WorldWideScience

Sample records for analyzing power

  1. Nuclear power plant analyzer

    International Nuclear Information System (INIS)

    Stritar, A.

    1986-01-01

    The development of Nuclear Power Plant Analyzers in USA is described. There are two different types of Analyzers under development in USA, the forst in Idaho and Los Alamos national Lab, the second in brookhaven National lab. That one is described in detail. The computer hardware and the mathematical models of the reactor vessel thermalhydraulics are described. (author)

  2. Loviisa nuclear power plant analyzer

    International Nuclear Information System (INIS)

    Porkholm, K.; Nurmilaukas, P.; Tiihonen, O.; Haenninen, M.; Puska, E.

    1992-12-01

    The APROS Simulation Environment has been developed since 1986 by Imatran Voima Oy (IVO) and the Technical Research Centre of Finland (VTT). It provides tools, solution algorithms and process components for use in different simulation systems for design, analysis and training purposes. One of its main nuclear applications is the Loviisa Nuclear Power Plant Analyzer (LPA). The Loviisa Plant Analyzer includes all the important plant components both in the primary and in the secondary circuits. In addition, all the main control systems, the protection system and the high voltage electrical systems are included. (orig.)

  3. Development and Operation of Dual-Mode Analyzers for Wireless Power Consortium/Power Matters Alliance Wireless Power Systems.

    Science.gov (United States)

    Um, Keehong

    2016-05-01

    We have designed a protocol analyzer to be used in wireless power systems and analyzed the operation of wireless chargers defined by standards of Qi of Wireless Power Consortium (WPC) and Power Matters Alliance (PMA) protocols. The integrated circuit (IC, or microchip) developed so far for wireless power transmission is not easily adopted by chargers for specific purposes. A device for measuring the performance of test equipment currently available is required to transform and expand the types of protocol. Since a protocol analyzer with these functions is required, we have developed a device that can analyze the two protocols of WPC and PMA at the same time. As a result of our research, we present a dual-mode system that can analyze the protocols of both WPC and PMA.

  4. Evaluation of the three-nucleon analyzing power puzzle

    International Nuclear Information System (INIS)

    Tornow, W.; Witala, H.

    1998-01-01

    The current status of the three-nucleon analyzing power puzzle is reviewed. Applying tight constraints on the allowed deviations between calculated predictions and accepted values for relevant nucleon-nucleon observables reveals that energy independent correction factors applied to the 3 P j nucleon-nucleon interactions can not solve the puzzle. Furthermore, using the same constraints, charge-independence breaking in the 3 P j nucleon-nucleon interactions can be ruled out as a possible tool to improve the agreement between three-nucleon calculations and data. The study of the energy dependence of the three-nucleon analyzing power puzzle gives clear evidence that the 3 P j nucleon-nucleon interaction obtained from phase-shift analyses and used in potential models are correct above about 25 MeV, i.e., the 3 P j nucleon-nucleon interactions have to be modified only at lower energies in order to solve the three-nucleon analyzing power puzzle, unless new three-nucleon forces can be found that account for the three-nucleon analyzing power puzzle without destroying the beautiful agreement between rigorous three-nucleon calculations and a large body of accurate three-nucleon data. (orig.)

  5. Evaluation of the three-nucleon analyzing power puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W. [Duke Univ., Durham, NC (United States). Dept. of Physics]|[Triangle Univ. Nuclear Lab., Durham, NC (United States); Witala, H. [Uniwersytet Jagiellonski, Cracow (Poland). Inst. Fizyki

    1998-07-20

    The current status of the three-nucleon analyzing power puzzle is reviewed. Applying tight constraints on the allowed deviations between calculated predictions and accepted values for relevant nucleon-nucleon observables reveals that energy independent correction factors applied to the {sup 3}P{sub j} nucleon-nucleon interactions can not solve the puzzle. Furthermore, using the same constraints, charge-independence breaking in the {sup 3}P{sub j} nucleon-nucleon interactions can be ruled out as a possible tool to improve the agreement between three-nucleon calculations and data. The study of the energy dependence of the three-nucleon analyzing power puzzle gives clear evidence that the {sup 3}P{sub j} nucleon-nucleon interaction obtained from phase-shift analyses and used in potential models are correct above about 25 MeV, i.e., the {sup 3}P{sub j} nucleon-nucleon interactions have to be modified only at lower energies in order to solve the three-nucleon analyzing power puzzle, unless new three-nucleon forces can be found that account for the three-nucleon analyzing power puzzle without destroying the beautiful agreement between rigorous three-nucleon calculations and a large body of accurate three-nucleon data. (orig.) 18 refs.

  6. Proton--proton analyzing power measurements at 16 MeV

    International Nuclear Information System (INIS)

    Lovoi, P.A.

    1975-01-01

    Few attempts have been made to measure accurately the proton--proton analyzing powers at low energies. With the advent of polarized particle beams the measurement can now be made with high accuracy. Analyzing powers were measured at nine scattering angles from 10 0 to 35 0 in the laboratory system. As a check on systematic errors, analyzing power measurements were also made by scattering protons from 4 He. In the p vector-p case the measured values are in very good agreement with the phase shift predictions. The p vector- 4 He measurements, while giving the same form and sign as the phase shift predictions, differ from the predictions by as much as 11 standard deviations. The p vector-p analyzing powers had a maximum value of -0.0043 +- 0.0004 at 10 0 (laboratory) and decreased to zero near 25 0 . A new technique to measure analyzing powers without symmetric detectors is explained. This technique preserves the advantages of the symmetric arm method in that current integration, target density, detector efficiencies, and geometry are cancelled from the final expressions. A new scattering chamber, named the Supercube, is described. The Supercube was designed primarily to perform scattering experiments with a polarized beam. It contains both left-right and up-down detectors for use with both spin- 1 / 2 and spin-1 measurements. The Supercube was designed to make analyzing power measurements to an accuracy of 0.001 routine. The Supercube has proved to have low systematic errors and to perform as expected. The systematic errors were found to be equal to or less than 0.0002

  7. Proton--proton analyzing power measurements at 16 MeV

    International Nuclear Information System (INIS)

    Lovoi, P.A.

    1975-07-01

    Few attempts have been made to measure accurately the proton-proton analyzing powers at low energies. With the advent of polarized particle beams the measurement can now be made with high accuracy. Analyzing powers were measured at nine scattering angles from 10 0 to 35 0 in the laboratory system. As a check on systematic errors, analyzing power measurements were also made by scattering protons from 4 He. In the p Vector-p case the measured values are in very good agreement with the phase shift predictions. The p Vector- 4 He measurements, while giving the same form and sign as the phase shift predictions, differ from the predictions by as much as 11 standard deviations. The p Vector-p analyzing powers had a maximum value of -0.0043 +- 0.0004 at 10 0 (laboratory) and decreased to zero near 25 0 . A new technique to measure analyzing powers without symmetric detectors is explained. This technique preserves the advantages of the symmetric arm method in that current integration, target density, detector efficiencies, and geometry are cancelled from the final expressions. A new scattering chamber, named the Supercube, is described. The Supercube was designed primarily to perform scattering experiments with a polarized beam. It contains both left-right and up-down detectors for use with both spin-1/2 and spin-1 measurements. The Supercube was designed to make analyzing power measurements to an accuracy of 0.001 routine. The Supercube has proved to have low systematic errors and to perform as expected. The systematic errors were found to be equal to or less than 0.0002. (23 figures, 14 tables) (auth)

  8. Computer program analyzes and monitors electrical power systems (POSIMO)

    Science.gov (United States)

    Jaeger, K.

    1972-01-01

    Requirements to monitor and/or simulate electric power distribution, power balance, and charge budget are discussed. Computer program to analyze power system and generate set of characteristic power system data is described. Application to status indicators to denote different exclusive conditions is presented.

  9. np elastic scattering analyzing power characteristics at intermediate energies

    International Nuclear Information System (INIS)

    Abegg, R.; Davis, C.A.; Delheij, P.P.J.; Green, P.W.; Greeniaus, L.G.; Healey, D.C.; Miller, C.A.; Rodning, N.L.; Wait, G.D.; Ahmad, M.; Cairns, E.B.; Coombes, G.H.; Lapointe, C.; McDonald, W.J.; Moss, G.A.; Roy, G.; Soukup, J.; Tkachuk, R.R.; Ye, Y.; Watson, J.W.

    1989-06-01

    Recent measurements of charge symmetry breaking in the np system at 477 MeV, and of A oonn for np elastic scattering at 220, 325 and 425 MeV also yield accurate analyzing power data. These data allow the energy dependence of the analyzing power zero-crossing angle and the slope of the analyzing power at the zero-crossing to be determined. The incident neutron energies span a region where the zero-crossing angle is strongly energy dependent (Ε n n > 350 MeV). The results are compared to current phase shift analysis predictions, recently published LAMPF data, and the predictions of the Bonn and Paris potentials. (Author) 13 refs., 2 tabs., 2 figs

  10. A low power Multi-Channel Analyzer

    International Nuclear Information System (INIS)

    Anderson, G.A.; Brackenbush, L.W.

    1993-06-01

    The instrumentation used in nuclear spectroscopy is generally large, is not portable, and requires a lot of power. Key components of these counting systems are the computer and the Multi-Channel Analyzer (MCA). To assist in performing measurements requiring portable systems, a small, very low power MCA has been developed at Pacific Northwest Laboratory (PNL). This MCA is interfaced with a Hewlett Packard palm top computer for portable applications. The MCA can also be connected to an IBM/PC for data storage and analysis. In addition, a real-time time display mode allows the user to view the spectra as they are collected

  11. Free neutron-proton analyzing power at medium energies

    International Nuclear Information System (INIS)

    Newsom, C.R.

    1980-01-01

    In recent years, increasing efforts have been made to measure the nucleon-nucleon polarization parameters. To date, no free neutron-proton spin correlated parameters have been published in the energy range 500 to 800 MeV. Existing analyzing power data is of low precision and in most cases was obtained by quasi-free proton scattering. As a first step in determining the neutron-proton scattering matrix, the free neutron-proton analyzing power has been measured at the Los Alamos Physics Facility as a function of energy and angle. The experiment was performed by scattering a neutron beam from a polarized proton target. The neutron beam was generated by scattering 800 MeV protons from a Beryllium target and using the neutrons produced at 0 degrees. The incident energy ranged from 300 MeV to 800 MeV. The energy spread of the neutron beam made it possible to measure the analyzing power at different energies simultaneously. Angular distributions were taken from 60 to 170 degrees in the center of mass system (c.m.)

  12. Analyzing Power Supply and Demand on the ISS

    Science.gov (United States)

    Thomas, Justin; Pham, Tho; Halyard, Raymond; Conwell, Steve

    2006-01-01

    Station Power and Energy Evaluation Determiner (SPEED) is a Java application program for analyzing the supply and demand aspects of the electrical power system of the International Space Station (ISS). SPEED can be executed on any computer that supports version 1.4 or a subsequent version of the Java Runtime Environment. SPEED includes an analysis module, denoted the Simplified Battery Solar Array Model, which is a simplified engineering model of the ISS primary power system. This simplified model makes it possible to perform analyses quickly. SPEED also includes a user-friendly graphical-interface module, an input file system, a parameter-configuration module, an analysis-configuration-management subsystem, and an output subsystem. SPEED responds to input information on trajectory, shadowing, attitude, and pointing in either a state-of-charge mode or a power-availability mode. In the state-of-charge mode, SPEED calculates battery state-of-charge profiles, given a time-varying power-load profile. In the power-availability mode, SPEED determines the time-varying total available solar array and/or battery power output, given a minimum allowable battery state of charge.

  13. Analyzing Single-Event Gate Ruptures In Power MOSFET's

    Science.gov (United States)

    Zoutendyk, John A.

    1993-01-01

    Susceptibilities of power metal-oxide/semiconductor field-effect transistors (MOSFET's) to single-event gate ruptures analyzed by exposing devices to beams of energetic bromine ions while applying appropriate bias voltages to source, gate, and drain terminals and measuring current flowing into or out of each terminal.

  14. ANALYZER OF QUANTITY AND QUALITY OF THE ELECTRIC POWER

    Directory of Open Access Journals (Sweden)

    A. I. Semilyak

    2013-01-01

    Full Text Available One of the activities of the research center for “Energy Saving Technologies and Smart Metering in Electrical Power Engineering" is research work on the use of electronic devices and systems of intelligent power distribution, produced by Analog Devices and equipped with the accurate energy consumption measurement feature. The article focuses on the development of the analyzer of quantity and quality of electric energy.The main part of the analyzer is a metering IC by Analog Devices ADE7878, designed for use in commercial and industrial smart electricity meters. Such counters measure the amount of consumed or produced electric energy with high accuracy and have the means of remote meter reading.

  15. Analyzing powers in the dd→3Hen(3Hp) reactions at intermediate energies

    International Nuclear Information System (INIS)

    Ladygin, V. P.; Kiselev, A. S.; Kurilkin, A. K.; Vasiliev, T. A.; Isupov, A. Yu.; Ladygina, N. B.; Malakhov, A. I.; Reznikov, S. G.; Uesaka, T.; Saito, T.; Hatano, M.; Kato, H.; Sakoda, S.; Uchigashima, N.; Yako, K.; Janek, M.; Maeda, Y.; Nishikawa, J.; Ohnishi, T.; Sakamoto, N.

    2008-01-01

    Data for the deuteron analyzing powers in the dd→ 3 Hen( 3 Hp) reactions obtained at 140-270 MeV are discussed. The observed negative sign of the tensor analyzing powers A yy , A xx and A xz at small angles clearly demonstrate the sensitivity to the ratio of the D and S state components of the 3 He wave function. The behavior of the tensor analyzing powers at backward angles is sensitive to the short-range spin structure of the deuteron. However, the one-nucleon exchange calculations using standard 3 He and deuteron wave functions fail to reproduce the strong variation of the tensor analyzing powers as a function of angle in the cms. Sensitivity to relativistic effects is also discussed

  16. Forward angle quasi-free proton-neutron analyzing powers at 0.8 GeV

    International Nuclear Information System (INIS)

    Barlett, M.L.

    1981-01-01

    As the first step in determining the nucleon-nucleon scattering amplitudes at small momentum transfers at 0.8 GeV, quasi-free p vector + n and p vector + p analyzing powers were obtained at laboratory scattering angles from 6 0 to 32.9 0 by scattering 800-MeV polarized protons from a liquid deuterium target. Forward-scattered protons were detected by the High Resolution Spectrometer (HRS), while recoil neutrons and protons were detected in coincidence with the event detected with the HRS by a 5 x 5 array of scintillators. A thin scintillator placed between the target and the array enabled discrimination of recoil particle type and facilitated the simultaneous measurement of both p vector n and n vector p analyzing powers. A comparison of the results with previously measured free p vector p and n vector p analyzing powers shows excellent agreement between the free and quasi-free p vector p analyzing powers. Poorer agreement is seen for the p vector n analyzing powers. The results of phase-shift analyses are presented in order to study the effects of the quasi-free analyzing power measurements on the determination of the pn scattering amplitudes. Amplitudes obtained from the phase-shift analyses are then used in KMT calculations. The results indicate that further nucleon-nucleon measurements are necessary in order to determine the nucleon-nucleon amplitudes unambiguously at 800 MeV

  17. Time-reversal asymmetry: polarization and analyzing power in nuclear reactions

    International Nuclear Information System (INIS)

    Rioux, C.; Roy, R.; Slobodrian, R.J.; Conzett, H.E.

    1984-01-01

    Measurements of the proton polarization in the reactions 7 Li( 3 He, p vector) 9 Be and 9 Be( 3 He, p vector) 11 B and of the analyzing powers in the inverse reactions, initiated by polarized protons at the same center-of-mass energies, show significant differences. This implies the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction 2 H( 3 He, p vector) 4 He and its inverse have also been investigated and show smaller differences. A discussion of instrumental asymmetries is presented

  18. Time asymmetry: Polarization and analyzing power in the nuclear reactions

    International Nuclear Information System (INIS)

    Rioux, C.; Roy, R.; Slobodrian, R.J.; Conzett, H.E.

    1983-01-01

    Measurements of the proton polarization in the reactions 7 Li( 3 He, p vector) 9 Be and 9 Be( 3 He, p vector) 11 B and of the analyzing powers of the inverse reactions, initiated by polarized protons at the same c.m. energies, show significant differences which imply the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction 2 H( 3 He, p vector) 4 He and its inverse have also been investigated and show some smaller differences. A discussion of the instrumental asymmetries is presented. (orig.)

  19. Regional modeling approach for analyzing harmonic stability in radial power electronics based power system

    DEFF Research Database (Denmark)

    Yoon, Changwoo; Bai, Haofeng; Wang, Xiongfei

    2015-01-01

    Stability analysis of distributed power generation system becomes complex when there are many numbers of grid inverters in the system. In order to analyze system stability, the overall network impedance will be lumped and needs to be analyzed one by one. However, using a unified bulky transfer-fu...... and then it is expanded for generalizing its concept to an overall radial structured network....

  20. Time asymmetry: Polarization and analyzing power in the nuclear reactions

    Energy Technology Data Exchange (ETDEWEB)

    Rioux, C.; Roy, R.; Slobodrian, R.J. (Laval Univ., Quebec City (Canada). Lab. de Physique Nucleaire); Conzett, H.E. (California Univ., Berkeley (USA). Lawrence Berkeley Lab.)

    1983-02-28

    Measurements of the proton polarization in the reactions /sup 7/Li(/sup 3/He, p vector)/sup 9/Be and /sup 9/Be(/sup 3/He, p vector)/sup 11/B and of the analyzing powers of the inverse reactions, initiated by polarized protons at the same c.m. energies, show significant differences which imply the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction /sup 2/H(/sup 3/He, p vector)/sup 4/ He and its inverse have also been investigated and show some smaller differences. A discussion of the instrumental asymmetries is presented.

  1. Neutron-deuteron analyzing power data at En = 21 MeV and the energy dependence of the three-nucleon analyzing power puzzle

    Science.gov (United States)

    Weisel, G. J.; Tornow, W.; Esterline, J. H.

    2015-08-01

    We present measurements of n-d analyzing power, {A}y(θ ), at En = 21.0 MeV. The experiment produces neutrons via the 2H(d, n)3He reaction and uses a deuterated liquid-scintillator center detector and six pairs of liquid-scintillator neutron side detectors. Elastic neutron scattering events are identified by using time-of-flight techniques and by setting a gate in the center-detector pulse-height spectrum. Beam polarization is monitored by using a high-pressure helium gas scintillator. The n-d {A}y(θ ) data at 21.0 MeV show a significant discrepancy with the results of rigorous three-body calculations and are consistent with data taken previously by us at 19.0 and 22.5 MeV. We review the overall energy dependence of the three-nucleon analyzing power puzzle in neutron-deuteron elastic scattering, using the best data available. We find that the relative difference between calculations and data is nearly constant at 25% up to En = 22.5 MeV.

  2. Los Alamos Nuclear Plant Analyzer: an interactive power-plant simulation program

    International Nuclear Information System (INIS)

    Steinke, R.; Booker, C.; Giguere, P.; Liles, D.R.; Mahaffy, J.H.; Turner, M.R.

    1984-01-01

    The Nuclear Plant Analyzer (NPA) is a computer-software interface for executing the TRAC or RELAP5 power-plant systems codes. The NPA is designed to use advanced supercomputers, long-distance data communications, and a remote workstation terminal with interactive computer graphics to analyze power-plant thermal-hydraulic behavior. The NPA interface simplifies the running of these codes through automated procedures and dialog interaction. User understanding of simulated-plant behavior is enhanced through graphics displays of calculational results. These results are displayed concurrently with the calculation. The user has the capability to override the plant's modeled control system with hardware-adjustment commands. This gives the NPA the utility of a simulator, and at the same time, the accuracy of an advanced, best-estimate, power-plant systems code for plant operation and safety analysis

  3. Nuclear Plant Analyzer: an interactive TRAC/RELAP Power-Plant Simulation Program

    International Nuclear Information System (INIS)

    Steinke, R.; Booker, C.; Giguere, P.; Liles, D.; Mahaffy, J.; Turner, M.; Wiley, R.

    1984-01-01

    The Nuclear Plant Analyzer (NPA) is a computer-software interface for executing the TRAC or RELAP5 power-plant systems codes. The NPA is designed to use advanced supercomputers, long-distance data communications, and a remote workstation terminal with interactive computer graphics to analyze power-plant thermal-hydraulic behavior. The NPA interface simplifies the running of these codes through automated procedures and dialog interaction. User understanding of simulated-plant behavior is enhanced through graphics displays of calculational results. These results are displayed concurrently with the calculation. The user has the capability to override the plant's modeled control system with hardware adjustment commands. This gives the NPA the utility of a simulator, and at the same time, the accuracy of an advanced, best-estimate, power-plant systems code for plant operation and safety analysis

  4. Probing α-particle wave functions by (d,α) tensor analyzing powers

    International Nuclear Information System (INIS)

    Crosson, E.R.; Das, R.K.; Lemieux, S.K.; Ludwig, E.J.; Thompson, W.J.; Bisenberger, M.; Hertenberger, R.; Hofer, D.; Kader, H.; Schiemenz, P.; Graw, G.; Eiro, A.M.; Santos, F.D.

    1992-01-01

    Components of α-particle wave functions corresponding to d-d configurations are used to predict analyzing powers in the (d,α) reaction. Tensor analyzing powers, especially A xx , are shown to clearly distinguish between wave functions generated by different realistic nucleon-nucleon interactions. Data for the 58 Ni(d,α) 56 Co reaction to the 7 + stretched-nucleon-orbital state at 2.283-MeV excitation in 56 Co, measured with 22-MeV deuterons, are compared to predictions from the Argonne and Urbana interactions. Similar comparisons are made to data for the lowest J π =7 + state in 48 Sc populated by the 50 Ti(d,α) 48 Sc reaction at 16 MeV

  5. Unique electron polarimeter analyzing power comparison and precision spin-based energy measurement

    International Nuclear Information System (INIS)

    Joseph Grames; Charles Sinclair; Joseph Mitchell; Eugene Chudakov; Howard Fenker; Arne Freyberger; Douglas Higinbotham; Poelker, B.; Michael Steigerwald; Michael Tiefenback; Christian Cavata; Stephanie Escoffier; Frederic Marie; Thierry Pussieux; Pascal Vernin; Samuel Danagoulian; Kahanawita Dharmawardane; Renee Fatemi; Kyungseon Joo; Markus Zeier; Viktor Gorbenko; Rakhsha Nasseripour; Brian Raue; Riad Suleiman; Benedikt Zihlmann

    2004-01-01

    Precision measurements of the relative analyzing powers of five electron beam polarimeters, based on Compton, Moller, and Mott scattering, have been performed using the CEBAF accelerator at the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory). A Wien filter in the 100 keV beamline of the injector was used to vary the electron spin orientation exiting the injector. High statistical precision measurements of the scattering asymmetry as a function of the spin orientation were made with each polarimeter. Since each polarimeter receives beam with the same magnitude of polarization, these asymmetry measurements permit a high statistical precision comparison of the relative analyzing powers of the five polarimeters. This is the first time a precise comparison of the analyzing powers of Compton, Moller, and Mott scattering polarimeters has been made. Statistically significant disagreements among the values of the beam polarization calculated from the asymmetry measurements made with each polarimeter reveal either errors in the values of the analyzing power, or failure to correctly include all systematic effects. The measurements reported here represent a first step toward understanding the systematic effects of these electron polarimeters. Such studies are necessary to realize high absolute accuracy (ca. 1%) electron polarization measurements, as required for some parity violation measurements planned at Jefferson Laboratory. Finally, a comparison of the value of the spin orientation exiting the injector that provides maximum longitudinal polarization in each experimental hall leads to an independent and very precise (better than 10-4) absolute measurement of the final electron beam energy

  6. p-p analyzing power excitation function between 510 and 725 MeV

    International Nuclear Information System (INIS)

    Beurtey, R.; Arvieux, J.; Boivin, M.; Boyard, J.L.; Durand, J.M.; Combes-Comets, M.P.; Courtat, P.; Gacougnolle, R.; Le Bornec, Y.; Garcon, M.

    1993-01-01

    In an earlier experiment some evidence was observed for narrow dibaryons in the analyzing power excitation function of p-p elastic scattering at √s=2160 MeV and 2192 MeV, with width Γ≅13-14 MeV. A different procedure has been carried out at the SATURNE synchrotron, in order to obtain a very high accuracy of the analyzing power for a large number of energies between 510 and 725 MeV. The results show no evidence for any structure with width ∼5 to 20 MeV. The reasons at the difference between the two experiments are discussed. (K.A.) 2 refs., 3 figs

  7. Angle-averaged effective proton-carbon analyzing powers at intermediate energies

    International Nuclear Information System (INIS)

    Amir-Ahmadi, H.R.; Berg, A.M. van den; Hunyadi, M.; Kalantar-Nayestanaki, N.; Kis, M.; Mahjour-Shafiei, M.; Messchendorp, J.G.; Woertche, H.J.

    2006-01-01

    The angle-averaged effective analyzing powers, A-bar c , for proton-carbon inclusive scattering were measured as a function of the kinetic energy of protons in a double scattering experiment. The measurements were performed in the kinetic energy range of 44.8-136.5MeV at the center of 1-5cm thick graphite analyzers using a polarized proton beam on a CH 2 film or liquid hydrogen serving as target for the primary scattering. These data can be used for measuring the polarization of protons emerging from other reactions such as H(d-bar ,p-bar )d

  8. Tensor analyzing powers in deuteron--proton elastic scattering and the breakup reaction at 45.4 MeV

    International Nuclear Information System (INIS)

    Conzett, H.E.

    1978-08-01

    Recently the tensor analyzing powers in vector d + p elastic scattering and in the breakup reaction at E/sub d/ = 45.4 MeV were measured. The elastic results now establish a rather complete set of polarization data in nucleon--deuteron scattering at E/sub N/ = 22.7 MeV, which consists of the proton analyzing power, the deuteron vector and tensor analyzing powers, and vector polarization transfer measurements, as well. 8 references

  9. Analyzing power for proton elastic scattering from the neutron-rich 6He nucleus

    International Nuclear Information System (INIS)

    Uesaka, T.; Sakaguchi, S.; Kawabata, T.; Sasamoto, Y.; Iseri, Y.; Amos, K.; Aoi, N.; Hiyama, E.; Sekiguchi, K.; Yamaguchi, M.; Hashimoto, Y.; Satou, Y.; Shinohara, M.; Ichikawa, M.; Itoh, M.; Matsuo, R.; Wakui, T.; Ichikawa, Y.; Iwasaki, H.; Kuboki, H.

    2010-01-01

    Vector analyzing power for the proton- 6 He elastic scattering at 71 MeV/nucleon has been measured for the first time, with a newly developed polarized proton solid target, which works at a low magnetic field of 0.09 T. The results are found to be incompatible with a t-matrix folding model prediction. Comparisons of the data with g-matrix folding analyses clearly show that the vector analyzing power is sensitive to the nuclear structure model used in the reaction analysis. The α-core distribution in 6 He is suggested to be a possible key for understanding the nuclear structure sensitivity.

  10. Development of general-purpose software to analyze the static thermal characteristic of nuclear power plant

    International Nuclear Information System (INIS)

    Nakao, Yoshinobu; Koda, Eiichi; Takahashi, Toru

    2009-01-01

    We have developed the general-purpose software by which static thermal characteristic of the power generation system is analyzed easily. This software has the notable features as follows. It has the new algorithm to solve non-linear simultaneous equations to analyze the static thermal characteristics such as heat and mass balance, efficiencies, etc. of various power generation systems. It has the flexibility for setting calculation conditions. It is able to be executed on the personal computer easily and quickly. We ensured that it is able to construct heat and mass balance diagrams of main steam system of nuclear power plant and calculate the power output and efficiencies of the system. Furthermore, we evaluated various heat recovery measures of steam generator blowdown water and found that this software could be a useful operation aid for planning effective changes in support of power stretch. (author)

  11. On the nuclear shell effects appeared in (p,t) analyzing power calculations

    International Nuclear Information System (INIS)

    Kubo, Ken-ichi

    1980-01-01

    Origin of shell effects found in two-step (p, d, t) calculation, which play an important role for understanding the observed 'anomalous' (p, t) analyzing powers, is clarified based on the selections for transferred angular momenta. (author)

  12. Using Model Checking for Analyzing Distributed Power Control Problems

    Directory of Open Access Journals (Sweden)

    Thomas Brihaye

    2010-01-01

    Full Text Available Model checking (MC is a formal verification technique which has been known and still knows a resounding success in the computer science community. Realizing that the distributed power control (PC problem can be modeled by a timed game between a given transmitter and its environment, the authors wanted to know whether this approach can be applied to distributed PC. It turns out that it can be applied successfully and allows one to analyze realistic scenarios including the case of discrete transmit powers and games with incomplete information. The proposed methodology is as follows. We state some objectives a transmitter-receiver pair would like to reach. The network is modeled by a game where transmitters are considered as timed automata interacting with each other. The objectives are then translated into timed alternating-time temporal logic formulae and MC is exploited to know whether the desired properties are verified and determine a winning strategy.

  13. A Low Cost Shading Analyzer and Site Evaluator Design to Determine Solar Power System Installation Area

    Directory of Open Access Journals (Sweden)

    Selami Kesler

    2015-01-01

    Full Text Available Shading analyzer systems are necessary for selecting the most suitable installation site to sustain enough solar power. Afterwards, changes in solar data throughout the year must be evaluated along with the identification of obstructions surrounding the installation site in order to analyze shading effects on productivity of the solar power system. In this study, the shading analysis tools are introduced briefly, and a new and different device is developed and explained to analyze shading effect of the environmental obstruction on the site on which the solar power system will be established. Thus, exposure duration of the PV panels to the sunlight can be measured effectively. The device is explained with an application on the installation area selected as a pilot site, Denizli, in Turkey.

  14. Vector analyzing power in elastic electron-proton scattering

    International Nuclear Information System (INIS)

    Diaconescu, L.; Ramsey-Musolf, M.J.

    2004-01-01

    We compute the vector analyzing power (VAP) for the elastic scattering of transversely polarized electrons from protons at low energies using an effective theory of electrons, protons, and photons. We study all contributions through second order in E/M, where E and M are the electron energy and nucleon mass, respectively. The leading-order VAP arises from the imaginary part of the interference of one- and two-photon exchange amplitudes. Subleading contributions are generated by the nucleon magnetic moment and charge radius as well as recoil corrections to the leading-order amplitude. Working to O(E/M) 2 , we obtain a prediction for A n that is free of unknown parameters and that agrees with the recent measurement of the VAP in backward angle ep scattering

  15. Analyzing power measurements in the (p,α) reaction on sup(58,60,62)Ni and 54Fe

    International Nuclear Information System (INIS)

    Katori, K.; Tagishi, Y.; Toba, Y.; Sasagase, M.; Sato, M.

    1980-01-01

    Two topics are discussed: (1) Analyzing powers for the (p, α) reactions on sup(58,60,62)Ni at E sub(p) = 22 MeV and (2) Excitation of the analog state in the 54 Fe(p, α) 51 Mn reaction at E sub(p) = 21 MeV. For the first topic, isotope (sup(58,60,62)Ni) and orbit (0f sub(7/2), 1s sub(1/2) and 0d sub(3/2)) dependences on angular distributions were compared for analyzing powers and cross sections. All the measured analyzing powers could not be reproduced within the frame work of a simple DWBA calculation. For the second topic, spin and parity of a state at 4.459 MeV in 51 Mn (the analog of the ground state of the 51 Cr nucleus) were assigned to be 7/2 - by the measurements of the analyzing power and cross section. (author)

  16. Neutron-deuteron analyzing power data at En=22.5 MeV

    Science.gov (United States)

    Weisel, G. J.; Tornow, W.; Crowell, A. S.; Esterline, J. H.; Hale, G. M.; Howell, C. R.; O'Malley, P. D.; Tompkins, J. R.; Witała, H.

    2014-05-01

    We present measurements of n-d analyzing power, Ay(θ), at En=22.5 MeV. The experiment uses a shielded neutron source which produced polarized neutrons via the 2H(d⃗,n⃗)3He reaction. It also uses a deuterated liquid-scintillator center detector and six pairs of liquid-scintillator neutron side detectors. Elastic neutron scattering events are identified by using time-of-flight techniques and by setting a window in the center detector pulse-height spectrum. The beam polarization is monitored by using a high-pressure helium gas cell and an additional pair of liquid-scintillator side detectors. The n-d Ay(θ) data were corrected for finite-geometry and multiple-scattering effects using a Monte Carlo simulation of the experiment. The 22.5-MeV data demonstrate that the three-nucleon analyzing power puzzle also exists at this energy. They show a significant discrepancy with predictions of high-precision nucleon-nucleon potentials alone or combined with Tucscon-Melbourne or Urbana IX three-nucleon forces, as well as currently available effective-field theory based potentials of next-to-next-to-next-to-leading order.

  17. Analyzing power measurements for the (π+,π0) reaction on a polarized 13C target

    International Nuclear Information System (INIS)

    Goergen, J.J.

    1991-05-01

    The analyzing powers A y differential cross sections dσ/dΩ for the reaction 13 C(π + ,π 0 ) 13 N have been measured for forward scattering angles at an incident pion kinetic energy of T pi + = 163 MeV by using a transversely polarized target. Analyzing powers and reaction cross sections impose stringent constrains on nuclear reaction models and can be used to test the present understanding of nuclear structure for 1p-shell nuclei. The resulting A y are compared to the predictions of first-order Distorted Wave Impulse Approximation (DWIA) calculations, which reproduce well the differential cross sections. Although there is qualitative agreement at forward angles, the quantitative agreement is poor, especially at scattering angles larger than 50 degrees. Since the DWIA calculations do not appear to be strongly sensitive to the assumed nuclear structure model, the discrepancy in describing the analyzing powers suggests that the reaction mechanism may not yet be well understood and higher order corrections may be important. Also measured were the analyzing powers for the elementary charge exchange reaction π - bar p → π degrees n over the same angular range and at an incident pion kinetic energy of T pi - = 161 MeV. The results are compared to the most recents phase shift predictions. Within the experimental uncertainties, phase shift calculations agree with the measured A y and no changes in the πN phase shifts near the P 33 resonance are needed to describe the data

  18. Analyzing power in pp scattering at low energies: the Paris potential predictions

    International Nuclear Information System (INIS)

    Cote, J.; Pires, P.; Tourreil, R. de; Lacombe, M.; Loiseau, B.; Vinh Mau, R.

    1979-12-01

    Predictions of the Paris potential for the analyzing power in pp scattering at low energies are compared with recent high precision measurements at 6.14MeV and earlier measurements at 10 and 16MeV. Phase shift values are also presented and discussed in view of previous analyses

  19. Analyzing powers Ayy, Axx, Axz and Ay in the dd→3Hen reaction at 270 MeV

    International Nuclear Information System (INIS)

    Janek, M.; Saito, T.; Hatano, M.; Kato, H.; Sakoda, S.; Uchigashima, N.; Yako, K.; Ladygin, V.P.; Isupov, A. Yu.; Ladygina, N.B.; Malakhov, A.I.; Reznikov, S.G.; Vasiliev, T.A.; Uesaka, T.; Maeda, Y.; Suda, K.; Nishikawa, J.; Ohnishi, T.; Sakamoto, N.; Sekiguchi, K.; Okamura, H.; Sakai, H.

    2007-01-01

    The data on the tensor A yy , A xx , A xz and vector A y analyzing powers in the dd → 3 Hen obtained at T d =270 MeV in the angular range 0 -110 in the c.m. are presented. The observed negative sign of the tensor analyzing powers A yy , A xx and A xz at small angles clearly demonstrate the sensitivity to the ratio of the D- and S-wave component of the 3 He wave function. However, the one-nucleon exchange calculations by using the standard 3 He wave functions have failed to reproduce the strong variation of the tensor analyzing powers as a function of the angle in the c.m. (orig.)

  20. Analyzing powers Ayy, Axx, Axz and Ay in the dd→3Hen reaction at 270 MeV

    International Nuclear Information System (INIS)

    Janek, M.; Saito, T.; Ladygin, V.P.

    2007-01-01

    The data on the tensor A yy , A xx , A xz and vector A y analyzing powers in the dd→ 3 Hen reaction obtained at T d =270 MeV in the angular range 0-110 deg in the c.m. are presented. The observed negative sign of the tensor analyzing powers A yy , A xx and A xz at small angles clearly demonstrates the sensitivity to the ratio of the D- and S-wave component of the 3 He wave function. However, the one-nucleon exchange calculations by using the standard 3 He wave functions have failed to reproduce the strong variation of the tensor analyzing powers as a function of the angle in the c.m

  1. Concerning tests of time-reversal invariance via the polarization-analyzing power equality

    International Nuclear Information System (INIS)

    Conzett, H.E.

    1982-01-01

    Previous tests of time-reversal invariance via comparisons of polarizations and analyzing powers in nuclear scattering have been examined. It is found that all of these comparisons fail as adequate tests of time-reversal invariance either because of a lack of experimental precision or the lack of sensitivity to any time-reversal symmetry violation

  2. Analyzing powers for the three-nucleon breakup reaction 1H(d vector,p)pn at 16 MeV

    International Nuclear Information System (INIS)

    Brown, R.E.; Ohlsen, G.G.; Correll, F.D.; Hardekopf, R.A.; Jarmie, N.

    1980-01-01

    Analyzing powers for the 1 H(d,p)pn reaction were measured at 16.0 MeV and beam polarization of approximately 0.82. Similar data for the elastic scattering 1 H(d,p) 2 H were also taken. The breakup analyzing power A/sub xz/, which attains the largest magnitude, is shown as a function of excitation energy. Angular distributions of elastic and breakup analyzing powers are compared; large differences are noted for A/sub xx/ and A/sub xz/. It is found that 1-MeV energy bins are too large to use in the study of singlet-state effects. 2 figures

  3. Analyzing power measurements for neutron-nucleus scattering and the spin-orbit potential

    International Nuclear Information System (INIS)

    Walter, R.L.

    1985-01-01

    Analyzing power A/sub y/(theta) and cross section measurements have been obtained from 10 to 17 MeV for 20 isotopes ranging from 6 Li to 208 Pb. These combined data sets provide a unique data base for nuclear model development. The experimental method for the A/sub y/(theta) measurements and comparisons to coupled-channels and spherical optical model calculations are given

  4. Analyzing powers in π+p elastic scattering at intermediate energies

    International Nuclear Information System (INIS)

    Mokhtari, A.; Briscoe, W.J.; Eichon, A.D.

    1985-01-01

    The analyzing power, A/sub N/, has been measured for π + p elastic scattering at p/sub π/ = 471, 547, 625, and 687 MeV/c on a transversely polarized target. The results are compared with three recent partial-wave analyses for the isospin (3/2) channel. The agreement with our data for all three analyses is good at 471 MeV/c and reasonable at 547 and 625 MeV/c. At 687 MeV/c two of the analyses show a sharp maximum near costheta = -0.4 which is not seen in the data. There is no indication in our data of the existence of new, narrow Δ resonances

  5. EPRI compact analyzer: A compact, interactive and color-graphics based simulator for power plant analysis

    International Nuclear Information System (INIS)

    Ipakchi, A.; Khadem, M.; Chen, H.; Colley, R.W.

    1986-01-01

    This paper presents the results of an EPRI sponsored project (RP2395-2) for design and development of an interactive, and color graphics based simulator for power plant analysis. The system is called Compact Analyzer and can be applied to engineering and training applications in the utility industry. The Compact Analyzer's software and system design are described. Results of two demonstration system for a nuclear plant, and a fossil plant are presented, and the applications of the Compact Analyzer to operating procedures evaluation are discussed

  6. Tensor analyzing power in backward pd elastic scattering and its connection to pp → πd at intermediate energies

    International Nuclear Information System (INIS)

    Nakamura, A.; Satta, L.

    1985-03-01

    The tensor analyzing power for pd backward elastic scattering is calculated in the energy range 150 <= Tsub(p) <= 800 MeV. Two main contributions are considered: the one nucleon exchange and the so called triangle graph, including pp → πd as a subprocess. The pd backward elastic cross section and tensor analyzing power are fairly well reproduced by the model. (author)

  7. A new twist to the long-standing three-nucleon analyzing power puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Neidel, E.M.; Tornow, W.; Gonzalez Trotter, D.E.; Howell, C.R.; Crowell, A.S.; Macri, R.A.; Walter, R.L.; Weisel, G.J.; Esterline, J.; Witala, H.; Crowe, B.J.; Pedroni, R.S.; Markoff, D.M

    2003-01-16

    New results for the neutron-deuteron analyzing power A{sub y}({theta}) at E{sub n}=1.2 and 1.9 MeV and their comparison to proton-deuteron data reveal a sizeable and unexpected difference which increases with decreasing center-of-mass energy. This finding calls for the theoretical treatment of a subtle electromagnetic effect presently not incorporated in rigorous three-nucleon scattering calculations, before it is justified to invoke charge-dependent three-nucleon forces and/or other new physics.

  8. Program for analyzing power boost tests

    International Nuclear Information System (INIS)

    Wills, C.A.

    1982-03-01

    A rapid increase of power in a reactor produces a failure in the fuel. Experiments to study the conditions in the NRU reactor after such failures have been planned and carried out. Given the concentrations of specified isotopes at a number of times over the length of an experiment as produced for example, from the program SARGS and the power history of the reactor, this program calculates the release rates, escape rate coefficients, and fractional releases for the isotopes. These values may be optionally printed and plotted. Decay schemes for a limited number of mass numbers are implemented. The program is written in FORTRAN and runs on the CDC 6600 - CYBER 170 system

  9. Measurement of the free neutron-proton analyzing power and spin transfer parameters in the charge exchange region at 790 MeV

    International Nuclear Information System (INIS)

    Ransome, R.D.

    1981-07-01

    The free neutron-proton analyzing power and the spin transfer parameters (K/sub NN/, K/sub SS/, K/sub SL/, and K/sub LL/) were measured at the Los Alamos Meson Physics Facility at 790 MeV between 165 0 and 180 0 center of mass. A 40% polarized neutron beam incident on a liquid hydrogen target was used. The recoil protons were momentum analyzed with a magnetic spectrometer to isolate elastic scatters. A large solid angle carbon polarimeter was used to measure the proton polarization. The measurements are the first at this energy and are in basic agreement with pre-existing phase shift solutions. The proton-carbon analyzing power was measured between 500 and 750 MeV. An empirical fit to the proton-carbon analyzing power between 100 and 750 MeV was done

  10. The spin correlation parameter and analyzing power in n-p elastic scattering at intermediate energies

    International Nuclear Information System (INIS)

    Abegg, R.; Davis, C.A.; Delheij, P.P.J.; Greeniaus, L.G.; Healey, D.C.; Miller, C.A.; Wait, G.D.; Ahmad, M.; Green, P.W.; Lapointe, C.; McDonald, W.J.; Moss, G.A.; Rodning, N.L.; Roy, G.; Ye, Y.

    1989-06-01

    In order to improve existing I=0 phase shift solutions, the spin correlation parameter, A NN , and the analyzing powers, A 0N and A N0 , have been measured in n-p elastic scattering over an angular range of 50 degrees -150 degrees (c.m.) at three neutron energies, 220, 325 and 425 MeV to an absolute accuracy of ±0.03. The data have a profound effect on various phase parameters, particularly the 1 P 1 , 3 D 2 and ε 1 phase parameters which in some cases change by almost a degree. With exception of the highest energy, the data support the predictions of the latest version of the Bonn potential. Also the analyzing power data (A 0N and A N0 ) measured at 477 MeV in a different experiment over a limited angular range (60 degrees - 80 degrees (c.m.)) are reported here. (Author) 30 refs., 10 figs., 5 tabs

  11. Modematic: a fast laser beam analyzing system for high power CO2-laser beams

    Science.gov (United States)

    Olsen, Flemming O.; Ulrich, Dan

    2003-03-01

    The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 describing test methods for laser beam parameters have been approved. To implement these methods in industry is difficult and especially for the infrared laser sources, such as the CO2-laser, the availabl analyzing systems are slow, difficult to apply and having limited reliability due to the nature of the detection methods. In an EUREKA-project the goal was defined to develop a laser beam analyzing system dedicated to high power CO2-lasers, which could fulfill the demands for an entire analyzing system, automating the time consuming pre-alignment and beam conditioning work required before a beam mode analyses, automating the analyzing sequences and data analysis required to determine the laser beam caustics and last but not least to deliver reliable close to real time data to the operator. The results of this project work will be described in this paper. The research project has led to the development of the Modematic laser beam analyzer, which is ready for the market.

  12. Analyzing powers of inelastic dp-scattering in the energy region of delta and roper resonances excitation

    International Nuclear Information System (INIS)

    Malinina, L.V.; Alkhazov, G.D.; Augustyniak, W.

    2001-01-01

    A study of inelastic scattering of polarized 3.73 GeV/c deuterons on protons in the energy region of the Roper N* (1440) and the Δ(1232) resonances excitation has been performed in an exclusive experiment at LNS (Laboratoire National SATURNE, Saclay, France) using the SPES4-π setup. Tensor and vector analyzing powers of pion production for the reactions d+p→d+n+π + , d+p→d+p+π 0 , d+p→d+N+ππ have been measured as functions of the squared deuteron 4-momentum transfer t, of the effective mass of the subsystems (Nπ), (Nππ) and of the pion emission angle. A strong dependence of these analyzing powers upon the pion emission angle is observed. It is found that A yy values for the considered reaction channels are systematically larger than the known inclusive p(d,d')X world data at the nearest beam energy

  13. Low-energy neutron-proton analyzing power and the new Bonn potential and Paris potential predictions

    International Nuclear Information System (INIS)

    Tornow, W.; Howell, C.R.; Roberts, M.L.; Felsher, P.D.; Chen, Z.M.; Walter, R.L.; Mertens, G.; Slaus, I.

    1988-01-01

    Instrumental asymmetries recently observed by Haeberli and co-workers, limit the accuracy of neutron-proton analyzing power A/sub y/(θ) data. These instrumental effects are discussed and calculated for previously published n-p A/sub y/(θ) data at 16.9 MeV. To enable these calculations, the analyzing power for the 2 H(d-arrow-right,n) 3 He reaction was measured at small angles. Additional n-p A/sub y/(θ) data at extreme backward angles, obtained via proton recoil detection, are also reported for this energy in this paper. The composite data set is compared to calculations based on the new Bonn NN potential, the Paris NN potential, and to the recent NN phase-shift solution of Arndt. In addition, a detailed comparison between A/sub y/(θ) calculated from the new Bonn and the Paris potentials between 10 and 50 MeV is shown to reveal unexpectedly large relative differences. The experimental data in this energy range are better described by the Paris potential than by the new Bonn potential

  14. Presenting a model of repair and preventing maintenance of Bushehr nuclear power plants analyzing the data of similar nuclear power plants

    International Nuclear Information System (INIS)

    Parikhan, Hammidreza

    1997-01-01

    Due to the increase application of nuclear energy for producing electricity, special attention must be paid to their maintenance activities in general and preventive maintenance in particular. It has been shown that a well established preventive maintenance programme will enhance the reliability and availability of nuclear power plants. A model of preventive maintenance for Buhehr nuclear power plant which is due to be completed by 2001 is developed. The prescribed model is based on past experiences of VVER nuclear power plants around the world. The utilized data is provided by International Atomic Energy Agency (IAEA) in Vienna, Austria. The data and past experiences reveal such important information as availability, energy loss, types of failures, duration of failure, etc. A strategy for designing a database is established. These data are then analyzed by statistical methods such as Pareto analysis, t-test, K-S test, analysis of variance, etc. The results of our analysis reveal important information in regard to establishment of a well-defined preventive maintenance programme in Buhshehr nuclear power plant. The results show that certain equipment such turbo-generator and control-rods play an important role in the maintenance of a VVER nuclear power plant. Other findings are discussed in great detail

  15. Governance of Aquatic Agricultural Systems: Analyzing Representation, Power, and Accountability

    Directory of Open Access Journals (Sweden)

    Blake D. Ratner

    2013-12-01

    Full Text Available Aquatic agricultural systems in developing countries face increasing competition from multiple stakeholders over rights to access and use natural resources, land, water, wetlands, and fisheries, essential to rural livelihoods. A key implication is the need to strengthen governance to enable equitable decision making amidst competition that spans sectors and scales, building capacities for resilience, and for transformations in institutions that perpetuate poverty. In this paper we provide a simple framework to analyze the governance context for aquatic agricultural system development focused on three dimensions: stakeholder representation, distribution of power, and mechanisms of accountability. Case studies from Cambodia, Bangladesh, Malawi/Mozambique, and Solomon Islands illustrate the application of these concepts to fisheries and aquaculture livelihoods in the broader context of intersectoral and cross-scale governance interactions. Comparing these cases, we demonstrate how assessing governance dimensions yields practical insights into opportunities for transforming the institutions that constrain resilience in local livelihoods.

  16. Angular dependences of the tensor analyzing powers in the dd→3Hen reaction at intermediate energies

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.B.

    2002-01-01

    The tensor analyzing powers A yy , A xx , and A xz in the dd→ 3 Hen reaction at intermediate energies are considered in the framework of the one-nucleon-exchange approximation. Their strong sensitivity to the 3 He and deuteron spin structure at short distances is shown

  17. Configurations of power relations in the Brazilian emergency care system: analyzing a context of visible practices.

    Science.gov (United States)

    Velloso, Isabela; Ceci, Christine; Alves, Marilia

    2013-09-01

    In this paper, we make explicit the changing configurations of power relations that currently characterize the Brazilian Emergency Care System (SAMU) team in Belo Horizonte, Brazil. The SAMU is a recent innovation in Brazilian healthcare service delivery. A qualitative case study methodology was used to explore SAMU's current organizational arrangements, specifically the power relations that have developed and that demonstrate internal team struggles over space and defense of particular occupational interests. The argument advanced in this paper is that these professionals are developing their work in conditions of exposure, that is, they are always being observed by someone, and that such observational exposure provides the conditions whereby everyday emergency care practices are enacted such that practice is shaped by, as well as shapes, particular, yet recognizable power relationships. Data were collected through the observation of the SAMU's work processes and through semi-structured interviews. Research materials were analyzed using discourse analysis. In the emergency care process of work, visibility is actually embedded in the disciplinary context and can thus be analyzed as a technique applied to produce disciplined individuals through the simple mechanisms elaborated by Foucault such as hierarchical surveillance, normalizing judgment, and the examination. © 2012 John Wiley & Sons Ltd.

  18. Analyzing Powers of Inelastic dp-Scattering in the Energy Region of Delta and Roper Resonances Excitation

    CERN Document Server

    Malinina, L V; Augustyniak, W; Boivin, M; Boyard, J L; Dahl, R; Drews, M; Ellegaard, C; Fahri, L; Gaarde, C; Hennino, T; Jourdain, J C; Kagarlis, M A; Kravtsov, A V; Künne, R A; Larsen, J C; Morsch, P; Mylnikov, V A; Orichtchin, E M; Perdrisat, C F; Piskunov, N M; Prokofiev, A N; Punjabi, V; Radvanyi, P; Ramstein, B; Razmyslovich, B V; Roy-Stephan, M; Sitnik, I M; Skousen, M; Strokovsky, E A; Tkach, I I; Tomasi-Gustafsson, E; Volkov, S S; Zhdanov, A A; Zupranski, P

    2001-01-01

    A study of inelastic scattering of polarized 3.73 GeV/c deuterons on protons in the energy region of the Roper N*(1440) and the {DELTA}(1232) resonances excitation has been performed in an exclusive experiment at LNS (Laboratoire National SATURNE, Saclay, France) using the SPES-{pi} setup.Tensor and vector analyzing powers of pion production for the reactions d + p {\\to} d + n + pi^{+}, d + p {\\to} d + p + pi^{0}, d + p {\\to} d + N + pi pi have been measured as functions of the squared deuteron 4-momentum transfer t, of the effective mass of the subsystems (N pi), (N pi pi) and of the pion emission angle. A strong dependence of these analyzing powers upon the pion emission angle is observed. It is found that A_{yy} values for the considered reaction channels are systematically larger than the known inclusive {p (d, d {\\prime}) X} world data at the nearest beam energy.

  19. Extreme values of the analyzing power in dα elastic scattering

    International Nuclear Information System (INIS)

    Jenny, B.; Grueebler, W.; Koenig, V.; Schmelzbach, P.A.

    1985-01-01

    An investigation of states of maximum possible polarization in dα elastic scattering has been carried out between 3 and 43 MeV deuteron energy. Two different types of such maxima were found. In the first type, analyzing power components reach their theoretical maximum values. A second type does not generally yield observables with maximum possible values, but has parameters that lie well within the range allowed. It is particular combination of values that constitutes a state of maximum possible polarization. The search for the two types of maxima was made with the aid of a phase-shift analysis. Several maxima of both kinds were found in the elastic scattering under investigation. The energies and scattering angles for these points have been determined. In most cases a state of maximum polarization indicates a resonant state in the compound system. (orig.)

  20. Analyzing wind turbine directional behavior: SCADA data mining techniques for efficiency and power assessment

    International Nuclear Information System (INIS)

    Castellani, Francesco; Astolfi, Davide; Sdringola, Paolo; Proietti, Stefania; Terzi, Ludovico

    2017-01-01

    Highlights: • The directional behavior of four turbines of an onshore wind farm is investigated. • The positions of the nacelles are discretized to highlight clusterization effects. • The recurrent alignment patterns of the cluster are individuated and analyzed. • The patterns are studied by the point of view of efficiency and power output. • Significative performance deviations arise among the most frequent configurations. - Abstract: SCADA control systems are the keystone for reliable performance optimization of wind farms. Processing into knowledge the amount of information they spread is a challenging task, involving engineering, physics, statistics and computer science skills. This work deals with SCADA data analysis methods for assessing the importance of how wind turbines align in patterns to the wind direction. In particular it deals with the most common collective phenomenon causing clusters of turbines behaving as a whole, rather than as a collection of individuality: wake effects. The approach is based on the discretization of nacelle position measurements and subsequent post-processing through simple statistical methods. A cluster, severely affected by wakes, from an onshore wind farm, is selected as test case. The dominant alignment patterns of the cluster are identified and analyzed by the point of view of power output and efficiency. It is shown that non-trivial alignments with respect to the wind direction arise and important performance deviations occur among the most frequent configurations.

  1. The magnetic field near power lines in the Moscow region: the results of measurements and their analyze

    Directory of Open Access Journals (Sweden)

    Prokofyeva A.S.

    2014-12-01

    Full Text Available The aim: to analyze the real power frequency magnetic field (50 Hz values near power lines. The material. Long-term measurements of the power frequency magnetic field (50 Hz near power lines of 110 kV, 220 kVand 500 kVin the Moscow region. Methods. Measurements were made by tracks which were perpendicular to the wires. Length of tracks was up to 40 m. Sensor of measurer was located on 1.8 m under the ground. General quantity of measurement points were 1103. The results. Was obtained general characteristics of real values of strength of electric field and values of magnetic flux density depending to distance to the projection last wire near power lines. Conclusion. Analysis of the results has the values of the magnetic field of power lines correspond to the Russian rules in all cases. Using additional World Health Organization safety criteria for magnetic fields (the class of carcinogenic risks 2B requires the expansion of the health safety zone 2-3 times.

  2. Measurement of the analyzing power for pion-proton elastic scattering between 471 and 687 MeV/c

    International Nuclear Information System (INIS)

    Mokhtari-Amirmajdi, A.

    1984-01-01

    The analyzing power, A/sub N/, has been measured for π/sup +/-/p → π/sup +/-/p at 471, 547, 625, and 687 MeV/c in an angular range corresponding to -0.9 less than or equal to cos(theta)/sub cm/ less than or equal to 0.8. A polarized proton target with polarization axis normal to the scattering plane was used. The scattered pion and recoil proton were detected in coincidence, using a magnetic spectrometer and a wire chamber/scintillator array, except in cases where one of the particles was kinematically inaccessible. Statistical uncertainties in the data are as low as 0.02; systematic uncertainties are estimated to be less than 5%. The π - p data are characterized by large values of analyzing power, and rapid variations in the angular distribution with incident momentum. The measurements are compared with the results of existing partical wave analysis

  3. FY17 CSSE L2 Milestone Report: Analyzing Power Usage Characteristics of Workloads Running on Trinity.

    Energy Technology Data Exchange (ETDEWEB)

    Pedretti, Kevin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    This report summarizes the work performed as part of a FY17 CSSE L2 milestone to in- vestigate the power usage behavior of ASC workloads running on the ATS-1 Trinity plat- form. Techniques were developed to instrument application code regions of interest using the Power API together with the Kokkos profiling interface and Caliper annotation library. Experiments were performed to understand the power usage behavior of mini-applications and the SNL/ATDM SPARC application running on ATS-1 Trinity Haswell and Knights Landing compute nodes. A taxonomy of power measurement approaches was identified and presented, providing a guide for application developers to follow. Controlled scaling study experiments were performed on up to 2048 nodes of Trinity along with smaller scale ex- periments on Trinity testbed systems. Additionally, power and energy system monitoring information from Trinity was collected and archived for post analysis of "in-the-wild" work- loads. Results were analyzed to assess the sensitivity of the workloads to ATS-1 compute node type (Haswell vs. Knights Landing), CPU frequency control, node-level power capping control, OpenMP configuration, Knights Landing on-package memory configuration, and algorithm/solver configuration. Overall, this milestone lays groundwork for addressing the long-term goal of determining how to best use and operate future ASC platforms to achieve the greatest benefit subject to a constrained power budget.

  4. Analyzing power measurements for the /sup 13/C(p vector,d)/sup 12/C reaction at 200 and 400 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Liljestrand, R P; Cameron, J M; Hutcheon, D A; MacDonald, R; McDonald, W J; Miller, C A; Olsen, W C [Alberta Univ., Edmonton (Canada); Kraushaar, J J; Shepard, J R [Colorado Univ., Boulder (USA). Nuclear Physics Lab.; Rogers, J G [British Columbia Univ., Vancouver (Canada). TRIUMF Facility

    1981-02-26

    Cross sections and analyzing powers for the /sup 13/C(p vector,d) reaction have been measured at 200 and 400 MeV to the O/sup +/, ground state and 2/sup +/, 4.44 MeV state of /sup 12/C. While the cross sections are rather structureless, DWBA calculations in exact finite range account well for both the magnitude and shape of the angular distributions. On the other hand, the measured analyzing powers are in serious disagreement with the DWBA calculations.

  5. Analyzing power measurements for the d+d-d+p+n breakup reaction at 12MeV

    International Nuclear Information System (INIS)

    Felsher, P.D.; Howell, C.R.; Tornow, W.; Roberts, M.L.; Hanly, J.K.; Weisel, G.J.; Ohali, M. Al; Walter, R.L.; Slaus, I.; Lambert, J.M.; Treado, P.A.; Mertens, G.; Fonseca, G.; Soldi, A.; Vlahovic, B.

    1997-01-01

    We report the most extensive set of vector iT11 and tensor T20 and T22 analyzing-power for the d=d-d=p=n reaction. Two-particle coincidence data have been measured for six deuteron-proton, three deuteron-neutron and three proton-neutron angle pairs at an incident deuteron energy of 12.0MeV. These data are compared to impulse-approximation calculations that threat the underlying nucleon-deuteron system exactly and include contributions from both target and projectile breakup processes. This model gives a good description of the analyzing-power and relative cross-section data. We show that the inclusion of nucleon-nucleon P interactions considerably improves the agreement with the spin observables. The disagreement between the data and theoretical predictions show the limitations in our model and the importance of the rescattering processes. We suggest that the d+d three-body breakup process will provide useful information on the nucleon-nucleon force when exact calculations become available. [S0556-2813(97)02907-5

  6. Analyzing power of AGATA triple clusters for gamma-ray linear polarization

    Energy Technology Data Exchange (ETDEWEB)

    Bizzeti, P.G.; Sona, P.; Melon, B.; Bizzeti-Sona, A.M.; Perego, A. [Universita di Firenze, Dipartimento di Fisica, Firenze (Italy); INFN, Firenze (Italy); Michelagnoli, C.; Lunardi, S.; Mengoni, D.; Recchia, F. [INFN, Padova (Italy); Universita di Padova, Dipartimento di Fisica, Padova (Italy); Bazzacco, D.; Farnea, E.; Menegazzo, R.; Ur, C.A. [INFN, Padova (Italy); De Angelis, G.; Gottardo, A.; Napoli, D.R.; Sahin, E.; Valiente-Dobon, J.J. [Laboratori Nazionali di Legnaro, INFN, Padova (Italy); Gadea, A. [University of Valencia, IFIC, CSIC, Valencia (Spain); Nannini, A. [INFN, Firenze (Italy)

    2015-04-01

    We have investigated the ability of AGATA triple clusters to measure the linear polarization of gamma rays, exploiting the azimuthal-angle dependence of the Compton scattering differential cross section. To this aim, partially polarized gamma rays have been produced by Coulomb excitation of the first excited state of {sup 104}Pd and {sup 108}Pd, which decay to the ground state by emission of gamma rays of 555.8 keV and 433.9 keV, respectively. Pulse-shape analysis and gamma-ray tracking techniques have been used to determine the position and time sequence of the interaction points inside the germanium crystals. Anisotropies in the detection efficiency have been taken into account using 661.6 keV gammas from a {sup 137}Cs radioactive source. We obtain an average analyzing power of 0.451(34) at 433.9 keV and 0.484(24) at 555.8 keV. (orig.)

  7. The 20th anniversary of the three-nucleon analyzing power puzzle - a personal recollection

    International Nuclear Information System (INIS)

    Tornow, W. . Author

    2008-01-01

    The history of the three-nucleon analyzing power puzzle is described by an experimentalist who has been collaborating with few-body theoreticians in trying to unravel the physics of this long-standing phenomenon. Although surprising effects have been discovered along the way, the puzzle is still unexplained. Hopefully, some of the long-range three-nucleon force terms predicted by chiral effective field theory in N 3 LO will eventually solve the puzzle. Presented at the 20th Few-Body Conference, Pisa, Italy, 10-14 September 2007. (author)

  8. Monitoring and analyzing features of electrical power quality system performance

    OpenAIRE

    Genci Sharko; Nike Shanku

    2010-01-01

    Power quality is a set of boundaries that allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly with that electric power. Without the proper quality of the power, an electrical device may malfunction, fail prematurely or not operate at all. There are many reasons why the electric power can be of poor quality and many m...

  9. Angular dependences of the tensor analyzing powers in the dd → 3Hen reaction at intermediate energies

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.B.; )

    2002-01-01

    The tensor analyzing powers A yy , A xx , and A xz in the dd → 3 Hen reaction at intermediate energies are considered in the framework of the one-nucleon-exchange approximation. Their strong sensitivity to the 3 He and deuteron spin structure at short distances is shown [ru

  10. Neutron-proton analyzing power data between 7.6 and 18.5 MeV

    International Nuclear Information System (INIS)

    Weisel, G.J.; Tornow, W.; Howell, C.R.; Felsher, P.D.; AlOhali, M.; Chen, Z.P.; Walter, R.L.; Lambert, J.M.; Treado, P.A.; Slaus, I.

    1992-01-01

    Measurements of the analyzing power A y (θ) for neutron-proton scattering have been performed at 7.6, 12.0, 14.1, 16.0, and 18.5 MeV. The experimental setup is described as are the finite-geometry corrections applied to the data. One of these corrections, due to the presence of carbon in the scintillators used for neutron detection, is discussed in detail. The A y (θ) data are compared to the predictions of the Paris and Bonn nucleon-nucleon potentials and the predictions of two phase-shift analyses, one of which incorporates charge-independence breaking effects in the 3 P waves

  11. Analyzing power for the 16O(p,n)16F (4-, 6.37 MeV) reaction at 134 MeV

    International Nuclear Information System (INIS)

    Madey, R.; Fazely, A.; Anderson, B.D.; Baldwin, A.R.; Kalenda, A.M.; McCarthy, R.J.; Tandy, P.C.; Watson, J.W.; Bertozzi, W.; Buti, T.; Finn, M.; Kovash, M.; Pugh, B.; Foster, C.C.

    1982-01-01

    We measured the analyzing power for the 16 O(p,n) 16 F (4 - , 6.37 MeV) reaction at 134.0 MeV and the differential cross section for the same reaction at 135.2 MeV. The shape of the cross section for the transition to this unnatural parity stretched state is described well by a distorted-wave impulse-approximation calculation using a (πd/sub 5/2/, νp/sub 3/2//sup ts-1/) 4 /sub -/ configuration and the effective interaction derived by Love and Franey from nucleon-nucleon phase shifts. The analyzing power from this calculation reproduces all of the qualitative features of the data and supports the use of the impulse approximation as an excellent starting point for describing the reaction mechanism. Quantitative agreement between the experimental and theoretical analyzing power can be improved by eliminating the imaginary tensor term of this interaction and taking the real part to be that derived by Love from the Sussex matrix elements. The sensitivity of the calculations to the choice of optical potentials and the importance of spin-orbit distortion is explored

  12. Analyzing powers and isotope ratios for the natAg(rvec p, intermediate-mass fragment) reaction at 200 MeV

    International Nuclear Information System (INIS)

    Renshaw, E.; Yennello, S.J.; Kwiatkowski, K.; Planeta, R.; Woo, L.W.; Viola, V.E.

    1991-01-01

    Analyzing powers and isotope ratios have been measured for ejectiles with Z≤7 emitted at forward angles in the 200-MeV rvec p+ nat Ag reaction. The observed analyzing powers are consistent with zero, and thus do not provide evidence for a significant contribution from cluster knockout, or similar direct formation mechanisms. Fragment kinetic-energy spectra above the Coulomb peak are compared with a coalescence calculation. The isotopic composition of the elemental kinetic-energy spectra is found to favor N/Z≥1 nuclei for fragment energies near the exit-channel Coulomb energy, whereas species with N/Z≤1 are more abundant in the high-energy spectral tails. This behavior is consistent with the predictions of an accreting source calculation

  13. Neutron-deuteron analyzing power data at 19.0 MeV

    International Nuclear Information System (INIS)

    Weisel, G. J.; Tornow, W.; Crowe, B. J. III; Crowell, A. S.; Esterline, J. H.; Howell, C. R.; Kelley, J. H.; Macri, R. A.; Pedroni, R. S.; Walter, R. L.; Witala, H.

    2010-01-01

    Measurements of neutron-deuteron (n-d) analyzing power A y (θ) at E n =19.0 MeV are reported at 16 angles from θ c.m. =46.7 to 152.0 deg. The objective of the experiment is to better characterize the discrepancies between n-d data and the predictions of three-nucleon calculations for neutron energies above 16.0 MeV. The experiment used a shielded neutron source, which produced polarized neutrons via the 2 H(d-vector,n-vector) 3 He reaction, a deuterated liquid scintillator center detector (CD) and liquid-scintillator neutron side detectors. A coincidence between the CD and the side detectors isolated the elastic-scattering events. The CD pulse height spectrum associated with each side detector was sorted by using pulse-shape discrimination, time-of-flight techniques, and by removing accidental coincidences. A Monte Carlo computer simulation of the experiment accounted for effects due to finite geometry, multiple scattering, and CD edge effects. The resulting high-precision data (with absolute uncertainties ranging from 0.0022 to 0.0132) have a somewhat lower discrepancy with the predictions of three-body calculations, as compared to those found at lower energies.

  14. Scaling behaviour of tensor analyzing power (Ayy) in the inelastic scattering of relativistic deuterons

    International Nuclear Information System (INIS)

    Korovin, P.P.; Malinina, L.V.; Strokovskij, E.A.

    1998-01-01

    We suggest a new dimensionless relativistic invariant variable R Δm X / ν which may be interpreted as the ratio of the excitation energy to the full transferred energy; therefore this variable measures a 'degree of inelasticity' of the scattering. Existing data on the tensor analyzing power of the p(d polarized, d ' )X and 12 C(d polarized, d ' )X inelastic scattering at momenta from 4.2 to 9 GeV/c are analyzed in terms of this variable. We observe that A yy taken as a function of R does not depend upon the incident energy, the scattering angle (up to the angles of θ cm ∼ 30 deg), and there is no noticeable difference between the proton and nuclear targets as well. It is remarkable that A yy is maximal (of ∼ 0.5) when R ∼ 0.5 - 0.6 and is small in absolute value when R is close to its limiting values of 0 and 1

  15. Analyzing power measurements for the rvec d+d→d+p+n breakup reaction at 12 MeV

    International Nuclear Information System (INIS)

    Felsher, P.D.; Howell, C.R.; Tornow, W.; Roberts, M.L.; Hanly, J.M.; Weisel, G.J.; Ohali, M.A.; Walter, R.L.; Slaus, I.; Lambert, J.M.; Treado, P.A.; Mertens, G.; Fonseca, A.C.; Soldi, A.; Vlahovic, B.

    1997-01-01

    We report the most extensive set of vector iT 11 and tensor T 20 and T 22 analyzing-power data for the rvec d+d→d+p+n reaction. Two-particle coincidence data have been measured for six deuteron-proton, three deuteron-neutron and three proton-neutron angle pairs at an incident deuteron energy of 12.0 MeV. These data are compared to impulse-approximation calculations that treat the underlying nucleon-deuteron system exactly and include contributions from both target and projectile breakup processes. This model gives a good description of the analyzing-power and relative cross-section data. We show that the inclusion of nucleon-nucleon P interactions considerably improves the agreement with the spin observables. The disagreement between the data and theoretical predictions show the limitations in our model and the importance of the rescattering processes. We suggest that the d+d three-body breakup process will provide useful information on the nucleon-nucleon force when exact calculations become available. copyright 1997 The American Physical Society

  16. Methods and apparatus of analyzing electrical power grid data

    Science.gov (United States)

    Hafen, Ryan P.; Critchlow, Terence J.; Gibson, Tara D.

    2017-09-05

    Apparatus and methods of processing large-scale data regarding an electrical power grid are described. According to one aspect, a method of processing large-scale data regarding an electrical power grid includes accessing a large-scale data set comprising information regarding an electrical power grid; processing data of the large-scale data set to identify a filter which is configured to remove erroneous data from the large-scale data set; using the filter, removing erroneous data from the large-scale data set; and after the removing, processing data of the large-scale data set to identify an event detector which is configured to identify events of interest in the large-scale data set.

  17. A Monte Carlo approach to the ship-centric Markov decision process for analyzing decisions over converting a containership to LNG power

    NARCIS (Netherlands)

    Kana, A.A.; Harrison, B.M.

    2017-01-01

    A Monte Carlo approach to the ship-centric Markov decision process (SC-MDP) is presented for analyzing whether a container ship should convert to LNG power in the face of evolving Emission Control Area regulations. The SC-MDP model was originally developed as a means to analyze uncertain,

  18. Angular dependences of the tensor analyzing powers in the dd -> sup 3 Hen reaction at intermediate energies

    CERN Document Server

    Ladygin, V P

    2002-01-01

    The tensor analyzing powers A sub y sub y , A sub x sub x , and A sub x sub z in the dd -> sup 3 Hen reaction at intermediate energies are considered in the framework of the one-nucleon-exchange approximation. Their strong sensitivity to the sup 3 He and deuteron spin structure at short distances is shown

  19. A Portable, Low-Power Analyzer and Automated Soil Flux Chamber System for Measuring Wetland GHG Emissions

    Science.gov (United States)

    Nickerson, Nick; Kim-Hak, David; McArthur, Gordon

    2017-04-01

    Preservation and restoration of wetlands has the potential to help sequester large amounts of carbon due to the naturally high primary productivity and slow turnover of stored soil carbon. However, the anoxic environmental conditions present in wetland soils are also the largest natural contributor to global methane emissions. While it is well known that wetlands are net carbon sinks over long time scales, given the high global warming potential of methane, the short-term balances between C uptake and storage and loss as CO2 and CH4 need to be carefully considered when evaluating the climate effects of land-use change. It is relatively difficult to measure methane emissions from wetlands with currently available techniques given the temporally and spatially sporadic nature of the processes involved (methanogenesis, methane oxidation, ebullition, etc.). For example, using manual soil flux chambers can often only capture a portion of either the spatial or temporal variability, and often have other disadvantages associated with soil atmosphere disturbance during deployment in these relatively compressible wetland soils. Automated chamber systems offer the advantage of collecting high-resolution time series of gaseous fluxes while reducing some human and method induced biases. Additionally, new laser-based analyzers that can be used in situ alongside automated chambers offer a greater minimum detectable flux than can be achieved using alternative methods such as Gas Chromatography. Until recently these types of automated measurements were limited to areas that had good power coverage, as laser based systems were power intensive and could not easily be supplemented with power from field-available sources such as solar. Recent advances in laser technology has reduced the power needed and made these systems less power intensive and more field portable in the process. Here we present data using an automated chamber system coupled to a portable laser based greenhouse gas

  20. Improved proton-deuteron phase-shift analysis above the deuteron breakup threshold and the three-nucleon analyzing-power puzzle

    International Nuclear Information System (INIS)

    Tornow, W.; Kievsky, A.; Witala, H.

    2002-01-01

    Using the existing high-accuracy data for proton-deuteron and deuteron-proton elastic scattering, a phase-shift analysis has been performed in the laboratory proton energy range from E p = 4 to 10 MeV The AV 18-based proton-deuteron phase shifts were used as starting values in the phase-shift search procedure. The low-partial wave phase shifts, especially the 4 P j phase shifts have been determined very precisely, thus providing valuable guidance for theoretical approaches to tackle the quest for a successful description of three-nucleon bound-state and continuum observables in a more efficient and consistent way. Furthermore, it was found that the 4 P 1/2 phase shift and the mixing parameter ε 3/2 - determined in the present analysis cannot be generated by 3 P j nucleon-nucleon interactions which are consistent with two-nucleon analyzing power data. Therefore, three-nucleon forces must play an essential role in resolving the long-standing three-nucleon analyzing-power puzzle. Refs. 44 (author)

  1. Analyzing Thermal Module Developments and Trends in High-Power LED

    Directory of Open Access Journals (Sweden)

    Jung-Chang Wang

    2014-01-01

    Full Text Available The solid-state light emitting diode (SSLED has been verified as consumer-electronic products and attracts attention to indoor and outdoor lighting lamp, which has a great benefit in saving energy and environmental protection. However, LED junction temperature will influence the luminous efficiency, spectral color, life cycle, and stability. This study utilizes thermal performance experiments with the illumination-analysis method and window program (vapour chamber thermal module, VCTM V1.0 to investigate and analyze the high-power LED (Hi-LED lighting thermal module, in order to achieve the best solution of the fin parameters under the natural convection. The computing core of the VCTM program employs the theoretical thermal resistance analytical approach with iterative convergence stated in this study to obtain a numerical solution. Results showed that the best geometry of thermal module is 4.4 mm fin thickness, 9.4 mm fin pitch, and 37 mm fin height with the LED junction temperature of 58.8°C. And the experimental thermal resistances are in good agreement with the theoretical thermal resistances; calculating error between measured data and simulation results is no more than ±7%. Thus, the Hi-LED illumination lamp has high life cycle and reliability.

  2. Eddy Covariance Measurements of Methane Flux at Remote Sites with New Low-Power Lightweight Fast Gas Analyzer

    Science.gov (United States)

    Xu, Liukang; Burba, George; Schedlbauer, Jessica; Zona, Donatella; McDermitt, Dayle K.; Anderson, Tyler; Oberbauer, Steven; Oechel, Walter; Komissarov, Anatoly; Riensche, Brad

    2010-05-01

    Majority of natural methane production happens at remote unpopulated areas in ecosystems with little or no infrastructure or easily available grid power, such as arctic and boreal wetlands, tropical mangroves, etc. Present approaches for direct measurements of CH4 fluxes rely on fast closed-path analyzers, which have to work under significantly reduced pressures, and require powerful pumps and grid power. Power and labor demands may be reasons why CH4 flux is often measured at locations with good infrastructure and grid power, and not with high CH4 production. An instrument was developed to allow Eddy Covariance measurements of CH4 flux with power consumption 30-150 times below presently available technologies. This instrument, LI-7700, uses proposed extremely low-power technology would allows placing methane Eddy Covariance stations in the middle of the source (wetland, rice paddy, forest, etc.) in the absence of the grid power. This could significantly expand the Eddy Covariance CH4 flux measurements coverage, and possibly, significantly improve the budget estimates of world CH4 emissions and budget. Various prototypes of the LI-7700 were field-tested for three seasons at the remote site in middle of Everglades National Park (Florida, USA) using solar panels, at three stationary and several mobile sites during three seasons at remote Arctic wetlands near Barrow (Alaska, USA), in the tropical mangroves near La Paz (Mexico) using portable generator, and in bare agricultural field near Mead (Nebraska, USA) during 2005 through 2010. Latest data on CH4 concentration, co-spectra and fluxes, and latest details of instrumental design are examined in this presentation. Overall, hourly methane fluxes ranged from near-zero at night to about 4 mg m-2 h-1 in midday in arctic tundra. Observed fluxes were within the ranges reported in the literature for a number of wetlands in North America, including the Everglades wetlands. Diurnal patterns were similar to those measured by

  3. Analyzing power of inclusive production of π+,π-, and KS0 by polarized protons at 13.3 and 18.5 GeV/c

    International Nuclear Information System (INIS)

    Bonner, B.E.; Buchanan, J.A.; Clement, J.M.; Corcoran, M.D.; Krishna, N.M.; Kruk, J.W.; Miettinen, H.E.; Moss, R.M.; Mutchler, G.S.; Nessi-Tedaldi, F.; Nessi, M.; Phillips, G.C.; Roberts, J.B.; Stevenson, P.M.; Tonse, S.R.; Birman, A.; Chung, S.U.; Etkin, A.; Fernow, R.C.; Kirk, H.; Protopopescu, S.D.; Willutzki, H.; Hallman, T.; Madansky, L.; Bar-Yam, Z.; Dowd, J.; Kern, W.; King, E.; Mayes, B.W.; Pinsky, L.S.

    1990-01-01

    We have measured the analyzing power in π + , π - , and K S 0 production by a polarized proton beam at 13.3 and 18.5 GeV/c. The data cover the central and the beam fragmentation region, in the transverse-momentum range up to 2 GeV/c. The results indicate that sizable effects are present at high x F and also persist into the hard-scattering region for K S 0 and π + . A zero value of the analyzing power was observed for π - production

  4. Cross sections and analyzing powers of 15N(p,n)15O at 200 MeV and 494 MeV

    International Nuclear Information System (INIS)

    Ciskowski, D.E.

    1989-11-01

    Differential cross sections and analyzing powers have been measured for the 15 N(p,n) 15 O(g.s.) reaction at bombarding energies of 200 MeV and 494 MeV. The 494 MeV data were obtained at the LAMPF Neutron Time-Of-Flight Facility on an 82 m flight path with a resolution of about 2.7 MeV. The 200 MeV data were obtained at IUCF on a 76m flight path with a resolution of about 1.1 MeV. At both energies, the measured analyzing power is small, the magnitude is less than .2 for momentum transfers of less than 1 fm -1 . In contrast, both Relativistic and standard DWIA calculations predict a maximum of A=-.7 near q=0.7 fm -1 . 53 refs., 44 figs

  5. A conceptual framework to analyze and mitigate aging effects of a system in nuclear power plants

    International Nuclear Information System (INIS)

    Ahmed, S.

    1985-01-01

    A conceptual framework is developed to analyze, characterize, and mitigate the degradation of a system in a nuclear power plant due to aging. The system is evaluated, based on an aging-specific system decision model, to understand and implement decisions pertaining to surveillance, maintenance, and replacement. Decisions on other corrective measures to mitigate the effects of aging of a number of equipment items, interconnections (relationships with other systems), and interfaces (relationships within the system) can also be made based on the proposed approach

  6. Neutron-proton analyzing power at 12 MeV and inconsistencies in parametrizations of nucleon-nucleon data

    OpenAIRE

    Braun, R. T.; Tornow, W.; Howell, C. R.; Trotter, D. E. Gonzalez; Roper, C. D.; Salinas, F.; Setze, H. R.; Walter, R. L.; Weisel, G. J.

    2008-01-01

    We present the most accurate and complete data set for the analyzing power Ay(theta) in neutron-proton scattering. The experimental data were corrected for the effects of multiple scattering, both in the center detector and in the neutron detectors. The final data at En = 12.0 MeV deviate considerably from the predictions of nucleon-nucleon phase-shift analyses and potential models. The impact of the new data on the value of the charged pion-nucleon coupling constant is discussed in a model s...

  7. Neutron-proton analyzing power at 12 MeV and inconsistencies in parametrizations of nucleon-nucleon data

    International Nuclear Information System (INIS)

    Braun, R.T.; Tornow, W.; Howell, C.R.; Gonzalez Trotter, D.E.; Roper, C.D.; Salinas, F.; Setze, H.R.; Walter, R.L.; Weisel, G.J.

    2008-01-01

    We present the most accurate and complete data set for the analyzing power A y (θ) in neutron-proton scattering. The experimental data were corrected for the effects of multiple scattering, both in the center detector and in the neutron detectors. The final data at E n =12.0 MeV deviate considerably from the predictions of nucleon-nucleon phase-shift analyses and potential models. The impact of the new data on the value of the charged pion-nucleon coupling constant is discussed in a model study

  8. Analyzing-power measurements of Coulomb-nuclear interference with the polarized-proton and -antiproton beams at 185 GeV/c

    Energy Technology Data Exchange (ETDEWEB)

    Akchurin, N; Onel, Y [Iowa Univ., Iowa City, IA (USA). Dept. of Physics; Carey, D; Coleman, R; Cossairt, J D; Read, A L [Fermi National Accelerator Lab., Batavia, IL (USA); Corcoran, M D; Nessi-Tedaldi, F; Nessi, M; Nguyen, C; Phillips, G C; Roberts, J B; White, J L [Rice Univ., Houston, TX (USA). Bonner Nuclear Labs.; Derevschikov, A; Matulenko, Yu A; Meschanin, A P; Nurushev, S B; Solovyanov, V L; Vasiliev, A N [Institut Fiziki Vysokikh Ehnergij, Serpukhov (USSR); Gazzaly, M M [Minnesota Univ., Minneapolis (USA). Dept. of Physics; Grosnick, D P; Hill, D; Laghai, M; Lopiano, D; Ohashi, Y; Shima, T; Spinka, H; Stanek, R W; Underwood, D G; Yokosawa, A [Argonne National Lab., IL (USA); Imai, K; Makino, S; Masaike, A; Miyake, K; Nagamine, T; Takeutchi, F; Tamura, N; Yoshida, T [Kyoto Univ. (Japan); Kuroda, K; Michalowicz, A [Institut National de Physique Nucleaire et de Physique des Particules, 74 - Annecy-le-Vieux (France). Lab. de P; E-581/704 Collaboration

    1989-10-12

    The analyzing power A{sub N} of proton-proton, proton-hydrocarbon, and antiproton-hydrocarbon scattering in the Coulomb-nuclear interference region has been measured using the 185 GeV/c Fermilab polarized-proton and -antiproton beams. The results are found to be consistent with theoretical predictions within statistical uncertainties. (orig.).

  9. Neutron-proton analyzing power at 12 MeV and inconsistencies in parametrizations of nucleon-nucleon data

    Energy Technology Data Exchange (ETDEWEB)

    Braun, R.T. [Department of Physics, Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Department of Physics, Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)], E-mail: tornow@tunl.duke.edu; Howell, C.R.; Gonzalez Trotter, D.E.; Roper, C.D.; Salinas, F.; Setze, H.R.; Walter, R.L. [Department of Physics, Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Weisel, G.J. [Department of Physics, Penn State Altoona, Altoona, PA 16601 (United States)

    2008-02-21

    We present the most accurate and complete data set for the analyzing power A{sub y}({theta}) in neutron-proton scattering. The experimental data were corrected for the effects of multiple scattering, both in the center detector and in the neutron detectors. The final data at E{sub n}=12.0 MeV deviate considerably from the predictions of nucleon-nucleon phase-shift analyses and potential models. The impact of the new data on the value of the charged pion-nucleon coupling constant is discussed in a model study.

  10. Development of remote controlled electron probe micro analyzer with crystal orientation analyzer

    International Nuclear Information System (INIS)

    Honda, Junichi; Matsui, Hiroki; Harada, Akio; Obata, Hiroki; Tomita, Takeshi

    2012-07-01

    The advanced utilization of Light Water Reactor (LWR) fuel is progressed in Japan to save the power generating cost and the volume of nuclear wastes. The electric power companies have continued the approach to the burnup extension and to rise up the thermal power increase of the commercial fuel. The government should be accumulating the detailed information on the newest technologies to make the regulations and guidelines for the safety of the advanced nuclear fuels. The remote controlled Electron Probe Micro Analyzer (EPMA) attached with crystal orientation analyzer has been developed in Japan Atomic Energy Agency (JAEA) to study the fuel behavior of the high burnup fuels under the accident condition. The effects of the cladding microstructure on the fuel behavior will be evaluated more conveniently and quantitatively by this EPMA. The commercial model of EPMA has been modified to have the performance of airtight and earthquake resistant in compliance with the safety regulation by the government for handling the high radioactive elements. This paper describes the specifications of EPMA which were specialised for post irradiation examination and the test results of the cold mock-up to confirm their performances and reliabilities. (author)

  11. An integrated simulation tool for analyzing the Operation and Interdependency of Natural Gas and Electric Power Systems

    OpenAIRE

    PAMBOUR Kwabena A.; CAKIR BURCIN; BOLADO LAVIN Ricardo; DIJKEMA Gerard

    2016-01-01

    In this paper, we present an integrated simulation tool for analyzing the interdependency of natural gas and electric power systems in terms of security of energy supply. In the first part, we develop mathematical models for the individual systems. In part two, we identify the interconnections between both systems and propose a method for coupling the combined simulation model. Next, we develop the algorithm for solving the combined system and integrate this algorithm into a simulation softwa...

  12. Automatic analyzer of the coefficient of excess air and products of chemical under firing of heat and power engineering installations

    Energy Technology Data Exchange (ETDEWEB)

    Babushkin, V V; Furman, N I; Shcherban, A N; Tarasevich, V N

    1981-01-01

    A sensor of the combustion quality of gas and oil fuel in boiler furnaces which is intended to be used for automatic measurement of an excess amount of 0/sub 2/ and fuel components, and also of associated elements present in a stoichiometric ratio of 0/sub 2/ and fuel components in the waste gasses is proposed. The AST-2 fuel combustion analyzer is developed based on this sensor. It consists of a sample preparation unit of the controlled environment and a power source. The sample preparation unit is determined by the structural engineering specifics of the power unit in which the fuel combustion controlled process is carried out. The sample preparation unit, which is made for 11 open-hearth ovens of ''Azovstal''' factory, is intended for drying and purging of mechanical and aggressive impurities the samples of the gas to be analyzed and additional reagents, and also for controlling and monitoring constancy and amount of pressure, temperature, and humidity.

  13. Analyzing powers and interference between one- and multi-step processes in (polarized p, t) reactions on medium-mass vibrational nuclei

    International Nuclear Information System (INIS)

    Yagi, K.; Kunori, S.; Aoki, Y.; Nagano, K.; Tagishi, Y.

    1978-01-01

    A neutron-number (N) dependence of analyzing powers A (theta) has been observed for the first time in (polarized p, t) reactions leading to the quadrupole vibrational states (2 1 + ) in 98 Ru, sup(102,108)Pd, 114 Cd, 116 Sn, and sup(120,126)Te. Although analyzing powers for the ground-state transitions A(theta,0 sub(g)sup(+)) are very similar to each other, those for the 2 1 + transitions A(theta,2 1 + ) for the nuclei belonging to the beginning of the N = 50 - 82 shell are markedly different, having almost opposite signs, from A(theta,2 1 + ) for nuclei belonging to the latter half of the major shell. The difference is explained as a result of a sign change of the interference between one- and inelastic multi-step processes in two-neutron pickup reactions. Nuclear structure effects on such an interference are discussed on the basis of the microscopic description of collective quadrupole oscillation of nuclei. (author)

  14. Computer-based radionuclide analyzer system

    International Nuclear Information System (INIS)

    Ohba, Kengo; Ishizuka, Akira; Kobayashi, Akira; Ohhashi, Hideaki; Tsuruoka, Kimitoshi.

    1978-01-01

    The radionuclide analysis in nuclear power plants, practiced for the purpose of monitoring the quality of the primary loop water, the confirmation of the performance of reactor cleanup system and monitoring the radioactive waste effluent, is an important job. Important as it is, it requires considerable labor of experts, because the samples to be analyzed are multifarious and very large in number, and in addition, this job depends much on manual work. With a view of saving the labor, simplifying and standardizing the work, reducing radiation exposure, and automatizing the work of analysis, the computerized analyzer system has been worked out. The results of its performance test at the operating power plant have proved that the development has fairly accomplished the objects and that the system is well useful. The developmental work was carried out by the cooperation between The Tokyo Electric Power Co. and Toshiba in about 4 years from 1974 to this year. (auth.)

  15. Analyzing power of polarized protons interactions with carbon nuclei at 0.71-3.61 GeV

    International Nuclear Information System (INIS)

    Anoshina, E.V.; Bodyagin, V.A.; Vardanyan, I.N.; Gribushin, A.M.; Ershov, A.A.; Kruglov, N.A.; Sarycheva, L.I.

    1997-01-01

    For the first time at JINR synchrophasotron an experiment in the polarized proton beam was carried out. Beams of polarized protons with energy T p = 0.71-3.61 GeV, polarization P p ≅ 0.5 and intensity I p ≅ 10 6 particles/spell have been formed, their characteristics were investigated, and a possibility to use those beams as initial for physical and methodical investigations has been shown. The proton-carbon interaction analyzing power at the energies of 1.46 and 3.61 GeV has been measured for two values of the scattering angle. 22 refs., 3 figs

  16. Determination of proton-nucleon analyzing powers and spin-rotation-depolarization parameters at 500 MeV

    International Nuclear Information System (INIS)

    Marshall, J.A.; Barlett, M.L.; Fergerson, R.W.; Hoffmann, G.W.; Milner, E.C.; Ray, L.; Amann, J.F.; Bonner, B.E.; McClelland, J.B.

    1986-01-01

    500 MeV p-arrow-right+p elastic and quasielastic, and p-arrow-right+n quasielastic, analyzing powers (A/sub y/) and spin-rotation-depolarization parameters (D/sub S//sub S/, D/sub S//sub L/, D/sub L//sub S/, D/sub L//sub L/, D/sub N//sub N/) were determined for center-of-momentum angular ranges 6.8 0 -55.4 0 (elastic) and 22.4 0 -55.4 0 (quasielastic); liquid hydrogen and deuterium targets were used. The p-arrow-right+p elastic and quasielastic results are in good agreement; both the p-arrow-right+p and p-arrow-right+n parameters are well described by current phase shift solutions

  17. Fuel-Cell-Powered Electric Motor Drive Analyzed for a Large Airplane

    Science.gov (United States)

    Brown, Gerald V.; Choi, Benjamin B.

    2005-01-01

    Because of its high efficiency, fuel cell technology may be used to launch a new generation of more-electric aeropropulsion and power systems for future aircraft. Electric-motor-driven airplanes using fuel-cell powerplants would be beneficial to the environment because of fuel savings, low noise, and zero carbon-dioxide emissions. In spite of the fuel cell s efficiency benefit, to produce the same shaft drive power, a fuel cell- powered electric-drive system must be definitely heavier than a turbine-drive system. However, the fuel-cell system s overall efficiency from fuel-to-shaft power is higher than for a turbine-drive system. This means that the fuel consumption rate could be lower than for a conventional system. For heavier, fuel-laden planes for longer flights, we might achieve substantial fuel savings. In the airplane industry, in fact, an efficiency gain of even a few percentage points can make a major economic difference in operating costs.

  18. Analyzing power for π-p elastic scattering in the energy region of the Roper resonance

    International Nuclear Information System (INIS)

    Mokhtari, A.; Briscoe, W.J.; Eichon, A.D.; Fitzgerald, D.H.; Kim, G.J.; Nefkens, B.M.K.; Wightman, J.A.; Sadler, M.E.

    1986-01-01

    High-precision measurements of the analyzing power A/sub N/ in π - p elastic scattering at p/sub π/ = 471--687 MeV/c are presented and compared with the results of recent πN partial-wave analyses (PWA's) by the Karlsruhe-Helsinki, CMU-LBL, and VPI groups. While agreeing with the main features of the measured angular dependence of A/sub N/, the three PWA's yield larger values than the measurements at forward angles at p/sub π/ = 471, 547, and 625 MeV/c. At 687 MeV/c the PWA's do not agree with the data at far backward angles. We estimate the effect of our data on the phase shifts in this energy region, which includes the Roper resonance

  19. Analyzing the effect of dynamic loads on economic dispatch in the presence of interline power flow controller using modified BAT algorithm

    Directory of Open Access Journals (Sweden)

    Y.N. Vijay Kumar

    2016-05-01

    Full Text Available Now a day, non-uniform increase of demand on a power system turns the research toward the dynamic analysis. In this paper, to perform dynamic analysis and to solve economic load dispatch problem using optimal power flow (OPF, four realistic load levels are considered. Further, the effectiveness of the objective has been enhanced in the presence of interline power flow controller (IPFC. An optimal location identification methodology for IPFC based on line stability index (LSI is also presented. The effect of ramp-rate limits on generations and the effect of dynamic loads on generation fuel cost and transmission losses are also analyzed on standard IEEE-30 bus and real time 23 bus test systems with supporting validations, numerical and graphical results.

  20. Preparation of Input Deck to analyze the Nuclear Power Plant for the Use of Regulatory Verification

    International Nuclear Information System (INIS)

    Kang, Doo Hyuk; Kim, Hyung Seok; Suh, Jae Seung; Ahn, Seung Hoon

    2009-01-01

    The objectives of this paper are to make out the input deck that analyzes a nuclear power plant for the use of regulatory verification and to produce its calculation note. We have been maintained the input deck of T/H safety codes used in existing domestic reactors to ensure independent and accurate regulatory verification for the thermal-hydraulic safety analysis in domestic NPPs. This paper is mainly divided into two steps: first step is to compare existing input deck to the calculation note in order to verify the consistency. Next step is to model 3-dimensional reactor pressure vessel using MULTID component instead of the 1D existing input deck

  1. Proposal on the measurements of d-p elastic scattering analyzing powers at 0.3-2.0 GeV at internal target station of the Nuclotron

    International Nuclear Information System (INIS)

    Uesaka, T.; Ladygin, V.P.; Azhgirej, L.S.

    2005-01-01

    A new high-energy beam polarimeter is proposed for the Nuclotron using Internal Target Station. This polarimeter based on the measurement of the asymmetry for the d-p elastic scattering will allow one to measure both vector and tensor components of the deuteron beam polarization simultaneously. For that purpose the measurement of analyzing powers for the d-p elastic scattering at energies T d = 0.88-2 GeV is proposed. The precise measurements of the deuteron analyzing powers over energy range T d 300-2000 MeV can give an irreplaceable clue on the study of spin-dependence of three-nucleon forces

  2. Vector analyzing power and cross section for the reactions 40Ar(d(pol),p)41Ar and 40Ar(d(pol),t)39Ar

    International Nuclear Information System (INIS)

    Sen, S.; Darden, S.E.; Yoh, W.A.; Berners, E.D.

    1975-01-01

    Angular distributions of vector analyzing power and cross section for the reactions 40 Ar(d,p) 41 Ar and 40 Ar(d,t) 39 Ar have been measured at an incident deuteron energy of 14.83 MeV. The bound-state data in the (d,p) reaction and the (d,t) data are compared to DWBA calculations. The data for the neutron-unbound states are analyzed in the framework of the DWBA using (i) a form factor for weakly bound neutron and (ii) a resonance form factor, following the approach of Vincent and Fortune. The j-dependence of the (d,p) vector analyzing power permits definite spin-parity assignments to be made for 19 neutron-bound and 4 neutron unbound states in 41 Ar with excitation energy up to 6.57 MeV. Tentative Jsup(π) assignments have been made for 3 states. The l-value for the 5.62 MeV states has been determined. Data for the observed unbound states are found to be equally well reproduced by the type (i) calculations as by the type (ii) calculations. The (d,t) vector cnalyzing power data show definite J-dependence although not as strongly as in the (d,p) reaction. For relatively weakly excited states a pre-knowledge of the l-value of the transition is desirable for an unambiguous spin assignment. In general, the J-dependence in the (d,t) vector analyzing power can be utilized for definitive Jsup(π) assignments. On this basis, Jsub(π) values have been assigned for seven states in 39 Ar with excitation energies up to 4.47MeV excitation. Possible spin values for three other states are suggested. Spectroscopic factors fo the states in 41 Ar and 39 Ar have been extracted and are in fair agreement with those obtained by other workers. (Auth.)

  3. Complete Set of Deuteron Analyzing Powers for dp Elastic Scattering at 250 MeV/nucleon and Three Nucleon Forces

    Directory of Open Access Journals (Sweden)

    Shimizu Y.

    2010-04-01

    Full Text Available Measurements of a complete set of deuteron analyzing powers (iT11, T20, T21, T22 for elastic deuteron–proton scattering at 250 MeV/nucleon have been performed with polarized deuteron beams at RIKEN RI Beam Factory. The obtained data are compared with the Faddeev calculations based on the modern nucleon–nucleon forces together with the Tucson-Melbourne’99, and UrbanaIX three nucleon forces.

  4. Making the Spoon: Analyzing and Employing Stability Power in Counterinsurgency Operations

    Science.gov (United States)

    2007-05-11

    GWOT then organizations that are best suited to 115On a Maslow’s Scale of Physiological, Safety, Love, Esteem , and Self Actualization essential services...Economic Effects of 9/11:A Retrospective Assessment. Report to Congress: Specialist in Economic Policy, 2002. Maslow , Abraham H., and Robert Frager...Stability Power: The Requirement of Self Securing Elements of National Introducing Stability Power

  5. Analyzing Power of 3He(n, n)3He Between 1.60 and 5.54 MeV

    International Nuclear Information System (INIS)

    Esterline, J.; Tornow, W.

    2013-01-01

    We report the measurements of the analyzing power A y (θ) of n- 3 He elastic scattering with unprecedented accuracy and angular coverage at five incident neutron energies between 1.60 and 5.54 MeV. To this end, we employed the polarization-transfer reactions 3 H(p, n) 3 He and 2 H(d, n) 3 He at 0 ° for neutron generation and a recently developed high-pressure 3 He gas scintillator as an active target, enabling neutron-time-of-flight and 3 He recoil-energy determinations. We obtained simultaneously the neutron polarization with a 4 He-based polarimeter, capitalizing on the well-known n- 4 He A y (θ). Our n- 3 He A y (θ) data are compared to rigorous four-nucleon calculations using high-precision nucleon–nucleon potential models. The agreement between data and calculations is fair at the lower energies and becomes less satisfactory with increasing neutron energy. However, in comparison to the pure isotriplet p- 3 He system in the same energy region, the agreement between measured and calculated A y is much better for the mixed (isotriplet and isosinglet) n- 3 He system, indicating large and somewhat counterintuitive isospin effects. We note that the incorporation of a Δ-mediated three-nucleon force in calculations of n- 3 He scattering was found to affect A y (θ) negligibly, suggesting the need for the reconsideration of fundamental interactions in resolving the four-nucleon analyzing power puzzle first established about a decade ago in p- 3 He scattering. (author)

  6. Diagnosis of power generator sets by analyzing the crank shaft angular speed

    International Nuclear Information System (INIS)

    Desbazeille, M.

    2010-07-01

    This thesis deals with the diagnosis of a powerful 20-cylinder diesel engine which runs a generator set in a nuclear plant. The objective is to make a diagnosis by analyzing the crank shaft angular speed variations. Only combustion related faults are investigated. As the engine is very large, the first crank shaft natural modes are in the low frequencies. Torsional vibrations of the flexible crank shaft strongly complicate the analysis of the angular speed variations. Little attention has been paid to such large engines in the literature. First, a dynamical model with the assumption of a flexible crank shaft is established. The parameters of the model are optimized with the help of actual data. Then, an original automated diagnosis based on pattern recognition of the angular speed waveforms is proposed. Indeed, any faulty cylinder in combustion stroke will distort the angular speed waveform in a specific way which depends on its location with respect to nodes and anti-nodes of the modes. Reference patterns, representative of the engine conditions, are computed with the model constituting the main originality of this work. Promising results are obtained in operational phase. An experimental fuel leakage fault was correctly diagnosed, including detection and localization of the faulty cylinder and an indication of the severity of the fault. (author)

  7. Development of the Chinshan plant analyzer and its assessment with plant data

    International Nuclear Information System (INIS)

    Shihjen Wang; Chunsheng Chien; Jungyuh Jang; Shawcuang Lee

    1993-01-01

    To apply fast and accurate simulation techniques to Taiwanese nuclear power plants, plant analyzer technology was transferred to Taiwan from the Brookhaven National Laboratory (BNL) through a cooperative program. The Chinshan plant analyzer is developed on the AD100 peripheral processor systems, based on the BNL boiling water reactor plant analyzer. The BNL plant analyzer was first converted from MPS10 programming for AD10 to ADSIM programming for AD100. It was then modified for the Taiwan Power Company's Chinshan power station. The simulation speed of the Chinshan plant analyzer is eight times faster than real time. A load rejection transient performed at 100% of full power during startup tests was simulated with the Chinshan plant analyzer, and the results were benchmarked against test data. The comparison shows good agreement between calculated results and test data

  8. Analyzing power for π-p charge exchange and a test of isospin invariance up to eta threshold

    International Nuclear Information System (INIS)

    Wightman, J.A.; Eichon, A.D.; Kim, G.J.; Mokhtari, A.; Nefkens, B.M.K.; Fitzgerald, D.H.; Sadler, M.E.

    1987-01-01

    The analyzing power for π - p→π 0 n has been measured at five incident momenta from 547 to 687 MeV/c using a transversely polarized target. Data were obtained with scintillation counters at 10 angles simultaneously covering the range -0.9 ≤ cosθ/sub c.m.//sup π/ ≤ 0.9. Our results and those of Kim et al. are used for a model-independent test of isospin invariance which is based on the triangle inequalities applied to the transversity-up as well as the transversity-down cross sections. No evidence is found for isospin violation

  9. Development of pulse neutron coal analyzer

    International Nuclear Information System (INIS)

    Jing Shiwie; Gu Deshan; Qiao Shuang; Liu Yuren; Liu Linmao; Jing Shiwei

    2005-01-01

    This article introduced the development of pulsed neutron coal analyzer by pulse fast-thermal neutron analysis technology in the Radiation Technology Institute of Northeast Normal University. The 14 MeV pulse neutron generator and bismuth germanate detector and 4096 multichannel analyzer were applied in this system. The multiple linear regression method employed to process data solved the interferential problem of multiple elements. The prototype (model MZ-MKFY) had been applied in Changshan and Jilin power plant for about a year. The results of measuring the main parameters of coal such as low caloric power, whole total water, ash content, volatile content, and sulfur content, with precision acceptable to the coal industry, are presented

  10. Proton-proton elastic scattering excitation functions at intermediate energies: Cross sections and analyzing powers

    CERN Document Server

    Hinterberger, F; Altmeier, M; Bauer, F; Bisplinghoff, J; Büsser, K; Busch, M; Colberg, T; Diehl, O; Dohrmann, F; Engelhardt, H P; Eversheim, P D; Felden, O; Gebel, R; Glende, M; Greiff, J; Gross-Hardt, R; Hinterberger, F; Jahn, R; Jonas, E; Krause, H; Langkau, R; Lindemann, T; Lindlein, J; Maier, R; Maschuw, R; Mayer-Kuckuk, T; Meinerzhagen, A; Naehle, O; Prasuhn, D; Rohdjess, H; Rosendaal, D; Von Rossen, P; Schirm, N; Schulz-Rojahn, M; Schwarz, V; Scobel, W; Trelle, H J; Weise, E; Wellinghausen, A; Woller, K; Ziegler, R

    2000-01-01

    The EDDA experiment at the cooler synchrotron COSY measures proton-proton elastic scattering excitation functions in the momentum range 0.8 - 3.4 GeV/c. In phase 1 of the experiment, spin-averaged differential cross sections were measured continuously during acceleration with an internal polypropylene (CH sub 2) fiber target, taking particular care to monitor luminosity as a function of beam momentum. In phase 2, excitation functions of the analyzing power A sub N and the polarization correlation parameters A sub N sub N , A sub S sub S and A sub S sub L are measured using a polarized proton beam and a polarized atomic hydrogen beam target. The paper presents recent d sigma/d OMEGA and A sub N data. The results provide excitation functions and angular distributions of high precision and internal consistency. No evidence for narrow structures was found. The data are compared to recent phase shift solutions.

  11. Measurement of the tensor analyzing powers in the dd→3Hen and dd→3Hp reactions at RIKEN

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.B; Sakai, H.; Uesaka, T.

    2000-01-01

    A new experiment is proposed to measure the angular distribution of the tensor analyzing powers A yy , A xx , and A xz in the dd→ 3 Hen and dd→ 3 Hp reactions using polarized deuteron beam at RIKEN. These polarization observables are sensitive to the spin-momentum distribution of neutron (proton) in 3 He( 3 H) at short distances in the framework of one-nucleon exchange approximation. These measurements will provide new insight into the 3-nucleon system spin structure at distances unreachable at the moment using electromagnetic probes

  12. Analyzing power Ay(θ) of n-3He elastic scattering between 1.60 and 5.54 MeV.

    Science.gov (United States)

    Esterline, J; Tornow, W; Deltuva, A; Fonseca, A C

    2013-04-12

    Comprehensive and high-accuracy n-3He elastic scattering analyzing power Ay(θ) angular distributions were obtained at five incident neutron energies between 1.60 and 5.54 MeV. The data are compared to rigorous four-nucleon calculations using high-precision nucleon-nucleon potential models; three-nucleon force effects are found to be very small. The agreement between data and calculations is fair at the lower energies and becomes less satisfactory with increasing neutron energy. Comparison to p-3He scattering over the same energy range exhibits unexpectedly large isospin effects.

  13. Feminized Power and Adversarial Advocacy: Levelling Arguments or Analyzing Them?

    Science.gov (United States)

    Condit, Celeste Michelle

    1989-01-01

    Examines the journalistic analysis of the 1988 Presidential Debates from a feminist perspective in order to identify the revisions needed in the debate process. Provides historical background of feminized power and adversarial advocacy. (MM)

  14. Use of a field model to analyze probable fire environments encountered within the complex geometries of nuclear power plants

    International Nuclear Information System (INIS)

    Boccio, J.L.; Usher, J.L.; Singhal, A.K.; Tam, L.T.

    1985-08-01

    A fire in a nuclear power plant (NPP) can damage equipment needed to safely operate the plant and thereby either directly cause an accident or else reduce the plant's margin of safety. The development of a field-model fire code to analyze the probable fire environments encountered within NPP is discussed. A set of fire tests carried out under the aegis of the US Nuclear Regulatory Commission (NRC) is described. The results of these tests are then utilized to validate the field model

  15. 21 CFR 870.3640 - Indirect pacemaker generator function analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...

  16. Measurement of Analyzing Powers for the Reaction \\vec{p}+CH_2 at p_p = 1.75-5.3 GeV/c

    CERN Document Server

    Azhgirey, L S; Basilev, S N; Bushuev, Yu P; Glagolev, V V; Kirillov, D A; Korovin, P P; Manyakov, P K; Piskunov, N M; Sitnik, I M; Slepnev, V M; Muvsinsky, J; Tomasi-Gustafsson, E; Pentchev, L; Perdrisat, C F; Punjabi, V; Jones, M K; Kumbartzki, G F; Atanasov, I

    2004-01-01

    We report a new measurement of analyzing powers for the reaction \\vec{p}+CH_2\\to one charged particle+X at proton momenta of 1.75, 3.8, 4.5 and 5.3 GeV/c. These results extend the existing data basis, necessary for proton polarimetry at intermediate energy, and confirm the feasibility of a large acceptance polarimeter based on this process.

  17. Dionex series 8000 on-line analyzer, Sequoyah Nuclear Power Plant. Final report

    International Nuclear Information System (INIS)

    1986-03-01

    This project was initiated to develop a custom-designed online water analyzer (ion chromatograph) for secondary water chemistry control in TVA's nuclear plants. This water analyzer development was conducted pursuant to a cooperative research agreement with the Dionex Corporation. Dionex developed and installed a dual channel, six stream analyzer on the secondary side of TVA's Sequoyah Nuclear Plant. The analyzer was developed for real time detection of sodium, chloride, and sulfate in any of the six sampling streams. The analyzer is providing Sequoyah's plant personnel with reliable secondary water chemistry data in a much more timely manner than the past grab sampling techniques. Results on the performance of the analyzer show that it is performing above and beyond the expectations of plant personnel. Since its installation at Sequoyah, there have been 29 units ordered from Dionex including 1 unit for Sequoyah, 5 units for Browns Ferry, and 23 units for other utilities. In the future, the analyzer will allow plant staffs to take corrective action before corrosive conditions occur or before having to derate a unit

  18. Review of Power System Stability with High Wind Power Penetration

    DEFF Research Database (Denmark)

    Hu, Rui; Hu, Weihao; Chen, Zhe

    2015-01-01

    analyzing methods and stability improvement approaches. With increasing wind power penetration, system balancing and the reduced inertia may cause a big threaten for stable operation of power systems. To mitigate or eliminate the wind impacts for high wind penetration systems, although the practical......This paper presents an overview of researches on power system stability with high wind power penetration including analyzing methods and improvement approaches. Power system stability issues can be classified diversely according to different considerations. Each classified issue has special...... and reliable choices currently are the strong outside connections or sufficient reserve capacity constructions, many novel theories and approaches are invented to investigate the stability issues, looking forward to an extra-high penetration or totally renewable resource based power systems. These analyzing...

  19. Techniques for vector analyzing power measurements of the 2H(n vector,np)n breakup reaction at low energies

    International Nuclear Information System (INIS)

    Howell, C.R.; Tornow, W.; Pfuetzner, H.G.; Li Anli; Roberts, M.L.; Murphy, K.; Felsher, P.D.; Weisel, G.J.; Naqvi, A.; Walter, R.L.; Lambert, J.M.; Treado, P.A.

    1990-01-01

    Experimental methods to measure the vector analyzing powers over a broad range of kinematic configurations in the n-d breakup reaction have been developed at TUNL. These techniques employ the polarized beam facilities at TUNL and use the 2 H(d vector, n vector) 3 He reaction as a source of low-energy polarized neutrons. Our methods permit measurements to a high statistical accuracy over a large fraction of three-nucleon phase space. The techniques are described and experimental spectra along with kinematic calculations are presented. (orig.)

  20. Investigation of the tensor analyzing power Ayy in the reaction A(d polarized, p)X at large transverse momenta of proton

    International Nuclear Information System (INIS)

    Afanas'ev, S.V.; Arkhipov, V.V.; Azhgirej, L.S.

    1997-01-01

    An experiment on the studying of the tensor analyzing power A yy in the reaction A(d polarized, p)X at large transverse momenta of proton using a polarized deuteron beam of LHE accelerator complex has been proposed. These measurements could provide the valuable information on the spin structure of the deuteron at short distances. The estimation of the beam request for SPHERE set-up is performed

  1. Modelling voltage sag mitigation using dynamic voltage restorer and analyzing power quality issue

    Science.gov (United States)

    Ismail, Nor Laili; Hidzir, Hizrin Dayana Mohd; Thanakodi, Suresh; Nazar, Nazatul Shiema Moh; Ibrahim, Pungut; Ali, Che Ku Muhammad Sabri Che Ku

    2018-02-01

    Power quality problem which are arise due to a fault or a pulsed load can have caused an interruption of critical load. The modern power systems are becoming more sensitive to the quality of the power supplied by the utility company. Voltage sags and swells, flicker, interruptions, harmonic distortion and other distortion to the sinusoidal waveform are the examples of the power quality problems. The most affected due to these problems is industrial customers who use a lot of sensitive equipment. There has suffered a huge loss to these problems. Resulting of broken or damage equipment if voltage sag exceeds the sensitive threshold of the equipment. Thus, device such as Static Synchronous Compensator (STATCOM) and Dynamic Voltage Restorer (DVR) has been created to solve this problem among users. DVR is a custom power device that most effective and efficient. This paper intended to report the DVR operations during voltage sag compensation.

  2. Comprehensive Power Losses Model for Electronic Power Transformer

    DEFF Research Database (Denmark)

    Yue, Quanyou; Li, Canbing; Cao, Yijia

    2018-01-01

    and considering the impact of the non-unity power factor and the three-phase unbalanced current, the overall power losses in the distribution network when using the EPT to replace the conventional transformer is analyzed, and the conditions in which the application of the EPT can cause less power losses...... reduced power losses in the distribution network require a comprehensive consideration when comparing the power losses of theEPT and conventional transformer. In this paper, a comprehensive power losses analysis model for the EPT in distribution networks is proposed. By analyzing the EPT self-losses......The electronic power transformer (EPT) has highe rpower losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current and reduce the line power losses in the distribution network.Therefore, the higher losses of the EPT and the consequent...

  3. Comprehensive Power Losses Model for Electronic Power Transformer

    DEFF Research Database (Denmark)

    Yue, Quanyou; Li, Canbing; Cao, Yijia

    2018-01-01

    The electronic power transformer (EPT) has highe rpower losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current and reduce the line power losses in the distribution network.Therefore, the higher losses of the EPT and the consequent...... reduced power losses in the distribution network require a comprehensive consideration when comparing the power losses of theEPT and conventional transformer. In this paper, a comprehensive power losses analysis model for the EPT in distribution networks is proposed. By analyzing the EPT self......-losses and considering the impact of the non-unity power factor and the three-phase unbalanced current, the overall power losses in the distribution network when using the EPT to replace the conventional transformer is analyzed, and the conditions in which the application of the EPT can cause less power losses...

  4. Contamination Analyzer

    Science.gov (United States)

    1994-01-01

    Measurement of the total organic carbon content in water is important in assessing contamination levels in high purity water for power generation, pharmaceutical production and electronics manufacture. Even trace levels of organic compounds can cause defects in manufactured products. The Sievers Model 800 Total Organic Carbon (TOC) Analyzer, based on technology developed for the Space Station, uses a strong chemical oxidizing agent and ultraviolet light to convert organic compounds in water to carbon dioxide. After ionizing the carbon dioxide, the amount of ions is determined by measuring the conductivity of the deionized water. The new technique is highly sensitive, does not require compressed gas, and maintenance is minimal.

  5. VECTOR AND TENSOR ANALYZING POWERS IN THE PB-208(D)OVER-RIGHT-ARROW,T)PB-207 REACTION AT 200 AND 360 MEV

    NARCIS (Netherlands)

    VANDEWIELE, J; LANGEVINJOLIOT, H; GUILLOT, J; ROSIER, LH; WILLIS, A; MORLET, M; DUHAMELCHRETIEN, G; GERLIC, E; TOMASIGUSTAFSSON, E; BLASI, N; MICHELETTI, S; VANDERWERF, SY

    Cross sections and vector and tensor analyzing powers for the main levels in Pb-207 have been measured via the Pb-208(d over arrow pointing right, t)Pb-207 reaction at 200 and 360 MeV incident energies. A(y) and A(yy) spin observables allow a clear identification of the valence levels, especially at

  6. COMMIX-PPC: A three-dimensional transient multicomponent computer program for analyzing performance of power plant condensers

    International Nuclear Information System (INIS)

    Chien, T.H.; Domanus, H.M.; Sha, W.T.

    1993-02-01

    The COMMIX-PPC computer pregrain is an extended and improved version of earlier COMMIX codes and is specifically designed for evaluating the thermal performance of power plant condensers. The COMMIX codes are general-purpose computer programs for the analysis of fluid flow and heat transfer in complex Industrial systems. In COMMIX-PPC, two major features have been added to previously published COMMIX codes. One feature is the incorporation of one-dimensional equations of conservation of mass, momentum, and energy on the tube stile and the proper accounting for the thermal interaction between shell and tube side through the porous-medium approach. The other added feature is the extension of the three-dimensional conservation equations for shell-side flow to treat the flow of a multicomponent medium. COMMIX-PPC is designed to perform steady-state and transient. Three-dimensional analysis of fluid flow with heat transfer tn a power plant condenser. However, the code is designed in a generalized fashion so that, with some modification, it can be used to analyze processes in any heat exchanger or other single-phase engineering applications. Volume I (Equations and Numerics) of this report describes in detail the basic equations, formulation, solution procedures, and models for a phenomena. Volume II (User's Guide and Manual) contains the input instruction, flow charts, sample problems, and descriptions of available options and boundary conditions

  7. Using Model Checking for Analyzing Distributed Power Control Problems

    DEFF Research Database (Denmark)

    Brihaye, Thomas; Jungers, Marc; Lasaulce, Samson

    2010-01-01

    Model checking (MC) is a formal verification technique which has been known and still knows a resounding success in the computer science community. Realizing that the distributed power control ( PC) problem can be modeled by a timed game between a given transmitter and its environment, the authors...... objectives a transmitter-receiver pair would like to reach. The network is modeled by a game where transmitters are considered as timed automata interacting with each other. The objectives are then translated into timed alternating-time temporal logic formulae and MC is exploited to know whether the desired...

  8. The analyzing power Asub(y)(theta) for the elastic scattering of 12 MeV neutrons from deuterons

    International Nuclear Information System (INIS)

    Tornow, W.; Lisowski, P.W.; Byrd, R.C.; Walter, R.L.

    1978-01-01

    The analyzing power Asub(y)(theta) was obtained at 10 0 intervals between 30 0 (lab) to 120 0 (lab) for 2 H(n, n) 2 H at 12.0 MeV. The polarized neutron beam employed in the measurement was obtained by using neutrons emitted at 0 0 from the polarization transfer reaction 2 H(d(pol), n(pol)) 3 He. The accuracy in the Asub(y)(theta) values that was achieved ranged from +- 0.006 to +- 0.013. Comparison of the data to Asub(y)(theta) results obtained at 12 MeV for the charge symmetric reaction 2 H(p, p) 2 H shows that the two Asub(y)(theta) distributions are equal to within the above accuracy. (Auth.)

  9. Comparison of analyzing power and polarization in the reaction 3H(p,n)3He. Pt. 2

    International Nuclear Information System (INIS)

    Tornow, W.; Byrd, R.C.; Lisowski, P.W.; Walter, R.L.; Donoghue, T.R.

    1981-01-01

    The polarization Psup(y) for the 3 H(p,n) 3 He reaction was measured for energies between 2 and 4 MeV. Special care was given to minimizing the effects of background and to interpreting the experimental spectra. The new values for Psup(y) are significantly higher than previous values, and comparison to the available data for the analyzing power Asub(y) for the same reaction now shows that in this energy range Psup(y) ad Asub(y) are equal within experimental uncertainties. This equality negates earlier conclusions that sizeable differences existed between these observables. In particular, our new results demonstrate that in this reaction the effects of charge symmetry breaking on differences between these observables must be small. (orig.)

  10. Analyzing powers for (p,t) transitions to the first-excited 2+ states of medium-mass nuclei and nuclear collective motions

    International Nuclear Information System (INIS)

    Nagano, K.; Aoki, Y.; Kishimoto, T.; Yagi, K.

    1983-01-01

    Vector analyzing powers A(theta) and differential cross sections σ(theta) have been measured, with the use of a polarized proton beam of 22.0 MeV and a magnetic spectrograph, for (p,t) reactions leading to the first-excited 2 + (2 1 + ) states of the following eighteen nuclei of N = 50 - 82: sup(92,94,96)Mo, sup(98,100,102)Ru, sup(102,104,106,108)Pd, sup(110,112,114)Cd, 116 Sn, sup(120,126,128)Te, and 136 Ba. In addition A(theta) and σ(theta) for sup(104,110)Pd(p,t) sup(102,108) Pd(0sub(g) + ,2 1 + ) transitions have been measured at Esub(p) = 52.2 MeV. The experimental results are analyzed in terms of the first- and second-order DWBA including both inelastic two-step processes and sequential transfer (p,d)(d,t) two-step processes. Inter-ference effect between the direct and the two-step processes is found to play an essential role in the (p,t) reactions. A sum-rule method for calculating the (p,d)(d,t) spectroscopic amplitudes has been developed so as to take into account the ground-state correlation in odd-A nuclei. The nuclear-structure wave functions are constructed under the boson expansion method and the quasiparticle random phase approximation (qp RPA) method by using the monopole-pairing, quadrupole-pairing, and QQ forces. The characteristic features of the experimental A(theta) and σ(theta) are better explained in terms of the boson expansion method than in terms of the qp RPA. Dependence of the (p,t) analyzing powers on the static electric quadrupole moment of the 2 1 + state is found to be strong because of the reorientation (anharmonic) effect in the 2 1 + yiedls 2 1 + transfer process. (J.P.N.)

  11. Measurement of effective analyzing powers for the NTOF polarimeter at LAMPF and DLL(0 degree) for Gamow-Teller transitions in p-shell nuclei

    International Nuclear Information System (INIS)

    Mercer, D.J.

    1993-01-01

    Measurements of neutron polarization from (rvec p,rvec n) reactions can provide valuable clues toward understanding the isovector nucleon-nucleus interaction. A neutron time-of-flight polarimeter has been constructed at the Los Alamos Meson Physics Facility to perform such measurements, but before the polarimeter can be used, its effective analyzing powers must be determined. This is accomplished by using the 14 C(rvec p,rvec n) 14 N reaction at a bombarding energy of 494 MeV to produce a beam of neutrons with known polarization, illuminating the detector with these neutrons, and measuring the azimuthal asymmetries after scattering from a hydrogenous analyzer fluid within the detector. Secondary measurements are made using the 2 H(rvec p,rvec n) 2 p reaction with bombarding energies of 318 and 494 MeV to produce a polarized neutron beam. The results from (rvec np) analyzing reactions within the detector agree with values anticipated from free nucleon-nucleon analyzing powers, but the results from (rvec np) analyzing reactions display a more than 33% reduction from the anticipated values. Additionally, measurements are made of the polarization transfer coefficient D LL (0 degree) for rvec p,rvec n Gamow-Teller reactions on 2 H, 7 Li 12 C, and 14 C targets. For a purely central interaction, one would expect that D LL (0 degree) ∼ -1/3 in the plane wave limit, but a simple average of the Jπ = 0 + → 1 + results at a bombardment energy of 494 MeV gives D LL (0 degree) = -0.689 ± 0.044. Thus, the measurements indicate that the nucleon-nucleus interaction -- which is largely central at 200 MeV -- has strong tensor contributions at higher energy

  12. Mini Total Organic Carbon Analyzer (miniTOCA)

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this development is to create a prototype hand-held, 1 to 2 liter size battery-powered Total Organic Carbon Analyzer (TOCA). The majority of...

  13. Techniques for vector analyzing power measurements of the sup 2 H(n vector,np)n breakup reaction at low energies

    Energy Technology Data Exchange (ETDEWEB)

    Howell, C.R.; Tornow, W.; Pfuetzner, H.G.; Li Anli; Roberts, M.L.; Murphy, K.; Felsher, P.D.; Weisel, G.J.; Naqvi, A.; Walter, R.L. (Duke Univ., Durham, NC (USA) Triangle Universities Nuclear Lab., Durham, NC (USA)); Lambert, J.M.; Treado, P.A. (Georgetown Univ., Washington, DC (USA). Dept. of Physics); Slaus, I. (Institut Rudjer Boskovic, Zagreb (Yugoslavia))

    1990-05-10

    Experimental methods to measure the vector analyzing powers over a broad range of kinematic configurations in the n-d breakup reaction have been developed at TUNL. These techniques employ the polarized beam facilities at TUNL and use the {sup 2}H(d vector, n vector){sup 3}He reaction as a source of low-energy polarized neutrons. Our methods permit measurements to a high statistical accuracy over a large fraction of three-nucleon phase space. The techniques are described and experimental spectra along with kinematic calculations are presented. (orig.).

  14. KWU Nuclear Plant Analyzer

    International Nuclear Information System (INIS)

    Bennewitz, F.; Hummel, R.; Oelmann, K.

    1986-01-01

    The KWU Nuclear Plant Analyzer is a real time engineering simulator based on the KWU computer programs used in plant transient analysis and licensing. The primary goal is to promote the understanding of the technical and physical processes of a nuclear power plant at an on-site training facility. Thus the KWU Nuclear Plant Analyzer is available with comparable low costs right at the time when technical questions or training needs arise. This has been achieved by (1) application of the transient code NLOOP; (2) unrestricted operator interaction including all simulator functions; (3) using the mainframe computer Control Data Cyber 176 in the KWU computing center; (4) four color graphic displays controlled by a dedicated graphic computer, no control room equipment; and (5) coupling of computers by telecommunication via telephone

  15. Low-Power Architecture for an Optical Life Gas Analyzer

    Science.gov (United States)

    Pilgrim, Jeffrey; Vakhtin, Andrei

    2012-01-01

    Analog and digital electronic control architecture has been combined with an operating methodology for an optical trace gas sensor platform that allows very low power consumption while providing four independent gas measurements in essentially real time, as well as a user interface and digital data storage and output. The implemented design eliminates the cross-talk between the measurement channels while maximizing the sensitivity, selectivity, and dynamic range for each measured gas. The combination provides for battery operation on a simple camcorder battery for as long as eight hours. The custom, compact, rugged, self-contained design specifically targets applications of optical major constituent and trace gas detection for multiple gases using multiple lasers and photodetectors in an integrated package.

  16. Problems in public perception of nuclear power: Fears and risks analyzed

    International Nuclear Information System (INIS)

    Ray, D.L.

    1984-01-01

    In an ideal world, the industrial nations would be going all out for a massive nuclear energy program, not only to provide electricity for industrial, commercial, and domestic use and propulsion for merchant vessels, but also to make process heat to replace, to the greatest extent possible, the burning of fossil fuels. This would free up significant quantities of oil for the developing countries to tide them over until they will have the technical base and industrial infrastructure for their own nuclear or advanced high technology energy systems. But it is not an ideal world. An it is ironic that opposition to nuclear energy has emerged and grown and presently is spreading in most of the Western industrialized, energy-consuming nations. The anti-nuclear factions are often the same people who profess to care for the well being of the third world nations, but their actions are a contradiction in terms. Perhaps they have not stopped to consider the dreadful consequences of abandoning the nuclear power option or thought of a future world consisting of states perpetually at war with each other over control of whatever remained of each other's expendable energy resources. If nuclear power fails to fulfill its bright promise to provide sufficient energy for improved living conditions for all the world's people, it will not be because of flaws in the technology or failure to resolve the questions of fuel supply or waste disposal. It will be because the public perceives nuclear power to be undesirable. The author discusses his views on this subject in future detail

  17. Analyzing power and differential cross section at 9. 9, 11. 9 and 13. 9 MeV for Ca(n,n)Ca

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W.; Woye, E.; Mack, G. (Tuebingen Univ. (Germany, F.R.). Physikalisches Inst.); Floyd, C.E.; Murphy, K.; Guss, P.P.; Wender, S.A.; Byrd, R.C.; Walter, R.L. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA))

    1982-09-13

    The analyzing power and differential cross section for elastic neutron scattering from calcium have been measured at 9.9, 11.9 and 13.9 MeV using the /sup 2/H(d,n)/sup 3/He source reaction and neutron time-of-flight (t.o.f.) techniques to detect the scattered neutrons. Polarized neutron beams were produced via the polarization transfer reaction /sup 2/H(d vector,n vector)/sup 3/He at THETA = 0/sup 0/. The data have been corrected for finite geometry and multiple scattering effects. None of the global neutron-nucleus optical model parameter sets usually referred to in the literature reproduces the present cross-section and analyzing power data. Individual as well as energy-averaged fits of the data resulting from new optical model searches are presented. It is shown that the quoted uncertainties of a recent empirical determination of the real part ..delta..Vsub(C) of the Coulomb correction term are probably underestimated. Our imaginary Coulomb correction term ..delta..Wsub(C) agrees quite well with both a very recent empirical determination and theoretical studies. Although the quality of the fits to the data can be improved by adding iota-dependent potentials to the general optical potential, no definite conclusions can be drawn from the present data as to whether or not iota-dependent potentials are important in neutron-calcium scattering in the energy range investigated. The data have also been analyzed using a Fourier-Bessel series description of the real central optical potential. Comparing the chi/sup 2/ values, the experimental data are better reproduced by the Fourier-Bessel method than by our Woods-Saxon optical model analyses. The Fourier-Bessel potentials obtained show strong deviations from the standard Woods-Saxon shape but are in good agreement with calculations using the nuclear structure approach.

  18. Analyzing power and differential cross section at 9.9, 11.9 and 13.9 MeV for Ca(n,n)Ca

    International Nuclear Information System (INIS)

    Tornow, W.; Woye, E.; Mack, G.; Clegg, T.

    1982-01-01

    The analyzing power and differential cross section for elastic neutron scattering from calcium have been measured at 9.9, 11.9 and 13.9 MeV using the 2 H(d,n) 3 He source reaction and neutron time-of-flight (t.o.f.) techniques to detect the scattered neutrons. Polarized neutron beams were produced via the polarization transfer reaction 2 H(d vector,n vector) 3 He at THETA = 0 0 . The data have been corrected for finite geometry and multiple scattering effects. None of the global neutron-nucleus optical model parameter sets usually referred to in the literature reproduces the present cross-section and analyzing power data. Individual as well as energy-averaged fits of the data resulting from new optical model searches are presented. It is shown that the quoted uncertainties of a recent empirical determination of the real part ΔVsub(C) of the Coulomb correction term are probably underestimated. Our imaginary Coulomb correction term ΔWsub(C) agrees quite well with both a very recent empirical determination and theoretical studies. Although the quality of the fits to the data can be improved by adding iota-dependent potentials to the general optical potential, no definite conclusions can be drawn from the present data as to whether or not iota-dependent potentials are important in neutron-calcium scattering in the energy range investigated. The data have also been analyzed using a Fourier-Bessel series description of the real central optical potential. Comparing the chi 2 values, the experimental data are better reproduced by the Fourier-Bessel method than by our Woods-Saxon optical model analyses. The Fourier-Bessel potentials obtained show strong deviations from the standard Woods-Saxon shape but are in good agreement with calculations using the nuclear structure approach. (orig.)

  19. Improvement of the nuclear plant analyzer for Korean Standard Nuclear Power Plants

    International Nuclear Information System (INIS)

    Choi, Sung Soo; Han, Byoung Sub; Suh, Jae Seung; Son, Dae Seong

    2005-04-01

    Accurate analysis of the operating characteristics of Nuclear Power Plants provides valuable information for both norman and abnormal operation. The information can be used for the enhancement of plant performance and safety. Usually, such analysis is performed using computer codes used for plant design or simulators. However, their usages are limited because special expertise is required to use the computer codes and simulators are not portable. Therefore, it deemed necessary to develop an NPA which minimizes those limitations and can be used for the analysis and simulation of Nuclear Power Plants. The purpose of this study is to develop a real-time best-estimate NPA for the Korean Nuclear Power Plants(KSNP). The NPA is an interactive, high fidelity engineering simulator. NPA combines the process model simulating the plant behavior with the latest computer technology such as Graphical User Interface(GUI) and simulation executive for enhanced user interface. The process model includes models for a three-dimensional reactor core, the NSSS, secondary system including turbine and feedtrain, safety auxiliary systems, and various control systems. Through the verification and validation of the NPA, it was demonstrated that the NPA can realistically simulate the plant behaviors during transient and accident conditions

  20. Analyzing the Impacts of Increased Wind Power on Generation Revenue Sufficiency: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qin; Wu, Hongyu; Tan, Jin; Hodge, Bri-Mathias; Li, Wanning; Luo, Cheng

    2016-08-01

    The Revenue Sufficiency Guarantee (RSG), as part of make-whole (or uplift) payments in electricity markets, is designed to recover the generation resources' offer-based production costs that are not otherwise covered by their market revenues. Increased penetrations of wind power will bring significant impacts to the RSG payments in the markets. However, literature related to this topic is sparse. This paper first reviews the industrial practices of implementing RSG in major U.S. independent system operators (ISOs) and regional transmission operators (RTOs) and then develops a general RSG calculation method. Finally, an 18-bus test system is adopted to demonstrate the impacts of increased wind power on RSG payments.

  1. Analyzing powers and proton spin transfer coefficients in the elastic scattering of 800 MeV polarized protons from an L-type polarized deuteron target at small momentum transfers

    International Nuclear Information System (INIS)

    Adams, D.L.

    1986-10-01

    Analyzing powers and spin transfer coefficients which describe the elastic scattering of polarized protons from a polarized deuteron target have been measured. The energy of the proton beam was 800 MeV and data were taken at laboratory scattering angles of 7, 11, 14, and 16.5 degrees. One analyzing power was also measured at 180 degrees. Three linearly independent orientations of the beam polarization were used and the target was polarized parallel and antiparallel to the direction of the beam momentum. The data were taken with the high resolution spectrometer at the Los Alamos Meson Physics Facility (experiment 685). The results are compared with multiple scattering predictions based on Dirac representations of the nucleon-nucleon scattering matrices. 27 refs., 28 figs., 4 tabs

  2. BWR plant analyzer development at BNL

    International Nuclear Information System (INIS)

    Cheng, H.S.; Wulff, W.; Mallen, A.N.; Lekach, S.V.; Stritar, A.; Cerbone, R.J.

    1985-01-01

    Advanced technology for high-speed interactive nuclear power plant simulations is of great value for timely resolution of safety issues, for plant monitoring, and for computer-aided emergency responses to an accident. Presented is the methodology employed at BNL to develop a BWR plant analyzer capable of simulating severe plant transients at much faster than real-time process speeds. Five modeling principles are established and a criterion is given for selecting numerical procedures and efficient computers to achieve the very high simulation speeds. Typical results are shown to demonstrate the modeling fidelity of the BWR plant analyzer

  3. Emergency response training with the BNL plant analyzer

    International Nuclear Information System (INIS)

    Cheng, H.S.; Guppy, J.G.; Mallen, A.N.; Wulff, W.

    1987-01-01

    Presented is the experience in the use of the BNL Plant Analyzer for NRC emergency response training to simulated accidents in a BWR. The unique features of the BNL Plant Analyzer that are important for the emergency response training are summarized. A closed-loop simulation of all the key systems of a power plant in question was found essential to the realism of the emergency drills conducted at NRC. The faster than real-time simulation speeds afforded by the BNL Plant Analyzer have demonstrated its usefulness for the timely conduct of the emergency response training

  4. DCS cabinet power loss analysis for CPR1000 nuclear power plant

    International Nuclear Information System (INIS)

    Zhou Liang; Zhao Yanfeng; Sun Yongbin

    2014-01-01

    The DCS overall structure of CRP1000 nuclear power plant was introduced. Based on the RPC, the signal interface character and signal processing mechanism on the key root were analyzed. By the power loss analyzing of RPC, the RPC loss power may lead reactor trip signal from anticipated transient without scram (ATWS) system. The results indicate that it is necessary to search DCS cabinet power loss analysis. Optimizing and assigning the main water flow signals can avoid trigger reactor trip signal by mistake. The DCS cabinet power loss analysis can optimize the I and C (instrumentation and control) design and increase the nuclear plant's reliability. (authors)

  5. The low-energy neutron-deuteron analyzing power and the sup 3 P sub 0,1,2 interactions of nucleon-nucleon potentials

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W.; Howell, C.R.; Alohali, M.; Chen, Z.P.; Felsher, P.D.; Hanly, J.M.; Walter, R.L.; Weisel, G. (Duke Univ., Durham, NC (USA). Dept. of Physics Triangle Universities Nuclear Lab., Durham, NC (USA)); Mertens, G. (Tuebingen Univ. (Germany, F.R.). Physikalisches Inst.); Slaus, I. (Institut Rudjer Boskovic, Zagreb (Yugoslavia)); Witala, H.; Gloeckle, W. (Bochum Univ. (Germany, F.R.). Inst. fuer Theoretische Physik 2)

    1991-03-28

    Data for the analyzing power A{sub y}({theta}) for the elastic scattering of neutrons from deuterons have been measured at 5.0, 6.5 and 8.5 MeV to an accuracy of +-0.0035. Surprisingly large differences have been observed at these low energies between the data and rigorous Faddeev calculations using the Paris and Bonn B nucleon-nucleon potentials. The A{sub y}({theta}) data provide a stringent test for our present understanding of the on-shell and off-shell {sup 3}P{sub 0,1,2} nucleon-nucleon interactions. (orig.).

  6. Differences in the analyzing powers of p-d and n-d elastic scattering data as possible evidence of charge symmetry breaking

    International Nuclear Information System (INIS)

    Vlahovic, B.; Soldi, A.

    1993-01-01

    The differences between the n-d and the p-d analyzing powers lend themselves to investigate Coulomb and charge symmetry breaking effects in the nucleon-nucleon interaction. We examine these differences over a range of angles, bracketing the Λ y maximum around 120 degrees, for energies from 3 to 14 MeV. We conclude that a correction of the data to account for the slowing down of tile proton under the Coulomb affect does not account for these differences and this suggests that charge symmetry breaking effect are possibly responsible

  7. Analyzing power measurement of pp elastic scattering in the Coulomb-nuclear interference region with the 200-GeV/c polarized-proton beam at Fermilab

    International Nuclear Information System (INIS)

    Akchurin, N.; Langland, J.; Onel, Y.; Bonner, B.E.; Corcoran, M.D.; Cranshaw, J.; Nessi-Tedaldi, F.; Nessi, M.; Nguyen, C.; Roberts, J.B.; Skeens, J.; White, J.L.; Bravar, A.; Giacomich, R.; Penzo, A.; Schiavon, P.; Zanetti, A.; Bystricky, J.; Lehar, F.; de Lesquen, A.; van Rossum, L.; Cossairt, J.D.; Read, A.L.; Derevschikov, A.A.; Matulenko, Y.A.; Meschanin, A.P.; Nurushev, S.B.; Patalakha, D.I.; Rykov, V.L.; Solovyanov, V.L.; Vasiliev, A.N.; Grosnick, D.P.; Hill, D.A.; Laghai, M.; Lopiano, D.; Ohashi, Y.; Shima, T.; Spinka, H.; Stanek, R.W.; Underwood, D.G.; Yokosawa, A.; Funahashi, H.; Goto, Y.; Imai, K.; Itow, Y.; Makino, S.; Masaike, A.; Miyake, K.; Nagamine, T.; Saito, N.; Yamashita, S.; Iwatani, K.; Kuroda, K.; Michalowicz, A.; Luehring, F.C.; Miller, D.H.; Maki, T.; Pauletta, G.; Rappazzo, G.F.; Salvato, G.; Takashima, R.

    1993-01-01

    The analyzing power A N of proton-proton elastic scattering in the Coulomb-nuclear interference region has been measured using the 200-GeV/c Fermilab polarized proton beam. A theoretically predicted interference between the hadronic non-spin-flip amplitude and the electromagnetic spin-flip amplitude is shown for the first time to be present at high energies in the region of 1.5x10 -3 to 5.0x10 -2 (GeV/c) 2 four-momentum transfer squared, and our results are analyzed in connection with theoretical calculations. In addition, the role of possible contributions of the hadronic spin-flip amplitude is discussed

  8. Giessen polarization facility. III. Multi-detector analyzing system

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H H; Stock, R; Arnold, W; Berg, H; Huttel, E; Ulbricht, J; Clausnitzer, G [Giessen Univ. (Germany, F.R.). Strahlenzentrum

    1977-06-15

    An analyzing system with a PDP 11 computer and a digital multiplexer is described. It allows to accept signals from 16 detectors with individual ADCs simultaneously. For measurements of analyzing powers the polarization of the ion beam can be switched to zero with a frequency of 1 kHz. The switching operation additionally controls the handling of the detector pulses. The software contains special programs for the analysis of polarization experiments.

  9. Risk of loss power for ATWT in Daya Bay and Ling'ao nuclear power stations

    International Nuclear Information System (INIS)

    Guo Cheng

    2010-01-01

    In order to analyze the differences between the Anticipated Transient Without Reactor Trip (ATWT) and other reactor protection methods, this paper analyzes in detail the realizing means of ATWT and the effect of lost of power supply on the units based on Daya Bay and Ling'ao Nuclear Power Stations by system wiring diagram. Based on the comprehensive analysis,this paper proposes the sequence for powering when recovering the power source after ATWT power supply (LCC/LNE) loss for Daya Bay and Ling'ao Nuclear Power Stations. (authors)

  10. Comprehensive method for analyzing the power conversion efficiency of organic solar cells under different spectral irradiances considering both photonic and electrical characteristics

    International Nuclear Information System (INIS)

    Chong, Kok-Keong; Khlyabich, Petr P.; Hong, Kai-Jeat; Reyes-Martinez, Marcos; Rand, Barry P.; Loo, Yueh-Lin

    2016-01-01

    Highlights: • Method to analyze power-conversion efficiency under various solar irradiance. • Power-conversion efficiency at local irradiance is 5.4% higher than AM1.5G. • Diffuse local irradiance has gain of 23.7–27.9% relative to AM1.5G conditions. • Annual average energy density yield is estimated as 31.89 kW h/m 2 in Malaysia. - Abstract: The solar spectral irradiance varies significantly for different locations and time due to latitude, humidity, cosine effect of incident sunlight, etc. For convenience, the power-conversion efficiency of a solar cell is referenced to the international standard of AM1.5G spectral irradiance, which inevitably leads to varying performance of deployed solar cells under the specific local climate and insolation conditions. To predict the actual performance of solar cells under local climate conditions, we propose a methodology to compute the power-conversion efficiency of organic photovoltaic cells based upon indoor measurement with a solar simulator, the measured local solar spectrum, and making use of both optical and electrical factors. From our study, the annual average energy density yield of poly(3-hexylthiophene):phenyl-C 61 -butyric acid methyl ester (P3HT:PCBM) bulk-heterojunction organic solar cells under the local spectral irradiance of Malaysia is estimated to be 31.89 kW h/m 2 and the power-conversion efficiency is increased by 5.4% compared to that measured under AM1.5G conditions. In addition, diffuse solar irradiance (cloudy condition) was found to be in favor of P3HT:PCBM solar cells, with gain of 23.7–27.9% relative to AM1.5G conditions.

  11. Probabilistic Physics-Based Risk Tools Used to Analyze the International Space Station Electrical Power System Output

    Science.gov (United States)

    Patel, Bhogila M.; Hoge, Peter A.; Nagpal, Vinod K.; Hojnicki, Jeffrey S.; Rusick, Jeffrey J.

    2004-01-01

    This paper describes the methods employed to apply probabilistic modeling techniques to the International Space Station (ISS) power system. These techniques were used to quantify the probabilistic variation in the power output, also called the response variable, due to variations (uncertainties) associated with knowledge of the influencing factors called the random variables. These uncertainties can be due to unknown environmental conditions, variation in the performance of electrical power system components or sensor tolerances. Uncertainties in these variables, cause corresponding variations in the power output, but the magnitude of that effect varies with the ISS operating conditions, e.g. whether or not the solar panels are actively tracking the sun. Therefore, it is important to quantify the influence of these uncertainties on the power output for optimizing the power available for experiments.

  12. General considerations concerning the use of the X-ray analyzer RALE in industry

    International Nuclear Information System (INIS)

    Mueller, D.; Morgenstern, P.; Riedel, W.

    1983-01-01

    The X-ray analyzer RALE for light elements was tested under laboratory conditions. Particularities of X-ray analysis concerning the use of the proportional scintillation detector for X-radiation and an alpha particle source for excitation are described. The performance of the analyzer was estimated. The results demonstrate that this analyzer will be of great advantage for solution of many analytical problems in industry. This is illustrated by means of any applications concerning the determination of concentration power engineering of elements and the thickness of thin layers in the field of power engineering including nuclear power engineering as well as in the field of metallurgy. The essential advantage of this analytical method consists in the extention of X-ray analysis to the region of elements with low atomic numbers. (author)

  13. Analyzing power in inclusive π+ and π- production at high xF with a 200 GeV polarized proton beam

    International Nuclear Information System (INIS)

    Adams, D.L.; Bonner, B.E.; Buchanan, J.A.; Clement, J.M.; Corcoran, M.D.; Cranshaw, J.; Nessi-Tedaldi, F.; Nessi, M.; Nguyen, C.; Phillips, G.C.; Roberts, J.B.; Skeens, J.; White, J.L.; Akchurin, N.; Langland, J.; Onel, Y.; Belikov, N.I.; Derevschikov, A.A.; Grachov, O.A.; Matulenko, Yu.A.; Meschanin, A.P.; Nurushev, S.B.; Patalakha, D.I.; Rykov, V.L.; Solovyanov, V.L.; Vasiliev, A.N.; Bystricky, J.; Lehar, F.; Lesquen, A. de; Cossairt, J.D.; Read, A.L.; En'yo, H.; Funahashi, H.; Goto, Y.; Imai, K.; Itow, Y.; Makino, S.; Masaike, A.; Miyake, K.; Nagamine, T.; Saito, N.; Yamashita, S.; Grosnick, D.P.; Hill, D.A.; Lopiano, D.; Ohashi, Y.; Spinka, H.; Stanek, R.W.; Underwood, D.G.; Yokosawa, A.; Iwatani, K.; Krueger, K.W.; Kuroda, K.; Michalowicz, A.; Luehring, F.C.; Miller, D.H.; Maki, T.; Pauletta, G.; Penzo, A.; Schiavon, P.; Zanetti, A.; Van Rossum, L.; Salvato, G.; Villari, A.; Takashima, R.; Takeutchi, F.; Tamura, N.; Tanaka, N.; Yoshida, T.

    1991-01-01

    The analyzing power in inclusive charged pion production has been measured using the 200 GeV Fermilab polarized proton beam. A striking dependence in χ F is observed in which A N increases from 0 to 0.42 with increasing χ F for the π + data and decreases from 0 to -0.38 with increasing χ F for π - data. The kinematic range covered is 0.2≤χ F ≤0.9 and 0.2≤p T ≤2.0 GeV/c. In a simple model our data indicate that at large χ F the transverse spin of the proton is correlated with that of its quark constituents. (orig.)

  14. Decarbonizing Europe's power sector by 2050 — Analyzing the economic implications of alternative decarbonization pathways

    International Nuclear Information System (INIS)

    Jägemann, Cosima; Fürsch, Michaela; Hagspiel, Simeon; Nagl, Stephan

    2013-01-01

    The European Union aims to reduce greenhouse gas emissions by 80–95% in 2050 compared to 1990 levels. The transition towards a low-carbon economy implies the almost complete decarbonization of Europe's power sector, which could be achieved along various pathways. In this paper, we evaluate the economic implications of alternative energy policies for Europe's power sector by applying a linear dynamic electricity system optimization model in over 36 scenarios. We find that the costs of decarbonizing Europe's power sector by 2050 vary between 139 and 633 bn € 2010 , which corresponds to an increase of between 11% and 44% compared to the total system costs when no CO 2 reduction targets are implemented. In line with economic theory, the decarbonization of Europe's power sector is achieved at minimal costs under a stand-alone CO 2 reduction target, which ensures competition between all low-carbon technologies. If, however, renewable energies are exempted from competition via supplementary renewable energy (RES-E) targets or if investments in new nuclear and CCS power plants are politically restricted, the costs of decarbonization significantly rise. Moreover, we find that the excess costs of supplementary RES-E targets depend on the acceptance of alternative low carbon technologies. For example, given a complete nuclear phase-out in Europe by 2050 and politically implemented restrictions on the application of CCS to conventional power plants, supplementary RES-E targets are redundant. While in such a scenario the overall costs of decarbonization are comparatively high, the excess costs of supplementary RES-E targets are close to zero. - Highlights: • We evaluate the economic implications of alternative energy policies for Europe's power sector. • Total decarbonization costs vary between 139 and 633 billion € 2010 up to 2050. • Decarbonization at minimal costs is ensured by competition between all low carbon technologies. • Excess costs of supplementary

  15. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Directory of Open Access Journals (Sweden)

    S. E. Brown

    2018-03-01

    Full Text Available Nitrous oxide (N2O fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2. The system features a relatively small, single-pass sample cell (200 mL that provides good frequency response with a lower-powered pump ( ∼  250 W. A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016 in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: −26.1 to 31.6 °C. The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz and similar to that of a closed

  16. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Science.gov (United States)

    Brown, Shannon E.; Sargent, Steve; Wagner-Riddle, Claudia

    2018-03-01

    Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2). The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump ( ˜ 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 °C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4

  17. Life cycle assessment of a HYSOL concentrated solar power plant: Analyzing the effect of geographic location

    NARCIS (Netherlands)

    Corona, B.; Ruiz, Diego; San Miguel, Guillermo

    2016-01-01

    Concentrating Solar Power (CSP) technology is developing in order to achieve higher energy efficiency, reduced economic costs, and improved firmness and dispatchability in the generation of power on demand. To this purpose, a research project titled HYSOL has developed a new power plant, consisting

  18. Analyzing composability of applications on MPSoC platforms

    NARCIS (Netherlands)

    Kumar, A.; Mesman, B.; Theelen, B.D.; Corporaal, H.; Yajun, H.

    2008-01-01

    Modern day applications require use of multi-processor systems for reasons of erformance, scalability and power efficiency. As more and more applications are integrated in a single system, mapping and analyzing them on a multi-processor platform becomes a multidimensional problem. Each possible set

  19. Analyzing power measurements for n-p scattering between 13.5 and 16.9 MeV

    International Nuclear Information System (INIS)

    Tornow, W.; Lisowski, P.W.; Byrd, R.C.; Walter, R.L.

    1980-01-01

    The analyzing power A%sub(Y)(theta) for neutron-proton scattering has been measured for theta = 90 0 (c.m.) from 13.5 to 16.9 MeV and from theta = 50 0 to 145 0 (c.m.) at 16.9 MeV. Extensive Monte Carlo calculations have been made to correct for multiple scattering effects. Overall uncertainties are about +- 0.002. All the A%sub(Y)(theta) data, but primarily those at 16.9 MeV, disagree with predictions based on the phase-shift sets which have been derived previously by way of global analyses of nucleon-nucleon scattering data. Data for the product delta(theta)A%sub(Y)(theta) have been fitted with an expansion of the form (sin theta)(a 0 + a 1 cos theta + a 2 cos 2 theta). For the first time the need for a non-zero a 2 has been illustrated for energies below 20 MeV. This parameter is shown to be related to the nucleon-nucleon F-state spin-orbit phase parameter. In addition, the P, D, and F spin-orbit phase parameter values derived from the present data differ significantly from the ones based on the Yale-IV and Livermore-X global analyses. The derived D and F spin-orbit phase parameters also differ from those obtained in the recent analysis of nucleon-nucleon scattering data by Arndt et al. (orig.)

  20. Analyze and Improve Lifetime in 3L-NPC Inverter from Power Cycle and Thermal Balance

    DEFF Research Database (Denmark)

    Chen, Quan; Chen, Zhe; Wang, Qunjing

    2014-01-01

    Three-level Neutral-point-clamped (3L-NPC) topology is becoming a realistic alternative to the conventional one in high-voltage and high-power application. Studies show that the power cycling mean time to failure (MTTF) of the semiconductor bond wire in 3L-NPC inverter system may be very short...... under some common conditions. Firstly, this paper shows the impact of some key parameters on power electronic system lifetime according the analysis of semiconductor failure mechanism. Secondly, a switching frequency reduction method based on the position relationship between the flowing current...... and load voltage is applied to reduce power cycle and switching losses. And then, three-level active neutral point-clamped topology is taken into account to wake the most thermo stressed device. In order to validate the improve lifetime method in this paper, a 2MW 3L-NPC converter used in wind energy has...

  1. Miniature multichannel analyzer for process monitoring

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.; Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.; Wiig, L.G.; Ianakiev, K.D.

    1993-01-01

    A new, 4,000-channel analyzer has been developed for gamma-ray spectroscopy applications. A design philosophy of hardware and software building blocks has been combined with design goals of simplicity, compactness, portability, and reliability. The result is a miniature, modular multichannel analyzer (MMMCA), which offers solution to a variety of nondestructive assay (NDA) needs in many areas of general application, independent of computer platform or operating system. Detector-signal analog electronics, the bias supply, and batteries are included in the virtually pocket-size, low-power MMMCA unit. The MMMCA features digital setup and control, automated data reduction, and automated quality assurance. Areas of current NDA applications include on-line continuous (process) monitoring, process material holdup measurements, and field inspections

  2. Analyzing the differences between Seoul versus other Regions in response to Nuclear Power Information

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Seung Kook [KAERI, Daejeon (Korea, Republic of); Kim, Chul Min [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    Seoul citizens do not feel any seriousness about the recent issues related to NPP, since they do not have NPP in nearby region. Despite Seoul Metropolitan Government has been conducting 'reduce one NPP' campaign for 4 years with large budget, the awareness of Seoul citizens' NPP is very low. From this point of view, it can be seen that the campaign failed to increase the awareness of NPP. Besides, Seoul citizens are living in the most distant region from NPP so that they lack the opportunity to access the information about the safety of the facility in direct way. They formed overall image about nuclear power through information from the media and indirect experience. The public usually pay attention to negative or incendiary news more than the positive ones. They are more likely to have a simply negative image from incendiary news, such as the movement against radioactive waste disposal siting in Guleopdo and Buan, Fukushima accident, radioactive rain, Japanese seafood imports, nuclear scandal, etc. Even media that has positive nuances can raise doubts about nuclear power. In addition, the public usually have lower opportunity to feel an affinity for nuclear power, and show the problems related to nuclear power in the third party's stance. According to the mere exposure theory, it can be the cause of having negative stance.

  3. Power System Operation with Large Scale Wind Power Integration

    DEFF Research Database (Denmark)

    Suwannarat, A.; Bak-Jensen, B.; Chen, Z.

    2007-01-01

    to the uncertain nature of wind power. In this paper, proposed models of generations and control system are presented which analyze the deviation of power exchange at the western Danish-German border, taking into account the fluctuating nature of wind power. The performance of the secondary control of the thermal......The Danish power system starts to face problems of integrating thousands megawatts of wind power, which produce in a stochastic behavior due to natural wind fluctuations. With wind power capacities increasing, the Danish Transmission System Operator (TSO) is faced with new challenges related...... power plants and the spinning reserves control from the Combined Heat and Power (CHP) units to achieve active power balance with the increased wind power penetration is presented....

  4. Wind energy system time-domain (WEST) analyzers

    Science.gov (United States)

    Dreier, M. E.; Hoffman, J. A.

    1981-01-01

    A portable analyzer which simulates in real time the complex nonlinear dynamics of horizontal axis wind energy systems was constructed. Math models for an aeroelastic rotor featuring nonlinear aerodynamic and inertial terms were implemented with high speed digital controllers and analog calculation. This model was combined with other math models of elastic supports, control systems, a power train and gimballed rotor kinematics. A stroboscopic display system graphically depicting distributed blade loads, motion, and other aerodynamic functions on a cathode ray tube is included. Limited correlation efforts showed good comparison between the results of this analyzer and other sophisticated digital simulations. The digital simulation results were successfully correlated with test data.

  5. Cross sections and tensor analyzing powers Ayy of the reaction 1H(d-vector, pp)n in 'symmetric constant relative energy' geometries at Ed=19 MeV

    International Nuclear Information System (INIS)

    Ley, J.; Dueweke, C.; Emmerich, R.; Imig, A.; Paetz gen Schieck, H.; Golak, J.; Witala, H.; Epelbaum, E.; Deltuva, A.; Fonseca, A.C.; Gloeckle, W.; Meissner, U.-G.; Nogga, A.; Sauer, P.U.

    2006-01-01

    We measured the cross sections and tensor analyzing powers of the 1 H(d-vector,pp)n breakup reaction at E d =19 MeV in four symmetric constant relative energy (SCRE) configurations. The data are compared with theoretical predictions from four different approaches: the first based on high-precision (semi)phenomenological potentials alone or, the second, combined with model three-nucleon forces, and the third based on chiral forces up to next-to-next-to-leading order (NNLO) in the chiral expansion. In these cases the Coulomb interaction is not included. In addition, a fourth approach consists in a comparison with predictions based on CD Bonn including the Δ excitation and the Coulomb force. In all cases the measured cross sections are significantly below the theoretical values, whereas the magnitudes of the tensor analyzing powers agree within the error bars in three of the four cases. The apparent discrepancies in the breakup cross sections are similar to the known differences for the space-star breakup. This adds to the data base of unsolved low-energy discrepancies (puzzles)

  6. Development of a coal quality analyzer for application to power plants based on laser-induced breakdown spectroscopy

    Science.gov (United States)

    Zhang, Lei; Gong, Yao; Li, Yufang; Wang, Xin; Fan, Juanjuan; Dong, Lei; Ma, Weiguang; Yin, Wangbao; Jia, Suotang

    2015-11-01

    It is vitally important for a power plant to determine the coal property rapidly to optimize the combustion process. In this work, a fully software-controlled laser-induced breakdown spectroscopy (LIBS) based coal quality analyzer comprising a LIBS apparatus, a sampling equipment, and a control module, has been designed for possible application to power plants for offering rapid and precise coal quality analysis results. A closed-loop feedback pulsed laser energy stabilization technology is proposed to stabilize the Nd: YAG laser output energy to a preset interval by using the detected laser energy signal so as to enhance the measurement stability and applied in a month-long monitoring experiment. The results show that the laser energy stability has been greatly reduced from ± 5.2% to ± 1.3%. In order to indicate the complex relationship between the concentrations of the analyte of interest and the corresponding plasma spectra, the support vector regression (SVR) is employed as a non-linear regression method. It is shown that this SVR method combined with principal component analysis (PCA) enables a significant improvement in cross-validation accuracy by using the calibration set of coal samples. The root mean square error for prediction of ash content, volatile matter content, and calorific value decreases from 2.74% to 1.82%, 1.69% to 1.22%, and 1.23 MJ/kg to 0.85 MJ/kg, respectively. Meanwhile, the corresponding average relative error of the predicted samples is reduced from 8.3% to 5.48%, 5.83% to 4.42%, and 5.4% to 3.68%, respectively. The enhanced levels of accuracy obtained with the SVR combined with PCA based calibration models open up avenues for prospective prediction in coal properties.

  7. The analyzing power Asub(y)[(theta) for 12C(n,nsub(0,1))12C betwen 8.9 and] 14.9 MeV neutron energy

    International Nuclear Information System (INIS)

    Woye, E.; Tornow, W.; Mack, G.; Clegg, T.B.; Wylie, W.

    1983-01-01

    The analyzing power Asub(#betta#)(theta) for 12 C(n,n) 12 C elastic scattering and for inelastic scattering to the first excited state (Jsup(π) = 2 + , Q = -4.44 MeV) of 12 C was measured in the energy range from 8.9 to 14.9 MeV in 1 MeV steps. A pulsed polarized neutron beam was produced via the 2 H(d vector,n vector) 3 He polarization transfer reaction. Monte Carlo simulations were used to correct the data for finite geometry and multiple scattering effects. The Asub(#betta#) data, together with publsihed cross-section data, were analyzed in the framework of the spherical optical model and in the coupled-channels formalism. A good description of the data has been achieved. (orig.)

  8. Analyzing Potential Grid Impacts from Future In-Motion Roadway Wireless Power Transfer Scenarios: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meintz, Andrew; Gonder, Jeffrey; Jorgenson, Jennie; Brooker, Aaron

    2016-08-01

    This work examines the grid impact of in-motion roadway wireless power transfer through the examination of the electrification of high-capacity roadways inside a metropolitan area. The work uses data from a regional travel study and the Federal Highway Administration's Highway Performance Monitoring System to estimate the electrified roadway's hourly power use throughout a week. The data are then combined with hourly grid load estimates for the same metropolitan area to determine the overlay of traditional grid load with additional load from a future electrified roadway.

  9. Set-up with electrostatic analyzer for mass spectrometers

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Sysoev, A.A.; Samsonov, G.A.

    1977-01-01

    An attachment with an electrostatic analyzer that enables to implement a double focusing of ion beams when used in conjunction with a magnetic analyzer, is suggested. Used as the electrostatic analyzer is a cylindrical capacitor placed in a vacuum chamber. Apart from this, the attachment includes a vacuum pump, a nitrogen trap, a battery supply unit, one-beam ion receivers and a bellows inlet for capacitor adjustment. All assemblies and parts of the attachment are made of stainless steel. The test of a combined operation of the mass-spactrometer and the attachment indicate that the use of the attachment enables the utilization of sources which form ion beams with an energy dispersion of up to 1.5%, the mass-spectrometer resolving power being unchanged

  10. Nonlinear single-spin spectrum analyzer.

    Science.gov (United States)

    Kotler, Shlomi; Akerman, Nitzan; Glickman, Yinnon; Ozeri, Roee

    2013-03-15

    Qubits have been used as linear spectrum analyzers of their environments. Here we solve the problem of nonlinear spectral analysis, required for discrete noise induced by a strongly coupled environment. Our nonperturbative analytical model shows a nonlinear signal dependence on noise power, resulting in a spectral resolution beyond the Fourier limit as well as frequency mixing. We develop a noise characterization scheme adapted to this nonlinearity. We then apply it using a single trapped ion as a sensitive probe of strong, non-Gaussian, discrete magnetic field noise. Finally, we experimentally compared the performance of equidistant vs Uhrig modulation schemes for spectral analysis.

  11. INCA: method of analyzing in-core detector data in power reactors

    International Nuclear Information System (INIS)

    Ober, T.G.; Terney, W.B.; Marks, G.H.

    1975-04-01

    A method (INCA) is described by which signals from fixed in-core detectors are related to estimates of the three dimensional power distribution in an operating reactor core and to the maximum linear heat rate in the core. A description of the large library of data accompanying the method is provided. A detailed examination of the analytical verifications performed using the method is presented, and a summary of the uncertainty associated with the method is given. The uncertainty assigned to the maximum linear heat rate inferred by the method from operating reactor data is found to be 5.8 percent at a 95/95 confidence level. (U.S.)

  12. Analyzer of neutron flux in real time

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Carrillo M, R.A.; Balderas, E.G.

    1999-01-01

    With base in the study of the real signals of neutron flux of instability events occurred in the Laguna Verde nuclear power plant where the nucleus oscillation phenomena of the reactor are in the 0 to 2.5 Hz range, it has been seen the possibility about the development a surveillance and diagnostic equipment capable to analyze in real time the behavior of nucleus in this frequencies range. An important method for surveillance the stability of the reactor nucleus is the use of the Power spectral density which allows to determine the frequencies and amplitudes contained in the signals. It is used an instrument carried out by LabVIEW graphic programming with a data acquisition card of 16 channels which works at Windows 95/98 environment. (Author)

  13. Development of the nuclear plant analyzer for Korean standard Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Shin Hwan; Kim, Hyeong Heon; Song, In Ho; Hong, Eon Yeong; Oh, Yeong Taek [Korea Power Engineering Company Inc., Yongin (Korea, Republic of)

    2000-12-15

    The purpose of this study is to develop an NPA for the Ulchin Nuclear Power Plant Unit 3 and 4, the first KSNP type plant. In this study, the process model simulating the overall plant systems, GUI and simulation executive which provide the functions of an engineering simulator were developed, and the NPA was completed by integrating them. The contents and the scope of this study are as follows : main feedwater system, auxiliary feedwater system, Chemical and Volume Control System(CVCS), Safety Injection System(SIS), Shutdown Cooling System(SCS), electric power supply system, Core Protection Calculator(CPC), various plant control system, development of the graphics screens for each system, real-time simulation, simulation control for the enhancement of functional capabilities, user friendly GUI, collection of the design and operating data, establishment of the NPA database, integration of the GUI and simulation control program with process model, collection of the data for the verification and validation of the developed NPA, collection of the plant test data, collection and review of the results of other computer codes, verification of the simulation accuracy by comparing the NPA results with the actual plant data, validation of the simulation capability of the NPA, comparison against available data from other analysis suing different computer codes.

  14. Improved proton-deuteron phase-shift analysis above the deuteron breakup threshold and the three-nucleon analyzing-power puzzle

    CERN Document Server

    Tornow, W; Witala, H

    2002-01-01

    Using the existing high-accuracy data for proton-deuteron and deuteron-proton elastic scattering, a phase-shift analysis has been performed in the laboratory proton energy range from E sub p = 4 to 10 MeV The AV 18-based proton-deuteron phase shifts were used as starting values in the phase-shift search procedure. The low-partial wave phase shifts, especially the sup 4 P sub j phase shifts have been determined very precisely, thus providing valuable guidance for theoretical approaches to tackle the quest for a successful description of three-nucleon bound-state and continuum observables in a more efficient and consistent way. Furthermore, it was found that the sup 4 P sub 1 sub / sub 2 phase shift and the mixing parameter epsilon sub 3 sub / sub 2 sub sup - determined in the present analysis cannot be generated by sup 3 P sub j nucleon-nucleon interactions which are consistent with two-nucleon analyzing power data. Therefore, three-nucleon forces must play an essential role in resolving the long-standing thre...

  15. [Macromolecular aromatic network characteristics of Chinese power coal analyzed by synchronous fluorescence and X-ray diffraction].

    Science.gov (United States)

    Ye, Cui-Ping; Feng, Jie; Li, Wen-Ying

    2012-07-01

    Coal structure, especially the macromolecular aromatic skeleton structure, has a strong influence on coke reactivity and coal gasification, so it is the key to grasp the macromolecular aromatic skeleton coal structure for getting the reasonable high efficiency utilization of coal. However, it is difficult to acquire their information due to the complex compositions and structure of coal. It has been found that the macromolecular aromatic network coal structure would be most isolated if small molecular of coal was first extracted. Then the macromolecular aromatic skeleton coal structure would be clearly analyzed by instruments, such as X-ray diffraction (XRD), fluorescence spectroscopy with synchronous mode (Syn-F), Gel permeation chromatography (GPC) etc. Based on the previous results, according to the stepwise fractional liquid extraction, two Chinese typical power coals, PS and HDG, were extracted by silica gel as stationary phase and acetonitrile, tetrahydrofuran (THF), pyridine and 1-methyl-2-pyrollidinone (NMP) as a solvent group for sequential elution. GPC, Syn-F and XRD were applied to investigate molecular mass distribution, condensed aromatic structure and crystal characteristics. The results showed that the size of aromatic layers (La) is small (3-3.95 nm) and the stacking heights (Lc) are 0.8-1.2 nm. The molecular mass distribution of the macromolecular aromatic network structure is between 400 and 1 130 amu, with condensed aromatic numbers of 3-7 in the structure units.

  16. Comparisons of vector analyzing-power data and calculations for neutron-deuteron elastic scattering from 10 to 14 MeV

    International Nuclear Information System (INIS)

    Howell, C.R.; Tornow, W.; Murphy, K.; Pfuetzner, H.G.; Roberts, M.L.; Li, A.; Felsher, P.D.; Walter, R.L.; Slaus, I.; Treado, P.A.; Koike, Y.

    1987-01-01

    High-accuracy analyzing-power A y (θ) data for n-d elastic scattering at 12 MeV have been measured using the polarized-neutron facilities at the Triangle Universities Nuclear Laboratory (TUNL). The present data have been combined with previous n-d measurements at 10, 12, and 14.1 MeV to form the highest-accuracy A y (θ) data set for n-d elastic scattering below 20 MeV. These data are compared to recent Faddeev-based neutron-deuteron (n-d) calculations which use the Paris and Bonn equivalent separable potentials PEST and BEST, as well as Doleschall's representation of the P- and D-wave nucleon-nucleon interactions. None of these models adequately describe the data in the angular region around the maximum of A y (θ). Possible reasons for the discrepancies are discussed. The sensitivity of the present Faddeev-based calculations to various angular momentum components of the nucleon-nucleon interaction are examined. (Auth.)

  17. Development of a Simulation Framework for Analyzing Security of Supply in Integrated Gas and Electric Power Systems

    Directory of Open Access Journals (Sweden)

    Kwabena Addo Pambour

    2017-01-01

    Full Text Available Gas and power networks are tightly coupled and interact with each other due to physically interconnected facilities. In an integrated gas and power network, a contingency observed in one system may cause iterative cascading failures, resulting in network wide disruptions. Therefore, understanding the impacts of the interactions in both systems is crucial for governments, system operators, regulators and operational planners, particularly, to ensure security of supply for the overall energy system. Although simulation has been widely used in the assessment of gas systems as well as power systems, there is a significant gap in simulation models that are able to address the coupling of both systems. In this paper, a simulation framework that models and simulates the gas and power network in an integrated manner is proposed. The framework consists of a transient model for the gas system and a steady state model for the power system based on AC-Optimal Power Flow. The gas and power system model are coupled through an interface which uses the coupling equations to establish the data exchange and coordination between the individual models. The bidirectional interlink between both systems considered in this studies are the fuel gas offtake of gas fired power plants for power generation and the power supply to liquefied natural gas (LNG terminals and electric drivers installed in gas compressor stations and underground gas storage facilities. The simulation framework is implemented into an innovative simulation tool named SAInt (Scenario Analysis Interface for Energy Systems and the capabilities of the tool are demonstrated by performing a contingency analysis for a real world example. Results indicate how a disruption triggered in one system propagates to the other system and affects the operation of critical facilities. In addition, the studies show the importance of using transient gas models for security of supply studies instead of successions of

  18. Implementing low power consumption in standby mode in the case of power supplies with power factor correction

    OpenAIRE

    Martín, Kevin; F., Pablo; G., Diego; Sebastián, Javier; Álvarez, Santiago

    2017-01-01

    This work analyzes different options to implement low power consumption in Switching Mode Power Supplies (SMPSs) with Power Factor Correction (PFC) when they are in standby mode. The standard SMPSs for power levels higher than 100 W are made up of two stages: a classical PFC stage based on a Boost Converter operating in the Continuous Conduction Mode and a second stage based on any type of isolated DC-DC converter. The value of the resistive sensors needed by the PFC control stage determines ...

  19. Revised sequence components power system models for unbalanced power system studies

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Akher, M. [Tunku Abdul Rahman Univ., Kuala Lumpur (Malaysia); Nor, K.-M. [Univ. of Technology Malaysia, Johor (Malaysia); Rashid, A.H.A. [Univ. of Malaya, Kuala Lumpur (Malaysia)

    2007-07-01

    The principle method of analysis using positive, negative, and zero-sequence networks has been used to examine the balanced power system under both balanced and unbalanced loading conditions. The significant advantage of the sequence networks is that the sequence networks become entirely uncoupled in the case of balanced three-phase power systems. The uncoupled sequence networks then can be solved in independent way such as in fault calculation programs. However, the hypothesis of balanced power systems cannot be considered in many cases due to untransposed transmission lines; multiphase line segments in a distribution power system; or transformer phase shifts which cannot be incorporated in the existing models. A revised sequence decoupled power system models for analyzing unbalanced power systems based on symmetrical networks was presented in this paper. These models included synchronous machines, transformers, transmission lines, and voltage regulators. The models were derived from their counterpart's models in phase coordinates frame of reference. In these models, the three sequence networks were fully decoupled with a three-phase coordinates features such as transformer phase shifts and transmission line coupling. The proposed models were used to develop an unbalanced power-flow program for analyzing both balanced and unbalanced networks. The power flow solution was identical to results obtained from a full phase coordinate three-phase power-flow program. 11 refs., 3 tabs.

  20. Impact of Offshore Wind Power Integrated by VSC-HVDC on Power Angle Stability of Power Systems

    Science.gov (United States)

    Lu, Haiyang; Tang, Xisheng

    2017-05-01

    Offshore wind farm connected to grid by VSC-HVDC loses frequency support for power system, so adding frequency control in wind farm and VSC-HVDC system is an effective measure, but it will change wind farm VSC-HVDC’s transient stability on power system. Through theoretical analysis, concluding the relationship between equivalent mechanical power and electromagnetic power of two-machine system with the active power of wind farm VSC-HVDC, then analyzing the impact of wind farm VSC-HVDC with or without frequency control and different frequency control parameters on angle stability of synchronous machine by EEAC. The validity of theoretical analysis has been demonstrated through simulation in PSCAD/EMTDC.

  1. Research on a Small Signal Stability Region Boundary Model of the Interconnected Power System with Large-Scale Wind Power

    Directory of Open Access Journals (Sweden)

    Wenying Liu

    2015-03-01

    Full Text Available For the interconnected power system with large-scale wind power, the problem of the small signal stability has become the bottleneck of restricting the sending-out of wind power as well as the security and stability of the whole power system. Around this issue, this paper establishes a small signal stability region boundary model of the interconnected power system with large-scale wind power based on catastrophe theory, providing a new method for analyzing the small signal stability. Firstly, we analyzed the typical characteristics and the mathematic model of the interconnected power system with wind power and pointed out that conventional methods can’t directly identify the topological properties of small signal stability region boundaries. For this problem, adopting catastrophe theory, we established a small signal stability region boundary model of the interconnected power system with large-scale wind power in two-dimensional power injection space and extended it to multiple dimensions to obtain the boundary model in multidimensional power injection space. Thirdly, we analyzed qualitatively the topological property’s changes of the small signal stability region boundary caused by large-scale wind power integration. Finally, we built simulation models by DIgSILENT/PowerFactory software and the final simulation results verified the correctness and effectiveness of the proposed model.

  2. Nuclear power economics

    International Nuclear Information System (INIS)

    Moynet, G.

    1987-01-01

    The economical comparison of nuclear power plants with coal-fired plants in some countries or areas are analyzed. It is not difficult to show that nuclear power will have a significant and expanding role to play in providing economic electricity in the coming decades. (Liu)

  3. A Comparison of a Solar Power Satellite Concept to a Concentrating Solar Power System

    Science.gov (United States)

    Smitherman, David V.

    2013-01-01

    A comparison is made of a solar power satellite (SPS) concept in geostationary Earth orbit to a concentrating solar power (CSP) system on the ground to analyze overall efficiencies of each infrastructure from solar radiance at 1 AU to conversion and transmission of electrical energy into the power grid on the Earth's surface. Each system is sized for a 1-gigawatt output to the power grid and then further analyzed to determine primary collector infrastructure areas. Findings indicate that even though the SPS concept has a higher end-to-end efficiency, the combined space and ground collector infrastructure is still about the same size as a comparable CSP system on the ground.

  4. Self-powered detectors for power reactors: an overview

    International Nuclear Information System (INIS)

    Ma, J.

    2006-01-01

    In this paper, Self-Powered Detectors (SPDs) for applications in nuclear power reactors have been reviewed. Based on their responses to radiation, these detectors can be divided into delayed response Self-Powered Neutron Detector (SPND), prompt response SPND and Self-Powered Gamma Detector (SPGD). The operational principles of these detectors are presented and their distinctive characteristics are examined accordingly. The analytical models and Monte Carlo method to calculate the responses of these detectors to neutron flux and external gamma rays are reviewed. The paper has also considered some related signal processing techniques, such as detector calibrations and detector signal compensations. Furthermore, a couple of failure modes have also been analyzed. Finally, applications of SPD in nuclear power reactors are summarized. (author)

  5. Self-powered detectors for power reactors: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J. [Univ. of Western Ontario, Dept. of Mechanical and Materials Engineering, London, Ontario (Canada)]. E-mail: jma64@uwo.ca

    2006-07-01

    In this paper, Self-Powered Detectors (SPDs) for applications in nuclear power reactors have been reviewed. Based on their responses to radiation, these detectors can be divided into delayed response Self-Powered Neutron Detector (SPND), prompt response SPND and Self-Powered Gamma Detector (SPGD). The operational principles of these detectors are presented and their distinctive characteristics are examined accordingly. The analytical models and Monte Carlo method to calculate the responses of these detectors to neutron flux and external gamma rays are reviewed. The paper has also considered some related signal processing techniques, such as detector calibrations and detector signal compensations. Furthermore, a couple of failure modes have also been analyzed. Finally, applications of SPD in nuclear power reactors are summarized. (author)

  6. Power in Bourdieu and Foucault: considerations about symbolic power and disciplinary power

    Directory of Open Access Journals (Sweden)

    Tiago Barros Rosa

    2017-06-01

    Full Text Available This article aims to present some of conceptions about power, which are present in the thoughts of two contemporary classics from Social Science: Pierre Bourdieu and Michel Foucault. Most specifically, we will analyze the foundations of the notions of symbolic power and disciplinary power, developed, respectively, on their work. Despite the theoretical and methodological differences in both authors, we attend to approach the distinct notions of power in their scientific projects and to confront them to the currently dominant tendency, whose fundamental assumption are supported by the Weberian theory. The idea of imposition of will, as discussed in Weber’s classic formulation of power, brings in itself, indelibly, the awareness, calculation and intentionality by the social actors. Both Foucault and Bordieu, the individuals - subjects and social agents – are conditioned and constrained by external relation and forces, which are often not consciously perceived.

  7. Assessment method for analyzing and developing human resource management practices in nuclear power industry

    International Nuclear Information System (INIS)

    Maeki, E.; Pahkin, K.; Lindstroem, S.; Kurki, A-L.

    2014-01-01

    Implementation of HRM practices is often devolved from the HRM unit to front line managers and supervisors. However, the implementation of these practices by line managers and supervisors may vary significantly. They may, for example, be unaware of how to implement HRM practices or skeptical towards the effectiveness of the intended practices. Based on the literature, interviews and workshops in the nuclear power industry, a self-assessment method of HRM practices for intra-organizational use was developed. The assessment method was piloted in four nuclear power organizations. The assessment method seems to be a good tool for generating fruitful discussion on HRM practices, finding areas of HRM practices that need to be developed, and triggering peer-to-peer knowledge sharing and learning on HRM practices. (authors)

  8. Adaptive Reactive Power Control of PV Power Plants for Improved Power Transfer Capability under Ultra-Weak Grid Conditions

    DEFF Research Database (Denmark)

    Yang, Dongsheng; Wang, Xiongfei; Liu, Fangcheng

    2018-01-01

    with the unity power factor. Then, considering the reactive power compensation from PV inverters, the minimum SCR in respect to Power Factor (PF) is derived, and the optimized coordination of the active and reactive power is exploited. It is revealed that the power transfer capability of PV power plant under...... of a 200 MW PV power plant demonstrate that the proposed method can ensure the rated power transfer of PV power plant with the SCR of 1.25, provided that the PV inverters are operated with the minimal PF=0.9.......This paper analyzes the power transfer limitation of the PV power plant under the ultra-weak grid condition, i.e., when the Short-Circuit Ratio (SCR) is close to 1. It explicitly identifies that a minimum SCR of 2 is required for the PV power plant to deliver the rated active power when operating...

  9. Similarities and differences between conventional power and nuclear power

    International Nuclear Information System (INIS)

    Wang Yingrong

    2011-01-01

    As the implementation of the national guideline of 'proactively promoting nuclear power development', especially after China decided in 2006 to introduce Westinghouse's AP1000 technology, some of the power groups specialized in conventional power generation, have been participating in the preliminary work and construction of nuclear power projects in certain degrees. Meanwhile, such traditional nuclear power corporations as China National Nuclear Corporation (CNNC) and China Guangdong Nuclear Power Corporation (CGNPC) have also employed some employees with conventional power generation experience. How can these employees who have long been engaged in conventional power generation successfully adapt to the new work pattern, ideology, knowledge, thinking mode and proficiency of nuclear power, so that they can fit in with the work requirements of nuclear power and become qualified as soon as possible? By analyzing the technological, managerial and cultural features of nuclear power, as well as some issues to be kept in mind when engaged in nuclear power, this paper intends to make some contribution to the nuclear power development in the specific period. (author)

  10. Comparison of polarization and analyzing power for the /sup 15/N(p,n)/sup 15/O reaction

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, R.C.; Tornow, W.; Lisowski, P.W.; Murphy, K.; Walter, R.L. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA))

    1983-11-21

    The analyzing power Asub(y)(theta) and polarization Psup(y)(theta) for the /sup 15/N(p,n/sub 0/)/sup 15/O reaction have been measured for Esub(p)=4.5-11.3 MeV. The values of the two observables are nearly the same above 11 MeV, where a ''quasi-elastic'' view of the (p,n) reaction to the analog state should be applicable. Below 10 MeV, however, large spin-flip amplitudes and isospin-mixing ratios provide the two major conditions needed to obtain Psup(y)(theta)not=Asub(y)(theta) and dramatic differences between the two observables are observed. The size of the differences and their dependence on energy are similar to the results predicted by shell-model calculations. The Psup(y)(theta) and Asub(y)(theta) measurements have been combined with existing cross-section data to provide information about spin-flip processes. We also comment on the connection between comparisons of Psup(y)(theta) and Asup(y)(theta) in charge-symmetric (p,n) reactions and the recent controversial measurements of a difference between the values of Psup(y)(theta) for a reaction and Asub(y)(theta) for the inverse reaction.

  11. Mobile Greenhouse Gas Flux Analyzer for Unmanned Aerial Vehicles, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research (LGR) proposes to develop highly-accurate, lightweight, low-power gas analyzers for measurements of carbon dioxide (CO2) and water vapor (H2O)...

  12. Study on reactor power change and ambiguous control of third Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Wang Gongzhan

    2006-01-01

    The phenomenon of the average power reduction during long term full power operating in Third Qinshan nuclear power plant is analyzed . According to the basic conclusions of reactor power fluctuating derived by probability statistic and calculation the corresponding ambiguous control project is proposed. The operating performance could be achieved by the present controlling project is predicted additionally. (authors)

  13. A simplified approach to analyze the effectiveness of NO2 and SO2 emission reduction of coal-fired power plant from OMI retrievals

    Science.gov (United States)

    Bai, Yang; Wu, Lixin; Zhou, Yuan; Li, Ding

    2017-04-01

    Nitrogen oxides (NOX) and sulfur dioxide (SO2) emissions from coal combustion, which is oxidized quickly in the atmosphere resulting in secondary aerosol formation and acid deposition, are the main resource causing China's regional fog-haze pollution. Extensive literature has estimated quantitatively the lifetimes and emissions of NO2 and SO2 for large point sources such as coal-fired power plants and cities using satellite measurements. However, rare of these methods is suitable for sources located in a heterogeneously polluted background. In this work, we present a simplified emission effective radius extraction model for point source to study the NO2 and SO2 reduction trend in China with complex polluted sources. First, to find out the time range during which actual emissions could be derived from satellite observations, the spatial distribution characteristics of mean daily, monthly, seasonal and annual concentration of OMI NO2 and SO2 around a single power plant were analyzed and compared. Then, a 100 km × 100 km geographical grid with a 1 km step was established around the source and the mean concentration of all satellite pixels covered in each grid point is calculated by the area weight pixel-averaging approach. The emission effective radius is defined by the concentration gradient values near the power plant. Finally, the developed model is employed to investigate the characteristic and evolution of NO2 and SO2 emissions and verify the effectiveness of flue gas desulfurization (FGD) and selective catalytic reduction (SCR) devices applied in coal-fired power plants during the period of 10 years from 2006 to 2015. It can be observed that the the spatial distribution pattern of NO2 and SO2 concentration in the vicinity of large coal-burning source was not only affected by the emission of coal-burning itself, but also closely related to the process of pollutant transmission and diffusion caused by meteorological factors in different seasons. Our proposed

  14. Analyzing power Asub(y)((theta) for /sup 12/C(n,nsub(0,1))/sup 12/C betwen 8. 9 and) 14. 9 MeV neutron energy

    Energy Technology Data Exchange (ETDEWEB)

    Woye, E.; Tornow, W.; Mack, G. (Tuebingen Univ. (Germany, F.R.). Physikalisches Inst.); Floyd, C.E.; Guss, P.P.; Murphy, K.; Byrd, R.C.; Wender, S.A.; Walter, R.L. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA))

    1983-02-01

    The analyzing power Asub(..gamma..)(theta) for /sup 12/C(n,n)/sup 12/C elastic scattering and for inelastic scattering to the first excited state (Jsup(..pi..) = 2/sup +/, Q = -4.44 MeV) of /sup 12/C was measured in the energy range from 8.9 to 14.9 MeV in 1 MeV steps. A pulsed polarized neutron beam was produced via the /sup 2/H(d vector,n vector)/sup 3/He polarization transfer reaction. Monte Carlo simulations were used to correct the data for finite geometry and multiple scattering effects. The Asub(..gamma..) data, together with publsihed cross-section data, were analyzed in the framework of the spherical optical model and in the coupled-channels formalism. A good description of the data has been achieved.

  15. High rate spectroscopy for on-line nuclear coal analyzer (Nucoalyzer)

    International Nuclear Information System (INIS)

    McQuaid, J.H.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    A high count rate, time-variant Ge(Li) spectrometer has been developed for on-line coal analysis. The analyzer is being fabricated for use in a power generating station. Prompt neutron activation of coal samples is the basis of analysis, with 252 Cf as the source for irradiation. The spectroscopy system allows counting rates up to 150 k counts per second without significant loss in energy resolution or peak shape. The high data throughput allows the coal analyzer to be used for on-line process control. The coal analyzer will be discussed, with emphasis on the high-rate signal processing system. Results of analysis of coal samples will be presented

  16. Operating experience feedback on lose of offsite power supply for nuclear power plant

    International Nuclear Information System (INIS)

    Jiao Feng; Hou Qinmai; Che Shuwei

    2013-01-01

    The function of the service power system of a nuclear power plant is to provide safe and reliable power supply for the nuclear power plant facilities. The safety of nuclear power plant power supply is essential for nuclear safety. The serious accident of Fukushima Daiichi nuclear power plant occurred due to loss of service power and the ultimate heat sink. The service power system has two independent offsite power supplies as working power and auxiliary power. This article collected events of loss of offsite power supply in operating nuclear power plants at home and abroad, and analyzed the plant status and cause of loss of offsite power supply events, and proposed improvement measures for dealing with loss of offsite power supply. (authors)

  17. SEAscan 3.5: A simulator performance analyzer

    International Nuclear Information System (INIS)

    Dennis, T.; Eisenmann, S.

    1990-01-01

    SEAscan 3.5 is a personal computer based tool developed to analyze the dynamic performance of nuclear power plant training simulators. The system has integrated features to provide its own human featured performance. In this paper, the program is described as a tool for the analysis of training simulator performance. The structure and operating characteristics of SEAscan 3.5 are described. The hardcopy documents are shown to aid in verification of conformance to ANSI/ANS-3.5-1985

  18. Design of multi-channel amplitude analyzer base on LonWorks

    International Nuclear Information System (INIS)

    Zhang Ying; Zhao Lihong; Chen Aihua

    2008-01-01

    The paper introduces the multi-channel analyzer which adopts LonWorks technology. The system detects the pulse peak by hardware circuits and controls data acquisition and network communication by Micro Controller and Unit and Neuron chip. SCM is programmed by Keil C51; the communication between SCM and nerve cell is realized by Neron C language, and the computer program is written by VB language. Test results show that this analyzer is with fast conversion speed and low power consumption. (authors)

  19. Fractals in Power Reactor Noise

    International Nuclear Information System (INIS)

    Aguilar Martinez, O.

    1994-01-01

    In this work the non- lineal dynamic problem of power reactor is analyzed using classic concepts of fractal analysis as: attractors, Hausdorff-Besikovics dimension, phase space, etc. A new non-linear problem is also analyzed: the discrimination of chaotic signals from random neutron noise signals and processing for diagnosis purposes. The advantages of a fractal analysis approach in the power reactor noise are commented in details

  20. Accelerating nuclear power standards development and promoting sound nuclear power development in China

    International Nuclear Information System (INIS)

    Yang Changli

    2008-01-01

    The paper expounds the importance of quickening establishment and perfection of nuclear power standard system in China, analyzes achievements made and problems existed during the development of nuclear power standards, put forward proposals to actively promote the work in this regard, and indicates that CNNC will further strengthen the standardization work, enhance coordination with those trades related to nuclear power standards, and jointly promote the development of nuclear power standards. (authors)

  1. QA practice for online analyzers in water steam cycles

    International Nuclear Information System (INIS)

    Staub, L.

    2010-01-01

    The liberalization of power markets throughout the world has resulted in more and more power stations being operated in cycling mode, with frequent load changes and multiple daily start-up and shut-down cycles. This more flexible operation also calls for better automation and poses new challenges to water chemistry in water steam cycles, to avoid subsequent damage to vital plant components such as turbines, boilers or condensers. But automation for the most important chemistry control tool, the sampling and online analyzer system, is only possible if chemists can rely on their online analysis equipment. Proof of plausibility as well as reliability and availability of online analysis results becomes a major focus. While SOP and standard QA procedures for laboratory equipment are well established and daily practice, such measures are widely neglected for online process analyzers. This paper is aiming to establish a roadmap for the implementation of SOP and QA/QC procedures for online instruments in water steam cycles, leading to reliable chemical information that is trustworthy for process automation and chemistry control in water steam cycles. (author)

  2. QA practice for online analyzers in water steam cycles

    International Nuclear Information System (INIS)

    Staub Lukas

    2009-01-01

    The liberalization of power markets throughout the world has resulted in more and more power stations being operated in cycling mode, with frequent load changes and multiple daily start-up and shut-down cycles. This more flexible operation also calls for better automation and poses new challenges to water chemistry in water steam cycles, to avoid subsequent damage to vital plant components such as turbines, boilers or condensers. But automation for the most important chemistry control tool, the sampling and online analyzer system, is only possible if chemists can rely on their online analysis equipment. Proof of plausibility as well as reliability and availability of online analysis results becomes a major focus. While SOP and standard QA procedures for laboratory equipment are well established and daily practice, such measures are widely neglected for online process analyzers. This paper is aiming to establish a roadmap for the implementation of SOP and QA/QC procedures for online instruments in water steam cycles, leading to reliable chemical information that is trustworthy for process automation and chemistry control in water steam cycles. (author)

  3. Compact Microwave Fourier Spectrum Analyzer

    Science.gov (United States)

    Savchenkov, Anatoliy; Matsko, Andrey; Strekalov, Dmitry

    2009-01-01

    A compact photonic microwave Fourier spectrum analyzer [a Fourier-transform microwave spectrometer, (FTMWS)] with no moving parts has been proposed for use in remote sensing of weak, natural microwave emissions from the surfaces and atmospheres of planets to enable remote analysis and determination of chemical composition and abundances of critical molecular constituents in space. The instrument is based on a Bessel beam (light modes with non-zero angular momenta) fiber-optic elements. It features low power consumption, low mass, and high resolution, without a need for any cryogenics, beyond what is achievable by the current state-of-the-art in space instruments. The instrument can also be used in a wide-band scatterometer mode in active radar systems.

  4. Economic analysis of power generation from floating solar chimney power plant

    International Nuclear Information System (INIS)

    Zhou, Xinping; Yang, Jiakuan; Xiao, Bo; Wang, Fen

    2009-01-01

    Solar chimney thermal power technology that has a long life span is a promising large-scale solar power generating technology. This paper performs economic analysis of power generation from floating solar chimney power plant (FSCPP) by analyzing cash flows during the whole service period of a 100 MW plant. Cash flows are influenced by many factors including investment, operation and maintenance cost, life span, payback period, inflation rate, minimum attractive rate of return, non-returnable subsidy rate, interest rate of loans, sale price of electricity, income tax rate and whether additional revenue generated by carbon credits is included or not. Financial incentives and additional revenue generated by carbon credits can accelerate the development of the FSCPP. Sensitivity analysis to examine the effects of the factors on cash flows of a 100 MW FSCPP is performed in detail. The results show that the minimum price for obtaining minimum attractive rate of return (MARR) of 8% reaches 0.83 yuan (kWh) -1 under financial incentives including loans at a low interest rate of 2% and free income tax. Comparisons of economics of the FSCPP and reinforced concrete solar chimney power plant or solar photovoltaic plant are also performed by analyzing their cash flows. It is concluded that FSCPP is in reality more economical than reinforced concrete solar chimney power plant (RCSCPP) or solar photovoltaic plant (SPVP) with the same power capacity. (author)

  5. Investigating power control in autonomous power systems with increasing wind power penetration

    Energy Technology Data Exchange (ETDEWEB)

    Margaris, Ioannis D. [National Technical Univ. of Athens (Greece). Electric Energy Systems Lab.; Hansen, Anca D.; Sorensen, Poul [Risoe National Laboratory, Roskilde (Denmark). Wind Energy Dept.; Hatziargyriou, Nikos D. [National Technical Univ. of Athens (Greece). Electric Energy Systems Lab.; Public Power Corporation S.A., Athens (Greece)

    2009-07-01

    Increasing levels of wind penetration in autonomous power systems has set intensively high standards with respect to wind turbine technology during the last years. Special features of non-interconnected power systems make security issues rather critical, as the operation of large wind farms like conventional power plants is becoming a necessity. This paper includes the study case of Rhodos island, in Greece, where rapidly increasing wind penetration has started to impose serious security issues for the immediate future. The scenarios studied here correspond to reference year of study 2012 and include wind farms with three different wind turbine technologies - namely Doubly Fed Induction Generator (DFIG), Permanent Magnet Synchronous Generator (PMSG) and Active Stall Induction Generator (ASIG) based wind turbines. Aggregated models of the wind farms are being used and results for different load cases are being analyzed and discussed. The ability of wind farms to assist in some of the power system control services traditionally carried out by conventional synchronous generation is being investigated and discussed. The power grid of the island, including speed governors and automatic voltage regulators, is simulated in the dedicated power system simulation program Power Factory from DIgSILENT. (orig.)

  6. A methodology for analyzing the detection and suppression of fires in nuclear power plants

    International Nuclear Information System (INIS)

    Siu, N.; Apostolakis, G.

    1986-01-01

    The assessment of the fire risk in nuclear power plants requires the analysis of fire scenarios within specified rooms. A methodology that integrates the fire protection features of a given room into an existing fire risk analysis framework is developed. An important component of this methodology is a model for the time required to detect and suppress a fire in a given room, called the ''hazard time.'' This model accounts for the reliability of fire detection and suppression equipment, as well as for the characteristics rates of the detection and suppression processes. Because the available evidence for fire detection and suppression in nuclear power plants is sparse and often qualitative, a second component of this methodology is a set of methods needed to employ imprecise information in a statistical analysis. These methods can be applied to a wide variety of problems

  7. Analyzing power in inclusive. pi. sup + and. pi. sup - production at high x sub F with a 200 GeV polarized proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D L; Bonner, B E; Buchanan, J A; Clement, J M; Corcoran, M D; Cranshaw, J; Nessi-Tedaldi, F; Nessi, M; Nguyen, C; Phillips, G C; Roberts, J B; Skeens, J; White, J L [T.W. Bonner Nuclear Lab., Rice Univ., Houston, TX (United States); Akchurin, N; Langland, J; Onel, Y [Dept. of Physics, Univ. of Iowa, Iowa City, IA (United States); Belikov, N I; Derevschikov, A A; Grachov, O A; Matulenko, Yu A; Meschanin, A P; Nurushev, S B; Patalakha, D I; Rykov, V L; Solovyanov, V L; Vasiliev, A N [Inst. of High Energy Physics, Serpukhov (USSR); Bystricky, J; Lehar, F; Lesquen, A de [CEN-Saclay, 91 - Gif-sur-Yvette (France); Cossairt, J D; Read, A L [Fermi National Accelerator Lab., Batavia, IL (United States); En' yo, H; Funahashi, H; Goto, Y; Imai, K; Itow, Y; Makino, S; Masaike, A; Miyake, K; Nagamine, T; Saito, N; Yamashita, S [Dept. of Physics, Kyoto Univ. (Japan); Grosnick, D P; Hill, D A; Lopiano, D; Ohashi, Y; Spinka, H; Stanek, R; FNAL E704 Collaboration

    1991-08-01

    The analyzing power in inclusive charged pion production has been measured using the 200 GeV Fermilab polarized proton beam. A striking dependence in {chi}{sub F} is observed in which A{sub N} increases from 0 to 0.42 with increasing {chi}{sub F} for the {pi}{sup +} data and decreases from 0 to -0.38 with increasing {chi}{sub F} for {pi}{sup -} data. The kinematic range covered is 0.2{<=}{chi}{sub F}{<=}0.9 and 0.2{<=}p{sub T}{<=}2.0 GeV/c. In a simple model our data indicate that at large {chi}{sub F} the transverse spin of the proton is correlated with that of its quark constituents. (orig.).

  8. Real-time wavelet-transform spectrum analyzer for the investigation of 1/fα noise

    Science.gov (United States)

    Brogioli, Doriano; Vailati, Alberto

    2003-04-01

    A wavelet-transform spectrum analyzer operating in real time within the frequency range 3×10-5-1.3×105Hz has been implemented on a low-cost digital signal processing (DSP) board operating at 150 MHz. The wavelet decomposition of the signal allows one to efficiently process nonstationary signals dominated by large amplitude events fairly well localized in time, thus providing the natural tool to analyze processes characterized by 1/fα power spectrum. The parallel architecture of the DSP allows the real-time processing of the wavelet transform of the signal sampled at 0.3 MHz. The bandwidth is about 220 dB, almost 10 decades. The power spectrum of the signal is processed in real time from the mean square value of the wavelet coefficients within each frequency band. The performances of the spectrum analyzer have been investigated by performing dynamic light scattering experiments on colloidal suspensions and by comparing the measured spectra with the correlation functions data obtained with a traditional multitau correlator. In order to assess the potentialities of the spectrum analyzer in the investigation of processes involving a wide range of time scales, we have performed measurements on a model system where fluctuations in the scattered intensities are generated by the number fluctuations in a dilute colloidal suspension illuminated by a wide beam. This system is characterized by a power-law spectrum with exponent -3/2 in the scattered intensity fluctuations. The spectrum analyzer allows one to recover the power spectrum with a dynamic range spanning about 8 decades. The advantages of wavelet analysis versus correlation analysis in the investigation of processes characterized by a wide distribution of time scales and nonstationary processes are briefly discussed.

  9. Design and calibration of a fast-time resolution charge exchange analyzer

    International Nuclear Information System (INIS)

    Scime, E.; Hokin, S.

    1992-04-01

    A five channel, fast time resolution, scanning charge exchange analyzer has been developed for the Madison Symmetric Torus (MST). The analyzer consists of an iron vacuum vessel, a gas stripping cell, an electrostatic bending field, and five continuous electron multiplier detectors. The incident neutral flux and operation of the detectors in current mode limits the time resolution of the analyzer to 10 μs. The analyzer was absolutely calibrated over the energy range of interest (500--2000 eV) with an H + beam, so that the charge exchange power loss could also be measured. The analyzer can be swiveled on a shot-to-shot basis for measurements of T i (r), where 0.3 < r/a < 0.7. The mechanical design was driven by the need for a low cost, expandable ion temperature diagnostic

  10. On Variable Reverse Power Flow-Part I: Active-Reactive Optimal Power Flow with Reactive Power of Wind Stations

    Directory of Open Access Journals (Sweden)

    Aouss Gabash

    2016-02-01

    Full Text Available It has recently been shown that using battery storage systems (BSSs to provide reactive power provision in a medium-voltage (MV active distribution network (ADN with embedded wind stations (WSs can lead to a huge amount of reverse power to an upstream transmission network (TN. However, unity power factors (PFs of WSs were assumed in those studies to analyze the potential of BSSs. Therefore, in this paper (Part-I, we aim to further explore the pure reactive power potential of WSs (i.e., without BSSs by investigating the issue of variable reverse power flow under different limits on PFs in an electricity market model. The main contributions of this work are summarized as follows: (1 Introducing the reactive power capability of WSs in the optimization model of the active-reactive optimal power flow (A-R-OPF and highlighting the benefits/impacts under different limits on PFs. (2 Investigating the impacts of different agreements for variable reverse power flow on the operation of an ADN under different demand scenarios. (3 Derivation of the function of reactive energy losses in the grid with an equivalent-π circuit and comparing its value with active energy losses. (4 Balancing the energy curtailment of wind generation, active-reactive energy losses in the grid and active-reactive energy import-export by a meter-based method. In Part-II, the potential of the developed model is studied through analyzing an electricity market model and a 41-bus network with different locations of WSs.

  11. Simulations of the recent LaSalle-2 incident with the BNL plant analyzer

    International Nuclear Information System (INIS)

    Cheng, H.S.; Mallen, A.N.; Wulff, W.

    1989-01-01

    This paper presents the results of simulations of the recent power oscillation incident at the LaSalle-2 nuclear power plant using the BNL plant analyzer. The causes of the oscillation were investigated and the sensitivity of the oscillation to key parameters was studied. It is concluded that the observed power oscillation was caused by boiling instability (i.e., density wave oscillation) reinforced by the reactivity feedback in neutron kinetics, and that the density wave oscillation resulted from flow reduction due to recirculation pump trip and feedwater temperature reduction due to partial loss of feedwater heating capability as well as power peaking

  12. Power Curve Measurements

    DEFF Research Database (Denmark)

    Federici, Paolo; Vesth, Allan

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine....

  13. Power Curve Measurements

    DEFF Research Database (Denmark)

    Villanueva, Héctor; Gómez Arranz, Paula

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine...

  14. Analyzing the topological, electrical and reliability characteristics of a power transmission system for identifying its critical elements

    International Nuclear Information System (INIS)

    Zio, E.; Golea, L.R.

    2012-01-01

    The subject of this paper is the analysis of an electrical transmission system with the objective of identifying its most critical elements with respect to failures and attacks. The methodological approach undertaken is based on graph-theoretical (topological) network analysis. Four different perspectives of analysis are considered within the formalism of weighed networks, adding to the purely topological analysis of the system, the reliability and electrical characteristics of its components. In each phase of the analysis: i) a graph-theoretical representation is offered to highlight the structure of the most important system connections according to the particular characteristics examined (topological, reliability, electrical or electrical-reliability), ii) the classical degree index of a network node is extended to account for the different characteristics considered. The application of these concepts of analysis to an electrical transmission system of literature confirms the importance of different perspectives of analysis on such a critical infrastructure. - Highlights: ► We analyze a power system from topological, reliability and electrical perspectives. ► We rank critical components within a vulnerability assessment framework. ► We compute an extended degree to rank critical energy paths. ► We compare several analytical approaches and provide a table for choosing among them. ► We suggest network changes to increase the reliability of highly loaded energy paths.

  15. Development of a Simulation Framework for Analyzing Security of Supply in Integrated Gas and Electric Power Systems

    NARCIS (Netherlands)

    Pambour, Kwabena Addo; Erdener, Burcin Cakir; Bolado-Lavin, Ricardo; Dijkema, Gerhard

    2017-01-01

    Gas and power networks are tightly coupled and interact with each other due to physically interconnected facilities. In an integrated gas and power network, a contingency observed in one system may cause iterative cascading failures, resulting in network wide disruptions. Therefore, understanding

  16. Critical channel power calculation for nominal operation in the CNE (Embalse nuclear power plant): sensitivity study

    International Nuclear Information System (INIS)

    Garcia, A.E.; Parkansky, D.G.

    1993-01-01

    In the Embalse nuclear power plant (CNE), the Regional Overpower Protection System acting on the Shutdown Systems number 1 and number 2 protects the reactor against overpowers in the reactor field for a localized peaking or a power increase in the reactor as a whole. This report summarizes the results of the critical channel power calculation for the time average powers configuration for the 380 reactor field channels. The final purpose of this work is to analyze and eventually modify the detector set points. Other reactor configurations are being analyzed. The report also presents a sensitivity analysis in order to evaluate potential sources of error and uncertainties which could affect the ROP performance. (author)

  17. Research on key techniques in portable XRF analyzers

    International Nuclear Information System (INIS)

    Li Guodong; Jia Wenyi; Zhou Rongsheng; Tang Hong

    1999-01-01

    Focused on the problems of low sensitivity, poor detection limits, small number of determined elements and poor ability of matrix effect correction of the current field-portable X-ray fluorescence (XRF) analyzers, research work on key units of excitation source, detector, measurement circuit and microcomputerization is carried out. A miniature, low power X-ray tube excitation source is developed. A low dissipative 1024 channel analyzer, fitting to high resolution detectors, is prepared. Microcomputerization based on a notebook computer is realized. On the basis, a field, highly sensitive XRF system is constituted. With this system, multielements can be determined with the detection limits of less than 20 μg/g for the elements with medium or lower atomic numbers, one order of magnitude or more lower than those of the current portable XRF analyzers. The capabilities for matrix effect correction and data processing are enhanced. This system gets rid of radionuclide sources, making its use and carry safe and convenient

  18. Active Power Controls from Wind Power: Bridging the Gaps

    Energy Technology Data Exchange (ETDEWEB)

    Ela, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gevorgian, V. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fleming, P. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Zhang, Y. C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muljadi, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Scholbrook, A. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Aho, J. [Univ. of Colorado, Boulder, CO (United States); Buckspan, A. [Univ. of Colorado, Boulder, CO (United States); Pao, L. [Univ. of Colorado, Boulder, CO (United States); Singhvi, V. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Tuohy, A. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Pourbeik, P. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Brooks, D. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Bhatt, N. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States)

    2014-01-01

    This paper details a comprehensive study undertaken by the National Renewable Energy Laboratory, Electric Power Research Institute, and the University of Colorado to understand how the contribution of wind power providing active power control (APC) can benefit the total power system economics, increase revenue streams, improve the reliability and security of the power system, and provide superior and efficient response while reducing any structural and loading impacts that may reduce the life of the wind turbine or its components. The study includes power system simulations, control simulations, and actual field tests using turbines at NREL's National Wind Technology Center (NWTC). The study focuses on synthetic inertial control, primary frequency control, and automatic generation control, and analyzes timeframes ranging from milliseconds to minutes to the lifetime of wind turbines, locational scope ranging from components of turbines to large wind plants to entire synchronous interconnections, and additional topics ranging from economics to power system engineering to control design.

  19. Energy dependence of the analyzing power Ayo in the anti p p elastic scattering

    International Nuclear Information System (INIS)

    Bertini, R.

    1991-01-01

    The analysing power data A yo of the anti p p elastic scattering at six beam momenta from P lab = 439 MeV/c up to 988 MeV/c are plotted as a function of In(-t). The regularities shown by the data are discussed

  20. Analyzing Big Data in Psychology: A Split/Analyze/Meta-Analyze Approach

    Directory of Open Access Journals (Sweden)

    Mike W.-L. Cheung

    2016-05-01

    Full Text Available Big data is a field that has traditionally been dominated by disciplines such as computer science and business, where mainly data-driven analyses have been performed. Psychology, a discipline in which a strong emphasis is placed on behavioral theories and empirical research, has the potential to contribute greatly to the big data movement. However, one challenge to psychologists – and probably the most crucial one – is that most researchers may not have the necessary programming and computational skills to analyze big data. In this study we argue that psychologists can also conduct big data research and that, rather than trying to acquire new programming and computational skills, they should focus on their strengths, such as performing psychometric analyses and testing theories using multivariate analyses to explain phenomena. We propose a split/analyze/meta-analyze approach that allows psychologists to easily analyze big data. Two real datasets are used to demonstrate the proposed procedures in R. A new research agenda related to the analysis of big data in psychology is outlined at the end of the study.

  1. Analyzing Big Data in Psychology: A Split/Analyze/Meta-Analyze Approach.

    Science.gov (United States)

    Cheung, Mike W-L; Jak, Suzanne

    2016-01-01

    Big data is a field that has traditionally been dominated by disciplines such as computer science and business, where mainly data-driven analyses have been performed. Psychology, a discipline in which a strong emphasis is placed on behavioral theories and empirical research, has the potential to contribute greatly to the big data movement. However, one challenge to psychologists-and probably the most crucial one-is that most researchers may not have the necessary programming and computational skills to analyze big data. In this study we argue that psychologists can also conduct big data research and that, rather than trying to acquire new programming and computational skills, they should focus on their strengths, such as performing psychometric analyses and testing theories using multivariate analyses to explain phenomena. We propose a split/analyze/meta-analyze approach that allows psychologists to easily analyze big data. Two real datasets are used to demonstrate the proposed procedures in R. A new research agenda related to the analysis of big data in psychology is outlined at the end of the study.

  2. Power Oscillation Damping from VSC-HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Eriksson, Robert; Goumalatsos, Spyridon

    2016-01-01

    The implementation of power oscillation damping service on offshore wind power plants connected to onshore grids by voltage-source-converter-based high voltage direct current transmission is discussed. Novel design guidelines for damping controllers on voltage-source converters and wind power plant...... regarding real wind power plants are discussed: 1) robustness against control/communication delays; 2) limitations due to mechanical resonances in wind turbine generators; 3) actual capability of wind power plants to provide damping without curtailing production; and 4) power-ramp rate limiters....... controllers are derived, using phasor diagrams and a test network model and are then verified on a generic power system model. The effect of voltage regulators is analyzed, which is important for selecting the most robust damping strategy. Furthermore, other often disregarded practical implementation aspects...

  3. Blood culture cross contamination associated with a radiometric analyzer

    International Nuclear Information System (INIS)

    Griffin, M.R.; Miller, A.D.; Davis, A.C.

    1982-01-01

    During a 9-day period in August 1980 in a New Jersey hospital, three pairs of consecutively numbered blood cultures from different patients were identified as positive for the same organism, for each pair, both cultures were positive in the same atmosphere, both organisms had the same sensitivities, and the second of each pair grew at least 2 days after the first and was the only positive blood culture obtained from the patient. When the hospital laboratory discontinued use of its radiometric culture analyzer for 15 days, no more consecutive pairs of positive cultures occurred. Subsequent use of the machine for 9 days with a new power unit but the original circuit boards resulted in one more similar consecutive pair (Staphylococcus epidermidis). After replacement of the entire power unit, there were no further such pairs. Examination of the machine by the manufacturer revealed a defective circuit board which resulted in inadequate needle sterilization. Laboratories which utilize radiometric analyzers should be aware of the potential for cross contamination. Recognition of such events requires alert microbiologists and infection control practitioners and a record system in the bacteriology laboratory designed to identify such clusters

  4. Multi-faceted data gathering and analyzing system

    International Nuclear Information System (INIS)

    Gustavson, D.B.; Rich, K.

    1977-10-01

    A low-cost general purpose data gathering and analyzing system based on a microprocessor, an interface to CAMAC, and a phone link to a time-sharing system was implemented. The parts cost for the microprocessor system was about $6000. The microprocessor buffers the data such that the variable response of the time-sharing system is acceptable for performing real-time data acquisition. The full power and flexibility of the time-sharing system excels at the task of on-line data analysis once this buffering problem is solved. 4 figures

  5. Axial power difference control strategy and computer simulation for GNPS during stretch-out and power decrease

    International Nuclear Information System (INIS)

    Liao Yehong; Xiao Min; Li Xianfeng; Zhu Minhong

    2004-01-01

    Successful control of the axial power difference for PWR is crucial to nuclear safety. After analyzing various elements' effect on the axial power distribution, different axial power deviation control strategies have been proposed to comply with different power decrease scenarios. Application of the strategy to computer simulation shows that our prediction of axial power deviation evolution is comparable to the measurement value, and that our control strategy is effective

  6. Assessment method for analyzing and developing human resource management practices in the nuclear power industry

    International Nuclear Information System (INIS)

    Maeki, Eerikki; Pahkin, Krista; Lindstroem, S.; Kurki, Anna-Leena

    2015-01-01

    Implementation of HRM practices is often devolved from the HRM unit to front line managers and supervisors. However, the implementation of these practices by line managers and supervisors may vary significantly. They may, for example, be unaware of how to implement HRM practices or sceptical towards the effectiveness of the intended practices. Based on the literature, interviews and workshops in the nuclear power industry, a self-assessment method of HRM practices for intra-organizational use was developed. The assessment method was piloted in four nuclear power organizations. The assessment method seems to be a good tool for generating fruitful discussion on HRM practices, finding areas of HRM practices that need to be developed, and triggering peer-to-peer knowledge sharing and learning on HRM practices.

  7. Assessment method for analyzing and developing human resource management practices in the nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Maeki, Eerikki [Aalto Univ. (Finland). Dept. of Industrial Engineering and Management; Pahkin, Krista; Lindstroem, S.; Kurki, Anna-Leena [Finnish Institue of Occupational Health, Helsinki (Finland). Centre of Expertise for the Development of Work and Organizations

    2015-04-15

    Implementation of HRM practices is often devolved from the HRM unit to front line managers and supervisors. However, the implementation of these practices by line managers and supervisors may vary significantly. They may, for example, be unaware of how to implement HRM practices or sceptical towards the effectiveness of the intended practices. Based on the literature, interviews and workshops in the nuclear power industry, a self-assessment method of HRM practices for intra-organizational use was developed. The assessment method was piloted in four nuclear power organizations. The assessment method seems to be a good tool for generating fruitful discussion on HRM practices, finding areas of HRM practices that need to be developed, and triggering peer-to-peer knowledge sharing and learning on HRM practices.

  8. Study on emergency power control strategy for AC/DC hybrid power system containing VSC-HVDC

    Science.gov (United States)

    Liu, Lin; Hu, Zhenda; Ye, Rong; Lin, Zhangsui; Yang, Xiaodong; Yi, Yang

    2018-04-01

    This paper presents a comprehensive emergency power control strategy for AC/DC hybrid power systems containing VSC-HVDC. Firstly, the paper analyzes the power support of the VSC-HVDC to the AC lines using the Power Transferring Relativity Factor (PTRF). Then the power adjustment of the VSC-HVDC in several different circumstances are calculated. Finally, the online power control strategies of VSC-HVDC are designed, which could rapidly control the power of the VSC-HVDC, keeping the power flow of AC lines below the upper limit. Furthermore, the strategy is proven to be effective by the simulations with EMTDC/PSCAD.

  9. Development of a Telemetric, Miniaturized Electrochemical Amperometric Analyzer.

    Science.gov (United States)

    Jung, Jaehyo; Lee, Jihoon; Shin, Siho; Kim, Youn Tae

    2017-10-23

    In this research, we developed a portable, three-electrode electrochemical amperometric analyzer that can transmit data to a PC or a tablet via Bluetooth communication. We performed experiments using an indium tin oxide (ITO) glass electrode to confirm the performance and reliability of the analyzer. The proposed analyzer uses a current-to-voltage (I/V) converter to convert the current generated by the reduction-oxidation (redox) reaction of the buffer solution to a voltage signal. This signal is then digitized by the processor. The configuration of the power and ground of the printed circuit board (PCB) layer is divided into digital and analog parts to minimize the noise interference of each part. The proposed analyzer occupies an area of 5.9 × 3.25 cm² with a current resolution of 0.4 nA. A potential of 0~2.1 V can be applied between the working and the counter electrodes. The results of this study showed the accuracy of the proposed analyzer by measuring the Ruthenium(III) chloride ( Ru III ) concentration in 10 mM phosphate-buffered saline (PBS) solution with a pH of 7.4. The measured data can be transmitted to a PC or a mobile such as a smartphone or a tablet PC using the included Bluetooth module. The proposed analyzer uses a 3.7 V, 120 mAh lithium polymer battery and can be operated for 60 min when fully charged, including data processing and wireless communication.

  10. Development of a Telemetric, Miniaturized Electrochemical Amperometric Analyzer

    Directory of Open Access Journals (Sweden)

    Jaehyo Jung

    2017-10-01

    Full Text Available In this research, we developed a portable, three-electrode electrochemical amperometric analyzer that can transmit data to a PC or a tablet via Bluetooth communication. We performed experiments using an indium tin oxide (ITO glass electrode to confirm the performance and reliability of the analyzer. The proposed analyzer uses a current-to-voltage (I/V converter to convert the current generated by the reduction-oxidation (redox reaction of the buffer solution to a voltage signal. This signal is then digitized by the processor. The configuration of the power and ground of the printed circuit board (PCB layer is divided into digital and analog parts to minimize the noise interference of each part. The proposed analyzer occupies an area of 5.9 × 3.25 cm2 with a current resolution of 0.4 nA. A potential of 0~2.1 V can be applied between the working and the counter electrodes. The results of this study showed the accuracy of the proposed analyzer by measuring the Ruthenium(III chloride ( Ru III concentration in 10 mM phosphate-buffered saline (PBS solution with a pH of 7.4. The measured data can be transmitted to a PC or a mobile such as a smartphone or a tablet PC using the included Bluetooth module. The proposed analyzer uses a 3.7 V, 120 mAh lithium polymer battery and can be operated for 60 min when fully charged, including data processing and wireless communication.

  11. A Methodology to Analyze Photovoltaic Tracker Uptime

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Matthew T [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ruth, Dan [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-17

    A metric is developed to analyze the daily performance of single-axis photovoltaic (PV) trackers. The metric relies on comparing correlations between the daily time series of the PV power output and an array of simulated plane-of-array irradiances for the given day. Mathematical thresholds and a logic sequence are presented, so the daily tracking metric can be applied in an automated fashion on large-scale PV systems. The results of applying the metric are visually examined against the time series of the power output data for a large number of days and for various systems. The visual inspection results suggest that overall, the algorithm is accurate in identifying stuck or functioning trackers on clear-sky days. Visual inspection also shows that there are days that are not classified by the metric where the power output data may be sufficient to identify a stuck tracker. Based on the daily tracking metric, uptime results are calculated for 83 different inverters at 34 PV sites. The mean tracker uptime is calculated at 99% based on 2 different calculation methods. The daily tracking metric clearly has limitations, but as there is no existing metrics in the literature, it provides a valuable tool for flagging stuck trackers.

  12. A matrix game model for analyzing FTR bidding strategies in deregulated electric power markets

    International Nuclear Information System (INIS)

    Das, Tapas K.; Rocha, Patricio; Babayigit, Cihan

    2010-01-01

    Suppliers in deregulated electric power markets compete for financial transmission rights (FTRs) to hedge against congestion charges. The system operator receives the bids for FTRs submitted by the suppliers and develops an allocation strategy by solving an optimization model. Each FTR bid is defined by a path, a quantity indicating the amount of FTRs the supplier is bidding for in that path, and the price that the supplier is willing to pay for each FTR. The FTR revenue is calculated only after the electricity market has been cleared by computing the differences in the LMPs at the pair of nodes that connect each path. Thus, suppliers rely on forecasts of locational marginal prices (LMPs) to develop their FTR bids. In this paper, we present a game theoretic modeling approach to develop FTR bidding strategies for power suppliers assuming that they have forecasts of LMPs. The game theoretic model considers multiple participants as well as network contingencies. We apply the game theoretic model on a sample network to assess impacts of variations of bid and network parameters on the FTR market outcome. (author)

  13. Power generation

    International Nuclear Information System (INIS)

    Nunez, Anibal D.

    2001-01-01

    In the second half of twentieth century, nuclear power became an industrial reality. Now the operating 433 power plants, the 37 plants under construction, near 9000 years/reactor with only one serious accident with emission of radioactive material to the environment (Chernobyl) show the maturity of this technology. Today nuclear power contribute a 17% to the global generation and an increase of 75 % of the demand of electricity is estimated for 2020 while this demand is expected to triplicate by 2050. How this requirement can be satisfied? All the indicators seems to demonstrate that nuclear power will be the solution because of the shortage of other sources, the increase of the prices of the non renewable fuels and the scarce contribution of the renewable ones. In addition, the climatic changes produced by the greenhouse effect make even more attractive nuclear power. The situation of Argentina is analyzed and compared with other countries. The convenience of an increase of nuclear power contribution to the total national generation seems clear and the conclusion of the construction of the Atucha II nuclear power plant is recommended

  14. Implementation of a radiological emergency monitoring system for Bruce Power nuclear power plant (Canada); Implementierung eines radiologischen Umgebungsueberwachungsmesssystems fuer das Kernkraftwerk Bruce Power (Kanada)

    Energy Technology Data Exchange (ETDEWEB)

    Madaric, M. [Saphymo GmbH, Frankfurt (Germany)

    2016-07-01

    The Bruce Power nuclear power plant (BP NPP) in Ontario, Canada, is the largest nuclear generating station in the world, operating 8 nuclear reactors producing 6300 MW. In correlation with Bruce Power's safety culture, ''Safety first'' and continuous improvements are essential and substantial parts of the Bruce Power philosophy and management system. After the Fukushima nuclear accident the existing radiological emergency monitoring was analyzed and improved.

  15. Tiny Integrated Network Analyzer for Noninvasive Measurements of Electrically Small Antennas

    DEFF Research Database (Denmark)

    Buskgaard, Emil Feldborg; Krøyer, Ben; Tatomirescu, Alexandru

    2016-01-01

    the system. The tiny integrated network analyzer is a stand-alone Arduino-based measurement system that utilizes the transmit signal of the system under test as its reference. It features a power meter with triggering ability, on-board memory, universal serial bus, and easy extendibility with general...

  16. Research on Compensating Power Converter used for Artillery

    Directory of Open Access Journals (Sweden)

    Xing Wang

    2014-11-01

    Full Text Available Aiming at the low efficiency shortage of traditional power supply converter used for artillery, a novel compensating power converter used for artillery was proposed, and its work mode was analyzed. The current expression of inductor was given and work statuses under two working modes were analyzed. Finally an experimental prototype based on DSP was built, the results indicate that the compensating power converter own low current and voltage stress and high efficiency because only part of power pass through the converter, thus, the converter own large potential application value.

  17. Critical success factors for BOT electric power projects in China: Thermal power versus wind power

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Zhen-Yu. [School of Business Administration, North China Electric Power University, Beijing 102206 (China); Zuo, Jian; Zillante, George [School of Natural and Built Environments, University of South Australia, Adelaide 5001 (Australia); Wang, Xin-Wei [Shandong Nuclear Power Equipment Manufacturing Co. Ltd, Haiyang, Shandong 265118 (China)

    2010-06-15

    Chinese electric power industry has adopted Build-Operate-Transfer (BOT) approach in a number of projects to alleviate the pressure of sole state-owned investment. The Chinese government has taken enormous efforts to create an environment to facilitate the application of BOT approach in electric power projects. Moreover, the growing attention on the sustainability issues puts the traditional major source of electricity - thermal power project under more strict scrutiny. As a result, various renewable energy projects, particularly the wind power projects have involved private sector funds. Both thermal power and wind power projects via BOT approach have met with a varying degree of success. Therefore, it is imperative to understand the factors contributing towards the success of both types of BOT power projects. Using an extensive literature survey, this paper identifies 31 success factors under 5 categories for Chinese BOT electric power projects. This is followed by a questionnaire survey to exam relative significance of these factors. The results reveal the different levels of significance of success factors for BOT thermal power projects versus wind power projects. Finally, survey results were analyzed to explore the underlying construction and distributions among the identified success factors. This study provides a valuable reference for all involved parties that are interested in developing BOT electric power projects in China. (author)

  18. A data mining approach: Analyzing wind speed and insolation period data in Turkey for installations of wind and solar power plants

    International Nuclear Information System (INIS)

    Colak, Ilhami; Sagiroglu, Seref; Demirtas, Mehmet; Yesilbudak, Mehmet

    2013-01-01

    Highlights: ► Wind speed and insolation period data were analyzed using a data mining approach. ► Most of the studies in the literature were based on Weibull and Rayleigh models. ► Nearest and farest neighbor algorithms were used with different distance metrics. ► Many inferences were achieved in efficient limits for wind and solar farm analyses. - Abstract: Wind and solar power plant installations have been recently increased rapidly with respect to the depletion of fossil-based fuels all over the world. Due to stochastic nature of meteorological conditions, wind and solar energies have a non-schedulable nature and they require several installation analyses to determine the location and the capacities of wind and solar power to be produced. This paper focuses on the similarity, feasibility and numerical analyses of 75 cities in Turkey based on the monthly average wind speed and insolation period data. The nearest and the farest neighbor algorithms are used as agglomerative hierarchical clustering methods with Euclidean, Manhattan and Minkowski distance metrics in the stage of making the similarity and feasibility analyses. The maximum cophenetic correlation coefficient is achieved by the nearest neighbor algorithm with the Minkowski distance metric in the similarity and feasibility analyses. On the other hand, graphical representations of the monthly average wind speed and insolation period data are utilized for making the numerical analysis. The highest annual average wind speed and insolation period are obtained as 3.88 m/s and 8.45 h/day, respectively. Overall, many inferences were achieved in acceptable and efficient limits for wind and solar energy.

  19. On energy efficient power allocation for power-constrained systems

    KAUST Repository

    Sboui, Lokman

    2014-09-01

    Recently, the energy efficiency (EE) has become an important factor when designing new wireless communication systems. Due to economic and environmental challenges, new trends and efforts are oriented toward “green” communication especially for energy-constrained applications such as wireless sensors network and cognitive radio. To this end, we analyze the power allocation scheme that maximizes the EE defined as rate over the total power including circuit power. We derive an explicit expression of the optimal power with instantaneous channel gain based on EE criterion. We show that the relation between the EE and the spectral efficiency (SE) when the optimal power is adopted is strictly increasing in contrast with the SE-EE trade-off discussed in the literature. We also solve a non-convex problem and compute explicitly the optimal power for ergodic EE under either a peak or an average power constraint. When the instantaneous channel is not available, we provide the optimal power equation and compute simple sub-optimal power. In the numerical results, we show that the sup-optimal solution is very close to the optimal solution. In addition, we show that the absence of the channel state information (CSI) only affects the EE and the SE performances at high power regime compared to the full CSI case.

  20. WhalePower tubercle blade power performance test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-15

    Toronto-based WhalePower Corporation has developed turbine blades that are modeled after humpback whale flippers. The blades, which incorporate tubercles along the leading edge of the blade, have been fitted to a Wenvor 25 kW turbine installed in North Cape, Prince Edward Island at a test site for the Wind Energy Institute of Canada (WEICan). A test was conducted to characterize the power performance of the prototype wind turbine. This report described the wind turbine configuration with particular reference to turbine information, power rating, blade information, tower information, control systems and grid connections. The test site was also described along with test equipment and measurement procedures. Information regarding power output as a function of wind speed was included along with power curves, power coefficient and annual energy production. The results for the power curve and annual energy production contain a level of uncertainty. While measurements for this test were collected and analyzed in accordance with International Electrotechnical Commission (IEC) standards for performance measurements of electricity producing wind turbines (IEC 61400-12-1), the comparative performance data between the prototype WhalePower wind turbine blade and the Wenvor standard blade was not gathered to IEC data standards. Deviations from IEC-61400-12-1 procedures were listed. 6 tabs., 16 figs., 3 appendices.

  1. Power and welfare

    DEFF Research Database (Denmark)

    Mik-Meyer, Nanna; Villadsen, Kasper

    readily evident that power is at stake when institutions educate, counsel or ‘empower’ citizens. This book offers a framework for understanding and analyzing these complex and implicit forms of power at play in the encounters between citizens and welfare institutions. Taking as its starting point the idea......In the welfare provision of today, power takes both the shape of juridical sanctions and of attractive offers for self-development. When state institutions punish criminals, remove children at risk, or enforce sanctions upon welfare recipients the question of power is immediately urgent. It is less...... that power takes many different shapes, and that different approaches to power may be necessary in the diverse contexts where citizens encounter welfare professionals, the book demonstrates how significant social theorists, spanning from Goffman to Foucault, can be used for inquiries into these encounters...

  2. Power and Welfare

    DEFF Research Database (Denmark)

    Mik-Meyer, Nanna; Villadsen, Kaspar

    readily evident that power is at stake when institutions educate, counsel or 'empower' citizens. This book offers a framework for understanding and analyzing these complex and implicit forms of power at play in the encounters between citizens and welfare institutions. Taking as its starting point the idea......In the welfare provision of today, power takes both the shape of juridical sanctions and of attractive offers for self-development. When state institutions punish criminals, remove children at risk, or enforce sanctions upon welfare recipients the question of power is immediately urgent. It is less...... that power takes many different shapes, and that different approaches to power may be necessary in the diverse contexts where citizens encounter welfare professionals, the book demonstrates how significant social theorists, spanning from Goffman to Foucault, can be used for inquiries into these encounters...

  3. Measurement of the tensor Ayy and vector Ay analyzing powers of the deuteron inelastic scattering on beryllium at 5.0 GeV/c and 178 mrad

    International Nuclear Information System (INIS)

    Azhgirej, L.S.; Afanas'ev, S.V.; Isupov, A.Yu.

    2004-01-01

    Tensor A yy and vector A y analyzing powers in the inelastic scattering of deuterons with a momentum of 5.0 GeV/c on beryllium at an angle of 178 mrad in the vicinity of the excitation of baryonic resonances with masses up to ∼ 1.8 GeV/c 2 have been measured. The A yy data are in good agreement with the previous data obtained at 4.5 and 5.5 GeV/c. The results of the experiment are compared with the predictions of the plane-wave impulse approximation and ω-meson exchange model

  4. Power system security enhancement with unified power flow controller under multi-event contingency conditions

    Directory of Open Access Journals (Sweden)

    S. Ravindra

    2017-03-01

    Full Text Available Power system security analysis plays key role in enhancing the system security and to avoid the system collapse condition. In this paper, a novel severity function is formulated using transmission line loadings and bus voltage magnitude deviations. The proposed severity function and generation fuel cost objectives are analyzed under transmission line(s and/or generator(s contingency conditions. The system security under contingency conditions is analyzed using optimal power flow problem. An improved teaching learning based optimization (ITLBO algorithm has been presented. To enhance the system security under contingency conditions in the presence of unified power flow controller (UPFC, it is necessary to identify an optimal location to install this device. Voltage source based power injection model of UPFC, incorporation procedure and optimal location identification strategy based on line overload sensitivity indexes are proposed. The entire proposed methodology is tested on standard IEEE-30 bus test system with supporting numerical and graphical results.

  5. Wind Energy System Time-domain (WEST) analyzers using hybrid simulation techniques

    Science.gov (United States)

    Hoffman, J. A.

    1979-01-01

    Two stand-alone analyzers constructed for real time simulation of the complex dynamic characteristics of horizontal-axis wind energy systems are described. Mathematical models for an aeroelastic rotor, including nonlinear aerodynamic and elastic loads, are implemented with high speed digital and analog circuitry. Models for elastic supports, a power train, a control system, and a rotor gimbal system are also included. Limited correlation efforts show good comparisons between results produced by the analyzers and results produced by a large digital simulation. The digital simulation results correlate well with test data.

  6. Adequacy of operating reserves for power systems in future european wind power scenarios

    DEFF Research Database (Denmark)

    Das, Kaushik; Litong-Palima, Marisciel; Maule, Petr

    2015-01-01

    operating reserves. To study the effects of these imbalances, anticipated wind scenarios for European power systems are modelled for 2020 and 2030. Wind power forecasts for different time scales and real-time available wind power are modelled. Based on these studies, this paper qualitatively analyzes......Wind power generation is expected to increase in Europe by large extent in future. This will increase variability and uncertainty in power systems. Imbalances caused due to uncertainty in wind power forecast can trigger frequency instability in the system. These imbalances are handled using...... the adequacy of primary and secondary reserves requirements for future European power systems. This paper also discusses the challenges due to the uncertainty in wind power forecasts and their possible solutions for wind installation scenarios for 2020 and 2030....

  7. Power Curve Measurements, FGW

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine....

  8. Power Curve Measurements FGW

    DEFF Research Database (Denmark)

    Federici, Paolo; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine...

  9. Supplementary speed control for wind power smoothing

    NARCIS (Netherlands)

    Haan, de J.E.S.; Frunt, J.; Kechroud, A.; Kling, W.L.

    2010-01-01

    Wind fluctuations result in even larger wind power fluctuations because the power of wind is proportional to the cube of the wind speed. This report analyzes wind power fluctuations to investigate inertial power smoothing, in particular for the frequency range of 0.08 - 0.5 Hz. Due to the growing

  10. Perspectives of nuclear power plants

    International Nuclear Information System (INIS)

    Vajda, Gy.

    2001-01-01

    In several countries the construction of nuclear power plants has been stopped, and in some counties several plants have been decommissioned or are planned to. Therefore, the question arises: have nuclear power plants any future? According to the author, the question should be reformulated: can mankind survive without nuclear power? To examine this challenge, the global power demand and its trends are analyzed. According to the results, traditional energy sources cannot be adequate to supply power. Therefore, a reconsideration of nuclear power should be imminent. The economic, environmental attractions are discussed as opposite to the lack of social support. (R.P.)

  11. Ergonomics as aid tool to identify and to analyze factors that can affect the operational performance of nuclear power plants

    International Nuclear Information System (INIS)

    Luquetti Santos, I.J.A.; Carvalho, P.V.R.

    2005-01-01

    The study of ergonomics has evolved around the world as one of the keys to understand human behavior in interaction with complex systems as nuclear power plant and to achieve the best match between the system and its users in the context of task to be performed. Increasing research efforts have yielded a considerable body of knowledge concerning the design of workstations, workplace, control rooms, human-system interfaces, user-interface interaction and organizational design to prevent worker discomfort, illness and also to improve productivity, product quality, ease of use and safety. The work ergonomics analysis consists of gathering a series of observation in order to better understand the work done and to propose changes and improvements in the working conditions. The work ergonomics analysis implies both the correction of existing situations (safety, reliability and production problems) and the development of new work system. Operator activity analysis provides a useful tool for the ergonomics approach, based on work ergonomics analysis. The operators will be systematically observed in their real work environment (control room) or in simulators. The focus is on description of the distributed regulated mechanisms (in the sense that operators work in crew), both in nominal and degraded situations, observing how operators regulate collectively their work during an increase in workload or when confronted with situations where incidents or accidents occur. Audio, video recorders and field notes can be used to collect empirical data, conversations and interactions that occur naturally within the work environment. Our research develops an applied ergonomics methodology, based on field studies, that permits to identify and analyze situations, factors that may affect the operational performance of nuclear power plants. Our contribution is related to the following technical topic: How best to learn from and share operational safety experience and manage changes during

  12. Nuclear power safety economics

    International Nuclear Information System (INIS)

    Legasov, V.A.; Demin, V.F.; Shevelev, Ya.V.

    1984-01-01

    The existing conceptual and methodical basis for the decision-making process insuring safety of the nuclear power and other (industrial and non-industrial) human activities is critically analyzed. Necessity of development a generalized economic safety analysis method (GESAM) is shown. Its purpose is justifying safety measures. Problems of GESAM development are considered including the problem of costing human risk. A number of suggestions on solving them are given. Using the discounting procedure in the assessment of risk or detriment caused by harmful impact on human health is substantiated. Examples of analyzing some safety systems in the nuclear power and other spheres of human activity are given

  13. Day ahead forecast of wind power through optimal application of multivariate analyzing methods

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldt, Alexander; Bretschneider, Peter [Fraunhofer Institute for Optronics, System Technology, and Image Exploitation - Application Centre System Technology (IOSB-AST), Ilmenau (Germany). Energy Systems Group

    2011-07-01

    This paper presents two algorithms in identifying input models for artificial neural networks. The algorithms are based on an entropy analysis and an eigenvalue analysis of the correlation matrix. The resulting input models are used for investigating a feed forward and a recurrent artificial neural network structure to simulate a 24 hour forecast of wind power production. The limitation of the forecast error distribution is investigated through successful implementation of hybridization of single forecast models. Errors of the best forecast model stay between a normalized root mean square error from 3.5% to 6.1%. (orig.)

  14. Power and Conflict in Adaptive Management: Analyzing the Discourse of Riparian Management on Public Lands

    Directory of Open Access Journals (Sweden)

    Jennifer S. Arnold

    2012-03-01

    Full Text Available Adaptive collaborative management emphasizes stakeholder engagement as a crucial component of resilient social-ecological systems. Collaboration among diverse stakeholders is expected to enhance learning, build social legitimacy for decision making, and establish relationships that support learning and adaptation in the long term. However, simply bringing together diverse stakeholders does not guarantee productive engagement. Using critical discourse analysis, we examined how diverse stakeholders negotiated knowledge and power in a workshop designed to inform adaptive management of riparian livestock grazing on a National Forest in the southwestern USA. Publicly recognized as a successful component of a larger collaborative effort, we found that the workshop effectively brought together diverse participants, yet still restricted dialogue in important ways. Notably, workshop facilitators took on the additional roles of riparian experts and instructors. As they guided workshop participants toward a consensus view of riparian conditions and management recommendations, they used their status as riparian experts to emphasize commonalities with stakeholders supportive of riparian grazing and accentuate differences with stakeholders skeptical of riparian grazing, including some Forest Service staff with power to influence management decisions. Ultimately, the management plan published one year later did not fully adopt the consensus view from the workshop, but rather included and acknowledged a broader diversity of stakeholder perspectives. Our findings suggest that leaders and facilitators of adaptive collaborative management can more effectively manage for productive stakeholder engagement and, thus, social-ecological resilience if they are more tentative in their convictions, more critical of the role of expert knowledge, and more attentive to the knowledge, interests, and power of diverse stakeholders.

  15. Validation of the Engineering Plant Analyzer methodology with Peach Bottom 2 stability tests

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Mallen, A.N.; Cheng, H.S.; Wulff, W.

    1994-01-01

    The Engineering Plant Analyzer (EPA) had been developed in 1984 at Brookhaven National Laboratory to simulate plant transients in boiling water reactors (BWR). Recently, the EPA with its High-Speed Interactive Plant Analyzer code for BWRs ( ppercase HIPA-BWR ) simulated for the first time oscillatory transients with large, non-linear power and flow amplitudes; transients which are centered around the March 9, 1988 instability at the LaSalle-2 BWR power plant.The EPA's capability to simulate oscillatory transients has been demonstrated first by comparing simulation results with LaSalle-2 plant data (Wulff et al., NUREG/CR-5816, BNL-NUREG-52312, Brookhaven National Laboratory, 1992). This paper presents an EPA assessment on the basis of the Peach Bottom 2 instability tests (Carmichael and Niemi, EPRI NP-564, Electric Power Research Institute, Palo Alto, CA, 1978). This assessment of the EPA appears to constitute the first validation of a time-domain reactor systems code on the basis of frequency-domain criteria, namely power spectral density, gain and phase shift of the pressure-to-power transfer function.The reactor system pressure was disturbed in the Peach Bottom 2 power plant tests, and in their EPA simulation, by a pseudo-random, binary sequence signal. The data comparison revealed that the EPA predicted for Peach Bottom tests PT1, PT2, and PT4 the gain of the power-to-pressure transfer function with the biases and standard deviations of (-10±28)%, (-1±40)% and (+28±52)%, respectively. The respective frequencies at the peak gains were predicted with the errors of +6%, +3%, and -28%. The differences between the predicted and the measured phase shift increased with increasing frequency, but stayed within the margin of experimental uncertainty. ((orig.))

  16. Research on unit commitment with large-scale wind power connected power system

    Science.gov (United States)

    Jiao, Ran; Zhang, Baoqun; Chi, Zhongjun; Gong, Cheng; Ma, Longfei; Yang, Bing

    2017-01-01

    Large-scale integration of wind power generators into power grid brings severe challenges to power system economic dispatch due to its stochastic volatility. Unit commitment including wind farm is analyzed from the two parts of modeling and solving methods. The structures and characteristics can be summarized after classification has been done according to different objective function and constraints. Finally, the issues to be solved and possible directions of research and development in the future are discussed, which can adapt to the requirements of the electricity market, energy-saving power generation dispatching and smart grid, even providing reference for research and practice of researchers and workers in this field.

  17. Analyzing the development of Indonesia shrimp industry

    Science.gov (United States)

    Wati, L. A.

    2018-04-01

    This research aimed to analyze the development of shrimp industry in Indonesia. Porter’s Diamond Theory was used for analysis. The Porter’s Diamond theory is one of framework for industry analysis and business strategy development. The Porter’s Diamond theory has five forces that determine the competitive intensity in an industry, namely (1) the threat of substitute products, (2) the threat of competition, (3) the threat of new entrants, (4) bargaining power of suppliers, and (5) bargaining power of consumers. The development of Indonesian shrimp industry pretty good, explained by Porter Diamond Theory analysis. Analysis of Porter Diamond Theory through four main components namely factor conditions; demand condition; related and supporting industries; and firm strategy, structure and rivalry coupled with a two-component supporting (regulatory the government and the factor of chance). Based on the result of this research show that two-component supporting (regulatory the government and the factor of chance) have positive. Related and supporting industries have negative, firm and structure strategy have negative, rivalry has positive, factor condition have positive (except science and technology resources).

  18. Evaluation of Approaches to Analyzing Continuous Correlated Eye Data When Sample Size Is Small.

    Science.gov (United States)

    Huang, Jing; Huang, Jiayan; Chen, Yong; Ying, Gui-Shuang

    2018-02-01

    To evaluate the performance of commonly used statistical methods for analyzing continuous correlated eye data when sample size is small. We simulated correlated continuous data from two designs: (1) two eyes of a subject in two comparison groups; (2) two eyes of a subject in the same comparison group, under various sample size (5-50), inter-eye correlation (0-0.75) and effect size (0-0.8). Simulated data were analyzed using paired t-test, two sample t-test, Wald test and score test using the generalized estimating equations (GEE) and F-test using linear mixed effects model (LMM). We compared type I error rates and statistical powers, and demonstrated analysis approaches through analyzing two real datasets. In design 1, paired t-test and LMM perform better than GEE, with nominal type 1 error rate and higher statistical power. In design 2, no test performs uniformly well: two sample t-test (average of two eyes or a random eye) achieves better control of type I error but yields lower statistical power. In both designs, the GEE Wald test inflates type I error rate and GEE score test has lower power. When sample size is small, some commonly used statistical methods do not perform well. Paired t-test and LMM perform best when two eyes of a subject are in two different comparison groups, and t-test using the average of two eyes performs best when the two eyes are in the same comparison group. When selecting the appropriate analysis approach the study design should be considered.

  19. Integrated Control for Small Power Wind Generator

    Directory of Open Access Journals (Sweden)

    Hongliang Liu

    2018-05-01

    Full Text Available The control strategies of the small power wind generator are usually divided into the maximum power point tracking (MPPT case, which requires the wind generator produce power as much as possible, and the power limited control (PLC case that demands the wind generator produce a power level following the load requirement. Integration of these two operating cases responding to flexible and sophisticated power demands is the main topic of this article. A small power wind generator including the sluggish mechanical dynamic phenomenon, which uses the permanent magnet synchronous generator, is introduced to validate different control methods integrating MPPT and PLC cases and based on hysteresis control. It is a matter of an indirect power control method derived from three direct methods following perturb and observe principle as well as from a look-up table. To analyze and compare the proposed power control methods, which are implemented into an emulator of a small power wind generator, a power demand profile is used. This profile is randomly generated based on measured rapid wind velocity data. Analyzing experimental results, from the power viewpoint, all proposed methods reveal steady-state error with big amount of peak resulting from the nature of perturb and observe.

  20. Capturing and analyzing wheelchair maneuvering patterns with mobile cloud computing.

    Science.gov (United States)

    Fu, Jicheng; Hao, Wei; White, Travis; Yan, Yuqing; Jones, Maria; Jan, Yih-Kuen

    2013-01-01

    Power wheelchairs have been widely used to provide independent mobility to people with disabilities. Despite great advancements in power wheelchair technology, research shows that wheelchair related accidents occur frequently. To ensure safe maneuverability, capturing wheelchair maneuvering patterns is fundamental to enable other research, such as safe robotic assistance for wheelchair users. In this study, we propose to record, store, and analyze wheelchair maneuvering data by means of mobile cloud computing. Specifically, the accelerometer and gyroscope sensors in smart phones are used to record wheelchair maneuvering data in real-time. Then, the recorded data are periodically transmitted to the cloud for storage and analysis. The analyzed results are then made available to various types of users, such as mobile phone users, traditional desktop users, etc. The combination of mobile computing and cloud computing leverages the advantages of both techniques and extends the smart phone's capabilities of computing and data storage via the Internet. We performed a case study to implement the mobile cloud computing framework using Android smart phones and Google App Engine, a popular cloud computing platform. Experimental results demonstrated the feasibility of the proposed mobile cloud computing framework.

  1. Neutral Beam Power System for TPX

    International Nuclear Information System (INIS)

    Ramakrishnan, S.; Bowen, O.N.; O'Conner, T.; Edwards, J.; Fromm, N.; Hatcher, R.; Newman, R.; Rossi, G.; Stevenson, T.; von Halle, A.

    1993-01-01

    The Tokamak Physics Experiment (TPX) will utilize to the maximum extent the existing Tokamak Fusion Test Reactor (TFTR) equipment and facilities. This is particularly true for the TFTR Neutral Beam (NB) system. Most of the NB hardware, plant facilities, auxiliary sub-systems, power systems, service infrastructure, and control systems can be used as is. The major changes in the NB hardware are driven by the new operating duty cycle. The TFTR Neutral Beam was designed for operation of the Sources for 2 seconds every 150 seconds. The TPX requires operation for 1000 seconds every 4500 seconds. During the Conceptual Design Phase of TPX every component of the TFTR NB Electrical Power System was analyzed to verify whether the equipment can meet the new operational requirements with our without modifications. The Power System converts 13.8 kV prime power to controlled pulsed power required at the NB sources. The major equipment involved are circuit breakers, auto and rectifier transformers surge suppression components, power tetrodes, HV Decks, and HVDC power transmission to sources. Thermal models were developed for the power transformers to simulate the new operational requirements. Heat runs were conducted for the power tetrodes to verify capability. Other components were analyzed to verify their thermal limitations. This paper describes the details of the evaluation and redesign of the electrical power system components to meet the TPX operational requirements

  2. Analyzing negative ties in social networks

    Directory of Open Access Journals (Sweden)

    Mankirat Kaur

    2016-03-01

    Full Text Available Online social networks are a source of sharing information and maintaining personal contacts with other people through social interactions and thus forming virtual communities online. Social networks are crowded with positive and negative relations. Positive relations are formed by support, endorsement and friendship and thus, create a network of well-connected users whereas negative relations are a result of opposition, distrust and avoidance creating disconnected networks. Due to increase in illegal activities such as masquerading, conspiring and creating fake profiles on online social networks, exploring and analyzing these negative activities becomes the need of hour. Usually negative ties are treated in same way as positive ties in many theories such as balance theory and blockmodeling analysis. But the standard concepts of social network analysis do not yield same results in respect of each tie. This paper presents a survey on analyzing negative ties in social networks through various types of network analysis techniques that are used for examining ties such as status, centrality and power measures. Due to the difference in characteristics of flow in positive and negative tie networks some of these measures are not applicable on negative ties. This paper also discusses new methods that have been developed specifically for analyzing negative ties such as negative degree, and h∗ measure along with the measures based on mixture of positive and negative ties. The different types of social network analysis approaches have been reviewed and compared to determine the best approach that can appropriately identify the negative ties in online networks. It has been analyzed that only few measures such as Degree and PN centrality are applicable for identifying outsiders in network. For applicability in online networks, the performance of PN measure needs to be verified and further, new measures should be developed based upon negative clique concept.

  3. Design of The High Efficiency Power Factor Correction Circuit for Power Supply

    Directory of Open Access Journals (Sweden)

    Atiye Hülya OBDAN

    2017-12-01

    Full Text Available Designing power factor correction circuits for switched power supplies has become important in recent years in terms of efficient use of energy. Power factor correction techniques play a significant role in high power density and energy efficiency. For these purposes, bridgeless PFC topologies and control strategies have been developed alongside basic boost PFC circuits. The power density can be increased using bridgeless structures by means of reducing losses in the circuit. This article examines bridgeless PFC structures and compares their performances in terms of losses and power factor. A semi-bridgeless PFC, which is widely used at high power levels, was analyzed and simulated. The designed circuit simulation using the current mode control method was performed in the PSIM program. A prototype of a 900 W semi-bridgeless PFC circuit was implemented and the results obtained from the circuit are presented

  4. Meeting summary of the second CSNI specialist meeting on simulators and plant analyzers - Current Issues in Nuclear Power Plant Simulation

    International Nuclear Information System (INIS)

    1998-01-01

    The Second CSNI Specialist Meeting on Simulators and Plant Analyzers: Current Issues in Nuclear Power Plant Simulation was held in Espoo, Finland, from September 29 through October 2, 1997. It was organised by CSNI Principal Working Group on Coolant System Behaviour (PWG2), Task Group on Thermal Hydraulic Applications (TG-THA), in co-operation with Technical Research Centre of Finland. The meeting in Espoo attracted some 90 participants from 17 countries. A total of 49 invited papers were presented in the meeting in addition to 7 simulator system demonstrations. Ample time was reserved for the presentations and informal discussions during the four meeting days. The previous meeting held in Lappeenranta, Finland, in 1992 collected some 85 participants from 12 countries, presenting a total of 40 papers. The meeting was structured into 6 sessions covering the important aspects of development and use of simulators and plant analyzers: Session I: New objectives, Requirements and Concepts. This session covered the progress experienced since the 1. simulator meeting and tried to address the changing role of simulators based on the changes in users' needs and developing possibilities. Session II: Trends in Simulation Technology. This session was reserved for studying the current trends in the simulation technology: software environments, visualisation, simulator configuration tools, programming languages and computer systems. Session III: Training and human factor studies using simulators. This session was created for studying the status of different uses of simulators such as educational simulators, human factor studies and integrated safety assessment in addition to traditional training. Regarding to the severe accidents, a question was raised whether the simulator use should be for training or education. Session IV: Modelling techniques. The session on modelling techniques was included to cover recent developments in the modelling techniques applicable to training

  5. Chaos in power: Pakistan's electricity crisis

    International Nuclear Information System (INIS)

    Kessides, Ioannis N.

    2013-01-01

    Pakistan is facing a severe electricity crisis due to a persistent and widening gap between demand and available system generating capacity. The worsening of power shortages has become a major political issue, reflecting the hardships for individuals and businesses. It threatens to undermine the credibility and legitimacy of government and to further stress the social fabric of the country. The power crisis did not emerge suddenly. It is the direct result of imprudent and reckless energy policies over the last three decades. These policies have impeded the development of cheap and abundant domestic energy sources. They have also resulted in very inefficient fuel-mix choices, compromising energy and economic security. Pakistan's energy bankruptcy is ultimately due to massive institutional and governance failure. This paper analyzes the problems confronting Pakistan's electricity sector and identifies the key elements of a potential policy response to address the country's severe power crisis. - Highlights: ► We analyze the structure, conduct, and performance of Pakistan's electricity sector. ► The causes and economic impacts of Pakistan's electricity shortages are analyzed. ► We identify the potential policy response to the power crisis

  6. Interactive graphical analyzer based on RELAP5/MOD3.2-NPA

    International Nuclear Information System (INIS)

    Posada, J.M.; Martin, M.; Reventos, F.; Llopis, C.

    1999-01-01

    The work presented in this paper consists on the development of a Graphical Interactive Analyzer for Asco (two units) and Vandellos (one unit) Nuclear Power Plants, all of them are three loop Westinghouse PWR with rated electrical power around 1000 Mwe. Basic steps are: Development of the thermal-hydraulic and kinetic model for RELAP5/mod3.2 corresponding to NSSS, Steam Flow paths from Steam Generators to Turbine and Condenser, Feedwater System, Emergency Core Cooling System; and related protection and control systems. Development of Graphical representation, for NPA-1.3.4., to permit the user interact with the model. Validation against experimental data. The result is an engineering tool that can help on Plant transient analysis, and on the study of modifications proposed on the components simulated; it's also a powerful tool for operator teaching. (author)

  7. EXPERIMENTAL STUDY AND PERFORMANCE OF SOLAR ENERGY SYSTEM WITH GRID CONNECTED POWER SUPPLY

    OpenAIRE

    Pradeep Bharti; Dr. A.K.Sharma

    2017-01-01

    In this paper , we are analyzed about the solar power with grid connection using of various component such as PV Cells battery inverter, and grid power connection , in this way we are connected the grid power and solar power , after that finally we are analyzed the power quality of output with the help of various devices.

  8. Performance of Identifiler Direct and PowerPlex 16 HS on the Applied Biosystems 3730 DNA Analyzer for processing biological samples archived on FTA cards.

    Science.gov (United States)

    Laurin, Nancy; DeMoors, Anick; Frégeau, Chantal

    2012-09-01

    Direct amplification of STR loci from biological samples collected on FTA cards without prior DNA purification was evaluated using Identifiler Direct and PowerPlex 16 HS in conjunction with the use of a high throughput Applied Biosystems 3730 DNA Analyzer. In order to reduce the overall sample processing cost, reduced PCR volumes combined with various FTA disk sizes were tested. Optimized STR profiles were obtained using a 0.53 mm disk size in 10 μL PCR volume for both STR systems. These protocols proved effective in generating high quality profiles on the 3730 DNA Analyzer from both blood and buccal FTA samples. Reproducibility, concordance, robustness, sample stability and profile quality were assessed using a collection of blood and buccal samples on FTA cards from volunteer donors as well as from convicted offenders. The new developed protocols offer enhanced throughput capability and cost effectiveness without compromising the robustness and quality of the STR profiles obtained. These results support the use of these protocols for processing convicted offender samples submitted to the National DNA Data Bank of Canada. Similar protocols could be applied to the processing of casework reference samples or in paternity or family relationship testing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Analyzing the decision making process of certifying digital control systems of nuclear power plants

    International Nuclear Information System (INIS)

    Yih, Swu; Fan, Chin-Feng

    2012-01-01

    Highlights: ► We have performed basic research in analyzing certification process and developed a regulatory decision making model for nuclear digital control system certification. The model views certification as an evidence–confidence conversion process. ► We have applied this model to analyze previous nuclear digital I and C certification experiences and obtained valuable insights. ► Furthermore, a prototype of a computer-aided licensing support system based on the model has been developed to enhance regulatory review efficiency. - Abstract: Safety-critical computing systems need regulators’ approval before operation. Such a permit issue process is called “certification”. Digital instrumentation and Control (I and C) certification in the nuclear domain has always been problematic and lengthy. Thus, the certification efficiency has always been a crucial concern to the applicant whose business depends on the regulatory decision. However, to our knowledge, there is little basic research on this topic. This study presents a Regulatory Decision-Making Model aiming at analyzing the characteristics and efficiency influence factors in a generic certification process. This model is developed from a dynamic operational perspective by viewing the certification process as an evidence–confidence conversion process. The proposed model is then applied to previous nuclear digital I and C certification experiences to successfully explain why some cases were successful and some were troublesome. Lessons learned from these cases provide invaluable insights regarding to the regulatory review activity. Furthermore, to utilize the insights obtained from the model, a prototype of a computer-aided licensing support system has been developed to speed up review evidence preparation and manipulation; thus, regulatory review efficiency can be further improved.

  10. Investigation And Mitigation Techniques Of Power Quality Problems In Nuclear Installations

    International Nuclear Information System (INIS)

    Ayad, N.; Elsherbiny, E.; Eleissawi, H.; Zaher, M.; AbdelSalam, G.

    2013-01-01

    The electrical power systems are exposed to different types of power quality disturbances problems. Investigation and monitoring of power quality is necessary to maintain accurate operation of sensitive equipment especially for nuclear installations. The present research discusses investigation and monitoring of power quality problems for the electrical sources of nuclear installations. Field power quality data is collected by power analyzer and analyzed with reference to power quality standards. There were several disturbances exceeded the thresholds, they were voltage harmonics and voltage flicker. Mitigation techniques were suggested to install a passive filter at low voltage side and all sensitive and critical loads should be isolated and fed through uninterruptible power supply (UPS)

  11. Optimal Operation of Plug-In Electric Vehicles in Power Systems with High Wind Power Penetrations

    DEFF Research Database (Denmark)

    Hu, Weihao; Su, Chi; Chen, Zhe

    2013-01-01

    in the power systems with high wind power penetrations. In this paper, the integration of plug-in electric vehicles in the power systems with high wind power penetrations is proposed and discussed. Optimal operation strategies of PEV in the spot market are proposed in order to decrease the energy cost for PEV......The Danish power system has a large penetration of wind power. The wind fluctuation causes a high variation in the power generation, which must be balanced by other sources. The battery storage based Plug-In Electric Vehicles (PEV) may be a possible solution to balance the wind power variations...... owners. Furthermore, the application of battery storage based aggregated PEV is analyzed as a regulation services provider in the power system with high wind power penetrations. The western Danish power system where the total share of annual wind power production is more than 27% of the electrical energy...

  12. Nuclear power ecology: comparative analysis

    International Nuclear Information System (INIS)

    Trofimenko, A.P.; Lips'ka, A.Yi.; Pisanko, Zh.Yi.

    2005-01-01

    Ecological effects of different energy sources are compared. Main actions for further nuclear power development - safety increase and waste management, are noted. Reasons of restrained public position to nuclear power and role of social and political factors in it are analyzed. An attempt is undertaken to separate real difficulties of nuclear power from imaginary ones that appear in some mass media. International actions of environment protection are noted. Risk factors at different energy source using are compared. The results of analysis indicate that ecological influence and risk for nuclear power are of minimum

  13. Power reserve provision with wind farms. Grid integration of wind power

    Energy Technology Data Exchange (ETDEWEB)

    Gesino, Alejandro J.

    2011-07-01

    Wind power is, admittedly, different from other power technologies and integrating large amounts of it in the existing power systems is a challenge that requires innovative approaches to keep the sustainability of the power system operation. In the coming years its contribution to the system security will become mandatory as far as the trend goes towards more decentralized structures and an increase in complexity due to a higher number of market participants. This PhD addresses one of the fundamental ancillary services researching about a secure and flexible methodology for power reserve provision with wind farms. Based on the current needs and security standards of those highly developed European grid codes, a new model for power reserve provision with wind power is developed. This methodology, algorithms and variables are tested based on real scenarios from five German wind farm clusters. Finally, once the methodology for power reserve provision with wind power has been tested, real control capabilities from already installed wind farms in Germany and Portugal are analyzed. Their capabilities of following control commands as well as an error deviation analysis are also presented. (orig.)

  14. Modeling and Vulnerability Analysis of Cyber-Physical Power Systems Considering Network Topology and Power Flow Properties

    Directory of Open Access Journals (Sweden)

    Jia Guo

    2017-01-01

    Full Text Available Conventional power systems are developing into cyber-physical power systems (CPPS with wide applications of communication, computer and control technologies. However, multiple practical cases show that the failure of cyber layers is a major factor leading to blackouts. Therefore, it is necessary to discuss the cascading failure process considering cyber layer failures and analyze the vulnerability of CPPS. In this paper, a CPPS model, which consists of cyber layer, physical layer and cyber-physical interface, is presented using complex network theory. Considering power flow properties, the impacts of cyber node failures on the cascading failure propagation process are studied. Moreover, two vulnerability indices are established from the perspective of both network structure and power flow properties. A vulnerability analysis method is proposed, and the CPPS performance before and after cascading failures is analyzed by the proposed method to calculate vulnerability indices. In the case study, three typical scenarios are analyzed to illustrate the method, and vulnerabilities under different interface strategies and attack strategies are compared. Two thresholds are proposed to value the CPPS vulnerability roughly. The results show that CPPS is more vulnerable under malicious attacks and cyber nodes with high indices are vulnerable points which should be reinforced.

  15. Striving for Power: Hemingway's Neurosis.

    Science.gov (United States)

    Tavernier-Courbin, Jacqueline

    1978-01-01

    Analyzes the psychological aspects of Ernest Hemingway's inability to accept old age as symptomatic of his neurotic quest for power, which is seen in his drive to excel in pursuits which he thought important, and to take his life when he realized that he was past the peak of his powers. (MB)

  16. Enabling Wind Power Nationwide

    Energy Technology Data Exchange (ETDEWEB)

    Jose Zayas, Michael Derby, Patrick Gilman and Shreyas Ananthan,

    2015-05-01

    Leveraging this experience, the U.S. Department of Energy’s (DOE’s) Wind and Water Power Technologies Office has evaluated the potential for wind power to generate electricity in all 50 states. This report analyzes and quantifies the geographic expansion that could be enabled by accessing higher above ground heights for wind turbines and considers the means by which this new potential could be responsibly developed.

  17. PDA: Pooled DNA analyzer

    Directory of Open Access Journals (Sweden)

    Lin Chin-Yu

    2006-04-01

    Full Text Available Abstract Background Association mapping using abundant single nucleotide polymorphisms is a powerful tool for identifying disease susceptibility genes for complex traits and exploring possible genetic diversity. Genotyping large numbers of SNPs individually is performed routinely but is cost prohibitive for large-scale genetic studies. DNA pooling is a reliable and cost-saving alternative genotyping method. However, no software has been developed for complete pooled-DNA analyses, including data standardization, allele frequency estimation, and single/multipoint DNA pooling association tests. This motivated the development of the software, 'PDA' (Pooled DNA Analyzer, to analyze pooled DNA data. Results We develop the software, PDA, for the analysis of pooled-DNA data. PDA is originally implemented with the MATLAB® language, but it can also be executed on a Windows system without installing the MATLAB®. PDA provides estimates of the coefficient of preferential amplification and allele frequency. PDA considers an extended single-point association test, which can compare allele frequencies between two DNA pools constructed under different experimental conditions. Moreover, PDA also provides novel chromosome-wide multipoint association tests based on p-value combinations and a sliding-window concept. This new multipoint testing procedure overcomes a computational bottleneck of conventional haplotype-oriented multipoint methods in DNA pooling analyses and can handle data sets having a large pool size and/or large numbers of polymorphic markers. All of the PDA functions are illustrated in the four bona fide examples. Conclusion PDA is simple to operate and does not require that users have a strong statistical background. The software is available at http://www.ibms.sinica.edu.tw/%7Ecsjfann/first%20flow/pda.htm.

  18. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  19. Axial power deviation control strategy and computer simulation for Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Liao Yehong; Zhou Xiaoling, Xiao Min

    2004-01-01

    Daya Bay Nuclear Power Station has very tight operation diagram especially at its right side. Therefore the successful control of axial power deviation for PWR is crucial to nuclear safety. After analyzing various core characters' effect on axial power distribution, several axial power deviation control strategies has been proposed to comply with different power varying operation scenario. Application and computer simulation of the strategies has shown that our prediction of axial power deviation evolution are comparable to the measurement values, and that our control strategies are effective. Engineering experience shows that the application of our methodology can predict accurately the transient of axial power deviation, and therefore has become a useful tool for reactor operation and safety control. This paper presents the axial power control characteristics, reactor operation strategy research, computer simulation, and comparison to measurement results in Daya Bay Nuclear Power Station. (author)

  20. Voltage resonant inverter as a power source

    OpenAIRE

    Lupenko, Anatoliy; Stakhiv, Petro

    2014-01-01

    The operation mode of a voltage resonant inverter as a power source with variable load is analyzed. In order to reduce load power variations, an approach to development of the inverter’s load power response based on providing similar positive and negative power deviations from its nominal value has been proposed. The design procedure for resonant inverter with open loop structure as a power source has been elaborated. For a high pressure sodium lamp as a load, the power deviation of about 4% ...

  1. Human reliability analysis of Lingao Nuclear Power Station

    International Nuclear Information System (INIS)

    Zhang Li; Huang Shudong; Yang Hong; He Aiwu; Huang Xiangrui; Zheng Tao; Su Shengbing; Xi Haiying

    2001-01-01

    The necessity of human reliability analysis (HRA) of Lingao Nuclear Power Station are analyzed, and the method and operation procedures of HRA is briefed. One of the human factors events (HFE) is analyzed in detail and some questions of HRA are discussed. The authors present the analytical results of 61 HFEs, and make a brief introduction of HRA contribution to Lingao Nuclear Power Station

  2. Automatic analyzing device for chlorine ion

    International Nuclear Information System (INIS)

    Sugibayashi, Shinji; Morikawa, Yoshitake; Fukase, Kazuo; Kashima, Hiromasa.

    1997-01-01

    The present invention provides a device of automatically analyzing a trance amount of chlorine ions contained in feedwater, condensate and reactor water of a BWR type power plant. Namely, zero-adjustment or span calibration in this device is conducted as follows. (1) A standard chlorine ion liquid is supplied from a tank to a mixer by a constant volume pump, and the liquid is diluted and mixed with purified water to form a standard liquid. (2) The pH of the standard liquid is adjusted by a pH adjuster. (3) The standard liquid is supplied to an electrode cell to conduct zero adjustment or span calibration. Chlorine ions in a specimen are measured by the device of the present invention as follows. (1) The specimen is supplied to a head tank through a line filter. (2) The pH of the specimen is adjusted by a pH adjuster. (3) The specimen is supplied to an electrode cell to electrically measure the concentration of the chlorine ions in the specimen. The device of the present invention can automatically analyze trance amount of chlorine ions at a high accuracy, thereby capable of improving the sensitivity, reducing an operator's burden and radiation exposure. (I.S.)

  3. Greenhouse gas emission factor for coal power chain in China and the comparison with nuclear power chain

    International Nuclear Information System (INIS)

    Ma Zhonghai; Pan Ziqiang; He Huimin

    1999-01-01

    The Greenhouse Gas Emission for coal power chain in China is analyzed in detail and comprehensively by using the Life Cycle Analysis method. The Greenhouse Gas Emission Factors (GGEF) in each link and for the total power chain are calculated. The total GGEF for coal power chain is 1302.3 gCO 2 /kWh, about 40 times more than that for nuclear power chain. And consequently greenhouse effect could not be aggravated further by nuclear power. The energy strategy for nuclear power development is one of reality ways to retard the greenhouse effect, put resources into rational use and protect environment

  4. The design of portable X-ray fluorescence analyzer based on PDA

    International Nuclear Information System (INIS)

    Zhou Jianbin; Ma Yingjie; Wang Lei; Tong Yunfu

    2010-01-01

    It designs a portable x-ray fluorescence analyzer based on PDA. The high performance Single Chip Microcomputer-C8051F060 works as the core controller on the measure-control board. The communication between PDA and measure-control board is based on Bluetooth technology. Benefiting from the rich resource on the chip of C8051F060, it's very easy to design the MCA (Multi-Channel Analyzer), detection-control circuit, peak-detection circuit compactly. WinCE OS runs on the PDA, and the analysis software is designed on the Visual Studio2005 in C++. The power of the system is supplied by the lithium battery. (authors)

  5. Analysis of chaos in high-dimensional wind power system.

    Science.gov (United States)

    Wang, Cong; Zhang, Hongli; Fan, Wenhui; Ma, Ping

    2018-01-01

    A comprehensive analysis on the chaos of a high-dimensional wind power system is performed in this study. A high-dimensional wind power system is more complex than most power systems. An 11-dimensional wind power system proposed by Huang, which has not been analyzed in previous studies, is investigated. When the systems are affected by external disturbances including single parameter and periodic disturbance, or its parameters changed, chaotic dynamics of the wind power system is analyzed and chaotic parameters ranges are obtained. Chaos existence is confirmed by calculation and analysis of all state variables' Lyapunov exponents and the state variable sequence diagram. Theoretical analysis and numerical simulations show that the wind power system chaos will occur when parameter variations and external disturbances change to a certain degree.

  6. Human Powered PiezoelectricBatteries to Supply Power to Wearable Electronic Devices.

    OpenAIRE

    Gonzalez, Jose' Luis; Rubio, Antonio; Moll, Francesc

    2002-01-01

    Consumer electronic equipments are becoming small, portable devices that provide users with a wide range of functionality, from communication to music playing. The battery technology and the power consumption of the device limit the size, weight and autonomous lifetime. One promising alternative to batteries (and fuel cells, that must be refueled as well) is to use the parasitic energy dissipated in the movement of the wearer of the device to power it. We analyze in this work the current stat...

  7. Study of the power supply topology with high stability for accelerator

    International Nuclear Information System (INIS)

    Wu Wei; Wang Yunfang; Wang Jiewei

    2005-01-01

    The requirements of the power supply for accelerator are analyzed. A few of topologies of the highly stabilized power supply are discussed. The types are listed: Auto-transformers-diode rectifier-transistor regulating current. Thyristor rectifier regulating voltage -transistor regulating current, Diode rectifier -DC-chopping. Thyristor rectifier regulating voltage -two-quadrant-chopping. The advantages and disadvantages of the topologies for power supply are discussed. The notice questions of the power supply designed for accelerator are analyzed. (authors)

  8. Research on wind power grid-connected operation and dispatching strategies of Liaoning power grid

    Science.gov (United States)

    Han, Qiu; Qu, Zhi; Zhou, Zhi; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Li, Jinze; Ling, Zhaowei

    2018-02-01

    As a kind of clean energy, wind power has gained rapid development in recent years. Liaoning Province has abundant wind resources and the total installed capacity of wind power is in the forefront. With the large-scale wind power grid-connected operation, the contradiction between wind power utilization and peak load regulation of power grid has been more prominent. To this point, starting with the power structure and power grid installation situation of Liaoning power grid, the distribution and the space-time output characteristics of wind farm, the prediction accuracy, the curtailment and the off-grid situation of wind power are analyzed. Based on the deep analysis of the seasonal characteristics of power network load, the composition and distribution of main load are presented. Aiming at the problem between the acceptance of wind power and power grid adjustment, the scheduling strategies are given, including unit maintenance scheduling, spinning reserve, energy storage equipment settings by the analysis of the operation characteristics and the response time of thermal power units and hydroelectric units, which can meet the demand of wind power acceptance and provide a solution to improve the level of power grid dispatching.

  9. Estimating the impacts of wind power on power systems—summary of IEA Wind collaboration

    Science.gov (United States)

    Holttinen, Hannele

    2008-04-01

    Adding wind power to power systems will have beneficial impacts by reducing the emissions of electricity production and reducing the operational costs of the power system as less fuel is consumed in conventional power plants. Wind power will also have a capacity value to a power system. However, possible negative impacts will have to be assessed to make sure that they will only offset a small part of the benefits and also to ensure the security of the power system operation. An international forum for the exchange of knowledge of power system impacts of wind power has been formed under the IEA Implementing Agreement on Wind Energy. The Task 'Design and Operation of Power Systems with Large Amounts of Wind Power' is analyzing existing case studies from different power systems. There are a multitude of studies completed and ongoing related to the cost of wind integration. However, the results are not easy to compare. This paper describes the general issues of wind power impacts on power systems and presents a comparison of results from ten case studies on increased balancing needs due to wind power.

  10. Estimating the impacts of wind power on power systems-summary of IEA Wind collaboration

    International Nuclear Information System (INIS)

    Holttinen, Hannele

    2008-01-01

    Adding wind power to power systems will have beneficial impacts by reducing the emissions of electricity production and reducing the operational costs of the power system as less fuel is consumed in conventional power plants. Wind power will also have a capacity value to a power system. However, possible negative impacts will have to be assessed to make sure that they will only offset a small part of the benefits and also to ensure the security of the power system operation. An international forum for the exchange of knowledge of power system impacts of wind power has been formed under the IEA Implementing Agreement on Wind Energy. The Task 'Design and Operation of Power Systems with Large Amounts of Wind Power' is analyzing existing case studies from different power systems. There are a multitude of studies completed and ongoing related to the cost of wind integration. However, the results are not easy to compare. This paper describes the general issues of wind power impacts on power systems and presents a comparison of results from ten case studies on increased balancing needs due to wind power

  11. Tensor analyzing power T20 of the dd →3Hen and dd →3Hp reactions at zero angle for energies 140, 200, and 270 MeV

    International Nuclear Information System (INIS)

    Ladygin, V. P.; Uesaka, T.; Saito, T.; Hatano, M.; Isupov, A. Yu.; Kato, H.; Ladygina, N. B.; Maeda, Y.; Malakhov, A. I.; Nishikawa, J.; Ohnishi, T.; Okamura, H.; Reznikov, S. G.; Sakai, H.; Sakamoto, N.; Sakoda, S.; Satou, Y.; Sekiguchi, K.; Suda, K.; Tamii, A.

    2006-01-01

    RIKEN Accelerator Research Facility data on the tensor analyzing power T 20 of the dd → 3 Hen and dd → 3 Hp reactions at zero angle for deuteron kinetic energies of 140, 200, and 270 MeV are reported. The observed positive sign of T 20 clearly demonstrates the sensitivity to the D/S-wave ratio in the 3 He and 3 H wave functions in the energy range of the experiment. Data on T 20 for the 3 Hen channel are in agreement with those for the 3 Hp channel within the experimental errors

  12. The wireshark field guide analyzing and troubleshooting network traffic

    CERN Document Server

    Shimonski, Robert

    2013-01-01

    The Wireshark Field Guide provides hackers, pen testers, and network administrators with practical guidance on capturing and interactively browsing computer network traffic. Wireshark is the world's foremost network protocol analyzer, with a rich feature set that includes deep inspection of hundreds of protocols, live capture, offline analysis and many other features. The Wireshark Field Guide covers the installation, configuration and use of this powerful multi-platform tool. The book give readers the hands-on skills to be more productive with Wireshark as they drill

  13. Studying dynamics of indicators of nuclear power stations exploitation (the case of US nuclear power stations)

    OpenAIRE

    Varshavsky, Leonid

    2013-01-01

    Analysis of external and internal factors influencing significant improvement of economic indicators of US nuclear power stations in the 1990s is carried out. Approaches to modeling dynamics of capacity factors of nuclear power stations are proposed. Comparative analysis of dynamics of capacity factors and occupational radiation exposure for various generations of US nuclear power plants is carried out. Dynamical characteristics of «learning by doing» effects for analyzed indicators are measu...

  14. Analysis of public attitude to nuclear power

    International Nuclear Information System (INIS)

    Trofimenko, A.P.; Pisanko, Zh.I.

    2001-01-01

    Psychological features of nuclear power public perception, reasons of anti-nuclear movement and social components of its participants are considered. The results of some public opinion polls on nuclear power are analyzed, and factors, which influence on opinion, are discussed. Arguments are presented which indicate that part population imagination about nuclear power hazard is strongly exaggerated

  15. HVDC transmission from isorated nuclear power plant

    International Nuclear Information System (INIS)

    Takenaka, Kiyoshi; Takasaki, Masahiro; Ichikawa, Tatemi; Hayashi, Toshiyuki

    1985-01-01

    HVDC transmission directly from nuclear power plant is considered as one of the patterns of long distance and large capacity transmission system. This reports considers two route HVDC transmission from PWR type nuclear power plant, and analyzes dynamic response characteristics due to bus fault, main protection failure and etc. using the AC-DC Power System Simulator. (author)

  16. Millimeter-wave power amplifiers

    CERN Document Server

    du Preez, Jaco

    2017-01-01

    This book provides a detailed review of millimeter-wave power amplifiers, discussing design issues and performance limitations commonly encountered in light of the latest research. Power amplifiers, which are able to provide high levels of output power and linearity while being easily integrated with surrounding circuitry, are a crucial component in wireless microwave systems. The book is divided into three parts, the first of which introduces readers to mm-wave wireless systems and power amplifiers. In turn, the second focuses on design principles and EDA concepts, while the third discusses future trends in power amplifier research. The book provides essential information on mm-wave power amplifier theory, as well as the implementation options and technologies involved in their effective design, equipping researchers, circuit designers and practicing engineers to design, model, analyze, test and implement high-performance, spectrally clean and energy-efficient mm-wave systems.

  17. Isolated Power Generation System Using Permanent Magnet Synchronous Generator with Improved Power Quality

    Science.gov (United States)

    Arya, Sabha Raj; Patel, Ashish; Giri, Ashutosh

    2018-03-01

    This paper deals wind energy based power generation system using Permanent Magnet Synchronous Generator (PMSG). It is controlled using advanced enhanced phase-lock loop for power quality features using distribution static compensator to eliminate the harmonics and to provide KVAR compensation as well as load balancing. It also manages rated potential at the point of common interface under linear and non-linear loads. In order to have better efficiency and reliable operation of PMSG driven by wind turbine, it is necessary to analyze the governing equation of wind based turbine and PMSG under fixed and variable wind speed. For handling power quality problems, power electronics based shunt connected custom power device is used in three wire system. The simulations in MATLAB/Simulink environment have been carried out in order to demonstrate this model and control approach used for the power quality enhancement. The performance results show the adequate performance of PMSG based power generation system and control algorithm.

  18. Space power plants and power-consuming industrial systems

    International Nuclear Information System (INIS)

    Latyshev, L.; Semashko, N.

    1996-01-01

    An opportunity to create the space power production on the basis of solar, nuclear and fusion energies is analyzed. The priority of solar power production as the most accessible and feasible in comparison with others is emphasized. However, later on, it probably will play an auxiliary role. The possibilities of fusion power production, as a basic one in future, are also considered. It is necessary to create reactors using the fueling cycle with helium-3 (instead of tritium and deuterium, later on). The reaction products--charged particles, mainly--allow one to organize the system of direct fusion energy conversion into electricity. The produced energy is expected not to be transmitted to Earth, but an industry in space is expected to be produced on its basis. The industrial (power and science-consuming) objects located on a whole number of space apparatus will form a single complex with its own basic power plant. The power transmission within the complex will be realized with high power density fluxes of microwave radiation to short distances with their receivers at the objects. The necessary correction of the apparatus positions in the complex will be done with ion and plasma thrusters. The materials present on the Moon, asteroids and on other planets can serve as raw materials for industrial objects. Such an approach will help to improve the ecological state on Earth, to eliminate the necessity in the fast energy consumption growth and to reduce the hazard of global thermal crisis

  19. Energy and nuclear power planning study for Armenia

    International Nuclear Information System (INIS)

    2004-07-01

    The Energy and Nuclear Power Planning (ENPP) study for Armenia has been conducted under the technical cooperation programme of the International Atomic Energy Agency (IAEA). The objective of the study was to analyze the electricity demand as part of the total final energy demand in various scenarios of Armenian socioeconomic and technological development, and to develop economically optimized electric generating system expansion plans for meeting the electric power demand, and to assess the role that nuclear energy could play within these optimal programs. The specific objectives of this study were: to define the role that nuclear power could play in the future electricity supply in Armenia, based on a least-cost expansion planning analysis of the country's power system; to analyze the environmental impacts of such a nuclear power development; to evaluate the financial viability of the envisaged nuclear power development program; to train a group of Armenian experts in the use of the IAEA's energy models

  20. ANALYSIS OF GROSS REGIONAL PRODUCT FLUCTUATIONS AND ELECTRIC POWER CONSUMPTION IN 2005- 2014. RESERVES FOR DECREASING ELECTRIC POWER PRICES

    Directory of Open Access Journals (Sweden)

    Suslov N. I.

    2016-09-01

    Full Text Available In this work we considered the trajectories of change in indicators characterizing the status of economics and power industry: gross regional product, electric power consumption, industrial production, energy prices and costs of delivering electric power to consumers in Russian regions for the last 10 years. Low global commodity prices and sanctions led to a sharp decrease of equipment import, which resulted in an acute problem of import substitution. The level of tariffs of natural monopolies is of great importance for industrial development. The goal of this work was to analyze possibilities for reducing electric power prices by changing the institutional and economic conditions of management. We analyzed not only the official information from Rosstat, but also government regulations, figures given in the official government publication «The Rossiyskaya Gazeta» as well as articles and interviews on economic problems of the electric power industry over the recent years published in «The Kommersant» newspaper. High tariffs of network marketing companies for electric energy transmission, state regulation of heating prices, financing the construction of new capacities by charging the payment in power provision contracts, high price of electric power of nuclear power plants lead to an annual increase in electric power prices for end users. In this work we considered possible solutions to limit the growth of electric power prices.

  1. Field intercomparison of four methane gas analyzers suitable for eddy covariance flux measurements

    Science.gov (United States)

    Peltola, O.; Mammarella, I.; Haapanala, S.; Burba, G.; Vesala, T.

    2013-06-01

    Performances of four methane gas analyzers suitable for eddy covariance measurements are assessed. The assessment and comparison was performed by analyzing eddy covariance data obtained during summer 2010 (1 April to 26 October) at a pristine fen, Siikaneva, Southern Finland. High methane fluxes with pronounced seasonality have been measured at this fen. The four participating methane gas analyzers are commercially available closed-path units TGA-100A (Campbell Scientific Inc., USA), RMT-200 (Los Gatos Research, USA), G1301-f (Picarro Inc., USA) and an early prototype open-path unit Prototype-7700 (LI-COR Biosciences, USA). The RMT-200 functioned most reliably throughout the measurement campaign, during low and high flux periods. Methane fluxes from RMT-200 and G1301-f had the smallest random errors and the fluxes agree remarkably well throughout the measurement campaign. Cospectra and power spectra calculated from RMT-200 and G1301-f data agree well with corresponding temperature spectra during a high flux period. None of the gas analyzers showed statistically significant diurnal variation for methane flux. Prototype-7700 functioned only for a short period of time, over one month, in the beginning of the measurement campaign during low flux period, and thus, its overall accuracy and season-long performance were not assessed. The open-path gas analyzer is a practical choice for measurement sites in remote locations due to its low power demand, whereas for G1301-f methane measurements interference from water vapor is straightforward to correct since the instrument measures both gases simultaneously. In any case, if only the performance in this intercomparison is considered, RMT-200 performed the best and is the recommended choice if a new fast response methane gas analyzer is needed.

  2. Assessment of Power Quality Problems for TRIGA PUSPATI Reactor (RTP)

    International Nuclear Information System (INIS)

    Mohd Fazli Zakaria; Ramachandaramurthy, V.K.

    2016-01-01

    The electrical power systems are exposed to different types of power quality disturbances. Investigation and monitoring of power quality is necessary to maintain accurate operation of sensitive equipment especially for nuclear installations. This paper will discuss the power quality problems observed at the electrical sources of PUSPATI TRIGA Reactor (RTP). Assessment of power quality requires the identification of any anomalous behavior on a power system, which adversely affects the normal operation of electrical or electronic equipment. A power quality assessment involves gathering data resources; analyzing the data (with reference to power quality standards) then, if problems exist, recommendation of mitigation techniques must be considered. Field power quality data is collected by power quality recorder and analyzed with reference to power quality standards. Normally the electrical power is supplied to the RTP via two sources in order to keep a good reliability where each of them is designed to carry the full load. The assessment of power quality during reactor operation was performed for both electrical sources. There were several disturbances such as voltage harmonics and flicker that exceeded the thresholds. (author)

  3. FPGA based high-performance multi-channel analyzer with local histogram memory

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.

    2004-01-01

    Modern nuclear spectroscopy systems demand for a Multi-Channel Analyzer (MCA) with higher resolution, faster speed and other advanced features. The MCA described here is targeted for such demanding applications. The MCA has an in-built local histogram memory and a memory management unit integrated in an FPGA (Field Programmable Gate Array) chip. In addition to the integrated low power digital circuitry, the system utilizes state of the art advanced analog circuits like low power, high speed and high precision comparators, op-amps, ADC and DAC. The operating resolution is selectable from 256 channels to 16384 channels for pulse height analysis. It supports high count rate applications (typically 100 KHz) without significant dead time penalty. It can have an USB bus interface with simple changes. In general, the MCA gives a high performance, compact and low power alternative for portable and battery operated systems as well as for high end laboratory instruments. (author)

  4. Research on spot power market equilibrium model considering the electric power network characteristics

    International Nuclear Information System (INIS)

    Wang, Chengmin; Jiang, Chuanwen; Chen, Qiming

    2007-01-01

    Equilibrium is the optimum operational condition for the power market by economics rule. A realistic spot power market cannot achieve the equilibrium condition due to network losses and congestions. The impact of the network losses and congestion on spot power market is analyzed in this paper in order to establish a new equilibrium model considering the network loss and transmission constraints. The OPF problem formulated according to the new equilibrium model is solved by means of the equal price principle. A case study on the IEEE-30-bus system is provided in order to prove the effectiveness of the proposed approach. (author)

  5. CO2 Price Impacts on Nuclear Power Plant Competitiveness in Croatia

    International Nuclear Information System (INIS)

    Tomsic, Z.; Pasicko, R.

    2010-01-01

    Long term power system planning faces growing number of concerns and uncertainties, which is especially true for nuclear power plants due to their high investment costs and financial risk. In order to analyze competitiveness of nuclear power plants and optimize energy mix, existing models are not sufficient anymore and planners need to think differently in order to face these challenges. Croatia will join EU ETS (European Emission Trading Scheme) with accession to EU (probably in 2012). Thus, for Croatian electrical system it is very important to analyze possible impacts of CO 2 emissions. Analysis presented in this paper is done by electricity market simulation model PLEXOS which was used for modelling Croatian electrical system during development of the Croatian Energy Strategy in 2008. Paper analyzes impacts of CO 2 price on competitiveness of nuclear power plant within Croatian power system between 2020 and 2025. Analyzes are focused on how nuclear power plant influences total emission from the power system regarding coal and gas prices, average electricity price regarding CO 2 , coal and gas prices price. Results of this paper are showing that with emissions from Energy strategy development scenario with two new coal power plants (600 MW each) and two new gas power plants (400 MW each) until 2020, Croatia does not meet Kyoto target due to this emissions from power system. On the other side, introduction of nuclear power plants presented in this paper (1000 MW instead of one coal and one gas power plant) means nearly 6.5 Mt CO 2 emissions less annually and gives possibility to achieve Kyoto target (as this reduced amount represents nearly 22 % of Croatian Kyoto target). Results are also showing how increase in CO 2 price is enhancing competitiveness of a nuclear power plant.(author).

  6. Operating modes and practical power flow analysis of bidirectional isolated power interface for distributed power systems

    International Nuclear Information System (INIS)

    Wen, Huiqing; Su, Bin

    2016-01-01

    Highlights: • Four operating modes of Dual-Phase-Shift control for Dual Active Bridge converter are presented. • Effects of “minor parameters” such as the deadtime and power device voltage drops are analyzed. • Accurate power flow models with Dual-Phase-Shift control are developed and verified with experimental results. • Optimal operating mode is determined with respect to the efficiency improvement. • Measured efficiency of the Dual Active Bridge converter is improved up to 14%. - Abstract: Due to the intermittent nature of the renewable energy sources including photovoltaic and wind energy, the energy storage systems are essential to stabilize dc bus voltage. Considering the discharge depth of super-capacitors and energy-storage batteries, the bidirectional isolated power interface will operate for a wide range of voltage and power. This study focuses on in-depth analysis of the dual-active-bridge dc–dc converter that is controlled by the dual-phase-shift scheme to improve the conversion efficiency in distributed power system. The power flow of each operating mode with dual-phase-shift control is characterized based on a detailed analysis of the effects of “minor parameters”, including the deadtime and power device voltage drops. The complete output power plane of the dual-active-bridge converter with dual-phase-shift control is obtained and compared with experimental results. The optimal operating mode is determined according to the practical output power range and the power flow characteristics. Experimental evaluation shows the effectiveness of the proposed power flow model with dual-phase-shift control and significant efficiency improvement using the optimal mode of dual-phase-shift compared with the conventional phase shift control.

  7. A Meteorological Information Mining-Based Wind Speed Model for Adequacy Assessment of Power Systems With Wind Power

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    Accurate wind speed simulation is an essential prerequisite to analyze the power systems with wind power. A wind speed model considering meteorological conditions and seasonal variations is proposed in this paper. Firstly, using the path analysis method, the influence weights of meteorological...... systems with wind power. The assessment results of the modified IEEE-RTS79 and IEEE-RTS96 demonstrated the effectiveness and accuracy of the proposed model....

  8. Historical civilian nuclear accident based Nuclear Reactor Condition Analyzer

    Science.gov (United States)

    McCoy, Kaylyn Marie

    There are significant challenges to successfully monitoring multiple processes within a nuclear reactor facility. The evidence for this observation can be seen in the historical civilian nuclear incidents that have occurred with similar initiating conditions and sequences of events. Because there is a current lack within the nuclear industry, with regards to the monitoring of internal sensors across multiple processes for patterns of failure, this study has developed a program that is directed at accomplishing that charge through an innovation that monitors these systems simultaneously. The inclusion of digital sensor technology within the nuclear industry has appreciably increased computer systems' capabilities to manipulate sensor signals, thus making the satisfaction of these monitoring challenges possible. One such manipulation to signal data has been explored in this study. The Nuclear Reactor Condition Analyzer (NRCA) program that has been developed for this research, with the assistance of the Nuclear Regulatory Commission's Graduate Fellowship, utilizes one-norm distance and kernel weighting equations to normalize all nuclear reactor parameters under the program's analysis. This normalization allows the program to set more consistent parameter value thresholds for a more simplified approach to analyzing the condition of the nuclear reactor under its scrutiny. The product of this research provides a means for the nuclear industry to implement a safety and monitoring program that can oversee the system parameters of a nuclear power reactor facility, like that of a nuclear power plant.

  9. Does environmental impact assessment really support technological change? Analyzing alternatives to coal-fired power stations in Denmark

    International Nuclear Information System (INIS)

    Lund, H.; Hvelplund, F.

    1997-01-01

    Danish energy policy calls for development of decentralized, cleaner technologies to replace conventional power stations and, since 1990, aims to reduce CO 2 emissions in 2005 to 20% below their 1988 level. These political goals require a technological change, from conventional, central power stations to cleaner, decentralized technologies such as energy conservation, cogeneration, and renewable energy. In principle, environmental impact assessment (EIA) supports this change on a project-by-project basis. The EU directive on EIA was based on the preventive principle: to eliminate pollution source rather than attempting to counteract it subsequently. According to the Danish implementation of the directive, an EIA must review a project's main alternatives and the environmental consequences of the alternatives. If this were done properly, EIAs could assist Denmark in meeting its CO 2 reduction goals. However, because EIA is implemented on a restricted, regional basis, it does not support technological change. Responsibility for the preparation of the EIA is given to the regional authorities through a law which does not require alternatives to be assessed that extend geographically beyond the boundaries of a regional authority. Thus, there is no certainty of serious analysis of cleaner technology alternatives to large coal-fired power stations. This conclusion is based on examination of three case studies using a participatory research method

  10. Power-Consumption Measurements for LTE User Equipment

    DEFF Research Database (Denmark)

    Lauridsen, Mads

    wireless communications test set and the Agilent N6705B DC power analyzer to establish a power consumption model for LTE user equipment (UE). The model is useful when you need to examine the UE battery life in system-level simulations. We will explain how the Agilent equipment can be used in manual tests......, but we do not discuss how to make automated tests (for example, using VEE software). In this application note, we analyze smartphones adhering to the 3GPP LTE standard [1]....

  11. A high resolution 16 k multi-channel analyzer PC add-on card

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Paulson, Molly; Vaidya, P.P.

    2001-01-01

    This paper describes the system details of a 16 K channel resolution Multi-Channel Analyzer (MCA) developed at Electronics Division, BARC, which is used in high resolution nuclear spectroscopy systems for pulse height analysis. The high resolution data acquisition PC add-on card is architectured using a state of the art digital circuit design technology which makes use of a Field Programmable Gate Array (FPGA), and some of the most modern and advanced analog counterparts like low power, high speed and high precision comparators, Op-amps, ADCs and DACs etc. The 16 K MCA card gives an economic, compact, and low power alternative for nuclear pulse spectroscopy use. (author)

  12. Risk Assessment of Power System considering the CPS of Transformers

    Science.gov (United States)

    Zhou, Long; Peng, Zewu; Liu, Xindong; Li, Canbing; Chen, Can

    2018-02-01

    This paper constructs a risk assessment framework of power system for device-level information security, analyzes the typical protection configuration of power transformers, and takes transformer gas protection and differential protection as examples to put forward a method that analyzes the cyber security in electric power system, which targets transformer protection parameters. We estimate the risk of power system accounting for the cyber security of transformer through utilizing Monte Carlo method and two indexes, which are the loss of load probability and the expected demand not supplied. The proposed approach is tested with IEEE 9 bus system and IEEE 118 bus system.

  13. The electric power trading. The stakes and forecasts of the electric power trading at the time of Enron's failure

    International Nuclear Information System (INIS)

    2002-10-01

    This study on the electric power trading analyzes the Change and trading mechanisms, the trading part in the european market, identifies the risk and the opportunities of the trading and analyzes the enterprises mastership. (A.L.B.)

  14. Comparison of analyzing power and polarization in the reaction /sup 3/H(p,n)/sup 3/He. Pt. 2. New polarization results below 4 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W.; Byrd, R.C.; Lisowski, P.W.; Walter, R.L. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA)); Donoghue, T.R. (Ohio State Univ., Columbus (USA). Dept. of Physics)

    1981-11-30

    The polarization Psup(y) for the /sup 3/H(p,n)/sup 3/He reaction was measured for energies between 2 and 4 MeV. Special care was given to minimizing the effects of background and to interpreting the experimental spectra. The new values for Psup(y) are significantly higher than previous values, and comparison to the available data for the analyzing power Asub(y) for the same reaction now shows that in this energy range Psup(y) ad Asub(y) are equal within experimental uncertainties. This equality negates earlier conclusions that sizeable differences existed between these observables. In particular, our new results demonstrate that in this reaction the effects of charge symmetry breaking on differences between these observables must be small.

  15. Point-of-care, portable microfluidic blood analyzer system

    Science.gov (United States)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  16. Life Cycle Assessment of a HYSOL Concentrated Solar Power Plant: Analyzing the Effect of Geographic Location

    Directory of Open Access Journals (Sweden)

    Blanca Corona

    2016-05-01

    Full Text Available Concentrating Solar Power (CSP technology is developing in order to achieve higher energy efficiency, reduced economic costs, and improved firmness and dispatchability in the generation of power on demand. To this purpose, a research project titled HYSOL has developed a new power plant, consisting of a combined cycle configuration with a 100 MWe steam turbine and an 80 MWe gas-fed turbine with biomethane. Technological developments must be supported by the identification, quantification, and evaluation of the environmental impacts produced. The aim of this paper is to evaluate the environmental performance of a CSP plant based on HYSOL technology using a Life Cycle Assessment (LCA methodology while considering different locations. The scenarios investigated include different geographic locations (Spain, Chile, Kingdom of Saudi Arabia, Mexico, and South Africa, an alternative modelling procedure for biomethane, and the use of natural gas as an alternative fuel. Results indicate that the geographic location has a significant influence on the environmental profile of the HYSOL CSP plant. The results obtained for the HYSOL configuration located in different countries presented significant differences (between 35% and 43%, depending on the category, especially in climate change and water stress categories. The differences are mainly attributable to the local availability of solar and water resources and composition of the national electricity mix. In addition, HYSOL technology performs significantly better when hybridizing with biomethane instead of natural gas. This evidence is particularly relevant in the climate change category, where biomethane hybridization emits 27.9–45.9 kg CO2 eq per MWh (depending on the biomethane modelling scenario and natural gas scenario emits 264 kg CO2 eq/MWh.

  17. Strengthening of nuclear power plant construction safety management

    International Nuclear Information System (INIS)

    Yu Jun

    2012-01-01

    The article describes the warning of the Fukushima nuclear accident, and analyzes the major nuclear safety issues in nuclear power development in China, problems in nuclear power plants under construction, and how to strengthen supervision and management in nuclear power construction. It also points out that the development of nuclear power must attach great importance to the safety, and nuclear power plant construction should strictly implement the principle of 'safety first and quality first'. (author)

  18. Electric power trading. The first study on stakes and consequences of power trading

    International Nuclear Information System (INIS)

    2000-06-01

    Power trading (purchase/sale of electricity on a stock exchange) is an emerging activity in continental Europe while it already came to maturity in the US, in the UK and in Scandinavia. Several stock exchanges have opened since 1988, in particular in Germany, Spain and in The Netherlands. New projects of creation are under study, except in France where public authorities remain reticent with respect to this evolution. Power trade is deeply overturning the organization of power markets with offering an alternative to the direct supply from producers and distributors. This study presents the functioning modes of the main stock exchanges in operation today. It analyzes the stakes of power trade for all intervening parties of the market (historical actors, newcomers and consumers). The situation and the strategic behaviour of 12 key-actors of the power sector are also examined. (J.S.)

  19. Analysis on the power and efficiency in wireless power transfer system via coupled magnetic resonances

    Science.gov (United States)

    Liu, Mingjie

    2018-06-01

    The analysis of characteristics of the power and efficiency in wireless power transmission (WPT) system is the theoretical basis of magnetic coupling resonant wireless power transmission (MCR-WPT) technology. The electromagnetic field theory was employed to study the variation of the coupling degree of the two electromagnetic coils with the parameters of the coils. The equivalent circuit was used to analyze the influence of different factors on the transmission power and efficiency of the WPT system. The results show that there is an optimal radius ratio between the two coils, which makes the mutual inductance of the coils the largest. Moreover, when the WPT system operates in the under-coupling state, the transmission power of the system drops sharply, and there is a frequency splitting of the power when in the over-coupling state.

  20. Limits to power system growth

    International Nuclear Information System (INIS)

    Slater, S.M.; Klein, A.C.; Webb, B.J.; Pauley, K.A.

    1993-01-01

    In the design of space nuclear power systems a variety of conversion techniques may be used, each with its own advantages and disadvantages. A study was performed which analyzed over 120 proposed system designs. The designs were compared to identify the optimum conversion system as a function of power level and find limits to specific mass (kg/kWe) for each power cycle. Furthermore, the component masses were studied to determine which component of the overall design contributes the most to total system mass over a variety of power levels. The results can provide a focus for future research efforts by selecting the best conversion technology for the desired power range, and optimizing the system component which contributes most to the total mass

  1. Output power analyses for the thermodynamic cycles of thermal power plants

    International Nuclear Information System (INIS)

    Sun Chen; Cheng Xue-Tao; Liang Xin-Gang

    2014-01-01

    Thermal power plant is one of the important thermodynamic devices, which is very common in all kinds of power generation systems. In this paper, we use a new concept, entransy loss, as well as exergy destruction, to analyze the single reheating Rankine cycle unit and the single stage steam extraction regenerative Rankine cycle unit in power plants. This is the first time that the concept of entransy loss is applied to the analysis of the power plant Rankine cycles with reheating and steam extraction regeneration. In order to obtain the maximum output power, the operating conditions under variant vapor mass flow rates are optimized numerically, as well as the combustion temperatures and the off-design flow rates of the flue gas. The relationship between the output power and the exergy destruction rate and that between the output power and the entransy loss rate are discussed. It is found that both the minimum exergy destruction rate and the maximum entransy loss rate lead to the maximum output power when the combustion temperature and heat capacity flow rate of the flue gas are prescribed. Unlike the minimum exergy destruction rate, the maximum entransy loss rate is related to the maximum output power when the highest temperature and heat capacity flow rate of the flue gas are not prescribed. (general)

  2. Optimal control systems in hydro power plants

    International Nuclear Information System (INIS)

    Babunski, Darko L.

    2012-01-01

    The aim of the research done in this work is focused on obtaining the optimal models of hydro turbine including auxiliary equipment, analysis of governors for hydro power plants and analysis and design of optimal control laws that can be easily applicable in real hydro power plants. The methodology of the research and realization of the set goals consist of the following steps: scope of the models of hydro turbine, and their modification using experimental data; verification of analyzed models and comparison of advantages and disadvantages of analyzed models, with proposal of turbine model for design of control low; analysis of proportional-integral-derivative control with fixed parameters and gain scheduling and nonlinear control; analysis of dynamic characteristics of turbine model including control and comparison of parameters of simulated system with experimental data; design of optimal control of hydro power plant considering proposed cost function and verification of optimal control law with load rejection measured data. The hydro power plant models, including model of power grid are simulated in case of island ing and restoration after breakup and load rejection with consideration of real loading and unloading of hydro power plant. Finally, simulations provide optimal values of control parameters, stability boundaries and results easily applicable to real hydro power plants. (author)

  3. Power supply design for Hadron Facility

    International Nuclear Information System (INIS)

    Karady, G.; Kansog, J.; Thiessen, H.A.; Schneider, E.

    1987-01-01

    Recently, a study investigated the feasibility of building a large 60 GeV, kaon factory accelerator. This paper presents the conceptual design of the magnet power supplies and energy storage system. In this study the following three systems were investigated: (a) power supply using storage generator; (b) power supply using inductive storage device; and (c) resonant power supplies. These systems were analyzed from both technical and economical points of view. It was found that all three systems are feasible and can be built using commercially available components. From a technical point of view, the system using inductive storage is the most advantageous. The resonant power supply is the most economical solution

  4. The tensor analyzing power T20 in the dd → 3Hen and dd → 3Hp reactions at the energies 140, 200 and 270 MeV at zero angle

    International Nuclear Information System (INIS)

    Ladygin, V.P.; ); Uesaka, T.; Saito, T.

    2006-01-01

    The data on the tensor analyzing power T 20 in the dd → 3 Hen and dd → 3 Hp reactions at 140, 200 and 270 MeV of the deuteron kinetic energy and at zero angle obtained at RIKEN Accelerator Research Facility are presented. The observed positive sign of T 20 clearly demonstrates the sensitivity to the D/S wave ratios in the 3 He and 3 H in the energy domain of the measurements. The T 20 data for the 3 Hen and 3 Hp channels are in agreement within experimental accuracy [ru

  5. A preliminary design and BOP cost analysis of M-C Power`s MCFC commerical unit

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.P. [Bechtel Corp, San Francisco, CA (United States)

    1996-12-31

    M-C Power Corporation plans to introduce its molten carbonate fuel cell (MCFC) market entry unit in the year 2000 for distributed and on-site power generation. Extensive efforts have been made to analyze the cell stack manufacturing costs. The major objective of this study is to conduct a detailed analysis of BOP costs based on an initial design of the market entry unit.

  6. Analyze the factors effecting the development of hydro power projects in hydro rich regions of India

    Directory of Open Access Journals (Sweden)

    Ameesh Kumar Sharma

    2016-09-01

    Full Text Available Power is considered as the major back bone for all the nations throughout the world including India on the basis of which development of the country depends. If a country has the resources to generate the power at competitive price in that case the people of the country get the benefits in terms of improvement in their social and economical life. When we talk about India, various locations in the country where still there is no electricity people are living in dark without having the access of the modern technology. The total hydro power potential of India is 1, 50,000 MW out of this total hydro potential only 40,195 MW is exploited till 2014. More than 80% of the total hydro potential of the country is lying in the western Himalayan states (Jammu and Kashmir, Himachal Pradesh, Uttrakhand and Arunachal Pradesh. Small hydro projects are also playing a very important role in the modern world for the development of the remote areas which are not main grid connected specially in western Himalayan region of India. India has a total potential 19,749 MW of small hydro projects and of this total potential only 3990.9 MW harnessed till 2014. Ministry of new and renewable energy in India is also providing special incentives to hydro rich states of India. In this research article we are taken the case study of the small hydro projects in the western Himalayan region because theses states are having vast small hydro potential which is still needed to be harnessed. So, it is very important to identify the factors which are effecting the development of these small ventures especially in western Himalayan region in India.

  7. SUBWAY POWER SYSTEMS WITH MODERN SEMICONDUCTOR CONVERTERS AND ENERGY STORAGE DEVICES

    Directory of Open Access Journals (Sweden)

    O.I. Kholod

    2013-02-01

    Full Text Available Five subway power systems, a traditional power system and power systems with an active rectifier and an energy storage device, are considered. Estimation of energy loss in the analyzed subway power systems circuits is made.

  8. Method for analysing the adequacy of electric power systems with wind power plants and energy storages

    Directory of Open Access Journals (Sweden)

    Perzhabinsky Sergey

    2017-01-01

    Full Text Available Currently, renewable energy sources and energy storage devices are actively introduced into electric power systems. We developed method to analyze the adequacy of these electric power systems. The method takes into account the uncertainty of electricity generation by wind power plants and the processes of energy storage. The method is based on the Monte Carlo method and allowed to use of long-term meteorological data in open access. The performed experimental research of electrical power system is constructed on the basis of the real technical and meteorological data. The method allows to estimate of effectiveness of introducing generators based on renewable energy sources and energy storages in electric power systems.

  9. Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses.

    Science.gov (United States)

    Faul, Franz; Erdfelder, Edgar; Buchner, Axel; Lang, Albert-Georg

    2009-11-01

    G*Power is a free power analysis program for a variety of statistical tests. We present extensions and improvements of the version introduced by Faul, Erdfelder, Lang, and Buchner (2007) in the domain of correlation and regression analyses. In the new version, we have added procedures to analyze the power of tests based on (1) single-sample tetrachoric correlations, (2) comparisons of dependent correlations, (3) bivariate linear regression, (4) multiple linear regression based on the random predictor model, (5) logistic regression, and (6) Poisson regression. We describe these new features and provide a brief introduction to their scope and handling.

  10. [Michel Foucault and the persistence of psychiatric power].

    Science.gov (United States)

    Caponi, Sandra

    2009-01-01

    This article aims studying the course held by Michel Foucault at the Collège de France in 1973-1974. The records of this course were published in 2003 under the name ' Psychiatric power' . The objective was to compare the different ways in which Foucault analyzes the question of madness in ' Psychiatric power' and in ' History of Madness in the Classical Age' (1961). It is a comparative study about the different ways of analyzing madness developed by Michel Foucault during the archeological and genealogic periods of his work. The absence of the body; binary diagnosis; the description of the surface of symptoms; the classification of diseases more similar to the botanical classification than to pathology; the process of cure directly linked to restitution of behaviors and moral values; as well as the over-power of the psychiatrist, seem to speak about the persistence of an old model of power, a pre-modern and pre-capitalist model, a residue of the old sovereign power.

  11. Phasor Measurement Units in the Eastern Danish power system

    DEFF Research Database (Denmark)

    Nielsen, Arne Hejde; Pedersen, Knud Ole Helgesen; Jørgensen, Preben

    2006-01-01

    Technology. After power system events data can be extracted and analyzed offline. The purpose of the project is to do research within various utilizations of PMU data. On 8 January 2005 a severe storm passed Denmark, and wind speeds were so high, that wind turbines disconnected from the transmission grid...... because of their self protection. Nysted offshore wind farm was among the wind power units that disconnected from the grid, and PMU data from that event are analyzed. The case illustrates the close relation between voltages, power flows and voltage phase angles over a wide area. The voltage phase angle...

  12. A master system for power system fault phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Myung Ho; Jang, Sang Ho; Hong, Joon Hee; Min, Wan Ki; Yoo, Chang Hwan [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    This report includes as follows - Real time digital simulator - Remote measuring, analyzing and reproducing system of power system fault data -Power system reduction method program using EMTP -Test system for protection device. (author). 22 refs., 38 figs.

  13. Development of turbine cycle performance analyzer using intelligent data mining

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Gyun Young

    2004-02-15

    In recent year, the performance enhancement of turbine cycle in nuclear power plants is being highlighted because of worldwide deregulation environment. Especially the first target of operating plants became the reduction of operating cost to compete other power plants. It is known that overhaul interval is closely related to operating cost Author identified that the rapid and reliable performance tests, analysis, and diagnosis play an important role in the control of overhaul interval through field investigation. First the technical road map was proposed to clearly set up the objectives. The controversial issues were summarized into data gathering, analysis tool, and diagnosis method. Author proposed the integrated solution on the basis of intelligent data mining techniques. For the reliable data gathering, the state analyzer composed of statistical regression, wavelet analysis, and neural network was developed. The role of the state analyzer is to estimate unmeasured data and to increase the reliability of the collected data. For the advanced performance analysis, performance analysis toolbox was developed. The purpose of this tool makes analysis process easier and more accurate by providing three novel heat balance diagrams. This tool includes the state analyzer and turbine cycle simulation code. In diagnosis module, the probabilistic technique based on Bayesian network model and the deterministic technique based on algebraical model are provided together. It compromises the uncertainty in diagnosis process and the pin-point capability. All the modules were validated by simulated data as well as actual test data, and some modules are used as industrial applications. We have a lot of thing to be improved in turbine cycle in order to increase plant availability. This study was accomplished to remind the concern about the importance of turbine cycle and to propose the solutions on the basis of academic as well as industrial needs.

  14. Development of turbine cycle performance analyzer using intelligent data mining

    International Nuclear Information System (INIS)

    Heo, Gyun Young

    2004-02-01

    In recent year, the performance enhancement of turbine cycle in nuclear power plants is being highlighted because of worldwide deregulation environment. Especially the first target of operating plants became the reduction of operating cost to compete other power plants. It is known that overhaul interval is closely related to operating cost Author identified that the rapid and reliable performance tests, analysis, and diagnosis play an important role in the control of overhaul interval through field investigation. First the technical road map was proposed to clearly set up the objectives. The controversial issues were summarized into data gathering, analysis tool, and diagnosis method. Author proposed the integrated solution on the basis of intelligent data mining techniques. For the reliable data gathering, the state analyzer composed of statistical regression, wavelet analysis, and neural network was developed. The role of the state analyzer is to estimate unmeasured data and to increase the reliability of the collected data. For the advanced performance analysis, performance analysis toolbox was developed. The purpose of this tool makes analysis process easier and more accurate by providing three novel heat balance diagrams. This tool includes the state analyzer and turbine cycle simulation code. In diagnosis module, the probabilistic technique based on Bayesian network model and the deterministic technique based on algebraical model are provided together. It compromises the uncertainty in diagnosis process and the pin-point capability. All the modules were validated by simulated data as well as actual test data, and some modules are used as industrial applications. We have a lot of thing to be improved in turbine cycle in order to increase plant availability. This study was accomplished to remind the concern about the importance of turbine cycle and to propose the solutions on the basis of academic as well as industrial needs

  15. Maximum Safety Regenerative Power Tracking for DC Traction Power Systems

    Directory of Open Access Journals (Sweden)

    Guifu Du

    2017-02-01

    Full Text Available Direct current (DC traction power systems are widely used in metro transport systems, with running rails usually being used as return conductors. When traction current flows through the running rails, a potential voltage known as “rail potential” is generated between the rails and ground. Currently, abnormal rises of rail potential exist in many railway lines during the operation of railway systems. Excessively high rail potentials pose a threat to human life and to devices connected to the rails. In this paper, the effect of regenerative power distribution on rail potential is analyzed. Maximum safety regenerative power tracking is proposed for the control of maximum absolute rail potential and energy consumption during the operation of DC traction power systems. The dwell time of multiple trains at each station and the trigger voltage of the regenerative energy absorbing device (READ are optimized based on an improved particle swarm optimization (PSO algorithm to manage the distribution of regenerative power. In this way, the maximum absolute rail potential and energy consumption of DC traction power systems can be reduced. The operation data of Guangzhou Metro Line 2 are used in the simulations, and the results show that the scheme can reduce the maximum absolute rail potential and energy consumption effectively and guarantee the safety in energy saving of DC traction power systems.

  16. Nuclear plant analyzer desktop workstation

    International Nuclear Information System (INIS)

    Beelman, R.J.

    1990-01-01

    In 1983 the U.S. Nuclear Regulatory Commission (USNRC) commissioned the Idaho National Engineering Laboratory (INEL) to develop a Nuclear Plant Analyzer (NPA). The NPA was envisioned as a graphical aid to assist reactor safety analysts in comprehending the results of thermal-hydraulic code calculations. The development was to proceed in three distinct phases culminating in a desktop reactor safety workstation. The desktop NPA is now complete. The desktop NPA is a microcomputer based reactor transient simulation, visualization and analysis tool developed at INEL to assist an analyst in evaluating the transient behavior of nuclear power plants by means of graphic displays. The NPA desktop workstation integrates advanced reactor simulation codes with online computer graphics allowing reactor plant transient simulation and graphical presentation of results. The graphics software, written exclusively in ANSI standard C and FORTRAN 77 and implemented over the UNIX/X-windows operating environment, is modular and is designed to interface to the NRC's suite of advanced thermal-hydraulic codes to the extent allowed by that code. Currently, full, interactive, desktop NPA capabilities are realized only with RELAP5

  17. Analyzing Multimode Wireless Sensor Networks Using the Network Calculus

    Directory of Open Access Journals (Sweden)

    Xi Jin

    2015-01-01

    Full Text Available The network calculus is a powerful tool to analyze the performance of wireless sensor networks. But the original network calculus can only model the single-mode wireless sensor network. In this paper, we combine the original network calculus with the multimode model to analyze the maximum delay bound of the flow of interest in the multimode wireless sensor network. There are two combined methods A-MM and N-MM. The method A-MM models the whole network as a multimode component, and the method N-MM models each node as a multimode component. We prove that the maximum delay bound computed by the method A-MM is tighter than or equal to that computed by the method N-MM. Experiments show that our proposed methods can significantly decrease the analytical delay bound comparing with the separate flow analysis method. For the large-scale wireless sensor network with 32 thousands of sensor nodes, our proposed methods can decrease about 70% of the analytical delay bound.

  18. Study on the impact of the engineering energy gain and the FPC mass power density on the generation cost of fusion power plant

    International Nuclear Information System (INIS)

    Huang Desuo; Wu Yican

    2004-01-01

    The impact of the engineering energy gain and the fusion-power-core (FPC) mass power density (MPD) on the generation cost of fusion power plant are analyzed based on the economic elasticity approach in this paper. From the functions describing the relationship of the generation cost with the engineering energy gain and the MPD, the elasticity coefficients of the generation cost with the engineering energy gain and the MPD have been derived respectively to analyze their sensitivity to the generation cost and the MPD to the generation cost decreases with increasing the engineering energy gain or the MPD. (authors)

  19. Fiber-optic dipping liquid analyzer: theoretical and experimental study of light transmission

    International Nuclear Information System (INIS)

    Zhou Ai; Liu Zhihai; Yuan Libo

    2009-01-01

    A fiber-optic dipping liquid analyzer (FDLA) is developed for measuring liquid properties such as concentration, refractive index, surface tension, and viscosity. An important feature of the FDLA is that a liquid drop is introduced on the end face of a fiber probe, and the drop can be regarded as a planar-convex lens. The light transmitting path and receiving power are affected by the refractive index of the liquid drop. We present a theoretical and experimental analysis of the light transmission. A mathematical model of receiving power is established based on paraxial refraction imaging and fiber reflective intensity modulation methods. Sucrose-water solutions were tested with the FDLA. The experimental results agree well with the theoretical analysis.

  20. Some consideration on nuclear power development. Topics aroused by U.S. proposed 'Generation IV Nuclear Power System

    International Nuclear Information System (INIS)

    Wang Chuanying; Chen Shiqi

    2001-01-01

    U.S. proposed 'Generation IV Nuclear Power System' concept. Its origin and proposed goals for it are analyzed; goals are compared with requirements of URD. In particular, discussed issues on nuclear fuel cycle and Non-proliferation. A well-considered nuclear power development plan, paying close attention to international trend and considering comprehensively domestic situation, is expected

  1. Measurements of analyzing power for 2H(n,n)2H scattering at 14.1 MeV and comparisons to 2H(p,p)2H

    International Nuclear Information System (INIS)

    Tornow, W.; Byrd, R.C.; Howell, C.R.; Pedroni, R.S.; Walter, R.L.

    1983-01-01

    Data for the analyzing power A/sub y/(theta) for elastic scattering of neutrons from deuterons have been measured at 14.1 MeV for the range from 30 0 to 153 0 (c.m.) to accuracies between +- 0.003 and +- 0.006. The results are compared to previous n-d data at 14 MeV and are in significant disagreement with the most recent measurement. The present data are in excellent agreement with a Faddeev calculation by Doleschall. The data are also very similar to p-d scattering data at 14.1 MeV, although systematic deviations are observed at forward angles and near the maximum of A/sub y/(theta) at 130 0 . Recent calculations indicate that Coulomb effects can explain most of these differences, although some features will require further investigation

  2. Microbial Fuel Cells for Powering Navy Devices

    Science.gov (United States)

    2014-01-20

    specific MFC being analyzed. Figure 3 depicts simulated voltage vs. current plots (black curves) and corresponding power vs. current...Powering Navy Devices 7     Fig. 3 – Simulated voltage vs current and power vs current polarization plots for a two- chamber MFC in which membrane...the anode is generated by fermentation of glucose by other microorganisms in the sediment represented by clostridium in Fig. 4. The products of the

  3. Operation Modeling of Power Systems Integrated with Large-Scale New Energy Power Sources

    Directory of Open Access Journals (Sweden)

    Hui Li

    2016-10-01

    Full Text Available In the most current methods of probabilistic power system production simulation, the output characteristics of new energy power generation (NEPG has not been comprehensively considered. In this paper, the power output characteristics of wind power generation and photovoltaic power generation are firstly analyzed based on statistical methods according to their historical operating data. Then the characteristic indexes and the filtering principle of the NEPG historical output scenarios are introduced with the confidence level, and the calculation model of NEPG’s credible capacity is proposed. Based on this, taking the minimum production costs or the best energy-saving and emission-reduction effect as the optimization objective, the power system operation model with large-scale integration of new energy power generation (NEPG is established considering the power balance, the electricity balance and the peak balance. Besides, the constraints of the operating characteristics of different power generation types, the maintenance schedule, the load reservation, the emergency reservation, the water abandonment and the transmitting capacity between different areas are also considered. With the proposed power system operation model, the operation simulations are carried out based on the actual Northwest power grid of China, which resolves the new energy power accommodations considering different system operating conditions. The simulation results well verify the validity of the proposed power system operation model in the accommodation analysis for the power system which is penetrated with large scale NEPG.

  4. Two Understandings of "Soft Power": Prerequisites, Correlates and Consequences

    Directory of Open Access Journals (Sweden)

    Pavel Parshin

    2014-01-01

    Full Text Available The category of "soft power" suggested by Joseph Nye in early 1990s is analyzed in the paper as one of realization of tactile metaphor. Highlighted are those cognitive semantic peculiarities of this metaphor which contribute to its wide popularity and, at the same time, produce prerequisites for two dramatically different understandings of "soft power". According to technological understanding, "soft power" is an instrument or, broader, a technology, especially a communicative one, applied in world politics in such a way as to minimize damage caused to the object of power exertion in comparison to other, "hard power" instruments. In accordance with resource understanding, "soft power" is peculiar to influence exerted by an actor due to his/her/its attractiveness and shared values. The author analyses political and ideological correlates of these two understandings and relates them to different traditions in the study of country image and reputation, namely international relations theory and nation branding.. Analyzed are also the most topical disagreements about the "soft power" in the discourse of world politics.

  5. Nuclear Plant Analyzer development at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Laats, E.T.; Beelman, R.J.; Charlton, T.R.; Hampton, N.L.; Burtt, J.D.

    1985-01-01

    The Nuclear Plant Analyzer (NPA) is a state-of-the-art safety analysis and engineering tool being used to address key nuclear power plant safety issues. The NPA has been developed to integrate the NRC's computerized reactor behavior simulation codes such as RELAP5, TRAC-BWR, and TRAC-PWR, with well-developed computer graphics programs and large repositories of reactor design and experimental data. An important feature of the NAP is the capability to allow an analyst to redirect a RELAP5 or TRAC calculation as it progresses through its simulated scenario. The analyst can have the same power plant control capabilities as the operator of an actual plant. The NPA resides on the dual CDS Cyber-176 mainframe computers at the INEL and is being converted to operate on a Cray-1S computer at the LANL. The subject of this paper is the program conducted at the INEL

  6. Dynamic Frequency Response of Wind Power Plants

    DEFF Research Database (Denmark)

    Altin, Müfit

    according to their grid codes. In these scenarios particularly with high wind power penetration cases, conventional power plants (CPPs) such as old thermal power plants are planned to be replaced with wind power plants (WPPs). Consequently, the power system stability will be affected and the control...... to maintain sustainable and reliable operation of the power system for these targets, transmission system operators (TSOs) have revised the grid code requirements. Also, the TSOs are planning the future development of the power system with various wind penetration scenarios to integrate more wind power...... capability of WPPs would be investigated. The objective of this project is to analyze and identify the power system requirements for the synchronizing power support and inertial response control of WPPs in high wind power penetration scenarios. The dynamic frequency response of WPPs is realized...

  7. Programmable calculator: alternative to minicomputer-based analyzer

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1979-01-01

    Described are a number of typical field and laboratory counting systems that use standard stand-alone multichannel analyzers (MCA) interfaced to a Hewlett-Packard Company (HP 9830) programmable calculator. Such systems can offer significant advantages in cost and flexibility over a minicomputyr-based system. Because most laboratories tend to accumulate MCA's over the years, the programmable calculator also offers an easy way to upgrade the laboratory while making optimum use of existing systems. Software programs are easily tailored to fit a variety of general or specific applications. The only disadvantage of the calculator vs a computer-based system is in speed of analyses; however, for most applications this handicap is minimal. Applications discussed give a brief overview of the power and flexibility of the MCA-calculator approach to automated counting and data reduction

  8. Toroidal silicon polarization analyzer for resonant inelastic x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Xuan [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States); Key Laboratory of Multi-scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714 (China); Casa, Diego; Kim, Jungho; Gog, Thomas [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Li, Chengyang [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States); Department of Physics, South University of Science and Technology of China, Shenzhen 518055 (China); Burns, Clement [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States)

    2016-08-15

    Resonant Inelastic X-ray Scattering (RIXS) is a powerful probe for studying electronic excitations in materials. Standard high energy RIXS measurements do not measure the polarization of the scattered x-rays, which is unfortunate since it carries information about the nature and symmetry of the excitations involved in the scattering process. Here we report the fabrication of thin Si-based polarization analyzers with a double-concave toroidal surface, useful for L-edge RIXS studies in heavier atoms such as the 5-d transition metals.

  9. Resonant High Power Combiners

    CERN Document Server

    Langlois, Michel; Peillex-Delphe, Guy

    2005-01-01

    Particle accelerators need radio frequency sources. Above 300 MHz, the amplifiers mostly used high power klystrons developed for this sole purpose. As for military equipment, users are drawn to buy "off the shelf" components rather than dedicated devices. IOTs have replaced most klystrons in TV transmitters and find their way in particle accelerators. They are less bulky, easier to replace, more efficient at reduced power. They are also far less powerful. What is the benefit of very compact sources if huge 3 dB couplers are needed to combine the power? To alleviate this drawback, we investigated a resonant combiner, operating in TM010 mode, able to combine 3 to 5 IOTs. Our IOTs being able to deliver 80 kW C.W. apiece, combined power would reach 400 kW minus the minor insertion loss. Values for matching and insertion loss are given. The behavior of the system in case of IOT failure is analyzed.

  10. A Method for Analyzing the Communications among Nuclear Power Plant Operators in Emergency Situations

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Park, Jin Kyun; Jung, Won Dea

    2006-01-01

    Communications among MCR operators is an important factor for understanding how and how well MCR operators manage abnormal situations in NPPs. As mentioned by Ujita et al., the performance of MCR operators in emergency situations in NPPs is strongly affected by not only the cognitive process for each operator, but also by communications and collaboration among operators. Many researches have been conducted to find out the relation between the communication of human operators and the performance of them. But, it seems that few researches have been conducted on in what way the communication among MCR operators should be performed to enhance the performance of them. In this paper, we propose an analysis method for evaluating the quality of communications among MCR operators in nuclear power plants (NPPs)

  11. Determination of the analyzing power of the A4 Compton-backscattering polarimeter for the measurement of the longitudinal spin polarization of the MAMI electron beam

    International Nuclear Information System (INIS)

    Diefenbacher, Juergen

    2010-01-01

    The A4 experiment determines the strange quark contribution to the electromagnetic from factors of the nucleon by measuring the parity violation in elastic electron nucleon scattering. These measurements are carried out using the spin polarized electron beam of the Mainzer Mikrotron (MAMI) with beam energies in the range from 315 to 1508 MeV. For the data analysis it is essential to determine the degree of polarization of the electron beam in order to extract the physics asymmetry from the measured parity violating asymmetry. For this reason the A4 collaboration has developed a novel type of Compton laser backscattering polarimeter that allows for a non-destructive measurement of the beam polarization in parallel to the running parity experiment. In the scope of this work the polarimeter was refined in order to enable reliable continuous operation of the polarimeter. The data acquisition system for the photon and electron detector was re-designed and optimized to cope with high count rates. A novel detector (LYSO) for the backscattered photons was commissioned. Furthermore, GEANT4 simulations of the detectors have been performed and an analysis environment for the extraction of Compton asymmetries from the backscattered photon data has been developed. The analysis makes use of the possibility to detect backscattered photons in coincidence with the scattered electrons, thus tagging the photons. The tagging introduces a differential energy scale which enables the precise determination of the analyzing power. In this work the analyzing power of the polarimeter has been determined. Therefore, at a beam current of 20 μA the product of electron and laser polarization can be determined, while the parity experiment is running, with a statistical accuracy of 1 % in 24 hours at 855 MeV or 2 =0.6 (GeV/c) 2 the analysis yields a raw asymmetry of A Roh PV =(-20.0±0.9 stat ) x 10 -6 at the moment. For a beam polarization of 80 % the total error would be 1,68 x 10 -6 with ΔP e

  12. Small nuclear power reactor emergency electric power supply system reliability comparative analysis

    International Nuclear Information System (INIS)

    Bonfietti, Gerson

    2003-01-01

    This work presents an analysis of the reliability of the emergency power supply system, of a small size nuclear power reactor. Three different configurations are investigated and their reliability analyzed. The fault tree method is used as the main tool of analysis. The work includes a bibliographic review of emergency diesel generator reliability and a discussion of the design requirements applicable to emergency electrical systems. The influence of common cause failure influences is considered using the beta factor model. The operator action is considered using human failure probabilities. A parametric analysis shows the strong dependence between the reactor safety and the loss of offsite electric power supply. It is also shown that common cause failures can be a major contributor to the system reliability. (author)

  13. Optimal Control of Wind Power Generation

    Directory of Open Access Journals (Sweden)

    Pawel Pijarski

    2018-03-01

    Full Text Available Power system control is a complex task, which is strongly related to the number and kind of generating units as well as to the applied technologies, such as conventional coal fired power plants or wind and photovoltaic farms. Fast development of wind generation that is considered as unstable generation sets new strong requirements concerning remote control and data hubs cooperating with SCADA systems. Considering specific nature of the wind power generation, the authors analyze the problem of optimal control for wind power generation in farms located over a selected remote-controlled part of the Operator grid under advantageous wind conditions. This article presents an original stepwise method for tracing power flows that makes possible to eliminate current (power overloading of power grid branches. Its core idea is to consider the discussed problem as an optimization task.

  14. Development of the MARS input model for Ulchin 3/4 transient analyzer

    International Nuclear Information System (INIS)

    Jeong, J. J.; Kim, K. D.; Lee, S. W.; Lee, Y. J.; Lee, W. J.; Chung, B. D.; Hwang, M. G.

    2003-12-01

    KAERI has been developing the NSSS transient analyzer based on best-estimate codes.The MARS and RETRAN code are adopted as the best-estimate codes for the NSSS transient analyzer. Among these two codes, the MARS code is to be used for realistic analysis of small- and large-break loss-of-coolant accidents, of which break size is greater than 2 inch diameter. This report includes the MARS input model requirements and the calculation note for the MARS input data generation (see the Appendix) for Ulchin 3/4 plant analyzer. In order to confirm the validity of the input data, we performed the calculations for a steady state at 100 % power operation condition and a double-ended cold leg break LOCA. The results of the steady-state calculation agree well with the design data. The results of the LOCA calculation seem to be reasonable and consistent with those of other best-estimate calculations. Therefore, the MARS input data can be used as a base input deck for the MARS transient analyzer for Ulchin 3/4

  15. Electron attachment analyzer

    International Nuclear Information System (INIS)

    Popp, P.; Grosse, H.J.; Leonhardt, J.; Mothes, S.; Oppermann, G.

    1984-01-01

    The invention concerns an electron attachment analyzer for detecting traces of electroaffine substances in electronegative gases, especially in air. The analyzer can be used for monitoring working places, e. g., in operating theatres. The analyzer consists of two electrodes inserted in a base frame of insulating material (quartz or ceramics) and a high-temperature resistant radiation source ( 85 Kr, 3 H, or 63 Ni)

  16. Role and position of Nuclear Power Plants Research Institute in nuclear power industry

    International Nuclear Information System (INIS)

    Metke, E.

    1984-01-01

    The Nuclear Power Plants Research Institute carries out applied and experimental research of the operating states of nuclear power plants, of new methods of surveillance and diagnosis of technical equipment, it prepares training of personnel, carries out tests, engineering and technical consultancy and the research of automated control systems. The main research programme of the Institute is the rationalization of raising the safety and operating reliability of WWER nuclear power plants. The Institute is also concerned with quality assurance of selected equipment of nuclear power plants and assembly works, with radioactive waste disposal and the decommissioning of nuclear power plants as well as with the preparation and implementation of the nuclear power plant start-up. The Research Institute is developing various types of equipment, such as equipment for the decontamination of the primary part of the steam generator, a continuous analyzer of chloride levels in water, a gas monitoring instrument, etc. The prospects are listed of the Research Institute and its cooperation with other CMEA member countries. (M.D.)

  17. A high energy hemispherical analyzer for experimental station of PES beamline at Indus-2

    International Nuclear Information System (INIS)

    Jagannath; Sharma, R.K.; Goutam, U.K.; Mithal, N.; Sule, U.S.; Gadkari, S.C.; Yakhmi, J.V.; Sahni, V.C.

    2009-03-01

    This article describes the design and development of Hemispherical Deflector Analyzer that is especially designed to analyze high kinetic energy electrons (up to 15 keV) with an energy resolution (ΔE/E) of the order of ∼10 -4 for experimental station of PES beamline (BL-14) on Indus-2, a third generation synchrotron source at RRCAT, Indore. With such a high KE analyzing capacity, this analyzer facilitates to measure bulk electronic properties of solids by the Photoemission Spectroscopy with Synchrotron Radiation preserving an energy resolution comparable to modern surface sensitive photoemission spectra. In order to attain better energy resolution over a wider kinetic energy range of electrons, we have designed and constructed a dedicated input lens system for the analyzer. It is further connected with a high stability power supplies, a low dark-count delay line detector and read-out electronics. The system has been designed and fabrication work is almost complete for testing. (author)

  18. Analyzing petabytes of data with Hadoop

    CERN Multimedia

    CERN. Geneva

    2009-01-01

    Abstract The open source Apache Hadoop project provides a powerful suite of tools for storing and analyzing petabytes of data using commodity hardware. After several years of production use inside of web companies like Yahoo! and Facebook and nearly a year of commercial support and development by Cloudera, the technology is spreading rapidly through other disciplines, from financial services and government to life sciences and high energy physics. The talk will motivate the design of Hadoop and discuss some key implementation details in depth. It will also cover the major subprojects in the Hadoop ecosystem, go over some example applications, highlight best practices for deploying Hadoop in your environment, discuss plans for the future of the technology, and provide pointers to the many resources available for learning more. In addition to providing more information about the Hadoop platform, a major goal of this talk is to begin a dialogue with the ATLAS research team on how the tools commonly used in t...

  19. Control Architecture for Future Power Systems

    DEFF Research Database (Denmark)

    Heussen, Kai

    for assessment of control architecture of electric power systems with a means-ends perspective. Given this purpose-oriented understanding of a power system, the increasingly stochastic nature of this problem shall be addressed and approaches for robust, distributed control will be proposed and analyzed....... The introduction of close-to-real-time markets is envisioned to enable fast distributed resource allocation while guaranteeing system stability. Electric vehicles will be studied as a means of distributed reversible energy storage and a flexible power electronic interface, with application to the case......This project looks at control of future electric power grids with a high proportion of wind power and a large number of decentralized power generation, consumption and storage units participating to form a reliable supply of electrical energy. The first objective is developing a method...

  20. POLITICAL PSYCHOLOGY – NEW CHALLENGES IN ANALYZING FOREIGN POLICY

    Directory of Open Access Journals (Sweden)

    Karin MEGHEȘAN

    2016-06-01

    Full Text Available The art of governance, the relationship between the governed and the governing, the impact of a social and political system on coherent foreign policy-building is significantly influenced by the distribution of power and the type of decisional unit existent within the state. New subjects of study, such as political psychology, have proved their utility both in theoretical and practical study of international relations. Being a frontier subject, political psychology tries to offer answers to a number of questions regarding different issues among which the way character features influence the decision maker’s behavior, the role of the operational code in foreign policy and the utility of psychological profiles in the international relationships and in intelligence. Leading from the types of power distribution and decisional units existent in the professional literature, the present paper narrows the narrative and focuses on examining the importance of the individual level of analysis in explaining foreign policy decisions, analyzing the decision of the Russian Federation to veto the intervention of the international community in the Syrian civil conflict.

  1. Maximum generation power evaluation of variable frequency offshore wind farms when connected to a single power converter

    Energy Technology Data Exchange (ETDEWEB)

    Gomis-Bellmunt, Oriol; Sumper, Andreas [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2, 08028 Barcelona (Spain); IREC Catalonia Institute for Energy Research, Barcelona (Spain); Junyent-Ferre, Adria; Galceran-Arellano, Samuel [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2, 08028 Barcelona (Spain)

    2010-10-15

    The paper deals with the evaluation of power generated by variable and constant frequency offshore wind farms connected to a single large power converter. A methodology to analyze different wind speed scenarios and system electrical frequencies is presented and applied to a case study, where it is shown that the variable frequency wind farm concept (VF) with a single power converter obtains 92% of the total available power, obtained with individual power converters in each wind turbine (PC). The PC scheme needs multiple power converters implying drawbacks in terms of cost, maintenance and reliability. The VF scheme is also compared to a constant frequency scheme CF, and it is shown that a significant power increase of more than 20% can be obtained with VF. The case study considers a wind farm composed of four wind turbines based on synchronous generators. (author)

  2. Power and the Role of the Superintendent

    Science.gov (United States)

    Miller, Teresa Northern; Salsberry, Trudy A.; Devin, Mary A.

    2009-01-01

    This study of the superintendent focus group interviews from the "Voices 3" project adds to the research base with regard to the range and nature of the types of power experienced or used by superintendents. Using the French & Raven/Andrews & Baird model of seven types of power, the authors analyzed superintendents'…

  3. Analysis of effect of safety classification on DCS design in nuclear power plants

    International Nuclear Information System (INIS)

    Gou Guokai; Li Guomin; Wang Qunfeng

    2011-01-01

    By analyzing the safety classification for the systems and functions of nuclear power plants based on the general design requirements for nuclear power plants, especially the requirement of availability and reliability of I and C systems, the characteristics of modem DCS technology and I and C products currently applied in nuclear power field are interpreted. According to the requirements on the safety operation of nuclear power plants and the regulations for safety audit, the effect of different safety classifications on DCS design in nuclear power plants is analyzed, by considering the actual design process of different DCS solutions in the nuclear power plants under construction. (authors)

  4. Analysis of Power System Low Frequency Oscillation Based on Energy Shift Theory

    Science.gov (United States)

    Zhang, Junfeng; Zhang, Chunwang; Ma, Daqing

    2018-01-01

    In this paper, a new method for analyzing low-frequency oscillation between analytic areas based on energy coefficient is proposed. The concept of energy coefficient is proposed by constructing the energy function, and the low-frequency oscillation is analyzed according to the energy coefficient under the current operating conditions; meanwhile, the concept of model energy is proposed to analyze the energy exchange behavior between two generators. Not only does this method provide an explanation of low-frequency oscillation from the energy point of view, but also it helps further reveal the dynamic behavior of complex power systems. The case analysis of four-machine two-area and the power system of Jilin Power Grid proves the correctness and effectiveness of the proposed method in low-frequency oscillation analysis of power system.

  5. Adaptive Neural Network Algorithm for Power Control in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Husam Fayiz, Al Masri

    2017-01-01

    The aim of this paper is to design, test and evaluate a prototype of an adaptive neural network algorithm for the power controlling system of a nuclear power plant. The task of power control in nuclear reactors is one of the fundamental tasks in this field. Therefore, researches are constantly conducted to ameliorate the power reactor control process. Currently, in the Department of Automation in the National Research Nuclear University (NRNU) MEPhI, numerous studies are utilizing various methodologies of artificial intelligence (expert systems, neural networks, fuzzy systems and genetic algorithms) to enhance the performance, safety, efficiency and reliability of nuclear power plants. In particular, a study of an adaptive artificial intelligent power regulator in the control systems of nuclear power reactors is being undertaken to enhance performance and to minimize the output error of the Automatic Power Controller (APC) on the grounds of a multifunctional computer analyzer (simulator) of the Water-Water Energetic Reactor known as Vodo-Vodyanoi Energetichesky Reaktor (VVER) in Russian. In this paper, a block diagram of an adaptive reactor power controller was built on the basis of an intelligent control algorithm. When implementing intelligent neural network principles, it is possible to improve the quality and dynamic of any control system in accordance with the principles of adaptive control. It is common knowledge that an adaptive control system permits adjusting the controller’s parameters according to the transitions in the characteristics of the control object or external disturbances. In this project, it is demonstrated that the propitious options for an automatic power controller in nuclear power plants is a control system constructed on intelligent neural network algorithms. (paper)

  6. 76 FR 81998 - Methodology for Low Power/Shutdown Fire PRA

    Science.gov (United States)

    2011-12-29

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0295] Methodology for Low Power/Shutdown Fire PRA AGENCY..., ``Methodology for Low Power/Shutdown Fire PRA--Draft Report for Comment.'' DATES: Submit comments by March 01... risk assessment (PRA) method for quantitatively analyzing fire risk in commercial nuclear power plants...

  7. Market power analysis for the Iranian electricity market

    International Nuclear Information System (INIS)

    Asgari, Mohammad Hossein; Monsef, Hassan

    2010-01-01

    The market power problem in Iranian electricity market is addressed in this study. This paper by using various structural indices of market power and reviewing market results analyzes the intensity of competition in Iran's electricity market and examines whether this market is functioning at an appropriate level of efficiency. In this article the most well-known indices of market power are calculated in two approaches for two different scenarios (current situation and future outlook of generation sector's ownership in Iran's power industry). Comparing the results of these scenarios promises more competitive market for the second scenario. Calculating Residual Supply Index for Iran's power market shows despite admissible values of concentration ratios, due to supply scarcity during periods when the demand is close to the total available capacity, some suppliers can exercise market power even with a relatively small market share. The most important price and load indices like weighted average prices and load/price duration curves of Iranian electricity market during March 2007-March 2008 are also analyzed in this paper. These results imply the existence of economic withholding. The main limiting factors of competition and significant implemented countermeasures for market power mitigation in Iran's electricity market are also mentioned.

  8. Reactive power influence on the thermal cycling of multi-MW wind power inverter

    DEFF Research Database (Denmark)

    Ma, Ke; Liserre, Marco; Blaabjerg, Frede

    2012-01-01

    converter system are first presented at different wind speeds. Furthermore, the interaction between paralleled converter systems in a wind park is also considered and analyzed. By controlling the reactive power circulated among paralleled converters, a new concept is then proposed to stabilize the thermal...

  9. Output power maximization of low-power wind energy conversion systems revisited: Possible control solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vlad, Ciprian; Munteanu, Iulian; Bratcu, Antoneta Iuliana; Ceanga, Emil [' ' Dunarea de Jos' ' University of Galati, 47, Domneasca, 800008-Galati (Romania)

    2010-02-15

    This paper discusses the problem of output power maximization for low-power wind energy conversion systems operated in partial load. These systems are generally based on multi-polar permanent-magnet synchronous generators, who exhibit significant efficiency variations over the operating range. Unlike the high-power systems, whose mechanical-to-electrical conversion efficiency is high and practically does not modify the global optimum, the low-power systems global conversion efficiency is affected by the generator behavior and the electrical power optimization is no longer equivalent with the mechanical power optimization. The system efficiency has been analyzed by using both the maxima locus of the mechanical power versus the rotational speed characteristics, and the maxima locus of the electrical power delivered versus the rotational speed characteristics. The experimental investigation has been carried out by using a torque-controlled generator taken from a real-world wind turbine coupled to a physically simulated wind turbine rotor. The experimental results indeed show that the steady-state performance of the conversion system is strongly determined by the generator behavior. Some control solutions aiming at maximizing the energy efficiency are envisaged and thoroughly compared through experimental results. (author)

  10. Output power maximization of low-power wind energy conversion systems revisited: Possible control solutions

    International Nuclear Information System (INIS)

    Vlad, Ciprian; Munteanu, Iulian; Bratcu, Antoneta Iuliana; Ceanga, Emil

    2010-01-01

    This paper discusses the problem of output power maximization for low-power wind energy conversion systems operated in partial load. These systems are generally based on multi-polar permanent-magnet synchronous generators, who exhibit significant efficiency variations over the operating range. Unlike the high-power systems, whose mechanical-to-electrical conversion efficiency is high and practically does not modify the global optimum, the low-power systems global conversion efficiency is affected by the generator behavior and the electrical power optimization is no longer equivalent with the mechanical power optimization. The system efficiency has been analyzed by using both the maxima locus of the mechanical power versus the rotational speed characteristics, and the maxima locus of the electrical power delivered versus the rotational speed characteristics. The experimental investigation has been carried out by using a torque-controlled generator taken from a real-world wind turbine coupled to a physically simulated wind turbine rotor. The experimental results indeed show that the steady-state performance of the conversion system is strongly determined by the generator behavior. Some control solutions aiming at maximizing the energy efficiency are envisaged and thoroughly compared through experimental results.

  11. Nuclear Plant Analyzer development at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Laats, E.T.

    1986-10-01

    The Nuclear Plant Analyzer (NPA) is a state-of-the-art safety analysis and engineering tool being used to address key nuclear power plant safety issues. Under the sponsorship of the US Nuclear Regulatory Commission (NRC), the NPA has been developed to integrate the NRC's computerized reactor behavior simulation codes such as RELAP5, TRAC-BWR and TRAC-PWR, with well-developed computer color graphics programs and large repositories of reactor design and experimental data. An important feature of the NPA is the capability to allow an analyst to redirect a RELAP5 or TRAC calculation as it progresses through its simulated scenario. The analyst can have the same power plant control capabilities as the operator of an actual plant. The NPA resides on the dual Control Data Corporation Cyber 176 mainframe computers at the Idaho National Engineering Laboratory and Cray-1S computers at the Los Alamos National Laboratory (LANL) and Kirtland Air Force Weapons Laboratory (KAFWL)

  12. Adaptation of thermal power plants: The (ir)relevance of climate (change) information

    International Nuclear Information System (INIS)

    Bogmans, Christian W.J.; Dijkema, Gerard P.J.; Vliet, Michelle T.H. van

    2017-01-01

    When does climate change information lead to adaptation? We analyze thermal power plant adaptation by means of investing in water-saving (cooling) technology to prevent a decrease in plant efficiency and load reduction. A comprehensive power plant investment model, forced with downscaled climate and hydrological projections, is then numerically solved to analyze the adaptation decisions of a selection of real power plants. We find that operators that base their decisions on current climatic conditions are likely to make identical choices and perform just as well as operators that are fully ‘informed’ about climate change. Where electricity supply is mainly generated by thermal power plants, heat waves, droughts and low river flow may impact electricity supply for decades to come. - Highlights: • We analyze adaptation to climate change by thermal power plants. • A numerical investment model is applied to a coal plant and a nuclear power plant. • The numerical analysis is based on climate and hydrological projections. • Climate change information has a relatively small effect on a power plant's NPV. • Uncertainty and no-regret benefits lower the value of climate change information.

  13. Analysis of economy characteristics and improvement ways for China nuclear power

    International Nuclear Information System (INIS)

    Li Yong

    2010-01-01

    For the nuclear power industry, due to characteristics of its own, its economy is quite different from that of the traditional fossil-fuel power. This paper studied the basic characteristics of the nuclear power economy and the status of economy of domestic nuclear power, and analyzed the main ways to improve the nuclear power economy. (authors)

  14. A low-cost multichannel pulse-height analyzer PHA 256 using single-chip microcomputer

    International Nuclear Information System (INIS)

    Koehler, M.; Meiling, W.

    1985-01-01

    The PHA 256 multichannel analyzer on the base of the U8820 single-chip microcomputer applied for radiation measurements, for example in monitoring systems with scintillation detectors, is described. The analyzer contains a power supply unit and 7 boards, namely, the processor board; data and program memory; 8-bit analog-to-digital converter; driver to display device; keyboard with 23 function keys; pulse amplifier and high-voltage supply (up to 2 kV). Software used provides preprocessing of spectra supported by following functions: addition and subtraction of different spectra, spectrum monitoring by use of a 5-point-algorithm, calculation of peak areas with linearly interpolated background

  15. Towards a New Framework for Soft Power: An Observation of China’s Confucius Institute

    OpenAIRE

    LEE, Kyoungtaek

    2010-01-01

    There are many controversial and differing opinions concerning Nye’s concept of soft power which have lead to some confusion in our understanding of what soft power actually is. By analyzing a given governmental agency, i.e. China’s Confucius Institute, I will show the problem inherent in Nye’s term soft power. I will analyze the concept of soft power as a combination of two meanings: ‘soft’ and ‘power’. I believe this research could offer a new perspective on the concept of soft power and co...

  16. Wind Power Potential at Abandoned Mines in Korea

    Science.gov (United States)

    jang, M.; Choi, Y.; Park, H.; Go, W.

    2013-12-01

    This study performed an assessment of wind power potential at abandoned mines in the Kangwon province by analyzing gross energy production, greenhouse gas emission reduction and economic effects estimated from a 600 kW wind turbine. Wind resources maps collected from the renewable energy data center in Korea Institute of Energy Research(KIER) were used to determine the average wind speed, temperature and atmospheric pressure at hub height(50 m) for each abandoned mine. RETScreen software developed by Natural Resources Canada(NRC) was utilized for the energy, emission and financial analyses of wind power systems. Based on the results from 5 representative mining sites, we could know that the average wind speed at hub height is the most critical factor for assessing the wind power potential. Finally, 47 abandoned mines that have the average wind speed faster than 6.5 m/s were analyzed, and top 10 mines were suggested as relatively favorable sites with high wind power potential in the Kangwon province.

  17. General Forced Oscillations in a Real Power Grid Integrated with Large Scale Wind Power

    Directory of Open Access Journals (Sweden)

    Ping Ju

    2016-07-01

    Full Text Available According to the monitoring of the wide area measurement system, inter-area oscillations happen more and more frequently in a real power grid of China, which are close to the forced oscillation. Applying the conventional forced oscillation theory, the mechanism of these oscillations cannot be explained well, because the oscillations vary with random amplitude and a narrow frequency band. To explain the mechanism of such oscillations, the general forced oscillation (GFO mechanism is taken into consideration. The GFO is the power system oscillation excited by the random excitations, such as power fluctuations from renewable power generation. Firstly, properties of the oscillations observed in the real power grid are analyzed. Using the GFO mechanism, the observed oscillations seem to be the GFO caused by some random excitation. Then the variation of the wind power measured in this power gird is found to be the random excitation which may cause the GFO phenomenon. Finally, simulations are carried out and the power spectral density of the simulated oscillation is compared to that of the observed oscillation, and they are similar with each other. The observed oscillation is thus explained well using the GFO mechanism and the GFO phenomenon has now been observed for the first time in real power grids.

  18. Power-up: A Reanalysis of 'Power Failure' in Neuroscience Using Mixture Modeling.

    Science.gov (United States)

    Nord, Camilla L; Valton, Vincent; Wood, John; Roiser, Jonathan P

    2017-08-23

    Recently, evidence for endemically low statistical power has cast neuroscience findings into doubt. If low statistical power plagues neuroscience, then this reduces confidence in the reported effects. However, if statistical power is not uniformly low, then such blanket mistrust might not be warranted. Here, we provide a different perspective on this issue, analyzing data from an influential study reporting a median power of 21% across 49 meta-analyses (Button et al., 2013). We demonstrate, using Gaussian mixture modeling, that the sample of 730 studies included in that analysis comprises several subcomponents so the use of a single summary statistic is insufficient to characterize the nature of the distribution. We find that statistical power is extremely low for studies included in meta-analyses that reported a null result and that it varies substantially across subfields of neuroscience, with particularly low power in candidate gene association studies. Therefore, whereas power in neuroscience remains a critical issue, the notion that studies are systematically underpowered is not the full story: low power is far from a universal problem. SIGNIFICANCE STATEMENT Recently, researchers across the biomedical and psychological sciences have become concerned with the reliability of results. One marker for reliability is statistical power: the probability of finding a statistically significant result given that the effect exists. Previous evidence suggests that statistical power is low across the field of neuroscience. Our results present a more comprehensive picture of statistical power in neuroscience: on average, studies are indeed underpowered-some very seriously so-but many studies show acceptable or even exemplary statistical power. We show that this heterogeneity in statistical power is common across most subfields in neuroscience. This new, more nuanced picture of statistical power in neuroscience could affect not only scientific understanding, but potentially

  19. Equivalent modeling of PMSG-based wind power plants considering LVRT capabilities: electromechanical transients in power systems.

    Science.gov (United States)

    Ding, Ming; Zhu, Qianlong

    2016-01-01

    Hardware protection and control action are two kinds of low voltage ride-through technical proposals widely used in a permanent magnet synchronous generator (PMSG). This paper proposes an innovative clustering concept for the equivalent modeling of a PMSG-based wind power plant (WPP), in which the impacts of both the chopper protection and the coordinated control of active and reactive powers are taken into account. First, the post-fault DC link voltage is selected as a concentrated expression of unit parameters, incoming wind and electrical distance to a fault point to reflect the transient characteristics of PMSGs. Next, we provide an effective method for calculating the post-fault DC link voltage based on the pre-fault wind energy and the terminal voltage dip. Third, PMSGs are divided into groups by analyzing the calculated DC link voltages without any clustering algorithm. Finally, PMSGs of the same group are equivalent as one rescaled PMSG to realize the transient equivalent modeling of the PMSG-based WPP. Using the DIgSILENT PowerFactory simulation platform, the efficiency and accuracy of the proposed equivalent model are tested against the traditional equivalent WPP and the detailed WPP. The simulation results show the proposed equivalent model can be used to analyze the offline electromechanical transients in power systems.

  20. Fault analysis and strategy of high pulsed power supply for high power laser

    International Nuclear Information System (INIS)

    Liu Kefu; Qin Shihong; Li Jin; Pan Yuan; Yao Zonggan; Zheng Wanguo; Guo Liangfu; Zhou Peizhang; Li Yizheng; Chen Dehuai

    2001-01-01

    according to the requirements of driving flash-lamp, a high pulsed power supply (PPS) based on capacitors as energy storage elements is designed. The author analyzes in detail the faults of high pulsed power supply for high power laser. Such as capacitor internal short-circuit, main bus breakdown to ground, flashlamp sudden short or break. The fault current and voltage waveforms were given by circuit simulations. Based on the analysis and computation, the protection strategy with the fast fuse and ZnO was put forward, which can reduce the damage of PPS to the lower extent and provide the personnel safe and collateral property from the all threats. The preliminary experiments demonstrated that the design of the PPS can satisfy the project requirements

  1. Impact of the Voltage Dips in Shipboard Microgrid Power Systems

    DEFF Research Database (Denmark)

    Liu, Wenzhao; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    Voltage and frequency transient variations are the most common power quality issues in a ship microgrid system. In this paper, the impacts of the voltage dips induced by the sudden-load of ballast pump are analyzed in detail for the ship power systems. Several relevant ship power quality standards...

  2. Impact of network topology on synchrony of oscillatory power grids

    Energy Technology Data Exchange (ETDEWEB)

    Rohden, Martin; Sorge, Andreas; Witthaut, Dirk [Network Dynamics, Max Planck Institute for Dynamics and Self-Organization (MPIDS), 37077 Göttingen (Germany); Timme, Marc [Network Dynamics, Max Planck Institute for Dynamics and Self-Organization (MPIDS), 37077 Göttingen (Germany); Faculty of Physics, Georg August Universität Göttingen, Göttingen (Germany)

    2014-03-15

    Replacing conventional power sources by renewable sources in current power grids drastically alters their structure and functionality. In particular, power generation in the resulting grid will be far more decentralized, with a distinctly different topology. Here, we analyze the impact of grid topologies on spontaneous synchronization, considering regular, random, and small-world topologies and focusing on the influence of decentralization. We model the consumers and sources of the power grid as second order oscillators. First, we analyze the global dynamics of the simplest non-trivial (two-node) network that exhibit a synchronous (normal operation) state, a limit cycle (power outage), and coexistence of both. Second, we estimate stability thresholds for the collective dynamics of small network motifs, in particular, star-like networks and regular grid motifs. For larger networks, we numerically investigate decentralization scenarios finding that decentralization itself may support power grids in exhibiting a stable state for lower transmission line capacities. Decentralization may thus be beneficial for power grids, regardless of the details of their resulting topology. Regular grids show a specific sharper transition not found for random or small-world grids.

  3. Crossed, Small-Deflection Energy Analyzer for Wind/Temperature Spectrometer

    Science.gov (United States)

    Herrero, Federico A.; Finne, Theodore T.

    2010-01-01

    Determination of neutral winds and ion drifts in low-Earth-orbit missions requires measurements of the angular and energy distributions of the flux of neutrals and ions entering the satellite from the ram direction. The magnitude and direction of the neutral-wind (or ion-drift) determine the location of the maximum in the angular distribution of the flux. Knowledge of the angle of maximum flux with respect to satellite coordinates (pointing) is essential to determine the wind (or ion-drift) vector. The crossed Small-Deflection Energy Analyzer (SDEA) spectrometer (see Figure 1) occupies minimal volume and consumes minimal power. Designed for upper atmosphere/ionosphere investigations at Earth altitudes above 100 km, the spectrometer operates by detecting the angular and energy distributions of neutral atoms/molecules and ions in two mutually perpendicular planes. In this configuration, the two detection planes actually cross at the spectrometer center. It is possible to merge two SDEAs so they share a common optical axis and alternate measurements between two perpendicular planes, and reduce the number of ion sources from two to one. This minimizes the volume and footprint significantly and reduces the ion source power by a factor of two. The area of the entrance aperture affects the number of ions detected/second and also determines the energy resolution. Thermionic emitters require heater power of about 100 mW to produce 1 mA of electron beam current. Typically, electron energy is about 100 eV and requires a 100-V supply for electron acceleration to supply an additional 100 mW of power. Thus, ion source power is at most 200 mW. If two ion sources were to be used, the ion source power would be, at most, 400 mW. Detector power, deflection voltage power, and microcontroller and other functions require less than 150 mW. A WTS (wind/ temperature spectrometer) with two separate optical axes would consume about 650 mW, while the crossed SDEA described here consumes about

  4. Measurement of power loss during electric vehicle charging and discharging

    International Nuclear Information System (INIS)

    Apostolaki-Iosifidou, Elpiniki; Codani, Paul; Kempton, Willett

    2017-01-01

    When charging or discharging electric vehicles, power losses occur in the vehicle and the building systems supplying the vehicle. A new use case for electric vehicles, grid services, has recently begun commercial operation. Vehicles capable of such application, called Grid-Integrated Vehicles, may have use cases with charging and discharging summing up to much more energy transfer than the charging only use case, so measuring and reducing electrical losses is even more important. In this study, the authors experimentally measure and analyze the power losses of a Grid-Integrated Vehicle system, via detailed measurement of the building circuits, power feed components, and of sample electric vehicle components. Under the conditions studied, measured total one-way losses vary from 12% to 36%, so understanding loss factors is important to efficient design and use. Predominant losses occur in the power electronics used for AC-DC conversion. The electronics efficiency is lowest at low power transfer and low state-of-charge, and is lower during discharging than charging. Based on these findings, two engineering design approaches are proposed. First, optimal sizing of charging stations is analyzed. Second, a dispatch algorithm for grid services operating at highest efficiency is developed, showing 7.0% to 9.7% less losses than the simple equal dispatch algorithm. - Highlights: • Grid-to-battery-to-grid comprehensive power loss measurement and analysis. • No previous experimental measurements of Grid-Integrated Vehicle system power loss. • Electric vehicle loss analyzed as a factor of state of charge and charging rate. • Power loss in the building components less than 3%. • Largest losses found in Power Electronics (typical round-trip loss 20%).

  5. A 380 V High Efficiency and High Power Density Switched-Capacitor Power Converter using Wide Band Gap Semiconductors

    DEFF Research Database (Denmark)

    Fan, Lin; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2018-01-01

    . This paper presents such a high voltage low power switched-capacitor DC-DC converter with an input voltage upto 380 V (compatible with rectified European mains) and an output power experimentally validated up to 21.3 W. The wideband gap semiconductor devices of GaN switches and SiC diodes are combined...... to compose the proposed power stage. Their switching and loss characteristics are analyzed with transient waveforms and thermal images. Different isolated driving circuits are compared and a compact isolated halfbridge driving circuit is proposed. The full-load efficiencies of 98.3% and 97.6% are achieved......State-of-the-art switched-capacitor DC-DC power converters mainly focus on low voltage and/or high power applications. However, at high voltage and low power levels, new designs are anticipated to emerge and a power converter that has both high efficiency and high power density is highly desirable...

  6. Core power capability verification for PWR NPP

    International Nuclear Information System (INIS)

    Xian Chunyu; Liu Changwen; Zhang Hong; Liang Wei

    2002-01-01

    The Principle and methodology of pressurized water reactor nuclear power plant core power capability verification for reload are introduced. The radial and axial power distributions of normal operation (category I or condition I) and abnormal operation (category II or condition II) are simulated by using neutronics calculation code. The linear power density margin and DNBR margin for both categories, which reflect core safety, are analyzed from the point view of reactor physics and T/H, and thus category I operating domain and category II protection set point are verified. Besides, the verification results of reference NPP are also given

  7. Low-Carbon Economic Dispatching for Power Grid Integrated with Carbon Capture Power Plants and Wind Power System

    Directory of Open Access Journals (Sweden)

    Sheng Siqing

    2015-01-01

    Full Text Available Carbon emission characteristics of all kinds of power units are analyzed against the background of the low carbon economy. This paper introduces carbon trading in the dispatching model, gives full consideration to the benefit or cost of carbon emission and introduces carbon emission in the dispatching model as a decision variable so as to achieve the unity of the economy and the environmental protection of the dispatching model. A low carbon economic dispatching model is established based on multiple objectives, such as the lowest thermal power generation cost, the lowest carbon trading cost and the lowest carbon capture power plant operation cost. Load equalization, output constraint of power unit, ramping constraint, spinning reserve constraint and carbon capture efficiency constraint should be taken into account in terms of constraint conditions. The model is solved by the particle swarm optimization based on dynamic exchange and density distance. The fact that the introduction of carbon trading can effectively reduce the level of carbon emission and increase the acceptance level of wind power is highlighted through the comparison of the results of three models’ computational examples. With the carbon trading mechanism, carbon capture power plants with new technologies are able to give full play to the advantage of reducing carbon emission and wind curtailment so as to promote the development of the energy conservation and emission reduction technology and reduce the total cost of the dispatching system.

  8. Power Electronics and Controls for Large Wind Turbines and Wind Farms

    DEFF Research Database (Denmark)

    Ma, Ke; Shipurkar, Udai; Ionel, Dan M.

    2017-01-01

    in order to reach and even exceed a power rating of 10 MW are discussed. The role of power electronics for improving the operation of WTs and ensuring compliance with power grid codes is analyzed with a view to produce fully controllable generation units suitable for a tight integration into the power grid...

  9. Power Consumption Based Android Malware Detection

    OpenAIRE

    Hongyu Yang; Ruiwen Tang

    2016-01-01

    In order to solve the problem that Android platform’s sand-box mechanism prevents security protection software from accessing effective information to detect malware, this paper proposes a malicious software detection method based on power consumption. Firstly, the mobile battery consumption status information was obtained, and the Gaussian mixture model (GMM) was built by using Mel frequency cepstral coefficients (MFCC). Then, the GMM was used to analyze power consumption; malicious software...

  10. Self-powered detectors with thulium emitter

    International Nuclear Information System (INIS)

    Haller, P.; Klar, E.

    1978-01-01

    In addition to fission chambers, prompt-indicating self-powered (SPN) detectors are used for measuring the neutron flux density in the core of power reactors. Although current SPN detectors with a cobalt emitter give satisfactora results, detectors with other emitter materials have been analyzed and tested. The author describes the properties and decay pattern of the nuclide thulium and presents the results of measurements made while testing thulium detectors. (orig.) [de

  11. Power generation, operation and control

    CERN Document Server

    Wood, Allen J; Sheblé, Gerald B

    2013-01-01

    Since publication of the second edition, there have been extensive changes in the algorithms, methods, and assumptions in energy management systems that analyze and control power generation. This edition is updated to acquaint electrical engineering students and professionals with current power generation systems. Algorithms and methods for solving integrated economic, network, and generating system analysis are provided. Also included are the state-of-the-art topics undergoing evolutionary change, including market simulation, multiple market analysis, multiple interchange contract analysis, c

  12. Harmonic Resonances in Wind Power Plants

    DEFF Research Database (Denmark)

    Fernandez, Francisco Daniel Freijedo; Chaudhary, Sanjay; Teodorescu, Remus

    2015-01-01

    This work reviews the state-of-the-art in the field of harmonic resonance problems in Wind Power Plants (WPPs). Firstly, a generic WPP is modeled according to the equivalent circuits of its passive and active components. Main focus is put on modeling active components, i.e. the ones based on power...... converters. Subsequently, pros and cons of frequency and time domain analysis methods are outlined. The next sections are devoted to mitigation methods implemented in the power electronics converters. From the wind turbine perspective, different techniques to enhance the robustness of the controller...... are analyzed. Subsequently, the suitability for active damping of harmonics using STATCOM devices is assessed, with focus both on control techniques and power converter technologies....

  13. Energy Flexibility in the Power System

    DEFF Research Database (Denmark)

    Billanes, Joy Dalmacio; Ma, Zheng; Jørgensen, Bo Nørregaard

    2017-01-01

    Energy flexibility can address the challenges of large scale integration of renewable energy resources and thereby increasing imbalance in the power system. Flexible power system can provide reliable supply, low electricity cost and sustainability. Various situations and factors influence...... the adoption of the flexibility solutions, such as flexible electricity generation, demand-response, and electricity storage. This paper tries to analyze the current energy flexibility solutions and the factors that can influence the energy flexibility adoption. This paper takes Philippines as case study...... to provide an overview of the current condition of the Philippines’ power system and discuss the energy flexibility in the Philippines’ power system. A further discussion and recommendation is conducted in the end of the paper....

  14. Optimization design for drain to nuclear power condenser

    International Nuclear Information System (INIS)

    Ding Jiapeng; Jiang Chengren

    2010-01-01

    Characters and varieties of drain to nuclear power condenser are discussed in this paper. Take the main steam system of a nuclear power as an example, normal and detailed optimization design are introduced, related expatiate are used as a reference for the drain of other systems. According to the characters of nuclear power instant operation, the influence and needed actions related with the optimization design are also analyzed. Based on the above research, the scheme has been carried out in a nuclear power station and safety for the condenser operation of the nuclear power has been improved largely. (authors)

  15. Analyzing longitudinal data with the linear mixed models procedure in SPSS.

    Science.gov (United States)

    West, Brady T

    2009-09-01

    Many applied researchers analyzing longitudinal data share a common misconception: that specialized statistical software is necessary to fit hierarchical linear models (also known as linear mixed models [LMMs], or multilevel models) to longitudinal data sets. Although several specialized statistical software programs of high quality are available that allow researchers to fit these models to longitudinal data sets (e.g., HLM), rapid advances in general purpose statistical software packages have recently enabled analysts to fit these same models when using preferred packages that also enable other more common analyses. One of these general purpose statistical packages is SPSS, which includes a very flexible and powerful procedure for fitting LMMs to longitudinal data sets with continuous outcomes. This article aims to present readers with a practical discussion of how to analyze longitudinal data using the LMMs procedure in the SPSS statistical software package.

  16. Application of the thermal efficiency analysis software 'EgWin' at existing power plants

    International Nuclear Information System (INIS)

    Koda, E.; Takahashi, T.; Nakao, Y.

    2008-01-01

    'EgWin' is the general purpose software to analyze a thermal efficiency of power system developed in CRIEPI. This software has been used to analyze the existing power generation unit of 30 or more, and the effectiveness has been confirmed. In thermal power plants, it was used for the clarification of the thermal efficiency decrease factor and the quantitative estimation of the influence that each factor gave to the thermal efficiency of the plant. Also it was used for the quantitative estimation of the effect by the operating condition change and the facility remodeling in thermal power, atomic energy, and geothermal power plants. (author)

  17. Analyzing-power measurements for 2H(n/sub pol/,n)2H scattering at 10 MeV compared to few-nucleon calculations and data for 2H(p/sub pol/,p)2H scattering

    International Nuclear Information System (INIS)

    Tornow, W.; Howell, C.R.; Byrd, R.C.; Pedroni, R.S.; Walter, R.L.

    1982-01-01

    The analyzing power A/sub y/(theta) for scattering of neutrons from deuterons at 10 MeV for 30 0 to 145 0 (c.m.) was measured to an accuracy better than +- 0.005. The results are compared to published p-d data at 10 MeV, and convincing differences are noted for the first time. These differences provide a sensitive test both of calculations for the three-nucleon system and, more importantly, of the fundamental nucleon-nucleon interaction

  18. The tensor analyzing power T20 in the dd → 3Hen and dd → 3Hp reactions at the energies 140, 200 and 270 MeV and at zero degree

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Uesaka, T.; Saito, T.

    2005-01-01

    The data on the tensor analyzing power T 20 in the dd → 3 Hen and dd → 3 Hp reactions at 140, 200 and 270 MeV of the deuteron kinetic energy and at zero degree obtained at RIKEN Accelerator Research Facility are presented. The observed positive sign of T 20 clearly demonstrates the sensitivity to the D/S wave ratios in the 3 He and 3 H in the energy domain of the measurements. The T 20 data for the 3 He-n and 3 H-p channels are in agreement within experimental accuracy

  19. CRISP90 - SOFTWARE DESIGN ANALYZER SYSTEM

    Science.gov (United States)

    Tausworthe, R. C.

    1994-01-01

    The CRISP90 Software Design Analyzer System, an update of CRISP-80, is a set of programs forming a software design and documentation tool which supports top-down, hierarchic, modular, structured design and programming methodologies. The quality of a computer program can often be significantly influenced by the design medium in which the program is developed. The medium must foster the expression of the programmer's ideas easily and quickly, and it must permit flexible and facile alterations, additions, and deletions to these ideas as the design evolves. The CRISP90 software design analyzer system was developed to provide the PDL (Programmer Design Language) programmer with such a design medium. A program design using CRISP90 consists of short, English-like textual descriptions of data, interfaces, and procedures that are imbedded in a simple, structured, modular syntax. The display is formatted into two-dimensional, flowchart-like segments for a graphic presentation of the design. Together with a good interactive full-screen editor or word processor, the CRISP90 design analyzer becomes a powerful tool for the programmer. In addition to being a text formatter, the CRISP90 system prepares material that would be tedious and error prone to extract manually, such as a table of contents, module directory, structure (tier) chart, cross-references, and a statistics report on the characteristics of the design. Referenced modules are marked by schematic logic symbols to show conditional, iterative, and/or concurrent invocation in the program. A keyword usage profile can be generated automatically and glossary definitions inserted into the output documentation. Another feature is the capability to detect changes that were made between versions. Thus, "change-bars" can be placed in the output document along with a list of changed pages and a version history report. Also, items may be marked as "to be determined" and each will appear on a special table until the item is

  20. Thermal Impact Analysis of Circulating Current in High Power Modular Online Uninterruptible Power Supplies Application

    DEFF Research Database (Denmark)

    Zhang, Chi; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In modular uninterruptible power supplies (UPSs), several DC/AC modules are required to work in parallel. This structure allows the system to be more reliable and flexible. These DC/AC modules share the same DC bus and AC critical bus. Module differences, such as filter inductor, filter capacitor......, control parameters, and so on, will make it possible for the potential zero sequence current to flow among the modules. This undesired type of circulating current will bring extra losses to the power semiconductor devices in the system, which should be paid special attention in high power application...... scenarios. In this paper, plug’n’play modules and cycle control are discussed and validated through experimental results. Moreover, potential zero sequence circulating current impact on power semiconductor devices thermal performance is also analyzed in this paper....

  1. A computational system for analyze nuclear power plants structures, made by panels, using superelements

    International Nuclear Information System (INIS)

    Jesus Miranda, C.A. de.

    1981-03-01

    The analysis of linear static behavior of folded-plate structures like the turbine building of a nuclear power plant by the Finite Element Method. Folded-plate isoparametric plane elements with 48 degrees of freedom each, 8 nodal points, in which shear deformations are considered, and super-elements, whose internal degrees of freedom are condensated, are used. Arbitrary shells can be analized too. A brief exposition of the method is present and the developing of the foregoing element and super-element is also shown. A computer program was developed for the CDC-CYBER 175 computer machine and the FORTRAN IV language was used. The coeficients of the equations system are stored by the technique of block partitioning with a compacted column storage scheme and special attention was dedicated to the preparation of the problem's data and some options were developed for this purpose. (Author) [pt

  2. A study of public acceptance of construction of atomic power plant

    International Nuclear Information System (INIS)

    Harada, Kazunori; Matsuhashi, Ryuji; Yoshida, Yoshikuni

    2011-01-01

    In June 2010, Basic Energy Plan was approved in a Cabinet meeting. It says that Japan aims to construct more than 14 atomic power plants by 2030. Today, there are 12 plans of construction of atomic power plant, but it is hard to say that their plans easily come off. That's because public acceptance of atomic power plant is low in Japan, for example local residents wage opposition campaigns. This study conducts a survey in the form of a questionnaire and analyzes it by Analytical Hierarchical Process (AHP). Analytic Hierarchy Process is a structured technique for dealing with complex decisions. A questionnaire using AHP is very easy to answer and analyze. This survey was conducted in 2 areas. First area is Hohoku-cho, Yamaguchi Pref. that had a plan of construction of atomic power plant and the plan was demolished by opposition campaigns. Second area is Kaminoseki-cho, Yamaguchi Pref. that has a plan of construction of atomic power plant now and the plan is working order. Public acceptance can be calculated from survey data of 2 areas, and it helps to understand why first area disapproved a plan of atomic power plant and second area approves it. We consider a model to analyze public acceptance. (author)

  3. Benchmarking Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jakic, I.

    2016-01-01

    One of the main tasks an owner have is to keep its business competitive on the market while delivering its product. Being owner of nuclear power plant bear the same (or even more complex and stern) responsibility due to safety risks and costs. In the past, nuclear power plant managements could (partly) ignore profit or it was simply expected and to some degree assured through the various regulatory processes governing electricity rate design. It is obvious now that, with the deregulation, utility privatization and competitive electricity market, key measure of success used at nuclear power plants must include traditional metrics of successful business (return on investment, earnings and revenue generation) as well as those of plant performance, safety and reliability. In order to analyze business performance of (specific) nuclear power plant, benchmarking, as one of the well-established concept and usual method was used. Domain was conservatively designed, with well-adjusted framework, but results have still limited application due to many differences, gaps and uncertainties. (author).

  4. Researcher/Researched: Relations of Vulnerability/Relations of Power

    Science.gov (United States)

    Huckaby, M. Francyne

    2011-01-01

    Turning to reflexive journals and fieldnotes, the author reconsiders Foucault's "relations of power" through her experiences with five research participants, who are professors of education. The paper explores: (1) the translation of Foucault for an analysis of power; (2) the dynamics of researching up and analyzing from below; and (3) the…

  5. Basic Studies on Chaotic Characteristics of Electric Power Market Price

    Science.gov (United States)

    Takeuchi, Yuya; Miyauchi, Hajime; Kita, Toshihiro

    Recently, deregulation and reform of electric power utilities have been progressing in many parts of the world. In Japan, partial deregulation has been started from generation sector since 1995 and partial deregulation of retail sector is executed through twice law revisions. Through the deregulation, because electric power is traded in the market and its price is always fluctuated, it is important for the electric power business to analyze and predict the price. Although the price data of the electric power market is time series data, it is not always proper to analyze by the linear model such as ARMA because the price sometimes changes suddenly. Therefore, in this paper, we apply the methods of chaotic time series analysis, one of non-linear analysis methods, and investigate the chaotic characteristics of the system price of JEPX.

  6. Comparative study of gas-analyzing systems designed for continuous monitoring of TPP emissions

    Science.gov (United States)

    Kondrat'eva, O. E.; Roslyakov, P. V.

    2017-06-01

    Determining the composition of combustion products is important in terms of both control of emissions into the atmosphere from thermal power plants and optimization of fuel combustion processes in electric power plants. For this purpose, the concentration of oxygen, carbon monoxide, nitrogen, and sulfur oxides in flue gases is monitored; in case of solid fuel combustion, fly ash concentration is monitored as well. According to the new nature conservation law in Russia, all large TPPs shall be equipped with continuous emission monitoring and measurement systems (CEMMS) into the atmosphere. In order to ensure the continuous monitoring of pollutant emissions, direct round-the-clock measurements are conducted with the use of either domestically produced or imported gas analyzers and analysis systems, the operation of which is based on various physicochemical methods and which can be generally used when introducing CEMMS. Depending on the type and purposes of measurement, various kinds of instruments having different features may be used. This article represents a comparative study of gas-analysis systems for measuring the content of polluting substances in exhaust gases based on various physical and physicochemical analysis methods. It lists basic characteristics of the methods commonly applied in the area of gas analysis. It is proven that, considering the necessity of the long-term, continuous operation of gas analyzers for monitoring and measurement of pollutant emissions into the atmosphere, as well as the requirements for reliability and independence from aggressive components and temperature of the gas flow, it is preferable to use optical gas analyzers for the aforementioned purposes. In order to reduce the costs of equipment comprising a CEMMS at a TPP and optimize the combustion processes, electrochemical and thermomagnetic gas analyzers may also be used.

  7. Present situation, problems and solutions of China's biomass power generation industry

    International Nuclear Information System (INIS)

    Liu, Jicheng; Wang, Sijia; Wei, Qiushuang; Yan, Suli

    2014-01-01

    With the reduction of global oil reserves, developing renewable energy has become an important issue for each country. Biomass power is an important kind of clean energy, as it has abundant resource and is environmental friendly. In the past few years, China biomass power industry has developed rapidly accompanied with some problems. This paper analyzes the current situation of China biomass power generation from several aspects such as power structure, resource distribution, investment strength, and policy environment, etc. We focus on the problems existed in practical operation and analyze the outstanding problems. At last, this paper offers several suggestions for future development on the relevant fields, such as cost, strategic planning and policy. - Highlights: • Review and analyze the internal and external environment of biomass power in China. • Summarize and classify policies of China biomass power according to time sequence. • Describe the distribution of biomass resources in China accurately on the map. • Use data to draw a picture for grasping current situation. • Provide valuable suggestions for practitioners to improve their business strategies

  8. Identity and power in Ukraine

    Directory of Open Access Journals (Sweden)

    Karina V. Korostelina

    2013-01-01

    Full Text Available This paper analyzes the coercive and legitimate forms of power in Ukraine. It describes the crisis of legitimacy in Ukraine as a contradiction between a blatantly cruel system of capitalism dominated by a few oligarchs, and the lingering remnants of a Soviet mentality. Two strategies are used by the Government to stoke the crisis. First, increased identification with ethnic or regional groups are instrumentally used by the Government to take attention from economic and class issues. Second, the incorporation of a Soviet meaning of power into the new national identity and presentation of it as core norms, believes, and values of the people of Ukraine competes with alternative Ukrainian identity concepts. The paper analyzes five main features of the Soviet meanings of power – political, social, and economic paternalism, perception of power as source of profit and violence, and the dual reality of power with the gap between official narratives of power and a real life. The process of incorporation of the Soviet concept of power into national identity is facilitated by the process of national identity formation that helped to preserve the Soviet perception of power, because of the absence of a new ideology, a lack of critical assessment of the Soviet past, an absence of the vision of outcome, an embryonic culture of democracy, and contributions of all the presidents to the preservation of the Soviet meaning of power. People justify the system as legitimate and fair for many reasons: out of historic habit and deemed moral obligations, self-interests and/or a fear of sanctions, identification with the ruler, zones of indifference, an absence of will and self-confidence, desire to support a strong leader based on ambiguity intolerance, hierarchy – enhancing ideologies, and a general tolerance of injustice. The obedience of subjects is connected with the strength of will of the subjects and the social structures of the society. In Ukraine, the

  9. Monitoring and Analyzing of Circadian and Ultradian Locomotor Activity Based on Raspberry-Pi

    Directory of Open Access Journals (Sweden)

    Vittorio Pasquali

    2016-09-01

    Full Text Available A new device based on the Raspberry-Pi to monitor the locomotion of Arctic marine invertebrates and to analyze chronobiologic data has been made, tested and deployed. The device uses infrared sensors to monitor and record the locomotor activity of the animals, which is later analyzed. The software package consists of two separate scripts: the first designed to manage the acquisition and the evolution of the experiment, the second designed to generate actograms and perform various analyses to detect periodicity in the data (e.g., Fourier power spectra, chi-squared periodograms, and Lomb–Scargle periodograms. The data acquisition hardware and the software has been previously tested during an Arctic mission with an arctic marine invertebrate.

  10. Trade secrets protection mode of nuclear power plant

    International Nuclear Information System (INIS)

    Zeng Bin

    2015-01-01

    The paper analyzes the legal environment in which nuclear power enterprises are stayed, and mainly discusses the business secret protection modes of China's nuclear power enterprises. It is expected to provide a revelation and help for these enterprises to protect their business secrets. Firstly, the paper briefly expounds the legal basis of business secret protection and China's legalization status in this regard. Then it mainly puts forward the business secret management framework and postulations for nuclear power enterprises, and key points in application and protection of nuclear power business secret. (author)

  11. Market power and storage in electricity markets

    International Nuclear Information System (INIS)

    Skaar, Jostein

    2004-05-01

    Market power in liberalised electricity markets dominated by hydropower is analyzed in four chapters. The existing literature on competition in hydropower markets is briefly presented and examined. Chapter 1 discusses the effects of market power in the context of acquisitions in a situation where transmission capacity is constrained. Chapter 2 and 3 elaborate on the issue of competition and market power when water inflow is uncertain, and finally Chapter 4 focuses on the supply function equilibrium model in the context of a hydropower market

  12. Power quality assessment

    International Nuclear Information System (INIS)

    Fathi, H.M.E.

    2012-01-01

    The electrical power systems are exposed to different types of power quality disturbances problems. Assessment of power quality is necessary for maintaining accurate operation of sensitive equipment's especially for nuclear installations, it also ensures that unnecessary energy losses in a power system are kept at a minimum which lead to more profits. With advanced in technology growing of industrial / commercial facilities in many region. Power quality problems have been a major concern among engineers; particularly in an industrial environment, where there are many large-scale type of equipment. Thus, it would be useful to investigate and mitigate the power quality problems. Assessment of Power quality requires the identification of any anomalous behavior on a power system, which adversely affects the normal operation of electrical or electronic equipment. The choice of monitoring equipment in a survey is also important to ascertain a solution to these power quality problems. A power quality assessment involves gathering data resources; analyzing the data (with reference to power quality standards); then, if problems exist, recommendation of mitigation techniques must be considered. The main objective of the present work is to investigate and mitigate of power quality problems in nuclear installations. Normally electrical power is supplied to the installations via two sources to keep good reliability. Each source is designed to carry the full load. The Assessment of power quality was performed at the nuclear installations for both sources at different operation conditions. The thesis begins with a discussion of power quality definitions and the results of previous studies in power quality monitoring. The assessment determines that one source of electricity was deemed to have relatively good power quality; there were several disturbances, which exceeded the thresholds. Among of them are fifth harmonic, voltage swell, overvoltage and flicker. While the second

  13. Miniature mass analyzer

    CERN Document Server

    Cuna, C; Lupsa, N; Cuna, S; Tuzson, B

    2003-01-01

    The paper presents the concept of different mass analyzers that were specifically designed as small dimension instruments able to detect with great sensitivity and accuracy the main environmental pollutants. The mass spectrometers are very suited instrument for chemical and isotopic analysis, needed in environmental surveillance. Usually, this is done by sampling the soil, air or water followed by laboratory analysis. To avoid drawbacks caused by sample alteration during the sampling process and transport, the 'in situ' analysis is preferred. Theoretically, any type of mass analyzer can be miniaturized, but some are more appropriate than others. Quadrupole mass filter and trap, magnetic sector, time-of-flight and ion cyclotron mass analyzers can be successfully shrunk, for each of them some performances being sacrificed but we must know which parameters are necessary to be kept unchanged. To satisfy the miniaturization criteria of the analyzer, it is necessary to use asymmetrical geometries, with ion beam obl...

  14. Oxygen vacancy doping of hematite analyzed by electrical conductivity and thermoelectric power measurements

    Science.gov (United States)

    Mock, Jan; Klingebiel, Benjamin; Köhler, Florian; Nuys, Maurice; Flohre, Jan; Muthmann, Stefan; Kirchartz, Thomas; Carius, Reinhard

    2017-11-01

    Hematite (α -F e2O3 ) is known for poor electronic transport properties, which are the main drawback of this material for optoelectronic applications. In this study, we investigate the concept of enhancing electrical conductivity by the introduction of oxygen vacancies during temperature treatment under low oxygen partial pressure. We demonstrate the possibility of tuning the conductivity continuously by more than five orders of magnitude during stepwise annealing in a moderate temperature range between 300 and 620 K. With thermoelectric power measurements, we are able to attribute the improvement of the electrical conductivity to an enhanced charge-carrier density by more than three orders of magnitude. We compare the oxygen vacancy doping of hematite thin films with hematite nanoparticle layers. Thereby we show that the dominant potential barrier that limits charge transport is either due to grain boundaries in hematite thin films or due to potential barriers that occur at the contact area between the nanoparticles, rather than the potential barrier within the small polaron hopping model, which is usually applied for hematite. Furthermore, we discuss the transition from oxygen-deficient hematite α -F e2O3 -x towards the magnetite F e3O4 phase of iron oxide at high density of vacancies.

  15. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  16. Improving the economics and competitiveness of nuclear power in China

    International Nuclear Information System (INIS)

    Jing Chunning; Tian Jiashu

    2005-01-01

    A cost structure of nuclear power plant is introduced in this paper. Various factors that influence the nuclear power economics are discussed in detail. A preliminary study is carried out for the short-term new nuclear power plants in China. Focusing on the Chinese nuclear power development strategy, the short term and mid-long term economics of nuclear power in China is analyzed. Based on analysis and comparison, suggestions and proposals for improving the economics and competitiveness of nuclear power in China are provided. (authors)

  17. Low Power Very High Frequency Switch-Mode Power Supply with 50 V Input and 5 V Output

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    This paper presents the design of a resonant converter with a switching frequency in the very high frequencyrange (30-300 MHz), a large step down ratio (10 times) and low output power (1 W). Several different invertersand rectifiers are analyzed and compared. The class E inverter and rectifier...... are selected based on complexity andefficiency estimates. Three different power stages are implemented; one with a large input inductor, one with a switch with small capacitances and one with a switch with low on resistance. The power stages are designed with the same specifications and efficiencies from 60...

  18. Multidisciplinary Modelling Tools for Power Electronic Circuits

    DEFF Research Database (Denmark)

    Bahman, Amir Sajjad

    in reliability assessment of power modules, a three-dimensional lumped thermal network is proposed to be used for fast, accurate and detailed temperature estimation of power module in dynamic operation and different boundary conditions. Since an important issue in the reliability of power electronics...... environment to be used for optimization of cooling system layout with respect to thermal resistance and pressure drop reductions. Finally extraction of electrical parasitics in the multi-chip power modules will be investigated. As the switching frequency of power devices increases, the size of passive...... components are reduced considerably that leads to increase of power density and cost reduction. However, electrical parasitics become more challenging with increasing the switching frequency and paralleled chips in the integrated and denser packages. Therefore, electrical parasitic models are analyzed based...

  19. Questioning the economic viability of nuclear power

    International Nuclear Information System (INIS)

    Murota, Takeshi

    1981-01-01

    In the United States, the pioneer in nuclear power generation, the economic aspect of nuclear power is now questioned. Its economy in Japan is supported by the entirely monopolistic nature of the power generating firms. The economy of the nuclear power generation in Japan is first examined in its original cost. It is then analyzed in legislative economics. In the conventional arguments, the authorities in favor of nuclear power stick to its practical safety, acknowledging its potential danger, while the people against it adheres to its danger. Thus both arguments go in parallel, never converging. It is attempted to elucidate through the atomic energy damage compensation system, on the boundary between legislation and economy, to whom nuclear power generation is safe, and to whom it is dangerous. (J.P.N.)

  20. Modeling a TRIGA Power System with ATHENA

    International Nuclear Information System (INIS)

    Davis, C.B.

    1985-01-01

    GA Technologies TRIGA Power System (TPS) is a power-producing version of the Training Research and Isotope General Atomic (TRIGA) reactor. The TPS analyzed here is designed to produce 10 MW of electrical power. The TPS features three major thermal-hydraulic systems, including a water-filled primary coolant system, a water-filled residual heat removal system, and a Freon-filled secondary coolant system. A thermal-hydraulic model of the TPS was developed using the Advanced Thermal Hydraulic Energy Network Analyzer (ATHENA) computer code, and two demonstration calculations were performed. ATHENA is based on the Reactor Excursion and Leak Analysis Program (RELAP5/MOD2) and has similar, but expanded capabilities. The expanded capabilities allow the representation of several different fluids, including water and Freon-11. This paper provides descriptions of the TPS, the ATHENA computer code and ATHENA TPS model, results of the demonstration calculations, conclusions, and references. 2 refs., 7 figs

  1. GIS-based biomass resource utilization for rice straw cofiring in the Taiwanese power market

    International Nuclear Information System (INIS)

    Hu, Ming-Che; Huang, An-Lei; Wen, Tzai-Hung

    2013-01-01

    Rice straw, a rich agricultural byproduct in Taiwan, can be used as biomass feedstock for cofiring systems. In this study, we analyzed the penetration of rice straw cofiring systems in the Taiwanese power market. In the power generation system, rice straw is cofired with fossil fuel in existing electricity plants. The benefits of cofiring systems include increasing the use of renewable energy, decreasing the fuel cost, and lowering greenhouse gas emissions. We established a linear complementarity model to simulate the power market equilibrium with cofiring systems in Taiwan. GIS-based analysis was then used to analyze the geospatial relationships between paddy rice farms and power plants to assess potential biomass for straw-power generation. Additionally, a sensitivity analysis of the biomass feedstock supply system was conducted for various cofiring scenarios. The spatial maps and equilibrium results of rice straw cofiring in Taiwanese power market are presented in the paper. - Highlights: ► The penetration of straw cofiring systems in the power market is analyzed. ► GIS-based analysis assesses potential straw-power generation. ► The spatial maps and equilibrium results of rice straw cofiring are presented

  2. Effects of a power shortage in the Tokyo metropolitan area on awareness of nuclear power generation and power savings behavior

    International Nuclear Information System (INIS)

    Kitada, Atsuko

    2004-01-01

    The shutdown of a number of nuclear power stations of the Tokyo Electric Power Company in the summer of 2003 caused a power shortage problem in the Tokyo Metropolitan area. To examine the effects of the power shortage, in September 2003 a survey was conducted in the service areas of the Kansai Electric Power Company (Kansai region) and the Tokyo Electric Power Company (Kanto region). This survey was part of a wider opinion survey begun in 1993 concerning nuclear power generation. The results of the September 2003 survey are as follows: The degree of recognition of the power shortage problem in the Metropolitan area was high, with 40% of respondents in the Kansai region and nearly 70% in the Kanto region understanding that the shortage was caused by the shutdown of several nuclear power station. The overall awareness of nuclear power generation was little affected in both the Kansai and Kanto regions, though the sense of a shortage of the generating capacity had been raised slightly. Once respondents knew about the power shortage problem, they estimated the likelihood of an occurrence of large-scale service interruption to be low, nearly at an even chance, and they had been only slightly worried about it, essentially viewing the problem optimistically. In the Kanto region, where public relations activities for power savings had been actively pursued, the frequency of experiencing exposure to such public relations activities was remarkably higher than in the Kansai region. The relation between exposure to public relations activities for power savings and power savings behavior was analyzed using quantification method II. Analysis results suggest that public relations activities for power savings in the Kanto region had the effect of urging power savings behavior. However, the difference in the rate of putting power savings behavior into practice was small between the Kanto and Kansai regions, indicating that public relation activities for power savings in the Kanto

  3. Development of nuclear power standards and relevant system in China

    International Nuclear Information System (INIS)

    Cao Shudong

    2008-01-01

    By analyzing the history of nuclear power development and the status of nuclear power codes and standards in China, the significance and necessity to quicken the development of nuclear power standards system in China are pointed out, and the guiding ideology, development thoughts, working doctrine and development objectives are put forward in this paper. (authors)

  4. Optimal Design of Magnetic ComponentsinPlasma Cutting Power Supply

    Science.gov (United States)

    Jiang, J. F.; Zhu, B. R.; Zhao, W. N.; Yang, X. J.; Tang, H. J.

    2017-10-01

    Phase-shifted transformer and DC reactor are usually needed in chopper plasma cutting power supply. Because of high power rate, the loss of magnetic components may reach to several kilowatts, which seriously affects the conversion efficiency. Therefore, it is necessary to research and design low loss magnetic components by means of efficient magnetic materials and optimal design methods. The main task in this paper is to compare the core loss of different magnetic material, to analyze the influence of transformer structure, winding arrangement and wire structure on the characteristics of magnetic component. Then another task is to select suitable magnetic material, structure and wire in order to reduce the loss and volume of magnetic components. Based on the above outcome, the optimization design process of transformer and dc reactor are proposed in chopper plasma cutting power supply with a lot of solutions. These solutions are analyzed and compared before the determination of the optimal solution in order to reduce the volume and power loss of the two magnetic components and improve the conversion efficiency of plasma cutting power supply.

  5. Price-based control of ancillary services for power balancing

    NARCIS (Netherlands)

    Bosch, van den P.P.J.; Jokic, A.; Frunt, J.; Kling, W.L.; Nobel, Frank; Boonekamp, P.; Boer, de W.; Hermans, R.M.; Virag, A.

    2011-01-01

    A reliable and an efficient power system is a necessity for any industrialized society. Governments have to enforce regulations to guarantee that such a power system, in spite of many competing stakeholders, participants, companies, and regulating agencies can be operational. This paper analyzes the

  6. Ash Deposition Trials at Three Power Stations in Denmark

    DEFF Research Database (Denmark)

    Laursen, Karin; Frandsen, Flemming; Larsen, Ole Hede

    1998-01-01

    Six full-scale trials were conducted at three power stations in Denmark: Ensted, Funen, and Vendsyssel power stations. During these trials, pulverized coal, bottom ash, fly ash, and deposits from cooled probes were sampled and analyzed with various techniques. On the basis of SEM analyses...

  7. Gross greenhouse gas fluxes from hydro-power reservoir compared to thermo-power plants

    International Nuclear Information System (INIS)

    Santos, Marco Aurelio dos; Pinguelli Rosa, Luiz; Sikar, Bohdan; Sikar, Elizabeth; Santos, Ednaldo Oliveira dos

    2006-01-01

    This paper presents the findings of gross carbon dioxide and methane emissions measurements in several Brazilian hydro-reservoirs, compared to thermo power generation. The term 'gross emissions' means gas flux measurements from the reservoir surface without natural pre-impoundment emissions by natural bodies such as the river channel, seasonal flooding and terrestrial ecosystems. The net emissions result from deducting pre-existing emissions by the reservoir. A power dam emits biogenic gases such as CO 2 and CH 4 . However, studies comparing gas emissions (gross emissions) from the reservoir surface with emissions by thermo-power generation technologies show that the hydro-based option presents better results in most cases analyzed. In this study, measurements were carried in the Miranda, Barra Bonita, Segredo, Tres Marias, Xingo, and Samuel and Tucurui reservoirs, located in two different climatological regimes. Additional data were used here from measurements taken at the Itaipu and Serra da Mesa reservoirs. Comparisons were also made between emissions from hydro-power plants and their thermo-based equivalents. Bearing in mind that the estimated values for hydro-power plants include emissions that are not totally anthropogenic, the hydro-power plants studied generally posted lower emissions than their equivalent thermo-based counterparts. Hydro-power complexes with greater power densities (capacity/area flooded-W/m 2 ), such as Itaipu, Xingo, Segredo and Miranda, have the best performance, well above thermo-power plants using state-of-the-art technology: combined cycle fueled by natural gas, with 50% efficiency. On the other hand, some hydro-power complexes with low-power density perform only slightly better or even worse than their thermo-power counterparts

  8. Spatial dependencies of wind power and interrelations with spot price dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Elberg, Christina; Hagspiel, Simeon

    2013-06-15

    Wind power has seen a strong growth over the last decade. Due to its high intermittency, spot prices have become more volatile and exhibit correlated behavior with wind power fed into the system. In this paper, we develop a stochastic simulation model that incorporates the spatial dependencies of wind power and its interrelations with spot prices: We employ a structural supply and demand based model for the electricity spot price that takes into account stochastic production quantities of wind power. Spatial dependencies are modeled with the help of copulas, thus linking the single turbine wind power to the aggregated wind power in a market. The model is applied to the German electricity market where wind power already today makes up a significant share of total power production. Revenue distributions and the market value of different wind power plants are analyzed. We find that the specific location of the considered wind turbine, i.e. its spatial dependency with respect to the aggregated wind power in the system, is of high relevance for its market value. Many of the analyzed locations show an upper tail dependence that adversely impacts the market value. This effect becomes more important for increasing levels of wind power penetration.

  9. Spatial dependencies of wind power and interrelations with spot price dynamics

    International Nuclear Information System (INIS)

    Elberg, Christina; Hagspiel, Simeon

    2013-01-01

    Wind power has seen a strong growth over the last decade. Due to its high intermittency, spot prices have become more volatile and exhibit correlated behavior with wind power fed into the system. In this paper, we develop a stochastic simulation model that incorporates the spatial dependencies of wind power and its interrelations with spot prices: We employ a structural supply and demand based model for the electricity spot price that takes into account stochastic production quantities of wind power. Spatial dependencies are modeled with the help of copulas, thus linking the single turbine wind power to the aggregated wind power in a market. The model is applied to the German electricity market where wind power already today makes up a significant share of total power production. Revenue distributions and the market value of different wind power plants are analyzed. We find that the specific location of the considered wind turbine, i.e. its spatial dependency with respect to the aggregated wind power in the system, is of high relevance for its market value. Many of the analyzed locations show an upper tail dependence that adversely impacts the market value. This effect becomes more important for increasing levels of wind power penetration.

  10. Analysis of Human Errors in Japanese Nuclear Power Plants using JHPES/JAESS

    International Nuclear Information System (INIS)

    Kojima, Mitsuhiro; Mimura, Masahiro; Yamaguchi, Osamu

    1998-01-01

    CRIEPI (Central Research Institute for Electric Power Industries) / HFC (Human Factors research Center) developed J-HPES (Japanese version of Human Performance Enhancement System) based on the HPES which was originally developed by INPO to analyze events resulted from human errors. J-HPES was systematized into a computer program named JAESS (J-HPES Analysis and Evaluation Support System) and both systems were distributed to all Japanese electric power companies to analyze events by themselves. CRIEPI / HFC also analyzed the incidents in Japanese nuclear power plants (NPPs) which were officially reported and identified as human error related with J-HPES / JAESS. These incidents have numbered up to 188 cases over the last 30 years. An outline of this analysis is given, and some preliminary findings are shown. (authors)

  11. Buoy-Rope-Drum Wave Power System

    Directory of Open Access Journals (Sweden)

    Linsen Zhu

    2013-01-01

    Full Text Available A buoy-rope-drum wave power system is a new type of floating oscillating buoy wave power device, which absorbs energy from waves by buoy-rope-drum device. Based on the linear deep water wave theory and pure resistive load, with cylinder buoy as an example, the research sets up the theoretical model of direct-drive buoy-rope-drum wave power efficiency and analyzes the influence of the mass and load of the system on its generating efficiency. It points out the two main categories of the efficient buoy-rope-drum wave power system: light thin type and resonance type, and optimal designs of their major parameters are carried out on the basis of the above theoretical model of generating efficiency.

  12. Study on diagnostic plant analyzer method for support of emergency operation

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Gofuku, A.; Itoh, K.; Wakabayashi, J.

    1986-01-01

    Methods of time-critical diagnostic plant analyzer are investigated which would serve as support to emergency operation of nuclear power plant. A faster-than-real-time simulator code TOKRAC is developed for analyzing PWR primary loop thermo-hydraulics of small-break LOCA and it is applied for a numerical experiment of initial phase of TMI-2 accident. TOKRAC resulted in a good agreement with a RELAP4/MOD6 calculation and the plant record with as fast as can one-tenth of real time. A real-time estimator of SG heat transfer rate based on Kalman filter is proposed and its applicability is verified using LOFT ATWS experimental data. With regards to how to integrate those methods into the software system in operation support center, a new concept of module-based simulation system is proposed which aims at offering a flexible and human-cognitive oriented environment for various analytical tool development

  13. Plant analyzer for high-speed interactive simulation of BWR plant transients

    International Nuclear Information System (INIS)

    Cheng, H.S.; Lekach, S.V.; Mallen, A.N.; Wulff, W.; Cerbone, R.J.

    1984-01-01

    A combination of advanced modeling techniques and modern, special-purpose peripheral minicomputer technology was utilized to develop a plant analyzer which affords realistic predictions of plant transients and severe off-normal events in LWR power plants through on-line simulations at speeds up to 10 times faster than actual process speeds. The mathematical models account for nonequilibrium, nonhomogeneous two-phase flow effects in the coolant, for acoustical effects in the steam line and for the dynamics of the entire balance of the plant. Reactor core models include point kinetics with reactivity feedback due to void fraction, fuel temperature, coolant temperature, and boron concentration as well as a conduction model for predicting fuel and clad temperatures. Control systems and trip logic for plant protection systems are also simulated. The AD10 of Applied Dynamics International, a special-purpose peripheral processor, is used as the principal hardware of the plant analyzer

  14. Analyzing Peace Pedagogies

    Science.gov (United States)

    Haavelsrud, Magnus; Stenberg, Oddbjorn

    2012-01-01

    Eleven articles on peace education published in the first volume of the Journal of Peace Education are analyzed. This selection comprises peace education programs that have been planned or carried out in different contexts. In analyzing peace pedagogies as proposed in the 11 contributions, we have chosen network analysis as our method--enabling…

  15. A measurement to analyze the relative change in the Absolute Parity of Power Purchase: An application to the European Union

    OpenAIRE

    Santiago Rodriguez Feijoo; Alejandro Rodriguez Caro; Carlos Gonzalez Correa

    2003-01-01

    In the present paper an index to measure the changes in the Absolute Purchasing Power Parity. in the short term of a group of territories that conform an unique market, using the information of the Harmonized Index of Consumer Prices and the Exchange Rates. This measurement is utilized to study the change in relative prices of the countries of the European Union for the period 1991-2002, and the fulfillment of the theory of the Relative Purchasing Power Parity, taking as a reference the Absol...

  16. Development of software to improve AC power quality on large spacecraft

    Science.gov (United States)

    Kraft, L. Alan

    1991-01-01

    To insure the reliability of a 20 kHz, alternating current (AC) power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can become a serious problem. It can cause malfunctions in equipment that the power system is supplying, and, during distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. To address the harmonic distortion issue, work was begun under the 1990 NASA-ASEE Summer Faculty Fellowship Program. Software, originally developed by EPRI, called HARMFLO, a power flow program capable of analyzing harmonic conditions on three phase, balanced, 60 Hz AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The modelling was also started under the same fellowship work period. Details of the modifications and models completed during the 1990 NASA-ASEE Summer Faculty Fellowship Program can be found in a project report. As a continuation of the work to develop a complete package necessary for the full analysis of spacecraft AC power system behavior, deployment work has continued through NASA Grant NAG3-1254. This report details the work covered by the above mentioned grant.

  17. Performance analyses of a hybrid geothermal–fossil power generation system using low-enthalpy geothermal resources

    International Nuclear Information System (INIS)

    Liu, Qiang; Shang, Linlin; Duan, Yuanyuan

    2016-01-01

    Highlights: • Geothermal energy is used to preheat the feedwater in a coal-fired power unit. • The performance of a hybrid geothermal–fossil power generation system is analyzed. • Models for both parallel and serial geothermal preheating schemes are presented. • Effects of geothermal source temperatures, distances and heat losses are analyzed. • Power increase of the hybrid system over an ORC and tipping distance are discussed. - Abstract: Low-enthalpy geothermal heat can be efficiently utilized for feedwater preheating in coal-fired power plants by replacing some of the high-grade steam that can then be used to generate more power. This study analyzes a hybrid geothermal–fossil power generation system including a supercritical 1000 MW power unit and a geothermal feedwater preheating system. This study models for parallel and serial geothermal preheating schemes and analyzes the thermodynamic performance of the hybrid geothermal–fossil power generation system for various geothermal resource temperatures. The models are used to analyze the effects of the temperature matching between the geothermal water and the feedwater, the heat losses and pumping power during the geothermal water transport and the resource distance and temperature on the power increase to improve the power generation. The serial geothermal preheating (SGP) scheme generally generates more additional power than the parallel geothermal preheating (PGP) scheme for geothermal resource temperatures of 100–130 °C, but the SGP scheme generates slightly less additional power than the PGP scheme when the feedwater is preheated to as high a temperature as possible before entering the deaerator for geothermal resource temperatures higher than 140 °C. The additional power decreases as the geothermal source distance increases since the pipeline pumping power increases and the geothermal water temperature decreases due to heat losses. More than 50% of the power decrease is due to geothermal

  18. Resolution of point sources of light as analyzed by quantum detection theory.

    Science.gov (United States)

    Helstrom, C. W.

    1973-01-01

    The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  19. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  20. Analyzing the User-Generated Content on Disintermediation Effect: A Latent Segmentation Study of Bookers and Lookers

    NARCIS (Netherlands)

    Lorenzo Romero, Carlota; Del Chiappa, Giacomo; Constantinides, Efthymios; Nah, Fiona Fui-Hoon

    2014-01-01

    This study analyzes the perceptions of different groups of consumers for and against the disintermediation of travel agencies also considering the relative power in influencing the tourist’s choices exerted by user generated-content (UGC). A web-based survey is carried out in Spain and 961complete

  1. Assessment of post-Fukushima renewable energy policy in Japan's nation-wide power grid

    International Nuclear Information System (INIS)

    Komiyama, Ryoichi; Fujii, Yasumasa

    2017-01-01

    This manuscript analyzes an optimal power generation mix in Japan's nation-wide power grid by considering the post-Fukushima energy policy which puts a high priority on expanding renewable energy. The study is performed, employing an optimal power generation mix model which is characterized by detailed geographical resolution derived from 135 nodes and 166 high-voltage power transmission lines with 10-min temporal resolution. Simulated results reveal that renewable energy promotion policy underlies the necessity for capacity expansion of inter- or intra-regional power transmission lines in Japan in order to realize economical power system operation. In addition, the results show that the integration of massive variable renewable (VR) such as PV and wind decreases the capacity factor of power plant including ramp generator and possibly affects that profitability, which implies the challenge to ensure power system adequacy enough to control VR variability. - Highlights: • Authors analyze installable potential of renewable by Japan's power grid model. • Power grid of the model includes 135 nodes and 166 power transmission lines. • Renewable promotion underlies the necessity for capacity expansion of power lines. • Unremunerated power plants affect power grid adequacy under extensive renewable.

  2. Power Generation Technology Choice in the Presence of Climate Policy

    International Nuclear Information System (INIS)

    Pettersson, Fredrik

    2005-01-01

    The overall purpose of this thesis is to analyze power generation technology choices in the presence of climate policy. Special attention is paid to the diffusion of renewable power technologies following a carbon pricing policy, and this topic is analyzed in two self-contained papers. The overall objective of paper 1 is to analyze how future investments in the Swedish power sector can be affected by carbon pricing policies following the Kyoto Protocol. In the first part we focus on the price of carbon following the Kyoto commitments and to what extent this policy will affect the relative competitiveness of the available investment alternatives. The second part pays attention to the possible impacts of technology learning - and the resulting cost decreases - on the economics of power generation in the presence of climate policy. The first part considers the majority of power generation technologies available in Sweden, while the second part focuses solely on the competition between combined cycle natural gas plants and the cheapest renewable power alternative, wind power. Methodologically, we approach the above issues from the perspective of a power generator who considers investing in new generation capacity. This implies that we first of all assess the lifetime engineering costs of different power generation technologies in Sweden, and analyze the impact of carbon pricing on the competitive cost position of these technologies under varying rate-of-return requirements. Overall the results indicate that in general it is not certain that compliance with the Kyoto commitments implies substantial increases in renewable power sources. If, therefore, renewable power sources are favored for reasons beyond climate policy additional policy instruments will be needed. The purpose of paper 2 is to analyze the costs for reducing CO 2 emissions in the power-generating sectors in Croatia, the European part of Russia, Macedonia, Serbia and the Ukraine in 2020 by using a linear

  3. Implicit Particle Filter for Power System State Estimation with Large Scale Renewable Power Integration.

    Science.gov (United States)

    Uzunoglu, B.; Hussaini, Y.

    2017-12-01

    Implicit Particle Filter is a sequential Monte Carlo method for data assimilation that guides the particles to the high-probability by an implicit step . It optimizes a nonlinear cost function which can be inherited from legacy assimilation routines . Dynamic state estimation for almost real-time applications in power systems are becomingly increasingly more important with integration of variable wind and solar power generation. New advanced state estimation tools that will replace the old generation state estimation in addition to having a general framework of complexities should be able to address the legacy software and able to integrate the old software in a mathematical framework while allowing the power industry need for a cautious and evolutionary change in comparison to a complete revolutionary approach while addressing nonlinearity and non-normal behaviour. This work implements implicit particle filter as a state estimation tool for the estimation of the states of a power system and presents the first implicit particle filter application study on a power system state estimation. The implicit particle filter is introduced into power systems and the simulations are presented for a three-node benchmark power system . The performance of the filter on the presented problem is analyzed and the results are presented.

  4. Assessment and mitigation of power quality problems for PUSPATI TRIGA Reactor (RTP)

    Science.gov (United States)

    Zakaria, Mohd Fazli; Ramachandaramurthy, Vigna K.

    2017-01-01

    An electrical power systems are exposed to different types of power quality disturbances. Investigation and monitoring of power quality are necessary to maintain accurate operation of sensitive equipment especially for nuclear installations. This paper will discuss the power quality problems observed at the electrical sources of PUSPATI TRIGA Reactor (RTP). Assessment of power quality requires the identification of any anomalous behavior on a power system, which adversely affects the normal operation of electrical or electronic equipment. A power quality assessment involves gathering data resources; analyzing the data (with reference to power quality standards) then, if problems exist, recommendation of mitigation techniques must be considered. Field power quality data is collected by power quality recorder and analyzed with reference to power quality standards. Normally the electrical power is supplied to the RTP via two sources in order to keep a good reliability where each of them is designed to carry the full load. The assessment of power quality during reactor operation was performed for both electrical sources. There were several disturbances such as voltage harmonics and flicker that exceeded the thresholds. To reduce these disturbances, mitigation techniques have been proposed, such as to install passive harmonic filters to reduce harmonic distortion, dynamic voltage restorer (DVR) to reduce voltage disturbances and isolate all sensitive and critical loads.

  5. Directory of nuclear power plants in the world, 1985

    International Nuclear Information System (INIS)

    Fujii, Haruo

    1985-01-01

    This book presents technical information and estimates trends of load factors and construction costs of nuclear power plants. Particularly road maps indicating plants are drawn in, which would be practical in visiting them. The data used here are directly confirmed by operators in every part of the world. Therefore, they reflect up-to-date nuclear power developments and its future. This allows wide and exact understanding of world's nuclear power. Chapter 1 presents nuclear power growth around the world and estimates forecasts based on information from electric power companies: nuclear power growths and the growths in the number of reactors around the world, in WOCA (World outside the Centrally Planned Economies Area), in CPEA (Centrally Planned Economies Area) are analyzed in detail. Chapter 2 presents nuclear power plants on maps by country. The maps show exact locations of nuclear power plants with local cities around them, rivers and lakes. For convenience, symbols are given to aid in identifying the types of reactors. Chapter 3 presents general information of nuclear power plants. Also the addresses of operators, all segments of nuclear power supply industries and nuclear organizations are included. For convenience, the index of nuclear power plants is added. Chapter 4 presents technical information, road maps in large scales and photographs of nuclear power plants in the world. The road maps show exact locations of plants. Chapter 5 presents operating experiences, load factors, refuelling and maintenance outages. The trends of data are analyzed both regionally (WOCA, CPEA) and world-widely. Chapter 6 presents trends of construction costs, component costs as percent of total construction costs and direct costs, and construction durations. (J.P.N.)

  6. Risk analyses of nuclear power plants

    International Nuclear Information System (INIS)

    Jehee, J.N.T.; Seebregts, A.J.

    1991-02-01

    Probabilistic risk analyses of nuclear power plants are carried out by systematically analyzing the possible consequences of a broad spectrum of causes of accidents. The risk can be expressed in the probabilities for melt down, radioactive releases, or harmful effects for the environment. Following risk policies for chemical installations as expressed in the mandatory nature of External Safety Reports (EVRs) or, e.g., the publication ''How to deal with risks'', probabilistic risk analyses are required for nuclear power plants

  7. Development of the MARS input model for Ulchin 1/2 transient analyzer

    International Nuclear Information System (INIS)

    Jeong, J. J.; Kim, K. D.; Lee, S. W.; Lee, Y. J.; Chung, B. D.; Hwang, M.

    2003-03-01

    KAERI has been developing the NSSS transient analyzer based on best-estimate codes for Ulchin 1/2 plants. The MARS and RETRAN code are used as the best-estimate codes for the NSSS transient analyzer. Among the two codes, the MARS code is to be used for realistic analysis of small- and large-break loss-of-coolant accidents, of which break size is greater than 2 inch diameter. This report includes the input model requirements and the calculation note for the Ulchin 1/2 MARS input data generation (see the Appendix). In order to confirm the validity of the input data, we performed the calculations for a steady state at 100 % power operation condition and a double-ended cold leg break LOCA. The results of the steady-state calculation agree well with the design data. The results of the LOCA calculation seem to be reasonable and consistent with those of other best-estimate calculations. Therefore, the MARS input data can be used as a base input deck for the MARS transient analyzer for Ulchin 1/2

  8. Safety culture in nuclear power enterprise

    International Nuclear Information System (INIS)

    Zou Zhengyu; Su Luming

    2008-01-01

    The International Atomic Energy Agency (IAEA) introduced the concept of safety culture when analyzing the Chernobyl accident. Safety culture has now been widely accepted and practiced by nuclear enterprise in the world. As an important safeguard for nuclear safety, safety culture has become the core of nuclear power enterprise and entitled as the soul of nuclear enterprise. This paper analyzes the three levels of safety culture and describes its three developing phases. (authors)

  9. Towards a Reactive Power Oscillation Damping Controller for Wind Power Plant Based on Full Converter Wind Turbines

    DEFF Research Database (Denmark)

    Knüppel, Thyge; Kumar, Sathess; Thuring, Patrik

    2012-01-01

    In this paper a power oscillation damping controller (POD) based on modulation of reactive power (Q POD) is analyzed where the modular and distributed characteristics of the wind power plant (WPP) are considered. For a Q POD it is essential that the phase of the modulated output is tightly...... contributes to a collective response. This ability is shown with a 150 wind turbine (WT) WPP with all WTs represented, and it is demonstrated that the WPP contributes to the inter-area damping. The work is based on a nonlinear, dynamic model of the 3.6 MW Siemens Wind Power WT....... controlled to achieve a positive damping contribution. It is investigated how a park level voltage, reactive power, and power factor control at different grid strengths interact with the Q POD in terms of a resulting phase shift. A WPP is modular and distributed and a WPP Q POD necessitate that each WT...

  10. Village power options

    Energy Technology Data Exchange (ETDEWEB)

    Lilienthal, P. [National Renewable Energy Laboratory, Golden, CO (United States)

    1997-12-01

    This paper describes three different computer codes which have been written to model village power applications. The reasons which have driven the development of these codes include: the existance of limited field data; diverse applications can be modeled; models allow cost and performance comparisons; simulations generate insights into cost structures. The models which are discussed are: Hybrid2, a public code which provides detailed engineering simulations to analyze the performance of a particular configuration; HOMER - the hybrid optimization model for electric renewables - which provides economic screening for sensitivity analyses; and VIPOR the village power model - which is a network optimization model for comparing mini-grids to individual systems. Examples of the output of these codes are presented for specific applications.

  11. Use of wind power forecasting in operational decisions.

    Energy Technology Data Exchange (ETDEWEB)

    Botterud, A.; Zhi, Z.; Wang, J.; Bessa, R.J.; Keko, H.; Mendes, J.; Sumaili, J.; Miranda, V. (Decision and Information Sciences); (INESC Porto)

    2011-11-29

    The rapid expansion of wind power gives rise to a number of challenges for power system operators and electricity market participants. The key operational challenge is to efficiently handle the uncertainty and variability of wind power when balancing supply and demand in ths system. In this report, we analyze how wind power forecasting can serve as an efficient tool toward this end. We discuss the current status of wind power forecasting in U.S. electricity markets and develop several methodologies and modeling tools for the use of wind power forecasting in operational decisions, from the perspectives of the system operator as well as the wind power producer. In particular, we focus on the use of probabilistic forecasts in operational decisions. Driven by increasing prices for fossil fuels and concerns about greenhouse gas (GHG) emissions, wind power, as a renewable and clean source of energy, is rapidly being introduced into the existing electricity supply portfolio in many parts of the world. The U.S. Department of Energy (DOE) has analyzed a scenario in which wind power meets 20% of the U.S. electricity demand by 2030, which means that the U.S. wind power capacity would have to reach more than 300 gigawatts (GW). The European Union is pursuing a target of 20/20/20, which aims to reduce greenhouse gas (GHG) emissions by 20%, increase the amount of renewable energy to 20% of the energy supply, and improve energy efficiency by 20% by 2020 as compared to 1990. Meanwhile, China is the leading country in terms of installed wind capacity, and had 45 GW of installed wind power capacity out of about 200 GW on a global level at the end of 2010. The rapid increase in the penetration of wind power into power systems introduces more variability and uncertainty in the electricity generation portfolio, and these factors are the key challenges when it comes to integrating wind power into the electric power grid. Wind power forecasting (WPF) is an important tool to help

  12. Power Consumption Based Android Malware Detection

    Directory of Open Access Journals (Sweden)

    Hongyu Yang

    2016-01-01

    Full Text Available In order to solve the problem that Android platform’s sand-box mechanism prevents security protection software from accessing effective information to detect malware, this paper proposes a malicious software detection method based on power consumption. Firstly, the mobile battery consumption status information was obtained, and the Gaussian mixture model (GMM was built by using Mel frequency cepstral coefficients (MFCC. Then, the GMM was used to analyze power consumption; malicious software can be classified and detected through classification processing. Experiment results demonstrate that the function of an application and its power consumption have a close relationship, and our method can detect some typical malicious application software accurately.

  13. Sexual Harassment, Workplace Authority, and the Paradox of Power

    Science.gov (United States)

    McLaughlin, Heather; Uggen, Christopher; Blackstone, Amy

    2012-01-01

    Power is at the core of feminist theories of sexual harassment, although it has rarely been measured directly in terms of workplace authority. Popular characterizations portray male supervisors harassing female subordinates, but power-threat theories suggest that women in authority may be more frequent targets. This article analyzes longitudinal…

  14. PUMA code simulation of recovery power transients after a short shutdown of the Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Villar, Javier; Pomerantz, Marcelo E.

    2003-01-01

    A simulation of recovery power transients after a short shutdown on Embalse nuclear power plant equilibrium core with slightly enriched uranium fuel was performed in order to know the response of the reactor under such conditions. Also, comparison against the same event in a natural uranium core were done. No significant restrictions were found in operating with enriched fuel in the conditions of the analyzed event and in fact, slightly differences arose with natural uranium fuels. (author)

  15. POTENTIAL CONSEQUENCES OF THE DEREGULATION POLICY FOR THE ISRAELI POWER INDUSTRY

    Energy Technology Data Exchange (ETDEWEB)

    Deich, I.; Elmakais, D.; Frant, S.

    2007-07-01

    This paper describes the outcomes of a study prepared by the system planners of the Israel Electric Corp. It is intended to reveal general trends expected from opening of the Israeli power generation market to competition and to analyze possible implications of the different behavior of competitive markets compared to a regulated monopoly on electricity prices, system reliability, market stability and medium- and long-term development of the Israeli power system. It is the first work analyzing this issue in Israel, which was based on simulations of the Israeli power system functioning under competition for a comprehensive set of scenarios regarding possible future. (auth)

  16. Energy policy study. Volume 10. Nuclear power regulation

    International Nuclear Information System (INIS)

    Nikodem, Z.D.; Reynolds, A.W.; Clark, R.G.

    1980-05-01

    This report examines the programs for regulating the safety, design, and operation of domestic nuclear power plants. The first part of the study describes the Federal and State regulatory procedures. It describes the legal foundations for the Federal licensing process and the associated State regulatory activities. It then analyzes the aspects of these procedures that affect the cost and supply of nuclear-generated electricity. The second part of this study examines the effects of nuclear safety regulations on the planning and construction lead time for nuclear power stations, the cost of nuclear power, and, ultimately, the decision to invest in nuclear power

  17. Analysis of losses within SMES system for compensating output fluctuation of wind power farm

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. I.; Kim, J. H.; Le, T. D.; Lee, D. H.; Kim, H. M. [Jeju National University, Jeju (Korea, Republic of); Yoon, Y. S. [Dept. of Electrical Engineering, Shin Ansan University, Ansan (Korea, Republic of); Yoon, K. Y. [Dept. of lectrical and Electronic Engineering, Yonsei University, Seoul (Korea, Republic of)

    2014-12-15

    Output fluctuation which is generated in wind power farm can hinder stability of total power system. The electric energy storage (EES) reduces unstable output, and superconducting magnetic energy storage (SMES) of various EESs has the proper performance for output compensation of wind power farm since it charges and discharges large scale power quickly with high efficiency. However, because of the change of current within SMES, the electromagnetic losses occur in the process of output compensation. In this paper, the thermal effect of the losses that occur in SMES system while compensating in wind power farm is analyzed. The output analysis of wind power farm is processed by numerical analysis, and the losses of SMES system is analyzed by 3D finite element analysis (FEA) simulation tool.

  18. Analysis of losses within SMES system for compensating output fluctuation of wind power farm

    International Nuclear Information System (INIS)

    Park, S. I.; Kim, J. H.; Le, T. D.; Lee, D. H.; Kim, H. M.; Yoon, Y. S.; Yoon, K. Y.

    2014-01-01

    Output fluctuation which is generated in wind power farm can hinder stability of total power system. The electric energy storage (EES) reduces unstable output, and superconducting magnetic energy storage (SMES) of various EESs has the proper performance for output compensation of wind power farm since it charges and discharges large scale power quickly with high efficiency. However, because of the change of current within SMES, the electromagnetic losses occur in the process of output compensation. In this paper, the thermal effect of the losses that occur in SMES system while compensating in wind power farm is analyzed. The output analysis of wind power farm is processed by numerical analysis, and the losses of SMES system is analyzed by 3D finite element analysis (FEA) simulation tool.

  19. Analysis of Axial Turbine Pico-Hydro Electrical Power Plant in North Sulawesi Indonesia

    Science.gov (United States)

    Sangari, F. J.; Rompas, P. T. D.

    2018-02-01

    This study presents analysis of pico-hydro electrical power plant in North Sulawesi, Indonesia. The objective of this study is to get a design of axial turbine pico-hydro electrical power plant. The method used the study of literature, survey the construction site of the power plant and the characteristics of the location being a place of study, analysis of hydropower ability and analyzing costs of power plant. The result showed that the design of axial turbine pico-hydro installation is connected to a generator to produce electrical energy maximum can be used for household needs in villages. This analyze will be propose to local government of Minahasa, North Sulawesi, Indonesia.

  20. Research on the pricing system of online nuclear power

    International Nuclear Information System (INIS)

    Xu Dan

    2010-01-01

    National Development and Reform Commission Issues 'Long-term Nuclear Power Development Plan (2005-2020)' in October, 2007. It is the milestone for great development of the nuclear power plant. By the end of the first half of 2009, the nuclear power companies, mainly leading by CNNC and CGNPC, are busy in expanding the new project investment scale of the nuclear power. They gradually initialize the enormous nuclear investment in Zhejiang, Liaoning, Shandong, Guangxi Province and some other place. Along with the development of the nuclear plant and the reformation of the electricity price, the online electricity price of the nuclear power plant will likely be revised. How long will the price policy of 'One to one price' for each type of plant be hold? How will the online electricity price be set in the future? What kind of theories will be followed in the new pricing policy? And what kind of influence will it have on the operating and constructing nuclear power plants? All these will be the problem to the nuclear power plant. There are a lot of uncertainties in front of the nuclear power enterprise in the future. The article analyzes the cost structure of the nuclear power enterprise. Based on the price theory of the market economy, and after benchmarking with the coal power and some other industries, the article studies the future pricing policy of the nuclear power enterprise. And the article analyzes the future management risk of the nuclear power enterprise after the pricing policy reformation. And through the management improvement, the nuclear power company could response effectively to the price regulation, and minimize the uncertainty caused by the pricing policy reformation to the enterprise operation and management. (author)

  1. Charge Analyzer Responsive Local Oscillations

    Science.gov (United States)

    Krause, Linda Habash; Thornton, Gary

    2015-01-01

    The first transatlantic radio transmission, demonstrated by Marconi in December of 1901, revealed the essential role of the ionosphere for radio communications. This ionized layer of the upper atmosphere controls the amount of radio power transmitted through, reflected off of, and absorbed by the atmospheric medium. Low-frequency radio signals can propagate long distances around the globe via repeated reflections off of the ionosphere and the Earth's surface. Higher frequency radio signals can punch through the ionosphere to be received at orbiting satellites. However, any turbulence in the ionosphere can distort these signals, compromising the performance or even availability of space-based communication and navigations systems. The physics associated with this distortion effect is analogous to the situation when underwater images are distorted by convecting air bubbles. In fact, these ionospheric features are often called 'plasma bubbles' since they exhibit some of the similar behavior as underwater air bubbles. These events, instigated by solar and geomagnetic storms, can cause communication and navigation outages that last for hours. To help understand and predict these outages, a world-wide community of space scientists and technologists are devoted to researching this topic. One aspect of this research is to develop instruments capable of measuring the ionospheric plasma bubbles. Figure 1 shows a photo of the Charge Analyzer Responsive to Local Oscillations (CARLO), a new instrument under development at NASA Marshall Space Flight Center (MSFC). It is a frequency-domain ion spectrum analyzer designed to measure the distributions of ionospheric turbulence from 1 Hz to 10 kHz (i.e., spatial scales from a few kilometers down to a few centimeters). This frequency range is important since it focuses on turbulence scales that affect VHF/UHF satellite communications, GPS systems, and over-the-horizon radar systems. CARLO is based on the flight-proven Plasma Local

  2. Evaluation of the impact of power sector reforms on the Nigerian ...

    African Journals Online (AJOL)

    The electrical power industry in Nigeria has been in a deplorable state for many years. Large, medium and small scale industries suffer adverse effects due to poor services from power utility, which results in dire consequences on the nation's economy. This paper analyzes the economic effects of the power sector reforms ...

  3. Power inverter design for ASDEX Upgrade saddle coils

    Energy Technology Data Exchange (ETDEWEB)

    Teschke, M., E-mail: teschke@ipp.mpg.de [Max Planck Institute for Plasma Physics, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany); Suttrop, W.; Rott, M. [Max Planck Institute for Plasma Physics, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany)

    2013-10-15

    Highlights: ► A cost effective inverter topology for AUG's 16 in-vessel saddle coils has been found. ► Use of commercially available power modules is possible. ► Exchange of reactive power between multiple inverters is possible. ► Influence of electromagnetic noise to AUG's diagnostics was measured. ► Gas insulation of electric feed through significantly depends on magnetic fields. It is protected by fast turn-off circuit. -- Abstract: A set of 16 in-vessel saddle coils has been installed in the ASDEX Upgrade (AUG) experiment since the end of 2011 [1]. To achieve full performance, it is necessary to operate them with alternating current (AC) of arbitrary waveforms. To generate spatially resolved magnetic fields, it is required to allocate separate power inverters to every single coil. Therefore, different topologies are analyzed and compared. Studies of the commutation behavior of power stages, different pulse width modulation (PWM) schemes and single-phase-to-earth fault detection are executed. Experiments to evaluate the electromagnetic interference (EMI) of possible inverter topologies on the AUG diagnostics are done as well. A special focus is put on the feasibility of analyzed topologies using industrially available and fully assembled “power modules” to minimize development effort and costs.

  4. Trends of chemical monitoring in power stations

    International Nuclear Information System (INIS)

    Winkler, R.; Venz, H.

    1983-01-01

    Frequently, the state-of-the-art of chemical monitoring in power plants is still determined by conservative methods. A thorough rationalization requires not only modern analytical procedures, but also the consideration of chemically affected processes in complex process analyses and the combination of automatic analyzers with available process computers. Using some examples, ways of reducing monitoring efforts without impairing safety and economy of nuclear power plant operation are pointed out. (author)

  5. Optimal power allocation of a sensor node under different rate constraints

    KAUST Repository

    Ayala Solares, Jose Roberto; Rezki, Zouheir; Alouini, Mohamed-Slim

    2012-01-01

    The optimal transmit power of a sensor node while satisfying different rate constraints is derived. First, an optimization problem with an instantaneous transmission rate constraint is addressed. Next, the optimal power is analyzed, but now

  6. Investment strategy for low-carbon power generation

    International Nuclear Information System (INIS)

    Yamasaki, Yukihiro; Matsuhashi, Ryuji; Yoshida, Yoshikuni

    2011-01-01

    Recently, it is needed to reduce CO 2 emissions for prevention of global warming. In Japan, the power generation sector is the biggest part in terms of CO 2 emissions, therefore it is very important to cope with the reduction of the emissions from this sector. From this point of view, it is assumed that the nuclear power generation is the most practical option to reduce them. In order to evaluate the possibility of introduction of the nuclear power, we built a generation planning model and simulate to analyze the transition of the optimal generation mix. Also, we evaluate the investment in the introduction of the nuclear power quantitatively using the real option analysis. (author)

  7. New small devices for radiation detection: the Wee Pocket Chirper and the Portable Multichannel Analyzer

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-08-01

    Recent events have demonstrated the need for improved capability to monitor the exposure of workers to radiation and, in general, to identify and measure the many forms of radioactive materials found throughout the nuclear industry. Two radiation monitoring devices have been developed that are much smaller than existing instruments, yet exhibit superior performance and a longer battery life. The first instrument, the Wee Pocket Chirper, is a tiny, battery-powered warning device that chirps when exposed to radiation. The second instrument is a portable battery-powered, computer-based, multichannel analyzer that allows the user to examine radiation fields and to identify the types and amounts of radioactive materials present

  8. Analyzing Capacity Withholding in Oligopoly Electricity Markets Considering Forward Contracts and Demand Elasticity

    Directory of Open Access Journals (Sweden)

    S. Salarkheili

    2011-12-01

    Full Text Available In this paper capacity withholding in an oligopolistic electricity market that all Generation Companies (GenCos bid in a Cournot model is analyzed and the capacity withheld index, the capacity distortion index and the price distortion index are obtained and formulated. Then a new index, Distortion-Withheld Index (DWI, is proposed in order to measure the potential ability of market for capacity withholding. In these indices the impact of demand elasticity on capacity withholding is considered and it is shown that demand elasticity plays an important role for capacity withholding and market power mitigation. Due to the significant role of forward contracts for market power mitigation and risk hedging in power markets, the impacts of these contracts on capacity withholding are considered. The effects of GenCos’ strategic forward contracts on capacity withholding are also discussed. Moreover, the relationship between capacity withholding of GenCos and market price distortion is acquired. A two-settlement market including a forward market and a spot market is used to describe GenCos’ strategic forward contracting and spot market competition.

  9. VAr reserve concept applied to a wind power plant

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Philip C.; Rodriguez, Pedro

    2011-01-01

    to wind power plants. This paper proposes two different VAr reserve control strategies for a wind power plant. The amount of dynamic VAr available most of the operation time, makes the wind power plant (WPP) a good candidate to include a VAr reserve management system. Two different ways of implementing...... a VAr management system are proposed and analyzed. Such a reactive power reserve may be provided by the wind power plant since the amount of reactive power installed for most active power working points exceeds the demand required by the grid operator. Basically, this overrated reactive power capacity...... is a consequence of sizing wind turbine facilities for maximum active power level. The reactive power losses, due to active power transportation inside the plant (normally two transformers), and P-Q wind turbine characteristics define the P-Q reserve chart. By utilizing the intrinsic overrated reactive power...

  10. Development of AC-DC power system simulator

    International Nuclear Information System (INIS)

    Ichikawa, Tatsumi; Ueda, Kiyotaka; Inoue, Toshio

    1984-01-01

    A modeling and realization technique is described for realtime plant dynamics simulation of nuclear power generating unit in AC-DC power system simulator. Dynamic behavior of reactor system and steam system is important for investigation a further adequate unit control and protection system to system faults in AC and DC power system. Each unit of two nuclear power generating unit in the power system simulator consists of micro generator, DC motors, flywheels and process computer. The DC motor and flywheel simulates dynamic characteristics of steam turbine, and process computer simulates plant dynamics by digital simulation. We have realized real-time plant dynamics simulation by utilizing a high speed process I/O and a high speed digital differential analyzing processor (DDA) in which we builted a newly developed simple plant model. (author)

  11. Design of dynamic power quality monitoring and fault diagnosis system of ship-power system based on Ethernet

    Directory of Open Access Journals (Sweden)

    HU Hongqian

    2018-02-01

    Full Text Available [Objectives] According to situation that the ship power information exchange system based on the traditional field bus has been unable to meet the needs of modern ship power system for informatization, automation, intelligent and safe operation. [Methods] This paper proposes the use of industrial Ethernet Modbus/TCP to make up for lack of field-bus. Then, the data center is established by collecting the inherent data of the field bus of the combined ship power system and collecting the real-time data from the online measurement device based on the Modbus/TCP. Correlation theory and neural network intelligent algorithm are used to analyze big data to complete the dynamic power quality monitoring and fault diagnosis of ship power system. [Results] Finally, the man-machine interface is designed with LabVIEW. [Conclusions] The feasibility of the software and hardware implementation of the scheme is verified by the laboratory platform.

  12. Computational methods in power system analysis

    CERN Document Server

    Idema, Reijer

    2014-01-01

    This book treats state-of-the-art computational methods for power flow studies and contingency analysis. In the first part the authors present the relevant computational methods and mathematical concepts. In the second part, power flow and contingency analysis are treated. Furthermore, traditional methods to solve such problems are compared to modern solvers, developed using the knowledge of the first part of the book. Finally, these solvers are analyzed both theoretically and experimentally, clearly showing the benefits of the modern approach.

  13. Cause trending analysis for licensing operational events in Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Wang Dewei

    2005-01-01

    The human causal factors for all human error licensing operational events on Daya Bay nuclear power station since 1993 to 2003 are categorized, the trend of these causal factors is analyzed. The emphasis is placed on analyzing the deficiencies on complying with and executing regulations and procedures. The results provide directional reference for nuclear power station to improve human performance. (author)

  14. Value and power in economics

    Directory of Open Access Journals (Sweden)

    Josifidis Kosta

    2012-01-01

    Full Text Available In this article we rethink the field of value in economic theory. First, we prove that the transhistorical and nominalist approaches show different weaknesses and can not account for the constitutive dimensions of value. Within this context, we demonstrate why value emerged in the first place and what epistemological dimensions it provided and enabled for economic reflexivity. In addition, we demonstrate that it is impossible to understand inherent value as an immanent property of goods in economic transactions and we critique the approach that renders value to the theory of price. Economic relations reflect value-related aspects without which the relations could not be understood. We then analyze the interrelations between power and value, proving the constitutive dimension of power in understanding value, demonstrated in selected examples. We treat power as a constellation in which economic agents act on other subjects to provoke certain activity. Power may occur only where the behaviour of subjects is not entirely determined. Finally, one additional selected example shows the range of this theory of power in terms of positional goods.

  15. Nuclear power: the fifth horseman

    International Nuclear Information System (INIS)

    Hayes, D.

    1976-01-01

    ''Nuclear Power: The Fifth Horseman,'' is published in an attempt to identify and analyze emerging global trends and problems. This paper evaluates the future of nuclear power, subjecting it to several tests--those of economics, safety, adequacy of fuel supplies, environmental impact, and both national and international security. If the world is to ''go nuclear,'' adopting nuclear power as the principal source of energy, each of these criteria should be satisfied. In fact, none may be satisfied. Nuclear power is being re-examined in many quarters. Local communities throughout the world are concerned over reactor safety. Environmentalists and others are deeply concerned about the lack, or even the prospect, of satisfactory techniques for disposing of radioactive waste. Foreign policy analysts express grave concern over the weapons-proliferation implications of the spread of nuclear power, recognizing that sooner or later an unstable political leader or terrorist group will acquire this awesome weaponry. And, in 1975, the corporate executives who head electrical utilities in the United States cancelled or deferred 25 times as many new reactors as they ordered

  16. Probabilistic Forecast of Wind Power Generation by Stochastic Differential Equation Models

    KAUST Repository

    Elkantassi, Soumaya

    2017-01-01

    Reliable forecasting of wind power generation is crucial to optimal control of costs in generation of electricity with respect to the electricity demand. Here, we propose and analyze stochastic wind power forecast models described by parametrized

  17. Investments in liberalised power markets

    International Nuclear Information System (INIS)

    Grenaa Jensen, S.; Meibom, P.

    2005-01-01

    There is considerable uncertainty in the Nordic electricity system with respect to the long-term development in production capacity. The process towards liberalisation of the electricity sector started with a situation of a large capacity margin, but this margin is gradually vanishing. Since the potential investors in new production capacity are unaccustomed with investments under the new regime, it is unknown if and when investments will take place. The purpose of the present study is to analyze if and when investors choose to invest in new electricity production capacity depending on their existing portfolio of power producing units. Electricity price scenarios generated with a partial equilibrium model (Balmorel) are combined with a model of investment decisions. In this, various scenarios concerning the development in the Nordic power market, such as new transmission lines between neighbouring countries, more installed wind power, and changes in CO 2 emission trading costs, are used to investigate the consequences for investments in a natural gas fired, combined cycle power plant. The main result of the analysis is that new investments are highly sensitive to investors existing power production portfolio, as new production units affect the merit order in the power market, i.e. compete with the existing power plants. (au)

  18. Thromboelastography platelet mapping in healthy dogs using 1 analyzer versus 2 analyzers.

    Science.gov (United States)

    Blois, Shauna L; Banerjee, Amrita; Wood, R Darren; Park, Fiona M

    2013-07-01

    The objective of this study was to describe the results of thromboelastography platelet mapping (TEG-PM) carried out using 2 techniques in 20 healthy dogs. Maximum amplitudes (MA) generated by thrombin (MAthrombin), fibrin (MAfibrin), adenosine diphosphate (ADP) receptor activity (MAADP), and thromboxane A2 (TxA2) receptor activity (stimulated by arachidonic acid, MAAA) were recorded. Thromboelastography platelet mapping was carried out according to the manufacturer's guidelines (2-analyzer technique) and using a variation of this method employing only 1 analyzer (1-analyzer technique) on 2 separate blood samples obtained from each dog. Mean [± standard deviation (SD)] MA values for the 1-analyzer/2-analyzer techniques were: MAthrombin = 51.9 mm (± 7.1)/52.5 mm (± 8.0); MAfibrin = 20.7 mm (± 21.8)/23.0 mm (± 26.1); MAADP = 44.5 mm (± 15.6)/45.6 mm (± 17.0); and MAAA = 45.7 mm (± 11.6)/45.0 mm (± 15.4). Mean (± SD) percentage aggregation due to ADP receptor activity was 70.4% (± 32.8)/67.6% (± 33.7). Mean percentage aggregation due to TxA2 receptor activity was 77.3% (± 31.6)/78.1% (± 50.2). Results of TEG-PM were not significantly different for the 1-analyzer and 2-analyzer methods. High correlation was found between the 2 methods for MAfibrin [concordance correlation coefficient (r) = 0.930]; moderate correlation was found for MAthrombin (r = 0.70) and MAADP (r = 0.57); correlation between the 2 methods for MAAA was lower (r = 0.32). Thromboelastography platelet mapping (TEG-PM) should be further investigated to determine if it is a suitable method for measuring platelet dysfunction in dogs with thrombopathy.

  19. Impacts of Large Amounts of Wind Power on Design and Operation of Power Systems; Results of IEA Collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ela, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Holttinen, H. [VTT (Finland); Meibom, P. [DTU Riso (Denmark); Orths, A. [Energinet.dk (Denmark); O' Malley, M. [Univ. College Dubline (Ireland); Ummels, B. C. [Delft Univ. of Technology (Netherlands); Tande, J. [SINTEF (Norway); Estanqueiro, A. [INETI (Portugal); Gomez, E. [Univ. Castilla la Mancha (Spain); Smith, J. C. [Utility Wind Integration Group (UWIG), Reston, VA (United States)

    2008-06-01

    There are a multitude of studies completed and ongoing related to the cost of wind integration. However, the results are not easy to compare. An international forum for exchange of knowledge of power system impacts of wind power has been formed under the IEA Implementing Agreement on Wind Energy. IEA WIND R&D Task 25 on “Design and Operation of Power Systems with Large Amounts of Wind Power” produced a state-of-the-art report in October 2007, where the most relevant wind-power grid integration studies were analyzed, especially regarding methodologies and input data. This paper summarizes the results from 18 case studies, with discussion on differences in methodology as well as issues that have been identified to impact the cost of wind integration.

  20. Power Electronic Drives, Controls, and Electric Generators for Large Wind Turbines - An Overview

    DEFF Research Database (Denmark)

    Ma, Ke; Tutelea, L.; Boldea, Ion

    2015-01-01

    and exceed a power rating of 10 MW are discussed. The role of power electronics for improving the operation of wind turbines and ensuring compliance with power grid codes is analyzed with a view at producing fully controllable generation units suitable for tight integration into the power grid and large...

  1. Self-oscillating modulators for direct energy conversion audio power amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    Direct energy conversion audio power amplifier represents total integration of switching-mode power supply and Class D audio power amplifier into one compact stage, achieving high efficiency, high level of integration, low component count and eventually low cost. This paper presents how self-oscillating modulators can be used with the direct switching-mode audio power amplifier to improve its performance by providing fast hysteretic control with high power supply rejection ratio, open-loop stability and high bandwidth. Its operation is thoroughly analyzed and simulated waveforms of a prototype amplifier are presented. (au)

  2. Engineering schedule control of nuclear power project planning and management

    International Nuclear Information System (INIS)

    Meng Hao

    2014-01-01

    Nuclear power design is the important part of project management of nuclear power project, it is the way to control the project organization, design schedule, design progress, design quality and cost control. The good schedule system and control is the key to the success for the project. It is also analyzed the problem during the project, by using some theory and analyze the project structure, design schedule management, IED and document management and interface management propose some new idea for better improve the design management to finally better improve the management quality and efficiency. (author)

  3. Study of Power Options for Jupiter and Outer Planet Missions

    Science.gov (United States)

    Landis, Geoffrey A.; Fincannon, James

    2015-01-01

    Power for missions to Jupiter and beyond presents a challenging goal for photovoltaic power systems, but NASA missions including Juno and the upcoming Europa Clipper mission have shown that it is possible to operate solar arrays at Jupiter. This work analyzes photovoltaic technologies for use in Jupiter and outer planet missions, including both conventional arrays, as well as analyzing the advantages of advanced solar cells, concentrator arrays, and thin film technologies. Index Terms - space exploration, spacecraft solar arrays, solar electric propulsion, photovoltaic cells, concentrator, Fresnel lens, Jupiter missions, outer planets.

  4. APR1400 CEA Withdrawal at Power Accident Analysis using KNAP

    International Nuclear Information System (INIS)

    Lee, Dong-Hyuk; Yang, Chang-Keun; Kim, Yo-Han; Sung, Chang-Kyung

    2006-01-01

    KEPRI (Korea Electric Power Research Institute) has been developing safety analysis methodology for non- LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code. RETRAN code is a non- LOCA safety analysis code developed by EPRI. The new methodology will replace existing CE (Combustion Engineering) supplied codes and methodologies currently used in non-LOCA analysis of OPR1000. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400). The CEA (Control Element Assembly) withdrawal at power accident is one of the 'reactivity and power distribution anomalies' events and the results are typically described in the chapter 15.4.2 of SAR (Safety Analysis Report). The APR1400 has been designed to generate 1,400MWe of electricity with advanced features for greatly enhanced safety and economic goals. The CEA withdrawal at power analysis in APR1400 SSAR (Standard Safety Analysis Report) is analyzed with CESEC-III computer code. In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, CEA withdrawal at power accident is analyzed using RETRAN code and it is compared with results from APR1400 SSAR

  5. GROUNDING THE REDUCTION OF POWER OF THE HYDRAULIC DRIVE ELECTRIC MOTOR BY EQUIVALENT POWER METHOD

    Directory of Open Access Journals (Sweden)

    O. Hrygorov

    2017-06-01

    Full Text Available The authors have analyzed the power consumption by a hydraulic drive and wound rotor motor of crane mechanisms at all stages of the operational cycle: acceleration, movement at nominal or intermediate speed and deceleration. The decrease of the rated capacity of electric motors is justified.

  6. Relativistic effects in the calibration of electrostatic electron analyzers. I. Toroidal analyzers

    Energy Technology Data Exchange (ETDEWEB)

    Keski Rahkonen, O [Helsinki University of Technology, Espoo (Finland). Laboratory of Physics; Krause, M O [Oak Ridge National Lab., Tenn. (USA)

    1978-02-01

    Relativistic correction terms up to the second order are derived for the kinetic energy of an electron travelling along the circular central trajectory of a toroidal analyzer. Furthermore, a practical energy calibration equation of the spherical sector plate analyzer is written for the variable-plate-voltage recording mode. Accurate measurements with a spherical analyzer performed using kinetic energies from 600 to 2100 eV are in good agreement with this theory showing our approximation (neglect of fringing fields, and source and detector geometry) is realistic enough for actual calibration purposes.

  7. A pragmatic study of speech as an instrument of power: Analysis of the 2016 USA presidential debate

    Directory of Open Access Journals (Sweden)

    Misyi Gusthini

    2018-03-01

    Full Text Available This research was aimed at analyzing the speeches of Donald Trump and of Hillary Clinton in the USA Presidential candidates’ debates as instruments of power. The data is a presidential final debate video of Trump and Clinton made in September 2016 which has been converted into a transcript. The data analyzing technique is divided into three steps: 1 describing the context, 2 analyzing the illocutionary acts, and 3 analyzing the power dimensions. The results of this research show that the speakers use the speech act as an instrument of power with classifications of representative, commissive and expressive. In this regard, the researchers found that the speakers demonstrated their power to try to convince the voters in their society to trust them to be the president. The research results also showed that the usage of speech in debate as an instrument of power can influence the voters especially on Election Day.

  8. Operational safety performance and economical efficiency evaluation for nuclear power plants

    International Nuclear Information System (INIS)

    Liu Yachun; Zou Shuliang

    2012-01-01

    The economical efficiency of nuclear power includes a series of environmental parameters, for example, cleanliness. Nuclear security is the precondition and guarantee for its economy, and both are the direct embodiment of the social benefits of nuclear power. Through analyzing the supervision and management system on the effective operation of nuclear power plants, which has been put forward by the International Atomic Energy Agency (IAEA), the World Association of Nuclear Operators (WANO), the U.S. Nuclear Regulatory Commission (NRC), and other organizations, a set of indexs on the safety performance and economical efficiency of nuclear power are explored and established; Based on data envelopment analysis, a DEA approach is employed to evaluate the efficiency of the operation performance of several nuclear power plants, Some primary conclusion are achieved on the basis of analyzing the threshold parameter's sensitivity and relativity which affected operational performance. To address the conflicts between certain security and economical indicators, a multi-objective programming model is established, where top priority is given to nuclear safety, and the investment behavior of nuclear power plant is thereby optimized. (authors)

  9. Modeling generator power plant portfolios and pollution taxes in electric power supply chain networks: a transportation network equilibrium transformation

    International Nuclear Information System (INIS)

    Kai Wu; Nagurney, A.; University of Massachusetts, Amherst, MA; Zugang Liu; Stranlund, J.K.

    2006-01-01

    Global climate change and fuel security risks have encouraged international and regional adoption of pollution/carbon taxes. A major portion of such policy interventions is directed at the electric power industry with taxes applied according to the type of fuel used by the power generators in their power plants. This paper proposes an electric power supply chain network model that captures the behavior of power generators faced with a portfolio of power plant options and subject to pollution taxes. We demonstrate that this general model can be reformulated as a transportation network equilibrium model with elastic demands and qualitatively analyzed and solved as such. The connections between these two different modeling schemas is done through finite-dimensional variational inequality theory. The numerical examples illustrate how changes in the pollution/carbon taxes affect the equilibrium electric power supply chain network production outputs, the transactions between the various decision-makers the demand market prices, as well as the total amount of carbon emissions generated. (author)

  10. Towards a more efficient energy use in photovoltaic powered products

    NARCIS (Netherlands)

    Kan, S.Y.; Strijk, R.

    2006-01-01

    This paper analyzes the energy saving and power management solutions necessary to improve the energy consumption efficiency in photovoltaic powered products. Important in the design of such products is not only the energy supply optimization required to deliver the actual energy to fulfil their

  11. AlGaN/GaN-HEMT power amplifiers with optimized power-added efficiency for X-band applications

    OpenAIRE

    Kühn, J.

    2011-01-01

    This work has arisen out of the strong demand for a superior power-added efficiency (PAE) of AlGaN/GaN high electron mobility transistor (HEMT) high-power amplifiers (HPAs) that are part of any advanced wireless multifunctional RF-system with limited prime energy. Different concepts and approaches on device and design level for PAE improvements are analyzed, e.g. structural and layout changes of the GaN transistor and advanced circuit design techniques for PAE improvements of GaN HEMT HPAs.

  12. Multichannel analyzer development in CAMAC

    International Nuclear Information System (INIS)

    Nagy, J.Z.; Zarandy, A.

    1988-01-01

    The data acquisition in TOKAMAK experiments some CAMAC modules have been developed. The modules are the following: 64 K analyzer memory, 32 K analyzer memory, 6-channel pulse peak analyzer memory which contains the 32 K analyzer memory and eight AD-converters

  13. Energy-Efficient Power Allocation for MIMO-SVD Systems

    KAUST Repository

    Sboui, Lokman

    2017-05-24

    In this paper, we address the problem of energyefficient power allocation in MIMO systems. In fact, the widely adopted water-filling power allocation does not ensure the maximization of the energy efficiency (EE). Since the EE maximization is a non-convex problem, numerical methods based on fractional programming were introduced to find the optimal power solutions. In this paper, we present a novel and simple power allocation scheme based on the explicit expressions of the optimal power. We also present a low-complexity algorithm that complements the proposed scheme for low circuit-power regime. Furthermore, we analyze power-constrained and rate-constrained systems and present the corresponding optimal power control. In the numerical results, we show that the presented analytical expressions are accurate and that the algorithm converges within two iterations. We also show that as the number of antenna increases, the system becomes more energy-efficient. Also, a saturation of the EE is observed at high power budget and low minimal rate regimes.

  14. Nuclear power and ratepayer protest: The Washington Public Power Supply System crisis

    International Nuclear Information System (INIS)

    Sugai, W.H.

    1986-01-01

    In early 1982, the Washington Public Power Supply System (WPPSS) terminated two nuclear projects, triggering an episode of mass ratepayer insurgency throughout the state. In this survey of the crisis, the author analyzes the political and economic conditions that precipitated the protest and examines citizen opposition to the WPPSS nuclear venture between 1976 and 1981. The review of the public initiative campaigns aimed at the Northwest utility establishment by local antinuclear forces and the role of key individuals and organizations involved in anti-KPPSS activism are central to the discussion. By emphasizing the organizational dynamics of citizen opposition, the analysis clarifies the influence of antinuclear protest in bringing about the WPPSS crisis, which is still in litigation over disputed financial and management liability claims. Finally, the author offers insights into the implications of the 1980 Pacific Northwest Electric Power Planning and Conservation Act and the role of the new Northwest Power Planning Council in regional electrical energy planning

  15. Quasi-Optical Network Analyzers and High-Reliability RF MEMS Switched Capacitors

    Science.gov (United States)

    Grichener, Alexander

    The thesis first presents a 2-port quasi-optical scalar network analyzer consisting of a transmitter and receiver both built in planar technology. The network analyzer is based on a Schottky-diode mixer integrated inside a planar antenna and fed differentially by a CPW transmission line. The antenna is placed on an extended hemispherical high-resistivity silicon substrate lens. The LO signal is swept from 3-5 GHz and high-order harmonic mixing in both up- and down- conversion mode is used to realize the 15-50 GHz RF bandwidth. The network analyzer resulted in a dynamic range of greater than 40 dB and was successfully used to measure a frequency selective surface with a second-order bandpass response. Furthermore, the system was built with circuits and components for easy scaling to millimeter-wave frequencies which is the primary motivation for this work. The application areas for a millimeter and submillimeter-wave network analyzer include material characterization and art diagnostics. The second project presents several RF MEMS switched capacitors designed for high-reliability operation and suitable for tunable filters and reconfigurable networks. The first switched-capacitor resulted in a digital capacitance ratio of 5 and an analog capacitance ratio of 5-9. The analog tuning of the down-state capacitance is enhanced by a positive vertical stress gradient in the the beam, making it ideal for applications that require precision tuning. A thick electroplated beam resulted in Q greater than 100 at C to X-band frequencies, and power handling of 0.6-1.1 W. The design also minimized charging in the dielectric, resulting in excellent reliability performance even under hot-switched and high power (1 W) conditions. The second switched-capacitor was designed without any dielectric to minimize charging. The device was hot-switched at 1 W of RF power for greater than 11 billion cycles with virtually no change in the C-V curve. The final project presents a 7-channel

  16. Control strategy research of two stage topology for pulsed power supply

    International Nuclear Information System (INIS)

    Shi Chunfeng; Wang Rongkun; Huang Yuzhen; Chen Youxin; Yan Hongbin; Gao Daqing

    2013-01-01

    A kind of pulsed power supply of HIRFL-CSR was introduced, the ripple and the current error of the topological structure of the power in the operation process were analyzed, and two stage topology of pulsed power supply was given. The control strategy was simulated and the experiment was done in digital power platform. The results show that the main circuit structure and control method are feasible. (authors)

  17. An Optimal Reactive Power Control Strategy for a DFIG-Based Wind Farm to Damp the Sub-Synchronous Oscillation of a Power System

    Directory of Open Access Journals (Sweden)

    Bin Zhao

    2014-05-01

    Full Text Available This study presents the auxiliary damping control with the reactive power loop on the rotor-side converter of doubly-fed induction generator (DFIG-based wind farms to depress the sub-synchronous resonance oscillations in nearby turbogenerators. These generators are connected to a series capacitive compensation transmission system. First, the damping effect of the reactive power control of the DFIG-based wind farms was theoretically analyzed, and a transfer function between turbogenerator speed and the output reactive power of the wind farms was introduced to derive the analytical expression of the damping coefficient. The phase range to obtain positive damping was determined. Second, the PID phase compensation parameters of the auxiliary damping controller were optimized by a genetic algorithm to obtain the optimum damping in the entire subsynchronous frequency band. Finally, the validity and effectiveness of the proposed auxiliary damping control were demonstrated on a modified version of the IEEE first benchmark model by time domain simulation analysis with the use of DigSILENT/PowerFactory. Theoretical analysis and simulation results show that this derived damping factor expression and the condition of the positive damping can effectively analyze their impact on the system sub-synchronous oscillations, the proposed wind farms reactive power additional damping control strategy can provide the optimal damping effect over the whole sub-synchronous frequency band, and the control effect is better than the active power additional damping control strategy based on the power system stabilizator.

  18. Nuclear plant analyzer: An efficient tool for training and operational analyses

    International Nuclear Information System (INIS)

    Bartsoen, L.; Mandy, C.; Stubbe, E.

    1999-01-01

    The advanced computer technology available now at low cost, combined with the maturity of the best-estimate engineering codes are the fundamentals of the Nuclear Plant Analyzer (NPA). At Tractebel Energy Engineering (TEE), the RELAP5 advanced thermal-hydraulics code is used as basis for the NPA that is mainly used for the training of simulator instructors and plant personnel. Using the special graphical features of the NPA, a set of six course modules has been prepared to provide an in-depth physical understanding of the main thermal-hydraulic phenomena that dominate nuclear power plant behavior in normal and accidental plant conditions. (author)

  19. Power distribution changes caused by subcooled nucleate boiling at Callaway Nuclear Power Plant

    International Nuclear Information System (INIS)

    Konya, M.J.; Bryant, K.R.; Hopkins, D.L.

    1993-01-01

    This paper reports the results of an evaluation undertaken by Union Electric (UE) and Westinghouse to explain anomalous behavior of the core axial power distribution at the Callaway Nuclear Power Plant. The behavior was characterized by a gradual unexpected power shift toward the bottom of the core and was first detected during cycle 4 at a core average burnup of approximately 7,000 MWD/MTU. Once started, the power shift continued until burnup effects became dominant and caused power to shift back to the top of the core at the end of the cycle. In addition to the anomalous power distribution, UE observed that estimated critical control rod position (ECP) deviations increased to over 500 pcm (0.5%Δk/k) during Cycles 4 and 5. ECPs for plant restarts that occurred early in each cycle agreed well with measured critical conditions. However, this agreement disappeared for restarts that occurred later in core life. After analyzing relevant data, performing scoping calculations and reviewing industry experience, the authors concluded that the power distribution anomaly was most likely caused by subcooled nucleate boiling. Crud deposition on the fuel was believed to enhance the subcooled boiling. The ECP deviations were a secondary effect of the power shift, since void fraction, axial burnup and xenon distributions departed design predictions during a substantial portion of the fuel cycles. Significant evidence supporting these conclusions include incore detector indications of flux depressions between intermediate flow mixing (IFM) and structural grids. In addition, visual exam results show the presence of crud deposits on fuel pins

  20. Web server attack analyzer

    OpenAIRE

    Mižišin, Michal

    2013-01-01

    Web server attack analyzer - Abstract The goal of this work was to create prototype of analyzer of injection flaws attacks on web server. Proposed solution combines capabilities of web application firewall and web server log analyzer. Analysis is based on configurable signatures defined by regular expressions. This paper begins with summary of web attacks, followed by detection techniques analysis on web servers, description and justification of selected implementation. In the end are charact...