura); van der Vliet, A.J.; L.J. Schultze Kool (L.); J.B.B. Boomsma (J. B B); H.R. van Dop (H.); J.C.A. de Mol van Otterloo (J. C A); T.P.W. de Rooij (T. P W); T.M. Smits (T.); P. Yilmaz (Pinar); Wisselink, W.; F.G. van den Berg (Fred); M.J.T. Visser (M. J T); E. van der Linden (Edwin); G.W. Schurink; M.G. Haan (Michiel); H.J. Smeets (Harm); Stabel, P.; F. van Elst (F.); J. Poniewierski (J.); F. Vermassen (Frank); Lederle, F.A.; Freischlag, J.A.; Kohler, T.R.; Latts, E.; Matsumura, J.; Padberg, F.T.; Kyriakides, T.C.; Swanson, K.M.; Guarino, P.; Peduzzi, P.; Antonelli, M.; Cushing, C.; Davis, E.; Durant, L.; Joyner, S.; Kossack, A.; Kyriakides, T.C.; LeGwin, M. (Mary); McBride, V.; O'Connor, T.; Poulton, J.; Stratton, S.; Zellner, S.; Snodgrass, A.J.; Thornton, J.; Swanson, K.M.; Haakenson, C.M.; Stroupe, K.T.; Jonk, Y.; Hallett, J.W.; Hertzer, N.; Towne, J.; Katz, D.A.; Karrison, T.; Matts, J.P.; Marottoli, R.; Kasl, S.; Mehta, R.; Feldman, R.; Farrell, W.; Allore, H.; Perry, E.; Niederman, J.; Randall, F.; Zeman, M.; Beckwith, D.; O'Leary, T.J.; Huang, G.D.; Latts, E.; Bader, M.; Ketteler, E.R.; Kingsley, D.D.; Marek, J.M.; Massen, R.J.; Matteson, B.D.; Pitcher, J.D.; Langsfeld, M.; Corson, J.D.; Goff, J.M.; Kasirajan, K.; Paap, C.; Robertson, D.C.; Salam, A.; Veeraswamy, R.; Milner, R.; Kasirajan, K.; Guidot, J.; Lal, B.K.; Busuttil, S.J.; Lilly, M.P.; Braganza, M.; Ellis, K.; Patterson, M.A.; Jordan, W.D.; Whitley, D.; Taylor, S.; Passman, M.; Kerns, D.; Inman, C.; Poirier, J.; Ebaugh, J.; Raffetto, J.; Chew, D.; Lathi, S.; Owens, C.; Hickson, K.; Dosluoglu, H.H.; Eschberger, K.; Kibbe, M.R.; Baraniewski, H.M.; Matsumura, J.; Endo, M.; Busman, A.; Meadows, W.; Evans, M.; Giglia, J.S.; El Sayed, H.; Reed, A.B.; Ruf, M.; Ross, S.; Jean-Claude, J.M.; Pinault, G.; Kang, P.; White, N.; Eiseman, M.; Jones, R.; Timaran, C.H.; Modrall, J.G.; Welborn, M.B.; Lopez, J.; Nguyen, T.; Chacko, J.K.Y.; Granke, K.; Vouyouka, A.G.; Olgren, E.; Chand, P.; Allende, B.; Ranella, M.; Yales, C.; Whitehill, T.A.; Krupski, W.C.; Nehler, M.R.; Johnson, S.P.; Jones, D.N.; Strecker, P.; Bhola, M.A.; Shortell, C.K.; Gray, J.L.; Lawson, J.H.; McCann, R.; Sebastian, M.W.; Kistler Tetterton, J.; Blackwell, C.; Prinzo, P.A.; Lee, N.; Padberg, F.T.; Cerveira, J.J.; Lal, B.K.; Zickler, R.W.; Hauck, K.A.; Berceli, S.A.; Lee, W.A.; Ozaki, C.K.; Nelson, P.R.; Irwin, A.S.; Baum, R.; Aulivola, B.; Rodriguez, H.; Littooy, F.N.; Greisler, H.; O'Sullivan, M.T.; Kougias, P.; Lin, P.H.; Bush, R.L.; Guinn, G.; Bechara, C.; Cagiannos, C.; Pisimisis, G.; Barshes, N.; Pillack, S.; Guillory, B.; Cikrit, D.; Lalka, S.G.; Lemmon, G.; Nachreiner, R.; Rusomaroff, M.; O'Brien, E.; Cullen, J.J.; Hoballah, J.; Sharp, W.J.; McCandless, J.L.; Beach, V.; Minion, D.; Schwarcz, T.H.; Kimbrough, J.; Ashe, L.; Rockich, A.; Warner-Carpenter, J.; Moursi, M.; Eidt, J.F.; Brock, S.; Bianchi, C.; Bishop, V.; Gordon, I.L.; Fujitani, R.; Kubaska, S.M.; Behdad, M.; Azadegan, R.; Ma Agas, C.; Zalecki, K.; Hoch, J.R.; Carr, S.C.; Acher, C.; Schwarze, M.; Tefera, G.; Mell, M.; Dunlap, B.; Rieder, J.; Stuart, J.M.; Weiman, D.S.; Abul-Khoudoud, O.; Garrett, H.E.; Walsh, S.M.; Wilson, K.L.; Seabrook, G.R.; Cambria, R.A.; Brown, K.R.; Lewis, B.D.; Framberg, S.; Kallio, C.; Barke, R.A.; Santilli, S.M.; d'Audiffret, A.C.; Oberle, N.; Proebstle, C.; Johnson, L.L.; Jacobowitz, G.R.; Cayne, N.; Rockman, C.; Adelman, M.; P.J. Gagne (Paul); Nalbandian, M.; Caropolo, L.J.; Pipinos, I.I.; Johanning, J.; Lynch, T.; DeSpiegelaere, H.; Purviance, G.; Zhou, W.; Dalman, R.; Lee, J.T.; Safadi, B.; Coogan, S.M.; Wren, S.M.; Bahmani, D.D.; Maples, D.; Thunen, S.; Golden, M.A.; Mitchell, M.E.; Fairman, R.; Reinhardt, S.; Wilson, M.A.; Tzeng, E.; Muluk, S.; Peterson, N.M.; Foster, M.; Edwards, J.; G. Moneta (Greg); Landry, G.; Taylor, L.; Yeager, R.; Cannady, E.; Treiman, G.; Hatton-Ward, S.; Salabsky, B.; Kansal, N.; Owens, E.; Estes, M.; Forbes, B.A.; Sobotta, C.; Rapp, J.H.; Reilly, L.M.; Perez, S.L.; Yan, K.; Sarkar, R.; Dwyer, S.S.; Perez, S.; Chong, K.; Kohler, T.R.; Hatsukami, T.S.; Glickerman, D.G.; Sobel, M.; Burdick, T.S.; Pedersen, K.; Cleary, P.; Back, M.; Bandyk, D.; Johnson, B.; Shames, M.; Reinhard, R.L.; Thomas, S.C.; Hunter, G.C.; Leon, L.R.; Westerband, A.; Guerra, R.J.; Riveros, M.; Mills, J.L.; Hughes, J.D.; Escalante, A.M.; Psalms, S.B.; Day, N.N.; Macsata, R.; Sidawy, A.; Weiswasser, J.; Arora, S.; Jasper, B.J.; A. Dardik; Gahtan, V.; B.E. Muhs (Bart); B.E. Sumpio (Bauer); R.J. Gusberg (Richard Jefferson); Spector, M.; Pollak, J.; Aruny, J.; Kelly, E.L.; Wong, J.; Vasilas, P.; Joncas, C.; Gelabert, H.A.; DeVirgillio, C.; Rigberg, D.A.; Cole, L.; Becquemin, J.-P.; Marzelle, J.; Becquemin, J.-P.; Sapoval, M.; Becquemin, J.-P.; Favre, J.-P.; Watelet, J.; Lermusiaux, P.; Sapoval, M.; Lepage, E.; Hemery, F.; Dolbeau, G.; Hawajry, N.; Cunin, P.; Harris, P.; L. Stockx (Luc); Chatellier, G.; Mialhe, C.; Fiessinger, J.-N.; Pagny, L.; Kobeiter, H.; Boissier, C.; Lacroix, P.; Ledru, F.; Pinot, J.-J.; Deux, J.-F.; Tzvetkov, B.; Duvaldestin, P.; Watelet, J.; Jourdain, C.; David, V.; Enouf, D.; Ady, N.; Krimi, A.; Boudjema, N.; Jousset, Y.; Enon, B.; Blin, V.; Picquet, J.; L'Hoste, P.; Thouveny, F.; Borie, H.; Kowarski, S.; Pernes, J.-M.; Auguste, M.; Becquemin, J.-P.; Desgranges, P.; Allaire, E.; Marzelle, J.; H. Kobeiter (Hicham); Meaulle, P.-Y.; Chaix, D.; Juliae, P.; Fabiani, J.N.; Chevalier, P.; Combes, M.; Seguin, A.; Belhomme, D.; M. Sapoval; Baque, J.; Pellerin, O.; Favre, J.P.; Barral, X.; Veyret, C.; Watelet, J.; Peillon, C.; Plissonier, D.; Thomas, P.; Clavier, E.; Lermusiaux, P.; Martinez, R.; Bleuet, F.; Dupreix, C.; Verhoye, J.P.; Langanay, T.; Heautot, J.F.; Koussa, M.; Haulon, S.; Halna, P.; Destrieux, L.; Lions, C.; Wiloteaux, S.; J.P. Beregi (Jean Paul); Bergeron, P.; Pinot, J.-J.; Patra, P.; Costargent, A.; Chaillou, P.; D'Alicourt, A.; Goueffic, Y.; Cheysson, E.; Parrot, A.; Garance, P.; Demon, A.; Tyazi, A.; Pillet, J.-C.; Lescalie, F.; Tilly, G.; Steinmetz, E.; Favier, C.; Brenot, R.; Krause, D.; Cercueil, J.P.; O. Vahdat (Olivier); Sauer, M.; Soula, P.; Querian, A.; Garcia, O.; Levade, M.; Colombier, D.; Cardon, J.-M.; Joyeux, A.; Borrelly, P.; Dogas, G.; Magnan, P.-É.; Branchereau, A.; Bartoli, J.-M.; Hassen-Khodja, R.; Batt, M.; Planchard, P.-F.; Bouillanne, P.-J.; Haudebourg, P.; Bayne, J.; Gouny, P.; Badra, A.; Braesco, J.; Nonent, M.; Lucas, A.; Cardon, A.; Kerdiles, Y.; Rolland, Y.; Kassab, M.; Brillu, C.; Goubault, F.; Tailboux, L.; Darrieux, H.; Briand, O.; Maillard, J.-C.; Varty, K.; Cousins, C.

    2017-01-01

    textabstractBackground: The erosion of the early mortality advantage of elective endovascular aneurysm repair (EVAR) compared with open repair of abdominal aortic aneurysm remains without a satisfactory explanation. Methods: An individual-patient data meta-analysis of four multicentre randomized tri

  20. Endovascular Repair of a Ruptured Descending Thoracic Aortic Aneurysm

    Science.gov (United States)

    DeFrain, Michael; Strickman, Neil E.; Ljubic, Branimir J.; Dougherty, Kathryn G.; Gregoric, Igor D.

    2006-01-01

    Endovascular aneurysm repair has considerable potential advantages over the surgical approach as a treatment for thoracic aortic rupture, in part because open surgical repair of ruptured thoracic aortic aneurysms is associated with high mortality and morbidity rates. We describe the successful endovascular deployment of stent-grafts to repair a contained rupture of a descending thoracic aortic aneurysm in an 86-year-old man whose comorbidities prohibited surgery. Two months after the procedure, magnetic resonance angiography showed a patent stent-graft, a patent left subclavian artery, and complete exclusion of the aneurysm. PMID:16878637

  1. Early outcomes and perioperative risk assessment in elective open thoracoabdominal aortic aneurysm repair: An analysis of national data over a five-year period.

    Science.gov (United States)

    Dayama, Anand; Sugano, Dordaneh; Reeves, James G; Rivera, Aksim; Tsilimparis, Nikolaos

    2016-02-01

    Open surgical repair of thoracoabdominal aortic aneurysms remains associated with significant morbidity and mortality. We sought to analyse multicentre national data on early outcomes of open surgical thoracoabdominal aortic aneurysm repair. Patients who underwent open repair of thoracoabdominal aortic aneurysm from 2005 to 2010 were identified from the National Surgical Quality Improvement Program database. The primary endpoint was mortality at 30 days. Patient demographics, clinical variables, and intraoperative parameters were analysed by univariate and multivariate logistic regression methods to identify risk factors for mortality. Of the 682 elective repairs, 30-day outcomes of elective repairs were: 10.0% mortality, 21.6% surgical complications, 42.2% pulmonary complications, 17.2% renal complications, 12.9% cardiovascular complications, 19.2% septic complications, and 6.6% wound complications. Multivariate logistic regression analysis showed that age, ASA-class IV, dependent functional status prior to surgery, and operation time are independent risk factors for mortality. Our study found a higher rate of mortality nationwide, as compared to several previous single center studies.

  2. Extra-anatomic endovascular repair of an abdominal aortic aneurysm with a horseshoe kidney supplied by the aneurysmal aorta.

    Science.gov (United States)

    Rey, Jorge; Golpanian, Samuel; Yang, Jane K; Moreno, Enrique; Velazquez, Omaida C; Goldstein, Lee J; Chahwala, Veer

    2015-07-01

    Abdominal aortic aneurysm complicated by a horseshoe kidney (HSK, fused kidney) represents a unique challenge for repair. Renal arteries arising from the aneurysmal aorta can further complicate intervention. Reports exist describing the repair of these complex anatomies using fenestrated endografts, hybrid open repairs (debranching), and open aneurysmorrhaphy with preservation of renal circulation. We describe an extra-anatomic, fully endovascular repair of an abdominal aortic aneurysm with a HSK partially supplied by a renal artery arising from the aneurysm. We successfully applied aortouni-iliac endografting, femorofemoral bypass, and retrograde renal artery perfusion via the contralateral femoral artery to exclude the abdominal aortic aneurysm and preserve circulation to the HSK.

  3. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  4. Long-term Computed Tomography Follow-up After Open Surgical Repair of Abdominal Aortic Aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mantoni, M.; Neergaard, K.; Christoffersen, J. K.; Lambine, T.L.; Baekgaard, N. [Gentofte Univ. Hospital (Denmark). Depts. of Radiology and Vascular Surgery

    2006-07-15

    Purpose: To describe the findings on computed tomography (CT) of the aortic sac (AS) in patients operated on for abdominal aortic aneurysm (AAA) with insertion of a coated Dacron prosthesis. Material and Methods: A prospective study of 36 consecutive patients operated on for AAA over 2 years and followed longitudinally with CT for up to 10 years. Results: All patients had a fluid-filled AS on CT 7-10 days postoperatively. At 6 months, the AS had decreased in most patients, mainly in the antero-posterior diameter, and in two had disappeared completely. In five patients with complications, the AS increased in size. The AS disappeared completely at 10 years' follow-up in 13 patients. When present, a retroperitoneal hematoma always disappeared after 6 months. Conclusion: These data indicate that the AS after graft implantation will diminish gradually but will persist for at least 6 months. Usually the transverse diameter is bigger than the antero-posterior diameter. If the AS enlarges and becomes rounded and distended with an inhomogeneous interior, it might be a sign of graft infection. In these cases an ultrasound-guided or CT-guided puncture is recommended.

  5. Comparison of clinical curative effect between open surgery and endovascular repair of abdominal aortic aneurysm in China

    Institute of Scientific and Technical Information of China (English)

    WANG Si-wen; LIN Ying; YAO Chen; LIN Pei-liang; WANG Shen-ming

    2012-01-01

    Objective To compare clinical curative effects of open surgery (OS) or endovascular repair (EVAR) for patients with abdominal aortic aneurysm (AAA) in China.Data sources We performed a comprehensive search of both English and Chinese literatures involving case studies on retrograde OS or EVAR of AAA in China from January 1976 to December 2010.Study selection According to the inclusion criteria,76 articles were finally analyzed to compare patient characteristics,clinical success,complications,and prognosis.Results We analyzed a total of 2862 patients with 1757 undergoing OS (OS group) and 1105 undergoing EVAR (EVAR group).There was no significant difference in the success rate of the procedures.Operative time,length of ICU stay,fasting time,duration of total postoperative stay,blood loss,and blood transfusion requirements during the procedure were significantly lower in the EVAR group.A 30-day follow up revealed more cardiac,renal,pulmonary,and visceral complications in the OS group (P<0.01).Low-limb ischemia,however,was more common in the EVAR group (P<0.05).The 30-day mortality rate,including aorta-related and non-aorta related mortality,was significantly lower in the EVAR group (P<0.01).In the follow-up period,there were more patients with occlusions of artificial vessel and late endoleak in the EVAR group (P<0.01).The overall late mortality rate was higher in the OS group (P <0.01),especially non-aorta-related late mortality and mortality during the fourth to the sixth year (P<0.01).Conclusions EVAR was safer and less invasive for AAA patients.Patients suffered fewer complications and recovered sooner.However,complications such as artificial vessel occlusion,low-limb ischemia,and endoleak were common in EVAR.Clinicians should carry out further research to solve these complications and improve the efficacy of EVAR.

  6. Early inflammatory response following elective abdominal aortic aneurysm repair: A comparison between endovascular procedure and conventional, open surgery

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2011-01-01

    Full Text Available Background/Aim. Abdominal aorta aneurysm (AAA represents a pathological enlargment of infrarenal portion of aorta for over 50% of its lumen. The only treatment of AAA is a surgical reconstruction of the affected segment. Until the late XX century, surgical reconstruction implied explicit, open repair (OR of AAA, which was accompanied by a significant morbidity and mortality of the treated patients. Development of endovascular repair of (EVAR AAA, especially in the last decade, offered another possibility of surgical reconstruction of AAA. The preliminary results of world studies show that complications of such a procedure, as well as morbidity and mortality of patients, are significantly lower than with OR of AAA. The aim of this paper was to present results of comparative clinical prospective study of early inflammatory response after reconstruction of AAA between endovascular and open, conventional surgical technique. Methods. A comparative clinical prospective study included 39 patients, electively operated on for AAA within the period of December 2008 - February 2010, divided into two groups. The group I counted 21 (54% of the patients, 58-87 years old (mean 74.3 years, who had been submited to EVAR by the use of excluder stent graft. The group II consisted of 18 (46% of the patients, 49-82 (mean 66.8 years, operated on using OR technique. All of the treated patients in both groups had AAA larager than 50 mm. The study did not include patients who have been treated as urgent cases, due to the rupture or with simptomatic AAA. Clinical, biochemical and inflamatory parameters in early postoperative period were analyzed, in direct postoperative course (number of leucocytes, thrombocytes, serum circulating levels of cytokine - interleukine (IL-2, IL-4, IL-6 and IL-10. Parameters were monitored on the zero, first, second, third and seventh postoperative days. The study was approved by the Ethics Commitee of the Military Medical Academy. Results

  7. Endovascular repair of ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Šarac Momir

    2014-01-01

    Full Text Available Introduction. Rupture of an abdominal aortic aneurysm (AAA is a potentially lethal state. Only half of patients with ruptured AAA reach the hospital alive. The alternative for open reconstruction of this condition is endovascular repair (EVAR. We presented a successful endovascular reapir of ruptured AAA in a patient with a number of comorbidities. Case report. A 60-year-old man was admitted to our institution due to diffuse abdominal pain with flatulence and belching. Initial abdominal ultrasonography showed an AAA that was confirmed on multislice computed tomography scan angiography which revealed a large retroperitoneal haematoma. Because of patient’s comorbidites (previous surgery of laryngeal carcinoma and one-third laryngeal stenosis, arterial hypertension and cardiomyopathy with left ventricle ejection fraction of 30%, stenosis of the right internal carotid artery of 80% it was decided that endovascular repair of ruptured AAA in local anaesthesia and analgosedation would be treatment of choice. Endovascular grafting was achieved with aorto-bi-iliac bifurcated excluder endoprosthesis with complete exclusion of the aneurysmal sac, without further enlargment of haemathoma and no contrast leakage. The postoperative course of the patient was eventless, without complications. On recall examination 3 months after, the state of the patient was well. Conclusion. The alternative for open reconstruction of ruptured AAA in haemodynamically stable patients with suitable anatomy and comorbidities could be emergency EVAR in local anesthesia. This technique could provide greater chances for survival with lower intraoperative and postoperative morbidity and mortality, as shown in the presented patient.

  8. Six years' experience with prostaglandin I2 infusion in elective open repair of abdominal aortic aneurysm: a parallel group observational study in a tertiary referral vascular center.

    LENUS (Irish Health Repository)

    Beirne, Chris

    2008-11-01

    The prostaglandin I(2) (PGI(2)) analogue iloprost, a potent vasodilator and inhibitor of platelet activation, has traditionally been utilized in pulmonary hypertension and off-label use for revascularization of chronic critical lower limb ischemia. This study was designed to assess the effect of 72 hr iloprost infusion on systemic ischemia post-open elective abdominal aortic aneurysm (EAAA) surgery. Between January 2000 and 2007, 104 patients undergoing open EAAA were identified: 36 had juxtarenal, 15 had suprarenal, and 53 had infrarenal aneurysms, with a mean maximal diameter of 6.9 cm. The male-to-female ratio was 2.5:1, with a mean age of 71.9 years. No statistically significant difference was seen between the study groups with regard to age, sex, risk factors, American Society of Anesthesiologists (ASA) grade, or diameter of aneurysm repaired. All emergency, urgent, and endovascular procedures for aneurysms were excluded. Fifty-seven patients received iloprost infusion for 72 hr in the immediate postoperative period compared with 47 patients who did not. Patients were monitored for signs of pulmonary, renal, cardiac, systemic ischemia, and postoperative intensive care unit (ICU) morbidity. Statistically significantly increased ventilation rates (p=0.0048), pulmonary complication rates (p=0.0019), and myocardial ischemia (p=0.0446) were noted in those patients not receiving iloprost. These patients also had significantly higher renal indices including estimate glomerular filtration rate changes (p=0.041) and postoperative urea level rises (p=0.0286). Peripheral limb trashing was noted in five patients (11.6%) in the non-iloprost group compared with no patients who received iloprost. Increased rates of transfusion requirements and bowel complications were noted in those who did not receive iloprost, with their ICU stay greater than twice that of iloprost patients. All-cause morbidity affected 67% of patients not receiving iloprost compared to 40% who did

  9. Why routine intensive care unit admission after elective open infrarenal Abdominal Aortic Aneurysm repair is no longer an evidence based practice.

    LENUS (Irish Health Repository)

    Ryan, David

    2012-01-31

    BACKGROUND: Elective open infrarenal Abdominal Aortic Aneurysm (AAA) repair is major surgery performed on high-risk patients. Routine ICU admission postoperatively is the current accepted standard of care. Few of these patients actually require a level of care that cannot be provided just as effectively in a surgical high dependency unit (HDU). Our aim was to determine, \\'can high risk patients that will require ICU admission postoperatively be reliably identified preoperatively?\\'. METHODS: A retrospective analysis of all elective open infrarenal AAA repairs in our institution over a 3-year period was performed. The Estimation of Physiological Ability and Surgical Stress (E-PASS) model was used as our risk stratification tool for predicting post-operative morbidity. Renal function was also considered as a predictor of outcome, independent of the E-PASS. RESULTS: 80% (n = 16) were admitted to ICU. Only 30% (n = 6) of the total study population necessitated intensive care. There were 9 complications in 7 patients in our study. The E-PASS comprehensive risk score (CRS)\\/Surgical stress score (SSS) were found to be significantly associated with the presence of a complication (p = 0.009)\\/(p = 0.032) respectively. Serum creatinine (p = 0.013) was similarly significantly associated with the presence of a complication. CONCLUSIONS: The E-PASS model possessing increasing external validity is an effective risk stratification tool in safely deciding the appropriate level of post-operative care for elective infrarenal AAA repairs.

  10. A comparative study on the medium-long term results of endovascular repair and open surgical repair in the management of ruptured abdominal aortic aneurysms

    Institute of Scientific and Technical Information of China (English)

    HAN Yan-shuo; ZHANG Jian; XIA Qian; LIU Zhi-min; ZHANG Xiao-yu; WU Xiao-yu; LUN Yu

    2013-01-01

    Background Although it is generally acknowledged that patients with ruptured abdominal aortic aneurysm (rAAA)obtain the greatest benefit from endovascular repair (EVAR),convincing evidence on the medium-long term effect is lacking.The aim of this study was to compare and summarize published results of rAAA that underwent EVAR with open surgical repair (OSR).Methods A search of publicly published literature was performed.Based on an inclusion and exclusion criteria,a systematic meta-analysis was undertaken to compare patient characteristics,complications,short term mortality and medium-long term outcomes.A random-effects model was used to pool the data and calculate pooled odds ratios and weighted mean differences.A quantitative method was used to analyze the differences between these two methods.Results A search of the published literature showed that fourteen English language papers comprising totally 1213 patients with rAAA (435 EVAR and 778 OSR) would be suitable for this study.Furthermore,13 Chinese studies were included,including 267 patients with rAAA totally,among which 238 patients received operation.The endovascular method was associated with more respiratory diseases before treatment (OR=1.81,P=0.01),while there are more patients with hemodynamic instability before treatment in OSR group (OR=1.53,P=0.031).Mean blood transfusion was 1328 ml for EVAR and 2809 ml for OSR (weighted mean difference (WMD) 1500 ml,P=0.014).The endovascular method was associated with a shorter stay in intensive care (WMD 2.34 days,P <0.001) and a shorter total postoperative stay (WMD 6.27 days,P <0.001).The pooled post-operative complication rate of respiratory system and visceral ischemia seldom occurred in the EVAR group (OR=0.48,P <0.001 and OR=0.28,P=0.043,respectively).The pooled 30-day mortality was 25.7% for EVAR and 39.6% for OSR,and the odds ratio was 0.53 (95% confidence interval (CI) 0.41-0.70,P <0.001).There was not,however,any significant reduction in

  11. Fenestrated and branched endovascular techniques for thoraco-abdominal aneurysm repair

    NARCIS (Netherlands)

    Verhoeven, ELG; Zeebregts, CJ; Kapma, MR; Tielliu, IFJ; Prins, TR; Van Den Dungen, JJAM

    2005-01-01

    Since 1991, endovascular aortic aneurysm repair (EVAR) has been established as an alternative for open surgical repair of aortic aneurysms. one of the main limitations for EVAR is the need for a sufficient scaling zone below or above vital aortic side branches. Recently, efforts have been made to ov

  12. New insights in (acute) endovascular abdominal aneurysm repair : when fenestrated devices fall short

    NARCIS (Netherlands)

    Pol, R. A.; Tielliu, I. F. J.; Zeebregts, C. J.

    2013-01-01

    The suitability for endovascular aneurysm repair (EVAR) is determined primarily by abdominal aortic aneurysm (AAA) anatomy. For patients unsuitable for standard EVAR, due to proximal neck anatomy, fenestrated aortic stent-grafting (FEVAR) is a viable alternative to open repair surgery. Initially FEV

  13. A two-year follow-up for Chinese patients with abdominal aortic aneurysm undergoing open/endovascular repair

    Institute of Scientific and Technical Information of China (English)

    Sun Tao; Zhang Hongju; Cheng Yutong; Wang Su; Tao Ying; Zhang Donghua; Huang Ji

    2014-01-01

    Background A number of studies have demonstrated the rates of overall and aneurysm-related mortality and morbidity in Western populations.The cardiovascular risk factors influencing postoperative outcome have been also reported.Until recently,little has been known about the prognosis in this patient cohort in the Chinese population.We evaluated the independent predictors of mortality and morbidity in abdominal aortic aneurysm (AAA) patients undergoing elective surgical treatment and emphasized whether the coronary artery revascularization could have any effect on the overall mortality and morbidity in patients following the current guideline recommendation.Methods A total of 386 patients (174 women) undergoing surgery in Beijing Anzhen Hospital from January 2008 to June 2010 were enrolled (mean age (70.6±10.5) years).Kaplan-Meier curves were constructed to compare the mortality and morbidity of AAA patients with coronary artery revascularization and those without.A Cox proportional hazards model was constructed to identify clinical factors associated with two-year outcomes.The primary outcomes were death from any cause,the pre-specified morbidity was re-hospitalization for pulmonary conditions,congestive heart failure,angina,ischemic/hemorrhagic stroke.Results During the two-year follow-up,34 patients died and 65 experienced re-hospitalization with pulmonary conditions,congestive heart failure,angina,or ischemic/hemorrhagic stroke.Kaplan-Meier survival analysis showed that the AAA patients with cardiac revascularization had no higher incidence of overall mortality and major morbidity than those without (log-rank test P=0.35 and P=0.40,respectively).Cox proportional hazards regression analysis showed that level of low-density lipoprotein (HR,4.06; 95% CI:1.19-18.7,P=0.027) and AAA size (HR,2.18; 95% CI:1.28-11.65,P=0.036) were independently associated with the incidence of overall mortality.Long-term use of angiotensin converting enzyme inhibitors

  14. Endovascular abdominal aortic aneurysm repair in the geriatric population

    Institute of Scientific and Technical Information of China (English)

    Athanasios Saratzis; Saif Mohamed

    2012-01-01

    Abdominal aortic aneurysm (AAA) is a relatively common pathology among the elderly. More people above the age of 80 will have to undergo treatment of an AAA in the future. This review aims to summarize the literature focusing on endovascular repair of AAA in the geriatric population. A systematic review of the literature was performed, including results from endovascular abdominal aortic aneurysm repair (EVAR) registries and studies comparing open repair and EVAR in those above the age of 80. A total of 15 studies were identified. EVAR in this population is efficient with a success rate exceeding 90% in all cases, and safe, with early mortality and morbidity being superior among patients undergoing EVAR against open repair. Late survival can be as high as 95% after 5 years. Aneurysm-related death over long-term follow-up was low after EVAR, ranging from 0 to 3.4%. Endovascular repair can be offered safely in the geriatric population and seems to compare favourably with open repair in all studies in the literature to date.

  15. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  16. Novel Visceral-Anastomosis-First Approach in Open Repair of a Ruptured Type 2 Thoracoabdominal Aortic Aneurysm: Causes behind a Mortal Outcome

    Directory of Open Access Journals (Sweden)

    Einar Dregelid

    2013-01-01

    Full Text Available Case reports to analyze causes and possible prevention of complications in a new setting are important. We present an open repair of a ruptured type 2 thoracoabdominal aortic aneurysm in a 78-year-old man. Lower-body perfusion through a temporary extracorporeal axillobifemoral arterial prosthesis shunt was combined with the use of a branch to the permanent aortic prosthesis to enable rapid visceral revascularization using a visceral-anastomosis-first approach. The patient died due to transfusion-induced capillary leak syndrome and left colon necrosis; the latter was probably caused by a combination of back-bleeding from lumbar arteries causing a steal effect, an accidental shunt obstruction, and hemodynamic instability towards the end of the operation. The visceral-anastomosis-first approach did not contribute to the complications. This approach reduces the time when visceral organs are perfused only via collateral arteries to the time needed for suturing the visceral anastomoses. This may be important when collateral perfusion is marginal.

  17. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    Goncalves, Frederico Bastos; Verhagen, Hence J. M.; Chinsakchai, Khamin; van Keulen, Jasper W.; Voute, Michiel T.; Zandvoort, Herman J.; Moll, Frans L.; van Herwaarden, Joost A.

    2012-01-01

    Objective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The Netherlands from

  18. Current status of endovascular aneurysm repair: 20 years of learning.

    Science.gov (United States)

    Arko, Frank R; Murphy, Erin H; Boyes, Christopher; Nussbaum, Tzvi; Lalka, Stephen G; Holleman, Jeremiah; Roush, Timothy S

    2012-09-01

    Parodi first introduced endovascular aneurysm repair (EVAR) in 1991 and since that time it has been shown to have a lower 30-day morbididty and mortality compared to open surgery. Anatomic constraints governed by the need for adequate access vessels, and sufficient proximal and distal landing zones, as well as the need for long-term surveillance, have been the main limitations of this technology. Anatomic factors were initially estimated to exclude 40% of patients with abdominal aortic aneurysm (AAA). The rapid extension of EVAR technology has been complimented by improved access to both high-quality imaging modalities and a variety of endografts. These developments have led EVAR to become a more practical alternative for patients with ruptured AAA. Early data in this setting is encouraging with even more profound reductions in morbidity and mortality than seen in the elective repair.

  19. Endovascular repair of a paraanastomotic aneurysm with inverted limb infrarenal bifurcated graft.

    Science.gov (United States)

    Stringari, Carlo; Perkmann, Reinhold; Zaraca, Francesco

    2014-02-01

    A typical complication after conventional aortic prosthetic reconstruction is paraanastomotic aneurysm formation. Endovascular exclusion of paraanastomotic aneurysms has been shown to be a viable alternative to open surgical repair and to greatly reduce morbidity and mortality rates. We present a case report of asymptomatic proximal anastomotic pseudoaneurysm, measuring 4.5 cm in diameter, that was successfully treated by endovascular repair with a custom-made inverted limb infrarenal bifurcated graft.

  20. Custom Fenestration Templates for Endovascular Repair of Juxtarenal Aortic Aneurysms

    Science.gov (United States)

    Leotta, Daniel F.; Starnes, Benjamin W.

    2015-01-01

    Physician-modified endovascular grafts, with fenestrations added to accommodate major branch vessels, provide a means for endovascular treatment of abdominal aortic aneurysms that are adjacent to the renal arteries. Manual measurements of vessel origin locations from CT images, however, take time and can lead to errors in the positions of the fenestrations. To make the fenestration process faster and more accurate, we have developed a procedure to create custom templates that serve as patient-specific guides for graft fenestration. We use a 3D printer to create a clear rigid sleeve that replicates the patient’s aorta and includes holes placed precisely at the locations of the branch vessels. The sleeve is slipped over the graft, the locations of the openings are marked with a pen, and the fenestrations are created after removing the sleeve. Custom fenestration templates can potentially save procedural costs and make minimally-invasive aortic aneurysm repair available to more patients. PMID:25864045

  1. Endovascular Aneurysm Repair in HIV Patients with Ruptured Abdominal Aneurysm and Low CD4

    Directory of Open Access Journals (Sweden)

    Saranat Orrapin

    2016-01-01

    Full Text Available We report two HIV infected patients with ruptured abdominal aneurysm by using endovascular aneurysm repair (EVAR technique. A 59-year-old Thai man had a ruptured abdominal aortic aneurysm and a 57-year-old man had a ruptured iliac artery aneurysm. Both patients had a CD4 level below 200 μ/L indicating a low immune status at admission. They were treated by EVAR. Neither patient had any complications in 3 months postoperatively. EVAR may have a role in HIV patients with ruptured abdominal aneurysm together with very low immunity.

  2. MRI-based Assessment of Endovascular Abdominal Aortic Aneurysm Repair

    NARCIS (Netherlands)

    Laan, M.J. van der

    2007-01-01

    Imaging techniques play a key role in the Endovascular Abdominal Aortic Aneurysm Repair (EVAR) follow-up. The most important parameters monitored after EVAR are the aneurysm size and the presence of endoleaks. Currently, computed tomographic angiography (CTA) is the most commonly used imaging modali

  3. Application of occluders in endovascular repair of aortic aneurysms

    Institute of Scientific and Technical Information of China (English)

    SHI Zhen-yu; FU Wei-guo; WANG Yu-qi; GUO Da-qiao; CHEN Bin; JIANG Jun-hao; XU Xin; YANG Jue; ZHU Ting

    2007-01-01

    @@ Since Parodi et al1 reported the first successful case of endovascular treatment for abdominal aortic aneurysm (AAA) in 1991, the endovascular repair has become an important option for the surgical treatment of aortic aneurysms.2-4 The occluder is a newly-developed device introduced intraluminally to block the blood flow in certain arteries.

  4. Device-specific outcomes after endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    F.B. Gonçalves (Frederico Bastos); E.V. Rouwet (Ellen); R. Metz (Roderik); J.M. Hendriks (Joke); M.P.F.V. Peeters; B.E. Muhs (Bart); H.J.M. Verhagen (Hence)

    2010-01-01

    textabstractOver the last decade, endovascular aneurysm repair (EVAR) has been used extensively for the elective treatment of infra-renal abdominal aneurysms. However, it remains unclear how specific devices perform and how they compare to others. We provide an overview of currently used endografts,

  5. Transient cortical blindness after thoracic endovascular aneurysm repair.

    Science.gov (United States)

    Vallabhaneni, Raghuveer; Jim, Jeffrey; Derdeyn, Colin P; Sanchez, Luis A

    2011-05-01

    We report a patient who presented with transient cortical blindness 12 hours after completion of a thoracic endovascular aneurysm repair. Computed tomography of the brain demonstrated no acute findings. The patient's symptoms resolved spontaneously after 72 hours. To our knowledge, this is the first report of transient cortical blindness after endovascular aortic aneurysm repair. This is an uncommon diagnosis that is important to recognize in a modern vascular surgery practice.

  6. Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Wever, JJ; Blankensteijn, JD; Mali, WPTM; Eikelboom, BC

    2000-01-01

    Background: follow-up after endovascular abdominal aortic aneurysm repair (EAR) generally consists of serial diameter measurements. A size change after EAR, however, is the consequence of alterations of the excluded aneurysm sac volume. Objective: to assess the agreement between diameter measurement

  7. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    F.M.V. Bastos Gonçalves (Frederico); H.J.M. Verhagen (Hence); K. Chinsakchai (Khamin); J.W. van Keulen (Jasper); M.T. Voûte (Michiel); H.J.A. Zandvoort (Herman); F.L. Moll (Frans); J.A. van Herwaarden (Joost)

    2012-01-01

    textabstractObjective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The Neth

  8. Hérnias incisionais no pós-operatório de correção de aneurisma de aorta abdominal Postoperative incisional hernias after open abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Fábio Hüsemann Menezes

    2012-09-01

    Full Text Available CONTEXTO: A incidência de hérnia incisional no pós-operatório da correção aberta de aneurisma de aorta abdominal é alta, variando de 10 a 37% e mais de três vezes mais comum do que em pacientes submetidos à correção para doença obstrutiva aorto-ilíaca. OBJETIVO: Apresentar a incidência de hérnia incisional em um grupo de pacientes acompanhados no pós-operatório da correção aberta de aneurisma de aorta abdominal. MÉTODOS: Série de casos em uma população de 144 pacientes operados por aneurisma de aorta abdominal, entre junho de 1989 e junho de 2010, e que estão em acompanhamento regular no Ambulatório de Moléstias Vasculares. RESULTADOS: O seguimento médio dos pacientes foi de 63 meses (1 a 238. A idade média foi de 67 anos (45 a 91 e o tamanho médio dos aneurismas foi de 6,54 cm. Foram realizadas 130 laparotomias medianas xifo-púbicas e 13 acessos extraperitoniais pelo flanco esquerdo. Nestes pacientes, a incidência de hérnia incisional foi de 18,5 e 7,7%, respectivamente, para incisões na linha média ou no flanco (p=0,315. Um paciente apresentou abaulamento da musculatura oblíqua por denervação. Foi realizada uma laparotomia transversa, que não apresentou hérnia no pós-operatório tardio. CONCLUSÕES: A incidência de hérnia incisional na cirurgia aberta para correção de aneurisma de aorta abdominal é alta, ocorre com maior frequência em incisões da linha média e tem relação direta com a técnica empregada para o fechamento da aponeurose, exigindo do cirurgião atenção especial para este tempo cirúrgico para evitar a causa mais comum de reoperação em tal grupo de pacientes.BACKGROUND: The incidence of incisional hernia in the post operatory of patients submitted to open abdominal aortic aneurysm repair is high, ranging from 10 to 37%, and is more than three times higher than the incidence of hernias in patients operated for aorto-iliac occlusion. OBJECTIVE: To evaluate the incidence of

  9. Open Surgical Repair After Endovascular Treatment with Endologix Stent Graft: A Case Report

    Directory of Open Access Journals (Sweden)

    Ižsa Coskun

    2016-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysm repair is increasingly being used today. We report a 72-year-old male patient who underwent open surgical repair due to separation of IntuTrak Powerlink XL (Endologix endovascular stent graft four months after endovascular intervention for abdominal aortic aneurysm with 9.5 cm diameter.

  10. Thrombus Volume Change Visualization after Endovascular Abdominal Aortic Aneurysm Repair

    Science.gov (United States)

    Maiora, Josu; García, Guillermo; Macía, Iván; Legarreta, Jon Haitz; Boto, Fernando; Paloc, Céline; Graña, Manuel; Abuín, Javier Sanchez

    A surgical technique currently used in the treatment of Abdominal Aortic Aneurysms (AAA) is the Endovascular Aneurysm Repair (EVAR). This minimally invasive procedure involves inserting a prosthesis in the aortic vessel that excludes the aneurysm from the bloodstream. The stent, once in place acts as a false lumen for the blood current to travel down, and not into the surrounding aneurysm sac. This procedure, therefore, immediately takes the pressure off the aneurysm, which thromboses itself after some time. Nevertheless, in a long term perspective, different complications such as prosthesis displacement or bloodstream leaks into or from the aneurysmatic bulge (endoleaks) could appear causing a pressure elevation and, as a result, increasing the danger of rupture. The purpose of this work is to explore the application of image registration techniques to the visual detection of changes in the thrombus in order to assess the evolution of the aneurysm. Prior to registration, both the lumen and the thrombus are segmented

  11. Implementation of the Continuous AutoTransfusion System (C.A.T.S) in open abdominal aortic aneurysm repair: an observational comparative cohort study.

    LENUS (Irish Health Repository)

    Tawfick, Wael A

    2008-01-01

    The use of the Continuous AutoTransfusion System (C.A.T.S; Fresenius Hemotechnology, Bad Homburg v.d.H., Germany), which conserves allogenic blood, is reported in 187 patients having abdominal aortic aneurysm repair during a 9-year period. Patients were allocated to C.A.T.S if a Haemovigilance technician was available. A mean of 685 mL of retrieved blood was reinfused in 101 patients receiving C.A.T.S; 61% required 2 U or less. All control patients required 3 U or more of allogenic blood. Allogenic transfusion in C.A.T.S patients decreased significantly (P < .0001). Mean intensive care unit stay was significantly reduced in C.A.T.S patients (P = .042). Mean postoperative hospital stay was 18 days for C.A.T.S group and 25 days in control patients (P = .014). The respective 30-day mortality was 12% versus 19% (P = .199). The C.A.T.S markedly reduced the amount of blood transfused, was associated with reduced intensive care unit and postoperative hospital stay, and was cost-effective.

  12. A case of acute ischemic colitis after endovascular abdominal aortic aneurysm repair

    Institute of Scientific and Technical Information of China (English)

    Grigorios Voulalas; Chrisostomos Maltezos

    2016-01-01

    Colonic ischemia is a recognized complication of either open or endovascular abdominal aortic aneurysm repair. The clinical difficulty in establishing the diagnosis, the severity of this complication and the patient's poor physiological status may lead to a fatal outcome. We presented a case of ischemic colitis in a patient with patent hypogastric arteries that occurred after an endovascular abdominal aortic aneurysm repair as well as a review of the available literature. The patient's preoperative, intraoperative and postoperative data were recorded. A thorough search through the Google data and Medline to review similar cases or any analyses that referred to ischemic colitis after endovascular abdominal aneurysm repair was conducted. A 76-year-old male was admitted to our department for an elective endovascular repair of an 8 cm in diameter abdominal aortic aneurysm. A Zenith bifurcation graft was implanted. The whole procedure was uneventful and the final angiogram showed an accurate deployment of the endograft without endoleaks and patency of both hypogastric arteries. During the 1st postoperative day, the patient developed symptoms of acute abdomen in combination with metabolic acidosis and oliguria. He underwent an exploratory laparotomy, which revealed necrosis of the sig-moid. A Hartmann's procedure was performed;the patient was transferred to the intensive care unit where he deceased after 24 h. Postoperative ischemic colitis has been described after open abdominal aneurysm repair. The description of this complication has been reported since the early phase of endovascular abdominal aneurysm repair development with a current incidence of 1.5%–3.0%. Possible mechanisms that may contribute to ischemic colitis in spite of the presence of patent hypogastric arteries include athe-roembolization, shock, vasopressive drugs and inferior mesenteric artery occlusion.

  13. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  14. MRI follow-up of abdominal aortic aneurysms after endovascular repair

    NARCIS (Netherlands)

    Cornelissen, S.A.P.

    2012-01-01

    Aneurysm size changes form the basis of the follow-up after endovascular abdominal aortic aneurysm repair, because aneurysm growth increases rupture risk. Aneurysm growth can be caused by endoleak (leakage of blood in the aneurysm sac). Therefore, accurate endoleak detection is important in growing

  15. Outcomes of Endovascular Repair of Ruptured Descending Thoracic Aortic Aneurysms

    NARCIS (Netherlands)

    Jonker, Frederik H. W.; Verhagen, Hence J. M.; Lin, Peter H.; Heijmen, Robin H.; Trimarchi, Santi; Lee, W. Anthony; Moll, Frans L.; Athamneh, Husam; Muhs, Bart E.

    2010-01-01

    Background-Thoracic endovascular aortic repair offers a less invasive approach for the treatment of ruptured descending thoracic aortic aneurysms (rDTAA). Due to the low incidence of this life-threatening condition, little is known about the outcomes of endovascular repair of rDTAA and the factors t

  16. Outcomes of endovascular repair of ruptured descending thoracic aortic aneurysms

    NARCIS (Netherlands)

    F.H.W. Jonker; H.J.M. Verhagen (Hence); P.H. Lin (Peter); R.H. Heijmen (Robin); S. Trimarchi (Santi); W.A. Lee (Anthony); F.L. Moll (Frans); H. Athamneh (Husam); B.E. Muhs (Bart)

    2010-01-01

    textabstractBackground-: Thoracic endovascular aortic repair offers a less invasive approach for the treatment of ruptured descending thoracic aortic aneurysms (rDTAA). Due to the low incidence of this life-threatening condition, little is known about the outcomes of endovascular repair of rDTAA and

  17. Endovascular repair:alternative treatment of ruptured abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    GUO Wei; ZHANG Hong-peng; LIU Xiao-ping; YIN Tai; JIA Xin; LIANG Fa-qi; ZHANG Guo-hua

    2009-01-01

    Background As an alternative to open aneurysm repair,endovascular aortic repair(EVAR)has been applied to ruptured abdominal aortic aneurysm(rAAA).The aim of this study was to evaluate the immediate and long-term outcomes of EVAR for rAAA.Methods From July 1997 to September 2007,20 men and six women with rAAA(median age,68 years)were treated with EVAR.Most patients with suspected rAAA underwent emergency computed tomographic angiography(CTA).The procedure was performed under general or local anesthesia.Endovascular clamping was attempted in hemodynamically unstable patients.Bifurcated endografts and aorto-uni-iliac(AUI)endografts with crossover bypass were used.Patients had CT scan prior to discharge,3,6,12 months after discharge,and annually thereafter.Results Time between diagnosis and EVAR ranged from 1 hour to 5 days.EVAR was performed under general anesthesia in 21 patients,and under local anesthesia in five patients.Endovascular aortic clamping was performed in four patients.There was no conversion to open surgery during EVAR.Stent-graft insertion was successful in all patients.One patient died during EVAR from acute myocardial infarction.Ten patients had systolic blood pressure<80 mm Hg.Eleven patients received a blood transfusion.Mean aneurysm size was(47c12)mm.Mean ICU stay was(8±3)days,mean hospital stay(18±6)days,and mean procedure time(120±32)minutes.The 30-day mortality was 23%(6/26patients),and major morbidity 35%(9/26 patients).Early endoleak occurred in 8/26 patients(31%).The mean follow-up was(18±7)months.No patient demonstrated migration of the stent-graft.Conclusions EVAR is a safe and effective option for treatment of acute rAAA,independent of the patient's general condition.Immediate and mid-term outcomes are favorable,but long-term outcome is unknown.Multi-center studies are necessary to establish the role of EVAR for rAAA.

  18. Open aortic surgery after thoracic endovascular aortic repair.

    Science.gov (United States)

    Coselli, Joseph S; Spiliotopoulos, Konstantinos; Preventza, Ourania; de la Cruz, Kim I; Amarasekara, Hiruni; Green, Susan Y

    2016-08-01

    In the last decade, thoracic endovascular aortic aneurysm repair (TEVAR) has emerged as an appealing alternative to the traditional open aortic aneurysm repair. This is largely due to generally improved early outcomes associated with TEVAR, including lower perioperative mortality and morbidity. However, it is relatively common for patients who undergo TEVAR to need a secondary intervention. In select circumstances, these secondary interventions are performed as an open procedure. Although it is difficult to assess the rate of open repairs after TEVAR, the rates in large series of TEVAR cases (>300) have ranged from 0.4 to 7.9 %. Major complications of TEVAR that typically necessitates open distal aortic repair (i.e., repair of the descending thoracic or thoracoabdominal aorta) include endoleak (especially type I), aortic fistula, endograft infection, device collapse or migration, and continued expansion of the aneurysm sac. Conversion to open repair of the distal aorta may be either elective (as for many endoleaks) or emergent (as for rupture, retrograde complicated dissection, malperfusion, and endograft infection). In addition, in select patients (e.g., those with a chronic aortic dissection), unrepaired sections of the aorta may progressively dilate, resulting in the need for multiple distal aortic repairs. Open repairs after TEVAR can be broadly classified as full extraction, partial extraction, or full salvage of the stent-graft. Although full and partial stent-graft extraction imply failure of TEVAR, such failure is generally absent in cases where the stent-graft can be fully salvaged. We review the literature regarding open repair after TEVAR and highlight operative strategies.

  19. Near-infrared spectroscopy assessed cerebral oxygenation during open abdominal aortic aneurysm repair: relation to end-tidal CO2 tension.

    Science.gov (United States)

    Sørensen, H; Nielsen, H B; Secher, N H

    2016-08-01

    During open abdominal aortic aneurism (AAA) repair cerebral blood flow is challenged. Clamping of the aorta may lead to unintended hyperventilation as metabolism is reduced by perfusion of a smaller part of the body and reperfusion of the aorta releases vasodilatory substances including CO2. We intend to adjust ventilation according end-tidal CO2 tension (EtCO2) and here evaluated to what extent that strategy maintains frontal lobe oxygenation (ScO2) as determined by near infrared spectroscopy. For 44 patients [5 women, aged 70 (48-83) years] ScO2, mean arterial pressure (MAP), EtCO2, and ventilation were obtained retrospectively from the anesthetic charts. By clamping the aorta, ScO2 and EtCO2 were kept stable by reducing ventilation (median, -0.8 l min(-1); interquartile range, -1.1 to -0.4; P body is reperfused.

  20. Local anesthesia for endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Verhoeven, ELG; Cina, CS; Tielliu, IFJ; Zeebregts, CJ; Prins, TR; Eindhoven, GB; Span, MM; Kapma, MR; van den Dungen, JJAM

    2005-01-01

    Objectives: This study reports the results of a prospective continuous cohort of patients treated for endovascular aneurysm repair (EVAR) with a unified anesthetic strategy based on the use of local anesthesia (LA) in all patients, while reserving regional (RA) or general anesthesia (GA) only for th

  1. Mesenteric ischemia after abdominal aortic aneurysm repair : a systemic review

    NARCIS (Netherlands)

    Bruggink, J. L. M.; Tielliu, I. F. J.; Zeebregts, C. J.; Pol, R. A.

    2014-01-01

    Mesenteric ischemia after abdominal aneurysm repair is a devastating complication with mortality rates up to 70%. Incidence however is relatively low. The aim of this review was to provide an overview on current insights, diagnostic modalities and on mesenteric ischemia after abdominal aortic aneury

  2. Repair of abdominal aortic aneurysms with aorto-uni-iliac stentgraft and femoro-femoral bypass.

    Science.gov (United States)

    Smit, J G M; van Marle, J

    2012-03-29

    Endovascular repair (EVAR) is accepted as effective treatment for abdominal aortic aneurysms (AAAs) and has become the standard of care in many instances. The standard bifurcated stentgraft (BFG) is often not possible in patients with unfavourable aneurysm morphology. The aorto-uni-iliac (AUI) graft configuration with femoro-femoral bypass (FFBP) is a promising alternative which may extend the scope of EVAR for AAAs. The aim of this study was to evaluate the feasibility, efficacy and durability of AUI with FFBP. Design. The results of a single institution and a single surgeon were prospectively collected from January 2002 to August 2010. All patients were followed up at 1, 3, 6 and 12 months and then annually. Results. There were 33 patients (27 males) with a mean age of 71.7 years (range 46 - 84). Open surgery posed an unacceptably high risk to all patients owing to advanced age and/or American Society of Anesthesiologists (ASA) classification 3/4. Ineligibility for BFG was due to unfavourable anatomy or a combination of factors in most cases (31 patients). Two patients had anastomotic aneurysms after previous open surgery. The technical success rate was 100%. One severe intra-operative complication occurred (perforated iliac artery). Two patients (ASA 4) died within 30 days (peri-operative mortality rate 6.1%). Seven patients (21.1%) developed postoperative wound complications. Eight patients died during follow-up of non-aneurysm-related conditions. Twenty-three patients are alive, with mean follow-up of 24.4 months and a survival rate of 69.7%. Two complications occurred during long-term follow-up, namely 1 case of graft sepsis and 1 of FFBP occlusion. Conclusion. AUI with FFBP is a safe, effective and durable alternative in high-risk patients with AAAs where standard open repair is contraindicated and BFG repair is not possible owing to unfavourable aneurysm morphology.

  3. Visceral hybrid reconstruction of thoracoabdominal aortic aneurysm after open repair of type a aortic dissection by the Bentall procedure with the elephant trunk technique: A case report

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2014-01-01

    Full Text Available Introduction. Reconstruction of chronic type B dissection and thoracoabdominal aortic aneurysm (TAAA remaining after the emergency reconstruction of the ascending thoracic aorta and aortic arch for acute type A dissection represents one of the major surgical challenges. Complications of chronic type B dissection are aneurysmal formation and rupture of an aortic aneurysm with a high mortality rate. We presented a case of visceral hybrid reconstruction of TAAA secondary to chronic dissection type B after the Bentall procedure with the elephant trunk technique due to acute type A aortic dissection in a high-risk patient. Case report. A 62 year-old woman was admitted to our institution for reconstruction of Crawford type I TAAA secondary to chronic dissection. The patient had had an acute type A aortic dissection 3 years before and undergone reconstruction by the Bentall procedure with the elephant trunk technique with valve replacement. On admission the patient had coronary artery disease (myocardial infarction, two times in the past 3 years, congestive heart disease with ejection fraction of 25% and chronic obstructive pulmonary disease. On computed tomography (CT of the aorta TAAA was revealed with a maximum diameter of 93 mm in the descending thoracic aorta secondary to chronic dissection. All the visceral arteries originated from the true lumen with exception of the celiac artery (CA, and the end of chronic dissection was below the origin of the superior mesenteric artery (SMA. The patient was operated on using surgical visceral reconstruction of the SMA, CA and the right renal artery (RRA as the first procedure. Postoperative course was without complications. Endovascular TAAA reconstruction was performed as the second procedure one month later, when the elephant trunk was used as the proximal landing zone for the endograft, and distal landing zone was the level of origin of the RRA. Postoperatively, the patient had no neurological deficit and

  4. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young [Dept. of Radiology, Chonnam National University Hospital, Chonnam National University School of Medicine, Gwangju (Korea, Republic of); Kim, Soo Hyun; Chang, Nam Kyu [Dept. of Radiology, Chonnam National University Hwasun Hospital, Chonnam National University School of Medicine, Hwasun (Korea, Republic of)

    2013-02-15

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  5. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  6. The outcome of abdominal aortic aneurysm repair in northern Malaysia.

    Science.gov (United States)

    Lakhwani, M N; Yeoh, K C; Gooi, B H; Lim, S K

    2003-08-01

    A prospective study of all infrarenal abdominal aortic aneurysm (AAA) repairs both as electives and emergencies in Penang between January 1997 to December 2000 is presented. The objectives of the study were to determine the age, gender, racial distribution of the patients, the incidence, and risk factors and to summarize treatments undertaken and discuss the outcome. Among the races, the Malays were the most common presenting with infrarenal AAA. The mean age of patients operated was 68.5 years. Males were more commonly affected compared to females (12:1). Most infrarenal AAA repairs were performed as emergency operations, 33 cases (61.1%) compared to electives, 21 cases (38.9%). Total survival was 70.3% (elective 85.7%; emergency 57.6%). Mortality rate was 31.5% and the primary reason is the lack of operating time available for urgent operation and for treatment of concurrent disease states. Mycotic aneurysm with its triad of abdominal pain, fever and abdominal mass resulted in a significantly higher mortality (46.6%). Ninety six percent of the infrarenal AAA had transverse diameter greater than 6 cm. Morphologically 90.7% were fusiform AAA rather than saccular aneurysm (9.3%). Pulmonary complications (35.2%) were more common than cardiac complications (11.1%) possibly related to the urgent nature of the operation, smoking or history of pulmonary tuberculosis. Bleeding (14.8%) was the most common cause of mortality in ruptured mycotic infrarenal AAA.

  7. Process improvements reduce utilization of resources for aortic aneurysm repair.

    Science.gov (United States)

    Schwarcz, T H; Yavorski, C C; Endean, E D; Kwolek, C J; Hyde, G L

    1998-01-01

    In conjunction with the VA reorganization to promote greater efficiency of health care provision, ambulatory surgery (AS) programs have been created. These programs institute outpatient preoperative assessment and operative management. This study examines the impact of these process changes on resources utilized by patients requiring repair of abdominal aortic aneurysms (AAAs). The medical records of 15 consecutively treated patients undergoing elective, infrarenal AAA repair before (1992-1993) and after (1995-1996) AS implementation were reviewed. Resource utilization was assessed by evaluating preoperative tests performed (inpatient or outpatient), ICU days, and inpatient length of stay (LOS). Postoperative morbidity and mortality were noted. Patient age, AAA size, and prevalence of diabetes mellitus, hypertension, cardiac disease, COPD, and tobacco use were similar between the two groups. Abdominal ultrasound, CT scanning, and angiography were significantly more frequently performed on an outpatient basis after implementation of the AS program. The median preoperative LOS was reduced in the AS group (1 vs 6 days, P = 0.001, Student t test), resulting in a lower inpatient LOS (11 vs 16, P < 0.01, Student t test). All patients survived and the incidence of complications was similar between the groups. Hospital resource utilization was significantly decreased, largely by shifting preoperative assessment to the outpatient setting. This study illustrates that benefits of an ambulatory surgery program can be extended beyond facilitating outpatient operations and should result in decreased length of hospitalization for other major surgical procedures, such as abdominal aortic aneurysm repair.

  8. GIA-Aneurysmorrhaphy and Dermal Detachment: A Novel Technique to Repair Arteriovenous Fistula Aneurysms.

    Science.gov (United States)

    Chang, Jason; Prema, Jateen; Pedersen, Rose; Li, Yiping; Liebl, Max; Patel, Kaushal; Mueller, Mark

    2016-05-01

    This report describes a simplified technique for management of aneurysmal arteriovenous fistulas along with results of initial clinical experience in 12 patients. Various techniques have been described which seek to repair the arteriovenous fistula and lengthen its duration of use. Here, we introduce the GIA-aneurysmorrhaphy and dermal detachment (GADD) procedure, a novel technique which requires minimal dissection to decompress tension on the overlying skin. Transverse incisions were made proximally and distally to the aneurysmal segment, which was then bluntly dissected along its length on either side. A GIA stapler is then fired along the longitudinal axis, narrowing the lumen of the fistula and separating the aneurysm from the skin. After the operation, the arteriovenous fistulae were used continuously until death (1 patient for 12 months), until thrombosis (1 patient for 13 months), or continue to be in use (9 patients, mean patency 18 months). One patient underwent conversion to open aneurysmorrhaphy due to intraoperative fistula occlusion. Five patients resumed hemodialysis immediately, while the remaining resumed hemodialysis within 3 months. The most common complication was cellulitis (3 patients). The GADD procedure as described in this report offers an effective and low-risk option for the management of venous aneurysms with threatened skin in hemodialysis patients.

  9. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo [Dept. of Radiology, Samsugn Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Young Wook; Kim, Dong Ik [Dept. of Surgery, Samsugn Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  10. Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M.; Voshage, G.; Landwehr, P. [Klinik fuer Diagnostische und Interventionelle Radiologie, Gefaesszentrum Hannover, Diakoniekrankenhaus Henriettenstiftung gGmbH, Hannover (Germany); Busch, T. [Klinik fuer Gefaesschirurgie, Gefaesszentrum Hannover, Diakoniekrankenhaus Henriettenstiftung gGmbH, Hannover (Germany)

    2008-09-15

    As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen Versorgung etabliert. Im Gegensatz zu Letzterer ist die Aneurysmatherapie mittels Stent-Grafts auch bei schwerkranken, nicht operationsfaehigen Patienten moeglich, wobei der Nutzen kontrovers diskutiert wird. Im Gegensatz zur klassischen transabdominellen Operation ist die Stent-Graft-Technik anatomischen Einschraenkungen unterworfen, die aber kuenftig aufgrund bereits abzusehender technischer Weiterentwicklungen eine geringere Rolle spielen werden. Die Diagnostik, die Entscheidung fuer eine endovaskulaere Therapie, die praeinterventionelle Planung und die Nachsorge erfordern den Einsatz bildgebender Verfahren, v. a. der Computer- und Magnetresonanztomographie sowie der Sonographie. Die fuer die endovaskulaere Aneurysmabehandlung relevanten Aspekte der Diagnostik werden dargestellt. Auf die Technik, die Materialien, die Ergebnisse und die Komplikationen der Stent-Graft-Behandlung wird ausfuehrlich eingegangen. (orig.)

  11. Thresholds for Abdominal Aortic Aneurysm Repair in England and the United States.

    Science.gov (United States)

    Karthikesalingam, Alan; Vidal-Diez, Alberto; Holt, Peter J; Loftus, Ian M; Schermerhorn, Marc L; Soden, Peter A; Landon, Bruce E; Thompson, Matthew M

    2016-11-24

    Background Thresholds for repair of abdominal aortic aneurysms vary considerably among countries. Methods We examined differences between England and the United States in the frequency of aneurysm repair, the mean aneurysm diameter at the time of the procedure, and rates of aneurysm rupture and aneurysm-related death. Data on the frequency of repair of intact (nonruptured) abdominal aortic aneurysms, in-hospital mortality among patients who had undergone aneurysm repair, and rates of aneurysm rupture during the period from 2005 through 2012 were extracted from the Hospital Episode Statistics database in England and the U.S. Nationwide Inpatient Sample. Data on the aneurysm diameter at the time of repair were extracted from the U.K. National Vascular Registry (2014 data) and from the U.S. National Surgical Quality Improvement Program (2013 data). Aneurysm-related mortality during the period from 2005 through 2012 was determined from data obtained from the Centers for Disease Control and Prevention and the U.K. Office of National Statistics. Data were adjusted with the use of direct standardization or conditional logistic regression for differences between England and the United States with respect to population age and sex. Results During the period from 2005 through 2012, a total of 29,300 patients in England and 278,921 patients in the United States underwent repair of intact abdominal aortic aneurysms. Aneurysm repair was less common in England than in the United States (odds ratio, 0.49; 95% confidence interval [CI], 0.48 to 0.49; Paneurysm-related death was more common in England than in the United States (odds ratio, 3.60; 95% CI, 3.55 to 3.64; Paneurysm rupture occurred more frequently in England than in the United States (odds ratio, 2.23; 95% CI, 2.19 to 2.27; Paneurysm diameter at the time of repair was larger in England (63.7 mm vs. 58.3 mm, Pabdominal aortic aneurysms and a larger mean aneurysm diameter at the time of repair in England than in the United

  12. A special type of endovascular stent repair with complicated thoracic aneurysm and chronic type B dissection aligned in tandem: double perfusion in true and false distal aorta lumen

    Institute of Scientific and Technical Information of China (English)

    GAN Hui-li; ZHANG Jian-qun

    2008-01-01

    @@ Aortic dissection and aortic aneurysm are two of the most common catastrophic events involving the aorta. Thoracic endovascular aortic repair is now considered as a promising alternative to open surgical graft replacement, The aim of endovascular repair of a thoracic aneurysm is to exclude, and thus depressurize, the aneurismal wall and the aim of the endovascular repair of type B aortic dissection is to obliterate all of the false lumen through thrombosis after sealing the primary entry tears, thus to ensure the true lumen perfusion.

  13. Hybrid-repair of thoraco-abdominal or juxtarenal aortic aneurysm: what the radiologist should know

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Tobias; Pfammatter, Thomas; Hechelhammer, Lukas; Marincek, Borut; Frauenfelder, Thomas [University Hospital Zurich, Department of Medical Radiology, Institute of Diagnostic Radiology, Zurich (Switzerland); Mayer, Dieter; Lachat, Mario [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2010-04-15

    Endovascular aneurysm repair of the infrarenal or thoracic aorta has been shown to be a less invasive alternative to open surgery. A combined aneurysm of the thoracic and abdominal aorta is complex and challenging; the involvement of renal and/or visceral branches requires new treatment methods. A hybrid approach is currently an accepted alternative to conventional surgery. Renal and/or visceral revascularisation enables subsequent stent-graft placement into the visceral portion of the aorta. Knowledge of the surgical procedure and a precise assessment of the vascular morphology are crucial for pre-procedural planning and for detection of post-procedural complications. Multi-detector computed tomography angiography (MDCTA) combined with two- and three-dimensional (2D and 3D) rendering is useful for pre-interventional planning and for the detection of post-procedural complications. Three-dimensional rendering allows proper anatomical analyses, influencing interventional strategies and resulting in a better outcome. With the knowledge of procedure-specific MDCTA findings in various vascular conditions, the radiologist and surgeon are able to perform an efficient pre-interventional planning and follow-up examination. Based on our experience with this novel technique of combined open and endovascular aortic aneurysm treatment, this pictorial review illustrates procedure-specific imaging findings, including common and rare complications, with respect to 2D and 3D post-processing techniques. (orig.)

  14. Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair : A 4-year EUROSTAR experience

    NARCIS (Netherlands)

    Waasdorp, EJ; de Vries, JPPM; Hobo, R; Leurs, LJ; Buth, J; Moll, FL

    2005-01-01

    Our objective was to evaluate the effect of preoperative aneurysm and aortic neck diameter on clinical outcome after infrarenal abdominal endovascular aneurysm repair (EVAR). Data of patients in the European Collaborators Registry on Stent-Graft Techniques for Abdominal Aortic Aneurysm Repair (EUROS

  15. Surgical repair of a giant aneurysm of the right subclavian artery.

    Science.gov (United States)

    Spinelli, Francesco; Stilo, Francesco; Benedetto, Filippo; Lentini, Salvatore

    2010-05-01

    Giant isolated subclavian aneurysm is a rare disease. We report a case of a 66-year-old lady, with a proximal intrathoracic true aneurysm of the right subclavian artery. Due to the absence of a proximal neck, and for the relevant tortuosity of the vessels, we decided to approach the aneurysm through a median sternotomy. The aneurysm was excluded and opened. Then, we performed a direct subclavian-carotid transposition. The postoperative course was uneventful.

  16. Emergency abdominal aortic aneurysm repair with a preferential endovascular strategy : Mortality and cost-effectiveness analysis

    NARCIS (Netherlands)

    Kapma, Marten R.; Groen, Henk; Oranen, Bjorn I.; van der Hilst, Christian S.; Tielliu, Ignace F.; Zeebregts, Clark J.; Prins, Ted R.; van den Dungen, Jan J.; Verhoeven, Eric L.

    2007-01-01

    Purpose: To assess mortality and treatment costs of a new management protocol with preferential use of emergency endovascular aneurysm repair (eEVAR) for acute abdominal aortic aneurysm (AAA). Methods: From September 2003 until February 2005, 49 consecutive patients (45 men; mean age 71 years) with

  17. Suprarenal Fixation Resulting in Intestinal Ischemia after Endovascular Aortic Aneurysm Repair

    NARCIS (Netherlands)

    Pol, Robert A.; Keus, Frederick; Prins, Ted R.; Zeebregts, Clark J.

    2014-01-01

    Endovascular aneurysm repair (EVAR) may be associated with specific stent- and procedure-related complications. Hepatic artery anatomic variability may lead to dramatic consequences when unanticipated. A 64-year-old man presented with a 6-cm abdominal aortic aneurysm, suitable for an EVAR procedure.

  18. Endovascular management of bilateral superior intercostal artery aneurysms following late repair of coarctation of the aorta.

    Science.gov (United States)

    Tapping, C R; Ettles, D F

    2011-08-01

    Endovascular management of massive bilateral superior intercostal artery aneurysms following late surgical repair of juxtaductal coarctation of the aorta is described in a 40-year-old male patient. Both aneurysms were successfully treated by coil embolisation without the need for further surgical intervention.

  19. Multiple mycotic aneurysms due to penicillin nonsusceptible Streptococcus pneumoniae solved with endovascular repair.

    Science.gov (United States)

    Rojas, Alvaro; Mertens, Renato; Arbulo, Douglas; Garcia, Patricia; Labarca, Jaime

    2010-08-01

    Mycotic aneurysm is a life-threatening condition. We report the case of an 83-year-old white female who had pneumonia, and 3 months later she was admitted with multiple sacular mycotic aneurysms due to penicillin nonsusceptible Streptococcus pneumoniae. Successful combination therapy with antibiotics and endovascular repair was done.

  20. Current state in tracking and robotic navigation systems for application in endovascular aortic aneurysm repair

    NARCIS (Netherlands)

    De Ruiter, Quirina M B; Moll, Frans L.; Van Herwaarden, Joost A.

    2015-01-01

    Objective This study reviewed the current developments in manual tracking and robotic navigation technologies for application in endovascular aortic aneurysm repair (EVAR). Methods EMBASE and MEDLINE databases were searched for studies reporting manual tracking or robotic navigation systems that are

  1. General Considerations of Ruptured Abdominal Aortic Aneurysm: Ruptured Abdominal Aortic Aneurysm

    OpenAIRE

    Lee, Chung Won; Bae, Miju; Chung, Sung Woon

    2015-01-01

    Although development of surgical technique and critical care, ruptured abdominal aortic aneurysm still carries a high mortality. In order to obtain good results, various efforts have been attempted. This paper reviews initial management of ruptured abdominal aortic aneurysm and discuss the key point open surgical repair and endovascular aneurysm repair.

  2. Endovascular repair for abdominal aortic aneurysm followed by type B dissection.

    Science.gov (United States)

    Shingaki, Masami; Kato, Masaaki; Motoki, Manabu; Kubo, Yoji; Isaji, Toshihiko; Okubo, Nobukazu

    2016-10-01

    An 86-year-old man with an abdominal aortic aneurysm was diagnosed with type B aortic dissection accompanied by a patent false lumen that started at the distal arch of the thoracic aorta and terminated at the left common iliac artery. Meticulous preoperative assessment detected 3 large intimal tears in the descending aorta, abdominal aortic aneurysm, and left common iliac artery. We performed single-stage thoracic and abdominal endovascular aneurysm repair and concomitant axillary-axillary bypass. The abdominal aortic aneurysm with type B aortic dissection was successfully treated using a single-stage endovascular stent graft, without any complications due to the careful preoperative examinations.

  3. Tuberculous aneurysm of the abdominal aorta: endovascular repair using stent grafts in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei Chiang; Kwak, Byung Kook; Kim, Kyo Nam [Sung Ae General Hospital, Seoul (Korea, Republic of); And Others

    2000-12-01

    Tuberculous aneurysm of the aorta is exceedingly rare. To date, the standard therapy for mycotic aneurysm of the abdominal aorta has been surgery involving in-situ graft placement or extra-anatomic bypass surgery followed by effective anti-tuberculous medication. Only recently has the use of a stent graft in the treatment of tuberculous aortic aneurysm been described in the literature. We report two cases in which a tuberculous aneurysm of the abdominal aorta was successfully repaired using endovascular stent grafts. One case involved is a 42-year-old woman with a large suprarenal abdominal aortic aneurysm and a right psoas abscess, and the other, a 41-year-old man in whom an abdominal aortic aneurysm ruptured during surgical drainage of a psoas abscess. (author)

  4. Endovascular Repair of Internal Mammary Artery Aneurysms in Two Sisters with SMAD3 Mutation.

    Science.gov (United States)

    Nevidomskyte, Daiva; Shalhub, Sherene; Aldea, Gabriel S; Byers, Peter H; Schwarze, Ulrike; Murray, Mitzi L; Starnes, Benjamin

    2017-03-07

    True aneurysms of the internal mammary artery are rare and have been described in association with vasculitis or connective tissue disorders. Herein we describe two cases of familial internal mammary artery aneurysms in two sisters with SMAD3 mutation. The older sister presented at the age of 54 with an incidental diagnosis of a multilobed right internal mammary artery aneurysm (IMA) and the younger sister presented several years earlier with a ruptured left IMA aneurysm at the age of 49. Both sisters had Debakey type I aortic dissections prior to the IMA aneurysm presentation. To our knowledge this is the first time IMA aneurysms has been described in siblings with SMAD3 mutation. In our experience endovascular repair is a feasible and safe treatment option. An assessment of the entire arterial tree is recommended in patients diagnosed with SMAD3 mutations.

  5. Estudo comparativo entre tratamento endovascular e cirurgia convencional na correção eletiva de aneurisma de aorta abdominal: revisão bibliográfica Endovascular elective treatment of the abdominal aortic aneurysm versus conventional open repair: a comparative study

    Directory of Open Access Journals (Sweden)

    Ana Carolina P. Simão

    2009-12-01

    Full Text Available O tratamento eletivo do aneurisma de aorta abdominal é recomendado pela alta morbiletalidade decorrente da eventual ruptura. O objetivo deste trabalho foi comparar o reparo endovascular eletivo com a cirurgia aberta e avaliar as mortalidades hospitalar e perioperatória, em 1 ano, por todas as causas e relacionadas ao aneurisma, a permanência hospitalar, as complicações, as taxas de sobrevida, conversão e reintervenção, a durabilidade do enxerto, o custo-benefício e a relação desses dados com o treinamento da equipe médica responsável pelo tratamento. Realizou-se uma revisão da literatura sobre reparo endovascular versus cirurgia convencional. Foram observados vantagem na sobrevivência perioperatória e menor estresse pós-cirúrgico; no entanto, os benefícios iniciais são perdidos por complicações e reintervenções tardias. Trabalhos baseados nas primeiras gerações de endopróteses superestimam as taxas de mortalidade em curto prazo, complicações e reintervenções. A durabilidade do enxerto, a real vantagem na sobrevida e o custo-benefício são incertos, e outros estudos são necessários para o seguimento em longo prazo.The elective treatment of the abdominal aortic aneurysm is recommended due to the high morbidity and mortality of a possible rupture. The objective of this study was to compare the elective endovascular aneurysm repair with open repair and to analyze the in-hospital and perioperative mortality rate during 1 year related to all causes and to the aneurysm, as well as the postoperative length of hospital stay, complications, survival rates, conversion and reintervention, graft durability, cost-benefit ratio, and relation with the medical team’s experience. A review of the scientific literature about endovascular versus open repair was carried out. We found a higher rate of perioperative survival and less postoperative stress; nevertheless, the initial benefits were lost due to late complications and

  6. Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography.

    LENUS (Irish Health Repository)

    Manning, Brian J

    2012-02-01

    OBJECTIVES: Cumulative radiation dose, cost, and increased demand for computed tomography aortography (CTA) suggest that duplex ultrasonography (DU) may be an alternative to CTA-based surveillance. We compared CTA with DU during endovascular aneurysm repair (EVAR) follow-up. METHODS: Patients undergoing EVAR had clinical and radiological follow-up data entered in a prospectively maintained database. For the purpose of this study, the gold standard test for endoleak detection was CTA, and an endoleak detected on DU alone was assumed to be a false positive result. DU interpretation was performed independently of CTA and vice versa. RESULTS: One hundred thirty-two patients underwent EVAR, of whom 117 attended for follow-up ranging from six months to nine years (mean, 32 months). Adequate aneurysm sac visualisation on DU was not possible in 1.7% of patients, predominantly due to obesity. Twenty-eight endoleaks were detected in 28 patients during follow-up. Of these, 24 were initially identified on DU (four false negative DU examinations), and eight had at least one negative CTA with a positive DU prior to diagnosis. Twenty-three endoleaks were type II in nature and three of these patients had increased sac size. There was one type I and four type III endoleaks. Two of these (both type III) had an increased sac size. Of 12 patients with increased aneurysm size of 5 mm or more at follow-up, five had an endoleak visible on DU, yet negative CTA and a further five had endoleak visualisation on both DU and CTA. Of six endoleaks which underwent re-intervention, all were initially picked up on DU. One of these endoleaks was never demonstrated on CTA and a further two had at least one negative CTA prior to endoleak confirmation. Positive predictive value for DU was 45% and negative predictive value 94%. Specificity of DU for endoleak detection was 67% when compared with CTA, because of the large number of false positive DU results. Sensitivity for DU was 86%, with all

  7. Coagulopathy associated with sac reperfusion for reversing paraplegia after endovascular repair of type II thoracoabdominal aneurysm.

    Science.gov (United States)

    Lioupis, Christos; Katsanos, Konstantinos; Clough, Rachel; Matharu, Nick; Modarai, Bijan; Carrell, Tom; Taylor, Peter

    2013-11-01

    Sac perfusion may be helpful in preventing or reversing spinal cord injury after endovascular repair of thoracoabdominal aneurysms and it has been used as an adjunct to the standard physiologic measures of sustained hypertension and cerebrospinal fluid drainage. Coagulopathy as a result of endoleak after endovascular aneurysm repair has been reported, and very rare cases of treatment after repair of these endoleaks have been described. We report a 73-year-old man who had endovascular repair of a type II thoracoabdominal aneurysm with a branched stent graft. Sac reperfusion was initiated to manage postoperative paraplegia. The paraplegia partially resolved but severe hemorrhagic complications developed that were attributed to sac perfusion-related hyperfibrinolysis. Discontinuation of sac perfusion resolved the coagulopathy but resulted in paraplegia.

  8. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  9. Systemic Inflammatory Response and Severe Thrombocytopenia after Endovascular Thoracic Aortic Aneurysm Repair

    Directory of Open Access Journals (Sweden)

    Valentina Silvestrin

    2017-01-01

    Full Text Available After Endovascular repair of thoracic aortic aneurysm, a systemic inflammatory response, named postimplantation syndrome, can develop. This syndrome is characterized by fever, leukocytosis, and elevated CRP plasma levels and its pathogenetic mechanisms are still unknown. Although this syndrome generally resolves within few days, some patients develop a persisting severe inflammatory reaction leading to mild or severe complications. Here we describe the case of a male patient who developed postimplantation inflammatory syndrome and severe thrombocytopenia after endovascular repair of thoracic aortic aneurysm. Treatment with prednisone (50 mg/bid for two weeks did not improve the clinical and laboratory findings. We utilized danazol, a weak androgen that has been shown to be effective in the treatment of immune and idiopathic thrombocytopenic purpura, and after 12 days of treatment with danazol (200 mg/bid, the patient improved progressively and platelet number increased up to 53,000/μL. Patients undergoing endovascular repair of thoracic aortic aneurysm should be carefully monitored for the development of postimplantation syndrome. This clinical condition is relatively common after the endovascular repair of aortic aneurysm but is rarely observed after endovascular repair of thoracic aortic aneurysms. The different known therapeutical approaches are still empiric, with reported beneficial effects with the use of NSAID, corticosteroids, and danazol.

  10. Systemic Inflammatory Response and Severe Thrombocytopenia after Endovascular Thoracic Aortic Aneurysm Repair

    Science.gov (United States)

    Silvestrin, Valentina; Bonvini, Stefano; Antonello, Michele; Grego, Franco; Vettor, Roberto

    2017-01-01

    After Endovascular repair of thoracic aortic aneurysm, a systemic inflammatory response, named postimplantation syndrome, can develop. This syndrome is characterized by fever, leukocytosis, and elevated CRP plasma levels and its pathogenetic mechanisms are still unknown. Although this syndrome generally resolves within few days, some patients develop a persisting severe inflammatory reaction leading to mild or severe complications. Here we describe the case of a male patient who developed postimplantation inflammatory syndrome and severe thrombocytopenia after endovascular repair of thoracic aortic aneurysm. Treatment with prednisone (50 mg/bid) for two weeks did not improve the clinical and laboratory findings. We utilized danazol, a weak androgen that has been shown to be effective in the treatment of immune and idiopathic thrombocytopenic purpura, and after 12 days of treatment with danazol (200 mg/bid), the patient improved progressively and platelet number increased up to 53,000/μL. Patients undergoing endovascular repair of thoracic aortic aneurysm should be carefully monitored for the development of postimplantation syndrome. This clinical condition is relatively common after the endovascular repair of aortic aneurysm but is rarely observed after endovascular repair of thoracic aortic aneurysms. The different known therapeutical approaches are still empiric, with reported beneficial effects with the use of NSAID, corticosteroids, and danazol. PMID:28154580

  11. Endovascular aneurysm repair utilizing the AneuRx and Talent stent grafts.

    Science.gov (United States)

    Arko, Frank R; Murphy, Erin H

    2008-06-01

    Favorable clinical results combined with increased patient demand for minimally invasive surgery have resulted in an increased application of endovascular aneurysm repair, and this treatment modality is now being extended to younger, healthier patients. While it seems that endovascular aneurysm repair is becoming a desirable option for many patients, it is essential to realize that the feasibility of the procedure may be limited at times by patient anatomy and technical difficulties. Specific anatomical difficulties can be imposed by difficult access, short, tortuous and calcified aortic and iliac landing zones, and the presence of coincident complex iliac aneurysms. This manuscript will discuss the use of 2 approved devices from a single manufacturer (Medtronic, Santa Rosa, Calif) and their clinical results in the treatment of infrarenal abdominal aortic aneurysms. We will discuss technical maneuvers and considerations when encountering difficult anatomical situations and how to avoid long-term complications.

  12. Surgical repair of an idiopathic pulmonary artery aneurysm.

    Science.gov (United States)

    Shiokawa, Yuichi; Ushijima, Tomoki; Oishi, Yasuhisa; Tominaga, Ryuji

    2011-02-01

    We report a rare case of idiopathic pulmonary artery aneurysm (PAA) in a 56-year-old woman without any causative conditions, such as congenital heart disease, inflammation, pulmonary artery hypertension, or systemic vasculitis. She presented with sudden back pain, and examination revealed the PAA. She electively underwent resection of the aneurysm and graft replacement. Pathology examination revealed cystic medial necrosis, which was considered the underlying pathology of the aneurysm.

  13. Mycotic aneurysm in a child with history of coarctation of the aorta repair

    Directory of Open Access Journals (Sweden)

    M Santiago Restrepo

    2014-01-01

    Full Text Available A mycotic aneurysm is a rare condition occasionally seen in patients with a history of prior cardiac or vascular surgery. Here we report the presentation of a mycotic aneurysm in a pediatric patient at the site of prior aortic coarctation repair. This patient′s initial presentation suggested rheumatologic or oncologic disease, and after diagnosis he continued to show evidence of splenic, renal and vascular injury distal to the mycotic aneurysm site while being treated with antibiotics. We discuss the diagnosis, treatment and management of this condition.

  14. The use of fenestrated and branched endovascular aneurysm repair for juxtarenal and thoracoabdominal aneurysms: A systematic review and cost-effectiveness analysis

    NARCIS (Netherlands)

    N. Armstrong (Nigel); L.T. Burgers (Laura); S. Deshpande (Sohan); M.J. Al (Maiwenn); R. Riemsma; S.R. Vallabhaneni; P. Holt (Peter); J.L. Severens (Hans); J. Kleijnen (Jos)

    2015-01-01

    textabstractBackground: Patients with large abdominal aortic aneurysms (AAAs) are usually offered reparative treatment given the high mortality risk. There is uncertainty about how to treat juxtarenal AAAs (JRAAAs) or thoracoabdominal aortic aneurysms (TAAAs). Endovascular repair of an abdominal aor

  15. Emergency endovascular repair of ruptured visceral artery aneurysms

    Directory of Open Access Journals (Sweden)

    Tang Tjun

    2007-07-01

    Full Text Available Abstract Background Visceral artery aneurysms although rare, have very high mortality if they rupture. Case presentation An interesting case of a bleeding inferior pancreaticduodenal artery aneurysm is reported in a young patient who presented with hypovolemic shock while being treated in the hospital after undergoing total knee replacement. Endovascular embolization was successfully employed to treat this patient, with early hospital discharge. Conclusion Prompt diagnosis and endovascular management of ruptured visceral aneuryms can decrease the associated mortality and morbidity.

  16. Basic fibroblast growth factor gene transfection in repair of internal carotid artery aneurysm wall

    Institute of Scientific and Technical Information of China (English)

    Lei Jiao; Ming Jiang; Jinghai Fang; Yinsheng Deng; Zejun Chen; Min Wu

    2012-01-01

    Surgery or interventional therapy has some risks in the treatment of cerebral aneurysm. We established an internal carotid artery aneurysm model by dripping elastase in the crotch of the right internal and external carotid arteries of New Zealand rabbits. Following model induction, lentivirus carrying basic fibroblast growth factor was injected through the ear vein. We found that the longer the action time of the lentivirus, the smaller the aneurysm volume. Moreover, platelet-derived growth factor expression in the aneurysm increased, but smooth muscle 22 alpha and hypertension-related gene 1 mRNA expression decreased. At 1, 2, 3, and 4 weeks following model establishment, following 1 week of injection of lentivirus carrying basic fibroblast growth factor, the later the intervention time, the more severe the blood vessel damage, and the bigger the aneurysm volume, the lower the smooth muscle 22 alpha and hypertension-related gene 1 mRNA expression. Simultaneously, platelet-derived growth factor expression decreased. These data suggest that recombinant lentivirus carrying basic fibroblast growth factor can repair damaged cells in the aneurysmal wall and inhibit aneurysm dynamic growth, and that the effect is dependent on therapeutic duration.

  17. Logistic considerations for a successful institutional approach to the endovascular repair of ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Mayer, Dieter; Rancic, Zoran; Pfammatter, Thomas; Hechelhammer, Lukas; Veith, Frank J; Donas, Konstantin; Lachat, Mario

    2010-01-01

    The value of emergency endovascular aneurysm repair (EVAR) in the setting of ruptured abdominal aortic aneurysm remains controversial owing to differing results. However, interpretation of published results remains difficult as there is a lack of generally accepted protocols or standard operating procedures. Furthermore, such protocols and standard operating procedures often are reported incompletely or not at all, thereby making interpretation of results difficult. We herein report our integrated logistic system for the endovascular treatment of ruptured abdominal aortic aneurysms. Important components of this system are prehospital logistics, in-hospital treatment logistics, and aftercare. Further studies should include details about all of these components, and a description of these logistic components must be included in all future studies of emergency EVAR for ruptured abdominal aortic aneurysms.

  18. Patient Compliance with Surveillance Following Elective Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Godfrey, Anthony D., E-mail: deangodfrey@yahoo.co.uk; Morbi, Abigail H. M., E-mail: a.morbi@soton.ac.uk; Nordon, Ian M., E-mail: ian.nordon@uhs.nhs.uk [University Hospital Southampton NHS Foundation Trust, Unit of Cardiac Vascular and Thoracic Surgery - CV& T, Department of Vascular Surgery (United Kingdom)

    2015-10-15

    PurposeIntegral to maintaining good outcomes post-endovascular aneurysm repair (EVAR) is a robust surveillance protocol. A significant proportion of patients fail to comply with surveillance, exposing themselves to complications. We examine EVAR surveillance in Wessex (UK), exploring factors that may predict poor compliance.MethodsRetrospective analysis of 179 consecutive elective EVAR cases [2008–2013] was performed. 167 patients were male, with the age range of 50–95. Surveillance was conducted centrally (tertiary referral trauma centre) and at four spoke units. Surveillance compliance and predictors of non-compliance including age, gender, co-morbid status, residential location and socioeconomic status were analysed for univariate significance.ResultsFifty patients (27.9 %) were non-compliant with surveillance; 14 (8.1 %) had no imaging post-EVAR. At 1 year, 56.1 % (of 123 patients) were compliant. At years 2 and 3, 41.5 and 41.2 % (of 65 and 34 patients, respectively) were compliant. Four years post-EVAR, only one of eight attended surveillance (12.5 %). There were no statistically significant differences in age (p = 0.77), co-morbid status or gender (p = 0.64). Distance to central unit (p = 0.67) and surveillance site (p = 0.56) was non-significant. While there was a trend towards compliance in upper-middle-class socioeconomic groups (ABC1 vs. C1C2D), correlating with >50 % of non-compliant patients living within <10 mile radius of the central unit, overall predictive value was not significant (p = 0.82).ConclusionsCompliance with surveillance post-EVAR is poor. No independent predictor of non-compliance has been confirmed, but socioeconomic status appears to be relevant. There is a worrying drop-off in attendance beyond the first year. This study highlights a problem that needs to be addressed urgently, if we are to maintain good outcomes post-EVAR.

  19. Management of multiple type Ⅱ endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair

    Institute of Scientific and Technical Information of China (English)

    GUO Da-qiao; LI Wei-miao; JIANG Jun-hao; SHI Zhen-yu; WANG Yu-qi; FU Wei-guo

    2012-01-01

    We reported a case of multiple type Ⅱ endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair.The patient was undergoing warfarin therapy.Duplex ultrasound was applied as the sole surveillance method during follow-up and provided the concerned information for reintervention.The endoleaks were successfully repaired by coil embolization of the collaterals from the internal iliac artery feeding the fourth lumbar artery.

  20. Dynamics of the Aorta Before and After Endovascular Aneurysm Repair : A Systematic Review

    NARCIS (Netherlands)

    van Keulen, J. W.; van Prehn, J.; Prokop, M.; Moll, F. L.; van Herwaarden, J. A.

    2009-01-01

    Objective: An overview of the knowledge of thoracic (TAA), and abdominal aortic aneurysm (AAA) dynamics, before and after endovascular repair, is given. Methods: Medline, EMBASE and the Cochrane database were searched for relevant articles. After inclusion and exclusion, 25 relevant articles reporti

  1. Dynamics of the aorta before and after endovascular aneurysm repair: a systematic review.

    NARCIS (Netherlands)

    Keulen, J.W. van; Prehn, J. van; Prokop, M.; Moll, F.L.; Herwaarden, J.A. van

    2009-01-01

    OBJECTIVE: An overview of the knowledge of thoracic (TAA), and abdominal aortic aneurysm (AAA) dynamics, before and after endovascular repair, is given. METHODS: Medline, EMBASE and the Cochrane database were searched for relevant articles. After inclusion and exclusion, 25 relevant articles reporti

  2. Late neurological recovery of paraplegia after endovascular repair of an infected thoracic aortic aneurysm.

    Science.gov (United States)

    Mees, Barend M E; Bastos Gonçalves, Frederico; Koudstaal, Peter J; Verhagen, Hence J M

    2013-02-01

    Spinal cord ischemia is a potentially devastating complication after thoracic endovascular aorta repair (TEVAR). Patients with spinal cord ischemia after TEVAR often develop paraplegia, which is considered irreversible, and have significant increased postoperative morbidity and mortality. We report the case of a patient with unusual late complete neurologic recovery of acute-onset paraplegia after TEVAR for an infected thoracic aortic aneurysm.

  3. Circumference as an alternative for diameter measurement in endovascular aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Buijs, Ruben V. C.; Greuter, Marcel J. W.; Vainas, Tryfon; de Vries, Bas M. Wallis; Prins, Ted R.; Zeebregts, Clark J.

    2015-01-01

    Appropriate sizing of endografts for endovascular aneurysm repair has traditionally been performed by one standardized method. By measuring the average of the minor and major axes in the sealing zone, the endograft size is traditionally calculated. However, no adequate scientific evaluation has been

  4. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  5. Severe tracheobronchial compression in a patient with Turner′s syndrome undergoing repair of a complex aorto-subclavian aneurysm: Anesthesia perspectives

    Directory of Open Access Journals (Sweden)

    Christopher C .C. Hudson

    2014-01-01

    Full Text Available We present a case of severe tracheobronchial compression from a complex aorto-subclavian aneurysm in a patient with Turner′s syndrome undergoing open surgical repair. Significant airway compression is a challenging situation and requires careful preoperative preparation, maintenance of spontaneous breathing when possible, and consideration of having an alternative source of oxygenation and circulation established prior to induction of general anesthesia. Cardiopulmonary monitoring is essential for safe general anesthesia and diagnosis of unexpected intraoperative events.

  6. Abdominal aortic aneurysms : clinical insights and outcome after endovascular repair

    NARCIS (Netherlands)

    Zandvoort, H.J.A.

    2013-01-01

    Abdominal aortic aneurysm (AAA) is a focal dilatation of the abdominal aorta. The pathophysiology of AAA is a complex multifactorial process and much is still unknown. Histologic and biochemical analysis of AAA wall characteristics can contribute to a better insight in AAA pathophysiology. To make t

  7. Acute Testicular Ischemia following Endovascular Abdominal Aortic Aneurysm Repair Identified in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Nathan Finnerty

    2014-01-01

    Full Text Available Endovascular aneurysm repair (EVAR is perhaps the most widely utilized surgical procedure for patients with large abdominal aortic aneurysms. This procedure is minimally invasive and reduces inpatient hospitalization requirements. The case involves a 72-year-old male who presented to the emergency department with right testicular ischemia two days following EVAR. Given the minimal inpatient hospitalization associated with this procedure, emergency physicians are likely to encounter associated complications. Ischemic and thromboembolic events following EVAR are extremely rare but require prompt vascular surgery intervention to minimize morbidity and mortality.

  8. Traumatic pseudoaneurysm of the brachiocephalic artery following medianoscopy: initial endovascular repair followed by open surgery--a case report.

    Science.gov (United States)

    Biebl, Matthias; Neuhauser, B; Perkmann, R; Tauscher, T; Waldenberger, P; Fraedrich, G

    2003-06-01

    Endovascular stent graft repair of traumatic vessel injuries is gaining worldwide acceptance as a minimally invasive alternative to open surgical repair. However, effective endovascular repair fails if the aneurysm is not completely excluded. Conversion to open surgery may be unavoidable in such cases. Herein we describe the case of a 45-year-old man who was referred to our hospital with a pseudoaneurysm of the proximal brachiocephalic artery caused by biopsy during diagnostic medianoscopy. The pseudoaneurysm was primarily treated by stent-graft implantation into the proximal brachiocephalic artery. As a result of the unfavorable location of the lesion exclusion of the aneurysm failed and the initial therapy had to be extended to open reconstruction of the brachiocephalic artery. A bypass procedure from the aortic arch to the right common carotid artery was performed with reinsertion of the right subclavian artery to exclude the pseudoaneurysm.

  9. Hybrid repair of penetrating aortic ulcer associated with right aortic arch and aberrant left innominate artery arising from aneurysmal Kommerell's diverticulum with simultaneous repair of bilateral common iliac artery aneurysms.

    Science.gov (United States)

    Guo, Yuanyuan; Yang, Bin; Cai, Hongbo; Jin, Hui

    2014-02-01

    We present the first case of a hybrid endovascular approach to a penetrating aortic ulcer on the left descending aorta with a right aortic arch and aberrant left innominate artery arising from an aneurysmal Kommerell's diverticulum. The patient also had bilateral common iliac artery aneurysms. The three-step procedure consisted of a carotid-carotid bypass, followed by endovascular exclusion of the ulcer and the aneurysmal Kommerell's diverticulum, and then completion by covering the iliac aneurysms. The patient had no complications at 18 months after surgery. In such rare configurations, endovascular repair is a safe therapeutic option.

  10. Long-term results after repair of ruptured and non-ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kuzmanović Ilija B.

    2004-01-01

    Full Text Available INTRODUCTION Abdominal aortic aneurysm can be repaired by elective procedure while asymptomatic, or immediately when it is complicated - mostly due to rupture. Treating abdominal aneurysm electively, before it becomes urgent, has medical and economical reason. Today, the first month mortality after elective operations of the abdominal aorta aneurysm is less than 3%; on the other hand, significant mortality (25%-70% has been recorded in patients operated immediately because of rupture of the abdominal aneurysm. In addition, the costs of elective surgical treatment are significantly lower. OBJECTIVE The objective of this study is to compare long-term survival of patients that underwent elective or immediate repair of abdominal aortic aneurysm (due to rupture, and to find out the factors influencing the long-term survival of these patients. MATERIAL AND METHODS Through retrospective review of prospectively collected data of the Institute for Cardiovascular Diseases of Clinical Center of Serbia, Belgrade, 56 patients that had elective surgery and 35 patients that underwent urgent operation due to rupture of abdominal aneurysm were followed up. Only the patients that survived 30 postoperative days were included in this review, and were followed up (ranging from 2 to 126 months. Electively operated patients were followed during 58.82 months on the average (range 7 to 122, and urgently operated were followed over 52.26 months (range 2 to 126. There was no significant difference of the length of postoperative follow-up between these two groups. RESULTS During this period, out of electively operated and immediately operated patients, 27 and 22 cases died, respectively. There was no significant difference (p>0,05a of long-term survival between these two groups. Obesity and early postoperative complications significantly decreased long-term survival of both electively and immediately operated patients. Graft infection, ventral hernia, aneurysm of

  11. Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation

    Directory of Open Access Journals (Sweden)

    Stalder Aurelien F

    2008-06-01

    Full Text Available Abstract Aneurysm formation is a life-threatening complication after operative therapy in coarctation. The identification of patients at risk for the development of such secondary pathologies is of high interest and requires a detailed understanding of the link between vascular malformation and altered hemodynamics. The routine morphometric follow-up by magnetic resonance angiography is a well-established technique. However, the intrinsic sensitivity of magnetic resonance (MR towards motion offers the possibility to additionally investigate hemodynamic consequences of morphological changes of the aorta. We demonstrate two cases of aneurysm formation 13 and 35 years after coarctation surgery based on a Waldhausen repair with a subclavian patch and a Vosschulte repair with a Dacron patch, respectively. Comprehensive flow visualization by cardiovascular MR (CMR was performed using a flow-sensitive, 3-dimensional, and 3-directional time-resolved gradient echo sequence at 3T. Subsequent analysis included the calculation of a phase contrast MR angiography and color-coded streamline and particle trace 3D visualization. Additional quantitative evaluation provided regional physiological information on blood flow and derived vessel wall parameters such as wall shear stress and oscillatory shear index. The results highlight the individual 3D blood-flow patterns associated with the different vascular pathologies following repair of aortic coarctation. In addition to known factors predisposing for aneurysm formation after surgical repair of coarctation these findings indicate the importance of flow sensitive CMR to follow up hemodynamic changes with respect to the development of vascular disease.

  12. Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support

    Directory of Open Access Journals (Sweden)

    Pavel Michalek

    2011-01-01

    Full Text Available We describe the case of an 83-year-old patient requiring repair of a large symptomatic abdominal aortic aneurysm (AAA. The patient was known to have coronary artery disease (CAD with symptoms and signs of significant myocardial dysfunction, left-heart failure, and severe aortic insufficiency. The procedure was performed with the help of both mechanical and pharmacological circulatory support. Distal perfusion was provided by an axillofemoral bypass with a centrifugal pump, with dobutamine and levosimendan administered as pharmacological inotropic support. The patient's hemodynamic status was monitored with continuous cardiac output monitoring and transesophageal echocardiography. No serious circulatory complications were recorded during the perioperative and postoperative periods. This paper suggests a potential novel approach to combined circulatory support in patients with heart failure, scheduled for open abdominal aortic aneurysm repair.

  13. An Update on the Inflammatory Response after Endovascular Repair for Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Eleni Arnaoutoglou

    2015-01-01

    Full Text Available Postimplantation syndrome (PIS is the clinical and biochemical expression of an inflammatory response following endovascular repair of an aortic aneurysm (EVAR. The goal of this review is to provide an update on the inflammatory response after endovascular repair of abdominal aortic aneurysm, discussing its causes and effects on the clinical outcome of the patient. PIS concerns nearly one-third of patients after EVAR. It is generally a benign condition, although in some patients it may negatively affect outcome. The different definitions and conclusions drawn from several studies reveal that PIS needs to be redefined with standardized diagnostic criteria. The type of the endograft’s material seems to play a role in the inflammatory response. Future studies should focus on a better understanding of the underlying pathophysiology, predictors, and risk factors as well as determining whether effective preventive strategies are necessary.

  14. OMNEX surgical sealant in the extracorporeal repair of renal artery aneurysms.

    Science.gov (United States)

    Garcia-Roig, Michael; Gorin, Michael A; Castellan, Miguel; Ciancio, Gaetano

    2011-11-01

    OMNEX (Ethicon, Inc.; Somerville, NJ) is a cyanoacrylate-based synthetic surgical sealant. To date, the use of OMNEX has only been described in a limited number of vascular surgery procedures. We present the cases of two patients who underwent successful extracorporeal renal artery aneurysm repair with the aid of OMNEX sealant. This report is the first evidence to suggest the utility of OMNEX in renovascular surgery.

  15. Failure of aneurysm sac shrinkage after endovascular repair; the effect of mural calcification

    Energy Technology Data Exchange (ETDEWEB)

    Love, M. [Department of Radiology, Royal Victoria Hospital, Belfast (United Kingdom)]. E-mail: mark.love@royalhospitals.n-i.nhs.uk; Wray, A. [Department of Radiology, Royal Victoria Hospital, Belfast (United Kingdom); Worthington, M. [Department of Radiology, Royal Victoria Hospital, Belfast (United Kingdom); Ellis, P. [Department of Radiology, Royal Victoria Hospital, Belfast (United Kingdom)

    2005-12-15

    AIM: To evaluate the effect of abdominal aortic aneurysm wall calcification on subsequent sac shrinkage after endovascular repair. MATERIALS AND METHODS: Seventy-three patients underwent endovascular aneurysm repair. The degree of sac wall calcification on pre-procedural computed tomography (CT) examination was graded from 1 to 4 according to the degree of circumferential involvement. On follow-up CT imaging, the maximum transverse diameter (MTD) of the sac was recorded, as well as the presence or absence of endoleak. In those patients with a non-shrinking aneurysm, but no CT evidence of endoleak, contrast-enhanced ultrasound (USS) was performed. Any patient with an endoleak, however diagnosed, was excluded from the study. Kruskal-Wallis and Spearman's rank correlation coefficient testing was applied to compare the degree of calcification and change in MTD. RESULTS: Sixty-three pre-procedural CT images were available for calcification grading. Six of this group had endoleaks resulting in 57 sets of data being available for the study. A reduction in MTD occurred in 68.25% of these patients by 1 year post-procedure. Our figures show aortic calcification is inversely associated with MTD reduction at 6 months (p=0.01), 1 year (p=0.05) and 2 years (p=0.05). CONCLUSION: This study indicates that the degree of aortic wall calcification is significant in predicting MTD reduction post-endovascular repair. The possible mechanisms and implications of this are discussed.

  16. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); Wisniowski, Brendan; Walker, Philip J. [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia); Bradshaw, Barbara [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); Golledge, Jonathan [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia)

    2014-08-15

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  17. Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Tilea Ioan

    2012-08-01

    Full Text Available Abstract Introduction Local aneurysms after surgical repair of coarctation of the aorta occur mainly in patients surgically treated by Dacron patch plasty during adulthood. The management of these patients is always problematic, with frequent complications and increased mortality rates. Percutaneous stent-graft implantation avoids the need for surgical reintervention. Case presentation We report a case involving the hybrid treatment by stent-graft implantation and transposition of the left subclavian artery to the left common carotid artery of an aneurysmal dilatation of the thoracic aorta that occurred in a 64-year-old Caucasian man, operated on almost 40 years earlier with a Dacron patch plasty for aortic coarctation. Our patient presented to our facility for evaluation with back pain and shortness of breath after minimal physical effort. A physical examination revealed stony dullness to percussion of the left posterior thorax, with no other abnormalities. The results of chest radiography, followed by contrast-enhanced computed tomography and aortography, led to a diagnosis of giant aortic thoracic aneurysm. Successful treatment of the aneurysm was achieved by percutaneous stent-graft implantation combined with transposition of the left subclavian artery to the left common carotid artery. His post-procedural recovery was uneventful. Three months after the procedure, computed tomography showed complete thrombosis of the excluded aneurysm, without any clinical signs of left lower limb ischemia or new onset neurological abnormalities. Conclusions Our patient’s case illustrates the clinical outcomes of surgical interventions for aortic coarctation. However, the very late appearance of a local aneurysm is rather unusual. Management of such cases is always difficult. The decision-making should be multidisciplinary. A hybrid approach was considered the best solution for our patient.

  18. Percutaneous access for endovascular abdominal aortic aneurysm repair: can selection criteria be expanded?

    Science.gov (United States)

    Smith, Stephen T; Timaran, Carlos H; Valentine, R James; Rosero, Eric B; Clagett, G Patrick; Arko, Frank R

    2009-01-01

    Previous reports suggest that percutaneous access for endovascular abdominal aortic aneurysm repair (P-EVAR) is as safe as open access (O-EVAR) in patients with favorable femoral anatomy. Severe femoral artery calcification and obesity have been considered relative contraindications to P-EVAR, but these criteria have not been evaluated. The purpose of this study was to assess the postoperative anatomic changes associated with P-EVAR versus O-EVAR using three-dimensional (3-D) computed tomographic (CT) reconstruction and to evaluate the overall results of the two procedures in a group of patients with suboptimal femoral anatomy. During a recent 26-month period, 173 patients underwent EVAR at our institutions, including 35 P-EVARs. Of these, 22 (63%) had complete pre- and postoperative CT imaging of the femoral arteries. These subjects were compared to 22 matched controls who underwent O-EVAR during the same period. Automated 3-D reconstructions were used to measure the following anatomic femoral artery parameters before and after EVAR: arterial depth, calcification score, minimum diameter and area, and maximum diameter and area. Of the 88 study arteries, 50 underwent open access and 38 percutaneous access (Proglide, n=11; Prostar XL, n=27). Both groups were similar regarding sheath size, number of components, operative time, blood loss, and length of stay. Significantly more O-EVAR subjects suffered groin complications (p=0.02), including five hematomas, two wound infections, two femoral thromboses, and one vessel which required patch repair. In the P-EVAR group there was only one hematoma, which was managed conservatively. There was no difference between the P-EVAR and O-EVAR groups with respect to femoral artery calcification (Agatston scores 667+/-719 vs. 945+/-1,248, p=0.37). Obesity (body mass index >30) was documented in six (27%) of both the P-EVAR and O-EVAR groups (p=nonsignificant). Pre- and postoperative CT-derived anatomic data showed a significant

  19. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  20. Unfavorable iliac artery anatomy causing access limitations during endovascular abdominal aortic aneurysm repair: application of the endoconduit technique

    Directory of Open Access Journals (Sweden)

    Rodrigo Gibin Jaldin

    2014-12-01

    Full Text Available Endovascular aneurysm repair (EVAR is already considered the first choice treatment for abdominal aortic aneurysms (AAA. Several different strategies have been used to address limitations to arterial access caused by unfavorable iliac artery anatomy. The aim of this report is to illustrate the advantages and limitations of each option and present the results of using the internal endoconduit technique and the difficulties involved.

  1. Robot-assisted fenestrated endovascular aneurysm repair (FEVAR) using the Magellan system.

    Science.gov (United States)

    Riga, Celia V; Bicknell, Colin D; Rolls, Alexander; Cheshire, Nicholas J; Hamady, Mohamad S

    2013-02-01

    A 67-year-old man underwent robot-assisted three-vessel fenestrated endovascular aneurysm repair (FEVAR) for a 7.3-cm juxtarenal aneurysm. The 6-F robotic catheter was manipulated from a remote workstation, away from the radiation source. Robotic cannulation of the left renal artery was achieved within 3 minutes. System setup time was 5 minutes. There were no postoperative complications. Computed tomography angiography performed at discharge and at 4-month follow-up confirmed target vessel patency with no evidence of an endoleak. Selective cannulation of target vessels during FEVAR using this novel technology is feasible. Endovascular robotics may have a role in simplifying complex endovascular tasks and potentially reducing radiation exposure to the operator.

  2. Cholesterol crystal embolism and delayed-onset paraplegia after thoracoabdominal aneurysm repair.

    Science.gov (United States)

    Nasr, Bahaa; Schneider, Fabrice; Marques da Fonseca, Pedro; Gouny, Pierre

    2014-07-01

    Postoperative paraplegia caused by ischemic injury of the spinal cord is the most disabling complication of thoracoabdominal surgery. We described the case of a 75-year-old patient who underwent a thoracoabdominal aneurysm repair (type IV aneurysm according to Crawford classification). The aorta clamping was done at the T11 level without specific medullary protection. The first postoperative week was uneventful. On the postoperative day 8, renal failure and livedo of the left lower limb occurred together with complete hypotonic paraplegia and severe sepsis. Exploratory laparotomy revealed a gangrenous cholecystitis, and skin biopsies showed cholesterol crystals embolisms in the hypodermis small arteries. The patient died on the postoperative day 28 from a multiorgan failure. In this case, paraplegia was due to cholesterol crystal embolism, which migrated secondarily after aortic clamping.

  3. Delayed type Ⅲb endoleak using AnacondaTM stent graft in abdominal aortic aneurysm repair

    Institute of Scientific and Technical Information of China (English)

    WU Zi-heng; Dieter Raithel; QU Le-feng

    2010-01-01

    @@ Endoleaks are defined as the persistence of blood flow outside the lumen of the endoluminal graft but within an aneurysm sac or the adjacent vascular segment being treated by the graft and classified into 5 categories.1,2 Although type Ⅲb endoleaks (fabric defect) have been reported to occur in some divices,3-6 it has never been previously reported with the AnacondaTM endograft (Vascutek, Terumo, Scotland) after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Here we report a delayed type Ⅲb endoleak of AnacondaTM endograft after EVAR for AAA.

  4. Evaluation of texture for classification of abdominal aortic aneurysm after endovascular repair.

    Science.gov (United States)

    García, Guillermo; Maiora, Josu; Tapia, Arantxa; De Blas, Mariano

    2012-06-01

    The use of the endovascular prostheses in abdominal aortic aneurysm has proven to be an effective technique to reduce the pressure and rupture risk of aneurysm. Nevertheless, in a long-term perspective, complications such as leaks inside the aneurysm sac (endoleaks) could appear causing a pressure elevation and increasing the danger of rupture consequently. At present, computed tomographic angiography (CTA) is the most common examination for medical surveillance. However, endoleak complications cannot always be detected by visual inspection on CTA scans. The investigation on new techniques to detect endoleaks and analyse their effects on treatment evolution is of great importance for endovascular aneurysm repair (EVAR) technique. The purpose of this work was to evaluate the capability of texture features obtained from the aneurysmatic thrombus CT images to discriminate different types of evolutions caused by endoleaks. The regions of interest (ROIs) from patients with different post-EVAR evolution were extracted by experienced radiologists. Three techniques were applied to each ROI to obtain texture parameters, namely the grey level co-occurrence matrix (GLCM), the grey level run length matrix (GLRLM) and the grey level difference method (GLDM). The results showed that GLCM, GLRLM and GLDM features presented a good discrimination ability to differentiate between favourable or unfavourable evolutions. GLCM was the most efficient in terms of classification accuracy (93.41% ± 0.024) followed by GLRLM (90.17% ± 0.077) and finally by GLDM (81.98% ± 0.045). According to the results, we can consider texture analysis as complementary information to classified abdominal aneurysm evolution after EVAR.

  5. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  6. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Directory of Open Access Journals (Sweden)

    Alex Aparecido Cantador

    Full Text Available Abstract Objective: To compare duplex ultrasound and computed tomography (CT angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01. Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation.

  7. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study*

    Science.gov (United States)

    Cantador, Alex Aparecido; Siqueira, Daniel Emílio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fábio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. PMID:27777476

  8. [Case of neuroleptic malignant syndrome following open heart surgery for thoracic aortic aneurysm with parkinson's disease].

    Science.gov (United States)

    Shinoda, Maiko; Sakamoto, Mik; Shindo, Yuki; Ando, Yumi; Tateda, Takeshi

    2013-12-01

    An 80-year-old woman with Parkinson's disease was scheduled for open heart surgery to repair thoracic aortic aneurysm. Parkinson's symptoms were normally treated using oral levodopa (200 mg), selegiline-hydrochloride (5 mg), bromocriptine-mesilate (2 mg), and amantadine-hydrochloride (200 mg) daily. On the day before surgery, levodopa 50mg was infused intravenously. Another 25 mg of levodopa was infused immediately after surgery. Twenty hours later, the patient developed tremors, heyperventilation, but no obvious muscle rigidity. Two days after surgery, the patient exhibited high fever, hydropoiesis, elevated creatine kinase, and a rise in blood leukocytes. She was diagnosed with neuroleptic malignant syndrome. She was intubated, and received dantrolene sodium. Symptoms of neuroleptic malignant syndrome disappeared on the fourth postoperative day. The stress of open heart surgery, specifically extracorporeal circulation and concomitant dilution of levodopa, triggered neuroleptic malignant syndrome in this patient. Parkinson's patients require higher doses of levodopa prior to surgery to compensate and prevent neuroleptic malignant syndrome after surgery.

  9. Fenestrated endovascular aortic repair for juxtarenal abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    GUO Wei; ZHANG Hong-peng; LIU Xiao-ping; JIA Xin; XIONG Jiang; MA Xiao-hui

    2013-01-01

    Background Endovascular stent-graft with fenestration can improve proximal sealing in patients with juxtarenal abdominal aortic aneurysm (JAAA).The purpose of this study was to describe our primary experience and evaluate the safety and efficacy of fenestrated device for JAAA in high-risk patients.Methods Between March 2011 and May 2012,nine male patients (mean age,(79.6±8.6) years) with asymptomatic JAAAs underwent elective deployment of the Zenith fenestrated stent-grafts at a single institution.All patients were treated in the hybrid operating room under general anesthesia.Follow-up computed tomography angiography (CTA) was routinely performed before discharge,at 3,6,and 12 months and annually thereafter.Results Procedural success was achieved in all cases.Total sixteen small fenestrations,two large fenestrations and eight scallops were used.Intra-operative complications occurred in four patients,which included one proximal type Ⅰ endoleak,two type Ⅱ endoleaks,and one renal artery dissection.The mean hospital stay was (8.9±1.4) days,mean blood loss was (360.5±46.8) ml,and mean iodinated contrast volume was (230.6±58.3) ml.The mean follow-up time was (7.6±4.2) months.The visceral graft patency was 100% until now.One patient had an increase of serum creatinine of more than 30%,but did not require dialysis.No patients died,no stent fractured,and migration were diagnosed during the follow-up.Conclusions The early results of fenestrated device for high-risk patients with complex JAAAs are satisfactory.However,long-term fenestrated graft durability and branch vessel patency remain to be determined.

  10. Endovascular Aneurysm Repair: Is Imaging Surveillance Robust, and Does It Influence Long-term Mortality?

    Energy Technology Data Exchange (ETDEWEB)

    Waduud, Mohammed Abdul, E-mail: m.a.waduud@doctors.org.uk [Glasgow Royal Infirmary, Department of Surgery (United Kingdom); Choong, Wen Ling, E-mail: wenlingchoong@nhs.net [Aberdeen Royal Infirmary, NHS Grampian, Department of Surgery (United Kingdom); Ritchie, Moira, E-mail: moirasim9@gmail.com; Williams, Claire, E-mail: c.williams.3@research.gla.ac.uk [University of Glasgow, Institute of Health and Wellbeing Glasgow (United Kingdom); Yadavali, Reddi, E-mail: reddi.yadavali@nhs.net [Aberdeen Royal Infirmary, NHS Grampian, Department of Radiology (United Kingdom); Lim, Shueh, E-mail: s.lim.06@aberdeen.ac.uk [Royal Infirmary of Edinburgh, NHS Lothian, Department of Radiology (United Kingdom); Buchanan, Fraser, E-mail: f.buchanan.11@aberdeen.ac.uk [University of Aberdeen, The School of Medicine and Dentistry (United Kingdom); Bhat, Raj, E-mail: raj.bhat@nhs.net [Ninewells Hospital, NHS Tayside, Department of Radiology (United Kingdom); Ramanathan, Krishnappan, E-mail: k.ramanathan@dundee.ac.uk [University of Dundee, School of Medicine (United Kingdom); Ingram, Susan, E-mail: susan.ingram@luht.scot.nhs.uk; Cormack, Laura, E-mail: lgcormack@googlemail.com [Royal Infirmary of Edinburgh, NHS Lothian, Department of Radiology (United Kingdom); Moss, Jonathan G., E-mail: jon.moss@ggc.scot.nhs.uk [Gartnavel General Hospital, Department of Radiology (United Kingdom)

    2015-02-15

    PurposeEndovascular aneurysm repair (EVAR) is the dominant treatment strategy for abdominal aortic aneurysms. However, as a result of uncertainty regarding long-term durability, an ongoing imaging surveillance program is required. The aim of the study was to assess EVAR surveillance in Scotland and its effect on all-cause and aneurysm-related mortality.MethodsA retrospective analysis of all EVAR procedures carried out in the four main Scottish vascular units. The primary outcome measure was the implementation of post-EVAR imaging surveillance across Scotland. Patients were identified locally and then categorized as having complete, incomplete, or no surveillance. Secondary outcome measures were all-cause mortality and aneurysm-related mortality. Cause of death was obtained from death certificates.ResultsData were available for 569 patients from the years 2001 to 2012. All centers had data for a minimum of 5 contiguous years. Surveillance ranged from 1.66 to 4.55 years (median 3.03 years). Overall, 53 % had complete imaging surveillance, 43 % incomplete, and 4 % none. For the whole cohort, all-cause 5-year mortality was 33.5 % (95 % confidence interval 28.0–38.6) and aneurysm-related mortality was 4.5 % (.8–7.3). All-cause mortality in patients with complete, incomplete, and no imaging was 49.9 % (39.2–58.6), 19.1 % (12.6–25.2), and 47.2 % (17.7–66.2), respectively. Aneurysm-related mortality was 3.7 % (1.8–7.4), 4.4 % (2.2–8.9), and 9.5 % (2.5–33.0), respectively. All-cause mortality was significantly higher in patients with complete compared to incomplete imaging surveillance (p < 0.001). No significant differences were observed in aneurysm-related mortality (p = 0.2).ConclusionOnly half of EVAR patients underwent complete long-term imaging surveillance. However, incomplete imaging could not be linked to any increase in mortality. Further work is required to establish the role and deliverability of EVAR imaging surveillance.

  11. A Rare Complication of Spinal Cord Ischemia Following Endovascular Aneurysm Repair of an Infrarenal Abdominal Aortic Aneurysm with Arteriosclerosis Obliterans: Report of a Case

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Inoue, Kentaro; Aoyagi, Yukihiko; Matsuda, Daisuke; Tanaka, Shinichi; Okadome, Jun; Maehara, Yoshihiko

    2016-01-01

    We herein report a case of a rare complication of spinal cord ischemia (SCI) following endovascular aneurysm repair (EVAR). Computed tomography showed stenosis and calcification of bilateral iliac arteries and a saccular aneurysm of the terminal aorta. Paraplegia occurred soon after balloon angioplasty of iliac arteries and EVAR. Cerebrospinal fluid drainage was not performed because the patient was on dual antiplatelet drugs. The patient was treated with intravenous methylpredonisolone and naloxone; however, this did not improve his paraplegia. SCI after EVAR is extremely rare and unpredictable complication, however, physicians should be aware of SCI after EVAR in patients with atherosclerosis. PMID:27738476

  12. Endovascular Aneurysm Repair (EVAR) for Infra-renal Abdominal Aortic Aneurysm (AAA) under Local Anaesthesia - Initial Experience in Hospital Kuala Lumpur.

    Science.gov (United States)

    Syed, A; Zainal, A A; Hanif, H; Naresh, G

    2012-12-01

    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysm undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All four patients were males with a mean age of 66.7 years. Only one required ICU stay of two days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).

  13. Aneurysm in the brain

    Science.gov (United States)

    ... aneurysms Medical problems such as polycystic kidney disease , coarctation of the aorta , and endocarditis High blood pressure, ... Read More Aneurysm Brain aneurysm repair Brain surgery Coarctation of the aorta Endovascular embolization Epilepsy - overview Incidence ...

  14. Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair

    Institute of Scientific and Technical Information of China (English)

    Xiao Yang; Yue-Xin Chen; Bo Zhang; Yu-Xin Jiang; Chang-Wei Liu; Rui-Na Zhao; Qiong Wu

    2015-01-01

    Background:Endovascular aneurysm repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms.Postoperative endoleak is the most common complication of EVAR.Computed tomography angiography (CTA),which is routine for follow-up,has side effects (e.g.,radiation) and also has a certain percentage of missed diagnosis.Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA.To investigate the advantages of CEUS,we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak.Methods:Post-EVAR patients,who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014.All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination.Size,location,microbubble dispersion,and hemodynamic characteristics of leaks were recorded.Comparison between the diagnosis of CEUS and CDFI was conducted using Fisher's exact test and clinical outcomes of all patients were followed up.Results:Sixteen patients were enrolled,and 12 (75%) had endoleaks with verified types by CEUS.Among 12 cases of endoleaks were positive by CEUS,10 were CDFI-positive,and the four CEUS-negative cases were all negative by CDFI.The diagnostic values of CEUS and CDFI were statistically different (P =0.008).Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results.One patient with type Ⅲ endoleak had open surgery when endovascular repair failed.Conclusions:CEUS is a new,safe,and effective means for detection ofendoleaks post-EVAR.This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category.

  15. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  16. Transretroperitoneal CT-guided embolization of growing internal iliac artery aneurysm after repair of abdominal aortic aneurysm: a transretroperitoneal approach with intramuscular lidocaine injection technique.

    Science.gov (United States)

    Park, Joon Young; Kim, Shin Jung; Kim, Hyoung Ook; Kim, Yong Tae; Lim, Nam Yeol; Kim, Jae Kyu; Chung, Sang Young; Choi, Soo Jin Na; Lee, Ho Kyun

    2015-02-01

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  17. Renal replacement therapies after abdominal aortic aneurysm repair--a review.

    Science.gov (United States)

    Hudorović, Narcis; Lovricević, Ivo; Brkić, Petar; Ahel, Zaky; Vicić-Hudorović, Visnja

    2011-09-01

    The objective of this review is to assess the incidence of postoperative acute renal failure that necessitates the application of hemofiltration and to determine the factors that influence the outcome in patients undergoing surgical repair of abdominal aortic aneurysm. In addition, the review aims to assess the outcomes of postoperative early hemofiltration as compared to late intensive hemofiltration. Different forms of renal replacement therapies for use in abdominal aortic aneurysm surgery patients are discussed. Electronic literature searches were performed using Pubmed, Medline, Embase, Sumsearch, Cinahil, The Cochrane Central Register of Controlled Trials and Excerpta Medica. The search identified 419 potentially eligible studies, of which 119 were excluded based on the title and abstract. Of the remaining 300 studies, full articles were collected and re-evaluated. Forty-five articles satisfied our inclusion criteria, of which only 12 were of the IA Level of evidence. The search results indicated that the underlying disease, its severity and stage, the etiology of acute renal failure, clinical and hemodynamic status of the patient, the resources available, and different costs of therapy might all influence the choice of the renal replacement therapy strategy. However, clear guidelines on renal replacement therapy duration are still lacking. Moreover, it is not known whether in acute renal failure patients undergoing abdominal aortic aneurysm surgery, renal replacement therapy modalities can eliminate significant amounts of clinically relevant inflammatory mediators. This review gives current information available in the literature on the possible mechanisms underlying acute renal failure and recent developments in continuous renal replacement treatment modalities.

  18. Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance

    Energy Technology Data Exchange (ETDEWEB)

    Abada, Hicham T.; Sapoval, Marc R.; Mousseaux, Elie; Gaux, Jean-Claude [Department of Cardiovascular and Interventional Radiology, Hopital Europeen Georges Pompidou, 20 rue Leblanc, 75015, Paris (France); Paul, Jean-Francois [Department of Cardiovascular and Interventional Radiology, Hopital Europeen Georges Pompidou, 20 rue Leblanc, 75015, Paris (France); Department of Radiology, Centre Chirugical Marie Lannelongue, 92350, Le Plessis-Robinson (France); De Maertelaer, Viviane [Statistical Unit, Interdisciplinary Research in Human Biology and Nuclear Medicine, University of Brussels, 1070, Brussels (Belgium)

    2003-12-01

    The aim of this study was to determine the variability of various measurement protocols for measurement of abdominal aortic aneurysm (AAA) and the clinical relevance of variability. Three radiologists performed computed tomographic angiography measurements of both the aorta and the largest portion of the aneurysm on selected axial slices. Then measurements of the largest portion of the aneurysm were performed on unselected axial slices, sagittal and coronal reformatted. Finally, aortic volume was calculated. Measurements and volume calculation were performed before and after endovascular repair and assessed: Part 1: interobserver variability for maximum anteroposterior (MAP) and maximum transverse (MTR) diameters on selected slices; part 2: interobserver variability for unselected slices considering MAP and MTR; part 3: interobserver variability considering maximum diameter in any direction (MAD); part 4: interobserver variability for sagittal (SAG) and coronal (COR) free curved multiplanar reformation (MPR); and part 5: volume calculations. We then determined which technique of measurement was the most clinically relevant for detecting changes in aneurysm size or aortic volume. Parts 1 and 2: interobserver variability was 4.1 mm for both MAP and MTR; part 3: interobserver variability was 7 mm for MAD; part 4: interobserver variability was 5.5 mm (COR) and 4.9 mm (SAG); part 5: interobserver variability for volume was 5.5 ml. A combination of MAP and MTR was the most useful for detecting aortic modification. Volume calculation was needed in only a few cases. We recommend avoiding MAD and MPR measurements and suggest instead measuring both maximum anteroposterior and maximum transverse diameters. If aneurysm size remains stable after endovascular repair, aneurysm volume should be measured. (orig.)

  19. Repair of left ventricular aneurysm during off-pump coronary artery bypass surgery

    Institute of Scientific and Technical Information of China (English)

    YU Yang; GU Cheng-xiong; WEI Hua; LIU Rui; CHEN Chang-cheng; FANG Ying

    2005-01-01

    Background Acute myocardial infarction can result in left ventricular aneurysm, which may in turn cause congestive heart failure, ventricular arrhythmia and thromboembolic events. This study evaluates results achieved with a modified linear closure of left ventricular aneurysms during off-pump coronary artery bypass surgery.Methods From January 2001 to May 2004, 75 patients were operated on for nonruptured, postinfarctional, left ventricular aneurysm during off-pump coronary artery bypass surgery. Repair was completed on the beating heart to minimize ischaemia and allow assessment of wall function and viability to guide closure. All patients presented with symptoms of angina and congestive heart failure or ventricular arrhythmia. The majority (75%) of the patients were in NYHA functional class Ⅲ or Ⅳ. Preoperative ejection fraction was 26%±9%. The mean left ventricular, end diastolic diameter was (57.5±7.1) mm. The ventricular preoperative and postoperative performances were compared. χ2 test and Student's t test were used to analyse the outcomes. A P value less than 0.05 was considered significant.Results Hospital mortality was 1.3% (1/75). Coronary artery bypass was performed with an average of (3.3±1.2) grafts per patient. At the time of followup, all the patients had no symptoms. The mean NYHA class and ejection fraction increased significantly (P<0.001). The mean left ventricular, end diastolic diameter decreased significantly (P<0.001). Conclusions Surgical closure of left ventricular aneurysm can be performed during off-pump coronary artery bypass. The operation is associated with a low inhospital mortality and morbidity. A postoperative improvement in the early term cardiac functions and symptoms and quality of life was documented, increasing our expectations of an increased long-term survival.

  20. Provider volume and outcomes for abdominal aortic aneurysm repair, carotid endarterectomy, and lower extremity revascularization procedures.

    LENUS (Irish Health Repository)

    Killeen, Shane D

    2012-02-03

    BACKGROUND: Intuitively, vascular procedures performed by high-volume vascular subspecialists working at high-volume institutions should be associated with improved patient outcome. Although a large number of studies assess the relationship between volume and outcome, a single contemporary compilation of such studies is lacking. METHODS: A review of the English language literature was performed incorporating searches of the Medline, EMBASE, and Cochrane collaboration databases for abdominal aortic aneurysm repair (elective and emergent), carotid endarterectomy, and arterial lower limb procedures for any volume outcome relationship. Studies were included if they involved a patient cohort from 1980 onwards, were community or population based, and assessed health outcomes (mortality and morbidity) as a dependent variable and volume as an independent variable. RESULTS: We identified 74 relevant studies, and 54 were included. All showed either an inverse relationship of variable magnitude between provider volume and mortality, or no volume-outcome effect. The reduction in the risk-adjusted mortality rate (RAMR) for high-volume providers was 3% to 11% for elective abdominal aortic aneurysm (AAA) repair, 2.5 to 5% for emergent AAA repair, 0.7% to 4.7% carotid endarterectomy, and 0.3% to 0.9% for lower limb arterial bypass procedures. Subspeciality training also conferred a considerable morbidity and mortality benefit for emergent AAA repair, carotid endarterectomy, and lower limb arterial procedures. CONCLUSION: High-volume providers have significantly better outcomes for vascular procedures both in the elective and emergent setting. Subspeciality training also has a considerable impact. These data provide further evidence for the specialization of vascular services, whereby vascular procedures should generally be preformed by high-volume, speciality trained providers.

  1. Repair of Chronic Aneurysmal Aortic Dissection Using a Stent Graft and an Amplatzer(®) Vascular Plug: A Case Study.

    Science.gov (United States)

    Kanaoka, Yuji; Ohki, Takao; Ozawa, Hirotsugu

    2017-02-01

    We report a case in which a stent graft and an Amplatzer(®) vascular plug (AVP) were effective for the treatment of chronic aneurysmal aortic dissection. The patient was a 52-year-old man. At 45 years of age, he developed acute aortic dissection, for which he underwent surgery 4 times with prosthetic graft replacement in the abdominal aorta, descending thoracic, ascending aorta (without neck branch reconstruction), and thoracoabdominal aorta with the reconstruction of the celiac, superior mesenteric, and bilateral renal arteries. At the time of thoracoabdominal aortic surgery, strong adhesion was evident, particularly in the thoracoabdominal area. The adhesion was dissected in a part of the chest, and prosthetic graft replacement was performed the following day. Subsequently, the dissection of the residual distal aortic arch enlarged, and the patient was examined at our hospital. Computed tomography (CT) revealed a small intimal tear at the site of anastomosis distal to the graft in the ascending aorta and a large intimal tear in the descending thoracic aorta with a maximum diameter of 67 mm. Furthermore, open repair by prosthetic graft replacement seemed difficult; therefore, treatment with stent grafting was considered. Because the prosthetic graft in the abdomen was extremely tortuous, stent-graft insertion via the femoral artery seemed to be impossible. The planned treatment involved the placement of a thoracic stent graft using the chimney technique which included reconstruction of the brachiocephalic artery and left common carotid arteries using chimney stent graft and coverage of the left subclavian artery. The thoracic stent graft was planned to be inserted via the abdominal prosthetic graft site because the abdominal prosthetic graft was crooked and was located close to the body surface. However, a small intimal tear distal to the graft in the ascending aorta which had not been revealed by intraoperative aortography was detected by the selective

  2. Ruptured abdominal aortic aneurysm.

    Science.gov (United States)

    Sachs, T; Schermerhorn, M

    2010-06-01

    Ruptured abdominal aortic aneurysm (AAA) continues to be one of the most lethal vascular pathologies we encounter. Its management demands prompt and efficient evaluation and repair. Open repair has traditionally been the mainstay of treatment. However, the introduction of endovascular techniques has altered the treatment algorithm for ruptured AAA in most major medical centers. We present recent literature and techniques for ruptured AAA and its surgical management.

  3. Predictors of adverse events after endovascular abdominal aortic aneurysm repair: A meta-analysis of case reports

    Directory of Open Access Journals (Sweden)

    Schlösser Felix JV

    2008-09-01

    Full Text Available Abstract Introduction Endovascular abdominal aortic aneurysm repair is a life-saving intervention. Nevertheless, complications have a major impact. We review the evidence from case reports for risk factors of complications after endovascular abdominal aortic aneurysm repair. Case presentation We selected case reports from PubMed reporting original data on adverse events after endovascular abdominal aortic aneurysm repair. Extracted risk factors were: age, sex, aneurysm diameter, comorbidities, re-interventions, at least one follow-up visit being missed or refusal of a re-intervention by the patient. Extracted outcomes were: death, rupture and (non-device-related complications. In total 113 relevant articles were selected. These reported on 173 patients. A fatal outcome was reported in 15% (N = 26 of which 50% came after an aneurysm rupture (N = 13. Non-fatal aneurysm rupture occurred in 15% (N = 25. Endoleaks were reported in 52% of the patients (N = 90. In half of the patients with a rupture no prior endoleak was discovered during follow-up. In 83% of the patients one or more re-interventions were performed (N = 143. Mortality was higher among women (risk ratio 2.9; 95% confidence interval 1.4 to 6.0, while the presence of comorbidities was strongly associated with both ruptures (risk ratio 1.6; 95% confidence interval 0.9 to 2.9 and mortality (risk ratio 2.1; 95% confidence interval 1.0 to 4.7. Missing one or more follow-up visits (≥1 or refusal of a re-intervention by the patient was strongly related to both ruptures (risk ratio 4.7; 95% confidence interval 3.1 to 7.0 and mortality (risk ratio 3.8; 95% confidence interval 1.7 to 8.3. Conclusion Female gender, the presence of comorbidities and at least one follow-up visit being missed or refusal of a re-intervention by the patient appear to increase the risk for mortality after endovascular abdominal aortic aneurysm repair. Larger aneurysm diameter, higher age and multimorbidity at the time

  4. A modified technique for Gore Excluder limb deployment in difficult iliac anatomy during endovascular abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Vourliotakis, George; Katsargyris, Athanasios; Tielliu, Ignace F. J.; Zeebregts, Clark J.; Verhoeven, Eric L. G.

    2015-01-01

    Complex iliac anatomy including extreme tortuosity constitutes a relative contraindication for endovascular abdominal aortic aneurysm repair with additional risk of limb-graft occlusion. The Gore Excluder limb-graft is a flexible stent-graft, which adapts easily to iliac tortuosity. Nevertheless, th

  5. Unusual perigraft abscess formation associated with stent graft infection after endovascular aortic repair of abdominal aortic aneurysm: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyo Jin; Kim, Song Soo; Ahn, Moon Sang; Lee, Jae Hwan; Shin, Byung Seok; KIm, Jin Hwan [Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2014-03-15

    Although a stent graft infection after endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) is a rare complication, it carries a high mortality and morbidity rate. We report a rare case of stent graft infection that led to an unusual perigraft abscess formation without any associated aortoenteric fistula two years after the EVAR of AAA.

  6. Endovascular treatment of late thoracic aortic aneurysms after surgical repair of congenital aortic coarctation in childhood.

    Directory of Open Access Journals (Sweden)

    Robert Juszkat

    Full Text Available BACKGROUND: In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1 to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2 to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs and (3 to assess outcomes after intravascular treatment for TAAs. METHODS: This study involved 37 asymptomatic patients (26 female and 11 male who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. RESULTS: Follow-up studies revealed TAA in seven cases (19% (including six with the gothic type of the aortic arch and mild recoarctation in other six (16%. Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA, in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. CONCLUSIONS: The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary.

  7. Early Diagnosis and Repair of Double Saccular Aneurysms of the Aortic Arch Associated With Aortic Coarctation in an Infant With Loeys-Dietz Syndrome.

    Science.gov (United States)

    Ilyin, Vladimir N; Kornoukhov, O Ju; Khovrin, Valery V; Kryukov, Vladislav A; Valitova, Asia A; Ilina, Maria V

    2016-03-01

    Multiple saccular aneurysms of the thoracic aorta in neonates and infants are exceedingly rare. An association of these aneurysms with Loeys-Dietz syndrome (LDS) in older age-groups is well known. This case report describes the diagnosis and subsequent successful repair of aortic coarctation associated with double saccular aneurysms of the thoracic aorta in patient with LDS during the first year of life.

  8. Embolization by micro navigation for treatment of persistent type 2 Endoleaks after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Bruno Lorenção de Almeida

    2014-12-01

    Full Text Available Background:Endovascular repair has become established as a safe and effective method for treatment of abdominal aortic aneurysms. One major complication of this treatment is leakage, or endoleaks, of which type 2 leaks are the most common.Objective:To conduct a brief review of the literature and evaluate the safety and effectiveness of embolization by micronavigation for treatment of type 2 endoleaks.Method:A review of medical records from patients who underwent endovascular repair of abdominal aortic aneurysms identified 5 patients with persistent type 2 endoleaks. These patients were submitted to embolization by micronavigation.Results:In all cases, angiographic success was achieved and control CT scans showed absence of type 2 leaks and aneurysm sacs that had reduced in size after the procedure.Conclusion:Treatment of type 2 endoleaks using embolization by micronavigation is an effective and safe method and should be considered as a treatment option for this complication after endovascular repair of abdominal aortic aneurysms.

  9. Embolisation of a Proximal Type I Endoleak Post-Nellix Aortic Aneurysm Repair Complicated by Reflux of Onyx into the Nellix Endograft Limb

    Energy Technology Data Exchange (ETDEWEB)

    Ameli-Renani, S., E-mail: seyedameli@doctors.org.uk; Das, R., E-mail: raj.das@stgeorges.nhs.uk; Weller, A., E-mail: alweller@gmail.com; Chung, R., E-mail: rchung@doctors.org.uk; Morgan, R. A., E-mail: robert.Morgan@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom)

    2015-06-15

    We report the first case of intervention for a proximal type 1 endoleak following Nellix endovascular aneurysm sealing repair of an aortic aneurysm. This was complicated by migration of Onyx into one of the Nellix graft limbs causing significant stenosis. Subsequent placement of a covered stent to affix the Onyx between the stent and the wall of the Nellix endograft successfully restored stent patency.

  10. Are there fewer complications with third generation endografts in endovascular aneurysm repair?

    DEFF Research Database (Denmark)

    Jayia, P; Constantinou, J; Morgan-Rowe, L

    2013-01-01

    . The majority of these endostents are now withdrawn from the commercial market. However, these patients need lifelong surveillance because of a considerable risk of late complications. The materials used in the stent-graft vary with each manufacturer. Low porous fabric, suprarenal fixation and low profile...... of stent-grafts, allowed treatment of complex aortic disease. Custom made solutions incorporate small openings, fenestrations for vessels involved in the aneurysmal disease and is already built in today's technology and available as CE marked devices. The device can be built with combinations of various...

  11. Internal Iliac Artery Embolization during an Endovascular Aneurysm Repair with Detachable Interlock Microcoils

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo ChuL; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu; Park, Jae Young [Inha University Hospital, Inha University School of Medicine, Incheon (Korea, Republic of); Kim, Jang Yong [Dept. of Vascular and Endovascular Surgery, The Catholic University of Korea School of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    The purpose of this study was to evaluate the effectiveness of detachable interlock microcoils for an embolization of the internal iliac artery during an endovascular aneurysm repair (EVAR). A retrospective review was conducted on 40 patients with aortic aneurysms, who had undergone an EVAR between January 2010 and March 2012. Among them, 16 patients were referred for embolization of the internal iliac artery for the prevention of type II endoleaks. Among 16 patients, 13 patients underwent embolization using detachable interlock microcoils during an EVAR. Computed tomographic angiographies and clinical examinations were performed during the follow-up period. Technical success, clinical outcome, and complications were reviewed. Internal iliac artery embolizations using detachable interlock microcoils were technically successful in all 13 patients, with no occurrence of procedure-related complications. Follow-up imaging was accomplished in the 13 cases. In all cases, type II endoleak was not observed with computed tomographic angiography during the median follow-up of 3 months (range, 1-27 months) and the median clinical follow-up of 12 months (range, 1-27 months). Two of 13 (15%) patients had symptoms of buttock pain, and one patient died due to underlying stomach cancer. No significant clinical symptoms such as bowel ischemia were observed. Internal iliac artery embolization during an EVAR using detachable interlock microcoils to prevent type II endoleaks appears safe and effective, although this should be further proven in a larger population.

  12. Surgical repair of an aberrant splenic artery aneurysm: report of a case.

    Science.gov (United States)

    Illuminati, Giulio; LaMuraglia, Glenn; Nigri, Giuseppe; Vietri, Francesco

    2007-03-01

    Aneurysms of the splenic artery are the most common splanchnic aneurysms. Aneurysms of a splenic artery with an anomalous origin from the superior mesenteric artery are however rare, with eight previously reported cases. Their indications for treatment are superposable to those of aneurysms affecting an orthotopic artery. Methods of treatment of this condition include endovascular, minimally invasive techniques and surgical resection. We report one more case of aneurysm of an aberrant splenic artery, treated with surgical resection, and preservation of the spleen.

  13. Successful Aortic Aneurysm Repair in a Woman with Severe von Willebrand (Type 3 Disease

    Directory of Open Access Journals (Sweden)

    Victoria Campbell

    2015-01-01

    Full Text Available von Willebrand disease type 3 (VWD3 is a rare but the most severe form of von Willebrand disease; it is due to almost complete lack of von Willebrand factor activity (VWF:RCo. It is inherited as autosomal recessive trait; whilst heterozygote carriers have mild, or no symptoms, patients with VWD3 show severe bleeding symptoms. In the laboratory, this is characterised by undetectable VWF:Ag, VWF:RCo, and reduced levels of factor VIII < 0.02 IU/dL. The bleeding is managed with von Willebrand/FVIII factor concentrate replacement therapy. In this rare but challenging case we report on the successful excision and repair of an ascending aortic aneurysm following adequate VWF/FVIII factor concentrate replacement using Haemate-P.

  14. [Symptomatic aorto-iliac aneurysm and situs viscerum inversus: case report].

    Science.gov (United States)

    Baccellieri, Domenico; Mirenda, Francesco; Mandolfino, Tommaso; La Spada, Michele; Stilo, Francesco; Spinelli, Francesco

    2006-01-01

    We report a case of infrarenal symptomatic aorto-iliac aneurysm in a patient with acute abdominal pain. The patient was admitted to the emergency care unit for abdominal pain and CT scans showing an infrarenal aorto-iliac aneurysm in a situs viscerum inversus (SVI) totalis syndrome. The patient underwent open aneurysm repair with an aorto-iliac bifurcated graft. This case shows that situs viscerum inversus cannot be considered a technical problem for the surgical treatment of abdominal aortic aneurysm.

  15. Combined general-epidural anesthesia with continuous postoperative epidural analgesia preserves sigmoid colon perfusion in elective infrarenal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Venetiana Panaretou

    2012-01-01

    Full Text Available Background: In elective open infrarenal aortic aneurysm repair the use of epidural anesthesia and analgesia may preserve splanchnic perfusion. The aim of this study was to investigate the effects of epidural anesthesia on gut perfusion with gastrointestinal tonometry in patients undergoing aortic reconstructive surgery. Methods: Thirty patients, scheduled to undergo an elective infrarenal abdominal aortic reconstructive procedure were randomized in two groups: the epidural anesthesia group (Group A, n=16 and the control group (Group B, n=14. After induction of anesthesia, a transanally inserted sigmoid tonometer was placed for the measurement of sigmoid and gastric intramucosal CO 2 levels and the calculation of regional-arterial CO 2 difference (ΔPCO 2 . Additional measurements included mean arterial pressure (MAP, cardiac output (CO, systemic vascular resistance (SVR, and arterial lactate levels. Results: There were no significant intra- and inter-group differences for MAP, CO, SVR, and arterial lactate levels. Sigmoid pH and PCO 2 increased in both the groups, but this increase was significantly higher in Group B, 20 min after aortic clamping and 10 min after aortic declamping. Conclusions: Patients receiving epidural anesthesia during abdominal aortic reconstruction appear to have less severe disturbances of sigmoid perfusion compared with patients not receiving epidural anesthesia. Further studies are needed to verify these results.

  16. Combined general–epidural anesthesia with continuous postoperative epidural analgesia preserves sigmoid colon perfusion in elective infrarenal aortic aneurysm repair

    Science.gov (United States)

    Panaretou, Venetiana; Siafaka, Ioanna; Theodorou, Dimitrios; Manouras, Andreas; Seretis, Charalampos; Gourgiotis, Stavros; Katsaragakis, Stylianos; Sigala, Fragiska; Zografos, George; Filis, Konstantinos

    2012-01-01

    Background: In elective open infrarenal aortic aneurysm repair the use of epidural anesthesia and analgesia may preserve splanchnic perfusion. The aim of this study was to investigate the effects of epidural anesthesia on gut perfusion with gastrointestinal tonometry in patients undergoing aortic reconstructive surgery. Methods: Thirty patients, scheduled to undergo an elective infrarenal abdominal aortic reconstructive procedure were randomized in two groups: the epidural anesthesia group (Group A, n=16) and the control group (Group B, n=14). After induction of anesthesia, a transanally inserted sigmoid tonometer was placed for the measurement of sigmoid and gastric intramucosal CO2 levels and the calculation of regional–arterial CO2 difference (ΔPCO2). Additional measurements included mean arterial pressure (MAP), cardiac output (CO), systemic vascular resistance (SVR), and arterial lactate levels. Results: There were no significant intra- and inter-group differences for MAP, CO, SVR, and arterial lactate levels. Sigmoid pH and PCO2 increased in both the groups, but this increase was significantly higher in Group B, 20 min after aortic clamping and 10 min after aortic declamping. Conclusions: Patients receiving epidural anesthesia during abdominal aortic reconstruction appear to have less severe disturbances of sigmoid perfusion compared with patients not receiving epidural anesthesia. Further studies are needed to verify these results. PMID:23493852

  17. Predictive Factors for Mortality and Morbidity of Ruptured Abdominal Aortic Aneurysm Repair

    Directory of Open Access Journals (Sweden)

    Manabu Shiraishi

    2012-04-01

    Conclusions: Emergency open repair can be safely performed in patients for infrarenal rAAA. In particular, we identified specific independent predictive factors of clinical examination and laboratory studies for mortality, major morbidity and renal insufficiency. [Arch Clin Exp Surg 2012; 1(2.000: 94-101

  18. Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy); Cotroneo, A.R.; Giammarino, A. [Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy); Spigonardo, F. [Department of Vascular Surgery, University ' G. D' Annunzio' , Chieti (Italy); Storto, M.L. [Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2011-07-15

    Purpose: To investigate the possibility of reducing radiation dose exposure while maintaining image quality using multidetector computed tomography angiography (MDCTA) with high-concentration contrast media in patients undergoing follow-up after endovascular aortic repair (EVAR) to treat abdominal aortic aneurysm. Materials and methods: In this prospective, single center, intra-individual study, patients underwent two consecutive MDCTA scans 6 months apart, one with a standard acquisition protocol (130 mAs/120 kV) and 120 mL of iomeprol 300, and one using a low dose protocol (100 mAs/80 kV) and 90 mL of iomeprol 400. Images acquired during the arterial phase of contrast enhancement were evaluated both qualitatively and quantitatively for image noise and intraluminal contrast enhancement. Results: Thirty adult patients were prospectively enrolled. Statistically significantly higher attenuation values were measured in the low-dose acquisition protocol compared to the standard protocol, from the suprarenal abdominal aorta to the common femoral artery (p < 0.0001; all vascular segments). Qualitatively, image quality was judged significantly (p = 0.0002) better with the standard protocol than with the low-dose protocol. However, no significant differences were found between the two protocols in terms of contrast-to-noise ratio (CNR) (13.63 {+-} 6.97 vs. 11.48 {+-} 8.13; p = 0.1058). An overall dose reduction of up to 74% was observed for the low-dose protocol compared with the standard protocol. Conclusion: In repeat follow-up examinations of patients undergoing EVAR for abdominal aortic aneurysm, a low-dose radiation exposure acquisition protocol provides substantially reduced radiation exposure while maintaining a constant CNR and good image quality.

  19. Outcomes and Prognostic Factors of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hye Doo; Lee, Yun Young; Lee, Seung Jin; Yim, Nam Yeol; Kim, Jae Kyu; Choi, Soo Jin Na; Jung, Sang Young [Chonnam National University Hospital, Gwangju (Korea, Republic of); Chang, Nam Kyu [Dept. of Radiology, St. Carollo Hospital, Suncheon (Korea, Republic of); Lim, Jae Hoon [Dept. of Radiology, Donggunsan Hospital, Gunsan (Korea, Republic of)

    2012-09-15

    To evaluate the outcomes and find the prognostic factors of endovascular abdominal aortic aneurysm repair (EVAR) in patients with hostile neck anatomy of the abdominal aorta. This study was performed on 100 patients with abdominal aneurysm who were treated with EVAR between March 2006 and December 2010. We divided the patients into two groups: good neck anatomy (GNA), and hostile neck anatomy (HNA) and then compared the primary success rate and the incidence rate of complications with EVAR between the two groups. Our aim was to determine the factors related to the complications of EVAR among HNA types. There were no significant differences of primary success rate and incidence rate of complications between the two groups. Among the types of HNA, the short neck angle [odd ratio (OR), 4.23; 95% confidence interval (CI), 1.21-18.70; p = 0.023] and large neck angle (OR, 2.58; 95% CI, 0.15-11.85; p = 0.031) showed a low primary success rate. The short neck angle (OR, 2.32; 95% CI, 1.18-12.29; p = 0.002) and large neck angle (OR, 4.67; 95% CI, 0.14-19.07; p = 0.032) showed a high incidence rate of early type 1 complication. In the case of the large neck angle (OR, 3.78; 95% CI, 0.96-20.80; p = 0.047), the large neck thrombus (OR, 2.23; 95% CI, 0.24-7.12; p = 0.035) and large neck calcification (OR, 2.50; 95% CI, 0.08-18.37; p 0.043) showed a high incidence rate of complications within a year. The results suggest that patients with hostile neck anatomy can be treated with EVAR successfully, although there was a higher incidence of complications in patients with a short neck length, severe neck angulation, circumferential thrombosis, and calcified proximal neck.

  20. Clinical trial results of a modified gore excluder endograft: comparison with open repair and original device design.

    Science.gov (United States)

    Curci, John A; Fillinger, Mark F; Naslund, Thomas C; Rubin, Brian G

    2007-05-01

    A multicenter phase II clinical trial of aneurysm treatment was performed with the modified Gore Excluder bifurcated endoprosthesis (m-EBE, n = 193) and compared with previously reported results from the same group of the original unmodified device (EBE, n = 253) or standard open aneurysm exclusion (control, n = 99). Graft modifications were primarily related to the proximal attachment site and included an increase in the length of the external expanded polytetrafluoroethylene and modifications of the anchor configuration. Preprocedural characteristics, periprocedural clinical events, and postprocedural clinical and radiographic follow-up at 1, 6, 12, and 24 months were analyzed with univariate and multivariate statistics. Device placement was successful in all cases, and there were no aneurysm ruptures in any group. Survival to 2 years was similar in all groups. Early major adverse events with the m-EBE were similar to those with the EBE (14.5% vs. 14%, P = 0.9) and markedly reduced compared to the control group (60.6%, P EBE (2% vs. 6% with the EBE, P EBE compared to the EBE during 14- to 28-month follow-up (15.6% vs. 24.9%, P = 0.037), in part due to the difference in reinterventions. The safety and efficacy of the m-EBE are statistically similar to the original device, although there was a reduction in major late adverse events between the two iterations of the endograft. This difference appears to be related to increased operator experience and changing treatment algorithms. Compared with open aneurysm repair, endoluminal repair with the m-EBE offers advantages in the reduction of early major adverse events while maintaining similar survival and rupture-free outcomes in the intermediate term.

  1. Pediatric isolated bilateral iliac aneurysm.

    Science.gov (United States)

    Chithra, R; Sundar, R Ajai; Velladuraichi, B; Sritharan, N; Amalorpavanathan, J; Vidyasagaran, T

    2013-07-01

    Aneurysms are rare in children. Isolated iliac artery aneurysms are very rare, especially bilateral aneurysms. Pediatric aneurysms are usually secondary to connective tissue disorders, arteritis, or mycotic causes. We present a case of a 3-year-old child with bilateral idiopathic common iliac aneurysms that were successfully repaired with autogenous vein grafts.

  2. Aortoenteric Fistula as a Complication of Open Reconstruction and Endovascular Repair of Abdominal Aorta

    Directory of Open Access Journals (Sweden)

    Marek Tagowski

    2014-01-01

    Full Text Available The paper intends to present a review of imaging characteristics of secondary aortoenteric fistula (AEF. Mechanical injury, infection, and adherence of a bowel segment to the aorta or aortic graft are major etiologic factors of AEF after open aortic repair. The pathogenesis of AEF formation after endovascular abdominal aortic repair is related to mechanical failure of the stent-graft, to stent graft infection, and to persistent pressurization of the aneurysmal sac. The major clinical manifestations of AEF comprise haematemesis, melaena, abdominal pain, sepsis, and fever. CT is the initial diagnostic modality of choice in a stable patient. However, the majority of reported CT appearances are not specific. In case of equivocal CT scans and clinical suspicion of AEF, scintigraphy, 67Ga citrate scans or 18F-FDG PET/CT is useful. Diagnostic accuracy of endoscopy in evaluation of AEF is low; nevertheless it allows to evaluate other than AEF etiologies of gastrointestinal bleeding. Without adequate therapy, AEF is lethal. Conventional surgical treatment is associated with high morbidity and mortality. The endovascular repair may be an option in hemodynamically unstable and high-risk surgical patients. We also illustrate an example of a secondary AEF with highly specific albeit rare radiologic picture from our institution.

  3. Surgical repair of true left ventricular aneurysm in an infant: a rare complication after unsuccessful perventricular VSD closure.

    Science.gov (United States)

    Ozyilmaz, Isa; Saygi, Murat; Yildiz, Okan; Erek, Ersin; Guzeltas, Alper

    2014-10-01

    A 2.5-month-old female patient presented for closure of a ventricular septal defect (VSD). Transthoracic echocardiography showed a large muscular ventricular septal defect. After perventricular closure of the defect was performed with an Amplatzer muscular VSD occluder, peroperative transesophageal echocardiography revealed that the device had been implanted in the wrong area of the ventricular septum. The device was retrieved and a large mid-muscular defect with extension to the outlet septum was closed with a patch of Dacron which was secured with 5-0 sutures. A perforation in the ventricular septum due to attempted perventricular device delivery was seen, and it was repaired primarily. In the eighth month of follow-up, transthoracic echocardiography revealed an aneurysm in the posterior wall of the left ventricle. The patient's electrocardiogram showed pathological Q waves and ST-segment elevation in leads DII, DIII, and aVF consistent with subacute inferior myocardial infarction. At subsequent surgery, this was found to be a true aneurysm, located in area of distribution of the obtuse marginal branch of the left circumflex coronary artery in the posterior wall of the left ventricle. The aneurysm was closed off using a Dacron patch, and the sac was resected. Development of a true aneurysm is a rare but important complication of attempted perventricular VSD closure.

  4. The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair

    Energy Technology Data Exchange (ETDEWEB)

    Fossaceca, Rita; Guzzardi, Giuseppe; Cerini, Paolo; Carriero, Alessandro [University Hospital ' ' Maggiore della Carita' ' , Radiology Department, Novara (Italy); Brambilla, Marco; Valzano, Serena [University Hospital ' ' Maggiore della Carita' ' , Medical Physics Department, Novara (Italy); Renghi, Alessandra; Brustia, Piero [University Hospital ' ' Maggiore della Carita' ' , Vascular Surgery Department, Novara (Italy)

    2012-11-15

    To compare the patient radiation dose during endovascular aortic aneurysm repair (EVAR) using different types of radiological systems: a mobile fluoroscopic C-arm, mobile angiographic and fixed angiographic equipment. Dose-area products (DAP) were obtained from a retrospective study of 147 consecutive patients, subjected to 153 EVAR procedures during a 3.5-year period. On the basis of these data, entrance surface dose (ESD) and effective dose (ED) were calculated. EVARs were performed using a fluoroscopic C-arm, mobile or fixed angiographic equipment in 79, 26 and 48 procedures, respectively. Fluoroscopy times were essentially equivalent for all the systems, ranging from 15 to 19 min. The clinical outcomes were not significantly different among the systems. Statistically significant differences among radiological equipment grouping were found for DAP (mobile C-arm: 32 {+-} 20 Gy cm{sup 2}; mobile angiography: 362 {+-} 164 Gy cm{sup 2}; fixed angiography: 464 {+-} 274 Gy cm{sup 2}; P < 10{sup -6}), for ESD (mobile C-arm: 0.18 {+-} 0.11 Gy; mobile angiography: 2.0 {+-} 0.8 Gy; fixed angiography: 2.5 {+-} 1.5 Gy; P < 10{sup -6}) and ED (mobile C-arm: 6.2 {+-} 4.5 mSv; mobile angiography: 64 {+-} 26 mSv; fixed angiography: 129 {+-} 76 mSv; P < 10{sup -6}). Radiation dose in EVAR is substantially less with a modern portable C-arm than with a fixed or mobile dedicated angiographic system. (orig.)

  5. Early in vivo analysis of an endovascular stapler during endovascular aneurysm repair.

    Science.gov (United States)

    Murphy, Erin H; Arko, Frank R

    2009-01-01

    The objective of this article is to describe the use and technique of a novel endostapling device used in an in vivo animal model. Six ovine underwent implantation of a Dacron endograft into the thoracic aorta followed by placement of endoclips proximally and distally. The animals were survived 35 days to evaluate the performance and safety of the endoclip in an animal model prior to clinical trials. The mean time for securing both the proximal and the distal anastomosis was 22 minutes (range 17-31 minutes). All staples were deployed, without the need for repositioning, on the first attempt. There were no complications related to the implant procedure or indwelling clips. Additionally, no endograft migration occurred. At the time of explant, staples were evaluated for depth of penetration and accuracy of placement. The staples had fully penetrated the endograft and vessel wall through the adventitia in 89% (64 of 72) of clips deployed. The staples were placed accurately, within 10 mm of the endograft proximal and distal attachments in 94% (68 of 72) of the clips deployed. Furthermore, endothelialization of the staples was present without surrounding thrombus. Implant sites were scored as normal without surrounding tissue damage by an independent pathologist. The endoclip performed well in creating proximal and distal fixation of the endograft. There were no adverse outcomes related to the endostaple. Future clinical trials should be undertaken to assess its clinical utility during endovascular aneurysm repair.

  6. Endovascular treatment of a small infrarenal abdominal aortic aneurysm causing duodenal obstruction: Case report and literature review.

    Science.gov (United States)

    Esposito, Andrea; Menna, Danilo; Mansour, Wassim; Sirignano, Pasqualino; Capoccia, Laura; Speziale, Francesco

    2015-06-01

    Duodenal obstruction caused by abdominal aortic aneurysm was first described by Osler in 1905 and is named "aortoduodenal syndrome." This condition has always been treated by open surgical repair. We report the first case of aortoduodenal syndrome successfully treated by endovascular aneurysm repair. A 74-year-old male patient referred to our hospital complaining postprandial vomit, reporting a consistent weight loss in the latest weeks. Enhanced computed tomography scans showed a small saccular abdominal aortic aneurysm compressing duodenum and inferior vena cava without any other evident pathological finding. As the patient underwent a successful endovascular treatment of the abdominal aortic aneurysm, symptoms immediately resolved so that he started back to feed and progressively gained body weight. Despite aortoduodenal syndrome is generally caused by large abdominal aortic aneurysm, this condition has to be suspected also in case of small abdominal aortic aneurysm. Differently from what has been reported in literature, endovascular aneurysm repair could be effective in the treatment of aortoduodenal syndrome.

  7. Functional outcome after laparoscopic and open incisional hernia repair

    NARCIS (Netherlands)

    H.H. Eker (Hasan); D. den Hartog (Dennis); W.E. Tuinebreijer (Wim); G.J. Kleinrensink (Gert Jan); H.J. Stam (Henk); J.F. Lange (Johan)

    2010-01-01

    textabstractAbstract: Background: The debate about the advantages of laparoscopic versus open incisional hernia repair is still ongoing. The primary outcomes of already published studies are mainly recurrence, pain and quality of life. Data on postoperative abdominal wall function after these corre

  8. Endovascular repair of multiple infrageniculate aneurysms in a patient with vascular type Ehlers-Danlos syndrome.

    Science.gov (United States)

    Domenick, Natalie; Cho, Jae S; Abu Hamad, Ghassan; Makaroun, Michel S; Chaer, Rabih A

    2011-09-01

    Patients with vascular type Ehler-Danlos syndrome can develop aneurysms in unusual locations. We describe the case of a 33-year-old woman with vascular type Ehlers-Danlos syndrome who developed metachronous tibial artery aneurysms that were sequentially treated with endovascular means.

  9. Computational fluid dynamics evaluation of the cross-limb stent graft configuration for endovascular aneurysm repair.

    Science.gov (United States)

    Shek, Tina L T; Tse, Leonard W; Nabovati, Aydin; Amon, Cristina H

    2012-12-01

    The technique of crossing the limbs of bifurcated modular stent grafts for endovascular aneurysm repair (EVAR) is often employed in the face of splayed aortic bifurcations to facilitate cannulation and prevent device kinking. However, little has been reported about the implications of cross-limb EVAR, especially in comparison to conventional EVAR. Previous computational fluid dynamics studies of conventional EVAR grafts have mostly utilized simplified planar stent graft geometries. We herein examined the differences between conventional and cross-limb EVAR by comparing their hemodynamic flow fields (i.e., in the "direct" and "cross" configurations, respectively). We also added a "planar" configuration, which is commonly found in the literature, to identify how well this configuration compares to out-of-plane stent graft configurations from a hemodynamic perspective. A representative patient's cross-limb stent graft geometry was segmented using computed tomography imaging in Mimics software. The cross-limb graft geometry was used to build its direct and planar counterparts in SolidWorks. Physiologic velocity and mass flow boundary conditions and blood properties were implemented for steady-state and pulsatile transient simulations in ANSYS CFX. Displacement forces, wall shear stress (WSS), and oscillatory shear index (OSI) were all comparable between the direct and cross configurations, whereas the planar geometry yielded very different predictions of hemodynamics compared to the out-of-plane stent graft configurations, particularly for displacement forces. This single-patient study suggests that the short-term hemodynamics involved in crossing the limbs is as safe as conventional EVAR. Higher helicity and improved WSS distribution of the cross-limb configuration suggest improved flow-related thrombosis resistance in the short term. However, there may be long-term fatigue implications to stent graft use in the cross configuration when compared to the direct

  10. Distal small bowel motility and lipid absorption in patients following abdominal aortic aneurysm repair surgery

    Institute of Scientific and Technical Information of China (English)

    Robert J Fraser; Paul Jury; John Dent; Marc Ritz; Addolorata C Di Matteo; Rosalie Vozzo; Monika Kwiatek; Robert Foreman; Brendan Stanley; Jack Walsh; Jim Burnett

    2006-01-01

    AIM: To investigate distal small bowel motility and lipid absorption in patients following elective abdominal aortic aneurysm (AAA) repair surgery.METHODS: Nine patients (aged 35-78 years; body mass index (BMI) range: 23-36 kg/m2) post-surgery for AAA repair, and seven healthy control subjects (20-50 years;BMI range: 21-29 kg/m2) were studied. Continuous distal small bowel manometry was performed for up to 72 h, during periods of fasting and enteral feeding (Nutrison(R)). Recordings were analyzed for the frequency,origin, length of migration, and direction of small intestinal burst activity. Lipid absorption was assessed on the first day and the third day post surgery in a subset of patients using the 13C-triolein-breath test, and compared with healthy controls. Subjects received a 20-min intraduodenal infusion of 50 mL liquid feed mixed with 200 μL 13C-triolein. End-expiratory breath samples were collected for 6 h and analyzed for 13CO2 concentration.RESULTS: The frequency of burst activity in the proximal and distal small intestine was higher in patients than in healthy subjects, under both fasting and fed conditions (P<0.005). In patients there was a higher proportion of abnormally propagated bursts (71% abnormal), which began to normalize by d 3 (25% abnormal) post-surgery.Lipid absorption data was available for seven patients on d 1 and four patients on d 3 post surgery. In patients,absorption on d 1 post-surgery was half that of healthy control subjects (AUC 13CO2 1323 ± 244 vs 2 646 ±365;P< 0.05, respectively), and was reduced to the one-fifth that of healthy controls by d 3 (AUC 13CO2 470 ± 832 vs 2646 ± 365; P< 0.05, respectively).CONCLUSION: Both proximal and distal small intestinal motor activity are transiently disrupted in critically ill patients immediately after major surgery,with abnormal motility patterns extending as far as the ileum. These motor disturbances may contribute to impaired absorption of enteral nutrition, especially when

  11. Systemic inflammatory responses during laparoscopic and open inguinal hernia repair: a randomised prospective study

    DEFF Research Database (Denmark)

    Jess, P; Schultz, Karen; Bendtzen, K;

    2000-01-01

    To see if the inflammatory responses during and after laparoscopic and open inguinal hernia repairs differed.......To see if the inflammatory responses during and after laparoscopic and open inguinal hernia repairs differed....

  12. The Role of Learning in Health Technology Assessments: An Empirical Assessment of Endovascular Aneurysm Repairs in German Hospitals.

    Science.gov (United States)

    Varabyova, Yauheniya; Blankart, Carl Rudolf; Schreyögg, Jonas

    2017-02-01

    Changes in performance due to learning may dynamically influence the results of a technology evaluation through the change in effectiveness and costs. In this study, we estimate the effect of learning using the example of two minimally invasive treatments of abdominal aortic aneurysms: endovascular aneurysm repair (EVAR) and fenestrated EVAR (fEVAR). The analysis is based on the administrative data of over 40,000 patients admitted with unruptured abdominal aortic aneurysm to more than 500 different hospitals over the years 2006 to 2013. We examine two patient outcomes, namely, in-hospital mortality and length of stay using hierarchical regression models with random effects at the hospital level. The estimated models control for patient and hospital characteristics and take learning interdependency between EVAR and fEVAR into account. In case of EVAR, we observe a significant decrease both in the in-hospital mortality and length of stay with experience accumulated at the hospital level; however, the learning curve for fEVAR in both outcomes is effectively flat. To foster the consideration of learning in health technology assessments of medical devices, a general framework for estimating learning effects is derived from the analysis. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd.

  13. Comparação entre os tratamentos aberto e endovascular dos aneurismas da aorta abdominal em pacientes de alto risco cirúrgico Comparison between open and endovascular treatment of abdominal aortic aneurysms in high surgical risk patients

    Directory of Open Access Journals (Sweden)

    Célio Teixeira Mendonça

    2005-09-01

    Full Text Available OBJETIVO: Comparar os resultados dos tratamentos aberto e endovascular de aneurismas da aorta abdominal em pacientes de alto risco cirúrgico. MÉTODOS: O tratamento aberto foi realizado em 31 pacientes, e o endovascular, em 18. Sucesso no tratamento endovascular foi definido como perviedade da endoprótese sem endoleaks ou conversão para tratamento aberto. RESULTADOS: Não houve diferença na mortalidade perioperatória entre o tratamento aberto (dois óbitos [6,45%] em 31 e o endovascular (um óbito [5,55%] em 18 (P = 0,899; também não houve diferença entre a mortalidade tardia no tratamento aberto (dois óbitos [6,9%] em 29 e no endovascular (dois óbitos [11,7%] em 17 (P = 0,572. A taxa de sucesso imediato foi de 100% (31/31 no tratamento aberto e de 66,7% (12/18 no endovascular (P = 0,0006; a taxa de sucesso tardio foi de 100% (27/27 no tratamento aberto e de 73,3% (11/15 no endovascular (P = 0,0047. Os valores médios do tempo de internação na UTI, tempo de internação hospitalar e da perda de sangue para os grupos dos tratamentos aberto e endovascular foram: 65,6 versus 34,1 horas*, 9 versus 5,6 dias* e 932 versus 225 ml*, respectivamente (*P OBJECTIVE: To compare the results of open repair and endoluminal repair of abdominal aortic aneurysms in high surgical risk patients. METHODS: Open repair was performed in 31 patients, and endoluminal repair was performed in 18. Success in the endoluminal repair group was defined as continuing graft function without endoleak or conversion to open repair. RESULTS: No significant difference was found between the perioperative mortality rate for open repair (two deaths [6.45%] in 31 patients and endoluminal repair (one death [5.55%] in 18 patients (P = 0.899; similarly, no significant difference was seen in late mortality between open repair (two deaths [6.9%] in 29 patients and endoluminal repair (two deaths [11.7%] in 17 patients (P = 0.572; The rate of immediate success was 100% (31/31 for

  14. Osteopontin and Osteoprotegerin as Potential Biomarkers in Abdominal Aortic Aneurysm before and after Treatment.

    Science.gov (United States)

    Filis, Konstantinos; Martinakis, Vasilios; Galyfos, George; Sigala, Fragiska; Theodorou, Dimitris; Andreadou, Ioanna; Zografos, Georgios

    2014-01-01

    Aim. Although osteopontin (OPN) and osteoprotegerin (OPG) have been associated with abdominal aortic aneurysms (AAAs), no association of these two biomarkers with AAA surgical or endovascular treatment has been reported. Material and Methods. Seventy-four AAA patients were prospectively selected for open or endovascular repair. All aneurysms were classified (Types A-E) according to aneurysmal extent in CT imaging (EUROSTAR criteria). All patients had preoperative serum OPN and OPG values measurements and 1 week after the procedure. Preoperative and postoperative values were compared with a control group of twenty patients (inguinal hernia repair). Results. Preoperative OPN values in patients with any type of aneurysm were higher than in the control group, while OPG values showed no difference. Postoperative OPN values in AAA patients were higher than in the control group. OPN values increased after open surgery and after EVAR. OPG values increased after open surgery but not after EVAR. There was no difference in OPN/OPG values between EVAR and open surgery postoperatively. Conclusions. OPN values are associated with aneurysm presence but not with aneurysm extent. OPG values are not associated either with aneurysm presence or with aneurysm extent. OPN values increase after AAA repair, independently of the type of repair.

  15. Management and outcomes of isolated renal artery aneurysms in the endovascular era

    NARCIS (Netherlands)

    Buck, Dominique B; Curran, Thomas; McCallum, John C; Darling, Jeremy; Mamtani, Rishi; van Herwaarden, JA; Moll, Frans L; Schermerhorn, Marc L

    2016-01-01

    OBJECTIVE: Isolated renal artery aneurysms are rare, and controversy remains about indications for surgical repair. Little is known about the impact of endovascular therapy on selection of patients and outcomes of renal artery aneurysms. METHODS: We identified all patients undergoing open or endovas

  16. Should Endovascular Repair Be Reimbursed for Low Risk Abdominal Aortic Aneurysm Patients? Evidence from Ontario, Canada

    Directory of Open Access Journals (Sweden)

    Jean-Eric Tarride

    2011-01-01

    Full Text Available Background. This paper presents unpublished clinical and economic data associated with open surgical repair (OSR in low risk (LR patients and how it compares with EVAR and OSR in high risk (HR patients with an AAA > 5.5 cm. Design. Data from a 1-year prospective observational study was used to compare EVAR in HR patients versus OSR in HR and LR patients. Results. Between 2003 and 2005, 140 patients were treated with EVAR and 195 with OSR (HR: 52; LR: 143. The 1-year mortality rate with EVAR was statistically lower than HR OSR patients and comparable to LR OSR patients. One-year health-related quality of life was lower in the EVAR patients compared to OSR patients. EVAR was cost-effective compared to OSR HR but not when compared to OSR LR patients. Conclusions. Despite a similar clinical effectiveness, these results suggest that, at the current price, EVAR is more expensive than open repair for low risk patients.

  17. Left ventricular aneurysm repair with use of a bovine pericardial patch.

    Science.gov (United States)

    Henry, Matthew J; Preventza, Ourania; Cooley, Denton A; de la Cruz, Kim I; Coselli, Joseph S

    2014-08-01

    Left ventricular aneurysm, which can impair systolic function, has a reported incidence of 10% to 35% in patients after myocardial infarction. In a 58-year-old woman who had a history of myocardial infarction, we excised a large left ventricular aneurysm and restored left ventricular geometry with use of a bovine pericardial patch. The aneurysm's characteristics and the patient's preoperative left ventricular ejection fraction of 0.25 had indicated surgical intervention. The patient had an uneventful postoperative course, and her left ventricular ejection fraction was 0.50 to 0.55 on the 4th postoperative day. This case illustrates the value of surgical treatment for patients who have a debilitating left ventricular aneurysm.

  18. Endovascular repair of descending thoracic aortic aneurysm via midsternotomy and without extracorporeal circulation.

    Science.gov (United States)

    Abad, C; Garzon, G; Ponce, G; Reyes, R; Rodriguez, D

    2003-12-01

    A 68-year-old man with peripheral vascular disease and associated risk factors, was diagnosed by CT-scan and aortography with an atherosclerotic descending thoracic aortic aneurysm. The patient was treated by successful endovascular grafting of the aneurysm using a midsternotomy incision and the insertion of a thoracic stent-graft through a T-Dacron tube sutured in the ascending aorta, without the aid of cardiopulmonary bypass.

  19. The effects of aneurysm repair using an aortic prosthesis on the electrical parameters of the muscular layer of the abdominal aorta.

    Science.gov (United States)

    Hauzer, W; Czerski, A; Zawadzki, W; Gnus, J; Ratajczak, K; Nowak, M; Janeczek, M; Witkiewicz, W; Niespielak, P

    2014-12-01

    The study was carried out on 10 swine of 20-30 kg body weight. Five animals were assigned to each of 2 groups. An aneurysm of the abdominal aorta was created experimentally in animals from the first and second study group. After 4 weeks, animals from the second group were subject to aneurysm repair using an aortic prosthesis. During the experiment, we measured the myoelectric activity of the muscular layer of the abdominal aorta and aneurysmal lesion with the ultrasonographic technique. Measurements of the aorta and aneurysmal lesion and histopathological analyses were carried out post-mortem. We found a statistically significant decrease in the myoelectric activity of the aorta on the aorta-straight prosthesis interface and a significant decrease in the thickness of the muscular layer of the aorta on the aorta-prosthesis interface. No similar changes were found for experimentally induced aneurysms of the abdominal aorta. A straight prosthesis graft may not be the perfect option in the treatment of abdominal aortic aneurysm, as it contributes to the remodelling of the tissue on the prosthesis-aorta interface. This may result in the relapse of an aneurysm and post-operative complications.

  20. Open femoral hernia repair: one skin incision for all

    Directory of Open Access Journals (Sweden)

    El-Masry Nabil S

    2009-11-01

    Full Text Available Abstract Background Femoral hernias are relatively uncommon, however they are the most common incarcerated abdominal hernia, with strangulation of a viscus carrying significant mortality. Classically three approaches are described to open femoral hernia repair: Lockwood's infra-inguinal, Lotheissen's trans-inguinal and McEvedy's high approach. Each approach describes a separate skin incision and dissection to access the femoral sac. The decision as to which approach to adopt, predominantly dependent on the suspicion of finding strangulated bowel, is often a difficult one and in our opinion an unnecessary one. Methods We propose a technique for open femoral hernia repair that involves a single skin incision 1 cm above the medial half of the inguinal ligament that allows all of the above approaches to the hernia sac depending on the operative findings. Thus the repair of simple femoral hernias can be performed from below the inguinal ligament. If found, inguinal hernias can be repaired. More importantly, resection of compromised bowel can be achieved by accessing the peritoneal cavity with division of the linea semilunaris 4 cm above the inguinal ligament. This avoids compromise of the inguinal canal, and with medial retraction of the rectus abdominis muscle enables access to the peritoneal cavity and compromised bowel. Discussion This simple technique minimises the preoperative debate as to which incision will allow the best approach to the femoral hernia sac, allow for alteration to a simple inguinal hernia repair if necessary, and more importantly obviate the need for further skin incisions if compromised bowel is encountered that requires resection.

  1. The Impact of Aortic Occlusion Balloon on Mortality After Endovascular Repair of Ruptured Abdominal Aortic Aneurysms: A Meta-analysis and Meta-regression Analysis

    NARCIS (Netherlands)

    Karkos, C.; Papadimitriou, C.; Chatzivasileiadis, T.; Kapsali, N.; Kalogirou, T.; Giagtzidis, I.; Papazoglou, K.

    2015-01-01

    INTRODUCTION:We aimed to investigate whether the use of aortic occlusion balloon (AOB) has an impact on mortality of patients undergoing endovascular repair of ruptured abdominal aortic aneurysms (RAAAs).METHODS:A meta-analysis of the English-language literature was undertaken through February 2013.

  2. Bilateral prevascular herniae – A rare complication of aorto-uniiliac endovascular abdominal aortic aneurysm repair and femoro-femoral bypass

    Directory of Open Access Journals (Sweden)

    Obinna Obinwa

    2015-01-01

    Full Text Available A case of a 78-year-old female with bilateral groin prevascular herniae following an emergency aorto-uniiliac EVAR and femoro-femoral bypass for a ruptured abdominal aortic aneurysm is presented. Primary repair of the herniae was achieved using a preperitoneal approach. The case emphasises a safe approach to dealing with this rare complication.

  3. Reoperation Rates for Laparoscopic vs Open Repair of Femoral Hernias in Denmark

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Bisgaard, Thue; Kehlet, Henrik

    2014-01-01

    IMPORTANCE: In Denmark approximately 10 000 groin hernias are repaired annually, of which 2% to 4% are femoral hernias. Several methods for repair of femoral hernias are used including sutured repair and different types of mesh repair with either open or laparoscopic techniques. The use of many d...

  4. The Impact of Endovascular Treatment on Isolated Iliac Artery Aneurysm Treatment and Mortality

    Science.gov (United States)

    Buck, Dominique B.; Bensley, Rodney P.; Darling, Jeremy; Curran, Thomas; McCallum, John C.; Moll, Frans L.; van Herwaarden, Joost A.; Schermerhorn, Marc L.

    2015-01-01

    Objective Isolated Iliac artery aneurysms are rare, but potentially fatal. The impact of recent trends in the utilization of endovascular iliac aneurysm repair (EVIR) on isolated iliac artery aneurysm-associated mortality is unknown. Methods We identified all patients with a primary diagnosis of iliac artery aneurysm in the NIS from 1988 to 2011. We examined trends in management (open vs. EVIR, elective and urgent) and overall isolated iliac artery aneurysm related deaths (with or without repair). We compared in-hospital mortality and complications for the subgroup of patients undergoing elective open and EVIR from 2000-2011. Results We identified 33,161 patients undergoing isolated iliac artery aneurysm repair from 1988-2011: of which there were 9,016 EVIR and 4,933 open elective repairs from 2000-2011. Total repairs increased after introduction of EVIR from 28 to 71 per 10M US population (Pintroduction of EVIR (4.4 to 2.3 per 10M US population, Pintroduction of EVIR and is associated with lower perioperative mortality, despite a higher burden of comorbid illness. Decreasing iliac artery aneurysm-attributable in-hospital deaths are likely related primarily to lower elective mortality with EVIR rather than rupture prevention. PMID:25943454

  5. Using a Surgeon-modified Iliac Branch Device to Preserve the Internal Iliac Artery during Endovascular Aneurysm Repair: Single-center Experiences and Early Results

    Institute of Scientific and Technical Information of China (English)

    Wei-Wei Wu; Chen Lin; Bao Liu; Chang-Wei Liu

    2015-01-01

    Background:To evaluate the feasibility of a new surgeon-modified iliac branch device (IBD) technique to maintain pelvic perfusion in the management of common iliac artery (CIA) aneurysm during endovascular aneurysm repair (EVAR).Methods:From January 2011 to December 2013,a new surgeon-modified IBD technique was performed in department of vascular surgery of Peking Union Medical College Hospital in five patients treated for CIA aneurysm with or without abdominal aortic aneurysm.A stent-graft limb was initially deployed in vitro,anastomosed with vascular graft,creating a modified IBD reloaded into a larger sheath,with or without a guidewire preloaded into the side branch.The reloaded IBD was then placed in the iliac artery,with a covered stent bridging internal iliac artery and the branch.Finally,a bifurcated stent-graft was deployed,and a limb device was used to connect the main body and IBD.Results:Technical successes were obtained in all patients.The mean follow-up length was 24 months (range:6-38 months).All grafts remained patent without any sign of endoleaks.There were no aneurysm ruptures,deaths,or other complications related to pelvic flow.Conclusions:Using the surgeon-modified IBD to preserve pelvic flow is a feasible endovascular technique and an appealing solution for personalized treatment of CIA aneurysm during EVAR.

  6. Using a Surgeon-modified Iliac Branch Device to Preserve the Internal Iliac Artery during Endovascular Aneurysm Repair: Single-center Experiences and Early Results

    Directory of Open Access Journals (Sweden)

    Wei-Wei Wu

    2015-01-01

    Full Text Available Background: To evaluate the feasibility of a new surgeon-modified iliac branch device (IBD technique to maintain pelvic perfusion in the management of common iliac artery (CIA aneurysm during endovascular aneurysm repair (EVAR. Methods: From January 2011 to December 2013, a new surgeon-modified IBD technique was performed in department of vascular surgery of Peking Union Medical College Hospital in five patients treated for CIA aneurysm with or without abdominal aortic aneurysm. A stent-graft limb was initially deployed in vitro, anastomosed with vascular graft, creating a modified IBD reloaded into a larger sheath, with or without a guidewire preloaded into the side branch. The reloaded IBD was then placed in the iliac artery, with a covered stent bridging internal iliac artery and the branch. Finally, a bifurcated stent-graft was deployed, and a limb device was used to connect the main body and IBD. Results: Technical successes were obtained in all patients. The mean follow-up length was 24 months (range: 6-38 months. All grafts remained patent without any sign of endoleaks. There were no aneurysm ruptures, deaths, or other complications related to pelvic flow. Conclusions: Using the surgeon-modified IBD to preserve pelvic flow is a feasible endovascular technique and an appealing solution for personalized treatment of CIA aneurysm during EVAR.

  7. An Artificial Neural Network Stratifies the Risks of Reintervention and Mortality after Endovascular Aneurysm Repair; a Retrospective Observational study.

    Directory of Open Access Journals (Sweden)

    Alan Karthikesalingam

    Full Text Available Lifelong surveillance after endovascular repair (EVAR of abdominal aortic aneurysms (AAA is considered mandatory to detect potentially life-threatening endograft complications. A minority of patients require reintervention but cannot be predictively identified by existing methods. This study aimed to improve the prediction of endograft complications and mortality, through the application of machine-learning techniques.Patients undergoing EVAR at 2 centres were studied from 2004-2010. Pre-operative aneurysm morphology was quantified and endograft complications were recorded up to 5 years following surgery. An artificial neural networks (ANN approach was used to predict whether patients would be at low- or high-risk of endograft complications (aortic/limb or mortality. Centre 1 data were used for training and centre 2 data for validation. ANN performance was assessed by Kaplan-Meier analysis to compare the incidence of aortic complications, limb complications, and mortality; in patients predicted to be low-risk, versus those predicted to be high-risk.761 patients aged 75 +/- 7 years underwent EVAR. Mean follow-up was 36+/- 20 months. An ANN was created from morphological features including angulation/length/areas/diameters/volume/tortuosity of the aneurysm neck/sac/iliac segments. ANN models predicted endograft complications and mortality with excellent discrimination between a low-risk and high-risk group. In external validation, the 5-year rates of freedom from aortic complications, limb complications and mortality were 95.9% vs 67.9%; 99.3% vs 92.0%; and 87.9% vs 79.3% respectively (p<0.001.This study presents ANN models that stratify the 5-year risk of endograft complications or mortality using routinely available pre-operative data.

  8. Bayesian neural network approach for determining the risk of re-intervention after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Attallah, Omneya; Ma, Xianghong

    2014-09-01

    This article proposes a Bayesian neural network approach to determine the risk of re-intervention after endovascular aortic aneurysm repair surgery. The target of proposed technique is to determine which patients have high chance to re-intervention (high-risk patients) and which are not (low-risk patients) after 5 years of the surgery. Two censored datasets relating to the clinical conditions of aortic aneurysms have been collected from two different vascular centers in the United Kingdom. A Bayesian network was first employed to solve the censoring issue in the datasets. Then, a back propagation neural network model was built using the uncensored data of the first center to predict re-intervention on the second center and classify the patients into high-risk and low-risk groups. Kaplan-Meier curves were plotted for each group of patients separately to show whether there is a significant difference between the two risk groups. Finally, the logrank test was applied to determine whether the neural network model was capable of predicting and distinguishing between the two risk groups. The results show that the Bayesian network used for uncensoring the data has improved the performance of the neural networks that were built for the two centers separately. More importantly, the neural network that was trained with uncensored data of the first center was able to predict and discriminate between groups of low risk and high risk of re-intervention after 5 years of endovascular aortic aneurysm surgery at center 2 (p = 0.0037 in the logrank test).

  9. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  10. Endovascular aneurysm repair alters renal artery movement : A preliminary evaluation using dynamic CTA

    NARCIS (Netherlands)

    Muhs, Bart E.; Teutelink, Arno; Prokop, Matthias; Vincken, Koen L.; Moll, Frans L.; Verhagen, Hence J. M.

    2006-01-01

    Purpose: To observe the natural renal artery motion during cardiac cycles in patients with abdominal aortic aneurysm (AAA) and how the implantation of stent-grafts may distort this movement. Methods: Data on 29 renal arteries from 15 male patients (mean age 72.6 years, range 66-83) treated with Tale

  11. Repair of an Atherosclerotic Coronary Artery Aneurysm by Implantation of a Coronary Covered Stent

    Directory of Open Access Journals (Sweden)

    Antenor Portela

    2002-05-01

    Full Text Available An atherosclerotic aneurysm of the right coronary artery complicated by a recent myocardial infarction was successfully treated with coronary artery stenting, using a device consisting of 2 stents with a layer of expandable polytetrafluorethylene (PTFE placed between them. A follow-up angiograph 5 months after the procedure showed sustained initial results.

  12. Can surgeons assess CT suitability for endovascular repair (EVAR) in ruptured abdominal aortic aneurysm? Implications for a ruptured EVAR trial.

    Science.gov (United States)

    Rayt, Harjeet; Lambert, Kelly; Bown, Matthew; Fishwick, Guy; Morgan, Robert; McCarthy, Mark; London, Nick; Sayers, Robert

    2008-01-01

    The purpose of this study was to determine whether surgeons without formal radiological training are able to assess suitability of patients with ruptured abdominal aortic aneurysms (AAA) for EVAR. The CT scans of 20 patients with AAA were reviewed under timed conditions by six vascular surgeons. Twenty minutes was allocated per scan. They were asked to determine if each aneurysm would be treatable by EVAR in the emergency setting and, if so, to measure for device selection. The results were then compared with those of a vascular radiologist. Six surgeons agreed on the suitability of endovascular repair in 45% of cases (95% CI, 23.1-68.5%; 9/20 scans; kappa = 0.41 [p = 0.01]) and concurred with the radiologist in eight of these. Individually, agreement ranged from 13 to 16 of the 20 scans, 65-80% between surgeons. The kappa value for agreement between all the surgeons and the radiologist was 0.47 (p = 0.01, moderate agreement). For the individual surgeons, this ranged from 0.3 to 0.6 (p = 0.01). In conclusion, while overall agreement was moderate between the surgeons and the radiologist, it is clear that if surgeons are to assess patients for ruptured EVAR in the future, focused training of surgical trainees is required.

  13. 腹主动脉瘤腔内治疗现状%Endovascular abdominal aortic aneurysm repair

    Institute of Scientific and Technical Information of China (English)

    符伟国; 邵明哲

    2005-01-01

    @@ 1991年,Parodi等[1]发明人工血管内支架(stent graft,SG)并用于临床成功治愈腹主动脉瘤(abdominal aortic aneurysm,AAA),此后腹主动脉瘤腔内治疗(endovascular abdominal aortic aneurysm repair,EVAR)取得迅速发展.由于EVAR避免了传统开腹手术创伤大和出血多的缺点,使高龄或伴有心、肺、肝、肾功能不全的患者获得积极治疗的机会.一般来讲,腔内治疗主要是指肾下型腹主动脉瘤.目前,EVAR特有并发症,如内漏、移位和SG塌陷等已有大量报道,SG结构破损现象亦有报道.但是,随着SG制造技术的不断进步和手术安全性的逐步提高,SG移植术不再局限于治疗高龄或有严重伴发病的患者,它将取代部分传统开腹术,成为AAA的主要治疗方法.

  14. Current management of inguinal false aneurysms

    DEFF Research Database (Denmark)

    Houlind, Kim Christian; Michael Jepsen, Jørn; Saicu, Christian;

    2016-01-01

    from puncture sites after percutaeous intervention. Anticoagulative medication, low patelet counts and severely calcified vessels increase the risk of forming a false aneurysm. Experienced specialists may make the diagnosis from physical examination, but ultrasound imaging is almost always needed...... vessels. endovascular treatment with coils or covered stent grafts have proven useful in infected ilio-femoral false aneurysms. Open surgical repair may be the best treatment in the setting of imminent rupture, massive haematoma and skin necrosis. We present three patient cases treated with open surgery...

  15. Thoracic aorta aneurysm repair in a patient with a solitary kidney: Hybrid Surgery as a bailout procedure

    Directory of Open Access Journals (Sweden)

    Chris Bakoyiannis

    2016-11-01

    Full Text Available Thoracic endovascular aortic repair (TEVAR is an emerging treatment option for thoracic aorta aneurysms (TAA. Endovascular access is a challenge. We present a novel TEVAR-technique in a patient with single kidney and a 6.4cm TAA. Attempting to place a sheath through iliac arteries was unsuccessful. The decision to proceed to hybrid-TEVAR was made. The protection of the solitary kidney was achieved through axillo-femoral bypass, followed by an end-to-side anastomosis between the aorta and a bifurcated graft. Through the graft, a stent was introduced in the thoracic aorta. With the use of contrast material, the right position of the graft was confirmed.

  16. The increasing role of duplex scanning in the follow-up after endovascular repair of abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Pulli R

    2014-04-01

    Full Text Available Raffaele Pulli, Walter Dorigo, Leonidas Azas, Stefano Matticari, Aaron Fargion, Carlo PratesiDepartment of Vascular Surgery, University of Florence, Florence, ItalyAim: To analyze the results of a follow-up program after endovascular repair of abdominal aortic aneurysm (EVAR mainly based on duplex ultrasound (DUS examinations.Materials and methods: The postoperative surveillance program changed over the time. In recent years (2007-2012 we are used to performing a DUS and an angio-CT scan within one month after EVAR, a DUS at 6 and 12 months and every 6 months thereafter (Group 2, 498 interventions. Data were compared with our historical series (2000-2006; Group 1, 345 interventions. Perioperative results were recorded. The long-term results were analysed by Kaplan-Meier curves.Results: The rates of perioperative mortality were 1.1% and 1.2% respectively (P=0.9. The cumulative rates of perioperative complications were 16% and 6.5%, respectively (P=0.001. The rate of reinterventions at 60 months was significantly higher in group 2 than in group 1 (29.1% and 20.1% respectively, P=0.03, log rank 4.6. Also the 5-year rate of endoleak was significantly greater in group 2 than group 1 (43.3% and 34.5% respectively, P<0.001, log rank 13.4; however, the rate of endoleaks requiring a redo procedure was lower in group 2 (35/163, 21.5% than in group 1 (51/108, 47%; P<0.001.Conclusion: Data from our study confirm that a DUS-based follow-up program in patients undergoing EVAR is equally sensitive in identifying endoleaks to the CT scan-based program used in past years.Keywords: duplex ultrasound, contrast-enhanced, endovascular aneurysm repair

  17. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  18. Endovascular stent-graft placement and secondary intervention for abdominal aortic aneurysm in a patient who had a previously inserted iliac stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Kee Chun [Inha University College of Medicine, Incheon (Korea, Republic of)

    2007-04-15

    Endovascular repair of abdominal aortic aneurysm is associated with low morbidity and mortality rates when compared to open surgery, and this can be used in patients who are at a high risk for open surgical repair. Also, secondary intervention is an important for achieving intermediate and long term success of endovascular repair of abdominal aortic aneurysm as this can resolve complications. We report here on endovascular stent-graft placement and a secondary interventional procedure in the abdominal aortic aneurysm of a patient who had a previously inserted iliac stent.

  19. Surgical options for the management of visceral artery aneurysms.

    Science.gov (United States)

    Van Petersen, A; Meerwaldt, R; Geelkerken, R; Zeebregts, C

    2011-06-01

    Visceral artery aneurysm (VAA) is a rare entity but increased use of abdominal imaging has led to an increased prevalence. Rupture is related to a high mortality rate. Open repair, endovascular treatment and laparoscopic techniques have been described as treatment options. In this systematic review we describe the surgical options for treating VAA. A literature search identified articles focussing on the key issues of visceral artery aneurysms and surgical options using the Pubmed and Cochrane databases. Case reports dominate the literature about VAA. Twenty-seven small case series and ten review articles have been published in the last 20 years concerning the surgical options for VAA. The evidence does not exceed level 3. Surgical treatment is dictated by both patient and aneurysm characteristics. Whether VAA should be treated largely depends upon age, gender, presence of hypertension (e.g. in renal aneurysm), aneurysm size and presentation. Aneurysm size and characteristics, anatomical location and presence of collateral circulation dictate the surgical option to be chosen. The mortality and morbidity rates after elective open repair are low. Literature about surgical options for treating VAA remains scarce. Only a few clinical trials have shown the possibilities and results of open surgical repair. In general, there is no consensus on the surgical treatment of VAA and the highest level of evidence is based upon expert opinions.

  20. "Squid-capture" modified in situ stent-graft fenestration technique for aortic arch aneurysm repair.

    Science.gov (United States)

    Hongo, Norio; Miyamoto, Shinji; Shuto, Rieko; Wada, Tomoyuki; Kamei, Noritaka; Sato, Aiko; Matsumoto, Shunro; Kiyosue, Hiro; Mori, Hiromu

    2014-08-01

    An 83-year-old female was found to have an fusiform aneurysm in the aortic arch. She was deemed to be a high surgical risk; therefore, endovascular stent-graft placement followed by revascularization of the brachiocephalic trunk using in situ stent-graft fenestration was considered. However, the safe application of fenestration was deemed difficult due to the tortuosity of the brachiocephalic artery. The patient was successfully treated with the aid of the "squid-capture" technique, which consists of deployment of the stent-graft in a snare wire loop that was advanced from the brachiocephalic artery and fenestration of the stent-graft with the support of the loop. A follow-up exam revealed complete sealing of the aneurysm without any complications. The squid-capture technique allows for the safe and secure puncture of the graft.

  1. Randomized trial comparing the Prolene Hernia System, mesh plug repair and Lichtenstein method for open inguinal hernia repair.

    NARCIS (Netherlands)

    Nienhuijs, S.W.; Oort, I.M. van; Keemers-Gels, M.E.; Strobbe, L.J.; Rosman, C.

    2005-01-01

    BACKGROUND: Most surgeons favour the use of a mesh for open inguinal hernia repair as it has a low recurrence rate. Procedures used most frequently are the Lichtenstein method, mesh plug repair and the Prolene Hernia System. The choice of technique may be influenced by the effects on postoperative p

  2. Flow diversion in vasculitic intracranial aneurysms? Repair of giant complex cavernous carotid aneurysm in polyarteritis nodosa using Pipeline embolization devices: first reported case.

    Science.gov (United States)

    Martinez Santos, Jaime; Kaderali, Zul; Spears, Julian; Rubin, Laurence A; Marotta, Thomas R

    2016-07-01

    Intracranial aneurysms in polyarteritis nodosa (PAN) are exceedingly rare lesions with unpredictable behavior that pose real challenges to microsurgical and endovascular interventions owing to their inflammatory nature. We introduce a safe and effective alternative for treating these aneurysms using Pipeline embolization devices (PEDs). A 20-year-old man presented with diplopia, headaches, chronic abdominal pain, and weight loss. Diagnostic evaluations confirmed PAN, including bilateral giant cavernous carotid aneurysms. Cyclophosphamide and steroids achieved significant and sustained clinical improvement, with a decision to follow the aneurysms serially. Seven years later the left unruptured aneurysm enlarged, causing a sudden severe headache and a cavernous sinus syndrome. Treatment of the symptomatic aneurysm was pursued using flow diversion (PED) and the internal carotid artery was successfully reconstructed with a total of four overlapping PEDs. At 6 months follow-up, complete exclusion of the aneurysm was demonstrated, with symptomatic recovery. This is the first description of using a flow-diverting technique in an inflammatory vasculitis. In this case, PEDs not only attained a definitive closure of the aneurysm but also reconstructed the damaged and fragile arterial segment affected with vasculitis.

  3. Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

    Science.gov (United States)

    Karanikola, Evridiki; Dalainas, Ilias; Karaolanis, Georgios; Zografos, Georgios; Filis, Konstantinos

    2014-01-01

    In the last decade, endovascular aneurysm repair (EVAR) has rapidly developed to be the preferred method for infrarenal abdominal aortic aneurysm repair in patients with suitable anatomy. EVAR offers the advantage of lower perioperative mortality and morbidity but carries the cost of device-related complications such as endoleak, graft migration, graft thrombosis, and structural graft failure. These complications mandate a lifelong surveillance of EVAR patients and their endografts. The purpose of this study is to review and evaluate the safety of color-duplex ultrasound (CDU) as compared with computed tomography (CT), based on the current literature, for post-EVAR surveillance. The post-EVAR follow-up modalities, CDU versus CT, are evaluated questioning three parameters: (1) accuracy of aneurysm size, (2) detection and classification of endoleaks, and (3) detection of stent-graft deformation. Studies comparing CDU with CT scan for investigation of post-EVAR complications have produced mixed results. Further and long-term research is needed to evaluate the efficacy of CDU versus CT, before CDU can be recommended as the primary imaging modality for EVAR surveillance, in place of CT for stable aneurysms. PMID:25317026

  4. Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

    Science.gov (United States)

    Karanikola, Evridiki; Dalainas, Ilias; Karaolanis, Georgios; Zografos, Georgios; Filis, Konstantinos

    2014-09-01

    In the last decade, endovascular aneurysm repair (EVAR) has rapidly developed to be the preferred method for infrarenal abdominal aortic aneurysm repair in patients with suitable anatomy. EVAR offers the advantage of lower perioperative mortality and morbidity but carries the cost of device-related complications such as endoleak, graft migration, graft thrombosis, and structural graft failure. These complications mandate a lifelong surveillance of EVAR patients and their endografts. The purpose of this study is to review and evaluate the safety of color-duplex ultrasound (CDU) as compared with computed tomography (CT), based on the current literature, for post-EVAR surveillance. The post-EVAR follow-up modalities, CDU versus CT, are evaluated questioning three parameters: (1) accuracy of aneurysm size, (2) detection and classification of endoleaks, and (3) detection of stent-graft deformation. Studies comparing CDU with CT scan for investigation of post-EVAR complications have produced mixed results. Further and long-term research is needed to evaluate the efficacy of CDU versus CT, before CDU can be recommended as the primary imaging modality for EVAR surveillance, in place of CT for stable aneurysms.

  5. PCA-induced respiratory depression simulating stroke following endoluminal repair of abdominal aortic aneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Ahmad Javed

    2007-07-01

    Full Text Available Abstract Aim To report a case of severe respiratory depression with PCA fentanyl use simulating stroke in a patient who underwent routine elective endoluminal graft repair for abdominal aortic aneurysm (AAA Case presentation A 78-year-old obese lady underwent routine endoluminal graft repair for AAA that was progressively increasing in size. Following an uneventful operation postoperative analgesia was managed with a patient-controlled analgesia (PCA device with fentanyl. On the morning following operation the patient was found to be unusually drowsy and unresponsive to stimuli. Her GCS level was 11 with plantars upgoing bilaterally. A provisional diagnosis of stroke was made. Urgent transfer to a high-dependency unit (HDU was arranged and she was given ventilatory support with a BiPap device. CT was performed and found to be normal. Arterial blood gas (ABG analysis showed respiratory acidosis with PaCO2 81 mmHg, PaO2 140 mmHg, pH 7.17 and base excess -2 mmol/l. A total dose of 600 mcg of fentanyl was self-administered in the 16 hours following emergence from general anaesthesia. Naloxone was given with good effect. There was an increase in the creatinine level from 90 μmol/L preoperatively to 167 μmol/L on the first postoperative day. The patient remained on BiPap for two days that resulted in marked improvement in gas exchange. Recovery was complete.

  6. Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

    Directory of Open Access Journals (Sweden)

    James Barr

    2016-01-01

    Full Text Available Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications.

  7. Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

    Science.gov (United States)

    Barr, James; Kourliouros, Antonios

    2016-01-01

    Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications. PMID:28018699

  8. Abdominal aortic aneurysm: Treatment options, image visualizations and follow-up procedures

    Institute of Scientific and Technical Information of China (English)

    Zhong-Hua Sun

    2012-01-01

    Abdominal aortic aneurysm is a common vascular disease that affects elderly population.Open surgical repair is regarded as the gold standard technique for treatment of abdominal aortic aneurysm,however,endovaseular aneurysm repair has rapidly expanded since its first introduction in 1990s.As a less invasive technique,endovascular aneurysm repair has been confirmed to be an effective alternative to open surgical repair,especially in patients with co-morbid conditions.Computed tomography (CT) angiography is currently the preferred imaging modality for both preoperative planning and post-operative follow-up.2D CT images are complemented by a number of 3D reconstructions which enhance the diagnostic applications of CT angiography in both planning and follow-up of endovascular repair.CT has the disadvantage of high cummulative radiation dose,of particular concern in younger patients,since patients require regular imaging follow-ups after endovascular repair,thus,exposing patients to repeated radiation exposure for life.There is a trend to change from CT to ultrasound surveillance of endovascular aneurysm repair.Medical image visualizations demonstrate excellent morphological assessment of aneurysm and stent-grafts,but fail to provide hemodynamic changes caused by the complex stent-graft device that is implanted into the aorta.This article reviews the treatment options of abdominal aortic aneurysm,various image visualization tools,and follow-up procedures with use of different modalities including both imaging and computational fluid dynamics methods.Future directions to improve treatment outcomes in the follow-up of endovascular aneurysm repair are outlined.

  9. Editorial Commentary: Arthroscopic Rotator Cuff Repair--Infection Rate After Rotator Cuff Repair With Arthroscopic, Open, and Mini-open Techniques.

    Science.gov (United States)

    Brand, Jefferson C

    2016-03-01

    In "Risk Factors for Infection After Rotator Cuff Repair," B. G. Vopat et al. report a lower rate of postoperative infection with an arthroscopic rotator cuff repair than with an open or mini-open approach. Although there were only 14 infections (infection rate of 0.77%), the reason for the preponderance of male patients, 13 of the 14 infections, needs further research to determine effective preventive strategies.

  10. Late neurological recovery of paraplegia after endovascular repair of an infected thoracic aortic aneurysm

    NARCIS (Netherlands)

    B.M.E. Mees (Barend); F.M.V. Bastos Gonçalves (Frederico); P.J. Koudstaal (Peter Jan); H.J.M. Verhagen (Hence)

    2013-01-01

    textabstractSpinal cord ischemia is a potentially devastating complication after thoracic endovascular aorta repair (TEVAR). Patients with spinal cord ischemia after TEVAR often develop paraplegia, which is considered irreversible, and have significant increased postoperative morbidity and mortality

  11. MRI using ultrasmall superparamagnetic particles of iron oxide in patients under surveillance for abdominal aortic aneurysms to predict rupture or surgical repair: MRI for abdominal aortic aneurysms to predict rupture or surgery—the MA3RS study

    Science.gov (United States)

    McBride, Olivia M B; Berry, Colin; Burns, Paul; Chalmers, Roderick T A; Doyle, Barry; Forsythe, Rachael; Garden, O James; Goodman, Kirsteen; Graham, Catriona; Hoskins, Peter; Holdsworth, Richard; MacGillivray, Thomas J; McKillop, Graham; Murray, Gordon; Oatey, Katherine; Robson, Jennifer M J; Roditi, Giles; Semple, Scott; Stuart, Wesley; van Beek, Edwin J R; Vesey, Alex; Newby, David E

    2015-01-01

    Introduction Population screening for abdominal aortic aneurysms (AAA) halves the associated mortality and has led to the establishment of national screening programmes. Prediction of aneurysm growth and rupture is challenging and currently relies on serial diameter measurements with ultrasound. Recently, a novel MRI-based technique using ultrasmall superparamagnetic particles of iron oxide (USPIO) has demonstrated considerable promise as a method of identifying aneurysm inflammation and expansion. Methods and analysis The MA3RS study is a prospective observational multicentre cohort study of 350 patients with AAA in three centres across Scotland. All participants will undergo MRI with USPIO and aneurysm expansion will be measured over 2 years with CT in addition to standard clinical ultrasound surveillance. The relationship between mural USPIO uptake and subsequent clinical outcomes, including expansion, rupture and repair, will be evaluated and used to determine whether the technique augments standard risk prediction markers. To ensure adequate sensitivity to answer the primary question, we need to observe 130 events (composite of rupture or repair) with an estimated event rate of 41% over 2 years of follow-up. The MA3RS study is currently recruiting and expects to report in 2017. Discussion This is the first study to evaluate the use of USPIO-enhanced MRI to provide additional information to aid risk prediction models in patients with AAA. If successful, this study will lay the foundation for a large randomised controlled trial targeted at applying this technique to determine clinical management. Trial registration number Current Controlled Trials: ISRCTN76413758. PMID:25932334

  12. Deep Vein Thrombosis and True Crural Aneurysm: Misdiagnosis or Causal Relation?

    Science.gov (United States)

    Floros, Nikolaos; Antoniou, Zoi; Papadakis, Marios

    2016-04-01

    True crural artery aneurysm is a rare clinical entity. Crural artery aneurysms are most frequently seen in men in their sixth decade without major cardiopulmonary diseases and are often associated with injury, superinfection, or vasculitis. We report the case of a 44-year-old man with a history of idiopathic deep vein thrombosis (DVT) as the first manifestation of a true crural artery aneurysm. To our knowledge, DVT is very rarely related with true crural artery aneurysms, with only 3 cases reported in the current literature. Open surgical repair is the most common management, with ligation as a second option in emergencies such as rupture. The related literature is discussed. We conclude that crural aneurysms should be considered in differential diagnosis of popliteal DVT in adults. True crural aneurysms need vigilance and a more systematical approach to provide physicians the means to the best medical care.

  13. Abdominal aortic aneurysm repair in patient with a renal allograft: a case report.

    Science.gov (United States)

    Kim, Hyung-Kee; Ryuk, Jong-Pil; Choi, Hyang Hee; Kwon, Sang-Hwy; Huh, Seung

    2009-02-01

    Renal transplant recipients requiring aortic reconstruction due to abdominal aortic aneurysm (AAA) pose a unique clinical problem. The concern during surgery is causing ischemic injury to the renal allograft. A variety of strategies for protection of the renal allograft during AAA intervention have been described including a temporary shunt, cold renal perfusion, extracorporeal bypass, general hypothermia, and endovascular stent-grafting. In addition, some investigators have reported no remarkable complications of the renal allograft without any specific measures. We treated a case of AAA in a patient with a renal allograft using a temporary aortofemoral shunt with good result. Since this technique is safe and effective, it should be considered in similar patients with AAA and previously placed renal allografts.

  14. Endovascular repair of ruptured aneurysm arising from fenestration of the horizontal segment of the anterior cerebral artery: case report.

    Science.gov (United States)

    Yoshida, Masahiro; Ezura, Masayuki; Sasaki, Kazuto; Chonan, Masashi; Mino, Masaki

    2012-01-01

    A 50-year-old man presented with an aneurysm arising from a fenestration of horizontal portion (A(1)) of the anterior cerebral artery manifesting as subarachnoid hemorrhage. Coil embolization was conducted and the aneurysm was occluded easily. Most reported cases of these types of aneurysms underwent direct surgery. Aneurysm arising from the A(1) fenestration is rare, but the present case shows that coil embolization can be an effective treatment modality. Three-dimensional rotational angiography and aneurysmography were helpful to characterize this complicated vascular structure.

  15. In situ repair of a primary Brucella-infected abdominal aortic aneurysm: long-term follow-up.

    Science.gov (United States)

    Goudard, Yvain; Pierret, Charles; de La Villéon, Bruno; Mlynski, Amélie; de Kerangal, Xavier

    2013-02-01

    Infected aortic aneurysms represent 0.85 to 1.3% of aortic aneurysms. Most often, the implicated bacteria species are Salmonella sp., Staphylococcus sp. and Streptococcus sp. Brucella-related infected aortic aneurysms are very rare. Most often, they result from endocarditis or from a local septic focus. Combined treatment by antibiotics and surgery is the standard for infectious aneurysms. In the absence of formal factual data, the surgical treatment is still discussed in the literature, especially since endovascular treatments have been in full expansion. We are reporting the case of a female patient presenting with a Brucella-related infra-renal abdominal aortic aneurysm, without primitive infectious source (area) or identified endocarditis. Surgical treatment with in situ prosthetic replacement and omentoplasty in association with adapted antibiotics allowed a favorable outcome with an excellent result after an 8-year follow up.

  16. Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Juszczak, Maciej T. [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Bratby, Mark J. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Sideso, Ediri [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Anthony, Susan; Tapping, Charles R. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Handa, Ashok; Darby, Christopher R.; Perkins, Jeremy [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Uberoi, Raman [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom)

    2015-08-15

    PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

  17. Endovascular abdominal aortic aneurysm repair: surveillance of endoleak using maximum transverse diameter of aorta on non-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Nagayama, Hiroki; Sueyoshi, Eijun; Sakamoto, Ichiro; Uetani, Masataka [Dept. of Radiology, Nagasaki Univ. School of Medicine, Nagasaki (Japan)], E-mail: sueyo@nagasaki-u.ac.jp

    2012-07-15

    Background. Repeat volumetric analysis of abdominal aortic aneurysm (AAA) after endovascular AAA repair (EVAR) is time-consuming and requires advanced processing, dedicated equipment, and skilled operators. Purpose. To clarify the validity of measuring the maximal short-axis diameter (Dmax) of AAA in follow-up non-enhanced axial CT as a means of detecting substantial endoleaks after EVAR. Material and Methods. CT images were retrospectively reviewed in 47 patients (7 women, 40 men; mean age, 76.2 years) who had no endoleak on initial contrast-enhanced CT after EVAR. Regular follow-up CT studies were performed every 6 months. At each CT study, the Dmax on the CT axial image was measured and compared with that on the last CT (115 data-sets). Contrast-enhanced CT was regarded as the standard of reference to decide the presence or absence of endoleaks. The appearance of endoleak was defined as the end point of this study. Results. Endoleaks were detected in 17 patients during the follow-up period. Mean Dmax changes for 6 months were significant between positive and negative endoleak cases (1.8 {+-} 1.9 vs. -1.1 {+-} 3.0 mm, P < 0.0001). When the Dmax change {<=} 0 mm for 6 months was used as the threshold for negative endoleak, the sensitivity, specificity, positive predictive value, and negative predictive value were 74.5, 82.4, 96.1, and 35.9%, respectively. When Dmax change {<=}-1 mm was used as the threshold, the sensitivity, specificity, PPV, and NPV were 38.8, 100, 100, and 22.1%, respectively. Conclusion. Contrast-enhanced CT is not required for the evaluation of endoleaks when the Dmax decreases by at least 1 mm over 6 months after EVAR.

  18. Chronic pain after open mesh and sutured repair of indirect inguinal hernia in young males

    DEFF Research Database (Denmark)

    Bay-Nielsen, M; Nilsson, E; Nordin, P;

    2004-01-01

    males operated on for an indirect inguinal hernia with a Lichtenstein mesh repair, Shouldice or Marcy (annulorrhaphy) repair. METHODS: This was a postal questionnaire study carried out within the Danish and Swedish Hernia Database Collaboration. Some 2612 patients responded (response rate 80.9 per cent...... it as worse after than before surgery, and 56.6 per cent stated that it interfered with social activities. CONCLUSION: Chronic pain is common after primary inguinal hernia repair in young males, but there is no difference in the pain associated with open mesh and non-mesh repair....

  19. Endoleak detection after endovascular aneurysm repair using unenhanced MRI with flow suppression technique: Feasibility study in comparison with contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kensaku; Saida, Tsukasa; Okamoto, Yoshikazu; Nasu, Katsuhiro; Minami, Manabu [University of Tsukuba, Department of Radiology Faculty of Medicine, Tsukuba, Ibaraki (Japan); Sato, Fujio [University of Tsukuba, Department of Cardiovascular Surgery, Faculty of Medicine, Tsukuba, Ibaraki (Japan); Uchikawa, Yoko [Hitachi General Hospital, Department of Radiology, Hitachi, Ibaraki (Japan); Konishi, Takahiro; Ishiguro, Toshitaka; Hiyama, Takashi [University of Tsukuba Hospital, Department of Radiology, Tsukuba, Ibaraki (Japan); Hoshiai, Sodai [Ibaraki Prefectural Central Hospital, Department of Radiology, Kasama, Ibaraki (Japan)

    2017-01-15

    To evaluate the feasibility of unenhanced motion-sensitized-driven equilibrium (MSDE)-prepared balanced turbo field echo (BTFE) sequences for detecting endoleaks after endovascular aneurysm repair (EVAR). Forty-six patients treated with EVAR for aortic and/or iliac arterial aneurysms underwent contrast-enhanced CT and MSDE-prepared BTFE sequences with and without flow suppression. Two independent observers reviewed these sequences and their subtraction images and assigned confidence levels for detecting endoleaks. Relative contrast values were calculated by dividing signal intensities by those of paraspinal muscles. CT provided the reference standard. CT showed types I and II endoleaks in one and ten patients, respectively. Areas under receiver operating characteristic curves were 0.92 and 0.97 for observers 1 and 2, respectively. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both observers were 91 (10/11), 91(32/35), 91 (42/46), 77 (10/13) and 97 % (32/33), respectively. Relative contrast values of endoleaks and flowing blood significantly decreased by flow suppression on MSDE-prepared BTFE images (P = 0.002 and P < 0.0001 respectively), and were significantly higher than those of the excluded aneurysms on subtraction images (P = 0.003 and P = 0.001, respectively). Unenhanced MSDE-prepared BTFE sequences are feasible for detecting endoleaks. (orig.)

  20. Combined surgical and catheter-based treatment of extensive thoracic aortic aneurysm and aortic valve stenosis

    DEFF Research Database (Denmark)

    De Backer, Ole; Lönn, Lars; Søndergaard, Lars

    2015-01-01

    endovascular aneurysm repair (TEVAR) has changed and extended management options in thoracic aorta disease, including in those patients deemed unfit or unsuitable for open surgery. Accordingly, transcatheter aortic valve replacement (TAVR) is increasingly used to treat patients with symptomatic severe aortic...... valve stenosis (AS) who are considered at high risk for surgical aortic valve replacement. In this report, we describe the combined surgical and catheter-based treatment of an extensive TAA and AS. To our knowledge, this is the first report of hybrid TAA repair combined with TAVR.......An extensive thoracic aortic aneurysm (TAA) is a potentially life-threatening condition and remains a technical challenge to surgeons. Over the past decade, repair of aortic arch aneurysms has been accomplished using both hybrid (open and endovascular) and totally endovascular techniques. Thoracic...

  1. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  2. Tratamento do aneurisma da aorta toracoabdominal com endoprótese ramificada para as artérias viscerais Branched endovascular stent graft for thoracoabdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    André Simi

    2007-03-01

    AATA com endoprótese ramificada é factível. A melhora dos recursos técnicos e da qualidade dos materiais poderá ampliar a indicação desse procedimento como alternativa à cirurgia aberta.We report a case of branched stent graft system for endovascular repair of thoracoabdominal aortic aneurysm (TAAA. A 68-year-old female patient, smoker, hypertensive, with a large TAAA and multiple comorbid conditions that restricted indication for conventional surgery. The aneurysm originated from the descending thoracic aorta, extending until the infrarenal abdominal aorta, involving the emergence of visceral arteries, celiac trunk, superior and renal mesenteric arteries. The TAAA was treated with the endovascular technique using a branched stent graft. This stent graft was customized based on the anatomical characteristics of the aorta and on the position of visceral branches, which were obtained by tomographic angiography, with the aim of excluding the aneurysm and maintaining perfusion of visceral arteries. The procedure was performed under regional and general anesthesia in the surgical room, preceded by cerebrospinal fluid drainage under fluoroscopic guidance. The femoral arteries, which were previously dissected, were used to implement the branched stent graft and for radiological control. Through the stent graft branches, secondary extensions were implanted, with covered stents, to the respective visceral arteries, which were approached via left axillary artery. Total operative time was 14 hours, 4 hours and 30 minutes of fluoroscopy time and 120 mL of iodinated contrast. The patient became hemodynamically unstable after the surgery. Transesophageal echocardiogram showed a type A retrograde dissection of the thoracic aorta, followed by spontaneous thrombosis of the false lumen. Control tomography showed exclusion of the TAAA and patency of the bypasses to visceral branches, with no endoleaks. The patient was discharged on the 13th postoperative day. Branched

  3. True aneurysm of brachial artery.

    Science.gov (United States)

    Hudorović, Narcis; Lovričević, Ivo; Franjić, Dario Bjorn; Brkić, Petar; Tomas, Davor

    2010-10-01

    True upper extremity peripheral artery aneurysms are a rarely encountered arterial disorder. Following computer-tomography angiographic (CT-a) imaging examination, true saccular aneurysm, originating from the left brachial artery was diagnosed in the 77-year-old female without history of trauma. The aneurysm was resected by surgical intervention, and primary repair of the brachial artery was performed by interposition of a part of great saphenous vein harvested from the left groin and creation of two end-to-end anastomoses between interposition graft and previously resected part of brachial artery. No complication was observed during the follow-up. Surgical intervention for upper extremity aneurysms should be initiated without delay. Factors combined with minimal morbidity associated with repair suggest that surgical repair should be performed routinely for true upper extremity arterial aneurysms.

  4. Near-infrared spectroscopy assessed cerebral oxygenation during open abdominal aortic aneurysm repair

    DEFF Research Database (Denmark)

    Sørensen, H.; Nielsen, H. B.; Secher, N H

    2016-01-01

    intend to adjust ventilation according end-tidal CO2 tension (EtCO2) and here evaluated to what extent that strategy maintains frontal lobe oxygenation (ScO2) as determined by near infrared spectroscopy. For 44 patients [5 women, aged 70 (48-83) years] ScO2, mean arterial pressure (MAP), EtCO2...

  5. Idiopathic thoracic aortic aneurysm at pediatric age.

    Science.gov (United States)

    Marín-Manzano, E; González-de-Olano, D; Haurie-Girelli, J; Herráiz-Sarachaga, J I; Bermúdez-Cañete, R; Tamariz-Martel, A; Cuesta-Gimeno, C; Pérez-de-León, J

    2009-03-01

    A 6-year-old-boy presented with epigastric pain and vomiting over 1 year. Chest X-ray and esophagogastric transit showed a mediastinal mass. A chest computerized tomography angiogram demonstrated a descending thoracic aortic aneurysm. Analytical determinations carried out were all negative. The aneurysm was surgically repaired using a Dacron patch. The anatomopathological study described atherosclerotic lesions with calcifications, compatible with an atherosclerotic aneurysm wall. Aneurysms are uncommon in the pediatric population. Usually, no pathogenesis can be determined, and thus, such cases are grouped as idiopathic. Direct repair with or without patch is a therapeutic alternative in pediatric aneurysms and can allow the growth of the aortic circumference.

  6. Laparoscopic vs open incisional hernia repair a randomized clinical trial

    NARCIS (Netherlands)

    H.H. Eker (Hasan); B.M. Hansson; M. Buunen (Mark); I.M.C. Janssen (Ignace); R.E.G.J.M. Pierik (Robert); W.C.J. Hop (Wim); H.J. Bonjer (Jaap); J. Jeekel (Hans); J.F. Lange (Johan)

    2013-01-01

    textabstractImportance: Incisional hernia is the most frequent surgical complication after laparotomy. Up to 30% of all patients undergoing laparotomy develop an incisional hernia. Objective: To compare laparoscopic vs open ventral incisional hernia repairwith regard to postoperative pain and nausea

  7. Outcomes of pediatric inguinal hernia repair with or without opening the external oblique muscle fascia

    Science.gov (United States)

    Nazem, Masoud; Dastgerdi, Mohamad Masoud Heydari; Sirousfard, Motaherh

    2015-01-01

    Background: Considering that complications and outcome of each method of pediatric inguinal hernia repair are one of the determinants for pediatric surgeons for selection of the appropriate surgical technique, we compared the early and late complications of two inguinal repair techniques, with and without opening the external oblique muscle fascia. Materials and Methods: In this double-blind clinical trial study, boy children aged 1-month to 6 years with diagnosed inguinal hernia were included and randomly allocated into two groups for undergoing two types of hernia repair techniques, with and without opening the external oblique muscle fascia. Surgical complications such as fever, scrotal edema and hematoma, and wound infections classified as early complication and recurrence, testis atrophy and sensory impairment of inguinal area classified as late complications. The rates of mentioned early and late complications were compared in the two interventional groups. Results: In this study, 66 patients were selected and allocated to the two interventional groups. The prevalence of early and late complications in two studied groups were not different significantly in two interventional groups (P > 0.05). Operation time was significantly shorter in inguinal repair techniques without opening the external oblique muscle fascia than the other studied technique (P = 0.001). Conclusion: The findings of our study indicated that though early and late complications of the two repair methods were similar, but the time of procedure was shorter in herniotomy without opening the external oblique muscle, which considered the superiority of this method than inguinal hernia repair with opening the external oblique muscle. PMID:26958052

  8. Outcomes of pediatric inguinal hernia repair with or without opening the external oblique muscle fascia

    Directory of Open Access Journals (Sweden)

    Masoud Nazem

    2015-01-01

    Full Text Available Background: Considering that complications and outcome of each method of pediatric inguinal hernia repair are one of the determinants for pediatric surgeons for selection of the appropriate surgical technique, we compared the early and late complications of two inguinal repair techniques, with and without opening the external oblique muscle fascia. Materials and Methods: In this double-blind clinical trial study, boy children aged 1-month to 6 years with diagnosed inguinal hernia were included and randomly allocated into two groups for undergoing two types of hernia repair techniques, with and without opening the external oblique muscle fascia. Surgical complications such as fever, scrotal edema and hematoma, and wound infections classified as early complication and recurrence, testis atrophy and sensory impairment of inguinal area classified as late complications. The rates of mentioned early and late complications were compared in the two interventional groups. Results: In this study, 66 patients were selected and allocated to the two interventional groups. The prevalence of early and late complications in two studied groups were not different significantly in two interventional groups (P > 0.05. Operation time was significantly shorter in inguinal repair techniques without opening the external oblique muscle fascia than the other studied technique (P = 0.001. Conclusion: The findings of our study indicated that though early and late complications of the two repair methods were similar, but the time of procedure was shorter in herniotomy without opening the external oblique muscle, which considered the superiority of this method than inguinal hernia repair with opening the external oblique muscle.

  9. Resultados da cirurgia do aneurisma da aorta abdominal em pacientes jovens Outcomes after surgical repair of abdominal aortic aneurysms in young patients

    Directory of Open Access Journals (Sweden)

    Telmo P. Bonamigo

    2009-06-01

    Full Text Available CONTEXTO: A presença de aneurisma da aorta abdominal (AAA é rara em pacientes jovens. OBJETIVO: Avaliar os resultados da cirurgia do AAA em pacientes com idade BACKGROUND: Abdominal aortic aneurysms (AAA are rare in young patients. OBJECTIVE: To evaluate outcomes after AAA repair in patients aged < 50 years. METHODS: Between June 1979 and January 2008, 946 patients underwent elective repair for an infrarenal AAA performed by the first author. Of these, 13 patients (1.4% were < 50 years old at surgery. Demographic characteristics and surgical data were analyzed, as well as early and late outcomes after surgical intervention. RESULTS: Mean age was 46±3.4 years (ranging from 43 to 50 years. Most patients were men (76.9%, hypertensive (76.9% and smokers (61.5%. Perioperative morbidity and mortality rates were low (15.4% and 0%, respectively; one patient had respiratory infection and another patient had unstable angina. Median follow-up was 85.5 months, and two patients died due to ischemic cardiopathy and cerebrovascular accident during the follow-up period. CONCLUSION: AAA repair in young patients is a safe procedure, with good long-term results. In our study, there were no perioperative deaths, and a good long-term survival was observed.

  10. Aortic graft infection and mycotic aneurysm with Streptococcus equi zooepidemicus: two cases with favorable outcome of antibiotic treatment.

    Science.gov (United States)

    Altreuther, Martin; Lange, Conrad; Myhre, Hans Olav; Hannula, Raisa

    2013-02-01

    Infections with Streptococcus equi zooepidemicus are rare and are associated with contact with animals or animal products. There are very few reports about infected vascular grafts or aneurysms with this etiology. We present two patients. The first is a 77-year-old man with an infected bifurcated graft four years after an open operation for an abdominal aortic aneurysm (AAA). The second is a 72-year-old man with a symptomatic mycotic AAA, treated with endovascular aneurysm repair. Both received prolonged treatment with bactericidal antibiotics and responded well. Follow-up time at present is 5.5 years for the first, and 4.5 years for the second, patient.

  11. Endovascular repair of an aorto-iliac aneurysm succeeded by kidney transplantation Tratamento endovascular de aneurisma aorto-ilíaco sucedido por transplante renal

    Directory of Open Access Journals (Sweden)

    Marcelo Bellini Dalio

    2010-09-01

    Full Text Available We present the case of aorto-iliac aneurysm in a patient with chronic renal failure requiring dialysis who were treated with an endovascular stent graft and, later on, submitted to kidney transplantation. A 53-year-old male with renal failure requiring dialysis presented with an asymptomatic abdominal aorto-iliac aneurysm measuring 5.0cm of diameter. He was treated with endovascular repair technique, being used an endoprosthesis Excluder®. After four months, he was successfully submitted to kidney transplantation (dead donor, with anastomosis of the graft renal artery in the external iliac artery distal to the endoprosthesis. The magnetic resonance imaging, carried out 30 days after the procedure, showed a good positioning of the endoprosthesis and adequate perfusion of the renal graft. In the follow-up, the patient presented improvement of nitrogenous waste, good positioning of the endoprosthesis without migration or endoleak. The endovascular repair of aorto-iliac aneurysm in a patient with end-stage renal failure under hemodialysis treatment showed to be feasible, safe and efficient, as it did not prevent the success of the posterior kidney transplantation.Apresentamos o caso de aneurisma aortoilíaco em um paciente com insuficiência renal crônica dialítica tratado com uma endoprótese vascular, sendo, após, submetido a transplante renal. Um homem de 53 anos com insuficiência renal dialítica apresentava um aneurisma abdominal aortoilíaco assintomático com 5,0cm de diâmetro. Foi tratado com técnica endovascular com uma endoprótese Excluderâ. Após quatro meses, foi submetido a transplante renal (doador cadáver com sucesso, com anastomose da artéria renal do enxerto na artéria ilíaca externa distal à endoprótese. A ressonância magnética 30 dias após o procedimento mostrou a endoprótese bem posicionada e o enxerto renal bem perfundido. No seguimento, o paciente evoluiu com melhora das escórias nitrogenadas, bom

  12. Treatment of abdominal aortic aneurysm in nine countries 2005-2009: a vascunet report

    DEFF Research Database (Denmark)

    Mani, K; Lees, T; Beiles, B

    2011-01-01

    To study contemporary treatment and outcome of abdominal aortic aneurysm (AAA) repair in nine countries.......To study contemporary treatment and outcome of abdominal aortic aneurysm (AAA) repair in nine countries....

  13. Intrapericardial migration of dislodged sternal struts as late complication of open pectus excavatum repairs

    Directory of Open Access Journals (Sweden)

    Haverich Axel

    2011-03-01

    Full Text Available Abstract We present a case of sternal steel strut dislodgement and migration in a patient undergoing Ravitch repair for pectus excavatum (PE 37 years ago. Broken struts perforated the right ventricle and right ventricular outflow tract (RVOT and additionally migrated into the left upper lobar bronchus. Dislodged sternal struts represent rare complications after surgical repair of patients suffering from pectus excavatum. Reviewing the literature, only five cases of intrapericardial migration of dislodged sternal struts or wires have been reported so far. In our case, the first strut was removed from the airways through a left antero-lateral thoracotomy. Using cardiopulmonary bypass, a second strut was removed via ventriculotomy. These life-threatening sequelae underscore the importance of postoperative follow-up and early removal of osteosynthetic materials used in open PE repair. Accurate preoperative localization of migrated materials and availability of CPB support are crucial for successful surgical removal. Introduction The migration of dislodged sternal steel struts or wires into the pericardium and cardiac cavities is a rare but life-threatening complication of open pectus excavatum (PE repair 1. Removal of these materials poses a challenge for cardiothoracic surgeons. Herein, the authors report a case of migration of dislodged steel struts through the right ventricle and right ventricular outflow tract (RVOT into the left upper lobar bronchus in a patient who underwent Ravitch repair 37 years ago.

  14. Evaluation of acute kidney injury as defined by the risk, injury,failure, loss, and end-stage criteria in critically ill patients undergoing abdominal aortic aneurysm repair

    Institute of Scientific and Technical Information of China (English)

    YUE Jia-ning; LUO Zhe; GUO Da-qiao; XU Xin; CHEN Bin; JIANG Jun-hao; YANG Jue

    2013-01-01

    Background Acute kidney injury (AKI) is considered as a common and significant complication following abdominal aortic aneurysm (AAA) repair.This study aimed to assess the associated risk factors of AKI in the critically ill patients undergoing AAA repair and to evaluate the appropriate AKI management in the specific population.Methods We retrospectively examined data from all critically ill patients undergoing AAA repairs at our institution from April 2007 to March 2012.Multivariable analysis was used to identify factors associated with postoperative AKI,which was defined by risk,injury,failure,loss and end-stage (RIFLE) kidney disease criteria.The goal-directed hemodynamic optimization (maintenance of optimal hemodynamics and neutral or negative fluid balance) and renal outcomes were also reviewed.Results Of the 71 patients enrolled,32 (45.1%) developed AKI,with 30 (93.8%) cases diagnosed on admission to surgical intensive care unit (SICU).Risk factors for AKI were ruptured AAA (odds ratio (OR)=5.846,95% confidence interval (Cl):1.346-25.390),intraoperative hypotension (OR=6.008,95% CI:1.176 to 30.683),and perioperative blood transfusion (OR=4.611,95% CI:1.307-16.276).Goal-directed hemodynamic optimization resulted in 75.0% complete and 18.8% partial renal recovery.Overall in-hospital mortality was 2.8% AKI was associated with significantly increased length of stay ((136.9±24.5) hours vs.(70.4±11.3) hours)in Surgical Intensive Care Unit.Conclusions Critically ill patients undergoing AAA repair have a high incidence of AKI,which can be early recognized by RIFLE criteria.Rupture,hypotension,and blood transfusion are the significant associated risk factors.Application of goal-directed hemodynamic optimization in this cohort appeared to be effective in improving renal outcome.

  15. Mycotic aneurysm in a turtle hunter: brief review and a case report

    Directory of Open Access Journals (Sweden)

    Harsha Moole

    2015-06-01

    Full Text Available Salmonella-associated mycotic aneurysm is a rare, but dreaded, complication of salmonellosis. Immunocompromised and elderly populations are more susceptible to develop this extra-intestinal complication. Salmonella is spread via fecal–oral and vehicle-borne routes. Reptiles, especially small pet turtles, have been linked with an increased risk of Salmonella infection. Diagnosis of mycotic aneurysm is a challenge due to atypical presentations. Recently, widespread use of CT scan imaging to evaluate for unexplained abdominal pain and sepsis has led to early identification of mycotic aneurysms. Antibiotic therapy and surgical intervention are the cornerstones of management. Open surgery has been the gold standard of treatment but is associated with increased morbidity and mortality. A relatively new alternative to open surgery is endovascular aneurysm repair (EVAR. It is comparatively less invasive and is associated with reduced early morbidity and mortality in the setting of mycotic aneurysm. However, there is a risk of late infection. Here, we present a patient with Salmonella mycotic aneurysm initially treated conservatively with antibiotic therapy who later underwent successful interval EVAR with no complications to date. Also included is a brief review of Salmonella-associated mycotic aneurysms.

  16. Arthroscopic vs mini-open rotator cuff repair. A quality of life impairment study

    Science.gov (United States)

    Osti, Leonardo; Papalia, Rocco; Paganelli, Massimo; Denaro, Enzo

    2009-01-01

    We compared the clinical and quality of life related outcome of rotator cuff repair performed using either a mini-open or an arthroscopic technique for rotator cuff tears of less than 3 cm. The records of 64 patients who underwent rotator cuff repair between September 2003 and September 2005 were evaluated. Thirty-two patients underwent a mini-open rotator cuff repair, and 32 patients underwent an arthroscopic rotator cuff repair. The mean follow-up period was 31 months in the mini-open group and 30.6 months in the arthroscopic group (P > 0.05). The UCLA rating system, range of motion examination and the self-administered SF-36 used for postoperative evaluation showed a statistically significant improvement from the preoperative to the final score for both groups (P  0.05). This study suggests that there is no difference in terms of subjective and objective outcomes between the two surgical procedures studied if patients have rotator cuff tears of less than 3 cm. PMID:19424692

  17. Compartment Syndrome following Open Femoral Fracture with an Isolated Femoral Vein Injury Treated with Acute Repair

    Directory of Open Access Journals (Sweden)

    David Walmsley

    2014-01-01

    Full Text Available Acute compartment syndrome is a surgical emergency and its diagnosis is more difficult in obtunded or insensate patients. We present the case of a 34-year-old woman who sustained a Gustilo-Anderson grade III open midshaft femur fracture with an isolated femoral vein injury treated with direct repair. She developed lower leg compartment syndrome at 48 hours postoperatively, necessitating fasciotomies. She was subsequently found to have a DVT in her femoral vein at the level of the repair and was started on therapeutic anticoagulation. This case highlights the importance of recognition of isolated venous injuries in a trauma setting as a risk factor for developing compartment syndrome.

  18. Comparison of neonatal tolerance to thoracoscopic and open repair of esophageal atresia with tracheoesophageal fistula

    Institute of Scientific and Technical Information of China (English)

    MA Li; LIU Yong-zhe; MA Ya-qun; ZHANG Sheng-suo; PAN Ning-ling

    2012-01-01

    Background Advances in minimally invasive surgical techniques and neonatal intensive care for neonates have allowed for repair of the neonatal esophageal atresia with tracheoesophageal fistula (EA/TEF) to be approached endoscopically.However,thoracoscopic surgery in children is still performed in only a few centers throughout the world.The aim of this study was to compare the neonatal tolerance to the thoracoscopic repair (TR) and the open repair (OR)and also to discuss anesthetic management in thoracoscopic procedure.Methods We performed a prospective study enrolling newborns diagnosed with EA with distal TEF (type C) receiving the repair surgery between June 2009 and January 2012 in our institution.Data collected included the newborns' gestational age and weight at the time of the operation,operative time,parameters of intraoperative mechanical ventilation,oxygenation,end-tidal carbon dioxide (ETCO2),and analysis of blood gases.Time to extubation and length of stay were also recorded.Results Intravenous induction with muscle paralysis followed by pressure-control ventilation and tracheal intubation regardless of the position of the fistula can be performed uneventfully in EA/TEF newborns with no additional airway anomalies and large,pericarinal fistulas in our experiences.The thoracoscopic approach appeared to take longer than the open approach.During the procedure of repair,hypercarbia and acidosis developed immediately 1 hour after pneumothorax in both groups.CO2 insufflation did have additional influence on the respiratory function of the newborns in the TR group; values of PaCO2 and ETCO2 were higher in the TR group but the difference did not reach statistical significance.By the end of the procedure,values of PaCO2 and ETCO2 returned to the baseline levels while pH did not,but all parameters made no difference in the two groups.Besides,time to extubation was shorter in the TR group.Conclusions Thoracoscopic repair of EA/TEF is comparable to the open repair

  19. Long-term outcome and structural integrity following open repair of massive rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Christoph Bartl

    2012-01-01

    Full Text Available Background: Surgical repair of massive rotator cuff tears is associated with less favorable clinical results and a higher retear rate than repair of smaller tears, which is attributed to irreversible degenerative changes of the musculotendinous unit. Materials and Methods: During the study period, 25 consecutive patients with a massive rotator cuff tear were enrolled in the study and the tears were repaired with an open suture anchor repair technique. Preoperative and postoperative clinical assessments were performed with the Constant score, the simple shoulder test (SST and a pain visual analog scale (VAS. At the final follow-up, rotator cuff strength measurement was evaluated and assessment of tendon integrity, fatty degeneration and muscle atrophy was done using a standardized magnetic resonance imaging protocol. Results: The mean follow-up period was 70 months. The mean constant score improved significantly from 42.3 to 73.1 points at the final follow-up. Both the SST and the pain VAS improved significantly from 5.3 to 10.2 points and from 6.3 to 2.1, respectively. The overall retear rate was 44% after 6 years. Patients with an intact repair had better shoulder scores and rotator cuff strength than those with a failed repair, and also the retear group showed a significant clinical improvement (each P<0.05. Rotator cuff strength in all testing positions was significantly reduced for the operated compared to the contralateral shoulder. Muscle atrophy and fatty infiltration of the rotator cuff muscles did not recover in intact repairs, whereas both parameters progressed in retorn cuffs. Conclusions: Open repair of massive rotator tears achieved high patient satisfaction and a good clinical outcome at the long-term follow-up despite a high retear rate. Also, shoulders with retorn cuffs were significantly improved by the procedure. Muscle atrophy and fatty muscle degeneration could not be reversed after repair and rotator cuff strength still did

  20. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2012-02-01

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  1. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2010-11-11

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  2. OPEN INGUINAL HERNIA REPAIR BY MOSQUITO NET MESH: A FIVE YEARS RETROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Anil

    2014-08-01

    Full Text Available : In inguinal hernia tension free hernioplasty using polypropylene mesh by Lichenstein and Schulman’s method is accepted all over the world. But cost of the mesh is a major contributor to the cost of repair in rural India. A retrospective study of 105 Inguinal hernia operated patients from 1st March 2007 to 30th October 2011 was undertaken to evaluate efficacy and cost benefit of Mosquito Net Mesh (MNM as against conventional mesh repair. All patients were operated under spinal anaesthesia. The ETO sterilized MNM of size 7.5cm by 13cm was used for repair. The incidence of complications, recurrence and cost benefit was investigated after a mean follow up of 37 months. The rate of seroma formation (n=0, hematoma formation (n=0, superficial infection in the form of erythema (n=3, serous discharge after stitch removal (n=7, chronic pain (n=4 and recurrence (n=2 were low. The cost benefit was 40% - 50% of the total cost of the repair by using MNM. ETO sterilized MNM forms a cheap, safe and efficient alternative to the conventional and costly polypropylene mesh in open tension free repair of inguinal hernia in adults.

  3. [Late paraparesis as a postoperative complication in a patient undergoing the repair of a double aortic aneurysm].

    Science.gov (United States)

    Bonome González, C; Alvarez Refojo, F; Fernández Carballal, F; Rodríguez Alvarez, R

    1993-01-01

    We report a case of a fifty-seven (57)-years old man undergoing elective surgery of a thoracoabdominal and aortoiliac aneurysm in a single surgical time. The patients is operated undergoing general anesthetic combined with thoracic epidural blockade, and it was done two aortic cross-clamping: one to five cm of the aortic arch and the other to the infrarenal level. The most important intraoperative complications were during the thoracic aortic cross-clamping and the most important postoperative complication was related 48 hours later, to paraparesis after a hypotension episode what improved with rehabilitation treatment.

  4. Laparo- and thoracoscopic aortic aneurysm neck optimization and treatment of potential endoleaks type IA and II in a porcine model

    DEFF Research Database (Denmark)

    Kloster, Brian Ozeraitis; Lund, Lars; Lindholt, Jes S.

    2016-01-01

    Background: Endovascular repair of aortic aneurysms has a higher incidence of late complications, and open conversion (OC) associated with high mortality may be required. As alternatives to OCs, we propose minimal invasive laparo-/thoracoscopic approaches, either to control endoleaks after endova...

  5. Laparo- and thoracoscopic aortic aneurysm neck optimization and treatment of potential endoleaks type IA and II in a porcine model

    DEFF Research Database (Denmark)

    Kloster, Brian Ozeraitis; Lund, Lars; Lindholt, Jes S

    2016-01-01

    BACKGROUND: Endovascular repair of aortic aneurysms has a higher incidence of late complications, and open conversion (OC) associated with high mortality may be required. As alternatives to OCs, we propose minimal invasive laparo-/thoracoscopic approaches, either to control endoleaks after endova...

  6. Grade 3C open femur fractures with vascular repair in adults.

    Science.gov (United States)

    Balci, Halil I; Saglam, Yavuz; Tunali, Onur; Akgul, Turgut; Aksoy, Murat; Dikici, Fatih

    2015-06-01

    Grade 3C open femur fractures are challenging injuries with higher rates of complications. This is a retrospective review of grade 3C open femur fractures with vascular repair between 2002 and 2012. Outcomes included initial MESS score, additional injuries, duration of operation, complications, secondary operations or amputations, and social life implications. Thirty-one of 39 total patients were selected for revascularization and fracture fixation based on soft tissue injury and MESS score. The intra-operative approach included temporary arterial shunt replacement, orthopedic fixation, arterial reconstruction venous and/or nerve repair and routine fasciotomies. An external fixation and reverse saphenous vein graft was used in a majority of the patients (respectively; 93.5%, 90.3%). The mean follow up was 5.4 years (range 2.2-10). The decision to amputate versus salvage should be left up to patients and their care teams after discussing options and future possibilities rather than using a scoring system.

  7. Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

    Energy Technology Data Exchange (ETDEWEB)

    Dudeck, O., E-mail: oliver.dudeck@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Schnapauff, D. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Herzog, L.; Löwenthal, D.; Bulla, K.; Bulla, B. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Halloul, Z.; Meyer, F. [University of Magdeburg, Department of General, Visceral and Vascular Surgery (Germany); Pech, M. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Gebauer, B. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Ricke, J. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany)

    2015-02-15

    PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

  8. Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.

    Science.gov (United States)

    Illuminati, Giulio; Pacilè, Maria Antonietta; Palumbo, Piergaspare; Salvatori, Filippo Maria; Vietri, Francesco

    2013-01-01

    False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.

  9. Endovascular treatment of ruptured abdominal aortic aneurysm with aortocaval fistula based on aortic and inferior vena cava stent-graft placement.

    Science.gov (United States)

    Silveira, Pierre Galvagni; Cunha, Josué Rafael Ferreira; Lima, Guilherme Baumgardt Barbosa; Franklin, Rafael Narciso; Bortoluzzi, Cristiano Torres; Galego, Gilberto do Nascimento

    2014-11-01

    A ruptured abdominal aortic aneurysm (RAAA), complicated by an aortocaval fistula (ACF), is usually associated with high morbidity and mortality during open operative repair. We report a case of endovascular treatment of an RAAA with ACF. After accessing both common femoral arteries, a bifurcated aortic stent graft was placed. Subsequently, we accessed the fistula from the right femoral vein and a cava vein angiography showed a persistent massive flow from the cava to the excluded aneurysm sac. We proceeded by covering the fistula with an Excluder aortic stent-graft cuff to prevent pressurization of the aneurysm sac and secondary endoleaks. This procedure is feasible and may reduce the chances of posterior endoleaks.

  10. A meta-analysis of surgical morbidity and recurrence after laparoscopic and open repair of primary unilateral inguinal hernia.

    LENUS (Irish Health Repository)

    O'Reilly, Elma A

    2012-05-01

    Laparoscopic inguinal hernia repair (LIHR), using a transabdominal preperitoneal (TAPP) or totally extraperitoneal (TEP) technique, is an alternative to conventional open inguinal hernia repair (OIHR). A consensus on outcomes of LIHR when compared with OIHR for primary, unilateral, inguinal hernia has not been reached.

  11. Surgical repair of left-sided cervical aortic arch aneurysm%左颈位主动脉弓动脉瘤的外科治疗

    Institute of Scientific and Technical Information of China (English)

    郑铁; 朱俊明; 孙立忠; 钟永亮; 齐瑞东; 程力剑; 葛翼鹏; 陈雷; 刘巍; 里程楠; 邢晓燕

    2016-01-01

    目的:总结颈位主动脉弓(cervical aortic arch,CAA)动脉瘤的外科治疗方法及术后早中期效果。方法2010年1月至2014年12月,收治22例CAA动脉瘤患者,均为左位CAA。其中男6例,女16例,年龄(34.09±13.14)岁。术前合并主动脉假性狭窄9例,高血压3例,主动脉瓣反流、Stanford B型主动脉夹层、大脑中动脉瘤各1例。所有患者均采用人工血管替换术行主动脉弓重建。4例(4/22,18.18%)经胸骨正中切口,中度低温停循环、选择性顺行脑灌注下手术,其中同期行主动脉瓣置换术1例;18例(18/22,81.82%)经左后外侧第4肋间切口手术,其中10例体外循环辅助下实施手术,8例直接阻断下手术。结果全组平均呼吸机辅助(13.05±4.73) h,ICU停留(19.14±8.08) h。术后二次开胸止血1例,切口延迟愈合1例,一过性肝功能不全1例。无院内死亡。术后19例随访平均34.73个月,失访3例。随访期间无死亡。结论 CAA动脉瘤患者应积极手术治疗。根据CAA动脉瘤的位置、类型以及合并的其他近端心血管疾病,选择个体化的手术切口、辅助技术及手术方法,一期行主动脉弓重建手术治疗CAA动脉瘤可获得满意的临床效果。%Objective To summarize our experience of surgical repair for cervical aortic arch(CAA) aneurysm and eval-uate early and midterm results of these patients.Methods From January 2010 to December 2014, 22 patients with left-sided CAA aneurysm admitted in our center.There were 6 male and 16 female patients with a mean age of(34.09 ±13.14) years. Comorbidities included pseudocoarctation in 9 patients, hypertension in 4 patients, and aortic valve insufficiency, Stanford type B aortic dissection and middle cerebral artery aneurysm each had 1 patient.All of the patients underwent surgical aortic arch re-construction using artificial graft replacement.Among them, 4(4/22, 18.18%) were

  12. A STUDY OF POSTOPERATIVE COMPLICATIONS FOLLOWING OPEN MESH INGUINAL HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Abdul Kalam

    2016-09-01

    Full Text Available BACKGROUND Inguinal hernia is the most common type of hernia. Inguinal region consists of deep inguinal ring, inguinal canal and superficial inguinal ring, which make the region weak and susceptible to hernia. 65% of inguinal hernias are indirect hernias and 35% direct hernias. Hernioplasty is the strengthening of posterior wall of inguinal canal. It can be done either with the help of mesh repair or darning. Hernioplasty is indicated in recurrent hernia cases, inguinal hernia with weak abdominal muscle tone where mesh plasty is preferred and inguinal hernia with good muscle tone where darning can be done. In mesh repair, posterior wall (Lichtenstein repair of inguinal canal is strengthened by a Prolene or Marlex mesh. Over time, fibroblasts and capillaries grow over the mesh converting it into a thick sheath strengthening the posterior wall. Complications which can be encountered postsurgery are pain, bleeding, urinary retention, scrotal swelling, abdominal distension, seroma and wound infections, chronic pain, keloid and testicular atrophy. MATERIALS AND METHODS  The study was conducted in the Department of General Surgery, Travancore Medical College, Kollam.  The study was done from January 2015 to January 2016.  One hundred cases were identified and were chosen for the study. INCLUSION CRITERIA 1. Inguinal hernia cases treated by open mesh repair. EXCLUSION CRITERIA 1. Other types of inguinal hernia repair. RESULTS All the cases studied belonged to male sex. In our study, age group twenty to forty years amounted to sixty one cases followed by age group forty to sixty years, which amounted to twenty eight cases. Age group zero to twenty years amounted to six cases and age group more than sixty years amounted to five cases. In the study group, seventy two cases were indirect inguinal hernias and twenty eight cases were direct inguinal hernias. Based on the complications encountered, pain at the site was the commonest complaint, which

  13. 继发性腹主动脉瘤肠瘘的诊治分析%Treatment of secondary aortoenteric fistula after endovascular repair of abdominal aortic aneu-rysm

    Institute of Scientific and Technical Information of China (English)

    殷恒讳; 王冕; 李梓伦; 常光其; 王深明

    2016-01-01

    目的:总结继发性腹主动脉瘤肠瘘的诊治经验,提高治疗效果。方法回顾性分析本院2000年1月至2014年12月接诊的6例腹主动脉瘤开放及腔内修复术后继发肠瘘患者的资料。2例初次手术方式为腹主动脉瘤切除+人工血管置换,4例为腹主动脉瘤腔内修复术。本次均以反复发热就诊,发热距初次手术中位时间11个月(1~27个月),2例伴有“预兆性消化道出血”。再次手术前确诊3例,其中2例放弃治疗。4例患者经充分准备后施行腋动脉-双侧股动脉人工血管旁路、移植物取出及肠修补,其中1例伴有主动脉膀胱瘘的患者同时行膀胱修补。结果肠瘘位于十二指肠水平段2例,空肠上中段4例。4例接受再次手术的患者均痊愈出院,随访3~48个月,1例人工血管旁路闭塞但无下肢严重缺血,无其他严重并发症。结论继发性腹主动脉瘤肠瘘是腹主动脉瘤术后罕见的严重并发症,经充分的抗炎准备后建立解剖外旁路并及时移除植入物是有效的治疗手段。%Objective To summarize our experience in the treatment of secondary aortoenteric fistula (AEF) after endovascular repair of abdominal aortic aneurysm. Methods The data of six patients with secondary AEF enrolled in our hospital from January 2000 to December 2014 were retrospectively analyzed. The male to female ratio was 5∶1, with an average age of (66.7±6.7) years (58 to 77 years). Four patients had once received endovascular aorta repair (EVAR), while 2 received open surgery, for abdominal aortic aneurysms. The chief complaint was repeated fever for 1 to 27 months after previous operation. Only three patients were accurately diagnosed as secondary AEF for "herald hemorrhage" or signs of "graft invasion of the intestine"on CT scan. Other 3 patients were diagnosed as prosthesis infection on admission, of whom two patients refused re-operation. In total 4 patients received extra

  14. A Possible Regression Equation for Predicting Visual Outcomes after Surgical Repair of Open Globe Injuries

    Directory of Open Access Journals (Sweden)

    Huseyin Gursoy

    2017-01-01

    Full Text Available Background. To analyze the effects of factors other than the ocular trauma score parameters on visual outcomes in open globe injuries. Methods. Open globe injuries primarily repaired in our hospital were reviewed. The number of surgeries, performance of pars plana vitrectomy (PPV, lens status, affected tissues (corneal, scleral, or corneoscleral, intravitreal hemorrhage, intraocular foreign body, glaucoma, anterior segment inflammation, loss of iris tissue, cutting of any prolapsed vitreous in the primary surgery, penetrating injury, and the time interval between the trauma and repair were the thirteen variables evaluated using linear regression analysis. Results. In total, 131 eyes with a mean follow-up of 16.1±4.7 (12–36 months and a mean age of 33.8±22.2 (4–88 years were included. The regression coefficients were 0.502, 0.960, 0.831, −0.385, and −0.506 for the performance of PPV, aphakia after the initial trauma, loss of iris tissue, penetrating injury, and cutting of any prolapsed vitreous in the primary surgery, respectively (P<0.05 for these variables. Conclusions. The performance of PPV, aphakia after the initial trauma, and loss of iris tissue were associated with poor visual outcomes, whereas cutting any prolapsed vitreous in the primary repair and penetrating-type injury were associated with better visual outcomes.

  15. DESARDA’S NO MESH REPAIR VERSUS LICHTENSTEIN’S OPEN MESH REPAIR OF INGUINAL HERNIA: A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Zaheer

    2015-09-01

    Full Text Available BACKGROUND : The tissue - based techniques are still acceptable for primary inguinal hernia repair according to the European Hernia Society guidelines. Desarda’s no mesh technique, introduced in 2001, is a hernia repair method using an undetached strip of external oblique Apo neurosis . This study compared outcomes after hernia repair with Desarda (D and mesh - based Lichtenstein (L techniques. METHODS : A total of 100 patients were randomly assigned to the D or L group (50 each. The primary outcomes measured were post - operative pain ( D ay1 and day 7, mean hospital stay (in days, return to basic activity (in days and recurrence. RESULTS : During the follow - up, no recurrences were observed in each group (p = 1.000. Average duration of the Desarda’s repair was 65.64 minutes, while the Lichtenstein repair lasted for 65.76 minutes. Mean VAS on 1 st post - operative day was significantly less in Desarda’s repair (2.86 than Lichenstein’s repair (3.50, (p=0.0004. Mean hospital stay was less in Desarda’s repair (2.58 days versus Lichtenstein’s repair (3.90 days p=0.0001. Return to basic physical activity was earlier in Desarda’s repair (7.04 days than Lichenstein’s repair (11.30 days, (p=<0.0001. However there was no recurrence in either group in 18 months follow up. CONCLUSIONS : The Desarda’s and Lichtenstein’s methods of primary inguinal hernia repair do not differ in the means of procedure complexity, surgery time and complication profile. However the return to basic physical activity was earlier in Desarda’s repair. Desarda’s no mesh repair is equally safe and more cost effective than Lichtenstein’s repair. The technique may potentially increase the number of tissue - based methods a vailable for treating inguinal hernias.

  16. Follow-up of endovascular aortic aneurysm repair:Preliminary validation of digital tomosynthesis and contrast enhanced ultrasound in detection of medium- to long-term complications

    Institute of Scientific and Technical Information of China (English)

    Maria Antonietta Mazzei; Susanna Guerrini; Francesco Giuseppe Mazzei; Nevada Cioffi Squitieri; Dario Notaro; Gianmarco de Donato; Giuseppe Galzerano; Palmino Sacco; Francesco Setacci; Luca Volterrani; Carlo Setacci

    2016-01-01

    AIM: To validate the feasibility of digital tomosynthesis of the abdomen(DTA) combined with contrast enhanced ultrasound(CEUS) in assessing complications after endovascular aortic aneurysm repair(EVAR) by using computed tomography angiography(CTA) as the gold standard.METHODS: For this prospective study we enrolled 163 patients(123 men; mean age, 65.7 years) referred for CTA for EVAR follow-up. CTA, DTA and CEUS were performed at 1 and 12 mo in all patients, with a maximum time interval of 2 d.RESULTS: Among 163 patients 33 presented complications at CTA. DTA and CTA correlated for the presence of complications in 32/33(96.96%) patients and for the absence of complications in 127/130(97.69%) patients; the sensitivity, specificity, positive predictive value(PPV), negative predictive value(NPV) and accuracy of DTA were 97%, 98%, 91%, 99%, and 98%, respectively. CEUS and CTA correlated for the presence of complications in 19/33(57.57%) patients and for the absence of complications in 129/130(99.23%) patients; the sensitivity, specificity, PPV, NPV and accuracy of CEUS were 58%, 99%, 95%, 90%, and 91%, respectively. Sensitivity, specificity and accuracy of combining DTA and CEUS together in detecting EVAR complications were 77%, 98% and 95%, respectively.CONCLUSION: Combining DTA and CEUS in EVAR follow-up has the potential to limit the use of CTA only in doubtful cases.

  17. Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Foerth, Monika; Treitl, Karla Maria; Treitl, Marcus [Ludwig Maximilians University of Munich, Institute for Clinical Radiology, Munich (Germany); Seidenbusch, Michael C. [Ludwig Maximilians University of Munich, Institute for Clinical Radiology, Munich (Germany); Clinical Centre of the Ludwig Maximilian University of Munich, Institute for Clinical Radiology, Munich (Germany); Sadeghi-Azandaryani, Mojtaba [Clinical Centre of the County of Erding, Department of Vascular Surgery, Erding (Germany); Lechel, Ursula [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany)

    2015-09-15

    Radiation exposure of patients during endovascular aneurysm repair (EVAR) procedures ranks in the upper sector of medical exposure. Thus, estimation of radiation doses achieved during EVAR is of great importance. Organ doses (OD) and effective doses (ED) administered to 17 patients receiving EVAR were determined (1) from the exposure parameters by performing Monte Carlo simulations in mathematical phantoms and (2) by measurements with thermoluminescent dosimeters in a physical anthropomorphic phantom. The mean fluoroscopy time was 26 min, the mean dose area product was 24995 cGy cm2. The mean ED was 34.8 mSv, ODs up to 626 mSv were found. Whereas digital subtraction angiographies (DSA) and fluoroscopies each contributed about 50 % to the cumulative ED, the ED rates of DSAs were found to be ten times higher than those of fluoroscopies. Doubling of the field size caused an ED rate enhancement up to a factor of 3. EVAR procedures cause high radiation exposure levels that exceed the values published thus far. As a consequence, (1) DSAs should be only performed when necessary and with a low image rate, (2) fluoroscopies should be kept as short as possible, and (3) field sizes should be minimized. (orig.)

  18. Long-term recurrence and complication rates after incisional hernia repair with the open onlay technique

    DEFF Research Database (Denmark)

    Andersen, Lars Peter Holst; Klein, Mads; Gögenur, Ismail;

    2009-01-01

    BACKGROUND: Incisional hernia after abdominal surgery is a well-known complication. Controversy still exists with respect to the choice of hernia repair technique. The objective of this study was to evaluate the long-term recurrence rate as well as surgical complications in a consecutive group......% follow-up. The median follow-up was 35 months (range 4-151). Recurrent incisional hernia was found in 8 of 56 patients (15%, 95% CI: 6-24). The overall complication rate was 13% (95% CI, 4-22). All complications were minor and needed no hospital admission. CONCLUSION: This study with a long follow......-up showed low recurrence and complication rates in patients undergoing incisional hernia repair with the open onlay technique....

  19. Single stage repair of a complex pathology: end stage ischaemic cardiomyopathy, ascending aortic aneurysm and thoracic coarctation

    Directory of Open Access Journals (Sweden)

    Parissis Haralabos

    2011-11-01

    Full Text Available Abstract The not uncommon combination of ascending aortic pathology with late presenting coarctation is a difficult surgical challenge. The two stage approach is usually adopted. The necessity for cardiac transplantation adds to the complexity: a trans-sternal approach and single stage repair become mandatory.

  20. A Giant Renal Vein Aneurysm in a Patient with Liver Cirrhosis

    Directory of Open Access Journals (Sweden)

    Konstantinos Filis

    2016-01-01

    Full Text Available We present an unusual case of a 40-year-old female patient with liver cirrhosis and diffuse abdominal pain. The imaging studies revealed a huge renal vein aneurysm. The patient refused any interventional management, despite the risk of possible rupture, and after a week of mild pain therapy, she was discharged. She was followed up closely, and after one year, she remains asymptomatic. Conservative management of such patients has been described before with success. However, open repair or percutaneous thrombosis of the aneurysm remains the indicated therapy, when vein patency is an issue for organ viability.

  1. Repair of inguinal hernia: a comparison between extraperitoneal laparoscopy and Lichtenstein open surgery

    Directory of Open Access Journals (Sweden)

    Tavassoli A

    2010-06-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: The inguinal hernia is a common disorder in general surgery. Different methods have been described for repair of these hernias. In modern methods, synthetic mesh is used to cover the wall defect and the most known method is Lichtenstein surgical repair. The laparoscopic totally extra peritoneal procedure (TEP is a newer technique of repairing hernia. The aim of this study is to compare the outcomes of totally extraperitoneal laparoscopic inguinal hernia repair versus Lichtenstein open repair in patients with inguinal hernia."n"nMethods: Among 50 patients, 25 cases underwent Lichtenstein procedure and 25 patients underwent TEP technique for repairing primary unilateral inguinal hernia. Findings during the operation have been recorded and the 12-months follow-up of patients in different views was performed through a questionnaire and then the results were compared."n"nResults: The operation duration, the rate of complications and frequency of recurrence were similar in two groups; but the hospital stay, postoperative pain, chronic groin pain and the required time to return to normal activity were significantly lower in patients who underwent the TEP method compared to the patients who underwent the

  2. Brain Aneurysm

    Science.gov (United States)

    A brain aneurysm is an abnormal bulge or "ballooning" in the wall of an artery in the brain. They are sometimes called berry aneurysms because they ... often the size of a small berry. Most brain aneurysms produce no symptoms until they become large, ...

  3. Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Pitoulias, Georgios A.; Aslanidou, Eleni A.; Papadimitriou, Dimitrios K. (G Gennimatas Hospital, 2nd Surgical Dept. - Division of Vascular Surgery, Aristotle Univ. of Thessaloniki, Thessaloniki (Greece)), e-mail: pitoulias@yahoo.com; pitoulias@med.auth.gr; Donas, Konstantinos P. (Dept. of Vascular Surgery, St Franziscus Hospital, Muenster (Germany)); Schulte, Stefan (Center for Vascular Medicine and Vascular Surgery, MediaPark Klinik, Cologne (Germany))

    2011-03-15

    Background The morphological analysis prior to endovascular abdominal aneurysm repair (EVAR) plays an important role in long-term outcomes. Post-imaging analysis of computed tomographic angiography (CTA) by three-dimensional reconstruction with central lumen line detection (CLL 3D-CTA) enables measurements to be made in orthogonal slices. This might be more precise than equal post-imaging analysis in axial slices by two-dimensional computed tomographic angiography (2D-CTA). Purpose To evaluate the intra- and interobserver variability of CLL 3D-CTA and 2D-CTA post-imaging analysis methods and the agreement between them in pre-EVAR suitability analysis of patients with abdominal aortic aneurysm (AAA). Material and Methods Anonymized CTA data-sets from 70 patients with AAA were analyzed retrospectively. Length measurements included proximal and distal aortic neck lengths and total distance from the lower renal artery to the higher iliac bifurcation. Width measurements included proximal and distal neck diameters, maximum AAA diameter and common iliac diameters just above the iliac bifurcations. The measurements were performed in random order by two vascular surgeons, twice per method with 1-month interval between readings. In the CLL 3D-CTA method we used semi-automated CLL detection by software and manual measurements on CTA slices perpendicular to CLL. The equal measurements in 2D-CTA were performed manually on axial CTA slices using a DICOM viewer workstation. The intra- and interobserver variability, as well as the agreement between the two methods were assessed by Bland-Altman test and bivariate correlation analysis. Results The intraobserver variability was significantly higher in 2D-CTA measurements for both readers. The interobserver variability was significant in 2D-CTA measurements of proximal neck dimensions while the agreement in CLL 3D-CTA analysis between the two readers was excellent in all studied parameters. The agreement between the two suitability

  4. Clinical and biomechanical outcome of minimal invasive and open repair of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Chan Alexander

    2011-12-01

    Full Text Available Abstract Introduction With evolutions in surgical techniques, minimally invasive surgical (MIS repair with Achillon applicator has been introduced. However, there is still a lack of literature to investigate into the clinical merits of MIS over open surgery. This study aims to investigate the correlation between clinical outcome, gait analysis and biomechanical properties comparing both surgical methods. Materials and methods A single centre retrospective review on all the consecutive operated patients between January 2004 and December 2008 was performed. Twenty-six patients (19 male and 7 female; age 40.4 ± 9.2 years had experienced a complete Achilles tendon rupture with operative repair. Nineteen of the patients, 10 MIS versus 9 open repairs (13 men with a mean age of 40.54 ± 10.43 (range 23-62 yrs and 6 women with a mean age of 45.33 ± 7.71 (range 35-57 yrs were further invited to attend a thorough clinical assessment using Holz's scale and biomechanical evaluation at a mean of 25.3 months after operation. This study utilized the Cybex II isokinetic dynamometer to assess the isokinetic peak force of plantar-flexion and dorsiflexion of both ankles. The patients were also invited to return to our Gait Laboratory for analysis. The eight-infrared camera motion capture system (VICON, UK was utilized for the acquisition of kinematic variables. Their anthropometric data was measured according to the Davis and coworkers' standard. Results The mean operative time and length of hospital stay were shorter in the MIS group. The operative time was 54.55 ± 15.15 minutes versus 68.80 ± 18.23 minutes of the MIS group and Open group respectively (p = 0.045, whereas length of stay was 3.36 ± 1.21 days versus 6.40 ± 3.70 days respectively (p = 0.039. There is statistically significant decrease (p = 0.005 in incision length in MIS group than the open surgery group, 3.23 ± 1.10 cm versus 9.64 ± 2.55 cm respectively. Both groups attained similar Holz

  5. Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Stefanczyk, Ludomir; Elgalal, Marcin, E-mail: telgalal@yahoo.co.uk [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Papiewski, Andrzej [Medical University of Lodz, Department of Gastroenterological Surgery (Poland); Szubert, Wojciech [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Szopinski, Piotr [Institute of Hematology and Transfusion Medicine, Clinic of Vascular Surgery (Poland)

    2013-06-15

    Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

  6. Automatic pose initialization for accurate 2D/3D registration applied to abdominal aortic aneurysm endovascular repair

    Science.gov (United States)

    Miao, Shun; Lucas, Joseph; Liao, Rui

    2012-02-01

    Minimally invasive abdominal aortic aneurysm (AAA) stenting can be greatly facilitated by overlaying the preoperative 3-D model of the abdominal aorta onto the intra-operative 2-D X-ray images. Accurate 2-D/3-D registration in 3-D space makes the 2-D/3-D overlay robust to the change of C-Arm angulations. By far, the 2-D/3-D registration methods based on simulated X-ray projection images using multiple image planes have been shown to be able to provide satisfactory 3-D registration accuracy. However, one drawback of the intensity-based 2-D/3-D registration methods is that the similarity measure is usually highly non-convex and hence the optimizer can easily be trapped into local minima. User interaction therefore is often needed in the initialization of the position of the 3-D model in order to get a successful 2-D/3-D registration. In this paper, a novel 3-D pose initialization technique is proposed, as an extension of our previously proposed bi-plane 2-D/3-D registration method for AAA intervention [4]. The proposed method detects vessel bifurcation points and spine centerline in both 2-D and 3-D images, and utilizes landmark information to bring the 3-D volume into a 15mm capture range. The proposed landmark detection method was validated on real dataset, and is shown to be able to provide a good initialization for 2-D/3-D registration in [4], thus making the workflow fully automatic.

  7. Notch signaling in descending thoracic aortic aneurysm and dissection

    NARCIS (Netherlands)

    Zou, S.; Ren, P.; Nguyen, M.; Coselli, J.S.; Shen, Y.H.; Lemaire, S.A.

    2012-01-01

    BACKGROUND: Descending thoracic aortic aneurysm and dissection (DTAAD) is characterized by progressive medial degeneration, which may result from excessive tissue destruction and insufficient repair. Resistance to tissue destruction and aortic self-repair are critical in preventing medial degenerati

  8. RARE PRESENTATION OF SYMPTOMATIC BILATERAL PROXIMAL POPLITEAL ARTERY ANEURYSM

    Directory of Open Access Journals (Sweden)

    Thulasikumar Ganapathy

    2016-07-01

    Full Text Available True Popliteal artery aneurysm is the most common of all the peripheral artery aneurysms. We present a case of proximal popliteal artery aneurysm involvement both lower limb presented with gangrene in one lower limb and incapacitating claudication pain on the other lower limb. We have successfully repaired both sides aneurysm in the same sitting with Poly Tetra Fluro Ethylene (PTFE graft, as the patient also had multiple venous perforators’ involvement on both sides, which left us only with synthetic graft repair option rather than venous graft repair.

  9. Relationship between acute kidney injury before thoracic endovascular aneurysm repair and in-hospital outcomes in patients with type B acute aortic dissection

    Institute of Scientific and Technical Information of China (English)

    Hong-Mei REN; Xiao WANG; Chun-Yan HU; Bin QUE; Hui AI; Chun-Mei WANG; Li-Zhong SUN; Shao-Ping NIE

    2015-01-01

    Objective Acute kidney injury (AKI) frequently occurs after catheter-based interventional procedures and increases mortality. How-ever, the implications of AKI before thoracic endovascular aneurysm repair (TEVAR) of type B acute aortic dissection (AAD) remain un-clear. This study evaluated the incidence, predictors, and in-hospital outcomes of AKI before TEVAR in patients with type B AAD. Meth-ods Between 2009 and 2013, 76 patients were retrospectively evaluated who received TEVAR for type B AAD within 36 h from symptom onset. The patients were classified into no-AKI vs. AKI groups, and the severity of AKI was further staged according to kidney disease:im-proving global outcomes criteria before TEVAR. Results The incidence of preoperative AKI was 36.8%. In-hospital complications was significantly higher in patients with preoperative AKI compared with no-AKI (50.0%vs. 4.2%, respectively;P<0.001), including acute renal failure (21.4%vs. 0, respectively;P<0.001), and they increased with severity of AKI (P<0.001). The maximum levels of body tem-perature and white blood cell count were significantly related to maximum serum creatinine level before TEVAR. Multivariate analysis showed that systolic blood pressure on admission (OR:1.023;95%CI:1.003–1.044;P=0.0238) and bilateral renal artery involvement (OR:19.076;95%CI:1.914–190.164;P=0.0120) were strong predictors of preoperative AKI. Conclusions Preoperative AKI frequently oc-curred in patients with type B AAD, and correlated with higher in-hospital complications and enhanced inflammatory reaction. Systolic blood pressure on admission and bilateral renal artery involvement were major risk factors for AKI before TEVAR.

  10. Outcome and survival of patients aged 75 years and older compared to younger patients after ruptured abdominal aortic aneurysm repair: do the results justify the effort?

    DEFF Research Database (Denmark)

    Shahidi, S; Schroeder, T Veith; Carstensen, M.

    2009-01-01

    on prospectively registered data. The protocol was an "all-comers" policy. Seventy-two patients, who were operated on for RAAA in our department from January 1, 2005, to December 30, 2005, are included in this study. The follow-up time of survivors was 1 year. We defined 75-year-old patients as elderly because...... the only significant (p believe that treatment for RAAA can be justified in elderly patients. In our experience, surgical open repair has been life-saving in 33% of patients aged 75 years and older, at a relatively low price for each...

  11. Should we abandon regional anesthesia in open inguinal hernia repair in adults?

    Science.gov (United States)

    Bakota, B; Kopljar, M; Baranovic, S; Miletic, M; Marinovic, M; Vidovic, D

    2015-09-17

    Inguinal hernia repair is a common worldwide surgical procedure usually done in the outpatient setting. The purpose of this systematic review is to make an evidence-based meta-analysis to determine the possible benefits of regional (neuraxial block) anesthesia compared to general anesthesia in open inguinal hernia repair in adults. Cochrane Library, Medline, EMBASE, CINAHL, SCI-EXPANDED, SCOPUS as well as trial registries, conference proceedings and reference lists were searched. Only randomized controlled trials (RCT) that compare neuraxial block (spinal or/and epidural) anesthesia (NABA) and general anesthesia (GA) were included. Main outcome measures were postoperative complications, urinary retention and postoperative pain. Seven RCTs were included in this review. A total of 308 patients were analyzed with 154 patients in each group. Overall complications were evenly distributed in NABA and in GA group [OR 1.17, 95 % CI (0.52-2.66)]. Urinary retention was statistically less frequent in GA group compared to NABA group [OR 0.25, 95 % CI (0.08-0.74)]. Movement-associated pain score 24 h after surgery was significantly lower in NABA group [SMD 5.59, 95 % CI (3.69-7.50)]. Time of first analgesia application was shorter in GA group [SMD 8.99, 95 % CI 6.10-11.89]. Compared to GA, NABA appears to be a more adequate technique in terms of postoperative pain control. However, when GA is applied, patients seem to have less voiding problems.

  12. Mycotic aneurysm of the descending thoracic aorta: the role of transesophageal echocardiography.

    Science.gov (United States)

    Joffe, I I; Emmi, R P; Oline, J; Jacobs, L E; Owen, A N; Ioli, A; Najjar, D; Kotler, M N

    1996-01-01

    Mycotic aneurysms of the aorta are prone to rupture. Thus rapid and accurate diagnosis is essential so that surgical repair can be undertaken. We report a case of mycotic aortic aneurysm caused by mitral valve endocarditis. The aneurysm situated at the junction of the thoracoabdominal aorta was readily detected by transesophageal echocardiography. Computed tomography and aortography were complementary to transesophageal echocardiography in establishing the diagnosis. The patient underwent successful repair and acute inflammation of the aneurysm was present at histologic examination.

  13. Ruptured Aortic Aneurysm From Late Type II Endoleak Treated by Transarterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Gunasekaran, Senthil, E-mail: sgunasekaran@lumc.edu [Loyola University Medical Center Chicago (United States); Funaki, Brian, E-mail: bfunaki@radiology.bsd.uchicago.edu; Lorenz, Jonathan, E-mail: jlorenz@radiology.bsd.uchicago.edu [University of Chicago Medical Center (United States)

    2013-02-15

    Endoleak is the most common complication after endovascular aneurysm repair. The most common type of endoleak, a type II endoleak, typically follows a benign course and is only treated when associated with increasing aneurysm size. In this case report, we describe a ruptured abdominal aortic aneurysm due to a late, type II endoleak occurring 10 years after endovascular aneurysm repair that was successfully treated by transarterial embolization.

  14. Comparative study of open tension-free and laparoscopic inguinal hernia repair in hernioplasty and simultaneous laparoscopic cholecystectomy

    Institute of Scientific and Technical Information of China (English)

    JIANG Dao-zhen; QIU Ming; ZHENG Xiang-min; LU Lei; DONG Zhi-tao; HE Yan-fei; JIANG Hang

    2006-01-01

    Objective: To evaluate the clinical value of laparoscopic inguinal hernia repair in hernioplasty and simultaneous cholecystectomy. Methods: Twenty-eight patients with symptomatic chronic calculous cholecystitis and synchronous unilateral primary inguinal hernia were performed combined surgery between October 2001 and March 2005. Of them, 10 cases underwent laparoscopic totally extraperitoneal mesh hernia repair (TEP) and laparoscopic cholecystectomy (LC), 3 cases underwent laparoscopic transabdominal preperitoneal mesh hernia repair (TAPP) and LC, and 15 cases underwent LC and open tension-free hernia repair. Results: All the procedures were performed successfully, 2 patients occurred urinary retention in LC+open group and 1 patient occurred scrotum seroma in LC+TEP procedures. During the 6 to 24 months' follow-up, no hernia recurrences occurred in all patients. There were 6 Patients (40%) in LC +open group had discomfort pain in the inguinal region and lasted 1 to 3 months. The operating time was longer in the totally laparoscopic group (TEP+LC and TAPP+LC) (104±31 min) than in the LC+open group (80±28 min) (P<0.05). The intensity of postoperative pain at rest was greater in the LC+open group at 24 h (P<0.05) and 48 h (P<0.05). No differences between the 2 groups were found in the mean operating costs and oral intake of the postoperative period. But the time resume to walking (2.9 vs 1. 8 d) (P<0.01) and the mean hospital stay (8.2 vs 4.6 d) (P<0. 001) was longer in the LC+open group than in the totally laparoscopic group. Conclusion: In the same operating costs, the totally laparoscopic precedure has more advantages of low postoperative pain, quicker resume to walking and less hospital stay than open tension-free hernia repair in hernioplasty and simultaneous LC. Thus, the totally laparoscopic approach is considered to be advantage of the hernioplasty and simultaneous LC.

  15. Correção endovascular de aneurisma de aorta abdominal em paciente com rim em ferradura: relato de caso Endovascular repair of an abdominal aortic aneurysm in patient with horseshoe kidney: a case report

    Directory of Open Access Journals (Sweden)

    Eduardo Keller Saadi

    2008-09-01

    Full Text Available O rim em ferradura é uma anomalia congênita rara que pode causar várias dificuldades técnicas durante a correção convencional de aneurisma de aorta abdominal. Relatamos o caso de uma paciente de 68 anos com rim em ferradura, aneurisma de aorta abdominal sintomático e disfunção renal leve. A paciente foi submetida a correção endovascular, sendo utilizada uma endoprótese bifurcada. O pós-operatório foi livre de complicações. O diagnóstico e a técnica endovascular são discutidos, assim como a literatura revisada.Horseshoe kidney is a rare congenital anomaly that may cause various technical problems during conventional repairs of abdominal aortic aneurysms. We report the case of a 68-year-old woman with a horseshoe kidney, symptomatic abdominal aortic aneurysm and mild renal failure. The patient underwent endovascular repair using a bifurcated endoprosthesis. The postoperative was uneventful. We describe the diagnosis and the endovascular technique and literature review.

  16. Endovascular treatment of thoracic aortic aneurysms: a review

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, Siegfried A. [Department of Radiology, University Hospital, Wien (Austria); Grabenwoeger, Martin [Department of Cardio-Thoracic Surgery, University of Vienna (Austria)

    2002-06-01

    Open surgical repair is considered the traditional treatment for patients with thoracic aortic aneurysms (TAA). In view of the persistent perioperative mobidity and mortality, endovascular stent-graft placement as a minimally invasive and potentially safer treatment for aneurysm of the descending aorta was introduced in 1992. Since then, progress has been made and several institutions have substantiated the safety and effectiveness of stent grafts in the repair of descending TAAs or type-B aortic dissections. Currently, both custom-designed, home-made, and commercially available stent grafts are used. Prior to placement of the endoprosthesis, three major prerequisites must be considered: the localization and morphology of the aneurysm; the distal vascular access of sufficient size; and a limited tortuosity of the abdominal and thoracic aorta. Although short-term results are encouraging, severe complications, including paraplegia, cerebral strokes, and aortic rupture, have been encountered. The long-term durability of currently available stent-graft systems is nonexistent and material fatigue are of major concern to both surgeons and radiologists. Nevertheless, endovascular stent-graft placement could become the procedure of choice in a substantial number of patients with descending TAA. (orig.)

  17. Optic chiasm compression from mass effect and thrombus formation following unsuccessful treatment of a giant supraclinoid ICA aneurysm with the Pipeline device: open surgical bailout with STA-MCA bypass and parent vessel occlusion.

    Science.gov (United States)

    Abla, Adib A; Zaidi, Hasan A; Crowley, R Webster; Britz, Gavin W; McDougall, Cameron G; Albuquerque, Felipe C; Spetzler, Robert F

    2014-07-01

    Pipeline Embolization Devices (PEDs) have been shown to be effective for intracranial internal carotid artery (ICA) aneurysms, and are now approved by the FDA specifically for this use. Potential pitfalls, however, have not yet been described in the pediatric neurosurgical literature. The authors report on a 10-year-old boy who presented to the Barrow Neurological Institute after progressive visual decline. He had undergone placement of a total of 7 telescoping PEDs at another facility for a large ICA aneurysm. Residual filling of the aneurysm and significant expansion of intraaneurysmal thrombus with chiasmal compression on admission images were causes for concern. The patient underwent a surgical bailout with a superficial temporal artery-middle cerebral artery bypass, with parent artery occlusion. Postoperative vascular imaging was notable for successful occlusion of the parent vessel, with no evidence of filling of the aneurysm. Reports on the pitfalls of PEDs in the neurosurgical literature are scarce. To the authors' knowledge this represents the first paper describing a successful open surgical bailout for residual aneurysmal filling and expansion of thrombus after placement of a PED.

  18. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis ... an abdominal aortic aneurysm treated? What is an abdominal aortic aneurysm? The aorta, the largest artery in the body, ...

  19. Risk assessment and risk scores in the management of aortic aneurysms.

    Science.gov (United States)

    Von Meijenfeldt, Gerdine C I; Van Der Laan, Maarten J; Zeebregts, Clark J; Balm, Ron; Verhagen, Hence J M

    2016-04-01

    The decision whether to operate a patient or not can be challenging for a clinician for both ruptured abdominal aortic aneurysms (AAAs) as well as elective AAAs. Prior to surgical intervention it would be preferable that the clinician exactly knows which clinical variables lower or increase the chances of morbidity and mortality postintervention. To help in the preoperative counselling and shared decision making several clinical variables can be identified as risk factors and with these, risk models can be developed. An ideal risk score for aneurysm repair includes routinely obtained physiological and anatomical variables, has excellent discrimination and calibration, and is validated in different geographical areas. For elective AAA repair, several risk scores are available, for ruptured AAA treatment, these scores are far less well developed. In this manuscript, we describe the designs and results of published risk scores for elective and open repair. Also, suggestions for uniformly reporting of risk factors and their statistical analyses are described. Furthermore, the preliminary results of a new risk model for ruptured aortic aneurysm will be discussed. This score identifies age, hemoglobin, cardiopulmonary resuscitation and preoperative systolic blood pressure as risk factors after multivariate regression analysis. This new risk score can help to identify patients that would not benefit from repair, but it can also potentially identify patients who would benefit and therefore lower turndown rates. The challenge for further research is to expand on validation of already existing promising risk scores in order to come to a risk model with optimal discrimination and calibration.

  20. Reverse Thermal Gel for In Utero Coverage of Spina Bifida Defects: An Innovative Bioengineering Alternative to Open Fetal Repair.

    Science.gov (United States)

    Marwan, Ahmed I; Williams, Sarah M; Bardill, James R; Gralla, Jane; Abdul-Aziz, Noraishah M; Park, Daewon

    2017-01-30

    Current state-of-the-art management of open spina bifida defects entails an open fetal surgery approach associated with significant morbidities. In an attempt to reduce these risks and provide for an earlier minimally invasive repair, it is aimed to develop and characterize an innovative alternative using a unique reverse thermal gel. This study focuses on characterization of the physical and biological properties of the polymer and its in vivo applicability. Based on the knowledge and benchmarking, the "ideal" biomaterial should have the following characteristics: stability in amniotic fluid, limited permeability, biocompatibility, biologically functional, nontoxic, ability to support cellular functions, and in vivo applicability. The results demonstrate that the polymer possesses a unique ultrastructure, is stable in amniotic fluid, possesses limited yet predictable permeability, biocompatible with cells exposed in neural tube defects, is nontoxic, and can support cellular migration. These characteristics make it a potential novel alternative to open fetal repairs.

  1. Preliminary study of the repair process in elastase-induced aneurysms in rabbits%弹力酶诱导兔动脉瘤模型修复过程初步研究

    Institute of Scientific and Technical Information of China (English)

    周加浩; 徐善水; 方兴根; 李真保; 江晓春; 张连富

    2013-01-01

      目的:观察猪胰弹性酶快速诱导建立兔囊状动脉瘤模型的形态学改变和早期病理学变化,探讨动脉瘤的创伤修复机制,为动脉瘤的治疗寻找新的切入点。方法:应用猪胰弹性酶消化兔右侧颈总动脉起始部建立动脉瘤模型,3 d、7 d、21 d灌注取出动脉瘤组织,采用病理学、免疫组织化学、脑血管造影技术研究该模型的影像学和病理学变化。结果:病理学观察发现动脉瘤顶部均有红血栓形成,血管内皮细胞消失,瘤壁完全缺失弹力层,载瘤动脉的弹力层在动脉瘤颈部突然消失,动脉瘤内膜逐渐增生,但仍缺乏弹力层,平滑肌细胞和胶原纤维增生明显。免疫组织化学均显示内膜Von Willebrand因子( vWF )染色阴性。对照组动物均形成动脉残端,动脉残腔内无或少量血栓,血管壁结构完整。造影显示21 d 动脉瘤长径(6.40±1.62) mm,宽径(4.41±1.15)mm,瘤颈宽(5.30±2.51) mm,载瘤动脉直径(3.99±1.59) mm。结论:通过简单外科手术方法结合弹力酶消化局部血管壁,可以建立病理学和形态学上与人颅内动脉瘤相似的动脉瘤模型。动脉瘤模型早期存在一定的自身修复机制,内膜逐渐增生,以平滑肌细胞和胶原纤维增生为主,未见弹力纤维和内皮细胞增生修复。%Objective:To create the elastase-induced saccular aneurysm model in rabbits and observe the morphological and early pathological changes of the tumor for examining the lesion and repair mechanisms of aneurysm to find a breakthrough with tumor treatment .Methods:Experi-mental aneurysm models were developed in rabbits using porcine pancre-atic elastase digestion at the origin of right common carotid artery ( RC-CA).The animals were sacrificed at day 3,7 and 21,respectively,to re-move the aneurysms for examining the in vitro imaging and pathological changes on

  2. Comparative Effectiveness of Two Ultrasound-Guided Regional Block Techniques for Surgical Anesthesia in Open Unilateral Inguinal Hernia Repair.

    Science.gov (United States)

    Steffel, Lauren; Kim, T Edward; Howard, Steven K; Ly, Daphne P; Kou, Alex; King, Robert; Mariano, Edward R

    2016-01-01

    Transversus abdominis plane (TAP) and ilioinguinal/iliohypogastric (II/IH) nerve blocks have been described as analgesic adjuncts for inguinal hernia repair, but the efficacy of these techniques in providing intraoperative anesthesia, either individually or together, is not known. We designed this retrospective cohort study to test the hypothesis that combining TAP and II/IH nerve blocks ("double TAP" technique) results in greater accordance between the preoperative anesthetic plan and actual anesthetic technique provided when compared to TAP alone. Based on this study, double TAP may be preferred for patients undergoing open inguinal hernia repair who wish to avoid general anesthesia.

  3. Delayed diagnosis of hemoptysis in the case of prior aortic coarctation repair: A case report of aortobronchial fistula

    Directory of Open Access Journals (Sweden)

    Vinay Kansal

    2015-01-01

    Full Text Available We report a case of a 46-year old man who presented with spontaneous bright red blood per mouth for several months. The patient had history of aortic coarctation repair at age 17. Endoscopy and nasopharyngeoscopy revealed no source of bleeding. Computed tomography scan revealed the presence of thoracic aortic pseudoaneurysm with the formation of an aortobronchial fistula (ABF. This case illustrates the high index of suspicion for ABF in the case of hemoptysis or hematemesis with prior history of coarctation repair. Furthermore, we discuss the role of thoracic endovascular aneurysm repair (TEVAR as the standard of repair over open surgery.

  4. Endovascular Treatment of Isolated Bilateral Internal Ili- ac Artery Aneurysms with a Branched Endograft: A Case Report

    Directory of Open Access Journals (Sweden)

    SeyedEbrahim Kassaian

    2015-10-01

    Full Text Available Isolated bilateral internal iliac artery (IIA aneurysm is a rare and potentially lethal disease. Endovascular repair of this disorder is a matter of debate. A symptomatic 68-year-old male presented with severe pelvic pains. Computed tomography revealed a leaking 46-mm aneurysm in the right IIA, a 27-mm aneurysm in the left IIA, and ectatic changes at a diameter of 31 mm in the right common iliac artery (CIA. Due to lower rates of morbidity and mortality, an endovascular approach was chosen instead of open surgical repair. However, due to anatomical constraints, an endograft had to be implanted in a healthy aorta in order to support an iliac branch endograft in the left CIA. Subsequently, following coil embolization of the left IIA, an iliac stent graft was extended to the right external iliac artery (EIA. Two-year follow-up CT imaging showed complete exclusion of all the aneurysms and patency of the pelvic visceral arteries. The patient is currently asymptomatic.Endovascular repair of bilateral isolated IIAs can be a feasible treatment option. However, due to limited availability of sizes in iliac branch devices currently on the market, a main body device is sometimes required to be deployed in a healthy aorta for additional endograft support.

  5. Minimal Incision Scar-Less Open Umbilical Hernia Repair in Adults - Technical Aspects and Short Term Results

    Directory of Open Access Journals (Sweden)

    Sanoop Koshy Zachariah

    2014-09-01

    Full Text Available Background: There is no gold standard technique for umbilical hernia repair .Conventional open umbilical hernia repair often produces an undesirable scar. Laparoscopic umbilical hernia repair requires multiple incisions beyond the umbilicus, specialized equipments, and expensive tissue separating mesh. We describe our technique of open umbilical hernia repair utilizing a small incision. The technique was derived from our experience with single incision laparoscopy. We report the technical details and short term results. Methods: This is a retrospective analysis of the first 20 patients who underwent minimal incision scar-less open umbilical hernia repair, from June 2011 to February 2014. A single intra-umbilical curved incision was used to gain access to the hernia sac. Primary suture repair was performed for defects upto 2cm.Larger defects were repaired using an onlay mesh. In patients with a BMI of 30 kg/m2 or greater, onlay mesh hernioplasty was performed irrespective of the defect size.Results: A total of 20 patients, 12 males and 8 females underwent the procedure. Mean age was 50 (range 29 - 82 years. Mean BMI was 26.27 (range 20. -33.1 kg/m2. Average size of the incision was 1.96 range (1.5 to 2.5 cm. Mesh hernioplasty was done in 9 patients. 11 patients underwent primary suture repair alone. There were no postoperative complications associated with his technique. Average post operative length of hospital stay was 3.9 (range 2-10 days. Mean follow-up was 29.94 months, (2 weeks to 2.78 years. On follow up there was no externally visible scar in any of the patients. There were no recurrences on final follow up. Conclusion: This technique provides a similar cosmetic effect as obtained from single port laparoscopy. It is easy to perform safe, offers good cosmesis, does not require incisions beyond the umbilicus and cost effective, with encouraging results on short term follow up. Further research is needed to assess the true potential of the

  6. Aortic aneurysm repair - endovascular - discharge

    Science.gov (United States)

    ... eds. Current Surgical Therapy . 11th ed. Philadelphia, PA: Elsevier Saunders; 2014:783-787. Hammond CJ, Nicholson AA. ... of Medical Imaging . 6th ed. New York, NY: Elsevier Churchill Livingstone; 2015:chap 85. Sternbergh WC. Technique: ...

  7. Infection of endovascular abdominal aortic aneurysm stent graft after urosepsis: case report and review of the literature.

    Science.gov (United States)

    Veger, H T C; Hedeman Joosten, P Ph; Thoma, S R; Visser, M J T

    2013-02-01

    Infection of endovascular abdominal aneurysm stent grafts is an uncommon but known complication. Inoculation with bacteria of the endovascular abdominal aneurysm stent graft during the actual implantation, in the periprocedural hospitalization or later due to an aortoenteric fistula, has been described in the literature. We report a case of endovascular abdominal aortic aneurysm stent graft infection occurring 40 months after implantation in a patient doing well up to an episode of urosepsis. In conclusion, we postulate that poor intraluminal healing of stent grafts, as observed in several explant studies, may result in a higher susceptibility to episodes of bacteremia than prosthetic vascular grafts inserted during open repair. We therefore consider the administration of prophylactic antibiotics in patients with endovascular stent grafts during periods with a likelihood of bacteremia.

  8. Preservação das artérias hipogástricas com endoprótese ramificada no tratamento endovascular de aneurismas aorto-ilíacos The Zenith iliac bifurcation Device (IBD for preservation of the internal iliac arteries during endovascular repair of aortic-iliac aneurysms

    Directory of Open Access Journals (Sweden)

    Emanuel Dias

    2010-12-01

    gluteal claudication, intestinal ischemia, vesical and intestinal disfunction, neurologic deficits and impotence. The use of branched endoprothesis with preservation of the hypgastric artery is a recente innovation to reduce such complications. Clinical case: A 63 year-old male, previously submitted to an open repair of an abdominal aortic aneurysm with an aorto-aortic prothesis, was admitted for endovascular treatment of an aneurysm of the right common and internal iliac arteries with 3,3cm. A Zenith® branched endoprothesis with a branch to the iliac bifurcation was deployed via right femoral access, thus assuring preservation of the hypogastric artery. Conclusion: Hypogastric preservation necessity during EVAR in aorto-iliac aneurysms may be achieved in a secure and simple way through the placement of endoprothesis to the iliac bifurcation.

  9. Endovascular Treatment of Infrarenal Abdominal Aortic Aneurysm with Short and Angulated Neck in High-Risk Patient

    Directory of Open Access Journals (Sweden)

    Stylianos Koutsias

    2013-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA is an established alternative to open repair. However lifelong surveillance is still required to monitor endograft function and signal the need for secondary interventions (Hobo and Buth 2006. Aortic morphology, especially related to the proximal neck, often complicates the procedure or increases the risk for late device-related complications (Hobo et al. 2007 and Chisci et al. 2009. The definition of a short and angulated neck is based on length (60° (Hobo et al. 2007 and Chisci et al. 2009. A challenging neck also offers difficulties during open repairs (OR, necessitating extensive dissection with juxta- or suprarenal aortic cross-clamping. Patients with extensive aneurysmal disease typically have more comorbidities and may not tolerate extensive surgical trauma (Sarac et al. 2002. It is, therefore, unclear whether aneurysms with a challenging proximal neck should be offered EVAR or OR (Cox et al. 2006, Choke et al. 2006, Robbins et al. 2005, Sternbergh III et al. 2002, Dillavou et al. 2003, and Greenberg et al. 2003. In our case the insertion of a thoracic endograft followed by the placement of a bifurcated aortic endograft for the treatment of a very short and severely angulated neck proved to be feasible offering acceptable duration of aneurysm exclusion. This adds up to our armamentarium in the treatment of high-risk patients, and it should be considered in emergency cases when the fenestrated and branched endografts are not available.

  10. The effect of endovascular treatment on isolated iliac artery aneurysm treatment and mortality

    NARCIS (Netherlands)

    Buck, Dominique B.; Bensley, Rodney P.; Darling, Jeremy; Curran, Thomas; McCallum, John C.; Moll, Frans L.; Van Herwaarden, Joost A.; Schermerhorn, Marc L.

    2015-01-01

    Objective Isolated iliac artery aneurysms are rare, but potentially fatal. The effect of recent trends in the use of endovascular iliac aneurysm repair (EVIR) on isolated iliac artery aneurysm-associated mortality is unknown. Methods We identified all patients with a primary diagnosis of iliac arter

  11. Percutaneous Zenith endografting for abdominal aortic aneurysms.

    Science.gov (United States)

    Heyer, Kamaldeep S; Resnick, Scott A; Matsumura, Jon S; Amaranto, Daniel; Eskandari, Mark K

    2009-03-01

    A completely percutaneous approach to infrarenal abdominal aortic aneurysm (AAA) endografting has the theoretic benefits of being minimally invasive and more expedient. Our goal was to demonstrate the utility of this approach using a suprarenal fixation device and a suture-mediated closure system. We conducted a single-institution, retrospective review of 14 patients who underwent percutaneous AAA repair with the Zenith device between August 2003 and March 2007. Immediate and delayed access-related outcomes were examined over a mean follow-up of 12.1+/-2.0 months. Mean AAA size was 5.6 cm. Immediate arterial closure and technical success rate was 96% (27/28 vessels). One immediate hemostatic failure required open surgical repair. Over follow-up, one vessel required operative repair for new-onset claudication. No other immediate or delayed complications (thrombosis, pseudoaneurysm, infection, or deep venous thrombosis) were detected. A percutaneous approach for the treatment of AAA has several advantages over femoral artery cutdown but also has its own unique set of risks in the immediate and late postoperative period. Ultimately, the "preclose technique" can be safely applied for the Zenith device despite its large-bore delivery system.

  12. Mesh Location in Open Ventral Hernia Repair: A Systematic Review and Network Meta-analysis.

    Science.gov (United States)

    Holihan, Julie L; Nguyen, Duyen H; Nguyen, Mylan T; Mo, Jiandi; Kao, Lillian S; Liang, Mike K

    2016-01-01

    There is no consensus on the ideal location for mesh placement in open ventral hernia repair (OVHR). We aim to identify the mesh location associated with the lowest rate of recurrence following OVHR using a systematic review and meta-analysis. A search was performed for studies comparing at least two of four locations for mesh placement during OVHR (onlay, inlay, sublay, and underlay). Outcomes assessed were hernia recurrence and surgical site infection (SSI). Pairwise meta-analysis was performed to compare all direct treatment of mesh locations. A multiple treatment meta-analysis was performed to compare all mesh locations in the Bayesian framework. Sensitivity analyses were planned for the following: studies with a low risk of bias, incisional hernias, by hernia size, and by mesh type (synthetic or biologic). Twenty-one studies were identified (n = 5,891). Sublay placement of mesh was associated with the lowest risk for recurrence [OR 0.218 (95% CI 0.06-0.47)] and was the best of the four treatment modalities assessed [Prob (best) = 94.2%]. Sublay was also associated with the lowest risk for SSI [OR 0.449 (95% CI 0.12-1.16)] and was the best of the 4 treatment modalities assessed [Prob (best) = 77.3%]. When only assessing studies at low risk of bias, of incisional hernias, and using synthetic mesh, the probability that sublay had the lowest rate of recurrence and SSI was high. Sublay mesh location has lower complication rates than other mesh locations. While additional randomized controlled trials are needed to validate these findings, this network meta-analysis suggests the probability of sublay being the best location for mesh placement is high.

  13. [An inflammatory aortic aneurysm ruptured into the retroperitoneum and an extensive communication of the aneurysm with the vena cava inferior].

    Science.gov (United States)

    Tovar Martín, E; Acea Nebril, B; Díaz Pardeiro, P

    1993-01-01

    Aortocaval fistula is a rare complication of abdominal aortic aneurysms that occurs with a frequency of 1% of operative cases or less. In this report we present a case of aortocaval fistula associated with ruptured and inflammatory aortic aneurysm that became apparent after evacuation of the thrombus. The inferior cava was ligated. We discuss the clinical syndrome and the management of patients with aortocaval fistula secondary to an abdominal aortic aneurysm and the results of surgical repair.

  14. The use of a new hybrid stentgraft for the repair of extensive thoracic aortic aneurysms with the frozen elephant trunk method - first Polish experiences.

    Science.gov (United States)

    Zembala, Michał; Krasoń, Marcin; Hrapkowicz, Tomasz; Przybylski, Roman; Filipiak, Krzysztof; Borowicz, Marcin; Niklewski, Tomasz; Głowacki, Jan; Wolny, Tomasz; Nadziakiewicz, Paweł; Walas, Ryszard; Zembala, Marian

    2014-09-01

    The frozen elephant trunk (FET) technique is a modification of the traditional elephant trunk method, which was introduced by Borst in 1983 in order to treat extensive thoracic aortic aneurysms. The crux of the new method is the different type of aortic prosthesis, consisting of a Dacron part (with or without branches leading to the arterial vessels which exit the aortic arch) and a port for extracorporeal circulation with a self-expanding nitinol stentgraft. This combination enables a complete one-stage treatment of the pathologies within the arch and the proximal segment of the descending aorta; moreover, it facilitates the performance of a two-stage hybrid treatment of extensive thoracic aortic aneurysms involving a significant part of the descending aorta. This article presents the cases of four patients with extensive aortic disease, who were implanted with Thoraflex prostheses (Vascutek, Scotland).

  15. The use of a new hybrid stentgraft for the repair of extensive thoracic aortic aneurysms with the frozen elephant trunk method – first Polish experiences

    Science.gov (United States)

    Krasoń, Marcin; Hrapkowicz, Tomasz; Przybylski, Roman; Filipiak, Krzysztof; Borowicz, Marcin; Niklewski, Tomasz; Głowacki, Jan; Wolny, Tomasz; Nadziakiewicz, Paweł; Walas, Ryszard; Zembala, Marian

    2014-01-01

    The frozen elephant trunk (FET) technique is a modification of the traditional elephant trunk method, which was introduced by Borst in 1983 in order to treat extensive thoracic aortic aneurysms. The crux of the new method is the different type of aortic prosthesis, consisting of a Dacron part (with or without branches leading to the arterial vessels which exit the aortic arch) and a port for extracorporeal circulation with a self-expanding nitinol stentgraft. This combination enables a complete one-stage treatment of the pathologies within the arch and the proximal segment of the descending aorta; moreover, it facilitates the performance of a two-stage hybrid treatment of extensive thoracic aortic aneurysms involving a significant part of the descending aorta. This article presents the cases of four patients with extensive aortic disease, who were implanted with Thoraflex prostheses (Vascutek, Scotland). PMID:26335241

  16. Streptococcus pyogenes aortic aneurysm infection: forgotten but not gone

    Directory of Open Access Journals (Sweden)

    Bradley J. Gardiner

    2013-11-01

    Full Text Available Historically, Streptococcus pyogenes was a common cause of endocarditis and infected aortic aneurysm. Today, endovascular infections due to this organism have become exceedingly rare. We report the first case of aortic aneurysm infection due to S. pyogenes treated with initial endoluminal repair, review previous reports and discuss current treatment options.

  17. 炎性腹主动脉瘤诊断及治疗%Diagnosis and treatment progression of inflammatory abdominal aortic aneurysms

    Institute of Scientific and Technical Information of China (English)

    黄新天

    2012-01-01

    Inflammatory abdominal aortic aneurysms (iAAA)are a variant of aortic aneurysm characterized by extensive peri-aneurysmal fibrosis, thickened walls and dense adhesions and represent between 2% and 10% of all abdominal aortic aneurysms (AAA). The etiology of iAAA is understood poorly. Aneurysm development is multifactorial with important genetic and environmental factors. Computed tomography (CT) has become the mainstay of assessing iAAA. The perioperative mortality associated with open iAAA repair is increased compared with normal AAAs, largely due to intraoperative technical difficulties related to inflammation. Endovascular repair (EVAR) for iAAA results in successful management with improvement of periaortic inflammation. It is particularly useful when open repair has failed. EVAR should be considered as first-line therapy in which anatomic parameters are favorable.%炎性腹主动脉瘤(inflammatory abdominal aortic aneurysms,iAAA)是腹主动脉瘤的一种特殊类型,占腹主动脉瘤的2%~10%,其病因、发病机制仍然不清,病理特征为瘤壁增厚、瘤周广泛纤维化、腹腔内粘连.CT能可靠显示主动脉周围环状炎性物质,已逐渐变成诊断iAAA的主流方法.腹腔广泛的炎性纤维化使外科手术治疗iAAA存在较大风险,但血管腔内治疗使动脉瘤周围炎症改善,特别适合外科手术失败者.目前,血管腔内修复已被推荐为iAAA一线治疗方法.

  18. The use of a new hybrid stentgraft for the repair of extensive thoracic aortic aneurysms with the frozen elephant trunk method – first Polish experiences

    OpenAIRE

    Zembala, Michał; Krasoń, Marcin; Hrapkowicz, Tomasz; Przybylski, Roman; Filipiak, Krzysztof; Borowicz, Marcin; Niklewski, Tomasz; Głowacki, Jan; Wolny, Tomasz; Nadziakiewicz, Paweł; Walas, Ryszard; Zembala, Marian

    2014-01-01

    The frozen elephant trunk (FET) technique is a modification of the traditional elephant trunk method, which was introduced by Borst in 1983 in order to treat extensive thoracic aortic aneurysms. The crux of the new method is the different type of aortic prosthesis, consisting of a Dacron part (with or without branches leading to the arterial vessels which exit the aortic arch) and a port for extracorporeal circulation with a self-expanding nitinol stentgraft. This combination enables a comple...

  19. Vertebral Artery Aneurysm Mimicking as Left Subclavian Artery Aneurysm in a Patient with Transforming Growth Factor Beta Receptor II Mutation.

    Science.gov (United States)

    Afifi, Rana O; Dhillon, Baltej Singh; Sandhu, Harleen K; Charlton-Ouw, Kristofer M; Estrera, Anthony L; Azizzadeh, Ali

    2015-10-01

    We report successful endovascular repair of a left vertebral artery aneurysm in a patient with transforming growth factor beta receptor II mutation. The patient was initially diagnosed with a left subclavian artery aneurysm on computed tomography angiography. The patient consented to publication of this report.

  20. Modification of an endovascular stent graft for abdominal aortic aneurysm

    Science.gov (United States)

    Moloye, Olajompo Busola

    Endovascular surgery is currently used to treat abdominal aortic aneurysms (AAA). A stent graft is deployed to exclude blood flow from the aneurysm sac. It is an effective procedure used in preventing aneurysm rupture, with reduced patient morbidity and mortality compared to open surgical repair. Migration and leakage around the device ("endoleak") due to poor sealing of the stent graft to the aorta have raised concerns about the long-term durability of endovascular repair. A preliminary study of cell migration and proliferation is presented as a prelude to a more extensive in vivo testing. A method to enhance the biological seal between the stent graft and the aorta is proposed to eliminate this problem. This can be achieved by impregnating the stent graft with 50/50 poly (DL-lactide co glycolic acid) (PLGA) and growth factors such as basic fibroblast growth factor (bFGF) or connective tissue growth factor (CTGF), at the proximal and distal ends. It is hypothesized that as PLGA degrades it will release the growth factors that will promote proliferation and migration of aortic smooth muscle cells to the coated site, leading to a natural seal between the aorta and the stent graft. In addition, growth factor release should promote smooth muscle cell (SMC) contraction that will help keep the stent graft in place at the proximal and distal ends. It is shown that a statistically significant effect of increased cell proliferation and migration is observed for CTGF release. Less of an effect is noted for bFGF or just the PLGA. The effect is estimated to be large enough to be clinically significant in a future animal study. The long term goal of this study is to reduce migration encounter after graft deployment and to reduce secondary interventions of EVAR especially for older patients who are unfit for open surgical treatment.

  1. Laparoscopic versus Open Omental Patch Repair for Early Presentation of Perforated Peptic Ulcer: Matched Retrospective Cohort Study

    Directory of Open Access Journals (Sweden)

    Daniel Jin Keat Lee

    2016-01-01

    Full Text Available Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR in patients with similar presentation of perforated peptic ulcer (PPU. The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation 21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p<0.01. Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases.

  2. Salvage of a failed open gastrocutaneous fistula repair with an endoscopic over-the-scope clip

    Directory of Open Access Journals (Sweden)

    Joshua Jaramillo

    2016-05-01

    Full Text Available Once enteral access via gastrostomy tube (G-tube is no longer indicated, the tube is typically removed in clinic with a high probability of spontaneous closure. When spontaneous closure is not achieved, the formation of a gastrocutaneous fistula (GCF is possible. The incidence of GCF is directly related with the length of time the tube has been placed. When conservative management fails, surgical intervention is the standard treatment. Endoscopic techniques have been described for primary closure of GCF in adults including banding and cauterizing of the fistula tract with placement of a standard endoscopic clip. Over-the-scope clips (OTSC have recently been reported in primary GCF closure in children (Wright et al., 2015. In patients with skin irritation surrounding a GCF making surgical repair difficult, endoscopic OTSC closure provides particular benefit. It is our belief that this is the first case report of endoscopically salvaging a leak from a failed open GCF repair.

  3. [Pediatric case of congenital coronary artery fistula; surgical result and late changes in coronary artery aneurysm].

    Science.gov (United States)

    Sugawara, Masaaki; Oguma, Fumiaki; Hirahara, Hiroyuki

    2014-07-01

    Congenital coronary artery fistula is an uncommon heart anomaly involving the coronary arteries. We report here a case of a 4-year-old boy who had a coronary fistula from the right coronary artery to the right ventricle, with a coronary aneurysm. He was asymptomatic, but the calculated ratio of pulmonary blood flow to systemic blood flow was shown to be high [pulmonary flow (Qp)/systemic flow(Qs)=1.78]. The coronary angiography showed that the right coronary artery was dilated beginning at the ostium and had an aneurysm at the acute marginal portion. A large spherical aneurysm approximately 20 mm in diameter was found to have been connected with coronary fistula opening into the right ventricle. Surgical repair by closure of the fistula under direct vision, partial resection and suture closure of the aneurysm was performed. Plication of the proximal portion of the right coronary artery was not performed, and the diffusely dilated artery was left untouched. After this operation, he recovered well under anticoagulant treatment with warfarin and aspirin. Postoperative angiography was performed 17 months after the surgery to evaluate morphological changes in the coronary artery. The angiography confirmed the closure of the fistula and the regression of coronary artery dilatation.

  4. Mycotic Saccular Abdominal Aortic Aneurysm in an Infant after Cardiac Catheterization: A Case Report.

    Science.gov (United States)

    Benrashid, Ehsan; McCoy, Christopher C; Rice, Henry E; Shortell, Cynthia K; Cox, Mitchell W

    2015-10-01

    Abdominal aortic aneurysms (AAAs) are a rare entity in the pediatric population. Children with mycotic (infectious) AAA in particular are at risk of life-threatening rupture due to their rapid expansion coupled with aortic wall thinning and deterioration. Here, we present the case of a 10-month-old infant with prior 2-staged repair for hypoplastic left heart syndrome that was incidentally discovered to have a mycotic AAA on abdominal ultrasound (US) for evaluation of renovascular hypertension. Before the time of evaluation with US, the infant had developed methicillin-resistant Staphylococcus aureus bacteremia 3 days after cardiac catheterization with percutaneous thoracic aortic balloon angioplasty. She had normal aortic contours on contrasted computed tomography scan of the abdomen approximately 2 weeks before the aforementioned US evaluation. This infant subsequently underwent open aneurysmorrhaphy with cryopreserved vein patch angioplasty with resolution of her aneurysmal segment.

  5. OUTCOME OF ELECTIVE PROPHYLACTIC ILIOINGUINAL NEURECTOMY IN PREVENTION OF CHRONIC GROIN PAIN AFTER OPEN INGUINAL HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Suneel

    2016-04-01

    Full Text Available BACKGROUND Chronic groin pain is one of the most important complications of the repair of inguinal hernia. Randomized trials have identified that chronic groin pain (>10% surpasses recurrence (<2%. Factors proposed as predictors of post-operative pain are damage to inguinal nerves, nerve entrapment during suturing, fibrosis of the placed material as well as that of surrounding area, mesh implantation, partial division and neuroma formation. Routine ilioinguinal division or excision has been associated with a lower incidence of post-operative neuralgia compared to nerve preservation with reduced morbidity and no detrimental effect on quality of life. OBJECTIVE The purpose of our study was to assess the effects of prophylactic ilioinguinal neurectomy on the incidence and intensity of groin pain after open inguinal hernia repair. PATIENTS AND METHODS A total of 50 patients with uncomplicated inguinal hernias were subjected to Lichtenstein mesh hernioplasty with prophylactic ilioinguinal neurectomy over a period of one year (November 2014 - October 2015. Relation of pain to Rest (R, Activities (A and Exercise (E preoperatively and at 1, 3 and 6 months after surgery was noted. McGill Pain Questionnaire was used to assess pain 1 week after surgery, 4 weeks after surgery and after 3 and 6 months of surgery. RESULTS Routine ilioinguinal neurectomy during open groin hernia repair was associated with mean McGill pain score of 1.76 and 1.48 at follow-up period of 3 and 6 months, respectively. Numbness was present in 12% patients at follow-up period of 3 and 6 months. At 3 and 6 months follow-up, pain at rest was present in 2% and 0% patients; pain only during daily activities was present in 4% and 2% patients; and pain only during exercise was present in 6% and 4% patients, respectively. Only 2% patients required analgesics to control pain at 3 months and no patient required analgesics to control pain at 6 months. CONCLUSIONS Ilioinguinal neurectomy during

  6. Case report: rupture of popliteal artery aneurysm

    Directory of Open Access Journals (Sweden)

    Altino Ono Moraes

    2015-06-01

    Full Text Available An 83-year-old female patient with a history of prior endovascular treatment to repair an abdominal aortic aneurysm presented with intense pain and edema in the left leg, with hyperemia and localized temperature increase. Doppler ultrasonography revealed a voluminous aneurysm of the popliteal artery with a contained rupture, and hematoma involving the popliteal fossa and the medial and anterior surfaces of the knee causing compression of the popliteal vein. Endovascular repair was accomplished with covered stents and the rupture was confirmed. during the procedure The aneurysm was excluded and the signs and symptoms it had caused resolved completely, but during the postoperative period the patient developed sepsis of pulmonary origin and died.

  7. Comparison of Porcine Small Intestinal Submucosa versus Polypropylene in Open Inguinal Hernia Repair: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Xin Nie

    Full Text Available A systematic review and meta-analysis was performed in randomized controlled trials (RCTs to compare porcine small intestinal submucosa (SIS with polypropylene in open inguinal hernia repair.Electronic databases MEDLINE, Embase, and the Cochrane Library were used to compare patient outcomes for the two groups via meta-analysis.A total of 3 randomized controlled trials encompassing 200 patients were included in the meta-analysis. There was no significant difference in recurrence (P = 0.16, hematomas (P = 0.06, postoperative pain within 30 days (P = 0.45, or postoperative pain after 1 year (P = 0.12 between the 2 groups. The incidence of discomfort was significantly lower (P = 0.0006 in the SIS group. However, the SIS group experienced a significantly higher incidence of seroma (P = 0.03.Compared to polypropylene, using SIS in open inguinal hernia repair is associated with a lower incidence of discomfort and a higher incidence of seroma. However, well-designed larger RCT studies with a longer follow-up period are needed to confirm these findings.

  8. Coexistence of intracranial epidermoid tumor and multiple cerebral aneurysms

    Science.gov (United States)

    Yao, Pei-Sen; Lin, Zhang-Ya; Zheng, Shu-Fa; Lin, Yuan-Xiang; Yu, Liang-Hong; Jiang, Chang-Zhen; Kang, De-Zhi

    2017-01-01

    Abstract Rationale: There were a few case reports concerning epidermoid tumor coexisted with multiple cerebral aneurysms. Here, we present one case of coexistence of intracranial epidermoid tumor and multiple cerebral aneurysms and performed a literature review. Patient concerns: A 42 years old male patient was admitted to our institution with complaints of headache and dizziness. Interventions: The radiological examinations showed a hypointense lesion in the right parasellar and petrous apex region and an ipsilateral saccular aneurysm originated from the M2–M3 junction of the right middle cerebral artery (MCA) and a saccular aneurysm of the clinoid segment of right internal carotid artery (ICA). Interventions: The patients underwent a right frontotemporal approach for removal of the epidermoid tumor and clipping of the MCA aneurysm in one stage. The aneurysm located at the clinoid segment of ICA was invisible and untreated during operation. Outcomes: No postoperative complications were found in the patient. The patient's follow up after 5 years of surgical treatment was uneventful, and the untreated aneurysm remains stable. Lessons: The coexistence of intracranial epidermoid tumor and cerebral aneurysm is a rare event. The secondly inflammation in cerebral arterial wall may be responsible for the aneurysm formation. Surgical treatment of the intracranial epidermoid tumor and cerebral aneurysm repair may be an optimal scheme in one stage. PMID:28151901

  9. Molecular basis and genetic predisposition to intracranial aneurysm.

    Science.gov (United States)

    Tromp, Gerard; Weinsheimer, Shantel; Ronkainen, Antti; Kuivaniemi, Helena

    2014-12-01

    Intracranial aneurysms, also called cerebral aneurysms, are dilatations in the arteries that supply blood to the brain. Rupture of an intracranial aneurysm leads to a subarachnoid hemorrhage, which is fatal in about 50% of the cases. Intracranial aneurysms can be repaired surgically or endovascularly, or by combining these two treatment modalities. They are relatively common with an estimated prevalence of unruptured aneurysms of 2%-6% in the adult population, and are considered a complex disease with both genetic and environmental risk factors. Known risk factors include smoking, hypertension, increasing age, and positive family history for intracranial aneurysms. Identifying the molecular mechanisms underlying the pathogenesis of intracranial aneurysms is complex. Genome-wide approaches such as DNA linkage and genetic association studies, as well as microarray-based mRNA expression studies, provide unbiased approaches to identify genetic risk factors and dissecting the molecular pathobiology of intracranial aneurysms. The ultimate goal of these studies is to use the information in clinical practice to predict an individual's risk for developing an aneurysm or monitor its growth or rupture risk. Another important goal is to design new therapies based on the information on mechanisms of disease processes to prevent the development or halt the progression of intracranial aneurysms.

  10. Hybrid treatment of recurring thoracoabdominal aortic aneurysm concomitant with retrograde type A aortic dissection

    Institute of Scientific and Technical Information of China (English)

    ZHANG Min-hong; GUO Wei; DU Xin; XIONG Jiang

    2010-01-01

    So far, standard therapy of complex thoracoabdominal aortic disease is open surgical repair requiring aortic clamping and replacement of the involved segment.Despite significant improvements, morbidity and mortality of open surgery remain high.I As a result, open surgery is often withheld owing to severe comorbidities of the patients. Endovascular technique has emerged as an alternative for treatment of these diseases in high risk patients,2 and has enlarged the options of treatment of complex aortic diseases. However, an endovascular approach alone is often deemed unsuitable for some complex aortic disorders because of the close proximity of the supraaortic or visceral branches. A hybrid open-endovascular approach has therefore been proposed as a viable alternative. We present here a unique patient with recurring thoracoabdominal aortic aneurysm (TAAA) concomitant with an aortic dissection (AD) treated by a hybrid open-endovascular approach.

  11. Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Goltz, Jan Peter, E-mail: janpeter.goltz@uksh.de; Loesaus, Julia; Frydrychowicz, Alex; Barkhausen, Jörg [University Hospital of Schleswig-Holstein, Department for Radiology and Nuclear Medicine (Germany); Wiedner, Marcus [University Hospital of Schleswig-Holstein, Clinic for Surgery (Germany)

    2016-02-15

    We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

  12. 如何做好腹主动脉瘤腔内修复术%How to do well at endovascular repairing of abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    符伟国; 施德兵

    2007-01-01

    腹主动脉瘤(abdominal aortic aneurysm,AAA)为血管外科临床重要疾病之一,随瘤体增大,其增长速度加快,破裂风险增加,破裂AAA的病死率高。多数AAA患者因高龄或伴有其他严重内科疾病而不适于行开放手术。1991年,阿根廷Parodi等首次报道用支架型人工血管(后简称“支架”)成功治愈AAA,开创了AAA腔内修复治疗(endovascular aneurysm repair,EVAR)的新时代。以下将就如何做好AAA的EVAR的相关问题作一探讨。

  13. Micromanaging Abdominal Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Lars Maegdefessel

    2013-07-01

    Full Text Available The contribution of abdominal aortic aneurysm (AAA disease to human morbidity and mortality has increased in the aging, industrialized world. In response, extraordinary efforts have been launched to determine the molecular and pathophysiological characteristics of the diseased aorta. This work aims to develop novel diagnostic and therapeutic strategies to limit AAA expansion and, ultimately, rupture. Contributions from multiple research groups have uncovered a complex transcriptional and post-transcriptional regulatory milieu, which is believed to be essential for maintaining aortic vascular homeostasis. Recently, novel small noncoding RNAs, called microRNAs, have been identified as important transcriptional and post-transcriptional inhibitors of gene expression. MicroRNAs are thought to “fine tune” the translational output of their target messenger RNAs (mRNAs by promoting mRNA degradation or inhibiting translation. With the discovery that microRNAs act as powerful regulators in the context of a wide variety of diseases, it is only logical that microRNAs be thoroughly explored as potential therapeutic entities. This current review summarizes interesting findings regarding the intriguing roles and benefits of microRNA expression modulation during AAA initiation and propagation. These studies utilize disease-relevant murine models, as well as human tissue from patients undergoing surgical aortic aneurysm repair. Furthermore, we critically examine future therapeutic strategies with regard to their clinical and translational feasibility.

  14. Repair of a bowel-containing, scrotal hernia with incarceration contributed by femorofemoral bypass graft

    Science.gov (United States)

    Sharma, Gaurav; Schouten, Jonathan A.; Itani, Kamal M. F.

    2017-01-01

    The rising use of endovascular techniques utilizing femoral artery access may increase the frequency with which surgeons face the challenge of hernia repair in reoperative groins—which may or may not include a vascular graft. We present a case where a vascular graft contributed to an acute presentation and complicated dissection, and review the literature. A 67-year-old man who had undergone prior endovascular aneurysm repair via open bilateral femoral artery access and concomitant prosthetic femorofemoral bypass, presented with an incarcerated, scrotal inguinal hernia. The graft with its associated fibrosis contributed to the incarceration by compressing the inguinal ring. Repair was undertaken via an open, anterior approach with tension-free, Lichtenstein herniorraphy after releasing graft-associated fibrosis. Repair of groin hernias in this complex setting requires careful surgical planning, preparation for potential vascular reconstruction and meticulous technique to avoid bowel injury in the face of a vascular conduit and mesh. PMID:28069880

  15. Flow diversion for complex intracranial aneurysms in young children.

    Science.gov (United States)

    Navarro, Ramon; Brown, Benjamin L; Beier, Alexandra; Ranalli, Nathan; Aldana, Philipp; Hanel, Ricardo A

    2015-03-01

    Pediatric intracranial aneurysms are exceedingly rare and account for less than 5% of all intracranial aneurysms. Open surgery to treat such aneurysms has been shown to be more durable than endovascular techniques, and durability of treatment is particularly important in the pediatric population. Over the past 2 decades, however, a marked shift in aneurysm treatment from open surgery toward endovascular procedures has occurred for adults. The authors describe their early experience in treating 3 unruptured pediatric brain aneurysms using the Pipeline embolization device (PED). The first patient, a girl with Majewski osteodysplastic primordial dwarfism Type II who was harboring multiple intracranial aneurysms, underwent two flow diversion procedures for a vertebrobasilar aneurysm and a supraclinoid internal carotid artery aneurysm. The second patient underwent PED placement on a previously coiled but enlarging posterior communicating artery aneurysm. All procedures were uneventful, with no postsurgical complications, and led to complete angiographic obliteration of the aneurysms. To the authors' knowledge, this is the first series of flow diversion procedures in children reported in the medical literature. While flow diversion is a new and relatively untested technology in children, outcomes in adults have been promising. For challenging lesions in the pediatric population, flow diversion may have a valuable role as a well-tolerated, safe treatment with durable results. Many issues remain to be addressed, such as the durability of flow diverters over a very long follow-up and vessel response to growth in the presence of an endoluminal device.

  16. Low mortality and morbidity after endovascular repair of ruptured aortic aneurism

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Balezantis, Tomas; Lindholt, Jes Sanddal

    2015-01-01

    INTRODUCTION: The objective of this study was to describe the implementation and to evaluate the short-term outcome of the first Danish experience with endovascular repair of ruptured abdominal aortic aneurysm (RAAA). METHODS: This was a historical prospective cohort study including all patients ......-operative mortality and morbidity of RAAA can probably be reduced by implementation of RAAA....... shortly after the procedure. In the group with open repair, seven patients (30.7%) died within 30 days. This yields a mortality of all patients treated for rupture at our institution of 19% compared with 32% in Denmark at large. CONCLUSION: Endovascular treatment of RAAA is feasible, and the overall post...

  17. Management of severe asymmetric pectus excavatum complicating aortic repair in a patient with Marfan's syndrome.

    Science.gov (United States)

    Yeung, Jonathan C; Marcuzzi, Danny; Peterson, Mark D; Ko, Michael A

    2016-05-01

    We describe the case of a 28-year old man with Marfan's syndrome and severe pectus excavatum who required an aortic root replacement for an ascending aortic aneurysm. There was a near-vertical angulation of the sternum that presented challenges with opening and exposure of the heart during aortic surgery. Furthermore, removal of the sternal retractor after aortic repair resulted in sudden loss of cardiac output. A Ravitch procedure was then performed to successfully close the chest without further cardiovascular compromise. We propose that patients with a severe pectus excavatum and mediastinal displacement seen on preoperative CT scanning should be considered for simultaneous, elective repair.

  18. Local Anesthesia in Open Inguinal Hernia Repair Improves Postoperative Quality of Life Compared to General Anesthesia: A Prospective, International Study.

    Science.gov (United States)

    Huntington, Ciara R; Wormer, Blair A; Cox, Tiffany C; Blair, Laurel J; Lincourt, Amy E; Augenstein, Vedra A; Heniford, B Todd

    2015-07-01

    The choice of general (GA) versus local anesthesia (LA) in open inguinal hernia repair (OIHR) has a substantial financial impact and may influence clinical outcomes. Our study compares postoperative quality of life (QOL) in patients undergoing OIHR under LA versus GA. A cooperative prospective study from centers in 10 countries was performed through the International Hernia Mesh Registry from 2007 to 2012. QOL was compared at one, six, 12, and 24 months for LA versus GA with univariate and multivariate analysis controlling for known confounding variables. Of 1128 patients who underwent OIHR, 585(52%) used GA and 533(48%) used LA. Most were male (92%) with unilateral (94%), primary (91%) repairs with a mean age 57 ± 16 years. There was no difference (P > 0.05) in age, gender, operative time, mesh size, length of stay, infection, recurrence, reoperation, or death. Multivariate analysis demonstrated significant QOL differences between groups: GA had higher odds of discomfort at one and six months [odds ratio (OR) 3.3, 2.0], movement limitation at one and six months (OR 3.5, 2.8), and mesh sensation at one and 12 months (OR 2.9, 1.8). Overall, patients undergoing OIHR under LA had improved postoperative QOL in the short and long term compared with GA.

  19. [Popliteal aneurysms].

    Science.gov (United States)

    Vaquero Morillo, F; Zorita Calvo, A; Fernández-Samos Gutiérrez, R; García Vázquez, J; Ortega Martín, J M; Fernández Morán, C

    1992-01-01

    We presented the review of 22 cases of popliteal aneurysms with a follow-time of three years. One case was a woman and 5 cases were bilaterals. The most part of cases begun as a latter acute ischemia. Sixteen cases were treated surgically, with a null rate of mortality, 2 amputations, 4 cases of residual intermittent claudication and 10 no-symptomatic patients, with present distal pulses. Etiology, clinical presentation, diagnosis, technics and results are presented and a comparison with other authors is made. Our experience support an interventionist attitude in cases of elderly nonsymptomatic patients, performed by internal way and saphenous vein substitution.

  20. Colovesical fistula following an open preperitoneal "Kugel" mesh repair of an inguinal hernia.

    Science.gov (United States)

    Barreto, S G; Schoemaker, D; Siddins, M; Wattchow, D

    2009-12-01

    Erosion of the "Kugel" mesh into intraperitoneal organs has not been previously reported in the medical literature. We report such an occurrence in a 54-year-old male, 4 years following a "Kugel" preperitoneal repair of a left-sided inguinal hernia. The patient presented with septicaemia, pneumaturia and left iliac fossa pain. His computed tomography (CT) scan indicated the presence of gas in the bladder and a thickened loop of sigmoid colon attached to the region of the dome of the bladder. Colonoscopy showed some scattered diverticula in the sigmoid colon but no tumour. On surgical exploration, the "Kugel" mesh was found to erode the sigmoid colon and the bladder wall, leading to a colovesical fistula. An anterior resection of the rectum with removal of the mesh with closure of the bladder wall defect was performed.

  1. Tension free open inguinal hernia repair using an innovative self gripping semi-resorbable mesh

    Directory of Open Access Journals (Sweden)

    Chastan Philippe

    2006-01-01

    Full Text Available Aims: Inguinal hernia repair according to Lichtenstein technique has become the most common procedure performed by general surgeons. Heavy weight polypropylene meshes have been reported to stimulate inflammatory reaction responsible for mesh shrinkage when scar tissue evolved. Additionally, some concerns remain regarding the relationship between chronic pain and mesh fixation technique. In order to reduce those drawbacks, we have developed a new mesh for anterior tension free inguinal hernia repair which exhibits self-gripping absorbable properties. Materials and Methods: 52 patients (69 hernias were prospectivly operated with this mesh (SOFRADIM-France made of low-weight isoelastic large pores knitted fabric which incorporated resorbable micro hooks that provides self gripping properties to the mesh during the first months post-implantation. The fixation of the mesh onto the tissues is significantly facilitated. The mesh is secured around the cord with a self gripping flap. After complete tissular ingrowth and resorption of the PLA hooks, the low-weight (40 g/m2 polypropylene mesh insures the long term wall reinforcement. Results: Peroperativly, no complication was reported, the mesh was easy to handle and to fix. Discharge was obtained at Day 1. No perioperative complication occurred, return to daily activities was obtained at Day 5.5. At one month, no neurological pain or other complications were described. Conclusions: Based on the first results of this clinical study, this unique concept of low density self gripping mesh should allows an efficient treatment of inguinal hernia. It should reduce postoperative complications and the extent of required suture fixation, making the procedure more reproducible

  2. Coagulation, inflammatory, and stress responses in a randomized comparison of open and laparoscopic repair of recurrent inguinal hernia

    DEFF Research Database (Denmark)

    Rahr, H B; Bendix, J; Ahlburg, P;

    2006-01-01

    with recurrent inguinal hernia were randomized to OR under local anesthesia (n = 30) or LR under general anesthesia (n = 31). The magnitude of the surgical trauma was assessed by measuring markers of coagulation (prothrombin fragment 1 + 2), endothelial activation (von Willebrand factor), inflammation......BACKGROUND: In previous comparisons of inflammatory and stress responses to open (OR) and laparoscopic (LR) hernia repair, all operations were performed under general anesthesia. Since local anesthesia is widely used for OR, a comparison of this approach with LR seemed relevant. METHODS: Patients...... in both groups, with the CRP increase being significantly greater in the OR group. The other markers did not increase significantly. CONCLUSION: The acute phase response was more pronounced after OR, even when this was done under local anesthesia. Both techniques seemed rather atraumatic....

  3. Endovascular repair of a juxtarenal saccular aneurysm using the Multilayer Flow Modulator: report of the first case performed in a Public Hospital in Brazil

    Directory of Open Access Journals (Sweden)

    Rodrigo Gibin Jaldin

    2014-09-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA, involving the exits of the renal and visceral arteries still constitutes a considerable challenge. Many different techniques have been developed over the years in attempts to surmount the difficulties presented by these cases. Techniques that have gained prominence include fenestrated or branched stents, methods involving parallel prostheses, such as the chimney, periscope and sandwich techniques, and, more recently, flow modulation with Multilayer stents. We describe a case of a complex juxtarenal saccular AAA with a high surgical risk, both according to cardiological assessment and because the patient had a difficult airway caused by a total laryngectomy for early stage laryngeal neoplasm. In view of the technical simplicity of using Multilayer stents, the presence of chronic obstructive aortoiliac disease, ostial stenosis of the renal artery and a small diameter suprarenal aorta, options involving fenestrated/branched stents and techniques involving parallel prostheses were ruled out, because of the need for multiple accesses. In view of the dilemma it presented, we describe this case as a therapeutic challenge and present the treatment option employed, which has been successful over the short term.

  4. LONG TERM OUTCOME AFTER OPEN INGUINAL HERNIA REPAIR BY CONTINOUS SUTURE VERSUS INTERRUPTED SUTURE TO FIX THE MESH

    Directory of Open Access Journals (Sweden)

    Kuldeep Raj

    2013-12-01

    Full Text Available ABSTRACT : BACK GROUND: Meshplasty is a must in adult patient. P ro lene mesh is widely used and is fixed with prolene suture as well. The aim of this study was to compare the quality of life and pain felt in postoperative phase for 2 years after open inguinal hernia repair by i nterrupted sutures versus continous sutures. METHODS: From Jan 2010 – Dec 2010 , 15 patients were operated using prolene mesh and this mesh was fixed with prolene 2’0’ in continous way starting at pubic tubercle and continues along inguinal ligament beyond deep inguinal r ing and then lateral to deep inguinal ring and above it along conjoint tendon and ends at the pubic tubercle with only single knot , and were compared with 15 patients who underwent same procedure using prolene mesh fixed with p rolene suture but in interrupted way and this creates a lot of knots ( 10 - 12 Av erage . Patients were examined and followed in OPD for 2 years. RESULTS : In the long run the patients treated with continous suture were having comparatively better qua lity of life with less pain and less foreign body sensation of mesh and knots & knots were not felt percutaneously, where as in routine procedure patients were complaining of painful sensation due to pressing of knots in subcutaneous space. CONCLUSION : In this study the quality of life in open hernia repair with prolene suture using continous suture technique versus interrupted suture technique is definitely better , less pain ful and feeling less foreign body sensation.

  5. Randomized Clinical Trial of Laparoscopic Versus Open Repair of the Perforated Peptic Ulcer: The LAMA Trial

    NARCIS (Netherlands)

    M.J.O.E. Bertleff; J.A. Halm; W.A. Bemelman; A.C. van der Ham; E. van der Harst; H.I. Oei; J.F. Smulders; E.W. Steyerberg; J.F. Lange

    2009-01-01

    Laparoscopic surgery has become popular during the last decade, mainly because it is associated with fewer postoperative complications than the conventional open approach. It remains unclear, however, if this benefit is observed after laparoscopic correction of perforated peptic ulcer (PPU). The goa

  6. Randomized clinical trial of laparoscopic versus open repair of the perforated peptic ulcer: The LAMA trial

    NARCIS (Netherlands)

    M.J.O.E. Bertleff (Marietta); J.A. Halm (Jens); W.A. Bemelman (Willem); A.C. van der Ham (Arie); E. van der Harst (Erwin); H.I. Oei (Hok); J.F. Smulders; E.W. Steyerberg (Ewout); J.F. Lange (Johan)

    2009-01-01

    textabstractBackground: Laparoscopic surgery has become popular during the last decade, mainly because it is associated with fewer postoperative complications than the conventional open approach. It remains unclear, however, if this benefit is observed after laparoscopic correction of perforated pep

  7. Open and laparo-endoscopic repair of incarcerated abdominal wall hernias by the use of biological and biosynthetic meshes

    Directory of Open Access Journals (Sweden)

    René H Fortelny

    2016-02-01

    Full Text Available Introduction: Although recently published guidelines recommend against the use of synthetic non-absorbable materials in cases of potentially contaminated or contaminated surgical fields due to the increased risk of infection [1, 2], the use of bio-prosthetic meshes for abdominal wall or ventral hernia repair is still controversially discussed in such cases. Bio-prosthetic meshes have been recommended due to less susceptibility for infection and the decreased risk of subsequent mesh explantation. The purpose of this review is to elucidate if there are any indications for the use of biological and biosynthetic meshes in incarcerated abdominal wall hernias based on the recently published literature.Methods: A literature search of the Medline database using the PubMed search engine, using the keywords returned 486 articles up to June 2015. The full text of 486 articles was assessed and 13 relevant papers were identified including 5 retrospective case cohort studies, 2 case controlled studies, 6 case series.Results: The results of Franklin et al [23, 24, 25] included the highest number of biological mesh repairs (Surgisis® by laparoscopic IPOM in infected fields which demonstrated a very low incidence of infection and recurrence (0,7% and 5,2%. Han et al [26] reported in his retrospective study the highest number of treated patients due to incarcerated hernias by open approach using acellular dermal matrix (ADM® with very low rate of infection as well as recurrences (1,6% and 15,9. Both studies achieved acceptable outcome in a follow up of at least 3,5 years compared to the use of synthetic mesh in this high-risk population [3]Conclusion:Currently there is a very limited evidence for the use of biological and biosynthetic meshes in strangulated hernias in either open or laparo-endoscopic repair. Finally, there is an urgent need to start with randomized controlled comparative trials as well as to support registries with data to achieve more

  8. Comparison of the Effects of Laparoscopic and Open Repair Techniques on Postoperative Pain and Analgesic Consumption in Pediatric Unilateral Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Ferda Yılmaz İnal

    2014-06-01

    Full Text Available Aim: Although laparoscopic inguinal hernia (IH repair in adults is widely accepted, its advantages in pediatric age group are questionable. We aimed to compare the effects of open inguinal hernia repair and laparoscopic inguinal hernia repair on length of anaesthesia, postoperative pain and analgesic consumption in boys who underwent unilateral inguinal hernia repair. Methods: Forty patients aged between 7 and 14 years who underwent open and laparoscopic inguinal hernia repair were included in this study. The patients were randomly divided into two groups: unilateral open inguinal hernia repair group (OR n=20 and unilateral laparoscopic inguinal hernia repair group (LR n=20. All patients underwent general anesthesia. The duration of anaesthesia and the duration of surgery were recorded. The Patient Controlled Analgesia (PCA device was set at a 0.01 mg/kg bolus dose, 10 minutes lockout interval and 4 hour limit of 4 mg morphine. The patients, who received morphine PCA for 24 hours postoperatively, were monitored with continuous oximetry. The Visual Analogue Scale (VAS was used to measure pain (0 cm: no pain, 10 cm: worst possible pain. We recorded the side effects of morphine, such as respiratory depression, nausea, vomiting, urinary retention, pruritus. SpO2 level and Ramsay Sedation Scale (RSS, Numerical Rating Scale (NRS, and Visual Analogue Scale (VAS scores at intervals 1, 2, 4, 12, 24 hours as well as amount of analgesics consumed and number of requests within 24 hours postoperatively were recorded. Time to first walking was recorded. Results: In group OR, the mean duration of anaesthesia and surgery were 39.85 minutes and 28.85 minutes, respectively. In group LR, the mean duration of anaesthesia and surgery were 26.11 and 20.53 minutes, respectively. VAS scores and time to first walking were similar in both groups. There was no significant difference in amount of analgesics consumed and number of request between the two groups. In group OR

  9. Hybrid Endovascular Aorta Repair with Simultaneous Supra-aortic Branch or Iliac Branch Revascularization

    Institute of Scientific and Technical Information of China (English)

    Yue-hong Zheng; Nim Choi; Hong-ru Deng; CU Kouk; Kun Yu; Furtado Rui

    2009-01-01

    Objective To describe a hybrid endovascular procedure for aorta repair with different kinds of bypass followed by concomitant placement of stent graft in the aorta.Methods From June 2007 to May 2008,5 consecutive patients who presented with aortic aneurysm or dissection were treated with a new hybrid aorta repair technique.Complete surgical rerouting of supra-aortic vessels was simultaneously created by endovascular repair of aortic arch aneurysm with stent graft.Hybrid left carotid-subclavian bypass with stent graft deployment covering the ostium of the left subclavian artery was performed in a Debakey type Ⅲ aortic dissection case.The supra-aortic branch was revascularized in 2 cases from ascending aorta to bilateral common carotid arteries using a 16-8 mm bifurcated graft,then total aortic arch and descending artery was occluded with stent-graft.The left carotid artery to the left subclavian artery bypass was created in 1 case,followed by stent-graft deployment.Two cases of infrarenal abdominal aortic aneurysm underwent left external iliac artery to left internal iliac artery bypass by a retroperineal route,then hybrid procedure was performed with bifurcated stent-graft.All stent grafts were deployed via a retrograde femoral artery approach in 5 patients.Results Technical success with complete aneurysmal exclusion was achieved in all patients.There was no incidence of endoleak.During a follow-up period of 2 to 10 months,documented perioperative neurologic events did not occur in all patients.One patient suffered from adult respiratory distress syndrome.After received tracheostomy,he recovered later.There was one death resulting from a postoperative myocardial infarction.Conclusion Hybrid arch repair provides an alternative therapy to patients otherwise considered prohibitively high risk for traditional open arch and thoracoabdominal aorta repair.

  10. Identification of predictive CT angiographic factors in the development of high-risk type 2 endoleaks after endovascular aneurysm repair in patients with infrarenal aortic aneurysms; Identifikation praediktiver CT-angiographischer Faktoren fuer die Entstehung eines Hochrisiko Typ-2 Endoleaks nach endovaskulaerem Aortenrepair bei Patienten mit infrarenalen Bauchaortenaneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Loewenthal, D.; Herzog, L.; Rogits, B.; Bulla, K.; Pech, M.; Ricke, J.; Dudeck, O. [Magdeburg Univ. (Germany). Radiology and Nuclear Medicine; Weston, S. [Magdeburg Univ. (Germany). Biometry and Medical Informatics; Meyer, F.; Halloul, Z. [Magdeburg Univ. (Germany). General, Visceral and Vascular Surgery

    2015-01-15

    An extensive analysis of the value of computed tomography (CT) parameters as potential predictors of the clinical outcome of type 2 endoleaks after endovascular aortic aneurysm repair (EVAR). Initial CT scans of 130 patients with abdominal aortic aneurysms (AAAs) were retrospectively reviewed. On the basis of postoperative CT scans and angiographies, patients were stratified into a low-risk group (LRG; without or transient type 2 endoleak; n = 80) and a high-risk group (HRG, persistent type 2 endoleak or need for reintervention; n = 50). Statistical analysis comprised a univariate and multivariate analysis. Anatomical, thrombus-specific, as well as aortic side branch parameters were assessed on the initial CT scan. Of all anatomical parameters, the diameter of the immediate infrarenal aorta was significantly different in the univariate analysis (LRG 22.4 ± 3.8 mm; HRG 23.6 ± 2.5 mm; p = 0.03). The investigation of the thrombus-specific parameters showed a trend towards statistical significance for the relative thrombus load (LRG 31.7 ± 18.0 %; HRG 25.3 ± 17.5 %; p = 0.09). Assessment of aortic side branches revealed only for the univariate analysis significant differences in the patency of the inferior mesenteric artery (LRG 71.3 %; HRG 92.0 %; p = 0.003) and their diameter (LRG 3.3 ± 0.7 mm; HRG 3.8 ± 0.9 mm; p = 0.004). In contrast, the number of lumbar arteries (LAs; LRG 2.7 ± 1.4; HRG 3.6 ± 1.2; univariate: p = 0.01; multivariate: p = 0.006) as well as their diameter (LRG 2.1 ± 0.4 mm; HRG 2.4 ± 0.4 mm; univariate: p < 0.001; multivariate: p = 0.006) were highly significantly associated with the development of type 2 endoleaks of the HRG. The most important predictive factors for the development of high-risk type 2 endoleaks were mainly the number and the diameter of the LAs which perfused the AAA.

  11. Dual-energy CT in the follow-up after endovascular abdominal aortic aneurysm repair; Dual-Energy CT zur postoperativen Langzeitkontrolle nach endovaskulaer therapierten abdominellen Aortenaneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Braegelmann, A.; Heindel, W.; Seifarth, H. [Universitaetsklinikum Muenster (Germany). Inst. fuer Klinische Radiologie; Bunck, A.; Maintz, D. [Universitaetsklinikum Muenster (Germany). Inst. fuer Klinische Radiologie; Universitaetsklinikum Koeln (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Donas, K.; Kasprzak, B. [Universitaetsklinikum Muenster (Germany). Klinik fuer Vaskulaere und Endovaskulaere Chirurgie

    2013-04-15

    This study investigates the dual-energy procedure for postoperative CT follow-up scans after endovascularly treated abdominal aortic aneurysms. The procedure is analyzed with respect to its sensitivity and specificity as well as the associated radiation exposure. 51 examinations were carried out on 47 patients between February 2009 and March 2010. For each patient, a non-enhanced, an arterial and a venous scan were conducted, the latter two using the dual-energy technology. Virtual images for the non-enhanced phase were reconstructed from the data taken in the venous phase. Protocol A, the reference standard, consisted of non-enhanced images and images of the arterial and venous phase. In protocol B, standard non-enhanced images were replaced by the reconstructed virtual non-enhanced images. Protocol C consisted only of virtual non-enhanced and 80 kV images taken during the venous phase. All data was anonymized and evaluated by two independent radiologists. For protocol C, sensitivity, specificity, negative and positive predictive values were computed. The effective radiation dosage was determined for each scan. All endoleaks identified in protocol A were found using protocols B and C. For protocol C, the sensitivity and negative predictive value were 100 %, the specificity was 94.1 %, and the positive predictive value was 89.5 %. Compared to protocol A, protocol C reduces the radiation exposure by 62.45 %. A scan protocol consisting of virtual non-enhanced images as well as 80 kV images taken during the venous phase was found to be a reliable alternative method for diagnosing endoleaks, while reducing the radiation exposure by 62.45 %. (orig.)

  12. Abdominal aortic aneurysm

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000162.htm Abdominal aortic aneurysm To use the sharing features on this page, ... blood to the abdomen, pelvis, and legs. An abdominal aortic aneurysm occurs when an area of the aorta becomes ...

  13. [False aneurysm on dacron prosthesis, 20 years after aortofemoral bypass].

    Science.gov (United States)

    Illuminati, G; Bertagni, A; Nasti, A G; Montesano, G

    2001-10-01

    A 85-year-old male developed a false, non septic, non anastomotic aneurysm, 20 years after right aorto-femoral Dacron grafting for claudication. On account of the proximity to the femoral anastomosis, and the association with a profunda femoris stenosis, a conventional surgical repair was preferred to an endovascular treatment. The patient underwent a successful aneurysm resection followed by PTFE interposition between the primary graft and the profunda femoris artery, with uneventful recovery.

  14. Paediatric intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    A A Wani

    2006-01-01

    Full Text Available Intracranial aneurysms in childhood account for 1-2% of intracranial aneurysms.[1],[2] These aneurysms have unique characteristics that make them different from those in adults. These differences are evident in their epidemiology, location, clinical spectrum, association with trauma and infection, complications and outcome.

  15. Unruptured intracranial aneurysms

    NARCIS (Netherlands)

    Backes, Daan

    2016-01-01

    Rupture of an intracranial aneurysm results in aneurysmal subarachnoid hemorrhage (SAH), a subtype of stroke with an incidence of 9 per 100,000 person-years and a case-fatality around 35%. In order to prevent SAH, patients with unruptured intracranial aneurysms can be treated by neurosurgical or end

  16. Self-Expandable Stent for Repairing Coarctation of the Left-Circumferential Aortic Arch with Right-sided Descending Aorta and Aberrant Right Subclavian Artery with Kommerell's Aneurysm.

    Science.gov (United States)

    Khajali, Zahra; Sanati, Hamid Reza; Pouraliakbar, Hamidreza; Mohebbi, Bahram; Aeinfar, Kamran; Zolfaghari, Reza

    2017-01-01

    Endovascular treatment offers a great advantage in the management of main arteries stenoses. However, simultaneous presence of a group of anomalies may complicate the situation. Here we present a case of 21-year-old man with aortic coarctation. Radiographic imaging and angiography demonstrated aortic coarctation of the left-circumferential aortic arch, right-sided descending aorta, and Kommerell's diverticulum at the origin of right subclavian artery. These anomalies have rarely been reported to concurrently exist in the same case and the treatment is challenging. Percutaneous treatment for repair of aortic coarctation was successfully performed with deployment of self-expanding nitinol stents. Follow-up demonstrated the correction of blood pressure and improvement of the symptoms. It appears that deployment of self-expandable nitinol stents present a viable option for the management of coarcted aorta in patients having all or some of these anomalies together.

  17. Turbine repair process, repaired coating, and repaired turbine component

    Energy Technology Data Exchange (ETDEWEB)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  18. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  19. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  20. Premilinary Observation of Sarpogrelate Hydrochloride on Prevention and Treatment for Gluteal and Limb Ischemia Following Endovascular Repair of Abdominal Aortic Aneurysm%盐酸沙格雷酯在腹主动脉瘤腔内修复术后防治臀肌和下肢缺血的初步观察

    Institute of Scientific and Technical Information of China (English)

    黄斌; 赵纪春; 马玉奎; 卢武胜; 杨轶; 袁丁

    2012-01-01

    Objective To observe the effects of sarpogrelate hydrochloride in prevention and treatment for ischemia of gluteal and limb following endovascular repair of abdominal aortic aneurysm (EVAR) . Methods Clinical data were analyzed in 174 patients with abdominal aortic aneurysm (AAA) who underwent EVAR from January 2006 to January 2011. The patients' mean age was (71. 8 + 8. 2) years old (male: 148 cases, female: 26 cases) . The diameter of abdominal aortic aneurysm was (55. 2+12. 9) mm. AAA involving common iliac artery was in 52 (29.9%) patients. Bifurcated endografts and aorto-uni-iliac (AUI) endografts with crossover bypass were used in 169 patients (97. 1%) and 5 patients (2. 9%) , respectively. Sarpogrelate hydrochloride were used in 39 patients with gluteal and limb ischemia due to exclusion of bilateral and unilateral internal iliac arteries among 174 patients. Sarpogrelate hydrochloride, 100 mg, three times daily, was taken for 2-4 weeks. Symptoms of gluteal and limb ischemia were followed-up. Results All of patients with AAA was repaired by EVAR successfully and no conversion to open repair. General anesthesia (50. 6% (88/174)], epidural anesthesia (30. 0% (52/174)], and local anesthesia (19. 5% (34/174)] were used. Blood loss was (125. 2+43. 1) ml and no blood transfusion during operation. Operative time was (145. 5 + 38. 7) min, ICU stay time was (14. 7+5. 2) h, and postoperative fasting time was (7. 2+4. 3) h. The duration of postoperative hos-pital stay was (9. 1 ±2. 7) d. The perioperative complication rate was 12. 6% (22/174) . The 30-day mortality rate was 1. 1% (2/174) . Gluteal and limb claudication occurred in 2 paients and 5 patients respectively among 29 patients with EVAR due to exclusion of unilateral internal iliac artery, intermittent claudication distance was 100-200 meters. Gluteal muscle pain and limb claudication for less than 200 meters occurred in 4 patients due to exclusion of bilateral internal iliac artery. The symptoms were relieved

  1. Endovascular treatment of coarctation and related aneurysms.

    Science.gov (United States)

    Galiñanes, E L; Krajcer, Z

    2014-06-11

    Today,surgical repair has almost doubled the 30year survival rate in patients with coarctation of the aorta (CoA), and 72% to 98% of patients now reach adulthood. Possible late complications include malignant hypertension, left ventricular dysfunction, aortic valve dysfunction, recurrent CoA, and aneurysm formation with risk of rupture. Treating postoperative CoA-related aneurysms with observation alone is associated with a mortality rate of 36%, compared with 9% for surgical repair. Even in the best surgeons' hands, aortic surgery has associated complications, and the complexity of reoperative surgery makes the risks substantially greater. For patients with CoA-related aneurysm, endovascular treatment constitutes a good alternative to reoperative surgery because it poses a lower risk of morbidity and mortality. Implanting an endograft has been shown to be successful in treating CoA and related aneurysms, producing excellent intermediate outcomes and minimal morbidity and mortality. Despite evidence that using covered stents improves outcomes, the superiority of any particular stent type has yet to be established. With a variety of endografts available, the decision of which stent to use depends on anatomy, availability, and operator preference.

  2. Screening for aortic aneurysm after treatment of coarctation.

    Science.gov (United States)

    Hoffman, James L; Gray, Robert G; LuAnn Minich, L; Wilkinson, Stephen E; Heywood, Mason; Edwards, Reggie; Weng, Hsin Ti; Su, Jason T

    2014-01-01

    Isolated coarctation of the aorta (CoA) occurs in 6-8 % of patients with congenital heart disease. After successful relief of obstruction, patients remain at risk for aortic aneurysm formation at the site of the repair. We sought to determine the diagnostic utility of echocardiography compared with advanced arch imaging (AAI) in diagnosing aortic aneurysms in pediatric patients after CoA repair. The Congenital Heart Databases from 1996 and 2009 were reviewed. All patients treated for CoA who had AAI defined by cardiac magnetic resonance imaging (MRI), computed tomography (CT), or catheterization were identified. Data collected included the following: type, timing, and number of interventions, presence and time to aneurysm diagnosis, and mortality. Patients were subdivided into surgical and catheterization groups for analysis. Seven hundred and fifty-nine patients underwent treatment for CoA during the study period. Three hundred and ninety-nine patients had at least one AAI. Aneurysms were diagnosed by AAI in 28 of 399 patients at a mean of 10 ± 8.4 years after treatment. Echocardiography reports were available for 380 of 399 patients with AAI. The sensitivity of echocardiography for detecting aneurysms was 24 %. The prevalence of aneurysms was significantly greater in the catheterization group (p Aneurysm was also diagnosed earlier in the catheterization group compared with the surgery group (p = 0.02). Multivariate analysis showed a significantly increased risk of aneurysm diagnosis in patients in the catheterization subgroup and in patients requiring more than three procedures. Aortic aneurysms continue to be an important complication after CoA repair. Although serial echocardiograms are the test of choice for following-up most congenital cardiac lesions in pediatrics, our data show that echocardiography is inadequate for the detection of aneurysms after CoA repair. Because the time to aneurysm diagnosis was shorter and the risk greater in the

  3. Mortalidade relacionada ao tratamento endovascular do aneurisma da aorta abdominal com o uso dos modelos revisados Procedure-related mortality of endovascular abdominal aortic aneurysm repair using revised reporting standards

    Directory of Open Access Journals (Sweden)

    Gosen Gabriel Konig

    2007-03-01

    Full Text Available OBJETIVO: O objetivo do estudo foi avaliar a definição da mortalidade relacionada ao procedimento após tratamento endovascular do aneurisma de aorta abdominal (EVAR como definido pelo Committee for Standardized Reporting Practices in Vascular Surgery. MÉTODO: Dados de pacientes com aneurisma de aorta abdominal foram analisados do banco de dados EUROSTAR. Os pacientes foram submetidos ao EVAR entre junho de 1996 a fevereiro de 2004 e foram estudados retrospectivamente. A probabilidade explicita da causa de morte foi registrada. O intervalo entre a operação, alta hospitalar ou intervenção secundária até a morte foi registrado. RESULTADOS: De um total de 5612 pacientes, 589 (10,5% faleceram após o EVAR em acompanhamento total e qualquer causa de morte foi inclusa. Cento e quarenta e um pacientes (12,5% morreram devido a causa relacionada ao aneurisma, sendo que 28 (4,8% foram rupturas, 25 (4,2% infecções do implante e 88 (14,9% foram pacientes que morreram num prazo de 30 dias após o procedimento inicial (definição atualmente utilizada, também conhecido como resultado clínico a curto prazo. Além disso, 25 pacientes faleceram após 30 dias, mas continuavam ainda hospitalizados (ou transferidos a home-care para reavaliação posterior, ou necessitaram intervenção secundária. Levando em conta a duração da admissão ao hospital e a mortalidade imediata após o procedimento relacionada a intervenções secundárias, 49 mortes tardias também podem ser relacionadas ao EVAR. CONCLUSÃO: Morte tardia compõe uma proporção considerável da mortalidade relacionada ao EVAR dentro do tempo de análise revisado.OBJECTIVE: The aim of this study was to evaluate the definition of Procedure-related mortality after endovascular aneurysm repair (EVAR as defined by the Committee for Standardized Reporting Practices in Vascular Surgery. METHODS: Data on patients with an AAA were taken from the EUROSTAR database. The patients underwent EVAR

  4. 开放式肠造口旁疝手术修补法40例分析%Open repair for parastomal hernia: report of 40 cases

    Institute of Scientific and Technical Information of China (English)

    陈革; 唐健雄; 黄磊; 蔡昭; 袁祖荣

    2007-01-01

    Objective To study different procedures of open hernia repair for parastomal hernias. Methods We retrospetively analysed 30 patients with parastomal hernia who had been treated by open hernia repair at our hospital from june 2002 to june 2007. Operative methods, post-operative complications, post-operative hospitalization, and recurrence of hernia were studied. Results No-relocation intraperitonialention parastomal hernia repair has one recurrence. Relocated intraperitonial parastomal hernia repair was performed in one patient. Relocated intraperitonial parastomal hernia repair was done in one patient with seroma. No relocated intraperitonial parastomal hernia repair was done in two patients with delayed incision, nor intestinal erosion and obstruction. Hospital stay after operation with no-relocation intraperitonial parastomal hernia repair was 10~14 days. Hospitalization after operation with relocation intraperitonial parastomal hernia repair was18~21 days. Conclusion The results of hernia repair for parastomal hernias are promising.%目的 分析开放式肠造口旁疝的手术修补方法存在的问题.方法 对2002年6月至2007年6月30例肠造口旁疝患者的手术方式、术后并发症、住院时间、复发情况进行回顾分析.结果 原位腹腔内造口疝修补术和移位造口疝修补术各有1例复发.移位造口疝修补术后有1例皮下积液.原位腹膜前造口疝修补术有2例伤口愈合不良.未发生肠坏死及肠梗阻等术后并发症.原位腹腔内和腹膜前造口疝修补术后住院时间10~14 d,移位造口疝修补术后住院时间18~21 d.结论 肠造口旁疝修补术的方法还有待进一步改进.

  5. Endothelial cell proliferation in swine experimental aneurysm after coil embolization.

    Directory of Open Access Journals (Sweden)

    Yumiko Mitome-Mishima

    Full Text Available After coil embolization, recanalization in cerebral aneurysms adversely influences long-term prognosis. Proliferation of endothelial cells on the coil surface may reduce the incidence of recanalization and further improve outcomes after coil embolization. We aimed to map the expression of proliferating tissue over the aneurysmal orifice and define the temporal profile of tissue growth in a swine experimental aneurysm model. We compared the outcomes after spontaneous thrombosis with those of coil embolization using histological and morphological techniques. In aneurysms that we not coiled, spontaneous thrombosis was observed, and weak, easily detachable proliferating tissue was evident in the aneurysmal neck. In contrast, in the coil embolization group, histological analysis showed endothelial-like cells lining the aneurysmal opening. Moreover, immunohistochemical and morphological analysis suggested that these cells were immature endothelial cells. Our results indicated the existence of endothelial cell proliferation 1 week after coil embolization and showed immature endothelial cells in septal tissue between the systemic circulation and the aneurysm. These findings suggest that endothelial cells are lead to and proliferate in the former aneurysmal orifice. This is the first examination to evaluate the temporal change of proliferating tissue in a swine experimental aneurysm model.

  6. The role of base excision repair in the development of primary open angle glaucoma in the Polish population

    Energy Technology Data Exchange (ETDEWEB)

    Cuchra, Magda; Markiewicz, Lukasz; Mucha, Bartosz [Department of Clinical Chemistry and Biochemistry, Medical University of Lodz (Poland); Pytel, Dariusz [The Abramson Family Cancer Research Institute, Department of Cancer Biology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104 (United States); Department of Biochemistry and Molecular Biology, Hollings Cancer Center, Medical University of South Carolina, Charleston, SC 29425 (United States); Szymanek, Katarzyna [Department of Ophthalmology, Medical University of Warsaw, SPKSO Hospital, Warsaw (Poland); Szemraj, Janusz [Department of Medical Biochemistry, Medical University of Lodz, Lodz (Poland); Szaflik, Jerzy; Szaflik, Jacek P. [Department of Ophthalmology, Medical University of Warsaw, SPKSO Hospital, Warsaw (Poland); Majsterek, Ireneusz, E-mail: ireneusz.majsterek@umed.lodz.pl [Department of Clinical Chemistry and Biochemistry, Medical University of Lodz (Poland)

    2015-08-15

    Highlights: • We suggested the association of XRCC1 gene with the increase risk of POAG development. • We indicated the association of clinical factor and XRCC1, MUTYH, ADPRT and APE1 genes with POAG progression. • We postulated the increase level of oxidative DNA damage in group of patients with POAG in relation to healthy controls. • We suggested the slightly decrease ability to repair of oxidative DNA damage. • This is the first data that showed the role of BER mechanism in POAG pathogenesis. - Abstract: Glaucoma is a leading cause of irreversible blindness in developing countries. Previous data have shown that progressive loss of human TM cells may be connected with chronic exposure to oxidative stress. This hypothesis may suggest a role of the base excision repair (BER) pathway of oxidative DNA damage in primary open angle glaucoma (POAG) patients. The aim of our study was to evaluate an association of BER gene polymorphism with a risk of POAG. Moreover, an association of clinical parameters was examined including cup disk ratio (c/d), rim area (RA) and retinal nerve fiber layer (RNFL) with glaucoma progression according to BER gene polymorphisms. Our research included 412 patients with POAG and 454 healthy controls. Gene polymorphisms were analyzed by PCR-RFLP. Heidelberg Retinal Tomography (HRT) clinical parameters were also analyzed. The 399Arg/Gln genotype of the XRCC1 gene (OR 1.38; 95% CI 1.02–1.89 p = 0.03) was associated with an increased risk of POAG occurrence. It was indicated that the 399Gln/Gln XRCC1 genotype might increase the risk of POAG progression according to the c/d ratio (OR 1.67; 95% CI 1.07–2.61 P = 0.02) clinical parameter. Moreover, the association of VF factor with 148Asp/Glu of APE1 genotype distribution and POAG progression (OR 2.25; 95% CI 1.30–3.89) was also found. Additionally, the analysis of the 324Gln/His MUTYH polymorphism gene distribution in the patient group according to RNFL factor showed that it might

  7. Rescue microsurgery with bypass and stent removal following Pipeline treatment of a giant internal carotid artery terminus aneurysm.

    Science.gov (United States)

    Bowers, Christian A; Taussky, Philip; Park, Min S; Neil, Jayson A; Couldwell, William T

    2015-12-01

    We report the microsurgical rescue and removal of a Pipeline stent embolization of a giant internal carotid artery terminus aneurysm. After the initial placement of a Pipeline Embolization Device (PED), it migrated proximally to the cavernous carotid with the distal end free in the middle of the aneurysm, resulting in only partial aneurysm neck coverage. The patient underwent microsurgical rescue with trapping, bypass, and opening of the aneurysm with PED removal. The vessel remained patent in the proximal segment previously covered by the Pipeline stent. Microsurgical rescue for definitive aneurysm treatment with PED removal can be safe and effective for aneurysms unsuccessfully treated with PED.

  8. TEVAR for Flash Pulmonary Edema Secondary to Thoracic Aortic Aneurysm to Pulmonary Artery Fistula.

    Science.gov (United States)

    Bornak, Arash; Baqai, Atif; Li, Xiaoyi; Rey, Jorge; Tashiro, Jun; Velazquez, Omaida C

    2016-01-01

    Enlarging aneurysms in the thoracic aorta frequently remain asymptomatic. Fistulization of thoracic aortic aneurysms (TAA) to adjacent structures or the presence of a patent ductus arteriosus and TAA may lead to irreversible cardiopulmonary sequelae. This article reports on a large aneurysm of the thoracic aorta with communication to the pulmonary artery causing pulmonary edema and cardiorespiratory failure. The communication was ultimately closed after thoracic endovascular aortic aneurysm repair allowing rapid symptom resolution. Early diagnosis and closure of such communication in the presence of TAA are critical for prevention of permanent cardiopulmonary damage.

  9. Long-Term Results of Mini-Open Repair Technique in the Treatment of Acute Achilles Tendon Rupture: A Prospective Study.

    Science.gov (United States)

    Taşatan, Ersin; Emre, Tuluhan Yunus; Demircioğlu, Demet Tekdöş; Demiralp, Bahtiyar; Kırdemir, Vecihi

    2016-01-01

    An ideal surgical treatment of acute Achilles tendon rupture includes restoring the original length of the tendon, minimizing possible adhesions with the surrounding tissues, minimizing the risk of repeat rupture, alleviating wound problems, and providing an acceptable cosmetic outcome. In the mini-open repair technique, unlike the percutaneous repair technique, the quality of the tenodesis can be visualized without disturbing the healing potential of the surrounding tissues, thus minimizing wound problems. The purpose of the present study was to assess the long-term results of the mini-open repair technique in patients with acute Achilles tendon rupture. A total of 20 consecutive patients with acute Achilles tendon rupture, admitted to our inpatient clinic from October 2003 to March 2008, were included in the present study. The patients underwent Achilles tenodesis with the mini-open repair technique, and each patient was followed up for 5 years. The study was completed in April 2013. The surgical procedure was performed with the assistance of a device designed in our orthosis laboratories, similarly to that defined by Assal et al. Of the 20 patients, 18 were male and 2 were female. Their mean age was 39.3 (range 21 to 55) years. The Achilles tendon rupture was located on the left side in 15 patients (75%) and on the right side in 5 patients (25%). The mean follow-up duration was 58.5 (range 18 to 60) months and no complications occurred during the follow-up period, including repeat rupture, wound site infection, and sural nerve injury. The mean American Orthopaedic Foot and Ankle Society scale score for the patients was 99.2 (range 94 to 100) points at the final follow-up visit. All our patients were able to return to work and sporting activities. According to the Trillat scores, the outcome was excellent in 19 patients and good in 1 patient at the 18th postoperative month. No complaint, such as pain or loss of function, that might have a negative effect on the

  10. The role of base excision repair in the development of primary open angle glaucoma in the Polish population.

    Science.gov (United States)

    Cuchra, Magda; Markiewicz, Lukasz; Mucha, Bartosz; Pytel, Dariusz; Szymanek, Katarzyna; Szemraj, Janusz; Szaflik, Jerzy; Szaflik, Jacek P; Majsterek, Ireneusz

    2015-08-01

    Glaucoma is a leading cause of irreversible blindness in developing countries. Previous data have shown that progressive loss of human TM cells may be connected with chronic exposure to oxidative stress. This hypothesis may suggest a role of the base excision repair (BER) pathway of oxidative DNA damage in primary open angle glaucoma (POAG) patients. The aim of our study was to evaluate an association of BER gene polymorphism with a risk of POAG. Moreover, an association of clinical parameters was examined including cup disk ratio (c/d), rim area (RA) and retinal nerve fiber layer (RNFL) with glaucoma progression according to BER gene polymorphisms. Our research included 412 patients with POAG and 454 healthy controls. Gene polymorphisms were analyzed by PCR-RFLP. Heidelberg Retinal Tomography (HRT) clinical parameters were also analyzed. The 399 Arg/Gln genotype of the XRCC1 gene (OR 1.38; 95% CI 1.02-1.89 p = 0.03) was associated with an increased risk of POAG occurrence. It was indicated that the 399 Gln/Gln XRCC1 genotype might increase the risk of POAG progression according to the c/d ratio (OR 1.67; 95% CI 1.07-2.61 P = 0.02) clinical parameter. Moreover, the association of VF factor with 148 Asp/Glu of APE1 genotype distribution and POAG progression (OR 2.25; 95% CI 1.30-3.89) was also found. Additionally, the analysis of the 324 Gln/His MUTYH polymorphism gene distribution in the patient group according to RNFL factor showed that it might decrease the progression of POAG (OR 0.47; 95% CI 0.30-0.82 P = 0.005). We suggest that the 399 Arg/Gln polymorphism of the XRCC1 gene may serve as a predictive risk factor of POAG.

  11. Preperitoneal sutureless mesh repair of inguinal hernia by open inguinal approach using inferior epigastric vessel complex as landmark: A tertiary care centre experience

    Directory of Open Access Journals (Sweden)

    Inderjit Chawla

    2014-01-01

    Full Text Available Introduction: The study is a clinical trial done on patients with inguinal hernia, who were treated by open preperitoneal sutureless mesh repair, using inferior epigastric vessel complex as landmark. Aim: To study the postoperative complications and recurrence rates associated with the open preperitoneal sutureless mesh repair. Materials and Methods: Total 100 patients of inguinal hernia were recruited in this clinical trial from January 2009 to December 2012. Those with bilateral inguinal hernia or recurrent hernias were excluded from the study. Results: The average time taken to complete the surgery was 42.2 minutes and the average hospital stay was 2.5 days. Post-surgery, at a median follow-up period of 2 years, only 2 patients had seroma formation. Visual analog scale pain scores of 4 and 6 were seen in 60% and 40% cases, respectively. No recurrences were encountered post-surgery in any of the case till the last follow-up. Conclusion: This procedure was found to have fewer complications and was less time-consuming as compared to the other conventional open hernia repairs.

  12. Mesh fixation methods in open inguinal hernia repair: a protocol for network meta-analysis and trial sequential analysis of randomised controlled trials

    Science.gov (United States)

    Ge, Long; Tian, Jin-hui; Li, Lun; Wang, Quan; Yang, Ke-hu

    2015-01-01

    Introduction Randomised clinical trials (RCTs) have been used to compare and evaluate different types of mesh fixation usually employed to repair open inguinal hernia. However, there is no consensus among surgeons on the best type of mesh fixation method to obtain optimal results. The choice often depends on surgeons’ personal preference. This study aims to compare different types of mesh fixation methods to repair open inguinal hernias and their role in the incidences of chronic groin pain, risk of hernia recurrence, complications, operative time, length of hospital stay and postoperative pain, using Bayesian network meta-analysis and trial sequential analysis of RCTs. Methods and analysis A systematic search will be performed using PubMed, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), Chinese Biomedical Literature Database (CBM) and Chinese Journal Full-text Database, to include RCTs of different mesh fixation methods (or fixation vs no fixation) during open inguinal hernia repair. The risk of bias in included RCTs will be evaluated according to the Cochrane Handbook V.5.1.0. Standard pairwise meta-analysis, trial sequential analysis and Bayesian network meta-analysis will be performed to compare the efficacy of different mesh fixation methods. Ethics and dissemination Ethical approval and patient consent are not required since this study is a meta-analysis based on published studies. The results of this network meta-analysis and trial sequential analysis will be submitted to a peer-reviewed journal for publication. Protocol registration number PROSPERO CRD42015023758. PMID:26586326

  13. Management of Concomitant Cancer and Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Abdullah Jibawi

    2011-01-01

    Full Text Available Background. The coexistence of neoplasm and abdominal aortic aneurysm (AAA presents a real management challenge. This paper reviews the literature on the prevalence, diagnosis, and management dilemmas of concurrent visceral malignancy and abdominal aortic aneurysm. Method. The MEDLINE and HIGHWIRE databases (1966-present were searched. Papers detailing relevant data were assessed for quality and validity. All case series, review articles, and references of such articles were searched for additional relevant papers. Results. Current challenges in decision making, the effect of major body-cavity surgery on an untreated aneurysm, the effects of major vascular surgery on the treatment of malignancy, the use of EVAR (endovascular aortic aneurysm repair as a fairly low-risk procedure and its role in the management of malignancy, and the effect of other challenging issues such as the use of adjuvant therapy, and patients informed decision-making were reviewed and discussed. Conclusion. In synchronous malignancy and abdominal aortic aneurysm, the most life-threatening lesion should be addressed first. Endovascular aneurysm repair where possible, followed by malignancy resection, is becoming the preferred initial treatment choice in most centres.

  14. Colorectal cancer associated with abdominal aortic aneurysm: results of EVAR followed by colectomy.

    Science.gov (United States)

    Illuminati, Giulio; Ceccanei, Gianluca; Pacilè, Maria A; Pizzardi, Giulia; Palumbo, Piergaspare; Vietri, Francesco

    2013-01-01

    The association of colorectal cancer and abdominal aortic aneurysm (AAA) is infrequent but poses special problems of priority of treatment under elective circumstances. The purpose of this study was to retrospectively evaluate the outcome of 16 consecutive patients undergoing endovascular aneurysm repair (EVAR) followed by colectomy. Operative mortality was nil. Operative morbidity included two transient rise of serum creatinine level and one extraperitoneal anastomotic leakage which evolved favourably with conservative treatment. EVAR allowed a very short delay of treatment of colorectal cancer after aneurysm repair, minimizing operative complications.

  15. Cephalic vein aneurysm.

    Science.gov (United States)

    Faraj, Walid; Selmo, Francesca; Hindi, Mia; Haddad, Fadi; Khalil, Ismail

    2007-11-01

    Cephalic vein aneurysms are rare malformations that may develop in any part of the vascular system, and their history, presentation, and management vary depending on their site. The etiology of venous aneurysms remains unclear, although several theories have been elaborated. Venous aneurysms are unusual vascular malformations that occur equally between the sexes and are seen at any age; they can present as either a painful or a painless subcutaneous mass. No serious complications have been reported from upper extremity venous aneurysms. Surgical excision is the definitive management for most of these. The case reported here presented with a painless and mobile, soft, subcutaneous mass that caused only cosmetic concern.

  16. Posterior spinal artery aneurysm rupture after 'Ecstasy' abuse.

    Science.gov (United States)

    Johnson, Jeremiah; Patel, Shnehal; Saraf-Lavi, Efrat; Aziz-Sultan, Mohammad Ali; Yavagal, Dileep R

    2015-07-01

    Posterior spinal artery (PSA) aneurysms are a rare cause of subarachnoid hemorrhage (SAH). The commonly abused street drug 3,4-methylenedioxymethamphetamine (MDMA) or 'Ecstasy' has been linked to both systemic and neurological complications. A teenager presented with neck stiffness, headaches and nausea after ingesting 'Ecstasy'. A brain CT was negative for SAH but a CT angiogram suggested cerebral vasculitis. A lumbar puncture showed SAH but a cerebral angiogram was negative. After a spinal MR angiogram identified abnormalities on the dorsal surface of the cervical spinal cord, a spinal angiogram demonstrated a left PSA 2 mm fusiform aneurysm. The patient underwent surgery and the aneurysmal portion of the PSA was excised without postoperative neurological sequelae. 'Ecstasy' can lead to neurovascular inflammation, intracranial hemorrhage, SAH and potentially even de novo aneurysm formation and subsequent rupture. PSA aneurysms may be treated by endovascular proximal vessel occlusion or open surgical excision.

  17. [Use of an iliac branched endoprostheis in endovascular treatment for an abdominal aortic aneurysm combined with aneurysms of both common iliac arteries].

    Science.gov (United States)

    Imaev, T E; Kuchin, I V; Lepilin, P M; Kolegaev, A S; Medvedeva, I S; Komlev, A E; Akchurin, R S

    An abdominal aortic aneurysm appears to be combined with aneurysmatic lesions of the common iliac arteries in 30-40% of cases. Like abdominal aortic aneurysms, aneurysms of the common iliac arteries rarely manifest themselves clinically. The lethality rate in case of rupture is comparable to that for rupture of an abdominal aortic aneurysm. During endoprosthetic repair of abdominal aortic aneurysms combined with aneurysms of the common iliac arteries, in order to prevent endoleaks and to improve the distal zone of fixation of endografts surgeons often resort to embolization of internal iliac arteries, which may lead to ischaemic postoperative complications. One of the methods of preserving pelvic blood flow is the use of an iliac branched endograft. A series of studies evaluating long-term outcomes demonstrated that this method proved to be both safe and effective, and with the suitable anatomy is a method of choice in high surgical risk patients. The present article deals with a clinical case report concerning bilateral endoprosthetic repair of the common iliac arteries, combined with endoprosthetic repair of an abdominal aortic aneurysm, with the description of technical peculiarities of implanting an iliac branched graft.

  18. Intraorbital ophthalmic artery aneurysm associated with basilar tip saccular aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Dehdashti, A.R.; Tribolet, N. de [Department of Neurosurgery, HUG, Geneva (Switzerland); Safran, A.B. [Department of Ophthalmology, HUG, Geneva (Switzerland); Martin, J.B.; Ruefenacht, D.A. [Division of Neuroradiology, HUG, Geneva (Switzerland)

    2002-07-01

    We present a rare case of intraorbital ophthalmic artery aneurysm found incidentally, together with a ruptured aneurysm of the tip of the basilar artery. The intraorbital aneurysm was asymptomatic, and no treatment was offered. Angiographic control was recommended to detect any progression. Treatment may be indicated for documented enlargement or significant mass effect of the aneurysm. (orig.)

  19. Ruptured abdominal aortic aneurysm and aortoiliac vein fistula.

    Science.gov (United States)

    Gyoten, Takayuki; Doi, Toshio; Yamashita, Akio; Fukahara, Kazuaki; Kotoh, Keiju; Yoshimura, Naoki

    2015-05-01

    A 67-year-old man was admitted with severe abdominal pain and back pain. Computed tomography showed an infrarenal abdominal aortic aneurysm (8.4 × 8.3 cm) and a large retroperitoneal hematoma. Immediately afterwards, the patient suffered circulatory collapse and was rushed to the operating theater. A fistula communicating with the left iliac vein was found. It was repaired with a Dacron patch while balloon-tipped catheters controlled the bleeding. The abdominal aortic aneurysm was replaced with a bifurcated graft. The postoperative course was uneventful. There have been few reports of successful repair of a ruptured abdominal aortic aneurysm associated with aortoiliac arteriovenous fistula.

  20. [From the Cochrane Library: ultrasonographic screening for abdominal aortic aneurysm in men aged 65 years and older: low risk of fatal aneurysm rupture].

    Science.gov (United States)

    Hamerlynck, J V T H; Legemate, D A; Hooft, L

    2008-03-29

    Abdominal aortic aneurysm (AAA) is present in 5-10% of men aged 65-79 years and is often asymptomatic. The major complication is rupture, which requires emergency surgery. The mortality rate after rupture is high: about 80% of those who reach the hospital and 50% of those undergoing emergency surgery will die. Elective surgical repair of AAA aims to prevent death from rupture; the 30-day surgical mortality rate for open surgery is approximately 5%. Currently elective surgical repair is recommended for aneurysms larger than 5-5 cm to prevent rupture. There is interest in population screening to detect, monitor and repair AAA before rupture. A Cochrane systematic review of 4 randomised studies involving 127,891 men and 9,342 women revealed a significant reduction in mortality from AAA in men aged 65-79 years who underwent ultrasonographic screening (odds ratio (OR): 0.60; 95% CI: 0.47-0.78). There was insufficient evidence to demonstrate a benefit in women. Men who had been screened underwent more surgery for AAA (OR: 2.03; 95% CI: 1.59-2.59). These findings should be considered carefully when determining whether a coordinated population-based screening programme should be introduced. A gap in the current research is the balance of benefits and risks in women. Furthermore, detailed studies are needed on how to best provide information on the potential benefits and risks to individuals who are offered screening, and on the psychological effects of screening on patients and their partners.

  1. Aortic coarctation, aneurysm, and ventricular dysfunction in an asymptomatic infant.

    Science.gov (United States)

    García, Ana I; Aguilar, Juan M; García, Enrique

    2016-06-01

    Aortic arch coarctation with post-coarctation aneurysm is rare in infants. We present the case of an asymptomatic 3-month-old infant with severe left ventricular dysfunction in this setting. The patient underwent surgical repair, and the left ventricular ejection fraction improved to recovery the 4th post-operative month.

  2. Analysis of repair scheme for opening in submarine%某型潜艇开孔修补方案的分析

    Institute of Scientific and Technical Information of China (English)

    赵健; 邵优华; 周惠元

    2013-01-01

    Aiming at repair scheme of error opening in the submarine pressure hull ,this paper uses finite element analysis method to calculate its deformation and stress. The repair scheme for this submarine has been proved through analysis of calculation results and evaluation of the two construction schemes ,which can accumulate experience for the similar ship maintenance in the further.%针对潜艇耐压壳体误开孔的修补方案,采用有限元分析法,对潜艇耐压壳体的变形和应力进行计算。通过对计算结果的分析以及对两个施工方案的评估,肯定了该型潜艇的修补方案,为后期开展类似的舰艇维修积累了经验。

  3. Surgical management of large and giant intracavernous and paraclinoid aneurysms

    Institute of Scientific and Technical Information of China (English)

    Xu Bai-nan; SUN Zheng-hui; JIANG Jin-li; WU Chen; ZHOU Ding-biao; YU Xin-guang; LI Bao-min

    2008-01-01

    Background Due to their location,large and giant intracavernous and paraclinoid aneurysms remain a challenge for vascular neurosurgeons.We identified characteristics.surgical indications and treatment strategies of large and giant intracavernous and paraclinoid aneurysms in 36 patients.Methods The pterional approach was routinely used.The cervical internal carotid artery was exposed for proximal control of parent vessel and retrograde suction decompression.Paraclinoid aneurysms were directly clipped,intracavernous pseudoaneurysm was repaired and the intracavernous aneurysms were trapped with extracranial-intracranial bypass of saphenous vein graft.Intraoperative electroencephaIogram (EEG) and somatosensory evoked potential (SSEP) monitoring were used to detect cerebral ischemia during the temporary occlusion of parent arteries.Microvascular Doppler ultrasonography was used to assess blood flow of the parent and branch vessels.Endoscopy was helpful particularly in dealing with internal carotid artery posterior wall aneurysms.Postoperative digital subtraction angiography (DSA) was performed in 33 of the 36 patients.Results Thirty-two paraclinoid aneurysms were directly clipped,1 intracavernous pseudoaneurysm was repaired and the other 3 intracavernous aneurysms were trapped with revascula rization.Except for two patients who died in the early postoperative stage,34 patients' follow-up was 6-65 months (mean 10 months)and a Glasgow Outcome Scale score of 4 to 5 at discharge.At the 6-month follow-up examination,Rankin Outcome Scale scores were 0 to 2 in 32 patients.EEG and SSEP monitoring changed in six patients.Twelve clips were readjusted when insufficient blood flow in parent and branch vessels was detected.Three posterior wall aneurysms were clipped.Conclusions Intracavernous aneurysms not amenable to endovascular treatment should be treated surgically and surgical treatment is the first option for paraclinoid aneurysms.The temporary parent vessel occlusion

  4. Multilocular True Ulnar Artery Aneurysm in a Pediatric Patient.

    Science.gov (United States)

    Stalder, Mark W; Sanders, Christopher; Lago, Mary; Hilaire, Hugo St

    2016-01-01

    Ulnar artery aneurysms are an exceedingly rare entity in the pediatric population and have no consistent etiologic mechanism. We present the case of a 15-year-old male with a multilocular ulnar artery aneurysm in the setting of no antecedent history of trauma, no identifiable connective tissue disorders, and no other apparent etiological factors. Furthermore, the patient's arterial palmar arch system was absent. The aneurysm was resected, and arterial reconstruction was successfully performed via open surgical approach with cephalic vein interposition graft. We believe this treatment modality should be considered as the primary approach in all of these pediatric cases in consideration of the possible pitfalls of less comprehensive measures.

  5. Repair of open compound lower extremity wounds%下肢开放复杂伤口与创面的修复

    Institute of Scientific and Technical Information of China (English)

    朱敬民; 陈传功; 种亚林; 郝天智; 鲁刚; 周智; 随志甫; 刘静杰; 屠晓军; 罗金超; 范宝玉

    2008-01-01

    Objective To explore the repair of the open compound wounds in lower extremities caused by multiple factors. Methotis Transplantation of cutaneous.musculo-cutaneous or greater omentum flaps were applied to 155 patients of open compound lower extremity wounds. Results The wound healing rate following first operation was 50% and that following two operations was 14.8%.While the wounds were healed in 7.7% of patients after three operations. Conclusion Transplantations of cutaneous,musculo-cutaneous or greater omentum flaps ale effective to repair and reconstruct the open compound lower extremity wounds.%目的 探讨多种原因造成的下肢开放复杂伤口与创面的修复.方法 应用皮瓣、肌皮瓣、大网膜移植等方法,对155例下肢复杂伤口与创面进行修复.结果 一次手术愈合率为50%;两次手术愈合率为14.8%;三次手术愈合率为7.7%.结论 皮瓣、肌皮瓣以及大网膜移植,可以有效修复多种原因造成的下肢复杂伤口与创面.

  6. Cleft lip repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100010.htm Cleft lip repair - series—Normal anatomy To use the sharing ... abnormal opening in the middle of the upper lip. A cleft palate is an opening in the roof of ...

  7. [Risk factors for long-term result of endovascular treatment for auto-immune disease related abdominal aorta pseudo-aneurysm].

    Science.gov (United States)

    Ye, W; Di, X; Liu, Q; Li, Y J; Zheng, Y H; Zeng, R; Song, X J; Liu, Z L; Liu, C W

    2016-12-06

    Objective: To summarize results of endovascular treatment for auto-immune disease related abdominal aorta pseudo-aneurysm(AIPA), and to analysis clinical predictors of long term major adverse clinical events(MACE). Methods: Retrospectively collected endovascular treatment for AIPA cases in Peking Union Medical College Hospital within 2000 to 2015. Twenty-nine cases with AIPA treated by endovascular therapy were enrolled in this study. Twenty five cases were male, range from 23 to 67 years old, mean age was (39.3±11.4) years old.Demographic characters, locations of aneurysms, type to auto-immune disease, immuno medical therapy, operation strategy and long term follow-up data were reported. Statistical analysis was made to verify clinical predictors of long-term MACE. Results: Among the 29 cases, 22 cases with bechet's disease, 4 cases with Takayasu's arteritis, 2 cases with systemic lupus erythematosus, 1 cases with polyarteritis nodosa. Eight cases had ruptured or pending ruptured pesudo-aneurysms, the rest 21 cases had dull pain or no overt symptome. Twenty-four cases had infra-renal artery aneurysms, two were para-and supra-renal artery, two were supra-celiac artery, and the rest one had multiple aneurysms involved thoracic and abdominal aorta.All the cases received regular immune medical therapy except the three emergency cases. All the operations were under general anaesthesia. Nineteen cases underwent classical Endovascular aortic aneurysm repair (EVAR), 5 cases underwent fenestration EVAR, the rest 5 cases underwent hybrid procedure. All the 29 operations were successful, without conversion to open surgery. Major peri-operation complication included 3 incision infection, 3 pulmonary infection. No death occurred. All the cases received regular follow-up from 1 to 120 months. There were five recurrence of pseudo-aneurysm, 1 case suffered from iliac limb occlusion. 5 cases received re-intervention procedure. No occlusion of revascularizal visceral artery was

  8. Comparision study of therapeutic effection between laparosccopical incision henia repair and open incision henia repair%腹腔镜切口疝修补术与开放式切口疝修补术的比较研究

    Institute of Scientific and Technical Information of China (English)

    王东; 刘昶; 许军

    2011-01-01

    目的:比较腹腔镜切口疝修补术(LVHR)与开放切口疝修补术(OVHR)的临床疗效.方法:总结我院2005年1月-2011年1月治疗的腹壁切口疝(VIH)72例患者的临床资料,其中OVHR组32例,LVHR组40例.结果:OVHR组手术时间60~ 145min,平均手术时间(90±35)min;术中出血25~200 m L,平均(95±15)mL;住院时间4~35 d,平均(7.5±5.8)d,术区感染3例.LVHR组手术时间35~135 min,平均手术时间(82±32)min;术中出血15~160 mL,平均(85±12)mL,术区感染0例;住院时间3~8d,平均(5.5±1.6)d.患者随访3个月~5年,OVHR组复发2例(6.3%),LVHR组复发3例(7.5%).结论:WHR同OVHR同样安全有效,但LVHR可明显降低切口感染并发症、减少术后疼痛、缩短术后住院时间.%Objeetive: To compare the safety and benefits of laparoscopic(LVHR) and open incision hernia repai (OVHR). Methods: The clinical data of 72 patients with incision hernia receiving incision hernia repair in the Fourth Hospital of Harbin Medical University were analyzed among 40 cases which received laparoscopic incision hernia repair and 32 cases received open incision hernia repair. Results: The operative time was 60 ~ 145 min (mean 90 ± 35 min)and 35 -135 min(mean 82 ± 32 min)in OVHR group and LVHR group respectively- The blood losses were 25 ~ 200 mL(mean 95 ± 15 mL) and 5 ~ 160 mL(mean 85 ± 12 mL) in OVHR group and LVHR group respectively. Postoperative stay was 4 ~ 35 d (mean 7.5 ± 5.8 d) and 3 ~ 8 d (mean 5.5 ± 1.6 d) (P<0.05)in OVHR group and LVHR group respectively. Incision infection appeared 3 cases in OVHR group and no in LVHR group (P<0.05). Recurrence occurred in 2 cases and 3cases in OVHR group and LVHR group respectively during follow up period of 3 months to 5 years. Conclusions The laparoscopic inci-sional hernia repair is a safe and effective method as open incision hernia repair, and laparoscopic incisional hernia repair has less incision infection,can lessen pains and shorten postoperative

  9. Pediatric cerebral aneurysms.

    Science.gov (United States)

    Gemmete, Joseph J; Toma, Ahmed K; Davagnanam, Indran; Robertson, Fergus; Brew, Stefan

    2013-11-01

    Childhood intracranial aneurysms differ from those in the adult population in incidence and gender prevalence, cause, location, and clinical presentation. Endovascular treatment of pediatric aneurysms is the suggested approach because it offers both reconstructive and deconstructive techniques and a better clinical outcome compared with surgery; however, the long-term durability of endovascular treatment is still questionable, therefore long-term clinical and imaging follow-up is necessary. The clinical presentation, diagnosis, and treatment of intracranial aneurysms in children are discussed, and data from endovascular treatments are presented.

  10. 血管内支架锚定器装置在胸腹主动脉瘤腔内修复术中的应用现况与系统评价%EndoAnchor systems for vascular endografts in endovascular aneurysm repair:application status and systematic review

    Institute of Scientific and Technical Information of China (English)

    魏猛; 朱化刚; Michael Feldmann

    2016-01-01

    目的:研究血管内支架锚定器(ANCHOR)装置在主动脉瘤腔内修复术(T/EVAR)的应用现状及治疗效果。方法结合应用实践并以 ANCHOR、endoAnchor、endostapling、EVAR、endograft、endoleaks和vascular endosaple为关键词检索纳入截至2015年7月的18篇研究文献进行系统综述和评价。结果文献资料系统分析和临床应用实践表明,在适当选择的患者中,T/EVAR血管内支架锚定器的应用能减少支架移位和Ⅰ型内漏的发生,降低支架相关的并发症发生率和死亡率,提高动脉瘤的修复成功率。结论 T/EVAR术应用ANCHOR装置锚定支架是安全可行的,一定程度上提高了支架的稳定性和有效性,并使得许多高危型主动脉瘤采用T/EVAR术修复成为可能。%Objective To study the current state and treatment outcome of vascular endoAnchor systems (ANCHOR) in thoracic endovascular aneurysm repair (T/EVER) with a systematic review. Methods Eighteen studies included were systematically reviewed by key words with ANCHOR , endoAnchor, endostapling, EVAR, endograft, endoleaks and vascular endostaple up to July 2015 and evaluated based on clinical practice. Results The systematic review of literatures and clinical practice showed that in appropriately selected patients , the application of ANCHOR considerably reduced the rates of stent migration and type Ⅰ endoleak, decreased the stent-related complication rates and mortality , and increased the treatment success rate of aneurysm repair. Conclusion The application of ANCHOR in T/EVAR is safe and feasible, and enhances the stability and efficacy of stents, making T/EVAR possible for many high risk aortic aneurysms.

  11. Tratamento endovascular do aneurisma da aorta abdominal infrarrenal em pacientes com anatomia favorável para o procedimento: experiência inicial em um serviço universitário Endovascular treatment of infrarenal abdominal aortic aneurysm in patients with favorable anatomy for the repair: initial experience in a university hospital

    Directory of Open Access Journals (Sweden)

    José Manoel da Silva Silvestre

    2011-03-01

    Full Text Available CONTEXTO: Desde sua introdução, em 1991, o reparo endovascular do aneurisma da aorta abdominal infrarrenal tem se tornado uma alternativa atraente para o tratamento dessa doença. Avaliar nossos resultados iniciais quanto à segurança e eficácia dessa técnica nos levou à realização deste estudo. OBJETIVOS: Analisar a mortalidade perioperatória, a sobrevida tardia, as reoperações, as taxas de perviedade e o comportamento do saco aneurismático em pacientes com anatomia favorável para a realização do procedimento. MÉTODOS: Trata-se de um estudo longitudinal, observacional e retrospectivo realizado entre outubro de 2004 e janeiro de 2009 com 41 pacientes que foram submetidos à correção endovascular do aneurisma de aorta abdominal infrarrenal por apresentarem anatomia favorável para o procedimento. Foram analisados os achados dos exames diagnósticos, o tratamento e o seguimento em todos os pacientes. RESULTADOS: Foram implantadas, com sucesso, 31 (75,6% próteses bifurcadas e 10 (24,5% monoilíacas, de 5 diferentes marcas. O diâmetro médio dos aneurismas fusiformes era de 62 mm. A mortalidade perioperatória foi de 4,8% e a sobrevida tardia, 90,2%. Durante o acompanhamento médio de 30 meses, 2 (4,8% pacientes necessitaram de reintervenção, um por migração da endoprótese e outro por vazamento tipo II. Dois (4,8% pacientes apresentaram oclusão de ramo da prótese. Oito (19,5% vazamentos foram diagnosticados e não houve nenhuma rotura dos aneurismas. CONCLUSÃO: Apesar do pequeno número de pacientes, os resultados observados parecem justificar a realização do procedimento endovascular nos pacientes com anatomia favorável.BACKGROUND: Since its introduction in 1991, endovascular repair of infrarenal aortic aneurysms has become an attractive option to treat this disease. The evaluation of our initial results about safety and efficacy of this technique has led us to carry out this study. OBJECTIVES: To analyze

  12. Most Coarctations, Recoarctations, and Coarctation-Related Aneurysms Should Be Treated Endovascularly Based on a Presentation at the 2013 VEITH Symposium, November 19–23, 2013 (New York, NY, USA)

    Science.gov (United States)

    Galiñanes, Edgar Luis; Krajcer, Zvonimir

    2015-01-01

    For patients with coarctation of the aorta (CoA), surgical intervention results in an overall survival rate nearly twice that of medical management. Therefore, surgical correction of CoA has traditionally been warranted in the majority of patients, even though open repair entails its own complications. With the advent of endovascular technology, many interventionalists hoped that this approach would decrease the complications associated with open surgical repair of CoA. Nevertheless, there is still an ongoing debate about the merits of traditional open surgery versus endovascular therapy. In this review, we discuss the role of these two approaches for the management of CoA, recoarctation, and coarctation-related aneurysms. PMID:27069944

  13. 腹腔镜腹股沟疝修补与开放性腹股沟疝修补的疗效对比研究%Comparative study on the laparoscopic inguinal hernia repair and open inguinal hernia repair

    Institute of Scientific and Technical Information of China (English)

    施景龙; 陈海生; 褚中华

    2014-01-01

    目的:比较腹腔镜腹股沟疝修补与开放性腹股沟疝修补的优缺点。方法对2012年5月~2013年5月中山市中医院240例成人腹股沟疝修补术进行回顾性分析,其中开放性疝修补术(开腹疝修补组)148例,腹腔镜疝修补术(腔镜疝修补组)92例。收集两组患者的手术时间、住院时间、住院费用、术后复发、术后慢性疼痛、术后阴囊积液及术后感染的临床资料并进行比较。结果开腹疝修补组患者在平均手术时间、平均住院费用少于腔镜疝修补(P 均<0.01);开腹疝修补组术后复发(3例)、术后慢性疼痛(11例)、术后阴囊积液(2例)及术后感染(1例)等总并发症高于腔镜疝修补组(P<0.05);两组的平均住院时间差异无统计学意义。结论腔镜组腹股沟疝修补术具有较少的术后并发症,但在住院时间、住院费用方面没有优势。%Objective To compare the efficacy between laparoscopic inguinal hernia repair and open inguinal hernia repair. Methods From May 2012 to May 2013, 240 cases of adult inguinal hernia repair were retrospectively analyzed. Of 240 cases ,148 cases underwent open herniorrhaphy (open group), 92 underwent laparoscopic herniorrhaphy (laparoscope group). The clinical parameters of two groups were recorded and analyzed,including operation time,.length of hospital stay, hospital expenses,. postoperative recurrence,.postoperative chronic pain,.postoperative scrotal hydrops and postoperative infection. Results The average operation time and hospitalization expenses for open group was 62.9± 9.8 min and 8420±2481 yuan,.lower than that laparoscopic group (76.2±9.4 min and 12468±33858 yuan,P<0.01). However, postoperative complications in open group were including recurrence (3 cases), chronic postoperative pain(11 cases), postoperative scrotal hydrops (2 cases), postoperative infection (1 case) were higher than that in laparoscopic group (P

  14. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair

    OpenAIRE

    Zhu, Kai; Lai, Hao; Guo, Changfa; Li, Jun; Wang, Chunsheng

    2014-01-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report...

  15. Cerebral Aneurysms Fact Sheet

    Science.gov (United States)

    ... the flow of blood to the aneurysm. Under anesthesia, a section of the skull is removed and ... Page NINDS Inclusion Body Myositis Information Page Traumatic Brain Injury Information Page NINDS Incontinentia Pigmenti Information Page Trigeminal ...

  16. Intracranial Arterial Aneurysms

    OpenAIRE

    J Gordon Millichap

    1988-01-01

    Neurosurgeons from the Universita degli Studi di Roma “La Saspeinza,” Rome, Italy, report a 4-year-old girl with a cerebral saccular aneurysm and analyze 71 cases under 5 years of age in the literature.

  17. Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Springer, Fabian; Pfeffer, Joachim-Georg; Schmitz-Rode, Thomas [RWTH Aachen University, Helmholtz-Institute for Biomedical Engineering, Applied Medical Engineering, Aachen (Germany); Schlierf, Roland; Schnakenberg, Uwe [RWTH Aachen University, Institute of Materials in Electrical Engineering I, Aachen (Germany); Mahnken, Andreas H. [RWTH Aachen University, Helmholtz-Institute for Biomedical Engineering, Applied Medical Engineering, Aachen (Germany); RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany)

    2007-10-15

    A feasibility study on a completely digital telemetric pressure sensor (TPS) to detect endoleaks was performed in an in vitro model of an abdominal aortic aneurysm (AAA). An endovascular-stented AAA silicone model with different types (I-III) and sizes (3-11 French) of endoleaks was created and pulsatile pressure was applied with physiological flow and pressure rates [mean intraaortic pressure (IAP): 95-130 mmHg] and different degrees of thrombosis of the aneurysm sac. Aneurysm sac pressure (ASP) was measured with the TPS and with wired pressure sensors (WPS) as a reference. Statistical analysis included paired t-test, Pearson's correlation analysis and Bland-Altman plots. After opening an endoleak, the mean ASP increased significantly (P < 0.0001) from 15 to almost 95% of the mean IAP depending on endoleak type and size. ASP could be measured accurately with the TPS and the WPS. The telemetric and wired ASP increase showed a high Pearson's correlation coefficient (r) for a non-thrombosed (r = 0.97) and a thrombosed (r = 0.96) aneurysm sac. In an in vitro silicone model, the newly designed telemetric pressure sensor was able to detect the occurrence of an endoleak in a non-invasive way and might be a valuable device for follow-up of endovascular AAA repair. (orig.)

  18. Symptomatic regrowth of a small intracranial aneurysm that had ruptured and completely thrombosed: a case report

    Directory of Open Access Journals (Sweden)

    Hidetoshi Ooigawa

    2015-06-01

    Full Text Available We report a case of small internal carotid–posterior communication artery (IC–PC aneurysm that was completely thrombosed after initial bleeding, but subsequently became symptomatic, causing a mass effect. A 54-year-old woman initially presented with grade-five subarachnoid hemorrhage from a small right IC–PC aneurysm. The aneurysm was treated conservatively and completely thrombosed within 35 days. The patient slowly recovered and remained well until 4 years later, when she developed right oculomotor nerve palsy. Imaging revealed relapse of the aneurysm, and repair led to symptom resolution. This case offers a reminder that totally thrombosed aneurysms carry a risk of regrowth if left untreated.

  19. Introduction of endovascular embolization for intracranial aneurysms in a low-volume institution

    DEFF Research Database (Denmark)

    Lindekleiv, H M; Jacobsen, E A; Kloster, R

    2009-01-01

    BACKGROUND: Studies indicate a relationship between hospital caseload and health outcomes after both surgical and endovascular repair of intracranial aneurysms. PURPOSE: To evaluate outcomes after introduction of endovascular embolization for intracranial aneurysms in a low-volume regional...... university hospital. MATERIAL AND METHODS: Retrospective study of 243 consecutive patients treated for 284 intracranial aneurysms with endovascular embolization or surgical clipping from 2000 to 2006 at the University Hospital of North Norway. Postoperative complications were registered. The Glasgow Outcome...... Scale (GOS) was used for assessment of outcome. RESULTS: The mean annual number of procedures was 39 (microsurgery 23, embolization 16). Seventy-four percent of patients with ruptured aneurysms and all patients with unruptured aneurysms had a favorable outcome (GOS 4 or 5) at 1 year follow-up. Patients...

  20. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    The endovascular treatment of intracranial aneurysms 3 mm or less is considered controversial. The purpose of this study is to report angiographic and clinical results following coiling of such aneurysms and compare them to those of larger aneurysms (> 3 mm).Between November 1999 and November 2009...... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... and subsequently comparing it to the results of larger aneurysms.Coiling initially failed in eight aneurysms. In the remaining 103 aneurysms endovascular treatment was accomplished and immediate angiographic results showed complete aneurysm occlusion in 43 aneurysms, nearly complete aneurysm occlusion in 54...

  1. Screening for Abdominal Aortic Aneurysm

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Abdominal Aortic Aneurysm The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation statement on Screening for Abdominal Aortic Aneurysm. This final ...

  2. Rapid growth of an infectious intracranial aneurysm with catastrophic intracranial hemorrhage.

    Science.gov (United States)

    Koffie, Robert M; Stapleton, Christopher J; Torok, Collin M; Yoo, Albert J; Leslie-Mazwi, Thabele M; Codd, Patrick J

    2015-03-01

    Infectious intracranial aneurysms are rare vascular lesions that classically occur in patients with infective endocarditis. We present a 49-year-old man with altered mental status and headache with rapid growth and rupture of an infectious intracranial aneurysm with catastrophic intracranial hemorrhage, and review issues related to open neurosurgical and endovascular interventions.

  3. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair.

    Science.gov (United States)

    Zhu, Kai; Lai, Hao; Guo, Changfa; Li, Jun; Wang, Chunsheng

    2014-12-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report suggests that the palliative strategy may be an option for RAD in some specific situation.

  4. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair

    Science.gov (United States)

    Zhu, Kai; Guo, Changfa; Li, Jun

    2014-01-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report suggests that the palliative strategy may be an option for RAD in some specific situation. PMID:25590002

  5. Endoleakage after endovascular treatment of abdominal aortic aneurysms: diagnosis, significance and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Golzarian, Jafar [University of Iowa, University of Iowa Heath Care, IA (United States); Valenti, David [McGill University, Royal Victoria Hospital, McGill University Health Centre, Montreal (Canada)

    2006-12-15

    Endoleak, also called leakage, leak and Perigraft leak, is a major complication and its persistence represents a failure of endovascular aortic aneurysm repair. Its detection and treatment is therefore of primary importance, since endoleak can be associated with pressurization (increase in pressure) of the sac, resulting in expansion and rupture of the aneurysm. The aim of this paper is to discuss the definition, significance, diagnosis and different options to treat endoleak. (orig.)

  6. Chronic complete thrombosis of abdominal aortic aneurysm: an unusual presentation of an unusual complication.

    Science.gov (United States)

    Pejkic, Sinisa; Opacic, Dragan; Mutavdzic, Perica; Radmili, Oliver; Krstic, Nevena; Davidovic, Lazar

    2015-02-01

    Although mural thrombosis frequently accompanies aneurysmal disease, complete thrombosis is distinctly unusual complication of abdominal aortic aneurysm (AAA). A case study of a patient with chronic, asymptomatic complete thrombosis of a large juxtarenal AAA is presented along with a literature review and discussion of the potential secondary complications, mandating aggressive management of this condition. A 67-year-old man with multiple atherogenic risk factors and unattended complaints consistent with a recent episode of a transient right hemispheric ischemic attack was referred to our clinic with a diagnosis of a thrombosed AAA established by computed tomography. Duplex ultrasonography and aortography confirmed the referral diagnosis and also revealed near occlusion of the left internal carotid artery. The patient underwent a two-stage surgery, with preliminary left-sided carotid endarterectomy followed three days later by an aneurysmectomy and aortobifemoral reconstruction. He had an uncomplicated recovery and was discharged home on postoperative day 7, remaining asymptomatic at the 42-month follow-up. Complete thrombosis is an uncommon presentation of AAA and may be clinically silent. It is frequently associated with other manifestations of generalized atherosclerosis. Radical open repair yields durable result and is the preferred treatment modality.

  7. Huge aneurysm and coronary-cameral fistula from right coronary branch: First case.

    Science.gov (United States)

    Ahmad, Tanveer; Pasarad, Ashwini Kumar; Kishore, Kolkebaile Sadanand; Maheshwarappa, Nandakumar Neralakere

    2016-02-01

    Coronary-cameral fistulas are rare cardiovascular anomalies. A giant coronary artery aneurysm associated with a coronary-cameral fistula is a very rare condition, with an estimated prevalence of 0.02%. We report the case of middle-aged woman who presented with a huge extracardiac aneurysmal mass and a coronary-cameral fistula from a right coronary artery branch. It was successfully repaired by ligation and excision plus marsupialization of the aneurysm. We believe this is the first such a case reported in literature.

  8. Giant right coronary artery aneurysm with unusual physiology: Role of intraoperative transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    David M Orozco

    2012-01-01

    Full Text Available A 65-year-old woman presented with a history of dyspnea and atypical chest pain. She was diagnosed with a non-ST-segment elevation myocardial infarction due to a giant right coronary artery aneurysm. After a failed percutaneous embolization, she was scheduled for right coronary artery aneurysm resection, posterior descending artery revascularization and mitral valve repair. During the induction of anesthesia and institution of mechanical ventilation, the patient suffered cardiovascular collapse. The transesophageal echocardiographic examination revealed tamponade physiology owing to compression of the cardiac chambers by the unruptured aneurysm, which resolved with the sternotomy. The surgery was carried out uneventfully.

  9. Risk of Familial Intracranial Aneurysm

    OpenAIRE

    J Gordon Millichap; Millichap, John J.

    2014-01-01

    Investigators at University Medical Center Utrecht, Netherlands, studied the yield of long-term (up to 20 years) screening for intracranial aneurysms in individuals with a positive family history (2 or more first-degree relatives) of aneurysmal subarachnoid hemorrhage (aSAH) or unruptured intracranial aneurysm (1993-2013).

  10. Mouse models of intracranial aneurysm.

    Science.gov (United States)

    Wang, Yutang; Emeto, Theophilus I; Lee, James; Marshman, Laurence; Moran, Corey; Seto, Sai-wang; Golledge, Jonathan

    2015-05-01

    Subarachnoid hemorrhage secondary to rupture of an intracranial aneurysm is a highly lethal medical condition. Current management strategies for unruptured intracranial aneurysms involve radiological surveillance and neurosurgical or endovascular interventions. There is no pharmacological treatment available to decrease the risk of aneurysm rupture and subsequent subarachnoid hemorrhage. There is growing interest in the pathogenesis of intracranial aneurysm focused on the development of drug therapies to decrease the incidence of aneurysm rupture. The study of rodent models of intracranial aneurysms has the potential to improve our understanding of intracranial aneurysm development and progression. This review summarizes current mouse models of intact and ruptured intracranial aneurysms and discusses the relevance of these models to human intracranial aneurysms. The article also reviews the importance of these models in investigating the molecular mechanisms involved in the disease. Finally, potential pharmaceutical targets for intracranial aneurysm suggested by previous studies are discussed. Examples of potential drug targets include matrix metalloproteinases, stromal cell-derived factor-1, tumor necrosis factor-α, the renin-angiotensin system and the β-estrogen receptor. An agreed clear, precise and reproducible definition of what constitutes an aneurysm in the models would assist in their use to better understand the pathology of intracranial aneurysm and applying findings to patients.

  11. Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm with Unibody Bifurcated Stent-Grafts%分叉型一体式覆膜支架腔内治疗肾下型腹主动脉瘤的疗效

    Institute of Scientific and Technical Information of China (English)

    史伟浩; 余波; 王巍

    2012-01-01

    目的:探讨应用分叉型一体式覆膜支架腔内治疗腹主动脉瘤和髂动脉瘤的疗效.方法:回顾分析采用分叉型一体式覆膜支架治疗的20例肾下型腹主动脉瘤和髂动脉瘤患者的临床资料.结果:20例患者植入分叉型一体式覆膜支架的手术成功率达100%,无围手术期死亡患者,且所有患者均未出现各类缺血性并发症.8例患者术后存在少量内漏(6例Ⅰ型内漏,2例Ⅲ型内漏),1周后内漏消失;1例患者术后发生急性肝肾功能不全,经内科治疗1周后恢复;2例患者术后出现腹股沟切口淋巴瘘,经换药愈合.平均随访15个月,所有患者未出现新的内漏和支架移位.1例患者术后1年在左侧分支支架内形成血栓,左侧髂动脉局部无血流,经导管接触溶栓治疗1d后实现血管再通.结论:应用分叉型一体式覆膜支架腔内治疗腹主动脉瘤安全有效.%Objective: To summary the clinical experience in applying unibody bifurcated stent-grafts for endovascular treatment of abdominal aortic aneurysm and iliac aneurysm. Methods: From February 2009 to March 2012, unibody bifurcated stent-grafts had been applied in the treatment of 20 patients suffering from infrarenal abdominal aortic aneurysm and iliac aneurysm. Their clinical data were analyzed. Results: A total of 100% success rate of stent implantation has been achieved without periop-erative deaths and any ischemic complications; postoperative endoleak occured in 8 cases(6 cases of type I endoleak, 2 cases of type Ⅲ endoleak) , and endoleak disappeared in all of them within one week; acute liver and kidney dysfunction occurred in one case and it was relieved after medical treatment for one week; groin incision lymphatic fistula occurred in two cases and was healed by dressing change. Patients have been followed up for an average period of 15 months. No endoleak and stent migration occurred. Conclusions: Applying unibody bifurcated stent-graft for endovascular

  12. Incidence of systemic inflammatory response syndrome after endovascular aortic repair

    DEFF Research Database (Denmark)

    De La Motte, L; Vogt, K; Jensen, Leif Panduro;

    2011-01-01

    AIM: The aim of this study was to estimate the incidence of the post-implantation syndrome/systemic inflammatory response syndrome (SIRS) after endovascular aortic repair. METHODS: All patients, undergoing elective primary endovascular repair of an asymptomatic infrarenal abdominal aortic aneurysm...

  13. Direct aneurysm sac catheterization and embolization of an enlarging internal iliac aneurysm using cone-beam CT

    Science.gov (United States)

    Merchant, Monish; Shah, Rohan; Resnick, Scott

    2015-01-01

    Since cone-beam computed tomography (CT) has been adapted for use with a C-arm system it has brought volumetric CT capabilities in the interventional suite. Although cone-beam CT image resolution is far inferior to that generated by traditional CT scanners, the system offers the ability to place an access needle into position under tomographic guidance and use the access to immediately begin a fluoroscopic procedure without moving the patient. We describe a case of a “jailed” enlarging internal iliac artery aneurysm secondary to abdominal aortic aneurysm repair, in which direct percutaneous puncture of the internal iliac artery aneurysm sac was performed under cone-beam CT guidance. PMID:25858522

  14. Endovascular abdominal aortic aneurysm repair: challenges and long-term outcomes%腹主动脉瘤腔内修复面临的挑战和远期疗效研究

    Institute of Scientific and Technical Information of China (English)

    蒋米尔; 刘光

    2011-01-01

    @@ 腹主动脉瘤(abdominal aortic aneurysm,AAA)治疗的目的在于重建主动脉管腔和血流,防止瘤样病变继续发展和破裂发生,改善与疾病自然病程有关的预后.然而传统的开腹手术存在着创伤大、恢复时间长、并发症发生率和死亡率高等诸多不利因素.

  15. [Inflammatory abdominal aortic aneurysm].

    Science.gov (United States)

    Ziaja, K; Sedlak, L; Urbanek, T; Kostyra, J; Ludyga, T

    2000-01-01

    The reported incidence of inflammatory abdominal aortic aneurysm (IAAA) is from 2% to 14% of patients with abdominal aortic aneurysm and the etiology of this disease is still discussed--according to the literature several pathogenic theories have been proposed. From 1992 to 1997 32 patients with IAAA were operated on. The patients were mostly symptomatic--abdominal pain was present in 68.75% cases, back pain in 31.25%, fever in 12.5% and weight loss in 6.25% of the operated patients. In all the patients ultrasound examination was performed, in 4 patients CT and in 3 cases urography. All the patients were operated on and characteristic signs of inflammatory abdominal aortic aneurysm like: thickened aortic wall, perianeurysmal infiltration or retroperitoneal fibrosis with involvement of retroperitoneal structures were found. In all cases surgery was performed using transperitoneal approach; in three cases intraoperatively contiguous abdominal organs were injured, which was connected with their involvement into periaortic inflammation. In 4 cases clamping of the aorta was done at the level of the diaphragmatic hiatus. 3 patients (9.37%) died (one patient with ruptured abdominal aortic aneurysm). Authors present diagnostic procedures and the differences in the surgical tactic, emphasizing the necessity of the surgical therapy in patients with inflammatory abdominal aortic aneurysm.

  16. Detection of occult endoleaks after endovascular treatment of abdominal aortic aneurysm using magnetic resonance imaging with a blood pool contrast agent: preliminary observations.

    NARCIS (Netherlands)

    Cornelissen, Sandra; Prokop, M.; Verhagen, H.J.; Adriaensen, M.E.; Moll, F.L.; Bartels, L.W.

    2010-01-01

    OBJECTIVE: To determine whether blood pool contrast agent-enhanced magnetic resonance imaging (MRI) can visualize endoleaks that are occult on computed tomography (CT) in patients with nonshrinking aneurysms after endovascular aneurysm repair. MATERIALS AND METHODS: Written informed consent was obta

  17. Through-Plane Movement at Multiple Aortic Levels on Dynamic Computed Tomography Angiography Is Limited in Patients With an Abdominal Aortic Aneurysm

    NARCIS (Netherlands)

    de Jonge, Jeroen C; Zandvoort, Herman J A; Vonken, Evert-Jan P A; Moll, Frans L; van Herwaarden, JA

    2015-01-01

    PURPOSE: To analyze the movement of the aorta in the craniocaudal direction (through-plane movement) during the cardiac cycle at several levels to determine any potential impact on endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA). METHODS: For this study, 30 patients (median ag

  18. Liposomal bupivacaine infiltration into the transversus abdominis plane for postsurgical analgesia in open abdominal umbilical hernia repair: results from a cohort of 13 patients

    Directory of Open Access Journals (Sweden)

    Feierman DE

    2014-08-01

    Full Text Available Dennis E Feierman, Mark Kronenfeld, Piyush M Gupta, Natalie Younger, Eduard Logvinskiy Department of Anesthesiology, Maimonides Medical Center, Brooklyn, NY, USA Background: Achieving adequate control of postsurgical pain remains a challenge in patients undergoing abdominal surgery. Transversus abdominis plane (TAP infiltration has been shown to provide postsurgical analgesia following lower abdominal surgery. We assessed the safety and efficacy of a prolonged-release liposomal formulation of the local anesthetic bupivacaine administered via infiltration into the TAP in a cohort of patients undergoing open abdominal umbilical hernia repair. Methods: Patients included in the study were 18–75 years of age, had American Society of Anesthesiologists physical classification status 1–3, and underwent open abdominal umbilical hernia repair with ultrasound-guided TAP infiltration immediately after surgery using an equal-volume bilateral infusion of liposomal bupivacaine 266 mg (diluted to 30 mL in normal saline. Outcome measures included patient-reported pain intensity (11-point numeric rating scale, satisfaction with postsurgical analgesia (5-point Likert scale, incidence of opioid-related adverse events, and time to first use of supplemental rescue analgesia. Results: Thirteen patients underwent surgery and received bilateral TAP infiltration with liposomal bupivacaine; TAP infiltration failed in the first patient. Mean numeric rating scale pain scores were 0.6 immediately before TAP infiltration and remained 2.3 through 120 hours after infiltration; mean scores at 120 hours and 10 days were 0.9 and 0.4, respectively. Ten patients (77% required supplemental analgesia; median time to first use was 11 hours. At discharge and day 10, 54% and 62% of patients, respectively, were “extremely satisfied” with postsurgical analgesia (Likert score 5. There were no opioid-related or other adverse events. Conclusion: Although the current study was

  19. Multislice CT Angiography of Fenestrated Endovascular Stent Grafting for Treating Abdominal Aortic Aneurysms: a Pictorial Review of the 2D/3D Visualizations

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua [Curtin University, Perth (Australia); Mwipatayi, Bibombe P [Royal Perth Hospital, Perth (Australia); Allen, Yvonne B; Hartley, David E [Cook R and D, Perth (Australia); Lawrence-Brown, Michael M [Curtin University of Technology, Perth (Australia)

    2009-06-15

    Fenestrated endovascular repair of an abdominal aortic aneurysm has been developed to treat patients with a short or complicated aneurysm neck. Fenestration involves creating an opening in the graft fabric to accommodate the orifice of the vessel that is targeted for preservation. Fixation of the fenestration to the renal arteries and the other visceral arteries can be done by implanting bare or covered stents across the graft-artery ostia interfaces so that a portion of the stent protrudes into the aortic lumen. Accurate alignment of the targeted vessels in a longitudinal aspect is hard to achieve during stent deployment because rotation of the stent graft may take place during delivery from the sheath. Understanding the 3D relationship of the aortic branches and the fenestrated vessel stents following fenestration will aid endovascular specialists to evaluate how the stent graft is situated within the aorta after placement of fenestrations. The aim of this article is to provide the 2D and 3D imaging appearances of the fenestrated endovascular grafts that were implanted in a group of patients with abdominal aortic aneurysms, based on the multislice CT angiography. The potential applications of each visualization technique were explored and compared with the 2D axial images

  20. Type 2 Diabetes Mellitus and Thoracic Aortic Aneurysm and Dissection

    Science.gov (United States)

    Jiménez-Trujillo, Isabel; González-Pascual, Montserrat; Jiménez-García, Rodrigo; Hernández-Barrera, Valentín; de Miguel-Yanes, José Mª; Méndez-Bailón, Manuel; de Miguel-Diez, Javier; Salinero-Fort, Miguel Ángel; Perez-Farinos, Napoleón; Carrasco-Garrido, Pilar; López-de-Andrés, Ana

    2016-01-01

    Abstract To describe trends in the rates of discharge due to thoracic aortic aneurysm and dissection (TAAD) among patients with and without type 2 diabetes in Spain (2001–2012). We used national hospital discharge data to select all of the patients who were discharged from the hospital after TAAD. We focused our analysis on patients with TAAD in the primary diagnosis field. Discharges were grouped by diabetes status (diabetic or nondiabetic). Incidence was calculated overall and stratified by diabetes status. We divided the study period into 4 periods of 3 years each. We analyzed diagnostic and surgical procedures, length of stay, and in-hospital mortality. We identified 48,746 patients who were discharged with TAAD. The rates of discharge due to TAAD increased significantly in both diabetic patients (12.65 cases per 100,000 in 2001/2003 to 23.92 cases per 100,000 in 2010/2012) and nondiabetic patients (17.39 to 21.75, respectively). The incidence was higher among nondiabetic patients than diabetic patients in 3 of the 4 time periods. The percentage of patients who underwent thoracic endovascular aortic repair increased in both groups, whereas the percentage of patients who underwent open repair decreased. The frequency of hospitalization increased at a higher rate among diabetic patients (incidence rate ratio 1.14, 95% confidence interval [CI] 1.07–1.20) than among nondiabetic patients (incidence rate ratio 1.08, 95% CI 1.07–1.11). The in-hospital mortality was lower in diabetic patients than in nondiabetic patients (odds ratio 0.83, 95% CI 0.69–0.99). The incidence rates were higher in nondiabetic patients. Hospitalizations seemed to increase at a higher rate among diabetic patients. Diabetic patients had a significantly lower mortality, possibly because of earlier diagnoses, and improved and more readily available treatments. PMID:27149499

  1. Pediatric intracranial aneurysms.

    Science.gov (United States)

    Tripathy, L N; Singh, S N

    2009-01-01

    The incidence of subarachnoid haemorrhage from intracranial aneurysms in the paediatric age group is extremely rare. Interestingly, occurrence of vasospasm has been reported to be less in comparison to the adults. Both coiling and clipping have been advocated in selected cases. Because of the thinness of the wall of the arteries, utmost care should be taken while handling these arteries during surgery. The overall results of surgery in children have been reported to be better than their adult counterparts. We present four such cases from our own experience. All these children were operated upon, where the solitary aneurysm in each case was clipped and all of them made a good recovery.

  2. Surgical treatment of complicated traumatic aneurysm and arteriovenous fistula

    Institute of Scientific and Technical Information of China (English)

    乔正荣; 时德

    2003-01-01

    Objective: To evaluate the surgical methods and the outcome of management for traumatic arterial aneurysm (TAA) and traumatic arteriovenous fistula (TAVF). Methods: A total of 121 patients with TAA or TAVF were treated by surgery. Clinical, operative and postoperative data were collected and analyzed retrospectively. Results: The surgical techniques included aneurysmectomy and arterial end-to-end anastomosis or vascular grafting or artery ligation, aneurysm ligation and bypass, vascular repair, fistula excision and vascular ligation or vascular grafting or repair and so on. One patient died (0.83%). The follow-up rates of TAA and TAVF were 65.7% and 60% respectively. Conclusions: Complicated TAA and TAVF in different sites should be treated with different methods.

  3. The 'Sphere': A Dedicated Bifurcation Aneurysm Flow-Diverter Device.

    Science.gov (United States)

    Peach, Thomas; Cornhill, J Frederick; Nguyen, Anh; Riina, Howard; Ventikos, Yiannis

    2014-01-01

    We present flow-based results from the early stage design cycle, based on computational modeling, of a prototype flow-diverter device, known as the 'Sphere', intended to treat bifurcation aneurysms of the cerebral vasculature. The device is available in a range of diameters and geometries and is constructed from a single loop of NITINOL(®) wire. The 'Sphere' reduces aneurysm inflow by means of a high-density, patterned, elliptical surface that partially occludes the aneurysm neck. The device is secured in the healthy parent vessel by two armatures in the shape of open loops, resulting in negligible disruption of parent or daughter vessel flow. The device is virtually deployed in six anatomically accurate bifurcation aneurysms: three located at the Basilar tip and three located at the terminus bifurcation of the Internal Carotid artery (at the meeting of the middle cerebral and anterior cerebral arteries). Both steady state and transient flow simulations reveal that the device presents with a range of aneurysm inflow reductions, with mean flow reductions falling in the range of 30.6-71.8% across the different geometries. A significant difference is noted between steady state and transient simulations in one geometry, where a zone of flow recirculation is not captured in the steady state simulation. Across all six aneurysms, the device reduces the WSS magnitude within the aneurysm sac, resulting in a hemodynamic environment closer to that of a healthy vessel. We conclude from extensive CFD analysis that the 'Sphere' device offers very significant levels of flow reduction in a number of anatomically accurate aneurysm sizes and locations, with many advantages compared to current clinical cylindrical flow-diverter designs. Analysis of the device's mechanical properties and deployability will follow in future publications.

  4. Down syndrome: a risk factor for mycotic aneurysm?

    LENUS (Irish Health Repository)

    Naughton, Peter A

    2011-03-29

    Down syndrome, or trisomy 21, has a characteristic constellation of clinical findings, including various congenital heart defects. We report a case of an adult male with Down syndrome who presented with a 3-week history of lower limb pain and swelling, attributed to cellulitis. Clinical and angiographic evaluation identified a below-knee mycotic pseudoaneurysm secondary to infective endocarditis. Surgical aneurysmal repair and revascularization were performed. Various management options are outlined in this report.

  5. Mirror aneurysms : a reflection on natural history

    NARCIS (Netherlands)

    Meissner, Irene; Torner, James; Huston III, John; Rajput, Michele L.; Wiebers, David O.; Jones, Lyell K.; Brown, Robert D.; Groen, Rob

    2012-01-01

    OBJECT: Investigators conducting the International Study of Unruptured Intracranial Aneurysms, sponsored by the National Institutes of Health, sought to evaluate predictors of future hemorrhage in patients who had unruptured mirror aneurysms. These paired aneurysms in bilateral arterial positions mi

  6. Unoperated aortic aneurysm

    DEFF Research Database (Denmark)

    Perko, M J; Nørgaard, M; Herzog, T M;

    1995-01-01

    From 1984 to 1993, 1,053 patients were admitted with aortic aneurysm (AA) and 170 (15%) were not operated on. The most frequent reason for nonoperative management was presumed technical inoperability. Survivals for patients with thoracic, thoracoabdominal, and abdominal AA were comparable...... hypertension were predictive of mortality, whereas...

  7. Correção endovascular de aneurisma de aorta abdominal e artéria ilíaca comum esquerda em paciente com hemofilia C grave Endovascular repair of abdominal aortic aneurysm and left common iliac artery in a patient with severe hemophilia C

    Directory of Open Access Journals (Sweden)

    Sergio Quilici Belczak

    2012-03-01

    Full Text Available A deficiência do fator XI, também conhecida como hemofilia C, é uma doença hematológica hereditária rara, que se manifesta clinicamente com hemorragia persistente após cirurgias, traumas, menorragias e extrações dentárias. Neste artigo, relatou-se a correção endovascular de um paciente com aneurisma de aorta e de artéria ilíaca comum esquerda em um paciente portador de deficiência major do fator XI (atividade do fator XI inferior a 20%. O procedimento foi realizado com sucesso, com o manuseio do distúrbio da coagulação por meio da infusão de plasma fresco no pré-operatório imediato e no pós-operatório, e controle laboratorial da coagulação do paciente.Factor XI deficiency, also known as hemophilia C, is a rare hereditary blood disease that manifests with persistent bleeding after surgery, trauma, menorrhagia, and dental extractions. This article reports an endovascular repair of a patient diagnosed with an aortic and left common iliac aneurysm, with severe factor XI deficiency (factor XI activity below 20%. The procedure was successfully performed with management of the coagulation disorder by preoperative and postoperative infusion of plasma and laboratory control of the coagulation.

  8. CT of thoracic aortic aneurysms.

    Science.gov (United States)

    Posniak, H V; Olson, M C; Demos, T C; Benjoya, R A; Marsan, R E

    1990-09-01

    Aneurysms of the thoracic aorta are most often the result of arteriosclerotic disease. Other causes include degeneration of the medial layer of the aortic wall, either idiopathically or due to genetic disorders such as Marfan syndrome; aortic dissection; trauma; syphilis and other bacterial infection; noninfective aortitis; and congenital anomaly. We review normal anatomy of the aorta and discuss our technique and interpretation of computed tomography (CT) in the evaluation of the thoracic aorta. We illustrate the CT appearance of different types of aortic aneurysms as well as discuss the use of CT for assessing complications of aneurysms, for postoperative follow-up, and in the differentiation of aortic aneurysm from a paraaortic mass.

  9. Giant renal artery aneurysm: A case report.

    Science.gov (United States)

    Cindolo, Luca; Ingrosso, Manuela; De Francesco, Piergustavo; Castellan, Pietro; Berardinelli, Francesco; Fiore, Franco; Schips, Luigi

    2015-07-07

    A case of a 12 cm giant renal artery aneurysm (RAA) in an 59-year-old woman is reported. The patient was referred to our hospital for flank pain and spot hematuria. Ultrasonography (US) revealed some wide lacunar areas in her right kidney and a thin cortex. Three-dimensional computed tomography (3D-CT) revealed a giant right renal arteriovenous malformation (AVM). AngioCT scan showed a pervious right renal artery. The cavities of the right kidney were dilated and the parenchyma was markedly reduced. Two months later the patient underwent an open resection of the aneurysm and a right nephrectomy. She had an uneventful recovery and a healthy status (last follow-up: 9 month). In this particular case, a safe approach is the transabdominal approach since the aneurysm was very large, friable, and located on the right side. This report confirms the opportunity of a planned nephrectomy once there is adequate renal reserve in the opposite kidney using a midline approach.

  10. Giant renal artery aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Luca Cindolo

    2015-07-01

    Full Text Available A case of a 12 cm giant renal artery aneurysm (RAA in an 59-year-old woman is reported. The patient was referred to our hospital for flank pain and spot hematuria. Ultrasonography (US revealed some wide lacunar areas in her right kidney and a thin cortex. Three-dimensional computed tomography (3D-CT revealed a giant right renal arteriovenous malformation (AVM. AngioCT scan showed a pervious right renal artery. The cavities of the right kidney were dilated and the parenchyma was markedly reduced. Two months later the patient underwent an open resection of the aneurysm and a right nephrectomy. She had an uneventful recovery and a healthy status (last follow-up: 9 month. In this particular case, a safe approach is the transabdominal approach since the aneurysm was very large, friable, and located on the right side. This report confirms the opportunity of a planned nephrectomy once there is adequate renal reserve in the opposite kidney using a midline approach.

  11. Laparoscopic repair of femoral hernia

    OpenAIRE

    Yang, Xue-Fei; Liu, Jia-Lin

    2016-01-01

    Laparoscopic repair of inguinal hernia is mini-invasive and has confirmed effects. Femoral hernia could be repaired through the laparoscopic procedures for inguinal hernia. These procedures have clear anatomic view in the operation and preoperatively undiagnosed femoral hernia could be confirmed and treated. Lower recurrence ratio was reported in laparoscopic procedures compared with open procedures for repair of femoral hernia. The technical details of laparoscopic repair of femoral hernia, ...

  12. Parallel multiscale simulations of a brain aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, Leopold [Division of Applied Mathematics, Brown University, Providence, RI 02912 (United States); Fedosov, Dmitry A. [Institute of Complex Systems and Institute for Advanced Simulation, Forschungszentrum Jülich, Jülich 52425 (Germany); Karniadakis, George Em, E-mail: george_karniadakis@brown.edu [Division of Applied Mathematics, Brown University, Providence, RI 02912 (United States)

    2013-07-01

    Cardiovascular pathologies, such as a brain aneurysm, are affected by the global blood circulation as well as by the local microrheology. Hence, developing computational models for such cases requires the coupling of disparate spatial and temporal scales often governed by diverse mathematical descriptions, e.g., by partial differential equations (continuum) and ordinary differential equations for discrete particles (atomistic). However, interfacing atomistic-based with continuum-based domain discretizations is a challenging problem that requires both mathematical and computational advances. We present here a hybrid methodology that enabled us to perform the first multiscale simulations of platelet depositions on the wall of a brain aneurysm. The large scale flow features in the intracranial network are accurately resolved by using the high-order spectral element Navier–Stokes solver NεκTαr. The blood rheology inside the aneurysm is modeled using a coarse-grained stochastic molecular dynamics approach (the dissipative particle dynamics method) implemented in the parallel code LAMMPS. The continuum and atomistic domains overlap with interface conditions provided by effective forces computed adaptively to ensure continuity of states across the interface boundary. A two-way interaction is allowed with the time-evolving boundary of the (deposited) platelet clusters tracked by an immersed boundary method. The corresponding heterogeneous solvers (NεκTαr and LAMMPS) are linked together by a computational multilevel message passing interface that facilitates modularity and high parallel efficiency. Results of multiscale simulations of clot formation inside the aneurysm in a patient-specific arterial tree are presented. We also discuss the computational challenges involved and present scalability results of our coupled solver on up to 300 K computer processors. Validation of such coupled atomistic-continuum models is a main open issue that has to be addressed in

  13. Parallel multiscale simulations of a brain aneurysm.

    Science.gov (United States)

    Grinberg, Leopold; Fedosov, Dmitry A; Karniadakis, George Em

    2013-07-01

    Cardiovascular pathologies, such as a brain aneurysm, are affected by the global blood circulation as well as by the local microrheology. Hence, developing computational models for such cases requires the coupling of disparate spatial and temporal scales often governed by diverse mathematical descriptions, e.g., by partial differential equations (continuum) and ordinary differential equations for discrete particles (atomistic). However, interfacing atomistic-based with continuum-based domain discretizations is a challenging problem that requires both mathematical and computational advances. We present here a hybrid methodology that enabled us to perform the first multi-scale simulations of platelet depositions on the wall of a brain aneurysm. The large scale flow features in the intracranial network are accurately resolved by using the high-order spectral element Navier-Stokes solver εκαr . The blood rheology inside the aneurysm is modeled using a coarse-grained stochastic molecular dynamics approach (the dissipative particle dynamics method) implemented in the parallel code LAMMPS. The continuum and atomistic domains overlap with interface conditions provided by effective forces computed adaptively to ensure continuity of states across the interface boundary. A two-way interaction is allowed with the time-evolving boundary of the (deposited) platelet clusters tracked by an immersed boundary method. The corresponding heterogeneous solvers ( εκαr and LAMMPS) are linked together by a computational multilevel message passing interface that facilitates modularity and high parallel efficiency. Results of multiscale simulations of clot formation inside the aneurysm in a patient-specific arterial tree are presented. We also discuss the computational challenges involved and present scalability results of our coupled solver on up to 300K computer processors. Validation of such coupled atomistic-continuum models is a main open issue that has to be addressed in future

  14. Laparoscopic repair of postoperative perineal hernia.

    LENUS (Irish Health Repository)

    Ryan, Stephen

    2010-01-01

    Perineal hernias are infrequent complications following abdominoperineal operations. Various approaches have been described for repair of perineal hernias including open transabdominal, transperineal or combined abdominoperineal repairs. The use of laparoscopic transabdominal repair of perineal hernias is not well-described. We present a case report demonstrating the benefits of laparoscopic repair of perineal hernia following previous laparoscopic abdominoperineal resection (APR) using a nonabsorbable mesh to repair the defect. We have demonstrated that the use of laparoscopy with repair of the pelvic floor defect using a non absorbable synthetic mesh offers an excellent alternative with many potential advantages over open transabdominal and transperineal repairs.

  15. Reconfigurable Polymer Networks for Improved Treatment of Intracranial Aneurysms

    Science.gov (United States)

    Ninh, Chi Suze Q.

    Endovascular embolization of intracranial aneurysms is a minimally invasive treatment in which an implanted material forms a clot to isolate the weakened vessel. Current strategy suffers from long-term potential failure modes. These potential failure modes include (1) enzymatic degradation of the fibrin clot that leads to compaction of the embolic agent, (2) incomplete filling of the aneurysm sac by embolic agent, and (3) challenging geometry of wide neck aneurysms. In the case of wide neck aneurysms, usually an assisting metal stent is used to help open the artery. However, metal stents with much higher modulus in comparison to the soft blood vessel can cause biocompatibilities issues in the long term such as infection and scarring. Motivated to solve these challenges associated with endovascular embolization, strategies to synthesize and engineer reconfigurable and biodegradable polymers as alternative therapies are evaluated in this thesis. (1) Reconfiguration of fibrin gel's modulus was achieved through crosslinking with genipin released from a biodegradable polymer matrix. (2) Reconfigurability can also be achieved by transforming triblock co-polymer hydrogel into photoresponsive material through incorporation of melanin nanoparticles as efficient photosensitizers. (3) Finally, reconfigurability can be conferred on biodegradable polyester networks via Diels-Alder coupling of furan pendant groups and dimaleimide crosslinking agent. Taken all together, this thesis describes strategies to transform a broad class of polymer networks into reconfigurable materials for improved treatment of intracranial aneurysms as well as for other biomedical applications.

  16. Genetic and Epigenetic Regulation of Aortic Aneurysms

    Science.gov (United States)

    Kim, Ha Won

    2017-01-01

    Aneurysms are characterized by structural deterioration of the vascular wall leading to progressive dilatation and, potentially, rupture of the aorta. While aortic aneurysms often remain clinically silent, the morbidity and mortality associated with aneurysm expansion and rupture are considerable. Over 13,000 deaths annually in the United States are attributable to aortic aneurysm rupture with less than 1 in 3 persons with aortic aneurysm rupture surviving to surgical intervention. Environmental and epidemiologic risk factors including smoking, male gender, hypertension, older age, dyslipidemia, atherosclerosis, and family history are highly associated with abdominal aortic aneurysms, while heritable genetic mutations are commonly associated with aneurysms of the thoracic aorta. Similar to other forms of cardiovascular disease, family history, genetic variation, and heritable mutations modify the risk of aortic aneurysm formation and provide mechanistic insight into the pathogenesis of human aortic aneurysms. This review will examine the relationship between heritable genetic and epigenetic influences on thoracic and abdominal aortic aneurysm formation and rupture. PMID:28116311

  17. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    Energy Technology Data Exchange (ETDEWEB)

    Barwick, Tara D. [Imperial College Healthcare NHS Trust, Charing Cross Hospital, Department of Radiology/Nuclear Medicine, London (United Kingdom); Hammersmith Hospital, Department of Surgery and Cancer, Imperial College London, London (United Kingdom); Lyons, O.T.A.; Waltham, M. [King' s College London, BHF Centre of Research Excellence and NIHR Biomedical Research Centre at King' s Health Partners, Academic Department of Surgery, London (United Kingdom); Mikhaeel, N.G. [Guy' s and St Thomas' Foundation NHS Trust, Department of Oncology, London (United Kingdom); O' Doherty, M.J. [King' s Health Partners, Clinical PET Centre, St Thomas' Hospital, London (United Kingdom)

    2014-12-15

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[{sup 18}F] fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal (<3 cm diameter) controls from the same population was assessed. Infra-renal aortic wall FDG uptake was assessed using visual analysis; maximum standardized uptake value (SUV{sub max}) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV{sub max} was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by {sup 18}F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls

  18. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge G; Grønbæk, Morten

    2012-01-01

    General Population Study, respectively. According to the magnitude of the hazard ratios, tobacco consumption was the most important risk factor for hospitalization and death from aortic aneurysm, followed by male sex and hypertension in both cohorts. The population attributable risk of aortic aneurysm...... outcomes due to tobacco consumption was 64% and 47% in the Copenhagen City Heart Study and Copenhagen General Population Study, respectively, and ranked highest among population attributable risks of aortic aneurysm in both cohorts. The absolute 10-year risk for hospitalization or death from aortic......BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...

  19. Clip reconstruction of a large right MCA bifurcation aneurysm. Case report

    Directory of Open Access Journals (Sweden)

    Giovani A.

    2014-06-01

    Full Text Available We report a case of complex large middle cerebral artery (MCA bifurcation aneurysm that ruptured during dissection from the very adherent MCA branches but was successfully clipped and the MCA bifurcation reconstructed using 4 Yasargill clips. Through a right pterional craniotomy the sylvian fissure was largely opened as to allow enough workspace for clipping the aneurysm and placing a temporary clip on M1. The pacient recovered very well after surgery and was discharged after 1 week with no neurological deficit. Complex MCA bifurcation aneurysms can be safely reconstructed using regular clips, without the need of using fenestrated clips or complex by-pass procedures.

  20. Successful endovascular treatment of a growing megadolichoectasic vertebrobasilar artery aneurysm by flow diversion using the "diverter-in-stent" technique.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Moscovici, Samuel; Itshayek, Eyal

    2012-01-01

    Giant dolichoectatic and fusiform aneurysms of the vertebrobasilar artery are among the most difficult and dangerous aneurysms to treat. Conservative management may be reasonable in asymptomatic elderly patients. Nevertheless, due to the frequent presence of mass effect on the brainstem and the risks of thromboembolic events and rupture, these aneurysms often demand treatment rather than observation. With the advancement of endovascular techniques some of these lesions have become treatable without the high morbidity and mortality rates associated with open surgical treatment. When dealing with giant, progressively enlarging symptomatic aneurysms, more limited therapeutic alternatives are available. The authors present a case of a growing megadolichoectatic vertebrobasilar artery aneurysm causing major disability due to increasing mass effect in a 51-year-old man. The aneurysm was treated with flow diversion by placing multiple telescoped stents and diverters ("diverter-in-stent" technique), achieving thrombosis of the aneurysm and reduction of the mass effect on the brainstem, with neurological improvement. The successful clinical and angiographic results observed in our case of giant dolichoectasic vertebrobasilar aneurysm contribute to the literature on giant aneurysms treated by means of flow diversion.

  1. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553......, 78% stated that their quality of life had improved or was unchanged after surgery and had resumed working. These data justify a therapeutically aggressive approach, including ICU therapy following AAA surgery, despite failure of one or more organ systems....

  2. Idiopathic pulmonary artery aneurysm.

    Science.gov (United States)

    Kotwica, Tomasz; Szumarska, Joanna; Staniszewska-Marszalek, Edyta; Mazurek, Walentyna; Kosmala, Wojciech

    2009-05-01

    Pulmonary artery aneurysm (PAA) is an uncommon lesion, which may be associated with different etiologies including congenital cardiovascular diseases, systemic vasculitis, connective tissue diseases, infections, and trauma. Idiopathic PAA is sporadically diagnosed by exclusion of concomitant major pathology. We report a case of a 56-year-old female with an idiopathic pulmonary artery dilatation identified fortuitously by echocardiography and confirmed by contrast-enhanced computed tomography. Neither significant pulmonary valve dysfunction nor pulmonary hypertension and other cardiac abnormalities which might contribute to the PAA development were found. Here, we describe echocardiographic and computed tomography findings and review the literature on PAA management.

  3. Battle of the Bulge: Aortic Aneurysm Management From Early Modernity to the Present.

    Science.gov (United States)

    Barr, Justin

    2017-02-21

    For centuries, physicians have recognized aortic aneurysms as an acute threat to life. Therapeutic approaches to the disease began in the 18th century when leading physicians, such as René Laennec and Antonio Valsalva, applied research on circulation and blood coagulation to devise whole-body fasting and bleeding regimens to prevent rupture. After John Hunter's success in ligating arteries to treat peripheral aneurysms, surgeons attempted analogous operations on the aorta, but even the renowned Sir Astley Cooper and William Halsted met with disastrous results. Other clinicians tried various methods of creating intraluminal clots, including the application of such new technologies as electricity and plastic. Vessel repair techniques, pioneered by Alexis Carrel and others in the 20th century, eventually provided a reliably effective treatment. In the past few decades, minimally invasive methods that approach aneurysms endovascularly through small groin incisions have been adopted. A successful 2005 congressional campaign to fund screening for aortic aneurysms brought the disease to national attention and symbolizes current confidence in curing it. Drawing on various published and unpublished sources, this paper elucidates the development of specific treatments for aortic aneurysms over time and more broadly addresses how medicine and surgery apply the knowledge and technology available in particular eras to treat a specific, identifiable, and lethal disease. Examining the evolution of these therapeutic efforts unveils broader trends in the history of medicine. This allows aortic aneurysms to serve as a case study for exploring shifting philosophies in medical history.

  4. Endovascular repair of acute AAAs under local anesthesia with bifurcated endografts : A feasibility study

    NARCIS (Netherlands)

    Verhoeven, ELG; Prins, TR; van den Dungen, JJAM; Tielliu, IFJ; Hulsebos, RG; van Schilfgaarde, R

    2002-01-01

    Purpose: To evaluate endovascular repair of abdominal aortic aneurysms (AAA) under local anesthesia in the acute setting. Methods: Between 1998 and 2001, 47 patients with an acute AAA were evaluated for endovascular repair after informed consent, provided they were in a stable, albeit hypotensive co

  5. Microsurgical management of posterior circulation aneurysms

    Directory of Open Access Journals (Sweden)

    SHI Xiang-en

    2012-02-01

    Full Text Available Objective To retrospectively analyze effective methods for surgical management of posterior circulation aneurysms. Methods There were 42 patients with posterior circulation aneurysms [26 cases of basilar aneurysm (27 aneurysms, 16 cases of vertebral aneurysm (17 aneurysms]. There were 15 patients underwent bypass surgery [4 external carotid artery-P2 segment of posterior cerebral artery (ECA-P2, 2 internal carotid artery-P2 segment of posterior cerebral artery (ICA-P2, 2 internal maxillary artery-P2 segment of posterior cerebral artery (IMA-P2, 2 intracranial segment of vertebral artery-extracranial segment of vertebral artery, 5 occipital artery-posterior inferior cerebellar artery (OA-PICA] and 27 patients underwent simple surgical clipping. Results Activities of daily life of 37 patients recovered to normal (14 patients with aneurysm on the top of basilar artery, 3 with aneurysm on the trunk of basilar artery, 9 with vertebral aneurysm, 5 with posterior inferior cerebellar artery aneurysm, 4 with aneurysm on the junction of P1-P2 segment of posterior cerebral artery, 1 with superior cerebellar artery, and 1 with anterior inferior cerebellar aneurysm. None of them occurred operation-related neurological dysfunction. The recovery rate was 88.09% . Among the other patients, 1 with aneurysm on the top of basilar artery presented severe signs and symptoms of neurological defect and cannot take care of oneself, 2 patients (1 with aneurysm on the top of basilar artery, 1 with aneurysm on the trunk of basilar artery occurred brain stem hemorrhage after operation, and died at perioperative period, 2 with vertebral aneurysm relapsed and was cured after treatment. Conclusion Posterior circulation aneurysm which is not suitable for surgical clipping can be treated with intra? and extra?cranial vessel bypass. It may avoid the risk of surgical clipping of aneurysm.

  6. Subject-specific modeling of intracranial aneurysms

    Science.gov (United States)

    Cebral, Juan R.; Hernandez, Monica; Frangi, Alejandro; Putman, Christopher; Pergolizzi, Richard; Burgess, James

    2004-04-01

    Characterization of the blood flow patterns in cerebral aneurysms is important to explore possible correlations between the hemodynamics conditions and the morphology, location, type and risk of rupture of intracranial aneurysms. For this purpose, realistic patient-specific models are constructed from computed tomography angiography and 3D rotational angiography image data. Visualizations of the distribution of hemodynamics forces on the aneurysm walls as well as the intra-aneurysmal flow patterns are presented for a number of cerebral aneurysms of different sizes, types and locations. The numerical models indicate that there are different classes of intra-aneurysmal flow patterns, that may carry different risks of rupture.

  7. Development of bilateral coronary artery aneurysms in a child with Noonan syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Mauro, David M.; Flors, Lucia; Norton, Patrick T.; Hagspiel, Klaus D. [University of Virginia Health System, Department of Radiology and Medical Imaging, Charlottesville, VA (United States); Hoyer, Andrew W. [University of Virginia Health System, Department of Pediatrics, Division of Pediatric Cardiology, Charlottesville, VA (United States); Pediatric Cardiology Center of Oregon, Portland, OR (United States)

    2016-03-15

    Noonan syndrome is a constellation of congenital malformations including heart defects, facial anomalies and short stature. The cardiovascular defects are variable and extensive, with the most common being pulmonary stenosis and hypertrophic cardiomyopathy. Coronary artery anomalies have only been reported in a few cases. We report a child with Noonan syndrome status post pulmonary stenosis and atrial septal defect repair, who developed bilateral coronary artery aneurysms. The aneurysms were diagnosed with both cardiac magnetic resonance imaging and coronary computed tomography angiography. There had been no evidence of them on a cardiac MR exam 5 years previously. (orig.)

  8. Three-dimensional Ultrasound in the Management of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Lowe, C; Ghulam, Q; Bredahl, K

    2016-01-01

    Three-dimensional (3D) ultrasound is an evolving modality that may have numerous applications in the management of abdominal aortic aneurysms. Many vascular specialists will not be familiar with the different ways in which 3D vascular ultrasound data can be acquired nor how potential applications...... are being explored by researchers. Most of the current literature consists of small series and single-centre experience, although clinical themes such as measurement of abdominal aortic aneurysm volume and surveillance following endovascular repair are emerging. The aim of this topical review...

  9. Epicardial radiofrequency ablation for left ventricular aneurysm related ventricular arrhythmias during off-pump coronary artery bypass surgery

    Institute of Scientific and Technical Information of China (English)

    YU Yang; GAO Ming-xin; LI Hai-tao; ZHANG Fan; GU Cheng-xiong

    2012-01-01

    Background Left ventricular aneurysm (LVA) is one of the serious complications after acute myocardial infarction.We attempted to evaluate the preliminary efficacy of LVA repair combined with epicardial radiofrequency ablation for ventricular arrhythmia during off-pump coronary artery bypass grafting (OPCAB).Methods From June 2009 to April 2011,31 patients with LVA had angina symptoms and ventricular arrhythmia.In all patients,circular and cross-shaped radiofrequency epicardial ablations were performed using unipolar ablation pen along the border between the aneurysm wall and normal cardiac tissue and in the central zone of the aneurysms,followed by a linear placation of ventricular aneurysms on beating heart.Results All the patients showed complete recovery.The average number of grafted vessels was 2.7±1.3.Intraoperative examinations revealed that the ventricular arrhythmia was effectively controlled by radiofrequency ablation.All cases had been followed up for one year.Holter monitoring revealed a significant reduction in ventricular arrhythmias (P <0.05).Echocardiography showed significant increase in left ventricular ejection fraction (P <0.05) and decrease in left ventricular end-diastolic diameter (P <0.05).Conclusions For patients with ventricular aneurysm and preoperative malignant arrhythmia,aneurysm repair plus epicardial radiofrequency ablation in OPCAB was found to be an effective and feasible therapeutic technique.However,medium-to long-term therapeutic efficacy of this method remains to be determined by future studies and observations.

  10. Comparative study of laparoscopic repair of inguinal hernia and open tension-free hernia repair in the treatment of adult inguinal hernia%腹腔镜经腹膜前疝修补术与开放式无张力疝修补术治疗成人腹股沟疝的对比研究

    Institute of Scientific and Technical Information of China (English)

    张卫东

    2016-01-01

    目的:探讨腹腔镜经腹膜前疝修补术与开放式无张力疝修补术治疗成人腹股沟疝的效果。方法:收治腹股沟疝患者46例,随机分成观察组(腹腔镜经腹膜前疝修补术)和对照组(开放式无张力疝修补术)各23例。结果:观察组患者住院时间和并发症发生率与对照组相比,差异有统计学意义(P<0.05)。结论:采用腹腔镜经腹膜前疝修补术方式治疗腹股沟疝效果显著,对患者造成的创伤比较小。%Objective:To investigate the effect of laparoscopic repair of inguinal hernia and open tension-free hernia repair in the treatment of adult inguinal hernia.Methods:46 patients with inguinal hernia were selected.They were randomly divided into the observation group(laparoscopic repair of inguinal hernia) and the control group(open tension-free hernia repair) with 23 cases in each group.Results:The hospitalization time and the incidence of complications of the observation group were significantly different(P<0.05).Conclusion:The effect of laparoscopic repair of inguinal hernia in the treatment of inguinal hernia is significant, and the trauma is relatively small.

  11. Biomechanical and Clinical Studies in EndoVascular Aortic Repair

    NARCIS (Netherlands)

    Nauta, FJH

    2016-01-01

    Objectives This thesis investigates biomechanical and clinical performances of endovascular repair for thoracic aortic dissection (AD) and aneurysm. Insights from both medical and bio-engineering perspectives are pursued with the aim of providing scientific data that will help guide endovascular aor

  12. Clinical presentation of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Cianfoni, Alessandro [Neurocentro della Svizzera Italiana, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); Pravatà, Emanuele, E-mail: emanuele.pravata@gmail.com [Neurocentro della Svizzera Italiana, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); De Blasi, Roberto [Neurocentro della Svizzera Italiana, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); Tschuor, Costa Silvia [Dipartimento di Radiologia, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); Bonaldi, Giuseppe [U.O. Neuroradiologia, Ospedali Riuniti di Bergamo, Largo Barozzi, 1, 24128 Bergamo (Italy)

    2013-10-01

    Presentation of a cerebral aneurysm can be incidental, discovered at imaging obtained for unrelated causes, can occur in the occasion of imaging obtained for symptoms possibly or likely related to the presence of an unruptured aneurysm, or can occur with signs and symptoms at the time of aneurismal rupture. Most unruptured intracranial aneurysms are thought to be asymptomatic, or present with vague or non-specific symptoms like headache or dizziness. Isolated oculomotor nerve palsies, however, may typically indicate the presence of a posterior circulation aneurysm. Ruptured intracranial aneurysms are by far the most common cause of non-traumatic subarachnoid hemorrhage and represent a neurological emergency with potentially devastating consequences. Subarachnoid hemorrhage may be easily suspected in the presence of sudden and severe headache, vomiting, meningism signs, and/or altered mental status. However, failure to recognize milder and more ambiguous clinical pictures may result in a delayed or missed diagnosis. In this paper we will describe the clinical spectrum of unruptured and ruptured intracranial aneurysms by discussing both typical and uncommon clinical features emerging from the literature review. We will additionally provide the reader with descriptions of the underlying pathophysiologic mechanisms, and main diagnostic pitfalls.

  13. [False aneurysm of the left ventricle and coronary aneurysms in Behçet disease].

    Science.gov (United States)

    Rolland, J M; Bical, O; Laradi, A; Robinault, J; Benzidia, R; Vanetti, A; Herreman, G

    1993-09-01

    A false left ventricular aneurysm and coronary artery aneurysm were discovered in a 29 year old patient with Behçet's syndrome. The operation under cardiopulmonary bypass consisted of closing the neck of the false aneurysm by an endo-aneurysmal approach with a Gore-Tex patch. The coronary artery aneurysms were respected. There were no postoperative complications. Cardiac involvement is rare in Behçet's syndrome (6%). The originality of this case is the association of two aneurysmal pathologies: the coronary and ventricular aneurysms due to the angiitis and the myocardial fragility induced by ischaemia.

  14. Real time three-dimensional transthoracic echocardiography of ruptured left sinus of Valsalva aneurysm to left ventricle.

    Science.gov (United States)

    Kharwar, Rajiv Bharat; Narain, Varun Shankar; Sethi, Rishi

    2013-11-01

    Aneurysms arising from the sinus of Valsalva are a rare cardiac defect that can present with various signs and symptoms, and if not diagnosed and treated rapidly can lead to fatal outcomes. Unruptured aneurysms are usually asymptomatic and found incidentally during diagnostic studies. More commonly, aneurysm of sinus of Valsalva is detected after the occurrence of rupture. Echocardiography has become the investigative tool of choice for this condition, not only for diagnosis but also for quantification of severity. We hereby report a rare case of a 15-year-old patient presenting with complaints of effort dyspnea and palpitations. Two-dimensional transthoracic echocardiography (TTE) showed aneurysmal dilatation of left sinus of Valsalva which had ruptured into the left ventricle. Also, there was an intimal flap within the sinus of Valsalva aneurysm. The anatomical relationship between the aorta, aneurysm, and the left ventricle as well as the intimal flap within the aneurysm was clearly delineated with the help of three-dimensional TTE. After confirmation of the diagnosis with multidetector computed tomography, patient underwent successful surgical repair of the defect.

  15. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Lotfi, S., E-mail: shamim.lotfi@kcl.ac.uk; Clough, R. E.; Ali, T. [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom); Salter, R. [Guy' s and St. Thomas' NHS Trust, Interventional Radiology (United Kingdom); Young, C. P. [Guy' s and St. Thomas' NHS Trust, Cardiac Surgery (United Kingdom); Bell, R.; Modarai, B.; Taylor, P., E-mail: peter.taylor@gstt.nhs.uk [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom)

    2013-02-15

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997-2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18-90) years with mean follow-up of 15 (range, 0-61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  16. Fatores envolvidos na migração das endopróteses em pacientes submetidos ao tratamento endovascular do aneurisma da aorta abdominal Factors involved in the migration of endoprosthesis in patients undergoing endovascular aneurysm repair

    Directory of Open Access Journals (Sweden)

    Marcelo José de Almeida

    2010-06-01

    endoprosthesis regarding a certain anatomic region is verified. Considering the aneurysm of the infrarenal abdominal aorta, the proximal area of reference is the origin of the lowest renal artery and, at the distal region, it is located next to the internal iliac arteries. Patients should be monitored for long periods so that migrations can be identified; these migrations usually occur 2 years after the implantation. To avoid migrations, mechanical forces that enable fixation and that are determined by the characteristics of the devices and by the incorporation of the endoprosthesis should predominate over gravitational and hemodynamic forces, which tend to drag the prosthesis toward to caudal direction. Angulation, extension, and diameter of the neck, and transversal measure of the aneurysmatic sac are important morphological aspects related to migration. In relation to the technique, endoprosthesis implantation with excessive oversizing (> 30% is not recommended because it leads to aortic neck dilatation, folds and proximal leakage that also contribute to migration. On the other hand, endoprosthesis with additional fixation devices (hooks, barbs and suprarenal fixation seem to be less associated with migration. The process of endoprosthesis incorporation is partial and does not seem to be enough to prevent later migrations. In this sense, experimental studies with endoprosthesis of higher porosity, as well as the use of substances that allow higher fibroplasia and adherence of the prosthesis to the artery, have been conducted and are promising. Such aspects are discussed in the present review of the literature.

  17. Treatment of Complex Intracranial Aneurysms Using Flow-Diverting Silk® Stents

    Science.gov (United States)

    Buyukkaya, Ramazan; Kocaeli, Hasan; Yildirim, Nalan; Cebeci, Hakan; Erdogan, Cüneyt; Hakyemez, Bahattin

    2014-01-01

    Summary This study describes the peri-procedural and late complications and angiographic follow-up results of 32 patients with 34 complex aneurysms treated with flow diverter Silk stents in a single centre. In this retrospective study, 40 Silk stents (SS) were implanted in 34 complex intracranial aneurysms in 32 patients. In our series, 20 (58.8%) carotid-ophthalmic internal carotid artery (ICA), six (17.6%) cavernous ICA, two (5.9%) supraclinoid ICA, two (5.9%) petrosal ICA (the same patient- bilateral) and four (11.8%) posterior circulation aneurysms were treated. One of the posterior circulation lesions was a fenestrated-type aneurysm. Twenty wide-necked, saccular; eight neck remnant; four fusiform and two blister-like aneurysms were included in our series. SS were successfully implanted in all patients (100%). Misdeployment occurred in 17.6% of patients. In two of these patients adequate stent openness was achieved via Hyperglide balloon dilatation. Coil embolization in addition to SS placement was utilized in four aneurysms. One patient (3%) experienced transient morbidity due to a thromboembolic event and there was one mortality (3%) due to remote intraparenchymal haemorrhage. Complete occlusion of 27/33 (81.8 %) and 29/33 (87.9 %) aneurysms was achieved six and 12 months after the procedure, respectively. In-stent intimal hyperplasia was detected in 6.1 % patients. Flow-diverter Silk stent implantation is an effective method of treating complex aneurysms with acceptable mortality and morbidity rates. Complete occlusion is achieved in most of the complex aneurysms. PMID:25496683

  18. Intracranial aneurysm associated with relapsing polychondritis

    Energy Technology Data Exchange (ETDEWEB)

    Coumbaras, M.; Boulin, A.; Pierot, L. [Dept. of Neuroradiology, Hopital Foch, Suresnes (France); Piette, A.M.; Bletry, O. [Dept. of Medicine, Hopital Foch, Suresnes (France); Graveleau, P. [Dept. of Neurology, Hopital Foch, Suresnes (France)

    2001-07-01

    We describe a 50-year-old man with relapsing polychondritis (RP) involving auricular cartilage, uveitis and hearing loss, who had an aneurysm of the anterior cerebral artery. Intracranial aneurysm is a rare manifestation of RP. (orig.)

  19. A histopathologic study of retinal arterial aneurysms.

    Science.gov (United States)

    Fichte, C; Streeten, B W; Friedman, A H

    1978-04-01

    An isolated retinal arterial aneurysm was found postmortem in the eye of a 75-year-old hypertensive woman, and multiple aneurysms were in the enucleated eye of a 68-year-old hypertensive man with neovascular glaucoma. The aneurysmal sites showed thickening of the vessel walls with hyaline, fibrin, and foamy macrophages. Fresh or organized thrombus partially filled the aneurysmal lumina. Trypsin digestion preparations in Case 2 showed a progressive severity of aneurysmal changes from the simplest "cuff" type to the hemorrhagic "b;pwout" aneurysms with a linear split in the vessel wall. Atheroma was present in the larger arterial branches and fat was in most of the aneurysmal walls. These findings suggested that damage to the arterial wall by cholesterol or other emboli, or by occlusive disease, may predispose especially hypertensive patients to arterial aneurysm formation.

  20. Tendon repair

    Science.gov (United States)

    Repair of tendon ... Tendon repair can be performed using: Local anesthesia (the immediate area of the surgery is pain-free) ... a cut on the skin over the injured tendon. The damaged or torn ends of the tendon ...

  1. Abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal

    2010-01-01

    Although the number of elective operations for abdominal aortic aneurysms (AAA) is increasing, the sex- and age-standardised mortality rate of AAAs continues to rise, especially among men aged 65 years or more. The lethality of ruptured AAA continues to be 80-95%, compared with 5-7% by elective....... The acceptance rate was 77%, and 95% accept control scans. Furthermore, persons at the highest risk of having an AAA attend screening more frequently. We found that 97% of the interval cases developed from aortas that initially measured 2.5-2.9 cm - i.e. approx. only 5% attenders need re-screening at 5-year...... methods for measuring the degree of wall calcification must be developed and validated....

  2. Characterization of the inflammatory cells in ascending thoracic aortic aneurysms in patients with Marfan syndrome, familial thoracic aortic aneurysms and sporadic aneurysms

    Science.gov (United States)

    He, Rumin; Guo, Dong-Chuan; Sun, Wei; Papke, Christina L.; Duraisamy, Senthil; Estrera, Anthony L.; Safi, Hazim J.; Ahn, Chul; Buja, L. Maximilian; Arnett, Frank C.; Zhang, Jingwu; Geng, Yong-Jian; Milewicz, Dianna M.

    2008-01-01

    Objectives This study sought to characterize the inflammatory infiltrate in ascending thoracic aortic aneurysm (TAAs) in patients with Marfan syndrome (MFS), familial TAA (FTAA), and non-familial TAA cases. Background TAAs are associated with a pathologic lesion termed medial degeneration, which was described as a noninflammtory lesion. TAAs are a complication of MFS and also can be inherited in an autosomal dominant manner of FTAA. Methods Full aortic segments were collected from patients undergoing elective repair with MFS (n=5), FTAA (n=6) and TAAs (n=9), along with control aortas (n=5). Immunohistochemistry staining was performed using antibodies directed against markers of lymphocytes and macrophages. Real-time PCR analysis was performed to quantify the expression level of T cell receptor β chain variable region gene. Results Immunohistochemisty of TAA aortas demonstrated that the media and adventitia from MFS, FTAA and sporadic cases had increased numbers of T lymphocytes and macrophages when compared with control aortas. The number of T cells and macrophages in the aortic media of the aneurysm correlated inversely with the patient’s age at the time of prophylactic surgical repair of the aorta. Surprisingly, T cell receptor profiling indicated a similar clonal nature of the T cells in the aortic wall in a majority of aneurysms, whether the patient had MFS, FTAA or sporadic disease. Conclusion These results indicate that infiltration of inflammatory cells contributes to the pathogenesis of TAAs. Superantigen-driven stimulation of T lymphocytes in the aortic tissues of the TAA patients may contribute to the initial immune response. Ultramini-Abstract This study sought to investigate the infiltration of T-lymphocytes and macrophage in the aortas of patients with MFS, FTAA and sporadic TAAs. The results indicate that infiltration of inflammatory cells contributes to the pathogenesis of TAAs and superantigen-driven stimulation of T-lymphocytes may contribute to

  3. Surveillance intervals for small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Bown, Matthew J; Sweeting, Michael J; Brown, Louise C

    2013-01-01

    Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture.......Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture....

  4. Adult aortic coarctation discovered incidentally after the rupture of sinus of Valsalva aneurysm: combined surgical and interventional approach.

    Science.gov (United States)

    Ouali, Sana; Kortas, Chokri; Brockmeier, Konrad; Boughzela, Essia

    2011-12-01

    Combination of ruptured sinus of Valsalva aneurysm (SVA), and a coexisting asymptomatic adult aortic isthmic coarctation is extremely rare. The timing and sequence of surgical and/or interventional repair of these two pathologies are controversial. We present a case of a 37-year-old male who was admitted to our department because of severe acute congestive heart failure and signs of ruptured aneurysm of the SV into the right ventricle. Transthoracic and transoesophageal echocardiography confirmed the communication between an important right coronary SVA and right ventricle, bicuspid aortic valve, mild aortic regurgitation, and revealed severe aortic coarctation. Because of the severe dilation of right sinus of Valsalva a surgical repair of the ruptured aneurysm was performed. Aortic coarctation was treated four weeks later by a percutaneous stent-graft implantation. This case report supports the concept that hybrid approach is feasible in patients with ruptured SVA and aortic coarctation in adulthood.

  5. Saphenous vein graft true aneurysms: Report of nine cases and review of the literature

    Directory of Open Access Journals (Sweden)

    Davidović Lazar B.

    2004-01-01

    Full Text Available INTRODUCTION The true aneurysm formation of the autogenous saphenous vein graft (ASVG is a very rare complication after bypass surgery [1 -5]. In 1969 Pillet [1] first described a true fusiform aneurysm formation of the ASVG which had been used as a replacement of the iwured superficial femoral artery in 26-year-old male patient. We present nine cases. CASE!. A 71-year-old man with previous history of arterial hypertension and higher serum lipid level, was admitted with an asymptomatic pulsating swelling of the medial portion on the thigh. Five years ago the bellow knee F-P bypass with ASVG due to occlusive disease has been performed. The transfemoral angiography (Figure 1 showed patent graft with fusiform true aneurysm formation at its mid portion. This aneurysm has been replaced with PTFE graft. The pathohistological examination showed an atherosclerotic origin of the aneurysm. This patient died four years after operation due to myocardial infarction with patent graft. CASE 2. A 57-year-old female with previous history of arterial hypertension and higher serum lipid level, had an elective resection and replacement of the superficial femoral artery aneurysm. For the reconstruction an ASVG was used. The saphenous vein showed postflebitic changes. Four years later she was admitted with asymptomatic pulsating mass of the mid portion of the thigh. The control transfemoral angiography showed patent graft with fusiform aneurysm formation of its mid portion. After aneurismal resection, an above knee F-P bypass with 8 mm PTFE graft was performed. A pathohistological examination showed a partially degenerated elastic membrane with fragmentation and disruption, without atherosclerosis (Figure 2. During the follow up period an elective resection of the subclavian artery aneurysm as well as abdominal aortic aneurysm, were performed. CASE3. A subclavian artery aneurysm caused by TOS has been repaired with sapehnous vein graft at 40-year-old female patient

  6. Gigantic unruptured sinus of Valsalva aneurysm presenting as an incidental murmur.

    LENUS (Irish Health Repository)

    Yagoub, Hatim

    2012-01-01

    We report a case of a 56-year-old man referred by his family physician with an asymptomatic cardiac murmur. Trans-thoracic echocardiography (TTE) suggested an unruptured right sinus of Valsalva aneurysm (SVA) causing extrinsic compression of the right ventricular outflow tract. This was confirmed with an ECG-gated cardiac CT showing a large right SVA measuring 35×37×42 mm in size. Coronary angiography demonstrated non-obstructive coronary artery disease. Ascending thoracic anterior in the right anterior oblique view delineated the right SVA. The patient underwent aortic valve sparing surgical repair of the aneurysm with an excellent result. Echocardiography confirmed obliteration of the aneurysm and normal aortic valve function postoperatively.

  7. Phase contrast MRI in intracranial aneurysms

    NARCIS (Netherlands)

    van Ooij, P.

    2012-01-01

    Intracranial aneurysms are outpouchings of intracranial arteries that cause brain hemorrhage after rupture. Unruptured aneurysms can be treated but the risk of treatment may outweigh the risk of rupture. Local intra-aneurysmal hemodynamics can contribute substantially to the rupture risk estimation

  8. [Albert Einstein and his abdominal aortic aneurysm].

    Science.gov (United States)

    Cervantes Castro, Jorge

    2011-01-01

    The interesting case of Albert Einstein's abdominal aortic aneurysm is presented. He was operated on at age 69 and, finding that the large aneurysm could not be removed, the surgeon elected to wrap it with cellophane to prevent its growth. However, seven years later the aneurysm ruptured and caused the death of the famous scientist.

  9. Paraclinoid aneurysm concealed by sphenoid wing meningioma.

    Science.gov (United States)

    Petrecca, Kevin; Sirhan, Denis

    2009-02-01

    The coexistence of brain tumours and aneurysms is rare. In all previously reported cases the aneurysm was detectable by angiography. We report here a case in which a paraclinoid internal carotid artery aneurysm was coexistent and concealed from angiographic detection by an adjacent parasellar meningioma.

  10. Emphasis on standardized treatment of abdominal aortic aneurysm%重视腹主动脉瘤规范化治疗

    Institute of Scientific and Technical Information of China (English)

    吴庆华

    2012-01-01

    腹主动脉瘤(abdominal aortic aneurysm,AAA)破裂后病死率极高,早期发现和规范化治疗极为关键.相对于传统的开放手术(OR),AAA的腔内修复术(EVAR)具有微创性,近年由于器材的不断改进,在一些国家和医学中心已迅速开展并推广.目前,存在EVAR适应证把握不一致、忽视AAA的传统手术、治疗过程没有严格规范、随访还需亟待加强等问题.因此,为了AAA治疗的健康和快速发展,需要大力加强AAA规范化治疗.%The mortality rate was high when the abdominal aortic aneurysm (AAA) ruptured, so early detection and standardized treatment are critical. Compared with traditional open surgery (OR), AAA endovascular aneurysm repair (EVAR) developed rapidly due to the continuous improvement of equipment in recent years. For minimally invasive of EVAR procedure, it has been developed rapidly in some countries and medical centers. But there are still some problems such as indications inconsistent in different centers, ignoring the traditional surgery of the AAA, not strictly regulate the course of treatment, followup needs to be strengthened and so on. For the healthy and rapid development of the AAA treatment, it requires a substantial strengthening of the standardized treatment of AAA.

  11. Classical surgical approach and treatment with clips of extracranial internal carotid artery berry aneurysm

    Directory of Open Access Journals (Sweden)

    Haris Vukas

    2016-06-01

    Full Text Available Introduction: We can define extracranial carotid artery aneurysm (ECAA as bulb dilatation greater than 200% of the diameter of the internal carotid artery (ICA or in a case of common carotid artery (CCA greater than 150% of the diameter. Surgical intervention is required for the treatment of this disease.Case report: This study presents an open vascular surgical procedure to resolve ECAA. We report a case of 61 years old woman with an extracranial internal carotid artery berry aneurysm, presented with a headache and dizziness when turning the head aside. Classic open surgery was performed and the lumen of berry aneurysm was separated with three clips from the lumen of ICA.Conclusions: The open surgical approach is the method of choice for the treatment of extracranial internal carotid artery pathological conditions.

  12. Retrospective Contol Study on Laparoscopic Versus Open Repair of the Perforated Peptic Ulcer%腹腔镜下胃十二指肠溃疡穿孔修补术的疗效分析

    Institute of Scientific and Technical Information of China (English)

    陈刚; 黎杨浩

    2016-01-01

    Objective To explore the safety and efficacy of laparoscopic repair of the perforated gastroduodenal ulcer. Methods Between January 2011 and June 2015, we identified 112 patients with perforated peptic ulcer, among them, 63 cases repaired by laparoscopy and 49 cases treated by open method. The clinic data of the two groups were compared. Results There were no death in two groups, three cases converted to open operation. The mean operation time of laparoscopic group and open group were(74.85±15.8)min and(62.97±12.14)min respectively( <0.001). Open group had a significantly higher proportion of patients received analgesics than laparoscopic group ( <0.001). There were no significant difference between the two groups in the rate of intra-abdominal abscess, leakage of the repaired side, pulmonary infection and hospital stay. Conclusion Laparoscopic repair of the perforated gastroduodenal ulcer is effective and safe, and have high application value.%目的:探讨腹腔镜技术修补溃疡病穿孔的安全性和疗效。方法2011年1月~2015年6月行胃十二指肠溃疡穿孔修补患者112例﹐其中腹腔镜下修补63例﹐开腹手术修补49例﹐对照两组患者的手术和术后情况。结果两组患者均无围手术期死亡﹐腹腔镜组有3例中转开腹手术。腹腔镜组和开腹组平均手术时间分别为(74.85±15.8)min和(62.97±12.14)min﹐差异有统计学意义(<0.001)。开腹组患者术后使用镇痛剂的比例显著高于腹腔镜组(<0.001)。两组患者术后腹腔脓肿﹑修补处漏﹑肺部感染发生率以及住院时间均无统计学显著差异。结论腹腔镜下修补胃十二指肠溃疡穿孔有效﹑安全﹐具有较高的临床应用价值。

  13. The application of oral enteralnutrition support for senior abdominal aortic aneurysm patients who underwent endovascular aortic repair%口服肠内营养支持在局麻下高龄腹主动脉瘤腔内覆膜支架置入术后的应用

    Institute of Scientific and Technical Information of China (English)

    曾国军; 赵纪春; 马玉奎; 黄斌; 杨轶; 袁丁; 熊飞; 陈熹阳; 吴洲鹏

    2014-01-01

    Objective To investigate the clinical value of oral enteralnutrition support (ENSURE) for senior (> 60 years) abdominal aortic aneurysm (AAA) patients who underwent endovascular aortic repair (EVAR).Methods The data of 30 senior AAA patients who underwent EVAR was restrictively reviewed.The patients were divided into two groups:Group A =15,with postoperative ENSURE,50 g,tid; Group B =15,with postoperative common food.The postoperative data were compared between two groups,including the hospital stay,infection of operative incision rate,and nutritional state in the third and seventh day after operation.Results The postoperative hospital stay and infection rate had no significant difference between two groups.The plasma albumin in group A in the third day and the seventh day were higher (P < 0.05).Conclusions ENSURE improved the nutritional status of AAA patients who underwent EVAR,and shorten postoperative hospital stays.%目的 探讨口服肠内营养支持在局麻下高龄(>60岁)腹主动脉瘤(AAA)腔内覆膜支架置入术后的应用.方法 本院2010年1月至2011年10月经腔内覆膜支架置入术治疗的高龄腹主动脉瘤患者中选取30例,分为2组,每组15例,A组术后8h给予口服肠内营养支持(安素,50 g,3次/d),B组术后8h普食.对比术后切口感染率、血浆白蛋白、术后住院时间.结果 A组患者术后第3、7天白蛋白水平高于B组(P<0.05),两组感染率及术后住院时间比较差异无统计学意义(P>0.05).结论 口服肠内营养支持可促进局麻下经腔内覆膜支架置入术治疗的高龄腹主动脉瘤患者术后恢复,提高营养状态,有利于患者恢复.

  14. Intravascular ultrasound in guiding endovascular aortic aneurysm repair-a case report of interventional therapy without contrast media%血管内超声介导下主动脉夹层腔内修复术无造影剂介入治疗1例报道

    Institute of Scientific and Technical Information of China (English)

    罗建方; 黄文晖; 谢年谨; 胡孜阳; 刘媛; 杨峻青; 范瑞新; 陈纪言

    2011-01-01

    Objectives To investigate the feasibility and clinical value of intravascular ultrasound (IVUS) in guiding endovascular aortic aneurysm repair (EVAR). Methods With EVAR procedure for a patient suffered from Standford type B aortic dissection and renal insufficiency, we utilized IVUV to guide the lumen tracking, rupture site localization, stent delivery and intra-procedure examination of anatomic result. We attempted to avoid any dose of iodic contrast. Results Zero milliliter iodic contrast was consumed in the procedure and this procedure lasted for 12S minutes. The operation was smoothly performed and anatomic result was satisfactory. No complication occurred after operation. The patient's concentration of serum creatinine did not increase within a week monitor. Conclusions IVUS guided EVAR is feasible in this patients. Iodic contrast may be avoided with the utilization of this technique and sequentially renal function be protected.%目的 探讨血管内超声代替基于造影剂的血管显影指引主动脉腔内修复术的可行性和价值.方法 我们对1例Standford B型主动脉夹层合并肾功能不全患者行主动脉腔内修复术,术中使用血管内超声指引寻腔、定位、支架释放和进行解剖学检查,全程避免使用造影剂.结果 手术使用造影剂0 mL,手术时间125 min,寻腔、定位及支架释放过程顺利.支架到位准确,扩张及贴壁良好.术后无内漏或新发夹层,无其他并发症.术后1周患者血清肌酐浓度无增高.结论在本例患者中,血管内超声代替基于造影剂的血管显影指引主动脉腔内修复术可行,该技术可能避免肾功能不全患者肾功能恶化.

  15. Proteins associated with the size and expansion rate of the abdominal aortic aneurysm wall as identified by proteomic analysis

    DEFF Research Database (Denmark)

    Urbonavicius, Sigitas; Lindholt, Jes S.; Delbosc, Sandrine

    2010-01-01

    Identification of biomarkers for the natural history of abdominal aortic aneurysms (AAA) holds the key to non-surgical intervention and improved selection for AAA repair. We aimed to associate the basic proteomic composition of AAA wall tissue with the expansion rate and size in patients with AAA....

  16. Subarachnoid hemorrhage after aneurysm surgery

    Directory of Open Access Journals (Sweden)

    Carlos Gilberto Carlotti Junior

    1996-06-01

    Full Text Available The surgical treatment of intracranial aneurysms by clipping is recognized as effective and definitive. However some cases that suffered a new subarachnoid hemorrhage (SAH some time after they were submitted to aneurysm clipping have raised doubts about the concept of "cure"after this treatment. Eleven patients previously submitted to aneurysm clipping who presented a new SAH were analyzed. The time elapsed from surgery to SAH varied from 3 to 10 years. After SAH four patients had a poor outcome. The new episode of SAH occurred due to intrinsic factors of the cerebral vasculature: 1. a weak point of the vessel wall near the previous aneurysm, 2. a weak point of another vessel far from the previous aneurysm, 3. a previous infundibular dilation of the posterior communicating artery; and due to technical problems: 1. aneurysm not identified during the previous treatment, 2. aneurysm deliberately left untreated, 3. persistence of the aneurysm due to inappropriate surgery, 4. persistency of part of the aneurysm neck after clipping and 5. slipping of the clip from the neck of the aneurysm. The measures to prevent new SAH after surgery start with adequate preoperative angiographic studies, a careful inspection of the position of the clip and emptying of the aneurysm. Early angiography studies may reveal a persistent neck and later ones may reveal newly developed aneurysms. In conclusion, SAH after aneurysm clipping is a late and severe phenomenon and the concept of "cure" after this surgery should be interpreted with caution.O tratamento cirúrgico dos aneurismas cerebrais através de sua clipagem é reconhecido como eficaz e definitivo. Entretanto alguns casos sofrem nova hemorragia algum tempo após a cirurgia, deixando dúvidas sobre a "cura" pelo tratamento. Onze pacientes submetidos anteriormente a clipagem do aneurisma e que apresentaram nova hemorragia foram analisados. O intervalo de tempo da cirurgia para a nova hemorragia foi de 3 a 10 anos

  17. Combined treatment for complex intracranial aneurysm

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Complex aneurysms often cannot be completely excluded by a single approaches. Today successful treatment of these lesions requires a combination between microsurgical and endovascular techniques. Planning of combined treatment require a very good understanding of aneurysm anatomy and a close collaboration between neurosurgeon and neuroendovascular interventionist. Endovascular coiling can usually be used as early treatment for a partially aneurysm occlusion including the ruptured area and followed by definitive clipping. On the other hand microsurgical clipping also can be used as first treatment for complex aneurysm neck reconstruction, allowing successful secondary placement of coils inside the remnant aneurysm sac

  18. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Su, I. Chang [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Taipei Cathay General Hospital, Division of Neurosurgery, Department of Surgery, Taipei (China); Willinsky, Robert A.; Agid, Ronit [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Fanning, Noel F. [Cork University Hospital, Department of Interventional Neuroradiology, Cork (Ireland)

    2014-06-15

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development. We performed a retrospective analysis of consecutively treated unruptured aneurysms between January 2000 and December 2011. The presence and evolution of wall enhancement and perianeurysmal edema on MRI after endovascular treatment were analyzed. Variable factors were compared among aneurysms with and without edema. One hundred thirty-two unruptured aneurysms in 124 patients underwent endovascular treatment. Eighty-five (64.4 %) aneurysms had wall enhancement, and 9 (6.8 %) aneurysms had perianeurysmal brain edema. Wall enhancement tends to persist for years with two patterns identified. Larger aneurysms and brain-embedded aneurysms were significantly associated with wall enhancement. In all edema cases, the aneurysms were embedded within the brain and had wall enhancement. Progressive thickening of wall enhancement was significantly associated with edema. Edema can be symptomatic when in eloquent brain and stabilizes or resolves over the years. Our study demonstrates the prevalence and some appreciation of the natural history of aneurysmal wall enhancement and perianeurysmal brain edema following endovascular treatment of unruptured aneurysms. Aneurysmal wall enhancement is a common phenomenon while perianeurysmal edema is rare. These phenomena are likely related to the presence of inflammatory reaction near the aneurysmal wall. Both phenomena are usually asymptomatic and self-limited, and prophylactic treatment is not recommended. (orig.)

  19. Ortner's Syndrome: Secondary Laryngeal Paralysis Caused by a Great Thoracic Aorta Aneurysm

    Directory of Open Access Journals (Sweden)

    Zangirolami, Ana Claudia Alves

    2015-01-01

    Full Text Available Introduction Recurrent laryngeal nerve injury caused by cardiovascular disease is a rare condition, and often it is the only prominent sign of an imminent break of an aortic artery aneurysm. Objective To report left laryngeal paralysis caused by a great aortic arch aneurysm and to highlight the importance of an otorhinolaryngologic evaluation along with a thoracic radiologic study. Resumed Report A 42-year-old man complained of thickness of his voice and dysphagia for 3 months, but no thoracic pain or other relevant complaints. Video laryngoscopy revealed immobility of his left vocal fold in the paramedian position. Imaging was obtained for investigation, including magnetic resonance imaging of his thorax, which showed a fusiform aneurysm in the aortic arch, leading to recurrent compression of the left laryngeal nerve. The patient was successfully treated with endovascular repair of the aneurysm. At 2-month follow-up, there was still no recovery of the laryngeal mobility. Conclusion An aortic artery aneurysm can suddenly break, requiring emergency heart surgery, and the results can be fatal in many cases. We suggest routine exam of the vocal folds in all patients with a heart condition, and we review the literature and suggest the use of imaging to reduce the number of emergency procedures.

  20. Bladder exstrophy repair

    Science.gov (United States)

    Bladder birth defect repair; Everted bladder repair; Exposed bladder repair; Repair of bladder exstrophy ... Bladder exstrophy repair involves two surgeries. The first surgery is to repair the bladder and the second one is to attach ...

  1. Off-pump anteroapical aneurysm plication for left ventricular post-infarction aneurysm: long-term results

    Institute of Scientific and Technical Information of China (English)

    HUANG Xin-sheng; ZHOU Qi-wen; GU Cheng-xiong; YANG Jun-feng; WEI Hua; LI Jing-xing; YU Yang; FANG Ying; LIU Rui; LI Hai-tao

    2012-01-01

    Background The temporal response to off-pump anteroapical aneurysm plication has not been well defined.We have evaluated the long-term clinical and functional results of this technique and compared the efficacy with the patch modeling repair.Methods From March 2005 to May 2010,163 (115 men and 48 women) consecutive patients were operated on for post-infarction left ventricular aneurysm (LVA),54 patients underwent patch remodeling (group A) and 109 patients underwent off-pump anteroapical aneurysm plication repair (group B).All patients had simultaneous coronary revascularization,other operative procedures included septoplasty in eight and ablation of ventricular tachycardia in six.Follow-up ranged from 1 to 5 years,short-term and mid-term outcomes,including complications,cardiac function,and mortality,were assessed.Results Early mortality was 1.8% for all patients (group A 1 death vs.group B 2 deaths,not significant (NS)).Peri-operative support included intraaortic balloon pumping in 16 (9.8%),(group A 6 patients vs.group B 10 patients,NS)and inotropic drugs in 84 (51.5%),(group A 34 vs.group B 50,NS).During a mean follow-up of (3.7±0.8) years,eight patients died,with four due to cardiac-related causes.No patient required transplantation,and two required use of an implantable cardioverter-defibrillator for ventricular tachycardia.Survival at 1 and 5 years was 95% and 86%,respectively.It did not differ significantly between group A and group B.Functional class improved from 2.90±0.59 to 1.65±0.54 among the mid-term survivors (P <0.001),with no significant difference between the two groups.Pre-operative risk factors for mortality or poor function were ejection fraction (EF) <0.35 (OR=7.9,95% CI 1.6-40.0); congestive heart failure (CHF) (OR=4.4,95% CI 1.0-19.0); end-systolic volume index (ESVI) >80 ml/m2 (OR=3.7,95% C/ 1.0-14.0); and advanced age >70 years (OR=2.4,95% C/ 1.0-12.0).Conclusions The technique of off-pump anteroapical aneurysm

  2. Surgical management of a hypoplastic distal aortic arch and coarctation of aorta in a patient with Klippel-Feil syndrome, ascending aortic aneurysm and bicuspid aortic valve.

    Science.gov (United States)

    Sabol, Frantisek; Kolesar, Adrián; Toporcer, Tomás; Bajmoczi, Milan

    2014-10-01

    Klippel-Feil syndrome has been associated with cardiovascular malformations, but only 3 cases have been reported to be associated with aortic coarctation and surgical management is not defined. A 51-year old woman with Klippel-Feil syndrome associated with an aneurysm of the ascending aorta, hypoplastic aortic arch and aortic coarctation at the level of the left subclavian artery presented with shortness of breath 2 years after diagnosis. Imaging identified interim development of a 7.2-cm aneurysm at the level of the aortic coarctation. She underwent surgical repair with a Dacron interposition graft under hypothermic circulatory arrest. She continues to do well 18 months following repair.

  3. The Potential Role of Kallistatin in the Development of Abdominal Aortic Aneurysm

    OpenAIRE

    Jiaze Li; Smriti Murali Krishna; Jonathan Golledge

    2016-01-01

    Abdominal aortic aneurysm (AAA) is a vascular condition that causes permanent dilation of the abdominal aorta, which can lead to death due to aortic rupture. The only treatment for AAA is surgical repair, and there is no current drug treatment for AAA. Aortic inflammation, vascular smooth muscle cell apoptosis, angiogenesis, oxidative stress and vascular remodeling are implicated in AAA pathogenesis. Kallistatin is a serine proteinase inhibitor, which has been shown to have a variety of funct...

  4. Rebleeding of a Splenic Artery Aneurysm after Coil Embolisation

    Directory of Open Access Journals (Sweden)

    Kyra D. Kingma

    2016-01-01

    Full Text Available Background. Splenic artery aneurysm (SAA is an uncommon and difficult diagnosis. SAA is more common in females. Only 20% of SAA is symptomatic and may present as a rupture. A ruptured SAA is associated with a 25% mortality rate. Case Presentation. We present a case of a male patient with a bleeding SAA that rapidly increased in size. Distal coiling was technically impossible and despite proximal coil embolisation the SAA continued to bleed. A laparotomy including splenectomy and partial pancreatectomy was performed with an uneventful patient recovery. Discussion. Endovascular management is currently considered the optimal treatment of SAA. However, careful monitoring and follow-up is needed after embolisation as rapid recanalization of the SAA may possibly occur, especially when distal coiling of the aneurysm is unsuccessful. Conclusion. Endovascular treatment of an SAA is not necessarily effective. Surgeons must be prepared to perform open procedures to further reduce mortality rates.

  5. Aortic aneurysm surgery: problems and innovations Cirurgia do aneurisma aórtico: problemas e inovações

    Directory of Open Access Journals (Sweden)

    Ralf Kolvenbach

    2009-12-01

    Full Text Available A long way was traveled since the first surgery was performed for the treatment of abdominal aortic aneurysm. Throughout this time, several innovations have been created in order to reduce the invasiveness of the surgical procedures and to improve their safety and durability. This review discusses the major and recent advances on aortic aneurysm interventions, including, the endovascular aortic repair, the laparoscopic aortic surgery, the conventional hybrid and endovascular techniques, combined laparoscopic and endovascular techniques, as well as future prospects for both thoracic and abdominal aorta. Faced with so many changes and developments, modern vascular surgeons must keep their minds open to innovations and should develop comprehensive training with different techniques, to provide the best therapeutic option for their patients.Um longo caminho foi percorrido desde as primeiras intervenções cirúrgicas feitas para o tratamento do aneurisma de aorta abdominal. Ao longo deste tempo, várias inovações foram criadas, no sentido de reduzir a invasividade dos procedimentos e melhorar sua segurança e durabilidade. Nesta revisão, são discutidos os principais e recentes avanços em intervenções sobre aneurismas aórticos, incluindo a restauração aórtica endovascular, a cirurgia aórtica videolaparoscópica, as técnicas híbridas convencionais e endovasculares, as técnicas combinadas videolaparoscópicas e endovasculares, bem como as perspectivas futuras, tanto para aorta torácica como abdominal. Diante de tantas transformações e evolução, o cirurgião vascular moderno terá que ter sua mente aberta para as novidades e desenvolver capacitação ampla com diferentes técnicas para proporcionar a melhor opção terapêutica para seus pacientes.

  6. Endovascular Exclusion of an Abdominal Aortic Aneurysm in Patients with Concomitant Abdominal Malignancy: Early Experience

    Energy Technology Data Exchange (ETDEWEB)

    Choi, You Ri; Chang, Nam Kyu [Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Hyo Hyun; Oh, Hyun Jun; Kim, Jae Kyu; Choi, Soo Jin Na; Chung, Sang Young [Chonnam National University Hospital, Gwangju (Korea, Republic of); Yim, Nam Yeol [Armed Forces Yangju Hospital, Yangju (Korea, Republic of)

    2010-08-15

    To assess the outcomes of endovascular aortic aneurysm repair (EVAR) for the treatment of an abdominal aortic aneurysm in patients undergoing curative surgical treatment for concomitant abdominal malignancy. The study included 12 patients with abdominal neoplasia and an abdominal aortic aneurysm (AAA), which was treated by surgery and stent EVAR. The neoplasm consisted of the gastric, colorectal, pancreas, prostate, and gall bladder. The follow up period was 3-21 months (mean 11.8 months). All medical records and imaging analyses were reviewed by CTA and/or color Doppler US, retrospectively. Successful endoluminal repair was accomplished in all twelve patients. The mean interval time between EVAR and surgery was 58.6 days. Small amounts of type 2 endoleaks were detected in two patients (17%). One patient developed adult respiratory distress syndrome after Whipple's operation 20 days after surgery, which led to hopeless discharge. No procedure-related mortality, morbidity, or graft-related infection was noted. Exclusion of AAA in patients with accompanying malignancy show with a relatively low procedure morbidity and mortality. Hence, endoluminal AAA repair in patients with synchronous neoplasia may allow greater flexibility in the management of an offending malignancy

  7. Hérnias incisionais no pós-operatório de correção de aneurisma de aorta abdominal Postoperative incisional hernias after open abdominal aortic aneurysm repair

    OpenAIRE

    2012-01-01

    CONTEXTO: A incidência de hérnia incisional no pós-operatório da correção aberta de aneurisma de aorta abdominal é alta, variando de 10 a 37% e mais de três vezes mais comum do que em pacientes submetidos à correção para doença obstrutiva aorto-ilíaca. OBJETIVO: Apresentar a incidência de hérnia incisional em um grupo de pacientes acompanhados no pós-operatório da correção aberta de aneurisma de aorta abdominal. MÉTODOS: Série de casos em uma população de 144 pacientes operados por aneurisma ...

  8. Oculomotor Paresis and Basilar Aneurysm

    OpenAIRE

    J Gordon Millichap

    1992-01-01

    The clinical and pathologic findings in a 10 month old girl with congenital heart diseasewho died after rupture of a congenital distal basilar artery aneurysm are reported from the University of Connecticut Health Center, Farmington, CT and the Children’s Hospital of Philadelphia, PA.

  9. [The treatment of abdominal aortic aneurysms by use of endovascular prosthesis and classic vascular prosthesis].

    Science.gov (United States)

    Pupka, Artur; Szyber, Przemysław P; Janczak, Dariusz; Pawłowski, Stanisław; Szyber, Piotr

    2006-01-01

    The abdominal aortic aneurysm is a dilatation of infrarenal part of aorta. Its ethiology is still unknown. An infection and congenital disorders of conjunctive tissue are regarded as the main risc factors. Other factors could be a perimural thrombus and elastin and colagen degradation. It's not proved that atheromatosis is a risc factor. The disease concerns mainly the old males. Not treated aneurysm grows until rupture. The aneurysms are usually asympthomatic. Majority of them are found incidentally. Ultrasonography and computed tomography are used to extended diagnosis. The open surgery or endovascular surgery are only possible ways of treatment. The aneurysm with diameter over 55 milimeters, sympthomatic or rupted is an indication for surgery. The aim of the open surgery is implantation of the vascular prosthesis into retroperitoneal space. Endovascular method consist in placement of stent-graft in the lumen of aneurysm through small incision in a peripherial vessel. Stent-graft consists of metal chassis covered by classic vascular prosthesis. This method still requires the long-term assessment.

  10. Aneurysm occlusion in elderly patients with aneurysmal subarachnoid hemorrhage : a cost-utility analysis

    NARCIS (Netherlands)

    Koffijberg, H.; Rinkel, G.J.; Buskens, E.

    2011-01-01

    BACKGROUND: Aneurysm occlusion after subarachnoid hemorrhage (SAH) aims to improve outcome by reducing the rebleeding risk. With increasing age overall prognosis decreases and the complications of aneurysm occlusion increase. The balance of risks for aneurysm occlusion in elderly SAH patients in dif

  11. Aneurysm occlusion in elderly patients with aneurysmal subarachnoid haemorrhage : a cost-utility analysis

    NARCIS (Netherlands)

    Koffijberg, H.; Buskens, E.; Rinkel, G. J. E.

    2011-01-01

    Background Aneurysm occlusion after subarachnoid haemorrhage (SAH) aims to improve outcome by reducing the rebleeding risk. With increasing age, overall prognosis decreases, and the complications of aneurysm occlusion increase. The balance of risks for aneurysm occlusion in elderly SAH patients in d

  12. Comparative study of laparoscopic transabdominal preperitoneal hernia repair and open preperitoneal hernia repair for inguinal hernia%腹腔镜经腹腹膜前疝修补术与开腹腹膜前疝修补术治疗腹股沟疝的对比研究

    Institute of Scientific and Technical Information of China (English)

    林洋; 穆林松; 隋武; 于文涛

    2015-01-01

    目的:探讨经腹腹膜前腹腔镜腹股沟疝修补术与开腹腹膜前疝修补术治疗腹股沟疝的优势。方法回顾性分析2012年1月至2013年1月,青岛大学医学院附属烟台毓璜顶医院收治的72例腹股沟疝手术患者的临床资料。其中试验组38例,行腹腔镜腹股沟疝修补术;对照组34例,行开腹腹膜前疝修补术。结果本组手术均顺利完成,二组间术中出血量、术后下床活动时间、术后住院时间差异无统计学意义;手术时间、肛门排气时间差别无统计学意义;二组尿潴留、伤口感染、血肿、血清肿、伤口疼痛、术后复发差别无统计学意义。结论经腹腹膜前腹腔镜腹股沟疝修补术及开腹腹膜前疝修补术都是安全有效的,各有其优点,术者应该根据患者病情合理地选择术式。%Objective To explore the difference between laparoscopic transabdominal preperitoneal hernia repair (TAPP) and open preperitoneal hernia repair for the treatment of inguinal hernia. Methods A total of 72 cases with inguinal hernia underwent hernia repair in Yantai Yu Huang Ding Hospital affiliated to Qingdao University School of Medicine from January 2012 to January 2013 were retrospectively analyzed. 38 cases in test group were applied with TAPP, and 34 cases in control group with open preperitoneal hernia repair. Results All operations were successfully completed. No significant difference was found in blood loss during operation, postoperative activity time, and postoperative hospitalization time. There was no statistically significant difference in operation time and pass flatus time between these two groups. There was no statistically significant difference in urinary retention, wound infection, hematoma, seroma, wound pain and recurrence. Conclusion Both TAPP hernia repair and open preperitoneal hernia repair are safe and effective methods for the treatment of inguinal hernia. Either of way has its advantages

  13. 探讨腹腔镜下穿孔修补术和开腹修补术治疗胃十二指肠溃疡穿孔的临床效果%Study on Clinical Effect of Laparoscopic Perforation Repair Surgery and Open Repair Surgery in Treatment of Gastric Ulcer Perforation

    Institute of Scientific and Technical Information of China (English)

    刘敬炳

    2016-01-01

    目的:对腹腔镜下穿孔修补术和开腹修补术治疗胃十二指肠溃疡急性穿孔的临床效果进行探讨。方法整群选取该院2013年1月—2015年10月收治的76例胃十二指肠溃疡急性穿孔患者,分为观察组和对照组,观察组患者接受腹腔镜修补术的治疗,对照组患者接受开腹修补术的治疗,对比临床效果。结果观察组患者住院时间、术后切口感染率等指标均显著优于对照组患者,差异有统计学意义(P<0.05);观察组、对照组复发率分别为8.9%、10.53%,观察组并发症发生率分别为2.63%、28.95%,两组复发率差异无统计学意义,并发症发生率差异有统计学意义(P<0.05)。结论相较于开腹修补术,腹腔镜下修补术具有住院时间短、切口感染率低等优点,可有效降低患者并发症发生率。%Objective To study the clinical effect of laparoscopic perforation repair surgery and open repair surgery in treatment of gastric ulcer perforation. Methods 76 cases of patients with gastric ulcer perforation admitted and treated in our hospital from January 2013 to October 2015 were selected and divided into two groups, the observation group were treated with laparoscopic repair surgery, the control group were treated with open repair surgery, and the clinical effects were compared. Results The indexes including length of stay and postoperative incision infection rate in the observation group were obviously better than those in the control group and the differences were obvious, P<0.05, and there was an ob-vious difference in the recurrence rate between the observation group and the control group, (8.9% vs 10.53%), and there was an obvious difference in the incidence rate of complications between the observation group and the control group, (2.63% vs 28.95%), P<0.05. Conclusion Compared with the open repair surgery, the laparoscopic repair surgery has the advantages of short length of stay and low incision

  14. Isolated iliac artery aneurysms with associated hydronephrosis.

    LENUS (Irish Health Repository)

    O'Driscoll, D

    2012-02-03

    An isolated iliac artery aneurysm is where there is aneurysmal dilatation of one or more branches of the iliac system, with no associated dilatation of the aorta. Such aneurysms are rare and comprise 1% of all intra-abdominal aneurysms. The signs and symptoms of such an aneurysm are influenced by its concealed location within the bony pelvis. Awareness of these special characteristics improves the chances of early diagnosis and proper treatment before possible rupture. We present the clinical and radiological features of three such aneurysms. Ultrasound was the first imaging modality to be performed. Ipsilateral hydronephrosis was demonstrated in each case, this lead to imaging the pelvis and the correct diagnosis. We review the clinical and radiological literature and conclude that the pelvis should be imaged in all cases of unexplained hydronephrosis.

  15. Meta-analysis of laparoscopic and open repair of perforated peptic ulcer%腹腔镜与开腹消化性溃疡穿孔修补术比较的Meta分析

    Institute of Scientific and Technical Information of China (English)

    丁杰; 王少勇; 廖国庆; 张忠民; 潘扬; 李东苗; 王润华; 徐开盛; 杨晓飞; 袁平

    2011-01-01

    目的 评价腹腔镜修补手术治疗消化性溃疡穿孔的安全性和有效性.方法 收集1990-2011年公开发表的腹腔镜和开腹消化性溃疡穿孔修补术的中文和英文文献,对腹腔镜组和开腹组的术中情况、术后恢复情况及术后并发症情况进行Meta分析.结果 筛选出符合纳入标准的研究19项,共1507例,腹腔镜组673例,开腹组834例.与开腹组相比,腹腔镜组患者术中出血量更少,术后排气时间更快、住院时间更短、术后切口感染率和围手术期死亡率更低(均P<0.05).两组患者手术时间和术后败血症、肺部感染、腹腔脓肿、修补处瘘发生率的差异则无统计学意义(均P>0.05).结论 腹腔镜修补手术治疗消化性溃疡穿孔具有出血少、恢复快、切口感染和死亡率低的优势,安全可行.%Objective To assess the safety and feasibility of laparoscopic and open repair of perforated peptic ulcer.Methods Studies on comparison between laparoscopic repair (LR) and open repair (OR) of perforated peptic ulcer were collected.Data of operating time,blood loss,time to first flatus,postoperative hospital stay,postoperative complications and mortality between LR group and OR group were meta-analyzed using fixed effect model and random effect model.Results Nineteen studies including 1507 patients were selected for this study,including laparoscopic surgery (n=673)and open surgery (n=834).There were significant differences in blood loss,time to first flatus,postoperative hospital stay,wound infection rate and mortality between LR group and OR group.However,no significant differences existed in operative time,postoperative sepsis,pulmonary infection,abdominal abscess,and suture leakage between the two groups.Contusions Laparoscopic repair of perforated peptic ulcer is associated with improved outcomes in terms of less blood loss,quicker recovery,and lower rates of wound infection and mortality.Laparoscopic repair of perforated peptic

  16. Management of splenic artery aneurysm associatedwithextrahepaticportal veinobstruction

    Institute of Scientific and Technical Information of China (English)

    Pramod Kumar Mishra; Sundeep Singh Saluja; Ashok K Sharma; Premanand Pattnaik

    2012-01-01

    BACKGROUND: Splenic artery aneurysms although rare are clinically signiifcant in view of their propensity for spontaneous rupture and life-threatening bleeding. While portal hypertension is an important etiological factor, the majority of reported cases are secondary to cirrhosis of the liver. We report three cases of splenic artery aneurysms associated with extrahepatic portal vein obstruction and discuss their management. METHODS: The records of three patients of splenic artery aneurysm associated with extrahepatic portal vein obstruction managed from 2003 to 2010 were reviewed retrospectively. The clinical presentation, surgical treatment and outcome were analyzed. RESULTS:  The aneurysm was >3 cm in all patients. The clinical symptoms were secondary to extrahepatic portal vein obstruction (hematemesis in two, portal biliopathy in two) while the aneurysm was asymptomatic. Doppler ultrasound demonstrated aneurysms in all patients. A proximal splenorenal shunt was performed in two patients with excision of the aneurysm in one patient and ligation of the aneurysm in another one. The third patient had the splenic vein replaced by collaterals and hence underwent splenectomy with aneurysmectomy. All patients had an uneventful post-operative course. CONCLUSIONS: Splenic artery aneurysms are associated with extrahepatic portal vein obstruction. Surgery is the mainstay of treatment. Although technically dififcult, it can be safely performed in an experienced center with minimal morbidity and good outcome.

  17. Pathomechanisms and treatment of pediatric aneurysms.

    Science.gov (United States)

    Krings, Timo; Geibprasert, Sasikhan; terBrugge, Karel G

    2010-10-01

    Pediatric aneurysms are rare diseases distinct from classical adult aneurysms and therefore require different treatment strategies. Apart from saccular aneurysms that are more commonly found in older children, three major pathomechanisms may be encountered: trauma, infection, and dissection. The posterior circulation and more distal locations are more commonly encountered in children compared to adults, and there is an overall male predominance. Clinical findings are not only confined to subarachnoid hemorrhage but may also comprise mass effects, headaches or neurological deficits. In traumatic aneurysms, the skull base and distal anterior communicating artery are commonly affected, and the hemorrhage occurs often delayed (2-4 weeks following the initial trauma). Infectious aneurysms are mostly bacterial in origin, and hemorrhage occurs early after a septic embolic shower. Dissecting aneurysms are the most often encountered aneurysm type in children and can lead to mass effect, hemorrhage, or ischemia depending on the fate of the intramural hematoma. Treatment strategies in pediatric aneurysms include endosaccular coil treatment only for the "classical berry-type" aneurysms; in the other instances, parent vessel occlusion, flow reversal, surgical options, or a combined treatment with bypass and parent vessel occlusion have to be contemplated.

  18. Mycotic Aneurysm of the Aortic Arch

    Directory of Open Access Journals (Sweden)

    Ji Hye Seo

    2014-08-01

    Full Text Available A mycotic aneurysm of the thoracic aorta is rare. We report a case of mycotic aneurysm that developed in the aortic arch. An 86-year-old man was admitted with fever and general weakness. Blood culture yielded methicillin-resistant Staphylococcus aureus. Chest X-ray showed an enlarged aortic arch, and computed tomography scan revealed an aneurysm in the aortic arch. The patient was treated only with antibiotics and not surgically. The size of the aneurysm increased rapidly, resulting in bronchial obstruction and superimposed pneumonia. The patient died of respiratory failure.

  19. Endovascular treatment for pediatric intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xianli; Jiang, Chuhan; Li, Youxiang; Yang, Xinjian; Wu, Zhongxue [Capital Medical University, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Beijing, Hebei (China)

    2009-11-15

    The purpose of this study is to report the characteristics and outcomes of pediatric patients with intracranial aneurysms. From 1998 to 2005, 25 pediatric patients (aged {<=}17 years) with intracranial aneurysm were treated at our institute. Eleven of 25 patients had subarachnoid hemorrhage. In ten patients, the aneurysm was an incidental finding. One patient presented with cranial nerves dysfunction and three with neurological deficits. The locations of the aneurysms were as follows: vertebral artery (VA; n = 9), middle cerebral artery (MCA; n = 5), posterior cerebral artery (PCA; n = 4), basilar artery (BA; n = 2), anterior communicating artery (n = 2), anterior cerebral artery (n = 2), and internal carotid artery (n = 1). Five patients were treated with selective embolization with coils. Sixteen patients were treated with parent vessel occlusion (PVO). Eight PVOs were performed with balloons and eight were performed with coils. One patient with a VA aneurysm was spontaneously thrombosed 4 days after the initial diagnostic angiogram. In three patients treated with stent alone or stent-assisted coiling, one with BA trunk aneurysm died. One aneurismal recurrence occurred and was retreated. At a mean follow-up duration of 23.5 months, 96% of patients had a Glasgow Outcome Scale score of 4 or 5. Pediatric intracranial aneurysms occur more commonly in male patients and have a predilection for the VA, PCA, and MCA. PVO is an effective and safe treatment for fusiform aneurysms. Basilar trunk fusiform aneurysms were difficult to treat and were associated with a high mortality rate. (orig.)

  20. Endovascular management of visceral artery aneurysms: When to watch, when to intervene?

    Institute of Scientific and Technical Information of China (English)

    Romaric; Loffroy; Sylvain; Favelier; Pierre; Pottecher; Pierre-Yves; Genson; Louis; Estivalet; Sophie; Gehin; Jean-Pierre; Cercueil; Denis; Krausé

    2015-01-01

    Visceral artery aneurysms(VAA) include splanchnic and renal artery aneurysms. They represent a rare clinical entity, although their detection is rising due to an increased use of cross-sectional imaging. Rupture is the most devastating complication, and is associated with a high morbidity and mortality. In addition, increased percutaneous endovascular interventions have raised the incidence of iatrogenic visceral artery pseudoaneurysms(VAPAs). For this reason, elective repair is preferable in the appropriately chosen patient. Controversy still exists regarding their treatment. Over the past decade, there has been steady increase in the utilization of minimally invasive, non-operative interventions, for vascular aneurysmal disease. All VAAs and VAPAs can technically be fixed by endovascular techniques but that does not mean they should. These catheter-based techniques constitute an excellent approach in the elective setting. However, in the emergent setting it may carry a higher morbidity and mortality. The decision for intervention has to take into account the size and the natural history of the lesion, the risk of rupture, which is high during pregnancy, and the relative risk of surgical or radiological intervention. For splanchnic artery aneurysms, we should recognize that we are not, in reality, well informed about their natural history. For most asymptomatic aneurysms, expectant treatment is acceptable. For large, symptomatic or aneurysms with a high risk of rupture, endovascular treatment has become the firstline therapy. Treatment of VAPAs is always mandatory because of the high risk of rupture. We present our point of view on interventional radiology in the splanchnic arteries, focusing on what has been achieved and the remaining challenges.

  1. Treatment of complex intracranial aneurysms using flow-diverting silk® stents. An analysis of 32 consecutive patients.

    Science.gov (United States)

    Buyukkaya, Ramazan; Kocaeli, Hasan; Yildirim, Nalan; Cebeci, Hakan; Erdogan, Cüneyt; Hakyemez, Bahattin

    2014-12-01

    This study describes the peri-procedural and late complications and angiographic follow-up results of 32 patients with 34 complex aneurysms treated with flow diverter Silk stents in a single centre. In this retrospective study, 40 Silk stents (SS) were implanted in 34 complex intracranial aneurysms in 32 patients. In our series, 20 (58.8%) carotid-ophthalmic internal carotid artery (ICA), six (17.6%) cavernous ICA, two (5.9%) supraclinoid ICA, two (5.9%) petrosal ICA (the same patient- bilateral) and four (11.8%) posterior circulation aneurysms were treated. One of the posterior circulation lesions was a fenestrated-type aneurysm. Twenty wide-necked, saccular; eight neck remnant; four fusiform and two blister-like aneurysms were included in our series. SS were successfully implanted in all patients (100%). Misdeployment occurred in 17.6% of patients. In two of these patients adequate stent openness was achieved via Hyperglide balloon dilatation. Coil embolization in addition to SS placement was utilized in four aneurysms. One patient (3%) experienced transient morbidity due to a thromboembolic event and there was one mortality (3%) due to remote intraparenchymal haemorrhage. Complete occlusion of 27/33 (81.8 %) and 29/33 (87.9 %) aneurysms was achieved six and 12 months after the procedure, respectively. In-stent intimal hyperplasia was detected in 6.1 % patients. Flow-diverter Silk stent implantation is an effective method of treating complex aneurysms with acceptable mortality and morbidity rates. Complete occlusion is achieved in most of the complex aneurysms.

  2. Pulmonary artery aneurysm with patent arterial duct: resection of aneurysm and ductal division.

    Science.gov (United States)

    Tefera, Endale; Teodori, Michael

    2013-10-01

    Congenital or acquired aneurysm of the pulmonary artery (PA) is rare. Although aneurysms are described following surgical treatment of patent ductus arteriosus (PDA), occurrence of this lesion in association with PDA without previous surgery is extremely uncommon. An eight-year-old patient with PDA and aneurysm of the main PA is described in this report. Clinical diagnosis of PDA was made upon presentation. Diagnosis of PA aneurysm was suspected on chest x-ray and was confirmed on transthoracic echocardiography. Successful surgical resection of the aneurysm and division of the duct were performed under cardiopulmonary bypass. The patient did well on follow-up both from clinical and echocardiographic point of view.

  3. [A case of successful treatment of concomitant ruptured intracranial aneurysm and visceral aneurysm].

    Science.gov (United States)

    Diogo, Cláudia; Baltazar, José; Fernandes, Mário

    2012-01-01

    The association between intracranial and visceral aneurysms is very rare, with a bad prognosis. The rupture usually appears in the Emergency Room, and it implies an immediate treatment. We describe the case of a woman with rupture of an anterior communicant artery aneurysm and rupture of a pancreatic duodenal artery aneurysm. The actuation of all specialties allowed the direct surgical treatment of the visceral aneurysm, without the aggravation of the cerebral hemorrhage that the eventual Aorta Artery clamping could provoke. The maintenance of the hemodynamic stability was essential for the posterior treatment of the intracranial aneurysm.

  4. Neurophysiological characterization of persistent pain after laparoscopic inguinal hernia repair

    DEFF Research Database (Denmark)

    Linderoth, G; Kehlet, H; Aasvang, E K;

    2011-01-01

    About 2-5% of patients undergoing laparoscopic inguinal repair experience persistent pain influencing everyday activities. However, compared with persistent pain after open repair, the combined clinical and neurophysiological characteristics have not been described in detail. Thus, the aim...

  5. Low-profile Visualized Intraluminal Support Junior Device for the Treatment of Intracranial Aneurysms

    Science.gov (United States)

    Gupta, Mihir; Cheung, Vincent J; Abraham, Peter; Wali, Arvin R; Gabel, Brandon C; Almansouri, Abdulrahman; Pannell, J. Scott; Khalessi, Alexander A

    2017-01-01

    Objective: Early case series suggest that the recently introduced Low-profile Visualized Intraluminal Support Junior (LVIS Jr.) device (MicroVention-Terumo, Inc., Tustin, CA) may be used to treat wide-necked aneurysms that would otherwise require treatment with intrasaccular devices or open surgery. We report our single-center experience utilizing LVIS Jr. to treat intracranial aneurysms involving 1.8-2.5 mm parent arteries. Methods: We retrospectively reviewed records of patients treated with the LVIS Jr. device for intracranial aneurysms at a single center. A total of 21 aneurysms were treated in 18 patients. Aneurysms were 2-25 mm in diameter; one was ruptured, while three had recurred after previous rupture and treatment. Lesions were distributed across the anterior (n=12) and posterior (n=9) circulations. Three were fusiform morphology. Results: Stent deployment was successful in 100% of cases with no immediate complications. Seventeen aneurysms were treated with stent-assisted coil embolization resulting in immediate complete occlusion in 94% of cases. Two fusiform aneurysms arising from the posterior circulation were further treated with elective clip ligation after delayed expansion and recurrence; no lesions required further endovascular treatment. Four aneurysms were treated by flow diversion with stand-alone LVIS Jr. stent, and complete occlusion was achieved in three cases. Small foci of delayed ischemic injury were noted in two patients in the setting of antiplatelet medication noncompliance. No in-stent stenosis, migration, hemorrhage, or permanent deficits were observed. Good functional outcome based on the modified Rankin Scale score (mRS ≤ 2) was achieved in 100% of cases. Conclusion: Our midterm results suggest that the LVIS Jr. stent may be used for a variety of intracranial aneurysms involving small parent arteries (1.8-2.5 mm) with complete angiographic occlusion, parent vessel preservation, and functional clinical outcomes. This off

  6. Cobbler's technique for Iridodialysis repair

    Directory of Open Access Journals (Sweden)

    Surinder Singh Pandav

    2016-01-01

    Full Text Available We describe a novel “Cobbler's technique” for iridodialysis repair in the right eye of a patient aged 18 years, with a traumatic iridodialysis secondary to open globe injury with an iron rod. Our technique is simple with easy surgical maneuvers, that is, effective for repairing iridodialysis. The “Cobbler's technique” allows a maximally functional and cosmetic result for iridodialysis.

  7. 腹腔镜与开腹修补消化性溃疡穿孔的临床比较分析%Comparative analysis of laparoscopic and open repair of peptic ulcer perforation clinical

    Institute of Scientific and Technical Information of China (English)

    陈燕青; 葛建国

    2014-01-01

    Objective To compare the clinical effect of open and laparoscopic repair in the treatment of peptic ulcer perforation. Methods 56 cases of peptic ulcer perforation were randomly divided into two groups,28 cases in each group. The control group used open neoplasty,research group usedlaparoscopic repair,comparative analysis of two groups of patients with clinical efficacy. Results The study group patients operative bleeding and postoperative pain score,the exhaust time,hospitalization time and other indicators were significantly lower than the control group,and the incidence of complications is significantly less than the control group,the difference between the two significant,with statistical significance,P<0.05. Conclusion Using laparoscopic repair can effectively reduce operation wound,relieve pain,patients,and has application value and popularization value in clinical practice.%目的:探讨并对比分析开腹与腹腔镜修补术治疗消化性溃疡穿孔的临床效果。方法将56例消化性溃疡穿孔患者随机分为两组,每组28例。对照组采用开腹修补术,研究组采用腹腔镜修补术,对比分析两组患者临床情况和效果。结果研究组患者手术中出血量以及术后疼痛评分、排气时间、住院时间等指标均明显比对照组低,且并发症发生率也明显比对照组少,二者差异具有统计学意义(P<0.05)。结论在消化性溃疡穿孔的临床治疗中,采用腹腔镜修补术可有效减轻手术创伤,缓解疼痛,便于患者的康复,在临床中具有应用和推广价值。

  8. Spontaneous regression of intracranial aneurysm following remote ruptured aneurysm treatment with pipeline stent assisted coiling.

    Science.gov (United States)

    Tsimpas, Asterios; Ashley, William W; Germanwala, Anand V

    2016-10-01

    Spontaneous aneurysm regression is a rare phenomenon. We present the interesting case of a 54-year-old woman who was admitted with a Hunt/Hess grade IV, Fisher grade III subarachnoid hemorrhage and multiple intracranial aneurysms. She was treated with coiling of the largest paraclinoid aneurysm and placement of a flow diverting pipeline embolization device that covered all internal carotid artery (ICA) aneurysms. A follow-up angiogram at 6 months showed remodeling of the ICA with complete obliteration of all treated aneurysms. A distant, untreated, right frontal M2 aneurysm regressed spontaneously, after the flow was diverted away from it with the stent. The literature is reviewed, and potential pathophysiological mechanisms leading to aneurysm regression are discussed.

  9. Aneurismas poplíteos: estudo retrospectivo Popliteal Aneurysms: retrospective study

    Directory of Open Access Journals (Sweden)

    Ana Baptista

    2010-12-01

    January 1st 2004 and December 31st 2008 were reviewed. Results: From a total of 61 patients, 37 (60,7% had bilateral aneurysms. Of those 61 patients, 58 were males and 3 were females. The mean age was 66,9 ± 11,6 years. 36,1% of the patients had also aneurysms in other locations. The majority of the aneurysms were asymptomatic. When symptomatic, the most frequent presentation was acute ischemia caused by thrombosis of the aneurysm. Of all the popliteal aneurysms (n=98, 37 were repaired electively, 29 urgently and 32 were not repaired. The most used surgical interventions were the exclusion of the aneurysm by distal femoropopliteal bypass with greater saphenous vein (n=48 or with prosthesis (n=16. Primary patency rates at 30 days were of 98% with vein and of 68,8% with prosthesis, which caused 3 transfemoral amputations. Conclusions: Popliteal aneurysms are more prevalent in males, frequently bilateral and there is a strong connection between them and aneurysms in other locations/arteriomegaly. The ideal surgical treatment is the elective repair with autologous material, being the patency rates with prosthesis inferior to the ones with vein.

  10. Idiopathic giant right atrial aneurysm

    Directory of Open Access Journals (Sweden)

    Santosh C Uppu

    2013-01-01

    Full Text Available A 2-year-old boy with an incidental finding of massive cardiomegaly on a chest X-ray was diagnosed with a giant right atrial aneurysm upon further investigation with echocardiography. The patient underwent successful surgical reduction of the right atrium and closure of the patent foramen ovale to prevent thromboembolic complications and to lower the risk of atrial arrhythmias. The resected atrium had paper-thin walls and pathological features of interstitial fibrosis with endocardial thickening.

  11. Endovascular treatment of popliteal artery aneurysm. Early and midterm results

    Directory of Open Access Journals (Sweden)

    Rodrigo Borges Domingues

    2015-02-01

    Full Text Available OBJECTIVE: to evaluate the efficacy of endovascular repair of popliteal artery aneurysms on maintaining patency of the stent in the short and medium term. METHODS: this was a retrospective, descriptive and analytical study, conducted at the Integrated Vascular Surgery Service at the Hospital da Beneficência Portuguesa de São Paulo. We followed-up 15 patients with popliteal aneurysm, totaling 18 limbs, treated with stent from May 2008 to December 2012. RESULTS: the mean follow-up was 14.8 months. During this period, 61.1% of the stents were patent. The average aneurysm diameter was 2.5cm, ranging from 1.1 to 4.5cm. The average length was 5cm, ranging from 1.5 to 10 cm. In eight cases (47.1%, the lesion crossed the joint line, and in four of these occlusion of the prosthesis occurred. In 66.7% of cases, treatment was elective and only 33.3% were symptomatic patients treated on an emergency basis. The stents used were Viabahn (Gore in 12 cases (66.7%, Fluency (Bard in three cases (16.7%, Multilayer (Cardiatis in two cases (11.1% and Hemobahn (Gore in one case (5.6%. In three cases, there was early occlusion (16.6%. During follow-up, 88.2% of patients maintained antiplatelet therapy. There was no leakage at ultrasound (endoleak. No fracture was observed in the stents. CONCLUSION: the results of this study are similar to other published series. Probably, with the development of new devices that support the mechanical characteristics found on the thighs, there will be improved performance and prognosis of endovascular restoration.

  12. Shared Genetic Risk Factors of Intracranial, Abdominal, and Thoracic Aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    BACKGROUND: Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. METHODS AND RE

  13. Familial Abdominal Aortic Aneurysm : Clinical Features and Genetics

    NARCIS (Netherlands)

    K.M. van de Luijtgaarden (Koen)

    2016-01-01

    markdownabstractAbstract Cardiovascular disease is the most important cause of death in the world and encompasses occlusive as well as aneurysmal disease. The most common aneurysm in humans is the abdominal aortic aneurysm (AAA). The question is why the aorta dilates in aneurysmal disease and occ

  14. Ultra Low Density Shape Memory Polymer Foams With Tunable Physicochemical Properties for Treatment of intracranial Aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, Pooja [Texas A & M Univ., College Station, TX (United States)

    2013-12-01

    Shape memory polymers (SMPs) are a rapidly emerging class of smart materials that can be stored in a deformed temporary shape, and can actively return to their original shape upon application of an external stimulus such as heat, pH or light. This behavior is particularly advantageous for minimally invasive biomedical applications comprising embolic/regenerative scaffolds, as it enables a transcatheter delivery of the device to the target site. The focus of this work was to exploit this shape memory behavior of polyurethanes, and develop an efficient embolic SMP foam device for the treatment of intracranial aneurysms.In summary, this work reports a novel family of ultra low density polymer foams which can be delivered via a minimally invasive surgery to the aneurysm site, actuated in a controlled manner to efficiently embolize the aneurysm while promoting physiological fluid/blood flow through the reticulated/open porous structure, and eventually biodegrade leading to complete healing of the vasculature.

  15. ANEURYSMAL BONE CYST OF THE CLAVICLE IN CHILDREN (CLINICAL CASES AND TREATMENT

    Directory of Open Access Journals (Sweden)

    Тимур Фаизович Зубаиров

    2014-09-01

    Full Text Available The purpose. To examine the results of the treatment of children with aneurysmal cyst of the clavicle. Material and methods. The results of examination and treatment of patients aged 16 and 17 years with a diagnosis of aneurysmal cyst of the clavicle. All patients underwent surgical treatment with the ABC stage delimitation. We used a surgical technique, which consists in open removement of the abnormal tissue with replacement of the bone defect with bone-plastic material or autogenous bone from the iliac crest. Conclusions. The method of treatment of aneurysmal bone cyst of the clavicle must be individualized depending on the location, aggressiveness and extent of the lesion. The use bone-plastic material or autogenous bone from the iliac crest restore the structural integrity of a compromised clavicle gives good results in the observation period of up to 2 years.

  16. Cardiovascular syphilis complicated by Lower thoracic and upper abdominal aneurysm – A rare case report

    Directory of Open Access Journals (Sweden)

    K Gayathri

    2016-01-01

    Full Text Available A 50-year-old male presented with left lower abdominal pain, visible pulsation below xiphoid process, and tenderness in the left iliac fossa for the past 10 days. Chest X-ray revealed blunting of left cardiophrenic angle. Echocardiogram revealed descending thoracic aortic pseudoaneurysm. Contrast-enhanced computed tomography of the chest and abdomen revealed dissecting aneurysm of lower thoracic and upper abdominal aorta. Thoracoabdominal aortogram revealed erosion of D12 vertebra and infected aneurysm of adjacent thoracoabdominal aorta. Serum venereal disease research laboratory assay was positive in 1:4 dilution Treponema pallidum hemagglutination assay was positive. The patient was treated with Injection procaine penicillin for 20 days undercover of steroids. Cerebrospinal fluid analysis was normal. Aortic aneurysm repair with reconstruction was done. Histopathology was in favor of syphilitic etiology. This case is being presented as descending thoracic and upper abdominal aortic aneurysm due to syphilis complicated by dissection and erosion of vertebral body is rare and has not been reported nowadays to the best of our knowledge.

  17. Family history of atherosclerotic vascular disease is associated with the presence of abdominal aortic aneurysm.

    Science.gov (United States)

    Ye, Zi; Bailey, Kent R; Austin, Erin; Kullo, Iftikhar J

    2016-02-01

    We investigated whether family history (FHx) of atherosclerotic cardiovascular disease (ASCVD) was associated with presence of abdominal aortic aneurysm (AAA). The study cohort comprised of 696 patients with AAA (70±8 years, 84% men) and 2686 controls (68±10 years, 61% men) recruited from noninvasive vascular and stress electrocardiogram (ECG) laboratories at Mayo Clinic. AAA was defined as a transverse diameter of abdominal aorta ⩾ 3 cm or history of AAA repair. Controls were not known to have AAA. FHx was defined as having at least one first-degree relative with aortic aneurysm or with onset of ASCVD (coronary, cerebral or peripheral artery disease) before age 65 years. FHx of aortic aneurysm or ASCVD were each associated with presence of AAA after adjustment for age, sex, conventional risk factors and ASCVD: adjusted odds ratios (OR; 95% confidence interval): 2.17 (1.66-2.83, p aortic aneurysm: adjusted OR: 1.27 (1.05-1.55, p = 0.01). FHx of ASCVD in multiple arterial locations was associated with higher odds of having AAA: the adjusted odds were 1.23 times higher for each additionally affected arterial location reported in the FHx (1.08-1.40, p = 0.01). Our results suggest both unique and shared environmental and genetic factors mediating susceptibility to AAA and ASCVD.

  18. Aneurysms of medium-sized arteries in Marfan syndrome.

    Science.gov (United States)

    Awais, Mazen; Williams, David M; Deeb, G Michael; Shea, Michael J

    2013-11-01

    Marfan syndrome is a relatively common connective tissue disorder that causes skin, ocular, skeletal, and cardiovascular abnormalities. High morbidity and mortality occur with aortic aneurysm and dissection. Other large-artery aneurysms, including carotid, subclavian, and iliac artery aneurysms, have also been associated with Marfan syndrome. It is not clear whether small- to medium-sized artery aneurysms are associated with Marfan syndrome. This report describes 4 patients with Marfan syndrome who have associated small- to medium-sized artery aneurysms with several complications. Additional investigations are needed to determine whether Marfan syndrome can cause small- to medium-sized artery aneurysms and how patients with these aneurysms should be treated.

  19. Growth rates of intracranial aneurysms : exploring constancy

    NARCIS (Netherlands)

    Koffijberg, Hendrik; Buskens, Erik; Algra, Ale; Wermer, Marieke J. H.; Rinkel, Gabriel J. E.

    2008-01-01

    Object. The annual rate of rupture of intracranial aneurysms is often assumed to be constant, but it is unknown whether this assumption is true. Recent case reports have suggested that aneurysms grow fast in a short period of time. The authors of the present report investigated the plausibility of a

  20. [Gigantic aneurysm of the popliteal artery].

    Science.gov (United States)

    Fernández-Samos, R; Zorita, A; Vázquez, J G; Morán, C; Vaquero, F

    1990-01-01

    A giant popliteal aneurysm case, whose first symptom was an acute ischemia on the limb, caused by thrombosis, which was successfully treated, is reported. Although popliteal aneurysm is not a rare event, the interest of this case is focused on its extraordinary size and unique location.