WorldWideScience

Sample records for analysis including plasma

  1. Partially ionized plasmas including the third symposium on uranium plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, M. [ed.

    1976-09-01

    Separate abstracts are included for 28 papers on electrically generated plasmas, fission generated plasmas, nuclear pumped lasers, gaseous fuel reactor research, and applications. Five papers have been previously abstracted and included in ERA.

  2. Electrode assemblies, plasma apparatuses and systems including electrode assemblies, and methods for generating plasma

    Science.gov (United States)

    Kong, Peter C; Grandy, Jon D; Detering, Brent A; Zuck, Larry D

    2013-09-17

    Electrode assemblies for plasma reactors include a structure or device for constraining an arc endpoint to a selected area or region on an electrode. In some embodiments, the structure or device may comprise one or more insulating members covering a portion of an electrode. In additional embodiments, the structure or device may provide a magnetic field configured to control a location of an arc endpoint on the electrode. Plasma generating modules, apparatus, and systems include such electrode assemblies. Methods for generating a plasma include covering at least a portion of a surface of an electrode with an electrically insulating member to constrain a location of an arc endpoint on the electrode. Additional methods for generating a plasma include generating a magnetic field to constrain a location of an arc endpoint on an electrode.

  3. Plasma Cell Neoplasms (Including Multiple Myeloma)—Health Professional Version

    Science.gov (United States)

    There are several types of plasma cell neoplasms, including monoclonal gammopathy of undetermined significance (MGUS), isolated plasmacytoma of the bone, extramedullary plasmacytoma, and multiple myeloma. Find evidence-based information on plasma cell neoplasms treatment, research, and statistics.

  4. CHAPTER 7. BERYLLIUM ANALYSIS BY NON-PLASMA BASED METHODS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-04-20

    The most common method of analysis for beryllium is inductively coupled plasma atomic emission spectrometry (ICP-AES). This method, along with inductively coupled plasma mass spectrometry (ICP-MS), is discussed in Chapter 6. However, other methods exist and have been used for different applications. These methods include spectroscopic, chromatographic, colorimetric, and electrochemical. This chapter provides an overview of beryllium analysis methods other than plasma spectrometry (inductively coupled plasma atomic emission spectrometry or mass spectrometry). The basic methods, detection limits and interferences are described. Specific applications from the literature are also presented.

  5. Including plasma and fusion topics in the science education in school

    International Nuclear Information System (INIS)

    Kado, Shinichiro

    2015-01-01

    Yutori education (more relaxed education policy) started with the revision of the Courses of Study to introduce 'five-day week system' in 1989, continued with the reduction of the content of school lessons by 30% in 1998, and ended with the introduction of the New Courses of Study in 2011. Focusing on science education, especially in the topics of plasma and nuclear fusion, the modality of the education system in Japan is discussed considering the transition of academic performance based on the Program for International Student Assessment (PISA) in comparison with the examples in other countries. Particularly, the issues with high school textbooks are pointed out from the assessment of current textbooks, and the significance and the need for including the topic of 'plasma' in them are stated. Lastly, in order to make the general public acknowledged with plasma and nuclear fusion, it is suggested to include them also in junior high school textbooks, by briefly mentioning the terms related to plasma, solar wind, aurora phenomenon, and nuclear fusion energy. (S.K.)

  6. 77 FR 6463 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma...

    Science.gov (United States)

    2012-02-08

    ... Blood Components, Including Source Plasma; Correction AGENCY: Food and Drug Administration, HHS. ACTION..., Including Source Plasma,'' which provided incorrect publication information regarding a 60-day notice that...

  7. Analysis of plasma behavior and electro-magnetic interaction between plasma and device

    International Nuclear Information System (INIS)

    Kobayashi, Tomofumi

    1980-01-01

    A simulation program for the analysis of plasma behavior and the electromagnetic interaction between plasma and device has been developed. The program consists of a part for the analysis of plasma behavior (plasma system) and a part for the analysis of the electro-magnetic interaction between plasma and devices (circuit system). The parameters which connect the plasma system and the circuit system are the electric resistance of plasma, the internal inductance, and the plasma current. For the plasma system, the simultaneous equations which describe the density distribution of plasma particles, the temperature distribution of electrons and ions, and the space-time variation of current density distribution were derived. The one-dimensional plasma column in γ-direction was considered. The electric resistance and the internal inductance can be deduced. The circuit components are a current transformer, a vertical field coil, a quadrupole field coil, a vacuum chamber and others. An equation which describes plasma position and the shape of cross section is introduced. The plasma position can be known by solving the Mukhavatov's formula of equilibrium. By using this program, the build-up process of plasma current in JT-60 was analysed. It was found that the expansion of plasma sub radius and the control of current distribution by gas injection are the effective methods to obtain high temperature and high density plasma. The eddy current induced in a vacuum vessel shields 40 percent of magnetic field made in the plasma region by a vertical field coil. (Kato, T.)

  8. Laser-induced plasmas as an analytical source for quantitative analysis of gaseous and aerosol systems: Fundamentals of plasma-particle interactions

    Science.gov (United States)

    Diwakar, Prasoon K.

    2009-11-01

    Laser-induced Breakdown Spectroscopy (LIBS) is a relatively new analytical diagnostic technique which has gained serious attention in recent past due to its simplicity, robustness, and portability and multi-element analysis capabilities. LIBS has been used successfully for analysis of elements in different media including solids, liquids and gases. Since 1963, when the first breakdown study was reported, to 1983, when the first LIBS experiments were reported, the technique has come a long way, but the majority of fundamental understanding of the processes that occur has taken place in last few years, which has propelled LIBS in the direction of being a well established analytical technique. This study, which mostly focuses on LIBS involving aerosols, has been able to unravel some of the mysteries and provide knowledge that will be valuable to LIBS community as a whole. LIBS processes can be broken down to three basic steps, namely, plasma formation, analyte introduction, and plasma-analyte interactions. In this study, these three steps have been investigated in laser-induced plasma, focusing mainly on the plasma-particle interactions. Understanding plasma-particle interactions and the fundamental processes involved is important in advancing laser-induced breakdown spectroscopy as a reliable and accurate analytical technique. Critical understanding of plasma-particle interactions includes study of the plasma evolution, analyte atomization, and the particle dissociation and diffusion. In this dissertation, temporal and spatial studies have been done to understand the fundamentals of the LIBS processes including the breakdown of gases by the laser pulse, plasma inception mechanisms, plasma evolution, analyte introduction and plasma-particle interactions and their influence on LIBS signal. Spectral measurements were performed in a laser-induced plasma and the results reveal localized perturbations in the plasma properties in the vicinity of the analyte species, for

  9. Plasma Cell Neoplasms (Including Multiple Myeloma)—Patient Version

    Science.gov (United States)

    Plasma cell neoplasms occur when abnormal plasma cells form cancerous tumors. When there is only one tumor, the disease is called a plasmacytoma. When there are multiple tumors, it is called multiple myeloma. Start here to find information on plasma cell neoplasms treatment, research, and statistics.

  10. MHD stability analysis of helical system plasmas

    International Nuclear Information System (INIS)

    Nakamura, Yuji

    2000-01-01

    Several topics of the MHD stability studies in helical system plasmas are reviewed with respect to the linear and ideal modes mainly. Difference of the method of the MHD stability analysis in helical system plasmas from that in tokamak plasmas is emphasized. Lack of the cyclic (symmetric) coordinate makes an analysis more difficult. Recent topic about TAE modes in a helical system is also described briefly. (author)

  11. Toward the automated analysis of plasma physics problems

    International Nuclear Information System (INIS)

    Mynick, H.E.

    1989-04-01

    A program (CALC) is described, which carries out nontrivial plasma physics calculations, in a manner intended to emulate the approach of a human theorist. This includes the initial process of gathering the relevant equations from a plasma knowledge base, and then determining how to solve them. Solution of the sets of equations governing physics problems, which in general have a nonuniform,irregular structure, not amenable to solution by standardized algorithmic procedures, is facilitated by an analysis of the structure of the equations and the relations among them. This often permits decompositions of the full problem into subproblems, and other simplifications in form, which renders the resultant subsystems soluble by more standardized tools. CALC's operation is illustrated by a detailed description of its treatment of a sample plasma calculation. 5 refs., 3 figs

  12. Dispersion in thermal plasma including arbitrary degeneracy and quantum recoil

    International Nuclear Information System (INIS)

    Mushtaq, A.; Melrose, D.B.

    2012-01-01

    The longitudinal response function for a thermal electron gas was calculated including two quantum effects exactly, degeneracy and the quantum recoil. The Fermi-Dirac distribution was expanded in powers of a parameter that is small in the non-degenerate limit and the response function was evaluated in terms of the conventional plasma dispersion function to arbitrary order in this parameter. The infinite sum was performed in terms of poly logarithms in the long-wavelength and quasi-static limits, giving results that apply for arbitrary degeneracy. The results were applied to the dispersion relations for Langmuir waves and to screening, reproducing known results in the non-degenerate and completely degenerate limits], and generalizing them to arbitrary degeneracy. The occupation number for the completely degenerate limit is shown. The importance of the results regarding to semiconductor plasmas were highlighted. (orig./A.B.)

  13. Plasma chromatography

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This book examines the fundamental theory and various applications of ion mobility spectroscopy. Plasma chromatography developed from research on the diffusion and mobility of ions. Topics considered include instrument design and description (e.g., performance, spectral interpretation, sample handling, mass spectrometry), the role of ion mobility in plasma chromatography (e.g., kinetic theory of ion transport), atmospheric pressure ionization (e.g., rate equations), the characterization of isomers by plasma chromatography (e.g., molecular ion characteristics, polynuclear aromatics), plasma chromatography as a gas chromatographic detection method (e.g., qualitative analysis, continuous mobility monitoring, quantitative analysis), the analysis of toxic vapors by plasma chromatography (e.g., plasma chromatograph calibration, instrument control and data processing), the analysis of semiconductor devices and microelectronic packages by plasma chromatography/mass spectroscopy (e.g., analysis of organic surface contaminants, analysis of water in sealed electronic packages), and instrument design and automation (hardware, software)

  14. Structural Analysis of Extended Plasma Focus Chamber

    International Nuclear Information System (INIS)

    Mohd Azhar Ahmad; Abdul Halim Baijan; Siti Aiasah Hashim

    2016-01-01

    Accelerator Development Centre (ADC) of Nuclear Malaysia intends to upgrade the plasma focus device. It involves the extension part placed on top of the existing plasma focus vacuum chamber. This extended vacuum chamber purposely to give an extra space in conducting experiments on the existing plasma focus chamber. The aim of upgrading the plasma focus device is to solve the limitation in research and analysis of sample due to its done in an open system that cause analysis of samples is limited and less optimal. This extended chamber was design in considering the ease of fabrication as well as durability of its structural. Thus, this paper discusses the structural analysis in term of pressure loading effect in extended chamber. (author)

  15. Analysis of human blood plasma proteome from ten healthy volunteers from Indian population.

    Directory of Open Access Journals (Sweden)

    Poonam Gautam

    Full Text Available Analysis of any mammalian plasma proteome is a challenge, particularly by mass spectrometry, due to the presence of albumin and other abundant proteins which can mask the detection of low abundant proteins. As detection of human plasma proteins is valuable in diagnostics, exploring various workflows with minimal fractionation prior to mass spectral analysis, is required in order to study population diversity involving analysis in a large cohort of samples. Here, we used 'reference plasma sample', a pool of plasma from 10 healthy individuals from Indian population in the age group of 25-60 yrs including 5 males and 5 females. The 14 abundant proteins were immunodepleted from plasma and then evaluated by three different workflows for proteome analysis using a nanoflow reverse phase liquid chromatography system coupled to a LTQ Orbitrap Velos mass spectrometer. The analysis of reference plasma sample a without prefractionation, b after prefractionation at peptide level by strong cation exchange chromatography and c after prefractionation at protein level by sodium dodecyl sulfate polyacrylamide gel electrophoresis, led to the identification of 194, 251 and 342 proteins respectively. Together, a comprehensive dataset of 517 unique proteins was achieved from all the three workflows, including 271 proteins with high confidence identified by ≥ 2 unique peptides in any of the workflows or identified by single peptide in any of the two workflows. A total of 70 proteins were common in all the three workflows. Some of the proteins were unique to our study and could be specific to Indian population. The high-confidence dataset obtained from our study may be useful for studying the population diversity, in discovery and validation process for biomarker identification.

  16. Tools for spectral data analysis of arbitrary emitters in edge plasma

    International Nuclear Information System (INIS)

    Marandet, Y.; Genesio, P.; Godbert-Mouret, L.; Koubiti, M.; Stamm, R.; Felts, B.; Capes, H.; Guirlet, R.; Lotte, P.; Lowry, C.

    2003-01-01

    A line shape code including Stark, Zeeman and Doppler effects has been upgraded to include atomic fine structure effects and the motional Stark effect (MST). Genetic algorithms provide an efficient and robust tool for automated analysis of edge plasma line shapes. Such an algorithm has been used to fit Doppler-broadened Zeeman D α /H α spectra observed in Tore-Supra. Spectra were analyzed from 2 different machine configurations, corresponding to: 1) recycling from the ergodic divertor (ED), with lines of sight tangential to the magnetic field; 2) recycling at the toroidal pump limiter (TPL) with vertical lines of sight perpendicular to the magnetic field. Preliminary results indicate that the plasma above the TPL contains a larger fraction of warm particles than the ED plasma. (A.C.)

  17. Nonlinear evolution of a three dimensional longitudinal plasma wavepacket in a hot plasma including the effect of its interaction with an ion-acoustic wave

    International Nuclear Information System (INIS)

    Das, K.P.; Sihi, S.

    1979-01-01

    Assuming amplitudes as slowly varying functions of space and time and using perturbation method three coupled nonlinear partial differential equations are obtained for the nonlinear evolution of a three dimensional longitudinal plasma wave packet in a hot plasma including the effect of its interaction with a long wavelength ion-acoustic wave. These three equations are used to derive the instability conditions of a uniform longitudinal plasma wave train including the effect of its interaction both at resonance and nonresonance, with a long wavelength ion-acoustic wave. (author)

  18. Development of time dependent safety analysis code for plasma anomaly events in fusion reactors

    International Nuclear Information System (INIS)

    Honda, Takuro; Okazaki, Takashi; Bartels, H.W.; Uckan, N.A.; Seki, Yasushi.

    1997-01-01

    A safety analysis code SAFALY has been developed to analyze plasma anomaly events in fusion reactors, e.g., a loss of plasma control. The code is a hybrid code comprising a zero-dimensional plasma dynamics and a one-dimensional thermal analysis of in-vessel components. The code evaluates the time evolution of plasma parameters and temperature distributions of in-vessel components. As the plasma-safety interface model, we proposed a robust plasma physics model taking into account updated data for safety assessment. For example, physics safety guidelines for beta limit, density limit and H-L mode confinement transition threshold power, etc. are provided in the model. The model of the in-vessel components are divided into twenty temperature regions in the poloidal direction taking account of radiative heat transfer between each surface of each region. This code can also describe the coolant behavior under hydraulic accidents with the results by hydraulics code and treat vaporization (sublimation) from plasma facing components (PFCs). Furthermore, the code includes the model of impurity transport form PFCs by using a transport probability and a time delay. Quantitative analysis based on the model is possible for a scenario of plasma passive shutdown. We examined the possibility of the code as a safety analysis code for plasma anomaly events in fusion reactors and had a prospect that it would contribute to the safety analysis of the International Thermonuclear Experimental Reactor (ITER). (author)

  19. Plasma data analysis using statistical analysis system

    International Nuclear Information System (INIS)

    Yoshida, Z.; Iwata, Y.; Fukuda, Y.; Inoue, N.

    1987-01-01

    Multivariate factor analysis has been applied to a plasma data base of REPUTE-1. The characteristics of the reverse field pinch plasma in REPUTE-1 are shown to be explained by four independent parameters which are described in the report. The well known scaling laws F/sub chi/ proportional to I/sub p/, T/sub e/ proportional to I/sub p/, and tau/sub E/ proportional to N/sub e/ are also confirmed. 4 refs., 8 figs., 1 tab

  20. Bifurcation analysis for ion acoustic waves in a strongly coupled plasma including trapped electrons

    Science.gov (United States)

    El-Labany, S. K.; El-Taibany, W. F.; Atteya, A.

    2018-02-01

    The nonlinear ion acoustic wave propagation in a strongly coupled plasma composed of ions and trapped electrons has been investigated. The reductive perturbation method is employed to derive a modified Korteweg-de Vries-Burgers (mKdV-Burgers) equation. To solve this equation in case of dissipative system, the tangent hyperbolic method is used, and a shock wave solution is obtained. Numerical investigations show that, the ion acoustic waves are significantly modified by the effect of polarization force, the trapped electrons and the viscosity coefficients. Applying the bifurcation theory to the dynamical system of the derived mKdV-Burgers equation, the phase portraits of the traveling wave solutions of both of dissipative and non-dissipative systems are analyzed. The present results could be helpful for a better understanding of the waves nonlinear propagation in a strongly coupled plasma, which can be produced by photoionizing laser-cooled and trapped electrons [1], and also in neutron stars or white dwarfs interior.

  1. Non-modal analysis in plasmas

    International Nuclear Information System (INIS)

    Mahajan, S.M.; Rogava, A.D.; Berezhiani, V.

    1996-01-01

    The techniques of non-modal analysis are applied to investigate the time evolution of a variety of plasma flows with velocity shear. It is shown that large transient amplifications may result for appropriate initial perturbations. The role of this amplification in determining the nonlinear dynamics of these systems (when all the normal modes are stable) is discussed. Examples are taken from Laboratory, astrophysical and cosmic plasmas

  2. Artificial neural networks for plasma spectroscopy analysis

    International Nuclear Information System (INIS)

    Morgan, W.L.; Larsen, J.T.; Goldstein, W.H.

    1992-01-01

    Artificial neural networks have been applied to a variety of signal processing and image recognition problems. Of the several common neural models the feed-forward, back-propagation network is well suited for the analysis of scientific laboratory data, which can be viewed as a pattern recognition problem. The authors present a discussion of the basic neural network concepts and illustrate its potential for analysis of experiments by applying it to the spectra of laser produced plasmas in order to obtain estimates of electron temperatures and densities. Although these are high temperature and density plasmas, the neural network technique may be of interest in the analysis of the low temperature and density plasmas characteristic of experiments and devices in gaseous electronics

  3. Analysis of the tuning characteristics of microwave plasma source

    International Nuclear Information System (INIS)

    Miotk, Robert; Jasiński, Mariusz; Mizeraczyk, Jerzy

    2016-01-01

    In this paper, we present an analysis of the tuning characteristics of waveguide-supplied metal-cylinder-based nozzleless microwave plasma source. This analysis has enabled to estimate the electron concentration n_e and electron frequency collisions ν in the plasma generated in nitrogen and in a mixture of nitrogen and ethanol vapour. The parameters n_e and ν are the basic quantities that characterize the plasma. The presented new plasma diagnostic method is particularly useful, when spectroscopic methods are useless. The presented plasma source is currently used in research of a hydrogen production from liquids.

  4. Sheet Fluorescence and Annular Analysis of Ultracold Neutral Plasmas

    International Nuclear Information System (INIS)

    Castro, J.; Gao, H.; Killian, T. C.

    2009-01-01

    Annular analysis of fluorescence imaging measurements on Ultracold Neutral Plasmas (UNPs) is demonstrated. Spatially-resolved fluorescence imaging of the strontium ions produces a spectrum that is Doppler-broadened due to the thermal ion velocity and shifted due to the ion expansion velocity. The fluorescence excitation beam is spatially narrowed into a sheet, allowing for localized analysis of ion temperatures within a volume of the plasma with small density variation. Annular analysis of fluorescence images permits an enhanced signal-to-noise ratio compared to previous fluorescence measurements done in strontium UNPs. Using this technique and analysis, plasma ion temperatures are measured and shown to display characteristics of plasmas with strong coupling such as disorder induced heating and kinetic energy oscillations.

  5. Plasma geometric optics analysis and computation

    International Nuclear Information System (INIS)

    Smith, T.M.

    1983-01-01

    Important practical applications in the generation, manipulation, and diagnosis of laboratory thermonuclear plasmas have created a need for elaborate computational capabilities in the study of high frequency wave propagation in plasmas. A reduced description of such waves suitable for digital computation is provided by the theory of plasma geometric optics. The existing theory is beset by a variety of special cases in which the straightforward analytical approach fails, and has been formulated with little attention to problems of numerical implementation of that analysis. The standard field equations are derived for the first time from kinetic theory. A discussion of certain terms previously, and erroneously, omitted from the expansion of the plasma constitutive relation is given. A powerful but little known computational prescription for determining the geometric optics field in the neighborhood of caustic singularities is rigorously developed, and a boundary layer analysis for the asymptotic matching of the plasma geometric optics field across caustic singularities is performed for the first time with considerable generality. A proper treatment of birefringence is detailed, wherein a breakdown of the fundamental perturbation theory is identified and circumvented. A general ray tracing computer code suitable for applications to radiation heating and diagnostic problems is presented and described

  6. Analysis of the tuning characteristics of microwave plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Miotk, Robert, E-mail: rmiotk@imp.gda.pl; Jasiński, Mariusz [Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdańsk (Poland); Mizeraczyk, Jerzy [Department of Marine Electronics, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia (Poland)

    2016-04-15

    In this paper, we present an analysis of the tuning characteristics of waveguide-supplied metal-cylinder-based nozzleless microwave plasma source. This analysis has enabled to estimate the electron concentration n{sub e} and electron frequency collisions ν in the plasma generated in nitrogen and in a mixture of nitrogen and ethanol vapour. The parameters n{sub e} and ν are the basic quantities that characterize the plasma. The presented new plasma diagnostic method is particularly useful, when spectroscopic methods are useless. The presented plasma source is currently used in research of a hydrogen production from liquids.

  7. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whitman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-01-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of sixteen plasma traces has been processed using this technique

  8. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whiteman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-11-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of the plasma traces has been processed with this technique

  9. The hidden radiation chemistry in plasma modification and XPS analysis of polymer surfaces

    International Nuclear Information System (INIS)

    George, G.A.; Le, T.T.; Elms, F.M.; Wood, B.J.

    1996-01-01

    Full text: The surface modification of polymers using plasma treatments is being widely researched to achieve changes in the surface energetics and consequent wetting and reactivity for a range of applications. These include i) adhesion for polymer bonding and composite material fabrication and ii) biocompatibility of polymers when used as orthopedic implants, catheters and prosthetics. A low pressure rf plasma produces a variety of species from the introduced gas which may react with the surface of a hydrocarbon polymer, such as polyethylene. In the case of 0 2 and H 2 0, these species include oxygen atoms, singlet molecular oxygen and hydroxyl radicals, all of which may oxidise and, depending on their energy, ablate the polymer surface. In order to better understand the reactive species formed both in and downstream from a plasma and the relative contributions of oxidation and ablation, self-assembled monolayers of n-alkane thiols on gold are being used as well characterised substrates for quantitative X-ray photoelectron spectroscopy (XPS). The identification and quantification of oxidised carbon species on plasma treated polymers from broad, asymmetric XPS signals is difficult, so derivatisation is often used to enhance sensitivity and specificity. For example, trifluoroacetic anhydride (TFAA) selectively labels hydroxyl functionality. The surface analysis of a modified polymer surface may be confounded by high energy radiation chemistry which may occur during XPS analysis. Examples include scission of carbon-halogen bonds (as in TFM adducts), decarboxylation and main-chain polyene formation. The extent of free-radical chemistry occurring in polyethylene while undergoing XPS analysis may be seen by both ESR and FT-IR analysis

  10. Analysis of IBW-driven plasma flows in tokamaks

    International Nuclear Information System (INIS)

    Berry, L.A.; Jaeger, E.F.; D'Azevedo, E.F.; Batchelor, D.B.; Carlsson, J.A.; Carter, M.D.; Cesario, R.

    2001-01-01

    Both theory and experiment have suggested that damping of Ion Bernstein Waves (IBWs) at ion cyclotron frequency harmonics could drive poloidal flows and lead to enhanced confinement for tokamaks. However, the early analyses were based on Reynolds stress closures of moment equations. More rigorous, finite Larmor radius (FLR) expansions of the radio frequency (RF) kinetic pressure for low harmonic interactions indicated that the Reynolds stress approximation was not generally valid, and resulted in significant changes in the plasma flow response. These changes were largest for wave interactions driven by finite Larmour radius effects. To provide a better assessment of higher harmonic interactions and IBW flow drive prospects, the electromagnetic (E and M) and RF kinetic force models are extended with no assumptions regarding the smallness of the ion Larmor radius. For both models, a spectral-width approximation was used to make the numerical analysis tractable. In addition, it was necessary to include the effects of plasma equilibrium gradients on the plasma conductivity and the RF-induced momentum in order to conserve energy and momentum. The analysis of high-harmonic IBW interactions for TFTR and FTU parameters indicates significant poloidal flow shears (relative to turbulence correlation times) for power levels available in present experiments. Recent advances in all-orders calculations of E and M fields in 2-D are also discussed. (author)

  11. Resistive mode in rotating plasma columns including the hall current

    International Nuclear Information System (INIS)

    Galvao, R.M.O.

    1983-01-01

    A new resistive mode is shown to exist in rotating plasma columns. The mode is localized in the neighbourhood of the radius where the angular velocity of the bulk plasma is equal to minus half the local angular velocity of the ions. This singular point is caused by the Hall term in the generalized Ohm law. The growth rate of the mode scales with eta sup(1/2), where eta is the plasma resistivity. (Author) [pt

  12. Structural stability analysis considerations in fusion reactor plasma chamber design

    International Nuclear Information System (INIS)

    Delaney, M.J.; Cramer, B.A.

    1978-01-01

    This paper presents an approach to analyzing a toroidal plasma chamber for the prevention of both static and dynamic buckling. Results of stability analyses performed for the doublet shaped plasma chamber of the General Atomic 3.8 meter radius TNS ignition test reactor are presented. Load conditions are the static external atmospheric pressure load and the dynamic plasma disruption pulse load. Methods for analysis of plasma chamber structures are presented for both types of load. Analysis for static buckling is based on idealizing the plasma chamber into standard structural shapes and applying classical cylinder and circular torus buckling equations. Results are verified using the Buckling of Shells of Revolution (BOSOR4) finite difference computer code. Analysis for the dynamic loading is based on a pulse buckling analysis method for circular cylinders

  13. Analysis of pedestal plasma transport

    International Nuclear Information System (INIS)

    Callen, J.D.; Groebner, R.J.; Osborne, T.H.; Canik, J.M.; Owen, L.W.; Pankin, A.Y.; Rafiq, T.; Rognlien, T.D.; Stacey, W.M.

    2010-01-01

    An H-mode edge pedestal plasma transport benchmarking exercise was undertaken for a single DIII-D pedestal. Transport modelling codes used include 1.5D interpretive (ONETWO, GTEDGE), 1.5D predictive (ASTRA) and 2D ones (SOLPS, UEDGE). The particular DIII-D discharge considered is 98889, which has a typical low density pedestal. Profiles for the edge plasma are obtained from Thomson and charge-exchange recombination data averaged over the last 20% of the average 33.53 ms repetition time between type I edge localized modes. The modelled density of recycled neutrals is largest in the divertor X-point region and causes the edge plasma source rate to vary by a factor ∼10 2 on the separatrix. Modelled poloidal variations in the densities and temperatures on flux surfaces are small on all flux surfaces up to within about 2.6 mm (ρ N > 0.99) of the mid-plane separatrix. For the assumed Fick's-diffusion-type laws, the radial heat and density fluxes vary poloidally by factors of 2-3 in the pedestal region; they are largest on the outboard mid-plane where flux surfaces are compressed and local radial gradients are largest. Convective heat flows are found to be small fractions of the electron (∼ 2 s -1 . Electron heat transport is found to be best characterized by electron-temperature-gradient-induced transport at the pedestal top and paleoclassical transport throughout the pedestal. The effective ion heat diffusivity in the pedestal has a different profile from the neoclassical prediction and may be smaller than it. The very small effective density diffusivity may be the result of an inward pinch flow nearly balancing a diffusive outward radial density flux. The inward ion pinch velocity and density diffusion coefficient are determined by a new interpretive analysis technique that uses information from the force balance (momentum conservation) equations; the paleoclassical transport model provides a plausible explanation of these new results. Finally, the measurements

  14. Stages of Plasma Cell Neoplasms (Including Multiple Myeloma)

    Science.gov (United States)

    ... cancer treatment is also called biotherapy or immunotherapy. Immunomodulators are a type of biologic therapy. Thalidomide , lenalidomide , and pomalidomide are immunomodulators used to treat multiple myeloma and other plasma ...

  15. Plasma processes including electron beam for off-gases purification

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Witman, S.; Licki, J.

    2011-01-01

    Complete text of publication follows. Non-thermal plasma technologies based on different methods of plasma generation are being applied for ozone generation for different applications, waste water and off-gases treatment. Plasmas create reactive species, in particular ions, radicals or other reactive compounds, which can decompose pollutant molecules, organic particulate matter or soot. Electron beam flue gas treatment is another plasma-based technology which has been successfully demonstrated on industrial scale coal fired power plants. High efficiency of SO 2 (> 95%) and NO x (> 70%) has been obtained and industrial plant applying this process has been built in Poland. The further investigations carried out all over the world have illustrated that the process can be applied for poly-aromatic hydrocarbons (PAH) destruction as well, and just recently research laboratories in the US and South Korea have reported in the feasibility of the process for mercury removal from the flue gas. The recent studies concern a new type of accelerators implementation in the industrial scale, application of the process in the high sulfur oil fired boilers and Diesel off - gases purification. The treatment of the flue gases with the high NOx concentration is a special challenge for the technology since the main energy consumption (and applied accelerators power) is related to this pollutant content in the processed off gases. The pulse beams and scavenger application can be a solution to reduce investment and operational costs. The further development of the technology is directly connected with high power accelerators development. Acknowledgement: The R and D activities are supported by the European Regional Development Found in the frame of the project PlasTEP 'Dissemination and fostering of plasma based technological innovation for environment protection in the Baltic Sea Region'.

  16. Comprehensive Analysis of Low-Molecular-Weight Human Plasma Proteome Using Top-Down Mass Spectrometry.

    Science.gov (United States)

    Cheon, Dong Huey; Nam, Eun Ji; Park, Kyu Hyung; Woo, Se Joon; Lee, Hye Jin; Kim, Hee Cheol; Yang, Eun Gyeong; Lee, Cheolju; Lee, Ji Eun

    2016-01-04

    While human plasma serves as a great source for disease diagnosis, low-molecular-weight (LMW) proteome (mass spectrometry to analyze the LMW proteoforms present in four types of human plasma samples pooled from three healthy controls (HCs) without immunoaffinity depletion and with depletion of the top two, six, and seven high-abundance proteins. The LMW proteoforms were first fractionated based on molecular weight using gel-eluted liquid fraction entrapment electrophoresis (GELFrEE). Then, the GELFrEE fractions containing up to 30 kDa were subjected to nanocapillary-LC-MS/MS, and the high-resolution MS and MS/MS data were processed using ProSightPC 3.0. As a result, a total of 442 LMW proteins and cleaved products, including those with post-translational modifications and single amino acid variations, were identified. From additional comparative analysis of plasma samples without immunoaffinity depletion between HCs and colorectal cancer (CRC) patients via top-down approach, tens of LMW proteoforms, including platelet factor 4, were found to show >1.5-fold changes between the plasma samples of HCs and CRC patients, and six of the LMW proteins were verified by Western blot analysis.

  17. Analysis of plasma instabilities and verification of the BOUT code for the Large Plasma Device

    International Nuclear Information System (INIS)

    Popovich, P.; Carter, T. A.; Friedman, B.; Umansky, M. V.

    2010-01-01

    The properties of linear instabilities in the Large Plasma Device [W. Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)] are studied both through analytic calculations and solving numerically a system of linearized collisional plasma fluid equations using the three-dimensional fluid code BOUT[M. Umansky et al., Contrib. Plasma Phys. 180, 887 (2009)], which has been successfully modified to treat cylindrical geometry. Instability drive from plasma pressure gradients and flows is considered, focusing on resistive drift waves and the Kelvin-Helmholtz and rotational interchange instabilities. A general linear dispersion relation for partially ionized collisional plasmas including these modes is derived and analyzed. For Large Plasma Device relevant profiles including strongly driven flows, it is found that all three modes can have comparable growth rates and frequencies. Detailed comparison with solutions of the analytic dispersion relation demonstrates that BOUT accurately reproduces all characteristics of linear modes in this system.

  18. Local transport analysis of L-mode plasmas in JT-60 tokamak

    International Nuclear Information System (INIS)

    Hirayama, Toshio; Kikuchi, Mitsuru; Shirai, Hiroshi; Shimizu, Katsuhiro; Yagi, Masatoshi; Koide, Yoshihiko; Ishida, Shinichi; Azumi, Masafumi.

    1991-03-01

    Local heat transport has been studied in auxiliary heated JT-60 plasmas with emphasis on understanding the deteriorated confinement observed in L-mode plasmas. The systematic experiment and analysis have been carried out in L-mode phase of divertor (single null, lower X-point), and limiter discharges with hydrogen neutral beam heating into hydrogen plasmas, based on sets of consistent experimental data including ion temperature profiles from CXR measurements. The deterioration in the energy confinement time with increasing the auxiliary heating power, so-called the power scaling, is mainly due to the degradation in ion energy transport. The confinement improvement as the plasma current increases is followed by both improvement in ion and electron transport properties. It is found that the ion thermal diffusivity has an approval dependence on the density. High ion temperature (T i (0) ≤ 12 keV) L-mode plasmas are attained at high β p up to 3.5. The centrally peaked ion temperature is significantly due to the improvement in ion transport property, which is reduced to the level of the electron thermal diffusivities. (author)

  19. Plasma Cell Neoplasms (Including Multiple Myeloma) Treatment (PDQ®)—Patient Version

    Science.gov (United States)

    Plasma cell neoplasms occur when abnormal plasma cells or myeloma cells form tumors in the bones or soft tissues of the body. Multiple myeloma, plasmacytoma, lymphoplasmacytic lymphoma, and monoclonal gammopathy of undetermined significance (MGUS) are different types of plasma cell neoplasms. Find out about risk factors, symptoms, diagnostic tests, prognosis, and treatment for these diseases.

  20. Quantitative, multiplexed workflow for deep analysis of human blood plasma and biomarker discovery by mass spectrometry.

    Science.gov (United States)

    Keshishian, Hasmik; Burgess, Michael W; Specht, Harrison; Wallace, Luke; Clauser, Karl R; Gillette, Michael A; Carr, Steven A

    2017-08-01

    Proteomic characterization of blood plasma is of central importance to clinical proteomics and particularly to biomarker discovery studies. The vast dynamic range and high complexity of the plasma proteome have, however, proven to be serious challenges and have often led to unacceptable tradeoffs between depth of coverage and sample throughput. We present an optimized sample-processing pipeline for analysis of the human plasma proteome that provides greatly increased depth of detection, improved quantitative precision and much higher sample analysis throughput as compared with prior methods. The process includes abundant protein depletion, isobaric labeling at the peptide level for multiplexed relative quantification and ultra-high-performance liquid chromatography coupled to accurate-mass, high-resolution tandem mass spectrometry analysis of peptides fractionated off-line by basic pH reversed-phase (bRP) chromatography. The overall reproducibility of the process, including immunoaffinity depletion, is high, with a process replicate coefficient of variation (CV) of 4,500 proteins are detected and quantified per patient sample on average, with two or more peptides per protein and starting from as little as 200 μl of plasma. The approach can be multiplexed up to 10-plex using tandem mass tags (TMT) reagents, further increasing throughput, albeit with some decrease in the number of proteins quantified. In addition, we provide a rapid protocol for analysis of nonfractionated depleted plasma samples analyzed in 10-plex. This provides ∼600 quantified proteins for each of the ten samples in ∼5 h of instrument time.

  1. Stability analysis and reconstruction of wave distribution functions in warm plasmas

    International Nuclear Information System (INIS)

    Oscarsson, T.E.

    1989-05-01

    The purpose of this thesis is first to describe stability analysis and reconstruction of the wave distribution function (WDF) separately, and then to show how the two approaches can be combined in an investigation of satellite data. To demonstrate the type of stability investigation that is often used in space physics we study instabilities below the local proton gyrofrequency which are caused by anisotropic proton distributions. Arbitrary angles between the wavevector and the background magnetic field are considered, and effects of warm plasma on the wave propagation properties are included. We also comment briefly given on an often-used scheme for classifying instabilities. In our discussion on WDF analysis we develop a completely new and general method for reconstructing the WDF. Our scheme can be used to reconstruct the distribution function of waves in warm as well as cold plasma. Doppler effects introduced by satellite motion are included, and the reconstructions can be performed over a broad frequency range simultaneously. The applicability of our new WDF reconstruction method is studied in model problems and in an application to observations made by the Swedish satellite Viking. In the application to Viking data we combine stability and WDF analyses in a unique way that promises to become an important tool in future studies of wave-particle interactions in space plasmas. (author)

  2. Transport analysis of oscillatory state for plasma dynamics in helical plasmas

    International Nuclear Information System (INIS)

    Toda, S.; Itoh, K.

    2012-11-01

    In helical plasmas, two kinds of the oscillation for the plasma quantities are experimentally observed. Firstly, the limit cycle phenomena in the temporal evolution of the electrostatic potential, namely the electric pulsation, have been observed in the core region. The temporally self-generated oscillation of the radial electric field is shown as a simulation result in the core region. The dependence of the transition point for the radial electric field on the source is examined. Secondly, the density limit oscillation in the helical device was reported. To realize the oscillation phenomena at the density limit, the temporal evolution of the density profile is newly included in a simulation when the radiative loss is calculated in the edge region. Two stationary plasma states, where the transport loss or radiative loss is dominant in the edge region, are obtained. The dynamics of the plasma quantity is found to show the transition from the transport-dominated state to the radiation-dominated state. (author)

  3. EM wave propagation analysis in plasma covered radar absorbing material

    CERN Document Server

    Singh, Hema; Rawat, Harish Singh

    2017-01-01

    This book focuses on EM propagation characteristics within multilayered plasma-dielectric-metallic media. The method used for analysis is impedance transformation method. Plasma covered radar absorbing material is approximated as a multi-layered dielectric medium. The plasma is considered to be bounded homogeneous/inhomogeneous medium. The reflection coefficient and hence return loss is analytically derived. The role of plasma parameters, such as electron density, collision frequency, plasma thickness, and plasma density profile in the absorption behavior of multi-layered plasma-RAM structure is described. This book provides a clearer picture of EM propagation within plasma. The reader will get an insight of plasma parameters that play significant role in deciding the absorption characteristics of plasma covered surfaces.

  4. Opacity and atomic analysis of double pulse laser ablated Li plasma

    Science.gov (United States)

    Sivakumaran, V.; Joshi, H. C.; Kumar, Ajai

    2014-09-01

    Opacity effects for neutral and ionic emission lines of lithium have been investigated by Atomic Data Analysis Structure (ADAS). Line ratios and opacity corrected photon emissivity coefficients are calculated over a wide range of electron temperatures and densities. The experimentally measured temporal evolution of the line profiles of the over dense Li plasma formed in the double pulse laser ablation experiment have been explained using the ADAS analysis and the plasma parameters of the plasma plume under consideration have been estimated. These results could be projected as a diagnostic tool to estimate plasma parameters of an over dense lithium plasma.

  5. Chemical analysis of refractories by plasma spectrometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.

    1990-01-01

    X-ray spectrometry has been, since the last two or three decades, the traditional procedure for the chemical analysis of refractories, due to its high degree of accuracy and speed to produce analytical results. An interesting alternative to X-ray fluorescence is provided by the Inductively Coupled Plasma Spectrometry technique, for those laboratories where wet chemistry facilities are already available or process control is not required at high speed, or investiment costs have to be low. This paper presents results obtained by plasma spectroscopy for the analysis of silico - aluminous refractories, showing calibration curves, precion and detection limits. Considerations and comparisons with X-ray fluorescence are also made. (author) [pt

  6. Magnetic Field Analysis of Plasma Guide in Galathea Trimyx

    Directory of Open Access Journals (Sweden)

    Jin Xianji

    2016-01-01

    Full Text Available You Galathea Trimyx is a kind of small size, multipole magnetic confinement devices in controlled thermonuclear fusion. Plasma guide is one of important part in Galathea Trimyx which is responsible for transporting fast and slow plasma bunches ejected from plasma gun. The distribution and uniformity of magnetic field in completed plasma guide is analyzed in detail, including in x -axis direction and in z-axis direction. On the basis, the motion of plasma in the guide is discussed.

  7. Plasma L-tryptophan concentration in major depressive disorder: new data and meta-analysis.

    Science.gov (United States)

    Ogawa, Shintaro; Fujii, Takashi; Koga, Norie; Hori, Hiroaki; Teraishi, Toshiya; Hattori, Kotaro; Noda, Takamasa; Higuchi, Teruhiko; Motohashi, Nobutaka; Kunugi, Hiroshi

    2014-09-01

    Tryptophan, an essential amino acid, is the precursor to serotonin and is metabolized mainly by the kynurenine pathway. Both serotonin and kynurenine have been implicated in the pathophysiology of major depressive disorder (MDD). However, plasma tryptophan concentration in patients with MDD has not unequivocally been reported to be decreased, which prompted us to perform a meta-analysis on previous studies and our own data. We searched the PubMed database for case-control studies published until August 31, 2013, using the search terms plasma AND tryptophan AND synonyms for MDD. An additional search was performed for the term amino acid instead of tryptophan. We obtained our own data in 66 patients with MDD (DSM-IV) and 82 controls who were recruited from March 2011 to July 2012. The majority of the patients were medicated (N = 53). Total plasma tryptophan concentrations were measured by the liquid chromatography/mass spectrometry method. We scrutinized 160 studies for eligibility. Original articles that were written in English and documented plasma tryptophan values in patients and controls were selected. We included 24 studies from the literature and our own data in the meta-analysis, which involved a total of 744 patients and 793 controls. Data on unmedicated patients (N = 156) and their comparison subjects (N = 203) were also extracted. To see the possible correlation between tryptophan concentrations and depression severity, meta-regression analysis was performed for 10 studies with the Hamilton Depression Rating Scale 17-item version score. In our case-control study, mean (SD) plasma tryptophan level was significantly decreased in the MDD patients versus the controls (53.9 [10.9] vs 57.2 [11.3] μmol/L; P = .03). The meta-analysis after adjusting for publication bias showed a significant decrease in patients with MDD with a modest effect size (Hedges g, -0.45). However, analysis on unmedicated subjects yielded a large effect (Hedges g, -0.84; P = .00015). We

  8. Three-Dimensional Simulation of Plasma Deformation During Contact Opening in a Circuit Breaker, Including the Analysis of Kink Instability and Sausage Instability

    International Nuclear Information System (INIS)

    Abbasi, Vahid; Gholami, Ahmad; Niayesh, Kaveh

    2012-01-01

    A three-dimensional (3-D) transient model has been developed to investigate plasma deformation driven by a magnetic field and its influence on arc stability in a circuit breaker. The 3-D distribution of electric current density is obtained from a current continuity equation along with the generalized Ohm's law; while the magnetic field induced by the current flowing through the arc column is calculated by the magnetic vector potential equation. When gas interacts with an arc column, fundamental factors, such as Ampere's law, Ohm's law, the turbulence model, transport equations of mass, momentum and energy of plasma flow, have to be coupled for analyzing the phenomenon. The coupled interactions between arc and plasma flow are described in the framework of time-dependent magnetohydrodynamic (MHD) equations in conjunction with a K-ε turbulence model. Simulations have been focused on sausage and kink instabilities in plasma (these phenomena are related to pinch effects and electromagnetic fields). The 3-D simulation reveals the relation between plasma deformation and instability phenomena, which affect arc stability during circuit breaker operation. Plasma deformation is the consequence of coupled interactions between the electromagnetic force and plasma flow described in simulations. (plasma technology)

  9. Treatment Options for Plasma Cell Neoplasms (Including Multiple Myeloma)

    Science.gov (United States)

    ... cancer treatment is also called biotherapy or immunotherapy. Immunomodulators are a type of biologic therapy. Thalidomide , lenalidomide , and pomalidomide are immunomodulators used to treat multiple myeloma and other plasma ...

  10. Design of next step tokamak: Consistent analysis of plasma performance flux composition and poloidal field system

    International Nuclear Information System (INIS)

    Ane, J.M.; Grandgirard, V.; Albajar, F.; Johner, J.

    2001-01-01

    A consistent and simple approach to derive plasma scenarios for next step tokamak design is presented. It is based on successive plasma equilibria snapshots from plasma breakdown to end of ramp-down. Temperature and density profiles for each equilibrium are derived from a 2D plasma model. The time interval between two successive equilibria is then computed from the toroidal field magnetic energy balance, the resistive term of which depends on n, T profiles. This approach provides a consistent analysis of plasma performance, flux consumption and PF system, including average voltages waveforms across the PF coils. The plasma model and the Poynting theorem for the toroidal magnetic energy are presented. Application to ITER-FEAT and to M2, a Q=5 machine designed at CEA, are shown. (author)

  11. Plasma brake model for preliminary mission analysis

    Science.gov (United States)

    Orsini, Leonardo; Niccolai, Lorenzo; Mengali, Giovanni; Quarta, Alessandro A.

    2018-03-01

    Plasma brake is an innovative propellantless propulsion system concept that exploits the Coulomb collisions between a charged tether and the ions in the surrounding environment (typically, the ionosphere) to generate an electrostatic force orthogonal to the tether direction. Previous studies on the plasma brake effect have emphasized the existence of a number of different parameters necessary to obtain an accurate description of the propulsive acceleration from a physical viewpoint. The aim of this work is to discuss an analytical model capable of estimating, with the accuracy required by a preliminary mission analysis, the performance of a spacecraft equipped with a plasma brake in a (near-circular) low Earth orbit. The simplified mathematical model is first validated through numerical simulations, and is then used to evaluate the plasma brake performance in some typical mission scenarios, in order to quantify the influence of the system parameters on the mission performance index.

  12. Plasma exchange for renal vasculitis and idiopathic rapidly progressive glomerulonephritis: a meta-analysis

    DEFF Research Database (Denmark)

    Walsh, Michael; Catapano, Fausta; Szpirt, Wladimir

    2011-01-01

    Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis.......Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis....

  13. Dispersion in a thermal plasma including arbitrary degeneracy and quantum recoil.

    Science.gov (United States)

    Melrose, D B; Mushtaq, A

    2010-11-01

    The longitudinal response function for a thermal electron gas is calculated including two quantum effects exactly, degeneracy, and the quantum recoil. The Fermi-Dirac distribution is expanded in powers of a parameter that is small in the nondegenerate limit and the response function is evaluated in terms of the conventional plasma dispersion function to arbitrary order in this parameter. The infinite sum is performed in terms of polylogarithms in the long-wavelength and quasistatic limits, giving results that apply for arbitrary degeneracy. The results are applied to the dispersion relations for Langmuir waves and to screening, reproducing known results in the nondegenerate and completely degenerate limits, and generalizing them to arbitrary degeneracy.

  14. Analysis of 16 plasma vortex events in the geomagnetic tail

    International Nuclear Information System (INIS)

    Birn, J.; Hones, E.W. Jr.; Bame, S.J.; Russel, C.T.

    1985-01-01

    The analysis of 16 plasma vortex occurrences in the magnetotail plasma sheet of Hones et al. (1983) is extended. We used two- and three-dimensional plasma measurements and three-dimensional magnetic field measurements to study phase relations, energy propagation, and polarization properties. The results point toward an interpretation as a slow strongly damped MHD eigenmode which is generated by tailward traveling perturbations at the low-latitude interface between plasma sheet and magnetosheath

  15. Determination of selenium and zinc in rat plasma by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz A, Luis.

    1997-01-01

    To evaluate the effects on the thyroid function when simple or multiple zinc, selenium and iodine deficiency are induced, research was carried out in laboratory animals. For simultaneously determining the Zn and Se concentration in rat plasma, an instrumental neutron activation analysis technique was applied. A clean laboratory, was used for the preparation of samples. High purity materials were used for sample collection and storage. Irradiation, decay and counting parameters were optimized to obtain the best sensitivity, accuracy and precision analysis. The Zn and Se concentrations were determined from the peak area of gamma-rays of 1115 and 265 KeV respectively. The analytical methodology used was validated with standard reference materials. The procedure used for the analysis, including the phases of collection, treatment of the samples and analytical determination was considered suitable for the study of trace elements in biological samples, especially plasma. (author) [es

  16. Curcuminoids Lower Plasma Leptin Concentrations: A Meta-analysis.

    Science.gov (United States)

    Atkin, Stephen L; Katsiki, Niki; Derosa, Giuseppe; Maffioli, Pamela; Sahebkar, Amirhossein

    2017-12-01

    Curcumin is a naturally occurring polyphenol that has been suggested to improve several metabolic diseases. Leptin is an adipokine involved in metabolic status and appetite, with marked crosstalk with other systems. Available data suggest that curcumin may affect leptin levels; therefore, this meta-analysis was performed to evaluate this. A systematic review and meta-analysis were undertaken on all randomized controlled trials of curcumin studies that included the measurement of leptin. The search included PubMed-Medline, Scopus, ISI Web of Knowledge, and Google Scholar databases. Quantitative data synthesis was performed by using a random-effects model, with standardized mean difference and 95% confidence interval as summary statistics. A funnel plot, Begg's rank correlation, and Egger's weighted regression tests assessed the presence of publication bias. Four eligible articles comprising five treatment arms were selected for the meta-analysis. Meta-analysis showed a significant decrease in plasma leptin concentrations following curcumin treatment (standardized mean difference: -0.69, 95% confidence interval: -1.16, -0.23, p = 0.003; I 2  = 76.53%). There was no evidence of publication bias. This meta-analysis showed that curcumin supplementation is associated with a decrease in leptin levels that may be regarded as a potential mechanism for the metabolic effects of curcumin. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  17. [Plasma properties research: Task 3

    International Nuclear Information System (INIS)

    1992-01-01

    The principal research activities of the Magneto-Fluid Dynamics Division relate to magnetic fusion plasma physics. In addition, there is a modest amount of work in closely related areas, including space plasma physics, fluid dynamics, and dynamical systems. Members of the Magneto-Fluid Dynamics Division maintain close contacts with fusion researchers in the US and abroad. Some of the work of the Division is clearly directed towards ITER and TPX, while other problems relate to the broader development of fusion plasma physics and to the support of other issues arising in the many experimental programs. Topics of some note in the last year that are discussed in this report are: Application of sophisticated statistical techniques to tokamak data reduction, including time series analysis of TFTR fluctuation data and spline analysis of profile data. Continuing development of edge plasma and divertor modelling, including initial ergodic divertor studies. Analysis of energetic fusion products losses from TFTR plasmas. Examination of anomalous transport in dynamical systems induced by chaotic-like Hamiltonian motion. Numerical simulation of the development of singular MHD equilibria. Exploration of the validity of moment expansions of kinetic equations for weakly collisional systems. Studies of RF- and ripple-induced helium ash removal. Ballooning mode studies in fluids and rotating stars. Studies in dynamical systems, including explosive instabilities, development of chaos, and motion of collisionless particles in a domain with overlapping islands

  18. Incompressible LFR MHD. A fluid model for stability analysis of a fusion plasma

    International Nuclear Information System (INIS)

    Scheffel, J.; Faghihi, M.

    1986-10-01

    A fluid model including FLR effects, named Incompressible Finite Larmor Radius MagnetoHydroDynamics, is presented and derived in this paper. It is an extension of ordinary, incompressible MHD to include the Larmor radius effects due to ion gyroviscosity, Hall current and electron diamagnetism. It is intended to use the model for stability analysis, on the Alfven wave time scale, of a fusion plasma and it is consequently based on transport coefficients in the collisionless limit. It will be demonstrated that for a fairly dense and cool plasma, such as for the EXTRAP z-pinch, all three Larmor radius effects may become important, that for a JET-type plasma no FLR effect is pronounced, and that in a reactor plasma the Hall and electron diamagnetism term may play a role. For scaling lengths signigicantly smaller than the plasma radius the effect of the FLR terms becomes enhanced. To study the importance of the choice of equations of state for the model the m=1 and k 2 r 2 towards infinity instability in cylindrical geometry is given special attention for zero Larmor radius. The full stability criterion of the double adiabatic model, including pressure anisotropy, is presented for what we believe to be the first time. It is found that when perpendicular p > parallel p stability can be reached for very high plasma perpendicular β-values. We demonstrate that no less complicated energy conserving fluid model, which takes into account pressure anisotropy, other than the double adiabativ model can be obtained. Since pressure anisotropy generally only weakly affects stability, we can assume isotropy in the Incompressible FLR MHD model. Also, the energy equation is replaced by the incompressibility condition, making FLR terms appearing in the energy equation irrelevant. (authors)

  19. Statin therapy and plasma vitamin E concentrations: A systematic review and meta-analysis of randomized placebo-controlled trials.

    Science.gov (United States)

    Sahebkar, Amirhossein; Simental-Mendía, Luis E; Ferretti, Gianna; Bacchetti, Tiziana; Golledge, Jonathan

    2015-12-01

    Vitamin E is one of the most important natural antioxidants, and its plasma levels are inversely associated with the progression of atherosclerosis. There have been reports suggesting a potential negative effect of statin therapy on plasma vitamin E levels. The aim of this meta-analysis was to determine the impact of statin therapy on plasma vitamin E concentrations. PubMed-Medline, SCOPUS, Web of Science and Google Scholar databases were searched to identify randomized placebo-controlled trials evaluating the impact of statins on plasma vitamin E concentrations from inception to February 27, 2015. A systematic assessment of bias in the included studies was performed using the Cochrane criteria. A random-effects model (using DerSimonian-Laird method) and the generic inverse variance method were used to examine the effect of statins on plasma vitamin E concentrations. Heterogeneity was quantitatively assessed using the I(2) index. Sensitivity analysis was conducted using the leave-one-out method. A meta-analysis of data from 8 randomized treatment arms including 504 participants indicated a significant reduction in plasma vitamin E concentrations following statin treatment (WMD: -16.30%, 95% CI: -16.93, -15.98, p statin therapy (WMD: 29.35%, 95% CI: 24.98, 33.72, p Statin therapy was not associated with any significant alteration in LDL vitamin E content (SMD: 0.003, 95% CI: -0.90, 0.90, p = 0.995). Findings of the present study suggest that statin therapy has no negative impact on plasma vitamin E concentrations or LDL vitamin E content. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Liquid steel analysis by laser-induced plasma spectroscopy

    International Nuclear Information System (INIS)

    Gruber, J.

    2002-11-01

    When a nanosecond pulsed laser is focused onto a sample and the intensity exceeds a certain threshold, material is vaporized and a plasma is formed above the sample surface. The laser-light becomes increasingly absorbed by inverse bremsstrahlung and by photo-excitation and photo-ionization of atoms and molecules. The positive feedback, by which the number of energetic electrons for ionization is increased in an avalanche-like manner under the influence of laser-light, is the so-called optical breakdown. Radiating excited atoms and ions within the expanding plasma plume produce a characteristic optical emission spectrum. A spectroscopic analysis of this optical emission of the laser-induced plasma permits a qualitative and quantitative chemical analysis of the investigated sample. This technique is therefore often called laser-induced plasma spectroscopy (LIPS) or laser-induced breakdown spectroscopy (LIBS). LIPS is a fast non-contact technique, by which solid, liquid or gaseous samples can be analyzed with respect to their chemical composition. Hence, it is an appropriate tool for the rapid in-situ analysis of not easily accessible surfaces for process control in industrial environments. In this work, LIPS was studied as a technique to determine the chemical composition of solid and liquid steel. A LIPS set-up was designed and built for the remote and continuous in-situ analysis of the steel melt. Calibration curves were prepared for the LIPS analysis of Cr, Mn, Ni and Cu in solid steel using reference samples with known composition. In laboratory experiments an induction furnace was used to melt steel samples in crucibles, which were placed at a working distance of 1.5 m away from the LIPS apparatus. The response of the LIPS system was monitored on-line during the addition of pure elements to the liquid steel bath within certain concentration ranges (Cr: 0.11 - 13.8 wt%, Cu: 0.044 - 0.54 wt%, Mn: 1.38 - 2.5 wt%, Ni: 0.049 - 5.92 wt%). The analysis of an element

  1. Surface analysis of 316 stainless steel treated with cold atmospheric plasma

    Energy Technology Data Exchange (ETDEWEB)

    Williams, David F., E-mail: david.williams@surrey.ac.uk [Department of Mechanical Engineering Sciences, University Of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); TWI Ltd Granta Park Great Abington, Cambridge CB21 6AL (United Kingdom); Kellar, Ewen J.C. [TWI Ltd Granta Park Great Abington, Cambridge CB21 6AL (United Kingdom); Jesson, David A.; Watts, John F. [Department of Mechanical Engineering Sciences, University Of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2017-05-01

    Highlights: • Reduction in carbon contamination from ∼80 at.% to 40 at.% after 15 s treatment. • Associated carbon thickness reduction from 4.5 nm to 0.5 nm. • Area treated by torch has a diameter of 11 mm measured using imaging XPS. - Abstract: The surface of 316 stainless steel has been modified using cold atmospheric plasma (CAP) to increase the surface free energy (by cleaning the and chemically activating the surface)IN preparation for subsequent processes such as painting, coating or adhesive bonding. The analyses carried out, on CAP treated 316 stainless steel surfaces, includes X-ray photoelectron spectroscopy (XPS), imaging XPS (iXPS), and surface free energy (SFE) analysis using contact angle measurements. The CAP treatment is shown to increase the SFE of as-received 316 stainless steel from ∼39 mJ m{sup −1} to >72 mJ m{sup −1} after a short exposure to the plasma torch. This was found to correlate to a reduction in adventitious carbon, as determined by XPS analysis of the surface. The reduction from ∼90 at% to ∼30% and ∼39 at%, after being plasma treated for 5 min and 15 s respectively, shows that the process is relatively quick at changing the surface. It is suggested that the mechanism that causes the increase in surface free energy is chain scission of the hydrocarbon contamination triggered by free electrons in the plasma plume followed by chemical functionalisation of the metal oxide surface and some of the remaining carbon contamination layer.

  2. LC-MS analysis of the plasma metabolome–a novel sample preparation strategy

    DEFF Research Database (Denmark)

    Skov, Kasper; Hadrup, Niels; Smedsgaard, Jørn

    2015-01-01

    Blood plasma is a well-known body fluid often analyzed in studies on the effects of toxic compounds as physiological or chemical induced changes in the mammalian body are reflected in the plasma metabolome. Sample preparation prior to LC-MS based analysis of the plasma metabolome is a challenge...... as plasma contains compounds with very different properties. Besides, proteins, which usually are precipitated with organic solvent, phospholipids, are known to cause ion suppression in electrospray mass spectrometry. We have compared two different sample preparation techniques prior to LC-qTOF analysis...... of plasma samples: The first is protein precipitation; the second is protein precipitation followed by solid phase extraction with sub-fractionation into three sub-samples; a phospholipid, a lipid and a polar sub-fraction. Molecular feature extraction of the data files from LC-qTOF analysis of the samples...

  3. A statistical approach to plasma profile analysis

    International Nuclear Information System (INIS)

    Kardaun, O.J.W.F.; McCarthy, P.J.; Lackner, K.; Riedel, K.S.

    1990-05-01

    A general statistical approach to the parameterisation and analysis of tokamak profiles is presented. The modelling of the profile dependence on both the radius and the plasma parameters is discussed, and pertinent, classical as well as robust, methods of estimation are reviewed. Special attention is given to statistical tests for discriminating between the various models, and to the construction of confidence intervals for the parameterised profiles and the associated global quantities. The statistical approach is shown to provide a rigorous approach to the empirical testing of plasma profile invariance. (orig.)

  4. MHD model including small-scale perturbations in a plasma with temperature variations

    International Nuclear Information System (INIS)

    Kuvshinov, B.N.; Mikhailovskii, A.B.

    1996-01-01

    The possibility is studied of using a hydrodynamic model to describe a magnetized plasma with density and temperature variations on scales that are arbitrary with respect to the ion Larmor radius. It is shown that the inertial component of the transverse ion thermal flux should be taken into account. This component is found from the collisionless kinetic equation. It can also be obtained from the equations of the Grad type. A set of two-dimensional hydrodynamic equations for ions is obtained with this component taken into account. These equations are used to derive model hydrodynamic expressions for the density and temperature variations. It is shown that, for large-scale perturbations (when the wavelengths are longer than the ion Larmor radius), the expressions derived coincide with the corresponding kinetic expressions and, for perturbations on sub-Larmor scales (when the wavelengths are shorter than the Larmor radius), they agree qualitatively. Hydrodynamic dispersion relations are derived for several types of drift waves with arbitrary wavenumbers. The range of applicability of the MHD model is determined from a comparison of these dispersion relations with the kinetic ones. It is noted that, on the basis of results obtained, drift effects can be included in numerical MHD codes for studying plasma instabilities in high-temperature regimes in tokamaks

  5. Analysis of tokamak plasma confinement modes using the fast

    Indian Academy of Sciences (India)

    The Fourier analysis is a satisfactory technique for detecting plasma confinement modes in tokamaks. The confinement mode of tokamak plasma was analysed using the fast Fourier transformation (FFT). For this purpose, we used the data of Mirnov coils that is one of the identifying tools in the IR-T1 tokamak, with and ...

  6. RACLETTE: a model for evaluating the thermal response of plasma facing components to slow high power plasma transients. Part II: Analysis of ITER plasma facing components

    Science.gov (United States)

    Federici, Gianfranco; Raffray, A. René

    1997-04-01

    The transient thermal model RACLETTE (acronym of Rate Analysis Code for pLasma Energy Transfer Transient Evaluation) described in part I of this paper is applied here to analyse the heat transfer and erosion effects of various slow (100 ms-10 s) high power energy transients on the actively cooled plasma facing components (PFCs) of the International Thermonuclear Experimental Reactor (ITER). These have a strong bearing on the PFC design and need careful analysis. The relevant parameters affecting the heat transfer during the plasma excursions are established. The temperature variation with time and space is evaluated together with the extent of vaporisation and melting (the latter only for metals) for the different candidate armour materials considered for the design (i.e., Be for the primary first wall, Be and CFCs for the limiter, Be, W, and CFCs for the divertor plates) and including for certain cases low-density vapour shielding effects. The critical heat flux, the change of the coolant parameters and the possible severe degradation of the coolant heat removal capability that could result under certain conditions during these transients, for example for the limiter, are also evaluated. Based on the results, the design implications on the heat removal performance and erosion damage of the variuos ITER PFCs are critically discussed and some recommendations are made for the selection of the most adequate protection materials and optimum armour thickness.

  7. Performance analyses of Elmo Bumpy Torus plasmas and plasma support systems

    International Nuclear Information System (INIS)

    Fenstermacher, M.E.

    1979-01-01

    The development and applcation of the OASIS Code (Operational Analysis of ELMO Bumpy Torus Support and Ignition Systems) for the study of EBT device and plasma performance are presented. The code performs a time-independent, zero-dimensional self-consistent calculation of plasma and plasmasupport systems parameters for the physics and engineering of EBT devices. The features of OASIS modeling for the EBT plasma include: (1) particle balance of the bulk toroidal and electron ring plasma components for experimental (H-H, D-D, He-He etc.) as well as reactor (D-T) devices; (2) energy balance in the bulk and ring plasmas for externally heated or ignition devices; (3) alpha particle effects for reactor devices; (4) auxiliary heating effects, including microwave (ECRH), RF heating (e.g., ICRH), and neutral beam methods; and (5) ignition conditions, including fusion power, alpha power and neutron wall loading. The performance studies using OASIS focussed on variation in plasma and device size and on microwave input power and frequency. An additional study was performed to determine the characteristics of an EBT reactor proof-of-principle device operated with a deuterium-tritium plasma. Sensitivity studies were performed for variation in the input microwave power sharing fractions and the dependence of the bulk n tau scaling law on bulk electron temperature

  8. A Phospholipidomic Analysis of All Defined Human Plasma Lipoproteins

    Science.gov (United States)

    Dashti, Monireh; Kulik, Willem; Hoek, Frans; Veerman, Enno C.; Peppelenbosch, Maikel P.; Rezaee, Farhad

    2011-01-01

    Since plasma lipoproteins contain both protein and phospholipid components, either may be involved in processes such as atherosclerosis. In this study the identification of plasma lipoprotein-associated phospholipids, which is essential for understanding these processes at the molecular level, are performed. LC-ESI/MS, LC-ESI-MS/MS and High Performance Thin Layer Chromatography (HPTLC) analysis of different lipoprotein fractions collected from pooled plasma revealed the presence of phosphatidylethanolamine (PE), phosphatidylinositol (PI), and sphingomyeline (SM) only on lipoproteins and phosphatidylcholine (PC), Lyso-PC on both lipoproteins and plasma lipoprotein free fraction (PLFF). Cardiolipin, phosphatidylglycerol (PG) and Phosphatidylserine (PS) were observed neither in the lipoprotein fractions nor in PLFF. All three approaches led to the same results regarding phospholipids occurrence in plasma lipoproteins and PLFF. A high abundancy of PE and SM was observed in VLDL and LDL fractions respectively. This study provides for the first time the knowledge about the phospholipid composition of all defined plasma lipoproteins. PMID:22355656

  9. The baking analysis for vacuum vessel and plasma facing components of the KSTAR tokamak

    International Nuclear Information System (INIS)

    Lee, K. H.; Woo, H. K.; Im, K. H.; Cho, S. Y.; Kim, J. B.

    2000-01-01

    The base pressure of vacuum vessel of the KSTAR (Korea Superconducting Tokamak Advanced Research) Tokamak is to be a ultra high vacuum, 10 -6 ∼10 -7 Pa, to produce clean plasma with low impurity containments. For this purpose, the KSTAR vacuum vessel and plasma facing components need to be baked up to at least 250 .deg. C, 350 .deg. C respectively, within 24 hours by hot nitrogen gas from a separate baking/cooling line system to remove impurities from the plasma-material interaction surfaces before plasma operation. Here by applying the implicit numerical method to the heat balance equations of the system, overall temperature distributions of the KSTAR vacuum vessel and plasma facing components are obtained during the whole baking process. The model for 2-dimensional baking analysis are segmented into 9 imaginary sectors corresponding to each plasma facing component and has up-down symmetry. Under the resulting combined loads including dead weight, baking gas pressure, vacuum pressure and thermal loads, thermal stresses in the vacuum vessel during bakeout are calculated by using the ANSYS code. It is found that the vacuum vessel and its supports are structurally rigid based on the thermal stress analyses

  10. The baking analysis for vacuum vessel and plasma facing components of the KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K. H.; Woo, H. K. [Chungnam National Univ., Taejon (Korea, Republic of); Im, K. H.; Cho, S. Y. [korea Basic Science Institute, Taejon (Korea, Republic of); Kim, J. B. [Hyundai Heavy Industries Co., Ltd., Ulsan (Korea, Republic of)

    2000-07-01

    The base pressure of vacuum vessel of the KSTAR (Korea Superconducting Tokamak Advanced Research) Tokamak is to be a ultra high vacuum, 10{sup -6}{approx}10{sup -7}Pa, to produce clean plasma with low impurity containments. For this purpose, the KSTAR vacuum vessel and plasma facing components need to be baked up to at least 250 .deg. C, 350 .deg. C respectively, within 24 hours by hot nitrogen gas from a separate baking/cooling line system to remove impurities from the plasma-material interaction surfaces before plasma operation. Here by applying the implicit numerical method to the heat balance equations of the system, overall temperature distributions of the KSTAR vacuum vessel and plasma facing components are obtained during the whole baking process. The model for 2-dimensional baking analysis are segmented into 9 imaginary sectors corresponding to each plasma facing component and has up-down symmetry. Under the resulting combined loads including dead weight, baking gas pressure, vacuum pressure and thermal loads, thermal stresses in the vacuum vessel during bakeout are calculated by using the ANSYS code. It is found that the vacuum vessel and its supports are structurally rigid based on the thermal stress analyses.

  11. Multifractal analysis of plasma turbulence in biasing experiments on Castor tokamak

    Czech Academy of Sciences Publication Activity Database

    Budaev, V.P.; Dufková, Edita; Nanobashvili, S.; Weinzettl, Vladimír; Zajac, Jaromír

    2005-01-01

    Roč. 55, C (2005), s. 1615-1621 ISSN 0011-4626. [Workshop “Electric Fields, Structures and Relaxation in Edge Plasmas". Tarragona, 5.7.2005-5.7.2005] Institutional research plan: CEZ:AV0Z20430508 Keywords : plasma turbulence * multifractal analysis Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.360, year: 2005

  12. Nonlinear Electrostatic Wave Equations for Magnetized Plasmas

    DEFF Research Database (Denmark)

    Dysthe, K.B.; Mjølhus, E.; Pécseli, Hans

    1984-01-01

    The lowest order kinetic effects are included in the equations for nonlinear electrostatic electron waves in a magnetized plasma. The modifications of the authors' previous analysis based on a fluid model are discussed.......The lowest order kinetic effects are included in the equations for nonlinear electrostatic electron waves in a magnetized plasma. The modifications of the authors' previous analysis based on a fluid model are discussed....

  13. Dusty Plasma Modeling of the Fusion Reactor Sheath Including Collisional-Radiative Effects

    International Nuclear Information System (INIS)

    Dezairi, Aouatif; Samir, Mhamed; Eddahby, Mohamed; Saifaoui, Dennoun; Katsonis, Konstantinos; Berenguer, Chloe

    2008-01-01

    The structure and the behavior of the sheath in Tokamak collisional plasmas has been studied. The sheath is modeled taking into account the presence of the dust 2 and the effects of the charged particle collisions and radiative processes. The latter may allow for optical diagnostics of the plasma.

  14. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  15. Plasma properties

    International Nuclear Information System (INIS)

    Weitzner, H.

    1991-06-01

    The Magneto-Fluid Dynamics Division continues to study a broad range of problems originating in plasma physics. Its principal focus is fusion plasma physics, and most particularly topics of particular significance for the world magnetic fusion program. During the calendar year 1990 we explored a wide range of topics including RF-induced transport as a plasma control mechanism, edge plasma modelling, further statistical analysis of L and H mode tokamak plasmas, antenna design, simulation of the edge of a tokamak plasma and the L-H transition, interpretation of the CCT experimental results at UCLA, turbulent transport, studies in chaos, the validity of moment approximations to kinetic equations and improved neoclassical modelling. In more basic studies we examined the statistical mechanisms of Coulomb systems and applied plasma ballooning mode theory to conventional fluids in order to obtain novel fluid dynamics stability results. In space plasma physics we examined the problem of reconnection, the effect of Alfven waves in space environments, and correct formulation of boundary conditions of the Earth for waves in the ionosphere

  16. Laser induced breakdown spectroscopy of the uranium including calcium. Time resolved measurement spectroscopic analysis (Contract research)

    International Nuclear Information System (INIS)

    Akaoka, Katsuaki; Maruyama, Youichiro; Oba, Masaki; Miyabe, Masabumi; Otobe, Haruyoshi; Wakaida, Ikuo

    2010-05-01

    For the remote analysis of low DF TRU (Decontamination Factor Transuranic) fuel, Laser Breakdown Spectroscopy (LIBS) was applied to uranium oxide including a small amount of calcium oxide. The characteristics, such as spectrum intensity and plasma excitation temperature, were measured using time-resolved spectroscopy. As a result, in order to obtain the stable intensity of calcium spectrum for the uranium spectrum, it was found out that the optimum observation delay time of spectrum is 4 microseconds or more after laser irradiation. (author)

  17. Experimental investigation of plasma relaxation using a compact coaxial magnetized plasma gun in a background plasma

    Science.gov (United States)

    Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott; University of New Mexico Collaboration; Los Alamos National Laboratory Collaboration

    2013-10-01

    A compact coaxial plasma gun is employed for experimental studies of plasma relaxation in a low density background plasma. Experiments are being conducted in the linear HelCat device at UNM. These studies will advance the knowledge of basic plasma physics in the areas of magnetic relaxation and space and astrophysical plasmas, including the evolution of active galactic jets/radio lobes within the intergalactic medium. The gun is powered by a 120pF ignitron-switched capacitor bank which is operated in a range of 5-10 kV and ~100 kA. Multiple diagnostics are employed to investigate plasma relaxation process. Magnetized Argon plasma bubbles with velocities ~1.2Cs and densities ~1020 m-3 have been achieved. Different distinct regimes of operation with qualitatively different dynamics are identified by fast CCD camera images, with the parameter determining the operation regime. Additionally, a B-dot probe array is employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify detached plasma bubble configurations. Experimental data and analysis will be presented.

  18. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  19. Analysis of plasma equilibrium based on orbit-driven current density profile in steady-state plasma on QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, K., E-mail: nakamura@triam.kyushu-u.ac.jp [RIAM, Kyushu University, Kasuga 816-8580 (Japan); Alam, M.M. [IGSES, Kyushu University, Kasuga 816-8580 (Japan); Jiang, Y.Z. [Tsinghua University, Beijing 100084 (China); Mitarai, O. [Tokai University, Kumamoto 862-8652 (Japan); Kurihara, K.; Kawamata, Y.; Sueoka, M.; Takechi, M. [Japan Atomic Energy Agency, Naka 311-0193 (Japan); Hasegawa, M.; Tokunaga, K.; Araki, K.; Zushi, H.; Hanada, K.; Fujisawa, A.; Idei, H.; Nagashima, Y.; Kawasaki, S.; Nakashima, H.; Higashijima, A.; Nagata, T. [RIAM, Kyushu University, Kasuga 816-8580 (Japan); and others

    2016-11-01

    Highlights: • High energy particle guiding center orbit is calculated as a contour plot of conserved variable. • Current density profile is analyzed based on the orbit-driven current. • Plasma equilibrium is reconstructed by considering the hollow current profile. - Abstract: In the present RF-driven (ECCD) steady-state plasma on QUEST (B{sub t} = 0.25 T, R = 0.68 m, a = 0.40 m), plasma current seems to flow in the open magnetic surface outside of the closed magnetic surface in the low-field region according to plasma current fitting (PCF) method. We consider that the current in the open magnetic surface is due to orbit-driven current by high-energy particles in RF-driven plasma. So based on the analysis of current density profile based on the orbit-driven current, plasma equilibrium is to be calculated. We calculated high energy particles guiding center orbits as a contour plot of conserved variable in Hamiltonian formulation and considered particles initial position with different levels of energy and pitch angles that satisfy resonance condition. Then the profile of orbit-driven current is estimated by multiplying the particle density on the resonance surface and the velocity on the orbits. This analysis shows negative current near the magnetic axis and hollow current profile is expected even if pressure driven current is considered. Considering the hollow current profile shifted toward the low-field region, the equilibrium is fitted by J-EFIT coded by MATLAB.

  20. RACLETTE: a model for evaluating the thermal response of plasma facing components to slow high power plasma transients. Pt. II. Analysis of ITER plasma facing components

    International Nuclear Information System (INIS)

    Federici, G.; Raffray, A.R.

    1997-01-01

    For pt.I see ibid., p.85-100, 1997. The transient thermal model RACLETTE (acronym of Rate Analysis Code for pLasma Energy Transfer Transient Evaluation) described in part I of this paper is applied here to analyse the heat transfer and erosion effects of various slow (100 ms-10 s) high power energy transients on the actively cooled plasma facing components (PFCs) of the International Thermonuclear Experimental Reactor (ITER). These have a strong bearing on the PFC design and need careful analysis. The relevant parameters affecting the heat transfer during the plasma excursions are established. The temperature variation with time and space is evaluated together with the extent of vaporisation and melting (the latter only for metals) for the different candidate armour materials considered for the design (i.e., Be for the primary first wall, Be and CFCs for the limiter, Be, W, and CFCs for the divertor plates) and including for certain cases low-density vapour shielding effects. The critical heat flux, the change of the coolant parameters and the possible severe degradation of the coolant heat removal capability that could result under certain conditions during these transients, for example for the limiter, are also evaluated. Based on the results, the design implications on the heat removal performance and erosion damage of the various ITER PFCs are critically discussed and some recommendations are made for the selection of the most adequate protection materials and optimum armour thickness. (orig.)

  1. Process simulation and uncertainty analysis of plasma arc mixed waste treatment

    International Nuclear Information System (INIS)

    Ferrada, J.J.; Welch, T.D.

    1994-01-01

    Innovative mixed waste treatment subsystems have been analyzed for performance, risk, and life-cycle cost as part of the U.S. Department of Energy's (DOE)'s Mixed Waste Integrated Program (MWIP) treatment alternatives development and evaluation process. This paper concerns the analysis of mixed waste treatment system performance. Performance systems analysis includes approximate material and energy balances and assessments of operability, effectiveness, and reliability. Preliminary material and energy balances of innovative processes have been analyzed using FLOW, an object-oriented, process simulator for waste management systems under development at Oak Ridge National Laboratory. The preliminary models developed for FLOW provide rough order-of-magnitude calculations useful for sensitivity analysis. The insight gained from early modeling of these technologies approximately will ease the transition to more sophisticated simulators as adequate performance and property data become available. Such models are being developed in ASPEN by DOE's Mixed Waste Treatment Project (MWTP) for baseline and alternative flow sheets based on commercial technologies. One alternative to the baseline developed by the MWIP support groups in plasma arc treatment. This process offers a noticeable reduction in the number of process operations as compared to the baseline process because a plasma arc melter is capable of accepting a wide variety of waste streams as direct inputs (without sorting or preprocessing). This innovative process for treating mixed waste replaces several units from the baseline process and, thus, promises an economic advantage. The performance in the plasma arc furnace will directly affect the quality of the waste form and the requirements of the off-gas treatment units. The ultimate objective of MWIP is to reduce the amount of final waste produced, the cost, and the environmental impact

  2. Equilibrium and linear analysis of rotating plasmas: fluid and guiding center results

    International Nuclear Information System (INIS)

    Iacono, R.

    1990-06-01

    This work is devoted to the equilibrium and stability of rotating plasmas. Apart from its theoretical interest, this subject has become of practical importance in fusion research, due to the use in recent tokamak experiments of auxiliary heating methods such as neutral-beam injection, which can produce large plasma flows. Flow velocities up to the ion sound speed have been measured on different machines and new phenomena associated with the flow, such as distorsions of the plasma equilibrium profiles, have been observed. As a consequence, flows must be included in the macroscopic description of plasma equilibrium, which is the basis for the analysis and the design of magnetic confinement machines, and the stability properties of equilibria with flows need to be investigated. Here, attention is centered on toroidal confinement machines and in particular on tokamaks. However, some of the results to be presented may be of interest also for other domains (strong mass flows also occur in astrophysical and geophysical contexts such as in the Jovian magnetosphere or in the Earth's magnetopause and plasmapause. It should be noted that equilibrium and, in particular, stability with flows are poorly understood at present. Therefore, many of the questions we will consider are of quite a general nature. We are not yet at the point where quantitative comparisons with specific experiments can be made. Even the choice of a convenient model to study plasma flow is far from being evident. So far most of the theoretical investigations have used the magnetohydrodynamic (MHD) model, which is one of the simplest descriptions of a plasma. In this work, however, it will be shown that, for rotating plasmas, the 'simple' MHD model can give very complicated and physically meaningless results, while more 'complicated' models can provide a simpler and more realistic description of the plasma behaviour. 65 refs., 8 figs., 3 tabs

  3. Time resolved two- and three-dimensional plasma diagnostics

    International Nuclear Information System (INIS)

    1991-03-01

    This collection of papers on diagnostics in fusion plasmas contains work on the data analysis of inverse problems and on the experimental arrangements presently used to obtain spatially and temporally resolved plasma radial profiles, including electron and ion temperature, plasma density and plasma current profiles. Refs, figs and tabs

  4. Analysis of plasma dynamic response to modulated electron cyclotron heating in TCV tokamak

    International Nuclear Information System (INIS)

    Pavlov, I.

    2008-01-01

    different types of modulating signals. This set-up was used to study simultaneous propagation of heat waves induced by MECH in non-sawtoothing plasmas, and in discharges with sawtooth activity. A new analysis method for the characterization of the plasma non-linear dynamic response to modulated heating was developed on the basis of Higher Order Spectral Analysis (HOSA) technique. This method applied to signals from different diagnostics, such as electron cyclotron emission and soft X-ray measurements, was extensively used to quantitatively characterize the effect of nonlinear phase coupling. In sawtooth free discharges a detailed analysis of the propagation of heat waves demonstrated that their phase coupling is solely related to properties of heat sources. It was demonstrated that if two heat waves are induced by non-coupled power sources (multi-beam MECH) then no phase coupling occurs. In the opposite case, when a source of perturbation (MECH) contains coupled harmonics, the corresponding heat waves demonstrate phase coupling. It was shown that these coupled heat waves loose their phase coherence while propagating in plasma. The dissipation of phase coupling is due to different phase velocities of heat waves and their diffusive damping. The new type of ECH power modulation accompanied with bicoherence analysis was proposed as a candidate for a reliable identification of EC power deposition location in a case of high frequency and low modulation depth MECH, including multi-beam heating. This type of MECH can be particularly important for real time control applications. In cases when MECH is applied to sawtoothing plasmas a direct experimental evidence of MECH-sawtooth non-linear phase coupling has been demonstrated using HOSA techniques, in particular bispectrum and bicoherence profiles. The detailed analysis presented here demonstrates a direct proof of periodic modification of sawtooth behavior by modulated ECH. It was shown that a simple diffusive model for the

  5. The baking analysis for vacuum vessel and plasma facing components of the KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.H. [Chungnam National University Graduate School, Taejeon (Korea); Im, K.H.; Cho, S.Y. [Korea Basic Science Institute, Taejeon (Korea); Kim, J.B. [Hyundai Heavy Industries Co., Ltd. (Korea); Woo, H.K. [Chungnam National University, Taejeon (Korea)

    2000-11-01

    The base pressure of vacuum vessel of the KSTAR (Korea Superconducting Tokamak Advanced Research) Tokamak is to be a ultra high vacuum, 10{sup -6} {approx} 10{sup -7} Pa, to produce clean plasma with low impurity containments. for this purpose, the KSTAR vacuum vessel and plasma facing components need to be baked up to at least 250 deg.C, 350 deg.C respectively, within 24 hours by hot nitrogen gas from a separate baking/cooling line system to remove impurities from the plasma-material interaction surfaces before plasma operation. Here by applying the implicit numerical method to the heat balance equations of the system, overall temperature distributions of the KSTAR vacuum vessel and plasma facing components are obtained during the whole baking process. The model for 2-dimensional baking analysis are segmented into 9 imaginary sectors corresponding to each plasma facing component and has up-down symmetry. Under the resulting combined loads including dead weight, baking gas pressure, vacuum pressure and thermal loads, thermal stresses in the vacuum vessel during bakeout are calculated by using the ANSYS code. It is found that the vacuum vessel and its supports are structurally rigid based on the thermal stress analyses. (author). 9 refs., 11 figs., 1 tab.

  6. Extended standard vector analysis for plasma physics

    International Nuclear Information System (INIS)

    Wimmel, H.K.

    1982-02-01

    Standard vector analysis in 3-dimensional space, as found in most tables and textbooks, is complemented by a number of basic formulas that seem to be largely unknown, but are important in themselves and for some plasma physics applications, as is shown by several examples. (orig.)

  7. Application of a plasma-jet for skin antisepsis: analysis of the thermal action of the plasma by laser scanning microscopy

    International Nuclear Information System (INIS)

    Lademann, O; Kramer, A; Richter, H; Patzelt, A; Alborova, A; Humme, D; Weltmann, K-D; Hartmann, B; Hinz, P; Koch, S

    2010-01-01

    Recently, it was reported that a plasma-jet could be efficiently applied for the antisepsis of wounds. In this case, the discharge in an argon gas stream was used to produce a so-called ''cold plasma'' on the skin surface. The thermal action of the plasma on the skin was investigated in the present study by means of laser scanning microscopy (LSM) and by histological analysis. Consequently, the plasma beam was moved with a definite velocity at an optimal distance over the skin surface. The structural changes of the tissue were analyzed. It was found by LSM that a thermal damage could be detected only in the upper cell layers of the stratum corneum (SC) at moving velocities of the plasma beam, usually applied in clinical practice. Deeper parts of the SC were not damaged. The structural changes were so superficial that they could be detected only by LSM but not by analysis of the histological sections

  8. Plasma ET-1 Concentrations are Elevated in Patients with Hypertension - Meta-Analysis of Clinical Studies.

    Science.gov (United States)

    Xu, Mei; Lu, Yong-Ping; Hasan, Ahmed Abdallah; Hocher, Berthold

    2017-01-01

    A recent study revealed that global overexpression of ET-1 causes a slight reduction in systemic blood pressure. Moreover, heterozygous ET-1 knockout mice are hypertensive. The role of ET-1 in human hypertension was so far not addressed by a strict meta-analysis of published human clinical studies. We included studies published between January 1, 1990 and February 28, 2017. We included case control studies analyzing untreated essential hypertension or hypertensive patients where antihypertensive medication was discontinued for at least two weeks. Based on the principle of Cochrane systematic reviews, case control studies (CCSs) in PubMed (Medline) and Google Scholar designed to identify the role of endothelin-1 (ET-1) in the pathophysiological of hypertension were screened. Review Manager Version 5.0 (Rev-Man 5.0) was applied for statistical analysis. Mean difference and 95% confidence interval (CI) were shown in inverse variance (IV) fixed-effects model or IV random-effects models. Eleven studies fulfilling our in- and exclusion criteria were eligible for this meta-analysis. These studies included 450 hypertensive patients and 328 controls. Our meta-analysis revealed that ET-1 plasma concentrations were higher in hypertensive patients as compared to the control patients [mean difference between groups 1.57 pg/mL, 95%CI [0.47∼2.68, P = 0.005]. These finding were driven by patients having systolic blood pressure higher than 160 mmHg and diastolic blood pressure higher than 100 mmHg. This meta-analysis showed that hypertensive patients do have elevated plasma ET-1 concentrations. This finding is driven by those patients with high systolic/diastolic blood pressure. Given that the ET-1 gene did not appear in any of the whole genome association studies searching for hypertension associated gene loci, it is very likely that the elevated plasma ET-1 concentrations in hypertensive patients are secondary to hypertension and may reflect endothelial cell damage. © 2017 The

  9. A full-angle Monte-Carlo scattering technique including cumulative and single-event Rutherford scattering in plasmas

    Science.gov (United States)

    Higginson, Drew P.

    2017-11-01

    We describe and justify a full-angle scattering (FAS) method to faithfully reproduce the accumulated differential angular Rutherford scattering probability distribution function (pdf) of particles in a plasma. The FAS method splits the scattering events into two regions. At small angles it is described by cumulative scattering events resulting, via the central limit theorem, in a Gaussian-like pdf; at larger angles it is described by single-event scatters and retains a pdf that follows the form of the Rutherford differential cross-section. The FAS method is verified using discrete Monte-Carlo scattering simulations run at small timesteps to include each individual scattering event. We identify the FAS regime of interest as where the ratio of temporal/spatial scale-of-interest to slowing-down time/length is from 10-3 to 0.3-0.7; the upper limit corresponds to Coulomb logarithm of 20-2, respectively. Two test problems, high-velocity interpenetrating plasma flows and keV-temperature ion equilibration, are used to highlight systems where including FAS is important to capture relevant physics.

  10. Versatile software for semiautomatic analysis and processing of laser-induced plasma spectra

    International Nuclear Information System (INIS)

    Mateo, M.P.; Nicolas, G.; Pinon, V.; Alvarez, J.C.; Ramil, A.; Yanez, A.

    2005-01-01

    The present article describes the main characteristics and operations of SALIPS (software for the analysis of laser-induced plasma spectra), a computer program designed for use in Spectroscopy. During the last years laser-induced plasma spectroscopy (LIPS) has grown in popularity and different applications have been developed in several fields. However, until now there is no software reported to perform the recognition of the elemental composition of a generic sample from its LIP spectrum, which must be achieved by hand in a tedious comparative process of experimental peaks with emission lines from databases. For this reason, a computer program that includes several tools to provide a semi-automatic identification of the peaks of a LIP spectrum has been developed. The program, written in Microsoft registered Visual Basic registered code, has a user-friendly graphical interface and is a flexible tool that enables to handle, edit, copy and print a quick presentation of the data including automatically the identification results in the graph. SALIPS also provides some physical properties of the elements and includes algorithms for performing the simulation of spectra. The potential of the program is illustrated with some examples

  11. Two dimensional neutral transport analysis in tokamak plasma

    International Nuclear Information System (INIS)

    Shimizu, Katsuhiro; Azumi, Masafumi

    1987-02-01

    Neutral particle influences the particle and energy balance, and play an important role on sputtering impurity and the charge exchange loss of neutral beam injection. In order to study neutral particle behaviour including the effects of asymmetric source and divertor configuration, the two dimensional neutral transport code has been developed using the Monte-Carlo techniques. This code includes the calculation of the H α radiation intensity based on the collisional-radiation model. The particle confinement time of the joule heated plasma in JT-60 tokamak is evaluated by comparing the calculated H α radiation intensity with the experimental data. The effect of the equilibrium on the neutral density profile in high-β plasma is also investigated. (author)

  12. EDITORIAL: Plasma jets and plasma bullets Plasma jets and plasma bullets

    Science.gov (United States)

    Kong, M. G.; Ganguly, B. N.; Hicks, R. F.

    2012-06-01

    technological solution in the early to late 1990s of confining atmospheric plasmas in a small volume of plasma generation (i.e. with a small volume-to-surface ratio) and then extending it towards a downstream sample [7]-[9]. These are among the first low-temperature atmospheric plasmas aimed particularly at the exploitation of their ability to invoke the active and rich reactive chemistry close to ambient temperature. The main applications of these early devices are precision surface modification of low-temperature dielectric materials, for example thin film deposition and etching [7]-[9]. Variations of the early plasma jets include atmospheric plasma sheet jets [10] for the treatment of largely planar objects (e.g. polymeric sheets) as well as large arrays of many plasma jets for the treatment of complex-structured objects (e.g. surgical tools and open human wounds) [11]. As a material processing technology, the sub-100oC atmospheric-pressure plasma jet has benefited over the years from many innovations. Whilst a detailed account and analysis of these is clearly outside the scope of this Editorial, it is worth stating that there are different avenues with which to maintain a moderate electron density at the plasma core so as to keep the gas temperature at the sample point below a ceiling level. Most of the early studies employed excitation at radio frequencies above 10 MHz, at which electrons are largely confined in the plasma generation region, and this limits the current flow to and gas heating in the plume region of the plasma jet. Other techniques of current limitation have since been shown to be effective, including the use of dielectric barriers across a very large frequency range of 1 kHz--50 MHz, sub-microsecond pulses sustained at kHz frequencies, pulse-modulated radio frequencies and dual-frequency excitation [12]-[15]. These and other techniques have considerably advanced the atmospheric-pressure plasma jet technology. The period of some 15 years since the above

  13. Atmospheric pressure plasma analysis by modulated molecular beam mass spectrometry

    NARCIS (Netherlands)

    Aranda Gonzalvo, Y.; Whitmore, T.D.; Rees, J.A.; Seymour, D.L.; Stoffels - Adamowicz, E.

    2006-01-01

    Fractional no. d. measurements for a radiofrequency plasma needle operating at atm. pressure were obtained using a mol. beam mass spectrometer (MBMS) system designed for diagnostics of atm. plasmas. The MBMS system comprises three differentially pumped stages and a mass/energy analyzer and includes

  14. ITER plasma facing components

    International Nuclear Information System (INIS)

    Kuroda, T.; Vieider, G.; Akiba, M.

    1991-01-01

    This document summarizes results of the Conceptual Design Activities (1988-1990) for the International Thermonuclear Experimental Reactor (ITER) project, namely those that pertain to the plasma facing components of the reactor vessel, of which the main components are the first wall and the divertor plates. After an introduction and an executive summary, the principal functions of the plasma-facing components are delineated, i.e., (i) define the low-impurity region within which the plasma is produced, (ii) absorb the electromagnetic radiation and charged-particle flux from the plasma, and (iii) protect the blanket/shield components from the plasma. A list of critical design issues for the divertor plates and the first wall is given, followed by discussions of the divertor plate design (including the issues of material selection, erosion lifetime, design concepts, thermal and mechanical analysis, operating limits and overall lifetime, tritium inventory, baking and conditioning, safety analysis, manufacture and testing, and advanced divertor concepts) and the first wall design (armor material and design, erosion lifetime, overall design concepts, thermal and mechanical analysis, lifetime and operating limits, tritium inventory, baking and conditioning, safety analysis, manufacture and testing, an alternative first wall design, and the limiters used instead of the divertor plates during start-up). Refs, figs and tabs

  15. Analysis of the expanding thermal argon-oxygen plasma gas phase

    International Nuclear Information System (INIS)

    Hest, M F A M van; Haartsen, J R; Weert, M H M van; Schram, D C; Sanden, M C M van de

    2003-01-01

    An expanding thermal argon plasma into which oxygen is injected has been analysed by means of Langmuir and Pitot probe measurements. Information is obtained on the ion density profile and the flow pattern in the downstream plasma. A combination of Langmuir and Pitot probe measurements provide information on the total ion flux generated by the plasma source (cascaded arc). It has been found that the ion diffusion is mainly determined by the background pressure in the expansion vessel and the arc current. The ion density is determined by the total power input into the plasma as well as the gas flow in the plasma source. There is an optimum in the power transfer used for ionization from plasma source to the feed gas. Interaction of oxygen with the plasma results in a decrease in the argon ion density and the plasma beam radius. The recirculation pattern of the downstream plasma has been investigated experimentally using the Pitot probe. Due to the low downstream pressure (10-30 Pa), the conventional compressible Pitot probe theory no longer applies. It is concluded that viscous effects start to play an important role at these low pressures and should be taken into account in the analysis of the Pitot probe measurements

  16. Plasma characterization using ultraviolet Thomson scattering from ion-acoustic and electron plasma waves (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Follett, R. K., E-mail: rfollett@lle.rochester.edu; Delettrez, J. A.; Edgell, D. H.; Henchen, R. J.; Katz, J.; Myatt, J. F.; Froula, D. H. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623 (United States)

    2016-11-15

    Collective Thomson scattering is a technique for measuring the plasma conditions in laser-plasma experiments. Simultaneous measurements of ion-acoustic and electron plasma-wave spectra were obtained using a 263.25-nm Thomson-scattering probe beam. A fully reflective collection system was used to record light scattered from electron plasma waves at electron densities greater than 10{sup 21} cm{sup −3}, which produced scattering peaks near 200 nm. An accurate analysis of the experimental Thomson-scattering spectra required accounting for plasma gradients, instrument sensitivity, optical effects, and background radiation. Practical techniques for including these effects when fitting Thomson-scattering spectra are presented and applied to the measured spectra to show the improvements in plasma characterization.

  17. Magnetic analysis including the field due to vacuum vessel eddy currents in the Hitachi Tokamak (HT-2)

    International Nuclear Information System (INIS)

    Abe, Mitsushi; Takeuchi, Kazuhiro; Fukumoto, Hideshi; Otsuka, Michio

    1989-01-01

    A magnetic analysis to determine plasma surface position is applied to the magnetic data of the Hitachi Tokamak (HT-2). The analysis takes account of toroidal eddy currents on the vacuum vessel wall. Magnetic probes in HT-2 are placed on both sides of the wall (plasma side and outside), making it possible to determine magnitudes of eddy currents which flow in the toroidal direction. The magnitudes of the coil currents and eddy currents are determined so as to reproduce the measured magnetic fields, and to reconstruct flux surfaces and plasma surface are reconstructed. Taking into account the eddy currents, the determination errors of the plasma surface position are reduced by up to 1/2.3 during start-up and terminating phases, compared with the case without eddy currents. (author)

  18. Fluorogenic MMP activity assay for plasma including MMPs complexed to α2-macroglobulin

    NARCIS (Netherlands)

    Beekman, B.; Drijfhout, J.W.; Ronday, H.K.; TeKoppele, J.M.

    1999-01-01

    Elevated MMP activities are implicated in tissue degradation in, e.g., arthritis and cancer. The present study was designed to measure MMP enzyme activity in plasma. Free active MMP is unlikely to be present in plasma: upon entering the circulation, active MMP is expected to be captured by the

  19. Enrichment and proteomic analysis of plasma membrane from rat dorsal root ganglions

    Directory of Open Access Journals (Sweden)

    Lin Yong

    2009-11-01

    Full Text Available Abstract Background Dorsal root ganglion (DRG neurons are primary sensory neurons that conduct neuronal impulses related to pain, touch and temperature senses. Plasma membrane (PM of DRG cells plays important roles in their functions. PM proteins are main performers of the functions. However, mainly due to the very low amount of DRG that leads to the difficulties in PM sample collection, few proteomic analyses on the PM have been reported and it is a subject that demands further investigation. Results By using aqueous polymer two-phase partition in combination with high salt and high pH washing, PMs were efficiently enriched, demonstrated by western blot analysis. A total of 954 non-redundant proteins were identified from the plasma membrane-enriched preparation with CapLC-MS/MS analysis subsequent to protein separation by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE or shotgun digestion. 205 (21.5% of the identified proteins were unambiguously assigned as PM proteins, including a large number of signal proteins, receptors, ion channel and transporters. Conclusion The aqueous polymer two-phase partition is a simple, rapid and relatively inexpensive method. It is well suitable for the purification of PMs from small amount of tissues. Therefore, it is reasonable for the DRG PM to be enriched by using aqueous two-phase partition as a preferred method. Proteomic analysis showed that DRG PM was rich in proteins involved in the fundamental biological processes including material exchange, energy transformation and information transmission, etc. These data would help to our further understanding of the fundamental DRG functions.

  20. Electromagnetic analysis of ITER diagnostic equatorial port plugs during plasma disruptions

    International Nuclear Information System (INIS)

    Zhai, Y.; Feder, R.; Brooks, A.; Ulrickson, M.; Pitcher, C.S.; Loesser, G.D.

    2013-01-01

    Highlights: ► Disruption loads on ITER diagnostic equatorial port plugs are extracted. ► Upward major disruption produces the largest radial moment and radial force on diagnostic first walls and diagnostic shield modules. ► Large eddy currents on supporting rails, keys and water pipes are observed during disruption. -- Abstract: ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the diagnostic first walls (DFWs), diagnostic shield modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed

  1. Sulfur analysis by inductively coupled plasma-mass spectrometry: A review

    Energy Technology Data Exchange (ETDEWEB)

    Giner Martínez-Sierra, J.; Galilea San Blas, O.; Marchante Gayón, J.M.; García Alonso, J.I., E-mail: jiga@uniovi.es

    2015-06-01

    In recent years the number of applications of sulfur (S) analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. In this article we describe in some depth the application of ICP-MS for S analysis with emphasis placed on the sulfur-specific detection by hyphenated techniques such as LC, GC, CE and LA coupled on-line to ICP-MS. The different approaches available for sulfur isotope ratio measurements by ICP-MS are also detailed. Particular attention has been paid to the quantification of peptides/proteins and the analysis of metallopeptides/metalloproteins via sulfur by LC–ICP-MS. Likewise, the speciation analysis of metal-based pharmaceuticals and metallodrugs and non-metal selective detection of pharmaceuticals via S are highlighted. Labeling procedures for metabolic applications are also included. Finally, the measurement of natural variations in S isotope composition with multicollector ICP-MS instruments is also covered in this review. - Highlights: • Emphasis placed on the sulfur-specific detection by chromatographic techniques coupled on-line to ICP-MS. • Different instrumental approaches available for sulfur measurements by ICP-MS. • Quantification of proteins and the analysis of metalloproteins via sulfur by LC-ICP-MS. • Labelling procedures for metabolic applications are also included. • The measurement of natural variations in S isotope composition with multicollector ICP-MS.

  2. Discriminant analysis of plasma fusion data

    International Nuclear Information System (INIS)

    Kardaun, O.J.W.F.; Kardaun, J.W.P.F.; Itoh, S.; Itoh, K.

    1992-06-01

    Several discriminant analysis methods has been applied and compared to predict the type of ELM's in H-mode discharges: (a) quadratic discriminant analysis (linear discriminant analysis being a special case), (b) discrimination by non-parametric (kernel-) density estimates, and (c) discrimination by a product multinomial model on a discretised scale. Practical evaluation was performed using SAS in the first two cases, and INDEP, a standard FORTRAN program, initially developed for medical applications, in the last case. We give here a flavour of the approach and its results. In summary, discriminant analysis can be used as a useful descriptive method of specifying regions where particular types of plasma discharges can be produced. Parametric methods have the advantage of a rather compact mathematical formulation . Pertinent graphical representations are useful to make the theory and the results more palatable to the experimental physicists. (J.P.N.)

  3. Consensus guidelines on plasma cell myeloma minimal residual disease analysis and reporting.

    Science.gov (United States)

    Arroz, Maria; Came, Neil; Lin, Pei; Chen, Weina; Yuan, Constance; Lagoo, Anand; Monreal, Mariela; de Tute, Ruth; Vergilio, Jo-Anne; Rawstron, Andy C; Paiva, Bruno

    2016-01-01

    Major heterogeneity between laboratories in flow cytometry (FC) minimal residual disease (MRD) testing in multiple myeloma (MM) must be overcome. Cytometry societies such as the International Clinical Cytometry Society and the European Society for Clinical Cell Analysis recognize a strong need to establish minimally acceptable requirements and recommendations to perform such complex testing. A group of 11 flow cytometrists currently performing FC testing in MM using different instrumentation, panel designs (≥ 6-color) and analysis software compared the procedures between their respective laboratories and reviewed the literature to propose a consensus guideline on flow-MRD analysis and reporting in MM. Consensus guidelines support i) the use of minimum of five initial gating parameters (CD38, CD138, CD45, forward, and sideward light scatter) within the same aliquot for accurate identification of the total plasma cell compartment; ii) the analysis of potentially aberrant phenotypic markers and to report the antigen expression pattern on neoplastic plasma cells as being reduced, normal or increased, when compared to a normal reference plasma cell immunophenotype (obtained using the same instrument and parameters); and iii) the percentage of total bone marrow plasma cells plus the percentages of both normal and neoplastic plasma cells within the total bone marrow plasma cell compartment, and over total bone marrow cells. Consensus guidelines on minimal current and future MRD analyses should target a lower limit of detection of 0.001%, and ideally a limit of quantification of 0.001%, which requires at least 3 × 10(6) and 5 × 10(6) bone marrow cells to be measured, respectively. © 2015 International Clinical Cytometry Society.

  4. Plasma properties

    International Nuclear Information System (INIS)

    Weitzner, H.

    1990-06-01

    This paper discusses the following topics: MHD plasma activity: equilibrium, stability and transport; statistical analysis; transport studies; edge physics studies; wave propagation analysis; basic plasma physics and fluid dynamics; space plasma; and numerical methods

  5. Copper in Diabetes Mellitus: a Meta-Analysis and Systematic Review of Plasma and Serum Studies.

    Science.gov (United States)

    Qiu, Qihong; Zhang, Fuping; Zhu, Wenjun; Wu, Juan; Liang, Min

    2017-05-01

    Copper (Cu) is an important trace element involved in oxidative stress, which is associated with the onset and progression of diabetes mellitus (DM). However, clinical studies comparing plasma or serum Cu levels in patients with DM and in healthy individuals report conflicting findings. Therefore, in this meta-analysis, we analyzed the circulating levels of Cu associated with DM (including type 1 diabetes mellitus [T1DM] and type 2 diabetes mellitus [T2DM]). We searched the articles indexed in PubMed, OVID, and Cochrane databases, published through January 2016 and meeting our predefined criteria. Requisite data were extracted, and a random-effect model or a fixed-effect model was used to conduct the meta-analysis. Fifteen eligible studies involving a total of 1079 DM patients and 561 healthy controls were identified. Overall, the DM patients showed higher Cu levels than the healthy controls (plasma Cu mean difference [MD] = 1.69 μmol/L, p 1; serum Cu MD = 4.06 μmol/L, p = 0.005; plasma and serum Cu MD = 2.67 μmol/L, p = 0.006). Stratification based on the type of diabetes also indicated higher levels of Cu in the plasma and serum of DM patients than in healthy controls, respectively. Stratification of DM patients associated with and without complications also revealed similar results. This meta-analysis suggests that DM patients carried higher levels of Cu than healthy individuals. However, international cohort studies are needed to corroborate our findings.

  6. Superposed epoch analysis of pressure and magnetic field configuration changes in the plasma sheet

    International Nuclear Information System (INIS)

    Kistler, L.M.; Moebius, E.; Baumjohann, W.; Nagai, T.

    1993-01-01

    The authors report on an analysis of pressure and magnetic configuration within the plasma sheet following the initiation of substorm events. They have constructed this time dependent picture by using an epoch analysis of data from the AMPTE/IRM spacecraft. This analysis procedure can be used to construct a unified picture of events, provided they are reproducible, from a statistical analysis of a series of point measurements. The authors first determine the time dependent pressure changes in the plasma sheet. With some simplifying assumptions they then determine the z dependence of the pressure profiles, and from this distribution determine how field lines in the plasma sheet map to the neutral sheet

  7. Complex plasmas scientific challenges and technological opportunities

    CERN Document Server

    Lopez, Jose; Becker, Kurt; Thomsen, Hauke

    2014-01-01

    This book provides the reader with an introduction to the physics of complex plasmas, a discussion of the specific scientific and technical challenges they present, and an overview of their potential technological applications. Complex plasmas differ from conventional high-temperature plasmas in several ways: they may contain additional species, including nanometer- to micrometer-sized particles, negative ions, molecules and radicals, and they may exhibit strong correlations or quantum effects. This book introduces the classical and quantum mechanical approaches used to describe and simulate complex plasmas. It also covers some key experimental techniques used in the analysis of these plasmas, including calorimetric probe methods, IR absorption techniques and X-ray absorption spectroscopy. The final part of the book reviews the emerging applications of microcavity and microchannel plasmas, the synthesis and assembly of nanomaterials through plasma electrochemistry, the large-scale generation of ozone using mi...

  8. SO-FDTD analysis of anisotropic magnetized plasma

    International Nuclear Information System (INIS)

    Yang Hongwei; Nanjing Univ. of Science and Technology, Nanjing; Yuan Hong; Chen Rushan; Yang Yang

    2007-01-01

    A novel finite-difference time-domain (FDTD) method, called shift operator FDTD (SO-FDTD) method is developed for anisotropic magnetized dispersive media. The recursive relation between operators is used. In this paper, some expressions containing the dielectric constants of magnetized dispersive media are written as rational polynomial function. The SO-FDTD formulation for anisotropic magnetized plasma is derived. The high efficiency and effectiveness of the method are confirmed by computing the reflection and transmission through a magnetized plasma layer, with the direction of the propagation parallel to the direction of the biasing field. A comparison with frequency domain analytic results is included. The CPU time was several times shorter than that of the JEC method. (authors)

  9. Calibration strategy for semi-quantitative direct gas analysis using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Gerdes, Kirk; Carter, Kimberly E.

    2011-01-01

    A process is described by which an ICP-MS equipped with an Octopole Reaction System (ORS) is calibrated using liquid phase standards to facilitate direct analysis of gas phase samples. The instrument response to liquid phase standards is analyzed to produce empirical factors relating ion generation and transmission efficiencies to standard operating parameters. Empirical factors generated for liquid phase samples are then used to produce semi-quantitative analysis of both mixed liquid/gas samples and pure gas samples. The method developed is similar to the semi-quantitative analysis algorithms in the commercial software, which have here been expanded to include gas phase elements such as Xe and Kr. Equations for prediction of relative ionization efficiencies and isotopic transmission are developed for several combinations of plasma operating conditions, which allows adjustment of limited parameters between liquid and gas injection modes. In particular, the plasma temperature and electron density are calculated from comparison of experimental results to the predictions of the Saha equation. Comparisons between operating configurations are made to determine the robustness of the analysis to plasma conditions and instrument operating parameters. Using the methods described in this research, the elemental concentrations in a liquid standard containing 45 analytes and treated as an unknown sample were quantified accurately to ± 50% for most elements using 133 Cs as a single internal reference. The method is used to predict liquid phase mercury within 12% of the actual concentration and gas phase mercury within 28% of the actual concentration. The results verify that the calibration method facilitates accurate semi-quantitative, gas phase analysis of metal species with sufficient sensitivity to quantify metal concentrations lower than 1 ppb for many metallic analytes.

  10. Effect of Metformin on Plasma Fibrinogen Concentrations: A Systematic Review and Meta-Analysis of Randomized Placebo-Controlled Trials.

    Science.gov (United States)

    Simental-Mendia, Luis E; Pirro, Matteo; Atkin, Stephen L; Banach, Maciej; Mikhailidis, Dimitri P; Sahebkar, Amirhossein

    2018-01-01

    Fibrinogen is a key mediator of thrombosis and it has been implicated in the pathogenesis of atherosclerosis. Because metformin has shown a potential protective effect on different atherothrombotic risk factors, we assessed in this meta-analysis its effect on plasma fibrinogen concentrations. A systematic review and meta-analysis was carried out to identify randomized placebo-controlled trials evaluating the effect of metformin administration on fibrinogen levels. The search included PubMed-Medline, Scopus, ISI Web of Knowledge and Google Scholar databases (by June 2, 2017) and quality of studies was performed according to Cochrane criteria. Quantitative data synthesis was conducted using a random-effects model and sensitivity analysis by the leave-one-out method. Meta-regression analysis was performed to assess the modifiers of treatment response. Meta-analysis of data from 9 randomized placebo-controlled clinical trials with 2302 patients comprising 10 treatment arms did not suggest a significant change in plasma fibrinogen concentrations following metformin therapy (WMD: -0.25 g/L, 95% CI: -0.53, 0.04, p = 0.092). The effect size was robust in the leave-one-out sensitivity analysis and remained non-significant after omission of each single study from the meta-analysis. No significant effect of metformin on plasma fibrinogen concentrations was demonstrated in the current meta-analysis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Proteomics and the dynamic plasma membrane

    DEFF Research Database (Denmark)

    Sprenger, Richard R; Jensen, Ole Nørregaard

    2010-01-01

    plasma membrane is of particular interest, by not only serving as a barrier between the "cell interior" and the external environment, but moreover by organizing and clustering essential components to enable dynamic responses to internal and external stimuli. Defining and characterizing the dynamic plasma...... the challenges in functional proteomic studies of the plasma membrane. We review the recent progress in MS-based plasma membrane proteomics by presenting key examples from eukaryotic systems, including mammals, yeast and plants. We highlight the importance of enrichment and quantification technologies required...... for detailed functional and comparative analysis of the dynamic plasma membrane proteome....

  12. Analysis of ELM stability with extended MHD models in JET, JT-60U and future JT-60SA tokamak plasmas

    Science.gov (United States)

    Aiba, N.; Pamela, S.; Honda, M.; Urano, H.; Giroud, C.; Delabie, E.; Frassinetti, L.; Lupelli, I.; Hayashi, N.; Huijsmans, G.; JET Contributors, the; Research Unit, JT-60SA

    2018-01-01

    The stability with respect to a peeling-ballooning mode (PBM) was investigated numerically with extended MHD simulation codes in JET, JT-60U and future JT-60SA plasmas. The MINERVA-DI code was used to analyze the linear stability, including the effects of rotation and ion diamagnetic drift ({ω }* {{i}}), in JET-ILW and JT-60SA plasmas, and the JOREK code was used to simulate nonlinear dynamics with rotation, viscosity and resistivity in JT-60U plasmas. It was validated quantitatively that the ELM trigger condition in JET-ILW plasmas can be reasonably explained by taking into account both the rotation and {ω }* {{i}} effects in the numerical analysis. When deuterium poloidal rotation is evaluated based on neoclassical theory, an increase in the effective charge of plasma destabilizes the PBM because of an acceleration of rotation and a decrease in {ω }* {{i}}. The difference in the amount of ELM energy loss in JT-60U plasmas rotating in opposite directions was reproduced qualitatively with JOREK. By comparing the ELM affected areas with linear eigenfunctions, it was confirmed that the difference in the linear stability property, due not to the rotation direction but to the plasma density profile, is thought to be responsible for changing the ELM energy loss just after the ELM crash. A predictive study to determine the pedestal profiles in JT-60SA was performed by updating the EPED1 model to include the rotation and {ω }* {{i}} effects in the PBM stability analysis. It was shown that the plasma rotation predicted with the neoclassical toroidal viscosity degrades the pedestal performance by about 10% by destabilizing the PBM, but the pressure pedestal height will be high enough to achieve the target parameters required for the ITER-like shape inductive scenario in JT-60SA.

  13. Outcomes Related to the Use of Frozen Plasma or Pooled Solvent/Detergent-Treated Plasma in Critically Ill Children

    DEFF Research Database (Denmark)

    Camazine, Maraya N; Karam, Oliver; Colvin, Ryan

    2017-01-01

    OBJECTIVE: To determine if the use of fresh frozen plasma/frozen plasma 24 hours compared to solvent detergent plasma is associated with international normalized ratio reduction or ICU mortality in critically ill children. DESIGN: This is an a priori secondary analysis of a prospective, observati......OBJECTIVE: To determine if the use of fresh frozen plasma/frozen plasma 24 hours compared to solvent detergent plasma is associated with international normalized ratio reduction or ICU mortality in critically ill children. DESIGN: This is an a priori secondary analysis of a prospective....... SETTING: One hundred one PICUs in 21 countries. PATIENTS: All critically ill children admitted to a participating unit were included if they received at least one plasma unit during six predefined 1-week (Monday to Friday) periods. All children were exclusively transfused with either fresh frozen plasma...... was independently associated with reduced ICU mortality (odds ratio, 0.40; 95% CI, 0.16-0.99; p = 0.05). CONCLUSIONS: Solvent detergent plasma use in critically ill children may be associated with improved survival. This hypothesis-generating data support a randomized controlled trial comparing solvent detergent...

  14. PIXEL ANALYSIS OF PHOTOSPHERIC SPECTRAL DATA. I. PLASMA DYNAMICS

    Energy Technology Data Exchange (ETDEWEB)

    Rasca, Anthony P.; Chen, James [Plasma Physics Division, U.S. Naval Research Laboratory, Washington, DC 20375 (United States); Pevtsov, Alexei A., E-mail: anthony.rasca.ctr@nrl.navy.mil [National Solar Observatory, Sunspot, NM 88349 (United States)

    2016-11-20

    Recent observations of the photosphere using high spatial and temporal resolution show small dynamic features at or below the current resolving limits. A new pixel dynamics method has been developed to analyze spectral profiles and quantify changes in line displacement, width, asymmetry, and peakedness of photospheric absorption lines. The algorithm evaluates variations of line profile properties in each pixel and determines the statistics of such fluctuations averaged over all pixels in a given region. The method has been used to derive statistical characteristics of pixel fluctuations in observed quiet-Sun regions, an active region with no eruption, and an active region with an ongoing eruption. Using Stokes I images from the Vector Spectromagnetograph (VSM) of the Synoptic Optical Long-term Investigations of the Sun (SOLIS) telescope on 2012 March 13, variations in line width and peakedness of Fe i 6301.5 Å are shown to have a distinct spatial and temporal relationship with an M7.9 X-ray flare in NOAA 11429. This relationship is observed as stationary and contiguous patches of pixels adjacent to a sunspot exhibiting intense flattening in the line profile and line-center displacement as the X-ray flare approaches peak intensity, which is not present in area scans of the non-eruptive active region. The analysis of pixel dynamics allows one to extract quantitative information on differences in plasma dynamics on sub-pixel scales in these photospheric regions. The analysis can be extended to include the Stokes parameters and study signatures of vector components of magnetic fields and coupled plasma properties.

  15. Autocorrelation analysis of plasma plume light emissions in deep penetration laser welding of steel

    Czech Academy of Sciences Publication Activity Database

    Mrňa, Libor; Šarbort, Martin; Řeřucha, Šimon; Jedlička, Petr

    2017-01-01

    Roč. 29, č. 1 (2017), s. 1-10, č. článku 012009. ISSN 1042-346X R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : laser welding * plasma plume * light emissions * autocorrelation analysis * weld depth Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.492, year: 2016

  16. Comparative analysis of turbulent effects on thermal plasma characteristics inside the plasma torches with rod- and well-type cathodes

    International Nuclear Information System (INIS)

    Hur, Min; Hong, Sang Hee

    2002-01-01

    The thermal plasma characteristics inside the two non-transferred plasma torches with rod-type cathode (RTC) and well-type cathode (WTC) are analysed in conjunction with turbulent effects on them in the atmospheric-pressure conditions. A control volume method and a modified semi-implicit pressure linked equations revised algorithm are used for solving the governing equations, i.e. conservation equations of mass, momentum, and energy together with a current continuity equation for arc discharge. A cold flow analysis is introduced to find the cathode spot position in the WTC torch, and both the laminar and turbulent models are employed to gain a physical insight into the turbulent effects on the thermal plasma characteristics produced inside the two torches. The numerical analysis for an RTC torch shows that slightly different values of plasma temperature and velocity between the laminar and turbulent calculations occur and the radial temperature profiles are constricted at the axis with increasing the gas flow rate, and that the large turbulent viscosities appear mostly near the anode wall. These calculated results indicate that the turbulent effects on the thermal plasma characteristics are very weak in the whole discharge region inside the RTC torch. On the other hand, the calculated results of the two numerical simulations for a WTC torch present that the significantly different values of plasma characteristics between the two models appear in the whole torch region and the plasma temperatures decrease with increasing the gas flow rate because the relatively strong turbulent effects are prevailing in the entire interior region of the WTC torch. From the comparisons of plasma net powers calculated and measured in this work, the turbulent modelling turns out to provide the more accurately calculated results close to the measured ones compared with the laminar one, especially for the torch with WTC. This is because the turbulent effects are considerably strong in

  17. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    Science.gov (United States)

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.; Hartig, K. C.; Phillips, M. C.

    2018-06-01

    Rapid, in-field, and non-contact isotopic analysis of solid materials is extremely important to a large number of applications, such as nuclear nonproliferation monitoring and forensics, geochemistry, archaeology, and biochemistry. Presently, isotopic measurements for these and many other fields are performed in laboratory settings. Rapid, in-field, and non-contact isotopic analysis of solid material is possible with optical spectroscopy tools when combined with laser ablation. Laser ablation generates a transient vapor of any solid material when a powerful laser interacts with a sample of interest. Analysis of atoms, ions, and molecules in a laser-produced plasma using optical spectroscopy tools can provide isotopic information with the advantages of real-time analysis, standoff capability, and no sample preparation requirement. Both emission and absorption spectroscopy methods can be used for isotopic analysis of solid materials. However, applying optical spectroscopy to the measurement of isotope ratios from solid materials presents numerous challenges. Isotope shifts arise primarily due to variation in nuclear charge distribution caused by different numbers of neutrons, but the small proportional nuclear mass differences between nuclei of various isotopes lead to correspondingly small differences in optical transition wavelengths. Along with this, various line broadening mechanisms in laser-produced plasmas and instrumental broadening generated by the detection system are technical challenges frequently encountered with emission-based optical diagnostics. These challenges can be overcome by measuring the isotope shifts associated with the vibronic emission bands from molecules or by using the techniques of laser-based absorption/fluorescence spectroscopy to marginalize the effect of instrumental broadening. Absorption and fluorescence spectroscopy probe the ground state atoms existing in the plasma when it is cooler, which inherently provides narrower

  18. Identification of chronic heart failure patients with a high 12-month mortality risk using biomarkers including plasma C-terminal pro-endothelin-1.

    Directory of Open Access Journals (Sweden)

    Ewa A Jankowska

    Full Text Available OBJECTIVES: We hypothesised that assessment of plasma C-terminal pro-endothelin-1 (CT-proET-1, a stable endothelin-1 precursor fragment, is of prognostic value in patients with chronic heart failure (CHF, beyond other prognosticators, including N-terminal pro-B-type natriuretic peptide (NT-proBNP. METHODS: We examined 491 patients with systolic CHF (age: 63±11 years, 91% men, New York Heart Association [NYHA] class [I/II/III/IV]: 9%/45%/38%/8%, 69% ischemic etiology. Plasma CT-proET-1 was detected using a chemiluminescence immunoassay. RESULTS: Increasing CT-proET-1 was a predictor of increased cardiovascular mortality at 12-months of follow-up (standardized hazard ratio 1.42, 95% confidence interval [CI] 1.04-1.95, p = 0.03 after adjusting for NT-proBNP, left ventricular ejection fraction (LVEF, age, creatinine, NYHA class. In receiver operating characteristic curve analysis, areas under curve for 12-month follow-up were similar for CT-proET-1 and NT-proBNP (p = 0.40. Both NT-proBNP and CT-proET-1 added prognostic value to a base model that included LVEF, age, creatinine, and NYHA class. Adding CT-proET-1 to the base model had stronger prognostic power (p<0.01 than adding NT-proBNP (p<0.01. Adding CT-proET-1 to NT-proBNP in this model yielded further prognostic information (p = 0.02. CONCLUSIONS: Plasma CT-proET-1 constitutes a novel predictor of increased 12-month cardiovascular mortality in patients with CHF. High CT-proET-1 together with high NT-proBNP enable to identify patients with CHF and particularly unfavourable outcomes.

  19. Spectral analysis of K-shell X-ray emission of magnesium plasma

    Indian Academy of Sciences (India)

    2014-02-06

    Feb 6, 2014 ... Spectral analysis of K-shell X-ray emission of magnesium plasma, produced by laser pulses of 45 fs duration, focussed up to an intensity of ∼1018 W cm-2, is carried out. The plasma conditions prevalent during the emission of X-ray spectrum were identified by comparing the experimental spectra with the ...

  20. Analysis of 6-mercaptopurine in human plasma with a high-performance liquid chromatographic method including post-column derivatization and fluorimetric detection.

    Science.gov (United States)

    Jonkers, R E; Oosterhuis, B; ten Berge, R J; van Boxtel, C J

    1982-12-10

    A relatively simple assay with improved reliability and sensitivity for measuring levels of 6-mercaptopurine in human plasma is presented. After extraction of the compound and the added internal standard with phenyl mercury acetate, samples were separated by ion-pair reversed-phase high-performance liquid chromatography. On-line the analytes were oxidized to fluorescent products and detected in a flow-fluorimeter. The within-day coefficient of variation was 3.8% at a concentration of 25 ng/ml. The lower detection limit was 2 ng/ml when 1.0 ml of plasma was used. Mercaptopurine concentration versus time curves of two subjects after a single oral dose of azathioprine are shown.

  1. Plasma Exchange for Renal Vasculitis and Idiopathic Rapidly Progressive Glomerulonephritis: A Meta-analysis

    DEFF Research Database (Denmark)

    Walsh, Michael; Catapano, Fausta; Szpirt, Wladimir

    2010-01-01

    exchange did not differ significantly across the range of baseline serum creatinine values (P = 0.7) or number of plasma exchange treatments (P = 0.8). The RR for end-stage renal disease was 0.64 (95% CI, 0.47-0.88; P = 0.006), whereas the RR for death alone was 1.01 (95% CI, 0.71-1.4; P = 0......BACKGROUND:: Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis. STUDY DESIGN:: Systematic review and meta-analysis of articles identified from...

  2. HPLC analysis of prostaglandin metabolites plasma from irradiated rats

    International Nuclear Information System (INIS)

    Walden, T.L. Jr.; Catravas, G.N.

    1985-01-01

    The authors used RP-HPLC to quantitatively and qualitatively evaluate the PG metabolites in the plasma of rats during the first 24 hrs following a 10 Gy whole body dose of cobalt 60 gamma rays. The PGs and other arachidonic acid metabolites in plasma were extracted and then covalently attached to a fluroescent dye to enhance detection. A number of PGs and their metabolites were observed in the irradiated sample, including: 13,14 dihydro -15 keto PGE/sub 2/ and 13,14, dihydro -15 keto PGF/sub 2/, and their respective precursors, PGE/sub 2/ and PGF/sub 2/. The two major compounds present in the plasma samples were 13,14 dihydro -15 keto PFG/sub 2/ and another compound which is as yet unidentified. The levels of the individual PGs within a sample varied with time after irradiation, and the time at which a PG reached a peak level in the plasma depended on the particular PG in question. 13,14 dihdyro -15 keto PGD/sub 2/ was observed to reach a peak plasma concentration at 6 hours postirradiation, and at that time was at least 20 times higher than control levels

  3. Plasma diagnostics surface analysis and interactions

    CERN Document Server

    Auciello, Orlando

    2013-01-01

    Plasmas and their interaction with materials have become subjects of major interest because of their importance in modern forefront technologies such as microelectronics, fusion energy, and space. Plasmas are used in microelectronics to process semiconductors (etching of patterns for microcircuits, plasma-induced deposition of thin films, etc.); plasmas produce deleterious erosion effects on surfaces of materials used for fusion devices and spaceships exposed to the low earth environment.Diagnostics of plasmas and materials exposed to them are fundamental to the understanding of the physical a

  4. Analysis of core plasma heating and ignition by relativistic electrons

    International Nuclear Information System (INIS)

    Nakao, Y.

    2002-01-01

    Clarification of the pre-compressed plasma heating by fast electrons produced by relativistic laser-plasma interaction is one of the most important issues of the fast ignition scheme in ICF. On the basis of overall calculations including the heating process, both by relativistic hot electrons and alpha-particles, and the hydrodynamic evolution of bulk plasma, we examine the feature of core plasma heating and the possibility of ignition. The deposition of the electron energy via long-range collective mode, i.e. Langmuir wave excitation, is shown to be comparable to that through binary electron-electron collisions; the calculation neglecting the wave excitation considerably underestimates the core plasma heating. The ignition condition is also shown in terms of the intensity I(h) and temperature T(h) of hot electrons. It is found that I(h) required for ignition increases in proportion to T(h). For efficiently achieving the fast ignition, electron beams with relatively 'low' energy (e.g.T(h) below 1 MeV) are desirable. (author)

  5. Bifurcation of space-charge wave in a plasma waveguide including the wake potential effect

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung-Jae [Department of Physics and Research Institute for Natural Sciences, Hanyang University, Seoul 04763 (Korea, Republic of); Jung, Young-Dae, E-mail: ydjung@hanyang.ac.kr [Department of Applied Physics and Department of Bionanotechnology, Hanyang University, Ansan, Kyunggi-Do 15588, South Korea and Department of Physics, Applied Physics, and Astronomy, Rensselaer Polytechnic Institute, 110 8th Street, Troy, New York 12180-3590 (United States)

    2016-09-15

    The wake potential effects on the propagation of the space-charge dust ion-acoustic wave are investigated in a cylindrically bounded dusty plasma with the ion flow. The results show that the wake potential would generate the double frequency modes in a cylindrically bounded dusty plasma. It is found that the upper mode of the wave frequency with the root of higher-order is smaller than that with the root of lower-order in intermediate wave number domains. However, the lower mode of the scaled wave frequency with the root of higher-order is found to be greater than that with the root of lower-order. It is found that the influence in the order of the root of the Bessel function on the wave frequency of the space-charge dust-ion-acoustic wave in a cylindrically confined dusty plasma decreases with an increase in the propagation wave number. It is also found that the double frequency modes increase with increasing Mach number due to the ion flow in a cylindrical dusty plasma. In addition, it is found that the upper mode of the group velocity decreases with an increase in the scaled radius of the plasma cylinder. However, it is shown that the lower mode of the scaled group velocity of the space-charge dust ion acoustic wave increases with an increase in the radius of the plasma cylinder. The variation of the space-charge dust-ion-acoustic wave due to the wake potential and geometric effects is also discussed.

  6. Thermal analysis of the in-vessel components of the ITER plasma-position reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Quental, P. B., E-mail: pquental@ipfn.tecnico.ulisboa.pt; Policarpo, H.; Luís, R.; Varela, P. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa (Portugal)

    2016-11-15

    The ITER plasma position reflectometry system measures the edge electron density profile of the plasma, providing real-time supplementary contribution to the magnetic measurements of the plasma-wall distance. Some of the system components will be in direct sight of the plasma and therefore subject to plasma and stray radiation, which may cause excessive temperatures and stresses. In this work, thermal finite element analysis of the antenna and adjacent waveguides is conducted with ANSYS V17 (ANSYS® Academic Research, Release 17.0, 2016). Results allow the identification of critical temperature points, and solutions are proposed to improve the thermal behavior of the system.

  7. Plasma urate concentration and risk of coronary heart disease: a Mendelian randomisation analysis

    Science.gov (United States)

    White, Jon; Sofat, Reecha; Hemani, Gibran; Shah, Tina; Engmann, Jorgen; Dale, Caroline; Shah, Sonia; Kruger, Felix A; Giambartolomei, Claudia; Swerdlow, Daniel I; Palmer, Tom; McLachlan, Stela; Langenberg, Claudia; Zabaneh, Delilah; Lovering, Ruth; Cavadino, Alana; Jefferis, Barbara; Finan, Chris; Wong, Andrew; Amuzu, Antoinette; Ong, Ken; Gaunt, Tom R; Warren, Helen; Davies, Teri-Louise; Drenos, Fotios; Cooper, Jackie; Ebrahim, Shah; Lawlor, Debbie A; Talmud, Philippa J; Humphries, Steve E; Power, Christine; Hypponen, Elina; Richards, Marcus; Hardy, Rebecca; Kuh, Diana; Wareham, Nicholas; Ben-Shlomo, Yoav; Day, Ian N; Whincup, Peter; Morris, Richard; Strachan, Mark W J; Price, Jacqueline; Kumari, Meena; Kivimaki, Mika; Plagnol, Vincent; Whittaker, John C; Smith, George Davey; Dudbridge, Frank; Casas, Juan P; Holmes, Michael V; Hingorani, Aroon D

    2016-01-01

    Summary Background Increased circulating plasma urate concentration is associated with an increased risk of coronary heart disease, but the extent of any causative effect of urate on risk of coronary heart disease is still unclear. In this study, we aimed to clarify any causal role of urate on coronary heart disease risk using Mendelian randomisation analysis. Methods We first did a fixed-effects meta-analysis of the observational association of plasma urate and risk of coronary heart disease. We then used a conventional Mendelian randomisation approach to investigate the causal relevance using a genetic instrument based on 31 urate-associated single nucleotide polymorphisms (SNPs). To account for potential pleiotropic associations of certain SNPs with risk factors other than urate, we additionally did both a multivariable Mendelian randomisation analysis, in which the genetic associations of SNPs with systolic and diastolic blood pressure, HDL cholesterol, and triglycerides were included as covariates, and an Egger Mendelian randomisation (MR-Egger) analysis to estimate a causal effect accounting for unmeasured pleiotropy. Findings In the meta-analysis of 17 prospective observational studies (166 486 individuals; 9784 coronary heart disease events) a 1 SD higher urate concentration was associated with an odds ratio (OR) for coronary heart disease of 1·07 (95% CI 1·04–1·10). The corresponding OR estimates from the conventional, multivariable adjusted, and Egger Mendelian randomisation analysis (58 studies; 198 598 individuals; 65 877 events) were 1·18 (95% CI 1·08–1·29), 1·10 (1·00–1·22), and 1·05 (0·92–1·20), respectively, per 1 SD increment in plasma urate. Interpretation Conventional and multivariate Mendelian randomisation analysis implicates a causal role for urate in the development of coronary heart disease, but these estimates might be inflated by hidden pleiotropy. Egger Mendelian randomisation analysis, which accounts for

  8. Effect of garlic on plasma lipoprotein(a) concentrations: A systematic review and meta-analysis of randomized controlled clinical trials.

    Science.gov (United States)

    Sahebkar, Amirhossein; Serban, Corina; Ursoniu, Sorin; Banach, Maciej

    2016-01-01

    Garlic can play an essential role in the prevention of atherosclerosis, but the research addressing the effect of garlic on the concentration of lipoprotein(a) [Lp(a)] has not been fully demonstrated. The aim of this study was to assess the effect of garlic on plasma Lp(a) concentrations through systematic review of literature and meta-analysis of available randomized controlled trials. The literature search included SCOPUS, PubMed-Medline, ISI Web of Science, and Google Scholar databases up to March 10, 2015 to identify randomized controlled trials investigating the effect of garlic on plasma Lp(a) concentrations. Two independent reviewers extracted data on study characteristics, methods, and outcomes. Overall, the effect of garlic on plasma Lp(a) levels was reported in six trials. Meta-analysis did not suggest a significant alteration in plasma Lp(a) levels after garlic consumption (weighted mean difference [WMD] = 16.86%; 95% confidence interval, -4.59 to 38.31; P = 0.124). This result was robust in the leave-one-out sensitivity analysis. When the studies were categorized according to the duration of supplementation, there was no effect in the subgroup of trials lasting ≤12 wk (WMD = 2.01%; 95% CI, -14.67 to 18.68; P = 0.813) but a significant elevation of plasma Lp(a) concentrations was found in trials lasting >12 wk (WMD = 54.59%; 95% CI, 30.47-78.71; P meta-regression suggested an inverse association between the changes in plasma concentrations of Lp(a) and duration of supplementation (slope 1.71; 95% CI, 0.46-2.97; P = 0.007). The present meta-analysis did not suggest a significant effect of garlic supplementation on the reduction of Lp(a) levels. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Analysis of plasma coupling with the prototype DIII-D ICRF antenna

    International Nuclear Information System (INIS)

    Ryan, P.M.; Hoffman, D.J.; Bigelow, T.S.; Baity, F.W.; Gardner, W.L.; Mayberry, M.J.; Rothe, K.E.

    1988-01-01

    Coupling to plasma in the H-mode is essential to the success of future ignited machines such as CIT. To ascertain voltage and current requirements for high-power second harmonic heating (2 MW in a 35- by 50-cm port), coupling to the DIII-D tokamak with a prototype compact loop antenna has been measured. The results show good loading for L-mode and limiter plasmas, but coupling 2 MW to an H-mode plasma demands voltages and currents near the limit of present technology. We report the technological analysis and progress that allow coupling of these power densities. 5 refs., 4 figs

  10. Analysis of plasma coupling with the prototype DIII-D ICRF antenna

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, P.M.; Hoffman, D.J.; Bigelow, T.S.; Baity, F.W.; Gardner, W.L.; Mayberry, M.J.; Rothe, K.E.

    1988-01-01

    Coupling to plasma in the H-mode is essential to the success of future ignited machines such as CIT. To ascertain voltage and current requirements for high-power second harmonic heating (2 MW in a 35- by 50-cm port), coupling to the DIII-D tokamak with a prototype compact loop antenna has been measured. The results show good loading for L-mode and limiter plasmas, but coupling 2 MW to an H-mode plasma demands voltages and currents near the limit of present technology. We report the technological analysis and progress that allow coupling of these power densities. 5 refs., 4 figs.

  11. Analysis of the plasma impurity influx from alkali-metal coatings for fusion-reactor applications

    International Nuclear Information System (INIS)

    DeWald, A.B.; Davidson, J.N.; Krauss, A.R.; Gruen, D.M.

    1982-01-01

    Recently, it has been proposed that alkali-metal covered surfaces be applied to magnetic fusion devices as a means of controlling plasma impurity contamination and shielding the substrate from erosion. Monolayer films of alkali metals have been shown to sputter primarily as ions under particle bombardment. Thus, it is thought that a sheath potential and/or magnetic fields encountered by a sputtered ion will return the ion to the surface without entering the plasma. In this paper, we investigate the net wall impurity influx associated with coatings which exhibit substantial secondary ion emission as compared to those which sputter only as neutral atoms. Included in the analysis are sputtered substrate atoms. These are sometimes found to be a significant fraction of the total sputtering yield for low-Z alkali monolayers and affect the overall performance of such coatings. Estimates of the impurity influx made in the neighborhood of a sheath potential show that secondary-ion emitting coatings are effective as a means of inhibiting plasma impurity contamination and wall erosion

  12. Analysis of radiofrequency discharges in plasma

    Science.gov (United States)

    Kumar, D.; McGlynn, S.P.

    1992-08-04

    Separation of laser optogalvanic signals in plasma into two components: (1) an ionization rate change component, and (2) a photoacoustic mediated component. This separation of components may be performed even when the two components overlap in time, by measuring time-resolved laser optogalvanic signals in an rf discharge plasma as the rf frequency is varied near the electrical resonance peak of the plasma and associated driving/detecting circuits. A novel spectrometer may be constructed to make these measurements. Such a spectrometer would be useful in better understanding and controlling such processes as plasma etching and plasma deposition. 15 figs.

  13. Chemical analysis of plasma-assisted antimicrobial treatment on cotton

    International Nuclear Information System (INIS)

    Kan, C W; Lam, Y L; Yuen, C W M; Luximon, A; Lau, K W; Chen, K S

    2013-01-01

    This paper explores the use of plasma treatment as a pretreatment process to assist the application of antimicrobial process on cotton fabric with good functional effect. In this paper, antimicrobial finishing agent, Microfresh Liquid Formulation 9200-200 (MF), and a binder (polyurethane dispersion, Microban Liquid Formulation R10800-0, MB) will be used for treating the cotton fabric for improving the antimicrobial property and pre-treatment of cotton fabric by plasma under atmospheric pressure will be employed to improve loading of chemical agents. The chemical analysis of the treated cotton fabric will be conducted by Fourier transform Infrared Spectroscopy.

  14. Erosion/redeposition analysis : status of modeling and code validation for semi-detached tokamak edge plasmas

    International Nuclear Information System (INIS)

    Brooks, J. N.

    1999-01-01

    We are analyzing erosion and tritium codeposition for ITER, DIII-D, and other devices with a focus on carbon divertor and metallic wall sputtering, for detached and semi-detached edge plasmas. Carbon chemical-sputtering hydrocarbon-transport is computed in detail using upgraded models for sputtering yields, species, and atomic and molecular processes. For the DIII-D analysis this includes proton impact and dissociative recombination for the full methane and higher hydrocarbon chains. Several mixed material (Si-C doping and Be/C) effects on erosion are examined. A semi-detached reactor plasma regime yields peak net wall erosion rates of ∼1.0 (Be), ∼0.3 (Fe), and ∼0.01 (W) cm/burn-yr, and ∼50 cm/burn-yr for a carbon divertor. Net carbon erosion is dominated by chemical sputtering in the ∼1-3 eV detached plasma zone. Tritium codeposition in divertor-sputtered redeposited carbon is high (∼10-20 g-T/1000 s ). Silicon and beryllium mixing tends to reduce carbon erosion. Initial hydrocarbon transport calculations for the DIII-D DiMES-73 detached plasma experiment show a broad spectrum of redeposited molecules with ∼90% redeposition fraction

  15. Collisional boundary layer analysis for neoclassical toroidal plasma viscosity in tokamaks

    International Nuclear Information System (INIS)

    Shaing, K. C.; Cahyna, P.; Becoulet, M.; Park, J.-K.; Sabbagh, S. A.; Chu, M. S.

    2008-01-01

    It is demonstrated that the pitch angle integrals in the transport fluxes in the ν regime calculated in K. C. Shang [Phys. Plasmas 10, 1443 (2003)] are divergent as the trapped-circulating boundary is approached. Here, ν is the collision frequency. The origin of this divergence results from the logarithmic dependence in the bounce averaged radial drift velocity. A collisional boundary layer analysis is developed to remove the singularity. The resultant pitch angle integrals now include not only the original physics of the ν regime but also the boundary layer physics. The transport fluxes, caused by the particles inside the boundary layer, scale as √(ν)

  16. Dynamic plasma screening effects on atomic collisions in dense plasmas

    International Nuclear Information System (INIS)

    Young-Dae Jung

    1999-01-01

    Dynamic plasma screening effects are investigated on electron-ion collisional excitation and Coulomb Bremsstrahlung processes in dense plasmas. The electron-ion interaction potential is considered by introduction of the plasma dielectric function. The straight-ling trajectory method is applied to the path of the projectile electron. The transition probability including the dynamic plasma screening effect is found to be always greater than that including the static plasma screening effects. It is found that the differential Bremsstrahlung radiation cross section including the dynamic plasma screening effect is also greater than that including the static plasma screening effect. When the projectile velocity is smaller than the electron thermal velocity, the dynamic polarization screening effect becomes the static plasma screening effect. However, when the projectile velocity is greater than the electron thermal velocity, the interaction potential is almost unshielded

  17. Plasma heating

    International Nuclear Information System (INIS)

    Wilhelm, R.

    1989-01-01

    Successful plasma heating is essential in present fusion experiments, for the demonstration of DpT burn in future devices and finally for the fusion reactor itself. This paper discusses the common heating systems with respect to their present performance and their applicability to future fusion devices. The comparative discussion is oriented to the various function of heating, which are: - plasma heating to fusion-relevant parameters and to ignition in future machines, -non-inductive, steady-pstate current drive, - plasma profile control, -neutral gas breakdown and plasma build-up. In view of these different functions, the potential of neutral beam injection (NBI) and the various schemes of wave heating (ECRH, LH, ICRH and Alven wave heating) is analyzed in more detail. The analysis includes assessments of the present physical and technical state of these heating methods, and makes suggestions for future developments and about outstanding problems. Specific attention is given to the still critical problem of efficient current drive, especially with respect to further extrapolation towards an economically operating tokamak reactor. Remarks on issues such as reliability, maintenance and economy conclude this comparative overview on plasma heating systems. (author). 43 refs.; 13 figs.; 3 tabs

  18. Energy principle with included boundary conditions

    International Nuclear Information System (INIS)

    Lehnert, B.

    1994-01-01

    Earlier comments by the author on the limitations of the classical form of the extended energy principle are supported by a complementary analysis on the potential energy change arising from free-boundary displacements of a magnetically confined plasma. In the final formulation of the extended principle, restricted displacements, satisfying pressure continuity by means of plasma volume currents in a thin boundary layer, are replaced by unrestricted (arbitrary) displacements which can give rise to induced surface currents. It is found that these currents contribute to the change in potential energy, and that their contribution is not taken into account by such a formulation. A general expression is further given for surface currents induced by arbitrary displacements. The expression is used to reformulate the energy principle for the class of displacements which satisfy all necessary boundary conditions, including that of the pressure balance. This makes a minimization procedure of the potential energy possible, for the class of all physically relevant test functions which include the constraints imposed by the boundary conditions. Such a procedure is also consistent with a corresponding variational calculus. (Author)

  19. Combline antenna modeling for plasma heating

    International Nuclear Information System (INIS)

    Nelson, S.D.; Kamin, G.; Van Maren, R.; Poole, B.; Moeller, C.; Phelps, D.

    1996-01-01

    The combline antenna for plasma heating, as proposed by General Atomics(1), has unique potential for solving many plasma drive problems. The benefit of the combline design is the utilization of the coupling between elements that avoids a more cumbersome multidrive system. This design is being investigated using computational EM modeling codes in the 100 endash 400 MHz band using resources at General Atomics and LLNL. Preliminary experimental results, using a combline mockup, agree well with 3D modeling efforts including resonant frequency alignment and amplitudes. These efforts have been expanded into an endeavor to optimize the combline design using both time and frequency domain codes. This analysis will include plasma coupling but to date has been limited to antenna effects. The combline antenna system is modeled in 3D using a combination of computational tools in the time domain, for temporal feature isolation purposes, and in the frequency domain, for resonant structure analysis. Both time and frequency domain modeling details include the Faraday shield elements, the strap elements, and the feed structure. copyright 1996 American Institute of Physics

  20. Plasma ET-1 Concentrations Are Elevated in Pregnant Women with Hypertension -Meta-Analysis of Clinical Studies

    Directory of Open Access Journals (Sweden)

    Yong-Ping Lu

    2017-11-01

    Full Text Available Background/Aims: The ET system might be involved in the pathogenesis of hypertensive disorders during pregnancy. The objective is to analyse the impact of ET-1 in hypertensive pregnant women by a strict meta-analysis of published human clinical studies. Methods: Based on the principle of Cochrane systematic reviews, Cohort studies in PubMed (Medline, Google Scholar and China Biological Medicine Database (CBM-disc designed to identify the role of endothelin-1 (ET-1 in the pathophysiology of gestational hypertension and preeclampsia were screened. Review Manager Version 5.0 (Rev-Man 5.0 was applied for statistical analysis. Mean difference and 95% confidence interval (CI were shown in inverse variance (IV fixed-effects model or IV random-effects model. Results: Sixteen published cohort studies including 1739 hypertensive cases and 409 controls were used in the meta-analysis. ET-1 plasma concentrations were higher in hypertensive pregnant women as compared to the controls (mean difference between groups: 19.02 [15.60~22.44], P < 0.00001,. These finding were driven by severity of hypertension and/or degree of proteinuria. Conclusion: Plasma ET-1 concentrations are elevated in hypertensive disorders during human pregnancy. In particular women with preeclampsia (hypertensive pregnant women with proteinuria have substantially elevated plasma ET-1 concentration as compared to pregnant women with normal blood pressure.

  1. First comparative analysis concerning the plasma platelet contamination during MNC collection.

    Science.gov (United States)

    Pfeiffer, Hella; Achenbach, Susanne; Strobel, Julian; Zimmermann, Robert; Eckstein, Reinhold; Strasser, Erwin F

    2017-08-01

    Monocytes can be cultured into dendritic cells with addition of autologous plasma, which is highly prone to platelet contamination due to the apheresis process. Since platelets affect the maturation process of monocytes into dendritic cells and might even lead to a diminished harvest of dendritic cells, it is very important to reduce the platelet contamination. A new collection device (Spectra Optia) was analyzed, compared to two established devices (COM.TEC, Cobe Spectra) and evaluated regarding the potential generation of source plasma. Concurrent plasma collected during leukapheresis was analyzed for residual cell contamination in a prospective study with the new Spectra Optia apheresis device (n=24) and was compared with COM.TEC and Cobe Spectra data (retrospective analysis, n=72). Donor pre-donation counts of platelets were analyzed for their predictive value of contaminating PLTs in plasma harvests. The newest apheresis device showed the lowest residual platelet count of the collected concurrent plasma (median 3.50×10 9 /l) independent of pre-donation counts. The other two devices and sets had a higher platelet contamination. The contamination of the plasma with leukocytes was very low (only 2.0% were higher than 0.5×10 9 /l). This study showed a significant reduction of platelet contamination of the concurrent plasma collected with the new Spectra Optia device. This plasma product with low residual platelets and leukocytes might also be used as plasma for fractionation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Evolution of α-particle distribution in burning plasmas including energy dependent α-transport effects

    International Nuclear Information System (INIS)

    Kamelander, G.; Sigmar, D.; Woloch, F.

    1991-09-01

    This report resumes the essential results of a common OEFZS/MIT (Plasma Fusion Center) project to investigate fusion alpha transport. A computer code has been developed going beyond standard FOKKER-PLANCK-codes assuming that the fusion products give their energy to the plasma on the place of their birth. The present transport code admits the calculation of the α-distribution function. By means of the distribution function the energy deposition rates are calculated. The time-evolution of the α-distribution function has been evaluated for an ignited plasma. A description of the transport code, of the subroutines and of the input data as well as a listing is enclosed to this report. (Authors)

  3. Spectrochemical analysis of plutonium using direct current plasma emission spectrometry

    International Nuclear Information System (INIS)

    Morris, W.F.; Fadeff, S.K.; Torres, S.

    1983-01-01

    One year ago, LLNL was just completing the installation of a Direct Current Plasma (DCP) spectrometer for the analysis of Pu and Pu alloys. The installation was completed in December 1982 and has been utilized regularly for Pu analysis since then. This paper discusses the experience with the instrument and some data demonstrating its performance

  4. Three-dimensional analysis of nonlinear plasma oscillation

    International Nuclear Information System (INIS)

    Miano, G.

    1990-01-01

    In an underdense plasma a large-amplitude plasma oscillation may be produced by the beating of two external and colinear electromagnetic waves with a frequency difference approximately equal to the plasma frequency - plasma beat wave (PBW) resonant mechanism. The plasma oscillations are driven by the ponderomotive force arising from the beating of the two imposed electromagnetic waves. In this paper two pump electromagnetic waves with arbitrary transverse profiles have been considered. The plasma is described by using the three dimensinal weakly relativistic fluid equations. The nonlinear plasma oscillation dynamics is studied by using the eulerian description, the averaging and the multiple time scale methods. Unlike the linear theory a strong cross field coupling between longitudinal ans transverse electric field components of the plasma oscillation comes out, resulting in a nonlinear phase change and energy transfer between the two components. Unlike the one-dimensional nonlinear theory, the nonlinear frequency shift is caused by relativistic effects as well as by convective effects and electromagnetic field generated from the three dimensional plasma oscillation. The large amplitude plasma oscillation dynamics produced by a bunched relativistic electron beam with arbitrary transverse profile - plasma wave field (PWF) - or by a high power single frequency short electromagnetic pulse with arbitrary transverse profile - electromagnetic plasma wake field (EPWF) - may be described by means of the present theory. (orig.)

  5. Numerical analysis on the ion species ratios in a steady state hydrogen plasma

    International Nuclear Information System (INIS)

    Fukumasa, Osamu; Saeki, Setsuo; Osaki, Katashi; Sakiyama, Satoshi; Itatani, Ryohei.

    1984-07-01

    Ion species ratios in a hydrogen plasma are calculated systematically as a function of plasma parameters, i.e. the electron density, the electron temperature, the pressure of hydrogen gas and the plasma volume. Furthermore, in the present analysis, the recombination factor for hydrogen atoms at the wall surface of a vacuum vessel is treated as another plasma parameter. The most significant point is that ion species ratios depend strongly not only on plasma parameters, but also on the recombination factor. The proton ratio increases with decreasing value of the recombination factor. Primary electrons also play an important role for ion species ratios, and the presence of primary electrons causes the proton ratio to decrease. (author)

  6. Analysis of 26-hydroxycholesterol in plasma by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Kou, I.L.; Holmes, R.P.

    1986-01-01

    A method utilizing HPLC has been developed for the analysis of 26-hydroxycholesterol in plasma. The method involves initially saponifying samples for estimation of the total sterol or extracting samples with acetonitrile to estimate the free sterol. This is followed by a C-18 Sep Pak fractionation of the extracts, further purification on a Nova Pak C-18 HPLC column, and finally by quantitation on a silicic acid HPLC column by measuring the absorbance at 210 nm. Losses of sterol during this multi-step procedure were determined by estimating the recovery of 3 H-26-hydroxycholesterol added to samples before extraction or saponification. The reproducibility of the method was evaluated by repetitive analysis of one plasma sample. The coefficient of variation was 6.8% for six analyses. In agreement with the mass spectrometric determinations of Javitt et al. The authors observed total plasma levels in the range of 140-260 ng/ml in young adult humans, rats, and rabbits. In the plasma of older human patients undergoing coronary by-pass surgery levels ranged from 335-950 ng/ml, suggesting that an increase in the level of 26-hydroxycholesterol is either age-related or related to the development of acute atherosclerosis

  7. Minimally-invasive Laser Ablation Inductively Coupled Plasma Mass Spectrometry analysis of model ancient copper alloys

    Energy Technology Data Exchange (ETDEWEB)

    Walaszek, Damian [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre, Żwirki i Wigury 101, 02-089 Warszawa (Poland); Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Senn, Marianne; Wichser, Adrian [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Faller, Markus [Laboratory for Jointing Technology and Corrosion, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Wagner, Barbara; Bulska, Ewa [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre, Żwirki i Wigury 101, 02-089 Warszawa (Poland); Ulrich, Andrea [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland)

    2014-09-01

    This work describes an evaluation of a strategy for multi-elemental analysis of typical ancient bronzes (copper, lead bronze and tin bronze) by means of laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS).The samples originating from archeological experiments on ancient metal smelting processes using direct reduction in a ‘bloomery’ furnace as well as historical casting techniques were investigated with the use of the previously proposed analytical procedure, including metallurgical observation and preliminary visual estimation of the homogeneity of the samples. The results of LA-ICPMS analysis were compared to the results of bulk composition obtained by X-ray fluorescence spectrometry (XRF) and by inductively coupled plasma mass spectrometry (ICPMS) after acid digestion. These results were coherent for most of the elements confirming the usefulness of the proposed analytical procedure, however the reliability of the quantitative information about the content of the most heterogeneously distributed elements was also discussed in more detail. - Highlights: • The previously proposed procedure was evaluated by analysis of model copper alloys. • The LA-ICPMS results were comparable to the obtained by means of XRF and ICPMS. • LA-ICPMS results indicated the usefulness of the proposed analytical procedure.

  8. Automated detection and analysis of particle beams in laser-plasma accelerator simulations

    International Nuclear Information System (INIS)

    Ushizima, Daniela Mayumi; Geddes, C.G.; Cormier-Michel, E.; Bethel, E. Wes; Jacobsen, J.; Prabhat; Ruebel, O.; Weber, G.; Hamann, B.

    2010-01-01

    Numerical simulations of laser-plasma wakefield (particle) accelerators model the acceleration of electrons trapped in plasma oscillations (wakes) left behind when an intense laser pulse propagates through the plasma. The goal of these simulations is to better understand the process involved in plasma wake generation and how electrons are trapped and accelerated by the wake. Understanding of such accelerators, and their development, offer high accelerating gradients, potentially reducing size and cost of new accelerators. One operating regime of interest is where a trapped subset of electrons loads the wake and forms an isolated group of accelerated particles with low spread in momentum and position, desirable characteristics for many applications. The electrons trapped in the wake may be accelerated to high energies, the plasma gradient in the wake reaching up to a gigaelectronvolt per centimeter. High-energy electron accelerators power intense X-ray radiation to terahertz sources, and are used in many applications including medical radiotherapy and imaging. To extract information from the simulation about the quality of the beam, a typical approach is to examine plots of the entire dataset, visually determining the adequate parameters necessary to select a subset of particles, which is then further analyzed. This procedure requires laborious examination of massive data sets over many time steps using several plots, a routine that is unfeasible for large data collections. Demand for automated analysis is growing along with the volume and size of simulations. Current 2D LWFA simulation datasets are typically between 1GB and 100GB in size, but simulations in 3D are of the order of TBs. The increase in the number of datasets and dataset sizes leads to a need for automatic routines to recognize particle patterns as particle bunches (beam of electrons) for subsequent analysis. Because of the growth in dataset size, the application of machine learning techniques for

  9. Analysis of detached recombining plasmas by collisonal-radiative model with energetic electron component

    International Nuclear Information System (INIS)

    Ohno, N.; Motoyama, M.; Takamura, S.

    2001-01-01

    Investigation of plasma detachment is still one of the most important subjects in the edge plasma of magnetically confined fusion devices. It was found that volumetric plasma recombination plays an essential role on reduction of particle flux in detached plasmas. The volumetric plasma recombination process has been confirmed in several diverted tokamaks and linear simulators by observing line emission from highly excited states due to three-body recombination process and continuum emission due to radiative recombination process. Electron temperature and density in the detached plasma were also evaluated from analysis of the light emission. To determine the electron temperature, the line emission spectrum is analyzed to calculate the population densities of excited levels. The population distribution among the highly excited states follows the Saha-Boltzmann distribution very closely. This implies that those states are in local thermal equilibrium (LTE) condition with free electrons in plasma so that the electron temperature can be obtained by using method of Boltzmann plot. Another method to determine the electron temperature is to compare the observed continuum spectrum with the theoretically calculated one. In our experiments using the linear diverter simulator, however, there is a clear difference for two evaluated values. One of the possible reasons is thought to be that there is a small amount of energetic electrons existing in detached recombining region. In order to evaluate the electron temperature more preciously, we need to investigate the influence of the energetic electrons on the evaluation of bulk electron temperature in a detached plasma. Collisonal-radiative (GR) model has been utilized for analyzing the light emission intensities from plasma. However, Maxwellian electron distribution function is usually assumed in the CR model. In this paper, we report a quantitative analysis of the line emission spectrum in the detached recombining plasmas by

  10. Plasma Heating in Solar Microflares: Statistics and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kirichenko, A. S.; Bogachev, S. A. [Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, 119991 (Russian Federation)

    2017-05-01

    In this paper we present the results of an analysis of 481 weak solar flares, from A0.01 class flares to the B GOES class, that were observed during the period of extremely low solar activity from 2009 April to July. For all flares we measured the temperature of the plasma in the isothermal and two-temperature approximations and tried to fit its relationship with the X-ray class using exponential and power-law functions. We found that the whole temperature distribution in the range from A0.01 to X-class cannot be fit by one exponential function. The fitting for weak flares below A1.0 is significantly steeper than that for medium and large flares. The power-law approximation seems to be more reliable: the corresponding functions were found to be in good agreement with experimental data both for microflares and for normal flares. Our study predicts that evidence of plasma heating can be found in flares starting from the A0.0002 X-ray class. Weaker events presumably cannot heat the surrounding plasma. We also estimated emission measures for all flares studied and the thermal energy for 113 events.

  11. Analysis of plasma-mediated ablation in aqueous tissue

    International Nuclear Information System (INIS)

    Jiao Jian; Guo Zhixiong

    2012-01-01

    Plasma-mediated ablation using ultrafast lasers in transparent media such as aqueous tissues is studied. It is postulated that a critical seed free electron density exists due to the multiphoton ionization in order to trigger the avalanche ionization which causes ablation and during the avalanche ionization process the contribution of laser-induced photon ionization is negligible. Based on this assumption, the ablation process can be treated as two separate processes - the multiphoton and avalanche ionizations - at different time stages; so that an analytical solution to the evolution of plasma formation is obtained for the first time. The analysis is applied to plasma-mediated ablation in corneal epithelium and validated via comparison with experimental data available in the literature. The critical seed free-electron density and the time to initiate the avalanche ionization for sub-picosecond laser pulses are analyzed. It is found that the critical seed free-electron density decreases as the pulse width increases, obeying a t p -5.65 rule. This model is further extended to the estimation of crater size in the ablation of tissue-mimic polydimethylsiloxane (PDMS). The results match well with the available experimental measurements.

  12. TFTR/JET INTOR workshop on plasma transport tokamaks

    International Nuclear Information System (INIS)

    Singer, C.E.

    1985-01-01

    This report summarizes the proceedings of a Workshop on transport models for prediction and analysis of tokamak plasma confinement. Summaries of papers on theory, predictive modeling, and data analysis are included

  13. The measurement and analysis of electric fields in glow discharge plasmas

    International Nuclear Information System (INIS)

    Lawler, J.E.; Doughty, D.A.

    1994-01-01

    Interest in glow discharge plasmas has remained high for many decades because of their widespread application as a source of incoherent and coherent light, in plasma processing materials, in pulsed power devices, and in other technologies. Plasma etching of semiconductors and various plasma deposition process emerged as major applications during the 1980s. The technological significance of plasma processing is described in Plasma Processing of Materials. More fundamental work on glow discharges also advanced greatly during the 1980s. For example, substantial progress was made through the use of laser diagnostics to study glow discharges and as a result of the dramatically increased computing power that became available in the 1980s to model glow discharges. Many of the laser diagnostics are described in Radiative Processes in Discharge Plasmas. Kinetic theory models, in particular, became far more sophisticated and realistic during the 1980s. This article is a review of recent work that used optical diagnostics to study electric fields in glow discharge plasmas. Alternative methods for measuring electric electric fields in plasmas include electron beam deflection and electrostatic probes. Optical techniques have important advantages over these methods: They can be used at higher pressures and discharge current densities than electron beam deflection; and they are noninvasive, unlike electrostatic probes. In addition, optical techniques are usually easier to apply in a highly pure system than either of the alternative methods. 46 refs., 23 figs., 1 tab

  14. Effect of liner non-uniformity on plasma instabilities in an inverse Z-pinch magnetized target fusion system: liner-on-plasma simulations and comparison with linear stability analysis

    International Nuclear Information System (INIS)

    Subhash, P V; Madhavan, S; Chaturvedi, S

    2008-01-01

    Two-dimensional (2D) magneto-hydrodynamic (MHD) liner-on-plasma computations have been performed to study the growth of instabilities in a magnetized target fusion system involving the cylindrical compression of an inverse Z-pinch target plasma by a metallic liner. The growth of modes in the plasma can be divided into two phases. During the first phase, the plasma continues to be Kadomtsev stable. The dominant mode in the liner instability is imposed upon the plasma in the form of a growing perturbation. This mode further transfers part of its energy to its harmonics. During the second phase, however, non-uniform implosion of the liner leads to axial variations in plasma quantities near the liner-plasma interface, such that certain regions of the plasma locally violate the Kadomtsev criteria. Further growth ofthe plasma modes is then due to plasma instability. The above numerical study has been complemented with a linear stability analysis for the plasma, the boundary conditions for this analysis being obtained from the liner-on-plasma simulation. The stability of axisymmetric modes in the first phase is found to satisfy the Kadomtsev condition Q 0 1 modes, using equilibrium profiles from the 2D MHD study, shows that their growth rates can exceed those for m=0 by as much as an order of magnitude

  15. Analysis of the flow structure of a turbulent thermal plasma jet

    International Nuclear Information System (INIS)

    Spores, R.A.

    1989-01-01

    The goal of this research project is to attain a better understanding of the fluid mechanics associated with the high temperature jet of a thermal plasma torch. The analysis of a plasma, which has the ability to vaporize anything placed inside it without proper cooling, presents a unique research challenge. Several types of non-intrusive diagnostic techniques has been used to examine the jet from different perspectives. To actually map out the mean gas velocities and turbulence intensities throughout the jet, laser Doppler anemometry has been employed. The plasma gas and entrained air him been seeded separately in order to conditionally sample the two fluids and attain information about the gas mixing process. Both radial and axial turbulence levels have been measured in order to analyze the non-isotropic nature of the jet. A parabolic numerical code has been modified and compared with the obtained experimental results. A new diagnostic technique for plasma torches, which involves the spectral analysis of voltage, optical (temperature), and acoustical (pressure) fluctuations, has been implemented. The acoustical spectrum can provide information about the existence of coherent structures in the flow while the cross correlation of the acoustical signal with the voltage fluctuations can tell one to what extent perturbations of the internal arc affect the external flow. Since temperature is a scalar that is dependent on the flow field, observing temperature fluctuations can likewise help one to understand the mechanics of the flow. Flow visualization of the plasma jet using a high speed video camera has also been undertaken in order to better understand the entrainment process

  16. An analysis of the plasma impurity influx from alkali-metal coatings for fusion reactor applications

    International Nuclear Information System (INIS)

    DeWald, A.B.; Davidson, J.N.; Krauss, A.R.; Gruen, D.M.

    1982-01-01

    Recently, it has been proposed that alkali-metal covered surfaces be applied to magnetic fusion devices as a means of controlling plasma impurity contamination and shielding the substrate from erosion. Monolayer films of alkali metals have been shown to sputter primarily as ions under particle bombardment. Thus, it is thought that a sheath potential and/or magnetic fields encountered by a sputtered ion will return the ion to the surface without entering the plasma. In this paper, we investigate the net wall impurity influx associated with coatings which exhibit substantial secondary ion emission compared with those which sputter only as neutral atoms. Included in the analysis are sputtered substrate atoms. These are sometimes found to be a significant fraction of the total sputtering yield for low-Z alkali monolayers and affect the overall performance of such coatings. Estimates of the impurity influx made in the neighborhood of a sheath potential show that secondary-ion emitting coatings are effective as a means of inhibiting plasma impurity contamination and wall erosion. (orig.)

  17. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  18. Improved break-in-slope analysis of the plasma energy response in tokamaks

    International Nuclear Information System (INIS)

    Lerche, E A; Eester, D van

    2008-01-01

    The break-in-slope method is a simple-although powerful-data analysis technique that is commonly used to determine the power absorption profiles of the plasma species during auxiliary heating experiments in tokamaks. It is based on the study of the energy response of the particles to sudden changes in the external power applied to the plasma. Even though some experimental conditions are favorable for the straightforward application of the break-in-slope analysis in its most simple form (linear fit of the experimental temperature signals), most situations require the retention of additional terms in the linearized energy conservation equation for a successful use of this technique. In this paper, important corrections necessary to extend the applicability of the traditional break-in-slope technique will be presented: (i) the numerical determination of the break-in-slope instants in the plasma energy response allowing the study of indirect (collisional) heating scenarios; (ii) the inclusion of the density variations due to the external power step based on fast density measurements; (iii) the exponential representation of the plasma energy evolution after the power break, describing the saturation of the experimental signals in slow modulation or single power step experiments; (iv) a first assessment of the influence of the change in the radiated power on the break-in-slope results. As will be shown, these corrections are particularly important in low absorption scenarios and in single power step studies, where the change in the external power cannot be considered 'non-perturbative' and the standard break-in-slope analysis usually leads to integrated power levels well below the actual power injected into the plasma

  19. Routine plasma analysis for 2-[18F]fluorotyrosine by SAX-cartridges

    International Nuclear Information System (INIS)

    Kling, P.; Coenen, H.H.; Stoecklin, G.

    1990-01-01

    There is a great necessity for simple, reliable, and fast methods of plasma analysis. While HPLC is generally the most effective method, it is rather time consuming and expensive in a routine setting with numerous plasma samples. The authors have developed a new method for determination of the amino acid analogue 2-[ 18 F]fluorotyrosine using SAX columns (Adsorbex R SAX, 400 mg, Merck). The results obtained agree within 5% with those determined by reverse phase HPLC

  20. RACLETTE: a model for evaluating the thermal response of plasma facing components to slow high power plasma transients. Part I: Theory and description of model capabilities

    Science.gov (United States)

    Raffray, A. René; Federici, Gianfranco

    1997-04-01

    RACLETTE (Rate Analysis Code for pLasma Energy Transfer Transient Evaluation), a comprehensive but relatively simple and versatile model, was developed to help in the design analysis of plasma facing components (PFCs) under 'slow' high power transients, such as those associated with plasma vertical displacement events. The model includes all the key surface heat transfer processes such as evaporation, melting, and radiation, and their interaction with the PFC block thermal response and the coolant behaviour. This paper represents part I of two sister and complementary papers. It covers the model description, calibration and validation, and presents a number of parametric analyses shedding light on and identifying trends in the PFC armour block response to high plasma energy deposition transients. Parameters investigated include the plasma energy density and deposition time, the armour thickness and the presence of vapour shielding effects. Part II of the paper focuses on specific design analyses of ITER plasma facing components (divertor, limiter, primary first wall and baffle), including improvements in the thermal-hydraulic modeling required for better understanding the consequences of high energy deposition transients in particular for the ITER limiter case.

  1. RACLETTE: a model for evaluating the thermal response of plasma facing components to slow high power plasma transients. Pt. I. Theory and description of model capabilities

    International Nuclear Information System (INIS)

    Raffray, A.R.; Federici, G.

    1997-01-01

    For pt.II see ibid., p.101-30, 1997. RACLETTE (Rate Analysis Code for pLasma Energy Transfer Transient Evaluation), a comprehensive but relatively simple and versatile model, was developed to help in the design analysis of plasma facing components (PFCs) under 'slow' high power transients, such as those associated with plasma vertical displacement events. The model includes all the key surface heat transfer processes such as evaporation, melting, and radiation, and their interaction with the PFC block thermal response and the coolant behaviour. This paper represents part I of two sister and complementary papers. It covers the model description, calibration and validation, and presents a number of parametric analyses shedding light on and identifying trends in the PFC armour block response to high plasma energy deposition transients. Parameters investigated include the plasma energy density and deposition time, the armour thickness and the presence of vapour shielding effects. Part II of the paper focuses on specific design analyses of ITER plasma facing components (divertor, limiter, primary first wall and baffle), including improvements in the thermal-hydraulic modeling required for better understanding the consequences of high energy deposition transients in particular for the ITER limiter case. (orig.)

  2. Comparative plasma lipidome between human and cynomolgus monkey: are plasma polar lipids good biomarkers for diabetic monkeys?

    Directory of Open Access Journals (Sweden)

    Guanghou Shui

    Full Text Available BACKGROUND: Non-human primates (NHP are now being considered as models for investigating human metabolic diseases including diabetes. Analyses of cholesterol and triglycerides in plasma derived from NHPs can easily be achieved using methods employed in humans. Information pertaining to other lipid species in monkey plasma, however, is lacking and requires comprehensive experimental analysis. METHODOLOGIES/PRINCIPAL FINDINGS: We examined the plasma lipidome from 16 cynomolgus monkey, Macaca fascicularis, using liquid chromatography coupled with mass spectrometry (LC/MS. We established novel analytical approaches, which are based on a simple gradient elution, to quantify polar lipids in plasma including (i glycerophospholipids (phosphatidylcholine, PC; phosphatidylethanolamine, PE; phosphatidylinositol, PI; phosphatidylglycerol, PG; phosphatidylserine, PS; phosphatidic acid, PA; (ii sphingolipids (sphingomyelin, SM; ceramide, Cer; Glucocyl-ceramide, GluCer; ganglioside mannoside 3, GM3. Lipidomic analysis had revealed that the plasma of human and cynomolgus monkey were of similar compositions, with PC, SM, PE, LPC and PI constituting the major polar lipid species present. Human plasma contained significantly higher levels of plasmalogen PE species (p<0.005 and plasmalogen PC species (p<0.0005, while cynomolgus monkey had higher levels of polyunsaturated fatty acyls (PUFA in PC, PE, PS and PI. Notably, cynomolgus monkey had significantly lower levels of glycosphingolipids, including GluCer (p<0.0005 and GM(3 (p<0.0005, but higher level of Cer (p<0.0005 in plasma than human. We next investigated the biochemical alterations in blood lipids of 8 naturally occurring diabetic cynomolgus monkeys when compared with 8 healthy controls. CONCLUSIONS: For the first time, we demonstrated that the plasma of human and cynomolgus monkey were of similar compositions, but contained different mol distribution of individual molecular species. Diabetic monkeys

  3. Spectrochemical analysis using laser plasma excitation

    International Nuclear Information System (INIS)

    Radziemski, L.J.

    1989-01-01

    This paper reports on analyses of gases, liquids, particles, and surfaces in which laser plasma is used to vaporize and excite a material. The authors present a discussion of the interaction between laser radiation and a solid and some recent analytical results using laser plasma excitation on metals. The use of laser plasmas as an ablation source is also discussed

  4. Noncircular plasma shape analysis in long-pulse current drive experiment in TRIAM-1M

    International Nuclear Information System (INIS)

    Minooka, Mayumi; Kawasaki, Shoji; Jotaki, Eriko; Moriyama, Shin-ichi; Nagao, Akihiro; Nakamura, Kazuo; Hiraki, Naoji; Nakamura, Yukio; Itoh, Satoshi

    1991-01-01

    Plasma cross section was noncircularized and the plasma shape was analyzed in order to study the characteristics of the plasma in long-pulse current drive experiments in high-field superconducting tokamak TRIAM-1M. Filament approximation method was adopted, since on-line processing by data processing computer is possible. The experiments of the noncircularization were carried out during 30-to 60-sec discharges. As a result, it became clear that D-shape plasma of elongation ratio 1.4 was maintained stably. By the analysis the internal inductance and poloidal beta were assessed, and so informations about the plasma current profile and internal pressure were obtained. (author)

  5. A restricted access material for rapid analysis of [11C]-labeled radiopharmaceuticals and their metabolites in plasma

    International Nuclear Information System (INIS)

    Gillings, Nic

    2009-01-01

    Introduction: Analysis of the radioactive components in plasma taken during positron emission tomography (PET) measurements is often vital for the correct quantification of the PET data. The described high-performance liquid chromatography (HPLC) method has been developed to provide a fast, sensitive and robust method for the measurement of plasma samples from PET studies using [ 11 C]-labeled radiopharmaceuticals. Methods: Unadulterated plasma samples were analyzed directly, following a simple filtration, by the use of a small extraction column, containing a restricted access material, combined with a monolithic analysis column in a column-switching HPLC system. Results: Up to 4 ml of plasma was analyzed by this method within 4.5-7 min in a fully automated process. Because of the rapid analysis, a large number of samples could be analyzed during a 90-min PET scan. The extraction column could be used for analysis of up to 500 ml of plasma before replacement was required. Conclusions: The described method is fast and robust and the large sample volumes allow for accurate determination of the radioactive components in plasma even at 90 min after injection of a [ 11 C]-labeled radiopharmaceutical.

  6. Observation and analysis of abrupt changes in the interplanetary plasma velocity and magnetic field.

    Science.gov (United States)

    Martin, R. N.; Belcher, J. W.; Lazarus, A. J.

    1973-01-01

    This paper presents a limited study of the physical nature of abrupt changes in the interplanetary plasma velocity and magnetic field based on 19 day's data from the Pioneer 6 spacecraft. The period was chosen to include a high-velocity solar wind stream and low-velocity wind. Abrupt events were accepted for study if the sum of the energy density in the magnetic field and velocity changes was above a specified minimum. A statistical analysis of the events in the high-velocity solar wind stream shows that Alfvenic changes predominate. This conclusion is independent of whether steady state requirements are imposed on conditions before and after the event. Alfvenic changes do not dominate in the lower-speed wind. This study extends the plasma field evidence for outwardly propagating Alfvenic changes to time scales as small as 1 min (scale lengths on the order of 20,000 km).

  7. Analysis of 6-mercaptopurine in human plasma with a high-performance liquid chromatographic method including post-column derivatization and fluorimetric detection

    NARCIS (Netherlands)

    Jonkers, R. E.; Oosterhuis, B.; ten Berge, R. J.; van Boxtel, C. J.

    1982-01-01

    A relatively simple assay with improved reliability and sensitivity for measuring levels of 6-mercaptopurine in human plasma is presented. After extraction of the compound and the added internal standard with phenyl mercury acetate, samples were separated by ion-pair reversed-phase high-performance

  8. Screening of plasma biomarkers in patients with unstable angina pectoris with proteomics analysis

    Directory of Open Access Journals (Sweden)

    Shui-wang HU

    2017-08-01

    Full Text Available Objective To analyze and compare the differentially expressed plasma proteins between patients with stable angina pectoris (SAP and unstable angina pectoris (UAP, and search for the biomarkers that maybe used for early diagnosis of UAP. Methods Sixty plasma samples were collected respectively from normal controls group (N group, SAP group and UAP group during Jun. 2014 to Apr. 2015 from the Third Affiliated Hospital of Southern Medical University. Ten samples (100μl of each group were selected randomly to pool into 3 groups severally. After removing high-abundance proteins from plasma, two- dimensional difference gel electrophoresis (DIGE was used to isolate the total proteins, and then the protein spots with more than 2-fold changes between UAP and SAP were picked up after the differential software analysis. Afterward, the varied proteins were identified by matrix assisted laser desorption ionization-time of flight/time of flight (MALDI-TOF/TOF mass spectrometry (MS. Finally, 40 plasma samples were collected respectively from N, SAP and UAP group, and the UAP specific differential proteins were selected to be verified by ELISA. Results A total of 10 varied protein spots with more than 2-fold changes in UAP and SAP were found including 9 up-regulated proteins and 1 down-regulated one. MS identification indicated that the up-regulated proteins included fibrinogen gamma chain (FGG, complement C4-B (C4B, immunoglobulin (Ig kappa chain C region (IGKC and hemoglobin subunit alpha (HBA1, whereas the down-regulated one was haptoglobin (HP. After comparing the varied proteins with that in N group, 2 specifically UAP-related proteins, IGKC and HP, were detected totally. IGKC was selected to validate by ELISA, and the corresponding results showed that IGKC was increased specifically in UAP plasma (P<0.05 when compared with N and SAP group, which was consistent with DIGE. Conclusion IGKC and HP have been detected as specifically related proteins to UAP

  9. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Harilal, Sivanandan S.; Brumfield, Brian E.; LaHaye, Nicole L.; Hartig, Kyle C.; Phillips, Mark C.

    2018-04-20

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  10. Contributions to mathematical analysis and to numerical approximation in plasma physics

    International Nuclear Information System (INIS)

    Besse, N.

    2009-01-01

    The author's scientific works deal with numerical analysis and the simulation of the partial differential equations that intervene in the transport of charged particles and in plasma physics. In the chapters 2 and 3, a reduction of the Vlasov equation is presented, this method is based on the Liouville geometric invariants and it leads to a mathematical model named water-bag model that can be coupled with various equations of the electromagnetic field: the Poisson equation, the quasi-neutral equation or Maxwell equations. In the chapter 3 this reduction method is applied to the Vlasov gyro-kinetic equation to form the gyro-water-bag model. The mathematical analysis of this model produces interesting analytical results such as: threshold instabilities, instability growth rate, transport coefficient and non-linear turbulence mechanisms. Simulations have been performed to study turbulence in magnetized plasmas. In these plasmas occurred numerous instabilities due to the presence of high density and temperature gradients. These instabilities generate turbulence that deteriorates plasma confinement conditions required for thermonuclear fusion. The numerical calculation of turbulent thermal diffusivities is important since confinement time is determined by these transport coefficients. The chapter 4 gathers mathematical analysis issues like convergence or prior knowledge of errors concerning several high-order numerical methods used to solve Vlasov-Poisson or Vlasov-Einstein equation systems as well as the induction equation of an idealistic MHD system. The chapter 5 presents original numerical methods to solve several non-linear Vlasov equations such as Vlasov-Poisswell, Vlasov-Darwin, Vlasov-Maxwell and Vlasov-gyrokinetic that are involved either in inertial fusion or in magnetic confinement fusion

  11. A simple model of the plasma deflagration gun including self-consistent electric and magnetic fields

    International Nuclear Information System (INIS)

    Enloe, C.L.; Reinovsky, R.E.

    1985-01-01

    At the Air Force Weapons Laboratory, interest has continued for some time in energetic plasma injectors. A possible scheme for such a device is the plasma deflagration gun. When the question arose whether it would be possible to scale a deflagration gun to the multi-megajoule energy level, it became clear that a scaling law which described the fun as a circuit element and allowed one to confidently scale gun parameters would be required. The authors sought to develop a scaling law which self-consistently described the current, magnetic field, and velocity profiles in the gun. They based this scaling law on plasma parameters exclusively, abandoning the fluid approach

  12. Comparison of plasma/serum levels of procalcitonin between infection and febrile disease flare in patients with systemic lupus erythematosus: a meta-analysis.

    Science.gov (United States)

    Liu, Li-Na; Wang, Peng; Guan, Shi-Yang; Li, Xiao-Mei; Li, Bao-Zhu; Leng, Rui-Xue; Pan, Hai-Feng

    2017-12-01

    Currently published data regarding the potential role of procalcitonin (PCT) for the discrimination between systemic lupus erythematosus (SLE) flare and infection are contradictory. To derive a more precise evaluation, a meta-analysis was performed. Published literatures from PubMed, Embase, and the Cochrane Library were obtained. The Newcastle-Ottawa Scale was used to assess the study quality. Pooled standard mean difference (SMD) with 95% confidence interval (CI) was calculated by random-effect model analysis. Heterogeneity test was performed by the Q statistic and quantified using I 2 . Eight studies including 205 SLE flare patients and 198 SLE patients with infection were finally incorporated in the meta-analysis after examining title, type, abstracts, and full text. No significant differences in plasma/serum PCT levels were found between SLE patients with flare and SLE patients with infection when all studies were pooled into the meta-analysis (pooled SMD = - 0.45, 95% CI = - 0.96 to 0.06). However, subgroup analysis showed that Asian SLE patients with infection had higher plasma/serum PCT levels when compared with SLE patients with flare (p infection. However, plasma/serum PCT levels are significantly higher in Asian SLE patients with infection.

  13. An engineering and economic analysis: Inductively coupled plasma mobile treatment of hazardous waste

    International Nuclear Information System (INIS)

    Detering, B.A.; McLlwain, M.E.

    1997-10-01

    This analysis considers the engineering and economic viability of an rf-plasma, mobile treatment process for remediation of hazardous waste located at remote sites in Alaska. A simple engineering process flowsheet is used to define the elements associated with the process and to identify major pieces of equipment. The proposed flowsheet and equipment are used to estimate capital and operational costs for four separate processing cases. These cases explore various operational situations, including moving equipment to a remote site, transporting wastes to a base site, and varying operational periods. Some cases consider variations in fuel costs known to exist across Alaska. Operational costs, capital equipment costs, and revenues are used to calculate pro-forma income statements. These income statements are used to predict economic viability. Based on the economic viability, the analysis suggests that processing of hydrocarbon-contaminated soils is more profitable when performed at remote sites as compared to at a home base. Processing of poly-chloro-biphenyl (PCB)-contaminated oil at a stationary site is more profitable as compared to remote treatment due to the cost of transporting the equipment. Over the range of fuel prices considered, higher fuel costs increase the per unit treatment price by ten percent. Based on the results of this analysis, an rf-plasma based process appears to be economically viable for remote treatment of hydrocarbon-contaminated soil, but less viable for treatment of PCB-contaminated oil

  14. High-resolution Thomson scattering system on the COMPASS tokamak: Evaluation of plasma parameters and error analysis

    Czech Academy of Sciences Publication Activity Database

    Aftanas, Milan; Böhm, Petr; Bílková, Petra; Weinzettl, Vladimír; Zajac, Jaromír; Žáček, František; Stöckel, Jan; Hron, Martin; Pánek, Radomír; Scannell, R.; Walsh, M.

    2012-01-01

    Roč. 83, č. 10 (2012), 10E350-10E350 ISSN 0034-6748. [Topical Conference High-Temperature Plasma Diagnostics/19./. Monterey, 06.05.2012-10.05.2012] R&D Projects: GA ČR GA202/09/1467; GA MŠk 7G10072 Institutional research plan: CEZ:AV0Z20430508 Keywords : error analysis * Monte Carlo methods * plasma density * plasma diagnostics * plasma temperature * plasma toroidal confinement * Tokamak devices Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.602, year: 2012 http://dx.doi.org/10.1063/1.4743956

  15. DbAccess: Interactive Statistics and Graphics for Plasma Physics Databases

    International Nuclear Information System (INIS)

    Davis, W.; Mastrovito, D.

    2003-01-01

    DbAccess is an X-windows application, written in IDL(reg s ign), meeting many specialized statistical and graphical needs of NSTX [National Spherical Torus Experiment] plasma physicists, such as regression statistics and the analysis of variance. Flexible ''views'' and ''joins,'' which include options for complex SQL expressions, facilitate mixing data from different database tables. General Atomics Plot Objects add extensive graphical and interactive capabilities. An example is included for plasma confinement-time scaling analysis using a multiple linear regression least-squares power fit

  16. Introduction to plasma physics with space, laboratory and astrophysical applications

    CERN Document Server

    Gurnett, Donald A

    2017-01-01

    Introducing basic principles of plasma physics and their applications to space, laboratory and astrophysical plasmas, this new edition provides updated material throughout. Topics covered include single-particle motions, kinetic theory, magnetohydrodynamics, small amplitude waves in hot and cold plasmas, and collisional effects. New additions include the ponderomotive force, tearing instabilities in resistive plasmas and the magnetorotational instability in accretion disks, charged particle acceleration by shocks, and a more in-depth look at nonlinear phenomena. A broad range of applications are explored: planetary magnetospheres and radiation belts, the confinement and stability of plasmas in fusion devices, the propagation of discontinuities and shock waves in the solar wind, and analysis of various types of plasma waves and instabilities that can occur in planetary magnetospheres and laboratory plasma devices. With step-by-step derivations and self-contained introductions to mathematical methods, this book...

  17. Analysis of the biological effects of a non-thermal plasma on saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Park, Gyung S.; Baik, Ku Y.; Kim, Jung G.; Kim, Yun J.; Lee, Kyung A.; Jung, Ran J.; Cho, Guang S.

    2012-01-01

    The cellular and the molecular responses of eukaryotic yeast (Saccharomyces cerevisiae) to a non-thermal plasma at atmospheric pressure are analyzed. A plasma device with a dielectric barrier discharge is used in order to understand the mechanisms of the plasma action on eukaryotic microbes. When the yeast cells are exposed to a plasma (at a 2-mm distance) and then cultured on a YPD (yeast extract, peptone, and dextrose) - agar plate, the number of surviving cells is reduced over exposure time. More than a 50% reduction in number is observed after two exposures of 5 minutes' duration. In addition, very small whitish colonies appear after the two exposures. The microscopic analysis indicates that the yeast cells treated with this plasma exposure have rough and shrunken shapes in comparison to the oval shapes with smooth surfaces of the control cells. The profile of proteins analyzed by using 2-dimentional electrophoresis demonstrates that the level of proteins with high molecular weights is increased in plasma-treated cells.

  18. Generalized MHD for numerical stability analysis of high-performance plasmas in tokamaks

    International Nuclear Information System (INIS)

    Mikhailovskii, A.B.

    1998-01-01

    A set of generalized magnetohydrodynamic (MHD) equations is formulated to accommodate the effects associated with high ion and electron temperatures in high-performance plasmas in tokamaks. The effects of neoclassical bootstrap current, neoclassical ion viscosity, the ion finite Larmor radius effect and electron and ion drift effects are taken into account in two-fluid MHD equations together with gyroviscosity, parallel viscosity, electron parallel inertia and collisionless ion heat flux. The ion velocity is identified as the plasma velocity, while the electron velocity is expressed in terms of the plasma velocity and electric current. Ion and electron momentum equations are combined to give the plasma momentum equation. The perpendicular (with respect to the equilibrium magnetic field) ion momentum equation is used as perpendicular Ohm's law and the parallel electron momentum equation - as parallel Ohm's law. Perpendicular Ohm's law allows for the Hall and ion drift effects. Parallel Ohm's law includes the electron drift effect, collisionless skin effect and bootstrap current. In addition, both perpendicular and parallel Ohm's laws contain the resistivity. Due to the quasineutrality condition, the ions and electrons are characterized by the same number density which is described by the ion continuity equation. On the other hand, the ion and electron temperatures are allowed to be different. The ion temperature is described by the ion energy equation allowing for the oblique heat flux, in addition to the perpendicular ion heat flux. The electron temperature is determined by the condition of high parallel electron heat conductivity. The ion and electron parallel viscosities are represented in a form valid for all the collisionality regimes (Pfirsch-Schluter, plateau, and banana). An optimized form of the generalized MHD equations is then represented in terms of the toroidal coordinate system used in the JET equilibrium and stability codes. The derived equations

  19. Electromagnetic analysis of the plasma chamber of an ECR-based charge breeder

    Science.gov (United States)

    Galatà, A.; Patti, G.; Celona, L.; Mascali, D.; Neri, L.; Torrisi, G.

    2016-02-01

    The optimization of the efficiency of an ECR-based charge breeder is a twofold task: efforts must be paid to maximize the capture of the injected 1+ ions by the confined plasma and to produce high charge states to allow post-acceleration at high energies. Both tasks must be faced by studying in detail the electrons heating dynamics, influenced by the microwave-to-plasma coupling mechanism. Numerical simulations are a powerful tools for obtaining quantitative information about the wave-to-plasma interaction process: this paper presents a numerical study of the microwaves propagation and absorption inside the plasma chamber of the PHOENIX charge breeder, which the selective production of exotic species project, under construction at Legnaro National Laboratories, will adopt as charge breeder. Calculations were carried out with a commercial 3D FEM solver: first, all the resonant frequencies were determined by considering a simplified plasma chamber; then, the realistic geometry was taken into account, including a cold plasma model of increasing complexity. The results gave important information about the power absorption and losses and will allow the improvement of the plasma model to be used in a refined step of calculation reproducing the breeding process itself.

  20. Electromagnetic analysis of the plasma chamber of an ECR-based charge breeder

    International Nuclear Information System (INIS)

    Galatà, A.; Patti, G.; Celona, L.; Mascali, D.; Neri, L.; Torrisi, G.

    2016-01-01

    The optimization of the efficiency of an ECR-based charge breeder is a twofold task: efforts must be paid to maximize the capture of the injected 1+ ions by the confined plasma and to produce high charge states to allow post-acceleration at high energies. Both tasks must be faced by studying in detail the electrons heating dynamics, influenced by the microwave-to-plasma coupling mechanism. Numerical simulations are a powerful tools for obtaining quantitative information about the wave-to-plasma interaction process: this paper presents a numerical study of the microwaves propagation and absorption inside the plasma chamber of the PHOENIX charge breeder, which the selective production of exotic species project, under construction at Legnaro National Laboratories, will adopt as charge breeder. Calculations were carried out with a commercial 3D FEM solver: first, all the resonant frequencies were determined by considering a simplified plasma chamber; then, the realistic geometry was taken into account, including a cold plasma model of increasing complexity. The results gave important information about the power absorption and losses and will allow the improvement of the plasma model to be used in a refined step of calculation reproducing the breeding process itself

  1. Plasma resistivity in a slow rising current theta-pinch device

    International Nuclear Information System (INIS)

    Kayama, Milton Eiji; Dobrowolsky, Marcelo Shubert; Honda, Roberto Yzumi; Aramaki, Emilia Akemi; Algatti, Mauricio Antonio

    1998-01-01

    Anomalous behavior of plasma resistivity was observed in a Theta-pinch plasma. A comparative analysis was performed with a hybrid numerical code where the Chodura s resistivity algorithm is included. Good agreement was found in the radial plasma dynamic description. The experimental value of resistivity at null field point was found to be one order of magnitude greater than the theoretical prediction. (author)

  2. Analysis of tokamak plasma confinement modes using the fast Fourier transformation

    International Nuclear Information System (INIS)

    Mirmoeini, S.R.; Salar Elahi, A.; Ghoranneviss, M.

    2016-01-01

    The Fourier analysis is a satisfactory technique for detecting plasma confinement modes in tokamaks. The confinement mode of tokamak plasma was analysed using the fast Fourier transformation (FFT). For this purpose, we used the data of Mirnov coils that is one of the identifying tools in the IR-T1 tokamak, with and without external field (electric biasing), and then compared it with each other. After the Fourier analysis of Mirnov coil data, the diagram of power spectrum density was depicted in different angles of Mirnov coils in the 'presence of external field' as well as in the 'absence of external field'. The power spectrum density (PSD) interprets the manner of power distribution of a signal with frequency. In this article, the number of plasma modes and the safety factor q were obtained by using the mode number of q = m/n (m is the mode number). The maximum MHD activity was obtained in 30-35 kHz frequency, using the density of the energy spectrum. In addition, the number of different modes across 0-35 ms time was compared with each other in the presence and absence of the external field. (author)

  3. Elevated GM3 plasma concentration in idiopathic Parkinson's disease: A lipidomic analysis.

    Directory of Open Access Journals (Sweden)

    Robin B Chan

    Full Text Available Parkinson's disease (PD is a common neurodegenerative disease whose pathological hallmark is the accumulation of intracellular α-synuclein aggregates in Lewy bodies. Lipid metabolism dysregulation may play a significant role in PD pathogenesis; however, large plasma lipidomic studies in PD are lacking. In the current study, we analyzed the lipidomic profile of plasma obtained from 150 idiopathic PD patients and 100 controls, taken from the 'Spot' study at Columbia University Medical Center in New York. Our mass spectrometry based analytical panel consisted of 520 lipid species from 39 lipid subclasses including all major classes of glycerophospholipids, sphingolipids, glycerolipids and sterols. Each lipid species was analyzed using a logistic regression model. The plasma concentrations of two lipid subclasses, triglycerides and monosialodihexosylganglioside (GM3, were different between PD and control participants. GM3 ganglioside concentration had the most significant difference between PD and controls (1.531±0.037 pmol/μl versus 1.337±0.040 pmol/μl respectively; p-value = 5.96E-04; q-value = 0.048; when normalized to total lipid: p-value = 2.890E-05; q-value = 2.933E-03. Next, we used a collection of 20 GM3 and glucosylceramide (GlcCer species concentrations normalized to total lipid to perform a ROC curve analysis, and found that these lipids compare favorably with biomarkers reported in previous studies (AUC = 0.742 for males, AUC = 0.644 for females. Our results suggest that higher plasma GM3 levels are associated with PD. GM3 lies in the same glycosphingolipid metabolic pathway as GlcCer, a substrate of the enzyme glucocerebrosidase, which has been associated with PD. These findings are consistent with previous reports implicating lower glucocerebrosidase activity with PD risk.

  4. Proteomic plasma membrane profiling reveals an essential role for gp96 in the cell surface expression of LDLR family members, including the LDL receptor and LRP6.

    Science.gov (United States)

    Weekes, Michael P; Antrobus, Robin; Talbot, Suzanne; Hör, Simon; Simecek, Nikol; Smith, Duncan L; Bloor, Stuart; Randow, Felix; Lehner, Paul J

    2012-03-02

    The endoplasmic reticulum chaperone gp96 is required for the cell surface expression of a narrow range of proteins, including toll-like receptors (TLRs) and integrins. To identify a more comprehensive repertoire of proteins whose cell surface expression is dependent on gp96, we developed plasma membrane profiling (PMP), a technique that combines SILAC labeling with selective cell surface aminooxy-biotinylation. This approach allowed us to compare the relative abundance of plasma membrane (PM) proteins on gp96-deficient versus gp96-reconstituted murine pre-B cells. Analysis of unfractionated tryptic peptides initially identified 113 PM proteins, which extended to 706 PM proteins using peptide prefractionation. We confirmed a requirement for gp96 in the cell surface expression of certain TLRs and integrins and found a marked decrease in cell surface expression of four members of the extended LDL receptor family (LDLR, LRP6, Sorl1 and LRP8) in the absence of gp96. Other novel gp96 client proteins included CD180/Ly86, important in the B-cell response to lipopolysaccharide. We highlight common structural motifs in these client proteins that may be recognized by gp96, including the beta-propeller and leucine-rich repeat. This study therefore identifies the extended LDL receptor family as an important new family of proteins whose cell surface expression is regulated by gp96.

  5. Analysis of human blood plasma cell-free DNA fragment size distribution using EvaGreen chemistry based droplet digital PCR assays.

    Science.gov (United States)

    Fernando, M Rohan; Jiang, Chao; Krzyzanowski, Gary D; Ryan, Wayne L

    2018-04-12

    Plasma cell-free DNA (cfDNA) fragment size distribution provides important information required for diagnostic assay development. We have developed and optimized droplet digital PCR (ddPCR) assays that quantify short and long DNA fragments. These assays were used to analyze plasma cfDNA fragment size distribution in human blood. Assays were designed to amplify 76,135, 490 and 905 base pair fragments of human β-actin gene. These assays were used for fragment size analysis of plasma cell-free, exosome and apoptotic body DNA obtained from normal and pregnant donors. The relative percentages for 76, 135, 490 and 905 bp fragments from non-pregnant plasma and exosome DNA were 100%, 39%, 18%, 5.6% and 100%, 40%, 18%,3.3%, respectively. The relative percentages for pregnant plasma and exosome DNA were 100%, 34%, 14%, 23%, and 100%, 30%, 12%, 18%, respectively. The relative percentages for non-pregnant plasma pellet (obtained after 2nd centrifugation step) were 100%, 100%, 87% and 83%, respectively. Non-pregnant Plasma cell-free and exosome DNA share a unique fragment distribution pattern which is different from pregnant donor plasma and exosome DNA fragment distribution indicating the effect of physiological status on cfDNA fragment size distribution. Fragment distribution pattern for plasma pellet that includes apoptotic bodies and nuclear DNA was greatly different from plasma cell-free and exosome DNA. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Parametric analysis of the thermal effects on the divertor in tokamaks during plasma disruptions

    International Nuclear Information System (INIS)

    Bruhn, M.L.

    1988-04-01

    Plasma disruptions are an ever present danger to the plasma-facing components in today's tokamak fusion reactors. This threat results from our lack of understanding and limited ability to control this complex phenomenon. In particular, severe energy deposition occurs on the divertor component of the double-null configured tokamak reactor during such disruptions. A hybrid computational model developed to estimate and graphically illustrate global thermal effects of disruptions on the divertor plates is described in detail. The quasi-two-dimensional computer code, TADDPAK (Thermal Analysis Divertor during Disruptions PAcKage), is used to conduct parametric analysis for the TIBER II Tokamak Engineering Test Reactor Design. The dependence of these thermal effects on divertor material choice, disruption pulse length, disruption pulse shape, and the characteristic thickness of the plasma scrape-off layer is investigated for this reactor design. Results and conclusions from this analysis are presented. Improvements to this model and issues that require further investigation are discussed. Cursory analysis for ITER (International Thermonuclear Experimental Reactor) is also presented in the appendix. 75 refs., 49 figs., 10 tabs

  7. Determination of selenium and zinc in rat plasma by instrumental neutron activation analysis; Determinacion de selenio y zinc en plasma mediante analisis por activacion neutronica instrumental

    Energy Technology Data Exchange (ETDEWEB)

    Munoz A, Luis

    1998-12-31

    To evaluate the effects on the thyroid function when simple or multiple zinc, selenium and iodine deficiency are induced, research was carried out in laboratory animals. For simultaneously determining the Zn and Se concentration in rat plasma, an instrumental neutron activation analysis technique was applied. A clean laboratory, was used for the preparation of samples. High purity materials were used for sample collection and storage. Irradiation, decay and counting parameters were optimized to obtain the best sensitivity, accuracy and precision analysis. The Zn and Se concentrations were determined from the peak area of gamma-rays of 1115 and 265 KeV respectively. The analytical methodology used was validated with standard reference materials. The procedure used for the analysis, including the phases of collection, treatment of the samples and analytical determination was considered suitable for the study of trace elements in biological samples, especially plasma. (author). Dissertation to obtain the title of Bachelor in Chemistry; 46 refs., 12 figs., 17 tabs. [Espanol] Con el proposito de evaluar los efectos que se producen sobre la funcion tiroidea cuando se induce un deficiencia simple o multiple de zinc, selenio y yodo, se llevo a cabo una investigacion en animales de experimentacion. Se aplico la tecnica de analises por activacion neutronica instrumental para la determinacion de Se y Zn en plasma de ratas. Se utilizo un laboratorio limpio clase 100 para la preparacion de las muestras y se emplearon materiales de alta pureza para su recoleccion y almacenamiento. Se optimizaron los parametros de irradiacion, decaimiento y conteo de las muestras con el proposito de alcanzar la mejor sensibilidad, exactitud y precision analitica. Las concentracion de Se y Zn fueron determinadas evaluando las areas de los fotopicos de 265 y 1115 KeV respectivamente. El metodo analitico fue validado utilizando materiales de referencia. El procedimiento utilizado para el analisis

  8. Plasma taurine levels are not affected by vigabatrin in pediatric patients.

    Science.gov (United States)

    Spelbrink, Emily M; Mabud, Tarub S; Reimer, Richard; Porter, Brenda E

    2016-08-01

    Vigabatrin is a highly effective antiseizure medication, but its use is limited due to concerns about retinal toxicity. One proposed mechanism for this toxicity is vigabatrin-mediated reduction of taurine. Herein we assess plasma taurine levels in a retrospective cohort of children with epilepsy, including a subset receiving vigabatrin. All children who underwent a plasma amino acid analysis as part of their clinical evaluation between 2006 and 2015 at Stanford Children's Health were included in the analysis. There were no significant differences in plasma taurine levels between children taking vigabatrin (n = 16), children taking other anti-seizure medications, and children not taking any anti-seizure medication (n = 556) (analysis of variance [ANOVA] p = 0.841). There were, however, age-dependent decreases in plasma taurine levels. Multiple linear regression revealed no significant association between vigabatrin use and plasma taurine level (p = 0.87) when controlling for age. These results suggest that children taking vigabatrin maintain normal plasma taurine levels, although they leave unanswered whether taurine supplementation is necessary or sufficient to prevent vigabatrin-associated visual field loss. They also indicate that age should be taken into consideration when evaluating taurine levels in young children. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  9. Plasma and oscillations with contributions in memoriam including a complete bibliography of his works

    CERN Document Server

    Suits, C Guy

    1961-01-01

    The Collected Works of Irving Langmuir, Volume 5: Plasma and Oscillations is an 11-chapter text covers the extensive research study of Langmuir in the field of gas discharges. This book specifically tackles oscillations in ionized gases. The opening chapters describe the plasma-boundary phenomena and the use of a probe to separate the primary electron beam from the scattered electrons. The succeeding chapters deal with the collisions between electrons and gas molecules, oscillations in ionized gases, and the interaction of electron and positive ion space charges in cathode sheaths. These t

  10. An assessment of surface emissivity variation effects on plasma uniformity analysis using IR cameras

    Science.gov (United States)

    Greenhalgh, Abigail; Showers, Melissa; Biewer, Theodore

    2017-10-01

    The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device operating at Oak Ridge National Laboratory (ORNL). Its purpose is to test plasma source and heating concepts for the planned Material Plasma Exposure eXperiment (MPEX), which has the mission to test the plasma-material interactions under fusion reactor conditions. In this device material targets will be exposed to high heat fluxes (>10 MW/m2). To characterize the heat fluxes to the target a IR thermography system is used taking up to 432 frames per second videos. The data is analyzed to determine the surface temperature on the target in specific regions of interest. The IR analysis has indicated a low level of plasma uniformity; the plasma often deposits more heat to the edge of the plate than the center. An essential parameter for IR temperature calculation is the surface emissivity of the plate (stainless steel). A study has been performed to characterize the variation in the surface emissivity of the plate as its temperature changes and its surface finish is modified by plasma exposure.

  11. Direct atomic spectrometric analysis by slurry atomisation: Pt. 7. Analysis of coal using inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ebdon, Les; Foulkes, M E; Parry, H G.M.; Tye, C T

    1988-09-01

    The application of slurry atomisation - inductively coupled plasma mass spectrometry (ICP-MS) to major, minor and trace element determination in coals has been investigated. Eight certified reference material (CRM) coals have been ground by the bottle and bead method and analysed using both rapid scan semi-quantitative analysis, employing a single rhodium internal standard, and full quantitative analysis using simple aqueous standards for calibration. The semi-quantitative mode, which determines the concentration using the mass-response curve for 68 elements against the single internal standard, produced values which were within a factor of two of the certified reference value, in most instances. The full quantitative determination gave excellent agreement with the certified reference material coals for a large number of elemental constituents. The results from the determination of 16 elements of interest are discussed including the effects of polyatomic interferents and isotope sensitivity.

  12. New electromagnetic particle simulation code for the analysis of spacecraft-plasma interactions

    International Nuclear Information System (INIS)

    Miyake, Yohei; Usui, Hideyuki

    2009-01-01

    A novel particle simulation code, the electromagnetic spacecraft environment simulator (EMSES), has been developed for the self-consistent analysis of spacecraft-plasma interactions on the full electromagnetic (EM) basis. EMSES includes several boundary treatments carefully coded for both longitudinal and transverse electric fields to satisfy perfect conductive surface conditions. For the longitudinal component, the following are considered: (1) the surface charge accumulation caused by impinging or emitted particles and (2) the surface charge redistribution, such that the surface becomes an equipotential. For item (1), a special treatment has been adopted for the current density calculated around the spacecraft surface, so that the charge accumulation occurs exactly on the surface. As a result, (1) is realized automatically in the updates of the charge density and the electric field through the current density. Item (2) is achieved by applying the capacity matrix method. Meanwhile, the transverse electric field is simply set to zero for components defined inside and tangential to the spacecraft surfaces. This paper also presents the validation of EMSES by performing test simulations for spacecraft charging and peculiar EM wave modes in a plasma sheath.

  13. Interferometric analysis of laboratory photoionized plasmas utilizing supersonic gas jet targets.

    Science.gov (United States)

    Swanson, Kyle James; Ivanov, Vladimir; Mancini, Roberto; Mayes, Daniel C.

    2018-06-01

    Photoionized plasmas are an important component of active galactic nuclei, x-ray binary systems and other astrophysical objects. Laboratory produced photoionized plasmas have mainly been studied at large scale facilities, due to the need for high intensity broadband x-ray flux. Using supersonic gas jets as targets has allowed university scale pulsed power generators to begin similar research. The two main advantages of this approach with supersonic gas jets include: possibility of a closer location to the x-ray source and no attenuation related to material used for containment and or tamping. Due to these factors, this experimental platform creates a laboratory environment that more closely resembles astrophysical environments. This system was developed at the Nevada Terawatt Facility using the 1 MA pulsed power generator Zebra. Neon, argon, and nitrogen supersonic gas jets are produced approximately 7-8mm from the z-pinch axis. The high intensity broadband x-ray flux produced by the collapse of the z-pinch wire array implosion irradiates the gas jet. Cylindrical wire arrays are made with 4 and 8 gold 10µm thick wire. The z-pinch radiates approximately 12-16kj of x-ray energy, with x-ray photons under 1Kev in energy. The photoionized plasma is measured via x-ray absorption spectroscopy and interferometry. A Mach-Zehnder interferometer is used to the measure neutral density of the jet prior to the zebra shot at a wavelength of 266 nm. A dual channel air-wedge shearing interferometer is used to measure electron density of the ionized gas jet during the shot, at wavelengths of 532nm and 266nm. Using a newly developed interferometric analysis tool, average ionization state maps of the plasma can be calculated. Interferometry for nitrogen and argon show an average ionization state in the range of 3-8. Preliminary x-ray absorption spectroscopy collected show neon absorption lines. This work was sponsored in part by DOE Office of Science Grant DE-SC0014451.

  14. Comparative Analysis of Carbon Plasma in Arc and RF Reactors

    International Nuclear Information System (INIS)

    Todorovic-Markovic, B.; Markovic, Z.; Mohai, I.; Szepvolgyi, J.

    2004-01-01

    Results on studies of molecular spectra emitted in the initial stages of fullerene formation during the processing of graphite powder in induction RF reactor and evaporation of graphite electrodes in arc reactor are presented in this paper. It was found that C2 radicals were dominant molecular species in both plasmas. C2 radicals have an important role in the process of fullerene synthesis. The rotational-vibrational temperatures of C2 and CN species were calculated by fitting the experimental spectra to the simulated ones. The results of optical emission study of C2 radicals generated in carbon arc plasma have shown that rotational temperature of C2 species depends on carbon concentration and current intensity significantly. The optical emission study of induction RF plasma and SEM analysis of graphite powder before and after plasma treatment have shown that evaporation of the processed graphite powder depends on feed rate and composition of gas phase significantly. Based on the obtained results, it was concluded that in the plasma region CN radicals could be formed by the reaction of C2 species with atomic nitrogen at smaller loads. At larger feed rate of graphite powder, CN species were produced by surface reaction of the hot carbon particles with nitrogen atoms. The presence of nitrogen in induction RF plasma reduces the fullerene yield significantly. The fullerene yield obtained in two different reactors was: 13% in arc reactor and 4.1% in induction RF reactor. However, the fullerene production rate was higher in induction RF reactor-6.4 g/h versus 1.7 g/h in arc reactor

  15. Foundations of atmospheric pressure non-equilibrium plasmas

    Science.gov (United States)

    Bruggeman, Peter J.; Iza, Felipe; Brandenburg, Ronny

    2017-12-01

    Non-equilibrium plasmas have been intensively studied over the past century in the context of material processing, environmental remediation, ozone generation, excimer lamps and plasma display panels. Research on atmospheric pressure non-equilibrium plasmas intensified over the last two decades leading to a large variety of plasma sources that have been developed for an extended application range including chemical conversion, medicine, chemical analysis and disinfection. The fundamental understanding of these discharges is emerging but there remain a lot of unexplained phenomena in these intrinsically complex plasmas. The properties of non-equilibrium plasmas at atmospheric pressure span over a huge range of electron densities as well as heavy particle and electron temperatures. This paper provides an overview of the key underlying processes that are important for the generation and stabilization of atmospheric pressure non-equilibrium plasmas. The unique physical and chemical properties of theses discharges are also summarized.

  16. Analysis of two human parvovirus PARV4 genotypes identified in human plasma for fractionation

    NARCIS (Netherlands)

    Fryer, Jacqueline F.; Delwart, Eric; Bernardin, Flavien; Tuke, Philip W.; Lukashov, Vladimir V.; Baylis, Sally A.

    2007-01-01

    The presence of the novel parvovirus PARV4 and a related variant, PARV5, was recently demonstrated in pooled plasma used in the manufacture of blood and plasma-derived medicinal products. DNA sequence analysis of nearly full-length genomes of four PARV4 and two PARV5 strains from manufacturing

  17. Towards structural and functional analysis of the plant plasma membrane proton pump

    DEFF Research Database (Denmark)

    Justesen, Bo Højen

    The plasma membrane H+-ATPase is a proton pump essential for several physiological important processes in plants. Through the extrusion of protons from the cell, the PM H+-ATPase establishes and maintains a proton gradient used by proton coupled transporters and secondary active transport...... of nutrients and metabolites across the plasma membrane. Additional processes involving the PM H+-ATPase includes plant growth, development, and response to biotic and abiotic stresses. Extensive efforts have been made in attempts to elucidate the detailed physiological role and biochemical characteristics...... of plasma membrane H+-ATPases. Studies on the plasma membrane H+-ATPases have involved both in vivo and in vitro approaches, with the latter employing either solubilisation by detergent micelles, or reconstitution into lipid vesicles. Despite resulting in a large body of information on structure, function...

  18. Increased plasma proline concentrations are associated with sarcopenia in the elderly.

    Science.gov (United States)

    Toyoshima, Kenji; Nakamura, Marie; Adachi, Yusuke; Imaizumi, Akira; Hakamada, Tomomi; Abe, Yasuko; Kaneko, Eiji; Takahashi, Soiciro; Shimokado, Kentaro

    2017-01-01

    Metabolome analyses have shown that plasma amino acid profiles reflect various pathological conditions, such as cancer and diabetes mellitus. It remains unclear, however, whether plasma amino acid profiles change in patients with sarcopenia. This study therefore aimed to investigate whether sarcopenia-specific changes occur in plasma amino acid profiles. A total of 153 community-dwelling and seven institutionalized elderly individuals (56 men, 104 women; mean age, 77.7±7.0 years) were recruited for this cross-sectional analysis. We performed a comprehensive geriatric assessment, which included an evaluation of hand grip strength, gait speed, muscle mass and blood chemistry, including the concentration of 18 amino acids. Twenty-eight of the 160 participants met the criteria for sarcopenia established by the Asian Working Group on Sarcopenia in Older People. Univariate analysis revealed associations between the presence of sarcopenia and a higher plasma concentration of proline and glutamine, lower concentrations of histidine and tryptophan. Multivariable analysis revealed that a higher concentration of proline was the only variable independently associated with sarcopenia. The plasma concentration of proline may be useful for understanding the underlying pathophysiology of sarcopenia.

  19. Increased plasma proline concentrations are associated with sarcopenia in the elderly.

    Directory of Open Access Journals (Sweden)

    Kenji Toyoshima

    Full Text Available Metabolome analyses have shown that plasma amino acid profiles reflect various pathological conditions, such as cancer and diabetes mellitus. It remains unclear, however, whether plasma amino acid profiles change in patients with sarcopenia. This study therefore aimed to investigate whether sarcopenia-specific changes occur in plasma amino acid profiles.A total of 153 community-dwelling and seven institutionalized elderly individuals (56 men, 104 women; mean age, 77.7±7.0 years were recruited for this cross-sectional analysis. We performed a comprehensive geriatric assessment, which included an evaluation of hand grip strength, gait speed, muscle mass and blood chemistry, including the concentration of 18 amino acids.Twenty-eight of the 160 participants met the criteria for sarcopenia established by the Asian Working Group on Sarcopenia in Older People. Univariate analysis revealed associations between the presence of sarcopenia and a higher plasma concentration of proline and glutamine, lower concentrations of histidine and tryptophan. Multivariable analysis revealed that a higher concentration of proline was the only variable independently associated with sarcopenia.The plasma concentration of proline may be useful for understanding the underlying pathophysiology of sarcopenia.

  20. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    -13, and VEGF, LH plasma levels vs. EDTA plasma: IL-2 and IL-4. CONCLUSION: Stored serum, LH plasma, and EDTA plasma from clinical trials can be used for analysis of circulating cytokines and proteins. Variations in measurements occur, but are within reasonable ranges. The optimal type of media...... in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...... on different dates was reasonable. However, samples run on different dates could exhibit different absolute values. The 75th percentile of the fold differences for samples run on different dates was 2.2. No significant difference was found between one and four freeze-thaw cycles (except for HGF...

  1. Altered levels of acetylcholinesterase in Alzheimer plasma.

    Directory of Open Access Journals (Sweden)

    María-Salud García-Ayllón

    Full Text Available BACKGROUND: Many studies have been conducted in an extensive effort to identify alterations in blood cholinesterase levels as a consequence of disease, including the analysis of acetylcholinesterase (AChE in plasma. Conventional assays using selective cholinesterase inhibitors have not been particularly successful as excess amounts of butyrylcholinesterase (BuChE pose a major problem. PRINCIPAL FINDINGS: Here we have estimated the levels of AChE activity in human plasma by first immunoprecipitating BuChE and measuring AChE activity in the immunodepleted plasma. Human plasma AChE activity levels were approximately 20 nmol/min/mL, about 160 times lower than BuChE. The majority of AChE species are the light G(1+G(2 forms and not G(4 tetramers. The levels and pattern of the molecular forms are similar to that observed in individuals with silent BuChE. We have also compared plasma AChE with the enzyme pattern obtained from human liver, red blood cells, cerebrospinal fluid (CSF and brain, by sedimentation analysis, Western blotting and lectin-binding analysis. Finally, a selective increase of AChE activity was detected in plasma from Alzheimer's disease (AD patients compared to age and gender-matched controls. This increase correlates with an increase in the G(1+G(2 forms, the subset of AChE species which are increased in Alzheimer's brain. Western blot analysis demonstrated that a 78 kDa immunoreactive AChE protein band was also increased in Alzheimer's plasma, attributed in part to AChE-T subunits common in brain and CSF. CONCLUSION: Plasma AChE might have potential as an indicator of disease progress and prognosis in AD and warrants further investigation.

  2. 2 D gel based analysis of biological variability of the human plasma proteome

    DEFF Research Database (Denmark)

    Rentsch, Maria Louise; Jessen, Flemming

    individuals and within an individual changes will also happen over time (e.g. after meal intake). Thus, the aim of the present study was to examine the inter-individual variability of plasma protein levels in humans after meal intake. Five subjects consumed three single meals in a randomised order separated...... by one-week interval. Blood samples were drawn before the meal intake and five times during 24 hours for proteome analysis. Plasma was fractionated by use of IgY-12 spin column depleting the 12 highly abundant proteins and further processed for two-dimensional gel electrophoresis. The plasma proteome...

  3. ECR plasma photographs as a plasma diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Racz, R; Biri, S; Palinkas, J [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary)

    2011-04-15

    Low, medium or highly charged ions delivered by electron cyclotron resonance (ECR) ion sources all are produced in the ECR plasma. In order to study such plasmas, high-resolution visible light plasma photographs were taken at the ATOMKI ECR ion source. An 8 megapixel digital camera was used to photograph plasmas made from He, methane, N, O, Ne, Ar, Kr, Xe gases and from their mixtures. The analysis of the photo series gave many qualitative and some valuable physical information on the nature of ECR plasmas. A comparison was made between the plasma photos and computer simulations, and conclusions were drawn regarding the cold electron component of the plasma. The warm electron component of similar simulation was compared with x-ray photos emitted by plasma ions. While the simulations are in good agreement with the photos, a significant difference was found between the spatial distribution of the cold and warm electrons.

  4. Feedback control of plasma configuration in JT-60

    International Nuclear Information System (INIS)

    Ninomiya, Hiromasa; Kikuchi, Mitsuru; Yoshino, Ryuji; Hosogane, Nobuyuki; Kimura, Toyoaki; Kurihara, Kenichi; Takahashi, Minoru; Hayashi, Kazuo.

    1986-08-01

    Plasma current, plasma position (center of the outermost magnetic surface), decay index n index and width of the divertor throat are feedback controlled by using 5 kinds of poloidal field coils in JT-60. 5 control commands are calculated in a feedback control computer in each 1 msec. These feedback control functions are checked in ohmically heated plasma. The control characteristics of the plasma are well understood by the simplified control analysis and are consistent with the precise matrix transfer function analysis in the frequency domain and the simulation analysis which include the effects of eddy currents, delay time elements and mutual interactions between controllers. The usefulness of these analyses is experimentally confirmed. Each controlled variable is well feedback controlled to the command and the experimentally realized equilibrium configuration is checked by the well calibrated magnetic probes. Fast boundary identification code is used for the identification of the equilibrium and results are consistent with the precalculated plasma equilibria. By using this feedback control system of the plasma configuration and the equilibrium identification method, we have obtained the stable limiter and divertor configuration. The maximum parameters obtained during OH(I) experimental period are plasma current I p = 1.8 MA, the effective safety factor q eff e = 5.7 x 10 19 m -3 (Murakami parameter of 4.5) and the pulse length of 5 ∼ 10 sec. (author)

  5. Inertia effects on the rigid displacement approximation of tokamak plasma vertical motion

    International Nuclear Information System (INIS)

    Carrera, R.; Khayrutdinov, R.R.; Azizov, E.A.; Montalvo, E.; Dong, J.Q.

    1991-01-01

    Elongated plasmas in tokamaks are unstable to axisymmetric vertical displacements. The vacuum vessel and passive conductors can stabilize the plasma motion in the short time scale. For stabilization of the plasma movement in the long time scale an active feedback control system is required. A widely used method of plasma stability analysis uses the Rigid Displacement Model (RDM) of plasma behavior. In the RDM it is assumed that the plasma displacement is small and usually plasma inertia effects are neglected. In addition, it is considered that no changes in plasma shape, plasma current, and plasma current profile take place throughout the plasma motion. It has been demonstrated that the massless-filament approximation (instantaneous force-balance) accurately reproduces the unstable root of the passive stabilization problem. Then, on the basis that the instantaneous force-balance approximation is correct in the passive stabilization analysis, the massless approximation is utilized also in the study of the plasma vertical stabilization by active feedback. The authors show here that the RDM (without mass effects included) does not provide correct stability results for a tokamak configuration (plasma column, passive conductors, and feedback control coils). Therefore, it is concluded that inertia effects have to be retained in the RDM system of equations. It is shown analytically and numerically that stability diagrams with and without plasma-mass corrections differ significantly. When inertia effects are included, the stability region is more restricted than obtained in the massless approximation

  6. Steady state behavior of rotating plasmas in a vacuum-arc centrifuge

    International Nuclear Information System (INIS)

    Bittencourt, J.A.; Ludwig, G.O.

    1987-01-01

    The steady state behaviour of the fully ionized, multiple species, rotating, magnetized plasma in a vacuum-arc plasma centrifuge is described in detail. The analysis is based on a multiple species fluid model which includes electromagnetic, pressure gradient, centrifugal and collisional forces, for each species, in cylindrical geometry. It is shown that there is a family of theoretically possible dynamical equilibrium configurations, which can be achieved by different combinations of ion rotation velocity, radial ion density distribution and radial dependence of internal electric potential. The parametric dependences of the various plasma parameters under equilibrium conditions, including the ion separation factor, are presented for a nickel-copper plasma. The numerical results are analysed and discussed in light of experimentally measured plasma characteristics in a vacuum-arc plasma centrifuge. (author)

  7. Steady state behavior of rotating plasmas in a vacuum-arc centrifuge

    International Nuclear Information System (INIS)

    Bittencourt, J.A.; Ludwig, G.O.

    1986-06-01

    The steady state behavior of the fully ionized, multiple species, rotating, magnetized plasma in a vacuum-arc plasma centrifuge is described in detail. The analysis is based on a multiple species fluid model which includes electromagnetic, pressure gradient, centrifugal and collisional forces, for each species, in cylindrical geometry. It is showm that there is a family of theoretically possible dynamical equilibrium configurations, which can be achieved by different combinations of ion rotation velocity, radial ion density distribution and radial dependence of internal electric potential. The parametric dependences of the various plasma parameters under equilibrium conditions, including the ion separation factor, are presented for a nickel-copper plasma. The numerical results are analysed and discussed on light of experimentally measured plasma characteristics in a vacuum-arc plasma centrifuge. (Author) [pt

  8. Rapid analysis of pharmaceuticals and personal care products in fish plasma micro-aliquots using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chen, Fangfang; Gong, Zhiyuan; Kelly, Barry C

    2015-02-27

    A sensitive analytical method based on liquid-liquid extraction (LLE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed for rapid analysis of 11 pharmaceuticals and personal care products (PPCPs) in fish plasma micro-aliquots (∼20μL). Target PPCPs included, bisphenol A, carbamazepine, diclofenac, fluoxetine, gemfibrozil, ibuprofen, naproxen, risperidone, sertraline, simvastatin and triclosan. A relatively quicker and cheaper LLE procedure exhibited comparable analyte recoveries with solid-phase extraction. Rapid separation and analysis of target compounds in fish plasma extracts was achieved by employing a high efficiency C-18 HPLC column (Agilent Poroshell 120 SB-C18, 2.1mm×50mm, 2.7μm) and fast polarity switching, enabling effective monitoring of positive and negative ions in a single 9min run. With the exception of bisphenol A, which exhibited relatively high background contamination, method detection limits of individual PPCPs ranged between 0.15 and 0.69pg/μL, while method quantification limits were between 0.05 and 2.3pg/μL. Mean matrix effect (ME) values ranged between 65 and 156% for the various target analytes. Isotope dilution quantification using isotopically labelled internal surrogates was utilized to correct for signal suppression or enhancement and analyte losses during sample preparation. The method was evaluated by analysis of 20μL plasma micro-aliquots collected from zebrafish (Danio rerio) from a laboratory bioaccumulation study, which included control group fish (no exposure), as well as fish exposed to environmentally relevant concentrations of PPCPs. Using the developed LC-MS/MS based method, concentrations of the studied PPCPs were consistently detected in the low pg/μL (ppb) range. The method may be useful for investigations requiring fast, reliable concentration measurements of PPCPs in fish plasma. In particular, the method may be applicable for in situ contaminant biomonitoring, as well as

  9. Plasmas and fluids

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Plasma and fluid physics includes the fields of fusion research and space investigation. This book discusses the most important advances in these areas over the past decade and recommends a stronger commitment to basic research in plasma and fluid physics. The book recommends that plasma and fluid physics be included in physics curriculums because of their increasing importance in energy and defense. The book also lists recent accomplishments in the fields of general plasma physics, fusion plasma confinement and heating, space and astrophysical plasmas, and fluid physics and lists research opportunities in these areas. A funding summary explains how research monies are allocated and suggests ways to improve their effectiveness

  10. Protein precipitation: an expedient procedure for the routine analysis of the plasma metabolites of [123I]IBZM

    International Nuclear Information System (INIS)

    Zea-Ponce, Yolanda; Laruelle, Marc

    1999-01-01

    Plasma metabolite analysis of the single photon emission computed tomography (SPECT) D 2 /D 3 receptor radiotracer (S)(-)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-2-hydroxy-3-[ 123 I] iodo-6-methoxyb enzamide ([ 123 I]IBZM) is needed for the equilibrium analysis of the SPECT data, in brain imaging studies involving bolus plus constant infusion paradigm. The purpose of these experiments was to find an appropriate procedure to expedite this analysis during routine determinations. The procedure was applied to the plasma analysis of 22 human subjects. Each plasma sample was subjected to acetonitrile protein precipitation. After separation of the pellet, the acetonitrile fraction contained 91%±2% (n=88) of the mixture of labeled metabolites and parent compound. The recovery coefficient of unmetabolized [ 123 I]IBZM determined with an standard plasma sample was 95%±2% (n=22). The percent parent compound present in the extracted fraction, measured by high performance liquid chromatography, was 16%±9% (n=85) and the percent metabolites was 84%±9% (n=85). Free fraction determination (f 1 , fraction of radiotracer unbound to protein), was 4%±0.8% (n=22). Free fraction of parent was 15%±8% (n=85). The results indicate that acetonitrile protein precipitation is an adequate method for the analysis of the [ 123 I]IBZM plasma metabolites

  11. Theory of electromagnetic fluctuations for magnetized multi-species plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Roberto E., E-mail: roberto.navarro@ug.uchile.cl; Muñoz, Víctor [Departamento de Física, Facultad de Ciencias, Universidad de Chile, Casilla 653, Santiago (Chile); Araneda, Jaime [Departamento de Física, Universidad de Concepción, Concepción 4070386 (Chile); Moya, Pablo S. [NASA Goddard Space Flight Center, Heliophysics Science Division, Geospace Physics Laboratory, Mail Code 673, Greenbelt, Maryland 20771 (United States); Department of Physics, Catholic University of America, Washington, D. C. 20064 (United States); Viñas, Adolfo F. [NASA Goddard Space Flight Center, Heliophysics Science Division, Geospace Physics Laboratory, Mail Code 673, Greenbelt, Maryland 20771 (United States); Valdivia, Juan A. [Departamento de Física, Facultad de Ciencias, Universidad de Chile, Casilla 653, Santiago (Chile); Centro de Estudios Interdisciplinarios Básicos y Aplicados en Complejidad, CEIBA complejidad, Bogotá (Colombia)

    2014-09-15

    Analysis of electromagnetic fluctuations in plasma provides relevant information about the plasma state and its macroscopic properties. In particular, the solar wind persistently sustains a small but detectable level of magnetic fluctuation power even near thermal equilibrium. These fluctuations may be related to spontaneous electromagnetic fluctuations arising from the discreteness of charged particles. Here, we derive general expressions for the plasma fluctuations in a multi-species plasma following arbitrary distribution functions. This formalism, which generalizes and includes previous works on the subject, is then applied to the generation of electromagnetic fluctuations propagating along a background magnetic field in a plasma of two proton populations described by drifting bi-Maxwellians.

  12. Microscopic analysis of nanostructured plasma coatings

    Science.gov (United States)

    Ageev, E. V.; Altukhov, A. Yu; Ageeva, E. V.; Khardikov, S. V.

    2018-03-01

    In the course of the study, it was found that plasma nanocomposite coating obtained from a mixture of powders of BRS, VK8 and nichrome with a portable plasma device “ALPES-02M” has high performance properties, which significantly expands the scope of its application.

  13. Plasma nutrient status of patients with Alzheimer's disease: Systematic review and meta-analysis.

    Science.gov (United States)

    Lopes da Silva, Sofia; Vellas, Bruno; Elemans, Saskia; Luchsinger, José; Kamphuis, Patrick; Yaffe, Kristine; Sijben, John; Groenendijk, Martine; Stijnen, Theo

    2014-07-01

    Alzheimer disease (AD) patients are at risk of nutritional insufficiencies because of physiological and psychological factors. Nutritional compounds are postulated to play a role in the pathophysiological processes that are affected in AD. We here provide the first systematic review and meta-analysis that compares plasma levels of micronutrients and fatty acids in AD patients to those in cognitively intact elderly controls. A secondary objective was to explore the presence of different plasma nutrient levels between AD and control populations that did not differ in measures of protein/energy nourishment. We screened literature published after 1990 in the Cochrane Central Register of Controlled Trials, Medline, and Embase electronic databases using Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines for AD patients, controls, micronutrient, vitamins, and fatty acids, resulting in 3397 publications, of which 80 met all inclusion criteria. Status of protein/energy malnutrition was assessed by body mass index, mini nutritional assessment score, or plasma albumin. Meta-analysis, with correction for differences in mean age between AD patients and controls, was performed when more than five publications were retrieved for a specific nutrient. We identified five or more studies for folate, vitamin A, vitamin B12, vitamin C, vitamin D, vitamin E, copper, iron, and zinc but fewer than five studies for vitamins B1 and B6, long-chain omega-3 fatty acids, calcium, magnesium, manganese, and selenium (the results of the individual publications are discussed). Meta-analysis showed significantly lower plasma levels of folate and vitamin A, vitamin B12, vitamin C, and vitamin E (P vitamin D (P = .075) were found in AD patients. No significant differences were observed for plasma levels of copper and iron. A meta-analysis that was limited to studies reporting no differences in protein/energy malnourishment between AD and control populations yielded

  14. Evaluation of mechanism of cold atmospheric pressure plasma assisted polymerization of acrylic acid on low density polyethylene (LDPE) film surfaces: Influence of various gaseous plasma pretreatment

    Science.gov (United States)

    Ramkumar, M. C.; Pandiyaraj, K. Navaneetha; Arun Kumar, A.; Padmanabhan, P. V. A.; Uday Kumar, S.; Gopinath, P.; Bendavid, A.; Cools, P.; De Geyter, N.; Morent, R.; Deshmukh, R. R.

    2018-05-01

    Owing to its exceptional physiochemical properties, low density poly ethylene (LDPE) has wide range of tissue engineering applications. Conversely, its inadequate surface properties make LDPE an ineffectual candidate for cell compatible applications. Consequently, plasma-assisted polymerization with a selected precursor is a good choice for enhancing its biocompatibility. The present investigation studies the efficiency of plasma polymerization of acrylic acid (AAC) on various gaseous plasma pretreated LDPE films by cold atmospheric pressure plasma, to enhance its cytocompatibility. The change in chemical composition and surface topography of various gaseous plasma pretreated and acrylic deposited LDPE films has been assessed by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The changes in hydrophilic nature of surface modified LDPE films were studied by contact angle (CA) analysis. Cytocompatibility of the AAC/LDPE films was also studied in vitro, using RIN-5F cells. The results acquired by the XPS and AFM analysis clearly proved that cold atmospheric pressure (CAP) plasma assisted polymerization of AAC enhances various surface properties including carboxylic acid functional group density and increased surface roughness on various gaseous plasma treated AAC/LDPE film surfaces. Moreover, contact angle analysis clearly showed that the plasma polymerized samples were hydrophilic in nature. In vitro cytocompatibility analysis undoubtedly validates that the AAC polymerized various plasma pretreated LDPE films surfaces stimulate cell distribution and proliferation compared to pristine LDPE films. Similarly, cytotoxicity analysis indicates that the AAC deposited various gaseous plasma pretreated LDPE film can be considered as non-toxic as well as stimulating cell viability significantly. The cytocompatible properties of AAC polymerized Ar + O2 plasma pretreated LDPE films were found to be more pronounced compared to the other plasma pretreated

  15. Physiological adaptation of maternal plasma volume during pregnancy: a systematic review and meta-analysis.

    Science.gov (United States)

    de Haas, S; Ghossein-Doha, C; van Kuijk, S M J; van Drongelen, J; Spaanderman, M E A

    2017-02-01

    To describe the physiological pattern of gestational plasma volume adjustments in normal singleton pregnancy and compare this with the pattern in pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction. We performed a meta-analysis of the current literature on plasma volume adjustments during physiological and complicated pregnancies. Literature was retrieved from PubMed (NCBI) and EMBASE (Ovid) databases. Included studies reported both reference plasma volume measurements (non-pregnant, prepregnancy or postpartum) and measurements obtained during predetermined gestational ages. Mean differences bet ween the reference and pregnancy plasma volume measurements were calculated for predefined intervals of gestational age using a random-effects model described by DerSimonian and Laird. Thirty studies were included in the meta-analysis with publication dates ranging from 1934 to 2007. Plasma volume increased in the first weeks of pregnancy, with the steepest increase occurring during the second trimester. Plasma volume continued to increase in the third trimester with a pooled maximum increase of 1.13 L (95% CI, 1.07-1.19 L), an increase of 45.6% (95% CI, 43.0-48.1%) in physiological pregnancies compared with the reference value. The plasma volume expansion in gestational hypertensive and growth-restricted pregnancies was 0.80 L (95% CI, 0.59-1.02 L), an increase of 32.3% (95% CI, 23.6-41.1%) in the third trimester, a smaller increase than in physiological pregnancies (P embarazo: una revisi\\xF3n sistemática y metaanálisis RESUMEN OBJETIVO: Describir el patrón fisiológico de los cambios en el volumen del plasma gestacional en embarazos normales con feto único y compararlo con el patrón en los embarazos complicados por hipertensión gestacional, preeclampsia o restricción del crecimiento fetal. MÉTODOS: Se realizó un metaanálisis de la literatura actual sobre los cambios en el volumen de plasma durante

  16. Influence of plasma background including neutrals on scrape-off layer filaments using 3D simulations

    Directory of Open Access Journals (Sweden)

    D. Schwörer

    2017-08-01

    Full Text Available This paper investigates the effect of the plasma background, including neutrals in a self-consistent way, on filaments in the scrape-off layer (SOL of fusion devices. A strong dependency of filament motion on background density and temperature is observed. The radial filament motion shows an increase in velocity with decreasing background density and increasing background temperature. In the simulations presented here, three neutral-filament interaction models have been compared, one with a static neutral background, one with no interaction between filaments and neutrals, and one co-evolving the neutrals self consistently with the filaments. With the background conditions employed here, which do not show detachment, there are no significant effects of neutrals on filaments, as by the time the filament reaches maximum velocity, the neutral density has not changed significantly.

  17. Elements of plasma technology

    CERN Document Server

    Wong, Chiow San

    2016-01-01

    This book presents some fundamental aspects of plasma technology that are important for beginners interested to start research in the area of plasma technology . These include the properties of plasma, methods of plasma generation and basic plasma diagnostic techniques. It also discusses several low cost plasma devices, including pulsed plasma sources such as plasma focus, pulsed capillary discharge, vacuum spark and exploding wire; as well as low temperature plasmas such as glow discharge and dielectric barrier discharge which the authors believe may have potential applications in industry. The treatments are experimental rather than theoretical, although some theoretical background is provided where appropriate. The principles of operation of these devices are also reviewed and discussed.

  18. Magnetic analysis of tokamak plasma with approximate MHD equilibrium solution

    International Nuclear Information System (INIS)

    Moriyama, Shin-ichi; Hiraki, Naoji

    1993-01-01

    A magnetic analysis method for determining equilibrium configuration parameters (plasma shape, poloidal beta and internal inductance) on a non-circular tokamak is described. The feature is to utilize an approximate MHD equilibrium solution which explicitly relates the configuration parameters with the magnetic fields picked up by magnetic sensors. So this method is suitable for the real-time analysis performed during a tokamak discharge. A least-squares fitting procedure is added to the analytical algorithm in order to reduce the errors in the magnetic analysis. The validity is investigated through the numerical calculation for a tokamak equilibrium model. (author)

  19. Plasma-safety assessment model and safety analyses of ITER

    International Nuclear Information System (INIS)

    Honda, T.; Okazaki, T.; Bartels, H.-H.; Uckan, N.A.; Sugihara, M.; Seki, Y.

    2001-01-01

    A plasma-safety assessment model has been provided on the basis of the plasma physics database of the International Thermonuclear Experimental Reactor (ITER) to analyze events including plasma behavior. The model was implemented in a safety analysis code (SAFALY), which consists of a 0-D dynamic plasma model and a 1-D thermal behavior model of the in-vessel components. Unusual plasma events of ITER, e.g., overfueling, were calculated using the code and plasma burning is found to be self-bounded by operation limits or passively shut down due to impurity ingress from overheated divertor targets. Sudden transition of divertor plasma might lead to failure of the divertor target because of a sharp increase of the heat flux. However, the effects of the aggravating failure can be safely handled by the confinement boundaries. (author)

  20. Atmospheric-pressure plasma technology

    International Nuclear Information System (INIS)

    Kogelschatz, U

    2004-01-01

    Major industrial plasma processes operating close to atmospheric pressure are discussed. Applications of thermal plasmas include electric arc furnaces and plasma torches for generation of powders, for spraying refractory materials, for cutting and welding and for destruction of hazardous waste. Other applications include miniature circuit breakers and electrical discharge machining. Non-equilibrium cold plasmas at atmospheric pressure are obtained in corona discharges used in electrostatic precipitators and in dielectric-barrier discharges used for generation of ozone, for pollution control and for surface treatment. More recent applications include UV excimer lamps, mercury-free fluorescent lamps and flat plasma displays

  1. Initial operation of NSTX with plasma control

    International Nuclear Information System (INIS)

    Gates, D.; Bell, M.; Ferron, J.; Kaye, S.; Menard, J.; Mueller, D.; Neumeyer, C.; Sabbagh, S.

    2000-01-01

    First plasma, with a maximum current of 300kA, was achieved on NSTX in February 1999. These results were obtained using preprogrammed coil currents. The first controlled plasmas on NSTX were made starting in August 1999 with the full 1MA plasma current achieved in December 1999. The controlled quantities were plasma position (R, Z) and current (Ip). Variations in the plasma shape are achieved by adding preprogrammed currents to those determined by the control parameters. The control system is fully digital, with plasma position and current control, data acquisition, and power supply control all occurring in the same four-processor real time computer. The system uses the PCS (Plasma Control Software) system designed at General Atomics. Modular control algorithms, specific to NSTX, were written and incorporated into the PCS. The application algorithms do the actual control calculations, with the PCS handling data passing. The control system, including planned upgrades, will be described, along with results of the initial controlled plasma operations. Analysis of the performance of the control system will also be presented

  2. Lipidomics reveals a remarkable diversity of lipids in human plasma.

    Science.gov (United States)

    Quehenberger, Oswald; Armando, Aaron M; Brown, Alex H; Milne, Stephen B; Myers, David S; Merrill, Alfred H; Bandyopadhyay, Sibali; Jones, Kristin N; Kelly, Samuel; Shaner, Rebecca L; Sullards, Cameron M; Wang, Elaine; Murphy, Robert C; Barkley, Robert M; Leiker, Thomas J; Raetz, Christian R H; Guan, Ziqiang; Laird, Gregory M; Six, David A; Russell, David W; McDonald, Jeffrey G; Subramaniam, Shankar; Fahy, Eoin; Dennis, Edward A

    2010-11-01

    The focus of the present study was to define the human plasma lipidome and to establish novel analytical methodologies to quantify the large spectrum of plasma lipids. Partial lipid analysis is now a regular part of every patient's blood test and physicians readily and regularly prescribe drugs that alter the levels of major plasma lipids such as cholesterol and triglycerides. Plasma contains many thousands of distinct lipid molecular species that fall into six main categories including fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, and prenols. The physiological contributions of these diverse lipids and how their levels change in response to therapy remain largely unknown. As a first step toward answering these questions, we provide herein an in-depth lipidomics analysis of a pooled human plasma obtained from healthy individuals after overnight fasting and with a gender balance and an ethnic distribution that is representative of the US population. In total, we quantitatively assessed the levels of over 500 distinct molecular species distributed among the main lipid categories. As more information is obtained regarding the roles of individual lipids in health and disease, it seems likely that future blood tests will include an ever increasing number of these lipid molecules.

  3. Plasma sheath in non-Maxwellian plasma

    International Nuclear Information System (INIS)

    Shimizu, Takuo; Horigome, Takashi

    1992-01-01

    Reviewing many theoretical and experimental works on the electron-energy distributions (EEDF) of various plasmas, we point out that many plasmas have EEDF of non-Maxwellian in shape. Therefore, the recent treatment of plasma sheath using the Maxwell-Boltzmann distribution approximation should be improved. To do this, we have adopted Rutcher's standard distribution as a generalized form in place of the traditional Maxwellian, and found that the minimum energy of ions entering the sheath edge (Bohm's criterion) varies largely, and have also shown the variation of Debye length with the shape of EEDF. The length is the most important parameter to proceed with more detailed analysis on plasma-sheaths, and also to control them in the future. (author)

  4. Analysis of the plasma sweeper

    International Nuclear Information System (INIS)

    Glanz, J.; Motley, R.W.

    1982-09-01

    The coupling of lower hybrid waves to a plasma can be modified by placing potentials on electrodes near the mouth of a phased array. Positive potentials on the electrodes create an electric field that sweeps the plasma away at a velocity c anti E x anti B/B 2 . In this paper we derive the electric field created by the applied potential from the nondivergent character of the current flow and the ion momentum equation, in which ion-neutral charge-exchange collisions are retained, and we compare the predictions with experimental data

  5. Reduced, three-dimensional, nonlinear equations for high-β plasmas including toroidal effects

    International Nuclear Information System (INIS)

    Schmalz, R.

    1980-11-01

    The resistive MHD equations for toroidal plasma configurations are reduced by expanding to the second order in epsilon, the inverse aspect ratio, allowing for high β = μsub(o)p/B 2 of order epsilon. The result is a closed system of nonlinear, three-dimensional equations where the fast magnetohydrodynamic time scale is eliminated. In particular, the equation for the toroidal velocity remains decoupled. (orig.)

  6. Simulating the influence of plasma protein on measured receptor affinity in biochemical assays reveals the utility of Schild analysis for estimating compound affinity for plasma proteins.

    Science.gov (United States)

    Blakeley, D; Sykes, D A; Ensor, P; Bertran, E; Aston, P J; Charlton, S J

    2015-11-01

    Plasma protein binding (PPB) influences the free fraction of drug available to bind to its target and is therefore an important consideration in drug discovery. While traditional methods for assessing PPB (e.g. rapid equilibrium dialysis) are suitable for comparing compounds with relatively weak PPB, they are not able to accurately discriminate between highly bound compounds (typically >99.5%). The aim of the present work was to use mathematical modelling to explore the potential utility of receptor binding and cellular functional assays to estimate the affinity of compounds for plasma proteins. Plasma proteins are routinely added to in vitro assays, so a secondary goal was to investigate the effect of plasma proteins on observed ligand-receptor interactions. Using the principle of conservation of mass and the law of mass action, a cubic equation was derived describing the ligand-receptor complex [LR] in the presence of plasma protein at equilibrium. The model demonstrates the profound influence of PPB on in vitro assays and identifies the utility of Schild analysis, which is usually applied to determine receptor-antagonist affinities, for calculating affinity at plasma proteins (termed KP ). We have also extended this analysis to functional effects using operational modelling and demonstrate that these approaches can also be applied to cell-based assay systems. These mathematical models can potentially be used in conjunction with experimental data to estimate drug-plasma protein affinities in the earliest phases of drug discovery programmes. © 2015 The British Pharmacological Society.

  7. Shock Wave Dynamics in Weakly Ionized Plasmas

    Science.gov (United States)

    Johnson, Joseph A., III

    1999-01-01

    An investigation of the dynamics of shock waves in weakly ionized argon plasmas has been performed using a pressure ruptured shock tube. The velocity of the shock is observed to increase when the shock traverses the plasma. The observed increases cannot be accounted for by thermal effects alone. Possible mechanisms that could explain the anomalous behavior include a vibrational/translational relaxation in the nonequilibrium plasma, electron diffusion across the shock front resulting from high electron mobility, and the propagation of ion-acoustic waves generated at the shock front. Using a turbulence model based on reduced kinetic theory, analysis of the observed results suggest a role for turbulence in anomalous shock dynamics in weakly ionized media and plasma-induced hypersonic drag reduction.

  8. Shotgun proteomics of plant plasma membrane and microdomain proteins using nano-LC-MS/MS.

    Science.gov (United States)

    Takahashi, Daisuke; Li, Bin; Nakayama, Takato; Kawamura, Yukio; Uemura, Matsuo

    2014-01-01

    Shotgun proteomics allows the comprehensive analysis of proteins extracted from plant cells, subcellular organelles, and membranes. Previously, two-dimensional gel electrophoresis-based proteomics was used for mass spectrometric analysis of plasma membrane proteins. In order to get comprehensive proteome profiles of the plasma membrane including highly hydrophobic proteins with a number of transmembrane domains, a mass spectrometry-based shotgun proteomics method using nano-LC-MS/MS for proteins from the plasma membrane proteins and plasma membrane microdomain fraction is described. The results obtained are easily applicable to label-free protein semiquantification.

  9. Analysis of the functional aspects and seminal plasma proteomic profile of sperm from smokers.

    Science.gov (United States)

    Antoniassi, Mariana Pereira; Intasqui, Paula; Camargo, Mariana; Zylbersztejn, Daniel Suslik; Carvalho, Valdemir Melechco; Cardozo, Karina H M; Bertolla, Ricardo Pimenta

    2016-11-01

    To evaluate the effect of smoking on sperm functional quality and seminal plasma proteomic profile. Sperm functional tests were performed in 20 non-smoking men with normal semen quality, according to the World Health Organization (2010) and in 20 smoking patients. These included: evaluation of DNA fragmentation by alkaline Comet assay; analysis of mitochondrial activity using DAB staining; and acrosomal integrity evaluation by PNA binding. The remaining semen was centrifuged and seminal plasma was used for proteomic analysis (liquid chromatography-tandem mass spectrometry). The quantified proteins were used for Venn diagram construction in Cytoscape 3.2.1 software, using the PINA4MS plug-in. Then, differentially expressed proteins were used for functional enrichment analysis of Gene Ontology categories, Kyoto Encyclopedia of Genes and Genomes and Reactome, using Cytoscape software and the ClueGO 2.2.0 plug-in. Smokers had a higher percentage of sperm DNA damage (Comet classes III and IV; P analysis, 422 proteins were identified and quantified, of which one protein was absent, 27 proteins were under-represented and six proteins were over-represented in smokers. Functional enrichment analysis showed the enrichment of antigen processing and presentation, positive regulation of prostaglandin secretion involved in immune response, protein kinase A signalling and arachidonic acid secretion, complement activation, regulation of the cytokine-mediated signalling pathway and regulation of acute inflammatory response in the study group (smokers). In conclusion, cigarette smoking was associated with an inflammatory state in the accessory glands and in the testis, as shown by enriched proteomic pathways. This state causes an alteration in sperm functional quality, which is characterized by decreased acrosome integrity and mitochondrial activity, as well as by increased nuclear DNA fragmentation. © 2016 The Authors BJU International © 2016 BJU International Published by John

  10. Parametric analysis of a magnetized cylindrical plasma

    International Nuclear Information System (INIS)

    Ahedo, Eduardo

    2009-01-01

    The relevant macroscopic model, the spatial structure, and the parametric regimes of a low-pressure plasma confined by a cylinder and an axial magnetic field is discussed for the small-Debye length limit, making use of asymptotic techniques. The plasma response is fully characterized by three-dimensionless parameters, related to the electron gyroradius, and the electron and ion collision mean-free-paths. There are the unmagnetized regime, the main magnetized regime, and, for a low electron-collisionality plasma, an intermediate-magnetization regime. In the magnetized regimes, electron azimuthal inertia is shown to be a dominant phenomenon in part of the quasineutral plasma region and to set up before ion radial inertia. In the main magnetized regime, the plasma structure consists of a bulk diffusive region, a thin layer governed by electron inertia, a thinner sublayer controlled by ion inertia, and the non-neutral Debye sheath. The solution of the main inertial layer yields that the electron azimuthal energy near the wall is larger than the electron thermal energy, making electron resistivity effects non-negligible. The electron Boltzmann relation is satisfied only in the very vicinity of the Debye sheath edge. Ion collisionality effects are irrelevant in the magnetized regime. Simple scaling laws for plasma production and particle and energy fluxes to the wall are derived.

  11. Double plasma system with inductively coupled source plasma and quasi-quiescent target plasma

    International Nuclear Information System (INIS)

    Massi, M.; Maciel, H.S.

    1995-01-01

    Cold plasmas have successfully been used in the plasma-assisted material processing industry. An understanding of the physicochemical mechanisms involved in the plasma-surface interaction is needed for a proper description of deposition and etching processes at material surfaces. Since these mechanisms are dependent on the plasma properties, the development of diagnostic techniques is strongly desirable for determination of the plasma parameters as well as the characterization of the electromagnetic behaviour of the discharge. In this work a dual discharge chamber, was specially designed to study the deposition of thin films via plasma polymerization process. In the Pyrex chamber an inductively coupled plasma can be excited either in the diffuse low density E-mode or in the high density H-mode. This plasma diffuses into the cylindrical stainless steel chamber which is covered with permanent magnets to produce a multidipole magnetic field configuration at the surface. By that means a double plasma is established consisting of a RF source plasma coupled to a quasi-quiescent target plasma. The preliminary results presented here refer to measurements of the profiles of plasma parameters along the central axis of the double plasma apparatus. Additionally a spectrum analysis performed by means of a Rogowski coil probe immersed into the source plasma is also presented. The discharge is made in argon with pressure varying from 10 -2 to 1 torr, and the rf from 10 to 150 W

  12. Plasma cytokines in acute stroke

    DEFF Research Database (Denmark)

    Christensen, Hanne Krarup; Boysen, Gudrun; Christensen, Erik

    2011-01-01

    GOALS: The aim of this study was to test the relations between plasma cytokines and the clinical characteristics, course, and risk factors in acute stroke. PATIENTS AND METHODS: The analysis was based on 179 patients with acute stroke included within 24 hours of stroke onset. On inclusion and 3...... months later plasma levels of interleukin 1 beta (IL-1beta), tumor necrosis factor alpha (TNF-alpha), interleukin-1 receptor antagonist (IL-1RA), interleukin 6 (IL-6), interleukin 10 (IL-10), soluble tumor necrosis factor receptor 1 (sTNF-R1), and soluble tumor necrosis factor receptor 2 (sTNF-R2) were...

  13. Trade studies of plasma elongation for next-step tokamaks

    International Nuclear Information System (INIS)

    Galambos, J.D.; Strickler, D.J.; Peng, Y.K.M.; Reid, R.L.

    1988-09-01

    The effect of elongation on minimum-cost devices is investigated for elongations ranging from 2 to 3. The analysis, carried out with the TETRA tokamak systems code, includes the effects of elongation on both physics (plasma beta limit) and engineering (poloidal field coil currents) issues. When ignition is required, the minimum cost occurs for elongations from 2.3 to 2.9, depending on the plasma energy confinement scaling used. Scalings that include favorable plasma current dependence and/or degradation with fusion power tend to have minimum cost at higher elongation (2.5-2.9); scalings that depend primarily on size result in lower elongation (/approximately/2.3) for minimum cost. For design concepts that include steady-state current-driven operation, minimum cost occurs at an elongation of 2.3. 12 refs., 13 figs

  14. Quantitative analysis of the experimental cytotoxic drug cyclopentenyl cytosine and its metabolite in plasma with HPLC tandem mass spectrometry

    NARCIS (Netherlands)

    Schimmel, Kirsten; van Lenthe, Henk; Leen, Rene; Kulik, Willem; Verschuur, Arnauld; Guchelaar, Henk-Jan; van Kuilenburg, André

    2008-01-01

    The cytotoxic drug cyclopentenyl cytosine (CPEC) is currently being investigated in early clinical trials. Monitoring of plasma levels is required for pharmacokinetic analysis and management of toxicity. This paper describes the analysis of CPEC and cyclopentenyl uracil (CPEU) in plasma by

  15. An isotopic analysis process with optical emission spectrometry on a laser-produced plasma

    International Nuclear Information System (INIS)

    Mauchien, P.; Pietsch, W.; Petit, A.; Briand, A.

    1994-01-01

    The sample that is to be analyzed is irradiated with a laser beam to produce a plasma at the sample surface; the spectrum of the light emitted by the plasma is analyzed and the isotope composition of the sample is derived from the spectrometry. The process is preferentially applied to uranium and plutonium; it is rapid, simpler and cheaper than previous methods, and may be applied to 'in-situ' isotopic analysis in nuclear industry. 2 figs

  16. Properties of the plasma of the scrape-off layer including the effects of polarization drift

    International Nuclear Information System (INIS)

    Petrov, V.G.

    1987-01-01

    The plasma of the scrape-off layer of a tokamak is analyzed. The toroidal electric drift and the polarization drift of the charged particles are taken into account. The buildup of electric charge in the shadow of the poloidal limiter which results from toroidal drift is offset by a current to the limiter. The radial electric current associated with the polarization drift of ions is important near the inner boundary of the scrape-off layer. The distributions of the electric potential and the plasma density in the scrape-off layer are derived

  17. Analysis of the accident with the coolant discharge into the plasma vessel of the W7-X fusion experimental facility

    Energy Technology Data Exchange (ETDEWEB)

    Ušpuras, E.; Kaliatka, A.; Kaliatka, T., E-mail: tadas@mail.lei.lt

    2013-06-15

    Highlights: • The accident with water ingress into the plasma vessel in Wendelstein nuclear fusion device W7-X was analyzed. • The analysis of the processes in the plasma vessel and ventilation system was performed using thermal-hydraulic RELAP5 Mod3.3 code. • The suitability of pressure increase prevention system was assessed. • All analyses results will be used for the optimization of W7-X design and to ensure safe operation of this nuclear fusion device. -- Abstract: Fusion is the energy production technology, which could potentially solve problems with growing energy demand of population in the future. Starting 2007, Lithuanian Energy Institute (LEI) is a member of European Fusion Development Agreement (EFDA) organization. LEI is cooperating with Max Planck Institute for Plasma Physics (IPP, Germany) in the frames of EFDA project by performing safety analysis of fusion device W7-X. Wendelstein 7-X (W7-X) is an experimental stellarator facility currently being built in Greifswald, Germany, which shall demonstrate that in the future energy could be produced in such type of fusion reactors. In this paper the safety analysis of 40 mm inner diameter coolant pipe rupture in cooling circuit and discharge of steam–water mixture through the leak into plasma vessel during the W7-X no-plasma “baking” operation mode is presented. For the analysis the model of W7-X cooling system (pumps, valves, pipes, hydro-accumulators, and heat exchangers) and plasma vessel was developed by employing system thermal-hydraulic state-of-the-art RELAP5 Mod3.3 code. This paper demonstrated that the developed RELAP5 model enables to analyze the processes in divertor cooling system and plasma vessel. The results of analysis demonstrated that the proposed burst disc, connecting the plasma vessel with venting system, opens and pressure inside plasma vessel does not exceed the limiting 1.1 × 10{sup 5} Pa absolute pressure. Thus, the plasma vessel remains intact after loss

  18. The Effect of Plasma Surface Treatment on a Porous Green Ceramic Film with Polymeric Binder Materials

    International Nuclear Information System (INIS)

    Yun Jeong Woo

    2013-01-01

    To reduce time and energy during thermal binder removal in the ceramic process, plasma surface treatment was applied before the lamination process. The adhesion strength in the lamination films was enhanced by oxidative plasma treatment of the porous green ceramic film with polymeric binding materials. The oxygen plasma characteristics were investigated through experimental parameters and weight loss analysis. The experimental results revealed the need for parameter analysis, including gas material, process time, flow rate, and discharge power, and supported a mechanism consisting of competing ablation and deposition processes. The weight loss analysis was conducted for cyclic plasma treatment rather than continuous plasma treatment for the purpose of improving the film's permeability by suppressing deposition of the ablated species. The cyclic plasma treatment improved the permeability compared to the continuous plasma treatment.

  19. Mass and energy analysis of the ions in a plasma flood system

    International Nuclear Information System (INIS)

    Wooding, A.C.; Armour, D.G.; Berg, J.A. van den; Holmes, A.J.T.; Burgess, C.; Goldberg, R.D.

    2005-01-01

    Plasma flood systems, capable of providing a copious supply of electrons are used in ion implanters to control wafer charging and provide effective space charge neutralisation of the ion beam in the post-analysis/post-deceleration section of the beamline. Under appropriate conditions the plasma from the flood system interacts with the ion beam and this bridging leads to an enhanced beam transport efficiency in the final critical stage of the beamline. The effectiveness of this process depends on the properties of the plasma emanating from the system. In this study, a plasma analyser comprising a double hemi-spherical electrostatic energy analyser and a quadrupole mass spectrometer, was used to measure the energy distributions of all the ion species leaving a magnetically confined argon plasma, generated in the discharge chamber of a conventional flood neutraliser. The energy distributions extended to surprisingly high energies and the peak structures depended strongly on discharge voltage, discharge current and gas pressure. The nature of these dependencies was complex with both the pressure and arc current affecting the way in which the ion energy distributions depended on arc voltage. In all cases, multiply charged ions played a significant role in determining the nature of the ion energy distributions

  20. Mass and energy analysis of the ions in a plasma flood system

    Energy Technology Data Exchange (ETDEWEB)

    Wooding, A.C. [Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Armour, D.G. [Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Berg, J.A. van den [Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom)]. E-mail: j.a.vandenberg@salford.ac.uk; Holmes, A.J.T. [Marcham Scientific, Hungerford, Berks RG17 0LH (United Kingdom); Burgess, C. [Applied Materials UK Ltd., Foundry Lane, Horsham, West Sussex RH13 5PX (United Kingdom); Goldberg, R.D. [Applied Materials UK Ltd., Foundry Lane, Horsham, West Sussex RH13 5PX (United Kingdom)

    2005-08-01

    Plasma flood systems, capable of providing a copious supply of electrons are used in ion implanters to control wafer charging and provide effective space charge neutralisation of the ion beam in the post-analysis/post-deceleration section of the beamline. Under appropriate conditions the plasma from the flood system interacts with the ion beam and this bridging leads to an enhanced beam transport efficiency in the final critical stage of the beamline. The effectiveness of this process depends on the properties of the plasma emanating from the system. In this study, a plasma analyser comprising a double hemi-spherical electrostatic energy analyser and a quadrupole mass spectrometer, was used to measure the energy distributions of all the ion species leaving a magnetically confined argon plasma, generated in the discharge chamber of a conventional flood neutraliser. The energy distributions extended to surprisingly high energies and the peak structures depended strongly on discharge voltage, discharge current and gas pressure. The nature of these dependencies was complex with both the pressure and arc current affecting the way in which the ion energy distributions depended on arc voltage. In all cases, multiply charged ions played a significant role in determining the nature of the ion energy distributions.

  1. Frequency domain and wavelet analysis of the laser-induced plasma shock waves

    Energy Technology Data Exchange (ETDEWEB)

    Burger, Miloš, E-mail: milosb@ff.bg.ac.rs; Nikolić, Zoran

    2015-08-01

    In addition to optical emission, another trace of interest that laser-induced plasma provides is a form of acoustic feedback. The acoustic emission (AE) signals were obtained using both microphone and piezo transducers. This kind of optoacoustic signals have some distinct features resembling the short, burst-like sounds, that may differ significantly depending mainly on the sample exposed and irradiance applied. Experiments were performed on atmospheric pressure by irradiating various metallic samples. The recorded waveforms were examined and numerically processed. Single-shot acoustical spectra have shown significant potential of providing valuable supplementary information regarding plasma propagation dynamics. Moreover, the general approach suggests the possibility of making the whole measurement system cost-effective and portable. - Highlights: • We report acoustical waveform, and acoustical spectroscopy measurements and analysis in a laser-induced plasma of a different metals in air. • Both piezo and microphone transducer were used. • The acoustical spectra of the emission were obtained when the sample (and plasma) were enclosed in experimental chamber. • The acquired acoustical spectra are time-integrated and the frequency peaks were sharp and relatively isolated. • Finally, both time and frequency resolved wavelet spectrogram present a novel method of observing laser-induced plasma behavior.

  2. Simultaneous Power Deposition Detection of Two EC Beams with the BIS Analysis in Moving TCV Plasmas

    Science.gov (United States)

    Curchod, L.; Pochelon, A.; Decker, J.; Felici, F.; Goodman, T. P.; Moret, J.-M.; Paley, J. I.

    2009-11-01

    Modulation of power amplitude is a widespread to determine the radial absorption profile of externally launched power in fusion plasmas. There are many techniques to analyze the plasma response to such a modulation. The break-in-slope (BIS) analysis can draw an estimated power deposition profile for each power step up. In this paper, the BIS analysis is used to monitor the power deposition location of one or two EC power beams simultaneously in a non-stationary plasma being displaced vertically in the TCV tokamak vessel. Except from radial discrepancies, the results have high time resolution and compare well with simulations from the R2D2-C3PO-LUKE ray-tracing and Fokker-Planck code suite.

  3. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  4. Plasma sample based analysis of gastric cancer progression using targeted metabolomics.

    Science.gov (United States)

    Lario, Sergio; Ramírez-Lázaro, Maria José; Sanjuan-Herráez, Daniel; Brunet-Vega, Anna; Pericay, Carles; Gombau, Lourdes; Junquera, Félix; Quintás, Guillermo; Calvet, Xavier

    2017-12-19

    Gastric carcinogenesis is a multifactorial process described as a stepwise progression from non-active gastritis (NAG), chronic active gastritis (CAG), precursor lesions of gastric cancer (PLGC) and gastric adenocarcinoma. Gastric cancer (GC) 5-year survival rate is highly dependent upon stage of disease at diagnosis, which is based on endoscopy, biopsy and pathological examinations. Non-invasive GC biomarkers would facilitate its diagnosis at early stages leading to improved GC prognosis. We analyzed plasma samples collected from 80 patients diagnosed with NAG without H. pylori infection (NAG-), CAG with H. pylori infection (CAG+), PLGC and GC. A panel of 208 metabolites including acylcarnitines, amino acids and biogenic amines, sphingolipids, glycerophospholipids, hexoses, and tryptophan and phenylalanine metabolites were quantified using two complementary quantitative approaches: Biocrates AbsoluteIDQ®p180 kit and a LC-MS method designed for the analysis of 29 tryptophan pathway and phenylalanine metabolites. Significantly altered metabolic profiles were found in GC patients that allowing discrimination from NAG-, CAG+ and PLGC patients. Pathway analysis showed significantly altered tryptophan and nitrogen metabolic pathways (FDR P < 0.01). Three metabolites (histidine, tryprophan and phenylacetylglutamine) discriminated between non-GC and GC groups. These metabolic signatures open new possibilities to improve surveillance of PLGC patients using a minimally invasive blood analysis.

  5. Electron density and temperature determination in a Tokamak plasma using light scattering

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.; Zurro Hernandez, B.

    1976-01-01

    A theoretical foundation review for light scattering by plasmas is presented. Furthemore, a review of the experimental methods for electron density and temperature measurements, with spatial and time resolution, is included in a Tokamak plasma using spectral analysis of the scattered radiation. (author) [es

  6. Analysis of line integrated electron density using plasma position data on Korea Superconducting Tokamak Advanced Research

    International Nuclear Information System (INIS)

    Nam, Y. U.; Chung, J.

    2010-01-01

    A 280 GHz single-channel horizontal millimeter-wave interferometer system has been installed for plasma electron density measurements on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. This system has a triangular beam path that does not pass through the plasma axis due to geometrical constraints in the superconducting tokamak. The term line density on KSTAR has a different meaning from the line density of other tokamaks. To estimate the peak density and the mean density from the measured line density, information on the position of the plasma is needed. The information has been calculated from tangentially viewed visible images using the toroidal symmetry of the plasma. Interface definition language routines have been developed for this purpose. The calculated plasma position data correspond well to calculation results from magnetic analysis. With the position data and an estimated plasma profile, the peak density and the mean density have been obtained from the line density. From these results, changes of plasma density themselves can be separated from effects of the plasma movements, so they can give valuable information on the plasma status.

  7. Gas chromatography/plasma spectrometry - an important analytical tool for elemental speciation studies

    International Nuclear Information System (INIS)

    Wuilloud, Jorgelina C.A.; Wuilloud, Rodolfo G.; Vonderheide, Anne P.; Caruso, Joseph A.

    2004-01-01

    In this review, a full discussion and update of the state-of-the-art of gas chromatography (GC) coupled to all known plasma spectrometers is presented. A brief introductive discussion of the advantages and disadvantages of GC-plasma interfaces, as well as types of plasmas and mass spectrometers, is given. The plasma-based techniques covered include inductively coupled plasma mass spectrometry (ICP-MS) microwave-induced plasma optical emission spectrometry (MIP-OES), and inductively coupled plasma optical emission spectrometry (ICP-OES). Also, different variants of plasma sources, such as low power plasmas and glow discharge (GD) sources, are described and compared with respect to their capabilities in elemental speciation. Recent advances and alternative mass analyzers (collision/reaction cell; time-of-flight; double-focusing sector field) are also mentioned. Different aspects of the GC-plasma coupling are discussed with particular attention to the applications of these hyphenated techniques to the analysis of elemental species. Additionally, classical and modern sample preparation methods, including extraction and/or preconcentration and derivatization reactions, are presented and evaluated

  8. Analysis of benzoquinone decomposition in solution plasma process

    International Nuclear Information System (INIS)

    Bratescu, M.A.; Saito, N.

    2016-01-01

    The decomposition of p-benzoquinone (p-BQ) in Solution Plasma Processing (SPP) was analyzed by Coherent Anti-Stokes Raman Spectroscopy (CARS) by monitoring the change of the anti-Stokes signal intensity of the vibrational transitions of the molecule, during and after SPP. Just in the beginning of the SPP treatment, the CARS signal intensities of the ring vibrational molecular transitions increased under the influence of the electric field of plasma. The results show that plasma influences the p-BQ molecules in two ways: (i) plasma produces a polarization and an orientation of the molecules in the local electric field of plasma and (ii) the gas phase plasma supplies, in the liquid phase, hydrogen and hydroxyl radicals, which reduce or oxidize the molecules, respectively, generating different carboxylic acids. The decomposition of p-BQ after SPP was confirmed by UV-visible absorption spectroscopy and liquid chromatography

  9. Analysis of benzoquinone decomposition in solution plasma process

    Science.gov (United States)

    Bratescu, M. A.; Saito, N.

    2016-01-01

    The decomposition of p-benzoquinone (p-BQ) in Solution Plasma Processing (SPP) was analyzed by Coherent Anti-Stokes Raman Spectroscopy (CARS) by monitoring the change of the anti-Stokes signal intensity of the vibrational transitions of the molecule, during and after SPP. Just in the beginning of the SPP treatment, the CARS signal intensities of the ring vibrational molecular transitions increased under the influence of the electric field of plasma. The results show that plasma influences the p-BQ molecules in two ways: (i) plasma produces a polarization and an orientation of the molecules in the local electric field of plasma and (ii) the gas phase plasma supplies, in the liquid phase, hydrogen and hydroxyl radicals, which reduce or oxidize the molecules, respectively, generating different carboxylic acids. The decomposition of p-BQ after SPP was confirmed by UV-visible absorption spectroscopy and liquid chromatography.

  10. Computer-aided reduction of plasma data

    International Nuclear Information System (INIS)

    Shariati, S.

    1984-01-01

    Poor signal-to-noise ratios and the non-linear characteristics of the data obtained by most plasma diagnostic equipment makes computer-aided data handling a desirable feature in plasma laboratories. The Lecroy 3500-SA32 signal analyzer is used as the data handling system in this work. The performance of the Lecroy 3500-SA32 signal analyzer, used for recording and reducing the plasma data under the noisy environment of the laboratory, is reported. The data characteristics and software programs are discussed for three types of plasma diagnostic equipment: 1) Langmuir Probes; 2) Charge Exchange Neutral Energy Analyzers; 3) Retarding Potential Energy Analyzers. In order to protect the computer internal circuitry and to have satisfactory data acquisition and handling, methods for dealing with the noisy environment, including stray magnetic fields, RF radiation, and transient spikes on power lines, are also developed. Three computer programs are included which obtain an iterated best fit of experimental data to the corresponding analytical expressions for each case. The new data handling system enables the user to do a real-time analysis of data by using the interactive features of the Lecroy 3500-SA32 system

  11. Plasma probe characteristics in low density hydrogen pulsed plasmas

    International Nuclear Information System (INIS)

    Astakhov, D I; Lee, C J; Bijkerk, F; Goedheer, W J; Ivanov, V V; Krivtsun, V M; Zotovich, A I; Zyryanov, S M; Lopaev, D V

    2015-01-01

    Probe theories are only applicable in the regime where the probe’s perturbation of the plasma can be neglected. However, it is not always possible to know, a priori, that a particular probe theory can be successfully applied, especially in low density plasmas. This is especially difficult in the case of transient, low density plasmas. Here, we applied probe diagnostics in combination with a 2D particle-in-cell model, to an experiment with a pulsed low density hydrogen plasma. The calculations took into account the full chamber geometry, including the plasma probe as an electrode in the chamber. It was found that the simulations reproduce the time evolution of the probe IV characteristics with good accuracy. The disagreement between the simulated and probe measured plasma density is attributed to the limited applicability of probe theory to measurements of low density pulsed plasmas on a similarly short time scale as investigated here. Indeed, in the case studied here, probe measurements would lead to, either a large overestimate, or underestimate of the plasma density, depending on the chosen probe theory. In contrast, the simulations of the plasma evolution and the probe characteristics do not suffer from such strict applicability limits. These studies show that probe theory cannot be justified through probe measurements. However, limiting cases of probe theories can be used to estimate upper and lower bounds on plasma densities. These theories include and neglect orbital motion, respectively, with different collisional terms leading to intermediate estimates. (paper)

  12. Trends of Blood and Plasma Donations in Kazakhstan: 12-Years Retrospective Analysis.

    Science.gov (United States)

    Igissinov, Nurbek; Kulmirzayeva, Dariyana; Magzumova, Raushan; Sibinga, Cees Th Smit; Alpeissova, Sholpan

    2014-05-01

    Each country faces a continuing challenge to collect enough blood to meet the national needs. According to WHO, there should be at least 20 blood donations per 1,000 population for developing countries, in Kazakhstan this indicator was only 16.8 in 2011. Thus, we conducted an epidemiological assessment and drew a map of the regional distribution of blood and plasma donations in Kazakhstan during the years 2000-2011. The retrospective study was conducted from 2000 to 2011. Data on blood and its components donations were acquired from the Ministry of Health (annual statistical reporting form N° 39). During 2000-2011, number of blood donors decreased to 17.4% and blood donations to 6.3%. The proportion of non-remunerated blood donations and donors decreased from 97.6% to 77.9% and 97.9% to 87.7%, respectively. The paid donations had the opposite trend. Number of plasma donors increased in 2.1 times, plasma donations in 2.4 times, nevertheless the proportion of non-remunerated plasma donations decreased from 60.1% to 29.8%. The average number of blood donations per 1,000 population decreased from 19.8 (2000) to 16.8 (2011), plasma donations increased from 1.4 to 3.1. Regionally, annual average rates of blood and plasma donations per 1,000 population over 12 years varied greatly. This is the first study conducted in Kazakhstan to provide detailed information, including the regional characteristics of blood and plasma donations over an extended period of time, which can be used in blood transfusion services work.

  13. Electron density and temperature determination in a Tokamak plasma using light scattering

    International Nuclear Information System (INIS)

    Perez-Navarro Gomerz, A.; Zurro Hernandez, B.

    1976-01-01

    A theoretical foundation review for light scattering by plasmas is presented. Furthermore, we have included a review of the experimental methods for electron density and temperature measurements, with spatial and time resolution, in a Tokamak plasma using spectral analysis of the scattered radiation. (Author) 13 refs

  14. Measurement of thermal plasma jet temperature and velocity by laser light lineshape analysis

    International Nuclear Information System (INIS)

    Snyder, S.C.; Reynolds, L.D.

    1991-01-01

    Two important parameters of thermal plasma jets are kinetic or gas temperatures and flow velocity. Gas temperatures have been traditionally measured using emission spectroscopy, but this method depends on either the generally unrealistic assumption of the existence of local thermodynamic equilibrium (LTE) within the plasma, or the use of various non-LTE or partial LTE models to relate the intensity of the emission lines to the gas temperature. Plasma jet velocities have been measured using laser Doppler velocimetry on particles injected into the plasma. However, this method is intrusive and it is not known how well the particle velocities represent the gas velocity. Recently, plasma jet velocities have been measured from the Doppler shift of laser light scattered by the plasma. In this case, the Doppler shift was determined from the difference in the transmission profile of a high resolution monochromator between red shifted and blue shifted scattered light. A direct approach to measuring localized temperatures and velocities is afforded by high resolution scattered light lineshape measurements. The linewidth of laser light scattered by atoms and ions can be related to the kinetic temperature without LTE assumptions, while a shift in the peak position relative to the incident laser lineshape yields the gas velocity. We report in this paper work underway to measure gas temperatures and velocities in an argon thermal plasma jet using high resolution lineshape analysis of scattered laser light

  15. Multi-physics modeling of plasma-material interactions

    Science.gov (United States)

    Lasa, Ane; Green, David; Canik, John; Younkin, Timothy; Blondel, Sophie; Wirth, Brian; Drobny, Jon; Curreli, Davide

    2017-10-01

    Plasma-material interactions (PMI) can degrade both plasma and material properties. Often, PMI modeling focuses on either the plasma or surface. Here, we present an integrated model with high-fidelity codes coupled within the IPS framework that self-consistently addresses PMI. The model includes, calculation of spatially resolved influx of plasma and impurities to the surface and their implantation; surface erosion and roughening; evolution of implanted species and sub-surface composition; and transport of eroded particles across the plasma and their re-deposition. The model is applied and successfully compared to dedicated PISCES linear device experiments, where a tungsten (W) target was exposed to helium (He) plasma. The present contribution will focus on the analysis of W erosion, He retention and sub-surface gas bubble and surface composition evolution, under the different He plasma conditions across the surface that are calculated by impurity transport modeling. Impact of code coupling, reflected as interplay between surface erosion, fuel / impurity implantation and retention, and evolution of target composition, as well as sensitivity of these processes to plasma exposure conditions is also analyzed in detail. This work is supported by the US DOE under contract DE-AC05-00OR22725.

  16. Prognostic significance of pretreatment plasma fibrinogen level in patients with digestive system tumors: a meta-analysis.

    Science.gov (United States)

    Ji, Rui; Ren, Qian; Bai, Suyang; Wang, Yuping; Zhou, Yongning

    2018-06-01

    High pretreatment levels of plasma fibrinogen have been widely reported to be a potential predictor of prognosis in digestive system tumors; however, the conclusions are not consistent. Therefore, we performed a meta-analysis to comprehensively assess the prognostic roles of high pretreatment plasma fibrinogen levels in digestive system tumors. We searched for eligible studies in the PubMed, Embase, and Web of Science electronic databases for publications from the database inception to 1 September 2017. The endpoints of interest included overall survival, disease-free survival, and recurrence-free survival. We investigated the relationship between fibrinogenemia and overall survival in colorectal cancer (10 studies), gastric cancer (6), pancreatic cancer (6), hepatocellular carcinoma (7), and esophageal squamous cell carcinoma (10); the pooled results indicated that fibrinogenemia was significantly related to a worse overall survival (hazard ratio (HR) 1.73; 95% confidence interval (CI) 1.52, 1.97; P digestive system tumors, indicating that it could be a useful prognostic marker in these types of tumors.

  17. Web interface for plasma analysis codes

    Energy Technology Data Exchange (ETDEWEB)

    Emoto, M. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan)], E-mail: emo@nifs.ac.jp; Murakami, S. [Kyoto University, Yoshida-Honmachi, Sakyo-ku, Kyoto 606-8501 (Japan); Yoshida, M.; Funaba, H.; Nagayama, Y. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan)

    2008-04-15

    There are many analysis codes that analyze various aspects of plasma physics. However, most of them are FORTRAN programs that are written to be run in supercomputers. On the other hand, many scientists use GUI (graphical user interface)-based operating systems. For those who are not familiar with supercomputers, it is a difficult task to run analysis codes in supercomputers, and they often hesitate to use these programs to substantiate their ideas. Furthermore, these analysis codes are written for personal use, and the programmers do not expect these programs to be run by other users. In order to make these programs to be widely used by many users, the authors developed user-friendly interfaces using a Web interface. Since the Web browser is one of the most common applications, it is useful for both the users and developers. In order to realize interactive Web interface, AJAX technique is widely used, and the authors also adopted AJAX. To build such an AJAX based Web system, Ruby on Rails plays an important role in this system. Since this application framework, which is written in Ruby, abstracts the Web interfaces necessary to implement AJAX and database functions, it enables the programmers to efficiently develop the Web-based application. In this paper, the authors will introduce the system and demonstrate the usefulness of this approach.

  18. Web interface for plasma analysis codes

    International Nuclear Information System (INIS)

    Emoto, M.; Murakami, S.; Yoshida, M.; Funaba, H.; Nagayama, Y.

    2008-01-01

    There are many analysis codes that analyze various aspects of plasma physics. However, most of them are FORTRAN programs that are written to be run in supercomputers. On the other hand, many scientists use GUI (graphical user interface)-based operating systems. For those who are not familiar with supercomputers, it is a difficult task to run analysis codes in supercomputers, and they often hesitate to use these programs to substantiate their ideas. Furthermore, these analysis codes are written for personal use, and the programmers do not expect these programs to be run by other users. In order to make these programs to be widely used by many users, the authors developed user-friendly interfaces using a Web interface. Since the Web browser is one of the most common applications, it is useful for both the users and developers. In order to realize interactive Web interface, AJAX technique is widely used, and the authors also adopted AJAX. To build such an AJAX based Web system, Ruby on Rails plays an important role in this system. Since this application framework, which is written in Ruby, abstracts the Web interfaces necessary to implement AJAX and database functions, it enables the programmers to efficiently develop the Web-based application. In this paper, the authors will introduce the system and demonstrate the usefulness of this approach

  19. Method and apparatus for monitoring plasma processing operations

    Science.gov (United States)

    Smith, Jr., Michael Lane; Ward, Pamela Denise Peardon; Stevenson, Joel O'Don

    2002-01-01

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). Another aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system. A final aspect of the present invention relates to a network a plurality of plasma monitoring systems, including with remote capabilities (i.e., outside of the clean room).

  20. Mathematical and numerical analysis of plasma stability

    International Nuclear Information System (INIS)

    Saramito, B.

    1987-11-01

    Equilibrium of a tokamak plasma is analyzed using two two-dimensional numerical models. Plasma configuration; convection in a cylindrical plasma layer; and tearing instabilities in a flat layer are considered. The finite element code used is explained. The existence of analogous stationary solutions for a problem concerning compressible fluids is shown. Stationary convection created by the equilibrium density gradient is treated. Approximation using fluid equations is employed in the case of convection resulting from the equilibrium temperature gradient. Evolution towards turbulence of incompressible fluid models is followed [fr

  1. Dusty plasmas

    International Nuclear Information System (INIS)

    Jones, M.E.; Winske, D.; Keinigs, R.; Lemons, D.

    1996-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The objective of this project has been to develop a fundamental understanding of dusty plasmas at the Laboratory. While dusty plasmas are found in space in galactic clouds, planetary rings, and cometary tails, and as contaminants in plasma enhanced fabrication of microelectronics, many of their properties are only partially understood. Our work has involved both theoretical analysis and self-consistent plasma simulations to understand basic properties of dusty plasmas related to equilibrium, stability, and transport. Such an understanding can improve the control and elimination of plasma dust in industrial applications and may be important in the study of planetary rings and comet dust tails. We have applied our techniques to the study of charging, dynamics, and coagulation of contaminants in plasma processing reactors for industrial etching and deposition processes and to instabilities in planetary rings and other space plasma environments. The work performed in this project has application to plasma kinetics, transport, and other classical elementary processes in plasmas as well as to plasma waves, oscillations, and instabilities

  2. Analysis of plasma channels in mm-scale plasmas formed by high intensity laser beams

    International Nuclear Information System (INIS)

    Murakami, R; Habara, H; Iwawaki, T; Uematsu, Y; Tanaka, K A; Ivancic, S; Anderson, K; Haberberger, D; Stoeckl, C; Theobald, W; Sakagami, H

    2016-01-01

    A plasma channel created by a high intensity infrared laser beam was observed in a long scale-length plasma (L ∼ 240 μm) with the angular filter refractometry technique, which indicated a stable channel formation up to the critical density. We analyzed the observed plasma channel using a rigorous ray-tracing technique, which provides a deep understanding of the evolution of the channel formation. (paper)

  3. Scaling of plasma turbulence resulting from parametric instabilities

    International Nuclear Information System (INIS)

    Ott, E.

    1976-01-01

    Dimensional analysis is used to obtain results on the turbulent state resulting from parametric instabilities of an initially cold plasma. The results include the possibility of an applied magnetic field, multiple ion species, and arbitrary dimensionality

  4. Higher intake of fish and fat is associated with lower plasma s-adenosylhomocysteine

    DEFF Research Database (Denmark)

    Lind, Mads Vendelbo; Lauritzen, Lotte; Pedersen, Oluf Borbye

    2017-01-01

    . In addition we assessed whole-blood fatty acid composition and plasma alkylresorcinols. Plasma s-adenosylmethionine (SAM), s-adenosylhomocysteine (SAH), homocysteine (Hcy) and vitamin B12 was included as one-carbon metabolism markers. We used principal component analysis (PCA) to explore dietary patterns...

  5. Multiplexed LC-MS/MS analysis of horse plasma proteins to study doping in sport.

    Science.gov (United States)

    Barton, Chris; Beck, Paul; Kay, Richard; Teale, Phil; Roberts, Jane

    2009-06-01

    The development of protein biomarkers for the indirect detection of doping in horse is a potential solution to doping threats such as gene and protein doping. A method for biomarker candidate discovery in horse plasma is presented using targeted analysis of proteotypic peptides from horse proteins. These peptides were first identified in a novel list of the abundant proteins in horse plasma. To monitor these peptides, an LC-MS/MS method using multiple reaction monitoring was developed to study the quantity of 49 proteins in horse plasma in a single run. The method was optimised and validated, and then applied to a population of race-horses to study protein variance within a population. The method was finally applied to longitudinal time courses of horse plasma collected after administration of an anabolic steroid to demonstrate utility for hypothesis-driven discovery of doping biomarker candidates.

  6. TRACE ANALYSIS BY LASER-EXCITED ATOMIC FLUORESCENCE WITH ATOMIZATION IN A PULSED PLASMA

    OpenAIRE

    Lunyov , O.; Oshemkov , S.; Petrov , A.

    1991-01-01

    The possibilities of plasma atomization for laser fluorescence trace analysis are discussed. Pulsed hot hollow cathode discharge was used for analysis of solutions and powdered samples. The high voltage spark and laser-induced breakdown (laser spark) were used as atomizers of metal-containing atmospheric aerosols. Detection limits were improved by means of temporal background selection.

  7. Nonlinear waves in electron-positron-ion plasmas including charge separation

    Science.gov (United States)

    Mugemana, A.; Moolla, S.; Lazarus, I. J.

    2017-02-01

    Nonlinear low-frequency electrostatic waves in a magnetized, three-component plasma consisting of hot electrons, hot positrons and warm ions have been investigated. The electrons and positrons are assumed to have Boltzmann density distributions while the motion of the ions are governed by fluid equations. The system is closed with the Poisson equation. This set of equations is numerically solved for the electric field. The effects of the driving electric field, ion temperature, positron density, ion drift, Mach number and propagation angle are investigated. It is shown that depending on the driving electric field, ion temperature, positron density, ion drift, Mach number and propagation angle, the numerical solutions exhibit waveforms that are sinusoidal, sawtooth and spiky. The introduction of the Poisson equation increased the Mach number required to generate the waveforms but the driving electric field E 0 was reduced. The results are compared with satellite observations.

  8. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  9. PlasmaPy: initial development of a Python package for plasma physics

    Science.gov (United States)

    Murphy, Nicholas; Leonard, Andrew J.; Stańczak, Dominik; Haggerty, Colby C.; Parashar, Tulasi N.; Huang, Yu-Min; PlasmaPy Community

    2017-10-01

    We report on initial development of PlasmaPy: an open source community-driven Python package for plasma physics. PlasmaPy seeks to provide core functionality that is needed for the formation of a fully open source Python ecosystem for plasma physics. PlasmaPy prioritizes code readability, consistency, and maintainability while using best practices for scientific computing such as version control, continuous integration testing, embedding documentation in code, and code review. We discuss our current and planned capabilities, including features presently under development. The development roadmap includes features such as fluid and particle simulation capabilities, a Grad-Shafranov solver, a dispersion relation solver, atomic data retrieval methods, and tools to analyze simulations and experiments. We describe several ways to contribute to PlasmaPy. PlasmaPy has a code of conduct and is being developed under a BSD license, with a version 0.1 release planned for 2018. The success of PlasmaPy depends on active community involvement, so anyone interested in contributing to this project should contact the authors. This work was partially supported by the U.S. Department of Energy.

  10. A self-similar model for conduction in the plasma erosion opening switch

    International Nuclear Information System (INIS)

    Mosher, D.; Grossmann, J.M.; Ottinger, P.F.; Colombant, D.G.

    1987-01-01

    The conduction phase of the plasma erosion opening switch (PEOS) is characterized by combining a 1-D fluid model for plasma hydrodynamics, Maxwell's equations, and a 2-D electron-orbit analysis. A self-similar approximation for the plasma and field variables permits analytic expressions for their space and time variations to be derived. It is shown that a combination of axial MHD compression and magnetic insulation of high-energy electrons emitted from the switch cathode can control the character of switch conduction. The analysis highlights the need to include additional phenomena for accurate fluid modeling of PEOS conduction

  11. Plasma and cerebrospinal fluid amyloid-β levels in late-life depression: a systematic review and meta-analysis

    Science.gov (United States)

    do Nascimento, Kenia Kelly Fiaux; Silva, Kelly P.; Malloy-Diniz, Leandro F.; Butters, Meryl A.; Diniz, Breno S.

    2016-01-01

    This study aimed to evaluate differences in plasma and cerebrospinal fluid (CSF) levels of Aβ peptides in older adults with late-life depression compared to non-depressed older controls. We conducted a systematic review and meta-analysis of the literature using PubMed, Web of science and Scopus databases with no search limits for publication dates or languages. Two independent reviewers extracted data and assessed quality. Six hundred references were retrieved, and we included 12 studies in the meta-analysis after eligibility screening. Older adults with late-life depression (LLD) had a higher plasma Aβ40:Aβ42 ratio compared to non-depressed participants (SMD= 1.10, CI95% [0.28; 1.96], p=0.01), and marginally significant reduction of CSF Aβ42 levels (SMD= −1.12, CI95% [−2.47; 0.22], p=0.1). The present results evidence that older adults with depression have significant differences in Aβ metabolism, in the same direction observed in individuals with AD. These differences in the Aβ metabolism may help identify a subgroup of subjects with LLD at higher risk of developing AD. PMID:26343592

  12. 40 CFR 60.1125 - What must I include in my siting analysis?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What must I include in my siting... § 60.1125 What must I include in my siting analysis? (a) Include an analysis of how your municipal...) Vegetation. (b) Include an analysis of alternatives for controlling air pollution that minimize potential...

  13. Technical information report: Plasma melter operation, reliability, and maintenance analysis

    International Nuclear Information System (INIS)

    Hendrickson, D.W.

    1995-01-01

    This document provides a technical report of operability, reliability, and maintenance of a plasma melter for low-level waste vitrification, in support of the Hanford Tank Waste Remediation System (TWRS) Low-Level Waste (LLW) Vitrification Program. A process description is provided that minimizes maintenance and downtime and includes material and energy balances, equipment sizes and arrangement, startup/operation/maintence/shutdown cycle descriptions, and basis for scale-up to a 200 metric ton/day production facility. Operational requirements are provided including utilities, feeds, labor, and maintenance. Equipment reliability estimates and maintenance requirements are provided which includes a list of failure modes, responses, and consequences

  14. Neoclassical rotation velocities in multispecies plasmas

    International Nuclear Information System (INIS)

    Houlberg, W.A.; Hirshman, S.P.; Shaing, K.C.

    1996-01-01

    We examine the relationships between the poloidal, toroidal and parallel rotation velocities for typical plasma conditions in existing tokamak experiments. The radial force balance, neoclassical solution to the poloidal flow from the parallel force balance, and anomalous toroidal rotation axe included. A full multispecies formulation of the neoclassical transport theory is implemented in the NCLASS code (which includes arbitrary axisymmetric geometries and plasma collisionalities) to determine the poloidal rotation velocities. Comparisons are made with analytic relationships derived from a single impurity formulation of the problem. The roles of the radial electric field and species density and pressure gradients are evaluated. The determination of the radial electric field using the NCLASS solution for poloidal rotation and a local measurement of the toroidal rotation in conjunction with measured plasma profiles is discussed; it has been used in analysis of TFTR enhanced reverse shear plasmas. The ordering of banana orbit size small relative to local minor radius and gradients (as incorporated into initial versions of NCLASS) are examined for typical negative shear plasmas. We show the degree to which these constraints axe violated and demonstrate that finite orbit corrections axe required for better determination of the bootstrap current, particle fluxes and ion heat fluxes, i.e., the conditions r much-lt Δ b much-lt r n , r T , r E are significantly violated. Progress in relaxing these constraints is discussed

  15. Elemental analysis of bead samples using a laser-induced plasma at low pressure

    International Nuclear Information System (INIS)

    Lie, Tjung Jie; Kurniawan, Koo Hendrik; Kurniawan, Davy P.; Pardede, Marincan; Suliyanti, Maria Margaretha; Khumaeni, Ali; Natiq, Shouny A.; Abdulmadjid, Syahrun Nur; Lee, Yong Inn; Kagawa, Kiichiro; Idris, Nasrullah; Tjia, May On

    2006-01-01

    An Nd:YAG laser (1064 nm, 8 ns, 30 mJ) was focused on various types of fresh, fossilized white coral and giant shell samples, including samples of imitation shell and marble. Such samples are extremely important as material for preparing prayer beads that are extensively used in the Buddhist faith. The aim of this research was to develop a non-destructive method to distinguish original beads from their imitations by means of spectral measurements of the carbon, hydrogen, sodium and magnesium emission intensities and by measuring the hardness of the sample using the ratio between Ca (II) 396.8 nm and Ca (I) 422.6 nm. Based on these measurements, original fresh coral beads can be distinguished from any imitation made from hard wood. The same technique was also effective in distinguishing beads made of shell from its imitation. A spectral analysis of bead was also performed on a fossilized white coral sample and the result can be used to distinguish to some extent the fossilized white coral beads from any imitation made from marble. It was also found that the plasma plume should be generated at low ambient pressure to significantly improve the hydrogen and carbon emission intensity and also to avoid energy loss inside the crater during laser irradiation at atmospheric pressure. The results of this study confirm that operating the laser-induced plasma spectroscopy at reduced ambient pressure offers distinct advantage for bead analysis over the conventional laser-induced breakdown spectroscopy (LIBS) technique operated at atmospheric pressure

  16. Elemental analysis of bead samples using a laser-induced plasma at low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Lie, Tjung Jie [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia); Kurniawan, Koo Hendrik [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia)]. E-mail: kurnia18@cbn.net.id; Kurniawan, Davy P. [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia); Pardede, Marincan [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia); Suliyanti, Maria Margaretha [Graduate Program in Opto Electrotechniques and Laser Applications, Faculty of Engineering, The University of Indonesia, 4 Salemba Raya, Jakarta 10430 (Indonesia); Khumaeni, Ali [Department of Physics, Faculty of Mathematics and Natural Sciences, Diponegoro University, Tembalang Campus, Semarang 50275 (Indonesia); Natiq, Shouny A. [Department of Physics, Faculty of Mathematics and Natural Sciences, Diponegoro University, Tembalang Campus, Semarang 50275 (Indonesia); Abdulmadjid, Syahrun Nur [Department of Physics, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Darussalam, Banda Aceh 23116 (Indonesia); Lee, Yong Inn [Physics Department, Chonbuk National University, Chonju 561-756, South Korea (Korea); Kagawa, Kiichiro [Department of Physics, Faculty of Education and Regional Studies, Fukui University, 9-1 bunkyo 3-chome, Fukui 910-8507 (Japan); Idris, Nasrullah [Department of Physics, Faculty of Education and Regional Studies, Fukui University, 9-1 bunkyo 3-chome, Fukui 910-8507 (Japan); Tjia, May On [Department of Physics, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, 10 Ganesha, Bandung 40132 (Indonesia)

    2006-01-15

    An Nd:YAG laser (1064 nm, 8 ns, 30 mJ) was focused on various types of fresh, fossilized white coral and giant shell samples, including samples of imitation shell and marble. Such samples are extremely important as material for preparing prayer beads that are extensively used in the Buddhist faith. The aim of this research was to develop a non-destructive method to distinguish original beads from their imitations by means of spectral measurements of the carbon, hydrogen, sodium and magnesium emission intensities and by measuring the hardness of the sample using the ratio between Ca (II) 396.8 nm and Ca (I) 422.6 nm. Based on these measurements, original fresh coral beads can be distinguished from any imitation made from hard wood. The same technique was also effective in distinguishing beads made of shell from its imitation. A spectral analysis of bead was also performed on a fossilized white coral sample and the result can be used to distinguish to some extent the fossilized white coral beads from any imitation made from marble. It was also found that the plasma plume should be generated at low ambient pressure to significantly improve the hydrogen and carbon emission intensity and also to avoid energy loss inside the crater during laser irradiation at atmospheric pressure. The results of this study confirm that operating the laser-induced plasma spectroscopy at reduced ambient pressure offers distinct advantage for bead analysis over the conventional laser-induced breakdown spectroscopy (LIBS) technique operated at atmospheric pressure.

  17. Thermal stability of the tokamak plasma edge

    International Nuclear Information System (INIS)

    Stacey, W.M.

    1997-01-01

    The general linear, fluid, thermal instability theory for the plasma edge has been extended. An analysis of a two-dimensional fluid model of the plasma edge has identified the importance of many previously unappreciated phenomena associated with parallel and gyroviscous forces in the presence of large radial gradients, with large radial or parallel flows, with the temperature dependence of transport coefficients, and with the coupling of temperature, flow and density perturbations. The radiative condensation effect is generalized to include a further destabilizing condensation effect associated with radial heat conduction. Representative plasma edge neutral and impurity densities are found to be capable of driving thermal instabilities in the edge transport barrier and radiative mantle, respectively. (author)

  18. Nonlinear Electron Waves in Strongly Magnetized Plasmas

    DEFF Research Database (Denmark)

    Pécseli, Hans; Juul Rasmussen, Jens

    1980-01-01

    Weakly nonlinear dispersive electron waves in strongly magnetized plasma are considered. A modified nonlinear Schrodinger equation is derived taking into account the effect of particles resonating with the group velocity of the waves (nonlinear Landau damping). The possibility of including the ion...... dynamics in the analysis is also demonstrated. As a particular case the authors investigate nonlinear waves in a strongly magnetized plasma filled wave-guide, where the effects of finite geometry are important. The relevance of this problem to laboratory experiments is discussed....

  19. Spectroscopic analysis applied to temperature measurement in plasmas

    International Nuclear Information System (INIS)

    Fieffe-Prevost, P.

    1978-01-01

    The plasma temperature is defined only if the plasma is in a state near thermodynamic equilibrium. This plasma state is analysed in detail and spectroscopic methods for measuring the temperature are discussed. As an application the hydrogen arc of the National Institute of Metrology of the Conservatoire National des Arts et Metiers (Paris) is briefly described [fr

  20. The expanding plasma jet

    International Nuclear Information System (INIS)

    Sanden, M.C.M. van den.

    1991-01-01

    This thesis concerns the fundamental aspects of an argon plasma expanding from a cascaded arc. This type of plasma is not only used for fundamental research but also for technologically orientated research on plasma deposition and plasma sources. The important characteristics of the plasma are a strong supersonic expansion in which the neutral particle and ion densities decrease three orders of magnitude, followed by a stationary shock front. After the shock front the plasma expands further subsonically. A part of this thesis is devoted to the discussion of a newly constructed combined Thomson-Rayleigh scattering set up. With this set up the electron density, the electron temperature and the neutral particle density are measured locally in the plasma for different conditions. In the analysis of the measured spectra weak coherent effects and the measured apparatus profile are included. The inaccuracies are small, ranging from 1 to 4 percent for the electron density and 2 to 6 percent for the electron temperature, depending on the plasma conditions. The inaccuracy of the neutral particle density determination is larger and ranges from 10 to 50 percent. The detection limits for the electron and neutral particle density are 7.10 17 m -3 and 1.10 20 m -3 respectively. A side path in this thesis is the derivation of the Saha equation for a two-temperature plasma. The reason for this derivation was the dispute in the literature about the correct form of this equation. In this thesis it is shown, from the correct extension of the second law of thermodynamics and from the non-equilibrium formalism of Zubarev, That in the limit of m e /m h ->0 the generalized Saha equation depends on the electron temperature only. (author). 221 refs.; 54 figs.; 13 tabs

  1. Summary report : working group 5 on 'electron beam-driven plasma and structure based acceleration concepts'

    International Nuclear Information System (INIS)

    Conde, M. E.; Katsouleas, T.

    2000-01-01

    The talks presented and the work performed on electron beam-driven accelerators in plasmas and structures are summarized. Highlights of the working group include new experimental results from the E-157 Plasma Wakefield Experiment, the E-150 Plasma Lens Experiment and the Argonne Dielectric Structure Wakefield experiments. The presentations inspired discussion and analysis of three working topics: electron hose instability, ion channel lasers and the plasma afterburner

  2. Analysis of Proteolytic and Fibrinolytic Activity of the Blood Plasma in Patients with Bronchial Asthma Combined with Obesity

    Directory of Open Access Journals (Sweden)

    Fediv A.I. Fediv A.I.

    2016-09-01

    Full Text Available Aim of the study — to conduct the analysis of the performance of proteolytic and fibrinolytic activity of the blood plasma in patients with bronchial asthma (BA combined with obesity. Materials and methods. The study included 40 patients divided into groups. The basic group consisted of 20 patients with BA associated with obesity (ІI group, two comparison groups — of 10 patients with BA and normal body weight (I group and 10 patients with obesity and without pathology of the bronchopulmonary system (ІІІ group. Control group included 10 apparently healthy persons. In patients with BA, there were investigated the indexes of proteolytic and fibrinolytic activity of the blood plasma. Results. Analysis of the obtained data in patients with BA showed an increase of activity of plasma coagulation factors: total fibrinolytic activity increased in comparison to the control group, and in patients with BA it was 1.46 ± 0.13 Е440/ml/h, while in apparently healthy persons — 1.23 ± 0.16 Е440/ml/h (р < 0.05. In addition, an increase was marked and in the group of patients with the isolated obesity (by 38.5 % as compared to the group of apparently healthy persons, that can be explained by the growth of activity of inflammatory process due to the immune changes related to biological activity of fatty tissue as an additional source of proinflammatory cytokines. Conclusions. In combination of bronchial asthma and obesity, there is an activation of fibrinolytic and proteolytic systems of the blood that leads to microcirculatory and hemostatic disorders, enhancement of inflammatory process. In obesity as the state of systemic inflammatory response, the activation of fibrinolytic and proteolytic blood systems is more significant, than in bronchial asthma.

  3. A Simple Plasma Retinol Isotope Ratio Method for Estimating β-Carotene Relative Bioefficacy in Humans: Validation with the Use of Model-Based Compartmental Analysis.

    Science.gov (United States)

    Ford, Jennifer Lynn; Green, Joanne Balmer; Lietz, Georg; Oxley, Anthony; Green, Michael H

    2017-09-01

    Background: Provitamin A carotenoids are an important source of dietary vitamin A for many populations. Thus, accurate and simple methods for estimating carotenoid bioefficacy are needed to evaluate the vitamin A value of test solutions and plant sources. β-Carotene bioefficacy is often estimated from the ratio of the areas under plasma isotope response curves after subjects ingest labeled β-carotene and a labeled retinyl acetate reference dose [isotope reference method (IRM)], but to our knowledge, the method has not yet been evaluated for accuracy. Objectives: Our objectives were to develop and test a physiologically based compartmental model that includes both absorptive and postabsorptive β-carotene bioconversion and to use the model to evaluate the accuracy of the IRM and a simple plasma retinol isotope ratio [(RIR), labeled β-carotene-derived retinol/labeled reference-dose-derived retinol in one plasma sample] for estimating relative bioefficacy. Methods: We used model-based compartmental analysis (Simulation, Analysis and Modeling software) to develop and apply a model that provided known values for β-carotene bioefficacy. Theoretical data for 10 subjects were generated by the model and used to determine bioefficacy by RIR and IRM; predictions were compared with known values. We also applied RIR and IRM to previously published data. Results: Plasma RIR accurately predicted β-carotene relative bioefficacy at 14 d or later. IRM also accurately predicted bioefficacy by 14 d, except that, when there was substantial postabsorptive bioconversion, IRM underestimated bioefficacy. Based on our model, 1-d predictions of relative bioefficacy include absorptive plus a portion of early postabsorptive conversion. Conclusion: The plasma RIR is a simple tracer method that accurately predicts β-carotene relative bioefficacy based on analysis of one blood sample obtained at ≥14 d after co-ingestion of labeled β-carotene and retinyl acetate. The method also provides

  4. Analysis of the interaction of deuterium plasmas with tungsten in the Fuego-Nuevo II device

    Science.gov (United States)

    Ramos, Gonzalo; Castillo, Fermín; Nieto, Martín; Martínez, Marco; Rangel, José; Herrera-Velázquez, Julio

    2012-10-01

    Tungsten is one of the main candidate materials for plasma-facing components in future fusion power plants. The Fuego-Nuevo II, a plasma focus device, which can produce dense magnetized helium and deuterium plasmas, has been adapted to address plasma-facing materials questions. In this paper we present results of tungsten targets exposed to deuterium plasmas in the Fuego Nuevo II device, using different experimental conditions. The plasma generated and accelerated in the coaxial gun is expected to have, before the pinch, energies of the order of hundreds eV and velocities of the order of 40,000 m s-1. At the pinch, the ions are reported to have energies of the order of 1.5 keV at most. The samples, analysed with a scanning electron microscope (SEM) in cross section show a damage profile to depths of the order of 580 nm, which are larger than those expected for ions with 1.5 keV, and may be evidence of ion acceleration. An analysis with the SRIM (Stopping Range of Ions in Matter) package calculations is shown.

  5. Plasma metabolic profiling analysis of toxicity induced by brodifacoum using metabonomics coupled with multivariate data analysis.

    Science.gov (United States)

    Yan, Hui; Qiao, Zheng; Shen, Baohua; Xiang, Ping; Shen, Min

    2016-10-01

    Brodifacoum is one of the most widely used rodenticides for rodent control and eradication; however, human and animal poisoning due to primary and secondary exposure has been reported since its development. Although numerous studies have described brodifacoum induced toxicity, the precise mechanism still needs to be explored. Gas chromatography mass spectrometry (GC-MS) coupled with an ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was applied to characterize the metabolic profile of brodifacoum induced toxicity and discover potential biomarkers in rat plasma. The toxicity of brodifacoum was dose-dependent, and the high-dose group obviously manifested toxicity with subcutaneous hemorrhage. The blood brodifacoum concentration showed a positive relation to the ingestion dose in toxicological analysis. Significant changes of twenty-four metabolites were identified and considered as potential toxicity biomarkers, primarily involving glucose metabolism, lipid metabolism and amino acid metabolism associated with anticoagulant activity, nephrotoxicity and hepatic damage. MS-based metabonomics analysis in plasma samples is helpful to search for potential poisoning biomarkers and to understand the underlying mechanisms of brodifacoum induced toxicity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Super-transition-arrays: A model for the spectral analysis of hot, dense plasma

    International Nuclear Information System (INIS)

    Bar-Shalom, A.; Oreg, J.; Goldstein, W.H.; Shvarts, D.; Zigler, A.

    1989-01-01

    A method is presented for calculating the bound-bound emission from a local thermodynamic equilibrium plasma. The total transition array of a specific single-electron transition, including all possible contributing configurations, is described by only a small number of super-transition-arrays (STA's). Exact analytic expressions are given for the first few moments of an STA. The method is shown to interpolate smoothly between the average-atom (AA) results and the detailed configuration accounting that underlies the unresolved transition array (UTA) method. Each STA is calculated in its own, optimized potential, and the model achieves rapid convergence in the number of STA's included. Comparisons of predicted STA spectra with the results of the AA and UTA methods are presented. It is shown that under certain plasma conditions the contributions of low-probability transitions can accumulate into an important component of the emission. In these cases, detailed configuration accounting is impractical. On the other hand, the detailed structure of the spectrum under such conditions is not described by the AA method. The application of the STA method to laser-produced plasma experiments is discussed

  7. Variation in plasma calcium analysis in primary care in Sweden - a multilevel analysis

    Directory of Open Access Journals (Sweden)

    Eggertsen Robert

    2010-05-01

    Full Text Available Abstract Background Primary hyperparathyroidism (pHPT is a common disease that often remains undetected and causes severe disturbance especially in postmenopausal women. Therefore, national recommendations promoting early pHPT detection by plasma calcium (P-Ca have been issued in Sweden. In this study we aimed to investigate variation of P-Ca analysis between physicians and health care centres (HCCs in primary care in county of Skaraborg, Sweden. Methods In this cross sectional study of patients' records during 2005 we analysed records from 154 629 patients attending 457 physicians at 24 HCCs. We used multilevel logistic regression analysis (MLRA and adjusted for patient, physician and HCC characteristics. Differences were expressed as median odds ratio (MOR. Results There was a substantial variation in number of P-Ca analyses between both HCCs (MORHCC 1.65 [1.44-2.07] and physicians (MORphysician 1.95 [1.85-2.08]. The odds for a P-Ca analysis were lower for male patients (OR 0.80 [0.77-0.83] and increased with the number of diagnoses (OR 25.8 [23.5-28.5]. Sex of the physician had no influence on P-Ca test ordering (OR 0.93 [0.78-1.09]. Physicians under education ordered most P-Ca analyses (OR 1.69 [1.35-2.24] and locum least (OR 0.73 [0.57-0.94]. More of the variance was attributed to the physician level than the HCC level. Different mix of patients did not explain this variance between physicians. Theoretically, if a patient were able to change both GP and HCC, the odds of a P-Ca analysis would in median increase by 2.45. Including characteristics of the patients, physicians and HCCs in the MLRA model did not explain the variance. Conclusions The physician level was more important than the HCC level for the variation in P-Ca analysis, but further exploration of unidentified contextual factors is crucial for future monitoring of practice variation.

  8. All Plasma Products Are Not Created Equal: Characterizing Differences Between Plasma Products

    Science.gov (United States)

    2015-06-01

    Research and the US Department of Defense. The pooling and solvent detergent treatment processes performed to manufacture the Octaplas and Kedrion products ...All plasma products are not created equal: Characterizing differences between plasma products Philip C. Spinella, MD, Elfaridah Frazier, PhD, Heather... products that may affect efficacy and safety. METHODS: Four different plasma products were analyzed to include fresh frozen plasma (FFP), liquid plasma

  9. Weakly nonlinear electron plasma waves in collisional plasmas

    DEFF Research Database (Denmark)

    Pecseli, H. L.; Rasmussen, J. Juul; Tagare, S. G.

    1986-01-01

    The nonlinear evolution of a high frequency plasma wave in a weakly magnetized, collisional plasma is considered. In addition to the ponderomotive-force-nonlinearity the nonlinearity due to the heating of the electrons is taken into account. A set of nonlinear equations including the effect...

  10. Spectroscopic Investigation of Nitrogen Loaded ECR Plasmas

    CERN Document Server

    Ullmann, F; Zschornack, G; Küchler, D; Ovsyannikov, V P

    1999-01-01

    Energy dispersive X-ray spectroscopy on ions in the plasma and magnetic q/A-analysis of the extracted ions were used to determine the plasmaproperties of nitrogen loaded ECR plasmas.As the beam expands from a limited plasma region and the ion extraction process alters the plasma properties in the extraction meniscus thebeam composition does not correspond to the bulk plasma composition. The analysis of measured spectra of characteristic X-rays delivers a method to determine the ion charge state distribution and the electron energy distribution inside the plasma and does not alter the plasma anddoes not depend on the extraction and transmission properties of the ion extraction and transport system. Hence this method seems to be moreaccurate than the traditional magnetic analysis and allows to analyse different plasma regions.A comparison between ion charge state distributions determined from X-ray spectra and such from q/A-analysis shows significant differencesfor the mean ion charge states in the source plasm...

  11. Theoretical modeling of transport barriers in helical plasmas

    International Nuclear Information System (INIS)

    Toda, S.; Itoh, K.; Ohyabu, N.

    2008-10-01

    A unified transport modelling to explain electron Internal Transport Barriers (e-ITB) in helical plasmas and Internal Diffusion Barriers (IDB) observed in Large Helical Device (LHD) is proposed. The e-ITB can be predicted with the effect of zonal flows to obtain the e-ITB in the low collisional regime when the radial variation of the particle anomalous diffusivity is included. Transport analysis in this article can newly show that the particle fuelling induces the IDB formation when this unified transport modelling is used in the high collisional regime. The density limit for the IDB in helical plasmas is also examined including the effect of the radiation loss. (author)

  12. Safety analyses for transient behavior of plasma and in-vessel components during plasma abnormal events in fusion reactor

    International Nuclear Information System (INIS)

    Honda, Takuro; Okazaki, Takashi; Bartels, H.W.; Uckan, N.A.; Seki, Yasushi.

    1997-01-01

    Safety analyses on plasma abnormal events have been performed using a hybrid code of a plasma dynamics model and a heat transfer model of in-vessel components. Several abnormal events, e.g., increase in fueling rate, were selected for the International Thermonuclear Experimental Reactor (ITER) and transient behavior of the plasma and the invessel components during the events was analyzed. The physics model for safety analysis was conservatively prepared. In most cases, the plasma is terminated by a disruption or it returns to the original operation point. When the energy confinement improves by a factor of 2.0 in the steady state, which is a hypothetical assumption under the present plasma data, the maximum fusion power reaches about 3.3 GW at about 3.6 s and the plasma is terminated due to a disruption. However, the results obtained in this study show the confinement boundary of ITER can be kept almost intact during the abnormal plasma transients, as long as the cooling system works normally. Several parametric studies are needed to comprehend the overpower transient including structure behavior, since many uncertainties are connected to the filed of the plasma physics. And, future work will need to discuss the burn control scenario considering confinement mode transition, system specifications, experimental plans and safety regulations, etc. to confirm the safety related to the plasma anomaly. (author)

  13. ICRF heating analysis on ASDEX plasmas

    International Nuclear Information System (INIS)

    Itoh, Sanae; Itoh, Kimitaka; Fukuyama, Atsushi; Morishita, Takayuki; Steinmetz, K.; Noterdaeme, J.-M.

    1988-01-01

    ICRF (ion cyclotron range of frequencies) waves heating in an ASDEX tokamak are analyzed. The excitation, propagation and absorption are studied by using a global wave code. This analysis is combined with a Fokker-Planck code. The waveform in the plasma, the loading resistance and the reactance of the antenna are calculated for both the minority ion heating and the second harmonic resonance heating. Attention is given to the change of the antenna loading associated with the L/H transition. Optimum conditions for the loading are discussed. In the minority heating case, the tail generation and thermalization are analyzed. Spatial profiles of the tail-ion temperature and the power transferred to the bulk electrons and ions are obtained. Central as well as off-central heating cases are investigated. The effect of the reactive electric field is discussed in connection with rf losses and impurity production. (author)

  14. Preliminary Hazards Analysis Plasma Hearth Process

    International Nuclear Information System (INIS)

    Aycock, M.; Coordes, D.; Russell, J.; TenBrook, W.; Yimbo, P.

    1993-11-01

    This Preliminary Hazards Analysis (PHA) for the Plasma Hearth Process (PHP) follows the requirements of United States Department of Energy (DOE) Order 5480.23 (DOE, 1992a), DOE Order 5480.21 (DOE, 1991d), DOE Order 5480.22 (DOE, 1992c), DOE Order 5481.1B (DOE, 1986), and the guidance provided in DOE Standards DOE-STD-1027-92 (DOE, 1992b). Consideration is given to ft proposed regulations published as 10 CFR 830 (DOE, 1993) and DOE Safety Guide SG 830.110 (DOE, 1992b). The purpose of performing a PRA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PRA then is followed by a Preliminary Safety Analysis Report (PSAR) performed during Title I and II design. This PSAR then leads to performance of the Final Safety Analysis Report performed during construction, testing, and acceptance and completed before routine operation. Radiological assessments indicate that a PHP facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous material assessments indicate that a PHP facility will be a Low Hazard facility having no significant impacts either onsite or offsite to personnel and the environment

  15. Analysis of the plasma magnetohydrodynamic equilibrium in iron core transformer Tokamak HL-1M

    International Nuclear Information System (INIS)

    Chen Xiaoguang; Yuan Baoshan

    1992-01-01

    The physical and mathematical model are presented on the problem of MHD equilibrium with the self consistent in iron core transformer HL-1M. Calculation and analysis for the plasma equilibrium of the stable boundary and free boundary are shown respectively, in an axisymmetric equilibrium model of two dimensions. First, a variation formulation of the problem is written and the equations of the poloided flux ψ are solved by a finite element method; the Picard and Newton algorithms are tested for the non-linearities. The plasma boundary and the magnetic surfaces are being simulated, with the currents in the coils, the total plasma current, its current density function and the magnetic permeability of the iron being the data for the problem; a certain number of the characteristic parameter of the equilibrium configuration is calculated. Secondly, a simple method of calculation is adopted in the determination of equilibrium fields and currents in iron core HL-1M tokamak device. In the plasma equilibrium, the magnetic effect of the air gaps in the iron core and the iron magnetic shielded plate are considered in HL-1M device. Reliable data are provided for designing and constructing the poloidal field system of HL-1M device. A good computer code is constructed, which may be useful in operating on analysis for the future device

  16. Feature-Based Analysis of Plasma-Based Particle Acceleration Data

    Energy Technology Data Exchange (ETDEWEB)

    Rubel, Oliver [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Geddes, Cameron G. R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chen, Min [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cormier-Michel, Estelle [Tech-X Corp., Boulder, CO (United States); Bethel, E. Wes [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-02-01

    Plasma-based particle accelerators can produce and sustain thousands of times stronger acceleration fields than conventional particle accelerators, providing a potential solution to the problem of the growing size and cost of conventional particle accelerators. To facilitate scientific knowledge discovery from the ever growing collections of accelerator simulation data generated by accelerator physicists to investigate next-generation plasma-based particle accelerator designs, we describe a novel approach for automatic detection and classification of particle beams and beam substructures due to temporal differences in the acceleration process, here called acceleration features. The automatic feature detection in combination with a novel visualization tool for fast, intuitive, query-based exploration of acceleration features enables an effective top-down data exploration process, starting from a high-level, feature-based view down to the level of individual particles. We describe the application of our analysis in practice to analyze simulations of single pulse and dual and triple colliding pulse accelerator designs, and to study the formation and evolution of particle beams, to compare substructures of a beam and to investigate transverse particle loss.

  17. Plasma metabolic profiling analysis of nephrotoxicity induced by acyclovir using metabonomics coupled with multivariate data analysis.

    Science.gov (United States)

    Zhang, Xiuxiu; Li, Yubo; Zhou, Huifang; Fan, Simiao; Zhang, Zhenzhu; Wang, Lei; Zhang, Yanjun

    2014-08-01

    Acyclovir (ACV) is an antiviral agent. However, its use is limited by adverse side effect, particularly by its nephrotoxicity. Metabonomics technology can provide essential information on the metabolic profiles of biofluids and organs upon drug administration. Therefore, in this study, mass spectrometry-based metabonomics coupled with multivariate data analysis was used to identify the plasma metabolites and metabolic pathways related to nephrotoxicity caused by intraperitoneal injection of low (50mg/kg) and high (100mg/kg) doses of acyclovir. Sixteen biomarkers were identified by metabonomics and nephrotoxicity results revealed the dose-dependent effect of acyclovir on kidney tissues. The present study showed that the top four metabolic pathways interrupted by acyclovir included the metabolisms of arachidonic acid, tryptophan, arginine and proline, and glycerophospholipid. This research proves the established metabonomic approach can provide information on changes in metabolites and metabolic pathways, which can be applied to in-depth research on the mechanism of acyclovir-induced kidney injury. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Fundamental atomic plasma chemistry for semiconductor manufacturing process analysis

    International Nuclear Information System (INIS)

    Ventzek, P.L.G.; Zhang, D.; Stout, P.J.; Rauf, S.; Orlowski, M.; Kudrya, V.; Astapenko, V.; Eletskii, A.

    2002-01-01

    An absence of fundamental atomic plasma chemistry data (e.g. electron impact cross-sections) hinders the application of plasma process models in semiconductor manufacturing. Of particular importance is excited state plasma chemistry data for metallization applications. This paper describes important plasma chemistry processes in the context of high density plasmas for metallization application and methods for the calculation of data for the study of these processes. Also discussed is the development of model data sets that address computational tractability issues. Examples of model electron impact cross-sections for Ni reduced from multiple collision processes are presented

  19. Analysis of equilibrium and topology of tokamak plasmas

    International Nuclear Information System (INIS)

    Milligen, B.P. van.

    1991-01-01

    In a tokamak, the plasma is confined by means of a magnetic field. There exists an equilibrium between outward forces due to the pressure gradient in plasma and inward forces due to the interaction between currents flowing inside the plasma and the magnetic field. The equilibrium magnetic field is characterized by helical field lines that lie on nested toroidal surfaces of constant flux. The equilibrium yields values for global and local plasma parameters (e.g. plasma position, total current, local pressure). Thus, precise knowledge of the equilibrium is essential for plasma control, for the understanding of many phenomena occurring in the plasma (in particular departures from the ideal equilibrium involving current filamentation on the flux surfaces that lead to the formation of islands, i.e. nested helical flux surfaces), and for the interpretation of many different types of measurements (e.g. the translation of line integrated electron density measurements made by laser beams probing the plasma into a local electron density on a flux surface). The problem of determining the equilibrium magnetic field from external magnetic field measurements has been studied extensively in literature. The problem is 'ill-posed', which means that the solution is unstable to small changes in the measurement data, and the solution has to be constrained in order to stabilize it. Various techniques for handling this problem have been suggested in literature. Usually ad-hoc restrictions are imposed on the equilibrium solution in order to stabilize it. More equilibrium solvers are not able to handle very dissimilar measurement data which means information on the equilibrium is lost. The generally do not allow a straightforward error estimate of the obtained results to be made, and they require large amounts of computing time. This problems are addressed in this thesis. (author). 104 refs.; 42 figs.; 6 tabs

  20. Qualitative analysis of plasma created by shock laser

    International Nuclear Information System (INIS)

    Grevey, D.; Maiffredy, L.; Vannes, A.B.; Gobin, P.F.

    1987-01-01

    The origin of effects observed of the surface of metals treated by lasers was studied. High speed cinematography (20,000 frames/sec) was used to follow the evolution of plasma shape from start to finish. An Nd glass laser and FeNi targets were used. The irradiated surface was examined using optical and scanning electron-microscopes. The phenomenology of plasma formation, and plasma expansion are summarized. Liquid spattering and concentric waves on the target surface are revealed. Results suggest that the main agent of the effects in laser-target interactions is the plasma, which creates compression waves inside the target. These waves quickly become a shock wave which can modify the microstructure of the target [fr

  1. Stochastic resonance is applied to quantitative analysis for weak chromatographic signal of glyburide in plasma

    International Nuclear Information System (INIS)

    Zhang Wei; Xiang Bingren; Wu Yanwei; Shang Erxin

    2005-01-01

    Based on the theory of stochastic resonance, a new method carried on the quantitive analysis to weak chromatographic signal of glyburide in plasma, which was embedded in the noise background and the signal-to-noise ratio (SNR) of HPLC-UV is enhanced remarkably. This method enhances the quantification limit to 1 ng ml -1 , which is the same as HPLC-MS, and makes it possible to detect the weak signal accurately by HPLC-UV, which was not suitable before. The results showed good recovery and linear range from 1 to 50 ng ml -1 of glyburide in plasma and the method can be used for quantitative analysis of glyburide

  2. First trimesters Pregnancy-Associated Plasma Protein-A levels value to Predict Gestational diabetes Mellitus: A systematic review and meta-analysis of the literature

    Directory of Open Access Journals (Sweden)

    Zahra Hadizadeh Talasaz

    2018-04-01

    Full Text Available Detecting pregnant women at risk of diabetes in first months can help them by early intervention for delaying or preventing onset of GDM. In this study, we aimed to assess the Predictive value of first trimester Pregnancy related plasma protein-A (PAPP-A levels for detecting Gestational diabetes Mellitus (GDM. This systematic review and meta-analysis was conducted through probing in databases. PubMed, Scopus, Medline and Google scholar citations were searched to find the published papers from 1974 to 2017. Studies were considered eligible if they were cohorts, case–control studies, reported GDM result, not other types, conducted on singleton pregnancy, measured Serum pregnancy associated plasma protein A in the first trimester and evaluated the relation of first trimester pregnancy associated plasma protein–A and GDM. Two reviewers independently assessed the quality with Newcastle–Ottawa and extracted data in the Pre-defined checklist. Analysis of the data was carried out by “Comprehensive Meta-analysis Version 2 (CAM” and Metadisc software. 17 articles have our inclusion criteria and were considered in our systematic review, 5 studies included in Meta-analysis. Meta-analysis of these articles showed that the predictive value of PAPP-A for GDM has 55% sensitivity (53–58, 90% (89–90 specificity, LR + 2.48 (0.83–7.36 and LR − 0.70 (0.45–1.09 with 95% confidence intervals. In our study PAPP-A has low predictive accuracy overall, but it may be useful when combined with other tests, and this is an active part for future research. One limitation of our study is significant heterogeneity because of different adjusted variables and varied diagnostic criteria. Keywords: Gestational diabetes Mellitus, Pregnancy-Associated Plasma Protein-A, First trimesters, Systematic review

  3. 2D statistical analysis of Non-Diffusive transport under attached and detached plasma conditions of the linear divertor simulator

    International Nuclear Information System (INIS)

    Tanaka, H.; Ohno, N.; Tsuji, Y.; Kajita, S.

    2010-01-01

    We have analyzed the 2D convective motion of coherent structures, which is associated with plasma blobs, under attached and detached plasma conditions of a linear divertor simulator, NAGDIS-II. Data analysis of probes and a fast-imaging camera by spatio-temporal correlation with three decomposition and proper orthogonal decomposition (POD) was carried out to determine the basic properties of coherent structures detached from a bulk plasma column. Under the attached plasma condition, the spatio-temporal correlation with three decomposition based on the probe measurement showed that two types of coherent structures with different sizes detached from the bulk plasma and the azimuthally localized structure radially propagated faster than the larger structure. Under the detached plasma condition, movies taken by the fast-imaging camera clearly showed the dynamics of a 2D spiral structure at peripheral regions of the bulk plasma; this dynamics caused the broadening of the plasma profile. The POD method was used for the data processing of the movies to obtain low-dimensional mode shapes. It was found that the m=1 and m=2 ring-shaped coherent structures were dominant. Comparison between the POD analysis of both the movie and the probe data suggested that the coherent structure could be detached from the bulk plasma mainly associated with the m=2 fluctuation. This phenomena could play an important role in the reduction of the particle and heat flux as well as the plasma recombination processes in plasma detachment (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. An Analysis of Unseasonal Equatorial Plasma Bubbles in July 2014

    Science.gov (United States)

    Carter, B. A.; Currie, J. L.; Pradipta, R.; Groves, K. M.; Caton, R. G.; Yokoyama, T.

    2017-12-01

    In the equatorial ionosphere, the Raleigh-Taylor (RT) plasma instability in the post sunset region is known to cause plasma depletions, known as equatorial plasma bubbles (EPBs). These EPBs can have adverse effects on satellite-reliant technologies by causing scintillations in the phase and amplitude of Global Navigation Satellite System (GNSS) signals. The effect of EPBs on satellite-reliant technologies highlights a need for reliable forecasting of EPBs in the low-latitude regions, which requires a solid understanding of their climatology and daily variability. The climatology of EPB occurrence is known to correlate with the angle between the magnetic field and solar terminator. This angle controls the longitudinal E-region conductivity gradient across the day-night terminator, which influences the strength of the pre-reversal enhancement in the upward plasma drift, a dominant term in the linear RT growth rate. This relationship is well established from ground-based GNSS and satellite-based studies. However, reliable forecasts have not been developed by space weather forecasting agencies due to the lack of understanding of EPB daily variability. During July, EPB occurrence is small in the South-East Asia longitude sector due to the relatively large angle between the magnetic field and solar terminator. As a result, the pre-reversal enhancement in the upward plasma drift is typically low during this period, creating less favourable conditions for EPB growth. However, despite the typically low pre-reversal enhancement strength, this analysis reveals that July 2014 is not devoid of EPB events above South-East Asia. These unseasonal EPB events during July 2014 are studied in the context of the prevalently low solar and geomagnetic activity conditions. Given the lack of solar and geomagnetic control, the influence of the lower atmosphere on EPB generation (e.g., via atmospheric gravity wave seeding) is explored. These events provide a unique opportunity to investigate

  5. Analysis of organic pollutant degradation in pulsed plasma by coherent anti-Stokes Raman spectroscopy

    International Nuclear Information System (INIS)

    Bratescu, Maria Antoneta; Hieda, Junko; Umemura, Tomonari; Saito, Nagahiro; Takai, Osamu

    2011-01-01

    The degradation of p-benzoquinone (p-BQ) in water was investigated by the coherent anti-Stokes Raman spectroscopy (CARS) method, in which the change of the anti-Stokes signal intensity corresponding to the vibrational transitions of the molecule is monitored during and after solution plasma processing (SPP). In the beginning of SPP treatment, the CARS signal intensity of the ring vibrational molecular transitions at 1233 and 1660 cm -1 increases under the influence of the electric field of the plasma, depending on the delay time between the plasma pulse and the laser firing pulse. At the same time, the plasma contributes to the degradation of p-BQ molecules by generating hydrogen and hydroxyl radicals, which decompose p-BQ into different carboxylic acids. After SPP, the CARS signal intensity of the vibrational bands of p-BQ ceased and the degradation of p-BQ was confirmed by UV-visible absorption spectroscopy and liquid chromatography analysis.

  6. Finite element analysis of residual stress in plasma-sprayed ceramic

    International Nuclear Information System (INIS)

    Mullen, R.L.; Hendricks, R.C.; McDonald, G.

    1985-01-01

    Residual stress in a ZrO 2 -Y 2 O 3 ceramic coating resulting from the plasma spraying operation is calculated. The calculations were done using the finite element method. Both thermal and mechanical analysis were performed. The resulting residual stress field was compared to the measurements obtained by Hendricks and McDonald. Reasonable agreement between the predicted and measured moment occurred. However, the resulting stress field is not in pure bending

  7. Dynamics of Plasma-Surface Interactions using In-situ Ion Beam Analysis

    International Nuclear Information System (INIS)

    Whyte, D.G.

    2009-01-01

    The overall goal of this proposal was to develop an innovative experimental facility that would allow for the measurement of real-time response of a material surface to plasma bombardment by employing in-situ high-energy ion beam analysis. This facility was successfully developed and deployed at U. Wisconsin-Madison and was named DIONISOS (Dynamics of IONic Implantation and Sputtering on Surfaces). There were several major highlights to the DIONISOS research which we will briefly highlight below. The full technical details of the DIONISOS development, deployment and research results are contained in the Appendices which contain several peer-reviewed publications and a PhD thesis devoted to DIONISOS. The DIONISOS results on deuterium retention in molybdenum were chosen as an invited talk at the 2008 International Conference on Plasma-Surface Interactions in Toledo, Spain.

  8. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  9. Plasma waves

    National Research Council Canada - National Science Library

    Swanson, D. G

    1989-01-01

    ... Swanson, D.G. (Donald Gary), D a t e - Plasma waves. Bibliography: p. Includes index. 1. Plasma waves. QC718.5.W3S43 1989 ISBN 0-12-678955-X I. Title. 530.4'4 88-34388 Printed in the United Sta...

  10. Laser-aided diagnostics of plasmas and gases

    CERN Document Server

    Muraoka, K

    2000-01-01

    Updated and expanded from the original Japanese edition, Laser-Aided Diagnostics of Gases and Plasmas takes a unique approach in treating laser-aided diagnostics. The book unifies the subject by joining applications instead of describing each application as a totally separate system. In taking this approach, it highlights the relative strengths of each method and shows how they can complement each other in the study of gases and plasmas.The first part of the book presents a general introduction to the laser-aided study of gases and plasmas, including the various principles and hardware needed for each method, while the second part describes the applications of each general system in detail.Beneficial to a wide spectrum of academic and industrial researchers, this book provides a solid examination of the various options and methods available when involved in the analysis and diagnostics of gases and plasmas.

  11. Cosmic plasma

    Energy Technology Data Exchange (ETDEWEB)

    Alfven, H [California Univ., San Diego, La Jolla (USA)

    1981-01-01

    The properties of space plasmas are analyzed, based on laboratory results and data obtained by in situ measurements in the magnetosphere (including the heliosphere). Attention is given to the question of how much knowledge can be gained by a systematic comparison of different regions of plasma, and plasmas are considered with linear dimensions varying from laboratory size up to the Hubble distance. The traditional magnetic field description of plasmas is supplemented by an electric current description and it is demonstrated that many problems are easier to understand with a dualistic approach. Using the general plasma properties obtained, the origin and evolution of the solar system is summarized and the evolution and present structure of the universe (cosmology) is discussed.

  12. System analysis and test-bed for an atmosphere-breathing electric propulsion system using an inductive plasma thruster

    Science.gov (United States)

    Romano, F.; Massuti-Ballester, B.; Binder, T.; Herdrich, G.; Fasoulas, S.; Schönherr, T.

    2018-06-01

    Challenging space mission scenarios include those in low altitude orbits, where the atmosphere creates significant drag to the S/C and forces their orbit to an early decay. For drag compensation, propulsion systems are needed, requiring propellant to be carried on-board. An atmosphere-breathing electric propulsion system (ABEP) ingests the residual atmosphere particles through an intake and uses them as propellant for an electric thruster. Theoretically applicable to any planet with atmosphere, the system might allow to orbit for unlimited time without carrying propellant. A new range of altitudes for continuous operation would become accessible, enabling new scientific missions while reducing costs. Preliminary studies have shown that the collectible propellant flow for an ion thruster (in LEO) might not be enough, and that electrode erosion due to aggressive gases, such as atomic oxygen, will limit the thruster lifetime. In this paper an inductive plasma thruster (IPT) is considered for the ABEP system. The starting point is a small scale inductively heated plasma generator IPG6-S. These devices are electrodeless and have already shown high electric-to-thermal coupling efficiencies using O2 and CO2 . The system analysis is integrated with IPG6-S tests to assess mean mass-specific energies of the plasma plume and estimate exhaust velocities.

  13. Revisiting the analysis of passive plasma shutdown during an ex-vessel loss of coolant accident in ITER blanket

    International Nuclear Information System (INIS)

    Rivas, J.C.; Dies, J.; Fajarnés, X.

    2015-01-01

    Highlights: • We have repeated the safety analysis for the hypothesis of passive plasma shutdown for beryllium evaporation during an ex-vessel LOCA of ITER first wall, with AINA code. • We have performed a sensitivity analysis over some key parameters that represents uncertainties in physics and engineering, to identify cliff edge effects. • The obtained results for the 500 MW inductive scenario, with an ex-vessel LOCA affecting a third of first wall surface are similar to those of previous studies and point to the possibility of a passive plasma shutdown during this safety case, before a serious damage is inflicted to the ITER wall. • The sensitivity analysis revealed a new scenario potentially damaging for the first wall if we increase fusion power and time delay for impurity transport, and decrease fraction of affected first wall area and initial beryllium fraction in plasma. • After studying the 700 MW inductive scenario, with an ex-vessel LOCA affecting 10% of first wall surface, with 0.5% of Be in plasma and a time delay twice the energy confinement time, it was found that affected area of first wall would melt before a passive plasma shutdown occurs. - Abstract: In this contribution, the analysis of passive safety during an ex-vessel loss of coolant accident (LOCA) in the first wall/shield blanket of ITER has been studied with AINA safety code. In the past, this case has been studied using robust safety arguments, based on simple 0D models for plasma balance equations and 1D models for wall heat transfer. The conclusion was that, after first wall heating up due to the loss of all coolant, the beryllium evaporation in the wall surface would induce a growing impurity flux into core plasma that finally would end in a passive shut down of the discharge. The analysis of plasma-wall transients in this work is based in results from AINA code simulations. AINA (Analyses of IN vessel Accidents) code is a safety code developed at Fusion Energy Engineering

  14. Three-phase double-arc plasma for spectrochemical analysis of environmental samples.

    Science.gov (United States)

    Mohamed, M M; Ghatass, Z F; Shalaby, E A; Kotb, M M; El-Raey, M

    2000-12-01

    A new instrument, which uses a three-phase current to support a double-arc argon plasma torch for evaporation, atomization and excitation of solid or powder samples, is described. The sampling arc is ignited between the first and second electrode while the excitation arc is ignited between the second and third electrode. Aerosol generated from the sample (first electrode) is swept by argon gas, through a hole in the second electrode (carbon tubing electrode), into the excitation plasma. A tangential stream of argon gas is introduced through an inlet orifice as a coolant gas for the second electrode. This gas stream forces the excitation arc discharge to rotate reproducibly around the electrode surface. Discharge rotation increases the stability of the excitation plasma. Spectroscopic measurements are made directly in the current-carrying region of the excitation arc. An evaluation of each parameter influencing the device performance was performed. Analytical calibration curves were obtained for Fe, Al, K, and Pb. Finally, the present technique was applied for the analysis of environmental samples. The present method appears to have significant, low cost analytical utility for environmental measurements.

  15. Analysis of time- and space-resolved Na-, Ne-, and F-like emission from a laser-produced bromine plasma

    International Nuclear Information System (INIS)

    Goldstein, W.H.; Young, B.K.F.; Osterheld, A.L.; Stewart, R.E.; Walling, R.S.; Bar-Shalom, A.

    1991-01-01

    Advances in the efficiency and accuracy of computational atomic physics and collisional radiative modeling promise to place the analysis and diagnostic application of L-shell emission on a par with the simpler K-shell regime. Coincident improvements in spectroscopic plasma measurements yield optically thin emission spectra from small, homogeneous regions of plasma, localized both in space and time. Together, these developments can severely test models for high-density, high-temperature plasma formation and evolution, and non-LTE atomic kinetics. In this paper we present highly resolved measurements of n=3 to n=2 X-ray line emission from a laser-produced bromine micro plasma. The emission is both space- and time-resolved, allowing us to apply simple, steady-state, 0-dimensional spectroscopic models to the analysis. These relativistic, multi-configurational, distorted wave collisional-radiative models were created using the HULLAC atomic physics package. Using these models, we have analyzed the F-like, Ne-like and Na-like (satellite) spectra with respect to temperature, density and charge-state distribution. This procedure leads to a full characterization of the plasma conditions. 9 refs., 3 figs

  16. A Rapid, Simple, and Validated RP-HPLC Method for Quantitative Analysis of Levofloxacin in Human Plasma

    Directory of Open Access Journals (Sweden)

    Dion Notario

    2017-04-01

    Full Text Available To conduct a bioequivalence study for a copy product of levofloxacin (LEV, a simple and validated analytical method was needed, but the previous developed methods were still too complicated. For this reason, a simple and rapid high performance liquid chromatography method was developed and validated for LEV quantification in human plasma. Chromatographic separation was performed under isocratic elution on a Luna Phenomenex® C18 (150 × 4.6 mm, 5 µm column. The mobile phase was comprised of acetonitrile, methanol, and phosphate buffer 25 mM that adjusted at pH 3.0 (13:7:80 v/v/v and pumped at a flow rate of 1.5 mL/min. Detection was performed under UV detector at wavelength of 280 nm. Samples were prepared by adding acetonitrile and followed by centrifugation to precipitate plasma protein. Then followed successively by evaporation and reconstitution step. The optimized method meets the requirements of validation parameters which included linearity (r = 0.995, sensitivity (LLOQ and LOD was 1.77 and 0.57 µg/mL respectively, accuracy (%error above LLOQ ≤ 12% and LLOQ ≤ 20%, precision (RSD ≤ 9%, and robustness in the ranges of 1.77-28.83 µg/mL. Therefore, the method can be used as a routine analysis of LEV in human plasma as well as in bioequivalence study of LEV.

  17. Design and analysis considerations in the Ebola_Tx trial evaluating convalescent plasma in the treatment of Ebola virus disease in Guinea during the 2014-2015 outbreak.

    Science.gov (United States)

    Edwards, Tansy; Semple, Malcolm G; De Weggheleire, Anja; Claeys, Yves; De Crop, Maaike; Menten, Joris; Ravinetto, Raffaella; Temmerman, Sarah; Lynen, Lutgarde; Bah, Elhadj Ibrahima; Smith, Peter G; van Griensven, Johan

    2016-02-01

    The Ebola virus disease outbreak in 2014-2015 led to a huge caseload with a high case fatality rate. No specific treatments were available beyond supportive care for conditions such as dehydration and shock. Evaluation of treatment with convalescent plasma from Ebola survivors was identified as a priority. We evaluated this intervention in an emergency setting, where randomization was unacceptable. The original trial design was an open-label study comparing patients receiving convalescent plasma and supportive care to patients receiving supportive care alone. The comparison group comprised patients recruited at the start of the trial before convalescent plasma became available, as well as patients presenting during the trial for whom there was insufficient blood group-compatible plasma or no staffing capacity to provide additional transfusions. However, during the trial, convalescent plasma was available to treat all new patients. The design was changed to use a comparator group comprising patients previously treated at the same Ebola treatment center prior to the start of the trial. In the analysis, it was planned to adjust for any differences in prognostic variables between intervention and comparison groups, specifically baseline polymerase chain reaction cycle threshold and age. In addition, adjustment was planned for other potential confounders, identified in the analysis, such as patient presenting symptoms and time to treatment seeking. Because plasma treatment started up to 3 days after diagnosis and we could not define a similar time-point for the comparator group, patients who died before the third day after confirmation of diagnosis were excluded from both intervention and comparison groups in a per-protocol analysis. Some patients received additional experimental treatments soon after plasma treatment, and these were excluded. We also analyzed mortality including all patients from the time of confirmed diagnosis, irrespective of whether those in the

  18. Electromagnetic analysis of ITER generic equatorial port plug designs during three plasma current disruption cases

    International Nuclear Information System (INIS)

    Guirao, J.; Rodríguez, E.; Ordieres, J.; Cabanas, M.F.; García, C.H. Rojas

    2012-01-01

    Highlights: ► Electromagnetic transient performance evaluation of the GEPP structure. ► Three different plasma current disruption cases: MD UP LIN36, VDE UP LIN36 and VDE DW LIN36 were analyzed. ► Three DSM-First Wall (FW) designs (horizontal and vertical drawers and monoblock) were compared. - Abstract: Electromagnetic phenomena due to plasma current disruptions are the cause for the main mechanical operation loads over the ITER equatorial level port plug structures. This paper presents a detailed finite element simulation and analysis of the transient electromagnetic effects of three different plasma current disruption cases over three designs of diagnostic shielding module (DSM) structure. The DSMs are contained into and supported by the generic equatorial port plug (GEPP) analyzed structure. The three plasma disruption cases studied were: major disruption upwards linear decay in 36 ms (MD UP LIN36), vertical displacements events, upwards and downwards linear decay in 36 ms (VDE UP LIN36 and VDE DW LIN36). A detailed analysis for GEPP structure and three DSM-first wall (FW) designs (horizontal and vertical drawers and monoblock) is also presented in order to extract the Eddy current distribution on these devices and thus the resultant electromagnetic forces and moments acting on them.

  19. Analysis of hysteresis characteristics and low frequency oscillation in gas discharge plasma

    International Nuclear Information System (INIS)

    Matsunaga, Yasushi; Kato, Tomokazu

    1997-01-01

    Hysteresis of gas discharge plasma and nonlinear oscillation of low frequency, caused by the trapped ion, are analyzed. Mainly, the hysteresis and emergence of multiple-steady states are discussed by a simple model of chemical-reaction system. It is shown that a function describing the energy balance has three different real roots. The condition for plural roots depends on the ratio of the bulk energy increase to the surface energy loss of plasma. The criterion contains the non-thermodynamic variables such as conductivity and surface quantities. Examination of stabilities of three-obtained solutions by using linear analysis of differential equations manifests that a root represents a saddle point and other two roots represent stable points. (author)

  20. Analysis of the results obtained by optical measurements in plasma focus equipments

    International Nuclear Information System (INIS)

    Bilbao, L.; Bruzzone, H.

    1982-01-01

    The results obtained by shadow and Schlieren photographies and interferometry in a 1MJ plasma focus device of Frascati (CNEN-EURATOM, Italy) are compared with a great number of similar measurement results in several devices of the world. A critical analysis of the above results is presented. (L.C.) [pt

  1. Streaming metal plasma generation by vacuum arc plasma guns

    International Nuclear Information System (INIS)

    MacGill, R.A.; Dickinson, M.R.; Anders, A.; Monteiro, O.R.; Brown, I.G.

    1998-01-01

    We have developed several different embodiments of repetitively pulsed vacuum arc metal plasma gun, including miniature versions, multicathode versions that can produce up to 18 different metal plasma species between which one can switch, and a compact high-duty cycle well-cooled version, as well as a larger dc gun. Plasma guns of this kind can be incorporated into a vacuum arc ion source for the production of high-energy metal ion beams, or used as a plasma source for thin film formation and for metal plasma immersion ion implantation and deposition. The source can also be viewed as a low-energy metal ion source with ion drift velocity in the range 20 - 200 eV depending on the metal species used. Here we describe the plasma sources that we have developed, the properties of the plasma generated, and summarize their performance and limitations. copyright 1998 American Institute of Physics

  2. Scaling laws for TEXT plasma profiles

    International Nuclear Information System (INIS)

    McCool, S.C.; Bravenec, R.V.; Chen, J.Y.; Foster, M.S.; Li, W.L.; Ouroura, A.; Phillips, P.E.; Richards, B.; Wenzel, K.W.; Zhang, Z.M.

    1994-01-01

    Regression analysis has been performed on a number of measured profiles including temperature and density vs. nominal macroscopic operating parameters for TEXT tokamak (pre-upgrade) ohmic plasmas. The resulting simple empirical model has enabled the authors to quickly approximate profiles of electron temperature and density, ion temperature, and soft x-ray brightness, as well as the scalar quantities: total radiated power, q=1 radius, sawtooth period and amplitude, and energy confinement time as a power law of toroidal field, plasma current, chord average density, and fueling gas atomic weight. The model profiles are only applicable to the plasma interior, i.e. within the limiter radius. In most cases the predicted model profiles are within the experimental error bars of measured profiles and are more accurate at predicting profile variation for small operating parameter changes than the measured profiles

  3. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  4. Post hoc analysis of plasma amino acid profiles: towards a specific pattern in autism spectrum disorder and intellectual disability.

    Science.gov (United States)

    Delaye, Jean-Baptiste; Patin, Franck; Lagrue, Emmanuelle; Le Tilly, Olivier; Bruno, Clement; Vuillaume, Marie-Laure; Raynaud, Martine; Benz-De Bretagne, Isabelle; Laumonnier, Frederic; Vourc'h, Patrick; Andres, Christian; Blasco, Helene

    2018-01-01

    Objectives Autism spectrum disorders and intellectual disability present a challenge for therapeutic and dietary management. We performed a re-analysis of plasma amino acid chromatography of children with autism spectrum disorders ( n = 22) or intellectual disability ( n = 29) to search for a metabolic signature that can distinguish individuals with these disorders from controls ( n = 30). Methods We performed univariate and multivariate analyses using different machine learning strategies, from the raw data of the amino acid chromatography. Finally, we analysed the metabolic pathways associated with discriminant biomarkers. Results Multivariate analysis revealed models to discriminate patients with autism spectrum disorders or intellectual disability and controls from plasma amino acid profiles ( P intellectual disability patients shared similar differences relative to controls, including lower glutamate ( P intellectual disability revealed the involvement of urea, 3-methyl-histidine and histidine metabolism. Biosigner analysis and univariate analysis confirmed the role of 3-methylhistidine ( P = 0.004), histidine ( P = 0.003), urea ( P = 0.0006) and lysine ( P = 0.002). Conclusions We revealed discriminant metabolic patterns between autism spectrum disorders, intellectual disability and controls. Amino acids known to play a role in neurotransmission were discriminant in the models comparing autism spectrum disorders or intellectual disability to controls, and histidine and b-alanine metabolism was specifically highlighted in the model.

  5. Revisiting the plasma sheath—dust in plasma sheath

    Energy Technology Data Exchange (ETDEWEB)

    Das, G. C. [Mathematical Science Division, IASST, Guwahati 781014 (India); Deka, R.; Bora, M. P., E-mail: mpbora@gauhati.ac.in [Physics Department, Gauhati University, Guwahati 781014 (India)

    2016-04-15

    In this work, we have considered the formation of warm plasma sheath in the vicinity of a wall in a plasma with considerable presence of dust particles. As an example, we have used the parameters relevant in case of plasma sheath formed around surfaces of various solid bodies in space, though the results obtained in this work can be applied to any other physical situation such as laboratory plasma. In the ion-acoustic time scale, we neglect the dust dynamics. The dust particles affect the sheath dynamics by affecting the Poisson equation which determines the plasma potential in the sheath region. It is important to note that our calculations are valid only when the amount of dust particles is not sufficient so as to affect the plasma dynamics in the dust-acoustic time scale, but enough to affect the plasma sheath. We have assumed the current to a dust particle to be balanced throughout the analysis. This makes the grain potential dependent on plasma potential, which is then incorporated into the Poisson equation. The resultant numerical model becomes an initial value problem, which is described by a 1-D integro-differential equation, which is then solved self-consistently by incorporating the change in plasma potential caused by inclusion of the dust potential in the Poisson equation.

  6. Capillary plasma jet: A low volume plasma source for life science applications

    Energy Technology Data Exchange (ETDEWEB)

    Topala, I., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Alexandru Ioan Cuza University of Iasi, Faculty of Physics, Iasi Plasma Advanced Research Center (IPARC), Bd. Carol I No. 11, Iasi 700506 (Romania); Nagatsu, M., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-02-02

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  7. Capillary plasma jet: A low volume plasma source for life science applications

    Science.gov (United States)

    Topala, I.; Nagatsu, M.

    2015-02-01

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  8. Plasmas for medicine

    Science.gov (United States)

    von Woedtke, Th.; Reuter, S.; Masur, K.; Weltmann, K.-D.

    2013-09-01

    Plasma medicine is an innovative and emerging field combining plasma physics, life science and clinical medicine. In a more general perspective, medical application of physical plasma can be subdivided into two principal approaches. (i) “Indirect” use of plasma-based or plasma-supplemented techniques to treat surfaces, materials or devices to realize specific qualities for subsequent special medical applications, and (ii) application of physical plasma on or in the human (or animal) body to realize therapeutic effects based on direct interaction of plasma with living tissue. The field of plasma applications for the treatment of medical materials or devices is intensively researched and partially well established for several years. However, plasma medicine in the sense of its actual definition as a new field of research focuses on the use of plasma technology in the treatment of living cells, tissues, and organs. Therefore, the aim of the new research field of plasma medicine is the exploitation of a much more differentiated interaction of specific plasma components with specific structural as well as functional elements or functionalities of living cells. This interaction can possibly lead either to stimulation or inhibition of cellular function and be finally used for therapeutic purposes. During recent years a broad spectrum of different plasma sources with various names dedicated for biomedical applications has been reported. So far, research activities were mainly focused on barrier discharges and plasma jets working at atmospheric pressure. Most efforts to realize plasma application directly on or in the human (or animal) body for medical purposes is concentrated on the broad field of dermatology including wound healing, but also includes cancer treatment, endoscopy, or dentistry. Despite the fact that the field of plasma medicine is very young and until now mostly in an empirical stage of development yet, there are first indicators of its enormous

  9. Ion Beam Analysis applied to laser-generated plasmas

    Czech Academy of Sciences Publication Activity Database

    Cutroneo, Mariapompea; Macková, Anna; Havránek, Vladimír; Malinský, Petr; Torrisi, L.; Kormunda, M.; Barchuk, M.; Ullschmied, Jiří; Dudžák, Roman

    2016-01-01

    Roč. 11, APR (2016), C04011 ISSN 1748-0221. [Conference on Plasma Physics by Laser and Applications (PPLA). Frascati, 05.10.2015-07.10.2015] R&D Projects: GA MŠk(CZ) LM2011019; GA ČR GA15-01602S; GA MŠk LM2015073 Institutional support: RVO:61389021 ; RVO:61389005 Keywords : accelerator applications * lasers * plasma diagnostics Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders; BL - Plasma and Gas Discharge Physics (UFP-V) Impact factor: 1.220, year: 2016

  10. Spacecraft-plasma-debris interaction in an ion beam shepherd mission

    Science.gov (United States)

    Cichocki, Filippo; Merino, Mario; Ahedo, Eduardo

    2018-05-01

    This paper presents a study of the interaction between a spacecraft, a plasma thruster plume and a free floating object, in the context of an active space debris removal mission based on the ion beam shepherd concept. The analysis is performed with the EP2PLUS hybrid code and includes the evaluation of the transferred force and torque to the target debris, its surface sputtering due to the impinging hypersonic ions, and the equivalent electric circuit of the spacecraft-plasma-debris interaction. The electric potential difference that builds up between the spacecraft and the debris, the ion backscattering and the backsputtering contamination of the shepherd satellite are evaluated for a nominal scenario. A sensitivity analysis is carried out to evaluate quantitatively the effects of electron thermodynamics, ambient plasma, heavy species collisions, and debris position.

  11. Plasma proteome analysis of patients with type 1 diabetes with diabetic nephropathy

    DEFF Research Database (Denmark)

    Overgaard, Anne Julie; Hansen, Henning Gram; Lajer, Maria

    2010-01-01

    patients was investigated with the goal of finding improved candidate biomarkers to predict diabetic nephropathy. In order to reach lower concentration proteins in plasma a pre-fractionation step, either hexapeptide bead-based libraries or anion exchange chromatography, was performed prior to surface...... enhanced laser desorption/ionization time-of-flight mass spectrometry analysis....

  12. EUV laser produced and induced plasmas for nanolithography

    Science.gov (United States)

    Sizyuk, Tatyana; Hassanein, Ahmed

    2017-10-01

    EUV produced plasma sources are being extensively studied for the development of new technology for computer chips production. Challenging tasks include optimization of EUV source efficiency, producing powerful source in 2 percentage bandwidth around 13.5 nm for high volume manufacture (HVM), and increasing the lifetime of collecting optics. Mass-limited targets, such as small droplet, allow to reduce contamination of chamber environment and mirror surface damage. However, reducing droplet size limits EUV power output. Our analysis showed the requirement for the target parameters and chamber conditions to achieve 500 W EUV output for HVM. The HEIGHTS package was used for the simulations of laser produced plasma evolution starting from laser interaction with solid target, development and expansion of vapor/plasma plume with accurate optical data calculation, especially in narrow EUV region. Detailed 3D modeling of mix environment including evolution and interplay of plasma produced by lasers from Sn target and plasma produced by in-band and out-of-band EUV radiation in ambient gas, used for the collecting optics protection and cleaning, allowed predicting conditions in entire LPP system. Effect of these conditions on EUV photon absorption and collection was analyzed. This work is supported by the National Science Foundation, PIRE project.

  13. Analysis of plasma microRNA expression profiles in male textile workers with noise-induced hearing loss.

    Science.gov (United States)

    Ding, Lu; Liu, Jing; Shen, Huan-Xi; Pan, Li-Ping; Liu, Qing-Dong; Zhang, Heng-Dong; Han, Lei; Shuai, Li-Guo; Ding, En-Min; Zhao, Qiu-Ni; Wang, Bo-Shen; Zhu, Bao-Li

    2016-03-01

    Circulating microRNAs (miRNAs) have attracted interests as non-invasive biomarkers of physiological and pathological conditions, which may be applied in noise-induced hearing loss (NIHL). However, no epidemiology studies have yet examined the potential effects of NIHL or noise exposure on miRNA expression profiles. We sought to identify permanent NIHL-related miRNAs and to predict the biological functions of the putative genes encoding the indicated miRNAs. In the discovery stage, we used a microarray assay to detect the miRNA expression profiles between pooled plasma samples from 10 noise-exposed individuals with normal hearing and 10 NIHL patients. In addition, we conducted a preliminary validation of six candidate miRNAs in the same 20 workers. Subsequently, three miRNAs were selected for expanded validation in 23 non-exposed individuals with normal hearing and 46 noise-exposed textile workers which including 23 noise-exposed workers with normal hearing and 23 NIHL patients. Moreover, we predicted the biological functions of the putative target genes using a Gene Ontology (GO) function enrichment analysis. In the discovery stage, compared with the noise exposures with normal hearing, 73 miRNAs demonstrated at least a 1.5-fold differential expression in the NIHL patients. In the preliminary validation, compared with the noise exposures, the plasma levels of miR-16-5p, miR-24-3p, miR-185-5p and miR-451a were all upregulated (P < 0.001) in the NIHL patients. In the expanded validation stage, compared with the non-exposures, the plasma levels of miR-24, miR-185-5p and miR-451a were all significantly downregulated (P < 0.001) in the exposures. And compared with the noise exposures, the plasma levels of miR-185-5p and miR-451a were slightly elevated (P < 0.001) in the NIHL patients, which were consistent with the results of preliminary validation and microarray analysis. The two indicated plasma miRNAs may be biomarkers of indicating responses to noise exposure

  14. Analysis of laser-induced evaporation of Al target under conditions of vapour plasma formation

    International Nuclear Information System (INIS)

    Mazhukin, V.I.; Nossov, V.V.; Smurov, I.

    2004-01-01

    The plasma-controlled evaporation of the Al target induced by the laser pulse with intensity of 10 9 W/cm 2 and wavelength of 1.06 μm is analysed with account for the two-dimensional effects. The self consistent model is applied, including the heat transfer equation in condensed medium, the equations of radiation gas dynamics in evaporated substance and the Knudsen layer model at the two media boundary. It is found that the phase transition at the target surface is controlled by the two factors: the surface temperature that depends on the transmitted radiation intensity, and the plasma pressure, governed by the expansion regime. The process comes through three characteristic stages, the sonic evaporation at the beginning, the condensation during the period of plasma formation and initial expansion, and finally, the re-start of evaporation in subsonic regime after the partial brightening of the plasma. During the subsonic evaporation stage the vapour flow and the mass removal rate are much higher near the beam boundaries than in the centre due to smaller plasma counter-pressure. The vapour plasma pattern is characterised by the dense hot zone near the surface where the absorption of laser energy occurs, and rapid decrease of density outside the zone due to three-dimensional expansion

  15. Quantitative lipidomic analysis of plasma and plasma lipoproteins using MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Serna, Jorge; García-Seisdedos, David; Alcázar, Alberto; Lasunción, Miguel Ángel; Busto, Rebeca; Pastor, Óscar

    2015-07-01

    Knowledge of the plasma lipid composition is essential to clarify the specific roles of different lipid species in various pathophysiological processes. In this study, we developed an analytical strategy combining high-performance liquid chromatography with evaporative light scattering detection (HPLC-ELSD) and off-line coupling with matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry (MALDI-TOF/MS) to determine the composition of plasma and major lipoproteins at two levels, lipid classes and lipid species. We confirmed the suitability of MALDI-TOF/MS as a quantitative measurement tool studying the linearity and repeatability for triglycerides (TG), phosphatidylethanolamine (PE) and phosphatidylcholine (PC). Moreover, data obtained with this method were correlated with other lipid classes and species measurements using currently available technologies. To establish the potential utility of our approach, human plasma very low density- (VLDL), low density- (LDL) and high density- (HDL) lipoproteins from 10 healthy donors were separated using ultracentrifugation, and compositions of nine lipid classes, cholesteryl esters (CE), TG, free cholesterol (FC), PE, phosphatidylinositol (PI), sulfatides (S), PC, lysophosphatidylcholine (LPC) and sphingomyelin (SM), analyzed. In total, 157 lipid species in plasma, 182 in LDL, 171 in HDL, and 148 in VLDL were quantified. The lipidomic profile was consistent with known differences in lipid classes, but also revealed unexpected differences in lipid species distribution of lipoproteins, particularly for LPC and SM. In summary, the methodology developed in this study constitutes a valid approach to determine the lipidomic composition of plasma and lipoproteins. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Statistical analysis of trace metals in the plasma of cancer patients versus controls

    International Nuclear Information System (INIS)

    Pasha, Qaisara; Malik, Salman A.; Shah, Munir H.

    2008-01-01

    The plasma of cancer patients (n = 112) and controls (n = 118) were analysed for selected trace metals (Al, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sr and Zn) by flame atomic absorption spectroscopy. In the plasma of cancer patients, mean concentrations of macronutrients/essential metals, Na, K, Ca, Mg, Fe and Zn were 3971, 178, 44.1, 7.59, 4.38 and 3.90 ppm, respectively, while the mean metal levels in the plasma of controls were 3844, 151, 74.2, 18.0, 6.60 and 2.50 ppm, respectively. Average concentrations of Cd, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Sr and Zn were noted to be significantly higher in the plasma of cancer patients compared with controls. Very strong mutual correlations (r > 0.70) in the plasma of cancer patients were observed between Fe-Mn, Ca-Mn, Ca-Ni, Ca-Co, Cd-Pb, Co-Ni, Mn-Ni, Mn-Zn, Cr-Li, Ca-Zn and Fe-Ni, whereas, Ca-Mn, Ca-Mg, Fe-Zn, Ca-Zn, Mg-Mn, Mg-Zn, Cd-Sb, Cd-Co, Cd-Zn, Co-Sb and Sb-Zn exhibited strong relationships (r > 0.50) in the plasma of controls, all were significant at p < 0.01. Principal component analysis (PCA) of the data extracted five PCs, both for cancer patients and controls, but with considerably different loadings. The average metals levels in male and female donors of the two groups were also evaluated and in addition, the general role of trace metals in the carcinogenesis was discussed. The study indicated appreciably different pattern of metal distribution and mutual relationships in the plasma of cancer patients in comparison with controls

  17. Statistical analysis of trace metals in the plasma of cancer patients versus controls

    Energy Technology Data Exchange (ETDEWEB)

    Pasha, Qaisara; Malik, Salman A. [Department of Biochemistry, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Shah, Munir H. [Department of Chemistry, Quaid-i-Azam University, Islamabad 45320 (Pakistan)], E-mail: munir_qau@yahoo.com

    2008-05-30

    The plasma of cancer patients (n = 112) and controls (n = 118) were analysed for selected trace metals (Al, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sr and Zn) by flame atomic absorption spectroscopy. In the plasma of cancer patients, mean concentrations of macronutrients/essential metals, Na, K, Ca, Mg, Fe and Zn were 3971, 178, 44.1, 7.59, 4.38 and 3.90 ppm, respectively, while the mean metal levels in the plasma of controls were 3844, 151, 74.2, 18.0, 6.60 and 2.50 ppm, respectively. Average concentrations of Cd, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Sr and Zn were noted to be significantly higher in the plasma of cancer patients compared with controls. Very strong mutual correlations (r > 0.70) in the plasma of cancer patients were observed between Fe-Mn, Ca-Mn, Ca-Ni, Ca-Co, Cd-Pb, Co-Ni, Mn-Ni, Mn-Zn, Cr-Li, Ca-Zn and Fe-Ni, whereas, Ca-Mn, Ca-Mg, Fe-Zn, Ca-Zn, Mg-Mn, Mg-Zn, Cd-Sb, Cd-Co, Cd-Zn, Co-Sb and Sb-Zn exhibited strong relationships (r > 0.50) in the plasma of controls, all were significant at p < 0.01. Principal component analysis (PCA) of the data extracted five PCs, both for cancer patients and controls, but with considerably different loadings. The average metals levels in male and female donors of the two groups were also evaluated and in addition, the general role of trace metals in the carcinogenesis was discussed. The study indicated appreciably different pattern of metal distribution and mutual relationships in the plasma of cancer patients in comparison with controls.

  18. Dynamic plasma screening effects on semiclassical inelastic electron endash ion collisions in dense plasmas

    International Nuclear Information System (INIS)

    Jung, Y.

    1997-01-01

    In dense plasmas, dynamic plasma screening effects are investigated on 1s→2p dipole transition probabilities for electron-impact excitation of hydrogenic ions. The electron endash ion interaction potential is considered by introduction of the plasma dielectric function. A semiclassical straight-line trajectory method is applied to the path of the projectile electron in order to visualize the semiclassical transition probability as a function of the impact parameter, projectile energy, and plasma parameters. The transition probability including the dynamic plasma screening effect is always greater than that including the static plasma screening effect. When the projectile velocity is smaller than the electron thermal velocity, the dynamic polarization screening effect becomes the static plasma screening effect. When the projectile velocity is greater than the electron thermal velocity, then the interaction potential is almost unshielded. The difference between the dynamic and static plasma screening effects is more significant for low-energy projectiles. It is also found that the static plasma screening formula obtained by the Debye endash Hueckel model overestimates the plasma screening effects on the atomic excitation processes in dense plasmas. copyright 1997 American Institute of Physics

  19. Plasma immersion surface modification with metal ion plasma

    International Nuclear Information System (INIS)

    Brown, I.G.; Yu, K.M.; Godechot, X.

    1991-04-01

    We describe here a novel technique for surface modification in which metal plasma is employed and by which various blends of plasma deposition and ion implantation can be obtained. The new technique is a variation of the plasma immersion technique described by Conrad and co-workers. When a substrate is immersed in a metal plasma, the plasma that condenses on the substrate remains there as a film, and when the substrate is then implanted, qualitatively different processes can follow, including' conventional' high energy ion implantation, recoil implantation, ion beam mixing, ion beam assisted deposition, and metallic thin film and multilayer fabrication with or without species mixing. Multiple metal plasma guns can be used with different metal ion species, films can be bonded to the substrate through ion beam mixing at the interface, and multilayer structures can be tailored with graded or abrupt interfaces. We have fabricated several different kinds of modified surface layers in this way. 22 refs., 4 figs

  20. Radiometric-microbiologic assay fo vitamin B-6: analysis of plasma samples

    International Nuclear Information System (INIS)

    Guilarte, T.R.; McIntyre, P.A.

    1981-01-01

    A radiometric microbiologic assay for the analysis of vitamin B-6 in plasma was developed. The method is based on the measurement of 14CO2 generated from the metabolism of DL-l-14C-valine (L-l-14C-valine) by Kloeckera brevis. The assay is specific for the biologically active forms of the vitamin, that is, pyridoxine, pyridoxal and pyridoxamine, and their respective phosphorylated forms. The biologically inert vitamin B-6 metabolite (4-pyridoxic acid) did not generate a response at concentrations tested. The radiometric technique was shown to be sensitive to the 1 nanogram level. Reproducibility and recovery studies gave good results. Fifteen plasma samples were assayed using the radiometric and turbidimetric techniques. The correlation coefficient was r . 0.98. Turbid material or precipitated debris did not interfere with the radiometric microbiologic assay, thus allowing for simplification of assay procedure

  1. Flow induced dispersion analysis rapidly quantifies proteins in human plasma samples

    DEFF Research Database (Denmark)

    Poulsen, Nicklas N; Andersen, Nina Z; Østergaard, Jesper

    2015-01-01

    Rapid and sensitive quantification of protein based biomarkers and drugs is a substantial challenge in diagnostics and biopharmaceutical drug development. Current technologies, such as ELISA, are characterized by being slow (hours), requiring relatively large amounts of sample and being subject...... to cumbersome and expensive assay development. In this work a new approach for quantification based on changes in diffusivity is presented. The apparent diffusivity of an indicator molecule interacting with the protein of interest is determined by Taylor Dispersion Analysis (TDA) in a hydrodynamic flow system...... in a blood plasma matrix), fully automated, and being subject to a simple assay development. FIDA is demonstrated for quantification of the protein Human Serum Albumin (HSA) in human plasma as well as for quantification of an antibody against HSA. The sensitivity of the FIDA assay depends on the indicator...

  2. Quantitative plasma biomarker analysis in HDI exposure assessment.

    Science.gov (United States)

    Flack, Sheila L; Fent, Kenneth W; Trelles Gaines, Linda G; Thomasen, Jennifer M; Whittaker, Steve; Ball, Louise M; Nylander-French, Leena A

    2010-01-01

    Quantification of amines in biological samples is important for evaluating occupational exposure to diisocyanates. In this study, we describe the quantification of 1,6-hexamethylene diamine (HDA) levels in hydrolyzed plasma of 46 spray painters applying 1,6-hexamethylene diisocyanate (HDI)-containing paint in vehicle repair shops collected during repeated visits to their workplace and their relationship with dermal and inhalation exposure to HDI monomer. HDA was detected in 76% of plasma samples, as heptafluorobutyryl derivatives, and the range of HDA concentrations was HDA levels and HDI inhalation exposure measured on the same workday was low (N = 108, r = 0.22, P = 0.026) compared with the correlation between plasma HDA levels and inhalation exposure occurring approximately 20 to 60 days before blood collection (N = 29, r = 0.57, P = 0.0014). The correlation between plasma HDA levels and HDI dermal exposure measured on the same workday, although statistically significant, was low (N = 108, r = 0.22, P = 0.040) while the correlation between HDA and dermal exposure occurring approximately 20 to 60 days before blood collection was slightly improved (N = 29, r = 0.36, P = 0.053). We evaluated various workplace factors and controls (i.e. location, personal protective equipment use and paint booth type) as modifiers of plasma HDA levels. Workers using a downdraft-ventilated booth had significantly lower plasma HDA levels relative to semi-downdraft and crossdraft booth types (P = 0.0108); this trend was comparable to HDI inhalation and dermal exposure levels stratified by booth type. These findings indicate that HDA concentration in hydrolyzed plasma may be used as a biomarker of cumulative inhalation and dermal exposure to HDI and for investigating the effectiveness of exposure controls in the workplace.

  3. Analysis of the plasma proteome in COPD: Novel low abundance proteins reflect the severity of lung remodeling.

    Science.gov (United States)

    Merali, Salim; Barrero, Carlos A; Bowler, Russell P; Chen, Diane Er; Criner, Gerard; Braverman, Alan; Litwin, Samuel; Yeung, Anthony; Kelsen, Steven G

    2014-04-01

    The search for COPD biomarkers has largely employed a targeted approach that focuses on plasma proteins involved in the systemic inflammatory response and in lung injury and repair. This proof of concept study was designed to test the idea that an open, unbiased, in-depth proteomics approach could identify novel, low abundance plasma proteins i.e., ng/mL concentration, which could serve as potential biomarkers. Differentially expressed proteins were identified in a discovery group with severe COPD (FEV1 <45% predicted; n = 10). Subjects with normal lung function matched for age, sex, ethnicity and smoking history served as controls (n = 10). Pooled plasma from each group was exhaustively immunodepleted of abundant proteins, d separated by 1-D gel electrophoresis and extensively fractionated prior to LC-tandem mass spectroscopy (GeLC-MS). Thirty one differentially expressed proteins were identified in the discovery group including markers of lung defense against oxidant stress, alveolar macrophage activation, and lung tissue injury and repair. Four of the 31 proteins (i.e., GRP78, soluble CD163, IL1AP and MSPT9) were measured in a separate verification group of 80 subjects with varying COPD severity by immunoassay. All 4 were significantly altered in COPD and 2 (GRP78 and soluble CD163) correlated with both FEV1 and the extent of emphysema. In-depth, plasma proteomic analysis identified a group of novel, differentially expressed, low abundance proteins that reflect known pathogenic mechanisms and the severity of lung remodeling in COPD. These proteins may also prove useful as COPD biomarkers.

  4. Plasma physics for controlled fusion

    International Nuclear Information System (INIS)

    Miyamoto, K.

    2010-01-01

    The primary objective of this lecture note is to present the theories and experiments of plasma physics for recent activities of controlled fusion research for graduate and senior undergraduate students. Chapters 1-6 describe the basic knowledge of plasma and magnetohydrodynamics (MHD). MHD instabilities limit the beta ratio (ratio of plasma pressure to magnetic pressure) of confined plasma. Chapters 7-9 provide the kinetic theory of hot plasma and discuss the wave heating and non-inductive current drive. The dispersion relation derived by the kinetic theory are used to discuss plasma waves and perturbed modes. Landau damping is the essential mechanism of plasma heating and the stabilization of perturbation. Landau inverse damping brings the amplification of waves and the destabilization of perturbed modes. Chapter 10 explains the plasma transport due to turbulence, which is the most important and challenging subject for plasma confinement. Theories and simulations including subject of zonal flow are introduced. Chapters 11, 12 and 13 describe the recent activities of tokamak including ITER as well as spherical tokamak, reversed field pinch (RFP) and stellarator including quasi-symmetric configurations. Emphasis has been given to tokamak research since it made the most remarkable progress and the construction phase of 'International Tokamak Experimental Reactor' called ITER has already started. (author)

  5. Plasma Metabolites Predict Severity of Depression and Suicidal Ideation in Psychiatric Patients-A Multicenter Pilot Analysis.

    Science.gov (United States)

    Setoyama, Daiki; Kato, Takahiro A; Hashimoto, Ryota; Kunugi, Hiroshi; Hattori, Kotaro; Hayakawa, Kohei; Sato-Kasai, Mina; Shimokawa, Norihiro; Kaneko, Sachie; Yoshida, Sumiko; Goto, Yu-Ichi; Yasuda, Yuka; Yamamori, Hidenaga; Ohgidani, Masahiro; Sagata, Noriaki; Miura, Daisuke; Kang, Dongchon; Kanba, Shigenobu

    2016-01-01

    Evaluating the severity of depression (SOD), especially suicidal ideation (SI), is crucial in the treatment of not only patients with mood disorders but also psychiatric patients in general. SOD has been assessed on interviews such as the Hamilton Rating Scale for Depression (HAMD)-17, and/or self-administered questionnaires such as the Patient Health Questionnaire (PHQ)-9. However, these evaluation systems have relied on a person's subjective information, which sometimes lead to difficulties in clinical settings. To resolve this limitation, a more objective SOD evaluation system is needed. Herein, we collected clinical data including HAMD-17/PHQ-9 and blood plasma of psychiatric patients from three independent clinical centers. We performed metabolome analysis of blood plasma using liquid chromatography mass spectrometry (LC-MS), and 123 metabolites were detected. Interestingly, five plasma metabolites (3-hydroxybutyrate (3HB), betaine, citrate, creatinine, and gamma-aminobutyric acid (GABA)) are commonly associated with SOD in all three independent cohort sets regardless of the presence or absence of medication and diagnostic difference. In addition, we have shown several metabolites are independently associated with sub-symptoms of depression including SI. We successfully created a classification model to discriminate depressive patients with or without SI by machine learning technique. Finally, we produced a pilot algorithm to predict a grade of SI with citrate and kynurenine. The above metabolites may have strongly been associated with the underlying novel biological pathophysiology of SOD. We should explore the biological impact of these metabolites on depressive symptoms by utilizing a cross species study model with human and rodents. The present multicenter pilot study offers a potential utility for measuring blood metabolites as a novel objective tool for not only assessing SOD but also evaluating therapeutic efficacy in clinical practice. In addition

  6. Plasma Metabolites Predict Severity of Depression and Suicidal Ideation in Psychiatric Patients-A Multicenter Pilot Analysis.

    Directory of Open Access Journals (Sweden)

    Daiki Setoyama

    Full Text Available Evaluating the severity of depression (SOD, especially suicidal ideation (SI, is crucial in the treatment of not only patients with mood disorders but also psychiatric patients in general. SOD has been assessed on interviews such as the Hamilton Rating Scale for Depression (HAMD-17, and/or self-administered questionnaires such as the Patient Health Questionnaire (PHQ-9. However, these evaluation systems have relied on a person's subjective information, which sometimes lead to difficulties in clinical settings. To resolve this limitation, a more objective SOD evaluation system is needed. Herein, we collected clinical data including HAMD-17/PHQ-9 and blood plasma of psychiatric patients from three independent clinical centers. We performed metabolome analysis of blood plasma using liquid chromatography mass spectrometry (LC-MS, and 123 metabolites were detected. Interestingly, five plasma metabolites (3-hydroxybutyrate (3HB, betaine, citrate, creatinine, and gamma-aminobutyric acid (GABA are commonly associated with SOD in all three independent cohort sets regardless of the presence or absence of medication and diagnostic difference. In addition, we have shown several metabolites are independently associated with sub-symptoms of depression including SI. We successfully created a classification model to discriminate depressive patients with or without SI by machine learning technique. Finally, we produced a pilot algorithm to predict a grade of SI with citrate and kynurenine. The above metabolites may have strongly been associated with the underlying novel biological pathophysiology of SOD. We should explore the biological impact of these metabolites on depressive symptoms by utilizing a cross species study model with human and rodents. The present multicenter pilot study offers a potential utility for measuring blood metabolites as a novel objective tool for not only assessing SOD but also evaluating therapeutic efficacy in clinical practice. In

  7. Positional instability analysis of tokamak plasmas by ERATO

    International Nuclear Information System (INIS)

    Kumagai, Michikazu; Tsunematsu, Toshihide; Tokuda, Shinji; Takeda, Tatsuoki

    1983-06-01

    The stability of axisymmetric modes of a tokamak plasma(positional instabilities) is analyzed for the Solov'ev equilibrium by using the linear ideal MHD code ERATO-J. The dependence of the stability on various parameters, i.e., the ellipticity and triangularity of the plasma cross-section, the aspect ratio, the safety factor at the magnetic axis, and the distance between the plasma and a conducting shell is investigated. Comparison of the results with those by the rigid model shows that the stability condition derived from the rigid model in terms of the decay index(n-index) of the external equilibrating field is a good approximation for the plasma with small triangular deformation. Also the results are compared with those of the rigid displacement model and applicability of the various models on the positional instability analyses is discussed. (author)

  8. Plasma concentrations and intakes of amino acids in male meat-eaters, fish-eaters, vegetarians and vegans: a cross-sectional analysis in the EPIC-Oxford cohort.

    Science.gov (United States)

    Schmidt, J A; Rinaldi, S; Scalbert, A; Ferrari, P; Achaintre, D; Gunter, M J; Appleby, P N; Key, T J; Travis, R C

    2016-03-01

    We aimed to investigate the differences in plasma concentrations and in intakes of amino acids between male meat-eaters, fish-eaters, vegetarians and vegans in the Oxford arm of the European Prospective Investigation into Cancer and Nutrition. This cross-sectional analysis included 392 men, aged 30-49 years. Plasma amino acid concentrations were measured with a targeted metabolomic approach using mass spectrometry, and dietary intake was assessed using a food frequency questionnaire. Differences between diet groups in mean plasma concentrations and intakes of amino acids were examined using analysis of variance, controlling for potential confounding factors and multiple testing. In plasma, concentrations of 6 out of 21 amino acids varied significantly by diet group, with differences of -13% to +16% between meat-eaters and vegans. Concentrations of methionine, tryptophan and tyrosine were highest in fish-eaters and vegetarians, followed by meat-eaters, and lowest in vegans. A broadly similar pattern was seen for lysine, whereas alanine concentration was highest in fish-eaters and lowest in meat-eaters. For glycine, vegans had the highest concentration and meat-eaters the lowest. Intakes of all 18 dietary amino acids differed by diet group; for the majority of these, intake was highest in meat-eaters followed by fish-eaters, then vegetarians and lowest in vegans (up to 47% lower than in meat-eaters). Men belonging to different habitual diet groups have significantly different plasma concentrations of lysine, methionine, tryptophan, alanine, glycine and tyrosine. However, the differences in plasma concentrations were less marked than and did not necessarily mirror those seen for amino acid intakes.

  9. Plasma Interactions with Mixed Materials and Impurity Transport

    Energy Technology Data Exchange (ETDEWEB)

    Rognlien, T. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Beiersdorfer, Peter [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chernov, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Frolov, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Magee, E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rudd, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Umansky, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-28

    The project brings together three discipline areas at LLNL to develop advanced capability to predict the impact of plasma/material interactions (PMI) on metallic surfaces in magnetic fusion energy (MFE) devices. These areas are (1) modeling transport of wall impurity ions through the edge plasma to the core plasma, (2) construction of a laser blow-off (LBO) system for injecting precise amounts of metallic atoms into a tokamak plasma, and (3) material science analysis of fundamental processes that modify metallic surfaces during plasma bombardment. The focus is on tungsten (W), which is being used for the ITER divertor and in designs of future MFE devices. In area (1), we have worked with the University of California, San Diego (UCSD) on applications of the UEDGE/DUSTT coupled codes to predict the influx of impurity ions from W dust through the edge plasma, including periodic edge-plasma oscillations, and revived a parallel version of UEDGE to speed up these simulations. In addition, the impurity transport model in the 2D UEDGE code has been implemented into the 3D BOUT++ turbulence/transport code to allow fundamental analysis of the impact of strong plasma turbulence on the impurity transport. In area (2), construction and testing of the LBO injection system has been completed. The original plan to install the LBO on the National Spherical Torus Experiment Upgrade (NSTX-U) at Princeton and its use to validate the impurity transport simulations is delayed owing to NSTX-U being offline for substantial magnetic coil repair period. In area (3), an analytic model has been developed to explain the growth of W tendrils (or fuzz) observed for helium-containing plasmas. Molecular dynamics calculations of W sputtering by W and deuterium (D) ions shows that a spatial blending of interatomic potentials is needed to describe the near-surface and deeper regions of the material.

  10. Plasma Interactions with Mixed Materials and Impurity Transport

    International Nuclear Information System (INIS)

    Rognlien, T. D.; Beiersdorfer, Peter; Chernov, A.; Frolov, T.; Magee, E.; Rudd, R.; Umansky, M.

    2016-01-01

    The project brings together three discipline areas at LLNL to develop advanced capability to predict the impact of plasma/material interactions (PMI) on metallic surfaces in magnetic fusion energy (MFE) devices. These areas are (1) modeling transport of wall impurity ions through the edge plasma to the core plasma, (2) construction of a laser blow-off (LBO) system for injecting precise amounts of metallic atoms into a tokamak plasma, and (3) material science analysis of fundamental processes that modify metallic surfaces during plasma bombardment. The focus is on tungsten (W), which is being used for the ITER divertor and in designs of future MFE devices. In area (1), we have worked with the University of California, San Diego (UCSD) on applications of the UEDGE/DUSTT coupled codes to predict the influx of impurity ions from W dust through the edge plasma, including periodic edge-plasma oscillations, and revived a parallel version of UEDGE to speed up these simulations. In addition, the impurity transport model in the 2D UEDGE code has been implemented into the 3D BOUT++ turbulence/transport code to allow fundamental analysis of the impact of strong plasma turbulence on the impurity transport. In area (2), construction and testing of the LBO injection system has been completed. The original plan to install the LBO on the National Spherical Torus Experiment Upgrade (NSTX-U) at Princeton and its use to validate the impurity transport simulations is delayed owing to NSTX-U being offline for substantial magnetic coil repair period. In area (3), an analytic model has been developed to explain the growth of W tendrils (or fuzz) observed for helium-containing plasmas. Molecular dynamics calculations of W sputtering by W and deuterium (D) ions shows that a spatial blending of interatomic potentials is needed to describe the near-surface and deeper regions of the material.

  11. BOOK REVIEW: Kinetic theory of plasma waves, homogeneous plasmas

    Science.gov (United States)

    Porkolab, Miklos

    1998-11-01

    addition to the literature, for it gives the teacher of the subject a valuable reference where the inquisitive student will be able to read up on and satisfy himself about the practicality and reliability of the Vlasov theory in a hot magnetized and collisionless plasma. The book has excellent treatments of several new topics not included in previous textbooks, for example, the relativistic theory of plasma wave propagation, so important in electron cyclotron heating of magnetically confined fusion plasmas, a discussion of current drive theory and there is a welcome introduction to parametric instabilities in the final chapter. There are some things that make the readability of the book somewhat difficult. In the early parts, certain advanced concepts are introduced without much motivation or explanation, although the author is trying to be helpful by providing a list of relevant references at the end of each chapter. Here the teacher's role will be critical. Again, a certain amount of previous knowledge of the subject would prove to be invaluable to the student. The main content of the book is included in 11 chapters. Use is made of CGS Gaussian units, a favourite of plasma theorists. As the author states, these are still widely used in advanced plasma theory, and the student is well advised to become familiar with this system of units (as well as the SI system for applications). To help the reader in the Introduction, the author defines various expressions often used in plasma physics in practical units (frequencies in hertz, lengths in centimetres, temperatures in kiloelectronvolts and magnetic fields in teslas). Chapter 2 is entitled `Plasma Electrodynamics' and it introduces the Maxwell-Vlasov set of equations, as well as the important fundamentals of wave propagation, such as polarization, dispersion and the dielectric tensor, and energy relations. In Chapter 3, `Elementary Plasma Kinetic Theory', the author derives the Vlasov equation and the Fokker-Planck equation

  12. High-throughput fractionation of human plasma for fast enrichment of low- and high-abundance proteins.

    Science.gov (United States)

    Breen, Lucas; Cao, Lulu; Eom, Kirsten; Srajer Gajdosik, Martina; Camara, Lila; Giacometti, Jasminka; Dupuy, Damian E; Josic, Djuro

    2012-05-01

    Fast, cost-effective and reproducible isolation of IgM from plasma is invaluable to the study of IgM and subsequent understanding of the human immune system. Additionally, vast amounts of information regarding human physiology and disease can be derived from analysis of the low abundance proteome of the plasma. In this study, methods were optimized for both the high-throughput isolation of IgM from human plasma, and the high-throughput isolation and fractionation of low abundance plasma proteins. To optimize the chromatographic isolation of IgM from human plasma, many variables were examined including chromatography resin, mobile phases, and order of chromatographic separations. Purification of IgM was achieved most successfully through isolation of immunoglobulin from human plasma using Protein A chromatography with a specific resin followed by subsequent fractionation using QA strong anion exchange chromatography. Through these optimization experiments, an additional method was established to prepare plasma for analysis of low abundance proteins. This method involved chromatographic depletion of high-abundance plasma proteins and reduction of plasma proteome complexity through further chromatographic fractionation. Purification of IgM was achieved with high purity as confirmed by SDS-PAGE and IgM-specific immunoblot. Isolation and fractionation of low abundance protein was also performed successfully, as confirmed by SDS-PAGE and mass spectrometry analysis followed by label-free quantitative spectral analysis. The level of purity of the isolated IgM allows for further IgM-specific analysis of plasma samples. The developed fractionation scheme can be used for high throughput screening of human plasma in order to identify low and high abundance proteins as potential prognostic and diagnostic disease biomarkers.

  13. Design concept of conducting shell and in-vessel components suitable for plasma vertical stability and remote maintenance scheme in DEMO reactor

    Energy Technology Data Exchange (ETDEWEB)

    Utoh, Hiroyasu, E-mail: uto.hiroyasu@jaea.go.jp [Japan Atomic Energy Agency, Obuchi, Rokkasho-mura, Aomori-ken 039-3212 (Japan); International Fusion Energy Research Centre, 2-166, Obuchi, Rokkasho, Aomori 039-3212 (Japan); Takase, Haruhiko [Japan Atomic Energy Agency, Obuchi, Rokkasho-mura, Aomori-ken 039-3212 (Japan); International Fusion Energy Research Centre, 2-166, Obuchi, Rokkasho, Aomori 039-3212 (Japan); Sakamoto, Yoshiteru; Tobita, Kenji [Japan Atomic Energy Agency, Obuchi, Rokkasho-mura, Aomori-ken 039-3212 (Japan); Mori, Kazuo; Kudo, Tatsuya [Japan Atomic Energy Agency, Obuchi, Rokkasho-mura, Aomori-ken 039-3212 (Japan); International Fusion Energy Research Centre, 2-166, Obuchi, Rokkasho, Aomori 039-3212 (Japan); Someya, Youji; Asakura, Nobuyuki; Hoshino, Kazuo; Nakamura, Makoto; Tokunaga, Shinsuke [Japan Atomic Energy Agency, Obuchi, Rokkasho-mura, Aomori-ken 039-3212 (Japan)

    2016-02-15

    Highlights: • Conceptual design of in-vessel component including conducting shell has been investigated. • The conducting shell design for plasma vertical stability was clarified from the plasma vertical stability analysis. • The calculation results showed that the double-loop shell has the most effect on plasma vertical stability. - Abstract: In order to realize a feasible DEMO, we designed an in-vessel component including the conducting shell. The project is affiliated with the broader approach DEMO design activities and is conceptualized from a plasma vertical stability and engineering viewpoint. The dependence of the plasma vertical stability on the conducing shell parameters and the electromagnetic force at plasma disruption were investigated in numerical simulations (programmed in the 3D eddy current analysis code and a plasma position control code). The simulations assumed the actual shape and position of the vacuum vessel and in-vessel components. The plasma vertical stability was most effectively maintained by the double-loop shell.

  14. Two dimensional kinetic analysis of electrostatic harmonic plasma waves

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca-Pongutá, E. C.; Ziebell, L. F.; Gaelzer, R. [Instituto de Física, UFRGS, 91501-970 Porto Alegre, RS (Brazil); Yoon, P. H. [IPST, University of Maryland, College Park, Maryland 20742 (United States); SSR, Kyung Hee University, Yongin, Gyeonggi 446-701 (Korea, Republic of)

    2016-06-15

    Electrostatic harmonic Langmuir waves are virtual modes excited in weakly turbulent plasmas, first observed in early laboratory beam-plasma experiments as well as in rocket-borne active experiments in space. However, their unequivocal presence was confirmed through computer simulated experiments and subsequently theoretically explained. The peculiarity of harmonic Langmuir waves is that while their existence requires nonlinear response, their excitation mechanism and subsequent early time evolution are governed by essentially linear process. One of the unresolved theoretical issues regards the role of nonlinear wave-particle interaction process over longer evolution time period. Another outstanding issue is that existing theories for these modes are limited to one-dimensional space. The present paper carries out two dimensional theoretical analysis of fundamental and (first) harmonic Langmuir waves for the first time. The result shows that harmonic Langmuir wave is essentially governed by (quasi)linear process and that nonlinear wave-particle interaction plays no significant role in the time evolution of the wave spectrum. The numerical solutions of the two-dimensional wave spectra for fundamental and harmonic Langmuir waves are also found to be consistent with those obtained by direct particle-in-cell simulation method reported in the literature.

  15. High speed cine film studies of plasma behaviour and plasma surface interactions in tokamaks

    International Nuclear Information System (INIS)

    Goodall, D.H.J.

    1982-01-01

    High speed cine photography is a useful diagnostic aid for studying plasma behaviour and plasma surface interactions. Several workers have filmed discharges in tokamaks including ASDEX, DITE, DIVA, ISX, JFT2, TFR and PLT. These films are discussed and examples given of the observed phenomena which include plasma limiter interactions, diverted discharges, disruptions, magnetic islands and moving glowing objects often known as 'UFOs'. Examples of plasma structures in ASDEX and DITE not previously published are also given. The paper also reports experiments in DITE to determine the origin of UFOs. (orig.)

  16. Impact of Relativistic Electron Beam on Hole Acoustic Instability in Quantum Semiconductor Plasmas

    Science.gov (United States)

    Siddique, M.; Jamil, M.; Rasheed, A.; Areeb, F.; Javed, Asif; Sumera, P.

    2018-01-01

    We studied the influence of the classical relativistic beam of electrons on the hole acoustic wave (HAW) instability exciting in the semiconductor quantum plasmas. We conducted this study by using the quantum-hydrodynamic model of dense plasmas, incorporating the quantum effects of semiconductor plasma species which include degeneracy pressure, exchange-correlation potential and Bohm potential. Analysis of the quantum characteristics of semiconductor plasma species along with relativistic effect of beam electrons on the dispersion relation of the HAW is given in detail qualitatively and quantitatively by plotting them numerically. It is worth mentioning that the relativistic electron beam (REB) stabilises the HAWs exciting in semiconductor (GaAs) degenerate plasma.

  17. Studies on waves and turbulence in natural plasmas and in laboratory plasmas

    International Nuclear Information System (INIS)

    Ferreira, J.L.

    1990-09-01

    The project for studying plasma waves and plasma turbulence submitted to CAPES to be included in the CAPES/COFECUB international cooperation agreement is presented. The project will be carry out in cooperation with Paris University aiming to simulate in laboratory wave-particle interaction phenomena occuring in space plasma. (M.C.K.)

  18. Feasibility, strategy, methodology, and analysis of probe measurements in plasma under high gas pressure

    Science.gov (United States)

    Demidov, V. I.; Koepke, M. E.; Kurlyandskaya, I. P.; Malkov, M. A.

    2018-02-01

    This paper reviews existing theories for interpreting probe measurements of electron distribution functions (EDF) at high gas pressure when collisions of electrons with atoms and/or molecules near the probe are pervasive. An explanation of whether or not the measurements are realizable and reliable, an enumeration of the most common sources of measurement error, and an outline of proper probe-experiment design elements that inherently limit or avoid error is presented. Additionally, we describe recent expanded plasma-condition compatibility for EDF measurement, including in applications of large wall probe plasma diagnostics. This summary of the authors’ experiences gained over decades of practicing and developing probe diagnostics is intended to inform, guide, suggest, and detail the advantages and disadvantages of probe application in plasma research.

  19. Higher Order Analysis of Turbulent Changes Found in the ELF Range Electric Field Plasma Before Major Earthquakes

    Science.gov (United States)

    Kosciesza, M.; Blecki, J. S.; Parrot, M.

    2014-12-01

    We report the structure function analysis of changes found in electric field in the ELF range plasma turbulence registered in the ionosphere over epicenter region of major earthquakes with depth less than 40 km that took place during 6.5 years of the scientific mission of the DEMETER satellite. We compare the data for the earthquakes for which we found turbulence with events without any turbulent changes. The structure functions were calculated also for the Polar CUSP region and equatorial spread F region. Basic studies of the turbulent processes were conducted with use of higher order spectra and higher order statistics. The structure function analysis was performed to locate and check if there are intermittent behaviors in the ionospheres plasma over epicenter region of the earthquakes. These registrations are correlated with the plasma parameters measured onboard DEMETER satellite and with geomagnetic indices.

  20. ''SensArray'' voltage sensor analysis in an inductively coupled plasma

    International Nuclear Information System (INIS)

    Titus, M. J.; Hsu, C. C.; Graves, D. B.

    2010-01-01

    A commercially manufactured PlasmaVolt sensor wafer was studied in an inductively coupled plasma reactor in an effort to validate sensor measurements. A pure Ar plasma at various powers (25-420 W), for a range of pressures (10-80 mT), and bias voltages (0-250 V) was utilized. A numerical sheath simulation was simultaneously developed in order to interpret experimental results. It was found that PlasmaVolt sensor measurements are proportional to the rf-current through the sheath. Under conditions such that the sheath impedance is dominantly capacitive, sensor measurements follow a scaling law derived from the inhomogeneous sheath model of Lieberman and Lichtenberg, [Principles of Plasma Discharges and Materials Processing (Wiley, New York, 2005)]. Under these conditions, sensor measurements are proportional to the square root of the plasma density at the plasma-sheath interface, the one-fourth root of the electron temperature, and the one-fourth root of the rf bias voltage. When the sheath impedance becomes increasingly resistive, the sensor measurements deviate from the scaling law and tend to be directly proportional to the plasma density. The measurements and numerical sheath simulation demonstrate the scaling behavior as a function of changing sheath impedance for various plasma conditions.

  1. About numerical analysis of a plasma physics problem

    International Nuclear Information System (INIS)

    Almeida Cipolatti, R. de

    1985-01-01

    A numerical study on macroscopic equilibrium of a plasma at interior of a tokamak device, considering boundary problems for the case which f(s)=sis presented. The abstract Dirichlet problem enumerating main results which is applied to plasma model is studied. (M.C.K.) [pt

  2. Views of Prospective Science Teachers on Including the Concept of Plasma in Science Curricula

    Science.gov (United States)

    Balbag, Mustafa Zafer

    2018-01-01

    States of matter are structures that we may easily encounter in the universe as well as our close environment. The plasma state is the fourth state of matter, and it has much different properties in comparison to the solid, liquid and gas states of matter. In order to understand the universe and the environment we live in better, one needs to have…

  3. Edge-plasma analysis for liquid-wall MFE concepts

    International Nuclear Information System (INIS)

    Moir, R.W.; Rensink, M.E.; Rognlien, T.D.

    2001-01-01

    A thick flowing layer of liquid (e.g., flibe - a molten salt, or Sn 80 Li 20 - a liquid metal) protects the structural walls of the magnetic fusion configuration so that they can last the life of the plant even with intense 14 MeV neutron bombardment from the D-T fusion reaction. The surface temperature of the liquid rises as it passes from the inlet nozzles to the exit nozzles due to absorption of line and bremsstrahlung radiation, and neutrons. The surface temperature can be reduced by enhanced turbulent convection of hot surface liquid into the cooler interior. This surface temperature is affected by the temperature of liquid from a heat transport and energy recovery system. The evaporative flux from the wall driven by the surface temperature must also result in an acceptable impurity level in the core plasma. The shielding of the core by the edge plasma is modeled with a 2D-transport code for the DT and impurity ions; these impurity ions are either swept out to the divertor, or diffuse to the hot plasma core. An auxiliary plasma between the edge plasma and the liquid wall may further attenuate evaporating flux of atoms and molecules by ionization near the wall. (author)

  4. Analysis of autologous platelet-rich plasma during ascending and transverse aortic arch surgery.

    Science.gov (United States)

    Zhou, Shao-Feng; Estrera, Anthony L; Miller, Charles C; Ignacio, Craig; Panthayi, Sreelatha; Loubser, Paul; Sagun, Dean L; Sheinbaum, Roy; Safi, Hazim J

    2013-05-01

    Coagulopathy is a common complication after ascending and transverse arch aortic surgery with profound hypothermic circuit arrest (PHCA). Blood conservation strategies to reduce transfusion have been ongoing and involve multiple treatment modalities in modern cardiac surgery. The purpose of this study is to evaluate the effectiveness of autologous platelet-rich plasma (aPRP) as a blood conservation technique to reduce blood transfusion in ascending and arch aortic surgery. Between 2003 and 2009, we retrospectively reviewed 685 cases of ascending aorta and transverse arch repair using PHCA. A total of 287 patients in which aPRP was used (aPRP group) were compared with 398 patients who did have aPRP (non-aPRP group). Perioperative transfusion requirements and clinical outcomes that included early mortality, postoperative stroke, renal dysfunction, prolonged ventilation, coagulopathy, and length of postoperative intensive care unit stay were analyzed. The data were analyzed by mean and frequency for continuous variables and qualitative variables. To account for potential selection bias, 2 types of propensity analysis were performed. In both unadjusted and adjusted analysis, perioperative transfusions were fewer in the aPRP group compared with the non-aPRP group: (3.9 units fewer packed red blood cells, 4.5 units fewer fresh frozen plasma, 7.9 units fewer platelets, and 6.8 units fewer cryoprecipitate). In all analyses, postoperative morbidity (stroke, duration of mechanical ventilation, and intensive care unit stay) were significantly improved. Hospital mortality rate was not significantly decreased. The utilization of aPRP was associated with a reduction in allogeneic blood transfusions as well as a decrease in early postoperative morbidity during repairs of the ascending and transverse arch aorta using PHCA. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Inductively coupled plasma emission spectroscopy. Part II: applications and fundamentals. Volume 2

    International Nuclear Information System (INIS)

    Boumans, P.W.J.M.

    1987-01-01

    This is the second part of the two-volume treatise by this well-known and respected author. This volume reviews applications of inductively coupled plasma atomic emission spectroscopy (ICP-AES), summarizes fundamental studies, and compares ICP-AES methods with other methods of analysis. The first six chapters are devoted to specific fields of application, including the following: metals and other industrial materials, geology, the environment, agriculture and food, biology and clinical analysis, and organic materials. The chapter on the analysis of organic materials also covers the special instrumental considerations required when organic solvents are introduced into an inductively coupled plasma. A chapter on the direct analysis of solids completes the first part of this volume. Each of the applications chapters begins with a summary of the types of samples that are encountered in that field, and the kinds of problems that an elemental analysis can help to solve. This is followed by a tutorial approach covering applicability, advantages, and limitations of the methods. The coverage is thorough, including sample handling, storage, and preparation, acid, and fusion dissolution, avoiding contamination, methods of preconcentration, the types of interferences that can be expected and ways to reduce them, and the types of ICP plasmas that are used. The second half of the volume covers fundamental studies of ICP-AES: basic processes of aerosol generation, plasma modeling and computer simulation, spectroscopic diagnostics, excitation mechanisms, and discharge characteristics. This section introduces the experimental and modeling methods that have been used to obtain fundamental information about ICPs

  6. Modeling of thermal plasma arc technology FY 1994 report

    International Nuclear Information System (INIS)

    Hawkes, G.L.; Nguyen, H.D.; Paik, S.; McKellar, M.G.

    1995-03-01

    The thermal plasma arc process is under consideration to thermally treat hazardous and radioactive waste. A computer model for the thermal plasma arc technology was designed as a tool to aid in the development and use of the plasma arc-Joule beating process. The value of this computer model is to: (a) aid in understanding the plasma arc-Joule beating process as applied to buried waste or exhumed buried waste, (b) help design melter geometry and electrode configuration, (c) calculate the process capability of vitrifying waste (i.e., tons/hour), (d) develop efficient plasma and melter operating conditions to optimize the process and/or reduce safety hazards, (e) calculate chemical reactions during treatment of waste to track chemical composition of off-gas products, and composition of final vitrified waste form and (f) help compare the designs of different plasma-arc facilities. A steady-state model of a two-dimensional axisymmetric transferred plasma arc has been developed and validated. A parametric analysis was performed that studied the effects of arc length, plasma gas composition, and input power on the temperatures and velocity profiles of the slag and plasma gas. A two-dimensional transient thermo-fluid model of the US Bureau of Mines plasma arc melter has been developed. This model includes the growth of a slag pool. The thermo-fluid model is used to predict the temperature and pressure fields within a plasma arc furnace. An analysis was performed to determine the effects of a molten metal pool on the temperature, velocity, and voltage fields within the slag. A robust and accurate model for the chemical equilibrium calculations has been selected to determine chemical composition of final waste form and off-gas based on the temperatures and pressures within the plasma-arc furnace. A chemical database has been selected. The database is based on the materials to be processed in the plasma arc furnaces

  7. Transport in the tokamak plasma edge

    International Nuclear Information System (INIS)

    Vold, E.L.

    1989-01-01

    Experimental observations characterize the edge plasma or boundary layer in magnetically confined plasmas as a region of great complexity. Evidence suggests the edge physics plays a key role in plasma confinement although the mechanism remains unresolved. This study focuses on issues in two areas: observed poloidal asymmetries in the Scrape Off Layer (SOL) edge plasma and the physical nature of the plasma-neutral recycling. A computational model solves the coupled two dimensional partial differential equations governing the plasma fluid density, parallel and radial velocities, electron and ion temperatures and neutral density under assumptions of toroidal symmetry, ambipolarity, anomalous diffusive radial flux, and neutral-ion thermal equilibrium. Drift flow and plasma potential are calculated as dependent quantities. Computational results are compared to experimental data for the CCT and TEXTOR:ALT-II tokamak limiter cases. Comparisons show drift flux is a major component of the poloidal flow in the SOL along the tangency/separatrix. Plasma-neutral recycling is characterized in several tokamak divertors, including the C-MOD device using magnetic flux surface coordinates. Recycling is characterized by time constant, τ rc , on the order of tens of milliseconds. Heat flux transients from the core into the edge on shorter time scales significantly increase the plasma temperatures at the target and may increase sputtering. Recycling conditions in divertors vary considerably depending on recycled flux to the core. The high density, low temperature solution requires that the neutral mean free path be small compared to the divertor target to x-point distance. The simulations and analysis support H-mode confinement and transition models based on the recycling divertor solution bifurcation

  8. Current status of DIII-D real-time digital plasma control

    International Nuclear Information System (INIS)

    Penaflor, B.G.; Piglowski, D.A.; Ferron, J.R.; Walker, M.L.

    1999-06-01

    This paper describes the current status of real-time digital plasma control for the DIII-D tokamak. The digital plasma control system (PCS) has been in place at DIII-D since the early 1990s and continues to expand and improve in its capabilities to monitor and control plasma parameters for DIII-D fusion science experiments. The PCs monitors over 200 tokamak parameters from the DIII-D experiment using a real-time data acquisition system that acquires a new set of samples once every 60 micros. This information is then used in a number of feedback control algorithms to compute and control a variety of parameters including those affecting plasma shape and position. A number of system related improvements has improved the usability and flexibility of the DIII-D PCS. These include more graphical user interfaces to assist in entering and viewing the large and ever growing number of parameters controlled by the PCS, increased interaction and accessibility from other DIII-D applications, and upgrades to the computer hardware and vended software. Future plans for the system include possible upgrades of the real-time computers, further links to other DIII-D diagnostic measurements such as real-time Thomson scattering analysis, and joint collaborations with other tokamak experiments including the NSTX at Princeton

  9. Plasmas in Multiphase Media: Bubble Enhanced Discharges in Liquids and Plasma/Liquid Phase Boundaries

    Energy Technology Data Exchange (ETDEWEB)

    Kushner, Mark Jay [University of Michigan

    2014-07-10

    In this research project, the interaction of atmospheric pressure plasmas with multi-phase media was computationally investigated. Multi-phase media includes liquids, particles, complex materials and porous surfaces. Although this investigation addressed fundamental plasma transport and chemical processes, the outcomes directly and beneficially affected applications including biotechnology, medicine and environmental remediation (e.g., water purification). During this project, we made advances in our understanding of the interaction of atmospheric pressure plasmas in the form of dielectric barrier discharges and plasma jets with organic materials and liquids. We also made advances in our ability to use computer modeling to represent these complex processes. We determined the method that atmospheric pressure plasmas flow along solid and liquid surfaces, and through endoscopic like tubes, deliver optical and high energy ion activation energy to organic and liquid surfaces, and produce reactivity in thin liquid layers, as might cover a wound. We determined the mechanisms whereby plasmas can deliver activation energy to the inside of liquids by sustaining plasmas in bubbles. These findings are important to the advancement of new technology areas such as plasma medicine

  10. Spectroscopic analysis of coal plasma emission produced by laser ablation

    OpenAIRE

    Vera-Londoño, Liliana Patricia; Pérez-Taborda, Jaime Andrés; Riascos-Landázuri, Henry

    2016-01-01

    An analysis of plasma produced by laser ablation using 1,064 nm of laser radiation from a Q-switched Nd:YAG on coal mineral samples under air ambient, was performed. The emission of molecular band systems such as C2 Swan System , the First Negative System N2 (Band head at 501.53 nm) and different emission lines were investigated using the optical emission spectroscopy technique. The C2 molecular spectra (Swan band) were analyzed to determine vibrational temperature (0.62 eV). The density and ...

  11. Applied plasma physics

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Applied Plasma Physics is a major sub-organizational unit of the MFE Program. It includes Fusion Plasma Theory and Experimental Plasma Research. The Fusion Plasma Theory group has the responsibility for developing theoretical-computational models in the general areas of plasma properties, equilibrium, stability, transport, and atomic physics. This group has responsibility for giving guidance to the mirror experimental program. There is a formal division of the group into theory and computational; however, in this report the efforts of the two areas are not separated since many projects have contributions from members of both. Under the Experimental Plasma Research Program, we are developing the intense, pulsed neutral-beam source (IPINS) for the generation of a reversed-field configuration on 2XIIB. We are also studying the feasibility of utilizing certain neutron-detection techniques as plasma diagnostics in the next generation of thermonuclear experiments

  12. Physiological adaptation of maternal plasma volume during pregnancy: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Haas, S.; Ghossein-Doha, C.; Kuijk, S.M. van; Drongelen, J. van; Spaanderman, M.E.A.

    2017-01-01

    OBJECTIVE: To describe the physiological pattern of gestational plasma volume adjustments in normal singleton pregnancy and compare this with the pattern in pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction. METHODS: We performed a meta-analysis of

  13. The plasma universe

    International Nuclear Information System (INIS)

    Faelthammar, C.G.

    1989-12-01

    The term 'Plasma Universe', coined by Hannes Alfven, emphasices the fact that plasma phenomena discovered in the laboratory and in accessible regions of space. must be important also in the rest of the universe, which consists almost entirely of matter in the plasma state. Relevant aspect of this concept will be discussed. They include the response of the plasma to electric currents, the support of magnetic-field aligned electric fields, violation of the frozen-field condition, rapid release of magnetically stored energy, acceleration of charged particles, chemical separation, and filamentary and cellular structures. (authors)

  14. Advanced transport modeling of toroidal plasmas with transport barriers

    International Nuclear Information System (INIS)

    Fukuyama, A.; Murakami, S.; Honda, M.; Izumi, Y.; Yagi, M.; Nakajima, N.; Nakamura, Y.; Ozeki, T.

    2005-01-01

    Transport modeling of toroidal plasmas is one of the most important issue to predict time evolution of burning plasmas and to develop control schemes in reactor plasmas. In order to describe the plasma rotation and rapid transition self-consistently, we have developed an advanced scheme of transport modeling based on dynamical transport equation and applied it to the analysis of transport barrier formation. First we propose a new transport model and examine its behavior by the use of conventional diffusive transport equation. This model includes the electrostatic toroidal ITG mode and the electromagnetic ballooning mode and successfully describes the formation of internal transport barriers. Then the dynamical transport equation is introduced to describe the plasma rotation and the radial electric field self-consistently. The formation of edge transport barriers is systematically studied and compared with experimental observations. The possibility of kinetic transport modeling in velocity space is also examined. Finally the modular structure of integrated modeling code for tokamaks and helical systems is discussed. (author)

  15. Linear MHD stability analysis of post-disruption plasmas in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Aleynikova, K., E-mail: ksenia.aleynikova@gmail.com [EURATOM Association, Max-Planck-Institut für Plasmaphysik (Germany); Huijsmans, G. T. A. [ITER Organization (France); Aleynikov, P. [EURATOM Association, Max-Planck-Institut für Plasmaphysik (Germany)

    2016-05-15

    Most of the plasma current can be replaced by a runaway electron (RE) current during plasma disruptions in ITER. In this case the post-disruption plasma current profile is likely to be more peaked than the pre-disruption profile. The MHD activity of such plasma will affect the runaway electron generation and confinement and the dynamics of the plasma position evolution (Vertical Displacement Event), limiting the timeframe for runaway electrons and disruption mitigation. In the present paper, we evaluate the influence of the possible RE seed current parameters on the onset of the MHD instabilities. By varying the RE seed current profile, we search for subsequent plasma evolutions with the highest and the lowest MHD activity. This information can be applied to a development of desirable ITER disruption scenario.

  16. Bispectral analysis of nonlinear compressional waves in a two-dimensional dusty plasma crystal

    International Nuclear Information System (INIS)

    Nosenko, V.; Goree, J.; Skiff, F.

    2006-01-01

    Bispectral analysis was used to study the nonlinear interaction of compressional waves in a two-dimensional strongly coupled dusty plasma. A monolayer of highly charged polymer microspheres was suspended in a plasma sheath. The microspheres interacted with a Yukawa potential and formed a triangular lattice. Two sinusoidal pump waves with different frequencies were excited in the lattice by pushing the particles with modulated Ar + laser beams. Coherent nonlinear interaction of the pump waves was shown to be the mechanism of generating waves at the sum, difference, and other combination frequencies. However, coherent nonlinear interaction was ruled out for certain combination frequencies, in particular, for the difference frequency below an excitation-power threshold, as predicted by theory

  17. Implosive Thermal Plasma Source for Energy Conversion

    Czech Academy of Sciences Publication Activity Database

    Šonský, Jiří; Tesař, Václav; Gruber, Jan; Mašláni, Alan

    2017-01-01

    Roč. 4, č. 1 (2017), s. 87-90 ISSN 2336-2626 Institutional support: RVO:61388998 ; RVO:61389021 Keywords : implosion * thermal plasma * detonation wave Subject RIV: BL - Plasma and Gas Discharge Physics; BL - Plasma and Gas Discharge Physics (UFP-V) OBOR OECD: Fluids and plasma physics (including surface physics); Fluids and plasma physics (including surface physics) (UFP-V) https://ppt.fel.cvut.cz/ppt2017.html#number1

  18. Topical Conference on High Temperature Plasma Diagnostics, 7th, Napa, CA, Mar. 13-17, 1988, Proceedings

    International Nuclear Information System (INIS)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1988-01-01

    Various papers concerning scientific instruments are presented. The general topics addressed include: laser scattering and optical diagnostics, collective scattering and interferometry, millimeter wave and current profile measurements, particle-based diagnostics, data acquisition and analysis, X-ray diagnostics, and particle- and photon-based diagnostics. Individual subjects discussed include: atomic hydrogen density measurements in an ion source plasma using VUV absorption spectrometer, resonant diagnostics of laser-produced Ba plasmas, radiative and diffusional effects to the population densities of the excited-state atoms in hydrogen plasma, and Watt-level millimeter-wave monolithic diode-grid frequency multipliers

  19. Simultaneous analysis of amphetamine-type stimulants in plasma by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Mariotti, Kristiane de Cássia; Schuh, Roselena S; Ferranti, Priscila; Ortiz, Rafael S; Souza, Daniele Z; Pechansky, Flavio; Froehlich, Pedro E; Limberger, Renata P

    2014-09-01

    Brazil is considered one of the countries with the highest number of amphetamine-type stimulant (ATS) users worldwide, mainly diethylpropion (DIE) and fenproporex (FEN). The use of ATS is mostly linked to diverted prescription stimulants and this misuse is widely associated with (ab)use by drivers. A validated method was developed for the simultaneous analysis of amphetamine (AMP), DIE and FEN in plasma samples employing direct immersion-solid-phase microextraction, and gas chromatographic/mass spectrometric analysis. Trichloroacetic acid 10% was used for plasma deproteinization. In situ derivatization with propylchloroformate was employed. The linear range of the method covered from 5.0 to 100 ng/mL. The detection limits were 1.0 (AMP), 1.5 (DIE) and 2.0 ng/mL (FEN). The accuracy assessment of the control samples was within 85.58-108.33% of the target plasma concentrations. Recoveries ranged from 46.35 to 84.46% and precision was <15% of the value of relative standard deviation. This method is appropriate for screening and confirmation in plasma forensic toxicology analyses of these basic drugs. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Correlation measurements for fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.

    1995-01-01

    A list of a few methods for plasma diagnostics via fluctuations (noise) analysis of random (both temporally and spatially) system parameters is reviewed. Analogy is drawn with certain noise analysis methods, used in the diagnostics of fission reactors. These methods have been applied also to fusion measurements to some extent. However, the treatment of fusion plasma fluctuations is dominated by an approach that allows for temporal randomness, but assumes periodicity in space. This approach suits well a large class of phenomena such as magnetic fluctuations (MHD effects), but is much less suited to treat localised effects such as turbulence and density fluctuations. This paper discusses the potentials of the former approach, i.e. ordinary noise analysis methods of non-periodic variables in fusion plasma diagnostics. A new recommendation is to use the crossed beam correlation analysis of soft X-ray signals for determining the local short-range correlations in the plasma and to perform a systematic exploration of the plasma spatial correlation structure with that and other methods. 16 refs, 7 figs

  1. Long-term heat stress induces the inflammatory response in dairy cows revealed by plasma proteome analysis.

    Science.gov (United States)

    Min, Li; Zheng, Nan; Zhao, Shengguo; Cheng, Jianbo; Yang, Yongxin; Zhang, Yangdong; Yang, Hongjian; Wang, Jiaqi

    2016-03-04

    In this work we employed a comparative proteomic approach to evaluate seasonal heat stress and investigate proteomic alterations in plasma of dairy cows. Twelve lactating Holstein dairy cows were used and the treatments were: heat stress (n = 6) in hot summer (at the beginning of the moderate heat stress) and no heat stress (n = 6) in spring natural ambient environment, respectively. Subsequently, heat stress treatment lasted 23 days (at the end of the moderate heat stress) to investigate the alterations of plasma proteins, which might be employed as long-term moderate heat stress response in dairy cows. Changes in plasma proteins were analyzed by two-dimensional electrophoresis (2-DE) combined with mass spectrometry. Analysis of the properties of the identified proteins revealed that the alterations of plasma proteins were related to inflammation in long-term moderate heat stress. Furthermore, the increase in plasma tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6) directly demonstrated that long-term moderate heat stress caused an inflammatory response in dairy cows. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Evaluation of radioimmunological methods for assay of plasma and urinary aldosterone

    International Nuclear Information System (INIS)

    Pakarinen, A.; Koskinen, L.; Adlercreutz, H.

    1976-01-01

    Two radioimmunological methods for assay of plasma and urinary aldosterone were carefully evaluated. In the plasma method a radioimmunoassay is preceded by chromatography on a Sephadex LH-20 column. The method for urine includes a preextraction, hydrolysis of the acid-labile conjugates of aldosterone, and a radioimmunoassay. Both methods fulfill the criteria of reliability and are suitable for both routine and demanding research assays. The plasma method, using columns of double length is also applicable to analysis of aldosterone on plasma of newborn children, and pregnant females and in cord plasma. The concentration of plasma aldosterone in healthy subjects on an ad lib salt diet was 162 π+ 93 (S.D.) pmol/l in the supine position and 312 π+ 217 (S.D.) pmol/l upright. The urinary excretion of aldosterone in healthy subjects was 28.3 π+ 16.7 (S.D.) nmol/24 h. (Auth.)

  3. Plasma level of brain-derived neurotrophic factor and the related analysis in depressive patients with suicide attempt

    Institute of Scientific and Technical Information of China (English)

    操军

    2014-01-01

    Objective To explore the association between brainderived neurotrophic factor(BDNF)and suicidal behavior through analyzing and detecting the alteration of plasma BDNF level in depressive patients with suicide attempt.Methods Using enzyme-linked immunosorbent analysis(ELISA)to test the plasma level of BDNF in 27suicidal depressed patients,33 non-suicidal depressed patients and 30 normal controls.Meanwhile,the Hamilton Depression Scale(HAMD)and Beck

  4. Applied plasma physics

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Applied Plasma Physics is a major sub-organizational unit of the Magnetic Fusion Energy (MFE) Program. It includes Fusion Plasma Theory and Experimental Plasma Research. The Fusion Plasma Theory group has the responsibility for developing theoretical-computational models in the general areas of plasma properties, equilibrium, stability, transport, and atomic physics. This group has responsibility for giving guidance to the mirror experimental program. There is a formal division of the group into theory and computational; however, in this report the efforts of the two areas are not separated since many projects have contributions from members of both. Under the Experimental Plasma Research Program we are developing a neutral-beam source, the intense, pulsed ion-neutral source (IPINS), for the generation of a reversed-field configuration on 2XIIB. We are also studying the feasibility of using certain neutron-detection techniques as plasma diagnostics in the next generation of thermonuclear experiments

  5. First trimesters Pregnancy-Associated Plasma Protein-A levels value to Predict Gestational diabetes Mellitus: A systematic review and meta-analysis of the literature.

    Science.gov (United States)

    Talasaz, Zahra Hadizadeh; Sadeghi, Ramin; Askari, Fariba; Dadgar, Salmeh; Vatanchi, Atiyeh

    2018-04-01

    Detecting pregnant women at risk of diabetes in first months can help them by early intervention for delaying or preventing onset of GDM. In this study, we aimed to assess the Predictive value of first trimester Pregnancy related plasma protein-A (PAPP-A) levels for detecting Gestational diabetes Mellitus (GDM). This systematic review and meta-analysis was conducted through probing in databases. PubMed, Scopus, Medline and Google scholar citations were searched to find the published papers from 1974 to 2017. Studies were considered eligible if they were cohorts, case-control studies, reported GDM result, not other types, conducted on singleton pregnancy, measured Serum pregnancy associated plasma protein A in the first trimester and evaluated the relation of first trimester pregnancy associated plasma protein-A and GDM. Two reviewers independently assessed the quality with Newcastle-Ottawa and extracted data in the Pre-defined checklist. Analysis of the data was carried out by "Comprehensive Meta-analysis Version 2 (CAM)" and Metadisc software. 17 articles have our inclusion criteria and were considered in our systematic review, 5 studies included in Meta-analysis. Meta-analysis of these articles showed that the predictive value of PAPP-A for GDM has 55% sensitivity (53-58), 90% (89-90) specificity, LR + 2.48 (0.83-7.36) and LR - 0.70 (0.45-1.09) with 95% confidence intervals. In our study PAPP-A has low predictive accuracy overall, but it may be useful when combined with other tests, and this is an active part for future research. One limitation of our study is significant heterogeneity because of different adjusted variables and varied diagnostic criteria. Copyright © 2018. Published by Elsevier B.V.

  6. Time-frequency analysis of non-stationary fusion plasma signals using an improved Hilbert-Huang transform

    International Nuclear Information System (INIS)

    Liu, Yangqing; Tan, Yi; Xie, Huiqiao; Wang, Wenhao; Gao, Zhe

    2014-01-01

    An improved Hilbert-Huang transform method is developed to the time-frequency analysis of non-stationary signals in tokamak plasmas. Maximal overlap discrete wavelet packet transform rather than wavelet packet transform is proposed as a preprocessor to decompose a signal into various narrow-band components. Then, a correlation coefficient based selection method is utilized to eliminate the irrelevant intrinsic mode functions obtained from empirical mode decomposition of those narrow-band components. Subsequently, a time varying vector autoregressive moving average model instead of Hilbert spectral analysis is performed to compute the Hilbert spectrum, i.e., a three-dimensional time-frequency distribution of the signal. The feasibility and effectiveness of the improved Hilbert-Huang transform method is demonstrated by analyzing a non-stationary simulated signal and actual experimental signals in fusion plasmas

  7. Spectrum analysis of hydrogen plasma in spherically convergent beam fusion

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, Kazuki; Yamauchi, Kunihito; Watanabe, Masato; Sunaga, Yoshitaka; Hotta, Eiki [Tokyo Institute of Technology, Dept. of Energy Sciences, Yokohama, Kanagawa (Japan); Okino, Akitoshi [Tokyo Institute of Technology, Dept. of Electrical and Electronic Engineering, Tokyo (Japan)

    2001-09-01

    Spectroscopic analysis of spherical glow discharge fusion device was carried out using hydrogen gas. Effects of the discharge current and cathode voltage on spectrum profiles of hydrogen Balmar lines were measured. The profiles of all hydrogen lines were broadened with the cathode voltage. From the relationship between the maximum broadening width and the cathode voltage, it was indicated that the broadening was caused by the Doppler effect. From the spatial distribution of emission intensity, it was found that plasma core size became larger with discharge current and smaller with cathode voltage. (author)

  8. Spectrum analysis of hydrogen plasma in spherically convergent beam fusion

    International Nuclear Information System (INIS)

    Ogasawara, Kazuki; Yamauchi, Kunihito; Watanabe, Masato; Sunaga, Yoshitaka; Hotta, Eiki; Okino, Akitoshi

    2001-01-01

    Spectroscopic analysis of spherical glow discharge fusion device was carried out using hydrogen gas. Effects of the discharge current and cathode voltage on spectrum profiles of hydrogen Balmar lines were measured. The profiles of all hydrogen lines were broadened with the cathode voltage. From the relationship between the maximum broadening width and the cathode voltage, it was indicated that the broadening was caused by the Doppler effect. From the spatial distribution of emission intensity, it was found that plasma core size became larger with discharge current and smaller with cathode voltage. (author)

  9. Thought analysis on self-organization theories of MHD plasma

    International Nuclear Information System (INIS)

    Kondoh, Yoshiomi; Sato, Tetsuya.

    1992-08-01

    A thought analysis on the self-organization theories of dissipative MHD plasma is presented to lead to three groups of theories that lead to the same relaxed state of ∇ x B = λB, in order to find an essential physical picture embedded in the self-organization phenomena due to nonlinear and dissipative processes. The self-organized relaxed state due to the dissipation by the Ohm loss is shown to be formulated generally as the state such that yields the minimum dissipation rate of global auto-and/or cross-correlations between two quantities in j, B, and A for their own instantaneous values of the global correlations. (author)

  10. Relaxation with high-speed plasma flows and singularity analysis in MHD equilibrium

    International Nuclear Information System (INIS)

    Shiraishi, Junya; Ohsaki, Shuichi; Yoshida, Zensho

    2004-01-01

    Relaxation model that leads to plasma confinement with rigid-rotation is presented. This model applies to Jupiter's magnetosphere. It is shown that the invariance of canonical angular momentum of electron fluid, which is realized by axisymmetry through self-organization process, yields plasma confinement. including poloidal flows in equilibrium equation makes the problem rather complicated. Singularity due to the poloidal flow is focused on. It is shown that the singular equation for equilibrium has the same structure as the equation for linear Alfven wave. Since the singular solution for equilibrium equation is physically inadequate, the singularity may be removed by another physical effect. The Hall-effect is taken into account as a singular perturbation that removes the singularity of equilibrium equation for ideal magnetohydrodynamics. (author)

  11. Comparing transfusion reaction rates for various plasma types: a systematic review and meta-analysis/regression.

    Science.gov (United States)

    Saadah, Nicholas H; van Hout, Fabienne M A; Schipperus, Martin R; le Cessie, Saskia; Middelburg, Rutger A; Wiersum-Osselton, Johanna C; van der Bom, Johanna G

    2017-09-01

    We estimated rates for common plasma-associated transfusion reactions and compared reported rates for various plasma types. We performed a systematic review and meta-analysis of peer-reviewed articles that reported plasma transfusion reaction rates. Random-effects pooled rates were calculated and compared between plasma types. Meta-regression was used to compare various plasma types with regard to their reported plasma transfusion reaction rates. Forty-eight studies reported transfusion reaction rates for fresh-frozen plasma (FFP; mixed-sex and male-only), amotosalen INTERCEPT FFP, methylene blue-treated FFP, and solvent/detergent-treated pooled plasma. Random-effects pooled average rates for FFP were: allergic reactions, 92/10 5 units transfused (95% confidence interval [CI], 46-184/10 5 units transfused); febrile nonhemolytic transfusion reactions (FNHTRs), 12/10 5 units transfused (95% CI, 7-22/10 5 units transfused); transfusion-associated circulatory overload (TACO), 6/10 5 units transfused (95% CI, 1-30/10 5 units transfused); transfusion-related acute lung injury (TRALI), 1.8/10 5 units transfused (95% CI, 1.2-2.7/10 5 units transfused); and anaphylactic reactions, 0.8/10 5 units transfused (95% CI, 0-45.7/10 5 units transfused). Risk differences between plasma types were not significant for allergic reactions, TACO, or anaphylactic reactions. Methylene blue-treated FFP led to fewer FNHTRs than FFP (risk difference = -15.3 FNHTRs/10 5 units transfused; 95% CI, -24.7 to -7.1 reactions/10 5 units transfused); and male-only FFP led to fewer cases of TRALI than mixed-sex FFP (risk difference = -0.74 TRALI/10 5 units transfused; 95% CI, -2.42 to -0.42 injuries/10 5 units transfused). Meta-regression demonstrates that the rate of FNHTRs is lower for methylene blue-treated compared with FFP, and the rate of TRALI is lower for male-only than for mixed-sex FFP; whereas no significant differences are observed between plasma types for allergic reactions, TACO

  12. Magnetospheric plasma waves

    International Nuclear Information System (INIS)

    Shawhan, S.D.

    1977-01-01

    A brief history of plasma wave observations in the Earth's magnetosphere is recounted and a classification of the identified plasma wave phenomena is presented. The existence of plasma waves is discussed in terms of the characteristic frequencies of the plasma, the energetic particle populations and the proposed generation mechanisms. Examples are given for which plasmas waves have provided information about the plasma parameters and particle characteristics once a reasonable theory has been developed. Observational evidence and arguments by analogy to the observed Earth plasma wave processes are used to identify plasma waves that may be significant in other planetary magnetospheres. The similarities between the observed characteristics of the terrestrial kilometric radiation and radio bursts from Jupiter, Saturn and possibly Uranus are stressed. Important scientific problems concerning plasma wave processes in the solar system and beyond are identified and discussed. Models for solar flares, flare star radio outbursts and pulsars include elements which are also common to the models for magnetospheric radio bursts. Finally, a listing of the research and development in terms of instruments, missions, laboratory experiments, theory and computer simulations needed to make meaningful progress on the outstanding scientific problems of plasma wave research is given. (Auth.)

  13. Negative ion surface plasma source development for plasma trap injectors in Novosibirsk

    International Nuclear Information System (INIS)

    Bel'chenko, Yu.I.; Dimov, G.I.; Dudnikov, V.G.; Kupriyanov, A.S.

    1989-01-01

    Work on high-current ion sources carried out at the Novosibirsk Institute of Nuclear Physics (INP) is presented. The INP investigations on ''pure plasma'' planotron and ''pure surface'' secondary emission systems of H - generation, which preceded the surface-plasma concept developed in Novosibirsk, are described. The physical basis of the surface-plasma method of negative-ion production is considered. The versions and operating characteristics of different surface-plasma sources including the multi-ampere (approx-gt 10A) source are discussed. Research on efficient large-area (∼10 2 cm 2 ) negative ion surface-plasma emitters is described. The INP long-pulse multiaperture surface- plasma generators, with a current of about 1A, are described. 38 refs., 17 figs

  14. Quantitative analysis of self-association and mobility of annexin A4 at the plasma membrane.

    Science.gov (United States)

    Crosby, Kevin C; Postma, Marten; Hink, Mark A; Zeelenberg, Christiaan H C; Adjobo-Hermans, Merel J W; Gadella, Theodorus W J

    2013-05-07

    Annexins, found in most eukaryotic species, are cytosolic proteins that are able to bind negatively-charged phospholipids in a calcium-dependent manner. Annexin A4 (AnxA4) has been implicated in diverse cellular processes, including the regulation of exocytosis and ion-transport; however, its precise mechanistic role is not fully understood. AnxA4 has been shown to aggregate on lipid layers upon Ca(2+) binding in vitro, a characteristic that may be critical for its function. We have utilized advanced fluorescence microscopy to discern details on the mobility and self-assembly of AnxA4 after Ca(2+) influx at the plasma membrane in living cells. Total internal reflection microscopy in combination with Förster resonance energy transfer reveals that there is a delay between initial plasma membrane binding and the beginning of self-assembly and this process continues after the cytoplasmic pool has completely relocated. Number-and-brightness analysis suggests that the predominant membrane bound mobile form of the protein is trimeric. There also exists a pool of AnxA4 that forms highly immobile aggregates at the membrane. Fluorescence recovery after photobleaching suggests that the relative proportion of these two forms varies and is correlated with membrane morphology. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  15. Applications of Symmetry Methods to the Theory of Plasma Physics

    Directory of Open Access Journals (Sweden)

    Giampaolo Cicogna

    2006-02-01

    Full Text Available The theory of plasma physics offers a number of nontrivial examples of partial differential equations, which can be successfully treated with symmetry methods. We propose three different examples which may illustrate the reciprocal advantage of this "interaction" between plasma physics and symmetry techniques. The examples include, in particular, the complete symmetry analysis of system of two PDE's, with the determination of some conditional and partial symmetries, the construction of group-invariant solutions, and the symmetry classification of a nonlinear PDE.

  16. Nonlinear Plasma Waves Excitation by Intense Ion Beams in Background Plasma

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.; Startsev, Edward A.; Davidson, Ronald C.

    2004-01-01

    Plasma neutralization of an intense ion pulse is of interest for many applications, including plasma lenses, heavy ion fusion, cosmic ray propagation, etc. An analytical electron fluid model has been developed to describe the plasma response to a propagating ion beam. The model predicts very good charge neutralization during quasi-steady-state propagation, provided the beam pulse duration τ b is much longer than the electron plasma period 2π/ω p , where ω p = (4πe 2 n p /m) 1/2 is the electron plasma frequency and n p is the background plasma density. In the opposite limit, the beam pulse excites large-amplitude plasma waves. If the beam density is larger than the background plasma density, the plasma waves break. Theoretical predictions are compared with the results of calculations utilizing a particle-in-cell (PIC) code. The cold electron fluid results agree well with the PIC simulations for ion beam propagation through a background plasma. The reduced fluid description derived in this paper can provide an important benchmark for numerical codes and yield scaling relations for different beam and plasma parameters. The visualization of numerical simulation data shows complex collective phenomena during beam entry and exit from the plasma

  17. Nonlinear plasma waves excitation by intense ion beams in background plasma

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.; Startsev, Edward A.; Davidson, Ronald C.

    2004-01-01

    Plasma neutralization of an intense ion pulse is of interest for many applications, including plasma lenses, heavy ion fusion, cosmic ray propagation, etc. An analytical electron fluid model has been developed to describe the plasma response to a propagating ion beam. The model predicts very good charge neutralization during quasi-steady-state propagation, provided the beam pulse duration τ b is much longer than the electron plasma period 2π/ω p , where ω p =(4πe 2 n p /m) 1/2 is the electron plasma frequency, and n p is the background plasma density. In the opposite limit, the beam pulse excites large-amplitude plasma waves. If the beam density is larger than the background plasma density, the plasma waves break. Theoretical predictions are compared with the results of calculations utilizing a particle-in-cell (PIC) code. The cold electron fluid results agree well with the PIC simulations for ion beam propagation through a background plasma. The reduced fluid description derived in this paper can provide an important benchmark for numerical codes and yield scaling relations for different beam and plasma parameters. The visualization of numerical simulation data shows complex collective phenomena during beam entry and exit from the plasma

  18. Studies of the ablated plasma from experimental plasma gun disruption simulations

    International Nuclear Information System (INIS)

    Rockett, P.D.; Hunter, J.A.; Bradley, J.T. III; Gahl, J.M.; Litunovsky, V.N.; Ovchinnokov, I.B.; Ljublin, B.V.; Kuznetsov, B.E.; Titov, V.A.; Zhitlukhin, A.; Arkhipov, K.; Bakhtin, V.; Toporkov, D.

    1995-01-01

    Extensive simulations of tokamak disruptions have provided a picture of material erosion that is limited by the transfer of energy from the incident plasma to the armor solid surface through a dense plasma shield. Radiation spectra were recorded in the VUV and in the visible at the Efremov Laboratories on VIKA using graphite targets. The VUV data were recorded with a Sandia Labs transmission grating spectrograph, covering 1-40 nm. Plasma parameters were evaluated with incident plasma energy densities varying from 10-100 MJ/m 2 . A second transmission grating spectrograph was taken to 2MK-200 at TRINITI to study the plasma-material interface in magnetic cusp plasma. Target materials included POCO graphite, ATJ graphite, boron nitride, and plasma-sprayed tungsten. Detailed spectra were recorded with a spatial resolution of similar 1 mm. Time-resolved data with 40-200 ns resolution was also recorded. The data from both plasma gun facilities demonstrated that the hottest plasma region was sitting several millimeters above the armor tile surface. ((orig.))

  19. Higher order structure analysis of nano-materials by spectral reflectance of laser-plasma soft x-ray

    International Nuclear Information System (INIS)

    Azuma, Hirozumi; Takeichi, Akihiro; Noda, Shoji

    1995-01-01

    We have proposed a new experimental arrangement to measure spectral reflectance of nano-materials for analyzing higher order structure with laser-plasma soft x-rays. Structure modification of annealed Mo/Si multilayers and a nylon-6/clay hybrid with poor periodicity was investigated. The measurement of the spectral reflectance of soft x-rays from laser-produced plasma was found to be a useful method for the structure analysis of nano-materials, especially those of rather poor periodicity

  20. Survey of Galileo Plasma Observations in Jupiter's Plasma Sheet

    Science.gov (United States)

    Bagenal, Fran; Wilson, Robert J.; Siler, Scott; Paterson, William R.; Kurth, William S.

    2016-01-01

    The plasma science (PLS) Instrument on the Galileo spacecraft (orbiting Jupiter from December 1995 to September 2003) measured properties of the ions that were trapped in the magnetic field. The PLS data provide a survey of the plasma properties between approx. 5 and 30 Jupiter radii [R(sub J)] in the equatorial region. We present plasma properties derived via two analysis methods: numerical moments and forward modeling. We find that the density decreases with radial distance by nearly 5 orders of magnitude from approx. 2 to 3000 cm(exp.-3) at 6R(sub j) to approx. 0.05cm(sub -3) at 30 R(sub j). The density profile did not show major changes from orbit to orbit, suggesting that the plasma production and transport remained constant within about a factor of 2. The radial profile of ion temperature increased with distance which implied that contrary to the concept of adiabatic cooling on expansion, the plasma heats up as it expands out from Io's orbit (where TI is approx.60-80 eV) at approx. 6R(sub j) to a few keV at 30R(sub j).There does not seem to be a long-term, systematic variation in ion temperature with either local time or longitude. This latter finding differs from earlier analysis of Galileo PLS data from a selection of orbits. Further examination of all data from all Galileo orbits suggests that System Ill variations are transitory on timescales of weeks, consistent with the modeling of Cassini Ultraviolet Imaging Spectrograph observations. The plasma flow is dominated by azimuthal flow that is between 80% and 100% of corotation out to 25 R(sub j).

  1. Analysis of processes in DC arc plasma torches for spraying that use air as plasma forming gas

    International Nuclear Information System (INIS)

    Frolov, V; Ivanov, D; Toropchin, A

    2014-01-01

    Developed in Saint Petersburg State Polytechnical University technological processes of air-plasma spraying of wear-resistant, regenerating, hardening and decorative coatings used in number of industrial areas are described. The article contains examples of applications of air plasma spraying of coatings as well as results of mathematical modelling of processes in air plasma torches for spraying

  2. Spectra of heliumlike krypton from tokamak fusion test reactor plasmas

    International Nuclear Information System (INIS)

    Bitter, M.; Hsuan, H.; Bush, C.; Cohen, S.; Cummings, C.J.; Grek, B.; Hill, K.W.; Schivell, J.; Zarnstorff, M.; Smith, A.; Fraenkel, B.

    1993-04-01

    Krypton has been injected into ohmically-heated TFTR plasmas with peak electron temperatures of 6 key to study the effects of krypton on the plasma performance and to investigate the emitted krypton line radiation, which is of interest for future-generation tokamaks such as ITER, both as a diagnostic of the central ion temperature and for the control of energy release from the plasma by radiative cooling. The emitted radiation was monitored with a bolometer array, an X-ray pulse height analysis system, and a high-resolution Johann-type crystal spectrometer; and it was found to depend very sensitively on the electron temperature profile. Satellite spectra of heliumlike krypton, KrXXXV, near 0.95 Angstrom including lithiumlike, berylliumlike and boronlike features were recorded in second order Bragg reflection. Radiative cooling and reduced particle recycling at the plasma edge region were observed as a result of the krypton injection for all investigated discharges. The observations are in reasonable agreement with modeling calculations of the krypton ion charge state distribution including radial transport

  3. Communication through a plasma sheet around a fast moving vehicle

    Science.gov (United States)

    Sotnikov, V. I.; Mudaliar, S.; Genoni, T.; Rose, D.; Oliver, B. V.; Mehlhorn, T. A.

    2011-10-01

    Investigation of the complicated problem of scattering of electromagnetic waves on turbulent pulsations induced by a sheared flow inside a plasma sheath is important for many applications including communication with hypersonic and re-entry vehicles. Theoretical and computational work aimed at improving the understanding of electromagnetic wave scattering processes in such turbulent plasmas is presented. We analyze excitation of low frequency ion-acoustic type oscillations in a compressible plasma flow with flow velocity shear and influence of such turbulent pulsations on scattering of high frequency electromagnetic waves used for communication purposes. We have appropriately included in our analysis the presence of electron and ion collisions with neutrals as well as electron - ion collisions. Results of numerical solutions for plasma density and electric field perturbations for different velocity profiles have been used in the derived expressions for scattered wave energy and scattering cross section. Work supported by the Air Force Research Laboratory and Air Force Office Of Scientific Research Sandia is a multiprogram laboratory operated by Sandia Corporation, A Lockheed Martin Company, under contract DE-AC04-94AL85000.

  4. Determination of GABA and vigabatrin in human plasma by a rapid and simple HPLC method: correlation between clinical response to vigabatrin and increase in plasma GABA.

    Science.gov (United States)

    Löscher, W; Fassbender, C P; Gram, L; Gramer, M; Hörstermann, D; Zahner, B; Stefan, H

    1993-03-01

    The novel antiepileptic drug vigabatrin (Sabril) acts by inhibiting degradation of the inhibitory neurotransmitter gamma-aminobutyric acid (GABA), increasing the GABA concentrations in the brain. Because the GABA degrading enzyme GABA aminotransferase (GABA-T) is also present in peripheral tissues, including blood platelets, measurement of plasma GABA levels might be a useful indication of the pharmacological response to vigabatrin during therapeutic monitoring. However, because of the very low concentrations of GABA in plasma, the few methods available for plasma GABA analysis are time-consuming, difficult to perform and/or not selective enough because of potential interference with other plasma constituents. In the present study, a rapid, selective and sensitive amino acid analysis HPLC method has been developed for plasma GABA determination with fluorescence detection, using o-phthaldialdehyde as a precolumn derivatizing agent. By employing a 3 microns particle size reversed-phase column and a multi-step gradient system of two solvents, the very low endogenous concentration of GABA in human plasma could be reproducibly quantitated without interference of other endogenous compounds. Incubation of human plasma samples with GABA degrading enzyme(s) resulted in an almost total loss of the GABA peak, thus demonstrating the specificity of the method for GABA analysis. In addition to GABA and other endogenous amino acids, the HPLC method could be used to quantitate plasma levels of vigabatrin. Thus, this improved HPLC amino acid assay might be used to examine whether concomitant monitoring of plasma GABA and vigabatrin is useful for clinical purposes. This was examined in 20 epileptic patients undergoing chronic treatment with vigabatrin. The average plasma GABA level of these 20 patients did not differ significantly from non-epileptic controls. However, when epileptic patients were subdivided according to their clinical response to vigabatrin, vigabatrin responders

  5. Nonlinear equilibrium in Tokamaks including convective terms and viscosity

    International Nuclear Information System (INIS)

    Martin, P.; Castro, E.; Puerta, J.

    2003-01-01

    MHD equilibrium in tokamaks becomes very complex, when the non-linear convective term and viscosity are included in the momentum equation. In order to simplify the analysis, each new term has been separated in type gradient terms and vorticity depending terms. For the special case in which the vorticity vanishes, an extended Grad-Shafranov type equation can be obtained. However now the magnetic surface is not isobars or current surfaces as in the usual Grad-Shafranov treatment. The non-linear convective terms introduces gradient of Bernoulli type kinetic terms . Montgomery and other authors have shown the importance of the viscosity terms in tokamaks [1,2], here the treatment is carried out for the equilibrium condition, including generalized tokamaks coordinates recently described [3], which simplify the equilibrium analysis. Calculation of the new isobar surfaces is difficult and some computation have been carried out elsewhere for some particular cases [3]. Here, our analysis is extended discussing how the toroidal current density, plasma pressure and toroidal field are modified across the midplane because of the new terms (convective and viscous). New calculations and computations are also presented. (Author)

  6. Integrated models for plasma/material interaction during loss of plasma confinement

    International Nuclear Information System (INIS)

    Hassanein, A.

    1998-01-01

    A comprehensive computer package, High Energy Interaction with General Heterogeneous Target Systems (HEIGHTS), has been developed to evaluate the damage incurred on plasma-facing materials during loss of plasma confinement. The HEIGHTS package consists of several integrated computer models that follow the start of a plasma disruption at the scrape-off layer (SOL) through the transport of the eroded debris and splashed target materials to nearby locations as a result of the energy deposited. The package includes new models to study turbulent plasma behavior in the SOL and predicts the plasma parameters and conditions at the divertor plate. Full two-dimensional comprehensive radiation magnetohydrodynamic models are coupled with target thermodynamics and liquid hydrodynamics to evaluate the integrated response of plasma-facing materials. A brief description of the HEIGHTS package and its capabilities are given in this work with emphasis on turbulent plasma behavior in the SOL during disruptions

  7. Clinical and Biological Predictors of Plasma Levels of Soluble RAGE in Critically Ill Patients: Secondary Analysis of a Prospective Multicenter Observational Study

    Directory of Open Access Journals (Sweden)

    Thibaut Pranal

    2018-01-01

    Full Text Available Rationale. Although soluble forms of the receptor for advanced glycation end products (RAGE have been recently proposed as biomarkers in multiple acute or chronic diseases, few studies evaluated the influence of usual clinical and biological parameters, or of patient characteristics and comorbidities, on circulating levels of soluble RAGE in the intensive care unit (ICU setting. Objectives. To determine, among clinical and biological parameters that are usually recorded upon ICU admission, which variables, if any, could be associated with plasma levels of soluble RAGE. Methods. Data for this ancillary study were prospectively obtained from adult patients with at least one ARDS risk factor upon ICU admission enrolled in a large multicenter observational study. At ICU admission, plasma levels of total soluble RAGE (sRAGE and endogenous secretory (esRAGE were measured by duplicate ELISA and baseline patient characteristics, comorbidities, and usual clinical and biological indices were recorded. After univariate analyses, significant variables were used in multivariate, multidimensional analyses. Measurements and Main Results. 294 patients were included in this ancillary study, among whom 62% were admitted for medical reasons, including septic shock (11%, coma (11%, and pneumonia (6%. Although some variables were associated with plasma levels of RAGE soluble forms in univariate analysis, multidimensional analyses showed no significant association between admission parameters and baseline plasma sRAGE or esRAGE. Conclusions. We found no obvious association between circulating levels of soluble RAGE and clinical and biological indices that are usually recorded upon ICU admission. This trial is registered with NCT02070536.

  8. Scale-free crystallization of two-dimensional complex plasmas: Domain analysis using Minkowski tensors

    Science.gov (United States)

    Böbel, A.; Knapek, C. A.; Räth, C.

    2018-05-01

    Experiments of the recrystallization processes in two-dimensional complex plasmas are analyzed to rigorously test a recently developed scale-free phase transition theory. The "fractal-domain-structure" (FDS) theory is based on the kinetic theory of Frenkel. It assumes the formation of homogeneous domains, separated by defect lines, during crystallization and a fractal relationship between domain area and boundary length. For the defect number fraction and system energy a scale-free power-law relation is predicted. The long-range scaling behavior of the bond-order correlation function shows clearly that the complex plasma phase transitions are not of the Kosterlitz, Thouless, Halperin, Nelson, and Young type. Previous preliminary results obtained by counting the number of dislocations and applying a bond-order metric for structural analysis are reproduced. These findings are supplemented by extending the use of the bond-order metric to measure the defect number fraction and furthermore applying state-of-the-art analysis methods, allowing a systematic testing of the FDS theory with unprecedented scrutiny: A morphological analysis of lattice structure is performed via Minkowski tensor methods. Minkowski tensors form a complete family of additive, motion covariant and continuous morphological measures that are sensitive to nonlinear properties. The FDS theory is rigorously confirmed and predictions of the theory are reproduced extremely well. The predicted scale-free power-law relation between defect fraction number and system energy is verified for one more order of magnitude at high energies compared to the inherently discontinuous bond-order metric. It is found that the fractal relation between crystalline domain area and circumference is independent of the experiment, the particular Minkowski tensor method, and the particular choice of parameters. Thus, the fractal relationship seems to be inherent to two-dimensional phase transitions in complex plasmas. Minkowski

  9. ITER plasma safety interface models and assessments

    International Nuclear Information System (INIS)

    Uckan, N.A.; Bartels, H-W.; Honda, T.; Amano, T.; Boucher, D.; Post, D.; Wesley, J.

    1996-01-01

    Physics models and requirements to be used as a basis for safety analysis studies are developed and physics results motivated by safety considerations are presented for the ITER design. Physics specifications are provided for enveloping plasma dynamic events for Category I (operational event), Category II (likely event), and Category III (unlikely event). A safety analysis code SAFALY has been developed to investigate plasma anomaly events. The plasma response to ex-vessel component failure and machine response to plasma transients are considered

  10. Comprehensive understandings of energy confinement in LHD plasmas through extensive application of the integrated transport analysis suite

    International Nuclear Information System (INIS)

    Yokoyama, M.; Seki, R.; Suzuki, C.; Ida, K.; Osakabe, M.; Satake, S.; Yamada, H.; Murakami, S.

    2014-10-01

    The integrated transport analysis suite, TASK3D-a, has enhanced energy transport analyses in LHD. It has clearly elucidated (1) the systematic dependence of ion and electron energy confinement on wide variation of plasma parameters, and (2) statistically-derived fitting expressions for the ion and electron heat diffusivities (χ i and χ e ), separately, taking also those radial-profile information into account. In particular, the latter approach can outstrip the conventional scaling laws for the global confinement time (τ E ) in terms of its considerations on profiles (temperature, density, heating depositions etc.). This has been made possible with the analysis database accumulated by the extensive application of the integrated transport analysis suite to experiment data. In this proceeding, TASK3D-a analysis-database for high-ion-temperature (high-T i ) plasmas in LHD (Large Helical Device) are exemplified. This approach should be applicable to any other combinations of integrated transport analysis suites and fusion experiments. (author)

  11. Analysis of the X-ray emission spectra of copper, germanium and rubidium plasmas produced at the Phelix laser facility

    Science.gov (United States)

    Comet, M.; Pain, J.-C.; Gilleron, F.; Piron, R.; Denis-Petit, D.; Méot, V.; Gosselin, G.; Morel, P.; Hannachi, F.; Gobet, F.; Tarisien, M.; Versteegen, M.

    2017-03-01

    We present the analysis of X-ray emission spectra of copper, germanium and rubidium plasmas measured at the Phelix laser facility. The laser intensity was around 6×1014 W.cm-2. The analysis is based on the hypothesis of an homogeneous plasma in local thermodynamic equilibrium using an effective temperature. This temperature is deduced from hydrodynamic simulations and collisional-radiative computations. Spectra are then calculated using the LTE opacity codes OPAMCDF and SCO-RCG and compared to experimental data.

  12. Preliminary scaling laws for plasma current, ion kinetic temperature, and plasma number density in the NASA Lewis bumpy torus plasma

    Science.gov (United States)

    Roth, J. R.

    1976-01-01

    Parametric variation of independent variables which may affect the characteristics of bumpy torus plasma have identified those which have a significant effect on the plasma current, ion kinetic temperature, and plasma number density, and those which do not. Empirical power law correlations of the plasma current, and the ion kinetic temperature and number density were obtained as functions of potential applied to the midplane electrode rings, the background neutral gas pressure, and the magnetic field strength. Additional parameters studied included the type of gas, the polarity of the midplane electrode rings, the mode of plasma operation, and the method of measuring the plasma number density. No significant departures from the scaling laws appear to occur at the highest ion kinetic temperatures or number densities obtained to date.

  13. Synthetic Aperture Microwave Imaging (SAMI) of the plasma edge on NSTX-U

    Science.gov (United States)

    Vann, Roddy; Taylor, Gary; Brunner, Jakob; Ellis, Bob; Thomas, David

    2016-10-01

    The Synthetic Aperture Microwave Imaging (SAMI) system is a unique phased-array microwave camera with a +/-40° field of view in both directions. It can image cut-off surfaces corresponding to frequencies in the range 10-34.5GHz; these surfaces are typically in the plasma edge. SAMI operates in two modes: either imaging thermal emission from the plasma (often modified by its interaction with the plasma edge e.g. via BXO mode conversion) or ``active probing'' i.e. injecting a broad beam at the plasma surface and imaging the reflected/back-scattered signal. SAMI was successfully pioneered on the Mega-Amp Spherical Tokamak (MAST) at Culham Centre for Fusion Energy. SAMI has now been installed and commissioned on the National Spherical Torus Experiment Upgrade (NSTX-U) at Princeton Plasma Physics Laboratory. The firmware has been upgraded to include real-time digital filtering, which enables continuous acquisition of the Doppler back-scattered active probing data. In this poster we shall present SAMI's analysis of the plasma edge on NSTX-U including measurements of the edge pitch angle on NSTX-U using SAMI's unique 2-D Doppler-backscattering capability.

  14. Real-time breath analysis with active capillary plasma ionization-ambient mass spectrometry.

    Science.gov (United States)

    Bregy, Lukas; Sinues, Pablo Martinez-Lozano; Nudnova, Maryia M; Zenobi, Renato

    2014-06-01

    On-line analysis of exhaled human breath is a growing area in analytical science, for applications such as fast and non-invasive medical diagnosis and monitoring. In this work, we present a novel approach based on ambient ionization of compounds in breath and subsequent real-time mass spectrometric analysis. We introduce a plasma ionization source for this purpose, which has no need for additional gases, is very small, and is easily interfaced with virtually any commercial atmospheric pressure ionization mass spectrometer (API-MS) without major modifications. If an API-MS instrument exists in a laboratory, the cost to implement this technology is only around [Formula: see text]500, far less than the investment for a specialized mass spectrometric system designed for volatile organic compounds (VOCs) analysis. In this proof-of-principle study we were able to measure mass spectra of exhaled human breath and found these to be comparable to spectra obtained with other electrospray-based methods. We detected over 100 VOCs, including relevant metabolites like fatty acids, with molecular weights extending up to 340 Da. In addition, we were able to monitor the time-dependent evolution of the peaks and show the enhancement of the metabolism after a meal. We conclude that this approach may complement current methods to analyze breath or other types of vapors, offering an affordable option to upgrade any pre-existing API-MS to a real-time breath analyzer.

  15. Pattern recognition in spaces of probability distributions for the analysis of edge-localized modes in tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Shabbir, Aqsa

    2016-07-07

    In this doctoral work, pattern recognition techniques are developed and applied to data from tokamak plasmas, in order to contribute to a systematic analysis of edge-localized modes (ELMs). We employ probabilistic models for a quantitative data description geared towards an enhanced systematization of ELM phenomenology. Hence, we start from the point of view that the fundamental object resulting from the observation of a system is a probability distribution, with every single measurement providing a sample from this distribution. In exploring the patterns emerging from the various ELM regimes and relations, we need methods that can handle the intrinsic probabilistic nature of the data. The original contributions of this work are twofold. First, several novel pattern recognition methods in non-Euclidean spaces of probability distribution functions (PDFs) are developed and validated. The second main contribution lies in the application of these and other techniques to a systematic analysis of ELMs in tokamak plasmas. In regard to the methodological aims of the work, we employ the framework of information geometry to develop pattern visualization and classification methods in spaces of probability distributions. In information geometry, a family of probability distributions is considered as a Riemannian manifold. Every point on the manifold represents a single PDF and the distribution parameters provide local coordinates on the manifold. The Fisher information plays the role of a Riemannian metric tensor, enabling calculation of geodesic curves on the surface. The length of such curves yields the geodesic distance (GD) on probabilistic manifolds, which is a natural similarity (distance) measure between PDFs. Equipped with a suitable distance measure, we extrapolate several distance-based pattern recognition methods to the manifold setting. This includes k-nearest neighbor (kNN) and conformal predictor (CP) methods for classification, as well as multidimensional

  16. Pattern recognition in spaces of probability distributions for the analysis of edge-localized modes in tokamak plasmas

    International Nuclear Information System (INIS)

    Shabbir, Aqsa

    2016-01-01

    In this doctoral work, pattern recognition techniques are developed and applied to data from tokamak plasmas, in order to contribute to a systematic analysis of edge-localized modes (ELMs). We employ probabilistic models for a quantitative data description geared towards an enhanced systematization of ELM phenomenology. Hence, we start from the point of view that the fundamental object resulting from the observation of a system is a probability distribution, with every single measurement providing a sample from this distribution. In exploring the patterns emerging from the various ELM regimes and relations, we need methods that can handle the intrinsic probabilistic nature of the data. The original contributions of this work are twofold. First, several novel pattern recognition methods in non-Euclidean spaces of probability distribution functions (PDFs) are developed and validated. The second main contribution lies in the application of these and other techniques to a systematic analysis of ELMs in tokamak plasmas. In regard to the methodological aims of the work, we employ the framework of information geometry to develop pattern visualization and classification methods in spaces of probability distributions. In information geometry, a family of probability distributions is considered as a Riemannian manifold. Every point on the manifold represents a single PDF and the distribution parameters provide local coordinates on the manifold. The Fisher information plays the role of a Riemannian metric tensor, enabling calculation of geodesic curves on the surface. The length of such curves yields the geodesic distance (GD) on probabilistic manifolds, which is a natural similarity (distance) measure between PDFs. Equipped with a suitable distance measure, we extrapolate several distance-based pattern recognition methods to the manifold setting. This includes k-nearest neighbor (kNN) and conformal predictor (CP) methods for classification, as well as multidimensional

  17. MAMP (microbe-associated molecular pattern)-induced changes in plasma membrane-associated proteins.

    Science.gov (United States)

    Uhlíková, Hana; Solanský, Martin; Hrdinová, Vendula; Šedo, Ondrej; Kašparovský, Tomáš; Hejátko, Jan; Lochman, Jan

    2017-03-01

    Plant plasma membrane associated proteins play significant roles in Microbe-Associated Molecular Pattern (MAMP) mediated defence responses including signal transduction, membrane transport or energetic metabolism. To elucidate the dynamics of proteins associated with plasma membrane in response to cryptogein, a well-known MAMP of defence reaction secreted by the oomycete Phytophthora cryptogea, 2D-Blue Native/SDS gel electrophoresis of plasma membrane fractions was employed. This approach revealed 21 up- or down-regulated protein spots of which 15 were successfully identified as proteins related to transport through plasma membrane, vesicle trafficking, and metabolic enzymes including cytosolic NADP-malic enzyme and glutamine synthetase. Observed changes in proteins were also confirmed on transcriptional level by qRT-PCR analysis. In addition, a significantly decreased accumulation of transcripts observed after employment of a mutant variant of cryptogein Leu41Phe, exhibiting a conspicuous defect in induction of resistance, sustains the contribution of identified proteins in cryptogein-triggered cellular responses. Our data provide further evidence for dynamic MAMP-induced changes in plasma membrane associated proteins. Copyright © 2016 Elsevier GmbH. All rights reserved.

  18. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    International Nuclear Information System (INIS)

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  19. The theory of toroidally confined plasmas

    CERN Document Server

    White, Roscoe B

    2014-01-01

    This graduate level textbook develops the theory of magnetically confined plasma, with the aim of bringing the reader to the level of current research in the field of thermonuclear fusion. It begins with the basic concepts of magnetic field description, plasma equilibria and stability, and goes on to derive the equations for guiding center particle motion in an equilibrium field. Topics include linear and nonlinear ideal and resistive modes and particle transport. It is of use to workers in the field of fusion both for its wide-ranging account of tokamak physics and as a kind of handbook or formulary. This edition has been extended in a number of ways. The material on mode-particle interactions has been reformulated and much new information added, including methodology for Monte Carlo implementation of mode destabilization. These results give explicit means of carrying out mode destabilization analysis, in particular for the dangerous fishbone mode. A new chapter on cyclotron motion in toroidal geometry has ...

  20. A systematic review and meta-analysis of plasma amyloid 1-42 and tau as biomarkers for Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Keerthanaa Balasubramanian Shanthi

    2015-08-01

    Full Text Available Objective: Amyloid 1-42 (Aβ42 and tau in cerebrospinal fluid are currently used as markers for diagnosis of Alzheimer’s disease. Conflicting reports exist regarding their plasma levels in Alzheimer’s disease patients. A meta-analysis was performed to statistically validate the use of plasma Aβ42 and tau as biomarkers for Alzheimer’s disease. Methods: Different databases were searched using the search key: (amyloid OR amyloid1-42 OR Aβ42 AND (tau OR total tau AND plasma AND (alzheimer’s OR alzheimer’s disease, and for databases not accepting boolean search, records were retrieved using the search key: plasma + amyloid + tau + alzheimer’s. A total of 1880 articles for Aβ42 and 1508 articles for tau were shortlisted. The abstracts were screened, and 69 articles reporting plasma Aβ42 levels and 6 articles reporting plasma tau were identified. After exclusion, 25 studies reporting plasma Aβ42 and 6 studies reporting total tau were analysed in Review Manager version 5.2 using weighted mean difference method, and the bias between studies was assessed using the funnel plot. Results: Plasma Aβ42 and tau did not vary significantly between Alzheimer’s disease patients and controls. The funnel plot showed that there was no bias between studies for Aβ42, while possible bias existed for tau due to availability of limited studies. Conclusion: This analysis pinpoints that plasma Aβ42 and tau could not serve as reliable markers independently for diagnosis of Alzheimer’s disease and a cohort study with age, sex and apolipoprotein E correction is warranted for their possible use as Alzheimer’s disease markers.

  1. Plasma response to electron energy filter in large volume plasma device

    International Nuclear Information System (INIS)

    Sanyasi, A. K.; Awasthi, L. M.; Mattoo, S. K.; Srivastava, P. K.; Singh, S. K.; Singh, R.; Kaw, P. K.

    2013-01-01

    An electron energy filter (EEF) is embedded in the Large Volume Plasma Device plasma for carrying out studies on excitation of plasma turbulence by a gradient in electron temperature (ETG) described in the paper of Mattoo et al. [S. K. Mattoo et al., Phys. Rev. Lett. 108, 255007 (2012)]. In this paper, we report results on the response of the plasma to the EEF. It is shown that inhomogeneity in the magnetic field of the EEF switches on several physical phenomena resulting in plasma regions with different characteristics, including a plasma region free from energetic electrons, suitable for the study of ETG turbulence. Specifically, we report that localized structures of plasma density, potential, electron temperature, and plasma turbulence are excited in the EEF plasma. It is shown that structures of electron temperature and potential are created due to energy dependence of the electron transport in the filter region. On the other hand, although structure of plasma density has origin in the particle transport but two distinct steps of the density structure emerge from dominance of collisionality in the source-EEF region and of the Bohm diffusion in the EEF-target region. It is argued and experimental evidence is provided for existence of drift like flute Rayleigh-Taylor in the EEF plasma

  2. Two new planar coil designs for a high pressure radio frequency plasma source

    Science.gov (United States)

    Munsat, T.; Hooke, W. M.; Bozeman, S. P.; Washburn, S.

    1995-04-01

    Two planar coil designs for a high pressure rf plasma source are investigated using spectroscopic techniques and circuit analysis. In an Ar plasma a truncated version of the commonly used ``spiral'' coil is found to produce improvements in peak electron density of 20% over the full version. A coil with figure-8 geometry is found to move plasma inhomogeneities off of center and produce electron densities comparable to the spiral coils. Both of these characteristics are advantageous in industrial applications. Coil design characteristics for favorable power coupling are also determined, including the necessity of closed hydrodynamic plasma loops and the drawback of closely situated antiparallel coil currents.

  3. Monoexponential analysis of plasma disappearance of 99mTc-DTPA and 131I-iodohippurate: A reliable method for measuring changes of renal function

    International Nuclear Information System (INIS)

    Clifton, G.G.; Anderson, C.; McMahon, G.; Vargas, R.; Wallin, J.D.

    1989-01-01

    Glomerular filtration rate and effective renal plasma flow were measured in 170 subjects using monoexponential analysis of plasma disappearance curves for 99m Tc-DTPA and 131 I-iodohippurate after single injection. In the current study population, glomerular filtration rate and effective renal plasma flow decreased with increasing age, were less in females than in males, and were less in hypertensives than in normotensives. Differences in glomerular filtration rate according to age and sex in the current study were similar to those reported using traditional creatinine clearance methodology. Monoexponential treatment of plasma isotope disappearance gave reproducible values for both glomerular filtration rate and effective renal plasma flow when measured either during the day or on a daily basis. Intraindividual coefficient of variation was less than 10% for both 99m Tc-DTPA and 131 I-iodohippurate clearances derived from monoexponential analysis. These results demonstrate that monoexponential analysis of plasma disappearance curves for 99m Tc-DTPA and 131 I-iodohippurate after a single injection is a useful method for evaluating changes in renal hemodynamics either during chronic drug therapy or acutely after single dose administration

  4. Electron heating via self-excited plasma series resonance in geometrically symmetric multi-frequency capacitive plasmas

    International Nuclear Information System (INIS)

    Schüngel, E; Brandt, S; Schulze, J; Donkó, Z; Korolov, I; Derzsi, A

    2015-01-01

    The self-excitation of plasma series resonance (PSR) oscillations plays an important role in the electron heating dynamics in capacitively coupled radio-frequency (CCRF) plasmas. In a combined approach of PIC/MCC simulations and a theoretical model based on an equivalent circuit, we investigate the self-excitation of PSR oscillations and their effect on the electron heating in geometrically symmetric CCRF plasmas driven by multiple consecutive harmonics. The discharge symmetry is controlled via the electrical asymmetry effect (EAE), i.e. by varying the total number of harmonics and tuning the phase shifts between them. It is demonstrated that PSR oscillations will be self-excited under both symmetric and asymmetric conditions, if (i) the charge–voltage relation of the plasma sheaths deviates from a simple quadratic behavior and (ii) the inductance of the plasma bulk exhibits a temporal modulation. These two effects have been neglected up to now, but we show that they must be included in the model in order to properly describe the nonlinear series resonance circuit and reproduce the self-excitation of PSR oscillations, which are observed in the electron current density resulting from simulations of geometrically symmetric CCRF plasmas. Furthermore, the effect of PSR self-excitation on the discharge current and the plasma properties, such as the potential profile, is illustrated by applying Fourier analysis. High-frequency oscillations in the entire spectrum between the applied frequencies and the local electron plasma frequency are observed. As a consequence, the electron heating is strongly enhanced by the presence of PSR oscillations. A complex electron heating dynamics is found during the expansion phase of the sheath, which is fully collapsed, when the PSR is initially self-excited. The nonlinear electron resonance heating (NERH) associated with the PSR oscillations causes a spatial asymmetry in the electron heating. By discussing the resulting ionization

  5. Antimatter plasmas and antihydrogen

    International Nuclear Information System (INIS)

    Greaves, R.G.; Surko, C.M.

    1997-01-01

    Recent successes in confining antimatter in the form of positron and antiproton plasmas have created new scientific and technological opportunities. Plasma techniques have been the cornerstone of experimental work in this area, and this is likely to be true for the foreseeable future. Work by a number of groups on trapping antimatter plasmas is summarized, and an overview of the promises and challenges in this field is presented. Topics relating to positron plasmas include the use of positrons to study the unique properties of electron endash positron plasmas, the interaction between positrons and ordinary matter, and the laboratory modeling of positron-annihilation processes in interstellar media. The availability of cold, trapped antiprotons and positrons makes possible the production of neutral antimatter in the form of antihydrogen. This is expected to enable precise comparisons of the properties of matter and antimatter, including tests of fundamental symmetries and the measurement of the interaction of antimatter with gravity. copyright 1997 American Institute of Physics

  6. A contoured gap coaxial plasma gun with injected plasma armature.

    Science.gov (United States)

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  7. A contoured gap coaxial plasma gun with injected plasma armature

    International Nuclear Information System (INIS)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard II; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond

    2009-01-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 μg of plasma with density above 10 17 cm -3 to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 μg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  8. Modeling of Plasma-Induced Ignition and Combustion

    National Research Council Canada - National Science Library

    Boyd, Iain D; Keidar, Michael

    2008-01-01

    .... Phenomena that must be considered in an electrothermal chemical gun model include the initial capillary plasma properties, the plasma-air interaction, plasma sheath effects, and the plasma-propellant interaction itself...

  9. Influence of consumption of probiotics on the plasma lipid profile: a meta-analysis of randomised controlled trials.

    Science.gov (United States)

    Guo, Z; Liu, X M; Zhang, Q X; Shen, Z; Tian, F W; Zhang, H; Sun, Z H; Zhang, H P; Chen, W

    2011-11-01

    Human clinical studies have yielded mixed results on the effects of consumption of probiotics on the plasma lipid profile. We conducted a meta-analysis of randomised controlled trials that evaluated the effects of probiotics consumption on blood lipids. A systematic literature search of Embase, Web of Science, PubMed and Cochrane Controlled Trials Registry was conducted for studies that investigated the efficacy of probiotics on the plasma lipid profile of subjects. With the help of Review Manager 4.2, data from 13 trials, which included 485 participants with high, borderline high and normal cholesterol levels, were examined. The pooled mean net change in total cholesterol for those treated with probiotics compared to controls was -6.40 mg dl(-1) (95% confidence interval (CI), -9.93 to -2.87), mean net change in low-density lipoprotein (LDL) cholesterol was -4.90 mg dl(-1) (95% CI, -7.91 to -1.90), mean net change in high-density lipoprotein (HDL) cholesterol was -0.11 mg dl(-1) (95% CI, -1.90-1.69) and mean net change in triglycerides was -3.95 mg dl(-1) (95% CI, -10.32-2.42). These results indicate that a diet rich in probiotics decreases total cholesterol and LDL cholesterol concentration in plasma for participants with high, borderline high and normal cholesterol levels. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Radiofrequency power in plasmas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This document includes the various communications that were presented at the 11th topical conference on radio frequency power in plasmas which took place in Palm Springs in May 1995. It includes current diffusion studies to assess the non-inductive current deposition profiles, experiments for plasma to reach quickly an equilibrium state, and modelling of electrons in plasma. Some comparison studies also reveal the efficiency of the Quasi-Optical Grill antenna for reactor applications. Finally, a scenario for efficient mode conversion heating in the ion cyclotron range of frequency is presented. Separate abstracts were prepared for the 6 papers in this volume. (TEC).

  11. A study of quasi-mode parametric excitations in lower-hybrid heating of tokamak plasmas

    International Nuclear Information System (INIS)

    Villalon, E.; Bers, A.

    1980-01-01

    A detailed linear and non-linear analysis of quasi-mode parametric excitations relevant to experiments in supplementary heating of tokamak plasmas is presented. The linear analysis includes the full ion-cyclotron harmonic quasi-mode spectrum. The non-linear analysis, considering depletion of the pump electric field, is applied to the recent Alcator A heating experiment. Because of the very different characteristics of a tokamak plasma near the wall (in the shadow of the limiter) and inside, the quasi-mode excitations are studied independently for the plasma edge and the main bulk of the plasma, and for two typical regimes in overall density, the low (peak in density, n 0 =1.5x10 14 cm -3 ) and high (n 0 =5x10 14 cm -3 ) density regimes. At the edge of the plasma and for the low-density regime, it is found that higher nsub(z)(nsub(z)=cksub(z)/ω) than those predicted by the linear theory are strongly excited. Inside the plasma, the excitation of higher wave numbers is also significant. These results indicate that a large amount of the RF-power may not penetrate to the plasma centre, but will rather be either Landau-damped on the electrons or mode-converted into thermal modes, close to the plasma edge. Moreover, for sufficiently high peaks in density, it is found that all the RF-power is mode-converted before reaching the plasma centre. Inside the plasma, the power density of the excited sideband fields is shown to be always very small in comparison with their excitation at the plasma edge. (author)

  12. Studies of the ablated plasma from experimental plasma gun disruption simulations

    International Nuclear Information System (INIS)

    Rockett, P.D.; Hunter, J.A.; Bradley, J.T.

    1994-01-01

    Extensive simulations of Tokamak disruptions have provided a picture of material erosion that is limited by the transfer of energy from the incident plasma to the armor solid surface through a dense vapor shield. Radiation spectra were recorded in the VUV and in the visible at the Efremov Laboratories on VIKA using graphite targets. The VUV data were recorded with a Sandia Labs transmission grating spectrograph, covering 1--40 nm. Plasma parameters were evaluated with incident plasma energy densities varying from 1--10 kJ/cm 2 . A second transmission grating spectrograph was taken to 2MK-200 at TRINITI to study the plasma-material interface in magnetic cusp plasma. Target materials included POCO graphite, ATJ graphite, boron nitride, and plasma-sprayed tungsten. Detailed spectra were recorded with a spatial resolution of ∼1 mm resolution. Time-resolved data with 40--200 ns resolution was also recorded. The data from both plasma gun facilities demonstrated that the hottest plasma region was sitting several millimeters above the armor tile surface

  13. High Temperature Plasmas Theory and Mathematical Tools for Laser and Fusion Plasmas

    CERN Document Server

    Spatschek, Karl-Heinz

    2012-01-01

    Filling the gap for a treatment of the subject as an advanced course in theoretical physics with a huge potential for future applications, this monograph discusses aspects of these applications and provides theoretical methods and tools for their investigation. Throughout this coherent and up-to-date work the main emphasis is on classical plasmas at high-temperatures, drawing on the experienced author's specialist background. As such, it covers the key areas of magnetic fusion plasma, laser-plasma-interaction and astrophysical plasmas, while also including nonlinear waves and phenomena.

  14. UPLC-ESI-QTOF/MS and multivariate data analysis for blood plasma and serum metabolomics: effect of experimental artefacts and anticoagulant

    DEFF Research Database (Denmark)

    Barri, Thaer; Dragsted, Lars Ove

    2013-01-01

    agents, e.g. heparin, EDTA and citrate. In the present study, we looked into metabolite and other differences in matched serum and plasma samples and different plasma preparations by using untargeted UPLC-ESI-QTOF/MS profiling and multivariate data analysis (PCA and OPLS-DA). Metabolite differences......Clotting and anticoagulation of blood samples may give rise to different metabolic profiles of serum and plasma samples, respectively. The anticoagulant used for blood plasma preparation may affect the resulting metabolic profile due to different mechanisms involved in anticoagulation by various...... between serum and plasma samples were mainly related to small peptides reflecting presence or absence of coagulation. Only subtle metabolite differences between the different plasma preparations were noticed, which were primarily related to ion suppression or enhancement caused by citrate and EDTA...

  15. The isentropic relation in plasmas

    International Nuclear Information System (INIS)

    Burm, K T A L

    2004-01-01

    The isentropic relation from gas dynamics relates pressure, density and temperature. The use of this relation may ease the hydrodynamic modelling effort. Characteristic for the isentropic relation is the constant isentropic exponent. The isentropic exponent is also in the case of plasmas a constant as long as the ionization degree is between 5 and 80%. This constant is lower due to the extra degree of freedom which comes with ionization in plasmas. The occurrence of ionization means that plasmas are never isentropic. The isentropic relation itself is therefore adapted here to include plasmas within its concept. From the plasma isentropic relation a further extension is to include viscosity and heating. It is found that all extra non-isentropic inclusions further lower the (quasi-) isentropic exponent in the adapted isentropic relation

  16. Molecular-dynamics analysis of mobile helium cluster reactions near surfaces of plasma-exposed tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Lin; Maroudas, Dimitrios, E-mail: maroudas@ecs.umass.edu [Department of Chemical Engineering, University of Massachusetts, Amherst, Massachusetts 01003-9303 (United States); Hammond, Karl D. [Department of Chemical Engineering, University of Missouri, Columbia, Missouri 65211 (United States); Wirth, Brian D. [Department of Nuclear Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States)

    2015-10-28

    We report the results of a systematic atomic-scale analysis of the reactions of small mobile helium clusters (He{sub n}, 4 ≤ n ≤ 7) near low-Miller-index tungsten (W) surfaces, aiming at a fundamental understanding of the near-surface dynamics of helium-carrying species in plasma-exposed tungsten. These small mobile helium clusters are attracted to the surface and migrate to the surface by Fickian diffusion and drift due to the thermodynamic driving force for surface segregation. As the clusters migrate toward the surface, trap mutation (TM) and cluster dissociation reactions are activated at rates higher than in the bulk. TM produces W adatoms and immobile complexes of helium clusters surrounding W vacancies located within the lattice planes at a short distance from the surface. These reactions are identified and characterized in detail based on the analysis of a large number of molecular-dynamics trajectories for each such mobile cluster near W(100), W(110), and W(111) surfaces. TM is found to be the dominant cluster reaction for all cluster and surface combinations, except for the He{sub 4} and He{sub 5} clusters near W(100) where cluster partial dissociation following TM dominates. We find that there exists a critical cluster size, n = 4 near W(100) and W(111) and n = 5 near W(110), beyond which the formation of multiple W adatoms and vacancies in the TM reactions is observed. The identified cluster reactions are responsible for important structural, morphological, and compositional features in the plasma-exposed tungsten, including surface adatom populations, near-surface immobile helium-vacancy complexes, and retained helium content, which are expected to influence the amount of hydrogen re-cycling and tritium retention in fusion tokamaks.

  17. Structure function analysis of long-range correlations in plasma turbulence

    International Nuclear Information System (INIS)

    Yu, C.X.; Gilmore, M.; Peebles, W.A.; Rhodes, T.L.

    2003-01-01

    Long-range correlations (temporal and spatial) have been predicted in a number of different turbulence models, both analytical and numerical. These long-range correlations are thought to significantly affect cross-field turbulent transport in magnetically confined plasmas. The Hurst exponent, H - one of a number of methods to identify the existence of long-range correlations in experimental data - can be used to quantify self-similarity scalings and correlations in the mesoscale temporal range. The Hurst exponent can be calculated by several different algorithms, each of which has particular advantages and disadvantages. One method for calculating H is via structure functions (SFs). The SF method is a robust technique for determining H with several inherent advantages that has not yet been widely used in plasma turbulence research. In this article, the SF method and its advantages are discussed in detail, using both simulated and measured fluctuation data from the DIII-D tokamak [J. L. Luxon and L. G. Davis, Fusion Technol. 8, 441 (1985)]. In addition, it is shown that SFs used in conjunction with rescaled range analysis (another method for calculating H) can be used to mitigate the effects of coherent modes in some cases

  18. Altered expression of circulating microRNA in plasma of patients with primary osteoarthritis and in silico analysis of their pathways.

    Directory of Open Access Journals (Sweden)

    Verónica M Borgonio Cuadra

    Full Text Available OBJECTIVE: To analyze a set of circulating microRNA (miRNA in plasma from patients with primary Osteoarthritis (OA and describe the biological significance of altered miRNA in OA based on an in silico analysis of their target genes. METHODS: miRNA expression was analyzed using TaqMan Low Density Arrays and independent assays. The search for potential messenger RNA (mRNA targets of the differentially expressed miRNA was performed by means of the miRWalk and miRecords database; we conducted the biological relevance of the predicted miRNA targets by pathway analysis with the Reactome and DAVID databases. RESULTS: We measured the expression of 380 miRNA in OA; 12 miRNA were overexpressed under the OA condition (p value, ≤0.05; fold change, >2. These results were validated by the detection of some selected miRNA by quantitative PCR (qPCR. In silico analysis showed that target messenger RNA (mRNA were potentially regulated by these miRNA, including genes such as SMAD1, IL-1B, COL3A, VEGFA, and FGFR1, important in chondrocyte maintenance and differentiation. Some metabolic pathways affected by the miRNA: mRNA ratio are signaling Bone morphogenetic proteins (BMP, Platelet-derived growth factor (PDGF, and Nerve growth factor (NGF, these latter two involved in the process of pain. CONCLUSIONS: We identified 12 miRNA in the plasma of patients with primary OA. Specific miRNA that are altered in the disease could be released into plasma, either due to cartilage damage or to an inherent cellular mechanism. Several miRNA could regulate genes and pathways related with development of the disease; eight of these circulating miRNA are described, to our knowledge, for first time in OA.

  19. Multi-Accuracy-Level Burning Plasma Simulations

    International Nuclear Information System (INIS)

    Artaud, J. F.; Basiuk, V.; Garcia, J.; Giruzzi, G.; Huynh, P.; Huysmans, G.; Imbeaux, F.; Johner, J.; Scheider, M.

    2007-01-01

    The design of a reactor grade tokamak is based on a hierarchy of tools. We present here three codes that are presently used for the simulations of burning plasmas. At the first level there is a 0-dimensional code that allows to choose a reasonable range of global parameters; in our case the HELIOS code was used for this task. For the second level we have developed a mixed 0-D / 1-D code called METIS that allows to study the main properties of a burning plasma, including profiles and all heat and current sources, but always under the constraint of energy and other empirical scaling laws. METIS is a fast code that permits to perform a large number of runs (a run takes about one minute) and design the main features of a scenario, or validate the results of the 0-D code on a full time evolution. At the top level, we used the full 1D1/2 suite of codes CRONOS that gives access to a detailed study of the plasma profiles evolution. CRONOS can use a variety of modules for source terms and transport coefficients computation with different level of complexity and accuracy: from simple estimators to highly sophisticated physics calculations. Thus it is possible to vary the accuracy of burning plasma simulations, as a trade-off with computation time. A wide range of scenario studies can thus be made with CRONOS and then validated with post-processing tools like MHD stability analysis. We will present in this paper results of this multi-level analysis applied to the ITER hybrid scenario. This specific example will illustrate the importance of having several tools for the study of burning plasma scenarios, especially in a domain that present devices cannot access experimentally. (Author)

  20. Experimental studies of collisional plasma shocks and plasma interpenetration via merging supersonic plasma jets

    Science.gov (United States)

    Hsu, S. C.; Moser, A. L.; Merritt, E. C.; Adams, C. S.

    2015-11-01

    Over the past 4 years on the Plasma Liner Experiment (PLX) at LANL, we have studied obliquely and head-on-merging supersonic plasma jets of an argon/impurity or hydrogen/impurity mixture. The jets are formed/launched by pulsed-power-driven railguns. In successive experimental campaigns, we characterized the (a) evolution of plasma parameters of a single plasma jet as it propagated up to ~ 1 m away from the railgun nozzle, (b) density profiles and 2D morphology of the stagnation layer and oblique shocks that formed between obliquely merging jets, and (c) collisionless interpenetration transitioning to collisional stagnation between head-on-merging jets. Key plasma diagnostics included a fast-framing CCD camera, an 8-chord visible interferometer, a survey spectrometer, and a photodiode array. This talk summarizes the primary results mentioned above, and highlights analyses of inferred post-shock temperatures based on observations of density gradients that we attribute to shock-layer thickness. We also briefly describe more recent PLX experiments on Rayleigh-Taylor-instability evolution with magnetic and viscous effects, and potential future collisionless shock experiments enabled by low-impurity, higher-velocity plasma jets formed by contoured-gap coaxial guns. Supported by DOE Fusion Energy Sciences and LANL LDRD.

  1. Plasma engineering analysis of a small torsatron reactor

    International Nuclear Information System (INIS)

    Lacatski, J.T.; Houlberg, W.A.; Uckan, N.A.

    1985-10-01

    This study examines the plasma physics and reactor engineering feasibility of a small, medium aspect ratio, high-beta, l = 2, D-T torsatron power reactor, based on the magnetic configuration of the Advanced Toroidal Facility, Oak Ridge National Laboratory. Plasma analyses are performed to assess whether confinement in a small, average radius plasma is sufficient to yield an ignited or high-Q driven device. Much of the physics assessment focuses on an evaluation of the radial electric field created by the nonambipolar particle flux. Detailed transport simulations are done with both fixed and self-consistent evolution of the radial electric field. Basic reactor engineering considerations taken into account are neutron wall loading, maximum magnetic field at the helical coils, coil shield thickness, and tritium breeding blanket-shield thickness

  2. A Phospholipidomic Analysis of All Defined Human Plasma Lipoproteins

    NARCIS (Netherlands)

    Dashti, Monireh; Kulik, Willem; Hoek, Frans; Veerman, Enno C.; Peppelenbosch, Maikel P.; Rezaee, Farhad

    2011-01-01

    Since plasma lipoproteins contain both protein and phospholipid components, either may be involved in processes such as atherosclerosis. In this study the identification of plasma lipoprotein-associated phospholipids, which is essential for understanding these processes at the molecular level, are

  3. A phospholipidomic analysis of all defined human plasma lipoproteins

    NARCIS (Netherlands)

    Dashti, Monireh; Kulik, Willem; Hoek, Frans; Veerman, Enno C.; Peppelenbosch, Maikel P.; Rezaee, Farhad

    2011-01-01

    Since plasma lipoproteins contain both protein and phospholipid components, either may be involved in processes such as atherosclerosis. In this study the identification of plasma lipoprotein-associated phospholipids, which is essential for understanding these processes at the molecular level, are

  4. Collisional-radiative model including recombination processes for W27+ ion★

    Science.gov (United States)

    Murakami, Izumi; Sasaki, Akira; Kato, Daiji; Koike, Fumihiro

    2017-10-01

    We have constructed a collisional-radiative (CR) model for W27+ ions including 226 configurations with n ≤ 9 and ł ≤ 5 for spectroscopic diagnostics. We newly include recombination processes in the model and this is the first result of extreme ultraviolet spectrum calculated for recombining plasma component. Calculated spectra in 40-70 Å range in ionizing and recombining plasma components show similar 3 strong lines and 1 line weak in recombining plasma component at 45-50 Å and many weak lines at 50-65 Å for both components. Recombination processes do not contribute much to the spectrum at around 60 Å for W27+ ion. Dielectronic satellite lines are also minor contribution to the spectrum of recombining plasma component. Dielectronic recombination (DR) rate coefficient from W28+ to W27+ ions is also calculated with the same atomic data in the CR model. We found that larger set of energy levels including many autoionizing states gave larger DR rate coefficients but our rate agree within factor 6 with other works at electron temperature around 1 keV in which W27+ and W28+ ions are usually observed in plasmas. Contribution to the Topical Issue "Atomic and Molecular Data and their Applications", edited by Gordon W.F. Drake, Jung-Sik Yoon, Daiji Kato, and Grzegorz Karwasz.

  5. Plasma control using neural network and optical emission spectroscopy

    International Nuclear Information System (INIS)

    Kim, Byungwhan; Bae, Jung Ki; Hong, Wan-Shick

    2005-01-01

    Due to high sensitivity to process parameters, plasma processes should be tightly controlled. For plasma control, a predictive model was constructed using a neural network and optical emission spectroscopy (OES). Principal component analysis (PCA) was used to reduce OES dimensionality. This approach was applied to an oxide plasma etching conducted in a CHF 3 /CF 4 magnetically enhanced reactive ion plasma. The etch process was systematically characterized by means of a statistical experimental design. Three etch outputs (etch rate, profile angle, and etch rate nonuniformity) were modeled using three different approaches, including conventional, OES, and PCA-OES models. For all etch outputs, OES models demonstrated improved predictions over the conventional or PCA-OES models. Compared to conventional models, OES models yielded an improvement of more than 25% in modeling profile angle and etch rate nonuniformtiy. More than 40% improvement over PCA-OES model was achieved in modeling etch rate and profile angle. These results demonstrate that nonreduced in situ data are more beneficial than reduced one in constructing plasma control model

  6. Analysis of heat transfer and erosion effects on ITER divertor plasma facing components induced by slow high-power transients

    International Nuclear Information System (INIS)

    Federici, G.; Raffray, A.R.; Chiocchio, S.; Esser, B.; Dietz, J.; Igitkhanov, Y.; Janeschitz, G.

    1995-01-01

    This paper presents the results of an analysis carried out to investigate the thermal response of ITER divertor plasma facing components (PFC's) clad with Be, W, and CFC, to high-recycling, high-power thermal transients (i.e. 10--30 MW/m 2 ) which are anticipated to last up to a few seconds. The armour erosion and surface melting are estimated for the different plasma facing materials (PFM's) together with the maximum heat flux to the coolant, and armour/heat-sink interface temperature. The analysis assumes that intense target evaporation will lead to high radiative power losses in the plasma in front of the target which self-protects the target. The cases analyzed clarify the influence of several key parameters such as the plasma heat flux to the target, the loss of the melt layer, the duration of the event, the thickness of the armour, and comparison is made with cases without vapor shielding. Finally, some implications for the performance and lifetime of divertor PFC's clad with different PFM's are discussed

  7. Understanding Turbulence in Compressing Plasmas and Its Exploitation or Prevention

    Science.gov (United States)

    Davidovits, Seth

    Unprecedented densities and temperatures are now achieved in compressions of plasma, by lasers and by pulsed power, in major experimental facilities. These compressions, carried out at the largest scale at the National Ignition Facility and at the Z Pulsed Power Facility, have important applications, including fusion, X-ray production, and materials research. Several experimental and simulation results suggest that the plasma in some of these compressions is turbulent. In fact, measurements suggest that in certain laboratory plasma compressions the turbulent energy is a dominant energy component. Similarly, turbulence is dominant in some compressing astrophysical plasmas, such as in molecular clouds. Turbulence need not be dominant to be important; even small quantities could greatly influence experiments that are sensitive to mixing of non-fuel into fuel, such as compressions seeking fusion ignition. Despite its important role in major settings, bulk plasma turbulence under compression is insufficiently understood to answer or even to pose some of the most fundamental questions about it. This thesis both identifies and answers key questions in compressing turbulent motion, while providing a description of the behavior of three-dimensional, isotropic, compressions of homogeneous turbulence with a plasma viscosity. This description includes a simple, but successful, new model for the turbulent energy of plasma undergoing compression. The unique features of compressing turbulence with a plasma viscosity are shown, including the sensitivity of the turbulence to plasma ionization, and a "sudden viscous dissipation'' effect which rapidly converts plasma turbulent energy into thermal energy. This thesis then examines turbulence in both laboratory compression experiments and molecular clouds. It importantly shows: the possibility of exploiting turbulence to make fusion or X-ray production more efficient; conditions under which hot-spot turbulence can be prevented; and a

  8. Plasma processing for VLSI

    CERN Document Server

    Einspruch, Norman G

    1984-01-01

    VLSI Electronics: Microstructure Science, Volume 8: Plasma Processing for VLSI (Very Large Scale Integration) discusses the utilization of plasmas for general semiconductor processing. It also includes expositions on advanced deposition of materials for metallization, lithographic methods that use plasmas as exposure sources and for multiple resist patterning, and device structures made possible by anisotropic etching.This volume is divided into four sections. It begins with the history of plasma processing, a discussion of some of the early developments and trends for VLSI. The second section

  9. Plasma heating - a comparative overview for future applications

    International Nuclear Information System (INIS)

    Wilhelm, R.

    1989-01-01

    Successful plasma heating is essential in present fusion experiments, for the demonstration of D-T burn in future devices and finally for the fusion reactor itself. This paper discusses the common heating system with respect to their present performance and their applicability to future fusion devices. The comparative discussion is oriented to the various functions of heating, which are: Plasma heating to fusion-relevant parameters and to ignition in future machines, non-inductive, steady-state current drive, plasma profile control, neutral gas breakdown and plasma build-up. In view of these different functions, the potential of neutral beam injection (NBI) and the various schemes of wave heating (ECRH, LH, ICRH and Alfven wave heating) is analyzed in more detail. The analysis includes assessments of the present physical and technical state of these heating methods, and makes suggestions for future developments and about outstanding problems. Specific attention is given to the still critical problem of efficient current drive, especially with respect to further extrapolation towards an economically operating tokamak reactor. Remarks on issues such as reliability, maintenance and economy conclude this comparative overview on plasma heating systems. (orig.)

  10. Correlation anlaysis of plasma fluctuation signals

    International Nuclear Information System (INIS)

    Wan Baonian; Wang Zhaoshen

    1987-01-01

    The application of correlation analysis to identify waves and instabilities in plasma is presented. First, the principle of correlation analysis and its application to diagnose plasma fluctuation signals are given. Then, the data acqusition system, application program and calibration method are described. Finally, experimental results from a mirror device are given

  11. Particle beams and plasmas

    International Nuclear Information System (INIS)

    Hofmann, A.; Messerschmid, E.; Lawson, J.D.

    1976-01-01

    These lectures present a survey of some of the concepts of plasma physics and look at some situations familiar to particle-accelerator physicists from the point of view of a plasma physicist, with the intention of helping to link together the two fields. At the outset, basic plasma concepts are presented, including definitions of a plasma, characteristic parameters, magnetic pressure and confinement. This is followed by a brief discussion on plasma kinetic theory, non-equilibrium plasma, and the temperature of moving plasmas. Examples deal with beams in the CERN Intersecting Storage Rings as well as with non-steady beams in cyclic accelerators and microwave tubes. In the final chapters, time-varying systems are considered: waves in free space and the effect of cylinder bounds, wave motion in cold stationary plasmas, and waves in plasmas with well-defined streams. The treatment throughout is informal, with emphasis on the essential physical properties of continuous beams in accelerators and storage rings in relation to the corresponding problems in plasma physics and microwave tubes. (Author)

  12. Boundary Plasma Turbulence Simulations for Tokamaks

    International Nuclear Information System (INIS)

    Xu, X.; Umansky, M.; Dudson, B.; Snyder, P.

    2008-05-01

    The boundary plasma turbulence code BOUT models tokamak boundary-plasma turbulence in a realistic divertor geometry using modified Braginskii equations for plasma vorticity, density (ni), electron and ion temperature (T e ; T i ) and parallel momenta. The BOUT code solves for the plasma fluid equations in a three dimensional (3D) toroidal segment (or a toroidal wedge), including the region somewhat inside the separatrix and extending into the scrape-off layer; the private flux region is also included. In this paper, a description is given of the sophisticated physical models, innovative numerical algorithms, and modern software design used to simulate edge-plasmas in magnetic fusion energy devices. The BOUT code's unique capabilities and functionality are exemplified via simulations of the impact of plasma density on tokamak edge turbulence and blob dynamics

  13. Relative Abundance of Proteins in Blood Plasma Samples from Patients with Chronic Cerebral Ischemia.

    Science.gov (United States)

    Kaysheva, Anna L; Kopylov, Artur T; Ponomarenko, Elena A; Kiseleva, Olga I; Teryaeva, Nadezhda B; Potapov, Alexander A; Izotov, Alexander А; Morozov, Sergei G; Kudryavtseva, Valeria Yu; Archakov, Alexander I

    2018-03-01

    A comparative protein profile analysis of 17 blood plasma samples from patients with ischemia and 20 samples from healthy volunteers was carried out using ultra-high resolution mass spectrometry. The analysis of measurements was performed using the proteomics search engine OMSSA. Normalized spectrum abundance factor (NSAF) in the biological samples was assessed using SearchGUI. The findings of mass spectrometry analysis of the protein composition of blood plasma samples demonstrate that the depleted samples are quite similar in protein composition and relative abundance of proteins. By comparing them with the control samples, we have found a small group of 44 proteins characteristic of the blood plasma samples from patients with chronic cerebral ischemia. These proteins contribute to the processes of homeostasis maintenance, including innate immune response unfolding, the response of a body to stress, and contribution to the blood clotting cascade.

  14. Correlation between the plasma characteristics and the surface chemistry of plasma-treated polymers through partial least-squares analysis.

    Science.gov (United States)

    Mavadat, Maryam; Ghasemzadeh-Barvarz, Massoud; Turgeon, Stéphane; Duchesne, Carl; Laroche, Gaétan

    2013-12-23

    We investigated the effect of various plasma parameters (relative density of atomic N and H, plasma temperature, and vibrational temperature) and process conditions (pressure and H2/(N2 + H2) ratio) on the chemical composition of modified poly(tetrafluoroethylene) (PTFE). The plasma parameters were measured by means of near-infrared (NIR) and UV-visible emission spectroscopy with and without actinometry. The process conditions of the N2-H2 microwave discharges were set at various pressures ranging from 100 to 2000 mTorr and H2/(N2+H2) gas mixture ratios between 0 and 0.4. The surface chemical composition of the modified polymers was determined by X-ray photoelectron spectroscopy (XPS). A mathematical model was constructed using the partial least-squares regression algorithm to correlate the plasma information (process condition and plasma parameters as determined by emission spectroscopy) with the modified surface characteristics. To construct the model, a set of data input variables containing process conditions and plasma parameters were generated, as well as a response matrix containing the surface composition of the polymer. This model was used to predict the composition of PTFE surfaces subjected to N2-H2 plasma treatment. Contrary to what is generally accepted in the literature, the present data demonstrate that hydrogen is not directly involved in the defluorination of the surface but rather produces atomic nitrogen and/or NH radicals that are shown to be at the origin of fluorine atom removal from the polymer surface. The results show that process conditions alone do not suffice in predicting the surface chemical composition and that the plasma characteristics, which cannot be easily correlated with these conditions, should be considered. Process optimization and control would benefit from plasma diagnostics, particularly infrared emission spectroscopy.

  15. Metal droplet erosion and shielding plasma layer under plasma flows typical of transient processes in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Martynenko, Yu. V., E-mail: Martynenko-YV@nrcki.ru [National Research Nuclear University “MEPhI” (Russian Federation)

    2017-03-15

    It is shown that the shielding plasma layer and metal droplet erosion in tokamaks are closely interrelated, because shielding plasma forms from the evaporated metal droplets, while droplet erosion is caused by the shielding plasma flow over the melted metal surface. Analysis of experimental data and theoretical models of these processes is presented.

  16. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  17. Characterization of pulsed atmospheric-pressure plasma streams (PAPS) generated by a plasma gun

    Science.gov (United States)

    Robert, E.; Sarron, V.; Riès, D.; Dozias, S.; Vandamme, M.; Pouvesle, J.-M.

    2012-06-01

    An experimental study of atmospheric-pressure rare gas plasma propagation in a high-aspect-ratio capillary is reported. The plasma is generated with a plasma gun device based on a dielectric barrier discharge (DBD) reactor powered by either nanosecond or microsecond rise-time high-voltage pulses at single-shot to multi-kHz frequencies. The influence of the voltage waveform, pulse polarity, pulse repetition rate and capillary material have been studied using nanosecond intensified charge-coupled device imaging and plasma-front velocity measurements. The evolution of the plasma appearance during its propagation and the study of the role of the different experimental parameters lead us to suggest a new denomination of pulsed atmospheric-pressure plasma streams to describe all the plasma features, including the previously so-called plasma bullet. The unique properties of such non-thermal plasma launching in capillaries, far from the primary DBD plasma, are associated with a fast ionization wave travelling with velocity in the 107-108 cm s-1 range. Voltage pulse tailoring is shown to allow for a significant improvement of such plasma delivery. Thus, the plasma gun device affords unique opportunities in biomedical endoscopic applications.

  18. Characterization of pulsed atmospheric-pressure plasma streams (PAPS) generated by a plasma gun

    International Nuclear Information System (INIS)

    Robert, E; Sarron, V; Riès, D; Dozias, S; Vandamme, M; Pouvesle, J-M

    2012-01-01

    An experimental study of atmospheric-pressure rare gas plasma propagation in a high-aspect-ratio capillary is reported. The plasma is generated with a plasma gun device based on a dielectric barrier discharge (DBD) reactor powered by either nanosecond or microsecond rise-time high-voltage pulses at single-shot to multi-kHz frequencies. The influence of the voltage waveform, pulse polarity, pulse repetition rate and capillary material have been studied using nanosecond intensified charge-coupled device imaging and plasma-front velocity measurements. The evolution of the plasma appearance during its propagation and the study of the role of the different experimental parameters lead us to suggest a new denomination of pulsed atmospheric-pressure plasma streams to describe all the plasma features, including the previously so-called plasma bullet. The unique properties of such non-thermal plasma launching in capillaries, far from the primary DBD plasma, are associated with a fast ionization wave travelling with velocity in the 10 7 –10 8 cm s −1 range. Voltage pulse tailoring is shown to allow for a significant improvement of such plasma delivery. Thus, the plasma gun device affords unique opportunities in biomedical endoscopic applications. (paper)

  19. Proceedings of the Japan-US workshop on plasma polarization spectroscopy and the fourth international symposium on plasma polarization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Takashi; Beiersdorfer, Peter [eds.

    2004-07-01

    The international meeting on Plasma Polarization Spectroscopy (PPS) was held at Kyoto University during February 4-6, 2004. This Proceedings book includes the summaries of the talks given in that meeting. Starting with the Overview talk by Csanak, the subjects cover: x-ray polarization experiments on z-pinches (plasma foci), and an x-pinch, a laser-produced plasma in a gas atmosphere, an interpretation of the polarized 1<- 0 x-ray laser line, polarization observation from various laser-produced plasmas including a recombining phase plasma, a report on the on-going project of a laser facility, several polarization observations on magnetically confined plasmas including the Large Helical Device and an ECR plasma, a new laser-induced fluorescence diagnostic method. On atomic physics side given are: various polarization measurements on EBIT, precision spectroscopy on the TEXTOR, user-friendly atomic codes. Instrumentation is also a subject of this book. The 18 of the presented papers are indexed individually. (J.P.N.)

  20. Analytic analysis on asymmetrical micro arcing in high plasma potential RF plasma systems

    International Nuclear Information System (INIS)

    Yin, Y; McKenzie, D R; Bilek, M M M

    2006-01-01

    We report experimental and analytical results on asymmetrical micro arcing in a RF (radio frequency) plasma. Micro arcing, resulting from high plasma potential, in RF plasma was found to occur only on the grounded electrode for a variety of electrode and surface configurations. The analytic derivation was based on a simple RF time-dependent Child-Langmuir sheath model and electric current continuity. We found that the minimum potential difference in one RF period across the grounded electrode sheath depends on the area ratio of the grounded electrode to the powered electrode. As the area ratio increases, the minimum potential difference across a sheath increases for the grounded electrode but not for the RF powered electrode. We showed that discharge time in micro arcing is more than 100 RF periods; thus the presence of a continuous high electric field in one RF cycle results in micro arcing on the grounded electrode. However, the minimum potential difference in one RF period across the powered electrode sheath is always small so that it prevents micro arcing occurring even though the average sheath voltage can be large. This simple analytic model is consistent with particle-in-cell simulation results

  1. A contoured gap coaxial plasma gun with injected plasma armature

    Energy Technology Data Exchange (ETDEWEB)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard II; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond [HyperV Technologies Corp., Chantilly, Virginia 20151 (United States)

    2009-08-15

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 {mu}g of plasma with density above 10{sup 17} cm{sup -3} to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 {mu}g has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  2. Turbulent transport in low-beta plasmas

    DEFF Research Database (Denmark)

    Nielsen, A.H.; Pécseli, H.L.; Juul Rasmussen, J.

    1996-01-01

    Low-frequency electrostatic fluctuations are studied experimentally in a low-P plasma, with particular attention to their importance for the anomalous plasma transport across magnetic field lines. The presence of large coherent structures in a turbulent background at the edge of the plasma column...... is demonstrated by a statistical analysis. The importance of these structures for the turbulent transport is investigated. The study is extended by a multichannel conditional analysis to illustrate detailed properties and parameter dependences of the turbulent transport. (C) 1996 American Institute of Physics....

  3. Plasma Colloquium Travel Grant Program

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1998-01-01

    OAK B188 Plasma Colloquium Travel Grant Program. The purpose of the Travel Grant Program is to increase the awareness of plasma research. The new results and techniques of plasma research in fusion plasmas, plasma processing space plasmas, basic plasma science, etc, have broad applicability throughout science. The benefits of these results are limited by the relatively low awareness and appreciation of plasma research in the larger scientific community. Whereas spontaneous interactions between plasma scientists and other scientists are useful, a focused effort in education and outreach to other scientists is efficient and is needed. The academic scientific community is the initial focus of this effort, since that permits access to a broad cross-section of scientists and future scientists including undergraduates, graduate students, faculty, and research staff

  4. Characteristics of plasma plume in fiber laser welding of aluminum alloy

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Ming; Chen, Cong; Hu, Ming; Guo, Lianbo; Wang, Zemin, E-mail: zmwang@mail.hust.edu.cn; Zeng, Xiaoyan

    2015-01-30

    Highlights: • Spectroscopic properties of fiber laser induced Al plasma plume are measured. • The plume is usually a metal vapor dominated weakly ionized plasma. • The plume is a strongly ionized plasma after laser power is higher than 5 kW. • Plasma shielding effect must be considered after laser power reaches 5 kW. • Plasma shielding effect is dominated by inverse bremsstrahlung absorption. - Abstract: To understand the laser–matter interaction in fiber laser welding of aluminum alloys, the effects of laser power on the characteristics of fiber laser induced plasma plume were studied by emission spectroscopic analysis firstly. The plasma characteristic parameters including electron temperature, electron density, ionization degree, and inverse bremsstrahlung linear absorption coefficient were computed according to the spectral data. It was found that the laser power of 5 kW is a turning point. After the laser power reaches 5 kW, the plume changes from a metal vapor dominated weakly ionized plasma to a strongly ionized plasma. The corresponding phenomena are the dramatic increase of the value of characteristic parameters and the appearance of strong plasma shielding effect. The calculation of effective laser power density demonstrated that the plasma shielding effect is dominated by inverse bremsstrahlung absorption. The finding suggested the plasma shielding effect must be considered in fiber laser welding of aluminum alloys, rather than is ignored as claimed in previous view.

  5. [Plasma properties: Annual report

    International Nuclear Information System (INIS)

    1987-01-01

    The Magneto-Fluid Dynamics Division of the Courant Institute is engaged in a broad program of basic research in the theoretical aspects of plasma physics and magneto-fluid dynamics with emphasis on those areas which are relevant to the fusion energy program. The total research program in the division includes efforts in the areas of plasma containment, stability, equilibrium, transport, wave propagation (including shock waves), heating, orbit theory, as well as numerical experiments and the development of practical numerical methods in all plasma problems. Applications are made to the following project areas: Tokamaks, Mirrors, Stellarators, and Alternate Concepts. Developments include the whole spectrum of models from macroscopic MHD and guiding center to Vlasov, drift kinetic Fokker-Planck, and Boltzmann. This document describes research completed as well as programs in progress

  6. MHD analysis of LHD high beta plasma

    International Nuclear Information System (INIS)

    Ichiguchi, K.; Nakajima, N.; Carreras, B.A.

    2003-01-01

    The nonlinear behavior of the interchange mode in the LHD plasma depends on the overlap of the vortices with different helicity. If the vortices are separated in the radial direction, each mode saturates mildly with generating the local flat regions in the pressure profile. In the case of the significant overlap of the vortices, the convection is enhanced and the sudden global reduction of the pressure occurs. Succession of the saturated pressure profile in the increase of beta can suppress the overlap. Self-organization of the pressure profile to suppress the overlap of the vortices can be the stabilizing mechanism in the LHD plasma. (orig.)

  7. Reference data for plasma shaping and magnetic separatrix formation in the JET poloidal field system

    International Nuclear Information System (INIS)

    Lazzaro, E.; Keegan, B.

    1986-01-01

    The analysis and the design of special equilibrium configurations (plasma with separatrix boundary) can be greatly simplified by a chart of the response of the plasma to currents in the poloidal field coils. This note presents this information for some interesting cases, namely for elongated plasmas eventually transformed into double null or in single null separatrix configurations. The calculations are made using the latest edition of the JET equilibrium code ''INVERSX'' including the detailed permeability characteristics of the iron core. (author)

  8. Technological uses of low temperature plasmas

    International Nuclear Information System (INIS)

    Lawton, J.

    1975-01-01

    Types of low temperature plasma sources considered include; arc discharge, high pressure discharge, low pressure discharge and flame. The problems of uniform heating of a gas are discussed and it is considered that the most reliable technique is the magnetically rotated arc, but expanded discharges of one kind or another are likely to be serious competitors in the future. The uses of low temperature plasma in chemistry and combustion are considered. The potential for plasma chemistry lies with processes in which the reactions occur in the plasma itself or its neighbouring gas phase, including those which require the vaporization of liquefaction of a refractory material and also highly endothermic reactions. The production of thixotropic silica and acetylene are discussed as examples of such reactions. The field of plasma and combustion including; ignition, flame ionization and soot formation, and the MHD generator, is considered. (U.K.)

  9. Injection of a coaxial-gun-produced magnetized plasma into a background helicon plasma

    Science.gov (United States)

    Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott

    2014-10-01

    A compact coaxial plasma gun is employed for experimental investigation of plasma bubble relaxation into a lower density background plasma. Experiments are being conducted in the linear device HelCat at UNM. The gun is powered by a 120-uF ignitron-switched capacitor bank, which is operated in a range of 5 to 10 kV and 100 kA. Multiple diagnostics are employed to investigate the plasma relaxation process. Magnetized argon plasma bubbles with velocities 1.2Cs, densities 1020 m-3 and electron temperature 13eV have been achieved. The background helicon plasma has density 1013 m-3, magnetic field from 200 to 500 Gauss and electron temperature 1eV. Several distinct operational regimes with qualitatively different dynamics are identified by fast CCD camera images. Additionally a B-dot probe array has been employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify plasma bubble configurations. Experimental data and analysis will be presented.

  10. 3-D MHD modeling and stability analysis of jet and spheromak plasmas launched into a magnetized plasma

    Science.gov (United States)

    Fisher, Dustin; Zhang, Yue; Wallace, Ben; Gilmore, Mark; Manchester, Ward; Arge, C. Nick

    2016-10-01

    The Plasma Bubble Expansion Experiment (PBEX) at the University of New Mexico uses a coaxial plasma gun to launch jet and spheromak magnetic plasma configurations into the Helicon-Cathode (HelCat) plasma device. Plasma structures launched from the gun drag frozen-in magnetic flux into the background magnetic field of the chamber providing a rich set of dynamics to study magnetic turbulence, force-free magnetic spheromaks, and shocks. Preliminary modeling is presented using the highly-developed 3-D, MHD, BATS-R-US code developed at the University of Michigan. BATS-R-US employs an adaptive mesh refinement grid that enables the capture and resolution of shock structures and current sheets, and is particularly suited to model the parameter regime under investigation. CCD images and magnetic field data from the experiment suggest the stabilization of an m =1 kink mode trailing a plasma jet launched into a background magnetic field. Results from a linear stability code investigating the effect of shear-flow as a cause of this stabilization from magnetic tension forces on the jet will be presented. Initial analyses of a possible magnetic Rayleigh Taylor instability seen at the interface between launched spheromaks and their entraining background magnetic field will also be presented. Work supported by the Army Research Office Award No. W911NF1510480.

  11. [Purification of human goose-type lysozyme 2 (HLysG2) from human seminal plasma and analysis of its enzymatic properties].

    Science.gov (United States)

    Huang, Peng; Yang, Zhifang; Bao, Jianying; Zhang, Ning; Li, Wenshu

    2017-03-01

    Objective To purify human goose-type lysozyme 2 (HLysG2) from human seminal plasma by chromatography and analyze its enzymatic properties. Methods The distribution of HLysG2 in semen was analyzed by Western blot analysis. Seminal plasma was subjected to the separation of target protein using cation-exchange chromatography, chitin affinity chromatography and size-exclusion chromatography. The purified product was identified by Western blot analysis and mass spectrometry (MS).The purity was analyzed by high performance liquid chromatography (HPLC). Then, the optimum pH, ion concentration and temperature of HLysG2 and its standard activity were determined by the turbidimetric assay. The bactericidal activity of HLysG2 was assessed by the colony-forming assay. Results The existence of HLysG2 in seminal plasma was confirmed by Western blot analysis. A protein of about 21.5 kDa was purified from seminal plasma by the three kinds of chromatography and identified as HLysG2 by Western blot analysis and MS. The final purity of the purified product was above 99.0% and the peak enzymatic activity reached 13 800 U/mg under the condition of pH 6.4, 0.09 mol/L Na + , 30DegreesCelsius. In vitro assay indicated that HLysG2 had a significant killing effect on Micrococcus lysodeikticus, Bacillus subtilis and Staphylococcus aureus, but not on Pseudomonas aeruginosa and Escherichia coli. Conclusion Native HLysG2 can be obtained from seminal plasma by chromatography. It has in vitro bactericidal activity against Gram-positive bacteria, suggesting that it might play a role in innate immunity of the male reproductive system.

  12. Application of Plackett-Burman and Doehlert designs for optimization of selenium analysis in plasma with electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    El Ati-Hellal, Myriam; Hellal, Fayçal; Hedhili, Abderrazek

    2014-10-01

    The aim of this study was the optimization of selenium determination in plasma samples with electrothermal atomic absorption spectrometry using experimental design methodology. 11 variables being able to influence selenium analysis in human blood plasma by electrothermal atomic absorption spectrometry (ETAAS) were evaluated with Plackett-Burman experimental design. These factors were selected from sample preparation, furnace program and chemical modification steps. Both absorbance and background signals were chosen as responses in the screening approach. Doehlert design was used for method optimization. Results showed that only ashing temperature has a statistically significant effect on the selected responses. Optimization with Doehlert design allowed the development of a reliable method for selenium analysis with ETAAS. Samples were diluted 1/10 with 0.05% (v/v) TritonX-100+2.5% (v/v) HNO3 solution. Optimized ashing and atomization temperatures for nickel modifier were 1070°C and 2270°C, respectively. A detection limit of 2.1μgL(-1) Se was obtained. Accuracy of the method was checked by the analysis of selenium in Seronorm™ Trace element quality control serum level 1. The developed procedure was applied for the analysis of total selenium in fifteen plasma samples with standard addition method. Concentrations ranged between 24.4 and 64.6μgL(-1), with a mean of 42.6±4.9μgL(-1). The use of experimental designs allowed the development of a cheap and accurate method for selenium analysis in plasma that could be applied routinely in clinical laboratories. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. X-ray structural analysis of plasma sprayed europium oxide

    Energy Technology Data Exchange (ETDEWEB)

    Gorshkov, B.N.; Loskutov, V.S.; Gavrish, A.A.; Shakh, G.E.

    1981-12-01

    An X-ray structure microanalysis is made for europium oxide powder produced by sintering and plasmic spheroidization for plasma spraying. The technique of concern is shown not to alter chemical composition of the powder. It is stated that a rise in the plasma jet enthalpy while spraying does not result in dissociation of europium oxide and its interaction with the plasma flux. The coating (to 15.2 kWxs/g) is found to have only a high-temperature (monoclinic) europium oxide phase and there appears a low-temperature (cubic) phase with a subsequent increase in the enthalpy. The plasma jet enthalpy increasing the grain size and the crystal lattice c parameter of the sprayed europium oxide are shown to decrease; the a parameter reduces with an enthalpy growth to 16.2 kW s/g and then smoothly increases with the enthalpy further growth. It is noticed that the europium oxide coating does not interact with an aluminium D16 alloy substrate.

  14. Radioimmunoassay of plasma progesterone

    Energy Technology Data Exchange (ETDEWEB)

    Langer, L; Veleminsky, J [Institute of Clinical Endocrinology, Lubochna (Czechoslovakia); Hampl, R; Starka, L [Vyzkumny Ustav Endokrinologicky, Prague (Czechoslovakia); Holan, J [Comenius Univ., School of Medicine, Martin (Czechoslovakia). Dept. of Physics and Nuclear Medicine

    1978-06-30

    A simple modification of plasma progesterone radioimmunoassay is described. 11..cap alpha..-Hydroxyprogesterone hemisuccinate - BSA conjugate was used as an immunogen. (1,2,6,7-H-3) Progesterone specific radioactivity 82 Ci.mmol/sup -1/ was purchased from Radiochemical Centre Amersham (England). The method has been applied for the analysis of more than 2000 plasma samples. The typical fluctuation of progesterone in plasma during the menstrual cycle, using data obtained with this method is illustrated. The reliability criteria of the method are given.

  15. Diagnostics of MCF plasmas using Lyman-α fluorescence excited by one or two photons

    International Nuclear Information System (INIS)

    Voslamber, D.

    1998-11-01

    Laser-induced Lyman-α fluorescence of the hydrogen isotopes is investigated with regard to diagnostic applications in magnetically confined fusion plasmas. A formal analysis is presented for two excitation schemes: one-photon and Doppler-free two-photon excitation. The analysis includes estimates of the expected experimental errors arising from the photon noise and from the sensitivity of the observed fluorescence signals to variations of the plasma and laser parameters. Both excitation schemes are suitable primarily for application in the plasma edge, but even in the plasma bulk of large machines they can still be applied in combination with a diagnostic neutral beam. The two-photon excitation scheme is particularly attractive because it involves absorption spectra that are resolved within the Doppler width. This implies a large diagnostic potential and in particular offers a way to measure the deuterium-tritium fuel mix in fusion reactors. (author)

  16. Plasma contactor development for Space Station

    Science.gov (United States)

    Patterson, Michael J.; Hamley, John A.; Sarmiento, Charles J.; Manzella, David H.; Sarver-Verhey, Timothy; Soulas, George C.; Nelson, Amy

    1993-01-01

    Plasma contactors have been baselined for the Space Station (SS) to control the electrical potentials of surfaces to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and, in particular, the technology development effort on ion thrustor systems. The plasma contactor subsystems include the plasma contactor unit, a power electronics unit, and an expellant management unit. Under this pre-flight development program these will all be brought to breadboard or engineering model status. Development efforts for the plasma contactor include optimizing the design and configuration of the contactor, validating its required lifetime, and characterizing the contactor plume and electromagnetic interference. The plasma contactor unit design selected for the SS is an enclosed keeper, xenon hollow cathode plasma source. This paper discusses the test results and development status of the plasma contactor unit subsystem for the SS.

  17. Analysis of neon soft x-ray spectra from short-pulse laser-produced plasmas

    International Nuclear Information System (INIS)

    Abare, A.C.; Keane, C.J.; Crane, J.K.; DaSilva, L.B.; Lee, R.W.; Perry, M.D.; Falcone, R.W.

    1993-04-01

    We report preliminary results from the analysis of streaked soft x-ray neon spectra a gas jet target. In obtained from the interaction of a picosecond Nd:glass laser with these experiments streaked spectra show prompt harmonic emission followed by longer time duration soft x-ray line emission. The majority of the line emission observed was found to originate from Li- and Be-like Ne and the major transitions in the observed spectra have been identified. Li-like emission lines were observed to decay faster in time than Be-like transitions, suggesting that recombination is taking place. Line ratios of n=4-2 and n=3-2 transitions supported the view that these lines were optically thin and thick, respectively. The time history of Li-like Ne 2p-4d and 2p-3d lines is in good agreement with a simple adiabatic expansion model coupled to a time dependent collisional-radiative code. Further x-ray spectroscopic analysis is underway which is aimed at diagnosing plasma conditions and assessing the potential of this recombining neon plasma as a quasi-steady-state recombination x-ray laser medium

  18. Stabilization of external kink modes in a tokamak with rotating plasma

    International Nuclear Information System (INIS)

    Mikhailovskii, A.B.; Kuvshinov, B.N.

    1995-01-01

    An analytical theory of stabilization of external kink modes in a tokamak with rotating plasma is developed, which is of interest in connection with experiments on the DIII-D tokamak demonstrating such a stabilization. It is assumed that, in addition to the main poloidal harmonic, the mode includes one or more side-band poloidal harmonics with singular points lying inside the plasma. Near these singular points, plasma inertia and related toroidal effects, the compressible part of plasma pressure and longitudinal viscosity, are allowed for. These effects are described kinetically taking into account the toroidal trapping of the resonant ions, which is essential if the toroidal velocity is small compared to the ion thermal velocity. Thereby, the theory presented includes both ion Landau damping and its weakening due to toroidal trapping. Near the singular points high-beta effects, which result in the finiteness of the Mercier index s, are allowed for. It is shown that the influence of plasma rotation on the external kink modes is most significant in the case of s<0, i.e., when the development of the instability in a non-rotating plasma is most highly favored. In this case, the plasma rotation plays a stabilizing role, even when the ion Landau damping is neglected. The analysis presented also confirms the hypothesis of Bondeson and Ward on the stabilizing effect of ion Landau damping if this damping is not too small

  19. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma.

    Science.gov (United States)

    Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima

    2017-01-01

    Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  20. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma

    Directory of Open Access Journals (Sweden)

    Ana Paula Barbosa do Carmo

    Full Text Available Abstract INTRODUCTION: Primaquine (PQ diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV analysis of PQ in the blood plasma was developed and validated. METHODS: After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80 (45:55 as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD and quantification (LOQ limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral PQ diphosphate. RESULTS: By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. CONCLUSIONS: The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  1. Plasma Etching for Failure Analysis of Integrated Circuit Packages

    NARCIS (Netherlands)

    Tang, J.; Schelen, J.B.J.; Beenakker, C.I.M.

    2011-01-01

    Plastic integrated circuit packages with copper wire bonds are decapsulated by a Microwave Induced Plasma system. Improvements on microwave coupling of the system are achieved by frequency tuning and antenna modification. Plasmas with a mixture of O2 and CF4 showed a high etching rate around 2

  2. Integrated core-SOL simulations of L-mode plasma in ITER and Indian demo

    International Nuclear Information System (INIS)

    Wisitsorasak, Apiwat; Onjun, Thawatchai; Kanjanaput, Wittawat

    2015-01-01

    Core-SOL simulations are carried out using 1.5D BALDUR integrated predictive modeling code to investigate tokamak plasma in ITER and Indian DEMO reactors operating in low confinement mode (L-Mode). In each simulation, the plasma current, temperature, and density profiles in both core and SOL region are evolved self-consistency. The SOL is simulated by integrating the fluid equations, including sources, along the field lines. The solutions in SOL subsequently provide as the boundary conditions of core plasma region on low-confinement mode. The core plasma transport model is described using a combination of anomalous transport by Multi-Mode-Model version 2001 (MMM2001) and neoclassical transport calculated by NCLASS module together with the toroidal velocity based on the torque due to Neoclassical Toroidal Viscosity (NTV). In addition, a sensitivity analysis is explored by varying plasma parameters, such as plasma density and auxiliary heating power. Furthermore, the ignition tests are conducted to observed plasma response in each design after shutting down an auxiliary heating. (author)

  3. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    Science.gov (United States)

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  4. Dynamic plasma screening effects on electron capture process in hydrogenic ion fully stripped ion collisions in dense plasmas

    International Nuclear Information System (INIS)

    Jung, Y.

    1997-01-01

    In dense plasmas, dynamic plasma screening effects are investigated on electron capture from hydrogenic ions by past fully stripped ions. The classical Bohr Lindhard model has been applied to obtain the electron capture probability. The interaction potential in dense plasmas is represented in terms of the longitudinal dielectric function. The classical straight-line trajectory approximation is applied to the motion of the projectile ion in order to visualize the electron capture probability as a function of the impact parameter, projectile energy, and plasma parameters. The electron capture probability including the dynamic plasma screening effect is always greater than that including the static plasma screening effect. When the projectile velocity is smaller than the electron thermal velocity, the dynamic polarization screening effect becomes the static plasma screening effect. When the projectile velocity is greater than the plasma electron thermal velocity, the interaction potential is almost unshielded. The difference between the dynamic and static plasma screening effects is more significant for low energy projectiles. It is found that the static screening formula obtained by the Debye Hueckel model overestimates the plasma screening effects on the electron capture processes in dense plasmas. copyright 1997 American Institute of Physics

  5. Microscopic Motion of Liquid Metal Plasma Facing Components In A Diverted Plasma

    International Nuclear Information System (INIS)

    Jaworski, M.A.; Gerhardt, S.P.; Morley, N.B.; Abrams, T.; Kaita, R.; Kallman, J.; Kugel, H.; Majeski, R.; Ruzic, D.N.

    2010-01-01

    Liquid metal plasma facing components (PFCs) have been identified as an alternative material for fusion plasma experiments. The use of a liquid conductor where significant magnetic fields are present is considered risky, with the possibility of macroscopic fluid motion and possible ejection into the plasma core. Analysis is carried out on thermoelectric magnetohydrodynamic (TEMHD) forces caused by temperature gradients in the liquid-container system itself in addition to scrape-off-layer currents interacting with the PFC from a diverted plasma. Capillary effects at the liquid-container interface will be examined which govern droplet ejection criteria. Stability of the interface is determined using linear stability methods. In addition to application to liquidmetal PFCs, thin film liquidmetal effects have application to current and future devices where off-normal events may liquefy portions of the first wall and other plasma facing components.

  6. Theory of field-reversed mirrors and field-reversed plasma-gun experiments. Paper IAEA-CN-38/R-2

    International Nuclear Information System (INIS)

    Anderson, D.V.; Auerbach, S.P.; Berk, H.L.

    1980-01-01

    Experimental and theoretical studies of field reversal in a mirror machine are reported. Plasma-gun experiments demonstrate that reversed-field plasma layers are formed. Low energy plasma flowing behind the initially produced plasma front prevents tearing of the layer from the gun muzzle. MHD simulation shows that tearing can be obtained by impeding the slow plasma flow with a plasma divider. It is demonstrated theoretically that a field-reversed mirror imbedded in a multipole field can be sustained in steady state with neutral-beam injection even in the absence of impurities. MHD stability analysis shows that growth rates of elongated reversed-field theta-pinch configurations decrease with axial extension, which indicates the importance of including finite Larmor radius in the analysis. Tilting-mode criteria are improved by proper shaping, and a problimak shape is proposed. Tearing mode stability of reversed-field theta-pinches is greatly enhanced by flux exclusion. Self-consistent, 1-1/2-dimensional transport codes have been developed, and initial results are presented

  7. Theory of field-reversed mirrors and field-reversed plasma-gun experiments. Paper IAEA-CN-38/R-2

    International Nuclear Information System (INIS)

    Anderson, D.V.; Auerbach, S.P.; Berk, H.L.

    1980-01-01

    Experimental and theoretical studies of field reversal in a mirror machine are reported. Plasma-gun experiments demonstrate that reversed-field plasma layers are formed. Low energy plasma flowing behind the initially produced plasma front prevents tearing of the layer from the gun muzzle. MHD simulation shows that tearing can be obtained by impeding the slow plasma flow with a plasma divider. It is demonstrated theoretically that a field-reversed mirror imbedded in a multipole field can be sustained in steady state with neutral-beam injection even in the absence of impurities. MHD stability analysis shows that growth rates of elongated reversed-field theta-pinch configurations decrease with axial extension, which indicates the importance of including finite Larmor radius in the analysis. Tilting-mode criteria are dramatically improved by proper shaping, and a problimak shape is proposed. Tearing mode stability of reversed-field theta-pinches is greatly enhanced by flux exclusion. Self-consistent, 1-1/2-dimensional transport codes have been developed, and initial results are presented

  8. Experimental Plasma Research project summaries

    International Nuclear Information System (INIS)

    1980-09-01

    This report contains descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Diagnostics; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report

  9. Experimental Plasma Research project summaries

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This report contains descriptions of the activities supported by the Experimental Plasma Research Branch of APP. The individual project summaries were prepared by the principal investigators and include objectives and milestones for each project. The projects are arranged in six research categories: Plasma Properties; Plasma Heating; Plasma Diagnostics; Atomic, Molecular and Nuclear Physics; Advanced Superconducting Materials; and the Fusion Plasma Research Facility (FPRF). Each category is introduced with a statement of objectives and recent progress and followed by descriptions of individual projects. An overall budget summary is provided at the beginning of the report.

  10. Waves and Oscillations in Plasmas

    CERN Document Server

    Pecseli, Hans L

    2012-01-01

    The result of more than 15 years of lectures in plasma sciences presented at universities in Denmark, Norway, and the United States, Waves and Oscillations in Plasmas addresses central issues in modern plasma sciences. The book covers fluid models as well as kinetic plasma models, including a detailed discussion of, for instance, collisionless Landau damping. Offering a clear separation of linear and nonlinear models, the book can be tailored for readers of varying levels of expertise.Designed to provide basic training in linear as well as nonlinear plasma dynamics, and practical in areas as d

  11. Easy, Fast, and Reproducible Quantification of Cholesterol and Other Lipids in Human Plasma by Combined High Resolution MSX and FTMS Analysis

    Science.gov (United States)

    Gallego, Sandra F.; Højlund, Kurt; Ejsing, Christer S.

    2018-01-01

    Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MSALL technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133-148 [1]) to support in-depth structural elucidation of lipid molecules. [Figure not available: see fulltext.

  12. Energy deposition of heavy ions in the regime of strong beam-plasma correlations.

    Science.gov (United States)

    Gericke, D O; Schlanges, M

    2003-03-01

    The energy loss of highly charged ions in dense plasmas is investigated. The applied model includes strong beam-plasma correlation via a quantum T-matrix treatment of the cross sections. Dynamic screening effects are modeled by using a Debye-like potential with a velocity dependent screening length that guarantees the known low and high beam velocity limits. It is shown that this phenomenological model is in good agreement with simulation data up to very high beam-plasma coupling. An analysis of the stopping process shows considerably longer ranges and a less localized energy deposition if strong coupling is treated properly.

  13. Field desorption and field ion surface studies of samples exposed to the plasmas of PLT and ISX

    International Nuclear Information System (INIS)

    Kellogg, G.L.; Panitz, J.A.

    1978-01-01

    Modifications to the surface of field-ion specimens exposed to plasma discharges in PLT and ISX determined by Imaging Probe, Field Ion Microscope, and Transmission Electron Microscope analysis have in the past shown several consistent features. Surface films consisting primarily of limiter material with trapped plasma and impurity species have been found to reside on samples with direct line of sight exposure to the plasma during the discharges. Control specimens placed in the tokamak, but shielded from the plasma, on the other hand, remained free of deposits. When exposed to only high power plasma discharges, samples placed at the wall position in PLT and ISX have survived the exposures with no evidence of damage or implantation. In this paper we describe the results of a recent exposure in PLT in which for the first time samples of stainless steel were included for High-Field Surface Analysis. Tokamak operating conditions, including stainless-steel limiters, titanium gettering between discharges, and the occurrence of a disruption, also distinguished this exposure from those carried out previously. Surprisingly, even with stainless-steel limiters, carbon films were found to be deposited on the samples at a rate

  14. Electron cyclotron resonance plasma photos

    Energy Technology Data Exchange (ETDEWEB)

    Racz, R.; Palinkas, J. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary); University of Debrecen, H-4010 Debrecen, Egyetem ter 1 (Hungary); Biri, S. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary)

    2010-02-15

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  15. Electron cyclotron resonance plasma photos

    International Nuclear Information System (INIS)

    Racz, R.; Palinkas, J.; Biri, S.

    2010-01-01

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  16. Computational image analysis of Suspension Plasma Sprayed YSZ coatings

    Directory of Open Access Journals (Sweden)

    Michalak Monika

    2017-01-01

    Full Text Available The paper presents the computational studies of microstructure- and topography- related features of suspension plasma sprayed (SPS coatings of yttria-stabilized zirconia (YSZ. The study mainly covers the porosity assessment, provided by ImageJ software analysis. The influence of boundary conditions, defined by: (i circularity and (ii size limits, on the computed values of porosity is also investigated. Additionally, the digital topography evaluation is performed: confocal laser scanning microscope (CLSM and scanning electron microscope (SEM operating in Shape from Shading (SFS mode measure surface roughness of deposited coatings. Computed values of porosity and roughness are referred to the variables of the spraying process, which influence the morphology of coatings and determines the possible fields of their applications.

  17. Dusty-Plasma Particle Accelerator

    Science.gov (United States)

    Foster, John E.

    2005-01-01

    A dusty-plasma apparatus is being investigated as means of accelerating nanometer- and micrometer-sized particles. Applications for the dusty-plasma particle accelerators fall into two classes: Simulation of a variety of rapidly moving dust particles and micrometeoroids in outer-space environments that include micrometeoroid streams, comet tails, planetary rings, and nebulae and Deposition or implantation of nanoparticles on substrates for diverse industrial purposes that could include hardening, increasing thermal insulation, altering optical properties, and/or increasing permittivities of substrate materials. Relative to prior apparatuses used for similar applications, dusty-plasma particle accelerators offer such potential advantages as smaller size, lower cost, less complexity, and increased particle flux densities. A dusty-plasma particle accelerator exploits the fact that an isolated particle immersed in plasma acquires a net electric charge that depends on the relative mobilities of electrons and ions. Typically, a particle that is immersed in a low-temperature, partially ionized gas, wherein the average kinetic energy of electrons exceeds that of ions, causes the particle to become negatively charged. The particle can then be accelerated by applying an appropriate electric field. A dusty-plasma particle accelerator (see figure) includes a plasma source such as a radio-frequency induction discharge apparatus containing (1) a shallow cup with a biasable electrode to hold the particles to be accelerated and (2) a holder for the substrate on which the particles are to impinge. Depending on the specific design, a pair of electrostatic-acceleration grids between the substrate and discharge plasma can be used to both collimate and further accelerate particles exiting the particle holder. Once exposed to the discharge plasma, the particles in the cup quickly acquire a negative charge. Application of a negative voltage pulse to the biasable electrode results in the

  18. Complex ray analysis for plasmas

    International Nuclear Information System (INIS)

    Connor, K.A.

    1980-01-01

    An extension of ray tracing techniques is considered for a variety of cases in which the dispersion relation of the plasma medium is complex. The ray trajectories are permitted to begin and/or at least travel through complex space-time; the wave propagation process so characterized becomes significant only where the rays intersect real space-time. It is found that rules and guidelines can be established for limited application of this idea

  19. Analysis of bauxite by inductively coupled plasma-atomic emission spectroscopy

    Science.gov (United States)

    Barnes, Ramon M.; Mahanti, Himansu S.

    Methods are described for the analysis of bauxite by inductively coupled plasma (ICP) emission spectroscopy. Bauxite samples were dissolved either in HCl, HNO 3, and HF at 160°C in all-PTFE bomb or fused with NaOH. Spectral lines were selected after examination of experimental wavelength scans at each potential analyte wavelength. Limits of detection, background equivalent concentration, and analytical figures of merit were established. The accuracy of the method was confirmed by determining 17 elements in NBS-SRM bauxite samples. Silicon in HF solutions was analyzed using a modified ICP torch with a graphite injector tube, an inert nebulizer using PTFE capillary tubes, and a PTFE spray chamber.

  20. ECR Plasma Photos

    International Nuclear Information System (INIS)

    Racz, R.; Biri, S.; Palinkas, J.

    2009-01-01

    Complete text of publication follows. In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from He, methane, N, O, Ne, Ar, Kr, Xe gases and from their mixtures. The effects of the main external setting parameters (gas pressure, gas composition, magnetic field, microwave power, microwave frequency) were studied to the shape, color and structure of the plasma. The double frequency mode (9+14 GHz) was also realized and photos of this special 'star-in-star' shape plasma were recorded. A study was performed to analyze and understand the color of the ECR plasmas. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas. To our best knowledge our work is the first systematic study of ECR plasmas in the visible light region. When looking in the plasma chamber of an ECRIS we can see an axial image of the plasma (figure 1) in conformity with experimental setup. Most of the quantitative information was obtained through the summarised values of the Analogue Digital Unit (ADU) of pixels. By decreasing the strength of the magnetic trap we clearly observed that the brightness of the central part of the plasma gradually decreases, i.e. the plasma becomes more and more 'empty'. Figure 2 shows a photo series of ECR plasma at decreasing axial magnetic field. The radial size of the plasma increased because of the ascendant resonant zone. By increasing the power of the injected microwave an optimum (or at least saturation) was found in the brightness of the plasma. We found correlation between the gas dosing rates and plasma intensities. When sweeping the frequency of the microwave in a wide region