WorldWideScience

Sample records for allogenic anterior lens

  1. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule.

  2. Misdiagnosis induced intraocular lens dislocation in anterior megalophthalmos

    Institute of Scientific and Technical Information of China (English)

    WANG Qi-wei; XU Wen; ZHU Ya-nan; LI Jin-yu; ZHANG Li; YAO Ke

    2012-01-01

    Anterior megalophthalmos (AM) is an uncommon developmental anomaly of the anterior segment of the eye with a constellation of findings that includes enlarged cornea,deep anterior chamber,posterior positioning of the iris and lens,iris stroma atrophy,hypoplasia of iris dilator,pupil displacement,large capsular bag,lens subluxation,prematurely cataract and the tendency to retinal detachment.AM,especially when symptoms are mild,is not an easy disease to diagnose.We present 3 AM cases that were misdiagnosed as congenital cataract with weak zonule and megalocornea.Intraocular lenses (IOLs) dislocated after standard cataract surgeries and subsequent surgery (replacing the dislocated IOLs with iris-claw intraocular lenses) achieved satisfactory outcome.Although rare,AM should be included in the differential diagnosis of enlarged cornea and we recommend implanting Artisan lens in AM patients.

  3. Silicone Oil Tamponade Combined with Lensectomy Preserving Anterior Lens Capsule

    Institute of Scientific and Technical Information of China (English)

    LuL; YangJ

    1999-01-01

    Purpose:To investigate the therapeutic effect and indicatio n of silicone oil tamponade combined with lensectomy preserving anterior lens capsule.Methods:Silicone oil tamponade combined with lensectomy preserving anterior lens capsule was performed in 33 cases (33 eyes)of high myopia ,proliferative vitroretinopathy(PVR)D grade and giant retinal tear(GRT).10 cases were onlyeye and 11 cases had harder nucleus of lens.The surgical methods included:1.smashing lens nucleus and lensectomy preserving complete anterior capsule;2,vitrectomy and membrane peeling;3,usage of liquid perfluorocarbin or retinotomy or drainage;4.silicone oil tamponade;5.postoperative Nd;YAG laser for anterior capsulectomy. Results:Follow-up time was 6 months or more in 29 cases.Total retinal reattachment was achieved in 22 cases,macular retinal reattachment in 5 cases.The visual acuity was 20/800 to 20/200 in 13 cases,20/100 to 20/50 in 12 cases.Visual acuity was significantly improved in GRT group(P<0.05).Complications included unexpected anterior capsule break intraoperatively,anterior capsule opacity,silicone oil emulsification and liquid perfluorocarbin remainig postoperatively.Conclusions:Silicone oil tamponade combined with lensectomy preserving anterior capsule was safe and can reduce the operative complications.The indications included:1.GRT complicated with high myopia;2,advanced PVR cases complicated with high myopia in which silicone oil must be used;3.severe lens opacity cases in which silicone oil must be used;4.complex retinal detachment of only ye.

  4. Multiaxial mechanical behavior of the porcine anterior lens capsule.

    Science.gov (United States)

    Heistand, M R; Pedrigi, R M; Delange, S L; Dziezyc, J; Humphrey, J D

    2005-11-01

    The biomechanics of the lens capsule of the eye is important both in physiologic processes such as accommodation and clinical treatments such as cataract surgery. Although the lens capsule experiences multiaxial stresses in vivo, there have been no measurements of its multiaxial properties or possible regional heterogeneities. Rather all prior mechanical data have come from 1-D pressure-volume or uniaxial force-length tests. Here, we report a new experimental approach to study in situ the regional, multiaxial mechanical behavior of the lens capsule. Moreover, we report multiaxial data suggesting that the porcine anterior lens capsule exhibits a typical nonlinear pseudo-elastic behavior over finite strains, that the in situ state is pre-stressed multi-axially, and that the meridional and circumferential directions are principal directions of strain, which is nearly equi-biaxial at the pole but less so towards the equator. Such data are fundamental to much needed constitutive formulations.

  5. Regional multiaxial mechanical properties of the porcine anterior lens capsule.

    Science.gov (United States)

    David, G; Pedrigi, R M; Heistand, M R; Humphrey, J D

    2007-02-01

    The lens capsule of the eye plays fundamental biomechanical roles in both normal physiological processes and clinical interventions. There has been modest attention given to the mechanical properties of this important membrane, however, and prior studies have focused on 1-D analyses of the data. We present results that suggest that the porcine anterior lens capsule has a complex, regionally dependent, nonlinear, anisotropic behavior. Specifically, using a subdomain inverse finite element method to analyze data collected via a new biplane video-based test system, we found that the lens capsule is nearly isotropic (in-plane) near the pole but progressively stiffer in the circumferential compared to the meridional direction as one approaches the equator. Because the porcine capsule is a good model of the young human capsule, there is strong motivation to determine if similar regional variations exist in the human lens capsule for knowledge of such complexities may allow us to improve the design of surgical procedures and implants.

  6. CATARACT SURGERY AND INTRAOCULAR LENS POWER CALCULATION IN A PATIENT WITH ANTERIOR MEGALOPHTHALMOS WITH NORMAL SIZED CRYSTALLINE LENS; CASE REPORT

    Directory of Open Access Journals (Sweden)

    Glišić Selimir

    2015-12-01

    Full Text Available Cataract surgery and intraocular lens power calculation is challenging in patients with anterior megalophthalmos and cataract, with postoperative refractive surprise frequently reported. Deep anterior chamber in these patients substantially influence effective lens position. To minimize possibility of refractive surprise, we used Haigis formula that takes into account anterior chamber depth in the lens power calculation for our patient. Cataract was managed by phakoemulsification with standard intraocular lens implanted in the capsular bag. Postoperatively, satisfying refractive result was achieved and refractive surprise was avoided.

  7. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  8. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens.

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  9. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Oriel Spierer

    2016-05-01

    Full Text Available A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  10. Anterior iris-claw lens implantation with single paracentesis

    Directory of Open Access Journals (Sweden)

    Ahmet Özer

    2011-11-01

    Full Text Available In this study, the technique and results of iris-claw intraocular lens (IOL implantation with corneal incision and single paracentesis were presented. Eighteen eyes of 18 patients who underwent iris-claw implantation surgery with a single paracentesis were included in this prospective study. Iris-claw lens was grasped by its forceps and placed into the anterior chamber through superior corneal opening. While IOL was held by forceps, a blunt enclavation spatula was introduced through inferior paracentesis. Then the spatula was directed toward underneath of iris through pupil and toward sides where iris was entrapped into the claw by gentle push of iris through the slotted center of the lens haptics. Mean age of patients was 54.28±25.21 years (7-76 years. Mean anterior chamber depth was 4.07±0.32 mm and mean keratometric power was 43.01±2.73 D. Preoperative BCVA was 20/63 or better in 8 (44.4% patients. At the first postoperative month BCVA was 20/63 or better in 14 (77.8% patients. Preoperative mean spherical refraction was +11.05±2.62 D, preoperative astigmatism was 2.15±0.85. Postoperative mean spherical refraction was - 0.58±0.25 D and mean astigmatism was - 1.92±0.67 D. The most frequent postoperative complication was mild corneal edema seen in three patients that resolved completely during the first week with medical treatment. Irisclaw IOL implantation can be performed easily with corneal incision and single paracentesis. Single paracentesis does not increase surgical time or cause inconvenience during the procedure.

  11. Anterior lens epithelium in cataract patients with retinitis pigmentosa - scanning and transmission electron microscopy study.

    Science.gov (United States)

    Andjelic, Sofija; Drašlar, Kazimir; Hvala, Anastazija; Hawlina, Marko

    2017-05-01

    In retinitis pigmentosa (RP) patients, relatively minor lens opacity in central part of posterior pole of the lens may cause disproportionate functional symptoms requiring cataract operation. To investigate the possible structural reasons for this opacity development, we studied the structure of the lens epithelium of patients with RP. The anterior lens capsule (aLC: basement membrane and associated lens epithelial cells, LECs) was obtained from cataract surgery and prepared for scanning and transmission electron microscopy (SEM and TEM). Both SEM and TEM show a number of abnormal features in the anterior lens epithelium of cataract patients with RP. The abnormalities appear mainly as holes, thinning and degradation of the epithelium, with the dimensions from <1 μm to more than 50 μm. Other types of holes in size up to 20 μm were seen that may be formed by gradual stretching of the lens epithelium. Another type of abnormalities was cracks that were seen between adjacent LECs, with dimensions 0.1-2 μm × up to 10 μm. Abnormal structural features were observed in the anterior lens epithelium that may cause water influx into the lens. This may lead to clouding along the water clefts leading towards the posterior pole in the RP cataractous lens. We suggest that the lens epithelium has a role in the development of the cataract in patients with RP. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Anterior Chamber Iris Claw Lens for the Treatment of Aphakia in a Patient with Megalocornea

    Science.gov (United States)

    Saffra, Norman; Rakhamimov, Aleksandr; Masini, Robert; Rosenthal, Kenneth J.

    2015-01-01

    Megalocornea in isolation is a rare congenital enlargement of the cornea greater than 13 mm in diameter. Patients with megalocornea are prone to cataract formation, crystalline lens subluxation, zonular deficiencies and dislocation of the posterior chamber intraocular lens (PCIOL) within the capsular bag. A 55-year-old male with megalocornea in isolation developed subluxation of the capsular bag and PCIOL. The PCIOL and capsular bag were explanted, and the patient was subsequently implanted with an anterior chamber iris claw lens. An anterior chamber iris claw lens is an effective option for the correction of aphakia in patients with megalocornea. PMID:26120314

  13. Treatment Approach to Small Inadvertent Injury of the Crystalline Lens Anterior Capsule During Iridodialysis Repair Surgery

    Directory of Open Access Journals (Sweden)

    Gökçen Gökçe

    2013-01-01

    Full Text Available A 22-year-old man presented to our ophthalmology department with photophobia. On ophthalmic examination, iridodialysis secondary to blunt trauma that occurred 5 years ago was diagnosed. During iridodialysis repair surgery, long curved double-armed needle of 10-0 polypropylene suture (PC-9 inserted into the 19 gauge side port turned down inadvertently by its own weight, resulting in crystalline lens anterior capsule perforation. Postoperative clinical observation revealed no lens opacification affecting visual acuity. This case report showed that lens aspiration surgery should be postponed if the capsule injury is small.(Turk J Ophthalmol 2013; 43: 61-3

  14. Fifty-year follow-up and Strampelli anterior chamber intraocular lens.

    Science.gov (United States)

    Oakley, Carmen L; Nigro, Matthew A; Vote, Brendan J

    2015-01-01

    The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era. The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era.

  15. Bilateral spontaneous rupture of anterior lens capsules in a middle-aged woman

    Directory of Open Access Journals (Sweden)

    Hemalatha C

    2012-11-01

    Full Text Available Chandrakanthan Hemalatha,1,2 Hamzah Norhafizah,1 Ismail Shatriah21Department of Ophthalmology, Hospital Tengku Ampuan Rahimah, Selangor, Malaysia; 2Department of Ophthalmology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, MalaysiaAbstract: Hypermature cataracts are commonly seen in developing countries. Spontaneous rupture of the anterior capsule, resulting in dislocation of the lens nucleus into the anterior chamber, presents rarely in hypermature cataracts. We describe a middle-aged woman who presented with spontaneous anterior dislocation of the nucleus in both eyes. The presence of calcification spots in the posterior capsule at the pupillary edge strongly suggested that our patient had hypermature cataracts. It is important to highlight this uncommon cause of nucleus dislocation in a patient with no previous history of ocular trauma.Keywords: dislocation of the nucleus, anterior chamber, hypermature cataract

  16. Surgical Management of a Patient with Anterior Megalophthalmos, Lens Subluxation, and a High Risk of Retinal Detachment

    Science.gov (United States)

    Esteve, María Carmen Guixeres; Pardo Saiz, Augusto Octavio; Martínez-Costa, Lucía; Dorta, Samuel González-Ocampo; Solana, Pedro Sanz

    2017-01-01

    The early development of lens opacities and lens subluxation are the most common causes of vision loss in patients with anterior megalophthalmos (AM). Cataract surgery in such patients is challenging, however, because of anatomical abnormalities. Intraocular lens dislocation is the most common postoperative complication. Patients with AM also seem to be affected by a type of vitreoretinopathy that predisposes them to retinal detachment. We here present the case of a 36-year-old man with bilateral AM misdiagnosed as simple megalocornea. He had a history of amaurosis in the right eye due to retinal detachment. He presented with vision loss in the left eye due to lens subluxation. Following the removal of the subluxated lens, it was deemed necessary to perform a vitrectomy in order to prevent retinal detachment. Seven months after surgery, an Artisan® Aphakia iris-claw lens was implanted in the anterior chamber. Fifteen months of follow-up data are provided. PMID:28203198

  17. Anterior lens epithelium in intumescent white cataracts - scanning and transmission electron microscopy study.

    Science.gov (United States)

    Andjelic, Sofija; Drašlar, Kazimir; Hvala, Anastazija; Hawlina, Marko

    2016-02-01

    Our purpose was to study the structure of the lens epithelial cells (LECs) of intumescent white cataracts (IC) in comparison with nuclear cataracts (NC) in order to investigate possible structural reasons for development of IC. The anterior lens capsule (aLC: basement membrane and associated LECs) were obtained from cataract surgery and prepared for scanning electron microscopy (SEM) and transmission electron microscopy (TEM). We observed by SEM that in IC, LEC swelling was pronounced with the clefts surrounding the groups of LECs. Another structural feature was spherical formations, that were observed on the apical side of LEC's, towards the fibre cell layer, both by SEM and TEM. Development of these structures, bulging out from the apical cell membrane of the LEC's and disrupting it, could be followed in steps towards the sphere formation. The degeneration of the lens epithelium and the structures of the aLC in IC similar to Morgagnian globules were also observed. None of these structural changes were observed in NC. We show by SEM and TEM that, in IC, LECs have pronounced structural features not observed in NC. This supports the hypothesis that the disturbed structure of LECs plays a role in water accumulation in the IC lens. We also suggest that, in IC, LECs produce bulging spheres that represent unique structures of degenerated material, extruded from the LEC.

  18. Perfluorodecaline residue in the anterior chamber of a patient with an intact crystalline lens: a case report

    Directory of Open Access Journals (Sweden)

    Aydin Erdinc

    2008-01-01

    Full Text Available Abstract Background Perfluorocarbon liquids are frequently used as intraoperative tools in vitreoretinal surgery and may occasionally be retained in the vitreous cavity. We report a patient who underwent pars plana vitrectomy for a giant tear after receiving blunt trauma to his right eye and sustained postoperative perfluorocarbon liquid residue in the anterior chamber in spite of an intact crystalline lens. Case presentation Perfluorodecaline was used as a temporary retinal tamponade. Three weeks after the surgery, a residue of heavy liquid was observed in the anterior chamber, even though the patient had an intact crystalline lens without any tilt or dislocation. The remnant of the heavy liquid was taken out of the anterior chamber immediately to avoid secondary complications. Conclusion Presence of heavy liquids in the anterior chamber may be associated with zonular defects even though the patient has an intact crystalline lens.

  19. Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Lucien A. M. van Philips

    2011-01-01

    Full Text Available Toxic anterior segment syndrome (TASS developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL. Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD. These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.

  20. Protective effect of the anterior lens capsule during extracapsular cataract extraction. Part I. Experimental animal study.

    Science.gov (United States)

    Solomon, K D; Gwin, T D; O'Morchoe, D J; Tetz, M R; Hansen, S O; Sugita, A; Imkamp, E M; Apple, D J

    1989-05-01

    In an experimental study using albino Rex rabbits, the intercapsular cataract extraction (ICCE) technique was performed in 20 eyes with a small anterior capsulotomy. A large, can opener capsulotomy was performed in another 20 eyes, and 10 unoperated eyes served as controls. Endothelial cell loss was determined by vital staining with Trypan blue and Alizarin red S stains. Average endothelial cell loss with the ICCE technique was 1.2%; with the can opener technique, the average cell loss was 6.6%. This difference was statistically significant (P less than 0.01). The percentage of endothelial cell loss in the control eyes was 0.5. A positive correlation between endothelial cell loss related to phacoemulsification time and/or the amount of irrigating fluid used existed for the can opener group only (P less than 0.01). These results demonstrate that the presence of an almost intact anterior lens capsule during removal of lens substance is protective to the corneal endothelium.

  1. Aphakia Correction by Injection of Foldable Intra Ocular Lens in The Anterior Chamber

    Science.gov (United States)

    Giles, Kagmeni; Ernest, Moukouri; Christelle, Domngang; Georges, Nguefack-Tsague; Raoul, Cheuteu; Come, Ebana Mvogo; Wiedemann, Peter

    2013-01-01

    We assessed the outcomes of the use of anterior chamber foldable lens for unilateral aphakia correction at the University Teaching Hospital of Yaounde. In this retrospective, non-comparative, consecutive case series study, we reviewed the records of patients who underwent an operation for aphakia correction by the means of injection of an angular supported foldable lens between January 2009 and December 2011 in the University Teaching Hospital Yaounde. Student’s paired t-test was carried out to compare pre-operative and post-operative visual acuity (VA) and intraocular pressure (IOP). P-values less than 0.05 were considered statistically significant. Twenty-one patients were included in the study; twelve were male (57.1%) and nine were female (42.9%). The mean age was 55.38 ± 17.67 years (range 9–75 years). The mean follow-up duration was 5.95 ± 3.14 months (range 2–12 months). The mean log-MAR visual acuity was 1.26 ± 0.46 pre-operatively and 0.78 ± 0.57 post-operatively (P = 0.003). The change in intraocular pressure was not statistically significant. Complications included intraocular hypertension (over 21 mmHg) in 3 patients (14.3%) and macular edema, pupillar ovalization, and retinal detachment in one patient each. The results indicate that injection of an angular support foldable lens in the anterior chamber is a useful technique for the correction of aphakia in eyes without capsular support. More extended follow-up, however, and a larger series of patients are needed to ascertain the effectiveness and safety of this procedure. PMID:24324349

  2. Iris-claw intraocular lens implantation: Anterior chamber versus retropupillary implantation

    Science.gov (United States)

    Helvacı, Sezer; Demirdüzen, Selahaddin; Öksüz, Hüseyin

    2016-01-01

    Purpose: To compare the outcomes of anterior chamber and retropupillary implantation of iris-claw Artisan intraocular lenses (IOL). Design: Prospective, randomized, single-blinded study. Patients and Methods: Forty eyes of forty aphakic patients were enrolled. Patients were randomized into two groups. Each group includes twenty patients. Group 1 received anterior chamber Artisan IOL implantation. Group 2 received retropupillary Artisan IOL implantation. Preoperative and postoperative corrected distance visual acuity (CDVA), intraocular pressure (IOP), and all complications were noted and compared at 6 months follow-up. Results: Each two groups obtained a significant improvement in CDVA (P < 0.05). Four patients in Group 1 and five patients in Group 2 had significant but nonpermanent increase at IOP values. There were one and two pupillary irregularity in Group 1 and Group 2, respectively. In one patient, a shallow and inferior located retinal detachment were encountered in anterior chamber group. Conclusions: The results were not significantly different between the two fixation techniques for iris-claw lens. The surgery procedure is dependent to surgeon experience and eye's conditions. PMID:26953023

  3. Allogeneic versus autologous derived cell sources for use in engineered bone-ligament-bone grafts in sheep anterior cruciate ligament repair.

    Science.gov (United States)

    Mahalingam, Vasudevan D; Behbahani-Nejad, Nilofar; Horine, Storm V; Olsen, Tyler J; Smietana, Michael J; Wojtys, Edward M; Wellik, Deneen M; Arruda, Ellen M; Larkin, Lisa M

    2015-03-01

    The use of autografts versus allografts for anterior cruciate ligament (ACL) reconstruction is controversial. The current popular options for ACL reconstruction are patellar tendon or hamstring autografts, yet advances in allograft technologies have made allogeneic grafts a favorable option for repair tissue. Despite this, the mismatched biomechanical properties and risk of osteoarthritis resulting from the current graft technologies have prompted the investigation of new tissue sources for ACL reconstruction. Previous work by our lab has demonstrated that tissue-engineered bone-ligament-bone (BLB) constructs generated from an allogeneic cell source develop structural and functional properties similar to those of native ACL and vascular and neural structures that exceed those of autologous patellar tendon grafts. In this study, we investigated the effectiveness of our tissue-engineered ligament constructs fabricated from autologous versus allogeneic cell sources. Our preliminary results demonstrate that 6 months postimplantation, our tissue-engineered auto- and allogeneic BLB grafts show similar histological and mechanical outcomes indicating that the autologous grafts are a viable option for ACL reconstruction. These data indicate that our tissue-engineered autologous ligament graft could be used in clinical situations where immune rejection and disease transmission may preclude allograft use.

  4. Anterior chamber fixation of a posterior chamber intraocular lens: A novel technique

    Directory of Open Access Journals (Sweden)

    A Sahap Kükner

    2014-01-01

    Full Text Available We aimed to evaluate the implantation of a posterior chamber intraocular lens (IOL in the anterior chamber (AC with the haptics passing through two iridectomies to the posterior chamber. A total of 33 eyes of 33 patients with inadequate posterior capsular support due to either previous aphakia or posterior capsular rupture during cataract extraction were included in the study. A double iridectomy was performed on all patients using a vitrectomy probe on the midperiphery of the iris. IOLs were implanted in the AC, and the haptics were passed through the iridectomies to the posterior chamber. The mean follow-up time was 25.3 months. AC hemorrhage occurred in five patients during the iridectomy procedure. Corneal edema was detected in eight of 14 patients with primary IOL insertions. Haptic dislocation was detected in only one patient. This technique may be a good alternative to scleral-fixated IOL implantation in eyes with aphakia.

  5. The method for staining of anterior lens capsule in cases with small and rigid pupils

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2014-07-01

    Full Text Available Purpose: to evaluate the safety and effectiveness of proposed method for staining with trypan blue anterior lens capsule in cases with small and rigid pupils.Methods: the safety and effectiveness of the proposed method was evaluated in 169 cases having small and rigid pupils of III and IV grade. Surgical steps included: irrigation of anterior chamber with small amount of air, enough to block the pupil; irrigation of posterior chamber with little amount of dye followed by aspiration of air bubble. the excess dye came out and stained the capsule in pupillary area.Results: No difficulty was encountered in irrigating the posterior chamber with dye. Uneven staining of the capsule was noticed in 16 cases (9.5%. In 3 cases (1.8% extensive staining of iris and posterior capsule was observed. Continuous curvilinear capsulorhexis was performed successfully in 97.6% cases. In 4 cases there was radial run of the rhexis extending up to posterior capsule. Postopera- tive inflammation of 1st and 2nd degree was observed in 5.9 and 23.1% cases, which was related to unavoidable trauma to iris tissue during pupil stretching.Conclusion: the proposed method of capsule staining in cases with small and rigid pupils is safe and effective.

  6. The method for staining of anterior lens capsule in cases with small and rigid pupils

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2012-01-01

    Full Text Available Purpose: to evaluate the safety and effectiveness of proposed method for staining with trypan blue anterior lens capsule in cases with small and rigid pupils.Methods: the safety and effectiveness of the proposed method was evaluated in 169 cases having small and rigid pupils of III and IV grade. Surgical steps included: irrigation of anterior chamber with small amount of air, enough to block the pupil; irrigation of posterior chamber with little amount of dye followed by aspiration of air bubble. the excess dye came out and stained the capsule in pupillary area.Results: No difficulty was encountered in irrigating the posterior chamber with dye. Uneven staining of the capsule was noticed in 16 cases (9.5%. In 3 cases (1.8% extensive staining of iris and posterior capsule was observed. Continuous curvilinear capsulorhexis was performed successfully in 97.6% cases. In 4 cases there was radial run of the rhexis extending up to posterior capsule. Postopera- tive inflammation of 1st and 2nd degree was observed in 5.9 and 23.1% cases, which was related to unavoidable trauma to iris tissue during pupil stretching.Conclusion: the proposed method of capsule staining in cases with small and rigid pupils is safe and effective.

  7. Clinical efficacy of micro incision phacoemulsification and intraocular lens implantation in patients with shallow anterior chamber and cataract

    Directory of Open Access Journals (Sweden)

    Xue-Feng Pan

    2016-06-01

    Full Text Available AIM: To investigate the efficacy and safety of phacoemulsification combined with intraocular lens implantation in the treatment of shallow anterior chamber with cataract. METHODS: Retrospective case series. From February 2014 to July 2015 in our hospital,65 eyes in 65 patients with cataract were enrolled and divided into mild and high risk of shallow anterior chamber group. Best-corrected visual acuity(BCVA, intraocular pressure(IOP, central anterior chamber dept(CACD, angle opening distance(AOD, complications pre- and post treatment, were observed and analyzed as outcome measures. RESULTS:In this study, the mild shallow anterior chamber group included 34 eyes; postoperative BCVA were improved in 29 eyes, with 4 eyes remaining stable and decreased in 1 eye; BCVA was improved in 16 eyes, with 10 eyes remaining stable and decreased in 5 eyes in high risk of shallow anterior chamber group postoperatively. BCVA had a better prognosis in the mild shallow anterior chamber group than another group(t=-2.956, Pt=-5.02,-3.04; PF=203.75, PCONCLUSION: Micro incision cataract surgery is useful, effective and safe in patients with cataract and shallow anterior chamber which can stabilize or improve BCVA, reduce IOP, deepen CACD and open the anterior chamber angle.

  8. Anterior segment optical coherence tomography in the assessment of postoperative intraocular lens optic changes.

    Science.gov (United States)

    Werner, Liliana; Michelson, Jennifer; Ollerton, Andrew; Leishman, Lisa; Bodnar, Zachary

    2012-06-01

    To evaluate the use of anterior segment optical coherence tomography (AS-OCT) to assess postoperative intraocular lens (IOL) optic changes. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Intraocular lenses explanted because of various complications were used, including poly(methyl methacrylate) (PMMA) IOLs with snowflake degeneration, hydrophilic acrylic IOLs with calcification, a silicone IOL with calcification from an eye with asteroid hyalosis, and hydrophobic acrylic IOLs explanted because of decentration, subluxation, or uveitis-glaucoma-hyphema syndrome. After gross and light microscopy, the IOLs were examined in the dry and hydrated states using AS-OCT. Selected hydrophilic acrylic IOLs were stained for calcium. In-the-bag IOLs in pseudophakic cadaver eyes were also evaluated by AS-OCT before and after explantation to confirm correspondence with the clinical situation. Intraoptic changes, such as snowflake lesions in PMMA IOLs, calcification in hydrophilic acrylic IOLs, and glistenings in hydrophobic acrylic IOLs, could be imaged by AS-OCT. The method was also helpful in analyzing the location and density. However, in cases of more superficial changes, unless the lesions/deposits were present on the optic surface with an extension to the optic substance of at least 0.1 mm, they could not be clearly differentiated from the overall outline of the IOL surface. Anterior segment OCT may be helpful in assessing the presence, location, and density of intraoptic changes, avoiding a misdiagnosis of IOL opacification and the performance of unnecessary procedures, such as posterior capsulotomy or vitrectomy. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Vitrectomy and translocation of the anterior chamber intraocular lens to the sulcus: a closed microsurgical technique for the UGH syndrome.

    Science.gov (United States)

    Gualtieri, William; Rossini, Paolo; Forlini, Cesare

    2008-01-01

    This interventional case report presents an anterior chamber intraocular lens (AC-IOL) translocation technique to manage a case of uveitis-glaucoma-hyphema (UGH) syndrome associated with posterior dislocation of nuclear fragments and vitreitis as a consequence of capsule rupture during cataract surgery. Pars plana vitrectomy followed by an AC-IOL translocation from the anterior chamber to the sulcus without additional surgical corneal incision was performed. At 12 months' follow-up, the original AC-IOL was in stable position in the posterior chamber, with binocular refractive balance and no further astigmatism and resolution of the UGH syndrome.

  10. An analysis of flexible anterior chamber lenses with special reference to the normalized rate of lens explantation.

    Science.gov (United States)

    Lim, E S; Apple, D J; Tsai, J C; Morgan, R C; Wasserman, D; Assia, E I

    1991-02-01

    A survey of 1204 closed-loop anterior chamber intraocular lenses (AC-IOLs) and 310 open-loop AC-IOLs accessioned between November 1982 and January 1990 was conducted at the Center for Intraocular Lens Research. An analysis of complication rates was done after normalization of data with respect to market share totals. The results establish that an unacceptable complication rate is associated with the closed-loop design when compared with either the tripod or quadripod lens styles. Furthermore, the closed-loop designs, while comprising an estimated 45% of the total number of AC-IOLs estimated to be implanted in the United States (n = 674,000), were responsible for 80% of the AC-IOLs explanted after complications and accessioned at the authors' center. A rethinking of the extreme condemnation of all anterior chamber IOLs that has surfaced in recent years is warranted. This is particularly true with respect to indications for use of sutured posterior chamber (PC) IOLs as well as with regard to possible use of open-loop AC-IOLs in less-industrialized nations.

  11. Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps.

    Science.gov (United States)

    Huang, Yan-Ming; Yan, Hua; Cai, Jin-Hong; Li, Hai-Bo

    2017-01-01

    To introduce a novel approach in removal of anterior chamber angle foreign body (ACFB) using a prism contact lens and 23-gauge foreign body forceps. Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. The success rate of ACFB once removal was 75% (15/20) in group A, and 100% (22/22) in group B. The average operation time of group A was significantly longer compared with group B (34.9±9.88min vs 22.13±8.85min; Pprism contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach.

  12. Doenças do segmento anterior ocular associadas a lentes de contato Contact lens-associated ocular anterior segment diseases

    Directory of Open Access Journals (Sweden)

    Murilo Barreto Souza

    2008-12-01

    Full Text Available A disponibilidade de lentes de contato cada vez mais confortáveis e toleráveis favoreceu não só a ampliação das indicações, mas também o aumento do número de seus usuários. Como conseqüência deste fato as complicações associadas ao uso de lentes de contato são cada vez mais comuns, e representam um problema de grande prevalência na prática clínica. O objetivo deste estudo é revisar as principais doenças e alterações do segmento anterior e superfície ocular associadas ao uso de lentes de contato.Nowadays, contact lenses have shown a larger variety of options in order to meet the needs of different patients. They have become more frequent in the clinical practice and, consequently, the complications related to contact lenses have been more common. This review attempted to describe the main alterations and diseases of the cornea and anterior segment associated with contact lens wearers.

  13. Clinical Observation on Preservation of Lens Anterior Capsule in Reduction of Complications Associated with Silicone Oil

    Institute of Scientific and Technical Information of China (English)

    Zongming Song; Yannian Hui; Lin Wang; Xiaoyan Cao; Qianying Gao

    2001-01-01

    Purpose: To observe the effect of preservation of anterior capsule on the incidence of complications associated with silicone oil. Methods: 82 patients(82 eyes) accepted trans pars plana vitrectomy(TPPV) combined with lensectomy of whom , 30 eyes with preservation of anterior capsule(PAC) and 52eyes with no preservation of anterior capsule (NPAC). Analysis of the incidence of complications associated with use of oil. Results:The incidence rate was 50.0 % in NPAC group, and 23.3 % in PAC group( P < 0. 025 ). There were seconda'y glaucoma (21. 1% ), band keratopathy ( 13.5 % ) and corneal decompensation(9.6 % ) in NPAC group, while there was none of them in PAC group. Conclusions: Preservation of anterior capsule is an eftective method to reduce the complications associated with silicone oil. Eye Science 2001; 17:39 ~ 41.

  14. Nd:YAG Laser Lysis of the Fibrinous Membrane and Remnant Substance on the Anterior Surface of Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    ZhendeLin; ChenjinJin

    1995-01-01

    Purpose:To determine the effects of ND:YAGlaser to disrupt the fibrinous membrane and remnant substance on the anterior surface of intraocular lens.Methods:Nd:YAGlaser was applied on 23cases of fibrinous membrane forma-tion and 8cases of remnant substance on the anterior surface of intaocular lenses(IOL)which had not reponded well to steroid therapy,Eighteen cases were male and 13female.The mean age was49.7years(range,5-78years),The in-terval between IOL implantation and laser therapy was 0.5-30months in the fibrinous membrane cases and 3-10days in the remnant substance cases.The energy applied was0.8-3.0mJ/exp.with2-112exposures.mean follow-up period was3.6months.Results:Complications during therapy included only 2cases of slight iris bleed-ing,Visual acuity after therapy was improved 1line in 16cases,2lines in 11cas-es,3lines in 1case,4lines in 1case and 5lines in 2cases,No post-therapy com-plication was found.Conclusions:Nd:YAG laser lysis is an effective alternative to ramove the fibri-nous membrane and remnant substances on the anterior surface of IOL.Eye Sci-ence1995;11:128-130.

  15. Long-term pathologic follow-up of obsolete design: Choyce Mark VIII anterior chamber intraocular lens.

    Science.gov (United States)

    Ollerton, Andrew; Stagg, Brian C; Leishman, Lisa; Bodnar, Zachary; Werner, Liliana; Mamalis, Nick

    2012-02-01

    We analyzed an enucleated eye that was blind and painful from a 66-year-old patient implanted with a Tennant modification of the Choyce Mark VIII anterior chamber intraocular lens (IOL) as a secondary procedure in 1978. The eye developed glaucoma, with implantation of an Ahmed valve in 2006. Gross and light microscopic analyses showed corneal decompensation and vascularization, peripheral anterior and posterior synechiae, iris thinning, significant changes in the iris pigmented layer, fibrous tissue on the anterior surface of the iris, and Soemmerring ring formation in the periphery of capsular bag remnants. In addition, there was severe attenuation of the nerve fiber layer and extensive cupping of the optic disc. The IOL surface was overall smooth and regular, without warping of the footplates, and was partially covered by clumps of various cell elements, including giant cells intermixed with pigment. This study represents the longest clinicopathologic correlation report on this IOL. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Simultaneous reconstruction of anterior cruciate ligament and posterior cruciate ligament by using allogeneic patellar tendon under arthroscopy

    Institute of Scientific and Technical Information of China (English)

    ZHOU Li-ping; ZHEN Min-qing; XU Zhong-he

    2005-01-01

    Objective: To evaluate operative effects of a new method to reconstruct anterior crucial ligament (ACL) and posterior crucial ligament (PCL) simultaneously by using patellar tendon under arthroscopy.Methods: From November 1999 to November 2003,the injured ACL and PCL of 11 patients were fixated with compressed screws and reconstructed under arthroscopy with the bone-patellar tendon-bone treated with deep hypothermia and T radiation. At the same time, 2 patients were treated with medial collateral ligament (MCL)reconstruction, 3 with lateral collateral ligament (LCL)reconstruction, 1 with meniscus suture and 4 with whole or partial resection.Results: All patients were followed up for 12-26months (average 16.5 months ). The Lysholm score method was employed to evaluate the knee function. The average preoperative score was 45.3 and the postoperative score was 86.4. Anterior drawer test (ADT) was positive in 11 knees preoperatively and feeble positive in one knee postoperatively. Lachman test was positive in 11 knees preoperatively and in one postoperatively, and feebly positive in two postoperatively. Posterior drawer test was positive in 11 knees preoperatively and feebly positive in 2postoperatively. There were 2 knees with tolerable pain and 2 with knee flexion of 5°-20°.Conclusions: As for simultaneous reconstruction of ACL and PCL under arthroscopy, ailogeneic bone-patellar tendon-bone can not only avoid injury and complication caused by autografting, but also help rehabilitation of the knee function.

  17. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes), t

  18. Altered multiaxial mechanical properties of the porcine anterior lens capsule cultured in high glucose.

    Science.gov (United States)

    Pedrigi, R M; Staff, E; David, G; Glenn, S; Humphrey, J D

    2007-02-01

    Hyperglycemia can alter the mechanical properties of tissues through the formation of advanced glycation endproducts in matrix proteins that have long half-lives. We used a custom experimental system and subdomain finite element method to quantify alterations in the regional multiaxial mechanical properties of porcine lens capsules that were cultured for 8 or 14 weeks in high glucose versus control media. Findings revealed that high glucose significantly stiffened the capsules in both the circumferential and the meridional directions, but it did not affect the known regional variations in anisotropy. Such information could be important in the design of both improved clinical procedures and intraocular implants for diabetic patients.

  19. Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length

    Directory of Open Access Journals (Sweden)

    Mohammad Miraftab

    2014-01-01

    Full Text Available Purpose: To compare the accuracy of  Sanders-Retzlaff-Kraff II (SRK II and 3 rd and 4 th generation intraocular lens (IOL formulas and to compare the effect of different anterior chamber depths among the IOL formulas in cataract patients with normal axial length (AL; 22.0-24.5 millimeters, mm. Materials and Methods: A retrospective chart review was performed of patients with normal AL who underwent cataract surgery. The SRK II and 3 rd generation IOL formulas (Hoffer Q, SRK T, Holladay 1 were compared to the 4 th generation Haigis formula. For analysis, preoperative anterior chamber depth (ACD was divided into three subgroups: ≤3, 3-3.5, and ≥ 3.5 mm. The mean error (ME and mean absolute error (MAE of each formula was compared for each subgroup against the total. The difference between the ME and MAE of the formulas were compared for each ACD subgroup. P 0.05, all comparisons. Conclusion: The SRK II formula can predict refraction in patients with normal AL and ACD less than 3 mm with less error and is preferred over other formulas. The Haigis formula is the preferred choice in patients with a normal AL and ACD longer than 3.5 mm. The prediction accuracy of Hoffer Q, SRK T, and Holladay 1 is comparable in normal AL.

  20. Pupil-occluding organized hyphema anterior to the intraocular lens treated by neodymium: yttrium-aluminum-garnet laser: a case report

    Science.gov (United States)

    Kim, Moosang; Lee, Seung-Jun; Han, Sang Beom; Yang, Hee Kyung; Hyon, Joon Young

    2016-01-01

    We report, to our best knowledge, the first case of treatment of pupil-occluding postoperative organized hyphema anterior to the intraocular lens (IOL) using neodymium: yttrium-aluminum-garnet (Nd:YAG) laser. A 78-year-old Asian female underwent uneventful cataract operation. She had been taking aspirin, which she discontinued 1 week before surgery. Iris prolapse occurred at the end of the surgery, which led to intracameral bleeding. Two weeks later, her best-corrected visual acuity was hand motion. Although hyphema had decreased, pupil-occluding organized hematoma had formed anterior to the IOL. The blood clot anterior to the IOL was removed using Nd:YAG laser. One week later, although the hematoma anterior to the IOL resolved, endocapsular hematoma was observed, which was dispersed with Nd:YAG laser posterior capsulotomy. Two weeks later, her best-corrected visual acuity improved to 20/60. There was no complication associated with Nd:YAG laser. In conclusion, pupil-occluding organized hyphema anterior to the IOL can occur as a complication of cataract surgery, in which Nd:YAG laser can be a useful treatment option. PMID:27462181

  1. 关节镜下自体腘绳肌和异体胫前肌单束重建前交叉韧带的1年随访比较%Autologous hamstring grafts versus allogeneic anterior tibial muscle tendon grafts for arthroscopic reconstruction of single-bundle anterior cruciate ligament: A one-year follow-up

    Institute of Scientific and Technical Information of China (English)

    王洪; Dhakal Rabi Mohan; 孟春庆; 段德宇; 杨述华; 杜靖远; 唐欣; 李立群; 方青; 汤明

    2011-01-01

    BACKGROUND: Due to artificial ligament has chronic fatigue, mere and mere people use a lie graft for the reconstruction of anterior and the posterior cruciate ligament injury.OBJECTP/E: To compare the curath/e effect aftei aithroscopic reconstruction of single-bundle ante lie t cruciate ligament using autclogous hamstring grafts and allogeneic anterior tibial muscle tendon grafts.METHODS: Cases of anterior cruciate ligament reconstruction which using single-bundle autologous hamstring grafts and allogeneic anterior tibia I muscle tend on grafts under arthrosco pic with 1 year follow up were collected. Totalry 23 cases were used autologous hamstring grafts for anterior cruciate ligament reconstruction, and 13 cases were used anterior tibial muscle tendon allograftfor anterior cruciate ligament reconstruction. The fixation of each reconstructed anterior cruciate Igamentwas done by femoral En do Button and tibial biodegradable interference screw. Using a brace to fix the troubled knee and having the physical training of the troubled knee lately and progress K/ely.RESULTS AND CONCLUSION; All the 43 cases were followed up for sk months after reconstruction. Lysholm score of the autologous tendon group was lower than that of the allogeneic tendon group 0.05). There was no significant difference between the two groups of Lysholm score after six months posto pe ratn/ery. Lysholmscore of the two groups after 6 months and a year construction postoperative showed significant difference as compared with preoperation (P < 005). There was significant difference of the Lysholm score after reconstruction in six months follow up and in one year follow up showing a statistic significance (f < 0.05). The curative effect of anterior cruciate ligament reconstruction using autologous hamstring grafts and allogeneic anterior tibial muscle tendon grafts is equally.%背景:由于人工韧带存在慢性疲劳,越来越多的人采用异体肌腱重建前后交叉韧带损伤.目的:比较

  2. Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure

    Science.gov (United States)

    El-Deeb, Mohamed W. A.

    2016-01-01

    Purpose. To assess intraocular pressure (IOP), lens vaulting, and anterior chamber (AC) angle width, following V4C implantable Collamer lens (ICL) procedure for myopic refractive error. Methods. A prospective case series that enrolled 54 eyes of 27 patients that were evaluated before and after V4C phakic posterior chamber Collamer lens implantation for correction of myopic refractive error. Preoperative measurement of IOP was done using Goldmann applanation tonometer and anterior chamber angle width using both Van Herick slit lamp grading system and Scheimpflug tomography imaging (Oculus Pentacam). Follow-up of the aforementioned variables was at 1, 6, and 18 months postoperatively, together with ICL vault measurements. Results. The mean baseline IOP of 11.69 ± 2.15 showed a statistically significant (P = 0.002) increase after 1 month that remained unchanged at 6 and 18 months postoperatively, with mean value of 16.07 ± 4.12, 16.07 ± 4.10, and 16.07 ± 4.13, respectively. Pentacam AC angle width showed a statistically significant decrease at 1 (P = 0.025), 6 (P = 0.016), and 18 (P = 0.010) months postoperatively, with mean preoperative value of 40.14 ± 5.49 that decreased to 25.28 ± 5.33, 25.46 ± 5.44, and 25.49 ± 5.38, at 1, 6, and 18 months, respectively. Mean ICL vault showed moderate correlation with Pentacam AC angle width at 1 (r = −0.435) and 6 (r = −0.424) months. Conclusion. V4C ICL implantation resulted in decrease in AC angle width and increase in IOP, within acceptable physiological values at all time points. PMID:28053776

  3. Evaluation of Changes in Anterior Segment Configuration by Ultrasound Biomicroscopy after Phacoemulsification and Foldable Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    ilhami Salcan

    2011-08-01

    Full Text Available Purpose: To quantify the configuration changes in anterior segment structures after cataract extraction using ultrasound biomicroscopy (UBM. Material and Method: 33 eyes of 33 patients (21 male, 12 female; mean age: 69.0±8.3 years with senile or presenile cataracts undergoing cataract surgery were prospectively studied. UBM was performed for each patient before and 1 month after surgery. At each UBM examination, axial images of the anterior chamber and radial sections of the angle in four quadrants were obtained. The measurements were performed by using the calipers included in the equipment software and UBM Pro2000® software. Results: After cataract surgery, we determined statistically significant increases in anterior chamber depth and angle parameters (p=0.001. We found that the postoperative increases in anterior chamber depth, angle recess area, angle opening distance 250 and angle opening distance 500 were 1.3, 1.4, 1.7 and 1.5 times, respectively, when compared with the preoperative levels. Decreases in acceleration and increases in y-intercept were determined in 4 quadrants postoperatively by of linear regression analysis of anterior chamber angle and these were also statistically significant (p=0.001. Discussion: UBM gives both qualitative and quantitative valuable information about anterior segment structures. We think that UBM may be a useful tool for evaluation of patients with cataract and occludable and/or narrow angles undergoing cataract surgery for therapeutic purpose. (Turk J Ophthalmol 2011; 41: 200-6

  4. 自体与同种异体肌腱重建前交叉韧带%Autologous and allogeneic tendons for anterior cruciate ligament reconstruction

    Institute of Scientific and Technical Information of China (English)

    亚夏尔•苏来曼; 张克远

    2014-01-01

    BACKGROUND:There is a controversy in the clinical anterior cruciate ligament reconstruction using autologous hamstring tendon or tendon alograft. OBJECTIVE:To compare the clinical results of anterior cruciate ligament reconstruction with tendon alograft and autograft. METHODS: Totaly 123 patients with injured anterior cruciate ligament received anterior cruciate ligament reconstruction and they were divided into two groups: 63 cases in autograft group and 60 cases in alograft group. The postoperative effects were assessed by the Lysholm score and Lachman test. RESULTS AND CONCLUSION: Al the patients were folowed for more than 8 months. After anterior cruciate ligament reconstruction, the stability of the knee joint, Lysholm scores and Lachman test results were al improved significantly in the two groups; while there was no difference between the two groups at the last folow-up (P > 0.05). The clinical outcomes of anterior cruciate ligament reconstruction with alograft and autograft are almost similar; therefore, surgeons should select ideal graft according to the patient’s condition and surgeon’s experience.%背景:前交叉韧带损伤修复采用自体腘绳肌腱还是同种异体肌腱目前在临床上的应用存在争议。目的:分析关节镜下自体肌腱与同种异体肌腱重建前交叉韧带的临床疗效。方法:前交叉韧带断裂重建患者123例,根据移植物的不同将患者分为自体肌腱组63例和异体肌腱组60例。治疗后随访进行Lachman试验、Lysholm评分评估疗效。结果与结论:患者均经过8个月以上随访。两组患者术后膝关节稳定性均较治疗前得到明显好转,两组患者治疗后Lysholm评分、Lachman试验结果均显著好于治疗前,末次随访组间比较差异无显著性意义(P >0.05)。结果说明自体肌腱与同种异体肌腱重建前交叉韧带的疗效相近,医师应根据自身经验和患者情况灵活使用。

  5. Iatrogenic Lens Injuries

    Directory of Open Access Journals (Sweden)

    Ümit Kamış

    2012-12-01

    Full Text Available During intraocular surgery, undesired damages of various etiology may occur in adjacent tissues. One of these tissues is the crystalline lens, which may be traumatized both in anterior segment and posterior segment surgeries, and when damaged, it usually causes marked decrease in visual acuity. The leading causes of iatrogenic lens injuries are intravitreal injection, laser iridotomy, phakic intraocular lens implantation, anterior chamber paracentesis, and vitreoretinal surgery. When crystalline lens damage occurs, its negative effect on visual function may be eliminated by performing cataract surgery intraoperatively or in elective conditions. (Turk J Ophthalmol 2012; 42: Supplement 27-30

  6. [Lens platform].

    Science.gov (United States)

    Łukaszewska-Smyk, Agnieszka; Kałuzny, Józef

    2010-01-01

    The lens platform defines lens structure and lens material. Evolution of lens comprises change in their shape, angulation of haptens and transition of three-piece lens into one-piece lens. The lens fall into two categories: rigid (PMMA) and soft (siliconic, acrylic, colameric). The main lens maaterials are polymers (hydrophilic and hydrophobic). The lens platform has an effect on biocompatibility, bioadhesion, stability of lens in capsule, degree of PCO evolution and sensitiveness to laser damages.

  7. 超声生物显微镜观察弹性开放襻前房型人工晶状体对眼前段结构的影响%The influence of flexible open-loop anterior chamber intraocular lens on the structure of ocular anterior segment

    Institute of Scientific and Technical Information of China (English)

    陈伟蓉; 刘奕志; 陈秀琦; 程冰; 刘玉华

    2001-01-01

    Objective To evaluate the therapeutic effects and safety offlexible open-loop anterior chamber intraocular lens (FOAC-IOL). Methods By ultrasound biomicroscopy, the positions of the haptics of FOAC-IOL in 20 patients (20 eyes) and the relationships of the haptics with iris and anterior chamber angle structures were observed postoperatively to evaluate the impact of these lenses on the structures of ocular anterior segment. Follow-up duration was from 6 to 20 months. Results Among 40 IOL′s haptics, twenty-six haptics were fixed at the recess of the chamber angle ;and other fourteen haptics penetrated the iris and invaded into the ciliary stroma, which caused recurrent uveitis. There was 1 eye with eccentric lens. There were 8 eyes with anterior synechiae of iris, which were related to the haptics of intraocular lens. Conclusions Ultrasound biomicroscopy works well in dynamic observation of the influence of intraocular lens on ocular anterior segment. The haptics of flexible open-loop anterior chamber intraocular lens should be modified.%目的 评价弹性开放襻一体型前房型人工晶状体(anterchamberintraocularlens,AC-IOL)植入术的疗效及其安全性。方法 应用超声生物显微镜观察20例(20只眼)弹性开放襻一体型AC-IOL植入术后患者IOL襻的位置,以及其与虹膜及房角结构的关系,从而评价IOL对眼前段结构的影响。随访时间6~20个月。结果 40个IOL襻中,26个襻固定于房角隐窝;14个襻(8只眼)穿过虹膜侵入至睫状体实质内,并伴有反复发作的葡萄膜炎。术后8只眼虹膜前粘连与IOL襻有关。结论超声生物显微镜检查是动态了解IOL对眼前段结构影响的有效方法。AC-IOL襻的设计有待进一步改进。

  8. 角膜塑形镜对角膜前后表面曲率半径和前房深度的影响%The affect of orthokeratology lens to the anterior and posterior corneal surface and anterior chamber depth

    Institute of Scientific and Technical Information of China (English)

    陈蛟; 肖满意; 王华; 郭颖卓; 何书喜

    2013-01-01

      目的:探讨角膜塑形镜对角膜前后表面曲率半径和前房深度的影响。方法:用Orbscan-Ⅱ角膜地形图,检查17例31眼配戴角膜塑形镜3个月后角膜前后表面曲率半径和前房深度的变化。结果:配戴角膜塑形镜3个月后所有患者屈光度下降,裸眼视力上升(P0.05)。结论:角膜塑形镜主要通过改变角膜前表面的曲率,压平角膜前表面达到矫正近视的目的,对角膜后表面与前房深度无明显影响。%Objective To find out the affect of orthokeratology lens to the anterior and posterior corneal sur-face and anterior chamber depth.Methods 17 patients ,31eyes, after 3 months orthokeratology wearing, corneal topography examination with Orbscan-Ⅱ,record the changes of the anterior and posterior corneal surface radius and anterior chamber depth.Results After 3 months orthokeratology wearing, the refraction diopter decline, uncor-rected visual acuity increased (P0.05).Conclusion Orthokeratology lens mainly affects the shape of the anterior corneal surface , flatten the anteri-or corneal surface, rather than change of the posterior corneal surface radius and anterior chamber depth to achieve the effect of reducing refraction.

  9. Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone Bacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Ricardo Antonio Pereira

    2004-12-01

    Full Text Available OBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05. CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.PURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05, frequencies of

  10. Avaliação da contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular Anterior chamber contamination in phacoemulsification surgery with intraocular lens implant

    Directory of Open Access Journals (Sweden)

    Cesar Nobuo Shiratori

    2002-06-01

    Full Text Available Objetivo: Avaliar a existência de contaminação da câmara anterior durante a facectomia por facoemulsificação com implante de lente intra-ocular. Método: Foi realizado estudo prospectivo, avaliando-se 30 pacientes submetidos a facectomia por facoemulsificação com implante de lente intra-ocular, colhendo-se duas amostras de humor aquoso, uma obtida no início e outra no final da cirurgia. As amostras foram semeadas em meio de cultura para germes aeróbios, anaeróbios e fungos. Resultado: Todas as amostras avaliadas resultaram negativas. Conclusão: A contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular, usando os cuidados necessários, é infreqüente.Purpose: To evaluate the frequency of anterior chamber contamination during phacoemulsification surgery with intraocular lens implant. Method: A prospective study was done with 30 patients submitted to phacoemulsification surgery with intraocular lens implant. Two samples of the aqueous humor were removed from the anterior chamber, one at the beginning and another one at the end of the surgery and were inoculated in culture plates for anaerobic and aerobic bacteria and fungi. Results: Intraocular aspirates yielded negative cultures. Conclusion: The absence of microorganisms in the samples evaluated allowed us to conclude that contamination during the phacoemulsification surgery with lens implant is unusual.

  11. In vivo human crystalline lens topography.

    Science.gov (United States)

    Ortiz, Sergio; Pérez-Merino, Pablo; Gambra, Enrique; de Castro, Alberto; Marcos, Susana

    2012-10-01

    Custom high-resolution high-speed anterior segment spectral domain optical coherence tomography (OCT) was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo. The system was provided with custom algorithms for denoising and segmentation of the images, as well as for fan (scanning) and optical (refraction) distortion correction, to provide fully quantitative images of the anterior and posterior crystalline lens surfaces. The method was tested on an artificial eye with known surfaces geometry and on a human lens in vitro, and demonstrated on three human lenses in vivo. Not correcting for distortion overestimated the anterior lens radius by 25% and the posterior lens radius by more than 65%. In vivo lens surfaces were fitted by biconicoids and Zernike polynomials after distortion correction. The anterior lens radii of curvature ranged from 10.27 to 14.14 mm, and the posterior lens radii of curvature ranged from 6.12 to 7.54 mm. Surface asphericities ranged from -0.04 to -1.96. The lens surfaces were well fitted by quadrics (with variation smaller than 2%, for 5-mm pupils), with low amounts of high order terms. Surface lens astigmatism was significant, with the anterior lens typically showing horizontal astigmatism ([Formula: see text] ranging from -11 to -1 µm) and the posterior lens showing vertical astigmatism ([Formula: see text] ranging from 6 to 10 µm).

  12. 保留晶状体前囊减少硅油并发症的临床观察%Clinical observation on preservation of anterior lens capsule in the reduction of complications associated with silicone oil

    Institute of Scientific and Technical Information of China (English)

    宋宗明; 惠延年; 王琳; 曹小燕; 高前应

    2001-01-01

    Objective To observe the effect of preservation of anterior lens capsule on the incidence of complications associated with silicone oil. Methods Eighty-two patients(82 eyes)accepted trans pars plana vitrectomy combined with lensectomy,30 eyes with preservation of anterior lens capsule (PAC) and 52 eyes with no preservation of anterior capsule(NPAC)were observed.The incidence of complications was analysed to investigate whether PAC could reduce the complications associated with the usage of tamponade of silicone oil. Results The incidence was 50.0% in NPAC group,and 23.3% in PAC group(0.010<P<0.025).There were secondary glaucoma(21.1%),band keratopathy(13.5%)and corneal decompensation(9.6%)in NPAC group,while there was none of them in PAC group. Conclusion Preservation of anterior lens capsule is an effective measure to reduce the complicaltons associated with the tamponade of silicone oil.%目的观察保留晶状体前囊对硅油眼并发症的影响。方法 82只眼行玻璃体切割联合晶状体切除手术,其中30只眼术中保留完整晶状体前囊,52只眼未保留前囊,随访观察硅油并发症的发生情况。结果有前囊组硅油并发症的发生率为23.3%、无前囊组为50.0%(0.010<P<0.025)。后者主要有继发性青光眼(21.2%)、角膜带状变性(13.5%)和角膜内皮失代偿(9.6%)。结论保留晶状体前囊可以减少硅油眼并发症的发生

  13. 类风湿关节炎患者人工晶状体植入后前房反应%Anterior chamber inflammation after intraocular lens implantation in patients with rheumatoid arthritis

    Institute of Scientific and Technical Information of China (English)

    马伟华; 赵俊丽

    2013-01-01

    目的 观察类风湿关节炎患者白内障囊外摘出人工晶状体植入术(ECCE+ IOL)与超声乳化吸出人工晶状体植入术(Phaco+ IOL),比较其术后前房反应程度;探讨类风湿因子滴度与术后前房反应的关系.方法 类风湿关节炎患者11例(11眼)行ECCE+ IOL术;10例(12眼)行Phaco+ IOL术.术后复诊随访.结果 除1例(1眼)视神经萎缩,1例(1眼)老年黄斑变性外,其它均获得了0.6或以上的矫正视力,3个月后前房炎症消失,无手术并发症;行Phaco+ IOL术后前房反应较ECCE +IOL术后前房反应轻,术后3d两组间的差异具有统计学意义(mann-whitney u test分析P=0.0258).术后3d、1个月不同前房反应组的类风湿因子之间差异无统计学意义(mann-whitney utest分析,P>0.05).结论 类风湿性关节炎患者Phaco+ IOL术后前房反应较ECCE +IOL术后前房反应轻;术后前房反应的程度与术前类风湿因子滴度无关.%Objective To compare the postoperative anterior chamber inflammation between extracapsular cataract extraction with intraocular lens implantation (ECCE + IOL) and phacoemulsification with intraocular lens implantation (Phaco + IOL) on patients with rheumatoid arthritis,and to investigate the relation of rheumatoid factor and inflammation in anterior chamber.Methods The medical records of 23 eyes of 21patients with rheumatoid arthritis were reviewed,who underwent cataract extraction with intraocular lens implantation.ECCE + IOL was performed in 11 cases (11 eyes),and Phaco + IOL was performed in 10 cases (12 eyes).Patients had been followed up for 3 months.Results All the eyes,except for one case of optic atrophy and one case of age-related macular degeneration,acquired visual acuity of 0.6 or better.Inflammation in anterior chamber disappeared 3 months after surgery,and left no operative complication in any of the eyes.The inflammation in anterior chamber on patients who performed Phaco + IOL was lighter than patients who performed

  14. Clinical observation on the efficacy of preserving anterior lens capsule in lensectomy combined with vitrectomy surgery%保留晶状体前囊的玻璃体晶状体切除术临床观察

    Institute of Scientific and Technical Information of China (English)

    史志洁; 吕晓贝

    2016-01-01

    Objective To observe the efficacy of preserving complete anterior lens capsule in lensectomy combined with vitrectomy.Methods The records of 68 eyes of 68 patients with vitreoretinal disease complicated with opaque lens were analyzed.The conventional three-channel pars plana vitrectomy and lensectomy were performed on all patients.The cental part of posterior capsule,nucleus and cortex of lens were resected completely by cutting head.The complete anterior capsule and peripheral part of the posterior capsule of lens were retained.Vitrectomy and retinal reattachment operations were performed after above operation.Results The patients were followed up for 12 months.The retina reattached in 66 cases of 68 patients (97.06%).Two cases(2.94%) occurred recurrent retinal detachment,which were reattached after silicone oil tamponade.The posterior chamber IOL implantation were performed at 6 months after vitrectomy and lensectomy surgery.Conclusion Preserving complete anterior lens capsule in lensectomy and vitrectomy surgery is a safe and effective treatment,which can shorten operative time and reduce complication.%目的 观察保留完整晶状体前囊的方法在晶状体切除联合玻璃体切除手术的临床效果.方法 对伴有晶状体浑浊的玻璃体视网膜疾病68例(68眼)进行观察分析.做常规平坦部三通道玻璃体切除及晶状体切除术,玻切头从后方切除中央部晶状体后囊、晶状体核及皮质,保留周边部晶状体后囊及完整的晶状体前囊,然后进行玻璃体切除、视网膜复位等手术操作.结果 术后随访12个月,本组68例中66例(97.06%)视网膜复位良好,视网膜脱离未复发;2例(2.94%)视网膜脱离复发经再次硅油填充后视网膜复位.术后6个月后行二期人工晶状体植入术.结论 保留完整晶状体前囊的晶状体切除联合玻璃体切除术治疗伴晶状体浑浊的玻璃体视网膜疾病是一种缩短手术时间和减少并发症的安全而有效的手术方式.

  15. Analysis of therapeutic effect of rehabilitation treatment improving function of knee joint following reconstruction anterior crucial ligament with allogenic achilles tendon under arthroscopy%跟腱重建前十字韧带术后康复治疗恢复膝关节功能的疗效分析

    Institute of Scientific and Technical Information of China (English)

    常青; 黄迅悟; 张晓鸥; 郑光新

    2002-01-01

    Objective Combining the reconstruction of anterior crucial ligament(ACL) with functional rehabilitation,we recover the injured knee as possible as can.Methods 38 patients received ACL reconstruction with allogenci Achilles tendon under arthroscopy.We reconstructed the injured ACL and the injured medial crucial ligament(MCL) by utilization of length of achiles tendon.Then we carried out different rehabilitations in accordance with special needs of the patients.Results The follow up was performed for more than 7 months in 34 cases.Lysholm method was used to evaluate patients' function before and after operation.Results showed average score was 53.8 preoperatively, and 84.2 postoperatively,the good rate was 84.4% .In the objective examination,anterior drawer test(ADT),31 cases were positive preoperatively,1 was positive postoperatively;lachman test:34 were positive preoperatively,1 was positive postoperatively;4 were weak positive postoperatively.There were 3 cases with pain of knee joints and 4 cases with limitation of activity of knee joints(5~ 20 degree) postopratively.Conclusion Combination of reconsgruction of ACL with allogenic achilles tendon and the functional rehabilitation can gain remarkable curative effect.

  16. Pentacam of the anterior segment after implantation of iris-fixated lens%应用Pentacam三维眼前段分析仪对虹膜夹型人工晶状体植入术后的研究

    Institute of Scientific and Technical Information of China (English)

    汤欣; 邢晓杰

    2008-01-01

    目的 应用Pentacam术后追踪测量虹膜夹型有晶状体眼人工晶状体(PIOL)中央和周边部与角膜内皮和自然晶体之间的距离,倾斜度、偏心值以及前房深度的变化,评价其在前房的位置.方法 收集自2006年1月以来接受虹膜夹型人晶状体植入术的22例33只眼.术后6个月全部患者行Pentacam检查,测量VRSM50和VRSM60两组不同类型虹膜夹型PIOL中央和周边部与角膜内皮和自然晶体之间的距离,并测量术后1d、1、3及6个月人工晶状体的偏心量、倾斜度及前房深度值.结果 角膜内皮至PIOL光学部前表面距离为(1.94±0.36)mm.PIOL后表面与自然晶状体间的距离为(0.76±0.12)mm.分别比较各组在不同时期的平均偏心量与平均倾斜度,差异无统计学意义(P>0.05).在术后1d、1、3及6个月,比较2组的平均偏心量与平均倾斜度,差异无统计学意义(P>0.05).结论 Pentacam三维眼前段分析仪为PIOL植入术后提供高质量的Scheimpflug摄像,可以为有晶状体眼前房型人工晶状体提供精确的眼内定位,在这一方面具有重要的临床应用价值.%Objective To evaluate intraocular dimensions of the anterior segment and examine decentration,tilt and anterior chamber depth (ACD)of myopic phakic eyes after implantation of iris-fixated lenses.Methods Thirty-three myopic eyes that received a iris-fixated phakic intraocular lens (PIOL) were assessed.The eyes were randomized into VRSM50 and VRSM60 2 groups based on PIOL type.Distances between the cornea and the PIOL-optic edge and between the PIOL optic and the crystalline lens were evaluated using Scheimpflug photography 6 months postoperatively.The degree of IOL decentration, tilt and ACD was measured 1 day and 1,3and 6 months after surgery.Results The average postoperative distance between the central corneal endothelium and the anterior surface of the PIOL wasl.94±0.36 mm.The distance between the crystalline lens and posterior surface of the PIOL

  17. 人工晶状体植入术后房角与眼压变化之间的相关性研究%Correlation of the anterior chamber angle and intraocular pressure changes after intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    刘玉青; 叶存喜; 刘玉霞; 戴冬姝; 冀向宁; 王静娴; 邹媛媛; 李坤; 王志学; 侯四清

    2011-01-01

    目的 研究人工晶状体植入术后前房角宽度及眼压变化情况之间的相关性.方法 随机选取120例(137只眼)老年性白内障患者,于表麻下行透明角膜切口超声乳化白内障摘除人工晶状体植入术,保留手术过程顺利、后囊膜完整、人工晶状体植入囊袋中的病例作为研究对象.术前用超声生物显微镜(UBM)测量房角相关参数:房角开放距离(AOD500)、小梁虹膜夹角(TIA)、前房深度(ACD);用Goldmann眼压计测量眼压.分别于术后2周、1个月、3个月再用UBM及Goldmann眼压计复查如上参数;术前以前房角镜观察并记录房角形态并于术后1个月复查房角形态.结果 术前所测量的眼压与正常眼前节数据有显著性差异;术前所测量的ACD、AOD、TIA、眼压分别与术后2周、1个月、3个月复查数据进行多样本均数间的多重比较,均为P<0.05,均有显著性差异;术后2周、1个月、3个月时,AOD及眼压改变的量之间存在负相关;TIA夹角及眼压改变的量之间存在负相关.结论 (1)研究对象的ACD、AOD、TIA与正常眼前节相关数据比较,无显著性差异;但是,眼压较正常值稍高,提示部分患者有发生闭角型青光眼的潜在趋势.(2)超声乳化白内障摘除人工晶状体植入术后,前房深度及房角宽度显著增大,眼压显著降低,避免或减少了闭角型青光眼的发生机会.(3)AOD、TIA这2个变量与眼压这个变量间呈负相关.提示在老年人群中,AOD、TIA是影响眼压的重要因素.%Objective To study the correlation of anterior chamber angle and intraocular pressure changes after intraocular lens implantation. Methods 120 patients with cataract were randomly selected, anesthesized, and underwent phacoemulsification cataract extraction and intraocular lens implantation. The surgery went smoothly, the posterior capsule was intact, and intraocular lens was implanted in the capsular bag. Preoperative and postoperative measurement

  18. 可植入胶原聚合透镜植入术后早期眼前段观察%Observation of anterior segment after implantation of implantable collamer lens in early stage

    Institute of Scientific and Technical Information of China (English)

    栗静; 刘磊; 李新宇; 王虎杰

    2014-01-01

    Objective To observe the anterior segment after implantation of implantable collamer lens (ICL) in early stage.Methods 65 eyes of 37 patients with high myopia who accepted ICL implantation were enrolled in this study.Anterior chamber volume (ACV),anterior chamber depth (ACD),iridocorneal angle,intraocular pressure (IOP) and endothelial cell density were measured at pre-operation,1 month and 6 months after surgery,and measurements were analyzed by statistical analysis.Results After surgeries,the ACD,iridocorneal angles and ACV decreased statistically significantly,and there were no statistical differences between measurements of 1 month and 6 months after surgery; the IOP measured at postoperative 1 month was lower than before and achieved stable state during postoperative 6 months; The endothelial cell density decreased about 4.75% and 6.87% respectively at postoperative 1 month and 6 months (P < 0.05) ; The mean central vault were (412.61 ± 192.94) μm and (365.69 ± 179.75) μm respectively at postoperative 1 month and 6 months,the ICLs had no contact with lens.Conclusion In the early period after implantation of ICL,the anterior segment morphology changed significantly,but these indexes were stable and no closure of iridocorneal angle or increasing of IOP were observed in the follow-up 6 months,therefore,long time follow-up is still required.%目的 观察有晶状体眼可植入胶原聚合透镜(ICL)植入术后早期的眼前段形态.方法 随机选取接受ICL植入术的高度近视37例(65只眼),测量患者术前、术后1个月和6个月的前房深度、前房角、前房容积、眼压和角膜内皮细胞密度,并对测量结果进行统计学分析.结果 术后前房深度、前房角和前房容积均较术前显著减小,术后1个月和术后6个月相比差异无统计学意义.术后1个月时眼压较术前稍有降低,术后6个月时恢复至术前水平;术后1个月和6个月患眼角膜内皮细胞密度较术前分别降低4

  19. In vivo human crystalline lens topography

    OpenAIRE

    Ortiz, Sergio; Pérez Merino, Pablo; Gambra, Enrique; Castro, Alberto; Marcos, Susana

    2012-01-01

    Custom high-resolution high-speed anterior segment spectral domain optical coherence tomography (OCT) was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo. The system was provided with custom algorithms for denoising and segmentation of the images, as well as for fan (scanning) and optical (refraction) distortion correction, to provide fully quantitative images of the anterior and posterior crystalline lens surfaces. The method was tested on an artificial eye ...

  20. 同种异体髌腱移植重建膝关节前交叉韧带的手术配合%Operation cooperation for rebuilding joint anterior cruciate ligament by allogeneic patellar tendon transplantation

    Institute of Scientific and Technical Information of China (English)

    万效梅; 刘春英; 孙丽

    2005-01-01

    @@ 同种异体肌腱移植修复肌腱缺损已在临床广泛开展,应用异体骨-髌腱-骨(bone-patellar tendon-bone,BPTB)修复膝关节前交叉韧带(anterior cruciate ligament,ACL)在国内外均获得成功[1],此种术式不仅减少了自体取材造成的再损伤及引起的并发症,而且简化了手术方法,缩短了手术时间.2003年,我院在关节镜下实行同种异体BPTB移植重建ACL 11例,效果满意,现将手术护理体会总结如下.

  1. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  2. Pupillary block glaucoma following implantation of a posterior chamber pseudophakos in the anterior chamber.

    Directory of Open Access Journals (Sweden)

    Mandal Anil

    2002-01-01

    Full Text Available Pupillary block glaucoma is a common complication of cataract surgery, especially following anterior chamber intraocular lens implantation. We report a case of pupillary block glaucoma with a posterior chamber IOL that was implanted in the anterior chamber following a complicated extracapsular cataract extraction. The case was successfully managed by explantation of the posterior chamber lens, anterior vitrectomy, peripheral iridectomy and secondary anterior chamber intraocular lens implantation. The intraocular pressure was controlled with a single topical antiglaucoma medication.

  3. Quantitative changes of anterior segment before and after implantable collamer lens implantation for high myopia with Pentacam anterior segment system%Pentacam评估高度近视有晶状体眼人工晶状体植入术前后眼前节形态的改变

    Institute of Scientific and Technical Information of China (English)

    周远香

    2015-01-01

    目的:通过眼前节全景分析仪( Pentacam)量化分析高度近视患者行ICL植入术手术前后眼前节形态的改变,评估手术的安全性、有效性。  方法:收集我院2011-09/2013-02高度近视眼行ICL植入手术的患者21例39眼,术后随访6~12mo。通过Pentacam分别测量术前;术后1wk;1,6mo的中央前房深度( ACD)、前房角度(ACA)、前房容积(ACV);记录术后1wk;1,6mo的ICL拱高(ICL-vault);记录术前裸眼视力(pre-UCVA)、最佳矫正视力( BCVA)、术后裸眼视力( post-UCVA)以及眼压值。使用SPSS18.0统计软件分析各项指标,术前、术后的资料均采用配对t检验进行统计学分析。  结果:术前;术后1wk;1,6mo 的ACD分别是3.27±0.22,3.02±0.33,2.98±0.31,2.98±0.32mm, ACA分别是(40.39±5.40)°,(26.70±4.47)°,(26.96±4.48)°,(26.95±4.45)°, ACV分别是207.74±25.43,122.87±17.58,128.05±17.84, ;128.64±17.50mm 3。术后1wk;1,6mo的拱高分别是0.49±0.13,0.46±0.13,0.46±0.14mm。术前与术后3个不同时段的ACD,ACA,ACV的值相比,其均存在统计学差异( P  结论:通过眼前节全景分析仪( Pentacam)分析发现ICL术后前房变浅,房角变窄,前房容积变小,但人工晶状体与透明晶状体之间仍拥有安全的间隙,ICL植入术治疗高度近视眼安全、有效,但远期疗效有待进一步观察。%•AlM: To analyze the quantitative changes of anterior segment by Pentacam anterior segment system and to evaluate the safety and effectiveness after implantable collamer lens ( lCL) implantation for high myopia. •METHODS:Twenty- one patients with 39 eyes were implanted lCL in our hospital from September 2011 to February 2013. The follow-up was 6 ~ 12mo. Central anterior chamber depth ( ACD ) , anterior chamber angle ( ACA) , anterior chamber volume ( ACV) were measured by Pentacam preoperatively, 1wk, 1 and 6mo postoperatively. The distance between crystal lens and lOL ( lCL- vault ) were measured at

  4. 玻璃体切除术后无晶状体眼前房灌注下人工晶状体悬吊术%Intraocular lens ciliary sulcus suspension in aphakic vitrectomized eyes under anterior chamber perfusion

    Institute of Scientific and Technical Information of China (English)

    杨艳; 梁军; 张伟

    2015-01-01

    目的:观察25 G前房灌注下经3.0 mm切口二期睫状沟悬吊折叠型人工晶状体(IOL)治疗晶状体玻璃体切除术后无晶状体眼的临床效果。方法回顾性非对照病例分析。我院2012年1月至2013年12月因严重玻璃体视网膜病变曾行晶状体玻璃体切除术的无晶状体眼31例(31眼),术前裸眼视力为数指~0.12,最佳矫正视力0.15~0.8。玻璃体术后>6个月。二期于25 G前房灌注下经3 mm角膜缘切口植入IOL缝线固定于睫状沟。术后随访3~6个月,观察视力、眼压、角膜内皮细胞计数、IOL位置和并发症发生情况。统计学方法为配对t检验。结果术后3~6个月,裸眼视力为0.1~0.8,较术前提高(P0.01)。术后3个月角膜内皮细胞计数平均(1789±321)个/ mm2,与术前的(1837±289)个/mm2比较,差异无统计学意义(P>0.01)。29眼(93.55)IOL位置居中,另2眼(6.45%)中1眼轻度偏中心,1眼轻度倾斜。1眼术后轻度玻璃体积血。结论在微创25 G前房灌注下,经3.0 mm切口二期睫状沟悬吊折叠型IOL治疗晶玻切术后无晶状体眼,创伤小、眼压维持稳定。%Objective To evaluate the clinical efficacy of suture fixation to ciliary sulcus of a foldable intraocular lens ( IOL ) with the 25 G anterior chamber perfusion in eyes that had pars plana vitrectomy combined with lensectomy. Methods This is a retrospective non-comparative study. The medical data of 31 eyes of 31 patients who had vitrectomy combined with lensectomy surgery for severe vitreoretin opathy from Jan, 2012 to Dec, 2013 were reviewed. The underlying vitreoretinal diseases were complicated ocular trauma ( n = 16 ) , proliferative vitreoretinopathy ( n = 8 ) , proliferative diabetic retinopathy (n= 4), and lens dislocation in vitreous cavity (n=3). The uncorrected visual acuity (VA) of the 31 eyes was from LogMar 6. 64 to LogMar 3. 06 and the best corrected visual acuity ( BCVA) was from LogMar 2. 74 to LogMar 0. 097. In addition, the preoperative

  5. Lenstar LS900与IOLMaster测量眼前节生物参数及人工晶状体度数的比较%Comparison of anterior segment biometry and intraocular lens power measured by Lenstar LS900 and IOLMaster

    Institute of Scientific and Technical Information of China (English)

    叶向彧; 纪建丽; 张广斌; 王乐; 毛益辉; 何雪洪

    2011-01-01

    目的 精确的眼生物测量对人工晶状体(intraocular lens,IOL)度数计算至关重要,尤其是眼轴及角膜曲率的测量.本研究将对比新一代光学低相干反射生物测量仪Lenstar LS900 (Haag-Streit)与IOLMaster对眼前节参数及IOL测算的差异.方法 应用Lenstar LS900和IOLMaster分别对30例(60眼)老年性白内障患者进行眼轴长度、前房深度、角膜曲率和散光轴方面的测量比较;分别利用2种设备计算IOL度数,均选用SRK/T计算公式和SA60AT(Alcon)IOL,在确定同一度数的前提下比较目标屈光度的差异.结果 Lenstar LS900和IOLMaster测量眼轴长度、前房深度、平均角膜曲率、陡峭轴角膜曲率之间差异均无统计学意义(均为P>0.05),且均具有良好的相关性(相关系数分别为0.999、0.955、0.936、0.845),而两种设备测得陡峭轴之间相关欠佳(r =0.579).Lenstar LS900和IOLMaster所获得的术后目标屈光度值分别为(-0.02±0.17)D和(-0.07±0.23)D,差异无统计学意义(P>0.05).Bland-Altman分析显示,2种设备获得的目标屈光值具有良好的一致性.结论 Lenstar LS900和IOLMaster两种设备测量眼前节参数及IOL度数具有良好的一致性.同时,Lenstar LS900还可以快速、准确的为白内障患者和屈光医师提供更多的眼生物参数.%Objective To compare the difference of anterior segment biometry and intraocular lens (IOL) power measured by a new noncontact optical biometer Lenstar LS9O0 (Haag-Streit) using optical low-coherence reflectometry and IOLMaster. Methods Biometry measurements in 60 eyes of 30 patients scheduled for cataract surgery by the same examiner with Lenstar LS900 and IOLMaster, the axial length (AL) .anterior chamber depth (ACD) and keratometric (K) were compared,IOL power for AcrySof SA60AT( Alcon) measure by two devices using SRK/T formulas was calculated, and the difference of targeted diopter under same IOL power was compared. Results There was no statistical

  6. Cervicoplastia anterior Anterior cervicoplasty

    Directory of Open Access Journals (Sweden)

    Lucas Gomes Patrocínio

    2004-10-01

    Full Text Available Muitos pacientes buscam correção estética da frouxidão da pele do pescoço, depósito de gordura na região submentoneana ou bandas de platisma. Em grande parte dos casos a ação medial, via cervicoplastia anterior é necessária. OBJETIVO: Demonstrar a casuística e avaliar os resultados e complicações com a técnica de cervicoplastia anterior no Serviço de Otorrinolaringologia da Universidade Federal de Uberlândia. FORMA DE ESTUDO: Relato de série. PACIENTES E MÉTODOS: Quarenta e dois pacientes, entre 39 e 65 anos de idade, sendo 40 (95,2% do sexo feminino e 2 (4,8% do masculino, foram submetidos a cervicoplastia anterior. Retrospectivamente foram avaliados resultados e complicações. RESULTADOS: Destes, 34 apresentaram resultados satisfatórios, 4 apresentaram déficit estético notado somente pelo cirurgião, 3 apresentaram déficit estético notado somente pelo paciente e 1 apresentou déficit estético necessitando cirurgia revisional. Ao estudo fotográfico, todos os pacientes apresentaram melhora do perfil cervical, redução das bandas de platisma e da frouxidão da pele, estabilização da musculatura cervical e acentuação do ângulo cervicomental, em graus variados. Houve complicação em 2 casos (discreto serohematoma e cicatriz um pouco alargada. CONCLUSÃO: A cervicoplastia, associada ou não à tração lateral pela ritidoplastia, é uma técnica que produz resultados satisfatórios na grande maioria dos casos.Many patients look for aesthetic correction of the laxity of neck skin, submandibular fat deposit or platisma bands. In a large part of the cases, medial action, through anterior cervicoplasty is necessary. AIM: To demonstrate the casuistic and to evaluate the results and complications with anterior cervicoplasty technique in the Otorhinolaryngology Service of the Federal University of Uberlândia. STUDY DESIGN: Serie report. PATIENTS AND METHODS: Forty-two patients, between 39 and 65 years of age, being 40 (95

  7. Contact lens wear is intrinsically inflammatory.

    Science.gov (United States)

    Efron, Nathan

    2017-01-01

    Eye-care practitioners typically associate ocular inflammation during contact lens wear with serious complications such as microbial keratitis; however, more subtle mechanisms may be at play. This paper tests the notion that contact lens wear is intrinsically inflammatory by exploring whether uncomplicated contact lens wear meets the classical, clinical definition of inflammation - rubor (redness), calor (heat), tumor (swelling), dolor (pain) and functio laesa (loss of function) - as well as the contemporary, sub-clinical definition of inflammation (cellular and biochemical reactions). It is demonstrated that all of these clinical and sub-clinical criteria are met with hydrogel lens wear and most are met with silicone hydrogel lens wear, indicating that uncomplicated contact lens wear is intrinsically inflammatory. Consideration of both traditional and contemporary thinking about the role of inflammation in the human body leads to the perhaps surprising conclusion that the chronic, low grade, sub-clinical inflammatory status of the anterior eye during contact lens wear, which may be termed 'para-inflammation', is a positive, protective phenomenon, whereby up-regulation of the immune system, in a non-damaging way, maintains the eye in a state of 'heightened alert', ready to ward off any extrinsic noxious challenge. Characterisation of this inflammatory status may lead to the development of lens engineering or pharmacological strategies to modulate contact lens-induced inflammation, so as to render lens wear more safe and comfortable. © 2016 Optometry Australia.

  8. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil......Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...... of probabilistic functionalism, and concerns the environment and the mind, and adaptation by the latter to the former. This entry is about the lens model, and probabilistic functionalism more broadly. Focus will mostly be on firms and their employees, but, to fully appreciate the scope, we have to keep in mind...

  9. The effect of lens parameters on the development of the primary angle-closure glaucoma

    Institute of Scientific and Technical Information of China (English)

    Zhaohui Feng; Naixue Sun; Aiyi Zhou; Donggang Han; Yun Long; Zhao Wang; Xiaohua Wang

    2007-01-01

    Objective:To investigate the role the lens dimensions played on the pathogenesis of primary angle-closure glaucoma.Methods:38 eyes of 20 patients with primary angle-closure glaucoma (PACG) and 35 eyes of 22 normal individuals without ocular abnormalities were examined. The anatomical parameters of the lens and other structures of the anterior segment were calculated using B ultrasound, computer image processing and ultrasound biomicroscopy (UBM). The parameters were compared between the patients and normal subjects. Correlation analysis was used to determine the relationship between the radii of curvature of the anterior lens surface (RCALS) and the other parameters of the anterior segment. Results:Compared with the normal eyes, the eyes of PACG had thicker lens, steeper curvature of anterior lens surface, decreased depth of the anterior chamber, narrower chamber angle, and more anterior position of the ciliary bodies and lens. All these differences were significant(P < 0.05 or P < 0.01). In the PACG group, the RCALS had significantly negative correlation with the central and peripheral lens thickness (P < 0.01 and P < 0.05 respectively), and had positive correlation with relative lens position, anterior chamber depth (ACD), angle-open distance at 500 um(AOD500), trabecular iris angle(TIA) and trabecular ciliary processes distance(TCPD, P < 0.05 or P < 0.01 ). Conclusion:The occurrence of PACG is relevant to the abnormal anatomical structures of the anterior segment. Among all factors, the lens parameters play an important role in the pathogenesis. Increased lens thickness, relative more anterior position of lens, especially steepened curvature of anterior lens surface are predisposing factors of the pathologic phenomenon in PACG including pupillary blockage, shallow anterior chamber, secondary closure of chamber angle and elevation of intraocular pressure.

  10. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil......Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  11. 关节镜下RetroButton-同种异体肌腱-界面螺钉重建前交叉韧带的近期疗效%SHORT-TERM EFFECTIVENESS OF ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH RetroButton-ALLOGENEIC TENDON-INTERFERENCE SCREW

    Institute of Scientific and Technical Information of China (English)

    陈竞青; 陈百成; 高石军; 李彤; 邵德成

    2011-01-01

    目的 探讨关节镜下应用RetroButton-同种异体肌腱-界面螺钉重建前交叉韧带的手术方法与近期疗效.方法 2009年6月-10月,于关节镜下采用RetroButton-同种异体肌腱-界面螺钉重建23例前交叉韧带损伤.男15例,女8例;年龄19~46岁,平均32.5岁.左膝17例,右膝6例.致伤原因:运动伤13例,交通事故伤8例,坠落伤2例.急性损伤(6周)16例.合并单纯内侧半月板损伤11例,单纯外侧半月板损伤6例,内、外侧半月板同时损伤3例,关节软骨损伤5例.患者均无后交叉韧带、内外侧副韧带或后外侧结构损伤.受伤至手术时间3周~32个月.按照Lysholm评分和国际膝关节评分委员会(IKDC)膝关节评分标准进行主观评估;采用Lachman 试验和KT-1000关节测量仪检查进行客观评估.结果 术后患者切口均Ⅰ期愈合,患膝关节失稳症状明显改善.无高热、感染或明显排斥反应.1例患者术后发生顽固性滑膜炎,关节内反复积液,3周内经关节腔灌洗7次后稳定.患者均获随访,随访时间10~17个月,平均14.7个月.末次随访时IKDC评分、Lyrsholm评分、Lachman试验及KT-1000检测与术前比较,差异均有统计学意义(P<0.05).结论 关节镜下应用RetroButton-同种异体肌腱-界面螺钉重建前交叉韧带手术操作安全、简便,近期疗效满意.%Objective To investigate the method and short-term effectiveness of arthroscopic reconstruction of anterior cruciate ligament (ACL) using RetroButton-allogeneic tendon-interference screw. Methods Between June 2009 and October 2009, 23 patients with ACL rupture were treated by arthroscopic reconstruction with RetroButton-allogeneic tendon-interference screw. There were 15 males and 8 females with an average age of 32.5 years (range, 19-46 years), including 17 left knees and 6 right knees. The injury causes were sport trauma (13 cases), traffic accident (8 cases), and falling injury (2 cases). There were 7 acute cases (< 6 weeks

  12. Application of allogeneic deep-frozen tendon of lower limb with one-end bone block in reconstruction of anterior cruciate ligament%一端带骨块同种异体深冻下肢肌腱重建前交叉韧带的应用

    Institute of Scientific and Technical Information of China (English)

    张义龙; 李宁; 李志怀; 刘建丰; 宋有鑫; 李哲; 刘正蓬

    2011-01-01

    背景:关节镜辅助下重建前交叉韧带的移植物及固定方法的选择存在很多争论,各种固定方法均有其优缺点.目的:评估一端带骨块深冻同种异体肌腱股骨侧嵌入重建膝关节前交叉韧带的效果.方法:纳入2008-01/2009-09 在承德医学院附属医院骨科就诊的15例关节损伤患者(15膝),经关节镜检查证实为前交叉韧带断裂,其中运动损伤7例,交通事故伤6例,摔伤2例.均于关节镜下行一端带骨块的同种异体腱前交叉韧带重建术,记录患者膝关节Lysholm功能评分、KT-1000测量值.结果与结论:对15例患者随访12~24个月,均未发生血管神经损伤、排异、感染等并发症.KT-1000测量值术前双侧膝关节前向松弛度差值为3~5 mm 4例(27%),6~10 mm 9例(60%),>10 mm 2例(13%);末次随访时0~2 mm 12例(80%),3~5 mm 3例(20%).同时,Lysholm膝关节功能评分也由术前的(65.60±10.13)分提高到末次随访时的(90.93±4.06)分(P < 0.05).说明嵌入骨块在重建膝关节前交叉韧带中可增加股骨侧固定的可靠性,治疗效果满意.%BACKGROUND: There are a lot of debates on selections of grafts and ways of fixation methods about ansterior cruciate ligament (ACL) reconstruction. Each fixation has its advantages and disadvantages.OBJECTIVE: To evaluate the effectiveness of allogeneic deep froze tendon of lower limb with one-end bone block in ACL reconstruction.METHODS: Fifteen knees with ACL tear, of which, 7 knees were caused by athletic injury, 6 knees by traffic accident, and 2 knees by falling. ACL tear was verified by arthroscopy, and all the damaged ACL were reconstructed with allograft tendons by inserting technique under arthroscopy. The value of KT-1000 and the Lysholm scores were recorded before operations and at follow-up.RESULTS AND CONCLUSION: All cases were followed up for 12-24 months. No severe complication, such as vascular nerve injury, rejection or infection, occurred. The KT-1000 measurement

  13. 有晶状体眼后房型人工晶状体植入术后前房及前房角的超声活体显微镜观察%Observation on changes of anterior chamber and chamber angle structures after posterior chamber phakic intraocular lens implantation by ultrasound biomicroscopy

    Institute of Scientific and Technical Information of China (English)

    汪晓宇; 沈晔; 杜持新; 李毓敏; 董映

    2009-01-01

    Objective To study the changes of anterior chamber and chamber angle structures after implantable contact lens (ICL) implantation in high myopia by using ultrasound biomicroscopy (UBM).Methods A prospective series case study was conducted on 15 high myopia patients (30 eyes) treated with ICL implant.These patients were followed for one year postoperatively.Intraocular pressure (IOP) was measured by Goldmann applanation tonometer after surgery.All eyes were examined by UBM one year after the surgery.Central anterior chamber depth (ACD), trabecular-iris angle (TIA), the distance between the posterior surface of ICL and the lens and the distance between peripheral surface of ICL and the lens were measured.Nonparametric test was used to compare TIA.One-way ANOVA was used to assess the distance between peripheral surface of ICL and the lens.Repeated Measure ANOVA and Bonferroni test was performed to compare the IOP level before and after surgery.Paired t-test was used to compare ACD.Results Intraocular pressure changed from (13.75±2.27) mm Hg(1 mm Hg=0.133 kPa) preoperatively to (14.27±1.70), (14.70±2.07), (14.07±2.24), (14.00±2.69) and (13.97±2.95) mm Hg at 1 week, 1,3, 6 and 12 months after the surgery, respectively.There was a statistically significant increase of the IOP one month after the surgery, which was normalized completely at 3 months after surgery.The distances between central posterior surface of the cornea to the ICL and the lens were (2.24±0.21 ) and (2.97±0.11) mm, respectively.There was significant difference between these two data (t=20.63, P30°,ICL周边部与晶状体之间的距离在钟表位12:00、3:00、6:00、9:00位差异无统计学意义.ICL后表面与晶状体之间的距离为(0.63±0.16)mm,ICL与晶状体无接触.结论 ICL植入术后ICL位于晶状体前,致使术后中央ACD变浅、部分手术眼前房角宽度变窄.ICL与晶状体无接触,与虹膜后表面接触.

  14. Visual outcome after phacoemulsification with intraocular lens implantation in patients with anterior lenticonus due to Alport syndrome%超声乳化联合IOL植入治疗前圆锥晶状体伴有Alport综合征的视觉效果

    Institute of Scientific and Technical Information of China (English)

    Mohammad Ali Zare; Mohammad Taher Rajabi; Syed Jafar Oskouee; Mohammad Nili

    2006-01-01

    · AIM: We describe visual improvement after phacoemulsification with intraocular lens (IOL) implantation in 7 eyes with anterior lenticonus secondary to Alport syndrome.· METHODS: 7 eyes from 4 patients with Alport syndrome underwent phacoemulsification with IOL implantation due to anterior lenticonus.· RESULTS: All of the patients resumed excellent visual acuity after surgery.· CONCLUSION: We recommend the phacoemulsification with IOL implantation as a safe procedure in anterior lenticonus due to Alport syndrome.%目的:观察超声乳化联合IOL植入治疗7眼前圆锥晶状体伴有Alport综合征患者的手术效果.方法:Alport综合征患者4例,7眼因前圆锥晶状体行超声乳化联合IOL植入手术.结果:所有患者的术后视力均有明显提高.结论:我们认为对于前圆锥晶状体伴有Alport综合征患者采用超声乳化联合IOL植入手术治疗,是一种安全的疗法.

  15. Allogenic bone grafts in post-traumatic juxta-articular defects: Need for allogenic bone banking.

    Science.gov (United States)

    Mishra, Anil Kumar; Vikas, Rohit; Agrawal, H S

    2017-07-01

    Allogenic bone banking provide both structural and granular bone grafts for various orthopaedic, spinal, oncological and dental surgeries. However allogenic bones, presently, are not readily available. This article discusses the clinical applications of the allogenic grafts, the screening criteria and procedure for maintenance of such a bone banking facility. This article demonstrates the effective role of allogenic bone in a case of post-traumatic bone loss situation and discusses the growing need and present situation of bone banking in our country.

  16. Gut microbiota and allogeneic transplantation.

    Science.gov (United States)

    Wang, Weilin; Xu, Shaoyan; Ren, Zhigang; Jiang, Jianwen; Zheng, Shusen

    2015-08-23

    The latest high-throughput sequencing technologies show that there are more than 1000 types of microbiota in the human gut. These microbes are not only important to maintain human health, but also closely related to the occurrence and development of various diseases. With the development of transplantation technologies, allogeneic transplantation has become an effective therapy for a variety of end-stage diseases. However, complications after transplantation still restrict its further development. Post-transplantation complications are closely associated with a host's immune system. There is also an interaction between a person's gut microbiota and immune system. Recently, animal and human studies have shown that gut microbial populations and diversity are altered after allogeneic transplantations, such as liver transplantation (LT), small bowel transplantation (SBT), kidney transplantation (KT) and hematopoietic stem cell transplantation (HTCT). Moreover, when complications, such as infection, rejection and graft versus host disease (GVHD) occur, gut microbial populations and diversity present a significant dysbiosis. Several animal and clinical studies have demonstrated that taking probiotics and prebiotics can effectively regulate gut microbiota and reduce the incidence of complications after transplantation. However, the role of intestinal decontamination in allogeneic transplantation is controversial. This paper reviews gut microbial status after transplantation and its relationship with complications. The role of intervention methods, including antibiotics, probiotics and prebiotics, in complications after transplantation are also discussed. Further research in this new field needs to determine the definite relationship between gut microbial dysbiosis and complications after transplantation. Additionally, further research examining gut microbial intervention methods to ameliorate complications after transplantation is warranted. A better understanding of the

  17. Pars Plana Vitrectomy in Treatment of Lens Injury

    Directory of Open Access Journals (Sweden)

    Remzi Avcı

    2013-01-01

    Full Text Available Lens injury due to traumas may present as loss of capsule integrity, cataract, lens subluxation, or lens luxation. In addition, lens subluxation and lens luxation may occur in pseudophakic patients due to trauma. Clear corneal, scleral or sclero-corneal phacoemulsification surgery, pars plana vitrectomy, pars plana vitrectomy with phaco-fragmentation, or pars plana vitrectomy with removal through corneal incision techniques are used in the treatment of lens injury due to traumas. Intraocular lens can be implanted in the bag, sulcus, or anterior chamber during the surgery. Depending on the circumstances, scleral fixated intraocular lenses or iris-claw lenses may also be preferred. Rehabilitation of such patients is not of a great concern today, with the advanced level of vitreoretinal surgery and cataract surgery techniques and with the current state of technology. (Turk J Ophthalmol 2013; 43: 51-4

  18. Rho GTPase inactivation impairs lens growth and integrity.

    Science.gov (United States)

    Rao, Vasantha; Wawrousek, Eric; Tamm, Ernst R; Zigler, Samuel

    2002-02-01

    To elucidate the significance of Rho GTPase signaling on lens growth and structural integrity, we have selectively inactivated Rho GTPase in the ocular lens. To achieve this tissue-specific inactivation, a transgene encoding the C3-exoenzyme from Clostridium botulinum has been expressed in mice under transcriptional control of the lens-specific alphaA-crystallin promoter. C3-exoenzyme is known to selectively inactivate all Rho GTPase isoforms by ADP-ribosylating an asparagine residue at position 41. Mice expressing the C3-exoenzyme transgene exhibited selective ocular defects, including cataract and microphthalmia. Extralenticular effects included ocular hemorrhage (blood accumulation in the anterior and posterior chambers of the eye) and abnormalities of the iris including focal attachments to lens and cornea (synechiae). C3-transgene expression was found only in the lens and not in the other ocular tissues as determined by RT-PCR analysis. Histologic examination of the eyes of C3 transgenic mice from two independent lines revealed extensive abnormalities of the lens, including defective fiber cell differentiation and elongation, ruptured posterior lens capsule, and thickened anterior lens capsule. Electron microscopic analysis of hemorrhaged C3 eyes showed abnormalities in the posterior hyaloid vessels. Collectively these data reveal the importance of Rho GTPase signaling in regulating lens growth and maintenance of lens transparency.

  19. Image registration reveals central lens thickness minimally increases during accommodation

    Directory of Open Access Journals (Sweden)

    Schachar RA

    2017-09-01

    Full Text Available Ronald A Schachar,1 Majid Mani,2 Ira H Schachar31Department of Physics, University of Texas at Arlington, Arlington, TX, 2California Retina Associates, El Centro, 3Byers Eye Institute of Stanford University, Palo Alto, CA, USAPurpose: To evaluate anterior chamber depth, central crystalline lens thickness and lens curvature during accommodation.Setting: California Retina Associates, El Centro, CA, USA.Design: Healthy volunteer, prospective, clinical research swept-source optical coherence biometric image registration study of accommodation.Methods: Ten subjects (4 females and 6 males with an average age of 22.5 years (range: 20–26 years participated in the study. A 45° beam splitter attached to a Zeiss IOLMaster 700 (Carl Zeiss Meditec Inc., Jena, Germany biometer enabled simultaneous imaging of the cornea, anterior chamber, entire central crystalline lens and fovea in the dilated right eyes of subjects before, and during focus on a target 11 cm from the cornea. Images with superimposable foveal images, obtained before and during accommodation, that met all of the predetermined alignment criteria were selected for comparison. This registration requirement assured that changes in anterior chamber depth and central lens thickness could be accurately and reliably measured. The lens radii of curvatures were measured with a pixel stick circle.Results: Images from only 3 of 10 subjects met the predetermined criteria for registration. Mean anterior chamber depth decreased, −67 µm (range: −0.40 to −110 µm, and mean central lens thickness increased, 117 µm (range: 100–130 µm. The lens surfaces steepened, anterior greater than posterior, while the lens, itself, did not move or shift its position as appeared from the lack of movement of the lens nucleus, during 7.8 diopters of accommodation, (range: 6.6–9.7 diopters.Conclusion: Image registration, with stable invariant references for image correspondence, reveals that during accommodation a

  20. A comparative study of tunnel enlargement after anterior cruciate ligament reconstruction with autologous and allogenic tendons%自体、同种异体肌腱重建前交叉韧带术后骨隧道扩大的对比研究

    Institute of Scientific and Technical Information of China (English)

    白正武; 张明; 贺业腾; 闫新峰

    2012-01-01

    Objective To investigate the changes of bone tunnel and differences of clinical outcomes after anterior cruciate ligament (ACL) reconstruction with hamstring tendons from autografts and allografts. Methods The study involved in 61 patients with ACL injury undergone arthroscopic ACL reconstruction from June 2008 to November 2009.According to ACL graft differences,61 patients were assigned to two groups,ie,Group A ( reconstruction with tendon allografts,n =27 ) and Group B ( reconstruction with tendon autografts,n =34).MRI examination was performed one week and 6-12 months post-operatively to measure the sagittal bone tunnel diameters at the aperture location,at the location of 1cm away from the aperture and at the widest location of tunnel.Taking the bone tunnel diameter at each location one week post-operatively as the measurement criteria,the differences of bone tunnel diameters at each corresponding location were analyzed statistically.Lysholm score was used to evaluate the clinical effects in the two groups. Results Group A and B were followed up for average 8.4 months and 8.5 months,respectively.Pre-operative clinical data of the two groups had no significant difference.MRI follow-up showed that the tunnel diameters at femoral side and tibial side both had different degree of enlargement.Meanwhile,the enlargement degree at the tibial side was larger than that at the femoral side,with no statistical differences of the two groups regarding tunnel enlargement of the three measurement locations at femoral and tibial sides.Joint stability in all patients was good.The two groups showed no significant difference in Lysholm score after operation ( P > 0.05 ). Conclusions Graft difference is a factor for bone tunnel enlargement after ACL surgery.Autologous and allogenic tendons show no difference in their role in bone tunnel enlargement after ACL surgery or correlation with clinical effects.%目的 探讨自体胭绳肌腱、同种异体肌腱对重建前交叉韧带(anterior

  1. Kidney dysfunction after allogeneic stem cell transplantation

    NARCIS (Netherlands)

    Kersting, S.

    2008-01-01

    Allogeneic stem cell transplantation (SCT) is a widely accepted approach for malignant and nonmalignant hematopoietic diseases. Unfortunately complications can occur because of the treatment, leading to treatment-related mortality. We studied kidney dysfunction after allogeneic SCT in 2 cohorts of

  2. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  3. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  4. The effect of postoperative central vault on the anterior chamber after implantation of implantable contact lens V4c%有晶体眼后房型人工晶体 V4c 植入术后拱高对前房结构的影响

    Institute of Scientific and Technical Information of China (English)

    叶进; 袁长明; 王霁雪; 谢汉平

    2015-01-01

    目的:观察有晶体眼后房型人工晶体 V4c 植入术后拱高对前房结构的影响。方法对重庆普瑞眼科医院2014年11月2日至2015年2月5日开展的56眼有晶体眼后房型人工晶体 V4c 植入术进行回顾性研究。术前用房角镜检查房角并记录前房角色素分级,用 Pentacam 测量平均前房角宽度(ACA )、前房容积(ACV )。术后第1、3、6个月复诊时测量中央拱高和平均ACA 以及 ACV ,并记录前房角色素分级。对患者手术后3次复查的拱高与 ACA 减小的量、ACV 减小的量进行相关性分析。结果术后1个月56眼的拱高为250~765μm ,ACA 减小的量为(13.67±1.67)°,ACV 减小量为(94.23±17.02)mm3。术后第3个月55眼的拱高为239~761μm ,ACA 减小的量为(13.70±1.68)°,ACV 减小量为(93.6±17.48)mm3。术后第6个月51眼拱高为246~761μm ,ACA 减小的量为(13.60±1.69)°,ACV 减小量为(94.29±17.80)mm3。未发现色素为Ⅱ级的病例。将3次复查的中央拱高与 ACA 和 ACV 减小量进行相关性分析,呈正相关(P<0.05)。中央拱高越大,则 ACA 和 ACV 改变量越大。结论有晶体眼后房型人工晶体 V4c 植入术后前房角变窄,前房容积下降。中央拱高与 ACA 和 ACV 改变量呈正相关,合适的拱高对保持房角开放有积极的临床意义。%Objective To observe the effect of postoperative central vault on the anterior chamber after implantation of im-plantable contact lens V4c .Methods To carry out a retrospective study of 56 eyes with implantable contact lens V4c implantation in Chongqing Bright Eye Hospital from November 2 ,2014 to February 5 ,2015 ,examined anterior chamber angle before surgery ,the anterior chamber angular width (ACA) and anterior chamber volume (ACV) were measured by pentacam .the postoperative central vault and ACA and ACV during the first and third and sixth months after surgery

  5. Cataract Surgery for Tilted Lens in Peters' Anomaly Type 2

    Directory of Open Access Journals (Sweden)

    Tadayuki Nishide

    2013-09-01

    Full Text Available Background: Cases of cataract surgery without penetrating keratoplasty in patients with Peters' anomaly are very rare. We report a case of Peters' anomaly type 2 with tilted lens due to synechia between the lens and iris that was treated with cataract surgery without penetrating keratoplasty. Case Presentation: A 16-year-old girl had Peters' anomaly in both eyes. Corneal opacity was severe in the left eye due to high-grade dysgenesis of the anterior segment. In the right eye, corneal opacity had spread from the center of the cornea to the inferotemporal side, and there was synechia between the iris and corneal endothelium from the inferonasal side to the inferotemporal side. Opacity was observed in the anterior pole of the lens, and there was synechia between the anterior iris and the lens. Ultrasound biomicroscopy (UBM revealed that the lens was tilted because of synechia. The tilted lens induced astigmatism, which reduced visual acuity to 20/250, in conjunction with a cataract. Cataract surgery was performed; the synechia between the lens capsule and the iris was severed, an intraocular lens was inserted, and the tilt was repaired. UBM was used postoperatively to confirm that the lens capsule synechia had been corrected and that the intraocular lens was not tilted. As a result, visual acuity improved to 20/100; glaucoma and expansion of corneal opacity were not observed. Conclusions: Severing of the synechia between the cataract and iris, during cataract surgery, in a patient with Peters' anomaly type 2 resulted in favorable postoperative visual acuity.

  6. Morphogenesis of the anterior segment in the zebrafish eye

    Directory of Open Access Journals (Sweden)

    Link Brian A

    2005-06-01

    Full Text Available Abstract Background The ocular anterior segment is critical for focusing incoming light onto the neural retina and for regulating intraocular pressure. It is comprised of the cornea, lens, iris, ciliary body, and highly specialized tissue at the iridocorneal angle. During development, cells from diverse embryonic lineages interact to form the anterior segment. Abnormal migration, proliferation, differentiation, or survival of these cells contribute to diseases of the anterior segment such as corneal dystrophy, lens cataract, and glaucoma. Zebrafish represent a powerful model organism for investigating the genetics and cell biology of development and disease. To lay the foundation for genetic studies of anterior segment development, we have described the morphogenesis of this structure in zebrafish. Results As in other vertebrates, the zebrafish anterior segment derives from diverse origins including surface ectoderm, periocular mesenchyme, and neuroepithelium. Similarly, the relative timing of tissue differentiation in the anterior segment is also conserved with other vertebrates. However, several morphogenic features of the zebrafish anterior segment differ with those of higher vertebrates. These include lens delamination as opposed to invagination, lack of iris muscles and ciliary folds, and altered organization in the iridocorneal angle. In addition, substantial dorsal-ventral differences exist within the zebrafish anterior segment. Conclusion Cumulatively, our anatomical findings provide a reference point to utilize zebrafish for genetic studies into the mechanisms of development and maintenance of the anterior segment.

  7. Clinical trial of anterior stromal puncture and bandage contact lens in treating patients with recurrent epithelial defects%角膜浅基质针刺术联合绷带镜治疗复发性角膜上皮糜烂

    Institute of Scientific and Technical Information of China (English)

    李晓静; 李建南

    2013-01-01

    AIM: To assess the safety and efficacy of combination therapy using anterior stromal puncture ( ASP ) and bandage contact lens for recurrent epithelial defects. METHODS:ASP was used as a treatment for 23 eyes of 22 outpatients with recurrent epithelial defects. At the mean time, they wore bandage contact lens and used eyedrops.All patients report foreign-body sensation, blepharospasm, tearing and photophobia in the morning or evening, some with visual impairment. ASP was performed on every patient with a self-made 41/2 needle under surface anesthesia.The patients worn contact lens after the surgery.We observed symptoms of foreign-body sensation, photophobia, vision , epithelial and stromal scar healing at 3d; 1,2,4,8,12wk.The average follow-up period was 3 months, range 4wk-10mo. RESULTS: Twenty -two eyes became completely asymptomatic and 19 eyes (83%) were once cured. CONCLUSION:ASP with bandage contact lens turns out to be an effective, convenient, economical and repeatable therapeutic option for patients with recurrent epithelial defects, which can control the severe foreign -body sensation quickly.%目的:探讨角膜浅基质针刺( anterior stromal puncture , ASP)联合绷带式隐形眼镜针对角膜上皮反复糜烂治疗的有效性和安全性。  方法:复发性角膜上皮糜烂的门诊患者22例23眼,最初均采用保守药物治疗无效或反复后,采用角膜浅基质针刺联合配戴绷带式隐形眼镜治疗。治疗前所有患者均表现晨起或晚间异物感、流泪、眼睑痉挛、畏光,部分伴有轻度视力下降。表面麻醉后,在裂隙灯下,用4号半针头制成截囊针形状,尖端长0.3mm,垂直穿过疏松的上皮和前弹力层行角膜浅基质多点针刺,术毕配戴月抛式绷带式隐形眼镜。在治疗后3 d;1,2,4,8,12 wk共6个时间点观察患者异物感、视力、畏光、上皮愈合情况及基质瘢痕情况。平均随访3 mo。  结果:患者22

  8. Anterior Eye Imaging with Optical Coherence Tomography

    Science.gov (United States)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  9. Effects of contact lens wearing on keratoconus: a confocal microscopy observation

    Science.gov (United States)

    Ghosh, Somnath; Mutalib, Haliza A; Sharanjeet-Kaur; Ghoshal, Rituparna; Retnasabapathy, Shamala

    2017-01-01

    AIM To evaluate the corneal cell morphology of new keratoconus patients wearing two different types of rigid gas-permeable (RGP) contact lenses for 1y. METHODS Thirty nine eyes of 39 new keratoconus patients were selected and randomly fitted with two types of RGP contact lenses. Group 1 had 21 eyes with regular rigid gas-permeable (RRGP) contact lens and rest 18 eyes were in group 2 with specially designed rigid gas-permeable (SRGP) contact lens. Corneal cell morphology was evaluated using a slit scanning confocal microscope at no-lens wear and after 1y of contact lens wearing. RESULTS After 1y of contact lens wearing in group 1, the mean anterior and posterior stromal keratocyte density were significantly less (P=0.006 and P=0.001, respectively) compared to no-lens wear. The mean cell area of anterior and posterior stromal keratocyte were also significantly different (P=0.005 and P=0.001) from no-lens wear. The anterior and posterior stromal haze increased by 18.74% and 23.81%, respectively after 1y of contact lens wearing. Whereas in group 2, statistically significant changes were observed only in cell density & area of anterior stroma (P=0.001 and P=0.001, respectively) after 1y. While, level of anterior and posterior stromal haze increased by 16.67% and 11.11% after 1y of contact lens wearing. Polymegathism and pleomorphism also increased after 1y of contact lens wearing in both the contact lens groups. CONCLUSION Confocal microscopy observation shows the significant alterations in corneal cell morphology of keratoconic corneas wearing contact lenses especially in group 1. The type of contact lens must be carefully selected to minimize changes in corneal cell morphology. PMID:28251081

  10. Rapid cooled lens cell

    Science.gov (United States)

    Stubbs, David M.; Hsu, Ike C.

    1991-12-01

    This paper describes the optomechanical design, thermal analysis, fabrication, and test evaluation processes followed in developing a rapid cooled, infrared lens cell. Thermal analysis was the key engineering discipline exercised in the design phase. The effect of thermal stress on the lens, induced by rapid cooling of the lens cell, was investigated. Features of this lens cell that minimized the thermal stress will be discussed in a dedicated section. The results of thermal analysis on the selected lens cell design and the selection of the flow channel design in the heat exchanger will be discussed. Throughout the paper engineering drawings, illustrations, analytical results, and photographs of actual hardware are presented.

  11. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  12. MALDI-MS-imaging of whole human lens capsule.

    Science.gov (United States)

    Ronci, Maurizio; Sharma, Shiwani; Chataway, Tim; Burdon, Kathryn P; Martin, Sarah; Craig, Jamie E; Voelcker, Nicolas H

    2011-08-05

    The ocular lens capsule is a smooth, transparent basement membrane that encapsulates the lens and is composed of a rigid network of interacting structural proteins and glycosaminoglycans. During cataract surgery, the anterior lens capsule is routinely removed in the form of a circular disk. We considered that the excised capsule could be easily prepared for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry imaging (MALDI-MSI) analysis. MALDI-MSI is a powerful tool to elucidate the spatial distribution of small molecules, peptides, and proteins within tissues. Here, we apply this molecular imaging technique to analyze the freshly excised human lens capsule en face. We demonstrate that novel information about the distribution of proteins by MALDI-MSI can be obtained from this highly compact connective tissue, having no evident histo-morphological characteristics. Trypsin digestion carried out on-tissue is shown to improve MALDI-MSI analysis of human lens capsules and affords high repeatability. Most importantly, MALDI-MSI analysis reveals a concentric distribution pattern of proteins such as apolipoprotein E (ApoE) and collagen IV alpha-1 on the anterior surface of surgically removed lens capsule, which may indicate direct or indirect effects of environmental and mechanical stresses on the human ocular lens.

  13. Apoptosis in the lens anlage of the heritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Tashiro, M; Baba, R; Sawaki, M; Noda, S; Fujita, M

    1998-08-01

    Adult homozygous lap mice show various eye abnormalities, such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode seems to develop normally. However, the lens vesicle progresses abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. We examined cell death in the lens anlage of this mutant. The lens anlagen of homozygous lap and normal mice from days 10 to 12 of gestation were observed by light microscopy after DNA end-labeling by immunohistochemistry and by transmission electron microscopy. By light microscopy, a slight frequency of cell death was detected in the lens anlage encircling the surface ectoderm and in the anlage or in the anlage of both homozygous lap mice and normal mice at day 10 of gestation. Cell death was seen in the lens anlage encircling the surface ectoderm in the normal mouse and sporadically in the anlage of the homozygous lap mouse at day 10.5 of gestation. Cell death was visible at the area of the lens vesicle attached to the surface ectoderm and encircling the surrounding surface ectoderm in the normal mouse, and in the lens anlage encircling the surface ectoderm and the apex areas of the lens anlage in the homozygous lap mouse at day 11 of gestation. At day 12 of gestation, almost no cell death was observed in the lens anlage of the normal mouse. However, extensive areas of cell death were still seen in the lens anlage at its apex, at the inner region, and encircling the surface ectoderm in the homozygous lap mouse. Electron microscopic observation showed that the dead cells observed in the lens anlagen by light microscopy in normal and lap mice are the result of apoptosis. In lap mice, cells with cytoplasmic condensation were observed mainly at days 10 and 10.5 of gestation. Many apoptotic bodies which had been phagocytosed by adjacent cells were seen predominantly at day 11 of gestation. At day 12 of

  14. Intraocular lens movement in anterior segment imaging system and pseudoaccommodation in eyes after phacoemulcification%人工晶体在前节OCT中的位移表现与伪调节力的研究

    Institute of Scientific and Technical Information of China (English)

    王飞; 卢奕; 汪琳

    2008-01-01

    目的 分析人工晶状体植入后生理状态下,在眼内的前后位移度及其和伪凋节力的关系.方法 选择病人46例(46只眼)行白内障超声乳化联合单焦点一体式折叠人工晶状体植入术,检测和分析术后人工晶状体在眼前节OCT图像中的位移表现,记录不同度数镜片附加时的前房深度和瞳孔直径变化值,测量患者术眼的伪凋节力,并进行相关性分析.平均随访(5.2±1.6)个月.结果 78.26%(36/46)术眼屈光矫正后近视力≥Jr5;患者术眼术后平均伪凋节力为(1.08±0.71)D.眼前节OCT图像显示附加负值镜片时人工晶状体向前位移,前房变浅,附加正值镜片时人工晶状体向后位移,前房变深,前房深度变化值为(0.26±0.09)mm;不同度数镜片附加时瞳孔直径变化值为(0.58±0.28)mm.伪凋节力与前房深度变化呈正相关(r=0.8267,P<0.01),与瞳孔直径变化亦呈正相关(r=0.6724,P<0.01).结论 白内障术后人工晶状体在生理状态下位置可前后移动,视近时睫状肌收缩、人工晶状体向前移动,是IOL眼产生伪凋节力的重要机制之一;瞳孔收缩也可部分补偿调节力.%Objective To evaluate the relationship between the position shift of posterior chamber in traocular lenses (PC IOLs) in physical condition and the amplitude of pseudoaccommodation in eyes after pacoemulcification.Methods This study analyzed 46 eyes of 46 patients after cataract surgery and PC IOLs implantation 3 months after surgery. The position shift of the IOL and radius of pupil were measured by anterior segment imaging system with different diopter spectacle plus. Pseudoaccommodation amplitude was also calculated. The relationship among pseudoaccommodation.IOL movement and pupil radius was analyzed. Results There were 78.26%(36/46 ) patients whose near visual acuity with best distance correction ≥ Jr5.With negative spectacles, IOLs moved forwards, with positive spectacles, IOLs moved backwards. The mean ACD

  15. Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens

    Science.gov (United States)

    2013-10-01

    tion that may require cataract surgery ( implantation of an intraocular lens (IOL)) are not well understood in comparison to the mature and ever-improving...showing promise, and we are confi- dent we can obtain good structural identification of lens fiber cell structure pre and post-test. This will be used...being investigated as part of the research. References MR. Banitt, JB. Malta, SL. Mian, and H.K Soong. Rupture of anterior lens capsule from blunt

  16. Linguatula serrata in the anterior chamber of the eye

    Directory of Open Access Journals (Sweden)

    Muna Bhende

    2014-01-01

    Full Text Available We report a case of intraocular Linguatula in healthy young female who presented with a history of trivial trauma, dislocated lens, inflammation and secondary glaucoma. A mobile worm was seen in the anterior chamber. Pars plana lensectomy and vitrectomy was planned to remove both the cataractous lens and the parasite during which the worm disappeared from view but was later recovered from the cassette fluid. It was identified as the nymphal form of Linguatula serrata (tongue worm.

  17. Quantitative observation on changes of anterior segment by ultrasound biomicroscopy after posterior chamber phakic intraocular lens implantation%UBM量化观察有晶状体眼后房型人工晶状体植入术前后眼前节形态的变化

    Institute of Scientific and Technical Information of China (English)

    王瑞娜; 郑广瑛; 王松田; 王洁; 赵建国; 郭红亮; 赵丽君

    2011-01-01

    ObjectiveThe objective is to study the safety and effectiveness of implantation of posterior chamber phakic intraocular contact lens (ICL) by observing the changes in anterior segment using ultrasound biomicroscopy (UBM). Methods It was a perspective study. The study sampled 30 high myopia patients (30 eyes) who were treated with posterior chamber phakic ICL implant. Central anterior chamber depth (ACD), trabecular-iris angle (TIA), angle opening distance (AOD500), trabecular-ciliary processes distance (TCPD) and iris-ciliary processes distance (ICPD) were measured using UBM preoperatively,3 months and 1 year postoperatively. The distance from ICL to the central surface of lens and peripheral lens and intra-ocular pressure were measured postoperatively and examined using slit-lamp biomicroscope. Oneway ANOVA was used to analyze the distance between peripheral surface of ICL and the lens. One-way repeated measures ANOVA and Bonferroni were conducted. Results Preoperatively, 3 months and 1 year postoperatively, ACD were(3. 16 ± 0. 08 ) mm, ( 2. 76 ± 0. 13 ) mm, (2. 74 ± 0. 14) mm; AOD500 were (0.45 + 0.04) mm, (0.41 ± 0.04) mm, (0.41 ±0.03) mm; TIA were (35.00 ±3. 24)°, (32.47 ±3.56) °, (32. 40 ± 3. 23 ) °, respectively. There were significant difference in TIA, ACD and AOD ( P <0. 05) between preoperative and postoperative data. There was no significant difference between the two postoperative periods tested. TCPD and ICPD showed no significant difference between various time points ( F =0. 49, F =0. 57 ; P > 0. 05 ). Conclusions The decrease in ACD depth and correction in TIA and AOD were the noticeable changes observed in morphological structure of the ocular anterior segment after the ICL treatment. The incidence of complication did not increase as the result of the minor changes in morph structure during the course of the study. However, the long-term effects would require further long-term observation.%目的 应用超声生物显微镜(UBM)对

  18. Cataract Surgery in Anterior Megalophthalmos: A Review

    Science.gov (United States)

    GALVIS, Virgilio; TELLO, Alejandro; M. RANGEL, Carlos

    2015-01-01

    Anterior megalophthalmos is characterized by megalocornea associated with a very broad anterior chamber and ciliary ring elongation. It is also called X-linked megalocornea. It is accompanied by early development of cataracts, zonular anomalies, and, rarely, vitreoretinal disorders. Subluxation of a cataract can occur in cataract surgery because of zonular weakness. In addition, in most patients, standard intraocular lens (IOL) decentration is a risk because of the enlarged sulcus and capsular bag. These unique circumstances make cataract surgery challenging. To date, several approaches have been developed. Implantation of a retropupillary iris-claw aphakic intraocular lens may be a good option because it is easier than suturing the IOL and can have better and more stable anatomic and visual outcomes, compared to other techniques. PMID:27350950

  19. Changes of anterior segment after early implantation of posterior chamber phakic intraocular lens for correction of high myopia%ICL植入术治疗高度近视术后早期眼前节形态的变化

    Institute of Scientific and Technical Information of China (English)

    黎冬平; 刘磊; 李新宇; 栗静; 王虎杰; 杨硕

    2014-01-01

    目的:我们应用眼前节全景分析仪( Pentacam)测量有晶状体眼后房型人工晶状体( ICL )植入术手术前后前节形态指标,评价有晶状体眼后房型人工晶状体植入术的安全性及稳定性。  方法:选取行有晶状体眼后房型人工晶状体植入术治疗的高度近视患者48例90眼,术后随访6mo。 Pentacam眼前节全景分析仪测量各时间点的中央前房深度( ACD)、3∶00位前房角( ICA)、角膜像差( CA)、角膜曲率( K)和角膜厚度(CCT)等指标。使用SPSS 19.0统计软件,描述术前术后各指标的分布特征,采用配对t检验对各指标进行手术前后的差异性比较。  结果:所有观察指标各时间点均呈正态分布。 ACD、3∶00位ICA较术前降低( P<0.05)。 CA中,总像差( CTA )及低阶像差( CLOA)较术前无统计差异( P>0.05),高阶像差(CHOA)则较术前有所增加(P<0.05);K略有减小(P<0.05)。 CCT较术前比较均无统计学差异( P>0.05)。对于术后有统计学意义变化的指标,均在术后1 mo时即达到稳定状态。  结论:应用眼前节全景分析仪( Pentacam )观察有晶状体眼后房型人工晶状体植入术眼前节形态的变化主要有ICA变窄, ACD变小, CHOA增加, K减小,尚在安全范围内,6 mo随访中各值均保持稳定,未出现并发症,但远期效果需进一步随访观察。%AIM:To evaluate safety and stability of ICL implantation treatment of high myopia through the observation of anterior segment parameters such as ACD and ICA over time pre-and post-operation changes by Pentacam. METHODS:According to the proposed inclusion criteria, 90 eyes (48 patients) with high myopia who accepted ICL implantation treatment were selected.The mean follow-ups are 6 months.Anterior segment parameters such as ACD, ICA ( 3'clock ) , corneal aberration ( CA ) , K-value and CCT were

  20. Out-of-the-bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention

    Institute of Scientific and Technical Information of China (English)

    ZHENG Dan-ying; CHEN Li-na; SUN Yi; SHAO Ying-feng; LIANG Jing-li; LIU Yi-zhi

    2010-01-01

    Background Dislocation of posterior chamber intraocular lens is one of the most common complications of intraocular lens implantation. Lens exchange is an effective solution to this unsatisfactory status. This study was conducted to analyze the possible predisposing factors for out-of-the-bag posterior chamber intraocular lens dislocation and to study the outcomes of lens exchange surgery.Methods Thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation who underwent posterior chamber intraocular lens exchange in Zhongshan Ophthalmic Center of Sun Yat-sen University (Guangdong,China) from January 2003 to October 2009 were included. A 6-month follow-up was completed. The causes for out-of-the-bag intraocular lens dislocation and visual outcomes of posterior chamber intraocular lens exchange were analyzed. The out-of-the-bag intraocular lens dislocation was diagnosed on the basis of the findings from slit-lamp microscope and B-ultrasound. The dislocated intraocular lens was explanted. Reimplantation of a new posterior chamber intraocular lens was performed in each case using standardized surgical procedures.Results In this study, a total of thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation underwent posterior chamber intraocular lens exchange surgery. Causes for out-of-the-bag intraocular lens dislocation included posterior capsule rupture during the initial cataract extraction procedure (23 eyes, 63.8%), trauma (5 eyes,13.9%), neodymium-doped yttrium aluminium garnet (Nd:YAG) laser-induced dislocation (2 eyes, 5.6%), the status after vitrectomy (2 eyes, 5.6%) and unidentifiable etiology (4 eyes, 11.1%). Symptoms of these patients mainly included decrease in visual acuity (17 cases, 47.2%), blurred vision (16 cases, 44.4%), glare (1 case, 2.8%), diplopia (1 case,2.8%), and halo (1 case, 2.8%). Intraocular lens dislocation into the posterior vitreous cavity (29 eyes, 80.5%), anterior chamber (1

  1. Anterior internal lenticonus accompanied by congenital nuclear cataract

    Institute of Scientific and Technical Information of China (English)

    LIU Zhe; SUN Chuan-bin; YAO Ke

    2011-01-01

    Internal lenticonus is a very rare morphologic abnormality of crystalline lens which has been reported in only several cases in the literature.We herein reported the clinical characteristics and surgical findings of the anterior internal lenticonus accompanied by congenital nuclear cataract.Cataract extraction accompanied with intraocular lens implantation was uneventfully performed,and a good visual outcome was achieved in this case.Viral infection during embryonal and fetal period might account for the formation of the anterior internal lenticonus and congenital nuclear cataract in our case.

  2. Contact lens in keratoconus

    OpenAIRE

    Varsha M Rathi; Preeji S Mandathara; Srikanth Dumpati

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  3. [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

    Science.gov (United States)

    Kohnen, T; Baumeister, M; Cichocki, M

    2005-10-01

    In this overview, the current status of intraocular lens surgery to correct refractive error is reviewed. The interventions are divided into additive surgery with intraocular lens implantation without extraction of the crystalline lens (phakic intraocular lens, PIOL) or the removal of the crystalline lens with implantation of an IOL (refractive lens exchange, RLE). Phakic IOLs are constructed as angle-supported or iris-fixated anterior chamber lenses and posterior chamber lenses that are fixated in the ciliary sulcus. The implantation of phakic IOLs has been demonstrated to be an effective, safe, predictable and stable procedure to correct higher refractive errors. Complications are rare and differ for the three types of PIOL; for anterior chamber lenses these are mainly pupil ovalization and endothelial cell loss.

  4. Cubic optical elements for an accommodative intraocular lens.

    Science.gov (United States)

    Simonov, Aleksey N; Vdovin, Gleb; Rombach, Michiel C

    2006-08-21

    We present a new accommodative intraocular lens based on a two-element varifocal Alvarez lens. The intraocular lens consists of (1) an anterior element combining a spherical lens for refractive power with a cubic surface for the varifocal effect, and (2) a posterior element with a cubic surface only. The focal length of the IOL lens changes when the superimposed refractive elements shift in opposite directions in a plane perpendicular to the optical axis. The ciliary muscle will drive the accommodation by a natural process of contraction and relaxation. Results of ray-tracing simulations of the model eye with the two-element intraocular lens are presented for on-axis and off-axis vision. The configuration of the lens is optimized to reduce refractive errors as well as effects of misalignment. A prototype with a clear aperture of ~5.7 mm is manufactured and evaluated in air with a Shack-Hartmann wave-front sensor. It provides an accommodation range of ~4 dioptres in the eye at a ~0.75-mm lateral displacement of the optical elements. The experimentally measured on-axis optical performance of the IOL lens agrees with the theoretically predicted performance.

  5. Fibrosis in the lens. Sprouty regulation of TGFβ-signaling prevents lens EMT leading to cataract.

    Science.gov (United States)

    Lovicu, F J; Shin, E H; McAvoy, J W

    2016-01-01

    Cataract is a common age-related condition that is caused by progressive clouding of the normally clear lens. Cataract can be effectively treated by surgery; however, like any surgery, there can be complications and the development of a secondary cataract, known as posterior capsule opacification (PCO), is the most common. PCO is caused by aberrant growth of lens epithelial cells that are left behind in the capsular bag after surgical removal of the fiber mass. An epithelial-to-mesenchymal transition (EMT) is central to fibrotic PCO and forms of fibrotic cataract, including anterior/posterior polar cataracts. Transforming growth factor β (TGFβ) has been shown to induce lens EMT and consequently research has focused on identifying ways of blocking its action. Intriguingly, recent studies in animal models have shown that EMT and cataract developed when a class of negative-feedback regulators, Sprouty (Spry)1 and Spry2, were conditionally deleted from the lens. Members of the Spry family act as general antagonists of the receptor tyrosine kinase (RTK)-mediated MAPK signaling pathway that is involved in many physiological and developmental processes. As the ERK/MAPK signaling pathway is a well established target of Spry proteins, and overexpression of Spry can block aberrant TGFβ-Smad signaling responsible for EMT and anterior subcapsular cataract, this indicates a role for the ERK/MAPK pathway in TGFβ-induced EMT. Given this and other supporting evidence, a case is made for focusing on RTK antagonists, such as Spry, for cataract prevention. In addition, and looking to the future, this review also looks at possibilities for supplanting EMT with normal fiber differentiation and thereby promoting lens regenerative processes after cataract surgery. Whilst it is now known that the epithelial to fiber differentiation process is driven by FGF, little is known about factors that coordinate the precise assembly of fibers into a functional lens. However, recent research

  6. CORRECTION OF HIGH MYOPIA WITH THE WORST MYOPIA CLAW INTRAOCULAR-LENS

    NARCIS (Netherlands)

    LANDESZ, M; WORST, JGF; SIERTSEMA, JV; VANRIJ, G

    1995-01-01

    BACKGROUND: Phakic anterior chamber lenses is one of the modalities used to correct high myopia, We report the initial results of our prospective study on the Worst myopia claw intraocular lens (IOL) that is fixated to the anterior iris, METHODS: We studied 35 eyes in 18 patients with a preoperative

  7. Superlensing Microscope Objective Lens

    CERN Document Server

    Yan, Bing; Parker, Alan; Lai, Yukun; Thomas, John; Yue, Liyang; Monks, James

    2016-01-01

    Conventional microscope objective lenses are diffraction limited, which means that they cannot resolve features smaller than half the illumination wavelength. Under white light illumination, such resolution limit is about 250-300 nm for an ordinary microscope. In this paper, we demonstrate a new superlensing objective lens which has a resolution of about 100 nm, offering at least two times resolution improvement over conventional objectives in resolution. This is achieved by integrating a conventional microscope objective lens with a superlensing microsphere lens using a 3D printed lens adaptor. The new objective lens was used for label-free super-resolution imaging of 100 nm-sized engineering and biological samples, including a Blu-ray disc sample, semiconductor chip and adenoviruses. Our work creates a solid base for developing a commercially-viable superlens prototype, which has potential to transform the field of optical microscopy and imaging.

  8. Spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium

    Directory of Open Access Journals (Sweden)

    Toshiaki Mochizuki

    2014-09-01

    Full Text Available Cell proliferation is a key regulator of tissue morphogenesis. We examined cell proliferation and cell division in zebrafish lens epithelium by visualizing cell-cycle phases and nuclear positions, using fluorescent-labeled geminin and histone proteins. Proliferation was low in the anterior region of lens epithelium and higher in the marginal zone anterior to the equator, suggesting that the proliferation zone, called the germinative zone, is formed in zebrafish lens. Interestingly, cell-division orientation was biased longitudinally in the anterior region, shifted from longitudinal to circumferential along the anterior–posterior axis of lens sphere, and was biased circumferentially in the peripheral region. These data suggest that cell-division orientation is spatially regulated in zebrafish lens epithelium. The Hertwig rule indicates that cells tend to divide along their long axes. Orientation of long axes and cell division were biased similarly in zebrafish lens epithelium, suggesting that cell geometry correlates with cell-division orientation. A cell adhesion molecule, E-cadherin, is expressed in lens epithelium. In a zebrafish e-cadherin mutant, the long axes and cell-division orientation were shifted more longitudinally. These data suggest that E-cadherin is required for the spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium.

  9. Lens regeneration in juvenile and adult rabbits measured by image analysis.

    Science.gov (United States)

    Gwon, A E; Jones, R L; Gruber, L J; Mantras, C

    1992-06-01

    Secondary cataract growth commonly occurs after extracapsular cataract extraction. The proliferation of this regrowth occurs at rates related to many factors. In this study, the authors analyzed the amount of lens regeneration after endocapsular lens extraction that leaves the anterior and posterior capsules relatively intact. The analysis was performed in New Zealand albino rabbits with the aid of image analysis measurements in young and adult animals. The effect of low vacuum suction of the anterior capsule on the growth was determined. Lens regeneration was used as a measure of the growth potential of the leftover epithelial cells in the capsule bag. The results showed that lens regeneration was significantly faster in younger rabbits. However, low vacuum suction had no effect on the growth rate. Potential therapeutic agents for preventing secondary cataracts may be better analyzed with image analysis processing of lens regeneration, a precise and rapid measurement technique.

  10. c-myc Regulates Cell Proliferation during Lens Development

    Science.gov (United States)

    Gomes, Anielle L.; Rodrigues, Paulo M. G.; Martins, Rodrigo A. P.

    2014-01-01

    Myc protooncogenes play important roles in the regulation of cell proliferation, growth, differentiation and survival during development. In various developing organs, c-myc has been shown to control the expression of cell cycle regulators and its misregulated expression is detected in many human tumors. Here, we show that c-myc gene (Myc) is highly expressed in developing mouse lens. Targeted deletion of c-myc gene from head surface ectoderm dramatically impaired ocular organogenesis, resulting in severe microphtalmia, defective anterior segment development, formation of a lens stalk and/or aphakia. In particular, lenses lacking c-myc presented thinner epithelial cell layer and growth impairment that was detectable soon after its inactivation. Defective development of c-myc-null lens was not caused by increased cell death of lens progenitor cells. Instead, c-myc loss reduced cell proliferation, what was associated with an ectopic expression of Prox1 and p27Kip1 proteins within epithelial cells. Interestingly, a sharp decrease in the expression of the forkhead box transcription factor Foxe3 was also observed following c-myc inactivation. These data represent the first description of the physiological roles played by a Myc family member in mouse lens development. Our findings support the conclusion that c-myc regulates the proliferation of lens epithelial cells in vivo and may, directly or indirectly, modulate the expression of classical cell cycle regulators in developing mouse lens. PMID:24503550

  11. c-Myc regulates cell proliferation during lens development.

    Directory of Open Access Journals (Sweden)

    Gabriel R Cavalheiro

    Full Text Available Myc protooncogenes play important roles in the regulation of cell proliferation, growth, differentiation and survival during development. In various developing organs, c-myc has been shown to control the expression of cell cycle regulators and its misregulated expression is detected in many human tumors. Here, we show that c-myc gene (Myc is highly expressed in developing mouse lens. Targeted deletion of c-myc gene from head surface ectoderm dramatically impaired ocular organogenesis, resulting in severe microphtalmia, defective anterior segment development, formation of a lens stalk and/or aphakia. In particular, lenses lacking c-myc presented thinner epithelial cell layer and growth impairment that was detectable soon after its inactivation. Defective development of c-myc-null lens was not caused by increased cell death of lens progenitor cells. Instead, c-myc loss reduced cell proliferation, what was associated with an ectopic expression of Prox1 and p27(Kip1 proteins within epithelial cells. Interestingly, a sharp decrease in the expression of the forkhead box transcription factor Foxe3 was also observed following c-myc inactivation. These data represent the first description of the physiological roles played by a Myc family member in mouse lens development. Our findings support the conclusion that c-myc regulates the proliferation of lens epithelial cells in vivo and may, directly or indirectly, modulate the expression of classical cell cycle regulators in developing mouse lens.

  12. Hypoplastic basement membrane of the lens anlage in the inheritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Baba, R; Noda, S; Ikuno, S; Fujita, M

    2000-04-01

    Adult homozygous lap mice show various eye abnormalities such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode appears to develop normally. However, the lens vesicle develops abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. Apoptotic cell death is associated with the disappearance of the lens anlage. We examined the basement membranes of the lens anlage of this mutant by immunohistochemical methods under light microscopy using antibodies against basement membrane components of the lens anlage, type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan, and entactin and by transmission electron microscopy. Immunohistochemistry showed the distribution and intensity of antibody binding to the lens anlage to be almost the same for each these antibodies regardless of the stage of gestation or whether the anlagen were from normal BALB/c or lap mice. Thus, positive continuous reactions were observed around the exterior region of the lens anlage from day 10 of gestation for type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan antibodies, and at least from day 11of gestation for entactin antibody. The basement membrane lamina densa of both normal and lap mice was shown by electron microscopy to be discontinuous at days 10 and 10.5 of gestation. However, by day 11 the lamina densa was continuous in the lens anlagen of normal mice but still discontinuous in the lap mice. By day 12 of gestation, the lamina densa had thickened markedly in normal mice, whereas in lap mice it remained discontinuous and its thinness indicated hypoplasia. These results indicate that, while all basement components examined are produced and deposited in the normal region of the lens anlage in the lap mouse, the basement membrane is, for some reason, imperfectly formed. The time at which hypoplasia of the basement membrane was observed

  13. Unitary lens semiconductor device

    Science.gov (United States)

    Lear, Kevin L.

    1997-01-01

    A unitary lens semiconductor device and method. The unitary lens semiconductor device is provided with at least one semiconductor layer having a composition varying in the growth direction for unitarily forming one or more lenses in the semiconductor layer. Unitary lens semiconductor devices may be formed as light-processing devices such as microlenses, and as light-active devices such as light-emitting diodes, photodetectors, resonant-cavity light-emitting diodes, vertical-cavity surface-emitting lasers, and resonant cavity photodetectors.

  14. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  15. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  16. [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

    Science.gov (United States)

    Kohnen, T; Kasper, T; Terzi, E

    2005-11-01

    In this overview, the current status of intraocular lens surgery to correct refractive error is reviewed. The interventions are divided into additive surgery with intraocular lens implantation without extraction of the crystalline lens (phakic intraocular lens, PIOL) or removal of the crystalline lens with implantation of an IOL (refractive lens exchange, RLE). Phakic IOLs are constructed as angle-supported or iris-fixated anterior chamber lenses and posterior chamber lenses which are fixated in the ciliary sulcus. The implantation of phakic IOLs has been demonstrated to be an effective, safe, predictable and stable procedure to correct higher refractive errors. Complications are rare and differ for the three types of PIOL; for posterior chamber lenses these are mainly cataract formation and pigment dispersion. RLE is preferable in cases of high ametropia in which the natural lens has lost its accommodative effect. The main complications for myopic RLA include retinal detachment, while hyperopic refractive lens exchange may be associated with surgical problems in the narrower anterior eye segment.

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Lens-Related Eye Infections Mar 01, 2017 New Technology Helps the Legally Blind Be More Independent Oct ... easy answer, and neither one considers long-term impacts. Phakic Intraocular Lenses for Nearsightedness FEB 27, 2017 ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lenses without a prescription in the United States. All contact lenses are medical devices that require a ... no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal abrasion. ... Studies Look at Effects of Marijuana on Vision FEB ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... 2016 More Eye Health News Studies Look at Effects of Marijuana on Vision FEB 28, 2017 By ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens-Related Eye Infections Mar 01, 2017 New Technology Helps the Legally Blind Be More Independent ... Worse? May 16, 2016 More Eye Health News New Dry Eye Treatment is a Tear-Jerker JUL ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Healthy Contact Lens Use May 31, 2016 Is El Niño Making Your Allergies Worse? May 16, 2016 ... Number: * Email: * Enter code: * Message: Thank you Your feedback has been sent.

  10. Histological observation of complete closure of anterior capsulotomy in 2 cases.

    Science.gov (United States)

    Tanaka, Sai-Ichi; Saika, Shizuya; Tamura, Manabu; Ohnishi, Yoshitaka

    2004-06-01

    We report the histological finding of complete closure of the anterior capsulotomy window in 2 cases. The cases were successfully treated with surgery after neodymium:YAG laser anterior capsulotomy failed. Histology and immunohistochemistry were performed to determine the pathogenesis. Histology revealed the presence of elongated, fibroblast-like lens epithelial cells in association with extracellular matrix accumulation, which were positive for collagen types, fibronectin, and osteopontin. The cells were labeled with anti-alpha-smooth muscle actin antibody. The finding indicates that phenotypic modulation in lens epithelial cell to contractile cell type and accumulation of matrix are involved in closure of the anterior capsulotomy window.

  11. In-the-bag decentration of an intraocular lens in a patient with a tendency to hypertrophic scarring

    Science.gov (United States)

    Joshi, Rajesh Subhash

    2016-01-01

    Summary We report a case of rapid anterior lens capsular contraction leading to decentration of a hydrophilic acrylic lens with stiff haptics (Rayner design). To our knowledge, this is the first report to investigate early capsular contraction with folding of the haptic over the optic in a patient with a tendency toward hypertrophic scar formation. PMID:27330480

  12. Unilateral persistent fetal vasculature coexisting with anterior segment dysgenesis.

    Science.gov (United States)

    Khokhar, Sudarshan; Gupta, Shikha; Arora, Tarun; Gogia, Varun; Dada, Tanuj

    2013-08-01

    Persistent fetal vasculature (PFV) is a common congenital developmental anomaly of the eye which results from failure of the embryological primary vitreous and hyaloid vasculature to regress by the time of birth (Int Ophthalmol Clin 48: 53-62, 2008). Typically, it is divided into anterior, posterior or combined types and is characterized by the presence of a vascular stalk located between the optic disc and the posterior lens capsule (Int Ophthalmol Clin 48: 53-62, 2008). Although it has been reported to manifest itself differently, in our case it presented in a microphthalmic eye as anterior segment dysgenesis with broad-based mid-peripheral synechiae, posterior embryotoxon, iridoschisis, ectropion uveae, hypotony and subluxated cataractous lens with a taut anterior hyaloid face which are rare associations with PFV.

  13. Biometric, optical and physical changes in the isolated human crystalline lens with age in relation to presbyopia.

    Science.gov (United States)

    Glasser, A; Campbell, M C

    1999-06-01

    The biometric, optical and physical properties of 19 pairs of isolated human eye-bank lenses ranging in age from 5 to 96 years were compared. Lens focal length and spherical aberration were measured using a scanning laser apparatus, lens thickness and the lens surface curvatures were measured by digitizing the lens profiles and equivalent refractive indices were calculated for each lens using this data. The second lens from each donor was used to measure resistance to physical deformation by providing a compressive force to the lens. The lens capsule was then removed from each lens and each measurement was repeated to ascertain what role the capsule plays in determining these optical and physical characteristics. Age dependent changes in lens focal length, lens surface curvatures and lens resistance to physical deformation are described. Isolated lens focal length was found to be significantly linearly correlated with both the anterior and posterior surface curvatures. No age dependent change in equivalent refractive index of the isolated lens was found. Although decapsulating human lenses causes similar changes in focal length to that which we have shown to occur when human lenses are mechanically stretched into an unaccommodated state, the effects are due to nonsystematic changes in lens curvatures. These studies reinforce the conclusion that lens hardening must be considered as an important factor in the development of presbyopia, that age changes in the human lens are not limited to the loss of accommodation that characterizes presbyopia but that the lens optical and physical properties change substantially with age in a complex manner.

  14. Anterior dislocation of an empty capsular bag in a pseudophakic eye: A rare case report

    Directory of Open Access Journals (Sweden)

    Hyung Bin Hwang

    2015-01-01

    Full Text Available Spontaneous intraocular lens (IOL dislocation is uncommon in the absence of any ocular areas with zonular weakness or trauma. There have been no reports of spontaneous capsular bag dislocation into the anterior chamber without an IOL. We report a rare, interesting case of spontaneous capsular bag anterior dislocation, without an IOL, into the anterior chamber with no history of genetic disease, ocular trauma, or pseudoexfoliation that might predispose to a zonular abnormality.

  15. Changes of ocular anterior segment on morphology after implantation of the implantable collamer lens for high myopia%有晶状体眼后房型人工晶状体植入术后眼前节形态学观察

    Institute of Scientific and Technical Information of China (English)

    容维宁; 孙燕; 郭慧青; 徐惠芳; 贾沁; 梁静; 殷莉; 周玲婕; 盛迅伦

    2015-01-01

    Objective To assess the effect on anterior chamber angle,corneal endothelial and adjacent tissue after implantation of phakic posterior chamber implantable collamer lens (PPC-ICL) for the correction of high myopia.Methods In this prospective,nonrandomized clinical study,106 consecutive eyes of 58 patients with high myopic received ICL implantation between January 2011 and June 2013 in the Ningxia Eye Hospital.Uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA),intraocular pressure,corneal endothelial cell count were measured preoperatively and at 1 month,6 months and 12 months postoperatively.The ultrasound biomicroscopy (UBM) was used to observe the depth of anterior chamber (ACD) vault,angle opening distance 500 microns from the scleral spur (AOD500),trabecular-iris angle (TIA) at point 2,4,8 and 10 respectively.The repeated measurement ANOVA was used to analyzed statistical data.Results The postoperative UCVA was equally or higher compare with preoperative BCVA in all patients.Intraocular pressure and corneal endothelial cell count were no statistically significant difference between pre-and postoperative (P>0.05).The postoperaive ACD,AOD500 and TIA value were decreased significantly than preoperative at 1 month (F=12.372,21.393,22.076,21.154,21.763,19.471,19.823,19.836,19.247,P<0.05).But there were no statistically significant difference of ACD,AOD500,vault and TIA between 1-month and 6-month,12-month postoperatively.No pupillary block glaucoma or anterior capsule opacification occurred during the follow-up.Conclusion The structure of anterior chamber angle was stable and corneal endothelial cell was no obvious decrease postoperatively during 1 year follow-up.%目的 观察有晶状体眼后房型人工晶状体(PPC-ICL)植入术治疗高度近视后眼前节形态学变化,探讨PPC-ICL植入术对前房角、角膜内皮以及邻近组织的影响.方法 前瞻性研究.收集2011年1月至2013年6月在宁夏眼科医院行PPC-ICL

  16. Treatment of a dislocated lens by transcorneal vitrectomy and bimanual phacoemulsification

    Directory of Open Access Journals (Sweden)

    Watanabe A

    2014-08-01

    Full Text Available Akira Watanabe, Tamaki Gekka, Hiroshi Tsuneoka Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan Background: As a method of treatment for a dropped lens nucleus, which occurred during cataract surgery, the dropped lens nucleus was removed through the corneal wound without using pars plana vitrectomy (PPV. After vitrectomy, the dropped lens nucleus was floated on the perfluorocarbon liquid (PFCL. The floating lens nucleus was then phacoemulsified and aspirated. During surgery, irrigation from the anterior chamber was performed. This method was very effective for treatment of a dropped hard nucleus.Case report: During cataract surgery on the left eye of an 80-year-old woman, a posterior capsule rupture occurred. As a result, the lens nucleus dropped into the vitreous cavity. Irrigation to the anterior chamber was performed, with an anterior chamber maintainer inserted through a newly created side port at the corneal limbus. A vitreous cutter and a light guide were inserted in order to perform vitrectomy through the corneal incisions that were created for the cataract surgery. After vitrectomy, the dropped lens nucleus was floated using PFCL. The floating lens nucleus was removed by a bimanual phacoemulsification technique, with the anterior chamber irrigation continuing. The separation of the irrigation port and the aspiration port allowed for effective treatment of the dropped nucleus that was floating on the PFCL, even using a ­phacoemulsification machine with a peristaltic pump system. Safe and effective vitrectomy, similar to a PPV, could be performed with this method using three corneal ports.Conclusion: This technique may allow safer and more effective treatment for a dropped lens nucleus compared with conventional PPV. With this technique, corneal distortion due to surgical manipulation can lead to reduced visibility of the posterior eye. Keywords: dislocated lens, transcorneal vitrectomy, bimanual

  17. Contact lens-related acanthamoeba keratitis.

    Science.gov (United States)

    Stapleton, Fiona; Ozkan, Jerome; Jalbert, Isabelle; Holden, Brien A; Petsoglou, Con; McClellan, Kathy

    2009-10-01

    Acanthamoeba keratitis is a rare but severe disease, with more than 95% of cases occurring in contact lens wearers. With a worldwide resurgence of contact lens-related disease, this report illustrates the clinical characteristics and treatment challenges representative of this disease. This report describes Acanthamoeba keratitis in a 47-year-old female using extended wear silicone hydrogel contact lenses, with a history of swimming in a home pool and failure to subsequently disinfect the contact lenses. The diagnosis was based on clinical signs, disease course, and confocal microscopy results despite a negative result for corneal smear and culture. The corneal signs included an epithelial defect, epithelial irregularities, anterior stromal infiltrates, perineural infiltrates, an anterior stromal ring infiltrate, and hypopyon. The case was diagnosed as an infective keratitis and treated promptly using intensive topical administration of fortified gentamicin and cephalothin. The high likelihood Acanthamoeba prompted immediate use of polyhexamethylbiguanide and chlorhexidine, with propamide and adjunct treatment using atropine and oral diclofenac. Steroids were added on day 3, and the frequency of administration of antibacterial treatment was gradually reduced and ceased by day 10. The analgesia was stopped at 3 months. The frequency of administration of antiamoeba therapy and steroid treatment was slowly reduced and all treatment was ceased after 18 months. Despite considerable morbidity in terms of the treatment duration, hospitalization, outpatient appointments, and associated disease costs, the final visual outcome (6/6) was excellent.

  18. 有晶状体眼后房型人工晶状体植入术后前房角的变化及其相关因素%The change in anterior chamber angle and related factors in collamer lens implantation

    Institute of Scientific and Technical Information of China (English)

    朱浩斌; 贾琰; 周激波

    2014-01-01

    目的 研究高度近视眼植入有晶状体眼后房型人工晶状体(PPC-ICL)后前房角(ACA)的变化及其相关因素.方法 前瞻性研究.收集2013年3月至2014年4月在上海交通大学医学院附属第九人民医院行PPC-ICL植入手术的中高度近视患者26例(45眼).术后平均随访(4.3±3.2)个月.Pentacam测量术前及术后ACA、前房深度、角膜曲率、PPC-ICL拱高(vault).IOLMaster测量白到白距离和眼轴长度.同时记录术前及术后UCVA、等效球镜度及IOP.采用配对t检验、Wilcoxon符号秩和检验、Pearson相关、Spearman秩相关、多元回归分析进行数据分析.结果 3点方位术后ACA宽度为27.44°-±5.24°,与术前43.23°±5.72°比较,差异有统计学意义(Z=-5.841,P<0.01).3点方位ACA宽度的变化量与PPC-ICL拱高、同方位术前ACA宽度呈正相关(r=0.556、0.530,P<0.01),术后ACA宽度与拱高、术前ACA宽度回归方程为ACA术后=4.860-0.009 vault±0.621 ACA术前(F=20.032,P<0.01).9点方位ACA宽度术后为26.82°±4.73°,与术前42.40°±5.81°比较,差异有统计学意义(t=20.890,P<0.01);9点方位ACA宽度的变化量与PPC-ICL拱高、同方位术前ACA宽度呈正相关(r=0.581、0.626,P<0.01),术后ACA宽度和拱高、术前ACA宽度回归方程为ACA术后=5.767-0.008 vault±0.586 ACA术前(F=24.775,P<0.01).结论 PPC-ICL植入术后水平方向ACA宽度显著变小,变化量和术前ACA宽度、拱高均呈正相关.%Objective To investigate the change in the anterior chamber angle and to analyze its related factors of phakic posterior chamber implantable collamer lens (PPC-ICL) implantation.Methods Twenty-six moderate and high myopic patients (45 eyes) who received PPC-ICL implants from March 2013 to April 2014 were included in this prospective study.The mean follow-up time was 4.3±3.2 months.Anterior chamber angle (ACA),anterior chamber depth (ACD),corneal curvature,and vault were measured with a Pentacam preoperatively and

  19. Dose conversion coefficients for neutron exposure to the lens of the human eye

    Energy Technology Data Exchange (ETDEWEB)

    Manger, Ryan P [ORNL; Bellamy, Michael B [ORNL; Eckerman, Keith F [ORNL

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10{sup -9} to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  20. A gradient of matrix-bound FGF-2 and perlecan is available to lens epithelial cells.

    Science.gov (United States)

    Wu, Weiju; Tholozan, Frederique M; Goldberg, Martin W; Bowen, Leon; Wu, Junjie; Quinlan, Roy A

    2014-03-01

    Fibroblast growth factors play a key role in regulating lens epithelial cell proliferation and differentiation via an anteroposterior gradient that exists between the aqueous and vitreous humours. FGF-2 is the most important for lens epithelial cell proliferation and differentiation. It has been proposed that the presentation of FGF-2 to the lens epithelial cells involves the lens capsule as a source of matrix-bound FGF-2. Here we used immunogold labelling to measure the matrix-bound FGF-2 gradient on the inner surface of the lens capsule in flat-mounted preparations to visualize the FGF-2 available to lens epithelial cells. We also correlated FGF-2 levels with levels of its matrix-binding partner perlecan, a heparan sulphate proteoglycan (HSPG) and found the levels of both to be highest at the lens equator. These also coincided with increased levels of phosphorylated extracellular signal-regulated kinase 1 and 2 (pERK1/2) in lens epithelial cells that localised to condensed chromosomes of epithelial cells that were Ki-67 positive. The gradient of matrix-bound FGF-2 (anterior pole: 3.7 ± 1.3 particles/μm2; equator: 8.2 ± 1.9 particles/μm2; posterior pole: 4 ± 0.9 particles/μm2) and perlecan (anterior pole: 2.1 ± 0.4 particles/μm2; equator: 5 ± 2 particles/μm2; posterior pole: 1.9 ± 0.7 particles/μm2) available at the inner lens capsule surface was measured for the bovine lens. These data support the anteroposterior gradient hypothesis and provide the first measurement of the gradient for an important morphogen and its HSPG partner, perlecan, at the epithelial cell-lens capsule interface.

  1. Lens siderosis resulting from a small intralenticular metallic foreign body

    Directory of Open Access Journals (Sweden)

    Shah, Mehul A.

    2015-11-01

    Full Text Available We report a rare case of lens siderosis with an undetectable intraocular foreign body by imaging. An 8-year-old boy presented with diminution of vision in the left eye since 3 months. His parents gave a preceding uncertain history of a foreign body injury to his left eye 3 months ago while playing. Presenting visual acuity in the left eye was perception of hand movements. Slit-lamp examination revealed a total white cataract with brownish-pigmented spots on the anterior capsule of the lens, but no intraocular foreign body was found. There was also no evidence of an intraocular foreign body on ultrasonography. Patient underwent cataract extraction with intraocular lens implantation. During the operation, a small (2×1×1 mm in size intralenticular foreign body of metal material was found and removed carefully with a magnet. The patient regained 20/30 vision after surgery.

  2. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  3. Thin Lens Ray Tracing.

    Science.gov (United States)

    Gatland, Ian R.

    2002-01-01

    Proposes a ray tracing approach to thin lens analysis based on a vector form of Snell's law for paraxial rays as an alternative to the usual approach in introductory physics courses. The ray tracing approach accommodates skew rays and thus provides a complete analysis. (Author/KHR)

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Lens Use May 31, 2016 Is El Niño Making Your Allergies Worse? May 16, 2016 More Eye ... EyeSmart Embed EyeSmart videos on your website Promotional materials for eye health observances EyeSmart resources are also ...

  5. Foldable Lens Explantation and Exchange:The Reason and Solution

    Institute of Scientific and Technical Information of China (English)

    Danying Zheng; Zhenpin Zhang; Wenhui Yang; Weirong Chen

    2001-01-01

    Objective: To report the explantation and exchange of Hydrophilic Acrylic foldable intraocular lens (IOL) on 14 patients who had visual disturbances caused by the change of transparence on optic. Methods: Sixteen Hydrophilic Acrylic foldable intraocular lenses from 14 patients who presented with decreased visual acuity from 6 months to 1 year after normal phacoemulsification and IOL implantation associated with extensive transparent change on optic of the lens. The lenses were explanted with the bisection technique. All the eyes were reinserted with Acrysof foldable lenses. Results: Sixteen lenses were removed successfully and exchanged with the new lens in the capsule. The posterior capsular rupture and vitreous loss were found in the first two cases. One of them had the zonulysis due to the radial tear of the anterior capsule during the enlargement of the capsular opening. The anterior vitrectomy was performed with IOL fixed on the ciliary sulcus. The visual acuity of all the patients improved obviously without posterior complication. Conclusion: Foldable lens explantation with the bisection technique and exchange had a successful outcome with improvement of ocular condition. Eye science 2001; 17:54 ~56.

  6. Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Ayong Yu; Zhende Lin; Xiaoyu Cai; Xiuqi Chen; Shuke Luo; Yonghua Li

    2006-01-01

    Purpose: To study in situ the intraocular position of iris-claw phakic intraocular lens (ICPIOL) in myopic eyes using ultrasound biomicroscopy (UBM).Methods: UBM echograms of the anterior segment were taken preoperatively and 62to 115 days postoperatively in 6 eyes implanted with the Verisys ICPIOL (AMO). The echograms were assessed for the effect of the ICPIOL on iris tissue.Results: The preoperative distance between the corneal endothelium and the lens ranged from 2.96 to 3.09 mm, and the postoperative distance between the ICPIOL and the corneal endothelium, from 1.86 to 2.03 mm. The distance between the lens and the posterior surface of the ICPIOL ranged from 0.61 to 0.76 mm. The distance between the superior, inferior optic edge and the iris ranged from 0.49 to 1.00 mm,0.21 to 0.51 mm respectively. The shortest distance between the ICPIOL haptics and the angle of anterior chamber ranged from 1.25 to 1.65 mm. The indentation of iris tissue by the ICPIOL haptics without pigmentary dispersion and distortion of posterior curvature of iris was observed.Conclusion: Adequate space is maintained between the Verisyse myopic ICPIOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris without pigment erosion and distortion of iris curvature is noted. The ICPIOL implanted in phakic eyes is a safe alternative for treatment of high myopia.

  7. Management of posteriorly dislocated crystalline lens with perfluorocarbon liquid and fibrin glue-assisted scleral-fixated intraocular lens implantation.

    Science.gov (United States)

    Lee, Soo Jung; Kim, In Geun; Park, Jung Min

    2013-03-01

    We describe a technique that uses a 23-gauge transconjunctival sutureless vitrectomy with perfluorocarbon liquid (PFCL) and phacoemulsification to manage a dropped nucleus. The PFCL is injected into the vitreous space until the dislocated lens reaches the iris plane and is then removed using phacoemulsification in the anterior chamber. After intraocular lens (IOL) implantation, a 23-gauge forceps is passed through the sclerotomy to grasp the IOL haptic, which is pulled onto the ocular surface. Tunnels are made at the edge of the flap with a 26-gauge needle into which the 2 haptics are tucked for additional stability. The scleral flaps and conjunctiva are then glued using biological glue. Perfluorocarbon liquid reduces lens repulsion and blocks the transmission of the ultrasound stream to the retina. The fibrin glue-assisted sutureless IOL implantation technique could reduce complications and suture-related problems.

  8. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  9. CONGENITAL ANTERIOR TIBIOFEMURAL SUBLUXATION

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2008-06-01

    Full Text Available Congenital anterior tibiofemoral subluxation is an extremely rare disorder. All reported cases accompanied by other abnormalities and syndromes. A 16-year-old high school girl referred to us with bilateral anterior tibiofemoral subluxation as the knees were extended and reduced at more than 30 degrees flexion. Deformities were due to tightness of the iliotibial band and biceps femuris muscles and corrected by surgical release. Associated disorders included bilateral anterior shoulders dislocation, short metacarpals and metatarsals, and right calcaneuvalgus deformity.

  10. Modified technique of endocapsular lens aspiration for severely subluxated lenses.

    Science.gov (United States)

    Khokhar, S; Aron, N; Yadav, N; Pillay, G; Agarwal, E

    2017-08-11

    PurposeSeverely subluxated crystalline lenses pose a difficult situation to anterior segment surgeons and can only be managed surgically by removal of the lens as well as the capsular bag. Several techniques have been described in literature for the management of such cases. We describe a modified technique of endocapsular lens aspiration by the limbal route for lens extraction through small incisions on the cornea.Patients and methodsThirty-two eyes of 16 consecutive patients with severely subluxated crystalline lenses were recruited in the study. All eyes underwent a modified technique of lens aspiration within the capsular bag using a single instrument, vitrectomy cutter, and irrigation cannula, followed by sacrificing of the capsular bag. The patients were either left aphakic or implanted with an open loop anterior chamber intraocular lens (ACIOL Kelman Multiflex) and prospectively followed up for a period of 3 months.ResultsThe mean age of the patients was 9 years 3 months±3 years (range 5-15 yrs). All eyes underwent complete lens aspiration within the capsular bag with no dislocation of the lens matter. ACIOL was inserted in 22 eyes (68.7%) and 10 eyes (31.2%) were left aphakic. All the surgeries were uneventful. The mean best corrected visual acuity (BCVA) at 3 months post surgery was 0.47±0.11 logMAR which was significantly better than pre-operative BCVA (P=0.001). The percentage endothelial cell loss at 3 months was 7.1%. There was no evidence of glaucoma, corneal decompensation, or retinal detachment. The astigmatism which increased from 1.45D±086 preoperatively to 3.76D±2.02 1 week post-operatively due to sutures reduced to 1.97D±0.81 post suture removal at 3 months.ConclusionThe modified technique of endocapsular lens aspiration proves to be a simple and effective method of removal of the lens-capsular bag complex in severely subluxated lenses.Eye advance online publication, 11 August 2017; doi:10.1038/eye.2017.160.

  11. Application and experience of anterior vitrectomy in phacoemulsification

    Directory of Open Access Journals (Sweden)

    Xiao-Bo Zeng

    2016-02-01

    Full Text Available AIM: To observe and discuss the clinical application and effect of anterior vitrectomy in phacoemulsification for the treatment of vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection.METHODS:Retrospective analysis of 28 cases(35 eyeswith cataract in whom vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and intraocular lens implantation and anterior vitrectomy were performed was conducted. RESULTS:Anterior vitrectomy for timely and accurate treatment for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification was satisfied. CONCLUSION: Anterior vitrectomy has good curative effect for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and is effective with less severe complications.

  12. Transglutaminase involvement in UV-A damage to the eye lens.

    Science.gov (United States)

    Weinreb, O; Dovrat, A

    1996-11-01

    Solar radiation is believed to be one of the major environmental factors involved in lens cataractogenesis. The purpose of the study was to investigate the mechanisms by which UV-A at 365 nm causes damage to the eye lens. Bovine lenses were placed in special culture cells for pre-incubation of 24 hr. The lenses were positioned so that the anterior surface faced the incident UV-A radiation source and were maintained in the cells during irradiation. After irradiation, lens optical quality was monitored throughout the culture period and lens epithelium, cortex and nuclear samples were taken for biochemical analysis. Transglutaminase activity in the lens was affected by the radiation. The activity of transglutaminase in lens epithelium cortex and nucleus increased as a result of the irradiation and then declined towards control levels during the culture period, as the lens recovered from the UV-A damage. Specific lens proteins, alpha B and beta B1 crystallins (the enzyme substrates) were analyzed by SDS polyacrylamide gel electrophoresis and immunoblotting with specific antibodies. Seventy-two hours after irradiation of 44.8 J cm-2 UV-A, alpha B crystallins were affected as was shown by the appearance of aggregation and degradation products. Some protein changes seem to be reversible. It appears that transglutaminase may be involved in the mechanism by which UV-A causes damage to the eye lens.

  13. Coherent fiber optic sensor for early detection of cataractogenesis in a human eye lens

    Science.gov (United States)

    Dhadwal, Harbans S.; Ansari, Rafat R.; Dellavecchia, Michael A.

    1993-01-01

    A lensless backscatter fiber optic probe is used to measure the size distribution of protein molecules inside an excised, but intact, human eye lens. The fiber optic probe, about 5 mm in diameter, can be positioned arbitrarily close to the anterior surface of the eye; it is a trans-receiver, which delivers a Gaussian laser beam into a small region inside the lens and provides a coherent detection of the laser light scattered by the protein molecules in the backward direction. Protein sizes determined from the fast and slow diffusion coefficients show good correlation with the age of the lens and cataractogenesis.

  14. Anterior chamber lenses. Part II: A laboratory study.

    Science.gov (United States)

    Apple, D J; Hansen, S O; Richards, S C; Ellis, G W; Kavka-Van Norman, D; Tetz, M R; Pfeffer, B R; Park, R B; Crandall, A S; Olson, R J

    1987-03-01

    An analysis of 606 surgically removed anterior chamber intraocular lens (IOL) specimens revealed that 351 or 58% of these were small-diameter, round loop, closed-loop styles. Because of the extremely high percentage of IOLs with this design received in our laboratory and the correlation of clinical histories with our histopathologic findings, we have concluded that such IOLs do not provide the safety and efficacy achieved by other anterior chamber lens designs. The finely polished, one-piece, all-PMMA styles fared well in our study. Although these one-piece styles comprise well over 50% of the American market share of anterior chamber IOLs, they comprise only 14% of all anterior chamber IOLs accessioned in our laboratory, compared to 58% for closed-loop designs. We believe that implantation of anterior chamber lenses with small-diameter, round, closed loops is no longer warranted. Patients in whom these IOLs have already been implanted should be carefully followed. It is our opinion that the FDA should recall or closely monitor all IOLs of this design and that implantation of closed-loop lenses should be discontinued in the United States. Furthermore, we believe that an IOL deemed to be not medically sound or worthy of implantation in the United States should not be marketed or donated outside of this country.

  15. Allogeneic split-skin grafting in stem cell transplanted patients

    DEFF Research Database (Denmark)

    Olsen, Jan Kyrre Berg; Vindeløv, Lars; Schmidt, G.

    2008-01-01

    SUMMARY: We present a unique case of a bone marrow stem cell transplanted (BMT) patient with cutaneous chronic Graft versus Host Disease (cGvHD) who underwent successful allogeneic split-thickness skin graft (STSG) transplantation. BMT had previously been carried out due to myelodysplasia and non......). Allogeneic skin grafts are known to be acutely rejected. Successful allogeneic STSG has only been reported in sporadic cases of identical twins (isotransplantation). This case is the first to demonstrate what works in theory: the immune system of a stem cell transplanted patient with 100% or mixed stable...... to a full thickness ulceration on the entire scalp. From the femoral region of the donating sister a STSG was harvested under local analgesia and transplanted without analgesia to the prepared scalp ulcer of the recipient. The result was full and permanent take of the allogeneic STSG (follow up: three years...

  16. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  17. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-01-01

    Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932

  18. Results of cataract surgery and plasma ablation posterior capsulotomy in anterior persistent hyperplastic primary vitreous.

    Science.gov (United States)

    Sinha, Rajesh; Bali, Shveta Jindal; Kumar, Chandrashekhar; Shekhar, Himanshu; Sharma, Namrata; Titiyal, Jeewan S; Vajpayee, Rasik B

    2013-01-01

    To report the feasibility and outcome of lens aspiration, and Fugo blade-assisted capsulotomy and anterior vitrectomy in eyes with anterior persistent hyperplastic primary vitreous (PHPV). In this case series, 10 eyes of 10 patients with anterior PHPV underwent lens aspiration. The vascularized posterior capsule was cut with a Fugo blade (plasma knife) and removed with a vitrector. A foldable posterior chamber intraocular lens (IOL) was implanted in eight eyes and the outcomes were evaluated. The mean age of patients was 16.8 ± 6.37 months (range: 5 to 28 months). The surgery was completed successfully in all eyes. There were no cases of intraocular hemorrhage intraoperatively. Foldable acrylic IOL was implanted in the bag in 3 eyes and in the sulcus in 5 eyes. Two eyes were microphthalmic and did no undergo IOL implantation (aphakic). None of the eyes had a significant reaction or elevated intraocular pressure postoperatively. The follow-up ranged from 4 to 21 months. All the pseudophakic eyes achieved a best corrected visual acuity of ≥20/200 with 50% (4/8) of these eyes with ≥20/60 vision. Lens aspiration followed by posterior capsulotomy with Fugo blade-assisted plasma ablation is a feasible technique for performing successful lens surgery in cases with florid anterior PHPV.

  19. Results of cataract surgery and plasma ablation posterior capsulotomy in anterior persistent hyperplastic primary vitreous

    Directory of Open Access Journals (Sweden)

    Rajesh Sinha

    2013-01-01

    Full Text Available Purpose: To report the feasibility and outcome of lens aspiration, and Fugo blade-assisted capsulotomy and anterior vitrectomy in eyes with anterior persistent hyperplastic primary vitreous (PHPV. Materials and Methods: In this case series, 10 eyes of 10 patients with anterior PHPV underwent lens aspiration. The vascularized posterior capsule was cut with a Fugo blade (plasma knife and removed with a vitrector. A foldable posterior chamber intraocular lens (IOL was implanted in eight eyes and the outcomes were evaluated. Results: The mean age of patients was 16.8 ± 6.37 months (range: 5 to 28 months. The surgery was completed successfully in all eyes. There were no cases of intraocular hemorrhage intraoperatively. Foldable acrylic IOL was implanted in the bag in 3 eyes and in the sulcus in 5 eyes. Two eyes were microphthalmic and did no undergo IOL implantation (aphakic. None of the eyes had a significant reaction or elevated intraocular pressure postoperatively. The follow-up ranged from 4 to 21 months. All the pseudophakic eyes achieved a best corrected visual acuity of ≥20/200 with 50% (4/8 of these eyes with ≥20/60 vision. Conclusion: Lens aspiration followed by posterior capsulotomy with Fugo blade-assisted plasma ablation is a feasible technique for performing successful lens surgery in cases with florid anterior PHPV.

  20. Surgical technique for allogeneic uterus transplantation in macaques

    OpenAIRE

    Hideaki Obara; Iori Kisu; Yojiro Kato; Yohei Yamada; Kentaro Matsubara; Katsura Emoto; Masataka Adachi; Yusuke Matoba; Kiyoko Umene; Yuya Nogami; Kouji Banno; Hideaki Tsuchiya; Iori Itagaki; Ikuo Kawamoto; Takahiro Nakagawa

    2016-01-01

    No study has reported an animal model of uterus transplantation (UTx) using cynomolgus macaques. We aimed to establish a surgical technique of allogeneic UTx assuming the recovery of a uterus from a deceased donor in cynomolgus macaques. Four allogeneic UTxs were performed in female cynomolgus macaques. Donor surgeries comprised en bloc recovery of organs with iliac vessels on both sides, and/or abdominal aorta/vena cava after sufficient perfusion from one femoral artery or external iliac art...

  1. Dual character of interaction between lymphocytes and allogeneic stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, R.V.; Dozmorov, I.M.; Kochetkova, M.O.; Nikolaeva, I.S.

    1986-10-01

    The mechanisms of stimulation of colony formation by small doses of allogeneic lymphocytes were studied in mice. When interaction of lymphocytes with allogeneic stem cells was studied, bone marrow cells of mice were injected into lethally irradiated recipients in the control, and mixtures of bone marrow cells with varied numbers of lymphocytes were injected in the experiment. Dependence of the inactivation indices on the number of lymphocytes injected, based on the results of counting macro- and microcolonies in the spleen, is shown.

  2. Present and future of allogeneic natural killer cell therapy

    Directory of Open Access Journals (Sweden)

    Okjae eLim

    2015-06-01

    Full Text Available Natural killer (NK cells are innate lymphocytes that are capable of eliminating tumor cells and are therefore used for cancer therapy. Although many early investigators used autologous NK cells, including lymphokine-activated killer cells, the clinical efficacies were not satisfactory. Meanwhile, human leukocyte antigen (HLA-haploidentical hematopoietic stem cell transplantation revealed the anti-tumor effect of allogeneic NK cells, and HLA-haploidentical, killer cell immunoglobulin-like receptor (KIR ligand-mismatched allogeneic NK cells are currently used for many protocols requiring NK cells. Moreover, allogeneic NK cells from non-HLA-related healthy donors have been recently used in cancer therapy. The use of allogeneic NK cells from non-HLA-related healthy donors allows the selection of donor NK cells with higher flexibility and to prepare expanded, cryopreserved NK cells for instant administration without delay for ex vivo expansion. In cancer therapy with allogeneic NK cells, optimal matching of donors and recipients is important to maximize the efficacy of the therapy. In this review, we summarize the present state of allogeneic NK cell therapy and its future directions.

  3. LASER INDUCED THERMAL LENS EFFECT

    Institute of Scientific and Technical Information of China (English)

    沈俊; 黄孟才; 江景云; 施教芳

    1991-01-01

    The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal lens measurement.Some opplications of the thermal lens measurement are described.A mode-mismatched dual-beam thermal lens experimental arragement with a modulated probe beam ,designed by the authors.for trace analysis is presented,and its detection limit was found to be 4.1×10-7 for Cu(Ⅱ) in ethanol and 80 mW excitation power.

  4. Lens Epithelial Cell Proliferation and Cell Density in Human Age-related Cataract

    Institute of Scientific and Technical Information of China (English)

    Xialin Liu; Yizhi Liu; Jianliang Zheng; Qiang Huang; Huling Zheng

    2000-01-01

    Purpose: To discuss the potential effect of the lens epithelial cell proliferation in age-related cataract.Methods: In vitro cell proliferation was assayed by MTT method to evaluate the lens epithelial cell density, index, and proliferation capacity in normal lens and all kinds of age-related cataract. Capsulotomy specimens from all kinds of patients who underwent cataract phacoemulsification extraction surgery were compared with the lens epithelial specimens from non-cataract lenses of Eye Bank eyes.Results: Lens epithelial cell density of central anterior capsule (LECD) in female normal lens was higher than that in male, LECD in nuclear cataract( > NⅢ ) was higher than that in normal lens, but in the mature cortical cataract, LF CD was lower. Mitotic index of three kinds of age-related cataracts in vivo had no statistical difference, neither did cell proliferation capacity of cultivated cells in vitro.Conclusion: The individual difference of lens epithelial cell density and proliferation capacity in vivo may be an important underlying cause for senile cataract in the cellular level, especially for nuclear cataract.

  5. The balanced two-string technique for sulcus intraocular lens implantation in the absence of capsular support.

    Science.gov (United States)

    Ibrahim, Hesham A; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  6. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Directory of Open Access Journals (Sweden)

    Hesham A. Ibrahim

    2015-01-01

    Full Text Available Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate (PMMA lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT. Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm. Lens tilt ranged between 1.2° and 2.8° (average 2.17°. Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  7. Physics of electrostatic lens

    Science.gov (United States)

    1981-09-01

    The purpose of this program was to study the physics of the ion-energy boosting electrostatic lens for collective ion acceleration in the Luce diode. Extensive work was done in preparation for experiments on the PI Pulserad 1150. Analytic work was done on the orbit of protons in a mass spectrometer and a copper stack for nuclear activation analysis of proton energy spectrum has been designed. Unfortunately, a parallel program which would provide the Luce diode for the collective ion acceleration experiment never materialized. As a result no experiments were actually performed on the Pulserad 1150.

  8. Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Eijden, R. van; Vries, N.E. de; Cruysberg, L.P.J.; Webers, C.A.; Berenschot, T.; Nuijts, R.M.

    2009-01-01

    A 48-year-old myopic patient with bilateral anterior chamber depth of 3.1 mm and endothelial cell density (ECD) of 2525 cells/mm(2) and 2638 cells/mm(2) preoperatively had bilateral implantation of an Artisan iris-fixated phakic intraocular lens (pIOL). Five years postoperatively, unilateral corneal

  9. Evaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body

    NARCIS (Netherlands)

    Meister, Ulrike; Ohnesorge, Bernhard; Körner, Daniel; Boevé, Michael H

    2014-01-01

    BackgroundSonographic ophthalmic examinations have become increasingly important in veterinary medicine. If the velocity of ultrasound in ocular tissues is known, the A-mode ultrasound method may be used to determine the axial intraocular distances, such as anterior chamber depth, lens thickness,

  10. Evaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body

    NARCIS (Netherlands)

    Meister, Ulrike; Ohnesorge, Bernhard; Körner, Daniel; Boevé, Michael H

    2014-01-01

    BackgroundSonographic ophthalmic examinations have become increasingly important in veterinary medicine. If the velocity of ultrasound in ocular tissues is known, the A-mode ultrasound method may be used to determine the axial intraocular distances, such as anterior chamber depth, lens thickness, ax

  11. Anterior cervical plating

    Directory of Open Access Journals (Sweden)

    Gonugunta V

    2005-01-01

    Full Text Available Although anterior cervical instrumentation was initially used in cervical trauma, because of obvious benefits, indications for its use have been expanded over time to degenerative cases as well as tumor and infection of the cervical spine. Along with a threefold increase in incidence of cervical fusion surgery, implant designs have evolved over the last three decades. Observation of graft subsidence and phenomenon of stress shielding led to the development of the new generation dynamic anterior cervical plating systems. Anterior cervical plating does not conclusively improve clinical outcome of the patients, but certainly enhances the efficacy of autograft and allograft fusion and lessens the rate of pseudoarthrosis and kyphosis after multilevel discectomy and fusions. A review of biomechanics, surgical technique, indications, complications and results of various anterior cervical plating systems is presented here to enable clinicians to select the appropriate construct design.

  12. [Intraocular lens implantation in developmental lens disorders in children].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Kepa, Beata; Chipczyńska, Barbara

    2009-01-01

    The pediatric cataract surgery in eyes with developmental disorders, stay with still considerable challenge. At children, the lasting vision development extorts necessity quick settlement of refraction defect formed after operation. The intraocular lens old boy with cataract in microspherophakia and 12 years old boy with cataract in lens with coloboma. One-piece flexible and rigid PMMA intraocular lens was placed with success at posterior chamber without scleral fixations and without using capsular tension ring in this cases. After 3 years of observation there were no decentration or dislocation of intraocular lens in both children. Authors concluded that in some cases posterior chamber intraocular lens implantation despite defective zonular or capsular support, can make up the effective method of surgical treatment without risk of early dislocation.

  13. Alemtuzumab in allogeneic hematopoetic stem cell transplantation.

    Science.gov (United States)

    Poiré, Xavier; van Besien, Koen

    2011-08-01

    With the use of reduced-intensity conditioning (RIC), early toxicity of allogeneic stem cell transplantation (SCT) has been much reduced. Graft-versus-host disease (GvHD) causes morbidities and mortality. Alemtuzumab is a mAb directed against CD52. When administered prior to transplant, it leads to T-cell depletion. Incorporation of alemtuzumab in RIC results in low rates of GvHD and treatment-related mortality (TRM) in haematological diseases, even in the setting of mismatched-donor transplantation. The use of alemtuzumab for GvHD prophylaxis in SCT. The benefit of alemtuzumab-based conditioning is partially offset by increased disease relapse due to impaired graft-versus-tumor effect (GvT) and by slower immune reconstitution, necessitating special precautions. While GvHD is prevented with alemtuzumab, post-SCT interventions are often required. Most studies find that alemtuzumab-based conditioning results in decreased chronic GvHD and TRM, but also in decreased progression-free survival. Overall survival after 3 - 5 years is usually equivalent and quality of life may be improved because of a lower incidence of sequelae of chronic GvHD. Many aspects of alemtuzumab treatment are under investigation. Alemtuzumab reduces GvHD and TRM after SCT. Use of alemtuzumab requires awareness and strict management of the risk of opportunistic infections and of an increased risk of disease recurrence.

  14. Tetanus after allogeneic bone-marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Kendra, J.R.; Halil, O.; Barrett, A.J.; Selwyn, S. (Westminster Medical School, London (UK))

    1982-11-13

    A brief report is presented of a case of tetanus after allogeneic bone-marrow transplantation complicated by radiation-induced pneumonitis. A 30-year-old army sergeant received a bone-marrow transplant from his brother for the treatment of a granulocytic sarcoma after local radiotherapy to the tumour. Six years earlier he had sustained an open, compound fracture of the left tibia and fibula while on army exercise. At the time a pin and plate had been inserted and booster anti-tetanus administered. Bone-marrow transplantation was performed after total body irradiation. Cyclosporin A was given against graft-versus-host disease. Fifty four days after transplantation tetanus was diagnosed and death followed 14 days later. Necropsy disclosed radiation-induced pneumonitis, but no organisms were cultured from the lungs or the old fracture site. It is suggested that spores were incorporated into the wound site before surgery and that oxygenation around the plate became compromised after transplantation, permitting germination of dormant spores, immunosuppression allowing development of the disease.

  15. Undifferentiated spondyloarthritis following allogeneic stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Espinoza Luis R

    2010-06-01

    Full Text Available Abstract Background Stem cell transplant has been utilized in the treatment of malignancies and rheumatic disease. Rheumatic disease may be transferred from the donor with active disease or may be developed in a recipient de novo as a late complication of SCT. Case Presentation We here report the rare case of a 26-year old male patient, who has been diagnosed with undifferentiated spondyloarthropathy after unique circumstance. The patient suffered from intermittent inflammatory back pain and peripheral joint swelling for several years and did not find relief through multiple emergency room visits at different medical facilities. After a thorough history and physical exam, it was noted that our patient had developed signs of axial disease along with dactylitis and overall that he had been insidiously developing an undifferentiated spondyloarthopathy after allogeneic stem cell transplantation. Conclusion Our observation supports the hypothesis that de novo rheumatic disease can develop after stem cell transplant for a variety of reasons. Thus, larger studies and awareness of this association are needed to delineate the exact underlying mechanism(s.

  16. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  17. claw intraocular lens

    OpenAIRE

    Gonnermann, Johannes

    2015-01-01

    There is a wide range of alternative fixation techniques of intraocular lenses in the absence of adequate capsular support, such as angle- or iris-supported anterior chamber lenses and intra- / transsclerally-fixated (suture, fibrin glue, etc.) and iris-supported posterior chamber lenses. All procedures have different advantages and disadvantages depending on the anatomical situation and integrity of the capsular bag complex and the neighboring structures such as the iris, sclera and corneal ...

  18. Elastic constants of the human lens capsule.

    Science.gov (United States)

    Fisher, R F

    1969-03-01

    1. A technique is described whereby the elasticity of the human lens capsule has been determined at birth and throughout life. This technique requires three separate determinations: (a) thickness; (b) stress and strain; (c) Poisson's ratio; (a) the capsule was clamped between accurately perforated ground glass plates and its thickness determined by noting the change in depth of focus between Latex spherules adhering to its upper and lower surfaces; (b) the undisturbed capsule was then placed in a specially designed glass distension apparatus and the relationship between volume and pressure recorded when it was distended with isotonic saline. The permeability of the capsule was also measured; (c) in some cases Poisson's ratio was determined by measuring the change of thickness of the capsule and the height to which it rose when distended with isotonic saline at different pressures. An apparatus was designed for this purpose.2. The average thickness of the anterior capsule increases from birth until about the 60th year but thereafter it decreases slightly.3. Poisson's ratio was about 0.47 for both cat and human capsule, and no significant variations with age in human capsule could be detected.4. Corrected volume pressure curves obeyed Hook's law almost to the point of capsule rupture.5. In childhood Young's Modulus of elasticity is about 6 x 10(7) dyn/cm(2) and decreases to 3 x 10(7) dyn/cm(2) at 60 and 1.5 x 10(7) dyn/cm(2) in extreme old age.6. The ultimate tensile stress was 2.3 x 10(7) dyn/cm(2) in young capsules and 0.7 x 10(7) dyn/cm(2) in old ones. The maximum percentage elongation was 29 per cent and independent of age.7. The implications of these findings are discussed in relation to(a) the mechanical properties of the lens capsule;(b) the ageing of the lens capsule and basement membranes; and(c) the decrease in elasticity of the lens capsule as a cause of presbyopia.

  19. SURGICAL INTERVENTION AND ACCOMMODATIVE RESPONSES: I. CENTRIPETAL CILIARY BODY, CAPSULE AND LENS MOVEMENT IN RHESUS MONKEYS OF VARYING AGE

    Science.gov (United States)

    Croft, Mary Ann; Mcdonald, Jared P.; James, Rebecca J.; Heatley, Gregg A.; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.

    2009-01-01

    Purpose To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. Methods In 18 rhesus monkey eyes (aged 6–27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal (E–W) nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extra-capsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis. Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Results Centripetal accommodative CP and capsule movement increased in velocity and amplitude post-ECLE compared to pre-ECLE regardless of age (n=5). The presence of the lens substance retarded capsule movement by ~21% in the young eyes and by ~62% in the older eyes. Post-ICLE compared to pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disturbed (n=7), but not in eyes in which the anterior vitreous was left intact (n=2). Following anterior regional zonulolysis (n=4), lens position shifted toward the lysed quadrant during accommodation. Conclusions The presence of the lens substance, capsule zonular attachments, and Wiegers ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce ~6 diopters of accommodation in the presence of a normal young crystalline lens or a similar surrogate. PMID:18552393

  20. The Experimental Study on Implantation of Intraocular Lens in Different Animals

    Institute of Scientific and Technical Information of China (English)

    WANGGui-qin; PENGXiu-jun; GUHan-qing

    2004-01-01

    To prevent the complications in cataract surgeries, the eyes of rabbits and monkeys were implanted with intraocular lens for 360 days. Methods: The eyes of the rabbits were performed with phacoemulsification and soft intraocular lens implantation. The eyes of the monkeys were performed with extracapsular cataract extraction and hard intraocular lens implantation. Results: The postoperative reactions included corneal edema, anterior chamber exudation, posterior capsule opacification and so on. The complications in the eyes of the rabbits were more than that in the eyes of the monkeys. Conclusion: The different postoperative reactions happened in different animals. In clinical the choice of the operative method and intraocular lens depended on the case in order to acquire the best sight.

  1. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  2. Myo/Nog cells: targets for preventing the accumulation of skeletal muscle-like cells in the human lens.

    Directory of Open Access Journals (Sweden)

    Jacquelyn Gerhart

    Full Text Available Posterior capsule opacification (PCO is a vision impairing condition that arises in some patients following cataract surgery. The fibrotic form of PCO is caused by myofibroblasts that may emerge in the lens years after surgery. In the chick embryo lens, myofibroblasts are derived from Myo/Nog cells that are identified by their expression of the skeletal muscle specific transcription factor MyoD, the bone morphogenetic protein inhibitor Noggin, and the epitope recognized by the G8 monoclonal antibody. The goal of this study was to test the hypothesis that depletion of Myo/Nog cells will prevent the accumulation of myofibroblasts in human lens tissue. Myo/Nog cells were present in anterior, equatorial and bow regions of the human lens, cornea and ciliary processes. In anterior lens tissue removed by capsulorhexis, Myo/Nog cells had synthesized myofibroblast and skeletal muscle proteins, including vimentin, MyoD and sarcomeric myosin. Alpha smooth muscle actin (α-SMA was detected in a subpopulation of Myo/Nog cells. Areas of the capsule denuded of epithelial cells were surrounded by Myo/Nog cells. Some of these cell free areas contained a wrinkle in the capsule. Depletion of Myo/Nog cells eliminated cells expressing skeletal muscle proteins in 5-day cultures but did not affect cells immunoreactive for beaded filament proteins that accumulate in differentiating lens epithelial cells. Transforming growth factor-betas 1 and 2 that mediate an epithelial-mesenchymal transition, did not induce the expression of skeletal muscle proteins in lens cells following Myo/Nog cell depletion. This study demonstrates that Myo/Nog cells in anterior lens tissue removed from cataract patients have undergone a partial differentiation to skeletal muscle. Myo/Nog cells appear to be the source of skeletal muscle-like cells in explants of human lens tissue. Targeting Myo/Nog cells with the G8 antibody during cataract surgery may reduce the incidence of PCO.

  3. The Deep Lens Survey

    CERN Document Server

    Wittman, D; Dell'Antonio, I P; Becker, A C; Margoniner, V E; Cohen, J; Norman, D; Loomba, D; Squires, G; Wilson, G; Stubbs, C; Hennawi, J F; Spergel, D N; Boeshaar, P C; Clocchiatti, A; Hamuy, M; Bernstein, G; González, A; Guhathakurta, R; Hu, W; Seljak, U; Zaritsky, D

    2002-01-01

    The Deep Lens Survey (DLS) is a deep BVRz' imaging survey of seven 2x2 degree fields, with all data to be made public. The primary scientific driver is weak gravitational lensing, but the survey is also designed to enable a wide array of other astrophysical investigations. A unique feature of this survey is the search for transient phenomena. We subtract multiple exposures of a field, detect differences, classify, and release transients on the Web within about an hour of observation. Here we summarize the scientific goals of the DLS, field and filter selection, observing techniques and current status, data reduction, data products and release, and transient detections. Finally, we discuss some lessons which might apply to future large surveys such as LSST.

  4. 7.1 T MRI to Assess the Anterior Segment of the Eye

    NARCIS (Netherlands)

    Langner, Soenke; Martin, Heiner; Terwee, Thom; Koopmans, Steven A.; Krueger, Paul C.; Hosten, Norbert; Schmitz, Klaus-Peter; Guthoff, Rudolf F.; Stachs, Oliver

    2010-01-01

    PURPOSE. Visualization of the anterior segment and biometric evaluation of the entire crystalline lens pose significant challenges for imaging techniques because of tissue-induced distortion artifacts. The present study was conducted to demonstrate the advantages of high-resolution magnetic resonanc

  5. 7.1 T MRI to Assess the Anterior Segment of the Eye

    NARCIS (Netherlands)

    Langner, Soenke; Martin, Heiner; Terwee, Thom; Koopmans, Steven A.; Krueger, Paul C.; Hosten, Norbert; Schmitz, Klaus-Peter; Guthoff, Rudolf F.; Stachs, Oliver

    2010-01-01

    PURPOSE. Visualization of the anterior segment and biometric evaluation of the entire crystalline lens pose significant challenges for imaging techniques because of tissue-induced distortion artifacts. The present study was conducted to demonstrate the advantages of high-resolution magnetic resonanc

  6. [Treatment of tibial pseudoarthrosis. Complications after intramedullary, allogeneic fibular grafting].

    Science.gov (United States)

    Helfen, T; Prall, W C; Mutschler, W; Thaller, P H

    2015-04-01

    A 24-year-old woman underwent cosmetic bilateral tibial lengthening with severe complications. In all, 15 operations, including allogeneic fibular grafting of both tibia, were required to treat unstable bilateral non-union, malalignment, and osteomyelitis of the right tibia.The present article describes the surgical strategy of revision to achieve good recovery with full consolidation and proper alignment of the lower leg. Furthermore, the indications for allogeneic bone grafting, which was described by Erich Lexer 100 years ago, are discussed. For surgical revision, a T-external fixator was used on the right leg, while a customized tibial nail was used on the left leg. Using these techniques, full consolidation and proper alignment was achieved. Allogeneic bone grafts in upper extremity defects cannot be recommended.

  7. Loss of AND-34/BCAR3 expression in mice results in rupture of the adult lens

    Science.gov (United States)

    Near, Richard I.; Smith, Richard S.; Toselli, Paul A.; Freddo, Thomas F.; Bloom, Alexander B.; Vanden Borre, Pierre; Seldin, David C.

    2009-01-01

    Purpose AND-34/BCAR3 (Breast Cancer Anti-Estrogen Resistance 3) associates with the focal adhesion adaptor protein, p130CAS/BCAR1. Expression of AND-34 regulates epithelial cell growth pattern, motility, and growth factor dependence. We sought to establish the effects of the loss of AND-34 expression in a mammalian organism. Methods AND-34−/− mice were generated by homologous recombination. Histopathology, in situ hybridization, and western blotting were performed on murine tissues. Results Western analyses confirmed total loss of expression in AND-34−/− splenic lymphocytes. Mice lacking AND-34 are fertile and have normal longevity. While AND-34 is widely expressed in wild type mice, histologic analysis of multiple organs in AND-34−/− mice is unremarkable and analyses of lymphocyte development show no overt changes. A small percentage of AND-34−/− mice show distinctive small white eye lesions resulting from the migration of ruptured cortical lens tissue into the anterior chamber. Following initial vacuolization and liquefaction of the lens cortex first observed at postnatal day three, posterior lens rupture occurs in all AND-34−/− mice, beginning as early as three weeks and seen in all mice at three months. Western blot analysis and in situ hybridization confirmed the presence of AND-34 RNA and protein in lens epithelial cells, particularly at the lens equator. Prior data link AND-34 expression to the activation of Akt signaling. While Akt Ser 473 phosphorylation was readily detectable in AND-34+/+ lens epithelial cells, it was markedly reduced in the AND-34−/− lens epithelium. Basal levels of p130Cas phosphorylation were higher in AND-34+/+ than in AND-34−/− lens epithelium. Conclusions These results demonstrate the loss of AND-34 dysregulates focal adhesion complex signaling in lens epithelial cells and suggest that AND-34-mediated signaling is required for maintenance of the structural integrity of the adult ocular lens. PMID:19365570

  8. Contribution of the gradient refractive index and shape to the crystalline lens spherical aberration and astigmatism.

    Science.gov (United States)

    Birkenfeld, Judith; de Castro, Alberto; Ortiz, Sergio; Pascual, Daniel; Marcos, Susana

    2013-06-28

    The optical properties of the crystalline lens are determined by its shape and refractive index distribution. However, to date, those properties have not been measured together in the same lens, and therefore their relative contributions to optical aberrations are not fully understood. The shape, the optical path difference, and the focal length of ten porcine lenses (age around 6 months) were measured in vitro using Optical Coherence Tomography and laser ray tracing. The 3D Gradient Refractive Index distribution (GRIN) was reconstructed by means of an optimization method based on genetic algorithms. The optimization method searched for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens in 18 different meridians. Spherical aberration and astigmatism of the lenses were estimated using computational ray tracing, with the reconstructed GRIN lens and an equivalent homogeneous refractive index. For all lenses the posterior radius of curvature was systematically steeper than the anterior one, and the conic constant of both the anterior and posterior positive surfaces was positive. In average, the measured focal length increased with increasing pupil diameter, consistent with a crystalline lens negative spherical aberration. The refractive index of nucleus and surface was reconstructed to an average value of 1.427 and 1.364, respectively, for 633 nm. The results of the GRIN reconstruction showed a wide distribution of the index in all lens samples. The GRIN shifted spherical aberration towards negative values when compared to a homogeneous index. A negative spherical aberration with GRIN was found in 8 of the 10 lenses. The presence of GRIN also produced a decrease in the total amount of lens astigmatism in most lenses, while the axis of astigmatism was only little influenced by the presence of GRIN. To our knowledge, this study is the first systematic experimental study of the relative contribution of geometry and GRIN to

  9. Posterior chamber phakic intraocular lens implantation for high myopia

    Directory of Open Access Journals (Sweden)

    Yan Ju

    2013-12-01

    Full Text Available AIM:To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens implantation for the correction of high myopia.METHODS: Retrospective case review of 82 eyes (43 patients undergoing implantable Collamer lens (ICL placement by a single surgeon (Xiao-Wei Gao to correct preoperative mean spherical equivalents between -9.00 diopter (D and -23.00D. Main outcome measures included uncorrected visual acuity (UCVA, refraction, best spectacle-corrected visual acuity (BSCVA, endothelial cell density (ECD, intraocular pressure (IOP, lens transparency, postoperative uveitis. Visante anterior segment optical coherence tomography (AS-OCT was used to measure anterior chamber depth (ACD and the position of ICL.RESULTS:Mean follow-up was 6.54±3.26 months (range 3-12 months. Predictability of the manifest spherical equivalent (SE refraction to within ±1.00D was achieved in 88% of eyes and ±0.50D in 72.5% of eyes. The mean postoperative manifest SE refraction was -1.85±0.72D, with 96.34% of eyes maintaining or gaining ≥1 line(s of BSCVA. The mean 3-month postoperative ECD decreased but had no statistically difference compared with the preoperative ECD. Of the 7 eyes (8.54% with a mild transient increase in intraocular pressure (up to 30mmHg, none required a second surgical procedure or prolonged topical medication. There was no loss of lens transparency. Pigmented precipitates were observed in 5 eyes (6.09%. The mean preoperative ACD measured with AS-OCT was 3.28±0.14mm, three months after surgery, the mean ACD was 2.45±0.22mm. Anterior chamber depth showed a statistically significant reduction. One eye (1.22% had ICL spontaneous rotation, 81 eyes (98.78% of the lens remained correctly centered.CONCLUSION: The implantation of ICL is an effective surgical option for the management of high myopia. But its long time effect and safety still need more time to prove.

  10. Transferring Lens Prescriptions Between Lens-Design Programs

    Science.gov (United States)

    Stacy, John E.; Wooley, Laura; Carlin, Brian

    1989-01-01

    Optical Lens Prescription Data Formatter computer program enables user to transfer complicated lens prescriptions quickly and easily from one major optical-design program to another and back again. One can take advantage of inherent strength of either program. Programs are ACCOS V from Scientific Calculations, Inc., of Fishers, NY, and CODE V from Optical Research Associates of Pasadena, CA. VAX version written in FORTRAN.

  11. Repositioning a decentered intraocular lens with 4 haptics.

    Science.gov (United States)

    Liu, Jiewei; Liu, Wenjie; Jia, Yading; Al-Mohtaseb, Zaina N; Wang, Li

    2016-03-01

    We describe a technique to reposition a decentered 4-haptic intraocular lens (IOL). Using an ophthalmic viscosurgical device, the haptic with the worst distortion is dissected from the capsular bag and pulled outside the bag. The opposite haptic (180 degrees away) is also dissected and placed in front of the anterior capsule. The remaining 2 haptics are left in the capsular bag. With this repositioning, the 2 haptics in the bag limit the IOL movement, the 2 haptics outside the bag are no longer distorted, and the IOL is centered. We present 2 cases in which this technique was used to reposition decentered 4-haptic IOLs.

  12. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  13. Connexin hemichannels in the lens

    Directory of Open Access Journals (Sweden)

    Eric C Beyer

    2014-02-01

    Full Text Available The normal function and survival of cells in the avascular lens is facilitated by intercellular communication through an extensive network of gap junctions formed predominantly by three connexins (Cx43, Cx46, and Cx50. In expression systems, these connexins can all induce hemi-channel currents, but other lens proteins (e.g., pannexin1 can also induce similar currents. Hemichannel currents have been detected in isolated lens fiber cells. These hemichannels may make significant contributions to normal lens physiology and pathophysiology. Studies of some connexin mutants linked to congenital cataracts have implicated hemichannels with aberrant voltage-dependent gating or modulation by divalent cations in disease pathogenesis. Hemichannels may also contribute to age- and disease-related cataracts.

  14. Influence of Transplantation of Allogenic Bone Marrow Mononuclear Cells on the Left Ventricular Remodeling of Rat after Acute Myocardial Infarction

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    To probe into the influence of transplantation of allogenic bone marrow mononuclear cells (BM-MNCs) on the left ventricular remodeling of rat after acute myocardial infarction (AMD,60 male Wistar rats were evenly divided into three groups at random: control group 1, control group 2and transplantation group. In control group 1, chest was opened without ligation of coronary artery;in control group 2 and transplantation group, the left anterior descending branch of coronary artery was ligated to establish AMI model. Prepared culture medium and allogenic BM-MNCs suspension were respectively implanted the surrounding area of infracted cardiac muscle via epicardium of control group 2 and transplantation group. Four weeks after the operation, the osteopontin gene (OPN mRNA, P<0.01), type Ⅰ collagen (P<0.01) and angiotensin Ⅱ (AngⅡ, P<0.01) content in the left ventricular non-infracted myocardium, and the Ang Ⅱ density in blood plasma (P<0.05) of transplantation group and control group 2 were all significantly higher than that of control group 1. In the transplantation group, the myocardial OPN mRNA, type Ⅰ collagen and Ang Ⅱ content of non-infracted zone in left ventricle, and the Ang Ⅱ concentration in blood plasma were all significantly lower than those of control group 2 (P<0.05 for all). It is concluded that allogenic BM-MNCs transplantation may ease left ventricular remodeling after AMI by inhibiting the synthesis of type Ⅰ collagen in the cardiac muscle and down-regulating the expression of Ang Ⅱ and OPN gene.

  15. Allogeneic hematopoietic stem cell transplantation: transfusion issues

    Directory of Open Access Journals (Sweden)

    Akkök ÇA

    2016-05-01

    Full Text Available Çiğdem Akalın Akkök,1,21Department of Immunology and Transfusion Medicine, Oslo University Hospital, Ullevaal, Oslo, Norway; 2Department of Clinical Immunology and Transfusion Medicine, Lund University Hospital, Lund, Sweden Abstract: Allogeneic hematopoietic stem cell transplantation (AHSCT is an intention-to-cure treatment strategy in several malignancies and nonmalignancies. The number of patients receiving AHSCT is increasing due to new indications, and more elderly patients with comorbidities are included in the protocols. Survival of the patients undergoing AHSCT has improved owing to better patient care, including optimization of transfusion support, which has a major contribution. However, transfusion can also be hazardous. Increasing awareness about transfusion and finding the balance between avoiding unnecessary transfusions and transfusing the correct component when needed are the key issues. Myeloablative conditioning results in pancytopenia, and the patients are prone to infections, anemia, and bleeding both before and after transplantation. Until red cell and platelet engraftment, the patients are usually transfusion dependent needing red cell and/or platelet components. Physicians dealing with AHSCT patients should be well informed about the attributes of the blood components they order. Knowledge about transfusion indications, triggers, and how to prevent and manage eventual transfusion complications is also required. The clinical picture can be challenging, and transplantation/treatment-related toxicity/complications can sometimes be difficult to distinguish from a transfusion complication, especially if the latter one took place, for instance, several days or weeks ago. ABO compatibility between the patient and the donor is not a prerequisite when choosing human leukocyte antigen-matched hematopoietic stem cell donor. Consequently, ABO incompatibility exists in ~40% of the cases and brings some immunohematological issues

  16. Gravitational lens surveys with LOFAR

    CERN Document Server

    Wucknitz, O

    2008-01-01

    Deep surveys planned as a Key Science Project of LOFAR provide completely new opportunities for gravitational lens searches. For the first time do large-scale surveys reach the resolution required for a direct selection of lens candidates using morphological criteria. We briefly describe the strategies that we will use to exploit this potential. The long baselines of an international E-LOFAR are essential for this project.

  17. Ascorbate in the ocular lens

    OpenAIRE

    Mody, Vino C. Jr

    2006-01-01

    Purpose: First, we intended to establish a method for sample preparation for measurement of ascorbate in whole rat and guinea pig lenses utilizing ultrafiltration and high performance liquid chromatography with ultraviolet radiation detection. Then, we aimed to investigate whether, in the albino rat, lens ascorbate concentration depends on solid dietary intake. Finally, we investigated if, in the pigmented guinea pig, lens ascorbate concentration may be elevated with drinkin...

  18. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  19. Immunohistochemical observation of anterior subcapsular cataract in eye with spontaneously regressed retinoblastoma.

    Science.gov (United States)

    Shirai, Kumi; Okada, Yuka; Saika, Shizuya

    2010-03-01

    We report the histological findings of secondary cataract in an eye with a spontaneously regressed retinoblastoma to obtain keys to clarify the mechanism of this phenomenon. During phacoemulsification, opacified anterior capsule was obtained, fixed in formalin, and embedded in paraffin. Paraffin sections of the specimen were histologically observed. Hematoxylin-eosin staining showed extracellular matrix accumulation in the extracted fibrous anterior subcapsular opacification. Immunohistochemistry revealed the presence of fibrous collagen types and cellular fibronectin. Presumed lens cells amid matrix were positively labeled for vimentin, alpha-smooth muscle actin, and phospho-Smad2. Histology of the fibrous anterior subcapsular opacification tissue showed the possibility of epithelial-mesenchymal transition of the lens epithelial cells in the secondary cataract following a spontaneously regressed retinoblastoma.

  20. Application of ultrasound biomicro-scopy in the planning of cataract surgery in anterior megalophthalmos

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Zare

    2011-01-01

    Full Text Available Anterior megalophthalmos, a rare hereditary disorder, is macrocornea (horizontal corneal diameter more than 13 mm in association with enlarged lens-iris diaphragm and ciliary ring. One of the major challenging issues in the cataract surgery of these patients is preventing intraocular lens (IOL malposition, because of probable large capsular bag. Several approaches have been selected by previous surgeons, such as, custom-made anterior chamber IOLs. In this study, we show a normal capsular bag diameter despite ciliary ring enlargement, with application of ultrasound biomicroscopy (UMB. We suggest that in cases of anterior megalophthalmos without phacodonesis, UBM could measure the actual size of the capsular bag and obviate the need for further procedures.

  1. Vitreous asteroid hyalosis prolapse into the anterior chamber simulating iris metastasis.

    Science.gov (United States)

    Shields, Carol L; Romanelli-Gobbi, Massi; Lally, Sara E; Shields, Jerry A

    2012-01-01

    Two asymptomatic elderly women who underwent cataract extraction 7 or more years previously and with intraocular lens placement presented with a linear bead-like white multinodular mass in the inferior angle simulating iris metastasis versus large inflammatory precipitates. There was no iris infiltration. In the first case, the posterior lens capsule was intact and there was no evidence of gelatinous vitreous in the anterior chamber, whereas in the second case, the capsule was open and there was gelatinous vitreous prolapse. In both cases, there was asteroid hyalosis in the vitreous. Both patients were diagnosed with prolapsed vitreous asteroid hyalosis into the anterior chamber and managed with observation. Vitreous asteroid hyalosis can prolapse into the anterior chamber of pseudophakic elderly patients with or without capsular opening and can simulate an intraocular tumor.

  2. Vitreous asteroid hyalosis prolapse into the anterior chamber simulating iris metastasis

    Directory of Open Access Journals (Sweden)

    Carol L Shields

    2012-01-01

    Full Text Available Two asymptomatic elderly women who underwent cataract extraction 7 or more years previously and with intraocular lens placement presented with a linear bead-like white multinodular mass in the inferior angle simulating iris metastasis versus large inflammatory precipitates. There was no iris infiltration. In the first case, the posterior lens capsule was intact and there was no evidence of gelatinous vitreous in the anterior chamber, whereas in the second case, the capsule was open and there was gelatinous vitreous prolapse. In both cases, there was asteroid hyalosis in the vitreous. Both patients were diagnosed with prolapsed vitreous asteroid hyalosis into the anterior chamber and managed with observation. Vitreous asteroid hyalosis can prolapse into the anterior chamber of pseudophakic elderly patients with or without capsular opening and can simulate an intraocular tumor.

  3. Evaluation of immersion 20 MHz B-scan ultrasonography in observing lens in the alkali burn eyes

    Institute of Scientific and Technical Information of China (English)

    Qing-Hua; Yang; Bing; Chen; Li-Qiang; Wang; Guang-Hua; Peng; Zhao-Hui; Li; Yi-Fei; Huang

    2014-01-01

    ·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.

  4. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  5. Catarata polar anterior piramidal deslocada para a câmara anterior causando edema de córnea: relato de caso Corneal edema caused by a pyramidal anterior polar cataract dislocated to the anterior chamber: case report

    Directory of Open Access Journals (Sweden)

    Ramon Coral Ghanem

    2004-08-01

    Full Text Available Cataratas polares anteriores piramidais são opacidades cônicas que se projetam para a câmara anterior a partir da cápsula anterior do cristalino. Na grande maioria dos pacientes a opacidade permanece aderida e estável durante toda a vida. O objetivo deste trabalho é documentar uma manifestação incomum desse tipo de catarata: a deiscência espontânea das pirâmides para a câmara anterior causando descompensação endotelial e edema corneal bilateral. Relatamos o caso de uma paciente feminina, de 66 anos, branca, que apresentava edema corneal localizado inferiormente no olho direito associado à lesão nodular branco-esclerótica compatível com a pirâmide anterior da catarata polar. O olho esquerdo apresentava edema corneal difuso intenso e presença de uma catarata polar anterior com a região piramidal deslocada para a câmara anterior. Sabe-se que a pirâmide anterior pode permanecer inabsorvida na câmara anterior por longo período, pois é composta de tecido colágeno denso. Isto causa perda endotelial progressiva e edema corneal e deve ser considerada indicação de remoção cirúrgica da catarata polar anterior e de seu fragmento. Ressalta-se, também, a importância do bom senso no julgamento das cataratas polares anteriores, considerando-se tamanho da opacidade, simetria das opacidades e componente cortical associado, na tentativa de se evitar ambliopia.Pyramidal anterior polar cataracts are conical opacities that project into the anterior chamber from the anterior capsule of the lens. In the vast majority of patients the opacity remains bound and stable throughout life. We report an unusual complication of this type of cataract: spontaneous dehiscence of the pyramids to the anterior chamber causing bilateral endothelial damage and corneal edema. 66-year-old white woman presented with inferior corneal edema in the right eye and diffuse corneal edema in the left eye. A white nodular lesion was observed in the inferior angle

  6. Effect of primary iris and ciliary body cyst on anterior chamber angle in patients with shallow anterior chamber

    Institute of Scientific and Technical Information of China (English)

    Bing-hong WANG; Yu-feng YAO

    2012-01-01

    Objective:To evaluate the prevalence of primary iris and/or ciliary body cysts in eyes with shallow anterior chamber and their effect on the narrowing of the anterior chamber angle.Methods:Among the general physical check-up population,subjects with shallow anterior chambers,as judged by van Herick technique,were recruited for further investigation.Ultrasound biomicroscope (UBM) was used to detect and measure the cysts located in the iris and/or ciliary body,the anterior chamber depth (ACD),the angle opening distance at 500 μm (AOD500),and the trabecular-iris angle (TIA).A-scan ultrasonography was used to measure the ocular biometry,including lens thickness,axial length,lens/axial length factor (LAF),and relative lens position (RLP).The effect of the cyst on narrowing the corresponding anterior chamber angle and the entire angle was evaluated by the UBM images,ocular biometry,and gonioscopic grading.The eye with unilateral cyst was compared with the eye without the cyst for further analysis.Results:Among the 727 subjects with shallow anterior chamber,primary iris and ciliary body cysts were detected in 250 (34.4%) patients; among them 96 (38.4%) patients showed unilateral single cyst,21 (8.4%) patients had unilateral double cysts,and 42 (16.8%) patients manifested unilateral multiple and multi-quadrants cysts.Plateau iris configuration was found in 140 of 361 (38.8%) eyes with cysts.The mean size of total cysts was (0.6547±0.2319) mm.In evaluation of the effect of the cyst size and location on narrowing the corresponding angle to their position,the proportion of the cysts causing corresponding angle narrowing or closure among the cysts larger than 0.8 mm (113/121,93.4%) was found to be significantly higher than that of the cysts smaller than 0.8 mm (373/801,46.6%),and a significant higher proportion was also found in the cysts located at iridociliary sulcus (354/437,81.0%) than in that at the pars plicata (131/484,27.1%).In evaluating the effect

  7. Increased rejection of murine allogeneic bone marrow in presensitized recipients

    NARCIS (Netherlands)

    vanOs, R; deWitte, T; Dillingh, JH; Mauch, PM; Down, JD

    1997-01-01

    The role of presensitizing murine recipients with donor spleen cells prior to T cell-depleted or -repleted H-2 compatible allogeneic bone marrow transplantation (BMT) was investigated at two different doses of total body irradiation (TBI). Recipients that were presensitized with 2 x 10(7) irradiated

  8. Soluble urokinase plasminogen activator receptor during allogeneic stem cell transplantation

    DEFF Research Database (Denmark)

    Haastrup, E; Andersen, J; Ostrowski, S R

    2011-01-01

    the course of allogeneic stem cell transplantation (SCT). Twenty SCT patients were included in the study. suPAR was measured by ELISA in daily taken plasma samples during the pretransplant conditioning with chemotherapy and weekly for 1 month after infusion of the graft. suPAR levels before the start...

  9. First report on fertility after allogeneic uterus transplantation.

    Science.gov (United States)

    Díaz-García, César; Akhi, Shamima N; Wallin, Ann; Pellicer, Antonio; Brännström, Mats

    2010-11-01

    Uterus transplantation may become the first available treatment for uterine factor infertility, which is due to the absence or malfunction of the uterus. Here we describe for the first time pregnancy after allogeneic uterus transplantation, as a proof of concept of uterine function in a transplanted uterus in a standardized animal model (rat) under immunosuppression.

  10. Toll-like receptor polymorphisms in allogeneic hematopoietic cell transplantation

    DEFF Research Database (Denmark)

    Kornblit, Brian; Enevold, Christian; Wang, Tao;

    2014-01-01

    To assess the impact of the genetic variation in toll-like receptors (TLRs) on outcome after allogeneic myeloablative conditioning hematopoietic cell transplantation (HCT), we investigated 29 single nucleotide polymorphisms across 10 TLRs in 816 patients and donors. Only donor genotype of TLR8 rs...

  11. Sinusitis in patients undergoing allogeneic bone marrow transplantation - a review.

    Science.gov (United States)

    Drozd-Sokolowska, Joanna Ewa; Sokolowski, Jacek; Wiktor-Jedrzejczak, Wieslaw; Niemczyk, Kazimierz

    Sinusitis is a common morbidity in general population, however little is known about its occurrence in severely immunocompromised patients undergoing allogeneic hematopoietic stem cell transplantation. The aim of the study was to analyze the literature concerning sinusitis in patients undergoing allogeneic bone marrow transplantation. An electronic database search was performed with the objective of identifying all original trials examining sinusitis in allogeneic hematopoietic stem cell transplant recipients. The search was limited to English-language publications. Twenty five studies, published between 1985 and 2015 were identified, none of them being a randomized clinical trial. They reported on 31-955 patients, discussing different issues i.e. value of pretransplant sinonasal evaluation and its impact on post-transplant morbidity and mortality, treatment, risk factors analysis. Results from analyzed studies yielded inconsistent results. Nevertheless, some recommendations for good practice could be made. First, it seems advisable to screen all patients undergoing allogeneic hematopoietic stem cell transplantation with Computed Tomography (CT) prior to procedure. Second, patients with symptoms of sinusitis should be treated before hematopoietic stem cell transplantation (HSCT), preferably with conservative medical approach. Third, patients who have undergone hematopoietic stem cell transplantation should be monitored closely for sinusitis, especially in the early period after transplantation. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  12. Epigenetic therapy in allogeneic hematopoietic stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Qaiser Bashir

    2013-01-01

    Full Text Available DNA methylation and other epigenetic phenomena appear to be relevant in the pathogenesis of several malignant disorders. DNA methyltransferases add methyl groups to cytosine-phosphate-guanine (CpG islandsleading to gene promoter silencing. The DNA methyltransferases inhibitors azacitidine and decitabine have anti-tumor activity against a broad range of malignancies, but have been investigated mostly in myelodysplastic syndrome. In addition, these agents have immunomodulatory effects that are under investigation in the allogeneic stem cell transplantation scenario. Both drugs have been used in the perioperative period of allogeneic transplantations with varying degrees of success. It has been hypothesized that low dose azacitidine may increase the graftversus-leukemia effect and have a role in the maintenance of remission after allogeneic transplantation for myeloid leukemias. It is also intriguing that this favorable effect might occur while mitigating graft-versus-host disease. Here we present a review of the rapidly growing field of epigenetic manipulation using hypomethylating agents in allogeneic transplantation.

  13. Evaluation of Anterior Segment's Structures in Tilted Disc Syndrome

    Science.gov (United States)

    Ozsoy, Ercan; Demirel, Ersin Ersan; Cumurcu, Tongabay

    2016-01-01

    Purpose. To evaluate anterior segment's structures by Pentacam in patients with tilted disc syndrome (TDS). Methods. Group 1 included forty-six eyes of forty-six patients who have the TDS. Group 2 including forty-six eyes of forty-six cases was the control group which was equal to the study group in age, gender, and refraction. A complete ophthalmic examination was performed in both groups. All cases were evaluated by Pentacam. The axial length (AL) of eyes was measured by ultrasound. Quantitative data obtained from these measurements were compared between two groups. Results. There was no statistically significant difference for age, gender, axial length, and spherical equivalent measurements between two groups (p = 0.625, p = 0.830, p = 0.234, and p = 0.850). There was a statistically significant difference for central corneal thickness (CCT), corneal volume (CV), anterior chamber angle (ACA), and pupil size measurements between two groups (p = 0.001, p = 0.0001, p = 0.003, and p = 0.001). Also, there was no statistically significant difference for anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness (LT) measurements between two groups (p = 0.130, p = 0.910, and p = 0.057). Conclusion. We determined that CCT was thinner, CV was less, and ACA was narrower in patients with TDS. There are some changes in the anterior segment of the eyes with tilted disc. PMID:27648303

  14. Anterior crucate ligament (ACL) injury

    Science.gov (United States)

    ... An anterior cruciate ligament injury is the over-stretching or tearing of the anterior cruciate ligament (ACL) ... may be injured. This is a medical emergency. Prevention Use proper techniques when playing sports or exercising. ...

  15. The 2010 IODC lens design problem: the green lens

    Science.gov (United States)

    Juergens, Richard C.

    2010-08-01

    The lens design problem for the 2010 IODC is to design a 100 mm focal length lens in which every optical surface has the same radius of curvature, positive or negative, or is plano. The lens is used monochromatically at 532 nm and is made of only Schott N-BK7 glass. The goal of the problem is to maximize the product of the semi-field of view and the entrance pupil diameter while holding the distortion to within +/-5% and the RMS wavefront error to <= 0.07 wave within the field of view. There were 37 entries from eight different countries. Four different commercial lens design programs were used, along with two custom, in-house programs. The number of lens elements in the entries ranged from 3 to 64. The overall length of the lenses varied from 105 mm to 3.6 km. The winning entry had an entrance pupil diameter of 81.3 mm and a semi-field of view of 43.5° for a merit function product of 3537.

  16. Facetas em dentes anteriores

    OpenAIRE

    Veloso, Helena Rafaela Lourenço Martins

    2015-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária A presente revisão bibliográfica aborda as facetas estéticas em dentes anteriores, pela crescente valorização de um sorriso esteticamente agradável, facto que faz com que as pessoas procurem cada vez mais alternativas de tratamento para melhorar a aparência do seu sorriso. Os dentes anteriores são decisivos na aparência estética e, c...

  17. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  18. Intradural anterior transpetrosal approach.

    Science.gov (United States)

    Ichimura, Shinya; Hori, Satoshi; Hecht, Nils; Czabanka, Marcus; Vajkoczy, Peter

    2016-10-01

    The standard anterior transpetrosal approach (ATPA) for petroclival lesions is fundamentally an epidural approach and has been practiced for many decades quite successfully. However, this approach has some disadvantages, such as epidural venous bleeding around foramen ovale. We describe here our experience with a modified technique for anterior petrosectomy via an intradural approach that overcomes these disadvantages. Five patients with petroclival lesions underwent surgery via the intradural ATPA. The intraoperative hallmarks are detailed, and surgical results are reported. Total removal of the lesions was achieved in two patients with petroclival meningioma and two patients with pontine cavernoma, whereas subtotal removal was achieved in one patient with petroclival meningioma without significant morbidity. No patient experienced cerebrospinal fluid leakage. The intradural approach is allowed to tailor the extent of anterior petrosectomy to the individually required exposure, and the surgical procedure appeared to be more straightforward than via the epidural route. Caveats encountered with the approach were the temporal basal veins that could be spared as well as identification of the petrous apex due to the lack of familial epidural landmarks. The risk of injury to the temporal bridging veins is higher in this approach than in the epidural approach. Intradural approach is recommended in patients with a large epidural venous route, such as sphenobasal and sphenopetrosal vein. Navigation via bone-window computed tomography is useful to identify the petrous apex.

  19. A medieval fallacy: the crystalline lens in the center of the eye

    Directory of Open Access Journals (Sweden)

    Leffler CT

    2016-04-01

    Full Text Available Christopher T Leffler,1 Tamer M Hadi,2 Akrithi Udupa,1 Stephen G Schwartz,3 Daniel Schwartz1 1Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, 2Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, TN, 3Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Objective: To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Background: Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Methods: Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Results: Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3–5.3 mm. Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Conclusion: Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly

  20. Antioxidant status of dog aqueous humor after extracapsular lens extraction

    Directory of Open Access Journals (Sweden)

    Barros P.S.M.

    2003-01-01

    Full Text Available We determined the antioxidant status of the aqueous humor after extracapsular lens extraction in 14 mongrel dogs weighing about 10 kg. The animals were examined by slit lamp biomicroscopy, applanation tonometry and indirect ophthalmoscopy. One eye was submitted to conventional extracapsular lens extraction and the other was used as control. Samples of aqueous humor were obtained by anterior chamber paracentesis before and at days 1, 2, 3, 7 and 15 after surgery. Total antioxidant status was determined as the capacity of aqueous humor to inhibit free radical generation by 2,2-azobis(2-amidopropane chlorine. Ascorbic acid concentration was measured by HPLC with UV detection. Protein content was determined with the biuret reagent. Statistical analysis was performed by ANOVA followed by the Tukey-Kramer test. Protein concentration increased from 0.61 to 22 mg/ml 24 h after surgery. These levels were maintained and returned to normal at day 7. Total antioxidant capacity was reduced from 50 to about 30 min until day 3 and at day 7 it was equal to control. Ascorbic acid levels were reduced from 252 to about 110 µM and then returned to control values at day 15. Considering the importance of ascorbic acid concentration in aqueous humor for the maintenance of the antioxidant status of the anterior segment of the eye, the decrease of antioxidant defenses suggests that the surgical procedures promote an oxidative stress condition in the eye.

  1. Repeatability of OCT lens thickness measures with age and accommodation.

    Science.gov (United States)

    Doyle, Lesley; Little, Julie-Anne; Saunders, Kathryn J

    2013-12-01

    To investigate crystalline lens thickness (LT) across a range of ages and accommodative demands and to evaluate the repeatability of LT measurements using the Visante Anterior Segment Optical Coherence Tomographer (AS-OCT) (Zeiss Meditec, Germany) under non-cycloplegic conditions. Participants were 98 visually normal adults aged 18-75 years, stratified into age groups of 18-29, 30-39, 40-49, 50-59, and 60-75 years of age. Images of the crystalline lens were taken using the Visante AS-OCT during stimulation of accommodation at demands of 0, 1, 2, 3, 4, 5, and 8 D with accommodative response measured in a subgroup of participants. Images were analyzed and LT measured assuming a refractive index of 1.42. Repeat measures were taken from 86 participants for each accommodative demand at a second visit. The mean unaccommodated LT for all participants was 4.07 ± 0.40 mm. An average increase in LT of 20 μm per year was calculated (linear regression, R² = 0.61, F(1,89) = 143.92, p report the repeatability of LT measures using the Visante AS-OCT in the non-cyclopleged eye. It has also demonstrated the ability of the Visante AS-OCT to detect small changes in lens thickness with accommodation.

  2. Posterior chamber phakic intraocular lens implantation for high myopia

    Institute of Scientific and Technical Information of China (English)

    沈晔; 杜持新; 顾扬顺; 王竞

    2003-01-01

    Objective To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia.Methods Thirty-nine eyes of twenty patients with high myopia (between-11.75 and-25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6-48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP), corneal reaction and space between crystal lens and intraocular lens (IOLs) were tested.Results Successful implantation was achieved in all patients. Visual acuity without correction greater than 0.5 was found in 34 eyes at 1 day and 3 months postoperatively. Thirty-five eyes maintained a low negative power of refraction (-1.42±1.32 doipters), which did not prevent the patients from most of their daily activities. During 3-48 months' follow-up, refraction was stable and no cornea edema and glaucoma was found. Two eyes of one patient had corticosteroid glaucoma and another eye showed cataractogenesis under anterior capsular membrane.Conclusion Posterior chamber PIOL implantation is predictable, safe, and effective in the correction of high myopia, and its indications should be carefully selected.

  3. Romiplostim in thrombocytopenia treatment after allogeneic bone marrow transplantation

    Directory of Open Access Journals (Sweden)

    I. A. Lisukov

    2014-07-01

    Full Text Available Persistent thrombocytopenia is a frequent complication after allogeneic bone marrow transplantation (BMT. The major causes of thrombocytopenia include accelerated platelet destruction by antiplatelet antibodies, microangiopathy, viral infection, drug toxicity,graft`s hypofunction with insufficient production of platelets from megakaryocytes. We have evaluated an efficacy of TPO-receptor agonistromiplostim in treatment of 3 patients with refractory thrombocytopenia after allogeneic BMT. The first 30 years old patient received haploidentical allogeneic stem cell transplantation for refractory AML relapse. He developed graft hypofunction due to CMV infection, acute GVHD and thrombotic thrombocytopenic purpura (TTP with platelet counts 5 × 109/l and bleeding complications. After bone marrow “boost” the patient received romiplostim 1 mkg/kg weekly during 2 weeks and 4 mkg/kg during another 2 weeks. Upon reaching platelet counts 50 × 109/l the romiplostim was stopped, but platelet count decreased to 5–7 × 109/l and romiplostim was administered in dose of 4 mkg/kg weekly during 5 weeks. Platelet counts have achieved 150 × 109/l and thrombocytopenia during further follow-up was not revealed. The second 19 years old AML patient received haploidentical allogeneic stem cell transplantation for second remission consolidation. He developed thrombocytopenia (10 × 109/l due to CMV infection and severe TTP. He received romiplostim 4 mkg/kg weekly and 5 weeks later platelet counts was 50 × 109/l. The administration of romiplostim was allowed to avoid bleeding complications and transfusion dependency. The third 18 years old ALL patient received MUD allogeneic stem cell transplantation for second remission consolidation. He developed profound thrombocytopenia (5 × 109/l with severe hemorrhagic complications and platelet transfusions refractory due to TTP and acute GVHD. He received one dose of romiplostim 1 mkg/kg and two doses of 3 mkg

  4. Romiplostim in thrombocytopenia treatment after allogeneic bone marrow transplantation

    Directory of Open Access Journals (Sweden)

    I. A. Lisukov

    2012-01-01

    Full Text Available Persistent thrombocytopenia is a frequent complication after allogeneic bone marrow transplantation (BMT. The major causes of thrombocytopenia include accelerated platelet destruction by antiplatelet antibodies, microangiopathy, viral infection, drug toxicity,graft`s hypofunction with insufficient production of platelets from megakaryocytes. We have evaluated an efficacy of TPO-receptor agonistromiplostim in treatment of 3 patients with refractory thrombocytopenia after allogeneic BMT. The first 30 years old patient received haploidentical allogeneic stem cell transplantation for refractory AML relapse. He developed graft hypofunction due to CMV infection, acute GVHD and thrombotic thrombocytopenic purpura (TTP with platelet counts 5 × 109/l and bleeding complications. After bone marrow “boost” the patient received romiplostim 1 mkg/kg weekly during 2 weeks and 4 mkg/kg during another 2 weeks. Upon reaching platelet counts 50 × 109/l the romiplostim was stopped, but platelet count decreased to 5–7 × 109/l and romiplostim was administered in dose of 4 mkg/kg weekly during 5 weeks. Platelet counts have achieved 150 × 109/l and thrombocytopenia during further follow-up was not revealed. The second 19 years old AML patient received haploidentical allogeneic stem cell transplantation for second remission consolidation. He developed thrombocytopenia (10 × 109/l due to CMV infection and severe TTP. He received romiplostim 4 mkg/kg weekly and 5 weeks later platelet counts was 50 × 109/l. The administration of romiplostim was allowed to avoid bleeding complications and transfusion dependency. The third 18 years old ALL patient received MUD allogeneic stem cell transplantation for second remission consolidation. He developed profound thrombocytopenia (5 × 109/l with severe hemorrhagic complications and platelet transfusions refractory due to TTP and acute GVHD. He received one dose of romiplostim 1 mkg/kg and two doses of 3 mkg

  5. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  6. International rigid contact lens prescribing.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B; Helland, Magne; Itoi, Motozumi; Jones, Deborah; Nichols, Jason J; van der Worp, Eef; Woods, Craig A

    2010-06-01

    Rigid lenses have been fitted less since the introduction of soft lenses nearly 40 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 facilitate an accurate characterization of the pattern of the decline of rigid lens fitting during the first decade of this century. There is a trend for rigid lenses to be utilized primarily for refitting those patients who are already successful rigid lens wearers-most typically older females being refit with higher Dk materials. Rigid lenses are generally fitted on a full-time basis (four or more days of wear per week) without a planned replacement schedule. Orthokeratology is especially popular in the Netherlands, but is seldom prescribed in the other countries surveyed.

  7. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  8. Planar immersion lens with metasurfaces

    CERN Document Server

    Ho, John S; Tanabe, Yuji; Yeh, Alexander J; Fan, Shanhui; Poon, Ada S Y

    2015-01-01

    The solid immersion lens is a powerful optical tool that allows light entering material from air or vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, they rely on semispherical topographies and are non-planar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referred to as metasurfaces, to construct flat optical components for manipulating light in unusual ways. Here, we propose and demonstrate the concept of a planar immersion lens based on metasurfaces. The resulting planar device, when placed near an interface between air and dielectric material, can focus electromagnetic radiation incident from air to a spot in material smaller than the free-space wavelength. As an experimental demonstration, we fabricate an ultrathin and flexible microwave lens and further show that it achieves wireless energy transfer in material mimicking biological tissue.

  9. Algebraic Lens Distortion Model Estimation

    Directory of Open Access Journals (Sweden)

    Luis Alvarez

    2010-07-01

    Full Text Available A very important property of the usual pinhole model for camera projection is that 3D lines in the scene are projected to 2D lines. Unfortunately, wide-angle lenses (specially low-cost lenses may introduce a strong barrel distortion, which makes the usual pinhole model fail. Lens distortion models try to correct such distortion. We propose an algebraic approach to the estimation of the lens distortion parameters based on the rectification of lines in the image. Using the proposed method, the lens distortion parameters are obtained by minimizing a 4 total-degree polynomial in several variables. We perform numerical experiments using calibration patterns and real scenes to show the performance of the proposed method.

  10. Anterior knee pain

    Energy Technology Data Exchange (ETDEWEB)

    LLopis, Eva [Hospital de la Ribera, Alzira, Valencia (Spain) and Carretera de Corbera km 1, 46600 Alzira Valencia (Spain)]. E-mail: ellopis@hospital-ribera.com; Padron, Mario [Clinica Cemtro, Ventisquero de la Condesa no. 42, 28035 Madrid (Spain)]. E-mail: mario.padron@clinicacemtro.com

    2007-04-15

    Anterior knee pain is a common complain in all ages athletes. It may be caused by a large variety of injuries. There is a continuum of diagnoses and most of the disorders are closely related. Repeated minor trauma and overuse play an important role for the development of lesions in Hoffa's pad, extensor mechanism, lateral and medial restrain structures or cartilage surface, however usually an increase or change of activity is referred. Although the direct relation of cartilage lesions, especially chondral, and pain is a subject of debate these lesions may be responsible of early osteoarthrosis and can determine athlete's prognosis. The anatomy and biomechanics of patellofemoral joint is complex and symptoms are often unspecific. Transient patellar dislocation has MR distinct features that provide evidence of prior dislocation and rules our complication. However, anterior knee pain more often is related to overuse and repeated minor trauma. Patella and quadriceps tendon have been also implicated in anterior knee pain, as well as lateral or medial restraint structures and Hoffa's pad. US and MR are excellent tools for the diagnosis of superficial tendons, the advantage of MR is that permits to rule out other sources of intraarticular derangements. Due to the complex anatomy and biomechanic of patellofemoral joint maltracking is not fully understood; plain films and CT allow the study of malalignment, new CT and MR kinematic studies have promising results but further studies are needed. Our purpose here is to describe how imaging techniques can be helpful in precisely defining the origin of the patient's complaint and thus improve understanding and management of these injuries.

  11. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  12. ELECTRON MICROSCOPY STUDIES OF LENS FROM TWO CASES OF OCULAR SIDEROSIS

    Institute of Scientific and Technical Information of China (English)

    1991-01-01

    Cases report Case 1: A 50-year-old man was injuried by iron filings on his left eye. He was admitted to our hospital on Feb. 3, 1987. On examination, his visual acuity was 20/15 OD and 20/500 OS. Left eye: The cornea was clear, the anterior chamber depth was 3 CT, tyndall(-). Iris pattern is clear, pupil was 3.5×3.5mm. Dilated pupil examination: There were scattered brown-yellow ironrust under anterior capsule and the lens cortex had become totally opaque. Nuclear, posterior capsule and fundus can't be ...

  13. The anterior cingulate cortex

    Directory of Open Access Journals (Sweden)

    Pavlović D.M.

    2009-01-01

    Full Text Available The anterior cingulate cortex (ACC has a role in attention, analysis of sensory information, error recognition, problem solving, detection of novelty, behavior, emotions, social relations, cognitive control, and regulation of visceral functions. This area is active whenever the individual feels some emotions, solves a problem, or analyzes the pros and cons of an action (if it is a right decision. Analogous areas are also found in higher mammals, especially whales, and they contain spindle neurons that enable complex social interactions. Disturbance of ACC activity is found in dementias, schizophrenia, depression, the obsessive-compulsive syndrome, and other neuropsychiatric diseases.

  14. Ready-made allogeneic ABO-specific serum eye drops

    DEFF Research Database (Denmark)

    Harritshøj, Lene Holm; Nielsen, Connie; Ullum, Henrik

    2014-01-01

    , registered and stored at -30°C in the blood bank. Upon request, frozen ABO-identical serum drops in lots of 14 bottles could be provided immediately. Safety and efficacy were evaluated in 34 patients with severe ocular surface disease refractory to conventional medical therapy. Patients were treated six...... serum treatment. CONCLUSION: Ready-made ABO-identical allogeneic serum eye drops were straightforwardly produced, quality-assured and registered as a safe standard blood product for the treatment of certain cases of severe dry eye disease. Therapeutic efficacy was comparable to previous reports......PURPOSE: To overcome problems and delays of the preparation of autologous serum eye drops, a production line of ABO-specific allogeneic serum eye drops from male blood donors was set up in a blood bank. Feasibility, clinical routine, safety and efficacy were evaluated in a cohort of patients...

  15. Panoramic lens designed with transformation optics

    Science.gov (United States)

    Wang, Huaping; Deng, Yangyang; Zheng, Bin; Li, Rujiang; Jiang, Yuyu; Dehdashti, Shahram; Xu, Zhiwei; Chen, Hongsheng

    2017-01-01

    The panoramic lens is a special kind of lens, which is applied to observe full view. In this letter, we theoretically present a panoramic lens (PL) using transformation optics method. The lens is designed with inhomogeneous and anisotropic constitutive parameters, which has the ability to gather light from all directions and confine light within the visual angle of observer. Simulation results validate our theoretical design.

  16. SimpLens: Interactive gravitational lensing simulator

    Science.gov (United States)

    Saha, Prasenjit; Williams, Liliya L. R.

    2016-06-01

    SimpLens illustrates some of the theoretical ideas important in gravitational lensing in an interactive way. After setting parameters for elliptical mass distribution and external mass, SimpLens displays the mass profile and source position, the lens potential and image locations, and indicate the image magnifications and contours of virtual light-travel time. A lens profile can be made shallower or steeper with little change in the image positions and with only total magnification affected.

  17. Allogeneic stem cell transplantation in acute myeloid leukemia

    Directory of Open Access Journals (Sweden)

    Natasha Ali

    2012-11-01

    Full Text Available We report a case series of 12 patients with acute myeloid leukemia who underwent allogeneic stem cell transplant with a matched related donor. Male to female ratio was 1:1. The main complication post-transplant was graft-versus-host disease (n=7 patients. Transplant-related mortality involved one patient; cause of death was multi-organ failure. After a median follow up of 36.0±11.3 months, overall survival was 16%.

  18. Leukemia in donor cells after allogeneic hematopoietic stem cell transplant

    OpenAIRE

    2002-01-01

    The development of leukemia in donor cells after allogeneic hematopoietic stem cell transplant is an extremely rare event. We report here the case of a patient who developed myelodysplastic syndrome/acute myeloid leukemia, in cells of donor origin 3.5 years after related donor HSCT for refractory chronic lymphocytic leukemia and therapy-induced myelodysplastic syndrome. The origin of the leukemia was determined by analysis of minisatillite polymorphism tested on CD34(+) cells.

  19. Financial burden in recipients of allogeneic hematopoietic cell transplantation.

    Science.gov (United States)

    Khera, Nandita; Chang, Yu-hui; Hashmi, Shahrukh; Slack, James; Beebe, Timothy; Roy, Vivek; Noel, Pierre; Fauble, Veena; Sproat, Lisa; Tilburt, Jon; Leis, Jose F; Mikhael, Joseph

    2014-09-01

    Although allogeneic hematopoietic cell transplantation (HCT) is an expensive treatment for hematological disorders, little is known about the financial consequences for the patients who undergo this procedure. We analyzed factors associated with its financial burden and its impact on health behaviors of allogeneic HCT recipients. A questionnaire was retrospectively mailed to 482 patients who underwent allogeneic HCT from January 2006 to June 2012 at the Mayo Clinic, to collect information regarding current financial concerns, household income, employment, insurance, out-of-pocket expenses, and health and functional status. A multivariable logistic regression analysis identified factors associated with financial burden and treatment nonadherence. Of the 268 respondents (56% response rate), 73% reported that their sickness had hurt them financially. All patients for whom the insurance information was available (missing, n = 13) were insured. Forty-seven percent of respondents experienced financial burden, such as household income decreased by >50%, selling/mortgaging home, or withdrawing money from retirement accounts. Three percent declared bankruptcy. Younger age and poor current mental and physical functioning increased the likelihood of financial burden. Thirty-five percent of patients reported deleterious health behaviors because of financial constraints. These patients were likely to be younger, have lower education, and with a longer time since HCT. Being employed decreased the likelihood of experiencing financial burden and treatment nonadherence due to concern about costs. A significant proportion of allogeneic HCT survivors experience financial hardship despite insurance coverage. Future research should investigate potential interventions to help at-risk patients and prevent adverse financial outcomes after this life-saving procedure. Copyright © 2014 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  20. IMPLANTABLE COLLAMER LENS IMPLANTATION AND IRIS CERCLAGE FOR THE TREATMENT OF URRETS-ZAVALIA SYNDROME

    Directory of Open Access Journals (Sweden)

    Arnaldo D Santos

    2013-10-01

    Full Text Available A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic IOL implantation in her left eye (LE under local anesthesia, without intraoperative complications. The preoperative slitlamp examination was normal and she had no past medical history. On the second day post-operatory, she developed fixed dilated mydriasis and one month later we documented IOL subluxation. There had been no history of intra-ocular hypertension and no mydriatic drops were used. Diagnosis of Urrets-Zavalia syndrome was established. We removed the IOL and observed for six months after adapting coloured contact lens. During this time she complained about glare, photophobia and developed contact lens intolerance. We decided to implant a posterior chamber Implantable Collamer Lens (ICL and to perform iris cerclage in the LE, with good aesthetic and refractive outcome. Posterior chamber ICL implantation with iris cerclage seems to be a simple and effective approach to this situation.

  1. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Science.gov (United States)

    Jordana, M Isabel Canut; Formigó, Daniel Pérez; González, Rodrigo Abreu; Reus, Jeroni Nadal

    2010-01-01

    Aims We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Methods Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Results Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Conclusion Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively. PMID:21151331

  2. [Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].

    Science.gov (United States)

    Handzel, D M

    2012-04-01

    This report concerns the case of a 67-year-old male patient who underwent uncomplicated phacoemulsification with implantation of a posterior chamber intraocular lens (IOL). After an interval of 2 months the patient developed iritis together with an uncontrollable increase in intraocular pressure. After a detailed examination a dislocated haptic of the IOL was identified as the cause of the symptoms. The dislocation had led to uveitis-glaucoma-hyphema syndrome although no hemorrhage was observed. In addition to this complication the haptic had arroded the zonular complex which made implantation of an anterior chamber lens necessary. Although improvements in operating techniques, lens materials and designs have been made uveitis-glaucoma-hyphema syndrome has to be kept in mind. Surgical intervention is the only therapeutic option.

  3. New Management of Malignant Glaucoma by Phacoemulsification with Posterior Chamber Foldable Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    GeJian; GuoY

    1999-01-01

    Objective:To investigate the feasibility of phacoemulsification with posterior chamber foldable intraocular lens implantation in the management of malignant glaucoma. Patients and Methods:Fourteen patients with malignant glaucoma diagnosed in the Department of Glaucoma were enrolled in the study.12 patients developed malignant glaucoma after filtration surgery.1 developed after peripheral iridectomy.1 patient developed malignant glaucoma without any clear cause.Cataract phacoemulsification was performed.Posterior chamber intraocular foldable lens was implanted in 10 cases of patients.Results:All 14 patients were cured wiht normal intraocular pressure,normal anterior chamber depth and increased visual acuity.Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation is a good alternative in treating malignant glaucoma.

  4. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  5. Inverse modeling approach to allogenic karst system characterization.

    Science.gov (United States)

    Dörfliger, N; Fleury, P; Ladouche, B

    2009-01-01

    Allogenic karst systems function in a particular way that is influenced by the type of water infiltrating through river water losses, by karstification processes, and by water quality. Management of this system requires a good knowledge of its structure and functioning, for which a new methodology based on an inverse modeling approach appears to be well suited. This approach requires both spring and river inflow discharge measurements and a continuous record of chemical parameters in the river and at the spring. The inverse model calculates unit hydrographs and the impulse responses of fluxes from rainfall hydraulic head at the spring or rainfall flux data, the purpose of which is hydrograph separation. Hydrograph reconstruction is done using rainfall and river inflow data as model input and enables definition at each time step of the ratio of each component. Using chemical data, representing event and pre-event water, as input, it is possible to determine the origin of spring water (either fast flow through the epikarstic zone or slow flow through the saturated zone). This study made it possible to improve a conceptual model of allogenic karst system functioning. The methodology is used to study the Bas-Agly and the Cent Font karst systems, two allogenic karst systems in Southern France.

  6. Altered Allogeneic Immune Responses in Middle-Aged Mice

    Institute of Scientific and Technical Information of China (English)

    Yimin Sun; Hanhan Li; Alan N. Langnas; Yong Zhao

    2004-01-01

    It is well known that leukocyte composition, T cell phenotypes and immune function change in aged mice and humans. However, limited and conflicting results on the age-related immune changes in middle-aged mice were reported. Identification of the characteristics of allogeneic immune responses in aging mice may offer important information for transplantation immunology. The major age-related changes in the immune cell phenotypes and function of 12 months old mice include: 1) the significantly decreased CD4+ cell population in the peripheral blood, the major peripheral CD4+ cells is CD45RBlowCD62Llow memory phenotype; 2) the in vitro responses to alloantigens and Con A of splenocytes markedly reduced; 3) the in vivo secondary humoral immune responses to alloantigens significantly declined; 4) the age-related alteration in the thymus mainly occurred in CD4/CD8 double positive (DP) stage; and 5) increased CD80+ and MHC class Ⅱ+ cell population in spleens. Thus, the major age-related immune changes in 12 months old mice occurred in CD4+ T cells in the periphery and DP stage in the thymus, which may subsequently lead to the decreased allogeneic immune responses and the different sensitivity to immunosuppressive drugs and treatments. Further studies on the characteristics of allogeneic immunity in aging individuals may help to determine the appropriated treatment for transplant aging individuals. Cellular & Molecular Immunology. 2004; 1(6) :440-446.

  7. Surgical technique for allogeneic uterus transplantation in macaques

    Science.gov (United States)

    Obara, Hideaki; Kisu, Iori; Kato, Yojiro; Yamada, Yohei; Matsubara, Kentaro; Emoto, Katsura; Adachi, Masataka; Matoba, Yusuke; Umene, Kiyoko; Nogami, Yuya; Banno, Kouji; Tsuchiya, Hideaki; Itagaki, Iori; Kawamoto, Ikuo; Nakagawa, Takahiro; Ishigaki, Hirohito; Itoh, Yasushi; Ogasawara, Kazumasa; Saiki, Yoko; Sato, Shin-ichi; Nakagawa, Kenshi; Shiina, Takashi; Aoki, Daisuke; Kitagawa, Yuko

    2016-01-01

    No study has reported an animal model of uterus transplantation (UTx) using cynomolgus macaques. We aimed to establish a surgical technique of allogeneic UTx assuming the recovery of a uterus from a deceased donor in cynomolgus macaques. Four allogeneic UTxs were performed in female cynomolgus macaques. Donor surgeries comprised en bloc recovery of organs with iliac vessels on both sides, and/or abdominal aorta/vena cava after sufficient perfusion from one femoral artery or external iliac artery. Before perfusion, 150 mL of whole blood was obtained from the donor for subsequent blood transfusion to the recipient. Four uterine grafts were orthotopically transplanted to recipients. End-to-side anastomosis was performed to the iliac vessels on one side in case 1 and iliac vessels on both sides in case 2; aorto-aorto/cavo-caval anastomosis was performed in cases 3 and 4. Arterial blood flow of the uterine grafts was determined by intraoperative indocyanine green (ICG) angiography. ICG angiography results showed sufficient blood flow to all uterine grafts, and anaemia did not progress. Under appropriate immune suppression, all recipients survived for more than 90 days post-transplantation, without any surgical complications. We describe a surgical technique for allogeneic UTx in cynomolgus macaques. PMID:27786258

  8. Repair of osteochondral defects with allogeneic tissue engineered cartilage implants.

    Science.gov (United States)

    Schreiber, R E; Ilten-Kirby, B M; Dunkelman, N S; Symons, K T; Rekettye, L M; Willoughby, J; Ratcliffe, A

    1999-10-01

    The objective of this study was to evaluate the effect of allogeneic tissue engineered cartilage implants on healing of osteochondral defects. Rabbit chondrocytes were cultured in monolayer, then seeded onto biodegradable, three-dimensional polyglycolic acid meshes. Cartilage constructs were cultured hydrodynamically to yield tissue with relatively more (mature) or less (immature) hyalinelike cartilage, as compared with adult rabbit articular cartilage. Osteochondral defects in the patellar grooves of both stifle joints either were left untreated or implanted with allogeneic tissue engineered cartilage. Histologic samples from in and around the defect sites were examined 3, 6, 9, and 12, and 24 months after surgery. By 9 months after surgery, defects sites treated with cartilage implants contained significantly greater amounts of hyalinelike cartilage with high levels of proteoglycan, and had a smooth, nonfibrillated articular surface as compared to untreated defects. In contrast, the repair tissue formed in untreated defects had fibrillated articular surfaces, significant amounts of fibrocartilage, and negligible proteoglycan. These differences between treated and untreated defects persisted through 24 months after surgery. The results of this study suggest that the treatment of osteochondral lesions with allogenic tissue engineered cartilage implants may lead to superior repair tissue than that found in untreated osteochondral lesions.

  9. Allogeneic leukocytes in cardiac surgery: Good or bad?

    Directory of Open Access Journals (Sweden)

    Anneke Brand

    2011-09-01

    Full Text Available Worldwide, cardiac surgery is a common procedure requiring a large quantity of allogeneic blood products, which are associated with postoperative complications. Leukocytes present in blood products may play a role in these complications, which are referred to as transfusion-related immunomodulation (TRIM. Several randomized controlled trials (RCTs in different settings investigated the effects of allogeneic leukocytes in red blood cells (RBCs. Cardiac surgery studies reported a reduction in postoperative infections and mortality in patients that received leukocyte-reduced RBCs compared with leukocyte-containing RBCs; this was mainly due to more deaths due to infections and multiple organ dysfunction syndrome (MODS in the group that received leukocyte-containing RBCs. Patients with postoperative complications had higher concentrations of inflammatory mediators. These findings suggest that leukocyte-containing transfusion during cardiac surgery induces a second insult to the systemic inflammatory response. In the present review we discuss the possible role of blood transfusions in cardiac surgery. Especially, we focus on the possible role of allogeneic leukocytes associated with postoperative complications after cardiac surgery.

  10. Altered Allogeneic Immune Responses in Middle-Aged Mice

    Institute of Scientific and Technical Information of China (English)

    YiminSun; HanhanLi; AlanN.Langnas

    2004-01-01

    It is well known that leukocyte composition, T cell phenotypes and immune function change in aged mice and humans. However, limited and conflicting results on the age-related immune changes in middle-aged mice were reported. Identification of the characteristics of allogeneic immune responses in aging mice may offer important information for transplantation immunology. The major age-related changes in the immune cell phenotypes and function of 12 months old mice include: 1) the significantly decreased CD4+ cell population in the peripheral blood, the major peripheral CD4+ cells is CD45RBlowCD62Llow memory phenotype; 2) the in vitro responses to alloantigens and Con A of splenocytes markedly reduced; 3) the in vivo secondary humoral immune responses to alloantigens significantly declined; 4) the age-related alteration in the thymus mainly occurred in CD4/CD8 double positive (DP) stage; and 5) increased CD80+ and MHC class II+ cell population in spleens. Thus, the major age-related immune changes in 12 months old mice occurred in CD4+ T cells in the periphery and DP stage in the thymus, which may subsequently lead to the decreased allogeneic immune responses and the different sensitivity to immunosuppressive drugs and treatments. Further studies on the characteristics of allogeneic immunity in aging individuals may help to determine the appropriated treatment for transplant aging individuals. Cellular & Molecular Immunology. 2004;1(6):440-446.

  11. Allogeneic Mesenchymal Stem Cell Treatment Induces Specific Alloantibodies in Horses

    Directory of Open Access Journals (Sweden)

    Sean D. Owens

    2016-01-01

    Full Text Available Background. It is unknown whether horses that receive allogeneic mesenchymal stem cells (MSCs injections develop specific humoral immune response. Our goal was to develop and validate a flow cytometric MSC crossmatch procedure and to determine if horses that received allogeneic MSCs in a clinical setting developed measurable antibodies following MSC administration. Methods. Serum was collected from a total of 19 horses enrolled in 3 different research projects. Horses in the 3 studies all received unmatched allogeneic MSCs. Bone marrow (BM or adipose tissue derived MSCs (ad-MSCs were administered via intravenous, intra-arterial, intratendon, or intraocular routes. Anti-MSCs and anti-bovine serum albumin antibodies were detected via flow cytometry and ELISA, respectively. Results. Overall, anti-MSC antibodies were detected in 37% of the horses. The majority of horses (89% were positive for anti-bovine serum albumin (BSA antibodies prior to and after MSC injection. Finally, there was no correlation between the amount of anti-BSA antibody and the development of anti-MSC antibodies. Conclusion. Anti allo-MSC antibody development was common; however, the significance of these antibodies is unknown. There was no correlation between either the presence or absence of antibodies and the percent antibody binding to MSCs and any adverse reaction to a MSC injection.

  12. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  13. Professoren og Ålen

    DEFF Research Database (Denmark)

    Poulsen, Bo

    2016-01-01

    Biolog og havforsker Johannes Schmidt regnes for at være Danmarks mest betydningsfulde havforsker gennem tiderne. Hans mange forskningsbaserede jordomsejlinger bragte ham til eksotiske egne og til opdagelsen af adskillige nye dyrearter. Dog blev særligt ålen og dens gydepladser et hovedfokus...

  14. Professoren og Ålen

    DEFF Research Database (Denmark)

    Poulsen, Bo

    2016-01-01

    Biolog og havforsker Johannes Schmidt regnes for at være Danmarks mest betydningsfulde havforsker gennem tiderne. Hans mange forskningsbaserede jordomsejlinger bragte ham til eksotiske egne og til opdagelsen af adskillige nye dyrearter. Dog blev særligt ålen og dens gydepladser et hovedfokus for ...

  15. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  16. Estimation of the hybrid lens parameters through rigid gas permeable lens fitting

    OpenAIRE

    Hasani, Mohammadali; Hashemi, Hassan; Jafarzadehpur, Ebrahim; Yekta, Abbas Ali; Dadbin, Nooshin; khabazkhoob, Mehdi

    2016-01-01

    Purpose To estimate the fitting parameters of the hybrid contact lens in patients with corneal ectasia using the rigid gas permeable (RGP) lens. Methods Thirty-four eyes with corneal ectasia were evaluated in this study. The patients were examined once with the RGP lens and once with the hybrid contact lens. The relationship between the base curvature of the RGP and the vault of the hybrid lens and the correlation between their powers were analyzed. Results We found a linear relationship betw...

  17. Pigment Epithelium-derived Factor in Cataractous Aqueous Humor and Lens Epithelial Cells

    Institute of Scientific and Technical Information of China (English)

    Tian Liu; Yizhi Liu; Mingxing Wu

    2006-01-01

    Purpose:To study the characteristics of PEDF in cataractous aqueous humor and its expression in human lens epithelium.Methods:The PEDF concentration in the aqueous humor was measured by enzyme linked immunosorbent assay in senile (130cases) and congenital (18cases) cataract patients who underwent cataract phacoemulsification extraction surgery. Anterior lens capsular specimens were obtained from these patients to count lens epithelial cells(LEC) density. The Lens Opacities Classification System Ⅲ was used to classify the senile cataracts as cortical, nuclear, posterior subcapsular and mixed types of opacity, and quantitative analysis of the nuclear opacities was performed by Pentacam Scheimpflug imaging system. Anterior lens capsular specimens from another senile(10cases) and congenital (10cases) cataract were collected for immunofluorescence with polyclonal antibodies specific to human pigment epithelium-derived factor(PEDF).Results:The mean aqueous level of PEDF was(178. 9±87. 5)ng/ml, and there was negative linear correlation of PEDF level and age (r=0. 811, P < 0. 001) . In senile cases, the aqueous PEDF concentration decreased with increasing nuclear opacities(r=0. 447, P < 0.01 ), and the mean PEDF level in nuclear cataract was significantly lower than that in posterior subcapsular opacity (P < 0.01 ) . PEDF immunostaining was detected in LEC of all capsular specimens.Conclusion :The PEDF level in human aqueous humor is related to age, types of cataracts and lens opacity. PEDF also express in human LEC. The study results suggest PEDF may regulate and/or protect LEC by paracrine and autocrine, and lack of PEDF may play a role in cataractogenesis.

  18. Multifocal contact lens myopia control.

    Science.gov (United States)

    Walline, Jeffrey J; Greiner, Katie L; McVey, M Elizabeth; Jones-Jordan, Lisa A

    2013-11-01

    Previous studies on soft multifocal contact lens myopia control published in the peer-reviewed literature reported findings of noncommercial contact lenses worn for 1 year or less. This study sought to determine the progression of myopia and axial elongation of children fitted with commercially available distance center soft multifocal contact lenses for 2 years. Eight- to eleven-year-old children with -1.00 D to -6.00 D spherical component and less than 1.00 D astigmatism were fitted with soft multifocal contact lenses with a +2.00 D add (Proclear Multifocal "D"; CooperVision, Fairport, NY). They were age- and gender-matched to participants from a previous study who were fitted with single-vision contact lenses (1 Day Acuvue; Vistakon, Jacksonville, FL). A-scan ultrasound and cycloplegic autorefraction were performed at baseline, after 1 year, and after 2 years. Multilevel modeling was used to compare the rate of change of myopia and axial length between single-vision and soft multifocal contact lens wearers. Forty participants were fitted with soft multifocal contact lenses, and 13 did not contribute complete data (5 contributed 1 year of data). The adjusted mean ± standard error spherical equivalent progression of myopia at 2 years was -1.03 ± 0.06 D for the single-vision contact lens wearers and -0.51 ± 0.06 for the soft multifocal contact lens wearers (p < 0.0001). The adjusted mean axial elongation was 0.41 ± 0.03 and 0.29 ± 0.03 for the single-vision and soft multifocal contact lens wearers, respectively (p < 0.0016). Soft multifocal contact lens wear resulted in a 50% reduction in the progression of myopia and a 29% reduction in axial elongation during the 2-year treatment period compared to a historical control group. Results from this and other investigations indicate a need for a long-term randomized clinical trial to investigate the potential for soft multifocal contact lens myopia control.

  19. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...... the aesthetic results when orthodontic therapy itself is not feasible. This article presents integrated orthodonticrestorative solutions of anterior diastemata, associated with the conditioning of the gingival tissue with composite resin, and discusses the most relevant aspects related to their etiology...

  20. Effect of phacoemulsification, intraocular lens implantation, and trabeculectomy on angle-closure glaucoma merged with cataract

    Institute of Scientific and Technical Information of China (English)

    Qun Wu; Li-Li Hao; Wen-Xuan Tao; Chun-Xiang Liu

    2016-01-01

    Objective:To explore the clinical effect of phacoemulsification, intraocular lens implantation, and trabeculectomy in the treatment of angle-closure glaucoma merged with cataract. Methods:A total of 80 patients with angle-closure glaucoma merged with cataract who were admitted in our hospital from May, 2015 to May, 2016 were included in the study and randomized into the observation group and the control group. The patients in the control group were given phacoemulsification and intraocular lens implantation. On this basis, the patients in the observation group were given trabeculectomy. The vision, intraocular pressure, central anterior chamber depth, and visual field before operation, 1 week, 1 month, and 3 months after operation in the two groups were detected.Results: In the control group, 1 month after operation, while in the observation group, 1 week after operation, the vision was significantly improved, the intraocular pressure was significantly reduced, the central anterior chamber depth was significantly increased, and the average visual field defect value and average standard deviation value were significantly improved when compared with before operation (P<0.05); moreover, the improved degree in the observation group was significantly superior to that in the control group (P<0.05).Conclusions:Phacoemulsification, intraocular lens implantation, and trabeculectomy in the treatment of angle-closure glaucoma merged with cataract can effectively increase the central anterior chamber depth, reduce the intraocular pressure, and improve the vision; therefore, it deserves to be widely recommended in the clinic.

  1. Anterior knee pain: uncommon aetiologies

    Directory of Open Access Journals (Sweden)

    Q. Louw

    2003-02-01

    Full Text Available The aim of this review is to inform clinicians of less common causes of anterior knee pain. Relatively less common conditions leading to anterior knee pain include infra-patellar contracture syndrome, conditions affecting the fat pad, saphenous nerve entrapment, prepatellar neuromas, increased intraosseous pressure of the patella, ganglions of the anterior cruciate ligament and cysts. The aetiology, clinical presentation, risk factors and management  of each condition are outlined. Due to the common occurrence of anterior knee pain clinicians must remain vigilant in assessing the cause of this clinical presentation.

  2. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  3. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  4. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study

    Science.gov (United States)

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313

  5. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  6. Conjunctival impression cytology in contact lens wearers.

    Directory of Open Access Journals (Sweden)

    Simon Priya

    2002-01-01

    Full Text Available PURPOSE: To evaluate the cytological changes in conjunctiva following regular contact lens wear and to determine the correlation, if any, between severity of cytological alteration and symptoms related to contact lens wear. METHODS: One hundred eyes (50 normal asymptomatic subjects who served as a control group were studied by conjunctival impression cytology (CIC. These subjects were fitted with rigid gas permeable (RGP or soft contact lenses and were followed up at the end of 3 and 6 months. At each follow-up visit the CIC was repeated. A filter paper with the impression specimen was stained with periodic acid schiff (PAS and haematoxylin stain to study goblet cell loss. Papanicolaou stain was done to study squamous metaplasia. The cytological changes were graded using the system described by Natadisastra et al. RESULTS: Severity of cytological changes increased with the duration of contact lens wear (P = 0.00001. At the end of 6 months, 60% of symptomatic eyes wearing soft contact lens and RGP lens showed abnormal CIC changes. None of the asymptomatic RGP contact lens wearing eyes showed abnormal CIC changes whereas 33.4% of the asymptomatic soft contact lens wearing eyes showed abnormal CIC changes (P = 0.033. Epithelial changes occurred within 3-6 months of contact lens fitting. CONCLUSION: Severity of cytological changes increased with duration of lens wear (P = 0.00001. Prevalence and severity of cytological alteration is more in symptomatic contact lens wearers. Soft contact lens wearers although asymptomatic showed severe CIC changes.

  7. [Anterior cervical hypertrichosis: case report].

    Science.gov (United States)

    Orozco-Gutiérrez, Mario H; Sánchez-Corona, José; García-Ortiz, José E; Castañeda-Cisneros, Gema; Dávalos-Rodríguez, Nory O; Corona-Rivera, Jorge R; García-Cruz, Diana

    2016-10-01

    The non-syndromic anterior cervical hypertrichosis (OMIM N° 600457) is a genetic disorder characterized by a patch of hair at the level of the laryngeal prominence. We present a 12-year-old boy with anterior cervical hypertrichosis and mild generalized hypertrichosis. He has no neurological, ophthalmological or skeletal anomalies. The clinical follow up is 10 years.

  8. Effect of intrathymic injection of allogene antigen on immune response to sciatic nerve transplantation in allogenic mice

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    BACKGROUND: The latest researches demonstrate that intrathymic injection of MHC antigen which reaches a certain dosage (2 mg, i.e., 4 × 108 cell extraction) can induce immunologic tolerance under non-antilymphocyte serum condition.OBJECTIVE: To investigate the effect of intrathymic injection of allogene antigen on survival and function of sciatic nerve in allogenic mice.DESIGN: Randomized controlled animal study.SETTING: The 4th Affiliated Hosptial of Harbin Medical University.MATERIALS: A total of 32 male donor C57BL/6(H-2b) mice of 4 - 8 weeks old and weighing 18 - 22 g and 44 female receptor Balb/c(H-2d) mice of 4 - 8 weeks old and weighing 18 - 22 g were selected from Heilongjing Veterinary Institution. The animal experiment had got confirmed consent from local ethic committee.METHODS: The experiment was carried out in the Laboratory (Provincial Key Laboratory) of the Fourth Hospital, Harbin Medical University from June 2006 to May 2007. C57BL/6(H-2b) mice were anesthetized to extract MHC (H-2b) antigen from splenic cells and sciatic nerves. Allogenous nerve transplantation group:Mice were given intrathymic injection of 100 μ L saline; two weeks later, frozen sciatic nerves of donor mice were transplanted. Immunosuppressive agent group: Mice were given intrathymic injection of 100 μ L saline; two weeks later, fresh sciatic nerves of donor mice were transplanted. At three days before transplantation, 10 mg/kg per day cyclosporin A was intraperitoneally injected once a day till mice were sacrificed. MHC (H-2b) antigen injection group: Mice were given intrathymic injection of MHC (H-2b)antigen from C57BL/6(H-2b) donor mice; two weeks later, fresh sciatic nerves of donor mice were transplanted. Autogenous nerve transplantation group: Mice were given intrathymic injection of 100 μ L saline; two weeks later, fresh sciatic nerves were transplanted.MAIN OUTCOME MEASURES: ① Three weeks later, transplanted part of exposured sciatic nerve was used to measure the

  9. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Bruna Vieira Ventura

    Full Text Available ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  10. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens.

    Science.gov (United States)

    Ventura, Bruna Vieira; MacLean, Kyle Douglas; Lira, Wagner; Oliveira, Daniele Mendes de; Ventura, Camila Vieira; Werner, Liliana

    2016-01-01

    A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  11. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  12. A case of iridoschisis associated with lens displacement into the vitreous cavity

    Directory of Open Access Journals (Sweden)

    Tetsuya Mutoh

    2010-05-01

    Full Text Available Tetsuya Mutoh1, Yukihiro Matsumoto1, Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Saitama, JapanAbstract: We report the case of a 67-year-old woman with a lens that was displaced into the vitreous cavity in one eye and ipsilateral iridoschisis. She was free from a history of ocular trauma or of heritable ocular disease. Her best-corrected visual acuity was 1.2 bilaterally and right eye showed signs of iridoschisis. The corneal endothelial cell density decreased to 1,263 cells/mm2 in the right eye preoperatively. We speculated that iris tissue flowing in the anterior chamber might have intermittently touched the corneal endothelium. 25-gauge pars plana vitrectomy and lens removal were performed immediately. Free-floating iris tissue was cut during surgery with care not to injure the corneal endothelial cells. The postoperative progress was satisfactory and scleral fixation of an intraocular lens is planned. Iridoschisis is an uncommon cause of lens displacement into the vitreous cavity.Keywords: lens displacement, vitreous cavity, iridoschisis, corneal endothelial cell density, free-floating iris tissue

  13. Lens Epithelial Cell Death Secondary to Acanthamoeba Keratitis: Absence of Capsular Bag Opacification Six Years after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Javier Moreno-Montañés

    2011-12-01

    Full Text Available Purpose: To show the evolution of anterior chamber structures 6 years after cataract surgery in a case with Acanthamoeba keratitis (AK. Methods: A 37-year-old woman with AK receiving long-term treatment with chlorhexidine, propamidine isethionate and steroids developed a white cataract and iris atrophy. Penetrating keratoplasty and cataract surgery were performed with subsequent intraocular pressure elevation requiring Molteno shunt implantation. Two years after the last surgery, endothelial decompensation developed and another penetrating keratoplasty was performed. Intraoperatively, the anterior and posterior capsules were completely transparent. Results: Six years after cataract surgery, the intraocular lens was centered with clear anterior and posterior capsules without lens epithelial cells proliferation. No Soemmering’s ring formation or posterior capsule opacification was found. Also, no zonular damage or pseudophacodonesis was observed. Conclusions: This case suggests that AK infection and AK treatment not only cause white progressive cataract but also lens epithelial cell death. The capsules may be completely clear 6 years after cataract surgery, with a good quality of vision regardless of intraocular lens material or design.

  14. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  15. Inestabilidad Anterior de Hombro

    Directory of Open Access Journals (Sweden)

    Pablo David Flint Kuran

    2013-11-01

    Full Text Available In­tro­duc­ción La luxación recidivante de hombro es una patología frecuente en pacientes jóvenes, laboralmente activos. Existen numerosas técnicas quirúrgicas para la inestabilidad glenohumeral. La técnica de Bristow, discutida por no ser anatómica y por sus complicaciones, continúa vigente debido al bajo índice de reluxaciones. Los objetivos fueron determinar el índice de recidiva, alteraciones funcionales e índice de consolidación del injerto. Materiales­ y­ Métodos Se evaluaron 24 pacientes del sexo masculino, de entre 19 y 40 años, operados por luxación anterior recidivante de hombro según la técnica de Bristow, entre enero de 2003 y agosto de 2011. Se evaluó la tasa de reluxación, la función articular según el puntaje de Constant y el posicionamiento del injerto con respecto a la superficie articular con tomografía y radiografías para evaluar la consolidación del injerto. Se registraron las complicaciones quirúrgicas. Resultados ­Todos los pacientes eran hombres, con rango de edad de 19 a 40 años. La causa fue traumática en 24 pacientes. Dieciséis pacientes presentaron más de 3 episodios de luxación prequirúrgicos. Según la escala de Constant, 21 obtuvieron entre 96 y 100 puntos, y los restantes, entre 90 y 95 puntos. No hubo nuevos episodios de luxaciones. La tomografía mostró la consolidación en todos los casos. Un paciente tuvo una imagen osteolítica alrededor del tornillo, sin compromiso funcional del hombro. Conclusión La técnica de Bristow para tratar la luxación anterior recidivante de hombro provocó un bajo índice de complicaciones, con resultados funcionales entre excelentes y buenos. No hubo episodios de reluxación y se logró la consolidación del injerto óseo en todos los casos.

  16. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  17. Fresnel Lens with Embedded Vortices

    Directory of Open Access Journals (Sweden)

    Sunil Vyas

    2012-01-01

    Full Text Available Vortices of different charges are embedded in a wavefront that has quadratic phase variation, and the intensity distribution near the focal plane is studied. This method may be useful in realizing complicated beam profiles. We have experimentally demonstrated the generation of vortex arrays having integer as well as fractional topological charges that produce different intensity profiles at the focal plane. The phase variation realized on a spatial light modulator (SLM acts as a Fresnel lens with embedded vortices.

  18. Corneal confocal microscopy and dry eye findings in contact lens discomfort patients.

    Science.gov (United States)

    Dogan, Aysun Sanal; Gurdal, Canan; Arslan, Nese

    2017-08-16

    To evaluate the corneal confocal microscopy and dry eye findings in patients with contact lens discomfort. The study included 3 groups of participants: Contact lens wearers using silicone hydrogel soft contact lenses who are symptomatic (CLD, n=15) or asymptomatic (ACL, n=11) and non-wearers as controls (n=14). Duration of contact lens wear, Ocular Surface Disease Index (OSDI) questionnaire responses, fluorescein tear break-uptime (FBUT), and corneal confocal microscopy findings were recorded. Mean age was 25.7±8.2 years and male/female ratio was 7/33. Demographic findings were similar regarding the groups. CLD patients had a longer lens use history than ACL (median 5 vs 2 years, p<0.001). OSDI scores were higher in CLD group than ACL or controls (p<0.001, p=0.002). FBUT was significantly lowest in CLD group, compared to controls and ACL (p<0.001, p=0.039). FBUT was also lower in ACL patients compared to controls (p=0.036). There was no difference between basal epithelium cell counts between all 3 groups. Anterior stromal activated keratocyte numbers were similar between contact lens using groups but was lower in controls (p=0.005). However, dendritiform cells in the sub-basal nerve layer were higher in CLD group compared to controls but similar to ACL (p<0.001, p=0.058). Graded sub-basal nerve tortuosity was more prominent in CLD group than the ACL (p=0.014). Patients with CLD had been wearing contact lenses for longer than those without symptoms. OSDI and FBUT scores were worse in CLD patients. In contact lens discomfort patients, there were increased dendritiform cells, indicating intensified inflammatory status of the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Effects of age on ocular anterior segment dimensions measured by optical coherence tomography

    Institute of Scientific and Technical Information of China (English)

    QIN Bing; ZHOU Xing-tao; HUANG David; CHU Ren-yuan

    2011-01-01

    Background Older subjects tend to have smaller ocular anterior segment. The present study aimed to measure anterior segment dimensions with optical coherence tomography (OCT) and quantitatively assess the effect of age and other factors.Results Sixty-six eyes of 33 normal subjects (aged 22-65 years, 19 Asians, 14 Caucasians) were enrolled. For every 1 year of age, corneal diameter was 0.033 mm narrower (P <0.01), anterior chamber width was 0.031 mm narrower (P <0.01), corneal vault was 0.016 mm lower (P<0.01), and anterior chamber depth was 0.025 mm lower (P<0.01). Asian eyes had smaller corneal diameter (P=0.035) and anterior chamber width (P=0.015) compared with those of Caucasian eyes. Body height showed positive correlation with corneal diameter (0.039 mm per centimeter of height, P <0.01) and corneal vault (0.024 mm per centimetre of height, P <0.01). Gender did not have an independent effect on anterior segment dimensions.Conclusions Anterior segment dimensions were smaller in older subjects. Age-related changes may affect the tolerability of long-term implants such as phakic intraocular lens.

  20. [Numerical Simulation of Heat Transfer in the Human Anterior Chamber at Different Corneal Temperatures].

    Science.gov (United States)

    Guo, Jingmin; Zhang, Hong; Wang, Junming

    2015-12-01

    A three-dimensional (3D) model of human anterior chamber is reconstructed to explore the effect of different corneal temperatures on the heat transfer in the chamber. Based on the optical coherence tomography imaging of the volunteers with normal anterior chamber, a 3D anterior chamber model was reconstructed by the method of UG parametric design. Numerical simulation of heat transfer and aqueous humor flow in the whole anterior chamber were analyzed by the finite volume methods at different corneal temperatures. The results showed that different corneal temperatures had obvious influence on the temperature distribution and the aqueous flow in the anterior chamber. The temperature distribution is linear and axial symmetrical around the pupillary axis. As the temperature difference increases, the symmetry becomes poorer. Aqueous floated along the warm side and sank along the cool side which forms a vortexing flow. Its velocity increased with the addition of temperature difference. Heat fluxes of cornea, lens and iris were mainly affected by the aqueous velocity. The higher the velocity, the bigger more absolute value of the above-mentioned heat fluxes became. It is practicable to perform the numerical simulation of anterior chamber by the optical coherence tomography imaging. The results are useful for studying the important effect of corneal temperature on the heat transfer and aqueous humor dynamics in the anterior chamber.

  1. RENAL ALLOGENEIC TRANSPLANTATION IN PATIENT WITH HAEMOPHILIA B

    Directory of Open Access Journals (Sweden)

    N. V. Purlo

    2014-01-01

    Full Text Available We report the case of successful renal allogeneic transplantation and treatment in a 56-year-old patient with haemophilia B at Hematology Research Center. He has received replacement therapy by factor IX since 2010. The transplant is marked with good renal function during 13 post-transplant months without episodes of rejection or bleeding complications. The complicated surgical interventions are possible in patients with haemophilia В аnd end-stage chronic renal failure in the presence of replacement therapy of IX factor for the purpose of achievement of optimum hemostasis.

  2. Donor lymphocyte infusion after allogeneic stem cell transplantation.

    Science.gov (United States)

    Castagna, Luca; Sarina, Barbara; Bramanti, Stefania; Perseghin, Paolo; Mariotti, Jacopo; Morabito, Lucio

    2016-06-01

    Allogeneic stem cell transplantation (allo-SCT) is considered the cornerstone in the treatment of several malignant and not malignant hematological diseases. However, relapse of hematological disease after allo-SCT is considered the most challenging point in the field. The risk can be reduced through optimal patients, donor and disease selection before allo-SCT, but harnessing donor immune system is an appealing way to treat or avoid disease relapse. Donor lymphocyte infusion (DLI) is a simple and effective therapy after allo-SCT. In this paper, the efficacy of DLI will be analyzed in different hematological diseases, focusing also on their therapeutic or pre-emptive use.

  3. Damage to lens fiber cells causes TRPV4-dependent Src family kinase activation in the epithelium.

    Science.gov (United States)

    Shahidullah, M; Mandal, A; Delamere, N A

    2015-11-01

    The bulk of the lens consists of tightly packed fiber cells. Because mature lens fibers lack mitochondria and other organelles, lens homeostasis relies on a monolayer of epithelial cells at the anterior surface. The detection of various signaling pathways in lens epithelial cells suggests they respond to stimuli that influence lens function. Focusing on Src Family Kinases (SFKs) and Transient Receptor Potential Vanilloid 4 (TRPV4), we tested whether the epithelium can sense and respond to an event that occurs in fiber mass. The pig lens was subjected to localized freeze-thaw (FT) damage to fibers at posterior pole then the lens was incubated for 1-10 min in Krebs solution at 37 °C. Transient SFK activation in the epithelium was detectable at 1 min. Using a western blot approach, the ion channel TRPV4 was detected in the epithelium but was sparse or absent in fiber cells. Even though TRPV4 expression appears low at the actual site of FT damage to the fibers, SFK activation in the epithelium was suppressed in lenses subjected to FT damage then incubated with the TRPV4 antagonist HC067047 (10 μM). Na,K-ATPase activity was examined because previous studies report changes of Na,K-ATPase activity associated with SFK activation. Na,K-ATPase activity doubled in the epithelium removed from FT-damaged lenses and the response was prevented by HC067047 or the SFK inhibitor PP2 (10 μM). Similar changes were observed in response to fiber damage caused by injection of 5 μl hyperosmotic NaCl or mannitol solution beneath the surface of the posterior pole. The findings point to a TRPV4-dependent mechanism that enables the epithelial cells to detect remote damage in the fiber mass and respond within minutes by activating SFK and increasing Na,K-ATPase activity. Because TRPV4 channels are mechanosensitive, we speculate they may be stimulated by swelling of the lens structure caused by damage to the fibers. Increased Na,K-ATPase activity gives the lens greater capacity to

  4. Hydroimplantation: foldable intraocular lens implantation without an ophthalmic viscosurgical device.

    Science.gov (United States)

    Tak, Harshul

    2010-03-01

    I describe a technique for implantation of a 1-piece acrylic foldable intraocular lens (IOL) using an irrigation cannula of the phaco machine without using an ophthalmic viscosurgical device (OVD). The irrigating cannula introduced through a side port provides excellent stability and positioning to the eye; if required, the cannula tip is used to guide the leading haptic of the IOL into the capsular bag. The fluid coming from the side port via a bimanual irrigation cannula maintains adequate formation of the capsular bag and anterior chamber while the foldable IOL is inserted. The hydroimplantation technique has the advantage of increased efficiency, reduced surgical time and cost, no need for OVD removal from behind the IOL or for additional instrumentation, no OVD-induced intraocular pressure elevation postoperatively, and no risk of early capsular bag distension syndrome. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Outcomes of Phacoemulsification with Anterior Chamber Maintainer in Vitrectomized Eyes

    Directory of Open Access Journals (Sweden)

    Elif Betül Türkoğlu

    2012-07-01

    Full Text Available Pur po se: To evaluate the outcomes of phacoemulsification with anterior chamber maintainer in vitrectomized eyes with complicated cataract. Ma te ri al and Met hod: Twenty eyes of 20 patients who developed complicated cataract after pars plana vitrectomy (PPV were included in the study. Phacoemulsification with clear corneal incision and foldable intraocular lens implantation was performed. In group 1, anterior chamber maintainer (ACM was used during phacoemusification and in group 2, ACM was not used. Pre- and postoperative visual acuities as well as per- and postoperative complications were reviewed retrospectively. Re sults: Anterior chamber maintainer was used during the surgery in 12 (60% cases and was not used in 8 (40% cases. Phacoemulsification was performed 16.5±9.2 (4-40 months after PPV. Best-corrected visual acuities were between hand motions and 0.4 preoperatively and between counting fingers from 1 meter and 1.0 postoperatively in group 1. Best-corrected visual acuities were between hand motions and 0.1 preoperatively and between counting fingers from 1 meter and 0.8 postoperatively in group 2. Posterior capsule was ruptured in 1 eye peroperatively in group 1. In group 2, phacoemulsification was more difficult due to deep anterior chamber in 8 eyes and intraoperative complications were iris sphincter rupture in 1 eye and posterior capsule rupture in 1 eye. Mild corneal edema in 7 (58.3% eyes, fibrin reaction in 2 (16.6%, intraocular lens decentralization in 1 (8.3% and posterior capsule opacification in 4 (33.3% eyes were the postoperative complications in group 1. Mild corneal edema in 5 (62.5% eyes, fibrin reaction in 1 (12.5% and posterior capsule opacification in 2 (25% eyes were the postoperative complications in group 2. Dis cus si on: Complicated cataracts which may develop after PPV can be treated safely with phacoemulsification. Continuous irrigation during the surgery may provide a stable anterior chamber and prevents

  6. Refractive Outcomes of Three-Port Lens-Sparing Vitrectomy for Retinopathy of Prematurity (An AOS Thesis)

    Science.gov (United States)

    Holz, Eric R.

    2009-01-01

    Purpose: To study the refractive outcomes of 3-port lens-sparing vitrectomy (LSV) for subtotal retinal detachments due to retinopathy of prematurity (ROP). Lens-sparing vitrectomy may provide superior refractive outcomes by limiting induced myopia of prematurity. Methods: This is a retrospective, consecutive, nonrandomized, comparative (paired eye) study. Entrance criteria were previous complete ablative laser for threshold ROP in both eyes, followed by LSV in one eye for stage 4A traction retinal detachment. Both eyes then maintained complete retinal attachment. Main outcome variables were cycloplegic refraction, keratometry, and biometric values for axial length, lens thickness, and anterior chamber depth. Results: Nine patients met inclusion criteria. Lens-sparing vitrectomy eyes were significantly less myopic than control eyes (−6.78 D vs −10.33 D, P < .005). The reduction in myopia in LSV eyes was predominantly due to increased anterior chamber depth (3.81 mm ± 0.217 vs 2.96 mm ± 0.232, P < .005). There was a minor contribution from reduced corneal power in LSV eyes (43.89 D ± 0.253 vs 44.20 D ± 0.265, P < .005). There was a minor negative impact from increased lens thickness in LSV eyes (3.85 ± 0.32 mm vs 3.74 ± 0.31, P < .005). There was no significant difference in axial length or lens power between the LSV and control groups. Conclusions: The data demonstrate that infant eyes undergoing 3-port LSV for stage 4A ROP develop less myopia than fellow eyes treated with laser alone. The difference is due to posterior displacement of the lens-iris diaphragm with a smaller contribution from reduced corneal power. The reduction in myopia may improve functional outcomes following 3-port LSV for stage 4A ROP. PMID:20126504

  7. Evolution of a pre and post lens tear film with a contact lens

    Science.gov (United States)

    Gerhart, Matthew; Anderson, Daniel

    2012-11-01

    The work is the development, implementation, and analysis of a two-dimensional tear film model including a porous contact lens. The geometry of the problem is: a pre-lens layer that is a thin tear film between the outside air and contact lens, a contact lens that is a rigid but movable porous substrate, and a post-lens layer that is a thin film layer between the contact lens and the cornea. We are looking at short and long term behavior of the evolution of the thin film in the pre-lens layer coupled with the porous layer and the thin squeeze film in the post-lens layer. We model the different behaviors that arise as the Darcy number, evaporation effects, and boundary flux conditions change.

  8. Vitreoretinal Surgery for Intraocular Lens Dislocated into the Vitreous Cavity

    Directory of Open Access Journals (Sweden)

    Dilek Özçelik Soba

    2015-04-01

    Full Text Available Objectives: To investigate the sex, age, accompanying eye examination findings, and the outcomes of vitreoretinal surgery (VRS for intraocular lens (IOL dislocated into the vitreous cavity. Materials and Methods: The medical records of 30 patients who underwent VRS for IOL dislocation into the vitreous cavity were retrospectively analyzed in this study. Preoperative and postoperative visual acuity, intraocular pressure, biomicroscopic, and posterior segment examination findings were assessed. Results: The average age of the patients was 63.1 (range: 38-83 years. Twenty-one patients were male (70% and 9 patients were female (30%. As etiologic causes, 18 cases (60% had late spontaneous dislocation, 5 cases (16.6% had dislocation after phacoemulsification surgery, 4 cases (13.3% had trauma, 2 cases (6.6% had previously undergone vitrectomy, and 1 case (3.3% had undergone YAG laser capsulotomy. VRS including 23-gauge triamcinolone-assisted pars plana vitrectomy, intraocular lens extraction, posterior hyaloid membrane removing, endolaser photocoagulation, and fluid-air exchange was performed. Posterior chamber IOL implantation on to the anterior capsule in 13 cases (43.3%, anterior chamber IOL implantation in 10 cases (33.3%, and scleral fixated posterior IOL implantation in 4 cases (13.3% were performed. The corrected visual acuity recorded at the last follow-up was better than the first visit in 23 cases (76.6%, the same in 5 eyes (16.6%, and worse in 2 eyes (6.6%. Conclusion: VRS combined IOL implantation is a successful surgery method for IOL dislocated into the vitreous cavity and can avoid poor visual outcomes. (Turk J Ophthalmol 2015; 45: 56-9

  9. Lateral shear interferometry with holo shear lens

    Science.gov (United States)

    Joenathan, C.; Mohanty, R. K.; Sirohi, R. S.

    1984-12-01

    A simple method for obtaining lateral shear using holo shear lenses (HSL) has been discussed. This simple device which produces lateral shears in the orthogonal directions has been used for lens testing. The holo shear lens is placed at or near the focus of the lens to be tested. It has also been shown that HSL can be used in speckle shear interferometry as it performs both the functions of shearing and imaging.

  10. An inverse and analytic lens design method

    OpenAIRE

    Lu, Yang; Lakshminarayanan, Vasudevan

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input ...

  11. Unilateral anterior uveitis complicating zoledronic acid therapy in breast cancer

    Directory of Open Access Journals (Sweden)

    El Saghir Nagi S

    2005-12-01

    Full Text Available Abstract Background Zoledronic acid is very widely used in patients with metastatic bone disease and osteoporosis. Only one case of bilateral uveitis was recently reported related to its use. Case presentation We report the first case of severe unilateral anterior uveitis in a patient with breast cancer and an intraocular lens. Following zoledronic acid infusion, the patient developed severe and dramatic right eye pain with decreased visual acuity within 24 hours and was found to have a fibrinous anterior uveitis of moderate severity The patient was treated with topical prednisone and atropine eyedrops and recovered slowly over several months. Conclusion Internists, oncologists, endocrinologists, and ophtalmologists should be aware of uveitis as a possible complication of zoledronic acid therapy. Patients should be instructed to report immediately to their physicians and treatment with topical prednisone and atropine eyedrops should be instituted immediately at the onset of symptoms. This report documents anterior uveitis as a complication of zoledronic acid therapy. This reaction could be an idiosyncratic one but further research may shed more light on the etiology.

  12. Lens opacities after repeated exposure to ultraviolet radiation.

    Science.gov (United States)

    Michael, R; Löfgren, S; Söderberg, P G

    1999-12-01

    To investigate the effect of the interval between two, near-threshold exposures to ultraviolet radiation (UVR) on cataract development. One eye of Sprague-Dawley rats was exposed twice to 4 kJ/m2 narrow band UVR (lambdaMAX=300 nm) for 15 min each. The interval between exposures was 0, 6, 24 or 48 h. One week after the first exposure both lenses were removed for photography and measurement of the intensity of forward light scattering to quantify lens opacities. All exposed lenses developed cataract. Forward light scattering was the same after double exposure with no interval or a 6 h interval. Forward light scattering after a 24 or 48 h interval was nearly twofold greater than that following no interval or a 6 h interval. The exposed lenses in all groups had mild anterior surface opacities and intense equatorial opacities as judged with a stereomicroscope. Two, near-threshold UVR exposures at 0 or a 6 h interval produce the same degree of lens opacification. When the second exposure follows 24 or 48 h after the first, lenticular damage increases. Repair processes between 24 and 48 h after exposure appear to be sensitive to UVR, and an additional exposure during this time may aggravate cataract development.

  13. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  14. A Magnification Lens for Interactive Volume Visualization

    Energy Technology Data Exchange (ETDEWEB)

    LaMar, E; Hamann, B; Joy, K I

    2001-07-19

    Volume visualization of large data sets suffers from the same problem that many other visualization modalities suffer from: either one can visualize the entire data set and lose small details or visualize a small region and lose the context. In this paper, they present a magnification lens technique for volume visualization. While the notion of a magnification-lens is not new, and other techniques attempt to simulate the physical properties of a magnifying lens, their contribution is in developing a magnification lens that is fast, can be implemented using a fairly small software overhead, and has a natural, intuitive appearance. The issue with magnification lens is the border, or transition, region. The lens center and exterior have a constant zoom factor, and are simple to render. It is the border region that blends between the external and interior magnification, and has a non-constant magnification. They use the perspective-correct textures capability, available in most current graphics systems, to produce a lens with a tessellated border region that approximates linear compression with respect to the radius of the magnification lens. They discuss how a cubic border can mitigate the discontinuities resulting from the use of a linear function, without significant performance loss. They discuss various issues concerning development of a three-dimensional magnification lens.

  15. Trends of contact lens prescribing in Jordan.

    Science.gov (United States)

    Haddad, Mera F; Bakkar, May; Gammoh, Yazan; Morgan, Philip

    2016-10-01

    To evaluate contact lens prescribing trends among optometrists in Jordan. Optometrists from 173 practices in Jordan were surveyed about prescribing contact lenses in their practice. Practitioners were required to record information for the last 10 patients that visited their practice. Demographic data such as age and gender was obtained for each patient. In addition, data relating to lens type, lens design, replacement methods and the care regime advised to each patient were recorded. Practitioners were required to provide information relating to their education and years of experience. The influence of education and experience with respect to lens prescribing trends was explored using linear regression models for the proportions of lens types fitted for patients. A total of 1730 contact lens fits were analyzed. The mean (±SD) age of lens wearers was 26.6 (±7.9) years, of whom 65% were female. Conventional hydrogel lenses were the most prescribed lenses, accounting for 60.3% of the fits, followed by silicone hydrogel lenses (31.3%), and rigid lenses (8.4%). In terms of lens design, spherical lenses appeared to be most commonly prescribed on monthly basis. Daily disposable lenses were second most prescribed lens modality, accounting for 20.4% of the study sample. Multi-purpose solution (MPS) was the preferred care regimen, with a prevalence of 88.1% reported in the study sample, compared to hydrogen peroxide (1-step and 2-step), which represented only 2.8% of the patients in this study. A relationship was established between the two educational groups for rigid lens prescribing (F=17.4, ptrends among optometrists in Jordan. Contact lens prescribing in terms of lens type, lens design, modality of wear and care regimen agree with global market trends with small variations. This report will help practitioners and the industry to detect any deficiencies in the contact lens market in Jordan, which will ease implementing current and future plans in developing contact

  16. Endocrinopathies after Allogeneic and Autologous Transplantation of Hematopoietic Stem Cells

    Directory of Open Access Journals (Sweden)

    Francesco Orio

    2014-01-01

    Full Text Available Early and late endocrine disorders are among the most common complications in survivors after hematopoietic allogeneic- (allo- and autologous- (auto- stem cell transplant (HSCT. This review summarizes main endocrine disorders reported in literature and observed in our center as consequence of auto- and allo-HSCT and outlines current options for their management. Gonadal impairment has been found early in approximately two-thirds of auto- and allo-HSCT patients: 90–99% of women and 60–90% of men. Dysfunctions of the hypothalamus-pituitary-growth hormone/insulin growth factor-I axis, hypothalamus-pituitary-thyroid axis, and hypothalamus-pituitary-adrenal axis were documented as later complicances, occurring in about 10, 30, and 40–50% of transplanted patients, respectively. Moreover, overt or subclinical thyroid complications (including persistent low-T3 syndrome, chronic thyroiditis, subclinical hypo- or hyperthyroidism, and thyroid carcinoma, gonadal failure, and adrenal insufficiency may persist many years after HSCT. Our analysis further provides evidence that main recognized risk factors for endocrine complications after HSCT are the underlying disease, previous pretransplant therapies, the age at HSCT, gender, total body irradiation, posttransplant derangement of immune system, and in the allogeneic setting, the presence of graft-versus-host disease requiring prolonged steroid treatment. Early identification of endocrine complications can greatly improve the quality of life of long-term survivors after HSCT.

  17. Anterior Knee Pain (Chondromalacia Patellae).

    Science.gov (United States)

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  18. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  19. A and B mode ultrasonography in preoperative evaluation of lens and posterior segment of dogs eyes with cataract

    Directory of Open Access Journals (Sweden)

    Bianca C. Martins

    2010-02-01

    Full Text Available Ultrasonography of the lens and posterior segment is an indispensable step in the preoperative evaluation of dogs with cataracts, since ophthalmoscopy is not feasible when there is opacification of the lens. This study evaluated the echographic conditions of cataractous lens and fundus of the eye in dogs affected by cataracts. The study was conducted in 30 dogs (56 eyes, 10 males and 20 females, with different types of cataracts at different stages of development. Echography in A and B modes, simultaneously, was carried out for the examination of the lens and posterior segment. The examinations revealed anterior cortical, posterior cortical and nuclear cataract in 12 eyes (21.4%, anterior cortical, posterior cortical, nuclear and posterior capsular in 23 eyes (41%, anterior cortical, posterior cortical and posterior capsular cataract in one eye (1.7%, anterior cortical and nuclear cataract in one eye (1.7%, anterior cortical, nuclear and posterior capsular cataract in five eyes (8.9%, and anterior cortical cataract in seven eyes (12.5%. Abnormal ultrasonographic alterations were observed in the posterior segment in 26 eyes evaluated (46.4%. Vitreal degeneration was detected in 12 eyes (21.4%, images of vitreal exudate or hemorrhage in seven eyes (12.5%, persistence of hyaloid artery in four eyes (7.1% and lens subluxation in three eyes (5.3%. The results obtained reiterate the importance of ultrasonography in canine patients presented for cataract surgery given that alterations of the posterior segment are difficult to identify in a clinical examination when the lens is opacified.A ultrassonografia do segmento posterior do bulbo do olho é etapa indispensável na avaliação de cães com catarata que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Este estudo avaliou as condições ecográficas da lente cataratogênica e do fundo de olho de c

  20. Diffuse anterior retinoblastoma: current concepts

    Directory of Open Access Journals (Sweden)

    Yang J

    2015-07-01

    Full Text Available Jing Yang,1–3 Yalong Dang,1–3 Yu Zhu,1 Chun Zhang2,3 1Department of Ophthalmology, The First Affiliated Hospital, Zhengzhou University, Zhengzhou City, Henan Province, 2Department of Ophthalmology, Peking University Third Hospital, 3Clinical Stem Cell Research Center, Peking University Third Hospital, Beijing, People’s Republic of China Abstract: Diffuse anterior retinoblastoma is a rare variant of retinoblastoma seeding in the area of the vitreous base and anterior chamber. Patients with diffuse anterior retinoblastoma are older than those with the classical types, with the mean age being 6.1 years. The original cells of diffuse anterior retinoblastoma are supposed to be cone precursor. Patients most commonly present with pseudouveitis, pseudohypopyon, and increased intraocular pressure. The retina under fundus examination is likely to be normal, and the clinical features mimic the inflammation progress, which can often lead to misdiagnosis. The published diffuse anterior retinoblastoma cases were diagnosed after fine-needle aspiration biopsy running the potential risk of inducing metastasis. The most common treatment for diffuse anterior retinoblastoma is enucleation followed by systematic chemotherapy according to the patient’s presentation and clinical course. This review summarizes the recent advances in etiology (including tumorigenesis and cell origin, pathology, diagnosis, differential diagnosis, and new treatment. The challenges of early diagnosis and prospects are also discussed. Keywords: pathology, microenvironment, treatment, diagnosis 

  1. Anterior chamber depth during hemodialysis

    Directory of Open Access Journals (Sweden)

    Gracitelli CPB

    2013-08-01

    Full Text Available Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241. We observed a significantly decreased anterior chamber depth (P = 0.002 during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucoma

  2. Paediatric intraocular lens implants: accuracy of lens power calculations.

    Science.gov (United States)

    O'Gallagher, M K; Lagan, M A; Mulholland, C P; Parker, M; McGinnity, G; McLoone, E M

    2016-09-01

    PurposeThis study aims to evaluate the accuracy of lens prediction formulae on a paediatric population.MethodsA retrospective case-note review was undertaken of patients under 8 years old who underwent cataract surgery with primary lens implantation in a regional referral centre for paediatric ophthalmology, excluding those whose procedure was secondary to trauma. Biometric and refractive data were analysed for 43 eyes, including prediction errors (PE). Statistical measures used included mean absolute error (MAE), median absolute error (MedAE), Student's t-test and Lin's correlation coefficient.ResultsThe mean PE using the SRK-II formula was +0.96 D (range -2.47D to +2.41 D, SD 1.33 D, MAE 1.38 D, MedAE 1.55, n=15). The mean PE was smaller using SRK/T (-0.18 D, range -3.25 D to +3.95 D, SD 1.70 D, MAE 1.30 D, MedAE 1.24, n=27). We performed an analysis of the biometry data using four different formula (Hoffer Q, Holladay 1, SRK-II and SRK/T). Hoffer Q showed a smaller MedAE than other formulae but also a myopic bias.ConclusionOur clinical data suggest SRK/T was more accurate in predicting post-operative refraction in this cohort of paediatric patients undergoing cataract surgery. Hoffer Q may have improved accuracy further.

  3. Automated detection of inflammatory cells in whole anterior chamber of a uveitis mouse from swept-source optical coherence tomography images

    Science.gov (United States)

    Choi, Woo June; Pepple, Kathryn L.; Wang, Ruikang K.

    2016-03-01

    Cell grading in a rodent anterior chamber is essential for anterior inflammation evaluation in preclinical vision research. This paper describes a computerized method for detection and counting of the anterior chamber cells from swept-source optical coherence tomography (SS-OCT) images of a experimental rodent model of uveitis. The volumetric anterior segment OCT data is obtained from 100 kHz SS-OCT imaging of mouse eye in vivo. For the OCT cross-sections, each OCT structural image is de-speckled and binarized. After removal of cornea, iris, and crystalline lens structures connected to the binary image border, an area thresholding is then employed for each labeled region to isolate only celllike objects in the anterior chamber, followed by roundness estimation of the objects to identify potential cell candidates in the data. Eventually, the cell candidates are counted and graded as total number of cells in the anterior chamber.

  4. Flat lens for seismic waves

    CERN Document Server

    Brule, Stephane; Guenneau, Sebastien

    2016-01-01

    A prerequisite for achieving seismic invisibility is to demonstrate the ability of civil engineers to control seismic waves with artificially structured soils. We carry out large-scale field tests with a structured soil made of a grid consisting of cylindrical and vertical holes in the ground and a low frequency artificial source (< 10 Hz). This allows the identification of a distribution of energy inside the grid, which can be interpreted as the consequence of an effective negative refraction index. Such a flat lens reminiscent of what Veselago and Pendry envisioned for light opens avenues in seismic metamaterials to counteract the most devastating components of seismic signals.

  5. Atom lens without chromatic aberrations

    CERN Document Server

    Efremov, Maxim A; Schleich, Wolfgang P

    2012-01-01

    We propose a lens for atoms with reduced chromatic aberrations and calculate its focal length and spot size. In our scheme a two-level atom interacts with a near-resonant standing light wave formed by two running waves of slightly different wave vectors, and a far-detuned running wave propagating perpendicular to the standing wave. We show that within the Raman-Nath approximation and for an adiabatically slow atom-light interaction, the phase acquired by the atom is independent of the incident atomic velocity.

  6. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  7. Distinguishing allogenic from autogenic causes of bed elevation change in late Quaternary alluvial stratigraphic records

    Science.gov (United States)

    Daniels, J. Michael

    2008-10-01

    Allogenic and autogenic mechanisms both cause changes in the bed elevation of rivers and thereby influence the characteristics of alluvial stratigraphic records (ASRs). Allogenic forcing mechanisms can be grouped into five categories whose relative influence varies with timescale: climate, tectonism, base level, land use/land cover and direct human modification of channels. Late Quaternary ASRs are influenced by the greatest range of allogenic forcing variables with climate among the most important. Autogenic mechanisms of bed elevation change are ubiquitous throughout fluvial systems and are always time-transgressive. Autogenic bed elevation change propagates through drainage networks at predictable rates and results in a time-space envelope within which its effects are capable of operating. ASRs that can be correlated over geographical areas large enough and time intervals small enough to exist outside this envelope most likely result from allogenic forcing. This formulation represents a quantitative and geographic set of threshold criteria for distinguishing between autogenic and allogenic mechanisms. Over late Quaternary timescales (10 2 to 10 5 years) in tectonically stable regions climate change is the dominant allogenic mechanism and, therefore, the first-order control on the morphology, sedimentology, pedologic characteristics and chronology of alluvial stratigraphic records that meet or exceed the threshold criteria for demonstrating allogenic causality.

  8. Contact lens intolerance: refitting with dual axis lens for corneal refractive therapy

    Science.gov (United States)

    López-López, María; Pelegrín-Sánchez, José Miguel; Sobrado-Calvo, Paloma; García-Ayuso, Diego

    2011-01-01

    Corneal refractive therapy is a non-surgical procedure whose main purpose is to improve uncorrected visual acuity during the day, without spectacles or contact lenses. We report an adult woman who shows contact lens intolerance and does not want to wear eyeglasses. We used dual axis contact lens to improve lens centration. We demonstrate a maintained unaided visual acuity during one year of treatment. In conclusion, we can consider refitting with dual axis lens for corneal refractive therapy as a non-surgical option for patients who show contact lens intolerance.

  9. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  10. Titanium implant insertion into dog alveolar ridges augmented by allogenic material

    DEFF Research Database (Denmark)

    Pinholt, E M; Haanaes, H R; Donath, K

    1994-01-01

    The purpose of this investigation was to evaluate whether titanium endosseous implants would osseointegrate in dog alveolar ridges augmented by allogenic material. In 8 dogs en bloc resection, including 2 pre-molars, was performed bilaterally in the maxilla and the mandible. After a healing period...... of 6 weeks allogenic, demineralized and lyophilized dentin or bone was implanted subperiosteally. Titanium implants were installed 5.5 months later in some of the regions. Light and fluorescence microscopic evaluation revealed fibrous encapsulation of the implanted allogenic material, no osteoinduction...... and only minimal osteoconduction, few multinuclear giant cells and a sparse inflammatory reaction. The titanium implants healed mainly by fibrous encapsulation....

  11. Antitumor immunomodulatory activity of allogenic bone marrow cells on TiNi scaffold

    Science.gov (United States)

    Kokorev, O. V.; Hodorenko, V. N.; Cherdyntseva, N. V.; Gunther, V. E.

    2016-08-01

    The present study was undertaken to evaluate the feasibility of modulation of anti-tumor response by allogenic bone marrow cell transplantation into porous TiNi-based scaffold. Transplantation of bone marrow cells into porous TiNi-based scaffold leads to antitumor (35%) and antimetastatic (55%) effects. The lifetime of tumor-bearing animals and implanted allogenic bone marrow cells in incubator of TiNi increases up to 60%. The possible mechanisms of the effect of allogenic cells on tumor process are the stimulation of endogenous effectors of antitumor immunity.

  12. Plasma Lens for Muon and Neutrino Beams

    Energy Technology Data Exchange (ETDEWEB)

    Kahn,S.A.; Korenev, S.; Bishai, M.; Diwan, M.; Gallardo, J.C.; Hershcovitch, A.; Johnson, B.M.

    2008-06-23

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-energy lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma for optimum focusing. The plasma lens is immersed in an additional solenoid magnetic field to facilitate the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. Plasma lenses have the additional advantage of negligible pion absorption and scattering by the lens material and reduced neutrino contamination during anti-neutrino running. Results of particle simulations using plasma lens will be presented.

  13. Liquid lens using acoustic radiation force.

    Science.gov (United States)

    Koyama, Daisuke; Isago, Ryoichi; Nakamura, Kentaro

    2011-03-01

    A liquid lens is proposed that uses acoustic radiation force with no mechanical moving parts. It consists of a cylindrical acrylic cell filled with two immiscible liquids (degassed water and silicone oil) and a concave ultrasound transducer. The focal point of the transducer is located on the oil-water interface, which functions as a lens. The acoustic radiation force is generated when there is a difference in the acoustic energy densities of different media. An acoustic standing wave was generated in the axial direction of the lens and the variation of the shape of the oil-water interface was observed by optical coherence tomography (OCT). The lens profile can be rapidly changed by varying the acoustic radiation force from the transducer. The kinematic viscosity of silicone oil was optimized to minimize the response times of the lens. Response times of 40 and 80 ms when switching ultrasonic radiation on and off were obtained with a kinematic viscosity of 200 cSt. The path of a laser beam transmitted through the lens was calculated by ray-tracing simulations based on the experimental results obtained by OCT. The transmitted laser beam could be focused by applying an input voltage. The liquid lens could be operated as a variable-focus lens by varying the input voltage.

  14. Metasurface lens: Shrinking the camera size

    Science.gov (United States)

    Sun, Cheng

    2017-01-01

    A miniaturized camera has been developed by integrating a planar metasurface lens doublet with a CMOS image sensor. The metasurface lens doublet corrects the monochromatic aberration and thus delivers nearly diffraction-limited image quality over a wide field of view.

  15. Managing as designing with a positive lens

    NARCIS (Netherlands)

    Avital, M.; Boland, R.J.; Avital, M.; Boland, R.J.; Cooperrider, D.L.

    2007-01-01

    The role and potential contribution of a positive lens to the design of systems and organizations is the focus of this essay. The positive lens refers to an emerging perspective in the social sciences that emphasizes a positive stance toward our capacity to construct better organizations and technol

  16. Optimization of Zoom Lens with Discrete State of Liquid Lens Elements by Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Cheng-Mu Tsai

    2015-01-01

    Full Text Available This paper is to employ liquid lens elements to design a lens with zoom function by using the genetic algorithm (GA optimization. The liquid lens elements used in the proposal can apply voltage adjustment to generate the electrical field that induces the liquid with electric conductivity to vary the surface curvature between two different kinds of liquids. According to the voltage level, the liquid lens element makes the discrete variation of the curvature and thickness realize the zoom function without moving the lens groups so that the overall length can be reduced. However, it is difficult to design the zoom lens under the discrete variation of the curvature and thickness in the liquid lens elements and the mechanical space that is constantly limited. The GA offers a flexible way for lens optimization. We regarded the spot size as the fitness function to look for the optimum curvatures, thickness, and the corresponding statuses of liquid lens elements for the zoom lens. As a result, the zoom lens with constant space can be realized by running the selection, crossover, and mutation operation in the GA optimization.

  17. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    Directory of Open Access Journals (Sweden)

    Giammaria D

    2013-01-01

    Full Text Available Daniele Giammaria,1 Michele Giannotti,2 Angelo Scopelliti,1 Giacomo Pellegrini,1 Bruno Giannotti11Azienda Ospedaliera Ospedali Riuniti Marche Nord, Fano, Italy; 2Catholic University of Rome, Rome, ItalyAbstract: The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances to increase the stability of the anterior chamber and to dose the injected dye have been described. The authors present an under-air staining technique of the anterior capsule using one drop of Trypan blue injected with a 30 G needle through the peripheral cornea. This procedure prevents the air bubble from escaping the anterior chamber and allows fast and selective staining of the capsule.Keywords: Trypan blue, staining technique, dye, cataract surgery, capsulorhexis

  18. The phaco hemi-flip: a method of lens removal in nuclei of soft to moderate density.

    Science.gov (United States)

    Tam, Diamond Y; Ahmed, Iqbal Ike K

    2011-01-01

    Although endocapsular nuclear fragmentation chopping techniques have allowed surgeons to decrease the amount of dissipated phaco energy in the anterior chamber and improve lens removal efficiency when compared with previous techniques, chopping maneuvers carry a small risk of capsular and zonular injury. Furthermore, in softer lenses, chopping techniques may be limited in providing sufficient nuclear cracking. Additionally, with torsional phaco technologies, adequate lens purchase may be suboptimal and lead to inefficient chopping. Supracapsular phaco techniques improve capsular safety, but may be challenging in small pupil/capsulorrhexis cases and place the corneal endothelium and anterior chamber tissues at greater risk to trauma from ultrasound energy. The phaco hemi-flip technique combines the advantages of these two approaches with a single endocapsular quick chop, followed by phacoaspiration removal of each heminucleus in the iris plane without further chopping or segmentation.

  19. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type

  20. Bacterial assay of contact lens wearers.

    Science.gov (United States)

    Hart, D E; Hosmer, M; Georgescu, M; Farris, R L

    1996-03-01

    The goal of the project was to determine the quantity of bacteria on the contact lens and adjacent areas of the eye. This paper is a quantitative study of the contact lens and ocular aerobic microbiota in a mixed group of daily and extended wear disposable contact lens users. The contact lens, the lower fornix, tears collecting at the lower fornix, and edge of the lower lid at the Meibomian gland margin were assayed for the quantity of bacterial colony forming units (CFU). Eighteen patients wearing 49 disposable high water content hydrogel contact lenses were assayed and the mean lens age was 8.8 +/- 4.6 days. Three patients wore their lenses on a daily wear basis and 15 on an extended wear schedule. Tear samples were obtained with sterile microbial loops and the lens was macerated into small particles with a tissue grinder. The samples were poured onto the surface of chocolate agar plates and incubated at 35 degrees C for 48 h in 5% Co2. The lid margin revealed the greatest bacterial presence (mean = 9.7 CFU; median = 2 CFU; mode = 0 CFU). The lens showed the next greatest presence of CFU (mean = 4.5 CFU; median = 1 CFU; mode = 0). The fornix and tears revealed the least bacterial presence (fornix: mean = 2.6 CFU; median = 0 CFU; mode = 0 CFU). The bacteria were coagulase-negative staphylococci. The bacterial assay of disposable lens wearing contact lens subjects indicates that the lid margins are the greatest source of bacteria with the tears being the lowest. These studies support the concept that in the eye, the lens typically does not possess a large number of bacteria under normal conditions.

  1. Visual outcomes after anterior vitrectomy: comparison of ECCE and phacoemulsification.

    Science.gov (United States)

    Bobrow, J C

    1999-01-01

    To determine whether vitrectomy instrumentation improved outcomes when vitreous loss occurred during either extracapsular cataract extraction (ECCE) or phacoemulsification (PE) with posterior chamber lens implantation (PCIOL). A consecutive series of ECCE + PCIOL (group 1: 1985-1989) and PE + PCIOL (group 2: 1993-1997) surgeries by a single surgeon was reviewed retrospectively. In group 1, 14 of 647 patients (2.2%) and in group 2, 9 of 665 patients (1.4%) experienced vitreous loss. In group 1, final visual acuity averaged 20/83; in group 2, 20/25 (P = .005). Average follow-up was 5.7 years (group 1) and 3.2 years (group 2). Uveitis, glaucoma, corneal problems, and retinal problems were assessed. Anterior vitrectomy reduced complications from vitreous loss. Fewer vitreous losses occurred with PE than ECCE. Patients with vitreous loss after PE attained better vision.

  2. In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy

    Directory of Open Access Journals (Sweden)

    Ahmed Mohamed Kamal Elshafei

    2016-01-01

    Full Text Available Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL, and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM. Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the adjacent structure and the overall iris configuration were evaluated. The machine calibers were used to measure the minimum central distance between the ICL and anterior lens capsule (vault and the vertical central distance between the corneal endothelium and the ICL (E-ICL. Results. The mean ICL vault was 376±105 μm. The mean E-ICL was 2826±331 μm. Contact between ICL and the posterior epithelium of the iris was present in all eyes. The overall iris configuration was flat in 89 eyes. Central anterior convexity was present in 41 eyes and mild peripheral iris bombe in 12 eyes. The haptics could be imaged in the ciliary sulcus in 112 eyes and at least one haptic resting on the lens periphery and zonules in 30 eyes. Conclusion. UBM can provide valuable anatomical information that allows detailed postoperative in vivo assessment of ICL.

  3. In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy

    Science.gov (United States)

    Genaidy, Mahmoud Mohamed; Moharram, Hossam Mohamed

    2016-01-01

    Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL), and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM). Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the adjacent structure and the overall iris configuration were evaluated. The machine calibers were used to measure the minimum central distance between the ICL and anterior lens capsule (vault) and the vertical central distance between the corneal endothelium and the ICL (E-ICL). Results. The mean ICL vault was 376 ± 105 μm. The mean E-ICL was 2826 ± 331 μm. Contact between ICL and the posterior epithelium of the iris was present in all eyes. The overall iris configuration was flat in 89 eyes. Central anterior convexity was present in 41 eyes and mild peripheral iris bombe in 12 eyes. The haptics could be imaged in the ciliary sulcus in 112 eyes and at least one haptic resting on the lens periphery and zonules in 30 eyes. Conclusion. UBM can provide valuable anatomical information that allows detailed postoperative in vivo assessment of ICL. PMID:27672446

  4. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    Science.gov (United States)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  5. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  6. The Role of Type IV Collagen in Developing Lens in Mouse Fetuses

    Directory of Open Access Journals (Sweden)

    Mehdi Jalali

    2009-09-01

    Full Text Available Objective(sExtracellular matrix (ECM and basement membrane (BM play important roles in many developmental processes during development and after birth. Among the components of the BM, collagen fibers specially type IV are the most important parts. The aim of this study was to determine the time when collagen type IV appears in the BM of lens structure during mouse embryonic development.Materials and MethodsIn this experimental study, 22 female Balb/C mice were randomly selected and were kept under normal condition, finding vaginal plug was assumed as day zero of pregnancy. From embryonic day 10 to 20, all specimens were sacrificed by cervical dislocation and their heads were fixed, serially sectioned and immunohistochemistry study for tracing collagen type IV in lens were carried out.ResultsOur data revealed that collagen type IV appeared at the early stage of gestation day 12 in BM of anterior epithelial lens cells and the amount of this protein gradually increased until days 15-17 in ECM and posterior capsule epithelium. After this period, severe reaction was not observed in any part of the lens.ConclusionThese findings establish the important role of collagen IV in developing optic cup and any changes during critical period of pregnancy may be result in severe visual system defect

  7. Zebrafish mutations in Gli-mediated hedgehog signaling lead to lens transdifferentiation from the adenohypophysis anlage.

    Science.gov (United States)

    Kondoh, H; Uchikawa, M; Yoda, H; Takeda, H; Furutani-Seiki, M; Karlstrom, R O

    2000-09-01

    It is known that the earliest lens marker delta-crystallin is expressed abundantly in Rathke's pouch of the chicken, suggesting a close relationship between the cell states of the adenohypophysis (pituitary) anlage and the early lens. We show here that the zebrafish midline mutants you-too (yot) and iguana (igu) develop lenses from the adenohypophysis anlage. The early adenohypophysis anlage of normal zebrafish expresses lim3 and six3 but in yot(ty119) mutants the anterior part of the anlage lacks lim3 expression, and instead produces a crystallin-expressing cell population which develops into a large lens structure expressing beta and gamma-crystallins, but is not associated with retina tissues. Among the zebrafish mutants with midline defects, midline lenses were observed in two mutant alleles of yot and an allele of igu, but not in other mutants (syu, con, smh, dtr, uml, spi and lok). Two yot mutant alleles with midline lenses likely encode dominant negative forms of the Gli2 protein which will interfere with transcriptional activation by other Gli proteins. The observation argues that overall inhibition of Shh-Gli signaling leads the adenohypophysis anlage to transdifferentiate into lens.

  8. Chlamydia pneumoniae respiratory infection after allogeneic stem cell transplantation.

    Science.gov (United States)

    Geisler, William M; Corey, Lawrence

    2002-03-27

    Chlamydia pneumoniae is a common cause of upper and lower respiratory tract infections in immunocompetent patients; however, its role as a respiratory pathogen in immunocompromised hosts has been infrequently recognized. We describe C. pneumoniae lower respiratory tract infection in a 19-year-old male after allogeneic stem cell transplantation. The patient developed fever on day +14, and a subsequent computed tomography scan of the chest revealed a right lateral pleural-based opacity, which was then resected during thoracoscopy. Diagnosis was made by culture and staining of the resected tissue with C. pneumoniae-specific monoclonal antibodies, and azithromycin was administered. To the best of our knowledge, this is the first report of C. pneumoniae respiratory infection after stem cell or marrow transplantation. C. pneumoniae often coexists with other etiologic agents of pneumonia in immunocompromised patients. Considering the infrequency of infections from this organism in this clinical setting, one must still rule out other more likely respiratory pathogens.

  9. Sexual function 1-year after allogeneic hematopoietic stem cell transplantation

    DEFF Research Database (Denmark)

    Noerskov, K. H.; Schjødt, I.; Syrjala, K. L.

    2016-01-01

    Treatment with allogeneic hematopoietic stem cell transplantation (HSCT) is associated with short and long-term toxicities that can result in alterations in sexual functioning. The aims of this prospective evaluation were to determine: (1) associations between HSCT and increased sexual dysfunction......). Assessment included descriptive data, Sexual Functioning Questionnaire, Body Image Scale and Hospital Anxiety and Depression Scale. The results showed a significant decline in overall sexual function in both men and women (P=.... Forty-seven percent of men and 60% of women reported at least one physical sexual problem 1 year after HSCT. Patients with chronic GVHD trended toward reporting lower levels of sexual function. Finally, women with chronic GVHD scored lower than those without chronic GVHD on the sexual function problem...

  10. Allogeneic transplantation in the UK: an aggregation of marginal gains?

    Science.gov (United States)

    Thomson, Kirsty J; Peggs, Karl S

    2013-10-01

    A number of advances in clinical practice that are considered routine in modern allogeneic transplant programmes lack definitive supporting evidence, partly because they may offer modest incremental benefits that are difficult to demonstrate in a statistically robust manner given the relatively small cohorts of patients who undergo such procedures. Nevertheless, these marginal gains probably contribute therapeutically meaningful overall benefit, particularly when aggregated. We review the evidence for a number of these practices in terms of impact on transplant outcomes, with particular reference to the setting of T cell depletion as widely practiced in the United Kingdom, including high resolution tissue typing, surveillance for and therapy of infectious complications, chimerism-directed immune modulation and more sensitive monitoring for residual or progressive disease.

  11. Allogeneic cell therapy bioprocess economics and optimization: downstream processing decisions.

    Science.gov (United States)

    Hassan, Sally; Simaria, Ana S; Varadaraju, Hemanthram; Gupta, Siddharth; Warren, Kim; Farid, Suzanne S

    2015-01-01

    To develop a decisional tool to identify the most cost effective process flowsheets for allogeneic cell therapies across a range of production scales. A bioprocess economics and optimization tool was built to assess competing cell expansion and downstream processing (DSP) technologies. Tangential flow filtration was generally more cost-effective for the lower cells/lot achieved in planar technologies and fluidized bed centrifugation became the only feasible option for handling large bioreactor outputs. DSP bottlenecks were observed at large commercial lot sizes requiring multiple large bioreactors. The DSP contribution to the cost of goods/dose ranged between 20-55%, and 50-80% for planar and bioreactor flowsheets, respectively. This analysis can facilitate early decision-making during process development.

  12. A Unique Case of Allogeneic Fat Grafting Between Brothers

    Science.gov (United States)

    Kim, Samuel; Edelson, Richard L.; Sumpio, Brandon; Kwei, Stephanie

    2016-01-01

    Summary: We present a case of a 65-year-old man with cutaneous T-cell lymphoma treated with radiation therapy and an allogeneic hematopoietic stem cell transplant from his human leukocyte antigen-matched brother. Engraftment was successful, but the patient went on to develop painful, radiation-induced ulcers. The ulcers were fat-allografted using liposuctioned fat from his brother because of the patient’s unique chimeric state. Postprocedure follow-up revealed epithelialization of the ulcer sites and significant improvement in neuropathic pain. Our unique case study supports the use of fat grafting for its restorative purposes and for its ability to alleviate chronic neuropathic pain. Additionally, it appears that our case provides a basis of a general approach to the treatment of radiation-induced ulcers in chimeric patients with lymphoid malignancies.

  13. Allogeneic Mesenchymal Stem Cell Transplantation in Dogs With Keratoconjunctivitis Sicca

    Science.gov (United States)

    Bittencourt, Maura K. W.; Barros, Michele A.; Martins, João Flávio P.; Vasconcellos, Jose Paulo C.; Morais, Bruna P.; Pompeia, Celine; Bittencourt, Matheus Domingues; Evangelho, Karine dos Santos; Kerkis, Irina; Wenceslau, Cristiane V.

    2016-01-01

    Keratoconjunctivitis sicca (KCS) is a dysfunction in tear production associated with clinical signs, which include conjunctival hyperemia, ocular discharge, discomfort, pain, and, eventually, corneal vascularization and pigmentation. Immunosuppressive drugs are routinely administrated for long periods to treat KCS but with side effects and limited results. Evaluation of the clinical benefits of intralacrimal transplantation of allogeneic mesenchymal stem cells (MSCs) in dogs with mild–moderate and severe KCS was done. A total of 24 eyes with KCS from 15 dogs of different breeds were enrolled in the present study. A single transplantation of MSCs (1 × 106) directly into lacrimal glands (dorsal and third eyelid) was performed. The Schirmer tear tests (STTs) and ocular surface improvements were used to assess short- and long-term effects of these cells. The STTs were carried out on day 0 (before MSCs transplantation) and on days 7, 14, 21, and 28, as well as 6 and 12 months after MSC transplantation. Our data demonstrate that allogeneic MSC transplantation in KCS dogs is safe since no adverse effects were observed immediately after transplantation and in short- and long-term follow-ups. A statistically significant increase in the STT and ocular surface improvements was found in all eyes studied. In all the eyes with mild–moderate KCS, STT values reverted to those of healthy eyes, while in eyes with severe KCS, although complete reversion was not found, there was improvement in tear production and in other clinical signs. Our study shows that a single dose of a low number of MSCs can be used to treat KCS in dogs. In contrast to immunosuppressive drug use, MSC transplantation has an effect over a long period (up to 12 months), even after a single administration, and does not require daily drug administration. PMID:28003932

  14. Allogeneic hematopoietic stem cell transplantation in children with aplastic anemia.

    Science.gov (United States)

    Xue, H-M; Xu, H-G; Huang, K; Guo, H-X; Li, Y; Zhou, D-H; Huang, S-L; Fang, J-P; Chen, C

    2015-05-18

    The aim of this study was to prospectively investigate the efficacy and safety of fully matched allogeneic hematopoietic stem cell transplants in children with severe aplastic anemia in China. A total of twenty patients with severe aplastic anemia were enrolled in our study. Thirteen cases underwent transplantation with fully human leukocyte antigen (HLA)-matched, granulocyte-colony stimulating factor (G-CSF)-primed bone marrow and peripheral blood stem cells (PBSCs) from matching sibling donors. One patient received fully HLA-matched bone marrow from an unrelated donor. Six patients received fully HLA-matched G-CSF-primed PBSCs from unrelated donors. The conditioning regimen included fludarabine, cyclophosphamide, and rabbit anti-thymocyte globulin. Graft-versus-host disease prophylaxis was conducted with cyclosporin A and short-course methotrexate. The median follow-up duration was 3.08 years (range, 0.83-8.41years). The median time of neutrophil recovery (>0.5 x 10(9)/L) was 14 days (range, 10-20 days), and the median time of platelet recovery (>20 x 10(9)/L) was 19 days (range, 14-31 days). The survival rate at the cutoff point of follow-up was 95.0% (19/20). Initial engraftment rate was 95% (19/20). Late graft failure (graft failures occurring 1 year or longer after transplantation) was observed in one patient. Only one patient developed Grade I acute graft-versus-host disease. Two cases suffered from Epstein- Barr virus (EBV)-associated post-transplant lymphoproliferative disorder and remitted after treatment with rituximab. One patient was diagnosed with hyperthyroidism 2.5 years after transplantation. Our study indicated that allogeneic hematopoietic stem cell transplantation is an effective and safe treatment for children with severe aplastic anemia in China.

  15. Pulpal regeneration following allogenic tooth transplantation into mouse maxilla.

    Science.gov (United States)

    Unno, Hideki; Suzuki, Hironobu; Nakakura-Ohshima, Kuniko; Jung, Han-Sung; Ohshima, Hayato

    2009-04-01

    Autogenic tooth transplantation is now a common procedure in dentistry for replacing a missing tooth. However, there are many difficulties in clinical application of allogenic tooth transplantation because of immunological rejection. This study aims to clarify pulpal regeneration following allogenic tooth transplantation into the mouse maxilla by immunohistochemistry for 5-bromo-2'-deoxyuridine (BrdU) and nestin, and by the histochemistry for tartrate-resistant acid phosphatase (TRAP). The upper right first molar (M1) of 2-week-old mice was extracted and allografted in the original socket in both the littermate and non-littermate after the extraction of M1. Tooth transplantation weakened the nestin-positive reactions in the pulp tissue that had shown immunoreactivity for nestin before operation. On postoperative Days 5-7, tertiary dentin formation commenced next to the preexisting dentin where nestin-positive odontoblast-like cells were arranged in all cases of the littermate group until Day 14, except for one case showing immunological rejection in the pulp chamber. In the non-littermate group, bone-like tissue formation occurred in the pulp chamber in addition to tertiary dentin formation until Day 14. The rate of tertiary dentin was 38%, and the rate of the mixed form of dentin and bone-like tissue formation was 23% (the remainder was immunological rejection). Interestingly, the periodontal tissue recovered even in the case of immunological rejection in which the pulp chamber was replaced by sparse connective tissue. These results suggest that the selection of littermate or non-littermate is decisive for the survival of odontoblast-lineage cells and that the immunological rejection does not influence the periodontal regeneration.

  16. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    Pei Cheng; Sun Naixue

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was implanted in the capsular bag for the experimental eyes and controls respectively. After the operation, anterior chamber reaction, intraocular pressure (IOP) and CsA concentration were monitored and twelve weeks after the operation, the eyes were extracted for histopathological and morphological examinations. Results There were no differences between the two groups in conjunctival congestion,IOP change and anterior chamber reaction. PCO was less severe in the experimental eyes than in the controls. Light microscopy revealed that posterior capsular membrane in the experimental eyes was slick, with no obvious proliferation,whereas in the controls, there were lens epithelial cell proliferation and cortex regeneration of different degrees.Morphological examination with electron microscope showed that in the experimental eyes, lens epithelial cells did not function actively and apoptosis occurred, whereas in the controls, epithelial cells presented active function. No marked ultrastructural changes were found in either group. Conclusion Cs-DDS can inhibit PCO after intraocular lens implantation in rabbit eyes and does not have toxic effects on the surrounding ocular tissues. Therefore, it has a good potential for clinical use in prevention of PCO.

  17. Socially disadvantaged parents of children treated with allogeneic haematopoietic stem cell transplantation (HSCT)

    DEFF Research Database (Denmark)

    Larsen, Hanne Bækgaard; Heilmann, Carsten; Johansen, Christoffer

    2013-01-01

    PURPOSE: This study was undertaken to test a daily Family Navigator Nurse (FNN) conducted intervention program, to support parents during the distressful experience of their child's Allogeneic Haematopoietic Stem Cell Transplantation (HSCT). METHODS: A qualitative analysis of the supportive...

  18. Comparison of immune reconstitution after allogeneic vs. autologous stem cell transplantation in 182 pediatric recipients

    Directory of Open Access Journals (Sweden)

    V. Wiegering

    2017-03-01

    Conclusion: Children undergoing a HSCT show a different pattern of immune reconstitution in the allogeneic and autologous setting. This might influence the outcome and should affect the clinical handling of infectious prophylaxis and re-vaccinations.

  19. Allogeneic hematopoietic stem cell transplantation for chronic myelomonocytic leukemia:a report of 12 patients

    Institute of Scientific and Technical Information of China (English)

    孙于谦

    2013-01-01

    Objective To retrospectively review the efficacy of allogeneic hematopoietic stem cell transplantation(allo-HSCT)for chronic myelomonocytic leukemia(CMML).Methods The engraftment,graft versus host disease(GVHD)

  20. The risks of using allogeneic cell lines for vaccine production: the example of Bovine Neonatal Pancytopenia.

    Science.gov (United States)

    Benedictus, Lindert; Bell, Charlotte R

    2017-01-01

    Bovine neonatal pancytopenia (BNP) is a hemorrhagic disease that emerged in calves across Europe in 2007. Its occurrence is attributed to immunization of the calf's mother with a vaccine produced using an allogeneic cell line. Vaccine-induced alloantibodies specific for major-histocompatibility class I antigens are transferred from the mother to the calf via colostrum, leading to profound depletion of peripheral blood and bone marrow cells that is often fatal. Areas covered: Pubmed and Web of Science were used to search for literature relevant to BNP and the use of allogeneic vaccine cell lines. Following a review of the pathology and pathogenesis of this novel condition, we discuss potential risks associated with the use of allogeneic vaccine cell lines. Expert commentary: Although BNP is associated with a specific vaccine, it highlights safety concerns common to all vaccines produced using allogeneic cell lines. Measures to prevent similar vaccine-induced alloimmune-mediated adverse events in the future are discussed.

  1. Differential effect of conditioning regimens on cytokine responses during allogeneic stem cell transplantation

    DEFF Research Database (Denmark)

    Andersen, J; Heilmann, C; Jacobsen, N

    2006-01-01

    The purpose of this study was to characterize cytokine responses during conditioning in patients undergoing allogeneic stem cell transplantation (SCT) with the aim to identify which markers that may reliably reflect inflammatory activity during conditioning. We investigated inflammatory and anti-...

  2. Calcification of a hydrophilic acrylic intraocular lens: case report with laboratory analysis.

    Science.gov (United States)

    Bodnar, Z M; Rozot, P; Leishman, L; Ollerton, A; Michelson, J; Plasse-Fauque, S; Werner, L

    2013-09-01

    We analyzed a single-piece plate-type hydrophilic acrylic posterior chamber intraocular lens (IOL) that was explanted due to a progressive loss of vision, which occurred 6 years after uncomplicated phacoemulsification. Gross and light microscopy, as well as anterior segment optical coherence tomography (OCT) revealed granular deposits below the IOL surface. Light scattering, as measured with Scheimpflug photography and densitometry analyses was found to be increased; spectrophotometry demonstrated a decrease in the light transmittance of the explanted lens. The granular deposits within the IOL material were found to be composed of calcium by histochemical methods (alizarin red and Von Kossa stains). To our knowledge this is the only report of calcification of this IOL design. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. An atypical presentation of Acanthamoeba keratitis in a noncontact lens wearer.

    Science.gov (United States)

    Speer, Christine E; Hofmeister, Elizabeth M; Cohen, Elisabeth J

    2003-01-01

    This article presents the case of a 49-year-old man who did not have a history of wearing contact lenses and who developed a rapidly progressive course of Acanthamoeba keratitis. The patient developed stromal keratitis that did not respond to herpes simplex virus therapies. Within 1 week after presentation, the patient progressed from mild anterior stromal haze and edema to a ring infiltrate, epithelial loss, and significant corneal edema. Corneal scrapings demonstrated cysts consistent with Acanthanmoeba keratitis. The patient was admitted to the hospital and placed on intensive medical therapy. He responded to therapy, and at 5 months showed central scarring in a quiet eye. This article presents a case of Acanthamoeba keratitis in a non-contact lens wearer, who was diagnosed clinically and histopathologically within 1 week of onset of symptoms. His case was atypical given his lack of contact lens wear or antecedent trauma and rapid progression to a ring infiltrate, usually seen as late findings.

  4. Pars plana vitrectomy with posterior iris claw implantation for posteriorly dislocated nucleus and intraocular lens

    Directory of Open Access Journals (Sweden)

    Kishor B Patil

    2011-01-01

    Full Text Available We evaluated the safety and efficacy of pars plana vitrectomy (PPV with primary posterior iris claw intraocular lens (IOL implantation in cases of posterior dislocation of nucleus and IOL without capsular support. This was a retrospective interventional case series. Fifteen eyes underwent PPV with primary posterior iris claw IOL implantation performed by a single vitreoretinal surgeon. The main outcome measures were changes in best corrected visual acuity and anterior and posterior segment complications. A total of 15 eyes were included in this study. Eight had nucleus drop, three had IOL drop during cataract surgery and four had traumatic posterior dislocation of lens. The final postoperative best corrected visual acuity was 20/60 or better in 11 patients. This procedure is a viable option in achieving good functional visual acuity in eyes without capsular support.

  5. Activated allogeneic NK cells preferentially kill poor prognosis B-cell chronic lymphocytic leukemia cells

    OpenAIRE

    2016-01-01

    Mutational status of TP53 together with expression of wild type (wt) IGHV represents the most widely accepted biomarkers, establishing a very poor prognosis in B-cell chronic lymphocytic leukemia (B-CLL) patients. Adoptive cell therapy using allogeneic HLA mismatched Natural Killer (NK) cells has emerged as an effective and safe alternative in the treatment of acute myeloid and lymphoid leukemias that do not respond to traditional therapies. We have described that allogeneic activated NK cell...

  6. Isolated extra-medullary relapse of acute leukemia following allogeneic bone marrow transplantation.

    Science.gov (United States)

    Firas, Al Sabty; Demeckova, E; Bojtarova, E; Czako, B; Hrubisko, M; Mistrik, M

    2008-01-01

    Isolated extramedullary relapse (IEMR) of acute leukemia (AL) after allogeneic bone marrow transplantation (BMT) is a rare occurrence. It is seen more commonly after BMT than after conventional chemotherapy (CHT) alone. We describe the natural history and response to treatment in four patients with IEMR following allogeneic BMT. The results indicate a stronger graft-versus-leukemia (GVL) effect in the marrow than in the peripheral tissues (Fig. 4, Ref. 13). Full Text (Free, PDF) www.bmj.sk.

  7. The Role of Cortical Plasticity in Recovery of Function Following Allogeneic Hand Transplantation

    Science.gov (United States)

    2016-10-01

    AWARD NUMBER: W81XWH-13-1-0496 TITLE: The Role of Cortical Plasticity in Recovery of Function Following Allogeneic Hand Transplantation ...TITLE AND SUBTITLE The Role of Cortical Plasticity in Recovery of Function Following Allogeneic Hand Transplantation 5a. CONTRACT NUMBER W81XWH-13-1-0496...significant progress on data collection in our multi-day protocol. Our preliminary findings continue to indicate that: 1) Hand transplant recipients

  8. Chemically extracted acellular allogeneic nerve graft combined with ciliary neurotrophic factor promotes sciatic nerve repair

    Institute of Scientific and Technical Information of China (English)

    Yanru Zhang; Hui Zhang; Kaka Katiella; Wenhua Huang

    2014-01-01

    A chemically extracted acellular allogeneic nerve graft can reduce postoperative immune re-jection, similar to an autologous nerve graft, and can guide neural regeneration. However, it remains poorly understood whether a chemically extracted acellular allogeneic nerve graft combined with neurotrophic factors provides a good local environment for neural regenera-tion. This study investigated the repair of injured rat sciatic nerve using a chemically extracted acellular allogeneic nerve graft combined with ciliary neurotrophic factor. An autologous nerve anastomosis group and a chemical acellular allogeneic nerve bridging group were prepared as controls. At 8 weeks after repair, sciatic functional index, evoked potential amplitude of the soleus muscle, triceps wet weight recovery rate, total number of myelinated nerve fibers and myelin sheath thickness were measured. For these indices, values in the three groups showed the autologous nerve anastomosis group > chemically extracted acellular nerve graft + ciliary neurotrophic factor group > chemical acellular allogeneic nerve bridging group. These results suggest that chemically extracted acellular nerve grafts combined with ciliary neurotrophic factor can repair sciatic nerve defects, and that this repair is inferior to autologous nerve anasto-mosis, but superior to chemically extracted acellular allogeneic nerve bridging alone.

  9. Low levels of allogeneic but not syngeneic hematopoietic chimerism reverse autoimmune insulitis in prediabetic NOD mice.

    Science.gov (United States)

    Kaminitz, Ayelet; Mizrahi, Keren; Yaniv, Isaac; Farkas, Daniel L; Stein, Jerry; Askenasy, Nadir

    2009-09-01

    The relative efficiencies of allogeneic and syngeneic bone marrow transplantation and the threshold levels of donor chimerism required to control autoimmune insulitis were evaluated in prediabetic NOD mice. Male and female NOD mice were conditioned by radiation and grafted with bone marrow cells from allogeneic and syngeneic sex-mismatched donors. Establishment of full allogeneic chimerism in peripheral blood reversed insulitis and restored glucose tolerance despite persistence of residual host immune cells. By contrast, sublethal total body irradiation (with or without syngeneic transplant) reduced the incidence and delayed the onset of diabetes. The latter pattern was also seen in mice that rejected the bone marrow allografts. Low levels of stable allogeneic hematopoietic chimerism (>1%) were sufficient to prevent the evolution of diabetes following allogeneic transplantation. The data indicate that immunomodulation attained at low levels of allogeneic, but not syngeneic, hematopoietic chimerism is effective in resolution of islet inflammation at even relatively late stages in the evolution of the prediabetic state in a preclinical model. However, our data question the efficacy and rationale behind syngeneic (autologous-like) immuno-hematopoietic reconstitution in type 1 diabetes.

  10. Ocular Coherence Tomography in the Evaluation of Anterior Eye Injuries in Space Flight

    Science.gov (United States)

    Fer, Dan M.; Law, Jennifer; Wells, Julia

    2017-01-01

    While Ocular Coherence Tomography (OCT) is not a first-line modality to evaluate anterior eye structures terrestrially, it is a resource already available on the International Space Station (ISS) that can be used in medical contingencies that involve the anterior eye. With remote guidance and subject matter expert (SME) support from the ground, a minimally trained crewmember can now use OCT to evaluate anterior eye pathologies on orbit. OCT utilizes low-coherence interferometry to produce detailed cross-sectional and 3D images of the eye in real time. Terrestrially, it has been used to evaluate macular pathologies and glaucoma. Since 2013, OCT has been used onboard the ISS as one part of a suite of hardware to evaluate the Visual Impairment/Intracranial Pressure risk faced by astronauts, specifically assessing changes in the retina and choroid during space flight. The Anterior Segment Module (ASM), an add-on lens, was also flown for research studies, providing an opportunity to evaluate the anterior eye in real time if clinically indicated. Anterior eye pathologies that could be evaluated using OCT were identified. These included corneal abrasions and ulcers, scleritis, and acute angle closure glaucoma. A remote guider script was written to provide ground specialists with step-by-step instructions to guide ISS crewmembers, who do not get trained on the ASM, to evaluate the anterior eye. The instructions were tested on novice subjects and/or operators, whose feedback was incorporated iteratively. The final remote guider script was reviewed by SME optometrists and NASA flight surgeons. The novel application of OCT technology to space flight allows for the acquisition of objective data to diagnose anterior eye pathologies when other modalities are not available. This demonstrates the versatility of OCT and highlights the advantages of using existing hardware and remote guidance skills to expand clinical capabilities in space flight.

  11. Conjugate metamaterials and the perfect lens

    CERN Document Server

    Xu, Yadong; Xu, Lin; Chen, Huanyang

    2015-01-01

    In this letter, we show how transformation optics makes it possible to design what we call conjugate metamaterials. We show that these materials can also serve as substrates for making a subwavelength-resolution lens. The so-called "perfect lens", which is a lens that could focus all components of light (including propagating and evanescent waves), can be regarded as a limiting case, in which the respective conjugate metamaterials approach the characteristics of left-handed metamaterials, which have a negative refractive index.

  12. PMMA lens with high efficiency and reliability

    Science.gov (United States)

    Matsuzaki, Ichiro; Abe, Koji; Fujita, Katsuhiro

    2013-09-01

    Polymethyl Methacrylate (PMMA) Fresnel lenses are increasingly being used in concentrated photovoltaic (CPV) systems installed outdoors and, accordingly, emphasis is being placed on the durability of such lenses with regard to light transmittance when subject to ultraviolet (UV) light and dust exposure. Accelerated testing methods for evaluating durability under UV exposure were established, allowing development of a lens material with improved UV resistance. Simultaneously, through a proprietary molding method, a Fresnel lens that boasts favorable light concentration efficiency with little deformation even after prolonged outdoor use was developed. Moreover, the lens incorporates a new hard-coat finish that possesses sand durability and UV resistance comparable to that of tempered glass.

  13. Anterior cruciate ligament - updating article

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius Malheiros Luzo

    2016-08-01

    Full Text Available ABSTRACT This updating article on the anterior cruciate ligament (ACL has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques.

  14. Anterior cruciate ligament - updating article.

    Science.gov (United States)

    Luzo, Marcus Vinicius Malheiros; Franciozi, Carlos Eduardo da Silveira; Rezende, Fernando Cury; Gracitelli, Guilherme Conforto; Debieux, Pedro; Cohen, Moisés

    2016-01-01

    This updating article on the anterior cruciate ligament (ACL) has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques.

  15. Posterior capsular opacification and intraocular lens decentration. Part I: Comparison of various posterior chamber lens designs implanted in the rabbit model.

    Science.gov (United States)

    Hansen, S O; Solomon, K D; McKnight, G T; Wilbrandt, T H; Gwin, T D; O'Morchoe, D J; Tetz, M R; Apple, D J

    1988-11-01

    Experimental phacoemulsification procedures were performed in 54 Rex rabbits. In 96 eyes, posterior chamber intraocular lenses (IOLs) were implanted in the capsular sac, and 12 eyes served as controls with no lens implantation. The IOLs were divided into eight groups consisting of both one-piece and three-piece styles with various optic designs. Each lens was evaluated for the relative effect on posterior capsular opacification (PCO) and optic decentration, two of the most common complications of modern cataract surgery and IOL implantation. Optics with a convex-anterior, plano-posterior design (the type of IOL optic most frequently implanted today) had the highest incidence of PCO. With capsular fixated IOLs, the features that have a statistically significant impact on reducing PCO include (1) one-piece, all-polymethylmethacrylate (PMMA) IOL styles, (2) a biconvex or posterior convex optic design, and (3) angulated loops. Lens decentration was not affected by the optic design, but statistical analysis showed that one-piece, all-PMMA IOL construction provided the most consistent centration.

  16. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  17. Update and clinical utility of the LenSx femtosecond laser in cataract surgery

    Science.gov (United States)

    Roberts, Timothy V; Lawless, Michael; Sutton, Gerard; Hodge, Chris

    2016-01-01

    The introduction of femtosecond lasers to cataract surgery has been the major disruptive technology introduced into ophthalmic surgery in the last decade. Femtosecond laser cataract surgery (FLACS) integrates high-resolution anterior segment imaging with a femtosecond laser allowing key steps of cataract surgery to be performed with computer-guided laser accuracy, precision, and reproducibility. Since the introduction of FLACS, there have been significant advances in laser software and hardware as well as surgeon experience, with over 250 articles published in the peer-reviewed literature. This review examines the published evidence relating to the LenSx platform and discusses surgical techniques, indications, safety, and clinical results.

  18. Fragmatome lifting: surgical option for intraocular lens and foreign body removal.

    Science.gov (United States)

    Jorge, Rodrigo; Siqueira, Rubens C; Cardillo, José A; Costa, Rogério A

    2005-01-01

    A new technique for intraocular lens (IOL) and foreign body removal using the fragmatome is described. Removal of the formed vitreous, including cortical vitreous, was performed using a conventional vitrectomy probe. The fragmatome tip was placed on the center of the anterior surface of both the IOL optics and the foreign bodies, and active 250 mm Hg vacuum suction was applied. IOLs and foreign bodies were easily held and manipulated after being aspirated into the fragmatome tip, avoiding the use of a forceps or other grasping instrument that may damage the retina. Fragmatome lifting is a reasonable treatment option for IOL and nonmagnetic foreign body removal.

  19. The Clinical Analysis of Secondary Glaucoma Following Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    We present 14 patients with secondary gluacoma following the implantation of a posterior chamber intraocular lens (lOLs). All patients were u-nilateral gluacoma , which developed within 1 month following the IOL implantation in 10 cases, and from 1 to 3 years in 4 cases. The angle of anterior chamber was open in 8 patients, and close in 6 ones. Seven patients required treatment of antiglaucomatous medicine; 4 patients underwent laser indecto-my and 3 patients required antiglaucoma surgery. The results s...

  20. Válvula de uretra anterior Anterior urethral valves

    Directory of Open Access Journals (Sweden)

    Silvio Tucci Jr.

    2003-02-01

    Full Text Available Objetivo: apresentar os aspectos clínicos, diagnósticos e terapêuticos de pacientes portadores de válvula da uretra anterior. Descrição: em dois neonatos, o diagnóstico presuntivo de patologia obstrutiva do trato urinário foi sugerido pela ultra-sonografia realizada no período pré-natal, confirmando-se o diagnóstico de válvula de uretra anterior pela avaliação pós-natal. Os pacientes foram submetidos a tratamento cirúrgico paliativo, com vesicostomia temporária e, posteriormente, definitivo, pela fulguração endoscópica das válvulas. Ambos evoluíram com função renal normal. Comentários: a válvula da uretra anterior é anomalia rara que deve ser considerada em meninos com quadro radiológico pré-natal sugestivo de obstrução infravesical, secundariamente à hipótese mais comum de válvula da uretra posterior. Ressaltamos a utilização da vesicostomia como derivação urinária temporária nestes casos, prevenindo potenciais complicações pela manipulação da uretra do recém-nascido.Objective: to discuss clinical signs, diagnostic tools and therapeutics of anterior urethral valves, an obstructive anomaly of the urinary system in males. Description: signs of urinary tract obstruction were identified on pre-natal ultrasound in two male fetuses and the diagnosis of anterior urethral valves was made through post-natal evaluation. As an initial treatment, vesicostomy was performed in both patients. Later, the valves were fulgurated using an endoscopic procedure. During the follow-up period both patients presented normal renal function. Comments: anterior urethral valves are a rare form of urethral anomaly that must be ruled out in boys with pre-natal ultrasound indicating infravesical obstruction. Vesicostomy used as an initial treatment rather than transurethral fulguration may prevent potential complications that can occur due to the small size of the neonatal urethra.

  1. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  2. Conjunctival Microbiome Changes Associated With Soft Contact Lens and Orthokeratology Lens Wearing.

    Science.gov (United States)

    Zhang, Haikun; Zhao, Fuxin; Hutchinson, Diane S; Sun, Wenfeng; Ajami, Nadim J; Lai, Shujuan; Wong, Matthew C; Petrosino, Joseph F; Fang, Jianhuo; Jiang, Jun; Chen, Wei; Reinach, Peter S; Qu, Jia; Zeng, Changqing; Zhang, Dake; Zhou, Xiangtian

    2017-01-01

    Usage of different types of contact lenses is associated with increased risk of sight-threatening complications. Changes in the ocular microbiome caused by contact lens wear are suggested to affect infection development in those individuals. To address this question, this study compares conjunctival microbial communities in contact lens wearers with those in noncontact lens wearers. Paired-end sequencing of the V3 region of the 16S rRNA gene was used to characterize the bacterial communities on the conjunctival surfaces of contact lens wearers and nonwearers. No differences in microbial diversity were detected between contact lens wearers and nonwearers. Nevertheless, some slight microbe variability was evident between these two different groups. Bacillus, Tatumella and Lactobacillus abundance was less in orthokeratology lens (OKL) wearers than in nonwearers. In soft contact lenses (SCL) wearers, Delftia abundance decreased whereas Elizabethkingia levels increased. The difference in the SCL and nonwearer group was smaller than that in the OKL group. Variations in the conjunctival taxonomic composition between SCL wearers were larger than those in other groups. Sex differences in the conjunctival microbiota makeup were only evident among nonwearers. Even though there were slight percentage changes between contact lens wearers and nonwearers in some microbes, there were no differences in their diversity. On the other hand, contact lens usage might cause relative abundance of some taxa to change. Our results will help assess whether or not conjunctival microbiome changes caused by contact lens wear affect infection risk.

  3. Variable-focus cylindrical liquid lens array

    Science.gov (United States)

    Zhao, Wu-xiang; Liang, Dong; Zhang, Jie; Liu, Chao; Zang, Shang-fei; Wang, Qiong-hua

    2013-06-01

    A variable-focus cylindrical liquid lens array based on two transparent liquids of different refractive index is demonstrated. An elastic membrane divides a transparent reservoir into two chambers. The two chambers are filled with liquid 1 and liquid 2, respectively, which are of different refractive index. The micro-clapboards help liquid 1, liquid 2 and the elastic membrane form a cylindrical lens array. Driving these two liquids to flow can change the shape of the elastic membrane as well as the focal length. In this design, the gravity effect of liquid can be overcome. A demo lens array of positive optical power is developed and tested. Moreover, a potential application of the proposed lens array for autostereoscopic 3D displays is emphasized.

  4. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  5. Ensuring Safe Use of Contact Lens Solution

    Science.gov (United States)

    ... evaluating contact lens solutions and the development of Acanthamoeba keratitis, a rare but serious eye infection that's ... contact lenses to water has been associated with Acanthamoeba keratitis, a corneal infection that is resistant to ...

  6. Role of Aquaporin 0 in lens biomechanics.

    Science.gov (United States)

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  7. Application of Fourier Domain OCT Imaging Technology to the Anterior Segment of the Human Eye

    Science.gov (United States)

    Wojtkowski, Maciej; Marcos, Susana; Ortiz, Sergio; Grulkowski, Ireneusz

    The anterior segment is the front part of the human eye, which forms the optical system and hence directly impacts vision. Traumatic or pathological changes in the anterior segment may lead to vision loss and, in some cases, even blindness. Since the eighteenth century, optical instrumentation for measuring and imaging the anterior segment of the human eye has been developing along with modern ophthalmology. The application of OCT to the anterior segment imaging is particularly of interest, since this could potentially provide substantial complementary information regarding the large-scale architecture of the cornea and the crystalline lens, or on small portions of tissue imaged with high spatial resolutions comparable to regular microscopy. Especially an introduction of Fourier domain detection in OCT has opened new frontiers in OCT ophthalmic applications. The resultant substantial speed improvement enables rapid image acquisition, helping to reduce artifacts due to patient motion. Thus, it is currently possible to perform high-speed, in vivo, three-dimensional volumetric imaging over large scales within a reasonable time limit and without reducing system sensitivity. This chapter describes the state-of the art OCT technology dedicated to anterior segment imaging and indicates all important parameters which are required for optimization of the performance of OCT instrument.

  8. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  9. Veselago lens by photonic hyper-crystals

    CERN Document Server

    Huang, Zun

    2014-01-01

    An imaging system functioning as a Veselago lens has been proposed based on the novel concept of photonic "hyper-crystal" -- an artificial optical medium synthesizing the properties of hyperbolic materials and photonic crystals. This Veselago lens shows a nearly constant negative refractive index and substantially reduced image aberrations. It can find potential applications in photolithography and hot-spots detection of silicon-based integrated circuits.

  10. Lens Design Using Group Indices of Refraction

    Science.gov (United States)

    Vaughan, A. H.

    1995-01-01

    An approach to lens design is described in which the ratio of the group velocity to the speed of light (the group index) in glass is used, in conjunction with the more familiar phase index of refraction, to control certain chromatic properties of a system of thin lenses in contact. The first-order design of thin-lens systems is illustrated by examples incorporating the methods described.

  11. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  12. A Spectrometer Based on Diffractive Lens

    Institute of Scientific and Technical Information of China (English)

    WANG Daoyi; YAN Yingbai; JIN Guofan; WU Minxian

    2001-01-01

    A novel spectrometer is designed based on diffractive lens. It is essentially a flat field spectrometer. All the focal points are along the optical axis. Besides, all the asymmetrical aberrations vanish in our mounting. Thus low aberration can be obtained. In this article a diffractive lens is modeled as a special grating and analyzed by using a grating-based method. And a stigmatic point is introduced to reduce the aberrations.

  13. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  14. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  15. Evolution and the Calcite Eye Lens

    CERN Document Server

    Williams, Vernon L

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  16. Long-term outcomes among older patients following nonmyeloablative conditioning and allogeneic hematopoietic cell transplantation for advanced hematologic malignancies

    DEFF Research Database (Denmark)

    Sorror, Mohamed L; Sandmaier, Brenda M; Storer, Barry E

    2011-01-01

    A minimally toxic nonmyeloablative regimen was developed for allogeneic hematopoietic cell transplantation (HCT) to treat patients with advanced hematologic malignancies who are older or have comorbid conditions....

  17. Accommodation-Amplitudes following an Accommodative Lens Refilling Procedure — an in vivo Update

    Science.gov (United States)

    Nishi, Okihiro; Nishi, Yutaro; Chang, S.; Nishi, Kayo

    2014-01-01

    Purpose To investigate whether a newly developed lens refilling procedure can provide some accommodation in monkey eyes and to evaluate the difference in accommodation with different degrees of capsular bag refilling. Setting Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Design Experimental monkey study. Methods Following a central 3–4 mm continuous curvilinear capsulorhexis, phacoemulsification was performed in the usual manner. A novel accommodative membrane intraocular lens for sealing capsular opening was implanted into the capsular bag. Silicone polymers were injected beneath the intraocular lens into the capsular bag through the delivery hole. In three study groups, each with six monkey eyes, the lens capsule was refilled with 0.08 ml corresponding to 65% bag volume, 0.1 ml corresponding to 80% bag volume, and 0.125 ml of silicone polymers corresponding to 100% bag volume, respectively. To calculate the accommodation-amplitudes achieved, automated refractometry was performed before and 1 hour after the topical 4% pilocarpine application before and four weeks after surgery. Results The refilling technique was successful in all monkeys without polymer leakage. Accommodation-amplitudes attained were 2.56 ± 0.74 dioptries (D), 2.42 ± 1.00D, and 2.71 ± 0.63D, respectively, 4 weeks after surgery in the three study groups. Conclusions Using the technique, some accommodation could be obtained in the young monkey eyes. Leakage of the injectable silicone polymer and anterior capsular opacification at least in the visual axis could be avoided. The results suggest that this lens refilling procedure warrants further studies for a possible clinical application. PMID:24461501

  18. A correlation of thin lens approximation to thick lens design by using context based method in optics education

    Science.gov (United States)

    Farsakoglu, O. F.; Inal Atik, Ipek; Kocabas, Hikmet

    2014-07-01

    The effect of Coddington factors on aberration functions has been analysed using thin lens approximation with optical glass parameters. The dependence of spherical aberration on Coddington shape factor for the various optical glasses in real lens design was discussed using exact ray tracing for the optics education and training purposes. Thin lens approximation and thick lens design are generally taught with only lecturing method. But, thick lens design is closely related to the real life. Hence, it is more appropriate to teach thin lens approximation and thick lens design with real-life context based approach. Context based teaching can be effective in solving problems in which the subject is very difficult and irrelevant. It also provides extensive evidence for optics education that students are generally unable to correctly apply the concepts of lens design to optical instruments currently used. Therefore, the outline of real-life context based thick lens design lessons were proposed and explained in detail considering thin lens approximation.

  19. Effect of lens status on intraocular pressure in siliconized eyes

    Directory of Open Access Journals (Sweden)

    Mohalhal AA ,El Shazly MI ,Ghalwash DA

    2012-02-01

    Full Text Available Ahmed A Mohalhal, Malak I El Shazly, Dalia A GhalwashKasr El Aini Hospital, Cairo University, Cairo, EgyptPurpose: To evaluate the effect of lens status on intraocular pressure (IOP in siliconized eyes and also on the emulsification of silicone oil.Patients and methods: A total of 31 eyes of 31 patients with retinal detachment were operated on with pars plana vitrectomy and silicone oil injection: 16 phakic (Group A and 15 pseudophakic (Group B. During the 6-month follow-up period, IOP was measured: 1 day postoperative, then at 1 week, 1 month, 2 months, 3 months, and 6 months postoperative. At the end of the follow-up period, gonioscopy was carried out to check emulsified silicone at the anterior chamber angle and also the presence of emulsified silicone on the back of the cornea when the patient was lying down.Results: There was no significant difference between both groups until the first week (P value = 0.15. Starting from the first month, the difference was statistically significant, with mean IOPs in Groups A and B of 14.9 mmHg and 18.2 mmHg, respectively, up to the sixth month (P value = 0.002, with a mean IOP in Groups A and B of 14.4 mmHg and 19.4 mmHg, respectively. Emulsified silicone was clinically stated in twelve cases (80% in Group B and in three cases (19% in Group A.Conclusion: There is a higher incidence of increased IOP and emulsification of silicone oil in pseudophakic eyes than in phakic eyes.Keywords: vitrectomy, siliconized eyes, emulsification, lens status

  20. Photon nanojet lens: design, fabrication and characterization

    Science.gov (United States)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin; Chen, Yifang

    2016-04-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect.

  1. Lens Biology is a Dimension of Neurobiology.

    Science.gov (United States)

    Frederikse, Peter; Kasinathan, Chinnaswamy

    2017-02-04

    There is a second cell type in your body that expresses scores of the most intensively studied genes in neuroscience and exclusively shares critical interdependent modes of molecular regulation that include a network first described as responsible for the basic bifurcation of neuronal from non-neuronal gene expression in vertebrates. Neurons and lens cells are among the most ancient animal cell types, yet neurons have an exclusive status also attributed to roles underlying sensation, movement, and cognition. However, this status is challenged by cells in the lens of the eye. The extent and detail of internally consistent parallels with neuron biology now catalogued in their second native cell type in the lens provide a detailed model of interdependent neuron gene expression in lens development and non-neuronal role in vision. These comprehensive parallels identify the lens as a dimension of neurobiology and a fundamental new perspective on neurodevelopment and its disorders. Finally, this understanding identifies that hallmark neuronal gene expression and key modes of associated molecular regulation evolved in tandem in the lens.

  2. Conservation through the economics lens.

    Science.gov (United States)

    Farley, Joshua

    2010-01-01

    Although conservation is an inherently transdisciplinary issue, there is much to be gained from examining the problem through an economics lens. Three benefits of such an approach are laid out in this paper. First, many of the drivers of environmental degradation are economic in origin, and the better we understand them, the better we can conserve ecosystems by reducing degradation. Second, economics offers us a when-to-stop rule, which is equivalent to a when-to-conserve rule. All economic production is based on the transformation of raw materials provided by nature. As the economic system grows in physical size, it necessarily displaces and degrades ecosystems. The marginal benefits of economic growth are diminishing, and the marginal costs of ecological degradation are increasing. Conceptually, we should stop economic growth and focus on conservation when the two are equal. Third, economics can help us understand how to efficiently and justly allocate resources toward conservation, and this paper lays out some basic principles for doing so. Unfortunately, the field of economics is dominated by neoclassical economics, which builds an analytical framework based on questionable assumptions and takes an excessively disciplinary and formalistic approach. Conservation is a complex problem, and analysis from individual disciplinary lenses can make important contributions to conservation only when the resulting insights are synthesized into a coherent vision of the whole. Fortunately, there are a number of emerging transdisciplines, such as ecological economics and environmental management, that are dedicated to this task.

  3. Reconstruction of beagle hemi-mandibular defects with allogenic mandibular scaffolds and autologous mesenchymal stem cells.

    Directory of Open Access Journals (Sweden)

    ChangKui Liu

    Full Text Available Massive bone allografts are frequently used in orthopedic reconstructive surgery, but carry a high failure rate of approximately 25%. We tested whether treatment of graft with mesenchymal stem cells (MSCs can increase the integration of massive allografts (hemi-mandible in a large animal model.Thirty beagle dogs received surgical left-sided hemi-mandibular defects, and then divided into two equal groups. Bony defects of the control group were reconstructed using allografts only. Those of the experimental group were reconstructed using allogenic mandibular scaffold-loaded autologous MSCs. Beagles from each group were killed at 4 (n = 4, 12 (n = 4, 24 (n = 4 or 48 weeks (n = 3 postoperatively. CT and micro-CT scans, histological analyses and the bone mineral density (BMD of transplants were used to evaluate defect reconstruction outcomes.Gross and CT examinations showed that the autologous bone grafts had healed in both groups. At 48 weeks, the allogenic mandibular scaffolds of the experimental group had been completely replaced by new bone, which has a smaller surface area to that of the original allogenic scaffold, whereas the scaffold in control dogs remained the same size as the original allogenic scaffold throughout. At 12 weeks, the BMD of the experimental group was significantly higher than the control group (p<0.05, and all micro-architectural parameters were significantly different between groups (p<0.05. Histological analyses showed almost all transplanted allogeneic bone was replaced by new bone, principally fibrous ossification, in the experimental group, which differed from the control group where little new bone formed.Our study demonstrated the feasibility of MSC-loaded allogenic mandibular scaffolds for the reconstruction of hemi-mandibular defects. Further studies are needed to test whether these results can be surpassed by the use of allogenic mandibular scaffolds loaded with a combination of MSCs and osteoinductive growth

  4. Epidermoid cyst in Anterior, Middle

    Directory of Open Access Journals (Sweden)

    Kankane Vivek Kumar

    2016-09-01

    Full Text Available Epidermoid cysts are benign slow growing more often extra-axial tumors that insinuate between brain structures, we present the clinical, imaging, and pathological findings in 35 years old female patients with atypical epidermoid cysts which was situated anterior, middle & posterior cranial fossa. NCCT head revealed hypodense lesion over right temporal and perisylvian region with extension in prepontine cistern with mass effect & midline shift and MRI findings revealed a non-enhancing heterogeneous signal intensity cystic lesion in right frontal & temporal region extending into prepontine cistern with restricted diffusion. Patient was detoriated in night of same day of admission, emergency Fronto-temporal craniotomy with anterior peterousectomy and subtotal resection was done. The histological examination confirms the epidermoid cyst. The timing of ectodermal tissue sequestration during fetal development may account for the occurrence of atypical epidermoid cysts.

  5. Pathologic comparison of asymmetric or sulcus fixation of 3-piece intraocular lenses with square versus round anterior optic edges.

    Science.gov (United States)

    Ollerton, Andrew; Werner, Liliana; Strenk, Susan; Strenk, Lawrence; Leishman, Lisa; Bodnar, Zachary; Kirk, Kevin R; Michelson, Jennifer; Mamalis, Nick

    2013-08-01

    To evaluate the pathologic findings of 3-piece intraocular lenses (IOLs) with asymmetric or sulcus fixation in pseudophakic cadaver eyes, comparing IOLs with square or round edges on the anterior optic surface. Comparative case series with pathology. A total of 661 pseudophakic cadaver eyes, obtained from eye banks within the United States, implanted with different IOLs. Anterior segment scanning of whole eyes with a high-frequency ultrasound system or high-resolution anterior segment magnetic resonance imaging followed by gross examination. Selected eyes were processed for complete histopathologic analysis. Findings from imaging, gross, and histopathologic evaluation that could be related to out-of-the-bag fixation of the lenses. Of 661 pseudophakic cadaver eyes obtained, 13 had 3-piece hydrophobic acrylic IOLs with anterior and posterior square optic edges, and 14 had 3-piece lenses with anterior round edges (13 silicone lenses and 1 hydrophobic acrylic lens) without symmetric in-the-bag fixation. These 27 selected eyes were processed for complete histopathologic analysis. Gross findings in both groups were composed of IOL decentration and tilt, pigmentary dispersion within the anterior segment and on the IOL surface, and iris transillumination defects. Histopathology of the 14 eyes with 3-piece IOLs with round anterior optic edges showed mild focal disruption of the iris pigmented layer and loop protrusion/erosion in the ciliary sulcus. Additional changes observed in the 13 eyes with square anterior optic edge IOLs included iris changes, such as vacuolization, disruption and loss of the pigmented epithelial layers, iris thinning and atrophy, synechiae, and pigmentary dispersion within the trabecular meshwork. One eye also exhibited initial signs of optic nerve disc cupping. In this series, pathologic findings were more severe in eyes implanted with 3-piece IOLs with square anterior optic edges, suggesting that IOLs with round anterior edges are more suitable for

  6. 38 CFR 3.379 - Anterior poliomyelitis.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it...

  7. Fenestration of the anterior cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Ito, J.; Washiyama, K.; Hong, K.C.; Ibuchi, Y.

    1981-08-01

    Three cases of angiographically demonstrated fenestration of the anterior cerebral artery are reported. Fenestration occurred at the medial half of the horizontal segment of the anterior cerebral artery in all cases. Its embryology and clinical significance are briefly discussed, and the anatomical and radiological literature on fenestration of the anterior cerebral artery is reviewed.

  8. Dyslipidemia after allogeneic hematopoietic stem cell transplantation: evaluation and management.

    Science.gov (United States)

    Griffith, Michelle L; Savani, Bipin N; Boord, Jeffrey B

    2010-08-26

    Currently, approximately 15,000 to 20,000 patients undergo allogeneic hematopoietic stem cell transplantation (HSCT) annually throughout the world, with the number of long-term survivors increasing rapidly. In long-term follow-up after transplantation, the focus of care moves beyond cure of the original disease to the identification and treatment of late effects after HSCT. One of the more serious complications is therapy-related cardiovascular disease. Long-term survivors after HSCT probably have an increased risk of premature cardiovascular events. Cardiovascular complications related to dyslipidemia and other risk factors account for a significant proportion of late nonrelapse morbidity and mortality. This review addresses the risk and causes of dyslipidemia and impact on cardiovascular complications after HSCT. Immunosuppressive therapy, chronic graft-versus-host disease, and other long-term complications influence the management of dyslipidemia. There are currently no established guidelines for evaluation and management of dyslipidemia in HSCT patients; in this review, we have summarized our suggested approach in the HSCT population.

  9. Alternative donor allogeneic hematopoietic cell transplantation for hemoglobinopathies.

    Science.gov (United States)

    Alfraih, Feras; Aljurf, Mahmoud; Fitzhugh, Courtney D; Kassim, Adetola A

    2016-04-01

    Allogeneic hematopoietic stem cell transplantation (HSCT) offers a curative therapy for patients with hemoglobinopathies, mainly severe sickle cell disease (SCD) and thalassemia (TM). However, the applicability of HSCT has been limited mainly by donor availability, with a less than 25%-30% of eligible patients having human leukocyte antigen (HLA)-matched sibling donors. Previous outcomes using alternate donor options have been markedly inferior due to increased regimen-related toxicity, transplant-related mortality, graft failure, and graft-versus-host disease (GVHD). Advances in transplant technology, including high-resolution HLA typing, improved GVHD prophylactic approaches with tolerance induction, and better supportive care over the last decade, are addressing these historical challenges, resulting in increasing donor options. Herein, we review alternate donor HSCT approaches for severe SCD and TM using unrelated donors, umbilical cord blood units, or related haploidentical donors. Though this is an emerging field, early results are promising and in selected patients, this may be the preferred option to mitigate against the age-related morbidity and early mortality associated with these disorders.

  10. T cell reconstitution in allogeneic haematopoietic stem cell transplantation

    DEFF Research Database (Denmark)

    Kielsen, K; Jordan, K K; Uhlving, H H

    2015-01-01

    Infections and acute graft-versus-host disease (aGVHD) are major causes of treatment-related mortality and morbidity following allogeneic haematopoietic stem cell transplantation (HSCT). Both complications depend on reconstitution of the T-lymphocyte population based on donor T cells. Although...... it is well established that Interleukin-7 (IL-7) is a cytokine essential for de novo T cell development in the thymus and homoeostatic peripheral expansion of T cells, associations between circulating levels of IL-7 and T cell reconstitution following HSCT have not been investigated previously. We...... in patients treated with anti-thymocyte globulin (ATG) compared with those not treated with ATG (P = 0.0079). IL-7 levels at day +7 were negatively associated with T cell counts at day +30 to +60 (at day +60: CD3(+) : β = -10.6 × 10(6) cells/l, P = 0.0030; CD8(+) : β = -8.4 × 10(6) cells/l, P = 0.061; CD4...

  11. Allogenic banking of dental pulp stem cells for innovative therapeutics.

    Science.gov (United States)

    Collart-Dutilleul, Pierre-Yves; Chaubron, Franck; De Vos, John; Cuisinier, Frédéric J

    2015-08-26

    Medical research in regenerative medicine and cell-based therapy has brought encouraging perspectives for the use of stem cells in clinical trials. Multiple types of stem cells, from progenitors to pluripotent stem cells, have been investigated. Among these, dental pulp stem cells (DPSCs) are mesenchymal multipotent cells coming from the dental pulp, which is the soft tissue within teeth. They represent an interesting adult stem cell source because they are recovered in large amount in dental pulps with non-invasive techniques compared to other adult stem cell sources. DPSCs can be obtained from discarded teeth, especially wisdom teeth extracted for orthodontic reasons. To shift from promising preclinical results to therapeutic applications to human, DPSCs must be prepared in clinical grade lots and transformed into advanced therapy medicinal products (ATMP). As the production of patient-specific stem cells is costly and time-consuming, allogenic biobanking of clinical grade human leukocyte antigen (HLA)-typed DPSC lines provides efficient innovative therapeutic products. DPSC biobanks represent industrial and therapeutic innovations by using discarded biological tissues (dental pulps) as a source of mesenchymal stem cells to produce and store, in good manufacturing practice (GMP) conditions, DPSC therapeutic batches. In this review, we discuss about the challenges to transfer biological samples from a donor to HLA-typed DPSC therapeutic lots, following regulations, GMP guidelines and ethical principles. We also present some clinical applications, for which there is no efficient therapeutics so far, but that DPSCs-based ATMP could potentially treat.

  12. Autologous and allogeneic hematopoietic stem cell transplantation in follicular lymphoma.

    Science.gov (United States)

    Bhatt, V R; Armitage, J O

    2016-01-01

    High-dose chemotherapy and autologous stem cell transplantation (ASCT) improve survival in follicular lymphoma; however, relapse remains the most common cause of death. The lower risk of relapse with allogeneic SCT (alloSCT) is offset by a high transplant-related mortality (TRM). English articles indexed in the MEDLINE database were reviewed to discuss the role of graft purging, rituximab maintenance after ASCT, reduced-intensity conditioning (RIC) alloSCT, T-cell depletion, donor lymphocyte infusion (DLI) and alternate donor sources. Optimal salvage consolidation strategy may utilize ASCT following non-total body irradiation-based conditioning regimen in second remission. Rituximab maintenance after ASCT may improve molecular remission but is not yet shown to improve overall survival. RIC alloSCT permits its use in older and less-fit patients. Studies with T-cell depleted graft failed to reduce TRM despite a decline in graft-versus-host disease; however, these studies did demonstrate a therapeutic role of DLI in post-transplant relapses. In recent years, haploidentical and umbilical cord blood donors have emerged as alternative donor sources, with outcomes comparable to matched unrelated donor SCT. In the future, incorporation of novel therapeutic agents, improved risk-adapted treatment strategies, and advancement of transplant techniques may provide a better chance of survival.

  13. Allogeneic anorectal transplantation in rats: technical considerations and preliminary results

    Science.gov (United States)

    Galvão, Flavio H. F.; Waisberg, Daniel R.; Seid, Victor E.; Costa, Anderson C. L.; Chaib, Eleazar; Baptista, Rachel Rossini; Capelozzi, Vera Luiza; Lanchotte, Cinthia; Cruz, Ruy J.; Araki, Jun; D’Albuquerque, Luiz Carneiro

    2016-01-01

    Fecal incontinence is a challenging condition with numerous available treatment modalities. Success rates vary across these modalities, and permanent colostomy is often indicated when they fail. For these cases, a novel potential therapeutic strategy is anorectal transplantation (ATx). We performed four isogeneic (Lewis-to-Lewis) and seven allogeneic (Wistar-to-Lewis) ATx procedures. The anorectum was retrieved with a vascular pedicle containing the aorta in continuity with the inferior mesenteric artery and portal vein in continuity with the inferior mesenteric vein. In the recipient, the native anorectal segment was removed and the graft was transplanted by end-to-side aorta-aorta and porto-cava anastomoses and end-to-end colorectal anastomosis. Recipients were sacrificed at the experimental endpoint on postoperative day 30. Surviving animals resumed normal body weight gain and clinical performance within 5 days of surgery. Isografts and 42.9% of allografts achieved normal clinical evolution up to the experimental endpoint. In 57.1% of allografts, signs of immunological rejection (abdominal distention, diarrhea, and anal mucosa inflammation) were observed three weeks after transplantation. Histology revealed moderate to severe rejection in allografts and no signs of rejection in isografts. We describe a feasible model of ATx in rats, which may allow further physiological and immunologic studies. PMID:27488366

  14. CYTOMEGALOVIRUS INTERSTITIAL PNEUMONITIS FOLLOWING ALLOGENEIC PERIPHERAL BLOOD STEM CELL TRANSPLANTATION

    Institute of Scientific and Technical Information of China (English)

    XU Xiao-hua; HUANG Lian-sheng; ZHANG Xiao-hong; ZHU Kang-er; XU Yang; WU Dong; ZHAO Xiao-ying

    2005-01-01

    Objective: To explore the risk factors and prophylaxis and treatment of cytomegalovirus interstitial pneumonitis(CMV-IP) after allogeneic peripheral blood stem cell transplantation (allo-PBSCT). Methods: 43 patients who received allo-PBSCT were allocated to either a Gancyclovir(GCV)-prophylaxis group (n=19) or a non-GCV prophylaxis group (n=24).A comparison was made of the incidence of CMV-IP in patients given or not given prophylactic gancyclovir. Results: 9patients in non-GCV prophylaxis group developed late CMV-IP (P<0.05). Graft-versus-host-disease (GVHD) may be associated with a high risk of CMV-IP. 5 cases of CMV-IP were successfully treated with GCV, but 3 cases died of CMV-IP.The most common adverse event of GCV was neutropenia, but was reversible. Conclusion: CMV infection was a major cause of interstitial pneumonitis after allo-PBSCT, which correlated strongly with the severity of GVHD. Gancyclovir was shown to be effective in both prophylaxis and treatment of CMV-IP.

  15. Hypomethylating agents after allogeneic blood stem cell transplantation

    Science.gov (United States)

    Rautenberg, Christina; Haas, Rainer; Kobbe, Guido

    2016-01-01

    Allogeneic blood stem cell transplantation (allo-SCT) is a potentially curative treatment for patients with myeloid malignancies such as acute myeloid leukemia (AML) and myelodysplastic syndromes (MDS), but relapse remains the major cause of treatment failure. So far, therapeutic options for patients with AML or MDS who relapse after allo-SCT generally consisted of palliative care, low-dose or intensive chemotherapy as well as cellular therapies such as donor lymphocyte infusions (DLI) and second transplantation in selected cases. Nevertheless, the prognosis of patients with myeloid malignancies relapsing after allo-SCT remains dismal therefore asking for novel treatment strategies. Considering their well-balanced profile of good efficacy and moderate toxicity in the non-transplant setting, the hypomethylating agents (HMA) azacitidine (Aza) and decitabine (DAC) have also been tested either alone or in combination with DLI in the post-transplant period. This review summarizes the current knowledge about the use of these two HMA as pre-emptive, salvage or consolidation therapy mostly retrieved from retrospective studies but also from a few prospective trials. Within this review, we also comment on some practical issues such as optimal dose and schedule, the choice of HMA candidates and the role of additional cellular interventions. Finally, we also give an overview on the assumed mode of actions, ongoing research, clinical studies and potential combination partners aiming to improve this treatment approach. PMID:28066786

  16. Pneumatosis intestinalis in children after allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yeager, A.M.; Kanof, M.E.; Lake, A.M.; Kramer, S.S.; Jones, B.; Saral, R.; Santos, G.W.

    1987-01-01

    Four children, ages 3 to 8 years, developed pneumatosis intestinalis (PI) after allogeneic bone marrow transplantation (BMT) for acute leukemia or severe aplastic anemia. PI was detected at a median of 48 days (range, 10-63 days) after BMT and was associated with abdominal symptoms and clinical signs. All patients had severe systemic and/or highgrade cutaneous acute graft-versus-host disease (AGVHD) at some time after BMT and were receiving corticosteroids at the time of development of PI; however, PI was associated with concomitant severe AGVHD in only one patient. One patient with PI had Hafnia alvei bacteremia and another patient had gastroenteritis due to rotavirus and adenovirus. All patients were treated with supportive care and systemic broad-spectrum antibiotics, and PI resolved 2-16 days after onset. Two patients died with BMT-associated complications unrelated to PI. Multiple factors contribute to the development of PI after BMT, and the prognosis for recovery from PI is good with medical management alone. Overall survival in these patients is dependent on the frequency and severity of other conditions, such as AGVHD and opportunistic infections, after BMT.

  17. Allogenic banking of dental pulp stem cells for innovative therapeutics

    Institute of Scientific and Technical Information of China (English)

    Pierre-Yves; Collart-Dutilleul; Franck; Chaubron; John; De; Vos; Frédéric; J; Cuisinier

    2015-01-01

    Medical research in regenerative medicine and cellbased therapy has brought encouraging perspectives for the use of stem cells in clinical trials. Multiple types of stem cells, from progenitors to pluripotent stem cells, have been investigated. Among these, dental pulp stem cells(DPSCs) are mesenchymal multipotent cells coming from the dental pulp, which is the soft tissue within teeth. They represent an interesting adult stem cell source because they are recovered in large amount in dental pulps with non-invasive techniques compared to other adult stem cell sources. DPSCs can be obtained from discarded teeth, especially wisdom teeth extracted for orthodontic reasons. To shift from promising preclinical results to therapeutic applications to human, DPSCs must be prepared in clinical grade lots and transformed into advanced therapy medicinal products(ATMP). As the production of patient-specific stem cells is costly and time-consuming, allogenic biobanking of clinical grade human leukocyte antigen(HLA)-typed DPSC lines provides efficient innovative therapeutic products. DPSC biobanks represent industrial and therapeutic innovations by using discarded biological tissues(dental pulps) as a source of mesenchymal stem cells to produce and store, in good manufacturing practice(GMP) conditions, DPSC therapeutic batches. In this review, we discuss about the challenges to transfer biological samples from a donor to HLA-typed DPSC therapeutic lots, following regulations, GMP guidelines and ethical principles. We also present some clinical applications, for which there is no efficient therapeutics so far, but that DPSCs-based ATMP could potentially treat.

  18. [Femtosecond laser-assisted lens surgery depending on interface design and laser pulse energy: results of the first 200 cases].

    Science.gov (United States)

    Mayer, W J; Klaproth, O K; Ostovic, M; Hengerer, F H; Kohnen, T

    2014-12-01

    This study was designed to evaluate the effectiveness and safety of femtosecond laser-assisted lens surgery depending on interface design and laser pulse energy settings. In this non-randomized, consecutive case series200 eyes underwent femtosecond laser-assisted (LenSx, Alcon) lens surgery between November 2012 and June 2013. Group 1 consisted of 85 eyes with 60 cataracts and 25 refractive lens exchanges (RLE) which were treated with a curved direct contact interface, and group 2 consisting of 115 eyes with 72 cataracts and 43 RLEs treated with a modified interface using an additional soft contact lens (SoftFit™, Alcon) between the corneal surface and the interface. The degree of opacity of the lens in cataract eyes was measured with a Scheimpflug camera. Afterwards, phacoemulsification was performed with intraocular lens (IOL) implantation in all eyes. Primary endpoints were the effective phacoemulsification time (EPT), the average laser treatment time and the occurrence of intraoperative complications. The mean EPT in group 1 was 1.62 ± 1.12 s (cataract 1.94 ± 1.31 s, RLE 1.29 ± 1.01 s) and in group 2 the mean EPT was 1.66 ± 0.92 s (cataract 1.98 ± 1.28 s, RLE 1.33 ± 1.22 s, p = 0.32 between groups). The laser treatment lasted on average 48.90 ± 2.45 s (group 1) and 49.70 ± 2.87 s (group 2) with an average lens fragmentation thickness of 3401.48 ± 401.12 µm (all groups). In four cases of group 1, a second applanation of the interface was necessary. Furthermore, one anterior capsule tear, 39 cases of intraoperative wrinkling of the corneal surface and 21 cases in which the corneal incision had to be opened manually were documented in group 1. In group 2 no second applanation of the interface, no anterior capsule tears and no corneal wrinkling but 9 cases with a manual opening of corneal incisions were documented (p interface and reduced laser pulse energy.

  19. The Sloan Lens ACS Survey. V. The full ACS strong-lens sample

    NARCIS (Netherlands)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Gavazzi, Raphael; Moustakas, Leonidas A.; Wayth, Randall; Schlegel, David J.

    2008-01-01

    We present the definitive data for the full sample of 131 strong gravitational lens candidates observed with the Advanced Camera for Surveys (ACS) aboard the Hubble Space Telescope by the Sloan Lens ACS (SLACS) Survey. All targets were selected for higher redshift emission lines and lower redshift

  20. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was refi

  1. Gravitational binary-lens events with prominent effects of lens orbital motion

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.; Han, C.; Choi, J.-Y. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Udalski, A.; Szymański, M. K.; Kubiak, M.; Soszyński, I.; Pietrzyński, G.; Poleski, R.; Ulaczyk, K.; Pietrukowicz, P.; Kozłowski, S.; Skowron, J.; Wyrzykowski, Ł. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Beaulieu, J.-P. [Institut d' Astrophysique de Paris, UMR 7095 CNRS-Université Pierre and Marie Curie, 98bis Bd Arago, F-75014 Paris (France); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Depoy, D. L. [Department of Physics and Astronomy, Texas A and M University, College Station, TX 77843 (United States); Dong, Subo [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States); Collaboration: OGLE Collaboration; μFUN Collaboration; PLANET Collaboration; RoboNet Collaboration; and others

    2013-12-01

    Gravitational microlensing events produced by lenses composed of binary masses are important because they provide a major channel for determining physical parameters of lenses. In this work, we analyze the light curves of two binary-lens events, OGLE-2006-BLG-277 and OGLE-2012-BLG-0031, for which the light curves exhibit strong deviations from standard models. From modeling considering various second-order effects, we find that the deviations are mostly explained by the effect of the lens orbital motion. We also find that lens parallax effects can mimic orbital effects to some extent. This implies that modeling light curves of binary-lens events not considering orbital effects can result in lens parallaxes that are substantially different from actual values and thus wrong determinations of physical lens parameters. This demonstrates the importance of routine consideration of orbital effects in interpreting light curves of binary-lens events. It is found that the lens of OGLE-2006-BLG-277 is a binary composed of a low-mass star and a brown dwarf companion.

  2. The Sloan Lens ACS Survey. V. The full ACS strong-lens sample

    NARCIS (Netherlands)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Gavazzi, Raphael; Moustakas, Leonidas A.; Wayth, Randall; Schlegel, David J.

    2008-01-01

    We present the definitive data for the full sample of 131 strong gravitational lens candidates observed with the Advanced Camera for Surveys (ACS) aboard the Hubble Space Telescope by the Sloan Lens ACS (SLACS) Survey. All targets were selected for higher redshift emission lines and lower redshift c

  3. DISSECTING THE GRAVITATIONAL LENS B1608+656. I. LENS POTENTIAL RECONSTRUCTION

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Blandford, R. D.; Fassnacht, C. D.; Koopmans, L. V. E.; McKean, J. P.; Treu, T.

    2009-01-01

    Strong gravitational lensing is a powerful technique for probing galaxy mass distributions and for measuring cosmological parameters. Lens systems with extended source-intensity distributions are particularly useful for this purpose since they provide additional constraints on the lens potential ( m

  4. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    Directory of Open Access Journals (Sweden)

    Ladan Espandar

    2011-01-01

    Full Text Available Ladan Espandar1, Shameema Sikder2, Majid Moshirfar31Department of Ophthalmology, Tulane University, New Orleans, LA, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USAAbstract: Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular lens (IOL. The hydrophilic design of the lens is optimized to address dysphotopsia while maintaining biocompatibility, optical clarity, resistance to damage, and resistance to biocontamination. Aspheric lenses decrease postoperative spherical aberration. The addition of the Softec lens provides clinicians with another option for IOL placement; however, randomized comparative studies of this lens to others already on the market remain to be completed.Keywords: hydrophilic acrylic intraocular lens, Softec HD intraocular lens, aspheric intraocular lens, IOL

  5. An improved spinning lens test to determine the stiffness of the human lens

    Science.gov (United States)

    Burd, H.J.; Wilde, G.S.; Judge, S.J.

    2011-01-01

    It is widely accepted that age-related changes in lens stiffness are significant for the development of presbyopia. However, precise details on the relative importance of age-related changes in the stiffness of the lens, in comparison with other potential mechanisms for the development of presbyopia, have not yet been established. One contributing factor to this uncertainty is the paucity and variability of experimental data on lens stiffness. The available published data generally indicate that stiffness varies spatially within the lens and that stiffness parameters tend to increase with age. However, considerable differences exist between these published data sets, both qualitatively and quantitatively. The current paper describes new and improved methods, based on the spinning lens approach pioneered by Fisher, R.F. (1971) ‘The elastic constants of the human lens’, Journal of Physiology, 212, 147–180, to make measurements on the stiffness of the human lens. These new procedures have been developed in an attempt to eliminate, or at least substantially reduce, various systematic errors in Fisher’s original experiment. An improved test rig has been constructed and a new modelling procedure for determining lens stiffness parameters from observations made during the test has been devised. The experiment involves mounting a human lens on a vertical rotor so that the lens spins on its optical axis (typically at 1000 rpm). An automatic imaging system is used to capture the outline of the lens, while it is rotating, at pre-determined angular orientations. These images are used to quantify the deformations developed in the lens as a consequence of the centripetal forces induced by the rotation. Lens stiffness is inferred using axisymmetric finite element inverse analysis in which a nearly-incompressible neo-Hookean constitutive model is used to represent the mechanics of the lens. A numerical optimisation procedure is used to determine the stiffness parameters

  6. Mitochondrial oxygen metabolism in primary human lens epithelial cells: Association with age, diabetes and glaucoma.

    Science.gov (United States)

    Kubota, M; Shui, Y B; Liu, M; Bai, F; Huang, A J; Ma, N; Beebe, D C; Siegfried, C J

    2016-08-01

    The hypoxic environment around the lens is important for maintaining lens transparency. Lens epithelial cells (LECs) play a key role in lens metabolism. We measured oxygen consumption to assess the role of human LECs in maintaining hypoxia around the lens, as well as the impact of systemic and ocular diagnosis on these cells. Baseline cellular respiration was measured in rabbit LECs (NN1003A), canine kidney epithelial cells (MDCK), trabecular meshwork cells (TM-5), and bovine corneal endothelial cells (CCEE) using a XF96 Extracellular Flux Analyzer (Seahorse Bioscience, North Billerica, MA), which measures oxygen consumption rate (OCR) and extracellular acidification rate (ECAR) in vitro. Following informed written consent, lens capsule epithelial cells were obtained from patients during cataract surgery and were divided into small explants in 96-well plates. Capsules were removed when LECs became confluent. OCR was normalized to the number of cells per well using rabbit LECs as a standard. The effect of patient age, sex, race, and presence of diabetes or glaucoma on oxygen consumption was assessed by using the Mann-Whitney U test and multivariate regression analysis. Primary LECs were obtained from 69 patients. The OCR from donors aged 70 and over was lower than that of those under 70 years (2.21±1.037 vs. 2.86±1.383 fmol/min/cell; pOCR than non-diabetic patients (2.02±0.911 vs. 2.79±1.332fmol/min/cell; pOCR than non-glaucoma patients (2.27±1.19 vs. 2.83±1.286 fmol/min/cell; pOCR, independent of other variables. Gender and race had no significant effect on OCR. The lower oxygen consumption rate of human LECs in older donors and patients with diabetes or glaucoma could contribute to cataract development. Diabetes and glaucoma are particularly important factors associated with decreased OCR, independent of age. Ongoing studies are examining pO2 at the anterior surface of the lens in vivo and oxygen consumption in the patient's LECs. Copyright © 2016 Elsevier

  7. Corneal topography and soft contact lens fit.

    Science.gov (United States)

    Young, Graeme; Schnider, Cristina; Hunt, Chris; Efron, Suzanne

    2010-05-01

    To determine which ocular topography variables affect soft contact lens fit. Fifty subjects each wore three pairs of soft lenses in random succession (Vistakon Acuvue 2, Vistakon Acuvue Advance, Ciba Vision Night & Day), and various aspects of lens fit were evaluated. The steeper base curves of each type were worn in one eye and the flatter base curves in the other eye. Corneal topography data were collected using a Medmont E300 corneal topographer (Camberwell, Australia). Corneal curvature, shape factor (SF), and corneal height were measured over a 10 mm chord and also over the maximum measurable diameter. These were measured in the horizontal, vertical, steepest, and flattest meridians. With each lens type, the steeper base curve provided the best fit on the greatest proportion of eyes and the significant differences in various aspects of fit were noted between base curves. For each lens type, there was no significant difference in mean K-reading between those eyes best fit with the steeper base curve and those eyes best fit with the flatter base curve. Two of the lenses showed a positive correlation between centration and horizontal corneal height (maximum), whereas one lens showed a negative correlation between centration and horizontal SF (SF = e). Several lenses showed a positive correlation between post-blink movement and horizontal or vertical corneal SF. The measurement of corneal topography using current Placido disc instrumentation allows a better prediction of soft lens fit than by keratometry, but it is not reliable enough to enable accurate selection of the best fitting base curve. Some correlations are evident between corneal measurements; however, trial fitting remains the method of choice for selection of soft lens base curve.

  8. Capsular bag opacification with a new accommodating intraocular lens.

    Science.gov (United States)

    Floyd, Anne M; Werner, Liliana; Liu, Erica; Stallings, Shannon; Ollerton, Andrew; Leishman, Lisa; Bodnar, Zachary; Morris, Caleb; Mamalis, Nick

    2013-09-01

    To evaluate the biocompatibility and capsular bag opacification of an accommodating intraocular lens (IOL) containing large haptic elements that separate the anterior and posterior capsules. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Bilateral phacoemulsification with IOL implantation was performed in 6 New Zealand rabbits. Each animal received a study (accommodating) IOL and a control (1-piece hydrophobic acrylic) IOL. Eyes were examined at the slitlamp from 1 day through 6 weeks postoperatively. The globes were then enucleated and evaluated grossly. Capsular bag opacification was scored from the posterior aspect (Miyake-Apple view). The eyes were then processed for complete histopathologic evaluation. At 6 weeks, the mean posterior capsule opacification (PCO) clinical score was 0.5 ± 0.3 (SD) in the study group and 3.0 ± 0.9 in the control group (P=.001, 2-tail paired t test). Anterior capsule opacification was practically absent in the study group and mild in the control group. Miyake-Apple posterior view showed a mean central PCO score of 0 ± 0 in the study group and 3.0 ± 1.1 in the control group (P=.001), peripheral PCO score of 0.7 ± 0.4 and 3.5 ± 0.8 (P=.0006), respectively, and Soemmerring ring score of 2.3 ± 0.8 and 7.0 ± 2.8 (P=.01), respectively. Histopathology showed no signs of toxicity in any eye. The study IOL maintained an expanded capsular bag secondary to the large size of the haptic elements, which appears to prevent capsular bag opacification. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  10. Intraocular lens alignment from an en face optical coherence tomography image Purkinje-like method

    Science.gov (United States)

    Sun, Mengchan; de Castro, Alberto; Ortiz, Sergio; Perez-Merino, Pablo; Birkenfeld, Judith; Marcos, Susana

    2014-06-01

    Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance. We present a method to estimate tilt and decentration of IOLs based on optical coherence tomography (OCT) images. En face OCT images show Purkinje-like images that correspond to the specular reflections from the corneal and IOL surfaces. Unlike in standard Purkinje-imaging, the tomographic nature of OCT allows unequivocal association of the reflection with the corresponding surface. The locations of the Purkinje-like images are linear combinations of IOL tilt, IOL decentration, and eye rotation. The weighting coefficients depend on the individual anterior segment geometry, obtained from the same OCT datasets. The methodology was demonstrated on an artificial model eye with set amounts of lens tilt and decentration and five pseudophakic eyes. Measured tilt and decentration in the artificial eye differed by 3.7% and 0.9%, respectively, from nominal values. In patients, average IOL tilt and decentration from Purkinje were 3.30±4.68 deg and 0.16±0.16 mm, respectively, and differed on average by 0.5 deg and 0.09 mm, respectively, from direct measurements on distortion-corrected OCT images. Purkinje-based methodology from anterior segment en face OCT imaging provided, therefore, reliable measurements of IOL tilt and decentration.

  11. Imaging of aphakic intraocular lens with a slit-scanning tomography system

    Science.gov (United States)

    Oliveira, Cristina M.; Almeida, J. B.; Franco, S.

    2011-05-01

    Nowadays, cataract extraction with IOL implantation aims not only to restore the crystalline lens' transparency, but also to improve patients' retinal image quality. The refractive outcome and visual quality in pseudophakic eyes is mainly determined by the combination of corneal and internal optics resulting from the implanted IOLs. The optical function of the IOLs depends on its position in the eye. The IOL distance to the corneal apex determines the optical power needed for optical correction. In this paper it is described the usage of a slit-scanning imaging system to determine IOL positioning. Through the projection of the light from a slit onto the eye, this tomography system allows to acquire multiple sections of the anterior eye segment, at different meridians. The developed system's software corrects geometric and optical distortion of the images and provides 3-dimentional models of the eye's structures from the 2-dimensional sections. With this noninvasive technique, cross-sectional images of an eye with an aphakic IOL were obtained in order to reconstruct its 3- dimensional model of the lens and assess its position in the anterior segment camera.

  12. Imaging characteristics of a volume holographic lens

    Science.gov (United States)

    Yang, Jing; Jiang, Zhu-qing; Xu, Zhi-qiang; Liu, Shao-jie; Sun, Ya-jun; Tao, Shi-quan

    2009-07-01

    A volume holographic grating lens can reconstruct the three-dimensional information by conducting multiple optical slicing of an object based on Bragg selectivity of the volume holographic grating. In this paper, we employ the point-spread function of volume holographic imaging system to theoretically analyze its imaging resolution. In the experiments, the volume holographic gratings are made with a spherical reference (SR) and a planar reference (PR), respectively, and used as volume holographic imaging lens in our imaging system. The longitudinal and lateral defocusing characteristics of volume holographic lens with SR and with PR are investigated experimentally by displacing the interested objects from original reference location, respectively. The effects of the parameters of the volume holographic lens on the longitudinal and lateral resolution are also discussed. The experimental results show that increasing the size of the volume holographic lens can improve the depth resolution, and in particular, it has greater influence on SR VHI. The lateral selectivity of SR VHI is more sensitive than that of PR VHI, and the Bragg degenerate diffraction of PR VHI on the y axis is obviously observed.

  13. DAS181 Treatment of Severe Parainfluenza Virus 3 Pneumonia in Allogeneic Hematopoietic Stem Cell Transplant Recipients Requiring Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    B. Dhakal

    2016-01-01

    Full Text Available Parainfluenza virus (PIV may cause life-threatening pneumonia in allogeneic hematopoietic stem cell transplant (HSCT recipients. Currently, there are no proven effective therapies. We report the use of inhaled DAS181, a novel sialidase fusion protein, for treatment of PIV type 3 pneumonia in two allogeneic hematopoietic SCT recipients with respiratory failure.

  14. Eradication of tumour cells by successive injections of allogeneic immune and hyperimmune peritoneal cells in a murine lymphoma system

    NARCIS (Netherlands)

    Dullens, H.F.J.; Woutersen, R.A.; Weger, R.A. de; Otter, W. den

    2006-01-01

    Allogeneic C57BL immune and hyperimmune (vs SL2) peritoneal cells are used for eradication of DBA/2 derived SL2 lymphoma cells injected into the peritoneal cavity of DBA/2 mice. SL2 bearing DBA/2 mice are treated with 3, 5, or 8 successive i.p. injections of 2 × 106 allogeneic C57BL immune or hyper

  15. Allogeneic transplantation of the radial side of the hand in the rhesus monkey : technical, functional and immunological aspects.

    NARCIS (Netherlands)

    S.E.R. Hovius (Steven); H.P.J.D. Stevens (Jeroen)

    1991-01-01

    textabstractAs this is the era of transplantation it is inevitable that the field of allogeneic transplantation for the reconstruction of the upper extremity is explored also. This double-thesis deals with a number of aspects concerning allogeneic transplantation of the radial side of the hand in a

  16. A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens

    Directory of Open Access Journals (Sweden)

    Senthil Sirisha

    2006-01-01

    Full Text Available Purpose: To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL in high myopia. Materials and Methods: A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. Results: An Artisan myopia lens was implanted in 60 eyes of 36 patients with preoperative myopia ranging from -5.0 to -24.0 D. Mean patient age was 22.6 years. Mean spherical equivalent of manifest refraction stabilized by the first postoperative week. At three months follow-up, 54 eyes (90% had a postoperative refraction within ± 1D emmetropia and 45 eyes (75% had uncorrected visual acuity of 20/40 or better. Seven eyes (11.6% had loss of one Snellen line and none had loss of two Snellen lines or more at three months. The mean endothelial cell loss was 3.8% at three months, 5.2% at six months, 5.25% at 12 months and 6.38% at two years, which was not significant. Postoperative complications included anterior chamber reaction in two eyes (3.3%, rise in intraocular pressure in six eyes (10% and dislocation of PIOL in two eyes (3.3%. Conclusion: Implantation of Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome with few complications. Significant endothelial damage was not detected in two years of follow-up.

  17. Safety levels for exposure of cornea and lens to very high-frequency ultrasound.

    Science.gov (United States)

    Silverman, R H; Lizzi, F L; Ursea, B G; Cozzarelli, L; Ketterling, J A; Deng, C X; Folberg, R; Coleman, D J

    2001-09-01

    Very high-frequency (50-MHz) ultrasound is widely used for imaging the anterior segment of the eye. Our aim was to determine whether exposures to ultrasound at and above those used in diagnostic imaging systems might cause bioeffects in ocular tissues. We characterized the output parameters of a polyvinylidene difluoride transducer using a needle hydrophone. We exposed sites on the cornea or lens of rabbits for up to 30 minutes at a 10-kHz pulse repetition frequency. Tissue obtained immediately or 24 hours after exposure was examined by light microscopy. A numeric model was implemented to calculate expected temperature elevations in the cornea and lens under experimental conditions. No tissue changes were observed directly or by slit lamp. Light microscopy showed no abnormalities attributable to ultrasound exposure. Simulations showed that even long-term exposures should produce temperature elevations of less than 1 degree C in both the cornea and lens. With the use of exposure parameters 4 to 5 orders of magnitude greater than encountered in a clinical situation, no tissue changes were observed. This is consistent with the small (0.2 degrees C) temperature rises computed in simulations. The lack of biological effects is attributable to the small dimensions of the focal zone, allowing rapid dissipation of heat, and the low total acoustic power produced by the transducer.

  18. [Visco-hydraulic irrigation of the lens cortex. A safe ECCE method].

    Science.gov (United States)

    Friedburg, D

    1994-12-01

    The safe and effective Hydrojet nucleus expression (Klin Monatsbl Augenheilkd 1993; 202:288-291) should be completed by a safe non traumatic and easy to perform method of cortex removal. OPERATION TECHNIQUE: 8-mm tunnel incision, spiral capsulorhexis, hydrodissection and viscodissection of the nucleus, hydrojet nucleus expression. The lens cortex can be separated from the lens capsule by injection of hydroxypropylmethylcellulose (Metho), the viscoelastic substance acts as a wedge to separate the cortex from the capsule step by step. Finally the cortex is expressed by the injection of Metho. The capsule remains so clean, that often polishing is not necessary. PMMA lenses with an over all diameter of 10 or 11-mm and 7-mm optics were implanted. In 100 consecutive cases complications which occurred intraoperatively or within the following 2 days were listed. The following complications occurred: Hyphaema (2x, the blood disappeared spontaneously within 4-5 days), small cortex flake in the anterior chamber (2x), rhexis rim not intact (1x, nevertheless exact lens centration in the bag). No lesion of the capsule/zonule diaphragm, no fibrin reaction, no corneal edema. The method described is a safe method for ECCE. Capsulorhexis and tunnel incision are required. The method does not need any high technology equipment.

  19. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  20. Change in over-refraction after scleral lens settling on average corneas.

    Science.gov (United States)

    Bray, Chelsea; Britton, Stephanie; Yeung, Debby; Haines, Lacey; Sorbara, Luigina

    2017-07-01

    The purpose of this study was to determine the change in over-refraction, if any, after a scleral lens settled on the eye for 6-8 h. Sixteen patients of varying refractive errors and normal corneal curvatures (measured with Pentacam(™) Oculus) were fitted with trial Mini-Scleral Design (MSD) scleral lenses (15.8 mm diameter) in one eye. The sagittal depths of the scleral lenses were selected by adding 350 μm to the corneal sagittal heights measured at a chord length of 15 mm with the Visante(™) optical coherence tomographer (OCT) anterior segment scans and picking the closest available trial lens in the set. Initial measurements were taken 30 min after lens insertion and included an auto-refraction, subjective refraction, and best sphere refraction over the contact lens. Visual acuities and Visante(™) OCT anterior segment scans were also taken. These measurements were repeated after 6-8 h of lens wear. Over the trial wearing period, the average change in the spherical component of the over-refraction was +0.06 D (S.D. 0.17) (p = 0.16). The average change in cylinder was +0.04 D (S.D. 0.19) (p = 0.33). The average absolute change in axis was 1.06° (S.D. 12.11) (p = 0.74). The average change in best sphere was +0.13 ± 0.30 D (p = 0.12). There was no significant change in visual acuity with the best sphere over-refraction over the 6-8 h wearing period. There was a significant change in central corneal clearance over the wearing period of 83 μm (S.D. 22) (p refraction (sphere, cylinder, and axis) or best sphere or visual acuity. This study has confirmed that there is no link between reduction in central corneal clearance and change in over-refraction for average corneas. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  1. Responses of the Ocular Anterior Segment and Refraction to 0.5% Tropicamide in Chinese School-Aged Children of Myopia, Emmetropia, and Hyperopia

    Directory of Open Access Journals (Sweden)

    Ying Yuan

    2015-01-01

    Full Text Available Purpose. To investigate the changes of anterior segment after cycloplegia and estimate the association of such changes with the changes of refraction in Chinese school-aged children of myopia, emmetropia, and hyperopia. Methods. 309 children were recruited and eligible subjects were assigned to three groups: hyperopia, emmetropia, or myopia. Cycloplegia was achieved with five cycles of 0.5% tropicamide. The Pentacam system was used to measure the parameters of interest before and after cycloplegia. Results. In the myopic group, the lenses were thinner and the lens position was significantly more posterior than that of the emmetropic and hyperopic groups in the cycloplegic status. The correlations between refraction and lens thickness (age adjusted; r=0.26, P<0.01, and lens position (age adjusted; r=-0.31, P<0.01 were found. After cycloplegia, ACD and ACV significantly increased, while ACA significantly decreased. Changes in refraction, ACD, ACV, and ACA were significantly different among the three groups (P<0.05, all. Changes of refraction were correlated with changes of ACD (r=0.41, P<0.01. Conclusions. Myopia presented thinner lenses and smaller changes of anterior segment and refraction after cycloplegia when compared to emmetropia and hyperopia. Changes of anterior chamber depth were correlated with refraction changes. This may contribute to a better understanding of the relationship between anterior segment and myopia.

  2. Allogeneic and autologous mode of stem cell transplantation in regenerative medicine: which way to go?

    Science.gov (United States)

    Mamidi, Murali Krishna; Dutta, Susmita; Bhonde, Ramesh; Das, Anjan Kumar; Pal, Rajarshi

    2014-12-01

    Stem cell transplantation is a generic term covering different techniques. However there is argument over the pros and cons of autologous and allogeneic transplants of mesenchymal stem cells (MSCs) for regenerative therapy. Given that the MSCs have already been proven to be safe in patients, we hypothesize that allogeneic transplantation could be more effective and cost-effective as compared to autologous transplantation specifically in older subjects who are the likely victims of degenerative diseases. This analysis is based on the scientific logic that allogeneic stem cells extracted in large numbers from young and healthy donors could be physiologically, metabolically and genetically more stable. Therefore stem cells from young donors may be expected to exhibit higher vigor in secreting trophic factors leading to activation of host tissue-specific stem cells and also be more efficient in remodeling the micro-environmental niche of damaged tissue.

  3. Allogeneic hematopoietic cell transplantation without fluconazole and fluoroquinolone prophylaxis.

    Science.gov (United States)

    Heidenreich, D; Kreil, S; Nolte, F; Reinwald, M; Hofmann, W-K; Klein, S A

    2016-01-01

    Fluoroquinolone (FQ) and fluconazole prophylaxis is recommended for patients undergoing allogeneic hematopoietic cell transplantation (alloHCT). However, due to an uncertain scientific basis and the increasing emergence of resistant germs, this policy should be questioned. Therefore, FQ and fluconazole prophylaxis was omitted in alloHCT at our center. In this retrospective analysis, all consecutive patients (n = 63) who underwent first alloHCT at our institution from September 2010 to September 2013 were included. Patients neither received FQ nor fluconazole prophylaxis. Day 100 mortality, incidence of febrile neutropenia, bacterial infections, and invasive fungal diseases (IFD) were assessed. Sixteen patients who started conditioning under antimicrobial treatment/prophylaxis due to pre-existing neutropenia (3/16), IFD (12/16), or aortic valve replacement (1/16) were excluded from the analysis. Finally, 47 patients were transplanted without prophylaxis as intended. Day 100 mortality was 9 %. Febrile neutropenia occurred in 62 % (29/47); 17/47 patients (36 %) experienced a blood stream infection (BSI) with detection of Gram-positive bacteria in 14 patients, Gram-negative bacteria in five patients, and candida in one patient, respectively. Coagulase-negative staphylococci were the most frequently isolated Gram-positive bacteria; 12/21 isolated Gram-positive and 3/6 Gram-negative bacteria were FQ resistant. In 21 % (10/47) of the patients, IFD (1x proven, 1x probable, and 8x possible) were diagnosed. To conclude, all three criteria, day 100 mortality, the incidence of IFD, and BSI, are in the range of published data for patients transplanted with FQ and fluconazole prophylaxis. These data demonstrate that alloHCT is feasible without FQ and fluconazole prophylaxis.

  4. Intrasplenic transplantation of allogeneic hepatocytes prolongs survival in anhepatic rats.

    Science.gov (United States)

    Arkadopoulos, N; Lilja, H; Suh, K S; Demetriou, A A; Rozga, J

    1998-11-01

    To examine whether hepatocytes transplanted in the spleen can function as an ectopic liver, we performed hepatocyte transplantation in rats that were rendered anhepatic. Total hepatectomy was performed by using a novel single-stage technique. Following hepatectomy, Group 1 rats (n = 16) were monitored until death to determine survival time without prior intervention. Group 2 anhepatic rats (n = 20) were sacrificed at various times to measure blood hepatocyte growth factor (HGF) and transforming growth factor beta1 (TGF-beta1) levels. Group 3 (n = 16) rats received intrasplenic injection of isolated hepatocytes (2.5 x 10(7) cells/rat) followed by total hepatectomy after 3 days. Group 4 (n = 12) sham-transplanted rats received intrasplenic saline infusion, and after 3 days they were rendered anhepatic. Group 2, 3, and 4 rats were maintained on daily Cyclosporine A (10 mg/kg; intramuscularly). Group 1 anhepatic rats survived for 22.4 +/- 5.2 hours (standard deviation). The anhepatic state was associated with a progressive and statistically significant rise in blood HGF and TGF-beta1 levels. Rats that received hepatocyte transplantation before total hepatectomy had a significantly longer survival time than sham-transplanted anhepatic controls (34.1 +/- 8.5 vs. 15.5 +/- 4.8 hrs, P ammonia, prothrombin time, international normalized ratio, and TGF-beta1 levels when compared with sham-transplanted controls. In conclusion, intrasplenic transplantation of allogeneic hepatocytes prolonged survival, improved blood chemistry, and lowered blood TGF-beta1 levels in rats rendered anhepatic.

  5. Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design.

    Science.gov (United States)

    Yang, Soonwon; Lim, Sung A; Na, Kyung-Sun; Joo, Choun-Ki

    2017-02-01

    To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n = 97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening, IOL decentration, and capsule overlap were measured using retroillumination photospot 1 day and 2 months after cataract surgery. The area of capsule opening at postoperative day 1 was significantly different between the three IOLs (p haptic IOL (p haptic IOLs were less than those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs.

  6. Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.

    Science.gov (United States)

    Agarwal, Ashvin; Narang, Priya; Agarwal, Amar; Kumar, Dhivya A

    2014-07-01

    To characterise a sleeveless-extrusion cannula-based suction technique to levitate dislocated intraocular lens (IOLs) and review the surgical outcome. This retrospective, non-comparative, single surgeon, interventional, consecutive case series examined 10 patients (10 eyes) who underwent the surgical procedure from October 2011 to December 2012. Reliability, reproducibility, and intraoperative and postoperative complications of the technique were analysed. The technique involved suction levitation of a 3-piece acrylic foldable IOL in six cases, 1-piece acrylic foldable IOL in three cases and a plate haptic IOL in one case. The IOL was exchanged in four eyes whereas the same IOL was repositioned in six eyes with sulcus repositioning in two eyes and glued intrascleral fixation in four eyes. Intraoperative suction loss and a subsequent IOL dislocation were reported in 1 (10%) eye. Early preoperative complications included pigment dispersion in 1 (10%) eye, grade 2 anterior chamber cellular reaction in 2 (20%) eyes and intraoperative corneal oedema in 1 (10%) eye which resolved with medical line of management. Intermediate and late complications included macular oedema in one patient (10%) which resolved considerably with medical line of management. No incidence of postoperative vitreous or retinal haemorrhage, retinal break or retinal detachment was reported. The early results demonstrate this surgical intervention as a reliable, reproducible and an effective alternative treatment option for levitation of dislocated IOLs with a low complication rate.

  7. Reverse Optic Capture to Stabilize a Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Howard V. Gimbel

    2013-09-01

    Full Text Available Purpose: To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL. Method: Case report and literature review. Results: Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. Conclusions: ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.

  8. Intraocular lens explantation or exchange: indications, postoperative interventions, and outcomes

    Directory of Open Access Journals (Sweden)

    Refik Oltulu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To analyze the indications for explantation or exchange of intraocular lenses (IOLs, which were originally implanted for the correction of aphakia during cataract extraction. Methods: All cases that involved intraocular lens explantation or exchange in one institution between January 2008 and December 2014 were analyzed retrospectively. Results: In total, 93 eyes of 93 patients were analyzed. The median time interval between implantation and explantation of the anterior chamber intraocular lenses (AC IOL and posterior chamber intraocular lenses (PC IOL was 83.40 ± 83.14 months (range: 1-276 months and 55.14 ± 39.25 months (range: 1-168 months, respectively. Pseudophakic bullous keratopathy (17 eyes, 38.6% and persistent iritis (12 eyes, 27.8% in the AC IOL group and dislocation or decentration (30 eyes, 61.2% and incorrect IOL power (nine eyes, 18.4% in the PC IOL group were the most common indications for explantation of IOLs. The mean logMAR best corrected visual acuity (BCVA improved significantly from 1.30 preoperatively to 0.62 postoperatively in the PC IOL group (p<0.001 but did not improve significantly in the AC IOL group (p=0.186. Conclusions: The primary indication for IOL explantation or exchange was pseudophakic bullous keratopathy in the AC IOL group and was dislocation or decentration in the PC IOL group. PC IOL explantation or exchange is safe and improves visual acuity.

  9. An inverse and analytic lens design method

    CERN Document Server

    Lu, Yang

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input and output (object and image). The generalized Snell's law in three dimensional space and the normal of a surface in fundamental differential geometry are applied. Based on the Lagrange method equations for a single surface system are derived which can perfectly image a point object.

  10. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  11. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  12. Louvre-Lens : le Louvre autrement

    OpenAIRE

    Audrey Bodéré

    2010-01-01

    ∙ Quels sont les enjeux du projet Louvre-Lens pour le Musée du Louvre ? Par ce projet, le Louvre participe tant à la politique de décentralisation qu’à une volonté de démocratisation culturelle, en allant à la rencontre de nouveaux publics. Mais le projet scientifique et culturel du Louvre-Lens (PSC) précise aussi que l'un des principaux défis est d'oser le « Louvre autrement ». La présentation des collections est donc repensée pour traduire le monde Louvre à Lens. Le lien entre le Louvre Par...

  13. Louvre-Lens : le Louvre autrement

    Directory of Open Access Journals (Sweden)

    Audrey Bodéré

    2010-04-01

    Full Text Available ∙ Quels sont les enjeux du projet Louvre-Lens pour le Musée du Louvre ? Par ce projet, le Louvre participe tant à la politique de décentralisation qu’à une volonté de démocratisation culturelle, en allant à la rencontre de nouveaux publics. Mais le projet scientifique et culturel du Louvre-Lens (PSC précise aussi que l'un des principaux défis est d'oser le « Louvre autrement ». La présentation des collections est donc repensée pour traduire le monde Louvre à Lens. Le lien entre le Louvre Par...

  14. Image watermarking against lens flare effects

    Science.gov (United States)

    Chotikawanid, Piyanart; Amornraksa, Thumrongrat

    2017-02-01

    Lens flare effects in various photo and camera software nowadays can partially or fully damage the watermark information within the watermarked image. We propose in this paper a spatial domain based image watermarking against lens flare effects. The watermark embedding is based on the modification of the saturation color component in HSV color space of a host image. For watermark extraction, a homomorphic filter is used to predict the original embedding component from the watermarked component, and the watermark is blindly recovered by differentiating both components. The watermarked image's quality is evaluated by wPSNR, while the extracted watermark's accuracy is evaluated by NC. The experimental results against various types of lens flare effects from both computer software and mobile application showed that our proposed method outperformed the previous methods.

  15. The Frontier Fields Lens Modeling Comparison Project

    CERN Document Server

    Meneghetti, M; Coe, D; Contini, E; De Lucia, G; Giocoli, C; Acebron, A; Borgani, S; Bradac, M; Diego, J M; Hoag, A; Ishigaki, M; Johnson, T L; Jullo, E; Kawamata, R; Lam, D; Limousin, M; Liesenborgs, J; Oguri, M; Sebesta, K; Sharon, K; Williams, L L R; Zitrin, A

    2016-01-01

    Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Deriving a lens magnification map for a galaxy cluster is a classic inversion problem and many methods have been developed over the past two decades to solve it. Several research groups have developed techniques independently to map the predominantly dark matter distribution in cluster lenses. While these methods have all provided remarkably high precision mass maps, particularly with exquisite imaging data from the Hubble Space Telescope (HST), the reconstructions themselves have never been directly compared. In this paper, we report the results of comparing various independent lens modeling techniques employed by individual research groups in the community. Here we present for the first time a detailed and robust comparison of methodologies for fidelity, accuracy and precision. For this collaborative exercise, the lens modeling community was provided simulated cluster images -- of two clusters Are...

  16. Allogeneic human dermal fibroblasts are viable in peripheral blood mononuclear co-culture

    Directory of Open Access Journals (Sweden)

    Restu Syamsul Hadi

    2015-12-01

    Full Text Available BACKGROUND Transplanted allogeneic dermal fibroblasts retain stem cell subpopulations, and are easily isolated, expanded and stored using standard techniques. Their potential for regenerative therapy of chronic wounds should be evaluated. The aim of this study was to determine allogeneic fibroblast viability in the presence of peripheral blood mononuclear cells (PBMC. METHODS In this experimental study, fibroblasts were isolated from foreskin explants, expanded in the presence of serum, and stored using slow-freezing. We used one intervention group of allogeneic fibroblasts co-cultured with PBMC and 2 control groups of separate fibroblast and PBMC cultures.Fibroblasts were characterized by their collagen secretion and octamer-binding transcription factor 4 (OCT4 expression. Viability was evaluated using water soluble tetrazolium-1 (WST-1 proliferation assay. Absorbances were measured at 450 nm. Data analysis was performed by student’s paired t-test. RESULTS Dermal fibroblasts were shown to secrete collagen, express OCT4, be recoverable after cryopreservation, and become attached to the culture dish in a co-culture with PBMC. Co-cultured and control fibroblasts had no significantly different cell viabilities (p>0.05. Calculated viable cell numbers increased 1.8 and 5.1- fold, respectively, at days 2 and 4 in vitro. Both groups showed comparable doubling times at days 2 and 4 in vitro. PBMC did not interfere with allogeneic fibroblast viability and proliferative capacity CONCLUSIONS Allogeneic fibroblasts remain viable and proliferate in the presence of host PBMC. Future research should evaluate allogeneic human dermal fibroblast competency in clinical settings. Dermal fibroblasts are a potential source for cell therapy in chronic wound management.

  17. Allogeneic human dermal fibroblasts are viable in peripheral blood mononuclear co-culture

    Directory of Open Access Journals (Sweden)

    Restu Syamsul Hadi

    2014-08-01

    Full Text Available Background Transplanted allogeneic dermal fibroblasts retain stem cell subpopulations, and are easily isolated, expanded and stored using standard techniques. Their potential for regenerative therapy of chronic wounds should be evaluated. The aim of this study was to determine allogeneic fibroblast viability in the presence of peripheral blood mononuclear cells (PBMC. Methods In this experimental study, fibroblasts were isolated from foreskin explants, expanded in the presence of serum, and stored using slow-freezing. We used one intervention group of allogeneic fibroblasts co-cultured with PBMC and 2 control groups of separate fibroblast and PBMC cultures.Fibroblasts were characterized by their collagen secretion and octamer-binding transcription factor 4 (OCT4 expression. Viability was evaluated using water soluble tetrazolium-1 (WST-1 proliferation assay. Absorbances were measured at 450 nm. Data analysis was performed by student’s paired t-test. Results Dermal fibroblasts were shown to secrete collagen, express OCT4, be recoverable after cryopreservation, and become attached to the culture dish in a co-culture with PBMC. Co-cultured and control fibroblasts had no significantly different cell viabilities (p>0.05. Calculated viable cell numbers increased 1.8 and 5.1-fold, respectively, at days 2 and 4 in vitro. Both groups showed comparable doubling times at days 2 and 4 in vitro. PBMC did not interfere with allogeneic fibroblast viability and proliferative capacity Conclusions Allogeneic fibroblasts remain viable and proliferate in the presence of host PBMC. Future research should evaluate allogeneic human dermal fibroblast competency in clinical settings. Dermal fibroblasts are a potential source for cell therapy in chronic wound management.

  18. Up-to-date tools for risk assessment before allogeneic hematopoietic cell transplantation.

    Science.gov (United States)

    Elsawy, M; Sorror, M L

    2016-10-01

    Cure of malignant and non-malignant hematological diseases is potentially possible after allogeneic hematopoietic stem cell transplantation (HCT). Accurate evaluation of the risk-benefit ratio for an individual patient could improve the decision-making process about transplant, which ultimately would increase the likelihood of success. Several transplant-related models were designed in an effort to optimize decision-making about suitable candidates for allogeneic HCT. In 1998, The European Society for Blood and Marrow Transplantation (EBMT) developed a five-component pretransplantation risk scoring system for patients with CML. The EBMT score was later tested in patients with various hematological disorders, and it was shown to stratify risks of mortality after allogeneic HCT. More recent research efforts focused on models that assess health status before HCT. A HCT-specific comorbidity index was designed to assign weights to 17 relevant comorbidities that were shown to independently predict non-relapse mortality. Performance status scales and comprehensive geriatric assessment tools might uncover additional overall health limitations that affect long-term survival among older recipients of allogeneic HCT. Other models include the pretransplantation assessment of mortality score that summarizes the impacts of eight different pretransplantation patient- and disease-specific variables into a 50-point model that predicts survival. The disease-risk index captures the impact of primary diagnoses and disease status on relapse and survival following allogeneic HCT. The values and limitations of each model are discussed herein. We also provide insight on how to use these models in the clinic to decide about offering allogeneic HCT with the most suitable conditioning regimen intensity.

  19. New Management of Angle-closure Glaucoma by Phacoemulsification with Foldable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jian Ge; Yan Guo; Yizhi Liu; Mingkai Lin; Yehong Zhuo; Bing Chen; Xiuqi Chen

    2000-01-01

    Objective: To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOL) implantation. Design: Retrospective, noncontrolled interventional case series.Participants: In 36 eyes with angle-closure glaucoma (ACG), there were 18 eyes with primary acute angle-closure glaucoma (PACG), 14 eyes with primary chronic angle-closure glaucoma (PCCG), 3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle-closure glaucoma (SCCG).Intervention: Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures: Postoperative visual acuity, IOP, axial anterior chamber depth.Results: After a mean postoperative follow-up time of 8.81 ± 7.45 months, intraocular pressure was reduced from a preoperative mean of 23.81 ± 17.84 mmHg to a postoperative mean of 12.54 ± 4. 73 mmHg ( P = 0. 001 ). Mean anterior chamber depth was 1.75 ± 0.48 mm preoperatively and 2.29 ± 0.38 mm postoperatively ( P = 0. 000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0. 01 to 0. 7 (20/200 to 20/30) postoperatively, which was better than preoperative VA ranging from hand movement to 0.4 (20/50) ( P= 0. 000).Conclusion: Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma. Eye Science 2000; 16:22 ~ 28.

  20. New Management of Angle-closure Glaucoma by Phacoemulsification with Folable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    JianGE; YanGuo; 等

    2002-01-01

    Objective:To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOIL)implantation.Design:Retrospective,noncontrolled interventional case series.Participants:In 36 eyes with angle -closure glaucoma(ACG).there were 18eyes with primary acute angle-closure glaucoma(PACG),14 eyes with primary chonic angle -closure glaucoma(PCCG),3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle -closure glaucoma(SCCG).Intervention:Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures:Postoperative visual acuity,IOP,axial anterior chamber depth.Results:After a mean postoperative follow -time of 8.81±7.45 months,intraocular pressure was reduced from a preoperative mean of 23.81±17.84 mmHg to a postoperative mean of 12.54±4.73mmHg(P=0.001).Mean anterior chamber depth was 1.75±0.48 mm preoiperatively and 2.29±0.38mm postoperatively(P-0.000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0.01 to 0.7(20/200 to 20/30)postoperatively,which was better than preoperative VA ranging from hand movement to 0.4(20/50)(P=0.000).Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma.Eye Science2000;16:22-28.

  1. Analytic Models of Plausible Gravitational Lens Potentials

    Energy Technology Data Exchange (ETDEWEB)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2007-05-04

    Gravitational lenses on galaxy scales are plausibly modeled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sersic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasizing that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential.We also provide analytic formulae for the lens potentials of Sersic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modeled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses.

  2. Photonic crystal based polarization insensitive flat lens

    Science.gov (United States)

    Turduev, M.; Bor, E.; Kurt, H.

    2017-07-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a/λ  =  0.280 and a/λ  =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25λ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  3. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  4. I-131-Metaiodobenzylguanidine therapy with allogeneic cord blood stem cell transplantation for recurrent neuroblastoma

    Directory of Open Access Journals (Sweden)

    Sato Yuya

    2012-10-01

    Full Text Available Abstract Iodine-131-metaiodiobenzylguanidine (131I-MIBG therapy combined with allogeneic cord blood stem cell transplantation (SCT was used to treat a 4-year-old girl with recurrent neuroblastoma. The patient experienced relapse 2 years after receiving first-line therapies, which included chemotherapy, surgical resection, irradiation, and autologous peripheral SCT. Although 131I-MIBG treatment did not achieve complete remission, the size of the tumor was reduced after treatment. Based on our findings, we suggest that 131I-MIBG treatment with myeloablative allogeneic SCT should be considered as first-line therapy for high-risk neuroblastoma patients when possible.

  5. Allogeneic hematopoietic stem-cell transplantation for acute myeloid leukemia in remission

    DEFF Research Database (Denmark)

    Nagler, Arnon; Rocha, Vanderson; Labopin, Myriam

    2013-01-01

    Cyclophosphamide (Cy) combined with total-body irradiation (TBI) or with busulfan (Bu) are currently the most common myeloablative regimens used in allogeneic stem-cell transplantation (alloSCT) in adults with acute myelogenous leukemia (AML). Intravenous (IV) Bu has more predictable bioavailabil......Cyclophosphamide (Cy) combined with total-body irradiation (TBI) or with busulfan (Bu) are currently the most common myeloablative regimens used in allogeneic stem-cell transplantation (alloSCT) in adults with acute myelogenous leukemia (AML). Intravenous (IV) Bu has more predictable...

  6. Recurrent myelitis after allogeneic stem cell transplantation. Report of two cases

    Directory of Open Access Journals (Sweden)

    Voß Martin

    2010-09-01

    Full Text Available Abstract Background Allogeneic and autologous haematopoietic stem cell transplantation are established treatment options for haematological malignancies and may possibly be employed to treat a range of genetic and autoimmune diseases. Case presentation We report two patients who developed an acute myelitis within their thoracic spinal cord after allogeneic stem cell transplantation. Myelitis in these patients was not related to graft versus host disease or immune reconstitution and was responsive to intravenous methylprednisolone and cyclophosphamide. Conclusions Myelitis is a possibly disabling consequence of haematopoietic stem cell transplantation.

  7. Pulse transformer for the AA lithium lens

    CERN Multimedia

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  8. Time resolved thermal lens in edible oils

    Science.gov (United States)

    Albuquerque, T. A. S.; Pedreira, P. R. B.; Medina, A. N.; Pereira, J. R. D.; Bento, A. C.; Baesso, M. L.

    2003-01-01

    In this work time resolved thermal lens spectrometry is applied to investigate the optical properties of the following edible oils: soya, sunflower, canola, and corn oils. The experiments were performed at room temperature using the mode mismatched thermal lens configuration. The results showed that when the time resolved procedure is adopted the technique can be applied to investigate the photosensitivity of edible oils. Soya oil presented a stronger photochemical reaction as compared to the other investigated samples. This observation may be relevant for future studies evaluating edible oils storage conditions and also may contribute to a better understanding of the physical and chemical properties of this important foodstuff.

  9. Fundamentals of concentric lens systems synthesis

    Science.gov (United States)

    Ezhova, Kseniia; Zverev, Victor; Tochilina, Tatiana; Tymoshchuk, Irina

    2016-09-01

    Introduction of coefficients defining the relationship of the radii of curvature of the surfaces of concentric optical systems, allowed the transformation of the obtained analytical relations in a system of two equations with two unknowns. It is shown that the existence of the solution of the system of equations determined by the optical constants of the selected lens material. The results of the analysis of the conditions of the chromatic aberration correction position and the sequence of obtaining of the system equations define the theoretical basis of the engineering method of parametric synthesis of concentric lens systems. Application of the developed method is illustrated by examples of calculation particular systems design build.

  10. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  11. [Anterior skull-base schwannoma].

    Science.gov (United States)

    Esquivel-Miranda, Miguel; De la O Ríos, Elier; Vargas-Valenciano, Emmanuelle; Moreno-Medina, Eva

    2017-06-24

    Schwannomas are nerve sheath tumours that originate in Schwann cells. They are usually solitary and sporadic and manifest on peripheral, spinal or cranial nerves. Intracranial schwannomas tend to manifest on the eighth cranial nerve, particularly in patients with neurofibromatosis type2. Anterior skull-base schwannomas represent less than 1% of all intracranial schwannomas. They are more frequent in young people and are typically benign. These tumours represent a diagnostic challenge due to their rarity and difficult differential diagnosis, and numerous theories have been postulated concerning their origin and development. In this article, we present the case of a 13-year-old male with a single anterior cranial-base tumour not associated with neurofibromatosis who presented with headache, papilloedema, eye pain and loss of visual acuity. Complete resection of the tumour was performed, which was histopathologically diagnosed as a schwannoma. The patient made a complete clinical recovery with abatement of all symptoms. We conducted a review of the literature and found 66 cases worldwide with this diagnosis. We describe the most relevant epidemiological and clinical characteristics of this kind of tumour and its relation with the recently discovered and similar olfactory schwannoma. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Anterior chest wall examination reviewed

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the “activity” of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  13. Truly simultaneous SS-OCT of the anterior and posterior human eye with full anterior chamber and 50° retinal field of views (Conference Presentation)

    Science.gov (United States)

    McNabb, Ryan P.; Viehland, Christian; Keller, Brenton; Vann, Robin R.; Izatt, Joseph A.; Kuo, Anthony N.

    2017-02-01

    Optical coherence tomography (OCT) has revolutionized clinical observation of the eye and is an indispensable part of the modern ophthalmic practice. Unlike many other ophthalmic imaging techniques, OCT provides three-dimensional information about the imaged eye. However, conventional clinical OCT systems image only the anterior or the posterior eye during a single acquisition. Newer OCT systems have begun to image both during the same acquisition but with compromises such as limited field of view in the posterior eye or requiring rapid switching between the anterior and posterior eye during the scan. We describe here the development and demonstration of an OCT system with truly simultaneous imaging of both the anterior and posterior eye capable of imaging the full anterior chamber width and 50° on the retina (macula, optic nerve, and arcades). The whole eye OCT system was developed using custom optics and optomechanics. Polarization was utilized to separate the imaging channels. We utilized a 200kHz swept-source laser (Axsun Technologies) centered at 1040±50nm of bandwidth. The clock signal generated by the laser was interpolated 4x to generate 5504 samples per laser sweep. With the whole eye OCT system, we simultaneously acquired anterior and posterior segments with repeated B-scans as well as three-dimensional volumes from seven healthy volunteers (other than refractive error). On three of these volunteers, whole eye OCT and partial coherence interferometry (LenStar PCI, Haag-Streit) were used to measure axial eye length. We measured a mean repeatability of ±47µm with whole eye OCT and a mean difference from PCI of -68µm.

  14. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  15. Experimental Contact Lens to Prevent Glaucoma-Induced Blindness

    Science.gov (United States)

    ... Home Page An Experimental Contact Lens to Prevent Glaucoma-Induced Blindness By Sharon Reynolds Posted January 23, 2014 An experimental contact lens design releases a glaucoma medicine at a steady rate for up to ...

  16. Ophthoselfie: Detailed Self-imaging of Cornea and Anterior Segment by Smartphone

    Directory of Open Access Journals (Sweden)

    Abdullah Kaya

    2017-06-01

    Full Text Available Objectives: To describe the ophthoselfie, a method by which everyone can take detailed self-images of the cornea and anterior segment with a smartphone. Materials and Methods: A 90-diopter non-contact double aspheric lens was attached to posterior camera of the smartphone by clear tape. Images of one eye on the screen of the smartphone could be seen with the other eye in the mirror and images were taken. Results: Accurate and detailed images of the cornea and anterior segment of the eye could be taken. Conclusion: The ophthoselfie allows everyone to take their own detailed anterior segment images by smartphone. To create a clear and detailed self-image of the cornea and anterior segment on the screen of a smartphone may lead to the development of new applications and facilitate patients’ early recognition of certain conditions like keratoconus, refractive errors, corneal rejection, and uveitis. This method may also be useful in some urgent situations by allowing patients to take self-images of the eye and share them with a physician.

  17. Ophthoselfie: Detailed Self-imaging of Cornea and Anterior Segment by Smartphone.

    Science.gov (United States)

    Kaya, Abdullah

    2017-06-01

    To describe the ophthoselfie, a method by which everyone can take detailed self-images of the cornea and anterior segment with a smartphone. A 90-diopter non-contact double aspheric lens was attached to posterior camera of the smartphone by clear tape. Images of one eye on the screen of the smartphone could be seen with the other eye in the mirror and images were taken. Accurate and detailed images of the cornea and anterior segment of the eye could be taken. The ophthoselfie allows everyone to take their own detailed anterior segment images by smartphone. To create a clear and detailed self-image of the cornea and anterior segment on the screen of a smartphone may lead to the development of new applications and facilitate patients' early recognition of certain conditions like keratoconus, refractive errors, corneal rejection, and uveitis. This method may also be useful in some urgent situations by allowing patients to take self-images of the eye and share them with a physician.

  18. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    Directory of Open Access Journals (Sweden)

    Emre Güler

    2014-03-01

    Full Text Available Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalmol 2014; 44: 156-7

  19. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    OpenAIRE

    Emre Güler; Aylin Tenlik; Tuba Kara Akyüz

    2014-01-01

    Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalm...

  20. Lens autofluorescence is not increased at high altitude

    DEFF Research Database (Denmark)

    Kessel, Line; Kofoed, Peter Kristian; Zubieta-Calleja, Gustavo

    2010-01-01

    PURPOSE: To study the relation between ambient environmental ultraviolet radiation exposure and lens fluorescence. METHODS: Non-invasive lens fluorometry measurements were compared in healthy Bolivian and Danish subjects. Background ultraviolet radiation was 4.5 times higher in Bolivia than...... in Denmark. RESULTS: No significant differences in lens fluorescence or transmittance were found between Bolivian and Danish volunteers. CONCLUSION: Age-corrected lens fluorescence and transmittance were comparable for healthy participants living at high altitude near the equator and healthy volunteers...

  1. An Ultrasonic Lens Design Based on Prefractal Structures

    OpenAIRE

    Sergio Castiñeira-Ibáñez; Daniel Tarrazó-Serrano; Constanza Rubio; Pilar Candelas; Antonio Uris

    2016-01-01

    The improvement in focusing capabilities of a set of annular scatterers arranged in a fractal geometry is theoretically quantified in this work by means of the finite element method (FEM). Two different arrangements of rigid rings in water are used in the analysis. Thus, both a Fresnel ultrasonic lens and an arrangement of rigid rings based on Cantor prefractals are analyzed. Results show that the focusing capacity of the modified fractal lens is better than the Fresnel lens. This new lens is...

  2. Imaging findings of anterior hip dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Kyle [Mallinckrodt Institute of Radiology, Department of Radiology, St. Louis, MO (United States); Leslie, Michael [Yale School of Medicine, Department of Orthopedics and Rehabilitation, New Haven, CT (United States); Menn, Kirsten; Haims, Andrew [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-06-15

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  3. Positioning of anterior teeth in removable dentures

    Directory of Open Access Journals (Sweden)

    Strajnić Ljiljana

    2002-01-01

    Full Text Available Introduction The aim of this paper was to present methods of placement of artificial anterior teeth in edentulous individuals. The following review takes account of the majority of papers published during the last 100 years. The review has been divided into sections regarding the method used to determine the position of artificial anterior teeth. Geometric aspect Gysi (1895-1920 produced the first scientific theory about the position of artificial anterior teeth. Physiognomic theory The aim of this theory is to find the most natural position for artificial anterior teeth for each individual. Camper's "face angle" as a physiognomic criterion, has been introduced in papers of Wehrli (1961, Marxhors (1966, Tanzer (1968, Lombardi (1973. Esthetic aspect Important names in the field of dental esthetics are: Schön and Singer (1961, Arnheim (1965, Krajiček (1969, Tanzer (1968, Lombardi (1973, Goldstein (1976. They have introduced principles of visual aspects for selection of contours, dimension and position of artificial anterior teeth. Constitution aspect Flagg (1880, Williams (1913 and Hrauf (1957, 1958, have considered body constitution and individual characteristics regarding position of artificial anterior teeth. Physiological theory In 1971, Marxhors pointed to the fact that the position of artificial teeth corresponds with the function of the surrounding soft tissue and from the aspect of physiognomy as well. Phonetic aspect According to Silverman (1962 artificial anterior teeth are nearest when we pronounce the sound "S". Cephalometrical research Rayson (1970, Watson (1989, Strajnić Lj. (1999, Bassi F. (2001 have presented cephalometric radiographic analyses of natural anterior teeth compared with cephalometric radiographic analyses of artificial anterior teeth. A review of dental literature shows several factors suggesting modalities which should determine the position of artificial anterior teeth. Numerous methods have been designed for

  4. Incidental Anterior Cruciate Ligament Calcification: Case Report.

    Science.gov (United States)

    Hayashi, Hisami; Fischer, Hans

    2016-03-01

    The calcification of knee ligaments is a finding noted only in a handful of case reports. The finding of an anterior cruciate ligament calcification has been reported once in the literature. Comparable studies involving the posterior cruciate ligament, medial collateral ligament and an ossicle within the anterior cruciate ligament are likewise discussed in reports of symptomatic patients. We report a case of incidentally discovered anterior cruciate ligament calcification. We discuss the likely etiology and clinical implications of this finding.

  5. Iris Claw versus Scleral Fixation Intraocular Lens Implantation during Pars Plana Vitrectomy

    Directory of Open Access Journals (Sweden)

    Fereydoun Farrahi

    2012-01-01

    Full Text Available Purpose: To compare the outcomes of iris claw anterior chamber intraocular lens (ICACIOL with that of scleral fixation posterior chamber intraocular lens (SF-PCIOL implantation during pars plana vitrectomy (PPV as initial surgery to correct aphakia. Methods: Twelve patients with complicated cataract surgery or trauma who had suffered nucleus, whole crystalline lens or intraocular lens (IOL drop into the vitreous cavity, and undergone PPV with IC-ACIOL implantation over a period of one year were evaluated for the purpose of this study. Uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA, central corneal thickness (CCT, spherical equivalent (SE refractive error, astigmatism and complications were recorded. The results were compared to outcomes of another group of 13 patients who had previously undergone PPV with SF-PCIOL implantation. Results: Mean improvement of UCVA was greater in IC-ACIOL eyes as compared to the SF-PCIOL group (-1.17±0.28 versus -0.89±0.21 logMAR, P=0.01, corresponding values for postoperative BCVA were 0.24±0.17 and 0.44±0.22 logMAR (P=0.041, respectively. Average postoperative SE was comparable in the IC-ACIOL and SFPCIOL groups at 0.6±1.03 and 0.56±1.23 diopters, respectively (P=0.290. However, 10 (83.3% IC-ACIOL eyes versus 6 (46.1% SF-PCIOL eyes had SE within 1 diopter of emmetropia (P=0.048. Mean postoperative increase in CCT was comaparble between the study groups (P=0.126. Conclusion: In the absence of sufficient capsular support, the use of an IC-ACIOL for correction of aphakia during PPV can be a good alternative and seems to entail better visual outcomes as compared to SF-PCIOL.

  6. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device...

  7. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  8. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that...

  9. Intraocular Lens Opacification following Intracameral Injection of Recombinant Tissue Plasminogen Activator to Treat Inflammatory Membranes after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Simon S. M. Fung

    2015-01-01

    Full Text Available Purpose. To report 7 cases of intraocular lens (IOL opacification following treatment of postoperative anterior chamber fibrin with recombinant tissue plasminogen activator (rtPA after cataract surgery. Methods. Retrospective case series of 7 eyes in 7 patients who developed IOL opacification after receiving rtPA for anterior chamber inflammatory membrane formation resulting from phacoemulsification cataract surgery. Three explanted IOLs were investigated with light microscopy, histochemical analysis, scanning electron microscopy, and X-ray spectrometry. Results. All patients underwent uncomplicated cataract surgery and posterior chamber hydrophilic IOL implantation. Anterior chamber inflammatory membranes developed between 1 and 4 weeks of surgery and were treated with intracameral rtPA. IOL opacification was noted between 4 weeks and 6 years after rtPA treatment with reduced visual acuity, and IOL exchange was carried out in 3 patients. Light microscopy evaluation revealed diffuse fine granular deposits on the anterior surface/subsurface of IOL optic that stained positive for calcium salts. Scanning electron microscopy (SEM and energy-dispersive X-ray spectrometry (EDS confirmed the presence of calcium and phosphate on the IOL. Conclusions. Intracameral rtPA, though rapidly effective in the treatment of anterior chamber inflammatory membranes following cataract surgery, may be associated with IOL opacification.

  10. 可植入接触镜屈光手术后调节与拱高的关系%Relationship between accommodation and lens vault following implantable contact lens surgery

    Institute of Scientific and Technical Information of China (English)

    赖晓娟; 李志敏; 谷浩

    2014-01-01

    Background Implantable contact lens (ICL) surgery is a primary intraocular refractive corrective surgery for high myopia.However,whether there will be enough distance between ICL and anterior face of lens to avoid the occurrence of anterior capsular cataract in non-accommodated and the largest physiological accommodated state after ICL implantation is worthy of investigation.Objective The purpose of this study was to investigate the alteration of lens vault after ICL implantation and explore the relationship between accommodation and change of lens vault.Methods A observational study was carried out.Sixty-six eyes of 33 patients with high myopia who received ICL implantation were enrolled in Affiliated First Hospital of Guiyang Medical College from May to November,2012.Best corrected visual acuity (BCVA),uncorrected visual acuity (UCVA),refractive diopter were regularly examined using synthetical optometry,and crystalline lens rise (CLR) and lens vault in non-accommodative or accommodative condition were observed by the anterior segment OCT (Visante OCT) and ultrasound biomicoscopy (UBM) before operation and 1 day,1 week,l month and 3 months after operation.Data were analyzed with SPSS version 16.0.Repeated measurement one-way analysis of variance was used to compare the differences of vision and refractive diopter among various time points.The relationship between accommodation and CLR was assessed using Pearson linear correlation.The alteration of CLR with accommodation change was analyzed by linear regression equation.Lens vault was measured and compared between non-accommodation and maximal physical accommodation status by paired t test.Results The postoperative UCVA was improved in comparison with preoperative BCVA,and the postoperative diopter was significantly lower than that of preoperation,with significant differences among various time points (F =16.904,P =0.000 ; F =1.498,P =0.000),and the diopter was stable after operation.A positive correlation was

  11. Analysis on shift and rotation of intraocular lens after phakic collamer lens implantation

    National Research Council Canada - National Science Library

    Yuan-Yuan Lu; Na Yang; Xue-Dong Li; Jun Kong

    2016-01-01

    .... In 1993, Staar Surgical(A.G. Nidau)introduced a modified intraocular collamer lens(ICL)for the correction of high myopia, which emerged as a safe and effective operation for moderate or high myopia gradually...

  12. Contact lens wear and microbial keratitis.

    Science.gov (United States)

    Ahuja, Markanday

    2002-11-01

    Common types of contact lens are hard, rigid gas-permeable or soft lenses. Most lenses are worn on a daily basis. Cosmetic lenses are worn for non-medical indications. Microbial keratitis, a rare but most significant complication is discussed in this article. Pseudomonas aeruginosa and staphylococci are the most common organisms cause infective keratitis. Fungi and acanthamoeba are also responsible. The causes of increased susceptibility to infection are poor lens hygiene, adhesion of bacteria to lens surface and hypoxia. Preventing measures to be taken while wearing contact lens are discussed in a nutshell. Ocular pain, conjunctival infection, photophobia, epiphora and reduced vision are some of the symptoms of corneal infection. Diagnostic laboratory investigations are to be carried out immediately when a microbial corneal ulcer is suspected. Acanthamoeba can be cultured from corneal scrapes. Immunologically based fluorescein labelling techniques appear to be more sensitive than simple staining. The treatment consists of medical and surgical intervention. Corneal thinning, descemetocele formation and perforation are possible complications.

  13. Application of optical polymers in lens design

    Science.gov (United States)

    Sultanova, Nina; Kasarova, Stefka; Nikolov, Ivan

    2016-03-01

    Optical, some thermal and elastic properties of optical polymers which are of importance in lens design are considered. Results are based on precise measurement of refraction of materials. Ultrasonic investigation of elastic moduli is carried out. Comparison to properties of Schott glasses is accomplished. Examples on the design of all-plastic and hybrid glass-plastic systems are presented.

  14. Testing and inspecting lens by holographic means

    Science.gov (United States)

    Hildebrand, Bernard P.

    1976-01-01

    Processes for the accurate, rapid and inexpensive testing and inspecting of oncave and convex lens surfaces through holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and said convex surfaces to be so tested.

  15. Lens testing using total internal reflection holography

    Science.gov (United States)

    Hildebrand, Bernard P.

    1976-12-14

    Accurate, rapid and inexpensive testing and inspecting of lens surfaces tugh holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and convex surfaces to be so tested.

  16. Contact lens rehabilitation following repaired corneal perforations

    Directory of Open Access Journals (Sweden)

    Sreenivas V

    2006-03-01

    Full Text Available Abstract Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60% required aphakic contact lenses. The best corrected visual acuity (BCVA of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25% eyes with spectacle correction and 37 (92.5% eyes with the use of contact lens (p Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries.

  17. Magnifying perfect lens with positive refraction

    CERN Document Server

    Tyc, Tomas

    2010-01-01

    We propose a device with a positive isotropic refractive index that creates a magnified perfect real image of an optically homogeneous three-dimensional region of space within geometrical optics. Its key ingredient is a new refractive index profile that can work as a perfect lens on its own, having a very moderate index range.

  18. Solar powered desalination system using Fresnel lens

    Science.gov (United States)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  19. Intraocular lens in a fighter aircraft pilot.

    OpenAIRE

    Loewenstein, A; Geyer, O; Biger, Y; Bracha, R; Shochat, I; Lazar, M.

    1991-01-01

    A pseudophakic pilot of the Israeli air force flying an F-15 (Eagle) aircraft was followed up for three years. He experienced about 100 flying hours, 5% of the time under high g stress. The intraocular lens did not dislocate and no complications were observed. It seems that flying high performance fighter aircraft is not contraindicated in pseudophakic pilots.

  20. High Accuracy Dual Lens Transmittance Measurements

    Science.gov (United States)

    2007-08-01

    measurement of lens transmission,” Metrologia 37, 603–605 (2000). 3. B. Munro, “Quantum information processing with light and its requirement for detectors...5. N. P. Fox, “Trap detectors and their properties,” Metrologia 28, 197–202 (1991). 5402 APPLIED OPTICS Vol. 46, No. 22 1 August 2007 6. S. L

  1. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients

    OpenAIRE

    Tomris Sengor; Sevda Aydin Kurna; Suat Aki; et al

    2011-01-01

    Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients.Methods: Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen tran...

  2. Minus Piggyback Lens Overlaying ReSTOR® Multifocal Lens in High Myopia

    Directory of Open Access Journals (Sweden)

    Isha Gupta

    2013-06-01

    Full Text Available Background: We report the case of a 40-year-old female patient treated with implantation of the Acrysof® IQ ReSTOR® lens (Alcon, Fort Worth, Tex., USA with overlaying Acrysof EXpand® minus piggyback lens (Alcon. Methods: The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral placement of the ReSTOR multifocal lens. The necessary intraocular lens (IOL power was +3.5 in the right eye and +4.0 in the left eye, though the range of commercially available ReSTOR lenses is +6.0 to +34.0 D. In order to achieve emmetropia in this case of high myopia, it was determined that an EXpand minus piggyback lens would be necessary. Results: Implantation of the ReSTOR lens with overlaying EXpand minus piggyback lens was performed successfully and without complication. At 5 months postoperatively, the patient had 20/20 uncorrected visual acuity in both eyes. She reported a high level of satisfaction and was able to return to her daily activities including reading and driving without spectacles. Conclusion: We report successful primary implantation of AcrySof EXpand minus piggyback lenses overlying the AcrySof IQ ReSTOR lens in a patient with high myopia. Long-term follow-up and further evaluation is necessary to establish piggyback IOL implantation with multifocal IOL as an accepted treatment for high myopia with presbyopia.

  3. Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography.

    Science.gov (United States)

    He, Wenwen; Zhu, Xiangjia; Wolff, Don; Zhao, Zhennan; Sun, Xinghuai; Lu, Yi

    2016-01-01

    Purpose. To evaluate the anterior chamber volume in cataract patients with Swept-Source Optical Coherence Tomography (SS-OCT) and its influencing factors. Methods. Anterior chamber volume of 92 cataract patients was evaluated with SS-OCT in this cross-sectional study. Univariate analyses and multiple linear regression were used to investigate gender, age, operated eye, posterior vitreous detachment, lens opacity grading, and axial length (AXL) related variables capable of influencing the ACV. Results. The average ACV was 139.80 ± 38.21 mm(3) (range 59.41 to 254.09 mm(3)). The average ACV was significantly larger in male patients than in female patients (P = 0.001). ACV was negatively correlated with age and LOCS III cortical (C) grading of the lens (Pearson's correlation analysis, r = -0.443, P ACV was also increased with AXL (Pearson's correlation analysis, r = 0.552, P ACV (F = 10.252  P ACV varied significantly among different subjects. Influencing factors that contribute to reduced ACV were female gender, increased age, LOCS III C grade, and shorter AXL.

  4. Imaging the anterior eye with dynamic-focus swept-source optical coherence tomography

    Science.gov (United States)

    Su, Johnny P.; Li, Yan; Tang, Maolong; Liu, Liang; Pechauer, Alex D.; Huang, David; Liu, Gangjun

    2015-12-01

    A custom-built dynamic-focus swept-source optical coherence tomography (SS-OCT) system with a central wavelength of 1310 nm was used to image the anterior eye from the cornea to the lens. An electrically tunable lens was utilized to dynamically control the positions of focusing planes over the imaging range of 10 mm. The B-scan images were acquired consecutively at the same position but with different focus settings. The B-scan images were then registered and averaged after filtering the out-of-focus regions using a Gaussian window. By fusing images obtained at different depth focus locations, high-resolution and high signal-strength images were obtained over the entire imaging depth. In vivo imaging of human anterior segment was demonstrated. The performance of the system was compared with two commercial OCT systems. The human eye ciliary body was better visualized with the dynamic-focusing SS-OCT system than using the commercial 840 and 1310 nm OCT systems. The sulcus-to-sulcus distance was measured, and the result agreed with that acquired with ultrasound biomicroscopy.

  5. Ultraviolet absorption by contact lenses and the significance on the ocular anterior segment.

    Science.gov (United States)

    Chandler, Heather

    2011-07-01

    It is well established that both acute and chronic ultraviolet (UV) exposure can lead to various ophthalmic pathologic conditions in the anterior segment. Several scientific studies have demonstrated that after UV exposure, the unprotected cornea is vulnerable to damage in the epithelial, stromal, and endothelial cellular layers. DNA damage, apoptosis, and altered protease expression are all examples of harmful changes that can occur within the cornea after irradiation. Beyond the cornea, damage associated with UV exposure, such as decreased antioxidant levels and increased reactive oxygen species production, has been noted in the aqueous humor and crystalline lens. Ultraviolet-blocking contact lenses have the potential to provide protection against such exposure to harmful UV radiation. Experimental use of UV-absorbing contact lenses prevented detrimental cellular changes to the cornea and maintained corneal clarity after UV exposure. Additionally, studies suggest that shielding the aqueous humor and crystalline lens from irradiation with UV-absorbing contact lenses aids in protection against precataractous changes. Despite ongoing research, to date, neither chronic nor clinical studies have been performed in humans to demonstrate that wearing UV-blocking contact lenses reduces the risk of developing cataracts or other ocular disorders within the anterior segment. This article will discuss the impact of UV exposure on ocular tissue and the need for adequate UV protection, with particular emphasis on UV-blocking contact lenses.

  6. Unilateral anterior ischemic optic neuropathy

    DEFF Research Database (Denmark)

    Herbst, Kristina; Sander, Birgit; Lund-Andersen, Henrik

    2013-01-01

    The intrinsically photosensitive retinal ganglion cells (ipRGCs) express the photopigment melanopsin, which is sensitive to blue light. Previous chromatic pupillometry studies have shown that the post-illumination response is considered an indicator of the melanopsin activation. The aim......-affected eyes, compared with the non-affected fellow eyes, suggesting dysfunction of the ipRGCs. Compared with the responses of the healthy controls, the blue light post-illumination pupil responses were similar in the affected eyes and increased in the fellow non-affected eyes. This suggests a possible...... of this study was to investigate the ipRGC mediated pupil response in patients with a unilateral non-arteritic anterior ischemic optic neuropathy (NAION). Consensual pupil responses during and after exposure to continuous 20 s blue (470 nm) or red (660 nm) light of high intensity (300 cd/m(2)) were recorded...

  7. Toxic Anterior Segment Syndrome (TASS

    Directory of Open Access Journals (Sweden)

    Özlem Öner

    2011-12-01

    Full Text Available Toxic anterior segment syndrome (TASS is a sterile intraocular inflammation caused by noninfectious substances, resulting in extensive toxic damage to the intraocular tissues. Possible etiologic factors of TASS include surgical trauma, bacterial endotoxin, intraocular solutions with inappropriate pH and osmolality, preservatives, denatured ophthalmic viscosurgical devices (OVD, inadequate sterilization, cleaning and rinsing of surgical devices, intraocular lenses, polishing and sterilizing compounds which are related to intraocular lenses. The characteristic signs and symptoms such as blurred vision, corneal edema, hypopyon and nonreactive pupil usually occur 24 hours after the cataract surgery. The differential diagnosis of TASS from infectious endophthalmitis is important. The main treatment for TASS formation is prevention. TASS is a cataract surgery complication that is more commonly seen nowadays. In this article, the possible underlying causes as well as treatment and prevention methods of TASS are summarized. (Turk J Oph thal mol 2011; 41: 407-13

  8. Preventive role of lens antioxidant defense mechanism against riboflavin-mediated sunlight damaging of lens crystallins.

    Science.gov (United States)

    Anbaraki, Afrooz; Khoshaman, Kazem; Ghasemi, Younes; Yousefi, Reza

    2016-10-01

    The main components of sunlight reaching the eye lens are UVA and visible light exerting their photo-damaging effects indirectly by the aid of endogenous photosensitizer molecules such as riboflavin (RF). In this study, lens proteins solutions were incubated with RF and exposed to the sunlight. Then, gel mobility shift analysis and different spectroscopic assessments were applied to examine the structural damaging effects of solar radiation on these proteins. Exposure of lens proteins to direct sunlight, in the presence of RF, leads to marked structural crosslinking, oligomerization and proteolytic instability. These structural damages were also accompanied with reduction in the emission fluorescence of Trp and Tyr and appearance of a new absorption peak between 300 and 400nm which can be related to formation of new chromophores. Also, photo-oxidation of lens crystallins increases their oligomeric size distribution as examined by dynamic light scattering analysis. The above mentioned structural insults, as potential sources of sunlight-induced senile cataract and blindness, were significantly attenuated in the presence of ascorbic acid and glutathione which are two important components of lens antioxidant defense system. Therefore, the powerful antioxidant defense mechanism of eye lens is an important barrier against molecular photo-damaging effects of solar radiations during the life span. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Analysis of fiber lens with gradient index based on thin lens equivalence

    Institute of Scientific and Technical Information of China (English)

    ZHANG Rui-feng; GE Chun-feng; LI Shi-chen

    2006-01-01

    Theoretical analysis of the fiber-lens TEC (Thermally Expended Core) /Coreless/GRIN (Graded-Index) based on thin lens equivalence is presented in this paper.On condition that the TEC part adjusts the waist radius of an incident Gaussian beam,that the coreless part controlls the space between the beam waist and the thin lens,and that the GRIN part acts as the thin lens with its focal length determined by fiber index distribution parameter g,the analytic expressions of the waist spot size and the working distance of the output Gaussian beam are derived,and the influence of the coreless fiber and the length of the GRIN fiber upon the fiber-lens parameter is discussed based on the numerical simulation results.It is concluded that,if a GRIN style fiber-lens is used as a collimator,the maximum of the spot waist can be up to 80 μm and the divergence angle of single-mode optical fiber can be reduced by 8 times.If it is applied to a MEMS device, the maximum working distance can be up to 3 mm.

  10. [Effect of ocular compression on anterior chamber dimensions in cataract surgery using topical anaesthesia].

    Science.gov (United States)

    Wirbelauer, C; Pham, D T

    2014-10-01

    Ocular compression is part of the preparation before cataract surgery to reduce the incidence of a positive intraoperative pressure. The purpose of this clinical study was to assess the influence of ocular compression on the anterior chamber dimensions and biometric parameters before cataract surgery using topical anaesthesia. In a prospective, comparative observational study the biometric parameters were assessed with slitlamp-adapted anterior segment OCT (SL-OCT, Heidelberg Engineering) and ultrasound biometry (A-Scan+, Sonomed) in 51 consecutive patients (51 eyes) with a mean axial eye length of 22.90 ± 1.05 mm before cataract surgery. The measurements were performed in all patients before and immediately after ocular compression (Oculopressor G-15392, Geuder). In 32 patients the measurements were repeated 10 minutes after ocular compression. The optical and acoustic values of the anterior chamber depth did not change significantly after ocular compression (p > 0.05). Digital gonioscopy with OCT revealed a mean increase of the anterior chamber angle of 2.37° (p < 0.001) from 45.75 ± 7.28° to 48.12 ± 7.28°, and the angle opening distance of 37 µm (p = 0.017) from 627 ± 184 µm to 664 ± 162 µm. Also the average acoustic axial vitreous distance decreased significantly from 15.22 ± 0.98 to 15.18 ± 0.96 mm (p = 0.034) with a posterior shift in the relative lens position (p = 0.018). In this clinical study, only slight anterior chamber and biometric changes were observed after ocular compression before cataract surgery using topical anaesthesia. There was a significant increase of the anterior chamber angle and angle opening distance with a concomitant decrease of the vitreous distance and shifting of the iris lens diaphragm. Georg Thieme Verlag KG Stuttgart · New York.

  11. Allogeneic Immunotherapy for Relapsed Multiple Myeloma:Role of Matched Unrelated Donors

    Institute of Scientific and Technical Information of China (English)

    M.Goerner; S.Hoepfner; 等

    2002-01-01

    Existence of a graft-versus-myeloma effect has been well documented by responses to donor lymphocyte infusions and long-term survival after allogeneic bone marrow transplantation.The development of non-myeloablative conditioning regimens allows utilization of allogeneic effects in patients usually not suitable for myeloablative allogeneic transplantation,such as older and heavily pretreated pa-tients.In a small series of 11 patients with multiple myeloma relapsing after autologous transplantation,we show that conditioning with low-dose total body irradiation in combination with fludarabine allows stable engraftment after matched unrelated donor transplantation and is tolerated with acceptable transplant-related morbidity and mortality.With a short median follow-up of 225 days,disease control was achieved only for patients responding to conventional treatment prior to allografting .Future studies with longer follow-up have to define the role of non-myeloablative allogeneic transplantation from unrelated donors as consolidation for patients responding to salvage therapy.

  12. Thiotepa improves allogeneic bone marrow engraftment without enhancing stem cell depletion in irradiated mice

    NARCIS (Netherlands)

    Down, JD; Westerhof, GR; Boudewijn, A; Setroikromo, R; Ploemacher, RE

    1998-01-01

    Thiotepa (TT) has long been considered for inclusion in clinical bone marrow transplant (BMT) conditioning regimens in an attempt to prevent allograft rejection and leukemia relapse, These studies have been encouraged by initial murine experiments showing a clear improvement in allogeneic bone marro

  13. Relapse of lymphoma after allogeneic hematopoietic cell transplantation: management strategies and outcome.

    Science.gov (United States)

    Wudhikarn, Kitsada; Brunstein, Claudio G; Bachanova, Veronika; Burns, Linda J; Cao, Qing; Weisdorf, Daniel J

    2011-10-01

    The outcome and management of relapsed lymphoma after allogeneic hematopoietic cell transplantation (HCT) is difficult. Therapeutic options may include donor lymphocyte infusion (DLI), reduction of immunosuppression (RIS), chemotherapy, radiation, immunotherapy, second HCT, and experimental treatments, but reported data contrasting the response and efficacy of these salvage treatments are limited. We describe the treatments, response, prognosis, and long-term survival of 72 patients with relapse of lymphoma after allogeneic HCT. Between 1991 and 2007, 227 lymphoma patients underwent allogeneic HCT. Of these, 72 (32%) developed relapse/progression after their HCT at a median of 99 days (0-1898 days); 37 had early (100 days) post-HCT. Three-year survival after HCT was significantly better in late than early relapse (53%; 95% confidence interval [CI] [34%-69%] versus 36%, [20%-52%], P = .02). Of 72 relapsed patients, 29 (40%) survived at a median of 34 (3-148) months posttransplant. The most common cause of death was underlying lymphoma (79%). The overall prognosis of relapsed/progressive lymphoma after allogeneic HCT is disappointing, yet half of patients respond to withdrawal of immunosuppression and additional therapies. Novel treatments can control lymphoma with acceptable morbidity. Particularly for patients with later relapse, ongoing treatment after relapse can yield meaningful benefit and prolonged survival.

  14. Graft-versus-host disease and graft-versus-tumor effects after allogeneic hematopoietic cell transplantation

    DEFF Research Database (Denmark)

    Storb, Rainer; Gyurkocza, Boglarka; Storer, Barry E

    2013-01-01

    We designed a minimal-intensity conditioning regimen for allogeneic hematopoietic cell transplantation (HCT) in patients with advanced hematologic malignancies unable to tolerate high-intensity regimens because of age, serious comorbidities, or previous high-dose HCT. The regimen allows the pures...

  15. Specific Factors Influence the Success of Autologous and Allogeneic Hematopoietic Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Thissiane L. Gonçalves

    2009-01-01

    Full Text Available Successful hematopoietic stem cell transplantation (HSCT, both autologous and allogeneic, requires a rapid and durable engraftment, with neutrophil (>500/µL and platelet (>20,000/µL reconstitution. Factors influencing engraftment after autologous or allogeneic HSCT were investigated in 65 patients: 25 autologous peripheral stem cell transplantation (PBSCT and 40 allogeneic bone marrow transplantation (BMT patients. The major factor affecting engraftment was the graft source for HSCT. Neutrophil and platelet recovery were more rapid in autologous PBSCT than in allogeneic BMT [neutrophil occurring in median on day 10.00 (09.00/11.00 and 19.00 (16.00/23.00 and platelet on day 11.00 (10.00/13.00 and 21.00 (18.00/25.00, respectively; p < 0.0001]. The type of disease also affected engraftment, where multiple myeloma (MM and lymphoma showed faster engraftment when compared with leukemia, syndrome myelodysplastic (SMD and aplastic anemia (AA and MM presented the best overall survival (OS in a period of 12 months. Other factors included the drug used in the conditioning regimen (CR, where CBV, melphalan (M-200 and FluCy showed faster engraftment and M-200 presented the best OS, in a period of 12 months and age, where 50–59 years demonstrated faster engraftment. Sex did not influence neutrophil and platelet recovery.

  16. Expression of membrane-bound burst-promoting activity is mediated by allogeneic effector cells.

    Science.gov (United States)

    Guha, A; Tuck, D; Sorba, S; Dainiak, N

    1993-09-01

    To investigate whether "self" and "non-self" recognition processes are involved in murine erythropoiesis, the expression of membrane-bound burst-promoting activity (mBPA) was determined for B lymphocytes purified from spleens of CF-1, C57 BL/6J, B6021-7115, and CAF-1J mice using syngeneic and allogeneic bone marrow cultures. Addition of B lymphocyte conditioned medium (LCM), shed membrane-derived vesicles, or intact plasma membranes prepared from syngeneic murine cells stimulated erythroid burst-forming unit (BFU-E) proliferation by two- to three-fold above control levels. BFU-E proliferation was increased by six- to eight-fold, however, when LCM, shed membrane vesicles, or plasma membranes purified from allogenic B lymphocytes were used as sources of growth-stimulatory activity. Bioactivity was immunoprecipitated from detergent extracts of membranes purified from both allogeneic and syngeneic lymphocytes with a monoclonal antibody that specifically recognizes mBPA, suggesting that the factors expressed by these cells share antigenic determinants. The results indicate that allogeneic effector cells are a more potent source of mBPA-like molecules than are syngeneic cells, suggesting that immune mechanisms may be involved in inducing erythroid growth factor expression at the B cell surface.

  17. Gastrointestinal toxicity, systemic inflammation, and liver biochemistry in allogeneic hematopoietic stem cell transplantation

    Science.gov (United States)

    Liver toxicity is frequently seen in relation to allogeneic hematopoietic stem cell transplantation (HSCT), but pathogenesis and the risk factors are poorly understood. The purpose of this study was to investigate associations between liver toxicity, gastrointestinal toxicity, and levels of immune-r...

  18. Retrospective analysis of fluoroquinolone prophylaxis in patients undergoing allogeneic hematopoietic stem cell transplantation.

    Science.gov (United States)

    Simondsen, Katherine A; Reed, Michael P; Mably, Mary S; Zhang, Yang; Longo, Walter L

    2013-12-01

    Patients undergoing allogeneic hematopoietic stem cell transplant are at a high risk for infection-related mortality in the immediate post-transplantation phase. Prophylaxis with a fluoroquinolone is now recommended to reduce this risk with the stipulation that surveillance for increased fluoroquinolone resistance Clostridium difficile associated diarrhea be conducted. We conducted a retrospective chart review of 48 patients who underwent an allogeneic hematopoietic stem cell transplant and received a fluoroquinolone for prophylaxis and 48 patients who underwent an allogeneic hematopoietic stem cell transplant who did not receive a fluoroquinolone for prophylaxis. All patients received the same standard antifungal, antiviral and anti-pneumocystis prophylaxis. Patients receiving fluoroquinolone prophylaxis had a lower incidence of febrile neutropenia than those not receiving prophylaxis, though the difference was not found to be statistically significant (83% vs. 67%, p = 0.098). Similar non-significant improvements in the number of positive cultures recovered during an episode of febrile neutropenia and antimicrobial days were noted. No significant increase in fluoroquinolone resistance, Clostridium difficile associated diarrhea, or in methicillin resistant Staphylococcus aureus infections were noted. Our single institution experience with fluoroquinolone prophylaxis for allogeneic hematopoietic stem cell transplant patients supports continuation of this practice. Expansion to autologous hematopoietic stem cell transplant patients may be appropriate based on guideline recommendations and our institution-specific experience with fluoroquinolone prophylaxis.

  19. Differences between the different conditioning regimens for allogeneic stem cell transplantation.

    NARCIS (Netherlands)

    Schattenberg, A.V.M.B.; Levenga, T.H.

    2006-01-01

    PURPOSE OF REVIEW: The aim of this article is to compare the differences in efficacy and toxicity between the various conditioning regimens for allogeneic stem cell transplantation. RECENT FINDINGS: Several studies, all retrospective, that compare the impact of various different conditioning

  20. Titanium implant insertion into dog alveolar ridges augmented by allogenic material

    DEFF Research Database (Denmark)

    Pinholt, E M; Haanaes, H R; Donath, K

    1994-01-01

    The purpose of this investigation was to evaluate whether titanium endosseous implants would osseointegrate in dog alveolar ridges augmented by allogenic material. In 8 dogs en bloc resection, including 2 pre-molars, was performed bilaterally in the maxilla and the mandible. After a healing perio...