WorldWideScience

Sample records for allogenic anterior lens

  1. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  2. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

  3. Intracapsular lens extraction for the treatment of pupillary block glaucoma associated with anterior subluxation of the crystalline lens.

    Science.gov (United States)

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  4. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  5. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    Science.gov (United States)

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  6. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    Science.gov (United States)

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  7. Effects of lens extirpation with anterior vitrectomy on vitreous three-dimensional mesh structure

    Directory of Open Access Journals (Sweden)

    Yan Zhao

    2017-06-01

    Full Text Available AIM: To investigate the changes in vitreous gel structure after lens extirpation combined with anterior vitrectomy in rabbit eyes. METHODS: Twenty-eight chinchilla rabbits were divided into three groups. The control group (Group I included 16 eyes from eight rabbits who did not receive any treatment. Group II included 20 eyes from 10 rabbits that underwent lens aspiration only. Group III included 20 eyes from 10 rabbits that underwent lens aspiration combined with posterior capsulotomy and anterior vitrectomy. Eyes were harvested on the 30th and 60th day postoperatively, respectively. Changes in vitreous gel stretch length due to gravity and the rate of vitreous liquefaction were observed. The collagen content in the vitreous body was examined using the L-hydroxyproline test. Electronic microscopic images were obtained from each eyeball. RESULTS: On both the 30th and 60th day postoperatively, the vitreous gel length of group III was significantly shorter than group I and group II (P<0.05, while the rate of liquefaction of the vitreous body in group III was significantly higher than group I and group II (P<0.05. The collagen content in group III was also higher than that in group I and group II (P<0.05. CONCLUSION: Loss of vitreous gel mass is more likely to occur in the eyes of rabbits receiving anterior vitrectomy. Lensectomy combined with anterior vitrectomy may damage the stable three-dimensional mesh structure of collagen, which could aggravate vitreous gel liquefaction.

  8. Allogeneic versus autologous derived cell sources for use in engineered bone-ligament-bone grafts in sheep anterior cruciate ligament repair.

    Science.gov (United States)

    Mahalingam, Vasudevan D; Behbahani-Nejad, Nilofar; Horine, Storm V; Olsen, Tyler J; Smietana, Michael J; Wojtys, Edward M; Wellik, Deneen M; Arruda, Ellen M; Larkin, Lisa M

    2015-03-01

    The use of autografts versus allografts for anterior cruciate ligament (ACL) reconstruction is controversial. The current popular options for ACL reconstruction are patellar tendon or hamstring autografts, yet advances in allograft technologies have made allogeneic grafts a favorable option for repair tissue. Despite this, the mismatched biomechanical properties and risk of osteoarthritis resulting from the current graft technologies have prompted the investigation of new tissue sources for ACL reconstruction. Previous work by our lab has demonstrated that tissue-engineered bone-ligament-bone (BLB) constructs generated from an allogeneic cell source develop structural and functional properties similar to those of native ACL and vascular and neural structures that exceed those of autologous patellar tendon grafts. In this study, we investigated the effectiveness of our tissue-engineered ligament constructs fabricated from autologous versus allogeneic cell sources. Our preliminary results demonstrate that 6 months postimplantation, our tissue-engineered auto- and allogeneic BLB grafts show similar histological and mechanical outcomes indicating that the autologous grafts are a viable option for ACL reconstruction. These data indicate that our tissue-engineered autologous ligament graft could be used in clinical situations where immune rejection and disease transmission may preclude allograft use.

  9. Anterior segment and retinal OCT imaging with simplified sample arm using focus tunable lens technology (Conference Presentation)

    Science.gov (United States)

    Grulkowski, Ireneusz; Karnowski, Karol; Ruminski, Daniel; Wojtkowski, Maciej

    2016-03-01

    Availability of the long-depth-range OCT systems enables comprehensive structural imaging of the eye and extraction of biometric parameters characterizing the entire eye. Several approaches have been developed to perform OCT imaging with extended depth ranges. In particular, current SS-OCT technology seems to be suited to visualize both anterior and posterior eye in a single measurement. The aim of this study is to demonstrate integrated anterior segment and retinal SS-OCT imaging using a single instrument, in which the sample arm is equipped with the electrically tunable lens (ETL). ETL is composed of the optical liquid confined in the space by an elastic polymer membrane. The shape of the membrane, electrically controlled by a specific ring, defines the radius of curvature of the lens surface, thus it regulates the power of the lens. ETL can be also equipped with additional offset lens to adjust the tuning range of the optical power. We characterize the operation of the tunable lens using wavefront sensing. We develop the optimized optical set-up with two adaptive operational states of the ETL in order to focus the light either on the retina or on the anterior segment of the eye. We test the performance of the set-up by utilizing whole eye phantom as the object. Finally, we perform human eye in vivo imaging using the SS-OCT instrument with versatile imaging functionality that accounts for the optics of the eye and enables dynamic control of the optical beam focus.

  10. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    Science.gov (United States)

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P lens position (r = 0.371, P lens thickness (r = -0.262, P lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P lens position less than 5.1 mm had greatly reduced vaults (P lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  11. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography

    Directory of Open Access Journals (Sweden)

    Nikoo Hamzeh

    2015-12-01

    Full Text Available AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT in comparison with A-scan ultrasonography (A-scan US. METHODS: There were 218 adult subjects (218 eyes aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III. Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA. The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74. Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001, and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001 CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.

  12. Four-year Follow-up of the Changes in Anterior Segment After Phakic Collamer Lens Implantation.

    Science.gov (United States)

    Lu, Yuanyuan; Yang, Na; Li, Xuedong; Kong, Jun

    2017-06-01

    To assess the changes and relationship in central vaulting, flare intensity, and crystalline lens thickness during a follow-up period of 4 years after implantable collamer lens (ICL) implantation in eyes with high myopia. Retrospective observational study. Ninety-eight eyes of 50 patients were followed up with routine measurements of central vaulting, crystalline lens thickness, endothelial cell density, and aqueous flare postoperatively. Data were analyzed by repeated-measures analysis of variance. The relationship between the annual change in crystal lens thickness after surgery and age was evaluated by Pearson correlation coefficient and linear regression. There was a continuous reduction in central vaulting and endothelial cell density as well as an increase in crystalline lens thickness in ICL eyes from 1 month onward to 5 years postoperatively (P lens thickness (r = 0.617, P lens thickness are more prominent during the first year after ICL implantation, tending to be relatively stable afterwards. The anterior inflammation during the early postoperative period synchronizes with the sharp progression of crystalline lens changes within the first year. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Unilateral congenital corneal keloid with anterior segment mesenchymal dysgenesis and subluxated lens: case report and review of literature.

    Science.gov (United States)

    Vanathi, M; Sen, Seema; Panda, Anita; Dada, Tanuj; Behera, Geeta; Khokhar, Sudharshan

    2007-01-01

    To report the unusual association of unilateral congenital corneal keloid with anterior-segment mesenchymal dysgenesis and bilateral subluxated lens. A 20-year old man presented with a mass lesion involving the left cornea. The corneal lesion had been present since birth. On biomicroscopic examination, a well-defined vascularized, grayish-white mass occupying the whole of the left cornea was seen. The right eye showed multiple peripheral corneal opacities with iridocorneal adhesions, a poorly defined supranasal limbus, and a subluxated lens. Excision biopsy of the mass was done for histopathologic examination. Histopathologic examination of the excised corneal mass showed features consistent with that of a corneal keloid: thickened keratinized epithelium, absent Bowman membrane layer, and fibrovascular hyperplasia composed of hyalinized collagen fibers with irregular orientation of the collagen lamellae. During penetrating keratoplasty of the left eye, an anomalous iris pattern with poorly defined angle and a supranasal subluxated lens was also observed. Extraction of the subluxated lens was also done. The graft failed subsequent to a nonhealing persistent epithelial defect. Our case report highlights the rare association of a unilateral congenital corneal keloid with anterior-segment mesenchymal dysgenesis and bilateral subluxated lens.

  14. Treatment Approach to Small Inadvertent Injury of the Crystalline Lens Anterior Capsule During Iridodialysis Repair Surgery

    Directory of Open Access Journals (Sweden)

    Gökçen Gökçe

    2013-01-01

    Full Text Available A 22-year-old man presented to our ophthalmology department with photophobia. On ophthalmic examination, iridodialysis secondary to blunt trauma that occurred 5 years ago was diagnosed. During iridodialysis repair surgery, long curved double-armed needle of 10-0 polypropylene suture (PC-9 inserted into the 19 gauge side port turned down inadvertently by its own weight, resulting in crystalline lens anterior capsule perforation. Postoperative clinical observation revealed no lens opacification affecting visual acuity. This case report showed that lens aspiration surgery should be postponed if the capsule injury is small.(Turk J Ophthalmol 2013; 43: 61-3

  15. Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction.

    Science.gov (United States)

    Kramer, Gregory D; Werner, Liliana; Neuhann, Tobias; Tetz, Manfred; Mamalis, Nick

    2015-09-01

    We describe the case of a patient who had cataract surgery with implantation of the hydrophilic acrylic Tetraflex accommodating intraocular lens (IOL), with subsequent development of capsulorhexis phimosis and in-the-bag IOL subluxation. Contraction of the capsular bag secondary to fibrosis resulted in significant anterior flexing of the lens haptic component. Explantation of the IOL-capsular bag complex was required 7 years after implantation. Histopathologic analysis demonstrated multiple areas of thick anterior subcapsular fibrosis. Pseudoexfoliative material was present throughout the surface of the lens capsule. Intraocular lenses manufactured from hydrophilic acrylic material are highly flexible and may be more susceptible to capsule contraction, even in the absence of predisposing ocular and systemic conditions. This case highlights the importance of developing guidelines regarding patient screening and selection for the appropriate use of accommodating and other highly flexible IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. [Slit lamp optical coherence tomography study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation].

    Science.gov (United States)

    Yan, Pi-song; Zhang, Zhen-ping; Lin, Hao-tian; Wu, Wen-jie; Bai, Ling

    2009-09-01

    To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery (CCT increased 99.59 microm, ICT increased 234.57 microm; P = 0.490). At 1 month, the CCT almost had returned to baseline, but the ICT had been thicker about 19.25 microm than baseline(P = 0.001). The measurements of ACD, AOD500, AOD750, TISA500, TISA750 also increased significantly 1 day after surgery. Although the ACD had no changes within 2 weeks (all P 0.05). The SL-OCT could impersonality and quantificationally evaluate the anterior segment changes induced by cataract surgery.

  17. [Magnetic resonance imaging study of effects of accommodation on human lens morphological characters].

    Science.gov (United States)

    Zheng, Sui-lian; Zhang, Ai; Shi, Jian-jing; Zhou, Yun-xin

    2013-11-05

    To evaluate the effects of accommodation on lens morphological characters. From January 2011 to June 2011, magnetic resonance images of eyes were acquired from 30 subjects aged 20 to 24 years during accommodation and at rest. The optimal images were analyzed by Autocad 2010 to obtain the total lens cross-sectional area (CSA) and CSA of anterior and posterior portions of lens, anterior chamber depth, lens thickness, lens diameter, vitreous chamber depth and axial length during accommodation and at rest. Paired-t test was performed. The anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (8.7 ± 0.8), (6.2 ± 0.5), (7.5 ± 2.1), (12.0 ± 2.6), (20 ± 4) during relaxed accommodation; anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (7.1 ± 1.3), (5.6 ± 0.5), (14.7 ± 2.9), (12.2 ± 2.1) and (27 ± 4) during accommodation. The total lens CSA (t = -11.556, P 0.05) under a statistically independent accommodative state. There was significant difference in the anterior chamber depth (t = 4.366, P 0.05) and axial length (t = 0.418, P > 0.05) under accommodative states. During accommodation, the anterior chamber depth decreases, lens thickness increases and diameter of lens decreases while anterior portions and total lens CSA increase. There are insignificant changes in posterior portions of lens CSA, vitreous chamber depth and axial length. The accommodative changes in CSA indicate that the anterior portion of lens may be related with the properties of anterior capsule and lens material, the position of zonular attachments and the location of fetal nucleus. Helmholtz theory is supported.

  18. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  19. Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma

    Directory of Open Access Journals (Sweden)

    Seung Hoon Oh

    2012-01-01

    Full Text Available A 64-year-old man complained of difficulty with far vision in the right eye after blunt trauma by his hand during sleep. He had undergone uneventful phacoemulsification and intraocular lens (IOL implantation of both eyes one week before the event. On slit lamp examination, the anterior chamber was shallow compared to postoperative one day or the left eye. After mydriasis, IOL position was perfect, within the capsulorrhexis margin, and no haptics were protruded. SE of his right eye was −4.00 diopter after trauma, although spherical equivalent (SE of both eyes was near emmetropia one day after cataract surgery. We decided on IOL reposition or exchange. Intraoperatively, we pushed the IOL posteriorly; the IOL was vaulted posteriorly, as expected. After surgery, his SE was +0.25 with the same diopter IOL. We report the case on the possibility of 4-point haptic IOL vaulting anteriorly by blunt trauma within the capsular bag.

  20. Novel method of assessing delamination of the anterior lens capsule using spectral-domain optical coherence tomography

    OpenAIRE

    Tan, Deborah KL; Aung, Tin; Perera, Shamira A

    2012-01-01

    Deborah KL Tan,1 Tin Aung,1–3 Shamira A Perera1,21Singapore National Eye Centre, Singapore; 2Singapore Eye Research Institute, Singapore; 3National University of Singapore, Yong Loo Lin School of Medicine, SingaporeBackground: Delamination of the anterior lens capsule producing a double-ring sign during continuous curvilinear capsulorhexis is commonly associated with true exfoliation syndrome.Methods: Previous studies have concentrated on light- and transmission-electron microscopic...

  1. Non-invasive measurements of the dynamic changes in the ciliary muscle, crystalline lens morphology, and anterior chamber during accommodation with a high-resolution OCT.

    Science.gov (United States)

    Esteve-Taboada, José J; Domínguez-Vicent, Alberto; Monsálvez-Romín, Daniel; Del Águila-Carrasco, Antonio J; Montés-Micó, Robert

    2017-07-01

    The purpose of the study was to assess non-invasively the changes in the anterior chamber eye, crystalline lens morphology, and ciliary muscle during accommodation by means of an anterior chamber optical coherence tomographer (OCT), and correlate them with vergence. Twenty-five eyes of twenty-five healthy subjects, whose mean age was 29.9±7.1 years, were included and measured with an anterior chamber OCT. The central corneal thickness (CCT), anterior chamber depth (ACD), anterior crystalline lens radius of curvature (ALRC), crystalline lens thickness (CLT), and ciliary muscle area (CMA) were measured for each participant at 0, -1, -2, and -3 D of target vergence. A linear model was used to assess the correlation of each eye parameter with the vergence demand. The mean CCT showed no change for all the accommodative stimuli. The mean ACD and ALRC decreased with the vergence, about 4.5 and 30 % at -3 D, respectively. On the contrary, the CLT and CMA showed an opposite tendency, where the mean CLT was increased by 4.0 % and the mean CMA was done by 26% at -3 D. Statistical significant differences (p < 0.001) were obtained among all vergences for each eye metric, except for the CCT (p = 0.76). The ACD and ALRC decreased about 2 and 10 % per dioptre of accommodation, respectively; whereas the CLT and CMA increased about 2 and 9 %, respectively. These results add knowledge regarding the understanding of accommodation and give new perspectives for biomechanics and biometry.

  2. [Visual rehabilitation of patients with large post-traumatic defects of the anterior eye segment through iris-lens diaphragm implantation].

    Science.gov (United States)

    Khodzhaev, N S; Sobolev, N P; Mushkova, I A; Izmaylova, S B; Karimova, A N

    The diversity of methodological approaches and lack of pathogenetically reasonable tactics for patients with combined ocular injuries became the basis for the development and systematization of surgical rehabilitation stages of patients, in whom post-traumatic cataract is combined with post-traumatic aniridia and corneal scarring. to construct a visual rehabilitation approach to patients with post-traumatic defects of the anterior eye segment following optical-reconstructive surgery that involved implantation of an iris-lens diaphragm (ILD). We have analyzed 80 reconstructive cases with ILD implantation in patients with post-traumatic aniridia and corneal damage. These patients constituted the first study group (Group 1). We have also investigated 58 eyes with residual ametropy and stable visual function 1 year after ILD implantation before and after conducting a laser keratorefractive surgery. These patients were assigned to the second study group (Group 2). Rehabilitation approach to patients after anterior segment injuries that has been proposed allows to achieve high clinical and functional results and reduce the risk of intra- and postoperative complications. The proposed approach to patients after optical-reconstructive surgery with iris-lens diaphragm implantation followed by keratorefractive surgery is an effective method of visual rehabilitation of anterior eye segment post-traumatic defects.

  3. Optical Coherence Tomography Examination of the Anterior Segment in a Case of Corneal Perforation and Lens Trauma by Chestnut Burr

    Directory of Open Access Journals (Sweden)

    Takashi Ono

    2018-02-01

    Full Text Available Chestnut burrs, the thorny encapsulation of chestnut fruit, can sometimes cause corneal injuries and ulceration, with poor prognoses. We report a case of corneal perforation and damaged anterior lens capsule due to a chestnut burr, using anterior segment optical coherence tomography (AS-OCT. A 67-year-old woman with a chestnut burr injury in her right eye was referred to our hospital. Her right best-corrected visual acuity (BCVA was 0.8. Slit-lamp examination and AS-OCT showed perforation involving the endothelial layer at the center of the cornea. The iris and anterior lens capsule were damaged. Cell infiltration was observed around the wound. Bacterial examination showed gram-positive cocci but no fungi. The patient was diagnosed with a corneal perforation and bacterial keratitis. Levofloxacin 1.5% and cefmenoxime treatments were initiated and a soft contact lens was placed to seal the wound. On day 3, there was no improvement in the corneal cell infiltration, but AS-OCT suggested that the inner wound had closed. A culture test revealed the presence of Propionibacterium acnes, which was sensitive to both levofloxacin and cefmenoxime. Therefore, we continued the same antibiotic treatment. On day 26, the opacification and cell infiltration at the center of the cornea had improved. AS-OCT showed healing of the corneal wound with reduction in the central corneal thickness. Her BCVA improved to 1.0. AS-OCT was a valuable tool to noninvasively observe wound shape and detect the presence of any intracorneal foreign bodies.

  4. Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film.

    Science.gov (United States)

    Sonier, Marcus; Wronski, Matt; Yeboah, Collins

    2015-03-08

    Lens dose is a concern during the treatment of facial lesions with anterior electron beams. Lead shielding is routinely employed to reduce lens dose and minimize late complications. The purpose of this work is twofold: 1) to measure dose pro-files under large-area lead shielding at the lens depth for clinical electron energies via film dosimetry; and 2) to assess the accuracy of the Pinnacle treatment planning system in calculating doses under lead shields. First, to simulate the clinical geometry, EBT3 film and 4 cm wide lead shields were incorporated into a Solid Water phantom. With the lead shield inside the phantom, the film was positioned at a depth of 0.7 cm below the lead, while a variable thickness of solid water, simulating bolus, was placed on top. This geometry was reproduced in Pinnacle to calculate dose profiles using the pencil beam electron algorithm. The measured and calculated dose profiles were normalized to the central-axis dose maximum in a homogeneous phantom with no lead shielding. The resulting measured profiles, functions of bolus thickness and incident electron energy, can be used to estimate the lens dose under various clinical scenarios. These profiles showed a minimum lead margin of 0.5 cm beyond the lens boundary is required to shield the lens to ≤ 10% of the dose maximum. Comparisons with Pinnacle showed a consistent overestimation of dose under the lead shield with discrepancies of ~ 25% occur-ring near the shield edge. This discrepancy was found to increase with electron energy and bolus thickness and decrease with distance from the lead edge. Thus, the Pinnacle electron algorithm is not recommended for estimating lens dose in this situation. The film measurements, however, allow for a reasonable estimate of lens dose from electron beams and for clinicians to assess the lead margin required to reduce the lens dose to an acceptable level.

  5. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. A Model of the Effect of Lens Development on Refraction in Schoolchildren.

    Science.gov (United States)

    He, Ji C

    2017-12-01

    The study provides a new theory on the mechanism underlying myopia development, and it could be useful in clinical practice to control myopia development in schoolchildren. To model the effect of the crystalline lens on refractive development in schoolchildren. The Zemax 13 was used to calculate Zernike aberrations and refractions across 50° horizontal visual fields. Optical effects of the anterior chamber depth, lens thickness, and radii of curvature of the lens surfaces on refractions were modeled. Refractive changes induced by lens development in emmetropic and myopic eyes, based on a previous longitudinal study from literature, were calculated. A lens thickness reduction with an anterior chamber depth deepening caused a hyperopic shift over the visual fields and even more at the periphery. Opposite effects were found when the lens was thinned without any change of the anterior chamber depth. While a flattening of the anterior lens surface produced hyperopic refractions overall, a posterior lens flattening caused a myopic shift at the periphery, but a hyperopic shift of the central refraction. In the myopic eye, lens development induced refractive change toward more hyperopic over the visual fields and more at the periphery. Lens thinning and lens axial movement participate in peripheral refractive development in schoolchildren, and lens development with a deeper anterior chamber depth and a flatter lens surface in the myopic eye could generate extra hyperopia over visual fields. The myopic lens development could be due to a backward movement of the lens, driven by a backward growth of the ciliary process, which might be a causative factor of myopia development.

  7. Anterior capsulotomy using the CO2 laser

    Science.gov (United States)

    Barak, Adiel; Ma-Naim, Tova; Rosner, Mordechai; Eyal, Ophir; Belkin, Michael

    1998-06-01

    Continuous circular capsulorhexis (CCC) is the preferred technique for removal of the anterior capsule during cataract surgery due to this technique assuring accurate centration of the intraocular lens. During modern cataract surgery, especially with small or foldable intra ocular lenses, centration of the lens is obligatory. Radial tears at the margin of an anterior capsulotomy may be associated with the exit of at least one loop of an intraocular lens out of the capsular bag ('pea pod' effect) and its subsequent decentration. The anterior capsule is more likely to ream intact if the continuous circular capsulorhexis (CCC) technique is used. Although manual capsulorhexis is an ideal anterior capsulectomy technique for adults, many ophthalmologists are still uncomfortable with it and find it difficult to perform, especially in complicated cases such as these done behind small pupil, cataract extraction in children and pseudoexfoliation syndrome. We have developed a technique using a CO2 laser system for safe anterior capsulotomy and tested it in animal eyes.

  8. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    Science.gov (United States)

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  9. Anterior capsular rupture following blunt ocular injury

    Science.gov (United States)

    Gremida, Anas; Kassem, Iris; Traish, Aisha

    2011-01-01

    Summary A 10-year-old boy suffered a large, oblique anterior capsular tear following blunt injury to his right eye. The boy was followed daily for hyphema resolution and progressive traumatic cataract formation. After the hyphema had resolved, the lens was removed using an anterior approach and an intraocular lens was placed with excellent visual outcome. PMID:23362402

  10. Horizontal ridge reconstruction of the anterior maxilla using customized allogeneic bone blocks with a minimally invasive technique - a case series.

    Science.gov (United States)

    Venet, Laurent; Perriat, Michel; Mangano, Francesco Guido; Fortin, Thomas

    2017-12-08

    Different surgical procedures have been proposed to achieve horizontal ridge reconstruction of the anterior maxilla; all these procedures, however, require bone replacement materials to be adapted to the bone defect at the time of implantation, resulting in complex and time-consuming procedures. The purpose of this study was to describe how to use a 3D printed hardcopy model of the maxilla to prepare customized milled bone blocks, to be adapted on the bone defect areas using a minimally invasive subperiosteal tunneling technique. Cone beam computed tomography (CBCT) images of the atrophic maxilla of six patients were acquired and modified into 3D reconstruction models. Data were transferred to a 3D printer and solid models were fabricated using autoclavable nylon polyamide. Before the surgery, freeze-dried cortico-cancellous blocks were manually milled and adapted on the 3D printed hardcopy models of the maxillary bone, in order to obtain customized allogeneic bone blocks. In total, eleven onlay customized allogeneic bone grafts were prepared and implanted in 6 patients, using a minimally invasive subperiosteal tunneling technique. The scaffolds closely matched the shape of the defects: this reduced the operation time and contributed to good healing. The patients did not demonstrate adverse events such as inflammation, dehiscence or flap re-opening during the recovery period; however, one patient experienced scaffold resorption, which was likely caused by uncontrolled motion of the removable provisional prosthesis. Following a 6 month healing period, CBCT was used to assess graft integration, which was followed by insertion of implants into the augmented areas. Prosthetic restorations were placed 4 months later. These observations suggest that customized bone allografts can be successfully used for horizontal ridge reconstruction of the anterior maxilla: patients demonstrated reduced morbidity and decreased total surgery time. Further studies on a larger sample

  11. Long anterior zonules and pigment dispersion.

    Science.gov (United States)

    Moroi, Sayoko E; Lark, Kurt K; Sieving, Paul A; Nouri-Mahdavi, Kouros; Schlötzer-Schrehardt, Ursula; Katz, Gregory J; Ritch, Robert

    2003-12-01

    To describe pigment dispersion associated with long anterior zonules. Multicenter observational case series. Fifteen patients, seven of whom were treated for glaucoma or ocular hypertension, were identified with long anterior zonules and pigment dispersion. Transmission electron microscopy was performed on one anterior capsule specimen. All patients had anterior zonules that inserted centrally on the lens capsule. Signs of pigment dispersion included corneal endothelial pigmentation, loss of the pupillary ruff, and variable trabecular meshwork pigmentation. Ultrasound biomicroscopy verified the lack of posterior iris insertion and concavity. There was no exfoliation material. Transmission electron microscopy showed zonular lamellae with adherent pigment granules, and no exfoliation material. Long anterior zonules inserted onto the central lens capsule may cause mechanical disruption of the pigment epithelium at the pupillary ruff and central iris leading to pigment dispersion.

  12. Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps.

    Science.gov (United States)

    Huang, Yan-Ming; Yan, Hua; Cai, Jin-Hong; Li, Hai-Bo

    2017-01-01

    To introduce a novel approach in removal of anterior chamber angle foreign body (ACFB) using a prism contact lens and 23-gauge foreign body forceps. Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. The success rate of ACFB once removal was 75% (15/20) in group A, and 100% (22/22) in group B. The average operation time of group A was significantly longer compared with group B (34.9±9.88min vs 22.13±8.85min; P contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach.

  13. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  14. ASSESSMENT OF LENS THICKNESS IN ANGLE CLOSURE DISEASE

    Directory of Open Access Journals (Sweden)

    Nishat Sultana Khayoom

    2016-08-01

    Full Text Available BACKGROUND Anterior chamber depth and lens thickness have been considered as important biometric determinants in primary angle-closure glaucoma. Patients with primary narrow angle may be classified as a primary angle closure suspect (PACS, or as having primary angle closure (PAC or primary angle closure glaucoma (PACG. 23.9% of patients with primary angle closure disease are in India, which highlights the importance of understanding the disease, its natural history, and its underlying pathophysiology, so that we may try to establish effective methods of treatment and preventative measures to delay, or even arrest, disease progression, thereby reducing visual morbidity. AIM To determine the lens thickness using A-scan biometry and its significance in various stages of angle closure disease. MATERIALS AND METHODS Patients attending outpatient department at Minto Ophthalmic Hospital between October 2013 to May 2015 were screened for angle closure disease and subsequently evaluated at glaucoma department. In our study, lens thickness showed a direct correlation with shallowing of the anterior chamber by determining the LT/ ACD ratio. A decrease in anterior chamber depth is proportional to the narrowing of the angle which contributes to the progression of the angle closure disease from just apposition to occlusion enhancing the risk for optic nerve damage and visual field loss. Hence, if the lens thickness values are assessed earlier in the disease process, appropriate intervention can be planned. CONCLUSION Determination of lens changes along with anterior chamber depth and axial length morphometrically can aid in early detection of angle closure. The role of lens extraction for PACG is a subject of increased interest. Lens extraction promotes the benefits of anatomical opening of the angle, IOP reduction and improved vision. This potential intervention may be one among the armamentarium of approaches for PACG. Among the current treatment modalities

  15. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    Science.gov (United States)

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  16. Surgical effect of traumatic lens dislocation with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Dan Zhang

    2014-10-01

    Full Text Available AIM: To retrospectively evaluate the effect of lens extraction combined with vitrectomy to treat traumatic lens dislocation with secondary glaucoma.METHODS:Thirty-one eyes(31 casesof lens dislocation caused by blunt trauma with secondary glaucoma were treated respectively with cataract extraction combined with anterior vitrectomy, trabeculectomy and intraocular lens implantation. The visual acuity and pressure were observed 1wk, 1 and 3mo after operative. RESULTS:Thirty-one eyes were all complete the operation successfully, and 6 eyes were given combined trabeculectomy, 9 eyes were implanted anterior chamber intraocular lens implantation(IOLand 15 eyes were given posterior chamber suture fixation. Sixteen eyes were implanted in one-stage operation, while 8 eyes were implanted in two-stage operation. All intraocular pressure(IOPwere controlled to the normal level after operation and 23 eyes had visual acuity of more than 0.3.CONCLUSION:Lens extraction combined with vitrectomy is an effective method for treatment of lens dislocation with secondary glaucoma. In order to control the IOP and get well visual function, we should choose IOL implantation or trabeculectomy according to the patient's condition.

  17. Ultrastructural effects of silicone oil on the clear crystalline lens of the human eye.

    Science.gov (United States)

    Soliman, Wael; Sharaf, Mohamed; Abdelazeem, Khaled; El-Gamal, Dalia; Nafady, Allam

    2018-03-01

    To evaluate light and electron microscopic changes of the anterior capsule and its epithelium after clear lens extraction of vitrectomized myopic eyes with silicone oil tamponade. This prospective, controlled, non-randomized, interventional study included 20 anterior lens capsular specimens that were excised during combined clear lens extraction and silicone oil removal from previously vitrectomized highly myopic patients with silicone oil tamponade for previous retinal detachment surgeries. The specimens were examined via light microscopy and electron microscopy and compared with 20 anterior capsule specimens removed during clear lens extraction of non-vitrectomized highly myopic eyes. Light microscopic examination of clear lens anterior capsule specimens of vitrectomized myopic eyes filled with silicone oil showed relatively more flat cells with irregular outline of lens' epithelial cells with wide intercellular spaces, deeply stained nuclei, and multiple intracytoplasmic vacuoles. Scanning electron microscopy revealed collagenous surfaces filled with multiple pits, depressions, and abnormal deposits. Transmission electron microscopy revealed lens epithelial cells with apoptotic changes, many cytoplasmic vacuoles, and filopodia-like protrusions between lens epithelial cells and the capsule. Epithelial proliferation and multilayering were also observed. silicone oil may play a role in the development of apoptotic and histopathological changes in clear lens epithelial cells. Clarity of the lens at the time of silicone oil removal does not indicate an absence of cataractous changes. We found justification of combined clear lens extraction and silicone oil removal or combined phacovitrectomy when silicone oil injection is planned, but further long-term studies with larger patient groups are required.

  18. Treatment of a dislocated lens by transcorneal vitrectomy and bimanual phacoemulsification

    Directory of Open Access Journals (Sweden)

    Watanabe A

    2014-08-01

    Full Text Available Akira Watanabe, Tamaki Gekka, Hiroshi Tsuneoka Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan Background: As a method of treatment for a dropped lens nucleus, which occurred during cataract surgery, the dropped lens nucleus was removed through the corneal wound without using pars plana vitrectomy (PPV. After vitrectomy, the dropped lens nucleus was floated on the perfluorocarbon liquid (PFCL. The floating lens nucleus was then phacoemulsified and aspirated. During surgery, irrigation from the anterior chamber was performed. This method was very effective for treatment of a dropped hard nucleus.Case report: During cataract surgery on the left eye of an 80-year-old woman, a posterior capsule rupture occurred. As a result, the lens nucleus dropped into the vitreous cavity. Irrigation to the anterior chamber was performed, with an anterior chamber maintainer inserted through a newly created side port at the corneal limbus. A vitreous cutter and a light guide were inserted in order to perform vitrectomy through the corneal incisions that were created for the cataract surgery. After vitrectomy, the dropped lens nucleus was floated using PFCL. The floating lens nucleus was removed by a bimanual phacoemulsification technique, with the anterior chamber irrigation continuing. The separation of the irrigation port and the aspiration port allowed for effective treatment of the dropped nucleus that was floating on the PFCL, even using a ­phacoemulsification machine with a peristaltic pump system. Safe and effective vitrectomy, similar to a PPV, could be performed with this method using three corneal ports.Conclusion: This technique may allow safer and more effective treatment for a dropped lens nucleus compared with conventional PPV. With this technique, corneal distortion due to surgical manipulation can lead to reduced visibility of the posterior eye. Keywords: dislocated lens, transcorneal vitrectomy, bimanual

  19. The lens and cataracts.

    Science.gov (United States)

    Matthews, Andrew G

    2004-08-01

    It is conservatively estimated that some form of lens opacity is present in 5% to 7% of horses with otherwise clinically normal eyes.These opacities can range from small epicapsular remnants of the fetal vasculature to dense and extensive cataract. A cataract is defined technically as any opacity or alteration in the optical homogeneity of the lens involving one or more of the following: anterior epithelium, capsule, cortex, or nucleus. In the horse, cataracts rarely involve the entire lens structure (ie, complete cataracts) and are more usually localized to one anatomic landmark or sector of the lens. Complete cataracts are invariably associated with overt and significant visual disability. Focal or incomplete cataracts alone seldom cause any apparent visual dysfunction in affected horses,however.

  20. SU-E-T-556: Monte Carlo Generated Dose Distributions for Orbital Irradiation Using a Single Anterior-Posterior Electron Beam and a Hanging Lens Shield

    International Nuclear Information System (INIS)

    Duwel, D; Lamba, M; Elson, H; Kumar, N

    2015-01-01

    Purpose: Various cancers of the eye are successfully treated with radiotherapy utilizing one anterior-posterior (A/P) beam that encompasses the entire content of the orbit. In such cases, a hanging lens shield can be used to spare dose to the radiosensitive lens of the eye to prevent cataracts. Methods: This research focused on Monte Carlo characterization of dose distributions resulting from a single A-P field to the orbit with a hanging shield in place. Monte Carlo codes were developed which calculated dose distributions for various electron radiation energies, hanging lens shield radii, shield heights above the eye, and beam spoiler configurations. Film dosimetry was used to benchmark the coding to ensure it was calculating relative dose accurately. Results: The Monte Carlo dose calculations indicated that lateral and depth dose profiles are insensitive to changes in shield height and electron beam energy. Dose deposition was sensitive to shield radius and beam spoiler composition and height above the eye. Conclusion: The use of a single A/P electron beam to treat cancers of the eye while maintaining adequate lens sparing is feasible. Shield radius should be customized to have the same radius as the patient’s lens. A beam spoiler should be used if it is desired to substantially dose the eye tissues lying posterior to the lens in the shadow of the lens shield. The compromise between lens sparing and dose to diseased tissues surrounding the lens can be modulated by varying the beam spoiler thickness, spoiler material composition, and spoiler height above the eye. The sparing ratio is a metric that can be used to evaluate the compromise between lens sparing and dose to surrounding tissues. The higher the ratio, the more dose received by the tissues immediately posterior to the lens relative to the dose received by the lens

  1. BILATERAL SIMULTANEOUS ANTERIOR AND POSTERIOR LENTICONUS WITHOUT SYSTEMIC SIGNS

    Directory of Open Access Journals (Sweden)

    Hima Bindu

    2015-02-01

    Full Text Available A 21 year male came for eye checkup with a refractive error OD - 12.00 sph, - 2.25 @ 160° cyl and OS - 15.00 sph, - 2.50 @ 5°cyl and was referred to department of refractive surgery for opinion His BCVA in OD 6 / 18, OS 6/ 24. Slit lamp examination under dilation with phenylephrine plus tropic amide revealed the abnormal contour of the anterior and posterior lens capsule. Rest of the findings were normal with clear cornea, Von Herricks grade 3 deep anterior chamber, open angles in Gonioscopy. Retro illumination showed the typical’ oil droplet configuration’ in the lens. Retinal examination with the 90 D lens was otherwise normal except of the peculiar ‘OMEGA' shaped curving of the slit beam over the retina which occurred due the difference in the refractive power of the lens in the axial and paraxial zones of the lens

  2. Spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium

    Directory of Open Access Journals (Sweden)

    Toshiaki Mochizuki

    2014-09-01

    Full Text Available Cell proliferation is a key regulator of tissue morphogenesis. We examined cell proliferation and cell division in zebrafish lens epithelium by visualizing cell-cycle phases and nuclear positions, using fluorescent-labeled geminin and histone proteins. Proliferation was low in the anterior region of lens epithelium and higher in the marginal zone anterior to the equator, suggesting that the proliferation zone, called the germinative zone, is formed in zebrafish lens. Interestingly, cell-division orientation was biased longitudinally in the anterior region, shifted from longitudinal to circumferential along the anterior–posterior axis of lens sphere, and was biased circumferentially in the peripheral region. These data suggest that cell-division orientation is spatially regulated in zebrafish lens epithelium. The Hertwig rule indicates that cells tend to divide along their long axes. Orientation of long axes and cell division were biased similarly in zebrafish lens epithelium, suggesting that cell geometry correlates with cell-division orientation. A cell adhesion molecule, E-cadherin, is expressed in lens epithelium. In a zebrafish e-cadherin mutant, the long axes and cell-division orientation were shifted more longitudinally. These data suggest that E-cadherin is required for the spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium.

  3. Late anterior traumatic subluxation of a circular in-the-bag intraocular lens associated with lack of posterior capsule opacification.

    Science.gov (United States)

    Billotte, Christian; Stéfani, Pierre; Lecoq, Pierre

    2003-05-01

    We report a case of traumatic subluxation of a circular poly(methyl methacrylate) intraocular lens (IOL) 5 years after surgery. Slitlamp examination revealed the lack of epithelial cells or fibrosis in the intact capsule bag. Trauma was minor, and no other complication was found in the eye and orbit. The subluxated IOL was easily relocated in the bag with a hook, revealing the poor capsule sealing. Among the factors ensuring the fixation of IOLs placed in the bag after continuous curvilinear capsulotomy are sealing of the anterior and posterior capsules and proliferation of epithelial cells from the equator of the bag.

  4. Mechanism research of miR-181 regulating human lens epithelial cell apoptosis

    Directory of Open Access Journals (Sweden)

    Yu Qin

    2015-05-01

    Full Text Available AIM: To investigate the expression of miR-181 in the lens tissue of cataract and the regulating mechanism of miR-181 on apoptosis of human lens epithelial cell.METHODS:Real time q-PCR was used to measure the expression of miR-181 in the anterior lens capsules of age-related cataract and human lens epithelial cell apoptosis model. miR-181 mimic and inhibitor were transfected using Lipofectamine 2 000 to regulate the expression of miR-181, and then Real time q-PCR was used to verify transfection efficiency. Flow cytometry was used to detect the change of cell apoptosis rate. RESULTS: Compared with control group, the expression of miR-181 was significantly higher in both the anterior lens capsules of age-related cataract and human lens epithelial cell apoptosis model; the relative expression of miR-181 in lens epithelial cells transfected with miR-181 mimic was increased, whereas decreased in cells transfected with miR-181 inhibitor; the apoptosis rate of cells transfected with miR-181 mimic was increased, while reduced in miR-181 inhibitor group. Each result was statistically significant(PCONCLUSION: High expression of miR-181 is detected in anterior lens capsule of age-related cataract. miR-181 might play a certain role in the pathogenesis of cataract via promoting human lens epithelial cell apoptosis. miR-181 probably becomes a new approach for the nonoperative treatment of cataract, but the concrete mechanism still needs to be further studied.

  5. Analysis of incidence and related factors on effusion of anterior chamber after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Bing-Bing Zhao

    2018-02-01

    Full Text Available AIM: To investigate the incidence and related factors on effusion of anterior chamber(ACafter phacoemulsification(PEcombined with intraocular lens(IOLimplantation. METHODS: Totally 359 cases of cataract(375 eyesunderwent PE combined with IOL implantation were collected in our hospital. The incidence of AC exudation after operation and related factors were analyzed by single factor and multiple logistic regression analysis. RESULTS: The group was included in 359 cases(375 eyes. The incidence of postoperative AC exudation in the study group was 5.9%(22/375. The preoperative intraocular pressure(IOP, visual acuity before and after surgery, nuclear grades, posterior capsular rupture(PCRrate and ultrasonic accumulated energy complex parameter(AECPof the study group showed statistically significant difference compared with the control group(all P21mmHg, intraoperative pupil diameter 7.25(%×min, the lens nucleus grade ≥ IV were risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all P21mmHg, ultrasound AECP >7.25 were independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all PCONCLUSION: High myopia, glaucoma, uveitis, the lens nucleus grade ≥ IV, the incidence of intraoperative PCR, preoperative IOP>21mmHg, ultrasonic AECP>7.25 are independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract, with such risk factors in patients with cataract should be paid closely attention and timely diagnosis and treatment in clinic.

  6. [Are biometric parameters of anterior segment of the eyeball influenced by type 2 diabetes?].

    Science.gov (United States)

    Dmuchowska, Diana A; Kraśnicki, Paweł; Mariak, Zofia

    2012-01-01

    To answer the question whether biometric parameters of anterior segment of the eyeball are influenced by type 2 diabetes, at the stage when the lens is still transparent, so before cataract development. Fifty subjects (28 women and 22 men), at the age of 63.3 +/- 11.3 years were enrolled in this prospective study. They were divided in 2 groups: patients with type 2 diabetes (24 subjects) and analogous age group in good general health - control group (26 subjects). None of the tested individuals presented lens opacities. The planned biometric measurements included: central corneal thickness, anterior chamber depth and axial lens thickness. The data were statistically analyzed. There was no difference between the groups of both proven and potential parameters that are associated with biometric measurements of the anterior segment of the eyeball, such as: gender, age, smoking and axial length of the eye. In diabetic patients, as opposed to the subjects in the control group, statistically significantly increased lens thickness (4.78 +/- 0.50 mm vs 4.43 +/- 0.50; p = 0.016), central corneal thickness (561.5 +/- 31.6 microm vs 542.2 +/- 35.2; p = 0.047), and the tendency for shallow anterior chamber (3.06 +/- 0.40 mm vs 3.22 +/- 0.38; p = 0.159), were observed. In patients with diabetes there was no association of the biometric parameters values with the duration of diabetes and presence of diabetic retinopathy. Type 2 diabetes contributes to increased axial corneal and lens thickness at the stage when the lens is transparent, albeit it does not significantly affect anterior chamber depth.

  7. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  8. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  9. In vivo crystalline lens measurements with novel swept-source optical coherent tomography: an investigation on variability of measurement

    Science.gov (United States)

    Shoji, Takuhei; Kato, Naoko; Ishikawa, Sho; Ibuki, Hisashi; Yamada, Norihiro; Kimura, Itaru; Shinoda, Kei

    2017-01-01

    Objective To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. Methods and analysis One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), −1 D, −3 D and −5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. Results The intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects. Conclusions This novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress. PMID:29354706

  10. Development of PET Imaging to Visualize Activated Macrophages Accumulated in the Transplanted iPSc-Derived Cardiac Myocytes of Allogeneic Origin for Detecting the Immune Rejection of Allogeneic Cell Transplants in Mice.

    Directory of Open Access Journals (Sweden)

    Noriyuki Kashiyama

    Full Text Available Allogeneic transplantation (Tx of induced pluripotent stem cells (iPSCs is a promising tissue regeneration therapy. However, this inevitably induces macrophage-mediated immune response against the graft, limiting its therapeutic efficacy. Monitoring the magnitude of the immune response using imaging tools would be useful for prolonging graft survival and increasing the therapy longevity. Minimally invasive quantitative detection of activated macrophages by medical imaging technologies such as positron emission tomography (PET imaging targets translocator protein (TSPO, which is highly expressed on mitochondrial membrane, especially in activated macrophage. N,N-diethyl-2-[4-(2-fluoroethoxy phenyl]-5,7-dimethylpyrazolo[1,5-a]pyrimidine-3-acetamide (DPA-714 is known as a TSPO ligand used in clinical settings. We herein hypothesized that immune rejection of the transplanted iPSC-derived cardiomyocytes (iPSC-CMs of allogeneic origin may be quantitated using 18F-DPA-714-PET imaging study. iPSC-CM cell-sheets of C57BL/6 mice origin were transplanted on the surface of the left ventricle (LV of C57BL/6 mice as a syngeneic cell-transplant model (syngeneic Tx group, or Balb/c mice as an allogeneic model (allogeneic Tx group. 18F-DPA-714-PET was used to determine the uptake ratio, calculated as the maximum standardized uptake value in the anterior and septal wall of the LV. The uptake ratio was significantly higher in the allogeneic Tx group than in the syngeneic group or the sham group at days 7 and day 10 after the cell transplantation. In addition, the immunochemistry showed significant presence of CD68 and CD3-positive cells at day 7 and 10 in the transplanted graft of the allogeneic Tx group. The expression of TSPO, CD68, IL-1 beta, and MCP-1 was significantly higher in the allogeneic Tx group than in the syngeneic Tx and the sham groups at day 7. The 18F-DPA-714-PET imaging study enabled quantitative visualization of the macrophages-mediated immune

  11. Allogenic bone grafts in post-traumatic juxta-articular defects: Need for allogenic bone banking.

    Science.gov (United States)

    Mishra, Anil Kumar; Vikas, Rohit; Agrawal, H S

    2017-07-01

    Allogenic bone banking provide both structural and granular bone grafts for various orthopaedic, spinal, oncological and dental surgeries. However allogenic bones, presently, are not readily available. This article discusses the clinical applications of the allogenic grafts, the screening criteria and procedure for maintenance of such a bone banking facility. This article demonstrates the effective role of allogenic bone in a case of post-traumatic bone loss situation and discusses the growing need and present situation of bone banking in our country.

  12. Cataract Surgery in Anterior Megalophthalmos: A Review

    Science.gov (United States)

    GALVIS, Virgilio; TELLO, Alejandro; M. RANGEL, Carlos

    2015-01-01

    Anterior megalophthalmos is characterized by megalocornea associated with a very broad anterior chamber and ciliary ring elongation. It is also called X-linked megalocornea. It is accompanied by early development of cataracts, zonular anomalies, and, rarely, vitreoretinal disorders. Subluxation of a cataract can occur in cataract surgery because of zonular weakness. In addition, in most patients, standard intraocular lens (IOL) decentration is a risk because of the enlarged sulcus and capsular bag. These unique circumstances make cataract surgery challenging. To date, several approaches have been developed. Implantation of a retropupillary iris-claw aphakic intraocular lens may be a good option because it is easier than suturing the IOL and can have better and more stable anatomic and visual outcomes, compared to other techniques. PMID:27350950

  13. Which soft contact lens power is better for piggyback fitting in keratoconus?

    Science.gov (United States)

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose Manuel

    2013-02-01

    To evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus. Nineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of -3.00, -1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated. Negative- and plano-powered soft lenses flattened (ppowered lenses did not induce any significant changes (p>0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (psoft lens power in comparison to the naked eye (p>0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p0.05). Statistically differences were found in coma-like and secondary astigmatism (both ppowered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    Science.gov (United States)

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  15. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    Science.gov (United States)

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  16. Severe pigment dispersion after iris-claw phakic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    2017-01-01

    Full Text Available A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  17. [Pigment dispersion and Artisan implants: crystalline lens rise as a safety criterion].

    Science.gov (United States)

    Baikoff, G; Bourgeon, G; Jodai, H Jitsuo; Fontaine, A; Vieira Lellis, F; Trinquet, L

    2005-06-01

    To validate the theoretical notion of a crystalline lens rise as a safety criterion for ARTISAN implants in order to prevent the development of pigment dispersion in the implanted eye. Crystalline lens rise is defined by the distance between the crystalline lens's anterior pole and the horizontal plane joining the opposite iridocorneal recesses. We analyzed the biometric measurements of 87 eyes with an Artisan implant. A comparative analysis of the crystalline lens rise was carried out on the nine eyes having developed pigment dispersion and 78 eyes with no problems. Among the modern anterior segment imaging devices (Artemis, Scheimpflug photography, optical coherence tomography, radiology exploration, magnetic resonance imaging, TDM), an anterior chamber optical coherence tomography (AC-OCT) prototype was used. This working hypothesis was confirmed by this study: the crystalline lens rise must be considered as a new safety criterion for implanting Artisan phakic lenses. Indeed, the higher the crystalline lens's rise, the greater the risk of developing pigment dispersion in the pupil area. This complication is more frequent in hyperopes than in myopes. We can consider that there is little or no risk of pigment dispersion if the rise is below 600 microm; however, at 600 microm or greater, there is a 67% rate of pupillary pigment dispersion. In certain cases, when the implant was loosely fixed, there was no traction on the iris root. This is a complication that can be avoided or delayed. The crystalline lens rise must be part of new safety criteria to be taken into consideration when inserting an Artisan implant. This notion must also be applied to other types of phakic implants. The distance remaining between the crystalline lens rise and a 600-micromm theoretical safety level allows one to calculate a safety time interval.

  18. A medieval fallacy: the crystalline lens in the center of the eye.

    Science.gov (United States)

    Leffler, Christopher T; Hadi, Tamer M; Udupa, Akrithi; Schwartz, Stephen G; Schwartz, Daniel

    2016-01-01

    To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3-5.3 mm). Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly. There is little reason to believe that Celsus or other ancient authors held a variant understanding of the anatomy of a healthy eye. The notion of the central location of the lens seems to have arisen with Arabic authors in 9th century Mesopotamia, and lasted for over 7 centuries.

  19. Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion.

    Science.gov (United States)

    Baïkoff, Georges; Bourgeon, Grégoire; Jodai, Horacio Jitsuo; Fontaine, Aline; Lellis, Fernando Viera; Trinquet, Laure

    2005-04-01

    To validate the theory that crystalline lens rise can be used as a safety criterion to prevent pigment dispersion in eyes with an Artisan phakic intraocular lens (IOL) (Ophtec BV). Monticelli Clinic, Marseilles, France. A comparative analysis of crystalline lens rise in 9 eyes with pigment dispersion and 78 eyes without dispersion was performed. All eyes had previous implantation of an Artisan IOL. Anterior segment imaging was done using an anterior chamber optical coherence tomography (AC OCT) prototype. Crystalline lens rise was defined by the distance between the anterior pole of the crystalline lens and the horizontal plane joining the opposite iridocorneal recesses. The study confirmed that crystalline lens rise can be considered a safety criterion for implantation of Artisan-type phakic IOLs. The higher the crystalline lens rise, the greater the risk for developing pigment dispersion in the area of the pupil. This complication occurred more frequently in hyperopic eyes than in myopic eyes. Results indicate there is little or no risk for pigment dispersion if the rise is less than 600 microm; 67% of eyes with a rise of 600 microm or more developed pupillary pigment dispersion. In some cases in which the IOL was loosely fixated, there was no traction on the iris root and dispersion was prevented or delayed. Crystalline lens rise should be considered a new safety criterion for Artisan phakic IOL implantation and should also be applied to other types of phakic IOLs. The distance remaining between the crystalline lens rise and a 600 microm theoretical safety level allows one to calculate how long the IOL can safely remain in the eye.

  20. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  1. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  2. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  3. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  4. Cx43, ZO-1, alpha-catenin and beta-catenin in cataractous lens

    Indian Academy of Sciences (India)

    Specimens of the anterior lens capsule with an attached monolayer of lens epithelial cells (LECs) were obtained from patients (=52) undergoing cataract surgery. Specimens were divided into three groups based on the type of cataract: nuclear cataract, cortical cataract and posterior subcapsular cataract (PSC).

  5. SURGICAL INTERVENTION AND ACCOMMODATIVE RESPONSES: I. CENTRIPETAL CILIARY BODY, CAPSULE AND LENS MOVEMENT IN RHESUS MONKEYS OF VARYING AGE

    Science.gov (United States)

    Croft, Mary Ann; Mcdonald, Jared P.; James, Rebecca J.; Heatley, Gregg A.; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.

    2009-01-01

    Purpose To determine how surgically altering the normal relationship between the lens and the ciliary body in rhesus monkeys affects centripetal ciliary body and lens movement. Methods In 18 rhesus monkey eyes (aged 6–27 years), accommodation was induced before and after surgery by electrical stimulation of the Edinger-Westphal (E–W) nucleus. Accommodative amplitude was measured by coincidence refractometry. Goniovideography was performed before and after intra- and extra-capsular lens extraction (ICLE, ECLE) and anterior regional zonulolysis. Centripetal lens/capsule movements, centripetal ciliary process (CP) movements, and circumlental space were measured by computerized image analysis of the goniovideography images. Results Centripetal accommodative CP and capsule movement increased in velocity and amplitude post-ECLE compared to pre-ECLE regardless of age (n=5). The presence of the lens substance retarded capsule movement by ~21% in the young eyes and by ~62% in the older eyes. Post-ICLE compared to pre-ICLE centripetal accommodative CP movement was dampened in all eyes in which the anterior vitreous was disturbed (n=7), but not in eyes in which the anterior vitreous was left intact (n=2). Following anterior regional zonulolysis (n=4), lens position shifted toward the lysed quadrant during accommodation. Conclusions The presence of the lens substance, capsule zonular attachments, and Wiegers ligament may play a role in centripetal CP movement. The capsule is still capable of centripetal movement in the older eye (although at a reduced capacity) and may have the ability to produce ~6 diopters of accommodation in the presence of a normal young crystalline lens or a similar surrogate. PMID:18552393

  6. Spontaneous bilateral anterior partial in-the-bag intraocular lens dislocation following routine annual eye examination.

    Science.gov (United States)

    Ford, Joshua R; Werner, Liliana; Owen, Leah; Vasavada, Shail A; Crandall, Alan

    2014-09-01

    We present the case of an 81-year-old man with pseudoexfoliation syndrome (PXF) in whom spontaneous bilateral anterior partial in-the-bag intraocular lens (IOL) dislocation was diagnosed following a routine dilated examination that demonstrated only mild pseudophacodonesis with no evidence of subluxation. Uneventful cataract surgery with placement of single-piece hydrophobic acrylic posterior chamber IOLs had been performed in both eyes 7 years previously. Bilateral IOL repositioning with scleral fixation was performed to correct the dislocation. Postoperative examinations showed remarkable improvement in visual acuity and IOL stability. We hypothesize that zonular weakness secondary to PXF predisposed the patient to bilateral IOL partial dislocation. Pupil dilation in the setting of mild pseudophacodonesis at the time of routine examination may have been a precipitating factor. To our knowledge, bilateral IOL subluxation/dislocation has been described in a limited number of case reports. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens

    Directory of Open Access Journals (Sweden)

    Vikas Veerwal

    2017-01-01

    Full Text Available Pigment dispersion syndrome (PDS is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  8. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens.

    Science.gov (United States)

    Veerwal, Vikas; Goyal, Jawahar Lal; Jain, Parul; Arora, Ritu

    2017-01-01

    Pigment dispersion syndrome (PDS) is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA) of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  9. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    Directory of Open Access Journals (Sweden)

    Andleeb Zafar

    2018-02-01

    Full Text Available Purpose: We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods: The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK, and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results: Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion: A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  10. Allogeneic tumor cell vaccines

    Science.gov (United States)

    Srivatsan, Sanjay; Patel, Jaina M; Bozeman, Erica N; Imasuen, Imade E; He, Sara; Daniels, Danielle; Selvaraj, Periasamy

    2014-01-01

    The high mortality rate associated with cancer and its resistance to conventional treatments such as radiation and chemotherapy has led to the investigation of a variety of anti-cancer immunotherapies. The development of novel immunotherapies has been bolstered by the discovery of tumor-associated antigens (TAAs), through gene sequencing and proteomics. One such immunotherapy employs established allogeneic human cancer cell lines to induce antitumor immunity in patients through TAA presentation. Allogeneic cancer immunotherapies are desirable in a clinical setting due to their ease of production and availability. This review aims to summarize clinical trials of allogeneic tumor immunotherapies in various cancer types. To date, clinical trials have shown limited success due potentially to extensive degrees of inter- and intra-tumoral heterogeneity found among cancer patients. However, these clinical results provide guidance for the rational design and creation of more effective allogeneic tumor immunotherapies for use as monotherapies or in combination with other therapies. PMID:24064957

  11. Encephalitozoon cuniculi causes focal anterior cataract and uveitis in dogs.

    Science.gov (United States)

    Nell, B; Csokai, J; Fuchs-Baumgartinger, A; Maaß, G

    2015-01-01

    Three mongrel dogs, aged 10 months (case 1), 14 months (case 2) and 7.5 years (case 3), were presented because of ophthalmologic disorders of 4 months, 6 months and 7 years duration, respectively. All three dogs were offspring of stray dogs from Hungary and Serbia and had positive serum antibody titres against Encephalitozoon (E.) cuniculi. The two young dogs showed unilateral, the older dog bilateral chronic anterior uveitis with posterior synechia and focal anterior cortical cataract. The fundi that could be evaluated developed focal tapetal hyporeflective lesions in the course of the disease. Dogs 1 and 2 underwent removal of the lens via phacoemulsification. PCR of the lens material was positive for E. cuniculi strains IV and II, respectively. In dog 2 findings suggestive of microsporidia were detected underneath the anterior lens capsule by immunohistochemical staining. In all cases medical treatment consisted of systemic fenbendazole, prednisolone, and topical anti-inflammatory drugs, and additional brinzolamid/timolol for dog 3. For the time being all cases (follow up 23 months, 6 months and 3 months, respectively) are still on topical anti-inflammatory therapy. It is concluded that E. cuniculi infections can cause cataract and chorioretinal lesions in dogs.

  12. Application of ultrasound biomicro-scopy in the planning of cataract surgery in anterior megalophthalmos

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Zare

    2011-01-01

    Full Text Available Anterior megalophthalmos, a rare hereditary disorder, is macrocornea (horizontal corneal diameter more than 13 mm in association with enlarged lens-iris diaphragm and ciliary ring. One of the major challenging issues in the cataract surgery of these patients is preventing intraocular lens (IOL malposition, because of probable large capsular bag. Several approaches have been selected by previous surgeons, such as, custom-made anterior chamber IOLs. In this study, we show a normal capsular bag diameter despite ciliary ring enlargement, with application of ultrasound biomicroscopy (UMB. We suggest that in cases of anterior megalophthalmos without phacodonesis, UBM could measure the actual size of the capsular bag and obviate the need for further procedures.

  13. Morphologic Patterns Formed by the Anomalous Fibers Occurring Along the Anterior Capsule of the Crystalline Lens in People With the Long Anterior Zonule Trait.

    Science.gov (United States)

    Roberts, Daniel K; Yang, Yongyi; Morettin, Christina E; Newman, Tricia L; Roberts, Mary F; Wilensky, Jacob T

    2017-07-01

    People with the long anterior zonule (LAZ) trait, which may have prevalence near 2%, have zonular fibers that extend more central than usual along the anterior capsule of the crystalline lens. The anomalous fibers can be observed in vivo with clinical slit lamp biomicroscopy after pharmacologic pupil dilation, and although minimally studied, the LAZ trait may have importance to glaucoma, retinal degeneration, and cataract surgery. To further characterize LAZ morphology, a custom computer program was used to trace LAZ fibers seen on retro-illumination photos acquired during previous study at an academic, urban eye care facility in Chicago, IL. There were 59 African-Americans (54 female; median age = 70 years, 53-91 years) included in the analysis. After initial review of the zonule tracings, we identified three basic LAZ patterns. We called one pattern (47% of right eyes) a "non-segmental LAZ pattern," which was predominated by fibers that could be visually traced to the dilated pupil border where they became obscured by the iris. Another pattern (35% of right eyes), the "segmental LAZ pattern," was predominated by fibers that appeared to terminate abruptly without detectable extension to the pupil border. The third pattern (18% of right eyes), the "mixed LAZ pattern," had a more equivalent mixture of the other two fiber morphologies. Compared to the "non-segmental" group, the "segmental" LAZ eyes had smaller central zonule-free zones (P < 0.0001), and they tended to exhibit fewer LAZ fibers (P = 0.07). These data improve understanding of LAZ clinical anatomy and may be helpful to future investigation. Anat Rec, 300:1336-1347, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. A medieval fallacy: the crystalline lens in the center of the eye

    Directory of Open Access Journals (Sweden)

    Leffler CT

    2016-04-01

    Full Text Available Christopher T Leffler,1 Tamer M Hadi,2 Akrithi Udupa,1 Stephen G Schwartz,3 Daniel Schwartz1 1Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, 2Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, TN, 3Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Objective: To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Background: Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Methods: Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Results: Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3–5.3 mm. Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Conclusion: Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly

  15. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  16. Effect of miR-138 on the antioxidant function of lens epithelial cells affected by age-related cataracts

    Directory of Open Access Journals (Sweden)

    Bo Lu

    2018-03-01

    Full Text Available AIM: To investigate the effects and mechanism of miR-138 in mediating the antioxidant function of lens epithelial cells affected by age-related cataracts. METHODS: Real-time quantitative PCR(RT-qPCRwas used to detect miR-138 expression in the anterior lens capsules of healthy people, the anterior lens capsules of patients with age-related cataracts, and human epithelial cell line(SRA01/04cells exposed to oxidative stress. A 2', 7'-dichloro-fluorescein diacetate(DCFH-DAprobe was used to measure the levels of endogenous reactive oxygen species(ROSin human lens epithelial cells(hLECsexposed to 400μmol/L H2O2 for 1h. SRA01/04 cells were transfected with either miR-138 mimics, mimic controls, miR-138 inhibitors or inhibitor controls. After 72h, these cells were exposed to 400μmol/L H2O2 for 1h, then p53 and Bax mRNA expression were measured using RT-qPCR. Expression of p53 and Bax protein were also measured by western blotting analysis. Finally, cell viability was assessed using an MTS assay. RESULTS: Compared to the control group, expression of miR-138 in the anterior lens capsules of age-related cataract patients and in SRA01/04 cells exposed to oxidative stress significantly increased(PPPPCONCLUSION: The expression of miR-138 is upregulated in the anterior lens capsules of age-related cataract patients. MiR-138 decreases the anti-oxidative stress capacity of lens epithelial cells by upregulating p53 and Bax, while inhibiting cell proliferation and repair. This finding suggests that miR-138 may play a key role in the development of age-related cataracts.

  17. Short-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.

    Science.gov (United States)

    Romero-Jiménez, Miguel; Santodomingo-Rubido, Jacinto; Flores-Rodríguez, Patricia; González-Méijome, Jose-Manuel

    2015-01-01

    To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-point-touch fitting approach. The lens' back optic zone radius (BOZR) was 0.4mm and 0.1mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p<0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p<0.05). Significant reduction was found over time in CCA (p=0.001) and anterior corneal asphericity in both groups (p<0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p<0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p<0.05). Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apical-touch was associated with greater corneal flattening in comparison to three-point-touch lens wear. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  18. Application and experience of anterior vitrectomy in phacoemulsification

    Directory of Open Access Journals (Sweden)

    Xiao-Bo Zeng

    2016-02-01

    Full Text Available AIM: To observe and discuss the clinical application and effect of anterior vitrectomy in phacoemulsification for the treatment of vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection.METHODS:Retrospective analysis of 28 cases(35 eyeswith cataract in whom vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and intraocular lens implantation and anterior vitrectomy were performed was conducted. RESULTS:Anterior vitrectomy for timely and accurate treatment for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification was satisfied. CONCLUSION: Anterior vitrectomy has good curative effect for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and is effective with less severe complications.

  19. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  20. Histopathologic evaluation of the anterior segment of eyes enucleated due to glaucoma secondary to primary lens displacement in 13 canine globes.

    Science.gov (United States)

    Alario, Anthony F; Pizzirani, Stefano; Pirie, Christopher G

    2013-07-01

    PURPOSE  To describe histologic anterior segment changes in eyes affected with primary lens displacement (PLD) and secondary glaucoma. METHODS  Histologic sections stained with H&E from canine eyes enucleated because of PLD and secondary glaucoma were examined. RESULTS  Thirteen eyes from 12 patients were evaluated. Four dogs were castrated males and eight spayed females. Median age was 8 years of age (range 3-13). Breeds included seven terriers and five other breeds. All eyes examined demonstrated varying degrees of inflammation involving the iris and cleft. Mononuclear and melanophagic infiltration of the cleft was found in all specimens. Four globes also showed polymorphonuclear infiltrate. Pre-iridal fibrovascular membranes were clearly identified in 10 of 13 eyes. Total inflammatory score was significantly greater in all globes examined compared with an age-matched group of normal dogs. The posterior pigmented iris epithelium demonstrated a consistent pattern of hyperplasia and/or hypertrophy and cystic degeneration, more prominent in the more central regions. In some cases, hyperplasia was of greatest severity in the mid-iris and associated with thinning or flattening of the pupillary region. CONCLUSIONS  These results suggest that lens instability may be associated with chronic inflammation and secondary glaucoma. Mechanical irritation from an unstable lens may result in hypertrophy and/or hyperplasia of the posterior pigmented iris epithelium and subsequent cellular exfoliation and release of melanin. An inflammatory reaction directly or indirectly related to melanin release may obstruct the outflow pathways ultimately leading to glaucoma and loss of vision. Use of topical steroids may be warranted in dogs with PLD. © 2012 American College of Veterinary Ophthalmologists.

  1. Linguatula serrata in the anterior chamber of the eye

    Directory of Open Access Journals (Sweden)

    Muna Bhende

    2014-01-01

    Full Text Available We report a case of intraocular Linguatula in healthy young female who presented with a history of trivial trauma, dislocated lens, inflammation and secondary glaucoma. A mobile worm was seen in the anterior chamber. Pars plana lensectomy and vitrectomy was planned to remove both the cataractous lens and the parasite during which the worm disappeared from view but was later recovered from the cassette fluid. It was identified as the nymphal form of Linguatula serrata (tongue worm.

  2. Analysis of causes of intraocular lens explantations in the material of Department of Ophthalmology, Medical University of Lodz.

    Science.gov (United States)

    Wilczyński, Michał; Wilczyńska, Olena; Omulecki, Wojciech

    2009-01-01

    Implantation of intraocular lenses (IOLS) has become a standard practice in cataract surgery, however, similar to any other type of surgery, using IOLs is not complication-free and sometimes explantation of intraocular lenses may be necessary. This study was to gather data and analyze causes of intraocular lens explantations, performed in the Department of Ophthalmology, Medical University of Łódź. The data were gathered from medical documentation of all patients who underwent intraocular lens removal from January 2003 to July 2006. The examined group consisted of 16 patients (16 eyes): 9 women (fraction 0.56), and 7 men (fraction 0.44), at the age from 21 to 82 years (mean age 62.4 years, SD +/- 15.5). In all patients IOL explantation was performed under local, peribulbar anaesthesia. Two groups of patients were distinguished: patients who had an anterior chamber lens explanted (3 patients, fraction 0.19) and patients who underwent posterior chamber lens explantation (13 patients, fraction 0.81). Causes of AC IOL explantations were: vaulting of the IOL (1 eye, fraction 0.06), luxation of the IOL to the vitreous cavity (1 eye, fraction 0.06), and painful eyeball after anterior chamber lens implantation (1 eye, fraction 0.06). Causes of PC IOL explantations were: subluxation of the IOL (6 eyes, fraction 0.38), luxation of the lens to the vitreous cavity (3 eyes, fraction 0.19), luxation of the lens to the anterior chamber (1 eye, fraction 0.06), endophthalmitis (2 eyes, fraction 0.13) and incorrect lens power (1 eye, fraction 0.06). In the majority of eyes (n = 13, fraction 0.81) the removed implant was replaced by another intraocular lens, but 3 eyes (fraction 0.19) were left aphakic. We did not observe serious intra- or early postoperative complications which might influence the final result of the operation.

  3. Anterior eye protection with orbital neoplasia

    International Nuclear Information System (INIS)

    Hancock, S.L.

    1986-01-01

    The administration of adequate doses of radiation to tumors involving the orbit and surrounding facial structures and sinuses is often complicated by the need to protect the sensitive ocular components, the lens and cornea. A technique has been devised that uses four photon beam fields and an optional electron field to treat the contents of both orbits and adjacent sinuses with effective, reproducible protection of cornea and lens. Essential features include: alignment of the corneal surfaces with the central plane of rotation of the treatment machine, use of a narrow eye block across the entire beam to shield a strip equal to the width of the cornea, positioned symmetrically across the central plane of rotation, fine alignment of the eye block with both corneal surfaces by altering pedestal angle, treatment with paired, wedged, anterior oblique fields to encompass desired orbital and sinus volumes with additional blocking placed as needed, and complementary, lateral strip fields using collimators set to eye block thickness to equalize dose in the posterior orbit shielded by the strip eye block. A similar anterior electron beam strip field may be added to boost the medial orbit and ethmoid regions covered by the eye block. Bite block head immobilization and easy, direct daily visualization of block position assures eye protection for each treatment and provides substantial reduction in dose to the cornea, lens and iris. Additional blocking may be incorporated to provide partial lacrimal and parotid sparing

  4. Corneal Collagen Cross-Linking Combined with an Artiflex Iris-Fixated Anterior Chamber Phakic Intraocular Lens Implantation in a Patient with Progressive Keratoconus

    Directory of Open Access Journals (Sweden)

    Sharif Hashmani

    2017-10-01

    Full Text Available We present here the case of a 24-year-old male who experienced progressive keratoconus and vision loss which adversely affected his ability to carry out everyday tasks. This landed him in the Hashmanis Hospital for consultation. He had a preoperative best corrected visual acuity of 6/12. He underwent multiple Oculus Pentacam examinations, which showed progressive keratoconus. Corneal collagen cross-linking (CXL was performed to stabilize his cornea and, subsequently, an Artiflex anterior chamber iris-fixated phakic intraocular lens (ACIF-PIOL was implanted to alleviate his refractive errors. The patient achieved a postoperative uncorrected visual acuity of 6/12. This report shows that CXL combined with ACIF-PIOL can be safe and effective in those with progressive keratoconus.

  5. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma.

    Science.gov (United States)

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. Non-comparative retrospective observational case series. 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. To take early treatment of traumatic lens

  6. Myo/Nog cells: targets for preventing the accumulation of skeletal muscle-like cells in the human lens.

    Directory of Open Access Journals (Sweden)

    Jacquelyn Gerhart

    Full Text Available Posterior capsule opacification (PCO is a vision impairing condition that arises in some patients following cataract surgery. The fibrotic form of PCO is caused by myofibroblasts that may emerge in the lens years after surgery. In the chick embryo lens, myofibroblasts are derived from Myo/Nog cells that are identified by their expression of the skeletal muscle specific transcription factor MyoD, the bone morphogenetic protein inhibitor Noggin, and the epitope recognized by the G8 monoclonal antibody. The goal of this study was to test the hypothesis that depletion of Myo/Nog cells will prevent the accumulation of myofibroblasts in human lens tissue. Myo/Nog cells were present in anterior, equatorial and bow regions of the human lens, cornea and ciliary processes. In anterior lens tissue removed by capsulorhexis, Myo/Nog cells had synthesized myofibroblast and skeletal muscle proteins, including vimentin, MyoD and sarcomeric myosin. Alpha smooth muscle actin (α-SMA was detected in a subpopulation of Myo/Nog cells. Areas of the capsule denuded of epithelial cells were surrounded by Myo/Nog cells. Some of these cell free areas contained a wrinkle in the capsule. Depletion of Myo/Nog cells eliminated cells expressing skeletal muscle proteins in 5-day cultures but did not affect cells immunoreactive for beaded filament proteins that accumulate in differentiating lens epithelial cells. Transforming growth factor-betas 1 and 2 that mediate an epithelial-mesenchymal transition, did not induce the expression of skeletal muscle proteins in lens cells following Myo/Nog cell depletion. This study demonstrates that Myo/Nog cells in anterior lens tissue removed from cataract patients have undergone a partial differentiation to skeletal muscle. Myo/Nog cells appear to be the source of skeletal muscle-like cells in explants of human lens tissue. Targeting Myo/Nog cells with the G8 antibody during cataract surgery may reduce the incidence of PCO.

  7. Bony Reconstruction of the Anterior Glenoid Rim.

    Science.gov (United States)

    Willemot, Laurent B; Elhassan, Bassem T; Verborgt, Olivier

    2018-04-13

    Recurrent anterior shoulder instability is associated with glenohumeral bone loss. Glenoid deficiency compromises the concavity-compression mechanism. Medial Hill-Sachs lesions can result in an off-track humeral position. Anterior glenoid reconstruction or augmentation prevents recurrence by addressing the pathomechanics. In Bristow and Latarjet procedures, the coracoid process is harvested for conjoint tendon transfer, capsular reinforcement, and glenoid rim restoration. Complications and the nonanatomic nature of the procedure have spurred research on graft sources. The iliac crest is preferred for autogenous structural grafts. Tricortical, bicortical, and J-bone grafts have shown promising results despite the historical association of Eden-Hybinette procedures with early degenerative joint disease. Allogeneic osteochondral grafts may minimize the risk of arthropathy and donor site morbidity. Tibial plafond and glenoid allografts more closely match the native glenoid geometry and restore the articular chondral environment, compared with conventional grafts. Graft availability, cost, risk of disease transmission, and low chondrocyte viability have slowed the acceptance of osteochondral allografts.

  8. Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

    Science.gov (United States)

    Hirashima, Denise E; Soriano, Eduardo S; Meirelles, Rodrigo L; Alberti, Gustave N; Nosé, Walton

    2010-08-01

    To compare the outcome of phacoemulsification using 2 different iris-fixation techniques for intraocular lens (IOL) replacement, a foldable posterior chamber IOL (PCIOL; AcrySof MA60AC, Alcon Laboratories Inc, Fort Worth, TX) and an iris-claw anterior chamber IOL (ACIOL; Artisan, Ophtec BV), for treatment of subluxated lenses in patients with Marfan syndrome (MFS). Randomized, controlled trial. A total of 31 eyes of 16 patients with subluxated lenses associated with MFS and a preoperative corrected visual acuity (CVA) IOL type. Preoperative and postoperative ophthalmologic examination, optical coherence tomography, and endothelial cell counts were performed. We recorded CVA results at 3, 6, and 12 months, complications, endothelial cell loss, and central retinal thickness. In the iris-fixated PCIOL group, CVA was significantly improved at 3 (P = 0.011; n = 16), 6 (P = 0.006; n = 16), and 12 months (P = 0.002; n = 16). In the iris-claw ACIOL group, CVA was significantly improved at 3 (P = 0.001; n=15), 6 (P = 0.001; n = 15), and 12 months (P = 0.009; n = 12). The CVA results did not differ significantly between groups. Dislocation of the IOL occurred in 3 of 16 (18.75%) eyes in the PCIOL group. Retinal detachment occurred in 3 eyes (2 in the PCIOL group and 1 in the ACIOL group) and was successfully repaired. Postoperative foveal tomograms in both groups revealed a decrease in the mean foveal thickness (MFT; IOL dislocation tended to occur more frequently in the iris-fixated PCIOL group, the difference was not significant. At 6 months postoperatively, all study patients tended to have a thinner MFT. None of the patients in either group developed cystoid macular edema. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  9. A and B mode ultrasonography in preoperative evaluation of lens and posterior segment of dogs eyes with cataract

    Directory of Open Access Journals (Sweden)

    Bianca C. Martins

    2010-02-01

    Full Text Available Ultrasonography of the lens and posterior segment is an indispensable step in the preoperative evaluation of dogs with cataracts, since ophthalmoscopy is not feasible when there is opacification of the lens. This study evaluated the echographic conditions of cataractous lens and fundus of the eye in dogs affected by cataracts. The study was conducted in 30 dogs (56 eyes, 10 males and 20 females, with different types of cataracts at different stages of development. Echography in A and B modes, simultaneously, was carried out for the examination of the lens and posterior segment. The examinations revealed anterior cortical, posterior cortical and nuclear cataract in 12 eyes (21.4%, anterior cortical, posterior cortical, nuclear and posterior capsular in 23 eyes (41%, anterior cortical, posterior cortical and posterior capsular cataract in one eye (1.7%, anterior cortical and nuclear cataract in one eye (1.7%, anterior cortical, nuclear and posterior capsular cataract in five eyes (8.9%, and anterior cortical cataract in seven eyes (12.5%. Abnormal ultrasonographic alterations were observed in the posterior segment in 26 eyes evaluated (46.4%. Vitreal degeneration was detected in 12 eyes (21.4%, images of vitreal exudate or hemorrhage in seven eyes (12.5%, persistence of hyaloid artery in four eyes (7.1% and lens subluxation in three eyes (5.3%. The results obtained reiterate the importance of ultrasonography in canine patients presented for cataract surgery given that alterations of the posterior segment are difficult to identify in a clinical examination when the lens is opacified.A ultrassonografia do segmento posterior do bulbo do olho é etapa indispensável na avaliação de cães com catarata que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Este estudo avaliou as condições ecográficas da lente cataratogênica e do fundo de olho de c

  10. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  11. Transglutaminase involvement in UV-A damage to the eye lens

    International Nuclear Information System (INIS)

    Weinreb, Orly; Dovrat, A.

    1996-01-01

    Solar radiation is believed to be one of the major environmental factors involved in lens cataractogenesis. The purpose of the study was to investigate the mechanisms by which UV-A at 365 nm causes damage to the eye lens. Bovine lenses were placed in special culture cells for pre-incubation of 24 hr. The lenses were positioned so that the anterior surface faced the incident UV-A radiation source and were maintained in the cells during irradiation. After irradiation, lens optical quality was monitored throughout the culture period and lens epithelium, cortex and nuclear samples were taken for biochemical analysis. Transglutaminase activity in the lens was affected by the radiation. The activity of transglutaminase in lens epithelium cortex and nucleus increased as a result of the irradiation and then declined towards control levels during the culture period, as the lens recovered from the UV-A damage. Specific lens proteins αB and βB1 crystallins (the enzyme substrates) were analyzed by SDS polyacrylamid gel electrophoreses and immunoblotting with specific antibodies. Seventy-two hours after irradiation of 44.8 J cm -2 UV-A, αB crystallins were affected as was shown by the appearance of aggregation and degradation products. Some protein changes seem to be reversible. It appears that transglutaminase may be involved in the mechanism by which UV-A causes damage to the eye lens. (Author)

  12. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  13. Anterior dislocation of an empty capsular bag in a pseudophakic eye: A rare case report

    Directory of Open Access Journals (Sweden)

    Hyung Bin Hwang

    2015-01-01

    Full Text Available Spontaneous intraocular lens (IOL dislocation is uncommon in the absence of any ocular areas with zonular weakness or trauma. There have been no reports of spontaneous capsular bag dislocation into the anterior chamber without an IOL. We report a rare, interesting case of spontaneous capsular bag anterior dislocation, without an IOL, into the anterior chamber with no history of genetic disease, ocular trauma, or pseudoexfoliation that might predispose to a zonular abnormality.

  14. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-04-01

    Full Text Available AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi''an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures:visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations.RESULTS: The follow-up time was 11-36mo (21.4±7.13. Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL

  15. Applanation tonometry in silicone hydrogel contact lens wearers.

    Science.gov (United States)

    Allen, R J; Dev Borman, A; Saleh, G M

    2007-12-01

    Previous studies have investigated intraocular pressure (IOP) measurements through conventional soft (hydrogel) therapeutic contact lenses, and have found that an accurate IOP can be recorded in normal eyes, and in eyes with abnormal anterior segments. The IOP measurement through soft contact lenses may be affected by the water content and centre thickness of the lens. Silicone hydrogel contact lenses are now being used as therapeutic contact lenses due to their high oxygen permeability. The purpose of this study is to investigate if IOP can be accurately measured in a subject wearing a silicone hydrogel contact lens. In a cohort study, the IOP was measured with a Goldmann applanation tonometer without a contact lens and then repeated with a hydrogel contact lens in situ. The IOP of 20 eyes of 10 volunteers with no ocular pathology was measured. The mean difference (+/-S.D.) found between IOP measurement with (mean 15.55+/-1.70 mmHg) and without (mean 16.05+/-1.90 mmHg) contact lens was found to be -0.5+/-0.89 mmHg. Statistical analysis was performed which revealed a correlation coefficient of 0.89. No significant statistical difference was found between the two groups with paired t-test (p=0.19). Accurate measurement of IOP by applanation tonometry can be achieved through a silicone hydrogel contact lens.

  16. β1-integrin controls cell fate specification in early lens development

    Science.gov (United States)

    Pathania, Mallika; Wang, Yan; Simirskii, Vladimir N.; Duncan, Melinda K.

    2016-01-01

    Integrins are heterodimeric cell surface molecules that mediate cell-extracellular matrix (ECM) adhesion, ECM assembly, and regulation of both ECM and growth factor induced signaling. However, the developmental context of these diverse functions is not clear. Loss of β1-integrin from the lens vesicle (mouse E10.5) results in abnormal exit of anterior lens epithelial cells (LECs) from the cell cycle and their aberrant elongation toward the presumptive cornea by E12.5. These cells lose expression of LEC markers and initiate expression of the Maf (also known as c-Maf) and Prox1 transcription factors as well as other lens fiber cell markers, β1-integrin null LECs also upregulate the ERK, AKT and Smad1/5/8 phosphorylation indicative of BMP and FGF signaling. By E14.5, β1-integrin null lenses have undergone a complete conversion of all lens epithelial cells into fiber cells. These data suggest that shortly after lens vesicle closure, β1-integrin blocks inappropriate differentiation of the lens epithelium into fibers, potentially by inhibiting BMP and/or FGF receptor activation. Thus, β1-integrin has an important role in fine-tuning the response of the early lens to the gradient of growth factors that regulate lens fiber cell differentiation. PMID:27596755

  17. Neodymium:YAG laser cutting of intraocular lens haptics.

    Science.gov (United States)

    Gorn, R A; Steinert, R F

    1985-11-01

    Neodymium:YAG laser cutting of polymethylmethacrylate and polypropylene anterior chamber and posterior chamber intraocular lens haptics was studied in terms of ease of transection and physical structure of the cut areas as seen by scanning electron microscopy. A marked difference was discovered, with the polymethylmethacrylate cutting easily along transverse planes, whereas the polypropylene resisted cutting along longitudinal fibers. Clinical guidelines are presented.

  18. Kidney dysfunction after allogeneic stem cell transplantation

    NARCIS (Netherlands)

    Kersting, S.

    2008-01-01

    Allogeneic stem cell transplantation (SCT) is a widely accepted approach for malignant and nonmalignant hematopoietic diseases. Unfortunately complications can occur because of the treatment, leading to treatment-related mortality. We studied kidney dysfunction after allogeneic SCT in 2 cohorts of

  19. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  20. Calculation of crystalline lens power in chickens with a customized version of Bennett's equation.

    Science.gov (United States)

    Iribarren, Rafael; Rozema, Jos J; Schaeffel, Frank; Morgan, Ian G

    2014-03-01

    This paper customizes Bennett's equation for calculating lens power in chicken eyes from refraction, keratometry and biometry. Previously published data on refraction, corneal power, anterior chamber depth, lens thickness, lens radii of curvature, axial length and eye power in chickens aged 10-90 days were used to estimate Gullstrand's lens power and Bennett's lens power for chicken eyes, and to calculate the lens equivalent refractive index. Bennett's A and B constants for the front and back surface powers of the lens were calculated for data measured from day 10 to 90 at 10 day intervals, and mean customized constants were calculated. The mean customized constants for Bennett's equation for chicks were A=0.574±0.023 and B=0.379±0.021. As found previously, lens power decreases with age in chicks, while corneal power decreases and axial length increases. The lens equivalent refractive index decreases with age from 10 to 90 days after hatching. Bennett's equation can be used to calculate lens power in chicken eyes for studies on animal myopia, using standard biometry. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Present and future of allogeneic natural killer cell therapy

    Directory of Open Access Journals (Sweden)

    Okjae eLim

    2015-06-01

    Full Text Available Natural killer (NK cells are innate lymphocytes that are capable of eliminating tumor cells and are therefore used for cancer therapy. Although many early investigators used autologous NK cells, including lymphokine-activated killer cells, the clinical efficacies were not satisfactory. Meanwhile, human leukocyte antigen (HLA-haploidentical hematopoietic stem cell transplantation revealed the anti-tumor effect of allogeneic NK cells, and HLA-haploidentical, killer cell immunoglobulin-like receptor (KIR ligand-mismatched allogeneic NK cells are currently used for many protocols requiring NK cells. Moreover, allogeneic NK cells from non-HLA-related healthy donors have been recently used in cancer therapy. The use of allogeneic NK cells from non-HLA-related healthy donors allows the selection of donor NK cells with higher flexibility and to prepare expanded, cryopreserved NK cells for instant administration without delay for ex vivo expansion. In cancer therapy with allogeneic NK cells, optimal matching of donors and recipients is important to maximize the efficacy of the therapy. In this review, we summarize the present state of allogeneic NK cell therapy and its future directions.

  2. Crystalline lens thickness determines the perceived chromatic difference in magnification.

    Science.gov (United States)

    Chen, Yun; Schaeffel, Frank

    2014-03-01

    Since the origin of the high interindividual variability of the chromatic difference in retinal image magnification (CDM) in the human eye is not well understood, optical parameters that might determine its magnitude were studied in 21 healthy subjects with ages ranging from 21 to 58 years. Two psychophysical procedures were used to quantify CDM. They produced highly correlated results. First, a red and a blue square, presented on a black screen, had to be matched in size by the subjects with their right eyes. Second, a filled red and blue square, flickering on top of each other at 2 Hz, had to be adjusted in perceived brightness and then in size to minimize the impression of flicker. CDM varied widely among subjects from 0.0% to 3.6%. Biometric ocular parameters were measured with low coherence interferometry and crystalline lens tilt and decentration with a custom-built Purkinjemeter. Correlations were studied between CDM and corneal power, anterior chamber depth, lens thickness, lens tilt and lens decentration, and vitreous chamber depths. Lens thickness was found significantly correlated with CDM and accounted for 64% of its variance. Vertical lens tilt and decentration were also significantly correlated. It was also found that CDM increased by 3.5% per year, and part of this change can be attributed to the age-related increase in lens thickness.

  3. Slit-lamp Needling of the Anterior Capsule for Aqueous Misdirection After Hyaloido-zonulectomy and Iridectomy.

    Science.gov (United States)

    Mardelli, Pierre G; Mardelli, Marc E

    2018-04-01

    We present a case of persistent aqueous misdirection, after Ahmed glaucoma valve surgery, despite undergoing an anterior vitrectomy with hyaloido-zonulectomy and iridectomy. A 73-year-old female patient, 4 months after phacotrabeculectomy, was referred with persistent high intraocular pressure (IOP). Postoperatively, she developed aqueous misdirection with a flat anterior chamber (AC) but with an IOP of 15 mm Hg. On presentation, her AC was shallow with peripheral iris-cornea touch, and her IOP was 39 mm Hg. Posterior Nd:Yag capsulotomy with disruption of anterior hyaloid face partially deepened the AC. With failure of the trabeculectomy and high IOP, an Ahmed valve was placed. On the first operative day the AC was deep with an IOP of 10 mm Hg. On day 6 the patient presented with pain, flat AC, and an IOP of 10 mm Hg. Fundus examination revealed no choroidal effusion. Despite repeated reformation with viscoelastic, the AC failed to deepen. An anterior vitrectomy with hyaloido-zonulectomy was performed. Initially, the AC was deep, but, a few days later, it was flat. Multiple reformations and vitreous tap failed to keep the AC deep. A 30-G needle was passed at the slit lamp across the temporal cornea, iris, and anterior capsule into the anterior vitreous cavity. The needle was then partially withdrawn and used to create a space between the intraocular lens and anterior capsule. This immediately deepened the AC and remained so for the duration of follow-up (4 mo). Slit-lamp needling of the anterior lens capsule can be successfully performed to help resolve a persistent case of aqueous misdirection after anterior vitrectomy.

  4. Anterior segment morphology and morphometry in selected reptile species using optical coherence tomography.

    Science.gov (United States)

    Rival, Franck; Linsart, Adeline; Isard, Pierre-François; Besson, Christian; Dulaurent, Thomas

    2015-01-01

    To provide new and original images of the anterior segment (AS) of the eye of selected Ophidian, Chelonian, and Saurian species and to compare the AS architecture among and within these three groups. 17 Saurians, 14 Ophidians, and 11 Chelonians with no concurrent systemic or eye disease were included in the study. Age, weight, nose-cloaca distance (NCD), and pupil shape were collected for each animal. The AS was examined by optical coherence tomography (OCT). After gross description of the appearance of the AS, the central and peripheral corneal thickness (CCT, PCT) and anterior chamber depth (ACD) were measured using the software provided with the OCT device. The ratio CCT/ACD was then calculated for each animal. Pupil shape was a vertical slit in all the crepuscular or nocturnal animals (except for 1 chelonian and 1 ophidian). Each group had its own particular AS architecture. Saurians had a regularly thin cornea with a flat anterior lens capsule and a deep anterior chamber. Ophidians had a thick cornea with a narrow anterior chamber due to a very anteriorly anchored spherical lens. The spectacle was difficult to identify in all ophidians except in Python molurus bivitattus in which it was more obvious. Chelonians displayed an intermediate architecture which more closely resembled the Saurian type than the Ophidian type. Despite grossly similar AS architecture, the three groups of reptiles in the study demonstrated differences that are suggestive of a link between anatomical disparities and variations in environment and lifestyle. © 2014 American College of Veterinary Ophthalmologists.

  5. Anterior capsular support for posterior chamber intraocular lenses following vitreous loss in endocapsular surgery

    Directory of Open Access Journals (Sweden)

    Jacob Pushpa

    1993-01-01

    Full Text Available We used anterior capsular support for posterior chamber intraocular lenses (PC IOLs in fourteen eyes with large posterior capsular ruptures. An endocapsular technique preserved the anterior capsule and facilitated implantation. With a median follow up of 8.5 months, all patients had a visual acuity of 6/9 or better. One lens was lost in the vitreous and one patient had a clinically significant cystoid macular edema. In the event of a posterior capsular rupture we suggest this technique as an alternative to anterior chamber or scleral-fixated lenses

  6. Allogeneic hematopoietic cell transplantation (allogeneic HCT) for treatment of pediatric Philadelphia chromosome-positive acute lymphoblastic leukemia (ALL).

    Science.gov (United States)

    Burke, Michael J; Cao, Qing; Trotz, Barb; Weigel, Brenda; Kumar, Ashish; Smith, Angela; Verneris, Michael R

    2009-12-15

    Allogeneic hematopoietic cell transplant (HCT) with best available donor for children with Philadelphia positive (Ph+) acute lymphoblastic leukemia (ALL) has previously been considered standard practice. Since the introduction of imatinib into the treatment of this disease, the role of allogeneic HCT is more uncertain. We investigated the impact of remission status, graft source, and imatinib use on transplant outcomes for 37 children with Ph+ ALL who received an allogeneic HCT at the University of Minnesota between 1990 and 2006. The median age at HCT was 7.47 (range; 1.4-16.4) years. Thirteen patients received imatinib therapy pre- and/or post-HCT (imatinib group) and 24 patients, received either no imatinib (n = 23) or only post-HCT relapse (n = 1) (non-imatinib group). There was no difference in disease-free survival (DFS) or relapse between the imatinib and non-imatinib groups at 3 years (62%/15% vs. 53%/26%; P = 0.99; 0.81, respectively). There was no significant difference in transplant outcomes between matched related donor or unrelated donor (umbilical cord blood or matched unrelated marrow) recipients whereas patients receiving allogeneic HCT in first remission (CR1) had superior DFS and less relapse compared to patients transplanted in >or=CR2 (71%/16% vs. 29%/36%; P = 0.01; P = 0.05). Based on this retrospective analysis at a single institution, the use of imatinib either pre- and/or post-transplant does not appear to significantly impact outcomes for children with Ph+ ALL and allogeneic HCT with the best available donor should be encouraged in CR1.

  7. Pigmented striae of the anterior lens capsule and age-associated pigment dispersion of variable degree in a group of older African-Americans: an age, race, and gender matched study.

    Science.gov (United States)

    Roberts, D K; Winters, J E; Castells, D D; Clark, C A; Teitelbaum, B A

    2001-01-01

    To investigate pigmented striae of the anterior lens capsule in African-Americans, a potential indicator of significant anterior segment pigment dispersion. A group of 40 African-American subjects who exhibited pigmented lens striae (PLS) were identified from a non-referred, primary eye care population in Chicago, IL, USA. These subjects were then compared to an age, race, and gender matched control group relative to refractive error and the presence or absence of diabetes and hypertension. The PLS subjects (mean age = 65.4 +/- 8.8 years, range = 50-87 years) consisted of 36 females and 4 males. PLS were bilateral in 36 (85%) of the 40 subjects. Among the eyes with PLS, 21 (55%) of 38 right eyes and 22 (61%) of 36 left eyes also had significant corneal endothelial pigment dusting, commonly in the shape of a Krukenberg's spindle. Ten (25%) of the PLS subjects had either glaucoma or ocular hypertension (7 bilateral, 3 unilateral). The presence of trabecular meshwork pigment varied from minimal to heavy. The mean +/- SD (range) refractive error of the PLS right eyes was +1.61 +/- 1.43D (-1.50 to +5.00D) and +1.77 +/- 1.37D (-1.00 to +5.00D) for the left eyes. Based on these data, the PLS right eyes were +1.63D (Student's t, p = 0.0001; 95% CI = +0.82 to +2.44D) more hyperopic on average than the control right eyes, and the PLS left eyes were +1.77D (p = 0.0001; 95% CI = +0.92 to +2.63D) more hyperopic on average than the control left eyes. Trend analysis showed a gradually increasing likelihood of PLS with increasing magnitude of hyperopia in both eyes (Mantel-Haenszel chi-square, p = 0.001). Among PLS subjects, 24 (60%) of 40 were hypertensive and 9 (23%) of 40 were diabetic. However, these proportions were not significantly different (two-tailed Fisher's exact test; hypertension: p = 0.30; diabetes: p = 0.70) from the randomly selected controls. Among our African-American group, which consisted predominately of females >50 years of age, the likelihood of PLS

  8. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  9. Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma

    International Nuclear Information System (INIS)

    Daftari, Inder K.; Char, Devron H.; Verhey, Lynn J.; Castro, Joseph R.; Petti, Paula L.; Meecham, William J.; Kroll, Stewart; Blakely, Eleanor A.

    1997-01-01

    Purpose: The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. Methods and Materials: 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. Results: NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. Conclusion: The development of NVG after

  10. Allogenic lyophilized cartilage grafts for craniomaxillofacial reconstruction

    International Nuclear Information System (INIS)

    Pill Hoon Choung

    1999-01-01

    Allogenic lyophilized cartilages were made in our clinic after Sailer methods and some modification. In our clinic, we have used allogenic cartilage grafts on 102 defects of craniomaxillofacial area; 1) for defects from cyst or ameloblastoma, 2) for lack of continuity of the mandible, 3) for rhinoplasty, 4) for paranasal augmentation, 5) for augmentation genioplasty, 6) for reconstruction of orbital floor, 7) for oroantral fistula, 8) for temporal augmentation, 9) for TMJ surgery 10) for condyle defect as a costochondral graft, 11) for filling of tooth socket and alveolus augmentation,12) for correction or orbital height and 13) for guided bone regeneration in peripheral implant. The types of lyophilized cartilage used were chip, sheet and block types developed by freeze-dried methods. Some grafts showed change of ossification, in which case we could perform implant on it. We have good results on reconstruction of craniomaxillofacial defects. Allogenic cartilage have advantages such as 1) it has no immune reaction clinically, 2) it is more tolerable to infection than that of autogenous cartilage, 3) it has character of less resorption which require no over correction, 4) it is easy to manipulate contouring, and 5) it has possibility of undergoing ossification. Allogenic cartilage has been considered as good substitutes for bone. The author would like to report the results on 102 allogenic cartilage have

  11. Lyophilized allogeneic bone grafts for cystic and discontinuity defects of the jaws

    International Nuclear Information System (INIS)

    Pill Hoon Choung; Eun Seok Kim

    1999-01-01

    Allogenic bone grafts have been used after various processing in each institute was made by lyophilized allogenic bone and used for maxillofacial reconstruction. Three types of lyophilized allogenic bone grafts as powder, chip and block form were performed to reconstruct the following defects: 1) maxillectomy, 2) mandiblectomy, 3) cystectomy, 4) cleft alveolus, 5) gap in orthognathic osteotomy, 6) peri-implant defect, 7) extraction socket, and 8) facial contouring. Above defects can be classified as cystic and discontinuity defects of the maxilia and the mandible. Because discontinuity defects have more difficult problems to reconstruct considering mechanical strength of the allogenic bone. We performed allogenic bone grafts on 50 cystic defects and 12 discontinuity defects of the jaws. Among them, 3 cases were removed due to infection, and the others had no complications. In reconstruction of cystic defects, the defects were filled with allogenic chip which were made from allogenic block bone at the surgery, which later were changed to host bone. Three cases of them showed tooth eruption through the allogenic bone grafting site, changing the eruption pathway, which was interrupted by the lesion. in reconstruction of discontinuity defects, usually allogenic bone has been used as a tray, in which PMCB or demineralized bone chips were filled. But we tried to reconstruct this discontinuity defect using allogeneic bone block without inside filling of PMCB different from tray type. We will present the results of allogenic bone grafts using cranial bone, costochondral graft, and the mandible

  12. Monitoring of a new approach of immunotherapy with allogenic 111In-labelled NK cells in patients with renal cell carcinoma

    International Nuclear Information System (INIS)

    Meller, Birgit; Lauer, Isabel; Schelper, Lutz F.; Hof, Katharina von; Richter, Eckart; Baehre, Manfred; Frohn, Christoph; Brand, Joerg-Matthias; Kirchner, Holger

    2004-01-01

    The transfusion of allogenic, in vitro expanded natural killer cells (NKC) is a novel therapy option in oncology. To date, however, the biodistribution and kinetics of allogenic NKC have not been investigated. Therefore, in this study three patients with renal cell carcinoma received 3-7 x 10 8 NKC labelled with indium-111 oxine with a tenfold excess of unlabelled cells during NKC therapy. Whole-body scintigrams were obtained (0.5-144 h) in the anterior and posterior views. Scintigrams were analysed using a region of interest technique, and single-photon emission tomography (SPET) studies of the abdomen were performed. Results were compared to those obtained with polymerase chain reaction (PCR) of the peripheral blood (determination of foreign DNA, nested PCR, limit of detection 0.01%). Shortly after transfusion of NKC, more than 50% of the activity was accumulated in the lungs. We observed redistribution effects from lungs to liver, spleen and bone marrow. No significant loss of activity could be detected. In two of four large metastases, tracer accumulation could be proven by SPET. As confirmed by scintigrams and PCR, the fraction of circulating transfused cells was low at all times. Long-term activity retention might be caused either by survival of the allogenic cells, as confirmed by PCR (up to 3 days p.i.), or by phagocytosis of labelled cellular fragments. However, PCR data and uptake in metastases indicated long survival of a portion of allogenic NKC. Such long survival and low retention of the cells in the lung are requirements for an effective immunotherapeutic approach. (orig.)

  13. Ocular findings after allogeneic hematopoietic stem cell transplantation.

    Science.gov (United States)

    Tabbara, Khalid F; Al-Ghamdi, Ahmad; Al-Mohareb, Fahad; Ayas, Mouhab; Chaudhri, Naeem; Al-Sharif, Fahad; Al-Zahrani, Hazzaa; Mohammed, Said Y; Nassar, Amr; Aljurf, Mahmoud

    2009-09-01

    To study the incidence, causes, and outcome of major ocular complications in patients undergoing allogeneic hematopoietic stem cell transplantation (HSCT). Retrospective, noncomparative, observational clinical study. The study included a total of 620 patients who underwent allogeneic HSCT in the period from 1997 to 2007 at King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia. Allogeneic HSCT. Patients with ocular complications were referred to the ophthalmology division for complete ophthalmologic examination, including visual acuity, tonometry, Schirmer test, biomicroscopy, and dilated ophthalmoscopy. Laboratory investigations were performed whenever indicated. The incidence and causes of major ocular complications after allogeneic HSCT were determined. Visual acuity at 1 year after allogeneic HSCT was recorded. Major ocular complications occurred in 80 (13%) of 620 patients who underwent allogeneic HSCT. There were 36 male patients (45%) and 44 female patients (55%) with a mean age of 29 years and an age range of 9 to 65 years. Prophylaxis for graft-versus-host disease (GVHD) consisted of cyclosporine and methotrexate in 69 patients, and cyclosporine, methotrexate and corticosteroids, or mycophenolate mofetil in 11 patients. The most frequently encountered ocular complications were chronic GVHD, dry eye syndrome without GVHD, corneal ulcers, cataract, glaucoma, cytomegalovirus retinitis, fungal endophthalmitis, and acquisition of allergic conjunctivitis from atopic donors. There was no correlation between the pattern of ocular complications and the transplanted stem cell source. Best-corrected visual acuity (BCVA) at 1 year after transplantation was less than 20/200 in 13 patients (16%), less than 20/50 in 17 patients (21%), and better than 20/50 in 50 patients (63%). Ocular complications are common in patients undergoing allogeneic HSCT. Early recognition and prompt treatment are important. The author(s) have no proprietary or commercial

  14. ALLOGENEIC TRANSPLANTATION FOR CHRONIC LYMPHOCYTIC LEUKEMIA

    Directory of Open Access Journals (Sweden)

    Luca Laurenti

    2010-08-01

    Full Text Available Even if Chronic lymphocytic leukemia (CLL often has an indolent behavior with good responsiveness to cytoreductive treatment, about 20% of the patients, so called "poor-risk" patients, show an aggressive course and die within a few years despite early intensive therapies. Criteria for poor-risk disease according to the European Bone Marrow Transplantation (EBMT CLL Transplant Consensus are: purine analogue refractoriness, early relapse after purine analogue combination therapy, CLL with p53 lesion requiring treatment. Allogeneic transplant has potential curative role in CLL, however burden with very  high transplant related mortality (TRM rates of 38-50%: A major advance in reducing the short-term morbidity and mortality of allogeneic stem cell transplantation (SCT has been the introduction of non-myeloablative or reduced intensity conditioning (RIC regimens to allow engraftment of allogeneic stem cells. There is no doubt that the crucial therapeutic principle of allo-SCT in CLL is graft versus leukemia (GVL activity. The major complications of allogeneic SCT in CLL are: chronic graft-versus-host-disease (GVHD affecting quality of life, high graft rejection and infection rates rates correlated with preexisting immunosuppression. Disease relapse remains the major cause of failure after RIC allo-HCT in CLL patients. Sensitive minimal residual disease (MRD quantification has strong prognostic impact after transplant.

  15. Citation parameters of contact lens-related articles published in the ophthalmic literature.

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2014-09-01

    This study aimed at exploring the citation parameters of contact lenses articles published in the Ophthalmology thematic category of the Journal Citation Reports (JCR). The Thompson Reuters Web of Science database was accessed to record bibliometric information and citation parameters of all journals listed under the Ophthalmology area of the 2011 JCR edition, including the journals with main publication interests in the contact lens field. In addition, the same database was used to unveil all contact lens-related articles published in 2011 in the same thematic area, whereupon differences in citation parameters between those articles published in contact lens and non-contact lens-related journals were explored. Significant differences in some bibliometric indicators such as half-life and overall citation count were found between contact lens-related journals (shorter half-life and fewer citations) and the median values for the Ophthalmology thematic area of the JCR. Visual examination of all Ophthalmology journals uncovered a total of 156 contact lens-related articles, published in 28 different journals, with 27 articles each for Contact Lens & Anterior Eye, Eye & Contact Lens, and Optometry and Vision Science. Significant differences in citation parameters were encountered between those articles published in contact lens and non-contact lens source journals. These findings, which disclosed contact lenses to be a fertile area of research, may be of interest to researchers and institutions. Differences in bibliometric indicators are of relevance to avoid unwanted bias when conducting between- and within-discipline comparisons of articles, journals, and researchers.

  16. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  17. Ocular Toxicity after High-Dose Cefuroxime Injection into the Anterior Chamber

    Directory of Open Access Journals (Sweden)

    Harun Çakmak

    2016-08-01

    Full Text Available Cephalosporins are beta-lactam antibiotics and, like penicillin derivatives, they show bacteriostatic effect by disrupting bacterial cell wall synthesis. Cefuroxime is a second generation cephalosporin and the use of intracameral cefuroxime after cataract surgery has been widely used in the endophthalmitis prophylaxis. A 78-year-old male patient was operated for cataracts in both eyes about 8 years ago. Ocular trauma has occurred in the left eye nine months ago. Vitrectomy surgery combined with intraocular lens extraction was performed and the patient was left aphakic. Secondary intraocular lens implantation was performed. In this paper, we present postoperative ocular findings in a patient who was given cefuroxime into the anterior chamber 2.5 times higher than the recommended dose (25 mg/ml after secondary intraocular lens implantation.

  18. Semiautomated analysis of optical coherence tomography crystalline lens images under simulated accommodation.

    Science.gov (United States)

    Kim, Eon; Ehrmann, Klaus; Uhlhorn, Stephen; Borja, David; Arrieta-Quintero, Esdras; Parel, Jean-Marie

    2011-05-01

    Presbyopia is an age related, gradual loss of accommodation, mainly due to changes in the crystalline lens. As part of research efforts to understand and cure this condition, ex vivo, cross-sectional optical coherence tomography images of crystalline lenses were obtained by using the Ex-Vivo Accommodation Simulator (EVAS II) instrument and analyzed to extract their physical and optical properties. Various filters and edge detection methods were applied to isolate the edge contour. An ellipse is fitted to the lens outline to obtain central reference point for transforming the pixel data into the analysis coordinate system. This allows for the fitting of a high order equation to obtain a mathematical description of the edge contour, which obeys constraints of continuity as well as zero to infinite surface slopes from apex to equator. Geometrical parameters of the lens were determined for the lens images captured at different accommodative states. Various curve fitting functions were developed to mathematically describe the anterior and posterior surfaces of the lens. Their differences were evaluated and their suitability for extracting optical performance of the lens was assessed. The robustness of these algorithms was tested by analyzing the same images repeated times.

  19. Catarata polar anterior piramidal deslocada para a câmara anterior causando edema de córnea: relato de caso Corneal edema caused by a pyramidal anterior polar cataract dislocated to the anterior chamber: case report

    Directory of Open Access Journals (Sweden)

    Ramon Coral Ghanem

    2004-08-01

    Full Text Available Cataratas polares anteriores piramidais são opacidades cônicas que se projetam para a câmara anterior a partir da cápsula anterior do cristalino. Na grande maioria dos pacientes a opacidade permanece aderida e estável durante toda a vida. O objetivo deste trabalho é documentar uma manifestação incomum desse tipo de catarata: a deiscência espontânea das pirâmides para a câmara anterior causando descompensação endotelial e edema corneal bilateral. Relatamos o caso de uma paciente feminina, de 66 anos, branca, que apresentava edema corneal localizado inferiormente no olho direito associado à lesão nodular branco-esclerótica compatível com a pirâmide anterior da catarata polar. O olho esquerdo apresentava edema corneal difuso intenso e presença de uma catarata polar anterior com a região piramidal deslocada para a câmara anterior. Sabe-se que a pirâmide anterior pode permanecer inabsorvida na câmara anterior por longo período, pois é composta de tecido colágeno denso. Isto causa perda endotelial progressiva e edema corneal e deve ser considerada indicação de remoção cirúrgica da catarata polar anterior e de seu fragmento. Ressalta-se, também, a importância do bom senso no julgamento das cataratas polares anteriores, considerando-se tamanho da opacidade, simetria das opacidades e componente cortical associado, na tentativa de se evitar ambliopia.Pyramidal anterior polar cataracts are conical opacities that project into the anterior chamber from the anterior capsule of the lens. In the vast majority of patients the opacity remains bound and stable throughout life. We report an unusual complication of this type of cataract: spontaneous dehiscence of the pyramids to the anterior chamber causing bilateral endothelial damage and corneal edema. 66-year-old white woman presented with inferior corneal edema in the right eye and diffuse corneal edema in the left eye. A white nodular lesion was observed in the inferior angle

  20. A novel lens epithelium gene, LEP503, is highly conserved in different vertebrate species and is developmentally regulated in postnatal rat lens.

    Science.gov (United States)

    Wen, Y; Sachs, G; Athmann, C

    2000-02-01

    The development of the lens is dependent on the proliferation of lens epithelial cells and their differentiation into fiber cells near the lens bow/equator. Identification of genes specifically expressed in the lens epithelial cells and their functions may provide insight into molecular events that regulate the processes of lens epithelial cell differentiation. In this study, a novel lens epithelium gene product, LEP503, identified from rat by a subtractive cDNA cloning strategy was investigated in the genome organization, mRNA expression and protein localization. The genomic sequences for LEP503 isolated from rat, mouse and human span 1754 bp, 1694 bp and 1895 bp regions encompassing the 5'-flanking region, two exons, one intron and 3'-flanking region. All exon-intron junction sequences conform to the GT/AG rule. Both mouse and human LEP503 genes show very high identity (93% for mouse and 79% for human) to rat LEP503 gene in the exon 1 that contains an open reading frame coding for a protein of 61 amino acid residues with a leucine-rich domain. The deduced protein sequences also show high identity (91% between mouse and rat and 77% between human and rat). Western blot shows that LEP503 is present as a specific approximately 6.9 kDa band in the water-insoluble-urea-soluble fraction of lens cortex where lens epithelium is included. Immuno-staining shows that LEP503 is localized in the epithelial cells along the entire anterior surface of rat lens. Developmentally, LEP503 is expressed at a low level at newborn, and then the expression level increases by about ten-fold around postnatal day 14 and remains at this high level for about 25 days before it drops back to the low level by postnatal day 84. These data suggest that the LEP503 may be an important lens epithelial cell gene involving the processes of epithelial cell differentiation. Copyright 2000 Academic Press.

  1. Monitoring of a new approach of immunotherapy with allogenic {sup 111}In-labelled NK cells in patients with renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Meller, Birgit; Lauer, Isabel; Schelper, Lutz F.; Hof, Katharina von; Richter, Eckart; Baehre, Manfred [Clinic of Radiotherapy and Nuclear Medicine, University of Luebeck, Ratzeburger Allee 160, 23538, Luebeck (Germany); Frohn, Christoph; Brand, Joerg-Matthias; Kirchner, Holger [Institute of Immunology and Transfusion Medicine, University of Luebeck, Ratzeburger Allee 160, 23538, Luebeck (Germany)

    2004-03-01

    The transfusion of allogenic, in vitro expanded natural killer cells (NKC) is a novel therapy option in oncology. To date, however, the biodistribution and kinetics of allogenic NKC have not been investigated. Therefore, in this study three patients with renal cell carcinoma received 3-7 x 10{sup 8} NKC labelled with indium-111 oxine with a tenfold excess of unlabelled cells during NKC therapy. Whole-body scintigrams were obtained (0.5-144 h) in the anterior and posterior views. Scintigrams were analysed using a region of interest technique, and single-photon emission tomography (SPET) studies of the abdomen were performed. Results were compared to those obtained with polymerase chain reaction (PCR) of the peripheral blood (determination of foreign DNA, nested PCR, limit of detection 0.01%). Shortly after transfusion of NKC, more than 50% of the activity was accumulated in the lungs. We observed redistribution effects from lungs to liver, spleen and bone marrow. No significant loss of activity could be detected. In two of four large metastases, tracer accumulation could be proven by SPET. As confirmed by scintigrams and PCR, the fraction of circulating transfused cells was low at all times. Long-term activity retention might be caused either by survival of the allogenic cells, as confirmed by PCR (up to 3 days p.i.), or by phagocytosis of labelled cellular fragments. However, PCR data and uptake in metastases indicated long survival of a portion of allogenic NKC. Such long survival and low retention of the cells in the lung are requirements for an effective immunotherapeutic approach. (orig.)

  2. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Bruna Vieira Ventura

    Full Text Available ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  3. A new technique for the closure of the lens capsule by laser welding.

    Science.gov (United States)

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  4. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    Science.gov (United States)

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  5. Capsular phimosis with complete occlusion of the anterior capsular opening after intact continuous curvilinear capsulorrhexis

    International Nuclear Information System (INIS)

    Al-Kharashi, Soliman A.; Al-Obailan, Majed

    2009-01-01

    Shrinkage and whitening of the anterior capsule opening - capsular contraction syndrome - is a well-known complication after continuous curvilinear capsulorrhexis. A 72-year-old women underwent continuous curvilinear capsulorrhexis, phacoemulsification, and implantation of posterior chamber intraocular lens with polymethylmethacrylate haptics. Four months postoperatively, the patient reported deterioration in visual acuity that was resulted due to complete occlusion of anterior capsular opening by fibrotic tissue. The fibrous membrane was excised surgically in capsulorrhexis fashion. (author)

  6. Single lens to lens duplication: The missing link

    OpenAIRE

    Bhatt, Rupal; Jethani, Jitendra; Saluja, Praveen; Bharti, Vinay

    2008-01-01

    Congenital anomalies of the lens include a wide range from lens coloboma to primary aphakia and doubling of lens. There have been few case reports of double lens; the etiology suggested is metaplastic changes in the surface ectoderm that leads to formation of two lens vesicles and hence resulting in double lens. We report a case with bilobed lens, which raises the possibility of explaining the etiology of double lens.

  7. Intraocular Lens Dislocation after Cataract Surgery in Tambolaka, Southwest Sumba, Indonesia: A Case Report

    OpenAIRE

    Ratna Sitompul

    2018-01-01

    Intraocular lens (IOL) dislocation is a rare complication of cataract extraction requiring prompt surgery. This case report aims to raise awareness of such cases and the importance of post-surgery follow-up. A 58-year-old female patient was found with anterior IOL dislocation a week after phacoemulsification surgery in her right eye. Visual acuity of the right eye was 1/60 with ciliary injection and IOL dislocation to the anterior chamber of the right eye. The patient underwent surgery of the...

  8. Kosten van allogene stamceltransplantaties

    NARCIS (Netherlands)

    M. van Agthoven (Michel); M.T. Groot (Martijn); C.A. Uyl-de Groot (Carin)

    2001-01-01

    textabstractAllogene stamceltransplantatie is een topspecialistische procedure die met succes kan worden ingezet in de behandeling van (hematologische) maligniteiten, met name bij leukemie. Van oudsher worden transplantaten van verwante donoren gebruikt, maar met de mogelijkheden om transplantaten

  9. Pseudomonas aeruginosa Survival at Posterior Contact Lens Surfaces after Daily Wear

    Science.gov (United States)

    Wu, Yvonne T.; Zhu, Lucia S.; Tam, K. P. Connie; Evans, David J.; Fleiszig, Suzanne M. J.

    2015-01-01

    Purpose Pseudomonas aeruginosa keratitis is a sight-threatening complication of contact lens wear, yet mechanisms by which lenses predispose to infection remain unclear. Here, we tested the hypothesis that tear fluid at the posterior contact lens surface can lose antimicrobial activity over time during lens wear. Methods Daily disposable lenses were worn for 1, 2, 4, 6 or 8 h immediately after removal from their packaging, or after presoaking in sterile saline for 2 days to remove packaging solution. Unworn lenses were also tested, some coated in tears “aged” in vitro for 1 or 8 h. Lenses were placed anterior surface down into tryptic soy agar cradles containing gentamicin (100µg/ml) to kill bacteria already on the lens, and posterior surfaces inoculated with gentamicin-resistant P. aeruginosa for 3 h. Surviving bacteria were enumerated by viable counts of lens homogenates. Results Posterior surfaces of lenses worn by patients for 8 h supported more P. aeruginosa growth than lenses worn for only 1 h, if lenses were presoaked prior to wear (~ 2.4-fold, p = 0.01). This increase was offset if lenses were not presoaked to remove packaging solution (p = 0.04 at 2 h and 4 h). Irrespective of presoaking, lenses worn for 8 h showed more growth on their posterior surface than unworn lenses coated with tear fluid that was “aged” for 8 h vitro (~8.6-fold, presoaked, p = 0.003: ~ 5.4-fold from packaging solution, p = 0.004). Indeed, in vitro incubation did not impact tear antimicrobial activity. Conclusions This study shows that post lens tear fluid can lose antimicrobial activity over time during contact lens wear, supporting the idea that efficient tear exchange under a lens is critical for homeostasis. Additional studies are needed to determine applicability to other lens types, wearing modalities, and relevance to contact lens-related infections. PMID:25955639

  10. Determination of absorbed dose to the lens of eye from external sources

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-01-01

    The methods of determining absorbed dose distributions in human eyeball by means of the experiments and available theories have been reported. A water phantom was built up. The distributions of beta dose were measured by an extrapolation ionization chamber at some depths corresponding to components of human eyeball such as cornea, sclera, anterior chamber and the lens of eye. The ratios among superficial absorbed dose (at 0.07 mm) and average absorbed doses at the depths 1,2,3 mm are obtained. They can be used for confining the deterministic effects of superficial tissues and organs such as the lens of eye for weakly penetrating radiations

  11. ALLOGENEIC TRANSPLANTATION FOR CHRONIC LYMPHOCYTIC LEUKEMIA

    Directory of Open Access Journals (Sweden)

    Patrizia Chiusolo

    2010-05-01

    Full Text Available

    Even if Chronic lymphocytic leukemia (CLL often has an indolent behavior with good responsiveness to cytoreductive treatment, about 20% of the patients, so called "poor-risk" patients, show an aggressive course and die within a few years despite early intensive therapies. Criteria for poor-risk disease according to the European Bone Marrow Transplantation (EBMT CLL Transplant Consensus are: purine analogue refractoriness, early relapse after purine analogue combination therapy, CLL with p53 lesion requiring treatment.

    Allogeneic transplant has potential curative role in CLL, however burden with very  high transplant related mortality (TRM rates of 38-50%:

    A major advance in reducing the short-term morbidity and mortality of allogeneic stem cell transplantation (SCT has been the introduction of non-myeloablative or reduced intensity conditioning (RIC regimens to allow engraftment of allogeneic stem cells. There is no doubt that the crucial therapeutic principle of allo-SCT in CLL is graft versus leukemia (GVL activity.

    The major complications of allogeneic SCT in CLL are: chronic graft-versus-host-disease (GVHD affecting quality of life, high graft rejection and infection rates rates correlated with preexisting immunosuppression. Disease relapse remains the major cause of failure after RIC allo-HCT in CLL patients.

    Sensitive minimal residual disease (MRD quantification has strong prognostic impact after transplant.

     

  12. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  13. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    Science.gov (United States)

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. A Class I UV-Blocking (senofilcon A) Soft Contact Lens Prevents UVA-induced Yellow Fluorescence and NADH loss in the Rabbit Lens Nucleus in vivo

    Science.gov (United States)

    Giblin, Frank J.; Lin, Li-Ren; Simpanya, Mukoma F.; Leverenz, Victor R.; Fick, Catherine E.

    2012-01-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm2 on the cornea) for 1 hour using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 hour. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  15. Three-Dimensional Cataract Crystalline Lens Imaging With Swept-Source Optical Coherence Tomography.

    Science.gov (United States)

    de Castro, Alberto; Benito, Antonio; Manzanera, Silvestre; Mompeán, Juan; Cañizares, Belén; Martínez, David; Marín, Jose María; Grulkowski, Ireneusz; Artal, Pablo

    2018-02-01

    To image, describe, and characterize different features visible in the crystalline lens of older adults with and without cataract when imaged three-dimensionally with a swept-source optical coherence tomography (SS-OCT) system. We used a new SS-OCT laboratory prototype designed to enhance the visualization of the crystalline lens and imaged the entire anterior segment of both eyes in two groups of participants: patients scheduled to undergo cataract surgery, n = 17, age range 36 to 91 years old, and volunteers without visual complains, n = 14, age range 20 to 81 years old. Pre-cataract surgery patients were also clinically graded according to the Lens Opacification Classification System III. The three-dimensional location and shape of the visible opacities were compared with the clinical grading. Hypo- and hyperreflective features were visible in the lens of all pre-cataract surgery patients and in some of the older adults in the volunteer group. When the clinical examination revealed cortical or subcapsular cataracts, hyperreflective features were visible either in the cortex parallel to the surfaces of the lens or in the posterior pole. Other type of opacities that appeared as hyporeflective localized features were identified in the cortex of the lens. The OCT signal in the nucleus of the crystalline lens correlated with the nuclear cataract clinical grade. A dedicated OCT is a useful tool to study in vivo the subtle opacities in the cataractous crystalline lens, revealing its position and size three-dimensionally. The use of these images allows obtaining more detailed information on the age-related changes leading to cataract.

  16. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    Science.gov (United States)

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  17. Clinical features of secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation

    Directory of Open Access Journals (Sweden)

    Yi Ma

    2018-04-01

    Full Text Available AIM: To investigate the clinical characteristics of secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation, and to analyze the influence of operation on visual acuity and intraocular pressure(IOP. METHODS: Totally 38 cases(38 eyesof the secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation in ophthalmology department of our hospital from December 2014 to December 2016 were enrolled and their medical records were analyzed retrospectively to observe the clinical characteristics of glaucoma. Preoperative mydriasis was carried out and surgical methods were chosen according to the lenses location and extent of suspensory ligament. Preoperative and postoperative anterior chamber depth, corneal endothelial cell density, IOP, visual field, visual acuity and complications were analyzed. RESULTS: The average intraocular pressure was 18.17±1.43mmHg at postoperatively 10d, which was significantly lower than 38.77±2.45mmHg before operation, the difference had statistical significance(PP>0.05. The postoperative anterior chamber depth was 2.45±0.44mm, which was significantly higher than 1.23±0.35mm before operation, the difference had statistical significance(P2 and decreased significantly, compared with 1735.32±340.32/mm2 before operation, the difference had statistical significance(PCONCLUSION: Clinical symptoms and signs of secondary glaucoma in patients with lens suspensory ligament laxity or occult subluxation are more complex, which needs to be distinguished with other types of glaucoma in clinical treatment, and its surgical methods shall be chosen according to different suspensory ligament site and lens subluxation scope.

  18. A new method of prefabricated vascularized allogenic bone grafts for maxillo-mandibular reconstruction

    International Nuclear Information System (INIS)

    Pill-Hoon Choung

    1999-01-01

    Although there are various applications of allogenic bone grafts, a new technique of prevascularized lyophilized allogenic bone grafting for maxillo-mandibular reconstruction will be presented. Allogenic bone has been made by author's protocol for jaw defects as a powder, chip or block bone type. The author used lyophilized allogenic bone grafts for discontinuity defects as a block bone. In those cases, neovascularization and resorption of the allogenic bone were important factors for success of grafting. To overcome the problems, the author designed the technique of prefabricated vascularization of allogenic bone, which was lyophilized cranium, with an application of bovine BMP or not. Lyophilized cranial bone was designed for the defects and was put into the scalp. After confirming a hot spot via scintigram several months later, vascularized allogenic bone was harvested pedicled on the parietotemporal fascia based on the superficial temporal artery and vein. Vascularized allogenic cranial bone was rotated into the defect and fixed rigidly. Postoperatively, there was no severe resorption and functional disturbance of the mandible. In this technique, BMP seems to be an important role to help osteogenesis and neovascularization. Eight patients underwent prefabricated vascularization of allogenic bone grafts. Among them, four cases of reconstruction in mandibular discontinuity defects and one case of reconstruction in maxillectomy defect underwent this method, which will be presented with good results. This method may be an alternative technique of microvascular free bone graft

  19. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant

    Directory of Open Access Journals (Sweden)

    Clara Ye

    2018-06-01

    Full Text Available Purpose: We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL (Visian ICL™, Staar Inc., Monrovia, CA implant that resulted in advanced visual field loss. Observations: A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Conclusions and importance: Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss. Keywords: Phakic intraocular lens, Intraocular collamer lens, Pigment dispersion, Glaucoma

  20. A class I (Senofilcon A) soft contact lens prevents UVB-induced ocular effects, including cataract, in the rabbit in vivo.

    Science.gov (United States)

    Giblin, Frank J; Lin, Li-Ren; Leverenz, Victor R; Dang, Loan

    2011-06-01

    UVB radiation from sunlight is known to be a risk factor for human cataract. The purpose in this study was to investigate the ability of a class I UV-blocking soft contact lens to protect against UVB-induced effects on the ocular tissues of the rabbit in vivo. Eyes of rabbits were exposed to UVB light for 30 minutes (270-360 nm, peak at 310 nm, 1.7 mW/cm(2) on the cornea). Eyes were irradiated in the presence of either a UV-blocking senofilcon A contact lens, a minimally UV-blocking lotrafilcon A contact lens, or no contact lens at all. Effects on the cornea and lens were evaluated at various times after exposure. Eyes irradiated with no contact lens protection showed corneal epithelial cell loss plus lens epithelial cell swelling, vacuole formation, and DNA single-strand breaks, as well as lens anterior subcapsular opacification. The senofilcon A lens protected nearly completely against the UVB-induced effects, whereas the lotrafilcon A lens showed no protection. The results indicate that use of a senofilcon A contact lens is beneficial in protecting ocular tissues of the rabbit against the harmful effects of UVB light, including photokeratitis and cataract.

  1. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  2. Spontaneous, late, in-the-bag intraocular lens subluxation in a patient with a previous acute angle-closure glaucoma attack.

    Science.gov (United States)

    Su, Wei-Wen; Chang, Shirley H L

    2004-08-01

    Cataract surgery was performed in a 49-year-old woman 16 months after an acute angle-closure glaucoma attack. Zonular dialysis was observed during surgery, but the intraocular lens (IOL) was implanted in the capsular bag uneventfully. At 4 1/2 months, 1 IOL loop wrapped in the bag herniated into the anterior chamber. The patient had no history of trauma. The IOL loop remained in the anterior chamber for 9 months, until the subluxated IOL spontaneously returned to its original position. Six months later, the IOL again dislocated into the anterior chamber.

  3. Crystalline lens dislocation secondary to bacterial endogenous endophthalmitis.

    Science.gov (United States)

    Sangave, Amit; Komati, Rahul; Weinmann, Allison; Samuel, Linoj; Desai, Uday

    2017-09-01

    To present an unusual case of endogenous endophthalmitis secondary to Group A streptococcus (GAS) that resulted in dislocation of the crystalline lens. An immunocompetent 51-year-old man presented to the emergency room (ER) with upper respiratory infection (URI) symptoms and painful right eye. He was diagnosed with URI and viral conjunctivitis and discharged on oral azithromycin and polytrim eyedrops. He returned to the ER 30 h later with sepsis and findings consistent with endophthalmitis, including light perception only vision. Ophthalmology was consulted at this time and an emergent vitreous tap and injection was performed. Both blood and vitreous cultures grew an atypical non-hemolytic variant of GAS ( Streptococcus pyogenes ). The primary source of infection was presumed to be secondary to pharyngitis or cutaneous dissemination. Final vision in the affected eye was no light perception, likely from a combination of anterior segment scarring, posterior segment damage, and hypotony. Interestingly, head computed tomography (CT) at the initial ER presentation showed normal lens position, but repeat CT at re-presentation revealed posterior dislocation of the lens. Endophthalmitis secondary to GAS has been sparsely reported in the literature, and this case highlights a unique clinical presentation. We suspect that this atypical non-hemolytic strain may have evaded detection on initial pharyngeal cultures. Additionally, we hypothesize that GAS-mediated protease release resulted in breakdown of the zonular fibers and subsequent lens dislocation. Ophthalmologists should be aware of GAS and its devastating intraocular manifestations.

  4. Annular and central heavy pigment deposition on the posterior lens capsule in the pigment dispersion syndrome: pigment deposition on the posterior lens capsule in the pigment dispersion syndrome.

    Science.gov (United States)

    Turgut, Burak; Türkçüoğlu, Peykan; Deniz, Nurettin; Catak, Onur

    2008-12-01

    To report annular and central heavy pigment deposition on the posterior lens capsule in a case of pigment dispersion syndrome. Case report. A 36-year-old female with bilateral pigment dispersion syndrome presented with progressive decrease in visual acuity in the right eye over the past 1-2 years. Clinical examination revealed the typical findings of pigment dispersion syndrome including bilateral Krunkenberg spindles, iris transillumination defects, and dense trabecular meshwork pigmentation. Remarkably, annular and central dense pigmentation of the posterior lens capsule was noted in the right eye. Annular pigment deposition on the posterior lens capsule may be a rare finding associated with pigment dispersion syndrome. Such a finding suggests that there may be aqueous flow into the retrolental space in some patients with this condition. The way of central pigmentation is the entrance of aqueous to Berger's space. In our case, it is probable that spontaneous detachment of the anterior hyaloid membrane aided this entrance.

  5. DNA methyl transferases are differentially expressed in the human anterior eye segment.

    Science.gov (United States)

    Bonnin, Nicolas; Belville, Corinne; Chiambaretta, Frédéric; Sapin, Vincent; Blanchon, Loïc

    2014-08-01

    DNA methylation is an epigenetic mark involved in the control of genes expression. Abnormal epigenetic events have been reported in human pathologies but weakly documented in eye diseases. The purpose of this study was to establish DNMT mRNA and protein expression levels in the anterior eye segment tissues and their related (primary or immortalized) cell cultures as a first step towards future in vivo and in vitro methylomic studies. Total mRNA was extracted from human cornea, conjunctiva, anterior lens capsule, trabeculum and related cell cultures (cornea epithelial, trabecular meshwork, keratocytes for primary cells; and HCE, Chang, B-3 for immortalized cells). cDNA was quantified by real-time PCR using specific primers for DNMT1, 2, 3A, 3B and 3L. Immunolocalization assays were carried out on human cornea using specific primary antibodies for DNMT1, 2 and 3A, 3B and 3L. All DNMT transcripts were detected in human cornea, conjunctiva, anterior lens capsule, trabeculum and related cells but showed statistically different expression patterns between tissues and cells. DNMT2 protein presented a specific and singular expression pattern in corneal endothelium. This study produced the first inventory of the expression patterns of DNMTs in human adult anterior eye segment. Our research highlights that DNA methylation cannot be ruled out as a way to bring new insights into well-known ocular diseases. In addition, future DNA methylation studies using various cells as experimental models need to be conducted with attention to approach the results analysis from a global tissue perspective. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-06-01

    Full Text Available Mun Yueh Faria,1 Nuno Ferreira,2 Eliana Neto,1 1Vitreo Retinal Department, 2Ophthalmology Department, Santa Maria Hospital, Lisbon, Portugal Objective: To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL in ectopia lentis in Marfan syndrome (MFS. Design: Retrospective study. Methods: Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA, and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years. Results: The average follow-up period was 6.66 months (range: 4–16 months. Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was –0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg and 16 mmHg (range: 12–18 mmHg, respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm, as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion: Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that

  7. Expression of antigens coded in murine leukemia viruses on thymocytes of allogeneic donor origin in AKR mice following syngeneic or allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Wustrow, T.P.; Good, R.A.

    1985-01-01

    Removal of T-lymphocytes from marrow inoculum with monoclonal antibody plus complement permitted establishment of long-lived allogeneic chimeras between C57BL/6 and AKR/J mice. Development of leukemia was prevented for 15 mo. Protection from leukemia occurred with both young (4 wk) and older (4 mo) recipients. AKR mice reconstituted with syngeneic marrow or control AKR mice all developed leukemia-lymphoma before 1 yr of age. During spontaneous lymphomagenesis in AKR mice, amplified expression of gag or env gene-coded virus antigens on the surface of thymocytes preceded leukemia development and evidence for amplification of other virus genes. These changes generally appeared before 6 mo. Similar viral gene expression and viral gene amplification occurred in the thymus and spleen cells of leukemia-resistant chimeric mice. Using monoclonal antibodies to Mr 70,000 glycoprotein epitopes characteristic of ecotropic, xenotropic, or dualtropic viruses, antigens marking each virus form were found on thymocytes of allogeneic 4-wk and 4-mo chimeras as well as on the cells of AKR mice and of AKR mice reconstituted with syngeneic marrow. Flow cytometric analysis showed amplification of the virus genes in mice protected from leukemia-lymphoma by allogeneic bone marrow transplantation from leukemia-resistant mice. Allogeneic chimeras and syngeneically transplanted mice both showed evidence of accelerated viremia and of recombinant virus formation. The findings suggest that an event essential to leukemogenesis which occurs within the AKR lymphoid cells or their environment is lacking in the allogeneic chimeras. The nature of this influence of a resistance gene or genes introduced into AKR mice by allogeneic bone marrow transplantation deserves further study

  8. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  9. TUG1 promotes lens epithelial cell apoptosis by regulating miR-421/caspase-3 axis in age-related cataract.

    Science.gov (United States)

    Li, Guoxing; Song, Huiyang; Chen, Lei; Yang, Weihua; Nan, Kaihui; Lu, Peirong

    2017-07-01

    Age-related cataract is among the most common chronic disorders of ageing and the apoptosis of lens epithelial cells contributes to non-congenital cataract development. We amid to explore the role of TUG1 and miR-421 in the age-related cataract. The expression level of TUG1, miR-421 and caspase-3 were detected by RT-qPCR. The apoptotic-related protein, caspase-3, Bax and blc-2 were analyzed by western blot. We performed ultraviolet (UV) irradiation to induce SAR01/04 cell apoptosis which was analyzed by flow cytometry. RIP pull-down and luciferase reporter assay were used to verified the combination and regulating among TUG1, miR-421 and caspase-3. Here, we observed that the expression level of TUG1 and caspase-3 in the anterior lens capsules of age-related cataract were significantly higher and miR-421 was significantly lower than that in the normal anterior lens capsules. The apoptosis-related protein, caspase-3, Bax and blc-2 were abnormal expression in the anterior lens capsules of age-related cataract tissue. Our data showed that the expression level of TUG1 and caspase-3 and cell apoptosis rate in SAR01/04 cells treated with UV irradiation was remarkably higher than that in the control. TUG1 negatively regulated miR-421 expression and promoted UV irradiation-induced SAR01/04 cell apoptosis. However, miR-421 inhibitor and pcDNA-caspase-3 could reverse the action of the SRA01/04 cell apoptosis by si-TUG1, which suggested TUG1 promoted UV irradiation-induced apoptosis through downregulating miR-421 expression. Furthermore, this study confirmed TUG1 could been in combination with miR-421, and TUG1 and caspase-3 were both a directly target of miR-421. TUG1 modulated lens epithelial cell apoptosis through miR-421/caspase-3 axis. These findings will offer a novel insight into the pathogenesis of cataract. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Growth and optical development of the ocular lens of the squid (Sepioteuthis lessoniana).

    Science.gov (United States)

    Sivak, J G; West, J A; Campbell, M C

    1994-09-01

    Lens focal properties (spherical aberration), diameter and relative anterior/posterior proportions were measured photographically for Japanese squid (Sepioteuthis lessoniana) at ages 4-6 weeks, 7-9 weeks and 7-8 months. The measures involved photographing the refractive effects of lenses in a physiological solution, with and without an index matching fluid (polyvinylpyrroloidone solution), on a parallel array of fine helium-neon laser beams. Spherical aberration was determined from measurement of back vertex distance. Similar measurements were made on lenses from the eyes of cuttlefish (Sepia officinalis). The cephalopod lens develops as hemispheric halves from separate ectodermal sources. The posterior component contributes, on average, about 60% of axial lens diameter in S. lessoniana of all ages and 55% in S. officinalis. However, these proportions vary widely in both species. All lenses of both species show that spherical aberration is neutralized, although small variations in back vertex distance (positive and negative spherical aberration) were measured. Preliminary measures indicate that the refractive index distribution within the cephalopod lens varies in a manner reminiscent of teleost lenses. Squid lenses from animals 7-9 weeks of age were optimally corrected for spherical aberration. Some squid of this age, from a separate tank, showed a high incidence of cataract development. In each case, lens opacification was caused by deterioration of the posterior lens component.

  11. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

    Science.gov (United States)

    Kawamorita, Takushi; Uozato, Hiroshi; Shimizu, Kimiya

    2012-06-01

    A modified implantable collamer lens (ICL) with a central hole (diameter, 0.36 mm), a "Hole-ICL", was created to improve aqueous humour circulation. The aim of this study was to investigate the fluid dynamic characteristics of aqueous humour in a Hole-ICL using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V5 (Mentor Graphics Corp.). For the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. Both ICLs were -9.0 diopters (D) and 12.0 mm in length, with an optic of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μl/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated, and trajectory analysis was performed. The flow velocity 0.25 mm in front of the centre of the crystalline lens was 1.52 × 10(-1) mm/sec for the Hole-ICL and 1.21 × 10(-5) mm/sec for the conventional ICL. Outward flow from the hole in the Hole-ICL was confirmed by trajectory analysis. These results suggest that Hole-ICLs improve the circulation of aqueous humour to the anterior surface of the crystalline lens.

  12. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  13. A Class I UV-blocking (senofilcon A) soft contact lens prevents UVA-induced yellow fluorescence and NADH loss in the rabbit lens nucleus in vivo.

    Science.gov (United States)

    Giblin, Frank J; Lin, Li-Ren; Simpanya, Mukoma F; Leverenz, Victor R; Fick, Catherine E

    2012-09-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm(2) on the cornea) for 1 h using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 h. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  14. Supracapsular glued intraocular lens in progressive subluxated cataracts: Technique to retain an intact vitreous face.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Mazzotta, Cosimo; Rechichi, Miguel; Agarwal, Athiya

    2017-03-01

    We describe a technique to prevent late intraocular lens (IOL) subluxation and dislocation that can be associated with progressive zonulopathy. Supracapsular glued IOL fixation is done to retain an intact anterior hyaloid face and avoid vitreous disturbance while providing stable long-term IOL fixation. Phacoemulsification is followed by glued IOL implantation above intact anterior and posterior capsules. Sclerotomies are created ab interno in a supracapsular plane under diametrically opposite lamellar scleral flaps without entering the vitreous cavity. Haptics are externalized in the supracapsular plane and tucked into intrascleral tunnels. Intraoperative or postoperative posterior capsulorhexis or capsulotomy and anterior capsule relaxing cuts can prevent capsule phimosis. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Safety and effect of femtosecond laser-assisted cataract surgery combined with Cionni capsular tension ring implantation in the management of traumatic lens subluxation

    Directory of Open Access Journals (Sweden)

    Jia-Hui Chen

    2017-07-01

    Full Text Available AIM:To investigate the safety and effect of femtosecond laser-assisted cataract surgery with Cionni modified capsular tension ring(MCTRimplantation in the management of traumatic lens subluxation.METHODS: Totally 11 patients(11 eyeswith traumatic lens subluxation were divided into three groups according to the severity of lens dislocation, ranging from 90° to 120°(4 eyes, 120° to 180°(5 eyesand 180° to 270°(2 eyes. The contact LenSx femtosecond laser cataract surgery platform was applied to create the capsulotomy, prepare nuclear fragmentation and make corneal wound creation. Anterior vitrectomy was performed in some patients during the surgery. After capsular retractors insertion and phacoemulsification, the MCTR was inserted to the capsular bag and fixed to the sclera. Finally, the IOL was implanted into the capsular bag. Postoperative visual acuity, intra- and post-operative complications, anterior capsular opening, IOL and MCTR position and intraocular pressure(IOPwere assessed.RESULTS:The duration of follow-up was 2mo. All the operations were completed successfully. Five eyes underwent cataract surgery combined with anterior vitrectomy. Four eyes had been inserted with 2-eyelet MCTR and seven eyes with 1-eyelet MCTR. The best corrected visual acuity(BCVAafter operation was better than 0.5 in 4 eyes, between 0.3 and 0.5 in 3 eyes, between 0.1 and 0.3 in 3 eyes, and less than 0.1 in 1 eye. Compared with preoperative BCVA, the difference was statistically significant(PCONCLUSION:Femtosecond laser-assisted cataract surgery can improve the success rate of capsulorhexis, and reduce the difficulty of nuclear fragmentation. Femtosecond laser-assisted cataract surgery combined with MCTR implantation is an ideal surgical method for traumatic lens subluxation.

  16. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  17. Effects of hyperbaric oxygen on crystalline lens and retina in nicotine-exposed rats.

    Science.gov (United States)

    Ari, Seyhmus; Nergiz, Yusuf; Cingü, Abdullah Kürşat; Atay, Ahmet Engin; Sahin, Alparslan; Cinar, Yasin; Caca, Ihsan

    2013-03-01

    To determine histopathological changes on crystalline lens and retina of rats after subcutaneous injection of nicotine and to examine the effects of hyperbaric oxygen (HBO) on these changes related to nicotine exposure. Twenty-eight female Sprague-Dawley rats were enrolled in the study and the rats were divided into four equal sized groups randomly (Group N: the rats exposed only to nicotine, group HB: the rats received only HBO, group N+HB: the rats that underwent to nicotine injection and subsequently received HBO, group C: the control group that neither exposed to nicotine nor received HBO). The rats were sacrificed by decapitation method and all were enucleated immediately after scarification. Tissue samples from crystalline lens, lens capsule, and the retina from the right eyes of the rats were examined by light microscopy. While the histological appearances of the retina and the lens was similar in group HB, group N+HB, and the control group; group N showed some pathological changes like decrement in the retinal ganglion cell density, atrophy of the retinal nerve fiber layer, congestion of the vessels in the optic nerve head, thinning of the internal plexiform layer, thinning of the lens capsule, and transformation of the anterior subcapsular epithelium into squamous epithelia. Subcutaneous injection of nicotine was found to be related with some pathological changes in the retina and lens of the Sprague-Dawley rats. However HBO caused no significant negative effect. Furthermore, the histopathological changes related to nicotine exposure in the lens and retina of the rats recovered by the application of HBO.

  18. Evaluation of Artisan aphakic intraocular lens in cases of pediatric aphakia with insufficient capsular support.

    Science.gov (United States)

    Gawdat, Ghada I; Taher, Sameh G; Salama, Marwa M; Ali, Adel A

    2015-06-01

    To evaluate the visual outcomes and complications after Artisan iris-claw lens implantation in aphakic children with insufficient capsular support. In this prospective, interventional noncontrolled study, aphakic eyes of consecutive patients >2 years of age with insufficient capsular support who underwent Artisan intraocular lens (IOL) implantation between June 2011 and December 2012 were followed for 1 year. Patients with anterior chamber depth IOL were included, 18 eyes with subluxated lens and 7 following trauma. The mean preoperative logMAR best-corrected visual acuity for traumatic aphakic patients was 0.95 ± 0.36; for patients with subluxation, 0.7 ± 0.26. Values improved at 1 year to 0.38 ± 0.15 (P IOL implantation for pediatric aphakia achieved a good visual outcome. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  19. [fs-Lentotomy: presbyopia reversal by generating gliding planes inside the crystalline lens].

    Science.gov (United States)

    Lubatschowski, H; Schumacher, S; Wegener, A; Fromm, M; Oberheide, U; Hoffmann, H; Gerten, G

    2009-12-01

    Based on the Helmholtz theory for accommodation, increasing sclerosis of the lens nucleus and cortex is the main cause for the development of presbyopia. Existing therapies, however, do not reverse the stiffness of the crystalline lens and thus do not regain real accommodation ability. A new approach to restore the flexibility of the lens has been realised by utilising the non-linear interaction of ultrafast laser pulses with transparent tissue, the so-called photodisruption. This process has been used to create micro-incisions which act as gliding planes inside the crystalline lens without opening the eye globe. This treatment method, known as fs-lentotomy, enables regeneration of real dynamic accommodation. For the first time, 3D structures for gliding planes were successfully generated in experiments with human donor lenses of different ages. An average increase in anterior-posterior lens thickness of 100 mum accompanied by a decrease of equatorial lens diameter was observed as a direct consequence of fs-lentotomy. This is attributed to the increased flexibility, as the force of the capsule bag moulds the lens tissue more spherically. Moreover, in vivo experiments on rabbit eye lenses did not induce an increasing opacification (cataract) over a six-month follow-up period. However, the incisions were still detectable using Scheimpflug imaging and histopathological techniques, although the visibility of the incisions was declining. Furthermore, no side effects were observed during the wound healing process and during a six-months follow-up period. Based on these findings fs-lentotomy might have the potential to become a procedure for the reversal of presbyopia. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  20. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division

  1. Ready-made allogeneic ABO-specific serum eye drops

    DEFF Research Database (Denmark)

    Harritshøj, Lene Holm; Nielsen, Connie; Ullum, Henrik

    2014-01-01

    serum treatment. CONCLUSION: Ready-made ABO-identical allogeneic serum eye drops were straightforwardly produced, quality-assured and registered as a safe standard blood product for the treatment of certain cases of severe dry eye disease. Therapeutic efficacy was comparable to previous reports......PURPOSE: To overcome problems and delays of the preparation of autologous serum eye drops, a production line of ABO-specific allogeneic serum eye drops from male blood donors was set up in a blood bank. Feasibility, clinical routine, safety and efficacy were evaluated in a cohort of patients...

  2. Allogeneic tumor cell vaccines: the promise and limitations in clinical trials.

    Science.gov (United States)

    Srivatsan, Sanjay; Patel, Jaina M; Bozeman, Erica N; Imasuen, Imade E; He, Sara; Daniels, Danielle; Selvaraj, Periasamy

    2014-01-01

    The high mortality rate associated with cancer and its resistance to conventional treatments such as radiation and chemotherapy has led to the investigation of a variety of anti-cancer immunotherapies. The development of novel immunotherapies has been bolstered by the discovery of tumor-associated antigens (TAAs), through gene sequencing and proteomics. One such immunotherapy employs established allogeneic human cancer cell lines to induce antitumor immunity in patients through TAA presentation. Allogeneic cancer immunotherapies are desirable in a clinical setting due to their ease of production and availability. This review aims to summarize clinical trials of allogeneic tumor immunotherapies in various cancer types. To date, clinical trials have shown limited success due potentially to extensive degrees of inter- and intra-tumoral heterogeneity found among cancer patients. However, these clinical results provide guidance for the rational design and creation of more effective allogeneic tumor immunotherapies for use as monotherapies or in combination with other therapies.

  3. Pharmacokinetics of Caffeine in the Lens Capsule/Epithelium After Peroral Intake: A Pilot Randomized Controlled Study.

    Science.gov (United States)

    Kronschläger, Martin; Stimpfl, Thomas; Ruiß, Manuel; Hirnschall, Nino; Leisser, Christoph; Findl, Oliver

    2018-04-01

    To determine the pharmacokinetics of perorally administered caffeine, a widely consumed and potent dietary antioxidant, in the anterior lens capsule and lens epithelial cells, a crucial cell monolayer for cataract development. Bilateral cataract patients were scheduled for cataract surgery with a caffeine abstinence of 1 week before surgery of each eye. At the day of surgery of the second eye patients were administered no drink (0-mg group) or coffee with 60-, 120-, or 180-mg caffeine. After capsulorhexis the lens capsule including lens epithelial cells was transferred to a test tube for analysis of caffeine concentration by gas chromatography-mass spectrometry (GC-MS/MS). Coffee consumption significantly (P < 0.05) increased caffeine levels of the lens capsule/epithelium in the 60-, 120-, and 180-mg group. Caffeine concentrations (caffeine ng/lens capsule/epithelium) measured as difference between 1st and 2nd eye were -0.52 ± 1.16 (0-mg group, n = 7), 1.88 ± 2.02 (60-mg group, n = 8), 2.09 ± 0.67 (120-mg group, n = 9), and 3.68 ± 1.86 (180-mg group, n = 9). The increase constant of caffeine in a linear regression model was estimated as a 95% CI 0.02 ± 0.0046 (degrees of freedom; 25; r = 0.85). Peroral intake of coffee significantly increased caffeine concentrations in the lens capsule and lens epithelial cells in a dose-dependent manner. This information is important for further investigations on preventing cataract.

  4. Unilateral anterior uveitis complicating zoledronic acid therapy in breast cancer

    Directory of Open Access Journals (Sweden)

    El Saghir Nagi S

    2005-12-01

    Full Text Available Abstract Background Zoledronic acid is very widely used in patients with metastatic bone disease and osteoporosis. Only one case of bilateral uveitis was recently reported related to its use. Case presentation We report the first case of severe unilateral anterior uveitis in a patient with breast cancer and an intraocular lens. Following zoledronic acid infusion, the patient developed severe and dramatic right eye pain with decreased visual acuity within 24 hours and was found to have a fibrinous anterior uveitis of moderate severity The patient was treated with topical prednisone and atropine eyedrops and recovered slowly over several months. Conclusion Internists, oncologists, endocrinologists, and ophtalmologists should be aware of uveitis as a possible complication of zoledronic acid therapy. Patients should be instructed to report immediately to their physicians and treatment with topical prednisone and atropine eyedrops should be instituted immediately at the onset of symptoms. This report documents anterior uveitis as a complication of zoledronic acid therapy. This reaction could be an idiosyncratic one but further research may shed more light on the etiology.

  5. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  6. The Role of Type IV Collagen in Developing Lens in Mouse Fetuses

    Directory of Open Access Journals (Sweden)

    Mehdi Jalali

    2009-09-01

    Full Text Available Objective(sExtracellular matrix (ECM and basement membrane (BM play important roles in many developmental processes during development and after birth. Among the components of the BM, collagen fibers specially type IV are the most important parts. The aim of this study was to determine the time when collagen type IV appears in the BM of lens structure during mouse embryonic development.Materials and MethodsIn this experimental study, 22 female Balb/C mice were randomly selected and were kept under normal condition, finding vaginal plug was assumed as day zero of pregnancy. From embryonic day 10 to 20, all specimens were sacrificed by cervical dislocation and their heads were fixed, serially sectioned and immunohistochemistry study for tracing collagen type IV in lens were carried out.ResultsOur data revealed that collagen type IV appeared at the early stage of gestation day 12 in BM of anterior epithelial lens cells and the amount of this protein gradually increased until days 15-17 in ECM and posterior capsule epithelium. After this period, severe reaction was not observed in any part of the lens.ConclusionThese findings establish the important role of collagen IV in developing optic cup and any changes during critical period of pregnancy may be result in severe visual system defect

  7. [Alternatives to allogenous blood transfusion].

    Science.gov (United States)

    Cernea, Daniela; Vlădoianu, Alice; Stoica, Maria; Novac, M; Berteanu, Cristina

    2009-01-01

    Blood transfusion is usually meant to lower morbidity and mortality rates. Allogenous blood transfusion implies certain risks that can be avoided by autologous blood transfusions techniques including: preoperatory autologous blood donation, acute normovolemic hemodilution, intraoperatory and postoperatory blood salvage. Preoperatory blood donation and acute normovolemic hemodilution are used for planned interventions with an estimated blood loss higher than 20% of blood volume. These methods imply Erythropoietin and iron treatment. Intraoperatory and postoperatory blood salvage is performed by personnel trained in blood donation, handling and storage. Autologous blood transfusions are used for certain surgical procedures that commonly require transfusions: orthopedic surgery, radical prostatectomy, cardiovascular surgery, organ transplantation. An alternative to allogenous blood transfusion is the use of artificial oxygen transporters: human or animal hemoglobin solutions or pefluorocarbonate solutions. These solutions do not require cross reactions, do not carry diseases and are generally well tolerated and easily stored in the operating room, ambulance and other transport means. They have however a slight degree of toxicity.

  8. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  9. Allogeneic Peripheral Blood Stem Cell Harvest

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Allogeneic Peripheral Blood Stem Cell Harvest. Mobilization protocol. G-CSF 10 mcg/Kg / day for 5 days. Pheresis. Cobe Spectra; Haemonetics mcs+. Enumeration. CD34 counts; Cfu-GM assays.

  10. The Relationship between Anterior Chamber Depth, Axial Length and Intraocular Lens Power among Candidates for Cataract Surgery.

    Science.gov (United States)

    Sedaghat, Mohammad Reza; Azimi, Ali; Arasteh, Peyman; Tehranian, Naghmeh; Bamdad, Shahram

    2016-10-01

    Basic anatomical parameters in ophthalmology are variable in different countries according to ethnic groups, genetics and some environmental factors. The aim of this study was to determine the relationship between axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOL) in a referral center from eastern Iran among patients who had cataract surgery, in comparison to studies from other regions of the world. In a cross-sectional retrospective study from 2011 to 2013, the records of 698 cataract patients referring to Khatam Al Anbia general hospital in Mashhad, Iran were evaluated. We divided patients, based on their AL and ACD, into three separate groups and compared their results. The SPSS software was used for data analysis. The Chi-Square test and the Independent-samples t-test were used to compare qualitative and quantitative data between two groups, respectively. The Kendall and the Pearson product-moment correlation tests were used to assess the relationship between AL and ACD. The linear Regression model was used to obtain a mathematical model to estimate ACD, using AL, age and sex. Among individuals who had normal AL (between 22-24.5mm), there was a positive correlation between AL and ACD (p24.5mm), no significant correlation was detected. We also found that older people have shorter AL (p=0.001 and r=-0.287). Men have an average longer AL (23.7±2.4mm vs. 22.9±2.1mm; pworld and although some anatomical variations may exist regarding ophthalmic anatomy, factors like race and geographical area have little effect on the relationship between ACD, AL and IOL power calculation, furthermore our results support the use of third and fourth generation formulas for IOL power calculation.

  11. Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: Optical performance and clinical outcomes

    Directory of Open Access Journals (Sweden)

    Javier Tomás-Juan

    2015-04-01

    Full Text Available Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients’ satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material.

  12. Platelet-rich-plasmapheresis for minimising peri-operative allogeneic blood transfusion.

    Science.gov (United States)

    Carless, Paul A; Rubens, Fraser D; Anthony, Danielle M; O'Connell, Dianne; Henry, David A

    2011-03-16

    Concerns regarding the safety of transfused blood have generated considerable enthusiasm for the use of technologies intended to reduce the use of allogeneic blood (blood from an unrelated donor). Platelet-rich plasmapheresis (PRP) offers an alternative approach to blood conservation. To examine the evidence for the efficacy of PRP in reducing peri-operative allogeneic red blood cell (RBC) transfusion, and the evidence for any effect on clinical outcomes such as mortality and re-operation rates. We identified studies by searching MEDLINE (1950 to 2009), EMBASE (1980 to 2009), The Cochrane Library (Issue 1, 2009), the Internet (to March 2009) and the reference lists of published articles, reports, and reviews. Controlled parallel group trials in which adult patients, scheduled for non-urgent surgery, were randomised to PRP, or to a control group which did not receive the intervention. Primary outcomes measured were: the number of patients exposed to allogeneic RBC transfusion, and the amount of RBC transfused. Other outcomes measured were: the number of patients exposed to allogeneic platelet transfusions, fresh frozen plasma, and cryoprecipitate, blood loss, re-operation for bleeding, post-operative complications (thrombosis), mortality, and length of hospital stay. Treatment effects were pooled using a random-effects model. Trial quality was assessed using criteria proposed by Schulz et al (Schulz 1995). Twenty-two trials of PRP were identified that reported data for the number of patients exposed to allogeneic RBC transfusion. These trials evaluated a total of 1589 patients. The relative risk (RR) of exposure to allogeneic blood transfusion in those patients randomised to PRP was 0.73 (95%CI 0.59 to 0.90), equating to a relative risk reduction (RRR) of 27% and a risk difference (RD) of 19% (95%CI 10% to 29%). However, significant heterogeneity of treatment effect was observed (p transfused (weighted mean difference [WMD] -0.69, 95%CI -1.93 to 0.56 units). Trials

  13. Antioxidant status of dog aqueous humor after extracapsular lens extraction

    Directory of Open Access Journals (Sweden)

    Barros P.S.M.

    2003-01-01

    Full Text Available We determined the antioxidant status of the aqueous humor after extracapsular lens extraction in 14 mongrel dogs weighing about 10 kg. The animals were examined by slit lamp biomicroscopy, applanation tonometry and indirect ophthalmoscopy. One eye was submitted to conventional extracapsular lens extraction and the other was used as control. Samples of aqueous humor were obtained by anterior chamber paracentesis before and at days 1, 2, 3, 7 and 15 after surgery. Total antioxidant status was determined as the capacity of aqueous humor to inhibit free radical generation by 2,2-azobis(2-amidopropane chlorine. Ascorbic acid concentration was measured by HPLC with UV detection. Protein content was determined with the biuret reagent. Statistical analysis was performed by ANOVA followed by the Tukey-Kramer test. Protein concentration increased from 0.61 to 22 mg/ml 24 h after surgery. These levels were maintained and returned to normal at day 7. Total antioxidant capacity was reduced from 50 to about 30 min until day 3 and at day 7 it was equal to control. Ascorbic acid levels were reduced from 252 to about 110 µM and then returned to control values at day 15. Considering the importance of ascorbic acid concentration in aqueous humor for the maintenance of the antioxidant status of the anterior segment of the eye, the decrease of antioxidant defenses suggests that the surgical procedures promote an oxidative stress condition in the eye.

  14. A Correlation of Thin Lens Approximation to Thick Lens Design by Using Coddington Factors in Lens Design and Manufacturing

    OpenAIRE

    FARSAKOĞLU, Ö. Faruk

    2014-01-01

    The effect of Coddington factors on aberration functions has been analysed using thin lens approximation. Minimizing spherical aberrations of singlet lenses using Coddington factors in lens design depending on lens manufacturing is discussed. Notation of lens test plate pairs used in lens manufacturing is also presented in terms of Coddington shape factors.

  15. Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

    Science.gov (United States)

    Dong, Jing; Zhang, Yaqin; Zhang, Haining; Jia, Zhijie; Zhang, Suhua; Wang, Xiaogang

    2018-01-01

    To compare the axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOLP) of IOLMaster and Ultrasound in normal, long and short eyes. Seventy-four normal eyes (≥ 22 mm and ≤ 25 mm), 74 long eyes (> 25 mm) and 78 short eyes (devices in the order of IOLMaster followed by Ultrasound. The IOLP were calculated using a free online LADAS IOL formula calculator. The difference in AL and IOLP between IOLMaster and Ultrasound was statistically significant when all three groups were combined. The difference in ACD between IOLMaster and Ultrasound was statistically significant in the normal group (Peye group (Peye group (P = 0.465). For the IOLP difference between IOLMaster and Ultrasound in the normal group, the percentage of IOLP differences eye group, they were 90.5%, 5.4%, 4.1% and 0%, respectively. For the short eye group, they were 61.5%, 23.1%, 10.3%, and 5.1%, respectively. IOLMaster and Ultrasound have statistically significant differences in AL measurements and IOLP (using LADAS formula) for normal, long eye and short eye. The two instruments agree regarding ACD measurements for the long eye group, but differ for the normal and short eye groups. Moreover, the high percentage of IOLP differences greater than |0.5|D in the short eye group is noteworthy.

  16. Alternative procedures for reducing allogeneic blood transfusion in elective orthopedic surgery.

    Science.gov (United States)

    Kleinert, Kathrin; Theusinger, Oliver M; Nuernberg, Johannes; Werner, Clément M L

    2010-09-01

    Perioperative blood loss is a major problem in elective orthopedic surgery. Allogeneic transfusion is the standard treatment for perioperative blood loss resulting in low postoperative hemoglobin, but it has a number of well-recognized risks, complications, and costs. Alternatives to allogeneic blood transfusion include preoperative autologous donation and intraoperative salvage with postoperative autotransfusion. Orthopedic surgeons are often unaware of the different pre- and intraoperative possibilities of reducing blood loss and leave the management of coagulation and use of blood products completely to the anesthesiologists. The goal of this review is to compare alternatives to allogeneic blood transfusion from an orthopedic and anesthesia point of view focusing on estimated costs and acceptance by both parties.

  17. Contribution of the crystalline lens gradient refractive index to the accommodation amplitude in non-human primates: in vitro studies.

    Science.gov (United States)

    Maceo, Bianca M; Manns, Fabrice; Borja, David; Nankivil, Derek; Uhlhorn, Stephen; Arrieta, Esdras; Ho, Arthur; Augusteyn, Robert C; Parel, Jean-Marie

    2011-11-30

    The purpose of this study was to determine the contribution of the gradient refractive index to the change in lens power in hamadryas baboon and cynomolgus monkey lenses during simulated accommodation in a lens stretcher. Thirty-six monkey lenses (1.4-14.1 years) and twenty-five baboon lenses (1.8-28.0 years) were stretched in discrete steps. At each stretching step, the lens back vertex power was measured and the lens cross-section was imaged with optical coherence tomography. The radii of curvature for the lens anterior and posterior surfaces were calculated for each step. The power of each lens surface was determined using refractive indices of 1.365 for the outer cortex and 1.336 for the aqueous. The gradient contribution was calculated by subtracting the power of the surfaces from the measured lens power. In all lenses, the contribution of the surfaces and gradient increased linearly with the amplitude of accommodation. The gradient contributes on average 65 ± 3% for monkeys and 66 ± 3% for baboons to the total power change during accommodation. When expressed in percent of the total power change, the relative contribution of the gradient remains constant with accommodation and age in both species. These findings are consistent with Gullstrand's intracapsular theory of accommodation.

  18. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  19. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  20. Immunohistochemical studies of lens crystallins in the dysgenetic lens (dyl) mutant mice

    NARCIS (Netherlands)

    Brahma, S.K.; Sanyal, S.

    1984-01-01

    The lens in the dyl mutant mice shows a persistent lens-ectodermal connection as well as degeneration and extrusion of lens materials after the initial differentiation of the fibres. Immunohistochemical investigation of the ontogeny of the lens crystallins in this developing mutant lens has been

  1. Influence of Gravity on Ocular Lens Position.

    Science.gov (United States)

    Lister, Lucas J; Suheimat, Marwan; Verkicharla, Pavan K; Mallen, Edward A H; Atchison, David A

    2016-04-01

    We determined whether human ocular lens position is influenced by gravity. Anterior chamber depth (ACD) and lens thickness (LT) were determined with a Haag-Streit Lenstar LS900 for right eyes of participants in two age groups, with a young group of 13 participants aged 18 to 21 years (mean, 21 years; SD, 1 year) and an older group of 10 participants aged 50 to 63 years (mean, 58 years; SD, 4 years). There were two sessions for each participant separated by at least 48 hours, with one session for the usual upright head position and one session for a downwards head position. In a session, testing was done for minimum accommodation followed by testing at maximum accommodation. A drop of 2% pilocarpine nitrate was instilled, and testing was repeated after 30 minutes under minimum and maximum accommodation conditions. Gravity, manipulated through head posture, affected ACD for young adult and older adult groups but mean effects were only small, ranging from 0.04 to 0.12 mm, and for the older group required the instillation of an accommodation-stimulating drug. Gravity had a weakly significant effect on LT for the young group without accommodation or a drug, but the effect was small at 0.04 ± 0.06 mm (mean ± SD, P = 0.04). There is a small but real effect of gravity on crystalline lens position, manifested as reduction in ACD at high levels of accommodative effort with the head in a downwards position. This provides evidence of the ability of zonules to slacken during strong accommodation.

  2. Ethnic differences in lens parameters measured by ocular biometry in a cataract surgery population.

    Science.gov (United States)

    Wang, Dajiang; Amoozgar, Behzad; Porco, Travis; Wang, Zhen; Lin, Shan C

    2017-01-01

    To investigate whether differences exist in lens position and other lens parameters among major ethnic groups with cataractous eyes, which may help explain racial differences in angle closure risk. This retrospective, cross-sectional study included 807 adult patients who had cataract surgery between years 2014 and 2016 at the University of California, San Francisco (UCSF). Adult patients of white, Asian, Hispanic and African-American ethnicity were included. Lens position (LP), defined as anterior chamber depth (ACD) + 1/2 lens thickness (LT), was assessed using measurements from optical biometry. Other assessed biometric parameters included axial length (AL), relative lens position (RLP) (defined as LP/AL), and anterior chamber depth (ACD). A total of 807 patients and 1361 eyes were included in this study from a database of patients having cataract surgery. Mean age was 69.2 years (age range from 18 to 101 years old), and 60.3% of patients were women. The mean LP measurements were 5.54±0.32 mm for white, 5.38±0.32 mm for Asian, 5.32±0.30 mm for Hispanic, and 5.40±0.28 mm for African-American participants. After adjusting for age, sex, and AL, significant differences were found when comparing LP in paired comparisons among White cohort with Asians (P<0.001), Hispanics (P<0.001) and African-Americans (P = 0.003). Additionally, when comparing RLP, similar significant results were found when comparing Whites with Asians (P<0.001), Hispanics (P<0.001) and African-Americans (P = 0.002). Lastly, pair-wise comparison of LT between ethnic groups showed significant differences while comparing Asians with Whites (P = 0.001) and Asians with African-Americans (P<0.001). The results of this study suggest that the LP of Hispanic, Asian, and African-American patients are significantly smaller than that of White patients, and among all ethnic groups, Hispanics and after Asians have the smallest LP (P<0.001) and RLP (P<0.001). These findings may have implications for the

  3. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  4. Intraocular lens alignment from purkinje and Scheimpflug imaging.

    Science.gov (United States)

    Rosales, Patricia; De Castro, Alberto; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2010-11-01

    The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system images the reflections of an oblique collimated light source on the anterior cornea and anterior and posterior IOL surfaces and relies on the well supported assumption of the linearity of the Purkinje images with respect to IOL tilt and decentration. Scheimpflug imaging requires geometrical distortion correction and image processing techniques to retrieve the pupillary axis, IOL axis and pupil centre from the three-dimensional anterior segment image of the eye. Validation of the techniques using a physical eye model indicates that IOL tilt is estimated within an accuracy of 0.261 degree and decentration within 0.161 mm. Measurements on patients implanted with aspheric IOLs indicate that IOL tilt and decentration tend to be mirror symmetric between left and right eyes. The average tilt was 1.54 degrees and the average decentration was 0.21 mm. Simulated aberration patterns using custom models of the patients eyes, built using anatomical data of the anterior cornea and foveal position, the IOL geometry and the measured IOL tilt and decentration predict the experimental wave aberrations measured using laser ray tracing aberrometry on the same eyes. This reveals a relatively minor contribution of IOL tilt and decentration on the higher-order aberrations of the normal pseudophakic eye.

  5. Completion rates of anterior and posterior continuous curvilinear capsulorrhexis in pediatric cataract surgery for surgery performed by trainee surgeons with the use of a low-cost viscoelastic

    Directory of Open Access Journals (Sweden)

    R Muralidhar

    2012-01-01

    Full Text Available Context : Pediatric cataract surgery is traditionally done with the aid of high-molecular-weight viscoelastics which are expensive. It needs to be determined if low-cost substitutes are just as successful. Aims : The study aims to determine the success rates for anterior and posterior capsulorrhexis and intraocular lens (IOL implantation in the bag for pediatric cataract surgery performed with the aid of a low-molecular-weight viscoelastic. Settings and Design : Nonrandomized observational study. Materials and Methods: Children less than 6 years of age who underwent cataract surgery with IOL implantation in the period May 2008-May 2009 were included. The surgeries were done by pediatric ophthalmology fellows. A standard procedure of anterior capsulorrhexis, lens aspiration with primary posterior capsulorrhexis, anterior vitrectomy, and IOL implantation was followed. Three parameters were studied: successful completion of anterior and posterior capsulorrhexis and IOL implantation in the bag. Results: 33 eyes of 28 children were studied. The success rate for completion was 66.7% and 88.2 % for anterior and posterior capsulorrhexis, respectively. IOL implantation in the bag was successful in 87.9%. Conclusions: 2% hydroxypropylmethylcellulose is a viable low-cost alternative to more expensive options similar to high-molecular-weight viscoelastics. This is of great relevance to hospitals in developing countries.

  6. Allogeneic human dermal fibroblasts are viable in peripheral blood mononuclear co-culture

    Directory of Open Access Journals (Sweden)

    Restu Syamsul Hadi

    2014-08-01

    Full Text Available Background Transplanted allogeneic dermal fibroblasts retain stem cell subpopulations, and are easily isolated, expanded and stored using standard techniques. Their potential for regenerative therapy of chronic wounds should be evaluated. The aim of this study was to determine allogeneic fibroblast viability in the presence of peripheral blood mononuclear cells (PBMC. Methods In this experimental study, fibroblasts were isolated from foreskin explants, expanded in the presence of serum, and stored using slow-freezing. We used one intervention group of allogeneic fibroblasts co-cultured with PBMC and 2 control groups of separate fibroblast and PBMC cultures.Fibroblasts were characterized by their collagen secretion and octamer-binding transcription factor 4 (OCT4 expression. Viability was evaluated using water soluble tetrazolium-1 (WST-1 proliferation assay. Absorbances were measured at 450 nm. Data analysis was performed by student’s paired t-test. Results Dermal fibroblasts were shown to secrete collagen, express OCT4, be recoverable after cryopreservation, and become attached to the culture dish in a co-culture with PBMC. Co-cultured and control fibroblasts had no significantly different cell viabilities (p>0.05. Calculated viable cell numbers increased 1.8 and 5.1-fold, respectively, at days 2 and 4 in vitro. Both groups showed comparable doubling times at days 2 and 4 in vitro. PBMC did not interfere with allogeneic fibroblast viability and proliferative capacity Conclusions Allogeneic fibroblasts remain viable and proliferate in the presence of host PBMC. Future research should evaluate allogeneic human dermal fibroblast competency in clinical settings. Dermal fibroblasts are a potential source for cell therapy in chronic wound management.

  7. Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: optical performance and clinical outcomes.

    Science.gov (United States)

    Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane

    2015-01-01

    Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients' satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material. Copyright © 2014. Published by Elsevier Espana.

  8. Chimeric autologous/allogeneic constructs for skin regeneration.

    Science.gov (United States)

    Rasmussen, Cathy Ann; Tam, Joshua; Steiglitz, Barry M; Bauer, Rebecca L; Peters, Noel R; Wang, Ying; Anderson, R Rox; Allen-Hoffmann, B Lynn

    2014-08-01

    The ideal treatment for severe cutaneous injuries would eliminate the need for autografts and promote fully functional, aesthetically pleasing autologous skin regeneration. NIKS progenitor cell-based skin tissues have been developed to promote healing by providing barrier function and delivering wound healing factors. Independently, a device has recently been created to "copy" skin by harvesting full-thickness microscopic tissue columns (MTCs) in lieu of autografts traditionally harvested as sheets. We evaluated the feasibility of combining these two technologies by embedding MTCs in NIKS-based skin tissues to generate chimeric autologous/allogeneic constructs. Chimeric constructs have the potential to provide immediate wound coverage, eliminate painful donor site wounds, and promote restoration of a pigmented skin tissue possessing hair follicles, sweat glands, and sebaceous glands. After MTC insertion, chimeric constructs and controls were reintroduced into air-interface culture and maintained in vitro for several weeks. Tissue viability, proliferative capacity, and morphology were evaluated after long-term culture. Our results confirmed successful MTC insertion and integration, and demonstrated the feasibility of generating chimeric autologous/allogeneic constructs that preserved the viability, proliferative capacity, and structure of autologous pigmented skin. These feasibility studies established the proof-of-principle necessary to further develop chimeric autologous/allogeneic constructs for the treatment of complex skin defects. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  9. 'Mini' total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Avramova, V.; Vassileva, V.; Georgieva, S.; Sultanov, B.

    2006-01-01

    Full text: The total body irradiation (TBI) combined with intensive chemotherapy plays an important role in the preparation of patients for bone marrow transplantation (BMT). The first autologous BMT in Bulgaria was performed in 1997 in the Specialized Pediatric Hospital for Active Treatment (SPHAT) of oncohematological diseases. The first TBI, followed by allogeneic BMT, was carried out in 2002 in the 'Queen Giovanna' University Hospital, after which its routine application as a basic form of large field radiotherapy and a main stage of the conditioning regimen for BMT was started. Fourteen allogeneic BMTs including TBI as a basic conditioning regimen have been performed till May 2006. The objective of the present report is to present the first clinical observations in the Bulgarian oncological practice on 'mini' TBI followed by allogeneic blood stem cell transplantation. During the period October 2005 - May 2006, 'mini' TBI followed by allogeneic BMT was carried out for two patients of the age 43 and 50 years. The diagnosis of both patients was acute non-lymphoblastic leukemia, in the remission stage, after one relapse, respectively. Intensive preceding chemotherapy was applied for both patients. A conditioning regimen was applied including the fludarabine purine analogue (3 x 30 mg/m 2 ) and 200 cGy TBI. It was followed by transplantation of allogeneic cell concentrate containing 2.5 x10 6 /kg CD34+ and 4.0 x10 6 /kg CD34+ blood stem cells of partially compatible family donors (a sister and a son), which were tolerable for the patients without complications. Cyclosporine and mycophelonate mofetile were applied as post-transplantation treatment. Active antibiotic, antiviral, symptomatic and substituting therapy, as well as GvHD prophylaxis was applied for both patients. Good clinical tolerance was recorded for the applied low dose conditioning regimen. The patients were discharged within 30 days in good general condition and stable draft action, with

  10. Anterior capsulotomy with an ultrashort-pulse laser.

    Science.gov (United States)

    Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith

    2011-05-01

    To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Anterior segment optical coherence tomography for evaluation of cornea and ocular surface

    Directory of Open Access Journals (Sweden)

    Mittanamalli S Sridhar

    2018-01-01

    Full Text Available Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple. Several devices and technologies allow to explore and manage patients better. Optical coherence tomography (OCT technology has evolved over the years, and hence a detailed evaluation of anterior segment (AS structures such as cornea, conjunctiva, tear meniscus, anterior chamber, iris, and crystalline lens has been possible in a noncontact and safe procedure. The purpose of this special issue is to present and update in the evaluation of cornea and ocular surface, and this paper reviews a description of the AS-OCT, presenting the technology and common clinical uses of OCT in the management of diseases involving cornea and ocular surface to provide an updated information of the clinical recommendations of this technique in eye care practice.

  12. Tolerance, immunocompetence, and secondary disease in fully allogeneic radiation chimeras

    International Nuclear Information System (INIS)

    Rayfield, L.S.; Brent, L.

    1983-01-01

    The aim of this study was to ascertain the extent to which secondary disease and mortality in fully allogeneic chimeras (C57BL leads to CBA) is caused (if at all) by a delayed graft-versus-host reaction. Adult CBA males were thymectomized, irradiated, and reconstituted with T-lymphocyte-depleted C57BL or CBA bone marrow cells (BMC), followed three weeks after irradiation by implantation under the kidney capsule of thymic lobes from C57BL or CBA fetal or adult donors. These mice were observed for the development of secondary disease for periods in excess of 250 days, and they were examined at 5 weeks or 4 months for T lymphocyte reactivity and tolerance to alloantigens, using the cell-mediated lympholysis assay (CML). The following results were obtained. First, removal of T lymphocytes with anti-Thy 1 antibody and complement from allogeneic bone marrow did not prevent wasting and eventual death, although it prolonged the lifespan of mice substantially. Second, T lymphocytes generated from bone marrow-derived precursor cells became tolerant of the histocompatibility antigens of the thymus donor strain but remained normally reactive to third-party antigens. Third, allogeneic radiation chimeras did not survive as well as animals reconstituted with syngeneic cells, even when they were demonstrably tolerant in CML. Fourth, C57BL BMC maturing in a CBA host equipped with a C57BL thymus graft did not become tolerant of host antigens, indicating that extra-thymic tolerance does not occur in fully allogeneic--as opposed to semiallogeneic--chimeras. It is argued that the function of B lymphocytes and/or accessory cells is impaired in fully allogeneic radiation chimeras, and that the mortality observed was directly related to the resulting immunodeficiency. The relevance of the results described in this paper to clinical bone marrow transplantation is discussed

  13. Reduction in requirements for allogeneic blood products: nonpharmacologic methods.

    Science.gov (United States)

    Hardy, J F; Bélisle, S; Janvier, G; Samama, M

    1996-12-01

    Various strategies have been proposed to decrease bleeding and allogeneic transfusion requirements during and after cardiac operations. This article attempts to document the usefulness, or lack thereof, of the nonpharmacologic methods available in clinical practice. Blood conservation methods were reviewed in chronologic order, as they become available to patients during the perisurgical period. The literature in support of or against each strategy was reexamined critically. Avoidance of preoperative anemia and adherence to published guidelines for the practice of transfusion are of paramount importance. Intraoperatively, tolerance of low hemoglobin concentrations and use of autologous blood (predonated or harvested before bypass) will reduce allogeneic transfusions. The usefulness of plateletpheresis and retransfusion of shed mediastinal fluid remains controversial. Intraoperatively and postoperatively, maintenance of normothermia contributes to improved hemostasis. Several approaches have been shown to be effective. An efficient combination of methods can reduce, and sometimes abolish, the need for allogeneic blood products after cardiac operations, inasmuch as all those involved in the care of cardiac surgical patients adhere thoughtfully to existing transfusion guidelines.

  14. Effect of hemodialysis on intraocular lens power calculation.

    Science.gov (United States)

    Çalışkan, Sinan; Çelikay, Osman; Biçer, Tolga; Aylı, Mehmet Deniz; Gürdal, Canan

    2016-01-01

    To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Mean difference in AL before and after HD was -0.041 ± 0.022 mm with ICCs > 0.90 (p  0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations.

  15. Review of application of mass spectrometry for analyses of anterior eye proteome

    Institute of Scientific and Technical Information of China (English)

    Sherif; Elsobky; Ashley; M; Crane; Michael; Margolis; Teresia; A; Carreon; Sanjoy; K; Bhattacharya

    2014-01-01

    Proteins have important functional roles in the body, which can be altered in disease states. The eye is a complex organ rich in proteins; in particular, the anterior eye is very sophisticated in function and is most commonly involved in ophthalmic diseases. Proteomics, the large scale study of proteins, has greatly impacted our knowledge and understanding of gene function in the post-genomic period. The most significant breakthrough in proteomics has been mass spectrometric identification of proteins, which extends analysis far beyond the mere display of proteins that classical techniques provide. Mass spectrometry functions as a "mass analyzer" which simplifies the identification and quantification of proteins extracted from biological tissue. Mass spectrometric analysis of the anterior eye proteome provides a differential display for protein comparison of normal and diseased tissue. In this article wepresent the key proteomic findings in the recent literature related to the cornea, aqueous humor, trabecular meshwork, iris, ciliary body and lens. Through this we identified unique proteins specific to diseases related to the anterior eye.

  16. Clinical Allogeneic and Autologous Islet Cell Transplantation: Update

    Directory of Open Access Journals (Sweden)

    Shinichi Matsumoto

    2011-06-01

    Full Text Available Islet cell transplantation is categorized as a β-cell replacement therapy for diabetic patients who lack the ability to secrete insulin. Allogeneic islet cell transplantation is for the treatment of type 1 diabetes, and autologous islet cell transplantation is for the prevention of surgical diabetes after a total pancreatectomy. The issues of allogeneic islet cell transplantation include poor efficacy of islet isolation, the need for multiple donor pancreata, difficulty maintaining insulin independence and undesirable side effects of immunosuppressive drugs. Those issues have been solved step by step and allogeneic islet cell transplantation is almost ready to be the standard therapy. The donor shortage will be the next issue and marginal and/or living donor islet cell transplantation might alleviate the issue. Xeno-islet cell transplantation, β-cell regeneration from human stem cells and gene induction of the naïve pancreas represent the next generation of β-cell replacement therapy. Autologous islet cell transplantation after total pancreatectomy for the treatment of chronic pancreatitis with severe abdominal pain is the standard therapy, even though only limited centers are able to perform this treatment. Remote center autologous islet cell transplantation is an attractive option for hospitals performing total pancreatectomies without the proper islet isolation facilities.

  17. Phakic Intraocular Lens Implantation: Refractive Outcome and Safety in Patients with Anterior Chamber Depth between 2.8 and 3.0 versus ≥3.0 mm.

    Science.gov (United States)

    Guerra, Marta G; Silva, Andreia M M; Marques, Sara H M; Melo, Sofia H; Póvoa, João A; Lobo, Conceição; Murta, Joaquim Neto

    2017-01-01

    To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation. © 2017 S. Karger AG, Basel.

  18. Allogeneic epidermal substitutes in the treatment of chronic diabetic leg and foot ulcers

    Directory of Open Access Journals (Sweden)

    Andrea Marchesi

    2014-09-01

    Full Text Available Aim: Diabetic foot ulcers are the most common cause of nontraumatic lower extremity amputations in the industrialized world. Tissue-engineering products offer a lower extremity salvage strategy when healing does not proceed according to the standard of care. New allogeneic sheets are available for the management of diabetic leg and foot ulcers. Methods: The endpoints of this case series study regard preliminary outcomes of the application of allogeneic keratinocytes composed of benzyl ester of hyaluronic acid to 16 diabetic foot and leg ulcers in 11 patients with type 2 diabetes mellitus. Results: Between 21 and 70 days after cellular therapy, 6 out of 16 lesions were completely healed, reducing the wound dimension by 70% and improving the wound bed score by 52%. Conclusion: The clinical results of the new allogeneic sheets indicate that allogeneic keratinocytes may represent an effective and safe therapy for diabetic foot and leg ulcers in the multidisciplinary approach to this diabetes-related complication.

  19. Sectioning a luxated intraocular lens inside the vitreous cavity.

    Science.gov (United States)

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Post-lens tear turbidity and visual quality after scleral lens wear.

    Science.gov (United States)

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p turbidity. © 2017 Optometry Australia.

  1. The Role of Allogeneic Transplantation in the Treatment of Multiple Myeloma.

    Science.gov (United States)

    Majolino, I

    1998-01-01

    In multiple myeloma (MM) attempts to improve upon the results of standard melphalanpredisone with other conventional dose drug combinations, have generally been unsuccessful, producing only minor improvements in response rate, with little effect on survival. The only treatment capable of producing a dramatic change in response and life expectancy is high-dose chemo-radiotherapy followed by stem cell transplantation. However, after autologous transplant relapse will almost inevitably occur, and freedom from recurrence curves show no plateau in most studies. Besides the resistance of the disease to chemotherapy, another possible explanation is tumor contamination of the graft. This is one major advantage of allogeneic transplantation over autologous, the other being an immune mediated mechanism of tumor suppression in part related to GVHD. Application of allogeneic transplantation to MM has met a number of obstacles, but is now entering a phase of reappraisal, due in part to a tendency to earlier transplantation, in part to the use of novel technologies such as allogeneic peripheral blood stem cells instead of marrow. The goal should be the reduction of transplant related deaths, to better exploit the higher eradication potential of allogeneic cell therapies. The most intriguing perspectives are those related to immune manipulation of recipient and/or donor.

  2. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    Science.gov (United States)

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  3. Determining spherical lens correction for astronaut training underwater.

    Science.gov (United States)

    Porter, Jason; Gibson, C Robert; Strauss, Samuel

    2011-09-01

    To develop a model that will accurately predict the distance spherical lens correction needed to be worn by National Aeronautics and Space Administration astronauts while training underwater. The replica space suit's helmet contains curved visors that induce refractive power when submersed in water. Anterior surface powers and thicknesses were measured for the helmet's protective and inside visors. The impact of each visor on the helmet's refractive power in water was analyzed using thick lens calculations and Zemax optical design software. Using geometrical optics approximations, a model was developed to determine the optimal distance spherical power needed to be worn underwater based on the helmet's total induced spherical power underwater and the astronaut's manifest spectacle plane correction in air. The validity of the model was tested using data from both eyes of 10 astronauts who trained underwater. The helmet's visors induced a total power of -2.737 D when placed underwater. The required underwater spherical correction (FW) was linearly related to the spectacle plane spherical correction in air (FAir): FW = FAir + 2.356 D. The mean magnitude of the difference between the actual correction worn underwater and the calculated underwater correction was 0.20 ± 0.11 D. The actual and calculated values were highly correlated (r = 0.971) with 70% of eyes having a difference in magnitude of astronauts. The model accurately predicts the actual values worn underwater and can be applied (more generally) to determine a suitable spectacle lens correction to be worn behind other types of masks when submerged underwater.

  4. Influence of a prolonged period of low-dosage x-rays on the optic and ultrastructural appearances of cataract of the human lens

    International Nuclear Information System (INIS)

    Hayes, B.P.; Fisher, R.F.

    1979-01-01

    Human lenses extracted for cataract 26 years after long-term exposure to an imperfectly shielded radium source were examined by slit-lamp photography, thin-section light microscopy, and electron microscopy. Anterior epithelial cells were fibroblast-like, and germinal epithelium and vacuolated cortical fibres had accumulated at the equator. A zone of light scatter at the anterior pole corresponded to an area of breakdown of cortical lens fibres, where unusual feathery fibres were orientated perpendicular to the lens surface. Two zones of light scatter separated by a 250-micrometer clear interval were seen in the posterior cortex. The zone at the posterior pole corresponded to an area of fibre liquefaction and large rounded membrane whorls, while the deeper zone comprised small flattened membrane whorls. The characteristic plaques of swollen abnormal cells described in previous histological studies of x-ray cataract were not present. This and other differences probably reflect the extremely long time course and repeated subliminal doses to which the patient was exposed. (author)

  5. Surgical results of a one-stage combined anterior lumbosacral fusion and posterior percutaneous pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Chien-Yuan Huang

    2018-01-01

    Full Text Available Objectives: Lumbosacral fusion through either an anterior or a posterior approach to achieve good lordosis and stability is always a challenging surgical operation and is often accompanied by a higher rate of pseudarthrosis than when other lumbar segments are involved. This study evaluated the clinical and radiological results of lumbosacral fusions achieved through a combined anterior and posterior approach. Materials and Methods: From June 2008 to 2012, 20 patients who had L5–S1 instability and stenosis were consecutively treated, first by anterior interbody fusion using an allogenous strut bone graft through the pararectus approach and then by posterior pedicle screw fixation. A minimum of 1-year of clinical and radiological follow-up was conducted. Intraoperative blood loss, surgical time, and any surgery-related complications were recorded. Clinical outcomes were assessed using a visual analog scale (VAS and the patient's Oswestry Disability Index (ODI score. After 1 year, radiological outcomes were assessed by analyzing pelvic incidence, lumbar lordosis, and segmental lordosis using static plain films, while fusion stability was assessed using dynamic plain films. Results: The mean operative time and blood loss were 215 min and 325 cc, respectively. After 1 year, the VAS and ODI scores had significantly improved, and stable fusion with good lordotic curvature was obtained in all cases. Conclusion: The surgical results of the combined procedure are satisfactory in terms of the functional and radiological outcomes. Our method offers advantages regarding both anterior fusion and posterior fixation.

  6. Anterior capsular staining with trypan blue for capsulorhexis in mature and hypermature cataracts. A preliminary study

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2001-01-01

    Full Text Available Purpose: To study the efficacy and safety of 0.1% Trypan Blue dye to stain the anterior capsule for capsulorhexis in mature and hypermature cataracts. Methods: This preliminary study included 25 eyes of 25 patients with a unilateral mature or hypermature cataract, including one case of traumatic mature cataract. In all these cases 0.2ml of 0.1% trypan blue dye was used to stain the anterior capsule. The efficacy and safety of the dye was evaluated on the basis of intraoperative and postoperative observations. Results: In all 25 eyes the capsulorhexis was completed. There was peripheral extension of the capsulorhexis in the eye with traumatic cataract and the stained edge of the anterior capsule helped identification and redirection of the capsulorhexis. Successful phacoemulsification with intraocular lens implantation was performed in all eyes. Adverse reactions related to the dye such as raised intraocular pressure, anterior chamber inflammation and endothelial damage were not observed in the immediate postoperative period or at the end of mean follow-up of 3 months. Conclusion: Trypan blue dye staining of the anterior capsule appears to be a very useful and safe technique that simplifies capsulorhexis in mature and hypermature cataracts.

  7. Financial burden in recipients of allogeneic hematopoietic cell transplantation.

    Science.gov (United States)

    Khera, Nandita; Chang, Yu-hui; Hashmi, Shahrukh; Slack, James; Beebe, Timothy; Roy, Vivek; Noel, Pierre; Fauble, Veena; Sproat, Lisa; Tilburt, Jon; Leis, Jose F; Mikhael, Joseph

    2014-09-01

    Although allogeneic hematopoietic cell transplantation (HCT) is an expensive treatment for hematological disorders, little is known about the financial consequences for the patients who undergo this procedure. We analyzed factors associated with its financial burden and its impact on health behaviors of allogeneic HCT recipients. A questionnaire was retrospectively mailed to 482 patients who underwent allogeneic HCT from January 2006 to June 2012 at the Mayo Clinic, to collect information regarding current financial concerns, household income, employment, insurance, out-of-pocket expenses, and health and functional status. A multivariable logistic regression analysis identified factors associated with financial burden and treatment nonadherence. Of the 268 respondents (56% response rate), 73% reported that their sickness had hurt them financially. All patients for whom the insurance information was available (missing, n = 13) were insured. Forty-seven percent of respondents experienced financial burden, such as household income decreased by >50%, selling/mortgaging home, or withdrawing money from retirement accounts. Three percent declared bankruptcy. Younger age and poor current mental and physical functioning increased the likelihood of financial burden. Thirty-five percent of patients reported deleterious health behaviors because of financial constraints. These patients were likely to be younger, have lower education, and with a longer time since HCT. Being employed decreased the likelihood of experiencing financial burden and treatment nonadherence due to concern about costs. A significant proportion of allogeneic HCT survivors experience financial hardship despite insurance coverage. Future research should investigate potential interventions to help at-risk patients and prevent adverse financial outcomes after this life-saving procedure. Copyright © 2014 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Semi-allogeneic dendritic cells can induce antigen-specific T-cell activation, which is not enhanced by concurrent alloreactivity.

    Science.gov (United States)

    Wells, James W; Cowled, Chris J; Darling, David; Guinn, Barbara-Ann; Farzaneh, Farzin; Noble, Alistair; Galea-Lauri, Joanna

    2007-12-01

    Alloreactive T-cell responses are known to result in the production of large amounts of proinflammatory cytokines capable of activating and maturing dendritic cells (DC). However, it is unclear whether these allogeneic responses could also act as an adjuvant for concurrent antigen-specific responses. To examine effects of simultaneous alloreactive and antigen-specific T-cell responses induced by semi-allogeneic DC. Semi-allogeneic DC were generated from the F(1) progeny of inbred strains of mice (C57BL/6 and C3H, or C57BL/6 and DBA). We directly primed antigen-specific CD8(+) and CD4(+) T-cells from OT-I and OT-II mice, respectively, in the absence of allogeneic responses, in vitro, and in the presence or absence of alloreactivity in vivo. In vitro, semi-allogeneic DC cross-presented ovalbumin (OVA) to naïve CD8(+) OT-I transgenic T-cells, primed naïve CD4(+) OT-II transgenic T-cells and could stimulate strong alloreactive T-cell proliferation in a primary mixed lymphocyte reaction (MLR). In vivo, semi-allogeneic DC migrated efficiently to regional lymph nodes but did not survive there as long as autologous DC. In addition, they were not able to induce cytotoxic T-lymphocyte (CTL) activity to a target peptide, and only weakly stimulated adoptively transferred OT-II cells. The CD4(+) response was unchanged in allo-tolerized mice, indicating that alloreactive T-cell responses could not provide help for concurrently activated antigen-specific responses. In an EL4 tumour-treatment model, vaccination with semi-allogeneic DC/EL4 fusion hybrids, but not allogeneic DC/EL4 hybrids, significantly increased mouse survival. Expression of self-Major histocompatibility complex (MHC) by semi-allogeneic DC can cause the induction of antigen-specific immunity, however, concurrently activated allogeneic bystander responses do not provide helper or adjuvant effects.

  9. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  10. Lens artifacts in human fetal eyes - the challenge of interpreting the histomorphology of human fetal lenses.

    Science.gov (United States)

    Herwig, Martina C; Müller, Annette M; Klarmann-Schulz, Ute; Holz, Frank G; Loeffler, Karin U

    2014-01-01

    Evaluation of the lens, including cataractous changes, is often of paramount importance in the classification of fetal syndromes or forensic questions. On histology, the crystalline lens is - especially in fetal and infant eyes - an organ susceptible to numerous artifacts. Thus, the aim of our study was to study various factors (including fixatives) that might have an impact on lens histomorphology. Twenty eyes from ten fetuses (formalin fixation: n = 10, glutaraldehyde fixation: n = 10), matched for gestational age and abortion (spontaneous vs. induced), were investigated macroscopically and by light microscopy. Sections were stained with routine hematoxylin & eosin (H&E), and periodic acid schiff (PAS). The age of the fetal eyes ranged from 15 to 36 weeks of gestation. Lens artifacts were analyzed and compared to fetal and adult lenses with definitive cataractous changes. In addition, 34 eyes from 27 fetuses with trisomy 21 were investigated for lens changes. All lenses showed artifacts of varying extent, in particular globules, vacuoles, clefts, anterior/posterior capsular separation, subcapsular proteinaceous material, fragmentation of the lens capsule/epithelium, and a posterior umbilication. Glutaraldehyde-fixed lenses displayed less artifacts compared to those fixed in formalin. Slight differences in the appearance of artifacts were found dependent on the fixative (formaldehyde vs glutaraldehyde) and the kind of abortion (iatrogenous vs spontaneous). The gestational age did not have a significant influence on the type and extent of lens artifacts. The lenses from fetuses with trisomy 21 displayed similar lens artifacts with no specific findings. Alterations in fetal lens morphology are extremely frequent and variable. These artifacts have to be carefully taken into account when interpreting post-mortem findings. Thus, the postmortem diagnosis of a fetal cataract should be made with great caution, and should include, in adherence to our proposed

  11. Allogenic blood transfusion following total hip arthroplasty: results from the nationwide inpatient sample, 2000 to 2009.

    Science.gov (United States)

    Saleh, Anas; Small, Travis; Chandran Pillai, Aiswarya Lekshmi Pillai; Schiltz, Nicholas K; Klika, Alison K; Barsoum, Wael K

    2014-09-17

    The large-scale utilization of allogenic blood transfusion and its associated outcomes have been described in critically ill patients and those undergoing high-risk cardiac surgery but not in patients undergoing elective total hip arthroplasty. The objective of this study was to determine the trends in utilization and outcomes of allogenic blood transfusion in patients undergoing primary total hip arthroplasty in the United States from 2000 to 2009. An observational cohort of 2,087,423 patients who underwent primary total hip arthroplasty from 2000 to 2009 was identified in the Nationwide Inpatient Sample. International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes 99.03 and 99.04 were used to identify patients who received allogenic blood products during their hospital stay. Risk factors for allogenic transfusions were identified with use of multivariable logistic regression models. We used propensity score matching to estimate the adjusted association between transfusion and surgical outcomes. The rate of allogenic blood transfusion increased from 11.8% in 2000 to 19.0% in 2009. Patient-related risk factors for receiving an allogenic blood transfusion include an older age, female sex, black race, and Medicaid insurance. Hospital-related risk factors include rural location, smaller size, and non-academic status. After adjusting for confounders, allogenic blood transfusion was associated with a longer hospital stay (0.58 ± 0.02 day; p conservation methods. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Adverse impact of multileaf collimator field shaping on lens dose in children with acute leukemia receiving cranial irradiation

    International Nuclear Information System (INIS)

    Kalapurakal, John A.; Sathiaseelan, Vythialingam; Bista, Tomasz C.; Marymont, Maryanne H.

    2000-01-01

    Purpose: This study was designed to investigate the impact of multileaf collimator (MLC) on lens dose in children with leukemia undergoing cranial irradiation. Methods and Materials: This is a prospective study utilizing three common cranial irradiation techniques. Technique A uses a half-beam, nondivergent radiation field. Technique B has the anterior divergent field edge at the lateral bony canthus. Technique C is similar to B, but with a field collimator angle. Thermoluminescent dosimeter (TLD) lens dose measurements were obtained in children and phantom with all three techniques. Results: Seventeen children were studied. Lens dose measurements were obtained in 14 children with technique A using MLC and blocks. In 7 of 14 children, dose measurements were obtained with MLC only. One child was treated with technique B and 2 children were treated with C, with MLC ± blocks. In all 3 techniques, with MLC alone, the lens dose increased by 64%, 119%, and 72%, respectively. Similar results were obtained in phantom. Conclusion: This study demonstrates that independent of irradiation technique, additional custom blocking is required to maximally protect the lens with MLC shaped fields. This is due to the lack of conformity between MLC and the desired field edge at the lateral bony canthus

  13. Achieving an early pregnancy following allogeneic uterine transplantation in a rabbit model

    OpenAIRE

    Saso, Srdjan; Petts, Gemma; David, Anna L.; Thum, Meen-Yau; Chatterjee, Jayanta; Vicente Antón, José Salvador; Marco Jiménez, Francisco; Corless, David; Boyd, Michael; Noakes, David; Lindsay, Iain; Del Priorei, Giuseppe; Ghaem-Maghami, Sadaf; Smith, J. Richard

    2015-01-01

    [EN] Objective: Uterine transplantation (UTx) has been proposed as a treatment option for women diagnosed with absolute uterine factor infertility (AUFI). The goal of UTx remains achieving pregnancy and live birth of a healthy neonate following allogeneic UTx. Our aim was to assess whether fertility was possible following allogeneic uterine transplantation (UTx), when the recipient had demonstrated long-term survival and had been administered immunosuppression. Study desig...

  14. Relationship between intraocular pressure and angle configuration: an anterior segment OCT study.

    Science.gov (United States)

    Chong, Rachel S; Sakata, Lisandro M; Narayanaswamy, Arun K; Ho, Sue-Wei; He, Mingguang; Baskaran, Mani; Wong, Tien Yin; Perera, Shamira A; Aung, Tin

    2013-03-05

    To assess the relationship between intraocular pressure (IOP) and anterior chamber angle (ACA) configuration as assessed by gonioscopy and anterior segment optical coherence tomography (AS-OCT). A total of 2045 subjects aged 50 years and older, were recruited from a community clinic and underwent AS-OCT, Goldmann applanation tonometry, and gonioscopy. A quadrant was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen. A closed quadrant on AS-OCT was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. Customized software (Zhongshan Angle Assessment Program, Guangzhou, China) was used to measure AS-OCT parameters on AS-OCT scans, including anterior chamber depth, area, and volume; iris thickness (IT) and curvature; lens vault; angle opening distance; and trabecular-iris space area. IOP values were adjusted for age, sex, diabetes and hypertension status, body mass index, central corneal thickness, and presence of peripheral anterior synechiae. Mean age of study subjects was 63.2 ± 8.0 years, 52.6% were female, and 89.4% were Chinese. Mean IOP was 14.8 ± 2.4 mm Hg (range 826). IOP (mean ± SE) increased with number of quadrants with gonioscopic angle closure (none: 14.6 ± 0.2; one: 14.7 ± 0.3; two: 15.0 ± 0.3; three: 15.0 ± 0.3; four: 15.6 ± 0.3 mm Hg; P gonioscopy, with increasing IOP.

  15. Biometric analysis of pigment dispersion syndrome using anterior segment optical coherence tomography.

    Science.gov (United States)

    Aptel, Florent; Beccat, Sylvain; Fortoul, Vincent; Denis, Philippe

    2011-08-01

    To compare anterior chamber volume (ACV), iris volume, and iridolenticular contact (ILC) area before and after laser peripheral iridotomy (LPI) in eyes with pigment dispersion syndrome (PDS) using anterior segment optical coherence tomography (AS OCT) and image processing software. Cross-sectional study. Eighteen eyes of 18 patients with PDS; 30 eyes of 30 controls matched for age, gender, and refraction. Anterior segment OCT imaging was performed in all eyes before LPI and 1, 4, and 12 weeks after LPI. At each visit, 12 cross-sectional images of the AS were taken: 4 in bright conditions with accommodation (accommodation), 4 in bright conditions without accommodation (physiological miosis), and 4 under dark conditions (physiologic mydriasis). Biometric parameters were estimated using AS OCT radial sections and customized image-processing software. Anterior chamber volume, iris volume-to-length ratio, ILC area, AS OCT anterior chamber depth, and A-scan ultrasonography axial length. Before LPI, PDS eyes had a significantly greater ACV and ILC area than control eyes (PPigment dispersion syndrome eyes do not have an iris that is abnormally large, relative to the AS size, but have a weakly resistant iris that is stretched and pushed against the lens when there is a pressure difference across the iris. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Different alpha crystallin expression in human age-related and congenital cataract lens epithelium.

    Science.gov (United States)

    Yang, Jing; Zhou, Sheng; Guo, Minfei; Li, Yuting; Gu, Jianjun

    2016-05-28

    The purpose of this study was to investigate the different expressions of αA-crystallin and αB-crystallin in human lens epithelium of age-related and congenital cataracts. The central part of the human anterior lens capsule approximately 5 mm in diameter together with the adhering epithelial cells, were harvested and processed within 6 hours after cataract surgery from age-related and congenital cataract patients or from normal eyes of fresh cadavers. The mRNA and soluble protein levels of αA-crystallin and αB-crystallin in the human lens epithelium were detected by real-time PCR and western blots, respectively. The mRNA and soluble protein expressions of αA-crystallin and αB-crystallin in the lens epithelium were both reduced in age-related and congenital cataract groups when compared with the normal control group. However, the degree of α-crystallin loss in the lens epithelium was highly correlated with different cataract types. The α-crystallin expression of the lens epithelium was greatly reduced in the congenital cataract group but only moderately decreased in the age-related cataract group. The reduction of αA-crystallin soluble protein levels in the congenital cataract group was approximately 2.4 fold decrease compared with that of the age-related cataract group, while an mRNA fold change of 1.67 decrease was observed for the age-related cataract group. Similarly, the reduction of soluble protein levels of αB-crystallin in the congenital cataract group was approximately a 1.57 fold change compared with that of the age-related cataract group. A 1.75 fold change for mRNA levels compared with that of the age-related cataract group was observed. The results suggest that the differential loss of α-crystallin in the human lens epithelium could be associated with the different mechanisms of cataractogenesis in age-related versus congenital cataracts, subsequently resulting in different clinical presentations.

  17. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  18. Allogenic bone grafts used at Central Hospital during June 1995 to July 1998

    International Nuclear Information System (INIS)

    Yolchai Jongjirasiri; Yongyudh Vajaradul

    1999-01-01

    Producing and using allogenic bone graft in Thailand began ten years ago. There are approximately 1,000 cases a year on orthopaedic surgery at Central Hospital. For using allogenic bone graft from the Bangkok Biomaterial Center, 66 cases were operated since June 1995. This was generated by 30 in males, 36 in females and by ages between 12-81 years old. After the operation, 43 cases had bone gap from injuries and 19 cases, fusion of spondylolisthesis and scoliosis were done. Four cases had tumor surgery, and 59 out of 66 cases had good bone union that is 89%. Delayed union happened in 6 cases only. Immune response to allogenic bone graft has not been found yet

  19. Allogeneic CD19-CAR-T cell infusion after allogeneic hematopoietic stem cell transplantation in B cell malignancies.

    Science.gov (United States)

    Liu, Jun; Zhong, Jiang F; Zhang, Xi; Zhang, Cheng

    2017-01-31

    Allogeneic hematopoietic stem cell transplantation (allo-HSCT) is considered the cornerstone in treatment of hematological malignancies. However, relapse of the hematological disease after allo-HSCT remains a challenge and is associated with poor long-term survival. Chimeric antigen receptor redirected T cells (CAR-T cells) can lead to disease remission in patients with relapsed/refractory hematological malignancies. However, the therapeutic window for infusion of CAR-T cells post allo-HSCT and its efficacy are debatable. In this review, we first discuss the use of CAR-T cells for relapsed cases after allo-HSCT. We then review the toxicities and the occurrence of graft-versus-host disease in relapsed patients who received CAR-T cells post allo-HSCT. Finally, we review clinical trial registrations and the therapeutic time window for infusion of CAR-T cells post allo-HSCT. The treatment of allogeneic CAR-T cells is beneficial for patients with relapsed B cell malignancies after allo-HSCT with low toxicities and complications. However, multicenter clinical trials with larger sample sizes should be performed to select the optimal therapeutic window and confirm its efficacy.

  20. Publication analysis of the contact lens field: what are the current topics of interest?

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2015-01-01

    To determine the main current research interests of scientists working in the contact lens field. All articles published in the 2011 issues of all journals included in the Journal Citation Reports subject category Ophthalmology were inspected to expose those papers related to the contact lens field. Information regarding source journal was obtained and authorship details were recorded to determine the top most prolific authors, institutions and countries. A comprehensive list of key words was compiled to generate a two-dimensional term map in which the frequency of occurrence of a particular term is defined by label size and the distance between two terms is an indication of the relatedness of these terms, based on their co-occurrences within groups of key words. Clusters of related terms were also identified. Visual examination of all articles uncovered a total of 156 papers, published in 28 different journals. Contact Lens & Anterior Eye, Eye & Contact Lens and Optometry and Vision Science had 27 articles each. The most prolific authors and institutions revealed the predominance of countries with long research tradition in the contact lens field. Ten different word clusters or areas of interest were identified, including both traditional, yet unresolved issues (e.g., comfort or dry eye), and the latest research efforts (e.g., myopia control). These findings, which revealed contact lenses to be a fertile area of research, may be of relevance to new researchers as well as to those interested in exploring the latest research trends in this scientific discipline. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  1. AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source

    Science.gov (United States)

    Nightingale, J. W.; Dye, S.; Massey, Richard J.

    2018-05-01

    This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.

  2. Modification of hydrophobic acrylic intraocular lens with poly(ethylene glycol) by atmospheric pressure glow discharge: A facile approach

    International Nuclear Information System (INIS)

    Lin Lin; Wang Yao; Huang Xiaodan; Xu Zhikang; Yao Ke

    2010-01-01

    To improve the anterior surface biocompatibility of hydrophobic acrylic intraocular lens (IOL) in a convenient and continuous way, poly(ethylene glycol)s (PEGs) were immobilized by atmospheric pressure glow discharge (APGD) treatment using argon as the discharge gas. The hydrophilicity and chemical changes on the IOL surface were characterized by static water contact angle and X-ray photoelectron spectroscopy to confirm the covalent binding of PEG. The morphology of the IOL surface was observed under field emission scanning electron microscopy and atomic force microscopy. The surface biocompatibility was evaluated by adhesion experiments with platelets, macrophages, and lens epithelial cells (LECs) in vitro. The results revealed that the anterior surface of the PEG-grafted IOL displayed significantly and permanently improved hydrophilicity. Cell repellency was observed, especially in the PEG-modified IOL group, which resisted the attachment of platelets, macrophages and LECs. Moreover, the spread and growth of cells were suppressed, which may be attributed to the steric stabilization force and chain mobility effect of the modified PEG. All of these results indicated that hydrophobic acrylic IOLs can be hydrophilic modified by PEG through APGD treatment in a convenient and continuous manner which will provide advantages for further industrial applications.

  3. Comparisons Between Allogeneic Peripheral Blood Stem Cell Transplantation and Allogeneic Bone Marrow Transplantation in Adult Hematologic Disease: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Yi-Chang Liu

    2003-11-01

    Full Text Available This retrospective study compared the outcomes in 32 adult patients with hematologic diseases (acute myeloid leukemia, acute lymphoblastic leukemia, chronic myeloid leukemia, myelodysplastic syndrome, severe aplastic anemia who received allogeneic bone marrow transplantation (BMT, n = 14; median age, 28 years or allogeneic peripheral blood stem cell transplantation (PBSCT, n = 18; median age, 29 years from human leukocyte antigen-identical sibling donors. Median follow-up was 58 months in BMT recipients and 18 months in PBSCT recipients. Neutrophil (median, Day 8 vs Day 13, p < 0.001 and platelet engraftment (median, Day 9 vs Day 17, p < 0.001 was faster in the PBSCT group than in the BMT group. Patients receiving PBSCT required less platelet transfusion than those receiving BMT (median, 54 units vs 144 units, p < 0.001, but there was no significant difference in red cell transfusion. At 100 days, there was no difference in the incidence of acute graft-versus-host disease (GVHD (42.9% vs 33.3%, p = 0.72 or grade II-IV acute GVHD (14.3% vs 5.6%, p = 0.57, and there was no difference in the cumulative incidence of chronic GVHD (20% vs 33.3%, p = 0.67. No chronic GVHD was noted in any relapsed patients (BMT, 5; PBSCT, 3, and no patients with chronic GVHD during follow-up had a relapse. Relapse was the most frequent cause of death in both groups (BMT, 5/9, 55.6%; PBSCT, 3/4, 75%; p = 0.25; all relapses occurred within 1 year after transplantation. Overall survival was significantly better in the PBSCT group (35.7% vs 77.8%, p = 0.029, but this difference was lost if only hematologic malignancies were analyzed (30.8% vs 63.6%, p = 0.20. Our results are similar to those reported previously, with faster neutrophil and platelet engraftment and less severe acute GVHD and extensive chronic GVHD with PBSCT. Allogeneic PBSCT is a feasible and beneficial alternative to allogeneic BMT in adult hematologic disease.

  4. Optical integration of Pancharatnam-Berry phase lens and dynamical phase lens

    International Nuclear Information System (INIS)

    Ke, Yougang; Liu, Yachao; Zhou, Junxiao; Liu, Yuanyuan; Luo, Hailu; Wen, Shuangchun

    2016-01-01

    In the optical system, most elements such as lens, prism, and optical fiber are made of silica glass. Therefore, integrating Pancharatnam-Berry phase elements into silica glass has potential applications in the optical system. In this paper, we take a lens, for example, which integrates a Pancharatnam-Berry phase lens into a conventional plano-convex lens. The spin states and positions of focal points can be modulated by controlling the polarization states of the incident beam. The proposed lens has a high transmission efficiency, and thereby acts as a simple and powerful tool to manipulate spin photons. Furthermore, the method can be conveniently extended to the optical fiber and laser cavity, and may provide a route to the design of the spin-photonic devices.

  5. Converging or Diverging Lens?

    Science.gov (United States)

    Branca, Mario

    2013-01-01

    Why does a lens magnify? Why does it shrink objects? Why does this happen? The activities that we propose here are useful in helping us to understand how lenses work, and they show that the same lens can have different magnification capabilities. A converging lens can also act as a diverging lens. (Contains 4 figures.)

  6. [Multifocal phakic intraocular lens implant to correct presbyopia].

    Science.gov (United States)

    Baikoff, G; Matach, G; Fontaine, A; Ferraz, C; Spera, C

    2005-03-01

    Presbyopic surgery is considered as the new frontier in refractive surgery. Different solutions are proposed: myopization of one eye, insertion of an accommodative crystalline lens, scleral surgery, the effects of which are still unknown, and finally multifocal phakic implants. We therefore decided to undertake a prospective study under the Huriet law to determine its efficacy and specify the conditions required for an anterior chamber multifocal phakic implant. Fifty-five eyes of 33 patients received an anterior chamber foldable multifocal phakic implant. Twenty-one females and 12 males underwent surgery. Initial refraction was between -5D and +5D. The implant's single addition was +2.50. Recuperating a distant uncorrected visual acuity of 0.6 or better and near uncorrected vision of Parinaud 3 or better can be considered a very good postoperative result. Average follow-up was 42.6+/-18 weeks. Mean postoperative refraction was -0.12+/-0.51 D. Mean postoperative uncorrected visual acuity was 0.78+/-0.20. Postoperative uncorrected visual acuity was Parinaud 2.3+/-0.6. Eighty-four percent of eyes operated on recuperated 0.6 or better without correction and Parinaud 3 or better without correction. Lenses in four eyes were explanted for different reasons, essentially optical, and no severe anatomical complications were observed. Placing an anterior chamber multifocal phakic implant to correct presbyopia is an effective technique with good predictability and has the advantage of being reversible in case of intolerance, optical parasite effects or undesired complications. Considering the particularity of this surgery, it is imperative to respect very strict inclusion criteria: anterior chamber depth equal to or above 3.1 mm, open angle, endothelial cell count equal to or above 2000 cells/mm2, absence of an incipient cataract or the slightest evidence of macular alteration.

  7. Achieving an early pregnancy following allogeneic uterine transplantation in a rabbit model.

    Science.gov (United States)

    Saso, Srdjan; Petts, Gemma; David, Anna L; Thum, Meen-Yau; Chatterjee, Jayanta; Vicente, Jose S; Marco-Jimenez, Francisco; Corless, David; Boyd, Michael; Noakes, David; Lindsay, Iain; Del Priore, Giuseppe; Ghaem-Maghami, Sadaf; Smith, J Richard

    2015-02-01

    Uterine transplantation (UTx) has been proposed as a treatment option for women diagnosed with absolute uterine factor infertility (AUFI). The goal of UTx remains achieving pregnancy and live birth of a healthy neonate following allogeneic UTx. Our aim was to assess whether fertility was possible following allogeneic uterine transplantation (UTx), when the recipient had demonstrated long-term survival and had been administered immunosuppression. Nine allogeneic UTx in New Zealand White rabbits were performed using a pre-determined protocol. Tacrolimus was the immunosuppressant selected. Embryos were transferred into both cornua of the sole living recipient via a mini-midline laparotomy. The pregnancy was monitored with regular reproductive profiles and serial trans-abdominal ultrasound to measure conceptus growth (gestation sac and crown rump length (CRL)). In the sole surviving doe a gestation sac was visualised on ultrasound from Day 9 (D9) after embryo transfer. Gestation sac diameter and CRL increased from D9 to D16 but by D18 the gestation sac had reduced in size. The fetus was no longer visible, suggesting fetal resorption had occurred. Subsequent scans on D22 and D25 did not demonstrate a gestation sac. Scheduled necropsy on D27 and histopathology confirmed evidence of a gravid uterus and presence of a gestational sac. A single episode of acute rejection occurred on D13. Pregnancy was achieved after rabbit allogeneic UTx but serial ultrasound suggested that fetal demise occurred prior to scheduled necropsy. The study represents only the third example of conception and pregnancy following an animal allogeneic UTx. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Allogeneic radiation chimeras induced in SPF mice

    International Nuclear Information System (INIS)

    Sado, Toshihiko; Kamisaku, Hitoko

    1977-01-01

    During the past two decades much has been learned concerning the immunobiology of bone marrow chimeras induced in experimental animals as well as in man. However, from the basic as well as clinical points of view, there still remain many unsolved questions yet to be resolved. In this presentation, we discussed some of our recent results on the immunobiology of radiation chimeras induced in specific-pathogen-free (SPF) mice. These included the following: (a) contribution of graft versus host reaction (GVHR) as well non- GVHR mediated immunologic mechanism(s) to the expression of immunologic dysfunctions observed in allogeneic and certain semiallogeneic chimeras, (b) existence of immunoregulatory mechanism as a basis for the apparent lack of immunologic reactivity (tolerance) to the host- as well as to the donor-type alloantigens in situ in successful allogeneic bone marrow chimeras, and (c) the effect of microflora of the environment on the stability of such immunoregulatory mechanisms and its possible mechanism of action. (auth.)

  9. Radiation therapy for retinoblastoma: comparison of results with lens-sparing versus lateral beam techniques

    International Nuclear Information System (INIS)

    McCormick, B.; Ellsworth, R.; Abramson, D.; Haik, B.; Tome, M.; Grabowski, E.; LoSasso, T.

    1988-01-01

    From 1979 through 1986, 170 children were seen at our institution diagnosed with retinoblastoma. Sixty-six of the children with involvement of 121 eyes, were referred for definitive external beam radiation to one or both eyes. During the study period, two distinct radiation techniques were used. From 1980 through mid-1984, a lens-sparing technique included an anterior electron beam with a contact lens mounted lead shield, combined with a lateral field, was used. Since mid-1984, a modified lateral beam technique has been used, mixing lateral electrons and superior and inferior lateral oblique split beam wedged photons. Doses prescribed were similar for both techniques, ranging from 3,850 to 5,000 cGy in 4 to 5 weeks. The lens-sparing and the modified lateral techniques are compared for local control. For eyes with Group I through III disease, the lens-sparing technique resulted in local control in 33% of the eyes treated, where the modified lateral technique controlled 83% of the eyes treated (p = .006). Mean time to relapse was identical in both groups, that is 24 and 26 months respectively. Most relapses were successfully treated with further local therapy, including laser or cryosurgery, or 60Co plaques. Five eyes required enucleation following initial treatment with the lens-sparing technique, but none thus far with the lateral beam technique. For eyes with Group IV and V disease, no significant differences were found between the two techniques in terms of local control or eventual need for enucleation. With a mean follow-up time of 33 months for the entire group, the 4-year survival is 93%. Two of the 4 deaths are due to second primary tumor, and all 4 have occurred in the lens-sparing group. Because follow-up time is more limited in the lateral beam group, this is not statistically significant and direct survival comparisons are premature

  10. Preoperative Acute Normovolemic Hemodilution for Minimizing Allogeneic Blood Transfusion: A Meta-Analysis.

    Science.gov (United States)

    Zhou, Xuelong; Zhang, Chenjing; Wang, Yin; Yu, Lina; Yan, Min

    2015-12-01

    Previous studies have evaluated the efficacy of preoperative acute normovolemic hemodilution (PANH) in reducing the need for allogeneic blood transfusion. However, the results to date have been controversial. In this study, we sought to reassess the efficacy and safety of PANH based on newly emerging evidence. Medline, EMBASE, ISI Web of Knowledge, and Cochrane Central Register of Controlled Trials databases were searched using the key words "hemodilution," "autotransfusion," or "hemorrhage" to retrieve all randomized controlled trials examining the benefits of PANH compared with control patients not undergoing PANH in any type of surgery. Sixty-three studies involving 3819 patients were identified. The risk of requiring an allogeneic blood transfusion and the overall volume of allogeneic red blood cell transfused during the perioperative period were reduced in the PANH group compared with the control group (relative risk, 0.74; 95% confidence interval, 0.63 to 0.88; P = 0.0006; weighted mean difference, -0.94 units; 95% confidence interval, -1.27 to -0.61 units; P transfusion. Perioperative blood loss, adverse events, and the length of hospitalization were comparable between these groups. Although these results suggest that PANH is effective in reducing allogeneic blood transfusion, we identified significant heterogeneity and publication bias, which raises concerns about the true efficacy of PANH.

  11. Foreign Body Embedded in Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Shmuel Graffi

    2012-01-01

    Full Text Available Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by an external approach without utilizing a magnet. The patient's final outcome was favorable. Discussion. The above is a rare clinical situation, which is impossible to detect on slit-lamp examination without a gonioscopic view. Proper imaging and a specific management are mandatory in order to achieve favorable outcome.

  12. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  13. Analysis on shift and rotation of intraocular lens after phakic collamer lens implantation

    Directory of Open Access Journals (Sweden)

    Yuan-Yuan Lu

    2016-05-01

    Full Text Available Recently, the incidence of myopia increases year by year. The effectiveness of refractive surgery for the correction of ametropia is widely recognized with rapid development of ophthalmic microsurgery. The laser in situ keratomileusis(LASIKhas been accepted as a regular refractive surgery technique to correct mild and moderate myopia. However, it shows inadequacy in ability to correct high refractive errors, and in patients with thin cornea and keratoconus. In 1993, Staar Surgical(A.G. Nidauintroduced a modified intraocular collamer lens(ICLfor the correction of high myopia, which emerged as a safe and effective operation for moderate or high myopia gradually. Although it has already been proved that ICL has safety and efficacy for the correction of high myopia, several studies reported dislocation and rotation of ICL after implantation, which led decreased vision and poor satisfaction. In severe cases, secondary glaucoma, anterior subcapsular cataract happened consequentially. These potential complications have drawn more and more attention by the majority of physicians and scholars. This paper aims to discuss the potential cause of shift and rotation of ICLs after implantation.

  14. Microscope-Integrated Intraoperative Ultrahigh-Speed Swept-Source Optical Coherence Tomography for Widefield Retinal and Anterior Segment Imaging.

    Science.gov (United States)

    Lu, Chen D; Waheed, Nadia K; Witkin, Andre; Baumal, Caroline R; Liu, Jonathan J; Potsaid, Benjamin; Joseph, Anthony; Jayaraman, Vijaysekhar; Cable, Alex; Chan, Kinpui; Duker, Jay S; Fujimoto, James G

    2018-02-01

    To demonstrate the feasibility of retinal and anterior segment intraoperative widefield imaging using an ultrahigh-speed, swept-source optical coherence tomography (SS-OCT) surgical microscope attachment. A prototype post-objective SS-OCT using a 1,050-nm wavelength, 400 kHz A-scan rate, vertical cavity surface-emitting laser (VCSEL) light source was integrated to a commercial ophthalmic surgical microscope after the objective. Each widefield OCT data set was acquired in 3 seconds (1,000 × 1,000 A-scans, 12 × 12 mm 2 for retina and 10 × 10 mm 2 for anterior segment). Intraoperative SS-OCT was performed in 20 eyes of 20 patients. In six of seven membrane peels and five of seven rhegmatogenous retinal detachment repair surgeries, widefield retinal imaging enabled evaluation pre- and postoperatively. In all seven cataract cases, anterior imaging evaluated the integrity of the posterior lens capsule. Ultrahigh-speed SS-OCT enables widefield intraoperative viewing in the posterior and anterior eye. Widefield imaging visualizes ocular structures and pathology without requiring OCT realignment. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:94-102.]. Copyright 2018, SLACK Incorporated.

  15. Allogeneic cellular immunotherapy for chronic B-cell leukemia

    NARCIS (Netherlands)

    Hoogendoorn, Mels

    2007-01-01

    Allogeneic stem cell transplantation (SCT) following reduced-intensity conditioning (RIC) as treatment modality has curative potential in patients suffering from chronic lymphocytic leukemia (CLL) or mantle cell lymphoma (MCL), illustrating susceptibility of these leukemic cells for the

  16. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  17. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    Science.gov (United States)

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p ultrasound, respectively (p power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  18. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    Science.gov (United States)

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  19. Evaluation of diminished microbial contamination in handling of a novel daily disposable flat pack contact lens.

    Science.gov (United States)

    Nomachi, Miya; Sakanishi, Kotaro; Ichijima, Hideji; Cavanagh, H Dwight

    2013-05-01

    To evaluate the efficacy of a novel daily disposable (DD) flat package in regard to microbial contamination on the anterior and posterior surfaces of a contact lens (CL) during handling of the lens for insertion. Four kinds of commercially available general blister-packed daily disposable contact lenses (DD CLs) as controls and a novel Magic 1-day Menicon Flat Pack as a test lens were used for this in vitro study. Lenses were removed from their packages using fingers coated with fluorescein 3 to 5 μm beads or an approximately 7×10(2) to 2×10(3) colony-forming unit (CFU)/mL Staphylococcus aureus suspension. The transfer of fluorescein beads to the surface of the lenses was then observed by fluorescence microscopy. Microbial contamination on the lenses was observed by light microscopy after a 2-day incubation period; and, the number of colonies isolated from the contaminated lenses was determined after 4 days of incubation. The number of fluorescein beads on the Magic lens was significantly less (p<0.05) than that of the general blister-packed control lenses. Adherence of microbial colonies was observed on both inner and outer surfaces of general blister-packed lenses, whereas no colony formation was found on the inner surface of the Magic lens, and the lowest bacterial adherence was observed for the Magic lens. The data demonstrated that placement of the Magic DD lens onto the eye is accompanied by diminished microbial contamination compared with general blister-packed DD CLs. Eye care professionals; however, should instruct patients to comply with intended use of DD CLs to prevent CL-associated microbial keratitis. In all cases, hand washing is mandated prelens insertion.

  20. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  1. Peripheral Defocus of the Monkey Crystalline Lens With Accommodation in a Lens Stretcher

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; Ruggeri, Marco; Ho, Arthur; Gonzalez, Alex; Rowaan, Cor; Bernal, Andres; Arrieta, Esdras; Parel, Jean-Marie

    2018-01-01

    Purpose To characterize the peripheral defocus of the monkey crystalline lens and its changes with accommodation. Methods Experiments were performed on 15 lenses from 11 cynomolgus monkey eyes (age: 3.8–12.4 years, postmortem time: 33.5 ± 15.3 hours). The tissue was mounted in a motorized lens stretcher to allow for measurements of the lens in the accommodated (unstretched) and unaccommodated (stretched) states. A custom-built combined laser ray tracing and optical coherence tomography system was used to measure the paraxial on-axis and off-axis lens power for delivery angles ranging from −20° to +20° (in air). For each delivery angle, peripheral defocus was quantified as the difference between paraxial off-axis and on-axis power. The peripheral defocus of the lens was compared in the unstretched and stretched states. Results On average, the paraxial on-axis lens power was 52.0 ± 3.4 D in the unstretched state and 32.5 ± 5.1 D in the stretched state. In both states, the lens power increased with increasing delivery angle. From 0° to +20°, the relative peripheral lens power increased by 10.7 ± 1.4 D in the unstretched state and 7.5 ± 1.6 D in the stretched state. The change in field curvature with accommodation was statistically significant (P lens has greater curvature or relative peripheral power. Conclusions The cynomolgus monkey lens has significant accommodation-dependent curvature of field, which suggests that the lens asserts a significant contribution to the peripheral optical performance of the eye that also varies with the state of accommodation.

  2. Allogeneic mesenchymal precursor cells (MPCs): an innovative approach to treating advanced heart failure.

    Science.gov (United States)

    Westerdahl, Daniel E; Chang, David H; Hamilton, Michele A; Nakamura, Mamoo; Henry, Timothy D

    2016-09-01

    Over 37 million people worldwide are living with Heart Failure (HF). Advancements in medical therapy have improved mortality primarily by slowing the progression of left ventricular dysfunction and debilitating symptoms. Ultimately, heart transplantation, durable mechanical circulatory support (MCS), or palliative care are the only options for patients with end-stage HF. Regenerative therapies offer an innovative approach, focused on reversing myocardial dysfunction and restoring healthy myocardial tissue. Initial clinical trials using autologous (self-donated) bone marrow mononuclear cells (BMMCs) demonstrated excellent safety, but only modest efficacy. Challenges with autologous stem cells include reduced quality and efficacy with increased patient age. The use of allogeneic mesenchymal precursor cells (MPCs) offers an "off the shelf" therapy, with consistent potency and less variability than autologous cells. Preclinical and initial clinical trials with allogeneic MPCs have been encouraging, providing the support for a large ongoing Phase III trial-DREAM-HF. We provide a comprehensive review of preclinical and clinical data supporting MPCs as a therapeutic option for HF patients. The current data suggest allogeneic MPCs are a promising therapy for HF patients. The results of DREAM-HF will determine whether allogeneic MPCs can decrease major adverse clinical events (MACE) in advanced HF patients.

  3. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.

  4. Comparison of clear lens extraction and collamer lens implantation in high myopia

    Directory of Open Access Journals (Sweden)

    Ahmed M Emarah

    2010-05-01

    Full Text Available Ahmed M Emarah, Mostafa A El-Helw, Hazem M YassinCairo University, Cairo, EgyptAim: To compare the outcomes of clear lens extraction and collamer lens implantation in high myopia.Patients and methods: Myopic patients younger than 40 years old with more than 12 diopters of myopia or who were not fit for laser-assisted in situ keratomileusis were included. Group 1 comprised patients undergoing clear lens extraction and Group 2 patients received the Visian implantable collamer lens. Outcome and complications were evaluated.Results: Postoperative best corrected visual acuity was -0.61 ± 0.18 in Group 1 and 0.79 ± 0.16 in Group 2. In Group 1, 71.4% achieved a postoperative uncorrected visual acuity better than the preoperative best corrected visual acuity, while only 51.8% patients achieved this in Group 2. Intraocular pressure decreased by 12.55% in Group 1, and increased by 15.11% in Group 2. Corneal endothelial cell density decreased by 4.47% in Group 1 and decreased by 5.67% in Group 2. Posterior capsule opacification occurred in Group 1. In Group 2, lens opacification occurred in 11.11%, significant pigment dispersion in 3.7%, and pupillary block glaucoma in 3.7%.Conclusion: Clear lens extraction presents less of a financial load up front, and less likelihood of the need for a secondary intervention in the future. Clear lens extraction is a more viable solution in developing countries with limited financial resources.Keywords: clear lens extraction, implantable collamer lens, myopia

  5. Outcomes of allogeneic hematopoietic stem cell transplantation for lymphomas: a single-institution experience

    Directory of Open Access Journals (Sweden)

    Mira Romany Massoud

    Full Text Available ABSTRACT Introduction: Allogeneic hematopoietic stem cell transplantation offers the opportunity for extended survival in patients with Hodgkin's and non-Hodgkin lymphomas who relapsed after, or were deemed ineligible for, autologous transplantation. This study reports the cumulative experience of a single center over the past 14 years aiming to define the impact of patient, disease, and transplant-related characteristics on outcomes. Methods: All patients with histologically confirmed diagnosis of Hodgkin's or non-Hodgkin lymphomas who received allogeneic transplantation from 2000 to 2014 were retrospectively studied. Results: Forty-one patients were reviewed: 10 (24% had Hodgkin's and 31 (76% had non-Hodgkin lymphomas. The median age was 50 years and 23 (56% were male. The majority of patients (68% had had a prior autologous transplantation. At the time of allogeneic transplantation, 18 (43% patients were in complete and seven (17% were in partial remission. Most (95% patients received reduced-intensity conditioning, 49% received matched sibling donor grafts, 24% matched-unrelated donor grafts, and 27% received double umbilical cord blood grafts. The 100-day treatment-related mortality rate was 12%. After a median duration of follow up of 17.1 months, the median progression-free and overall survival was 40.5 and 95.8 months, respectively. On multivariate analysis, patients who had active disease at the time of transplant had inferior survival. Conclusions: Allogeneic transplantation results extend survival in selected patients with relapsed/refractory Hodgkin's and non-Hodgkin lymphomas with low treatment-related mortality. Patients who have active disease at the time of allogeneic transplantation have poor outcomes.

  6. Changes in lens stiffness due to capsular opacification in accommodative lens refilling

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Sharma, Prashant K.; van Kooten, Theo G.; Koopmans, Steven A.

    Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been

  7. Comparative analysis of autologous blood transfusion and allogeneic blood transfusion in surgical patients

    OpenAIRE

    Long, Miao-Yun; Liu, Zhong-Han; Zhu, Jian-Guang

    2014-01-01

    Objective: To investigate application effects of autologous blood transfusion and allogeneic blood transfusion in surgically treated patients receiving spine surgery, abdomen surgery and ectopic pregnancy surgery. Methods: 130 patients who would undergo selective operations were divided into autologous transfusion group and allogeneic transfusion group. Both groups received the same anesthesia, and there was no significant difference in transfusion volume or fluid infusion volume. Results: Th...

  8. A standardized multidisciplinary approach reduces the use of allogeneic blood products in patients undergoing cardiac surgery

    NARCIS (Netherlands)

    van der Linden, P.; de Hert, S.; Daper, A.; Trenchant, A.; Jacobs, D.; de Boelpaepe, C.; Kimbimbi, P.; Defrance, P.; Simoens, G.

    2001-01-01

    PURPOSE: Individual and institutional practices remain an independent predictor factor for allogeneic blood transfusion. Application of a standardized multidisciplinary transfusion strategy should reduce the use of allogeneic blood transfusion in major surgical patients. METHODS: This prospective

  9. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  10. Damage to lens fiber cells causes TRPV4-dependent Src family kinase activation in the epithelium.

    Science.gov (United States)

    Shahidullah, M; Mandal, A; Delamere, N A

    2015-11-01

    The bulk of the lens consists of tightly packed fiber cells. Because mature lens fibers lack mitochondria and other organelles, lens homeostasis relies on a monolayer of epithelial cells at the anterior surface. The detection of various signaling pathways in lens epithelial cells suggests they respond to stimuli that influence lens function. Focusing on Src Family Kinases (SFKs) and Transient Receptor Potential Vanilloid 4 (TRPV4), we tested whether the epithelium can sense and respond to an event that occurs in fiber mass. The pig lens was subjected to localized freeze-thaw (FT) damage to fibers at posterior pole then the lens was incubated for 1-10 min in Krebs solution at 37 °C. Transient SFK activation in the epithelium was detectable at 1 min. Using a western blot approach, the ion channel TRPV4 was detected in the epithelium but was sparse or absent in fiber cells. Even though TRPV4 expression appears low at the actual site of FT damage to the fibers, SFK activation in the epithelium was suppressed in lenses subjected to FT damage then incubated with the TRPV4 antagonist HC067047 (10 μM). Na,K-ATPase activity was examined because previous studies report changes of Na,K-ATPase activity associated with SFK activation. Na,K-ATPase activity doubled in the epithelium removed from FT-damaged lenses and the response was prevented by HC067047 or the SFK inhibitor PP2 (10 μM). Similar changes were observed in response to fiber damage caused by injection of 5 μl hyperosmotic NaCl or mannitol solution beneath the surface of the posterior pole. The findings point to a TRPV4-dependent mechanism that enables the epithelial cells to detect remote damage in the fiber mass and respond within minutes by activating SFK and increasing Na,K-ATPase activity. Because TRPV4 channels are mechanosensitive, we speculate they may be stimulated by swelling of the lens structure caused by damage to the fibers. Increased Na,K-ATPase activity gives the lens greater capacity to

  11. Association of lens vault with narrow angles among different ethnic groups.

    Science.gov (United States)

    Lee, Roland Y; Huang, Guofu; Cui, Qi N; He, Mingguang; Porco, Travis C; Lin, Shan C

    2012-06-01

    To compare lens vault between open-angle and narrow-angle eyes in African-, Caucasian-, Hispanic-, Chinese- and Filipino-Americans. In this prospective study, 436 patients with open angle and narrow angle based on the Shaffer gonioscopic grading classification underwent anterior-segment optical coherence tomography. The Zhongshan Angle Assessment Program was used to calculate lens vault. The narrow-angle group included 32 Chinese-Americans, 22 Filipino-Americans, 26 African-Americans, 24 Hispanic-Americans and 73 Caucasian-Americans. The open-angle group included 56 Chinese-Americans, 29 Filipino-Americans, 45 African-Americans, 27 Hispanic-Americans and 102 Caucasian-Americans. Linear mixed effect regression models, accounting for the use of both eyes and adjusting for age, sex, pupil diameter and spherical equivalent, were used to test for the ethnicity and angle coefficients. Tukey's multiple comparison test was used for pairwise comparisons among the open-angle racial groups. Significant difference in lens vault was found among the open-angle racial groups (P = 0.022). For the open-angle patients, mean values for the lens vault measurements were 265 ± 288 µm for Chinese-Americans, 431 ± 248 µm for Caucasian-Americans, 302 ± 213 µm for Filipino-Americans, 304 ± 263 µm for Hispanic-Americans and 200 ± 237 µm for African-Americans. Using Tukey's multiple comparison for pairwise comparisons among the open-angle racial groups, a significant difference was found between African-American and Caucasian-Americans groups (P values for the rest of the pairwise comparisons were not statistically significant. No significant difference was found among the narrow-angle racial groups (P = 0.14). Comparison between the open angle and narrow angle within each racial group revealed significant difference for all racial groups (P < 0.05). Among all the ethnicities included in this study, narrow-angle eyes have greater lens vault compared to open

  12. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  13. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    International Nuclear Information System (INIS)

    Park, J.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  14. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  15. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  16. Allogeneic radiation chimeras respond to TNP-modified donor and host targets

    International Nuclear Information System (INIS)

    Lattime, E.C.; Gershon, H.E.; Stutman, O.

    1980-01-01

    Tolerance to major histocompatibility antigens as well as the ability to mount a cytotoxic response to hapten-modified cells of bone marrow donor and host origin was studied in allogeneic radiation chimeras. Lethally irradiated (C57BL/6 x DBA/2)F1 hosts reconstituted with anti-Thy 1.2 + C-treated bone marrow from (C57BL/6 x CBA)F1 mice showed tolerance to the MHC antigens of the three parental strains as measured by MLC and CML assay. The chimeras responded normally to unrelated allogeneic cells. Chimeric animals generated a cytotoxic response to hapten-modified cells of both donor (CBA) and host (DBA/2) haplotypes, as well as to C57BL/6, demonstrating that tolerance to the hapten-presenting host haplotype is sufficient to allow a cytotoxic antihapten response, and that processing through a semiallogeneic host environment does not affect the ability to generate a response to hapten in conjunction with self-determinants. Chimeras failed to mount a cytotoxic response to hapten presented on nontolerated allogeneic spleen cells

  17. Evaluation of Descemet’s Membrane Detachment Using Anterior Segment Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Halil Hüseyin Çağatay

    2014-10-01

    Full Text Available We report the use of anterior segment optical coherence tomography (ASOCT in Descemet’s membrane detachment (DMD. A patient who developed DMD after uneventful cataract surgery with posterior chamber lens implantation is presented in this case report. At the follow-up examination after cataract surgery, slit-lamp evaluation showed stromal striae, but it was impossible to diagnose the DMD due to the corneal edema. ASOCT imaging of the cornea revealed a DMD, and the patient underwent intracameral air injection to the anterior chamber through the site which was identified as intact by ASOCT. Follow-up ASOCT imaging revealed the reattachment of the Descemet’s membrane and reduced corneal thickness. If DMD is suspected in any cases, ASOCT can be useful to document and follow the postsurgical detachment of DMD and also to determine the site, configuration, and extent of the DMD, thus guiding the treatment method and monitoring the treatment outcome. (Turk J Ophthalmol 2014; 44: 407-9

  18. Establishment of donor Chimerism Using Allogeneic Bone Marrow with AMP Cell Co-infusion

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-15-1-0234 TITLE: Establishment of donor Chimerism Using Allogeneic Bone Marrow with AMP Cell Co-infusion PRINCIPAL...14/2017 4. TITLE AND SUBTITLE Establishment of donor Chimerism Using Allogeneic Bone Marrow with AMP Cell Co-infusion 5a. CONTRACT NUMBER 5b. GRANT...tolerance induction of all types of allografts. In this study, we investigate whether co-infusion of amnion- derived multipotent progenitor (AMP) cells

  19. Vortex gas lens

    Science.gov (United States)

    Bogdanoff, David W.; Berschauer, Andrew; Parker, Timothy W.; Vickers, Jesse E.

    1989-01-01

    A vortex gas lens concept is presented. Such a lens has a potential power density capability of 10 to the 9th - 10 to the 10th w/sq cm. An experimental prototype was constructed, and the divergence half angle of the exiting beam was measured as a function of the lens operating parameters. Reasonably good agreement is found between the experimental results and theoretical calculations. The expanded beam was observed to be steady, and no strong, potentially beam-degrading jets were found to issue from the ends of the lens. Estimates of random beam deflection angles to be expected due to boundary layer noise are presented; these angles are very small.

  20. Bilateral intraocular lens subluxation secondary to haptic angulation.

    Science.gov (United States)

    Moreno-Montañés, Javier; Fernández-Hortelano, Ana; Caire, Josemaría

    2008-04-01

    An 82-year-old man had uneventful phacoemulsification with bilateral implantation of a hydrophilic acrylic, single-piece intraocular lens (IOL) (ACR6D SE, Laboratoires Cornéal). Five years later, simultaneous and bilateral IOL subluxations occurred. In both eyes, the subluxation was situated on the side of one haptic that had moved forward (temporal area in the right eye and superior area in the left eye). In the right eye, the haptic-capsular bag was entrapped by the pupil and produced endothelial damage. A transscleral suture was placed over and under the subluxated haptic through the anterior and posterior capsules to capture the haptic. The haptic was then sutured to the sclera. No postoperative complications developed. We hypothesize that 10-degree angulated and broad haptic junctions can lead to zonular damage and IOL subluxation.

  1. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user

  2. Comparison of autogeneic and allogeneic natural killer cells immunotherapy on the clinical outcome of recurrent breast cancer

    Directory of Open Access Journals (Sweden)

    Liang S

    2017-08-01

    Full Text Available Shuzhen Liang,1,2 Kecheng Xu,1,2 Lizhi Niu,1,2 Xiaohua Wang,1 Yingqing Liang,1 Mingjie Zhang,3 Jibing Chen,1,2 Mao Lin1,2 1Department of Central Laboratory, Fuda Cancer Hospital, Jinan University School of Medicine, Guangzhou, Guangdong, China; 2Fuda Cancer Institute, Guangzhou, Guangdong, China; 3Hank Bioengineering Co., Ltd, Shenzhen, China Abstract: In the present study, we aimed to compare the clinical outcome of autogeneic and allogeneic natural killer (NK cells immunotherapy for the treatment of recurrent breast cancer. Between July 2016 and February 2017, 36 patients who met the enrollment criteria were randomly assigned to two groups: autogeneic NK cells immunotherapy group (group I, n=18 and allogeneic NK cells immunotherapy group (group II, n=18. The clinical efficacy, quality of life, immune function, circulating tumor cell (CTC level, and other related indicators were evaluated. We found that allogeneic NK cells immunotherapy has better clinical efficacy than autogeneic therapy. Moreover, allogeneic NK cells therapy improves the quality of life, reduces the number of CTCs, reduces carcinoembryonic antigen and cancer antigen 15-3 (CA15-3 expression, and significantly enhances immune function. To our knowledge, this is the first clinical trial to compare the clinical outcome of autogeneic and allogeneic NK cells immunotherapy for recurrent breast cancer. Keywords: clinical outcome, autogeneic, allogeneic, natural killer cells, recurrent breast cancer

  3. Delayed allogeneic skin graft rejection in CD26-deficient mice.

    Science.gov (United States)

    Zhao, Xiangli; Zhang, Kai; Daniel, Peter; Wisbrun, Natali; Fuchs, Hendrik; Fan, Hua

    2018-03-23

    Organ transplantation is an effective therapeutic tool for treating many terminal diseases. However, one of the biggest challenges of transplantation is determining how to achieve the long-term survival of the allogeneic or xenogeneic transplant by, for example, preventing transplant rejection. In the current study, CD26 gene-knockout mice were used to investigate the potential role of CD26/dipeptidyl peptidase-4 (DPPIV) in allogeneic skin graft rejection by tail-skin transplantation. Compared with wild-type (CD26 +/+ ) counterparts, CD26 -/- mice showed reduced necrosis of grafts and delayed graft rejection after skin transplantation. Concentrations of serum IgG, including its subclasses IgG1 and IgG2a, were significantly reduced in CD26 -/- mice during graft rejection. Moreover, after allogeneic skin transplantation, the secretion levels of the cytokines IFN-γ, IL-2, IL-6, IL-4, and IL-13 were significantly reduced, whereas the level of the cytokine IL-10 was increased in the serum of CD26 -/- mice compared with that in the serum of CD26 +/+ mice. Additionally, the concentration of IL-17 in serum and the percentage of cells secreting IL-17 in mouse peripheral blood lymphocytes (MPBLs) were both significantly lower, while the percentage of regulatory T cells (Tregs) was significantly higher in MPBLs of CD26 -/- mice than in those of CD26 +/+ mice. Furthermore, a lower percentage of CD8 + T cells in MPBLs and fewer infiltrated macrophages and T cells in graft tissues of CD26 -/- mice were detected during graft rejection. These results indicate that CD26 is involved in allogeneic skin graft rejection and provides another hint that CD26 deficiency leads to less rejection due to lower activation and proliferation of host immune cells.

  4. Pelvic reconstruction with allogeneic bone graft after tumor resection

    Science.gov (United States)

    Wang, Wei; Bi, Wen Zhi; Yang, Jing; Han, Gang; Jia, Jin Peng

    2013-01-01

    OBJECTIVES : Pelvic reconstruction after tumor resection is challenging. METHODS: A retrospective study had been preformed to compare the outcomes among patients who received pelvic reconstructive surgery with allogeneic bone graft after en bloc resection of pelvic tumors and patients who received en bloc resection only. RESULTS: Patients without reconstruction had significantly lower functional scores at 3 months (10 vs. 15, P = 0.001) and 6 months after surgery (18.5 vs. 22, P = 0.0024), a shorter duration of hospitalization (16 day vs. 40 days, P 0.05). CONCLUSIONS : Pelvic reconstruction with allogeneic bone graft after surgical management of pelvic tumors is associated with satisfactory surgical and functional outcomes. Further clinical studies are required to explore how to select the best reconstruction method. Level of Evidence IV, Case Series. PMID:24453659

  5. Study of the structure of buffalo's eye lens and scleroretinal rim in Tabriz by ultrasonography

    Directory of Open Access Journals (Sweden)

    GH Assadnassab

    2011-05-01

    Full Text Available In this study, ultrasonographic condition of lens and posterior wall of buffalo's eye in Tabriz area were investigated due to their important role in vision and also measurements were made in anterior-posterior axial B-mode display methods. The ultrasonographic images were similar to the images obtained from other particularly the cow. Total thickness of the lens was 1.133 ± 0.052 cm with the thickness being 1.135 ± 0.052 cm in the right eye and 1.132 ± 0.053 cm in the left eye. Thickness of the posterior wall of the right and left eyes were 1.677 ± 0.042 mm and 1.672 ± 0.041 mm respectively with the total thickness of the posterior wall measuring 1.674 ± 0.040 mm. There was no significant difference between the left and right eyes regarding these parameters.

  6. Capsular 'pits' in the human lens.

    OpenAIRE

    Harris, M. L.; Brown, N. A.; Shun-Shin, G. A.; Smith, G. T.

    1992-01-01

    The lens capsule is an atypical basement membrane surrounding the lens epithelial cells and lens fibres which make up the remainder of the human lens. A seemingly unreported morphological change visible in the lens capsule with the biomicroscope is described.

  7. Allogeneic Mesenchymal Stem Cell Treatment Induces Specific Alloantibodies in Horses

    Directory of Open Access Journals (Sweden)

    Sean D. Owens

    2016-01-01

    Full Text Available Background. It is unknown whether horses that receive allogeneic mesenchymal stem cells (MSCs injections develop specific humoral immune response. Our goal was to develop and validate a flow cytometric MSC crossmatch procedure and to determine if horses that received allogeneic MSCs in a clinical setting developed measurable antibodies following MSC administration. Methods. Serum was collected from a total of 19 horses enrolled in 3 different research projects. Horses in the 3 studies all received unmatched allogeneic MSCs. Bone marrow (BM or adipose tissue derived MSCs (ad-MSCs were administered via intravenous, intra-arterial, intratendon, or intraocular routes. Anti-MSCs and anti-bovine serum albumin antibodies were detected via flow cytometry and ELISA, respectively. Results. Overall, anti-MSC antibodies were detected in 37% of the horses. The majority of horses (89% were positive for anti-bovine serum albumin (BSA antibodies prior to and after MSC injection. Finally, there was no correlation between the amount of anti-BSA antibody and the development of anti-MSC antibodies. Conclusion. Anti allo-MSC antibody development was common; however, the significance of these antibodies is unknown. There was no correlation between either the presence or absence of antibodies and the percent antibody binding to MSCs and any adverse reaction to a MSC injection.

  8. Novel therapies and their integration into allogeneic stem cell transplant for chronic lymphocytic leukemia.

    Science.gov (United States)

    Jaglowski, Samantha M; Byrd, John C

    2012-01-01

    Over the past decade, numerous advances have been made in elucidating the biology of and improving treatment for chronic lymphocytic leukemia (CLL). These studies have led to identification of select CLL patient groups that generally have short survival dating from time of treatment or initial disease relapse who benefit from more aggressive therapeutic interventions. Allogeneic transplantation represents the only potentially curative option for CLL, but fully ablative regimens applied in the past have been associated with significant morbidity and mortality. Reduced-intensity preparative regimens has made application of allogeneic transplant to CLL patients much more feasible and increased the number of patients proceeding to this modality. Arising from this has been establishment of guidelines where allogeneic stem cell transplantation should be considered in CLL. Introduction of new targeted therapies with less morbidity, which can produce durable remissions has the potential to redefine where transplantation is initiated in CLL. This review briefly summarizes the field of allogeneic stem cell transplant in CLL and the interface of new therapeutics with this modality. Copyright © 2012 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  9. Anterior and posterior ocular biometry in healthy Chinese subjects: data based on AS-OCT and SS-OCT.

    Directory of Open Access Journals (Sweden)

    Wenbin Huang

    Full Text Available To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects.A total of 148 subjects (270 eyes were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coherence tomography (AS-OCT and swept-source optical coherence tomography (SS-OCT.Compared with male eyes, female eyes had narrower anterior biometric parameters that presented with smaller anterior segment parameters [including anterior chamber depth (ACD, width (ACW, area (ACA, and volume (ACV; (all p<0.001], narrower anterior chamber angle parameters [including angle opening distance (AOD750, trabecular-iris space area (TISA750, and angle recess area (ARA; (all p<0.001], higher iris curvature (ICURV (p = 0.003, and larger lens vaults (LV (p = 0.019. These anterior ocular biometric parameters were correlated with increasing age (p<0.01. Iris thickness (IT750 and iris area (IAREA were associated with age, ACW, and pupil diameter (all p<0.05, while choroidal thickness (CT was associated with age, gender, and axial length (all p<0.05. Univariate regression analysis showed that greater CT was significantly associated with smaller IAREA (p = 0.026.Compared with male eyes, female eyes had narrower anterior biometric parameters that correlated with increasing age, which would be helpful in explaining the higher prevalence of angle closure rates in the female gender and in aging people. Increased CT might be associated with smaller iris area; however, this possibility needs to be investigated in future studies before this conclusion is made.

  10. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  11. Single-centre experience of allogeneic haemopoietic stem cell ...

    African Journals Online (AJOL)

    Allogeneic haemopoietic stem cell transplant (Allo-HSCT) is used to treat a broad but well-defined range of paediatric conditions, most frequently in paediatric oncology for treatment intensification or salvage therapy for acute myeloid leukaemia (AML) and acute lymphoblastic leukaemia (ALL). Allo-HSCT is also indicated in.

  12. On the Feasibility of Utilizing Allogeneic Bone Blocks for Atrophic Maxillary Augmentation

    Directory of Open Access Journals (Sweden)

    Alberto Monje

    2014-01-01

    Full Text Available Purpose. This systematic review was aimed at assessing the feasibility by means of survival rate, histologic analysis, and causes of failure of allogeneic block grafts for augmenting the atrophic maxilla. Material and Methods. A literature search was conducted by one reviewer in several databases. Articles were included in this systematic review if they were human clinical trials in which outcomes of allogeneic bone block grafts were studied by means of survival rate. In addition other factors were extracted in order to assess their influence upon graft failure. Results. Fifteen articles fulfilled the inclusion criteria and subsequently were analyzed in this systematic review. A total of 361 block grafts could be followed 4 to 9 months after the surgery, of which 9 (2.4% failed within 1 month to 2 months after the surgery. Additionally, a weighed mean 4.79 mm (95% CI: 4.51–5.08 horizontal bone gain was computed from 119 grafted sites in 5 studies. Regarding implant cumulative survival rate, the weighed mean was 96.9% (95% CI: 92.8–98.7%, computed from 228 implants over a mean follow-up period of 23.9 months. Histologic analysis showed that allogeneic block grafts behave differently in the early stages of healing when compared to autogenous block grafts. Conclusion. Atrophied maxillary reconstruction with allogeneic bone block grafts represents a reliable option as shown by low block graft failure rate, minimal resorption, and high implant survival rate.

  13. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  14. Antibody responses in allogeneic radiation chimeras

    International Nuclear Information System (INIS)

    Coico, R.F.

    1982-01-01

    The construction of long-lived allogeneic radiation chimeras, free of graft-versus-host disease, has been achieved using serologic elimination of Thy 1 + cells from donor bone marrow. Humoral immune function was not restored in these animals as evidenced by lack of primary antibody responses to a T cell-dependent antigen, namely, sheep erythrocytes (SRBC) both in vivo and in vitro. No evidence for a suppressor cell-mediated mechanism was found. Using separated chimera spleen cell populations and specific helper cell soluble mediators, the functional capabilities of chimera B cells, T cells, and macrophages were assessed. These findings suggested that the failure of chimeras to produce antibody is not the result of impaired B cell, T cell, or macrophage function, but rather, that it is due to ineffective cellular interactions. Physiologic cellular interactions depend upon the sharing of major histocompatibility complex (MHC) determinants between interacting cells. However, the self-recognition repertoire of developing T cells may be influenced by the environment which these cells differentiate such that they learn to recognize host MHC determinants as self. These findings support the interpretation that the immunologic hyporeactivity of allogeneic bone marrow chimeras reflects the role of the host environment in restricting the interactive capabilities of donor-derived cells

  15. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  16. Alternative allogeneic donor sources for transplantation for childhood diseases: unrelated cord blood and haploidentical family donors.

    Science.gov (United States)

    Cairo, Mitchell S; Rocha, Vanderson; Gluckman, Eliane; Hale, Gregory; Wagner, John

    2008-01-01

    Allogeneic stem cell transplantation has been demonstrated to be curative in a wide variety of pediatric malignant and nonmalignant diseases, and can be traced back over 50 years ago to the original report of Thomas et al. HLA matched sibling donors have been the gold standard for pediatric recipients requiring allogeneic donors for both nonmalignant and malignant conditions. However, only 25% of potential pediatric recipients possesses an HLA-matched sibling donor, and the frequency is even less in those with genetic nonmalignant conditions because of genetically affected other siblings within the family. Therefore, 75% to 90% of potential pediatric recipients require alternative allogeneic donor cells for treatment of their underlying conditions. Potential alternative allogeneic donor sources include unrelated cord blood donors, unrelated adult donors, and haploidentical family donors. In this article we review the experience of both unrelated cord blood donor and haploidentical family donor transplants in selected pediatric malignant and nonmalignant conditions.

  17. Effect of allogenic thymic cells on radioleukaemogenesis in AKR-T1ALD mice

    International Nuclear Information System (INIS)

    Legrand, E.; Sankar-Mistry, P.; Kressmann, M.C.

    1975-01-01

    When AKR mice are irradiated with a sub-lethal dose (4 times 175 R), thymic lymphosarcomas (L.S.) occur earlier than in controls. This accelerated leukaemogenesis is not inhibited by syngenic restoration with bone marrows cells (BM). Using the AKR/T1ALD substrain which bears 38 chromosomes with 1 metacentric markers, it has been shown that AKR radio-chimaeras restored by T1ALD BM developed two kinds of L.S.: early (radiation-induced) L.S. originating mainly from host cells surviving irradiation and late L.S. from donor cells. The experiments were to investigate the potential influence of normal allogenic thymic cells, with or without syngenic B.M., on the incidence, latency and origin of LS appearing in irradiated AKR recipients. Adding C3H allogenic thymic cells to syngenic B.M. increases the percentage of early L.S. whose latencies are unchanged. Besides, when C3H thymic cells are injected to irradiated controls without syngenic B.M. cells, L.S. are seen to occur significantly earlier than in just the irradiated animals alone. In radio-chimaeras restored by allogenic thymic cells and syngenic B.M., except in one case, all the L.S. were seen to originate from B.M. cells. The interpretation of these results depends on the possible role of allogenic thymic cells on host cells surviving the irradiation, or the exogeneous B.M. In the first case, allogenic thymocytes could induce a graft versus host reaction increasing the post-irradiation depletion of lymphoid system and hastening thymic endoregeneration which is supposed to be the first step towards leukaemogenesis. The second hypothesis, which seems the most likely, would be that C1H thymic cells could selectively act on host cells surviving irradiation and enhance the differenciation of haemopoietic precursors at the expense of the lymphoid cells [fr

  18. Age, Gender, Biometry, Refractive Error, and the Anterior Chamber Angle among Alaskan Eskimos

    Science.gov (United States)

    Wojciechowski, Robert; Congdon, Nathan; Anninger, William; Broman, Aimee Teo

    2011-01-01

    Background The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency. Methods A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161–7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects. Results Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond. Conclusions Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher

  19. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  20. Specific Factors Influence the Success of Autologous and Allogeneic Hematopoietic Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Thissiane L. Gonçalves

    2009-01-01

    Full Text Available Successful hematopoietic stem cell transplantation (HSCT, both autologous and allogeneic, requires a rapid and durable engraftment, with neutrophil (>500/µL and platelet (>20,000/µL reconstitution. Factors influencing engraftment after autologous or allogeneic HSCT were investigated in 65 patients: 25 autologous peripheral stem cell transplantation (PBSCT and 40 allogeneic bone marrow transplantation (BMT patients. The major factor affecting engraftment was the graft source for HSCT. Neutrophil and platelet recovery were more rapid in autologous PBSCT than in allogeneic BMT [neutrophil occurring in median on day 10.00 (09.00/11.00 and 19.00 (16.00/23.00 and platelet on day 11.00 (10.00/13.00 and 21.00 (18.00/25.00, respectively; p < 0.0001]. The type of disease also affected engraftment, where multiple myeloma (MM and lymphoma showed faster engraftment when compared with leukemia, syndrome myelodysplastic (SMD and aplastic anemia (AA and MM presented the best overall survival (OS in a period of 12 months. Other factors included the drug used in the conditioning regimen (CR, where CBV, melphalan (M-200 and FluCy showed faster engraftment and M-200 presented the best OS, in a period of 12 months and age, where 50–59 years demonstrated faster engraftment. Sex did not influence neutrophil and platelet recovery.

  1. Prolonged Survival of Subcutaneous Allogeneic Islet Graft by Donor Chimerism without Immunosuppressive Treatment

    Directory of Open Access Journals (Sweden)

    Brend Ray-Sea Hsu

    2017-01-01

    Full Text Available The aim of this study was to investigate whether tolerance-induced protection of islets in the renal subcapsular space can also prevent subcutaneous allogeneic islets from being rejected. We used bone marrow stem cells from C57BL/6 (H2b mice to construct donor chimerism in conditioned diabetic BALB/c (H2d mice and investigated the effect of donor chimerism on engraftment and survival of subcutaneously transplanted allogeneic islets in streptozotocin-induced diabetic mice. We also studied the anti-inflammatory effect of mesenchymal stem cell on islet engraftment. Full but not low-grade or no donor chimerism was associated with successful engraftment of allogeneic islets and restoration of normoglycemia in the treated diabetic mice. The temporary hyperglycemia was 11 ± 1 versus 19 ± 5 days (p<0.05 for the mice with full donor chimerism with transplanted islets in the renal subcapsular space versus the subcutaneous space, respectively. Cotransplantation of mesenchymal stem cell did not enhance alloislet engraftment. Full multilineage donor chimerism was associated with a higher transient expansion of CD11b+ and Gr-1+ myeloid progenitor cells and effector memory CD4 and CD8 T cells. In conclusion, full donor chimerism protected both renal subcapsular and subcutaneous allogeneic islets in this rodent transplantation model.

  2. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    Science.gov (United States)

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  3. Surgical management of anterior chamber epithelial cysts.

    Science.gov (United States)

    Haller, Julia A; Stark, Walter J; Azab, Amr; Thomsen, Robert W; Gottsch, John D

    2003-03-01

    To review management strategies for treatment of anterior chamber epithelial cysts. Retrospective review of consecutive interventional case series. Charts of patients treated for epithelial ingrowth over a 10-year period by a single surgeon were reviewed. Cases of anterior chamber epithelial cysts were identified and recorded, including details of ocular history, preoperative and postoperative acuity, intraocular pressure (IOP), and ocular examination, type of surgical intervention, and details of further procedures performed. Seven eyes with epithelial cysts were identified. Patient age ranged from 1.5 to 53 years at presentation. Four patients were children. In four eyes, cysts were secondary to trauma, one case was presumably congenital, one case developed after corneal perforation in an eye with Terrien's marginal degeneration, and one case developed after penetrating keratoplasty (PK). Three eyes were treated with vitrectomy, en bloc resection of the cyst and associated tissue, fluid-air exchange and cryotherapy. The last four eyes were treated with a new conservative strategy of cyst aspiration (three cases) or local excision (one keratin "pearl" cyst), and endolaser photocoagulation of the collapsed cyst wall/base. All epithelial tissue was successfully eradicated by clinical criteria; one case required repeat excision (follow-up, 9 to 78 months, mean 45). Two eyes required later surgery for elevated IOP, two for cataract extraction and one for repeat PK. Final visual acuity ranged from 20/20 to hand motions, depending on associated ocular damage. Best-corrected visual results were obtained in the more conservatively managed eyes. Anterior chamber epithelial cysts can be managed conservatively in selected cases with good results. This strategy may be particularly useful in children's eyes, where preservation of the lens, iris, and other structures may facilitate amblyopia management. Copyright 2003 by Elsevier Science Inc.

  4. Cytogenetic conversion following allogeneic bone marrow transplantation for advanced chronic myelogenous leukemia

    International Nuclear Information System (INIS)

    McGlave, P.B.; Miller, W.J.; Hurd, D.D.; Arthur, D.C.; Kim, T.

    1981-01-01

    We performed a pilot study to test the effectiveness of allogeneic bone marrow transplantation in the treatment of chronic myelogenous leukemia. Five patients in the advanced stages of chronic myelogenous leukemia (four in blast crisis, one in accelerated phase) with abnormal chromosomes underwent matched-sibling allogeneic bone marrow transplantation after preparation with busulfan, vincristine, cyclophosphamide, and fractionated total body irradiation. Engraftment and conversion to normal chromosome patterns after transplantation occurred in all five patients. None of the patients reverted to an abnormal chromosome pattern or demonstrated clinical or hematologic evidence of recurrent disease during the course of this study; however, longest survival from transplant was 248 days. Allogeneic bone marrow transplantation can eradicate the abnormal clone even in far advanced chronic myelogenous leukemia and can provide normal hematopoiesis. We suggest that clinical complications of chemotherapeutic toxicity and infection were responsible for the short survival in this group of patients, and that these complications could be decreased by performing transplantation in the chronic phase or early accelerated phase of the disease

  5. Characteristics of the thick, compound refractive lens

    International Nuclear Information System (INIS)

    Pantell, Richard H.; Feinstein, Joseph; Beguiristain, H. Raul; Piestrup, Melvin A.; Gary, Charles K.; Cremer, Jay T.

    2003-01-01

    A compound refractive lens (CRL), consisting of a series of N closely spaced lens elements each of which contributes a small fraction of the total focusing, can be used to focus x rays or neutrons. The thickness of a CRL can be comparable to its focal length, whereupon a thick-lens analysis must be performed. In contrast with the conventional optical lens, where the ray inside the lens follows a straight line, the ray inside the CRL is continually changing direction because of the multiple refracting surfaces. Thus the matrix representation for the thick CRL is quite different from that for the thick optical lens. Principal planes can be defined such that the thick-lens matrix can be converted to that of a thin lens. For a thick lens the focal length is greater than for a thin lens with the same lens curvature, but this lengthening effect is less for the CRL than for the conventional optical lens

  6. Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography.

    Science.gov (United States)

    Chansangpetch, Sunee; Nguyen, Anwell; Mora, Marta; Badr, Mai; He, Mingguang; Porco, Travis C; Lin, Shan C

    2018-03-01

    To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771-0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95-3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04-3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12-1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (-0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably.

  7. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  8. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  9. DISSECTING THE GRAVITATIONAL LENS B1608+656. I. LENS POTENTIAL RECONSTRUCTION

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Blandford, R. D.; Fassnacht, C. D.; Koopmans, L. V. E.; McKean, J. P.; Treu, T.

    2009-01-01

    Strong gravitational lensing is a powerful technique for probing galaxy mass distributions and for measuring cosmological parameters. Lens systems with extended source-intensity distributions are particularly useful for this purpose since they provide additional constraints on the lens potential (

  10. The efficiency of aspheric intraocular lens according to biometric measurements.

    Science.gov (United States)

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  11. [Analysis of refractive status after cataract surgery in age-related cataract patients with shallow anterior chamber].

    Science.gov (United States)

    Yang, Fei; Hou, Xianru; Wu, Huijuan; Bao, Yongzhen

    2014-02-01

    To evaluate the characteristics of postoperative refractive status in age-related cataract patients with shallow anterior chamber and the correlation between pre-operative anterior chamber depth and postoperative refractive status. Prospective case-control study. Sixty-eight cases (90 eyes) with age-related cataract were recruited from October 2010 to January 2012 in People's Hospital Peking University including 28 cases (34 eyes) in control group and 40 cases (56 eyes) in shallow anterior chamber group according to anterior chamber depth (ACD) measured by Pentacam system. Axial length and keratometer were measured by IOL Master and intraocular lens power was calculated using SRK/T formula. Postoperative refraction, ACD and comprehensive eye examination were performed at 1 month and 3 months after cataract surgery. Using SPSS13.0 software to establish a database, the two groups were compared with independent samples t-test and correlation analysis were performed with binary logical regression. The postoperative refractive deviation at 1 month were (-0.39 ± 0.62) D in control group and (+0.73 ± 0.26) D in shallow anterior chamber group respectively which present statistical significance between the two groups (P = 0.00, t = 3.67); the postoperative refractive deviation in 3 month was (-0.37 ± 0.62) D in control group and (+0.79 ± 0.28) D in shallow anterior chamber group operatively which present statistical significance between the two groups (P = 0.00, t = 3.33). In shallow anterior chamber group, with the shallower of ACD, the greater of refractive deviation (P = 0.00, r1 month = -0.57, r3 months = -0.61). Hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened.

  12. Clinical observation of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract in the sight restoration project

    Directory of Open Access Journals (Sweden)

    Xiao-Jian Cheng

    2014-04-01

    Full Text Available AIM: To analyze the clinical effects of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract.METHODS:Totally 642 cases 676 eyes of cataract were treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Complication during and after operations and postoperative visual acuity was observed.RESULTS:Visual acuity of 670 eyes was ≥0.05 and off-blindness rate was 99.11%, and there was 627 eyes ≥0.3 and the off-disability rate was 92.75% after 1mo. Rupture of posterior capsule during surgery occurred in 24 eyes. Fifty-four eyes were corneal edema, and anterior chamber exudation were 26 eyes, and 23 eyes were hypertension after operation. CONCLUSION: There are a little complications during and after operation for cataract treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Patients have good recovery after operation. This operation does not need high-standard equipments and is suitable in the sight restoration project.

  13. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  14. Current issues in allogeneic islet transplantation.

    Science.gov (United States)

    Chang, Charles A; Lawrence, Michael C; Naziruddin, Bashoo

    2017-10-01

    Transplantation of allogenic pancreatic islets is a minimally invasive treatment option to control severe hypoglycemia and dependence on exogenous insulin among type 1 diabetes (T1D) patients. This overview summarizes the current issues and progress in islet transplantation outcomes and research. Several clinical trials from North America and other countries have documented the safety and efficacy of clinical islet transplantation for T1D patients with impaired hypoglycemia awareness. A recently completed phase 3 clinical trial allows centres in the United States to apply for a Food and Drug Administration Biologics License for the procedure. Introduction of anti-inflammatory drugs along with T-cell depleting induction therapy has significantly improved long-term function of transplanted islets. Research into islet biomarkers, immunosuppression, extrahepatic transplant sites and potential alternative beta cell sources is driving further progress. Allogeneic islet transplantation has vastly improved over the past two decades. Success in restoration of glycemic control and hypoglycemic awareness after islet transplantation has been further highlighted by clinical trials. However, lack of effective strategies to maintain long-term islet function and insufficient sources of donor tissue still impose limitations to the widespread use of islet transplantation. In the United States, wide adoption of this technology still awaits regulatory approval and, importantly, a financial mechanism to support the use of this technology.

  15. Lung function after allogeneic bone marrow transplantation for leukaemia or lymphoma

    DEFF Research Database (Denmark)

    Nysom, K; Holm, K; Hesse, B

    1996-01-01

    Longitudinal data were analysed on the lung function of 25 of 29 survivors of childhood leukaemia or lymphoma, who had been conditioned with cyclophosphamide and total body irradiation before allogeneic bone marrow transplantation, to test whether children are particularly vulnerable to pulmonary...... damage after transplantation. None developed chronic graft-versus-host disease. Transfer factor and lung volumes were reduced immediately after bone marrow transplantation, but increased during the following years. However, at the last follow up, 4-13 years (median 8) after transplantation, patients had...... to their age at bone marrow transplantation. In conclusion, patients had subclinical restrictive pulmonary disease at a median of eight years after total body irradiation and allogeneic bone marrow transplantation....

  16. Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy.

    Science.gov (United States)

    Narayanaswamy, Arun; Vijaya, Lingam; Shantha, B; Baskaran, Mani; Sathidevi, A V; Baluswamy, Sukumar

    2004-01-01

    Comparison of anterior chamber angle measurements using ultrasound biomicroscopy (UBM) and gonioscopy. Five hundred subjects were evaluated for grading of angle width by the Shaffer method. UBM was done in the same group to document angle width, angle opening distance (AOD 500), and anterior chamber depth. Biometric parameters were documented in all subjects. UBM and gonioscopic findings were compared. A study was conducted in 282 men and 218 women with a mean age of 57.32 +/- 12.48 years. Gonioscopic grading was used to segregate occludable (slit-like, grades 1 and 2) from nonoccludable (grades 3 and 4) angles. Subjective assessment by gonioscopy resulted in an overestimation of angle width within the occludable group when compared with values obtained by UBM. This did not affect the segregation of occludable versus nonoccludable angles by gonioscopy. Biometric parameters in eyes with occludable angles were significantly lower in comparison with eyes with nonoccludable angles, except for lens thickness. AOD 500 correlated well with angle width. We concluded that clinical segregation into occludable and nonoccludable angles by an experienced observer using gonioscopy is fairly accurate. However, UBM is required for objective quantification of angles, and AOD 500 can be a reliable and standard parameter to grade angle width.

  17. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  18. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  19. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  20. Mixed allogeneic reconstitution (A+B----A) to induce donor-specific transplantation tolerance. Permanent acceptance of a simultaneous donor skin graft

    International Nuclear Information System (INIS)

    Ildstad, S.T.; Wren, S.M.; Oh, E.; Hronakes, M.L.

    1991-01-01

    Mixed allogeneic reconstitution, in which a mixture of T-cell-depleted bone marrow of syngeneic host and allogeneic donor type is transplanted into a lethally irradiated recipient (A+B----A), results in mixed lymphopoietic chimerism with engraftment of a mixture of both host and donor bone marrow elements. Recipients are specifically tolerant to donor both in vitro and in vivo. Donor-specific skin grafts survive indefinitely when they are placed after full bone marrow repopulation at 28 days, while third-party grafts are rapidly rejected. To determine whether a delay of a month or more for full bone marrow repopulation is required before a donor-specific graft can be placed, we have now examined whether tolerance induction can be achieved if a graft is placed at the time of bone marrow transplantation. Permanent acceptance of donor-specific B10.BR skin grafts occurred when mixed allogeneic chimerism (B10+B10.BR----B10) was induced and a simultaneous allogeneic donor graft placed. In vitro, mixed reconstituted recipients were specifically tolerant to the B10.BR donor lymphoid cells but fully reactive to MHC-disparate third-party (BALB/c; H-2dd) when assessed by mixed lymphocyte reaction (MLR) and cell-mediated lympholysis (CML) assays. These data therefore indicate that a donor-specific graft placed at the time of mixed allogeneic reconstitution is permanently accepted without rejection. To determine whether an allogeneic skin graft alone without allogeneic bone marrow would be sufficient to induce tolerance, syngeneic reconstitution (B10----B10) was carried out, and a simultaneous B10.BR allogeneic skin graft placed. Although skin grafts were prolonged in all recipients, all grafts rejected when full lymphopoietic repopulation occurred at 28 days

  1. Allogeneic Transplantation of Periodontal Ligament-Derived Multipotent Mesenchymal Stromal Cell Sheets in Canine Critical-Size Supra-Alveolar Periodontal Defect Model.

    Science.gov (United States)

    Tsumanuma, Yuka; Iwata, Takanori; Kinoshita, Atsuhiro; Washio, Kaoru; Yoshida, Toshiyuki; Yamada, Azusa; Takagi, Ryo; Yamato, Masayuki; Okano, Teruo; Izumi, Yuichi

    2016-01-01

    Periodontitis is a chronic inflammatory disease that induces the destruction of tooth-supporting tissues, followed by tooth loss. Although several approaches have been applied to periodontal regeneration, complete periodontal regeneration has not been accomplished. Tissue engineering using a combination of cells and scaffolds is considered to be a viable alternative strategy. We have shown that autologous transplantation of periodontal ligament-derived multipotent mesenchymal stromal cell (PDL-MSC) sheets regenerates periodontal tissue in canine models. However, the indications for autologous cell transplantation in clinical situations are limited. Therefore, this study evaluated the safety and efficacy of allogeneic transplantation of PDL-MSC sheets using a canine horizontal periodontal defect model. Canine PDL-MSCs were labeled with enhanced green fluorescent protein (EGFP) and were cultured on temperature-responsive dishes. Three-layered cell sheets were transplanted around denuded root surfaces either autologously or allogeneically. A mixture of β-tricalcium phosphate and collagen gel was placed on the bone defects. Eight weeks after transplantation, dogs were euthanized and subjected to microcomputed tomography and histological analyses. RNA and DNA were extracted from the paraffin sections to verify the presence of EGFP at the transplantation site. Inflammatory markers from peripheral blood sera were quantified using an enzyme-linked immunosorbent assay. Periodontal regeneration was observed in both the autologous and the allogeneic transplantation groups. The allogeneic transplantation group showed particularly significant regeneration of newly formed cementum, which is critical for the periodontal regeneration. Serum levels of inflammatory markers from peripheral blood sera showed little difference between the autologous and allogeneic groups. EGFP amplicons were detectable in the paraffin sections of the allogeneic group. These results suggest that

  2. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  3. A standardized multidisciplinary approach reduces the use of allogeneic blood products in patients undergoing cardiac surgery.

    Science.gov (United States)

    Van der Linden, P; De Hert, S; Daper, A; Trenchant, A; Jacobs, D; De Boelpaepe, C; Kimbimbi, P; Defrance, P; Simoens, G

    2001-10-01

    Individual and institutional practices remain an independent predictor factor for allogeneic blood transfusion. Application of a standardized multidisciplinary transfusion strategy should reduce the use of allogeneic blood transfusion in major surgical patients. This prospective non randomized observational study evaluated the effects of a standardized multidisciplinary transfusion strategy on allogeneic blood products exposure in patients undergoing non-emergent cardiac surgery. The developed strategy involved a standardized blood conservation program and a multidisciplinary allogeneic blood transfusion policy based mainly on clinical judgement, not only on a specific hemoglobin concentration. Data obtained in a first group including patients operated from September 1997 to August 1998 (Group pre: n=321), when the transfusion strategy was progressively developed, were compared to those obtained in a second group, including patients operated from September 1998 to August 1999 (Group post: n=315) when the transfusion strategy was applied uniformly. Patient populations and surgical procedures were similar. Patients in Group post underwent acute normovolemic hemodilution more frequently, had a higher core temperature at arrival in the intensive care unit and presented lower postoperative blood losses at day one. Three hundred forty units of packed red blood cells were transfused in 33% of the patients in Group pre whereas 161 units were transfused in 18% of the patients in Group post (P <0.001). Pre- and postoperative hemoglobin concentrations, mortality and morbidity were not different among groups. Development of a standardized multidisciplinary transfusion strategy markedly reduced the exposure of cardiac surgery patients to allogeneic blood.

  4. Association of biometric factors with anterior chamber angle widening and intraocular pressure reduction after uneventful phacoemulsification for cataract.

    Science.gov (United States)

    Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Chen, Yi-Chun; He, Mingguang; Lin, Shan C

    2012-01-01

    To evaluate anterior chamber biometric factors associated with the degree of angle widening and intraocular pressure (IOP) reduction after phacoemulsification. University of California, San Francisco, California, USA. Case series. Anterior chamber parameters obtained by anterior segment coherence tomography were compared preoperatively and 3 months postoperatively. Measurements included the angle opening distance 500 μm anterior to the scleral spur (AOD500), trabecular-iris space area 500 μm from the scleral spur (TISA500), iris curvature (I-Curv), anterior chamber angle (ACA), trabecular-iris space area, anterior chamber volume, anterior chamber width, and lens vault (LV). The study enrolled 73 eyes. The mean patient age was 77.45 years ± 7.84 (SD); 65.75% of patients were women. From preoperatively to 3 months postoperatively, the mean AOD500 increased significantly (0.254 ± 0.105 to 0.433 ± 0.108 mm) and the mean IOP decreased significantly (14.97 ± 3.35 to 12.62 ± 3.37 mm Hg) (P<.001). The reduction in IOP was correlated with the increase in AOD500 (r = 0.240, P=.041) and preoperative LV (r = 0.235, P=.045). After adjusting for related factors, AOD500 widening was positively correlated with LV (β = 0.458, P=.044) and I-Curv (β = 0.235, P=.043) and negatively correlated with preoperative TISA500 (β = -0.269, P=.025) and ACA (β = -0.919, P=.027). Surgically induced AOD widening was significantly correlated with anterior chamber biometric factors. Preoperative LV appears to be a significant factor in angle widening and IOP reduction after phacoemulsification. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  6. 21 CFR 886.1375 - Bagolini lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bagolini lens. 886.1375 Section 886.1375 Food and... OPHTHALMIC DEVICES Diagnostic Devices § 886.1375 Bagolini lens. (a) Identification. A Bagolini lens is a device that consists of a plane lens containing almost imperceptible striations that do not obscure...

  7. Anterior perineal hernia after anterior exenteration

    Directory of Open Access Journals (Sweden)

    Ka Wing Wong

    2017-10-01

    Full Text Available Perineal hernia is a rare complication of anterior exenteration. We reported this complication after an anterior exenteration for bladder cancer with bleeding complication requiring packing and second-look laparotomy. Perineal approach is a simple and effective method for repair of perineal hernia.

  8. Allogeneic stem cell transplantation for patients harboring T315I BCR-ABL mutated leukemias

    DEFF Research Database (Denmark)

    Nicolini, Franck Emmanuel; Basak, Grzegorz W; Soverini, Simona

    2011-01-01

    T315I(+) Philadelphia chromosome-positive leukemias are inherently resistant to all licensed tyrosine kinase inhibitors, and therapeutic options remain limited. We report the outcome of allogeneic stem cell transplantation in 64 patients with documented BCR-ABL(T315I) mutations. Median follow......) as unfavorable factors. We conclude that allogeneic stem cell transplantation represents a valuable therapeutic tool for eligible patients with BCR-ABL(T315I) mutation, a tool that may or may not be replaced by third-generation tyrosine kinase inhibitors....

  9. Clinicopathologic findings following intra-articular injection of autologous and allogeneic placentally derived equine mesenchymal stem cells in horses.

    Science.gov (United States)

    Carrade, Danielle D; Owens, Sean D; Galuppo, Larry D; Vidal, Martin A; Ferraro, Gregory L; Librach, Fred; Buerchler, Sabine; Friedman, Michael S; Walker, Naomi J; Borjesson, Dori L

    2011-04-01

    The development of an allogeneic mesenchymal stem cell (MSC) product to treat equine disorders would be useful; however, there are limited in vivo safety data for horses. We hypothesized that the injection of self (autologous) and non-self (related allogeneic or allogeneic) MSC would not elicit significant alterations in physical examination, gait or synovial fluid parameters when injected into the joints of healthy horses. Sixteen healthy horses were used in this study. Group 1 consisted of foals (n = 6), group 2 consisted of their dams (n = 5) and group 3 consisted of half-siblings (n = 5) to group 1 foals. Prior to injection, MSC were phenotyped. Placentally derived MSC were injected into contralateral joints and MSC diluent was injected into a separate joint (control). An examination, including lameness evaluation and synovial fluid analysis, was performed at 0, 24, 48 and 72 h post-injection. MSC were major histocompatibility complex (MHC) I positive, MHC II negative and CD86 negative. Injection of allogeneic MSC did not elicit a systemic response. Local responses such as joint swelling or lameness were minimal and variable. Intra-articular MSC injection elicited marked inflammation within the synovial fluid (as measured by nucleated cell count, neutrophil number and total protein concentration). However, there were no significant differences between the degree and type of inflammation elicited by self and non-self-MSC. The healthy equine joint responds similarly to a single intra-articular injection of autologous and allogeneic MSC. This pre-clinical safety study is an important first step in the development of equine allogeneic stem cell therapies.

  10. Blood management in total hip replacement: an analysis of factors associated with allogenic blood transfusion.

    Science.gov (United States)

    Wong, Samuel; Tang, Howard; de Steiger, Richard

    2015-06-01

    The aim of this study was to audit the blood transfusion practice throughout the Epworth Healthcare Hospitals for patients undergoing primary total hip replacement (THR). We determined if blood-saving techniques were having an impact on the risk of allogenic blood transfusion and which patients were at risk of receiving allogenic blood transfusion. This study uses a retrospective audit of 787 patients who had undergone primary THR surgery at three Melbourne hospitals: Epworth Richmond, Epworth Eastern and Epworth Freemasons in 2010. Patient demographics, transfusion requirements and blood-conserving techniques were recorded. One hundred and eighty (23%) patients received allogenic blood transfusion and 18 (2.3%) patients received autologous blood transfusion. On multivariate analysis, preoperative anaemia (odds ratio (OR) 4.7, P blood transfusion. Use of spinal anaesthetic was found to be associated with lower risk of transfusion (OR 0.6, P = 0.0180) compared with general anaesthetic alone. Cell saver, acute normovolaemic haemodilution and re-infusion drain tube usage did not have a significant impact on reducing the risk of allogenic blood transfusion. Identification of patients at risk of blood transfusion, correction of preoperative anaemia and a restrictive transfusion policy are important factors to consider in effective perioperative blood management. © 2015 Royal Australasian College of Surgeons.

  11. Feasibility of combination allogeneic stem cell therapy for spinal cord injury: a case report

    Directory of Open Access Journals (Sweden)

    Ichim Thomas E

    2010-11-01

    Full Text Available Abstract Cellular therapy for spinal cord injury (SCI is overviewed focusing on bone marrow mononuclear cells, olfactory ensheathing cells, and mesenchymal stem cells. A case is made for the possibility of combining cell types, as well as for allogeneic use. We report the case of 29 year old male who suffered a crush fracture of the L1 vertebral body, lacking lower sensorimotor function, being a score A on the ASIA scale. Stem cell therapy comprised of intrathecal administration of allogeneic umbilical cord blood ex-vivo expanded CD34 and umbilical cord matrix MSC was performed 5 months, 8 months, and 14 months after injury. Cell administration was well tolerated with no adverse effects observed. Neuropathic pain subsided from intermittent 10/10 to once a week 3/10 VAS. Recovery of muscle, bowel and sexual function was noted, along with a decrease in ASIA score to "D". This case supports further investigation into allogeneic-based stem cell therapies for SCI.

  12. A Tribute to Len Barton

    Science.gov (United States)

    Tomlinson, Sally

    2010-01-01

    This article constitutes a short personal tribute to Len Barton in honour of his work and our collegial relationship going back over 30 years. It covers how Len saw his intellectual project of providing critical sociological and political perspectives on special education, disability and inclusion, and his own radical political perspectives. Len's…

  13. Photosensitized oxidation in the ocular lens: evidence for photosensitizers endogenous to the human lens

    International Nuclear Information System (INIS)

    Zigler, J.S. Jr.; Goosey, J.D.

    1981-01-01

    Numerous investigators have attempted to associate near UV light exposure with various changes which occur to lens crystallins during aging and cataractogenesis. Recently it was shown that in vitro singlet oxygen mediated oxidation of lens crystallins produces effects very similar to those documented for crystallins from old or cataractous lenses and it was suggested that near UV photodynamic effects may play a major role in vivo in aging in the human lens. It has now been shown that certain oxidation products of tryptophan which have been identified in human lens can act as near UV photosensitizers, producing singlet oxygen. The insoluble protein fraction from human cataracts was shown to have the capacity to act as a photosensitizer. An age-related increase in photosensitizing capacity was also demonstrated in the soluble crystallins from human lens. These findings are discussed with respect to development of pigmented nuclear cataracts. (author)

  14. Sexual function 1-year after allogeneic hematopoietic stem cell transplantation

    DEFF Research Database (Denmark)

    Noerskov, K. H.; Schjødt, I.; Syrjala, K. L.

    2016-01-01

    Treatment with allogeneic hematopoietic stem cell transplantation (HSCT) is associated with short and long-term toxicities that can result in alterations in sexual functioning. The aims of this prospective evaluation were to determine: (1) associations between HSCT and increased sexual dysfunction...

  15. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  16. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K; Sanada, C; Tsukino, M [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  17. Perioperative allogenic blood transfusion is a poor prognostic factor after hepatocellular carcinoma surgery: a multi-center analysis.

    Science.gov (United States)

    Wada, Hiroshi; Eguchi, Hidetoshi; Nagano, Hiroaki; Kubo, Shoji; Nakai, Takuya; Kaibori, Masaki; Hayashi, Michihiro; Takemura, Shigekazu; Tanaka, Shogo; Nakata, Yasuyuki; Matsui, Kosuke; Ishizaki, Morihiko; Hirokawa, Fumitoshi; Komeda, Koji; Uchiyama, Kazuhisa; Kon, Masanori; Doki, Yuichiro; Mori, Masaki

    2018-01-01

    The influence of allogenic blood transfusion on the postoperative outcomes of hepatocellular carcinoma (HCC) surgery remains controversial. This study aims to clarify the clinical impacts of perioperative allogenic blood transfusion on liver resection outcome in HCC patients. We analyzed data collected over 5 years for 642 patients who underwent hepatectomy for HCC at one of the five university hospitals. We investigated the impact of allogenic blood transfusion on postoperative outcome after surgery in all patients and in 74 matched pairs, using a propensity score. Of the 642 patients, 198 (30.8%) received perioperative allogenic blood transfusion (AT group) and 444 (69.2%) did not (non-AT group). Overall survival was lower in the AT group than in the non-AT group in univariate (P blood transfusion was found to be a poor prognostic factor for HCC patients. In this multi-center study, perioperative blood transfusion was an independent factor for poor prognosis after curative surgery for primary HCC in the patient group and in pairs matched by propensity scores.

  18. Allogeneic amniotic membrane-derived mesenchymal stromal cell transplantation in a porcine model of chronic myocardial ischemia

    Directory of Open Access Journals (Sweden)

    Kimura M

    2012-01-01

    Full Text Available Introduction. Amniotic membrane contains a multipotential stem cell population and is expected to possess the machinery to regulate immunological reactions. We investigated the safety and efficacy of allogeneic amniotic membrane-derived mesenchymal stromal cell (AMSC transplantation in a porcine model of chronic myocardial ischemia as a preclinical trial. Methods. Porcine AMSCs were isolated from amniotic membranes obtained by cesarean section just before delivery and were cultured to increase their numbers before transplantation. Chronic myocardial ischemia was induced by implantation of an ameroid constrictor around the left circumflex coronary artery. Four weeks after ischemia induction, nine swine were assigned to undergo either allogeneic AMSC transplantation or normal saline injection. Functional analysis was performed by echocardiography, and histological examinations were carried out by immunohistochemistry 4 weeks after AMSC transplantation. Results. Echocardiography demonstrated that left ventricular ejection fraction was significantly improved and left ventricular dilatation was well attenuated 4 weeks after AMSC transplantation. Histological assessment showed a significant reduction in percentage of fibrosis in the AMSC transplantation group. Injected allogeneic green fluorescent protein (GFP-expressing AMSCs were identified in the immunocompetent host heart without the use of any immunosuppressants 4 weeks after transplantation. Immunohistochemistry revealed that GFP colocalized with cardiac troponin T and cardiac troponin I. Conclusions. We have demonstrated that allogeneic AMSC transplantation produced histological and functional improvement in the impaired myocardium in a porcine model of chronic myocardial ischemia. The transplanted allogeneic AMSCs survived without the use of any immunosuppressants and gained cardiac phenotype through either their transdifferentiation or cell fusion.

  19. Luneburg lens in silicon photonics.

    Science.gov (United States)

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-03-14

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms.

  20. Crystalline lens and refractive development.

    Science.gov (United States)

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Transplantation of Allogeneic PW1pos/Pax7neg Interstitial Cells Enhance Endogenous Repair of Injured Porcine Skeletal Muscle

    Directory of Open Access Journals (Sweden)

    Fiona C. Lewis, BSc, PhD

    2017-12-01

    Full Text Available Skeletal muscle-derived PW1pos/Pax7neg interstitial cells (PICs express and secrete a multitude of proregenerative growth factors and cytokines. Utilizing a porcine preclinical skeletal muscle injury model, delivery of allogeneic porcine PICs (pPICs significantly improved and accelerated myofiber regeneration and neocapillarization, compared with saline vehicle control-treated muscles. Allogeneic pPICs did not contribute to new myofibers or capillaries and were eliminated by the host immune system. In conclusion, allogeneic pPIC transplantation stimulated the endogenous stem cell pool to bring about enhanced autologous skeletal muscle repair and regeneration. This allogeneic cell approach is considered a cost-effective, easy to apply, and readily available regenerative therapeutic strategy.

  2. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  3. Chondrocytic Potential of Allogenic Mesenchymal Stem Cells Transplanted without Immunosuppression to Regenerate Physeal Defect in Rabbits

    Directory of Open Access Journals (Sweden)

    P. Gál

    2007-01-01

    Full Text Available Mesenchymal stem cells (MSCs from bone marrow are multipotent cells capable of forming cartilage, bone, and other connective tissues. The objective of this study was to determine whether the use of allogenic mesenchymal stem cells could functionally heal a defect in the distal femoral physis in rabbits without the use of immunosuppressive therapy. A iatrogenic defect was created in the lateral femoral condyle of thirty-two New Zealand white rabbits, 7 weeks old, weighing 2.25 ± 0.24 kg. Each defect, 3.5 mm in width and 12 mm in length, in the right distal femoral physis was treated with allogenic mesenchymal stem cells in new composite hyaluronate/collagen type I/fibrin scaffold. The healing response was evaluated radiographically, by MRI (three weeks and four months after implantation and also histologically, by Pearl’s reaction and with immunofluorescence (four months after implantation. The results were compared with the data for the control defects (without stem cell implantation in left distal femoral physes. On average, right femurs with a damaged distal physis and transplanted MSCs grew more in length (0.55 ± 0.21 cm compared with left femurs with a physeal defect without stem cell transplantation (0.46 ± 0.23 cm. Valgus deformity of right femurs with a physeal defect and transplanted MSCs was mild (0.2 ± 0.1 °. On the contrary, left femurs with a physeal defect without transplanted MSCs showed a significant valgus deformity (2.7 ± 1.6 °. For defects treated with allogenic mesenchymal stem cell implants, no adverse immune response and implant rejection were detected in this model. Histologically, no lymphocytic infiltration occurred. At four months after transplantation, hyaline cartilage had formed throughout the defects treated with allogenic MSCs. Labelled mesenchymal stem cells/differentiated chondrocytes were detected in the physeal defects based on magnetic resonance imaging and immunofluorescence. The results of this study

  4. Changes in monkey crystalline lens spherical aberration during simulated accommodation in a lens stretcher.

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-02-10

    The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4-16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from -6.3 ± 0.7 μm for young lenses to -5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and -2.6 ± 0.5 μm, respectively. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  5. Symmetric lens with extended depth of focus

    OpenAIRE

    Cho, Sung Nae

    2008-01-01

    The lens surface profile is derived based on the instantaneous focal length versus the lens radius data. The lens design based on instantaneous focal length versus the lens radius data has many useful applications in software assisted image focusing technology.

  6. Autologous Dendritic Cells Pulsed with Allogeneic Tumor Cell Lysate in Mesothelioma: From Mouse to Human.

    Science.gov (United States)

    Aerts, Joachim G J V; de Goeje, Pauline L; Cornelissen, Robin; Kaijen-Lambers, Margaretha E H; Bezemer, Koen; van der Leest, Cor H; Mahaweni, Niken M; Kunert, André; Eskens, Ferry A L M; Waasdorp, Cynthia; Braakman, Eric; van der Holt, Bronno; Vulto, Arnold G; Hendriks, Rudi W; Hegmans, Joost P J J; Hoogsteden, Henk C

    2018-02-15

    Purpose: Mesothelioma has been regarded as a nonimmunogenic tumor, which is also shown by the low response rates to treatments targeting the PD-1/PD-L1 axis. Previously, we demonstrated that autologous tumor lysate-pulsed dendritic cell (DC) immunotherapy increased T-cell response toward malignant mesothelioma. However, the use of autologous tumor material hampers implementation in large clinical trials, which might be overcome by using allogeneic tumor cell lines as tumor antigen source. The purpose of this study was to investigate whether allogeneic lysate-pulsed DC immunotherapy is effective in mice and safe in humans. Experimental Design: First, in two murine mesothelioma models, mice were treated with autologous DCs pulsed with either autologous or allogeneic tumor lysate or injected with PBS (negative control). Survival and tumor-directed T-cell responses of these mice were monitored. Results were taken forward in a first-in-human clinical trial, in which 9 patients were treated with 10, 25, or 50 million DCs per vaccination. DC vaccination consisted of autologous monocyte-derived DCs pulsed with tumor lysate from five mesothelioma cell lines. Results: In mice, allogeneic lysate-pulsed DC immunotherapy induced tumor-specific T cells and led to an increased survival, to a similar extent as DC immunotherapy with autologous tumor lysate. In the first-in-human clinical trial, no dose-limiting toxicities were established and radiographic responses were observed. Median PFS was 8.8 months [95% confidence interval (CI), 4.1-20.3] and median OS not reached (median follow-up = 22.8 months). Conclusions: DC immunotherapy with allogeneic tumor lysate is effective in mice and safe and feasible in humans. Clin Cancer Res; 24(4); 766-76. ©2017 AACR . ©2017 American Association for Cancer Research.

  7. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  8. Comparison of immersion ultrasonography, ultrasound biomicroscopy and anterior segment optical coherence tomography in the evaluation of traumatic phacoceles

    Directory of Open Access Journals (Sweden)

    Harikrishna Vodapalli

    2012-01-01

    Full Text Available Blunt ocular trauma in the elderly can result in anterior dislocation of the crystalline lens into the subconjunctival space (phacocele. Although rare, this presentation can be missed, especially if the patient presents several days after the injury and if the lid is not everted on examination. While a careful clinical examination is adequate in the diagnosis, imaging techniques can be put to use for the accurate location of the associated sclera rupture. We report three cases of post-traumatic phacocele wherein ultrasound biomicroscopy (UBM was compared to the anterior segment optical coherence tomography (AS-OCT and B-scan ultrasonography (B-scan, in order to establish the best imaging tool for this condition. We concluded, based on image quality, that UBM could be the imaging modality of choice to aid in the diagnosis of phacocele.

  9. The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability.

    Science.gov (United States)

    Wolffsohn, James; Hall, Lee; Mroczkowska, Stephanie; Hunt, Olivia A; Bilkhu, Paramdeep; Drew, Tom; Sheppard, Amy

    2015-10-01

    To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Lens fit assessments were not different between brands (P>0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12h (P0.05). Movement-on-blink was unaffected by wear-time (F=0.403, P=0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r=-0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P>0.01). Among the lenses tested, objective lens fit changed between 8h and 12h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  10. Effect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with Cataract

    Directory of Open Access Journals (Sweden)

    Tansu Gönen

    2011-08-01

    Full Text Available Purpose: To evaluate the effect of preoperative anterior chamber depth (ACD on intraocular pressure (IOP after uneventful phacoemulsification and intraocular lens (IOL implantation in nonglaucomatous eyes. Material and Method: The medical records of fifty-five patients (30 male and 25 female were reviewed retrospectively. The patients who had undergone uneventful phacoemulsification and IOL implantation were divided into two groups according to the values of preoperative ACD: 30 eyes in group 1 (ACD≤3.27 mm and 25 eyes in group 2 (ACD>3.27 mm. IOP was measured using non-contact tonometer preoperatively and postoperatively (1 day, 1 week, 1 month, and 3 months. Results: Three months after phacoemulsification and IOL implantation, the mean IOP decreased 23.6% in group 1 and 13.7% in group 2. There was a statistically significant difference between the groups (p= 0.025. Discussion: The mean IOP decreases in eyes with shallow anterior chamber more than in normal eyes after uncomplicated phacoemulsification and IOL implantation. (Turk J Ophthalmol 2011; 41: 207-12

  11. Microplasma Induced Cell Morphological Changes and Apoptosis of Ex Vivo Cultured Human Anterior Lens Epithelial Cells - Relevance to Capsular Opacification.

    Directory of Open Access Journals (Sweden)

    Nina Recek

    Full Text Available Inducing selective or targeted cell apoptosis without affecting large number of neighbouring cells remains a challenge. A plausible method for treatment of posterior capsular opacification (PCO due to remaining lens epithelial cells (LECs by reactive chemistry induced by localized single electrode microplasma discharge at top of a needle-like glass electrode with spot size ~3 μm is hereby presented. The focused and highly-localized atmospheric pressure microplasma jet with electrode discharge could induce a dose-dependent apoptosis in selected and targeted individual LECs, which could be confirmed by real-time monitoring of the morphological and structural changes at cellular level. Direct cell treatment with microplasma inside the medium appeared more effective in inducing apoptosis (caspase 8 positivity and DNA fragmentation at a highly targeted cell level compared to treatment on top of the medium (indirect treatment. Our results show that single cell specific micropipette plasma can be used to selectively induce demise in LECs which remain in the capsular bag after cataract surgery and thus prevent their migration (CXCR4 positivity to the posterior lens capsule and PCO formation.

  12. Long-term outcomes among older patients following nonmyeloablative conditioning and allogeneic hematopoietic cell transplantation for advanced hematologic malignancies

    DEFF Research Database (Denmark)

    Sorror, Mohamed L; Sandmaier, Brenda M; Storer, Barry E

    2011-01-01

    A minimally toxic nonmyeloablative regimen was developed for allogeneic hematopoietic cell transplantation (HCT) to treat patients with advanced hematologic malignancies who are older or have comorbid conditions.......A minimally toxic nonmyeloablative regimen was developed for allogeneic hematopoietic cell transplantation (HCT) to treat patients with advanced hematologic malignancies who are older or have comorbid conditions....

  13. Upregulations of Clcn3 and P-Gp Provoked by Lens Osmotic Expansion in Rat Galactosemic Cataract

    Directory of Open Access Journals (Sweden)

    Lixia Ji

    2017-01-01

    Full Text Available Objective. Lens osmotic expansion, provoked by overactivated aldose reductase (AR, is the most essential event of sugar cataract. Chloride channel 3 (Clcn3 is a volume-sensitive channel, mainly participating in the regulation of cell fundamental volume, and P-glycoprotein (P-gp acts as its modulator. We aim to study whether P-gp and Clcn3 are involved in lens osmotic expansion of galactosemic cataract. Methods and Results. In vitro, lens epithelial cells (LECs were primarily cultured in gradient galactose medium (10–60 mM, more and more vacuoles appeared in LEC cytoplasm, and mRNA and protein levels of AR, P-gp, and Clcn3 were synchronously upregulated along with the increase of galactose concentration. In vivo, we focused on the early stage of rat galactosemic cataract, amount of vacuoles arose from equatorial area and scattered to the whole anterior capsule of lenses from the 3rd day to the 9th day, and mRNA and protein levels of P-gp and Clcn3 reached the peak around the 9th or 12th day. Conclusion. Galactosemia caused the osmotic stress in lenses; it also markedly leads to the upregulations of AR, P-gp, and Clcn3 in LECs, together resulting in obvious osmotic expansion in vitro and in vivo.

  14. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  15. 21 CFR 886.5844 - Prescription spectacle lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription spectacle lens. 886.5844 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5844 Prescription spectacle lens. (a) Identification. A prescription spectacle lens is a glass or plastic device that is a lens intended to be worn by...

  16. Low immunogenicity of allogeneic human umbilical cord blood-derived mesenchymal stem cells in vitro and in vivo

    International Nuclear Information System (INIS)

    Lee, Miyoung; Jeong, Sang Young; Ha, Jueun; Kim, Miyeon; Jin, Hye Jin; Kwon, Soon-Jae; Chang, Jong Wook; Choi, Soo Jin; Oh, Wonil; Yang, Yoon Sun; Kim, Jae-Sung; Jeon, Hong Bae

    2014-01-01

    Highlights: • hUCB-MSCs maintained low immunogenicity even after immune challenge in vitro. • Humanized NSG mice were established using human UCB CD34+ cells. • Repeated intravenous hUCB-MSC injection into mice did not lead to immune responses and adverse events. • Allogeneic hUCB-MSCs maintained low immunogenicity in vitro and in vivo. - Abstract: Evaluation of the immunogenicity of human mesenchymal stem cells (MSCs) in an allogeneic setting during therapy has been hampered by lack of suitable models due to technical and ethical limitations. Here, we show that allogeneic human umbilical cord blood derived-MSCs (hUCB-MSCs) maintained low immunogenicity even after immune challenge in vitro. To confirm these properties in vivo, a humanized mouse model was established by injecting isolated hUCB-derived CD34+ cells intravenously into immunocompromised NOD/SCID IL2γnull (NSG) mice. After repeated intravenous injection of human peripheral blood mononuclear cells (hPBMCs) or MRC5 cells into these mice, immunological alterations including T cell proliferation and increased IFN-γ, TNF-α, and human IgG levels, were observed. In contrast, hUCB-MSC injection did not elicit these responses. While lymphocyte infiltration in the lung and small intestine and reduced survival rates were observed after hPBMC or MRC5 transplantation, no adverse events were observed following hUCB-MSC introduction. In conclusion, our data suggest that allogeneic hUCB-MSCs have low immunogenicity in vitro and in vivo, and are therefore “immunologically safe” for use in allogeneic clinical applications

  17. Low immunogenicity of allogeneic human umbilical cord blood-derived mesenchymal stem cells in vitro and in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Miyoung; Jeong, Sang Young; Ha, Jueun; Kim, Miyeon; Jin, Hye Jin; Kwon, Soon-Jae [Biomedical Research Institute, MEDIPOST Co., Ltd, Seoul 137-874 (Korea, Republic of); Chang, Jong Wook [Research Institute for Future Medicine Stem Cell and Regenerative Medicine Center, Samsung Medical Center, Seoul 137-710 (Korea, Republic of); Choi, Soo Jin; Oh, Wonil; Yang, Yoon Sun [Biomedical Research Institute, MEDIPOST Co., Ltd, Seoul 137-874 (Korea, Republic of); Kim, Jae-Sung [Division of Radiation Cancer Research, Korea Institute of Radiological and Medical Sciences, Seoul 139-709 (Korea, Republic of); Jeon, Hong Bae, E-mail: jhb@medi-post.co.kr [Biomedical Research Institute, MEDIPOST Co., Ltd, Seoul 137-874 (Korea, Republic of)

    2014-04-18

    Highlights: • hUCB-MSCs maintained low immunogenicity even after immune challenge in vitro. • Humanized NSG mice were established using human UCB CD34+ cells. • Repeated intravenous hUCB-MSC injection into mice did not lead to immune responses and adverse events. • Allogeneic hUCB-MSCs maintained low immunogenicity in vitro and in vivo. - Abstract: Evaluation of the immunogenicity of human mesenchymal stem cells (MSCs) in an allogeneic setting during therapy has been hampered by lack of suitable models due to technical and ethical limitations. Here, we show that allogeneic human umbilical cord blood derived-MSCs (hUCB-MSCs) maintained low immunogenicity even after immune challenge in vitro. To confirm these properties in vivo, a humanized mouse model was established by injecting isolated hUCB-derived CD34+ cells intravenously into immunocompromised NOD/SCID IL2γnull (NSG) mice. After repeated intravenous injection of human peripheral blood mononuclear cells (hPBMCs) or MRC5 cells into these mice, immunological alterations including T cell proliferation and increased IFN-γ, TNF-α, and human IgG levels, were observed. In contrast, hUCB-MSC injection did not elicit these responses. While lymphocyte infiltration in the lung and small intestine and reduced survival rates were observed after hPBMC or MRC5 transplantation, no adverse events were observed following hUCB-MSC introduction. In conclusion, our data suggest that allogeneic hUCB-MSCs have low immunogenicity in vitro and in vivo, and are therefore “immunologically safe” for use in allogeneic clinical applications.

  18. Long-term survival of transplanted allogeneic cells engineered to express a T cell chemorepellent.

    Science.gov (United States)

    Papeta, Natalia; Chen, Tao; Vianello, Fabrizio; Gererty, Lyle; Malik, Ashish; Mok, Ying-Ting; Tharp, William G; Bagley, Jessamyn; Zhao, Guiling; Stevceva, Liljana; Yoon, Victor; Sykes, Megan; Sachs, David; Iacomini, John; Poznansky, Mark C

    2007-01-27

    Alloantigen specific T cells have been shown to be required for allograft rejection. The chemokine, stromal cell derived factor-1 (SDF-1) at high concentration, has been shown to act as a T-cell chemorepellent and abrogate T-cell infiltration into a site of antigen challenge in vivo via a mechanism termed fugetaxis or chemorepulsion. We postulated that this mechanism could be exploited therapeutically and that allogeneic cells engineered to express a chemorepellent protein would not be rejected. Allogeneic murine insulinoma beta-TC3 cells and primary islets from BALB/C mice were engineered to constitutively secrete differential levels of SDF-1 and transplanted into allogeneic diabetic C57BL/6 mice. Rejection was defined as the permanent return of hyperglycemia and was correlated with the level of T-cell infiltration. The migratory response of T-cells to SDF-1 was also analyzed by transwell migration assay and time-lapse videomicroscopy. The cytotoxicity of cytotoxic T cell (CTLs) against beta-TC3 cells expressing high levels of SDF-1 was measured in standard and modified chromium-release assays in order to determine the effect of CTL migration on killing efficacy. Control animals rejected allogeneic cells and remained diabetic. In contrast, high level SDF-1 production by transplanted cells resulted in increased survival of the allograft and a significant reduction in blood glucose levels and T-cell infiltration into the transplanted tissue. This is the first demonstration of a novel approach that exploits T-cell chemorepulsion to induce site specific immune isolation and thereby overcomes allograft rejection without the use of systemic immunosuppression.

  19. Activated Allogeneic NK Cells Preferentially Kill Poor Prognosis B-Cell Chronic Lymphocytic Leukemia Cells.

    Science.gov (United States)

    Sánchez-Martínez, Diego; Lanuza, Pilar M; Gómez, Natalia; Muntasell, Aura; Cisneros, Elisa; Moraru, Manuela; Azaceta, Gemma; Anel, Alberto; Martínez-Lostao, Luis; Villalba, Martin; Palomera, Luis; Vilches, Carlos; García Marco, José A; Pardo, Julián

    2016-01-01

    Mutational status of TP53 together with expression of wild-type (wt) IGHV represents the most widely accepted biomarkers, establishing a very poor prognosis in B-cell chronic lymphocytic leukemia (B-CLL) patients. Adoptive cell therapy using allogeneic HLA-mismatched Natural killer (NK) cells has emerged as an effective and safe alternative in the treatment of acute myeloid and lymphoid leukemias that do not respond to traditional therapies. We have described that allogeneic activated NK cells eliminate hematological cancer cell lines with multidrug resistance acquired by mutations in the apoptotic machinery. This effect depends on the activation protocol, being B-lymphoblastoid cell lines (LCLs) the most effective stimulus to activate NK cells. Here, we have further analyzed the molecular determinants involved in allogeneic NK cell recognition and elimination of B-CLL cells, including the expression of ligands of the main NK cell-activating receptors (NKG2D and NCRs) and HLA mismatch. We present preliminary data suggesting that B-CLL susceptibility significantly correlates with HLA mismatch between NK cell donor and B-CLL patient. Moreover, we show that the sensitivity of B-CLL cells to NK cells depends on the prognosis based on TP53 and IGHV mutational status. Cells from patients with worse prognosis (mutated TP53 and wt IGHV ) are the most susceptible to activated NK cells. Hence, B-CLL prognosis may predict the efficacy of allogenic activated NK cells, and, thus, NK cell transfer represents a good alternative to treat poor prognosis B-CLL patients who present a very short life expectancy due to lack of effective treatments.

  20. Plasma Lens for Muon and Neutrino Beams

    International Nuclear Information System (INIS)

    Kahn, S.A.; Korenev, S.; Bishai, M.; Diwan, M.; Gallardo, J.C.; Hershcovitch, A.; Johnson, B.M.

    2008-01-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-energy lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma for optimum focusing. The plasma lens is immersed in an additional solenoid magnetic field to facilitate the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. Plasma lenses have the additional advantage of negligible pion absorption and scattering by the lens material and reduced neutrino contamination during anti-neutrino running. Results of particle simulations using plasma lens will be presented

  1. Application of lens capsules tension reducing capsulorhexis and conventional capsulorhexis in the white cataract phacoemulsification

    Directory of Open Access Journals (Sweden)

    Rong-Feng Liu

    2017-09-01

    Full Text Available Objective: To explore the clinical effect of lens capsules tension reducing capsulorhexis and conventional capsulorhexis in the white cataract phacoemulsification. Methods: A total of 68 patients (76 eyes with white cataract who were admitted in our hospital from June, 2011 to June, 2016 were included in the study and divided into the experiment group (n=34, 36 eyes and the control group (n=34, 40 eyes according to the difference of intraoperative capsulorhexis. All the patients were performed with cataract phacoemulsification in combined with intraocular lens implantation. The patients in the experiment group were performed with lens capsules tension reducing capsulorhexis, while the patients in the control group were performed with conventional capsulorhexis. The integrity of the anterior capsule capsulorhexis, the degree of corneal endothelium edema, the intraocular lens deviation, uncorrected visual acuity, and corneal endothelial cell count in the two groups were compared. Results: A total of 34 eyes (94.44% in the experiment group and 35 eyes (87.50% in the control group successfully completed continuous annular capsulorhexis, and there was no significant difference between the 2 groups. The number of patients whose uncorrected visual acuity was greater than 0.5 increased 1 d-6 months after operation, and that in the experiment group was significantly higher than that in the control group. The difference of intraocular lens deviation rates between the 2 groups at different times after operation was not significant. The corneal endothelial cell count 1 d-6 months after operation in the 2 groups was significantly decreased when compared with before operation, but the difference between the 2 groups was not significant. The number of eyes without edema in the experiment group 1d after operation was significantly higher than that in the control group, and the number of eyes with grade Ⅱ edema was significantly less than that in the control

  2. Differential diagnosis of skin lesions after allogeneic haematopoietic stem cell transplantation

    NARCIS (Netherlands)

    Canninga-van Dijk, MR; Sanders, CJ; Verdonck, LF; Fijnheer, R; van den Tweel, JG

    Allogeneic haematopoietic stem cell transplantation (i.e. bone marrow or peripheral blood stem cell transplantation) is a common procedure in the treatment of various haematological disorders such as aplastic anaemia, (pre)leukaemias, some malignant lymphomas, multiple myeloma and immunodeficiency

  3. Soluble urokinase plasminogen activator receptor during allogeneic stem cell transplantation

    DEFF Research Database (Denmark)

    Haastrup, E; Andersen, J; Ostrowski, S R

    2011-01-01

    the course of allogeneic stem cell transplantation (SCT). Twenty SCT patients were included in the study. suPAR was measured by ELISA in daily taken plasma samples during the pretransplant conditioning with chemotherapy and weekly for 1 month after infusion of the graft. suPAR levels before the start...

  4. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  5. Clinical study of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes

    Directory of Open Access Journals (Sweden)

    Ru-Fa Meng

    2015-07-01

    Full Text Available AIM: To investigate the operation methods and clinical effects of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes.METHODS: During January 2012 to January 2014, foldable intraocular lens was implanted on 47 cases following lens-vitrectomy in residual capsular with traumatic eyes 3~6mo. Follow-up period was 6~12mo, averaged(8.21±2.63mo. RESULTS:All of 47 eyes had successful operation at one time, and position deviation was not appeared. The naked vision of the last postoperative follow-up was(0.44±0.19. Compared with best corrected visual acuity(0.41±0.23, and There was no significant difference between visual acuity of preoperative and last follow-up period(t=0.879, P=0.342. No severe complication was found. CONCLUSION: Secondary implantation of foldable intraocular lens is a safe and reliable method for correcting ametropia after lens-vitrectomy in residual capsular with traumatic eyes.

  6. Diquafosol Ophthalmic Solution Increases Pre- and Postlens Tear Film During Contact Lens Wear in Rabbit Eyes.

    Science.gov (United States)

    Nagahara, Yukiko; Koh, Shizuka; Oshita, Yoshihiro; Nagano, Takashi; Mano, Hidetoshi; Nishida, Kohji; Watanabe, Hitoshi

    2017-11-01

    To investigate the behavior of prelens tear film (PLTF) and postlens tear film (PoLTF) after the instillation of diquafosol using an experimental rabbit model of eyes with contact lens. Cross-sectional, anterior segment optical coherence tomographic images of the inferior midperipheral cornea were obtained at baseline and at 5, 15, 30, 60, 90, and 120 min after the instillation of 3% diquafosol ophthalmic solution in 10 Japanese white rabbits wearing contact lenses. From the obtained images, the areas of the PLTF and PoLTF were calculated. Both artificial tear solution and 0.1% sodium hyaluronate ophthalmic solution were used for comparison. Significant fluid accumulation in both the PLTF and PoLTF was observed after diquafosol instillation, whereas no fluid accumulation was visible after the instillation of artificial tear or sodium hyaluronate. The increase in PLTF area after diquafosol instillation was significantly higher (Pophthalmic solution increases PLTF and PoLTF in rabbit eyes with contact lenses. Diquafosol has potential as a treatment option for contact lens-related dry eye.

  7. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  8. Allogeneic hematopoietic stem-cell transplantation for acute myeloid leukemia in remission

    DEFF Research Database (Denmark)

    Nagler, Arnon; Rocha, Vanderson; Labopin, Myriam

    2013-01-01

    Cyclophosphamide (Cy) combined with total-body irradiation (TBI) or with busulfan (Bu) are currently the most common myeloablative regimens used in allogeneic stem-cell transplantation (alloSCT) in adults with acute myelogenous leukemia (AML). Intravenous (IV) Bu has more predictable...

  9. A novel cancer vaccine strategy based on HLA-A*0201 matched allogeneic plasmacytoid dendritic cells.

    Directory of Open Access Journals (Sweden)

    Caroline Aspord

    Full Text Available BACKGROUND: The development of effective cancer vaccines still remains a challenge. Despite the crucial role of plasmacytoid dendritic cells (pDCs in anti-tumor responses, their therapeutic potential has not yet been worked out. We explored the relevance of HLA-A*0201 matched allogeneic pDCs as vectors for immunotherapy. METHODS AND FINDINGS: Stimulation of PBMC from HLA-A*0201(+ donors by HLA-A*0201 matched allogeneic pDCs pulsed with tumor-derived peptides triggered high levels of antigen-specific and functional cytotoxic T cell responses (up to 98% tetramer(+ CD8 T cells. The pDC vaccine demonstrated strong anti-tumor therapeutic in vivo efficacy as shown by the inhibition of tumor growth in a humanized mouse model. It also elicited highly functional tumor-specific T cells ex-vivo from PBMC and TIL of stage I-IV melanoma patients. Responses against MelA, GP100, tyrosinase and MAGE-3 antigens reached tetramer levels up to 62%, 24%, 85% and 4.3% respectively. pDC vaccine-primed T cells specifically killed patients' own autologous melanoma tumor cells. This semi-allogeneic pDC vaccine was more effective than conventional myeloid DC-based vaccines. Furthermore, the pDC vaccine design endows it with a strong potential for clinical application in cancer treatment. CONCLUSIONS: These findings highlight HLA-A*0201 matched allogeneic pDCs as potent inducers of tumor immunity and provide a promising immunotherapeutic strategy to fight cancer.

  10. Modulation of allogeneic stimulation in man. I. Characterization of an in vitro induced suppressor macrophage population

    International Nuclear Information System (INIS)

    Stux, S.V.; Dubey, D.P.; Yunis, E.J.

    1981-01-01

    Cultured human peripheral blood mononuclear cells suppressed the allogeneic response of fresh autologous lymphocytes. This suppressor activity developed gradually over a period of one week. The cells primarily responsible for this effect were enriched by Ficoll density gradient centrifugation. It was found that the suppressor cell is a large, low density nylon wool adherent, radioresistant, phagocytic, and nonspecific esterase positive mononuclear cell. Moreover, these cells did not form E rosettes and were Fc positive. Electron microscopy confirmed that suppressor cells were macrophage like. Suppressor activity was not due to cytotoxicity, crowding, or steric hinderance by the cultured cells. The suppressor macrophage population did not appear to inhibit the allogeneic response via prostaglandin or arginase release, or interfere with the tritiated thymidine uptake by release of endogenous thymidine. The above system is viewed as an in vitro model of immune regulation by suppressor macrophages, in the context of allogeneic response

  11. Intraocular Foreign Body Detected by Gonioscopy in the Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Özdemir Özdemir

    2013-08-01

    Full Text Available 45-year-old male patient was referred to our hospital with suspicion of foreign body in the right eye. It was learned that a metal burr entered his right eye 2 days ago. Best-corrected visual acuity in the right eye was 9/10. Biomicroscopic examination showed a 2-mm fullthickness corneal incision in the lower paracentral cornea. Defect on the iris corresponding to the incision line drew our attention. Seidel test was negative. After dilatation, the anterior lens capsule and fundus examinations were performed and were normal. The presence of intraocular foreign body (IOFB was suspected and it was detected in the lower quadrant of the iridocorneal angle by gonioscopy. Emergency surgery was performed and IOFB was extracted. (Turk J Ophthalmol 2013; 43: 278-81

  12. Anterior cervical fusion: the role of anterior plating.

    Science.gov (United States)

    Daffner, Scott D; Wang, Jeffrey C

    2009-01-01

    Treatment of cervical pathology requires a clear understanding of the biomechanical benefits and limitations of cervical plates, their indications, and their associated complications. The use of anterior cervical plates has evolved significantly since their early application in cervical trauma. They have become widely used for anterior cervical decompression and fusion for cervical spondylosis. Plate design has undergone significant refinement and innovation, from the initial unlocked plates requiring bicortical purchase to the latest rotationally and translationally semiconstrained dynamic plates. Excellent clinical results have been reported for single-level anterior cervical decompression and fusion with or without plate fixation; however, the addition of an anterior cervical plate clearly leads to earlier fusion and better clinical results in longer fusions. Longer fusions should ideally consist of corpectomies and strut grafting because the decreased number of fusion surfaces tends to lead to higher fusion rates. Although anterior plate fixation leads to higher fusion rates in fusions of three or more levels, the associated pseudarthrosis rate is still high. The use of dynamic plates, through increased load sharing across the graft and decreased stress shielding, may improve fusion rates, particularly in long fusions. Nevertheless, adjuvant posterior fixation is recommended for fusions of more than three vertebral levels. Anterior plate fixation may be of particular benefit in the management of traumatic injuries, in revision settings, and in the treatment of smokers. Complications unique to plate fixation include hardware breakage and migration as well as ossification of the adjacent disk levels.

  13. Developing the Regulatory Utility of the Exposome: Mapping Exposures for Risk Assessment through Lifestage Exposome Snapshots (LEnS).

    Science.gov (United States)

    Shaffer, Rachel M; Smith, Marissa N; Faustman, Elaine M

    2017-08-07

    Exposome-related efforts aim to document the totality of human exposures across the lifecourse. This field has advanced rapidly in recent years but lacks practical application to risk assessment, particularly for children's health. Our objective was to apply the exposome to children's health risk assessment by introducing the concept of Lifestage Exposome Snapshots (LEnS). Case studies are presented to illustrate the value of the framework. The LEnS framework encourages organization of exposome studies based on windows of susceptibility for particular target organ systems. Such analyses will provide information regarding cumulative impacts during specific critical periods of the life course. A logical extension of this framework is that regulatory standards should analyze exposure information by target organ, rather than for a single chemical only or multiple chemicals grouped solely by mechanism of action. The LEnS concept is a practical refinement to the exposome that accounts for total exposures during particular windows of susceptibility in target organ systems. Application of the LEnS framework in risk assessment and regulation will improve protection of children's health by enhancing protection of sensitive developing organ systems that are critical for lifelong health and well-being. https://doi.org/10.1289/EHP1250.

  14. Impact of lens case hygiene guidelines on contact lens case contamination.

    Science.gov (United States)

    Wu, Yvonne T; Teng, Yuu Juan; Nicholas, Mary; Harmis, Najat; Zhu, Hua; Willcox, Mark D P; Stapleton, Fiona

    2011-10-01

    Lens case contamination is a risk factor for microbial keratitis. The effectiveness of manufacturers' lens case cleaning guidelines in limiting microbial contamination has not been evaluated in vivo. This study compared the effectiveness of manufacturers' guidelines and an alternative cleaning regimen. A randomized cross-over clinical trial with two phases (n = 40) was performed. Participants used the lens types of their choice in conjunction with the provided multipurpose solution (containing polyhexamethylene biguanide) for daily wear. In the manufacturers' guideline phase, cases were rinsed with multipurpose solution and air dried. In the alternative regimen phase, cases were rubbed, rinsed with solution, tissue wiped, and air-dried face down. The duration of each phase was 1 month. Lens cases were collected at the end of each phase for microbiological investigation. The levels of microbial contamination were compared, and compliance to both regimens was assessed. The case contamination rate was 82% (32/39) in the manufacturers' guideline group, compared with 72% (28/39) in the alternative regimen group. There were significantly fewer (p = 0.004) colony forming units (CFU) of bacteria from cases used by following the alternative regimen (CFU range of 0 to 10, and median of 12 CFU per well) compared with that of the manufacturer's guidelines (CFU range of 0 to 10, and median of 28 CFU per well). The compliance level between both guidelines was not significantly different (p > 0.05). The alternative guidelines are more effective in eliminating microbial contamination from lens cases than that of the current manufacturer's guideline. Simply incorporating rubbing and tissue-wiping steps in daily case hygiene reduces viable organism contamination.

  15. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  16. 21 CFR 886.1400 - Maddox lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maddox lens. 886.1400 Section 886.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1400 Maddox lens. (a) Identification. A Maddox lens is a device...

  17. Frequent induction of chromosomal aberrations in in vivo skin fibroblasts after allogeneic stem cell transplantation: hints to chromosomal instability after irradiation

    International Nuclear Information System (INIS)

    Massenkeil, G.; Zschieschang, P.; Thiel, G.; Hemmati, P. G.; Budach, V.; Dörken, B.; Pross, J.; Arnold, R.

    2015-01-01

    Total body irradiation (TBI) has been part of standard conditioning regimens before allogeneic stem cell transplantation for many years. Its effect on normal tissue in these patients has not been studied extensively. We studied the in vivo cytogenetic effects of TBI and high-dose chemotherapy on skin fibroblasts from 35 allogeneic stem cell transplantation (SCT) patients. Biopsies were obtained prospectively (n = 18 patients) before, 3 and 12 months after allogeneic SCT and retrospectively (n = 17 patients) 23–65 months after SCT for G-banded chromosome analysis. Chromosomal aberrations were detected in 2/18 patients (11 %) before allogeneic SCT, in 12/13 patients (92 %) after 3 months, in all patients after 12 months and in all patients in the retrospective group after allogeneic SCT. The percentage of aberrant cells was significantly higher at all times after allogeneic SCT compared to baseline analysis. Reciprocal translocations were the most common aberrations, but all other types of stable, structural chromosomal aberrations were also observed. Clonal aberrations were observed, but only in three cases they were detected in independently cultured flasks. A tendency to non-random clustering throughout the genome was observed. The percentage of aberrant cells was not different between patients with and without secondary malignancies in this study group. High-dose chemotherapy and TBI leads to severe chromosomal damage in skin fibroblasts of patients after SCT. Our long-term data suggest that this damage increases with time, possibly due to in vivo radiation-induced chromosomal instability

  18. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    Science.gov (United States)

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  19. Expression of the type VI intermediate filament proteins CP49 and filensin in the mouse lens epithelium.

    Science.gov (United States)

    FitzGerald, Paul; Sun, Ning; Shibata, Brad; Hess, John F

    2016-01-01

    The differentiated lens fiber cell assembles a filamentous cytoskeletal structure referred to as the beaded filament (BF). The BF requires CP49 (bfsp2) and filensin (bfsp1) for assembly, both of which are highly divergent members of the large intermediate filament (IF) family of proteins. Thus far, these two proteins have been reported only in the differentiated lens fiber cell. For this reason, both proteins have been considered robust markers of fiber cell differentiation. We report here that both proteins are also expressed in the mouse lens epithelium, but only after 5 weeks of age. Localization of CP49 was achieved with immunocytochemical probing of wild-type, CP49 knockout, filensin knockout, and vimentin knockout mice, in sections and in the explanted lens epithelium, at the light microscope and electron microscope levels. The relationship between CP49 and other cytoskeletal elements was probed using fluorescent phalloidin, as well as with antibodies to vimentin, GFAP, and α-tubulin. The relationship between CP49 and the aggresome was probed with antibodies to γ-tubulin, ubiquitin, and HDAC6. CP49 and filensin were expressed in the mouse lens epithelium, but only after 5 weeks of age. At the light microscope level, these two proteins colocalize to a large tubular structure, approximately 7 × 1 μm, which was typically present at one to two copies per cell. This structure is found in the anterior and anterolateral lens epithelium, including the zone where mitosis occurs. The structure becomes smaller and largely undetectable closer to the equator where the cell exits the cell cycle and commits to fiber cell differentiation. This structure bears some resemblance to the aggresome and is reactive with antibodies to HDAC6, a marker for the aggresome. However, the structure does not colocalize with antibodies to γ-tubulin or ubiquitin, also markers for the aggresome. The structure also colocalizes with actin but appears to largely exclude vimentin and

  20. Survey of expert opinions and related recommendations regarding bridging therapy using hypomethylating agents followed by allogeneic transplantation for high-risk MDS.

    Science.gov (United States)

    Sohn, Sang Kyun; Moon, Joon Ho

    2015-08-01

    According to current guidelines on therapeutic strategies for myelodysplastic syndrome (MDS), cytoreductive therapies before allogeneic stem cell transplantation (SCT) are not widely recommended for patients with high-risk MDS or refractory anemia with excess blasts (RAEB) who are eligible for allogeneic SCT because of controversial evidence on the role of such therapies. Yet, while treatment with hypomethylating agents (HMAs) has a critical limitation in eradicating MDS clones, the use of HMA treatment as a bridge to allogeneic SCT has become a focus with the hope of improving the SCT outcome based on the chance of achieving complete remission or reducing the blast percentage safely and effectively before allogeneic SCT. However, a consensus needs to be established on the use of HMAs as a bridging therapy for high-risk MDS or RAEB. Thus, the Korean AML/MDS working party group surveyed 34 Korean MDS experts on their bridging therapies for high-risk MDS. Accordingly, this paper presents the survey questionnaire and resulting data, along with a summary of the consensus and related recommendations regarding strategies using HMA treatment and allogeneic SCT based on reported studies and the current survey results. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Plasma Lens for Muon and Neutrino Beams

    Science.gov (United States)

    Kahn, Stephen; Korenev, Sergey; Bishai, Mary; Diwan, Milind; Gallardo, Juan; Hershcovitch, Ady; Johnson, Brant

    2008-04-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-current lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. A plasma lens has additional advantage: larger axial current than horns, minimal neutrino contamination during antineutrino running, and negligible pion absorption or scattering. Results from particle simulations using a plasma lens will be presented.

  2. Allogeneic stem cell transplantation in acute myeloid leukemia

    Directory of Open Access Journals (Sweden)

    Natasha Ali

    2012-11-01

    Full Text Available We report a case series of 12 patients with acute myeloid leukemia who underwent allogeneic stem cell transplant with a matched related donor. Male to female ratio was 1:1. The main complication post-transplant was graft-versus-host disease (n=7 patients. Transplant-related mortality involved one patient; cause of death was multi-organ failure. After a median follow up of 36.0±11.3 months, overall survival was 16%.

  3. Allogeneic fetal stem cell transplantation to child with psychomotor retardation: A case report

    Directory of Open Access Journals (Sweden)

    Dajić Katerina

    2016-01-01

    Full Text Available Introduction. The consequences of autologous and allogeneic stem cell transplantation (stem cells of hematopoiesis, applied in adults and children suffering from leukemia or some other malignant disease, are well-known and sufficiently recognizable in pediatric clinical practice regardless of the indication for the treatment. However, the efficacy of fetal stem cell transplantation is unrecognizable when the indications are psychomotor retardation and epilepsy. Case Outline. With the exception of neurological psychiatric problems, a boy aged 9.5 years was in good general health before transplantation with allogeneic fetal stem cells. The main aim of allogeneic fetal stem cell transplantation was treatment of psychomotor retardation and epilepsy. After 13 months of treatment, he was admitted to hospital in a very serious, life-threatening condition due to sepsis and severe pleuropneumonia. The humoral immunity in the boy was adequate, unlike cellular immunity. The immune imbalance in terms of predominance of T-suppressor lymphocytes contributes to delayed and late development of sepsis and severe pleuropneumonia. The boy still shows the same severity of psychomotor retardation, dyslalia, epilepsy, strabismus and amblyopia. Conclusion. Implementation of fetal stem cell therapy for unconfirmed indications abuses the therapeutic approach, harms patients, misleads parents, and brings financial harm to the healthcare system of any country, including Serbia.

  4. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  5. Fungemia due to Rhodotorula mucilaginosa after allogeneic hematopoietic stem cell transplantation.

    Science.gov (United States)

    Mori, T; Nakamura, Y; Kato, J; Sugita, K; Murata, M; Kamei, K; Okamoto, S

    2012-02-01

    Rhodotorula species have been increasingly recognized as emerging pathogens, particularly in immunocompromised patients. We herein report on a patient with myelodysplastic syndrome who developed fungemia due to Rhodotorula mucilaginosa after allogeneic hematopoietic stem cell transplantation (HSCT) from an unrelated donor. He developed severe acute graft-versus-host disease requiring high-dose steroids, and had serially been administered fluconazole and micafungin for the prophylaxis of fungal infection. Although several cases of Rhodotorula infection after HSCT have been reported, all of them were recipients of autologous HSCT, not allogeneic HSCT. A review of all the reported cases of Rhodotorula infection after HSCT revealed that all patients had received fluconazole or echinocandins before the onset of infection. The findings suggest that Rhodotorula species could be causative yeasts, particularly in patients receiving fluconazole or echinocandins, both of which are inactive against the species. © 2011 John Wiley & Sons A/S.

  6. DAS181 Treatment of Severe Parainfluenza Virus 3 Pneumonia in Allogeneic Hematopoietic Stem Cell Transplant Recipients Requiring Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    B. Dhakal

    2016-01-01

    Full Text Available Parainfluenza virus (PIV may cause life-threatening pneumonia in allogeneic hematopoietic stem cell transplant (HSCT recipients. Currently, there are no proven effective therapies. We report the use of inhaled DAS181, a novel sialidase fusion protein, for treatment of PIV type 3 pneumonia in two allogeneic hematopoietic SCT recipients with respiratory failure.

  7. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  8. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  9. Role of Aquaporin 0 in lens biomechanics

    International Nuclear Information System (INIS)

    Sindhu Kumari, S.; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G.; Menon, Anil G.; Mathias, Richard T.; Varadaraj, Kulandaiappan

    2015-01-01

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5 −/− ), AQP0 KO (heterozygous KO: AQP0 +/− ; homozygous KO: AQP0 −/− ; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0 +/− lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to

  10. Anti-Donor Immune Responses Elicited by Allogeneic Mesenchymal Stem Cells and Their Extracellular Vesicles: Are We Still Learning?

    Directory of Open Access Journals (Sweden)

    Paul Lohan

    2017-11-01

    Full Text Available Mesenchymal stromal cells (MSC have been used to treat a broad range of disease indications such as acute and chronic inflammatory disorders, autoimmune diseases, and transplant rejection due to their potent immunosuppressive/anti-inflammatory properties. The breadth of their usage is due in no small part to the vast quantity of published studies showing their ability to modulate multiple immune cell types of both the innate and adaptive immune response. While patient-derived (autologous MSC may be the safer choice in terms of avoiding unwanted immune responses, factors including donor comorbidities may preclude these cells from use. In these situations, allogeneic MSC derived from genetically unrelated individuals must be used. While allogeneic MSC were initially believed to be immune-privileged, substantial evidence now exists to prove otherwise with multiple studies documenting specific cellular and humoral immune responses against donor antigens following administration of these cells. In this article, we will review recent published studies using non-manipulated, inflammatory molecule-activated (licensed and differentiated allogeneic MSC, as well as MSC extracellular vesicles focusing on the immune responses to these cells and whether or not such responses have an impact on allogeneic MSC-mediated safety and efficacy.

  11. Activated allogeneic NK cells preferentially kill poor prognosis B-cell chronic lymphocytic leukemia cells

    Directory of Open Access Journals (Sweden)

    Diego Sanchez-Martinez

    2016-10-01

    Full Text Available Mutational status of TP53 together with expression of wild type (wt IGHV represents the most widely accepted biomarkers, establishing a very poor prognosis in B-cell chronic lymphocytic leukemia (B-CLL patients. Adoptive cell therapy using allogeneic HLA mismatched Natural Killer (NK cells has emerged as an effective and safe alternative in the treatment of acute myeloid and lymphoid leukemias that do not respond to traditional therapies. We have described that allogeneic activated NK cells eliminate hematological cancer cell lines with multidrug resistance acquired by mutations in the apoptotic machinery. This effect depends on the activation protocol, being B-lymphoblastoid cell lines (LCLs the most effective stimulus to activate NK cells. Here we have further analyzed the molecular determinants involved in allogeneic NK cell recognition and elimination of B-CLL cells, including the expression of ligands of the main NK cell activating receptors (NKG2D and NCRs and HLA mismatch. We present preliminary data suggesting that B-CLL susceptibility significantly correlates with HLA mismatch between NK cell donor and B-CLL patient. Moreover, we show that the sensitivity of B-CLL cells to NK cells depends on the prognosis based on TP53 and IGHV mutational status. Cells from patients with worse prognosis (mutated TP53 and wt IGHV are the most susceptible to activated NK cells. Hence, B-CLL prognosis may predict the efficacy of allogenic activated NK cells and, thus, NK cell transfer represents a good alternative to treat poor prognosis B-CLL patients who present a very short life expectancy due to lack of effective treatments.□

  12. Cionni ring and in-the-bag intraocular lens implantation for subluxated lenses: a prospective case series.

    Science.gov (United States)

    Vasavada, Abhay R; Praveen, Mamidipudi R; Vasavada, Viraj A; Yeh, Ru-Yin; Srivastava, Samaresh; Koul, Archana; Trivedi, Rupal H

    2012-06-01

    To report the intraoperative performance and postoperative outcomes of the Cionni-modified capsule tension ring (CTR) implantation in eyes with subluxated lenses. Prospective, observational case series. This study was carried out at Iladevi Cataract & IOL Research Centre, Ahmedabad, India. The study population comprised 41 eyes with subluxated lenses that underwent lens extraction, capsular bag fixation with modified CTR, and in-the-bag single-piece AcrySof intraocular lens (IOL) implantation. Main outcome measures were intraoperative performance and postoperative best-corrected visual acuity (BCVA), IOL centration, and complications. The mean age was 29.46 ± 16.16 years (3-68 years). Mean extent of subluxation was 6.1 ± 1.0 clock hours. Preoperatively, vitreous was detected in the anterior chambers of 5 eyes (12.2%). Two-port anterior chamber vitrectomy was performed in 2 eyes. Mean follow-up was 45.8 ± 2.9 months. Mean preoperative BCVA was 0.66 ± 0.22 logMAR (35 eyes). Mean postoperative BCVA at final follow-up was 0.33 ± 0.21 logMAR (41 eyes) (P IOL decentration was noted and repositioning was required in 2 eyes. Posterior capsule opacification developed in 14 eyes (34.2%); 12 eyes (29.3%) required Nd:YAG capsulotomy. Other complications included cystoid macular edema in 1 eye (2.4%), posterior synechiae in 1 eye (2.4%), and retinal detachment in 1 eye (2.4%). In-the-bag implantation of a Cionni-modified CTR with IOL appears to be a safe option in eyes with subluxated cataract, ensuring a stable IOL with few complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Correlation and Agreement of Handheld Spirometry with Laboratory Spirometry in Allogeneic Hematopoietic Cell Transplant Recipients.

    Science.gov (United States)

    Cheng, Guang-Shing; Campbell, Angela P; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M; Englund, Janet A; Chien, Jason W; Boeckh, Michael

    2016-05-01

    Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplant (HCT) recipients who are at increased risk for late noninfectious pulmonary complications, including bronchiolitis obliterans syndrome. We evaluated the use of handheld spirometry in this population. Allogeneic HCT recipients enrolled in a single-center observational trial performed weekly spirometry with a handheld spirometer for 1 year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: before transplantation, at day 80 after transplantation, and at 1 year after transplantation. Correlation between the 2 methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. A total of 437 subjects had evaluable pulmonary function tests. Correlation for forced expiratory volume in 1 second (FEV1) was r = .954 (P spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. Copyright © 2016 American Society for Blood and Marrow Transplantation. All rights reserved.

  14. Compensating additional optical power in the central zone of a multifocal contact lens forminimization of the shrinkage error of the shell mold in the injection molding process.

    Science.gov (United States)

    Vu, Lien T; Chen, Chao-Chang A; Lee, Chia-Cheng; Yu, Chia-Wei

    2018-04-20

    This study aims to develop a compensating method to minimize the shrinkage error of the shell mold (SM) in the injection molding (IM) process to obtain uniform optical power in the central optical zone of soft axial symmetric multifocal contact lenses (CL). The Z-shrinkage error along the Z axis or axial axis of the anterior SM corresponding to the anterior surface of a dry contact lens in the IM process can be minimized by optimizing IM process parameters and then by compensating for additional (Add) powers in the central zone of the original lens design. First, the shrinkage error is minimized by optimizing three levels of four IM parameters, including mold temperature, injection velocity, packing pressure, and cooling time in 18 IM simulations based on an orthogonal array L 18 (2 1 ×3 4 ). Then, based on the Z-shrinkage error from IM simulation, three new contact lens designs are obtained by increasing the Add power in the central zone of the original multifocal CL design to compensate for the optical power errors. Results obtained from IM process simulations and the optical simulations show that the new CL design with 0.1 D increasing in Add power has the closest shrinkage profile to the original anterior SM profile with percentage of reduction in absolute Z-shrinkage error of 55% and more uniform power in the central zone than in the other two cases. Moreover, actual experiments of IM of SM for casting soft multifocal CLs have been performed. The final product of wet CLs has been completed for the original design and the new design. Results of the optical performance have verified the improvement of the compensated design of CLs. The feasibility of this compensating method has been proven based on the measurement results of the produced soft multifocal CLs of the new design. Results of this study can be further applied to predict or compensate for the total optical power errors of the soft multifocal CLs.

  15. In vitro evaluation of allogeneic bone screws for use in internal fixation of transverse fractures created in proximal sesamoid bones obtained from equine cadavers.

    Science.gov (United States)

    Sasaki, Naoki; Takakuwa, Jun; Yamada, Haruo; Mori, Ryuji

    2010-04-01

    To evaluate effectiveness of allogeneic bone screws and pins for internal fixation of midbody transverse fractures of equine proximal sesamoid bones (PSBs) in vitro. 14 forelimbs from cadavers of 3-year-old Thoroughbreds. Allogeneic cortical bone fragments were collected from the limbs of a male Thoroughbred, and cortical bone screws were prepared from the tissue by use of a precision desktop microlathe programmed with the dimensions of a metal cortical bone screw. A midbody transverse osteotomy of each PSB was performed by use of a bone-shaping oscillating saw and repaired via 1 of 3 internal fixation techniques: 1 allogeneic bone screw with 1 allogeneic bone pin (type I; n = 6 PSBs), 2 allogeneic bone screws (type II; 8), or 1 stainless steel cortical bone screw (control repair; 6). Mechanical tension measurements were obtained by use of a commercially available materials testing system. Mean +/- SD tensile strength (TS) was 668.3 +/- 216.6 N for type I repairs, 854.4 +/- 253.2 N for type II repairs, and 1,150.0 +/- 451.7 N for control repairs. Internal fixation of PSB fractures by the use of allogeneic bone screws and bone pins was successful. Although mean TS of control repairs with stainless steel cortical bone screws was greater than the mean TS of type I and type II repairs, the difference between type II and control repairs was not significant. Allogeneic screws may advance healing and result in fewer complications in a clinical setting.

  16. Titanium implant insertion into dog alveolar ridges augmented by allogenic material

    DEFF Research Database (Denmark)

    Pinholt, E M; Haanaes, H R; Donath, K

    1994-01-01

    The purpose of this investigation was to evaluate whether titanium endosseous implants would osseointegrate in dog alveolar ridges augmented by allogenic material. In 8 dogs en bloc resection, including 2 pre-molars, was performed bilaterally in the maxilla and the mandible. After a healing period...

  17. Similar effect of autologous and allogeneic cell therapy for ischemic heart disease : Systematic review and meta-analysis of large animal studies

    NARCIS (Netherlands)

    Jansen of Lorkeers, Sanne J.; Eding, Joep Egbert Coenraad; Vesterinen, Hanna Mikaela; van der Spoel, Tycho Ids Gijsbert; Sena, Emily Shamiso; Duckers, Henricus Johannes; Doevendans, Pieter Adrianus; Macleod, Malcolm Robert; Chamuleau, Steven Anton Jozef

    2015-01-01

    Rationale: In regenerative therapy for ischemic heart disease, use of both autologous and allogeneic stem cells has been investigated. Autologous cell can be applied without immunosuppression, but availability is restricted, and cells have been exposed to risk factors and aging. Allogeneic cell

  18. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  19. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  20. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  1. Stretchable Binary Fresnel Lens for Focus Tuning

    NARCIS (Netherlands)

    Li, X.; Wei, L.; Poelma, R.H.; Vollebregt, S.; Wei, J.; Urbach, Paul; Sarro, P.M.; Zhang, G.Q.

    2016-01-01

    This paper presents a tuneable binary amplitude Fresnel lens produced by wafer-level microfabrication. The Fresnel lens is fabricated by encapsulating lithographically defined vertically aligned carbon nanotube (CNT) bundles inside a polydimethyl-siloxane (PDMS) layer. The composite lens material

  2. Progression and CSF Inflammation after Eradication of Oligoclonal Bands in an MS Patient Treated with Allogeneic Hematopoietic Cell Transplantation for Follicular Lymphoma

    DEFF Research Database (Denmark)

    Braendstrup, P; Langkilde, Annika; Schreiber, K

    2012-01-01

    Allogeneic hematopoietic cell transplantation (allo-HCT) has been proposed as treatment for multiple sclerosis (MS) and other autoimmune diseases.......Allogeneic hematopoietic cell transplantation (allo-HCT) has been proposed as treatment for multiple sclerosis (MS) and other autoimmune diseases....

  3. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  4. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  5. Prevention of after-cataract by application of heparin treatment of capsular tension ring in Marfan syndrome and subluxation of lens

    Directory of Open Access Journals (Sweden)

    Zhong-Qing Li

    2013-08-01

    Full Text Available AIM: To investigate the effect of heparin treatment on capsular tension ring(CTRin the prevention of after-cataract postoperative patients with Marfan syndrome and subluxation of lens.METHODS: Totally 34 cases(56 eyeswere divided randomly into experimental and control groups. Preoperative heparin 12500 units was added to 500mL Ringer's infusion, and CTR was dealt with heparin stock solution soak for 20 minutes in experimental group; there was no any drugs in the control group's solution, and CTR was not dealt with heparin. Postoperative IOP, anterior chamber reaction, corneal edema, IOL position, posterior capsular opacification were observed.RESULTS: There was statistically significant difference in the posterior capsular opacification between the heparin group(13.3%and the contral group no-heparin(69.2%(PCONCLUSION: The present results indicate that there is the preventive effect on posterior capsular opacification by CTR soaked in heparin in postoperative patients with Marfan syndrome and subluxation of lens, thus contributing to the recovery of visual function.

  6. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  7. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Directory of Open Access Journals (Sweden)

    Zhonghao Wang

    Full Text Available To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM images using Photoshop software and to assess its intraobserver and interobserver reproducibility.Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA, posterior chamber area (PCA, iris cross-section area (ICA and angle recess area (ARA were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV, and intraclass correlation coefficient (ICC.All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001.Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  8. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  9. Storage and allogeneic transplantation of peripheral nerve using a green tea polyphenol solution in a canine model

    Directory of Open Access Journals (Sweden)

    Noguchi Takashi

    2010-11-01

    Full Text Available Abstract Background In our previous study, allogeneic-transplanted peripheral nerve segments preserved for one month in a polyphenol solution at 4°C could regenerate nerves in rodents demonstrated the same extent of nerve regeneration as isogeneic fresh nerve grafts. The present study investigated whether the same results could be obtained in a canine model. Methods A sciatic nerve was harvested from a male beagle dog, divided into fascicules of Sry and β-actin to investigate whether cells of donor origin remained in the allogeneic nerve segments. FK506 concentration was measured in blood samples taken before the animals were killed. Results The total myelinated axon numbers and amplitudes of the muscle action potentials correlated significantly with the blood FK506 concentration. Few axons were observed in the allogeneic-transplanted nerve segments in the PA0.025 group. PCR showed clear Sry-specific bands in specimens from the PA0.1 and PA0.05 groups but not from the PA0.025 group. Conclusions Successful nerve regeneration was observed in the polyphenol-treated nerve allografts when transplanted in association with a therapeutic dose of FK506. The data indicate that polyphenols can protect nerve tissue from ischemic damage for one month; however, the effects of immune suppression seem insufficient to permit allogeneic transplantation of peripheral nerves in a canine model.

  10. The Role of Aquaporins in Ocular Lens Homeostasis

    Science.gov (United States)

    Schey, Kevin L.; Petrova, Rosica S.; Gletten, Romell B.; Donaldson, Paul J.

    2017-01-01

    Aquaporins (AQPs), by playing essential roles in the maintenance of ocular lens homeostasis, contribute to the establishment and maintenance of the overall optical properties of the lens over many decades of life. Three aquaporins, AQP0, AQP1 and AQP5, each with distinctly different functional properties, are abundantly and differentially expressed in the different regions of the ocular lens. Furthermore, the diversity of AQP functionality is increased in the absence of protein turnover by age-related modifications to lens AQPs that are proposed to alter AQP function in the different regions of the lens. These regional differences in AQP functionality are proposed to contribute to the generation and directionality of the lens internal microcirculation; a system of circulating ionic and fluid fluxes that delivers nutrients to and removes wastes from the lens faster than could be achieved by passive diffusion alone. In this review, we present how regional differences in lens AQP isoforms potentially contribute to this microcirculation system by highlighting current areas of investigation and emphasizing areas where future work is required. PMID:29231874

  11. 21 CFR 886.1380 - Diagnostic condensing lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...

  12. anomalous left anterior cerebral artery with hypoplastic right anterior ...

    African Journals Online (AJOL)

    2018-02-28

    Feb 28, 2018 ... We report an extremely rare anomalous variation of left anterior cerebral artery arising from the ... paraclinoid internal carotid artery and right ... Studies on the arteries of the brain: II-The anterior cerebral artery: Some anatomic ...

  13. Bacterial transmission from lens storage cases to contact lenses-Effects of lens care solutions and silver impregnation of cases.

    Science.gov (United States)

    Vermeltfoort, Pit B J; Hooymans, Johanna M M; Busscher, Henk J; van der Mei, Henny C

    2008-10-01

    The killing efficacies of multipurpose lens care solutions on planktonic and biofilm bacteria grown in polypropylene contact lens storage cases with and without silver impregnation and effects on bacterial transmission from storage cases to silicone hydrogel contact lenses were investigated. For transmission studies, biofilms of Staphylococcus aureus 835 or Pseudomonas aeruginosa no. 3 were grown on lens storage cases and incubated with a contact lens in different multipurpose lens care solutions (Opti-Free(R)Express(R), ReNu(R) MultiPlus(R), and SoloCare Aquatrade mark) or 0.9% NaCl. In addition, planktonic bacteria were directly suspended in multipurpose solutions and their killing efficacies were determined. The numbers of transmitted live and dead bacteria on the lenses were measured using a combination of plate counting and fluorescence microscopy. The highest killing efficacies were shown by Opti-Free(R) Express(R) for planktonic as well as for biofilm bacteria. Silver impregnation of lens cases in combination with the prescribed solution increased the killing efficacy for P. aeruginosa in biofilms, whereas effects for S. aureus were minor. Lowest numbers of live and dead bacteria were transmitted to a lens in Opti-Free(R) Express(R) multipurpose solution, with no significant differences between lens types and no effects of silver impregnation. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2008. (c) 2008 Wiley Periodicals, Inc.

  14. Allogeneic bone marrow transplantation in adults after fractionated body irradiation and high dose cyclophosphamide

    International Nuclear Information System (INIS)

    Brinch, L.; Evensen, S.A.; Albrechtsen, D.; Egeland, T.; Solheim, B.G.; Rollag, H.; Naalsund, A.; Jacobsen, A.B.

    1991-01-01

    The authors present short and long-term results of allogeneic bone marrow transplantation after hyper-fractionated total body irradiation and high dose cyclophosphamide in ten patients treated for leukaemia during th period 1985-89. Three patients died from complications connected to the transplantation, while seven are living free from leukaemia 18 to 59 months after transplantation. Two patients need treatment for chronic graft versus host disease. Allogeneic bone marrow transplantation is expensive and risky. Close cooperation between clinicians and laboratory specialists is essential. The treatment increases long term survival and probably cures certain patients with leukaemia. Some of the patients will need treatment for chronic graft versus host disease and other late sequelae. 19 refs., 2 tabs

  15. Electron beam irradiation to the allogeneic, xenogenic and synthetic bone materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soung Min; Park, Min Woo; Jeong, Hyun Oh [School of Dentistry Seoul National University, Seoul (Korea, Republic of); and others

    2013-07-01

    For the development of the biocompatible bony regeneration materials, allogenic, xenogenic and synthetic bone were irradiated by electron beam to change the basic components and structures. For the efficient electron beam irradiating condition of these allogenic, xenogenic and artificial bone substitutes, the optimal electron beam energy and their individual dose were established, to maximize the bony regeneration capacity. Commercial products of four allogenic bones, such as Accell (ISOTIS OrthogBiologics Co., USA), Allotis (Korea Bone Bank Co., Korea), Oragraft (LifeNet Co., USA), and Orthoblast (Integra Orthobiologics Inc., USA), six xenogenic bones, such as BBP (OscoTec Co., Korea), Bio-cera (OscoTec Co., Korea), Bio-oss (Geistlich Pharma AG, Switzerland), Indu-cera (OscoTec Co., Korea), OCS-B (Nibec Co., Korea), and OCS-H (Nibec Co., Korea), and six synthetic bones, such as BMP (Couellmedi Co., Korea), BoneMedik (Meta Biomed Co., Korea), Bone plus (Megagen Co., Korea), MBCP (Biomatlante Co., France), Osteon (Genoss Co., Korea), and Osteogen (Impladent LTD., USA), were used. We used 1.0 and 2.0 MeV superconduction accelerator, and/or microtrone with different individual 60, 120 kGy irradiation dose. Different dose irradiated specimens were divided 6 portions each, so total 360 groups were prepared. 4 portions were analyzed each by elementary analysis using FE-SEM (Field Emission Scanning Microscopy) and another 2 portions were grafted to the calvarial defect of Sprague-Dawley rat, following histologic, immunohistochemical analysis and TEM study were processed at the 8th and 16th weeks, in vivo. This work was supported by the National Research Foundation of Korea(NRF) grant funded by the Korea government(MEST)

  16. Personalización de las constantes en las fórmulas de cálculo de la lente intraocular Personalization of constants in the intraocular lens calculation formulas

    Directory of Open Access Journals (Sweden)

    Anneé Miranda Carracedo

    2012-12-01

    Full Text Available Objetivo: personalizar las constantes A, factor cirujano y profundidad de la cámara anterior para las fórmulas de cálculo de la lente intraocular en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" de mayo de 2007 a enero de 2011. Métodos: se realizó un estudio descriptivo retrospectivo donde se estudiaron las constantes A, factor cirujano y profundidad de la cámara anterior. También se evaluó la longitud axial preoperatoria por IOL Master, la mejor agudeza visual sin corrección, el componente esférico esperado, el componente esférico obtenido y los resultados refractivos. Resultados: las constantes optimizadas por interferometría de coherencia parcial son diferentes a las propuestas por los fabricantes de las lentes intraoculares. Estas constantes personalizadas para cada cirujano no mostraron diferencias significativas. Las constantes optimizadas según las longitudes axiales, tienen diferencias significativas en los 3 grupos de estudio. La diferencia entre la lente intraocular implantada y la propuesta con las nuevas constantes resultó menor de 1 D de error en 83,1 % de los pacientes. El 75,4 % quedó bien corregido en relación con la diferencia entre la refracción esperada y la obtenida. Conclusiones: las constantes optimizadas por interferometría de coherencia parcial resultan más elevadas que las propuestas por el fabricante. La optimización de estas en el cálculo de la lente permite, de acuerdo a las características individuales de cada ojo (longitud axial, usar la fórmula adecuada e incrementa la predictibilidad de los resultados refractivos posoperatorios.Objective: to personalize the A, surgeon factor and anterior chamber depth constants for intraocular lens calculation formulas in the cataract surgery at the “Ramón Pando Ferrer” Cuban Ophthalmological Institute from May 2007 to January 2011. Method: a retrospective and descriptive study was made to study the A constant

  17. Wide-range tunable magnetic lens for tabletop electron microscope

    International Nuclear Information System (INIS)

    Chang, Wei-Yu; Chen, Fu-Rong

    2016-01-01

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  18. Wide-range tunable magnetic lens for tabletop electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Yu; Chen, Fu-Rong, E-mail: fchen1@me.com

    2016-12-15

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  19. Late taste disorders in bone marrow transplantation: clinical evaluation with taste solutions in autologous and allogeneic bone marrow recipients.

    Science.gov (United States)

    Marinone, M G; Rizzoni, D; Ferremi, P; Rossi, G; Izzi, T; Brusotti, C

    1991-01-01

    The aim of this work was to determine the type and the significance of taste disorders in allogeneic bone marrow transplanted patients. In a retrospective study the taste threshold of a cohort of 15 allogeneic bone marrow transplanted patients, 4-51 months after transplantation (mean: 30.6 +/- 15.8), was compared to the taste threshold of 8 autologous bone marrow recipients, 4-48 months after transplantation (mean: 24.12 +/- 12.18), and to the taste threshold of a group of 20 consecutive normal subjects. Allogeneic bone marrow transplanted patients showed a significant hypogeusia for salt (Pearson's chi square p = 0.0002; Yates' correction p = 0.0007) and sour (Pearson's chi square p = 0.001; Yates' correction p = 0.008). No significant variations were observed for sweet and bitter. Autologous bone marrow recipients did not show any significant variation of taste acuity for sweet, salt or sour; a constant reduction of the taste threshold for bitter was observed, but the values were not significantly different from normal (Pearson's chi square p = 0.47; Yates' correction p = 0.83). So, late and selective taste disorders are observed in allogeneic bone marrow transplanted patients. Since the severity of the disorders is not strictly related to the severity of chronic oral G.V.H.D., taste analysis could discover the slightest, clinically undetectable cases of chronic oral G.V.H.D. The mechanism of immune aggression on the sensorial taste cells is poorly understood. Further trials are needed to define variations of taste acuity not only after allogeneic bone marrow transplantation, but also in systemic immune diseases.

  20. Allogeneic BMT and patient eligibility based on psychosocial criteria: a survey of BMT professionals.

    Science.gov (United States)

    Foster, L W; McLellan, L J; Rybicki, L A; Dabney, J; Welsh, E; Bolwell, B J

    2006-01-01

    BMT professionals were compared regarding their willingness to proceed with allogeneic BMT given select psychosocial issues. A questionnaire was sent to 660 physician members of ASBMT, 92 social work members of BMT Special Interest Group, Association of Oncology Social Work, and 626 nurse members of BMT Special Interest Group, Oncology Nursing Society; 597 responded with a response rate of 43.5%. Items included background information, followed by 17 case vignettes; each represented a different psychosocial issue to which respondents indicated whether or not they would recommend proceeding with allogeneic BMT. In every vignette, at least 10% of respondents indicated they would not proceed. In six vignettes, at least 64% indicated do not proceed: suicidal ideation (86.8%), uses addictive illicit drugs (81.7%), history of noncompliance (80.5%), no lay caregiver (69.3%), alcoholic (64.8%), and mild dementia/Alzheimer's (64.4%). In 10 vignettes, at least 73% indicated proceed. On four vignettes, professional subgroups differed in their recommendation on whether or not to proceed with allogeneic BMT. Qualitative data suggest that this decision is contingent on the perceived acuity, severity, and currency of the psychosocial issue, patient ability to comply with treatment given the issue, and its manageability as a risk factor for treatment related vulnerability and outcomes.

  1. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2015-06-01

    Full Text Available AIM:To evaluate the prediction error in intraocular lens (IOL power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP.METHODS:Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany. In all cases, an adjusted IOL power (PIOLadj was calculated based on Gaussian optics using a variable keratometric index value (nkadj for the estimation of the corneal power (Pkadj and on a new value for ELP (ELPadj obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay Ⅰ.RESULTS:PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05. In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D and limits of agreement (of 1.47 and -1.61 D when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01 and was found to be dependent on axial length, anterior chamber depth and Pkadj.CONCLUSION:Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  2. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  3. Allogeneic stem cell transplantation for advanced acute promyelocytic leukemia in the ATRA and ATO era

    Science.gov (United States)

    Ramadan, Safaa M.; Di Veroli, Ambra; Camboni, Agnese; Breccia, Massimo; Iori, Anna Paola; Aversa, Franco; Cupelli, Luca; Papayannidis, Cristina; Bacigalupo, Andrea; Arcese, William; Lo-Coco, Francesco

    2012-01-01

    The role of allogeneic stem cell transplant in advanced acute promyelocytic leukemia patients who received standard first- and second-line therapy is still unknown. We report the outcome of 31 acute promyelocytic leukemia patients (median age 39 years) who underwent allogeneic transplant in second remission (n=15) or beyond (n=16). Sixteen patients were real-time polymerase chain reaction positive and 15 negative for PML/RARA pre-transplant. The 4-year overall survival was 62% and 31% for patients transplanted in second remission and beyond, respectively (P=0.05), and 64% and 27% for patients with pre-transplant negative and positive real-time polymerase chain reaction, respectively (P=0.03). The 4-year cumulative incidence of relapse was 32% and 44% for patients transplanted in second remission and beyond, respectively (P=0.37), and 30% and 47% for patients transplanted with negative and positive real-time polymerase chain reaction, respectively (P=0.30). Transplant-related mortality was 19.6%. In conclusion, allogeneic transplant is effective in advanced acute promyelocytic leukemia in the all-trans-retinoic acid and arsenic trioxide era, and should be considered once relapse is diagnosed. PMID:22689684

  4. Adaptive mechanical-wetting lens actuated by ferrofluids

    Science.gov (United States)

    Cheng, Hui-Chuan; Xu, Su; Liu, Yifan; Levi, Shoshana; Wu, Shin-Tson

    2011-04-01

    We report an adaptive mechanical-wetting lens actuated by ferrofluids. The ferrofluids works like a piston to pump liquids in and out from the lens chamber, which in turn reshapes the lens curvature and changes the focal length. Both positive and negative lenses are demonstrated experimentally. The ferrofluid-actuated mechanical-wetting lens exhibits some attractive features, such as high resolution, fast response time, low power consumption, simple structure and electronic control, weak gravity effect, and low cost. Its potential applications in medical imaging, surveillance, and commercial electronics are foreseeable.

  5. Numerical studies on the ramped density plasma lens

    International Nuclear Information System (INIS)

    Williams, R.L.; Katsouleas, T.

    1992-01-01

    We consider the so-called adiabatic plasma lens when the plasma density is ramped too quickly to be considered adiabatic. The lens length can be much shorter in such a case, but the final spot size is shown to be larger by a factor of √1+α 2 than for a slowly ramped plasma lens with the same initial and final density (where α=-β'/2 is proportional to the plasma density gradient). We find that the final spot size is the same whether or not the Courant-Snyder parameters of the beam (α and β) are matched to the lens. However, matched beams allow the plasma density to be lower while unmatched beams allow the lens to be shorter (for the same α and for the same final to initial plasma density ratio). Finally, we find that a smaller spot size can be obtained for a given lens length and density ratio by starting at smaller α and increasing α along the lens

  6. LASL lens design procedure: simple, fast, precise, versatile

    International Nuclear Information System (INIS)

    Brixner, B.

    1978-11-01

    The Los Alamos Scientific Laboratory general-purpose lens design procedure optimizes specific lens prescriptions to obtain the smallest possible image spots and therefore near-spherical wave fronts of light converging on all images in the field of view. Optical image errors are analyzed in much the same way that they are measured on the optical bench. This lens design method is made possible by using the full capabilities of large electronic computers. First, the performance of the whole lens is sampled with many precisely traced skew rays. Next, lens performance is analyzed with spot diagrams generated by the many rays. Third, lens performance is optimized with a least squares system aimed at reducing all image errors to zero. This statistical approach to lens design uses skew rays and precisely measured ray deviations from ideal image points to achieve greater accuracy than was possible with the classical procedure, which is based on approximate expressions derived from simplified ray traces developed for pencil-and-paper calculations

  7. Anterior segment dysgenesis associated with Williams-Beuren syndrome: a case report and review of the literature.

    Science.gov (United States)

    Todorova, Margarita G; Grieshaber, Matthias C; Cámara, Rafael J A; Miny, Peter; Palmowski-Wolfe, Anja M

    2014-05-21

    Williams-Beuren syndrome is characterized by mild mental retardation, specific neurocognitive profile, hypercalcemia during infancy, distinctive facial features and cardiovascular diseases. We report on complete ophthalmologic, sonographic and genetic evaluation of a girl with a clinical phenotype of Williams-Beuren syndrome, associated with unilateral anterior segment dysgenesis and bilateral cleft of the soft and hard palate. These phenotypic features have not been linked to the haploinsufficiency of genes involved in the microdeletion. A term born girl presented at the initial examination with clouding of the right cornea. On ultrasound biomicroscopy the anterior chamber structures were difficult to differentiate, showing severe adhesions from the opacified cornea to the iris with a kerato-irido-lenticular contact to the remnant lens, a finding consistent with Peters' anomaly. Genetic analyses including FISH confirmed a loss of the critical region 7q11.23, usually associated with the typical Williams-Beuren syndrome. Microsatellite analysis showed a loss of about 2.36 Mb. A diagnosis of Williams-Beuren syndrome was made based on the microdeletion of 7q11.23. The unique features, including unilateral microphthalmia and anterior segment dysgenesis, were unlikely to be caused by the microdeletion. Arguments in favor of the latter are unilateral manifestation, as well as the fact that numerous patients with deletions of comparable or microscopically visible size have not shown similar manifestations.

  8. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients.

    Science.gov (United States)

    Sengor, Tomris; Kurna, Sevda Aydin; Aki, Suat; Ozkurt, Yelda

    2011-01-01

    The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients. Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units) and fluorosilicone methacrylate copolymer (Dk/t = 100 units) lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system. INDICATIONS FOR USING PBCL SYSTEM WERE: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0). Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3-12 months); thereafter they tolerated rigid lenses alone except for 2 patients. The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.

  9. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  10. Informed consent: cultural and religious issues associated with the use of allogeneic and xenogeneic mesh products.

    Science.gov (United States)

    Jenkins, Eric D; Yip, Michael; Melman, Lora; Frisella, Margaret M; Matthews, Brent D

    2010-04-01

    Our aim was to investigate the views of major religions and cultural groups regarding the use of allogeneic and xenogeneic mesh for soft tissue repair. We contacted representatives from Judaism, Islam, Buddhism, Hinduism, Scientology, and Christianity (Baptists, Methodists, Seventh-Day Adventists, Catholics, Lutherans, Church of Jesus Christ of Latter-Day Saints, Evangelical, and Jehovah's Witnesses). We also contacted American Vegan and People for the Ethical Treatment of Animals (PETA). Standardized questionnaires were distributed to the religious and cultural authorities. Questions solicited views on the consumption of beef and pork products and the acceptability of human-, bovine-, or porcine-derived acellular grafts. Dietary restrictions among Jews and Muslims do not translate to tissue implantation restriction. Approximately 50% of Seventh-day Adventists and 40% of Buddhists practice vegetarianism, which may translate into a refusal of the use of xenogeneic tissue. Some Hindus categorically prohibit the use of human tissue and animal products; others allow the donation and receipt of human organs and tissues. PETA is opposed to all uses of animals, but not to human acellular grafts or organ transplantation. Some vegans prefer allogeneic to xenogeneic tissue. Allogeneic and xenogeneic acellular grafts are acceptable among Scientologists, Baptists, Lutherans, Evangelicals, and Catholics. Methodists, Jehovah's Witnesses, and The Church of Jesus Christ of Latter-Day Saints leave the decision up to the individual. Knowledge of religious and cultural preferences regarding biologic mesh assists the surgeon in obtaining a culturally sensitive informed consent for procedures involving acellular allogeneic or xenogeneic grafts. Copyright (c) 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    Science.gov (United States)

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  12. Orbiting objective lens telescope system and method

    International Nuclear Information System (INIS)

    Crooks, J.W. Jr.

    1984-01-01

    A large objective lens is placed in a highly eccentric orbit about the earth. The orbit and orientation of the lens are carefully chosen so that it focuses light or other radiation from a preselected astronomical object into an image which slowly moves across the surface of the earth. A row of optical sensing units is located on the surface of the earth so that the image focused by the orbiting objective lens will travel substantially perpendicularly across the row during an observation. Output data generated from the sensing units may be multiplexed and fed to a real time processor which produces display signals. Each of the sensing units provides one scan line of the image being observed. The display signals are fed to a suitable display device which produces a picture of the preselected astronomical object. The objective lens may comprise a large flexible Fresnel zone plate or a flexible convex lens carried by a bicycle wheel-type supporting structure. The lens and supporting structure may be unfolded from compact cargo configurations and rotated after being placed into orbit

  13. Refractive error, ocular biometry, and lens opalescence in an adult population: the Los Angeles Latino Eye Study.

    Science.gov (United States)

    Shufelt, Chrisandra; Fraser-Bell, Samantha; Ying-Lai, Mei; Torres, Mina; Varma, Rohit

    2005-12-01

    To characterize age- and gender-related differences in refractive error, ocular biometry, and lens opalescence (NOP) in a population-based sample of adult Latinos. Also assessed were the determinants of age-related refractive differences. Participants in the Los Angeles Latino Eye Study (LALES), a population-based study of Latinos aged 40 years and more, underwent an ophthalmic examination, including ultrasonic measurements of axial length (AL), vitreous chamber depth (VCD), anterior chamber depth (ACD), lens thickness (LT), and noncycloplegic automated and subjective refraction. Corneal curvature/power (CP) was measured using an autorefractor. NOP was graded at the slit lamp by an ophthalmologist using the Lens Opacity Classification System II. Age- and gender-related differences were calculated. Multiple regression models were used to identify the determinants of age-related refractive differences. Of the 6357 LALES participants, 5588 phakic individuals with biometric data were included in this analysis. Older individuals had shallower ACDs, thicker lenses, more NOP, and more hyperopia compared to younger individuals (P or = 0.05). Women had significantly shorter AL, shallower ACD and VCD, than did men (P < or = 0.01). The strongest determinants of refractive error were AL (primarily VCD) and CP. NOP was a small but significant determinant of refractive error in older individuals. Age- and gender-related differences in ocular biometric, refractive error, and NOP measurements are present in adult Latinos. While the relative contribution of NOP in determining refractive error is small, it is greater in older persons compared to younger individuals.

  14. Rat silicone hydrogel contact lens model: effects of high- versus low-Dk lens wear.

    Science.gov (United States)

    Zhang, Yunfan; Gabriel, Manal M; Mowrey-McKee, Mary F; Barrett, Ronald P; McClellan, Sharon; Hazlett, Linda D

    2008-11-01

    This study used a rat contact lens (CL) model to test if high- versus low-Dk lens wear caused changes in (1) conjunctival Langerhans cell (LC) number or location; (2) Bcl-2 expression; and (3) infection risk. Female, Lewis rats wore a high- or low-Dk CL continuously for 2 weeks. Afterward, corneas were harvested and processed for ADPase activity to identify LCs, for immunostaining and for real time-polymerase chain reaction. Contact lens-wearing rats also were challenged with Pseudomonas aeruginosa by placing a bacterial-soaked CL on the eye followed by topical delivery of bacteria. After 48 hrs, slit lamp examination and real time-polymerase chain reaction were used to evaluate the corneal response. Conjunctival LC were significantly increased after low- versus high-Dk CL wear (PDk lens wearing group. Bcl-2 mRNA levels were significantly decreased in low- versus high-Dk CL wearing rats, while Bax, FasL, caspase 3, and caspase 9 levels were unchanged. Immunostaining for Bcl-2 showed fewer positively stained epithelial cells in the low- versus high-Dk lens wearing group. After bacterial challenge, 30% of low- versus none of the high-Dk CL wearing corneas became infected and showed increased mRNA levels for several proinflammatory cytokines/chemokines, inducible nitric oxide synthase and matrix metalloproteinase-9. Low- versus high-Dk or non-CL wear led to an increased number of conjunctival LC, decreased Bcl-2 levels, and increased the risk of bacterial infection.

  15. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    Czech Academy of Sciences Publication Activity Database

    Konvalina, Ivo; Müllerová, Ilona

    2011-01-01

    Roč. 645, č. 1 (2011), s. 55-59 ISSN 0168-9002 R&D Projects: GA ČR GAP102/10/1410; GA AV ČR IAA100650902; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : cathode lens * compound objective lens * aberration coefficients * spot size * field calculations Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.207, year: 2011

  16. Rabbit articular cartilage defects treated by allogenic chondrocyte transplantation

    OpenAIRE

    Boopalan, P. R. J. V. C.; Sathishkumar, Solomon; Kumar, Senthil; Chittaranjan, Samuel

    2006-01-01

    Articular cartilage defects have a poor capacity for repair. Most of the current treatment options result in the formation of fibro-cartilage, which is functionally inferior to normal hyaline articular cartilage. We studied the effectiveness of allogenic chondrocyte transplantation for focal articular cartilage defects in rabbits. Chondrocytes were cultured in vitro from cartilage harvested from the knee joints of a New Zealand White rabbit. A 3 mm defect was created in the articular cartilag...

  17. The Fourth Nagoya International Blood and Marrow Transplantation Symposium: new horizons in allogeneic hematopoietic cell transplantation--2001 revolution.

    Science.gov (United States)

    Sao, Hiroshi; Morishita, Yoshihisa

    2002-02-01

    In this symposium, we saw new horizons in allogeneic transplantation. Are these truly revolutionary? We do not yet know the answer. However, there is no question about the importance of allogeneic T cells. T cells are much more powerful than any pharmacological drug man has ever generated. The question is, how do we take the most advantage of their potential. Every participant was encouraged to search for good answers to this question until the next meeting.

  18. Analysis of the results of allogeneic hematopoietic stem cell transplantation depending on HLA matching of the unrelated donor / recipient pair

    Directory of Open Access Journals (Sweden)

    Ye. V. Kuzmich

    2015-01-01

    Full Text Available HLA matching of the donor / recipient pair is a major factor associated with the outcome of allogeneic stem cell transplantation. In the presentstudy we analyzed the risk of severe acute graft-versus-host disease, graft failure, 2.year overall survival of the patients after allogeneic stem cell transplantation depending on HLA matching of the unrelated donor / recipient pair.

  19. Major Histocompatibilty Complex-Restricted Adaptive Immune Responses to CT26 Colon Cancer Cell Line in Mixed Allogeneic Chimera.

    Science.gov (United States)

    Lee, K W; Choi, B; Kim, Y M; Cho, C W; Park, H; Moon, J I; Choi, G-S; Park, J B; Kim, S J

    2017-06-01

    Although the induction of mixed allogeneic chimera shows promising clinical tolerance results in organ transplantation, its clinical relevance as an anti-cancer therapy is yet unknown. We introduced a mixed allogenic chimera setting with the use of a murine colon cancer cell line, CT26, by performing double bone marrow transplantation. We analyzed donor- and recipient-restricted anti-cancer T-cell responses, and phenotypes of subpopulations of T cells. The protocol involves challenging 1 × 10 5 cells of CT26 cells intra-hepatically on day 50 after bone marrow transplantation, and, by use of CT26 lysates and an H-2L d -restricted AH1 pentamer, flow cytometric analysis was performed to detect the generation of cancer-specific CD4 + and CD8 + T cells at various time points. We found that immunocompetence against tumors depends heavily on cancer-specific CD8 + T-cell responses in a major histocompatibility complex-restricted manner; the evidence was further supported by the increase of interferon-γ-secreting CD4 + T cells. Moreover, we demonstrated that during the effector immune response to CT26 cancer challenge, there was a presence of central memory cells (CD62L hi CCR7 + ) as well as effector memory cells (CD62L lo CCR7 - ). Moreover, mixed allogeneic chimeras (BALB/c to C56BL/6 or vice versa) showed similar or heightened immune responses to CT26 cells compared with that of wild-type mice. Our results suggest that the responses of primary immunocompetency and of pre-existing memory T cells against allogeneic cancer are sustained and preserved long-term in a mixed allogeneic chimeric environment. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Unrelated allogeneic stem-cell transplantation in adult patients – 10-year experience

    Directory of Open Access Journals (Sweden)

    Jožef Pretnar

    2012-12-01

    Conclusion: Unrelated allogeneic stem-cell transplantation is suitable for acute myeloblastic leukemias with unfavorable risk factors. However, results in acute lymphoblastic leukemia are worse. Unrelated transplantation is not efficient as salvage treatment for patients with recurrent disease after autologous transplantation or chemotherapy- resistant relapse.

  1. Outcomes of allogeneic stem cell transplantation in patients with paroxysmal nocturnal hemoglobinuria with or without aplastic anemia.

    Science.gov (United States)

    Lee, Sung-Eun; Park, Sung Soo; Jeon, Young-Woo; Yoon, Jae-Ho; Cho, Byung-Sik; Eom, Ki-Sung; Kim, Yoo-Jin; Lee, Seok; Min, Chang-Ki; Kim, Hee-Je; Cho, Seok-Goo; Kim, Dong-Wook; Min, Woo-Sung; Lee, Jong Wook

    2017-10-01

    The aim of this study was to evaluate the long-term outcomes of allogeneic stem cell transplantation (SCT) in patients with paroxysmal nocturnal hemoglobinuria (PNH) with or without aplastic anemia (AA). A total of 33 patients with PNH clones who underwent allogeneic SCT were analyzed. After a median follow-up of 57 months (range, 6.0-151.3), the 5-year estimated overall survival rate was 87.9±5.7%. Four patients died of transplant-related mortality (TRM). With the exception of one patient with early TRM, 32 patients were engrafted. Two patients who had developed delayed GF received a second transplant and recovered. The cumulative incidences of acute graft-vs-host disease (GVHD) (≥grade II) and chronic GVHD (≥moderate) were 27.3±7.9% and 18.7±7.0%, respectively. Twenty-one patients receiving SCT with reduced-intensity conditioning (RIC) had available follow-up data for PNH cell population for the first 6 months post-transplant. Analysis of these data revealed that the PNH clones disappeared within approximately 2 months. RIC regimen was sufficient to eradicate PNH clones with sustained donor-type engraftment after allogeneic SCT. Therefore, application of allogeneic SCT with RIC should be considered in patients with PNH, in accordance with the severity of the underlying bone marrow failure. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Freeform lens design for LED collimating illumination.

    Science.gov (United States)

    Chen, Jin-Jia; Wang, Te-Yuan; Huang, Kuang-Lung; Liu, Te-Shu; Tsai, Ming-Da; Lin, Chin-Tang

    2012-05-07

    We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performance of the lens, a prototype of the collimator lens is also made, and an optical efficiency of 90.3% with a beam angle of 4.75 deg is measured.

  3. Central nervous system infection following allogeneic hematopoietic stem cell transplantation.

    Science.gov (United States)

    Hanajiri, Ryo; Kobayashi, Takeshi; Yoshioka, Kosuke; Watanabe, Daisuke; Watakabe, Kyoko; Murata, Yutaka; Hagino, Takeshi; Seno, Yasushi; Najima, Yuho; Igarashi, Aiko; Doki, Noriko; Kakihana, Kazuhiko; Sakamaki, Hisashi; Ohashi, Kazuteru

    2017-03-01

    Here, we described the clinical characteristics and outcomes of central nervous system (CNS) infections occurring after allogeneic hematopoietic stem cell transplantation (allo-HSCT) in a single institution over the previous 6 years. Charts of 353 consecutive allogeneic transplant recipients were retrospectively reviewed for CNS infection. A total of 17 cases of CNS infection were identified at a median of 38 days (range, 10-1028 days) after allo-HSCT. Causative pathogens were human herpesvirus-6 (n=6), enterococcus (n=2), staphylococcus (n=2), streptococcus (n=2), varicella zoster virus (n=1), cytomegalovirus (n=1), John Cunningham virus (n=1), adenovirus (n=1), and Toxoplasma gondii (n=1). The cumulative incidence of CNS infection was 4.1% at 1 year and 5.5% at 5 years. Multivariate analysis revealed that high-risk disease status was a risk factor for developing CNS infection (p=.02), and that overall survival at 3 years after allo-HSCT was 33% in patients with CNS infection and 53% in those without CNS infection (p=.04). Copyright © 2016 King Faisal Specialist Hospital & Research Centre. Published by Elsevier Ltd. All rights reserved.

  4. Gender-Dependent Survival of Allogeneic Trophoblast Stem Cells in Liver

    Science.gov (United States)

    Epple-Farmer, Jessica; Debeb, Bisrat G.; Smithies, Oliver; Binas, Bert

    2012-01-01

    In view of the well-known phenomenon of trophoblast immune privilege, trophoblast stem cells (TSCs) might be expected to be immune privileged, which could be of interest for cell or gene therapies. Yet in the ectopic sites tested so far, TSC transplants fail to show noticeable immune privilege and seem to lack physiological support. However, we show here that after portal venous injection, green fluorescent protein (GFP)-labeled TSCs survive for several months in the livers of allogeneic female but not male mice. Gonadectomy experiments revealed that this survival does not require the presence of ovarian hormones but does require the absence of testicular factors. By contrast, GFP-labeled allogeneic embryonic stem cells (ESCs) are reliably rejected; however, these same ESCs survive when mixed with unlabeled TSCs. The protective effect does not require immunological compatibility between ESCs and TSCs. Tumors were not observed in animals with either successfully engrafted TSCs or coinjected ESCs. We conclude that in a suitable hormonal context and location, ectopic TSCs can exhibit and confer immune privilege. These findings suggest applications in cell and gene therapy as well as a new model for studying trophoblast immunology and physiology. PMID:19523327

  5. The low-field permanent magnet electrostatic plasma lens

    International Nuclear Information System (INIS)

    Goncharov, A.; Gorshkov, V.; Maslov, V.; Zadorozhny, V.; Brown, I.

    2004-01-01

    We describe the status of ongoing research and development of the electrostatic plasma lens as used for the manipulation of high current broad beams of heavy ions of moderate energy. In some collaborative work at Lawrence Berkeley National Laboratory the lens was used to good effect for carrying out high dose ion implantation processing. In the process of this work a very narrow range of low magnetic field was found for which the ion-optical characteristics of the lens improved markedly. Subsequent theoretical analysis and computer modeling has led to an understanding of this phenomenon. These serendipitous results open up some attractive possibilities for the development of a new compact and low cost plasma lens based on permanent magnets rather than on current-driven field coils surrounding the lens volume. The development of this kind of lens, including both very low noise and minimal spherical aberration effects, may lead to a tool suitable for use in the injection beam lines of high current heavy ion linear accelerators. Here we briefly review the lens fundamentals, some characteristics of focusing heavy ion beams at low magnetic fields, and summarize recent theoretical and experimental developments, with emphasis on the relevance and suitability of the lens for accelerator injection application

  6. Precision lens assembly with alignment turning system

    Science.gov (United States)

    Ho, Cheng-Fang; Huang, Chien-Yao; Lin, Yi-Hao; Kuo, Hui-Jean; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Chen, Fong-Zhi

    2017-10-01

    The poker chip assembly with high precision lens barrels is widely applied to ultra-high performance optical system. ITRC applies the poker chip assembly technology to the high numerical aperture objective lenses and lithography projection lenses because of its high efficiency assembly process. In order to achieve high precision lens cell for poker chip assembly, an alignment turning system (ATS) is developed. The ATS includes measurement, alignment and turning modules. The measurement module is equipped with a non-contact displacement sensor (NCDS) and an autocollimator (ACM). The NCDS and ACM are used to measure centration errors of the top and the bottom surface of a lens respectively; then the amount of adjustment of displacement and tilt with respect to the rotational axis of the turning machine for the alignment module can be determined. After measurement, alignment and turning processes on the ATS, the centration error of a lens cell with 200 mm in diameter can be controlled within 10 arcsec. Furthermore, a poker chip assembly lens cell with three sub-cells is demonstrated, each sub-cells are measured and accomplished with alignment and turning processes. The lens assembly test for five times by each three technicians; the average transmission centration error of assembly lens is 12.45 arcsec. The results show that ATS can achieve high assembly efficiency for precision optical systems.

  7. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Yiping [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Bolton, Adam S.; Montero-Dorta, Antonio D.; Cornachione, Matthew A.; Zheng, Zheng; Brownstein, Joel R. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City, UT 84112 (United States); Mao, Shude [Physics Department and Tsinghua Centre for Astrophysics, Tsinghua University, Beijing 100084 (China); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Pérez-Fournon, Ismael; Marques-Chaves, Rui [Instituto de Astrofísica de Canarias, C/Vía Láctea, s/n, E-38205 San Cristóbal de La Laguna, Tenerife (Spain); Oguri, Masamune [Research Center for the Early Universe, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ménard, Brice, E-mail: yiping.shu@nao.cas.cn [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2016-12-20

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.

  8. Válvula de uretra anterior Anterior urethral valves

    Directory of Open Access Journals (Sweden)

    Silvio Tucci Jr.

    2003-02-01

    Full Text Available Objetivo: apresentar os aspectos clínicos, diagnósticos e terapêuticos de pacientes portadores de válvula da uretra anterior. Descrição: em dois neonatos, o diagnóstico presuntivo de patologia obstrutiva do trato urinário foi sugerido pela ultra-sonografia realizada no período pré-natal, confirmando-se o diagnóstico de válvula de uretra anterior pela avaliação pós-natal. Os pacientes foram submetidos a tratamento cirúrgico paliativo, com vesicostomia temporária e, posteriormente, definitivo, pela fulguração endoscópica das válvulas. Ambos evoluíram com função renal normal. Comentários: a válvula da uretra anterior é anomalia rara que deve ser considerada em meninos com quadro radiológico pré-natal sugestivo de obstrução infravesical, secundariamente à hipótese mais comum de válvula da uretra posterior. Ressaltamos a utilização da vesicostomia como derivação urinária temporária nestes casos, prevenindo potenciais complicações pela manipulação da uretra do recém-nascido.Objective: to discuss clinical signs, diagnostic tools and therapeutics of anterior urethral valves, an obstructive anomaly of the urinary system in males. Description: signs of urinary tract obstruction were identified on pre-natal ultrasound in two male fetuses and the diagnosis of anterior urethral valves was made through post-natal evaluation. As an initial treatment, vesicostomy was performed in both patients. Later, the valves were fulgurated using an endoscopic procedure. During the follow-up period both patients presented normal renal function. Comments: anterior urethral valves are a rare form of urethral anomaly that must be ruled out in boys with pre-natal ultrasound indicating infravesical obstruction. Vesicostomy used as an initial treatment rather than transurethral fulguration may prevent potential complications that can occur due to the small size of the neonatal urethra.

  9. Do autologous blood transfusion systems reduce allogeneic blood transfusion in total knee arthroplasty?

    Science.gov (United States)

    Pawaskar, Aditya; Salunke, Abhijeet Ashok; Kekatpure, Aashay; Chen, Yongsheng; Nambi, G I; Tan, Junhao; Sonawane, Dhiraj; Pathak, Subodhkumar

    2017-09-01

    To study whether autologus blood transfusion systems reduce the requirement of allogneic blood transfusion in patients undergoing total knee arthroplasty. A comprehensive search of the published literature with PubMed, Scopus and Science direct database was performed. The following search terms were used: (total knee replacement) OR (total knee arthroplasty) OR (TKA) AND (blood transfusion) OR (autologous transfusion) OR (autologous transfusion system). Using search syntax, a total of 748 search results were obtained (79 from PubMed, 586 from Science direct and 83 from Scopus). Twenty-one randomized control trials were included for this meta-analysis. The allogenic transfusion rate in autologus blood transfusion (study) group was significantly lower than the control group (28.4 and 53.5 %, respectively) (p value 0.0001, Relative risk: 0.5). The median units of allogenic blood transfused in study control group and control group were 0.1 (0.1-3.0) and 1.3 (0.3-2.6), respectively. The median hospital stay in study group was 9 (6.7-15.6) days and control group was 8.7 (6.6-16.7) days. The median cost incurred for blood transfusion per patient in study and control groups was 175 (85.7-260) and 254.7 (235-300) euros, respectively. This meta-analysis demonstrates that the use of auto-transfusion systems is a cost-effective method to reduce the need for and quantity of allogenic transfusion in elective total knee arthroplasty. Level I.

  10. TNFRSF14 aberrations in follicular lymphoma increase clinically significant allogeneic T-cell responses.

    Science.gov (United States)

    Kotsiou, Eleni; Okosun, Jessica; Besley, Caroline; Iqbal, Sameena; Matthews, Janet; Fitzgibbon, Jude; Gribben, John G; Davies, Jeffrey K

    2016-07-07

    Donor T-cell immune responses can eradicate lymphomas after allogeneic hematopoietic stem cell transplantation (AHSCT), but can also damage healthy tissues resulting in harmful graft-versus-host disease (GVHD). Next-generation sequencing has recently identified many new genetic lesions in follicular lymphoma (FL). One such gene, tumor necrosis factor receptor superfamily 14 (TNFRSF14), abnormal in 40% of FL patients, encodes the herpes virus entry mediator (HVEM) which limits T-cell activation via ligation of the B- and T-lymphocyte attenuator. As lymphoma B cells can act as antigen-presenting cells, we hypothesized that TNFRSF14 aberrations that reduce HVEM expression could alter the capacity of FL B cells to stimulate allogeneic T-cell responses and impact the outcome of AHSCT. In an in vitro model of alloreactivity, human lymphoma B cells with TNFRSF14 aberrations had reduced HVEM expression and greater alloantigen-presenting capacity than wild-type lymphoma B cells. The increased immune-stimulatory capacity of lymphoma B cells with TNFRSF14 aberrations had clinical relevance, associating with higher incidence of acute GVHD in patients undergoing AHSCT. FL patients with TNFRSF14 aberrations may benefit from more aggressive immunosuppression to reduce harmful GVHD after transplantation. Importantly, this study is the first to demonstrate the impact of an acquired genetic lesion on the capacity of tumor cells to stimulate allogeneic T-cell immune responses which may have wider consequences for adoptive immunotherapy strategies. © 2016 by The American Society of Hematology.

  11. Role of Aquaporin 0 in lens biomechanics.

    Science.gov (United States)

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  12. Perawatan Ortodontik Gigitan Terbuka Anterior

    Directory of Open Access Journals (Sweden)

    Yuniar Zen

    2014-06-01

    Full Text Available Perawatan gigitan terbuka anterior telah lama dianggap sebagai tantangan bagi ortodontis. Prevalensi gigitan terbuka anterior antara 3,5% hingga 11% terdapat pada berbagai usia dan kelompok etnis, serta ada sekitar 17% pasien ortodonti memiliki gigitan terbuka. Stabilitas hasil perawatan gigitan terbuka anterior sangat sulit, karena adanya kombinasi diskrepansi anteroposterior dengan gigitan terbuka skeletal sehingga dibutuhkan tingkat keterampilan diagnosis dan klinis yang tinggi. Etiologi gigitan terbuka anterior sangat kompleks karena dapat melibatkan skeletal, dental, dan faktor-faktor habitual. Eliminasi faktor etiologi merupakan hal yang penting dalam perawatan gigitan terbuka anterior. Berbagai cara perawatan untuk koreksi gigitan terbuka anterior diantaranya bedah ortognatik dan perawatan ortodontik kamuflase, seperti high-pull headgear, chincup, bite blocks, alatfungsional, pencabutan gigi, multi-loop edgewise archwires dan mini implan. Stabilitas hasil perawatan adalah kriteria yang paling penting dalam menentukan cara perawatan gigitan terbuka anterior. Orthodontic Treatment of Anterior Open Bite. An anterior open bite therapy has long been considered a challenge to orthodontist. The prevalence of anterior openbite range from 3,5 % to 11% among various age and ethnic groups and it has been shown that approximately 17% of orthodontic patients have open bite. Stability of treatment result of anterior open bite with well-maintained results is difficult, because the combination of anteroposteriorly discrepancy with skeletal open bite requires the highest degree of diagnostic and clinical skill. The etiology is complex, potentially involving skeletal, dental and habitual factors. The importance of an anterior open bite therapy is to eliminate the cause of the open bite. Various treatment modalities for the correction of an anterior open bite have been proposed, orthognatic surgery and orthodontic camouflage treatment such as high

  13. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was

  14. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Science.gov (United States)

    Wang, Zhonghao; Liang, Xuanwei; Wu, Ziqiang; Lin, Jialiu; Huang, Jingjing

    2015-01-01

    To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility. Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC). All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (pPhotoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  15. Retrospective Study of Vitreous Tap Technique Using Needle Aspiration for Management of Shallow Anterior Chamber during Phacoemulsification

    Directory of Open Access Journals (Sweden)

    Ashraf Ahmed Nossair

    2017-01-01

    Full Text Available Purpose. To evaluate the technique of vitreous tap using needle aspiration for management of anterior chamber shallowness during phacoemulsification. Methods. A retrospective study included 26 eyes of 17 patients who underwent phacoemulsification in which vitreous tap was performed using a 27-gauge needle attached to a 5 ml syringe, inserted 3.5 mm from the limbus to aspirate 0.2 ml of liquefied vitreous if a cohesive (OVD failed to sufficiently deepen the anterior chamber. Results. Preoperative anterior chamber depth was 2.31 ± 0.26 mm, axial length was 21.7 ± 0.67 mm, lens thickness was 4.5 ± .19 mm, and cataract grade was 3.77 ± 1.4. Preoperative CDVA in LogMAR units was 0.98 ± 0.75. Coexisting angle closure glaucoma was present in 7 patients (26.92% preoperatively. Vitreous needle tap was successful in vitreous removal on the first attempt in 26 eyes (100%. Postoperative follow-up period was 22.88 ± 10.24 (4–39 months. The final postoperative CDVA in LogMAR units was 0.07 ± 0.1, while the final postoperative IOP was 16.54 ± 1.45 mmHg. No complications related to vitreous tap were noted. Conclusion. Vitreous needle tap is a simple, cost-effective, and safe technique for management of shallow anterior chamber in phacoemulsification.

  16. Chapter 03: Correct use of a hand lens

    Science.gov (United States)

    Alex Wiedenhoeft

    2011-01-01

    A hand lens is a powerful tool for the identification of wood, but like all tools it must be used correctly to take full advantage of its powers. The hand lens has two main parts, a lens that magnifies the object of interest (generally we use 10X or 14X lenses in wood identification; a 14X lens is recommended for use with this manual) and a housing to hold and protect...

  17. The neutron silicon lens. An update of the thermal neutron lens results

    International Nuclear Information System (INIS)

    Johnson, M.W.; Daymond, M.R.

    2001-01-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  18. The neutron silicon lens. An update of the thermal neutron lens results

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, M.W.; Daymond, M.R. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire (United Kingdom)

    2001-03-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  19. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    Science.gov (United States)

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Socially disadvantaged parents of children treated with allogeneic haematopoietic stem cell transplantation (HSCT)

    DEFF Research Database (Denmark)

    Larsen, Hanne Bækgaard; Heilmann, Carsten; Johansen, Christoffer

    2013-01-01

    PURPOSE: This study was undertaken to test a daily Family Navigator Nurse (FNN) conducted intervention program, to support parents during the distressful experience of their child's Allogeneic Haematopoietic Stem Cell Transplantation (HSCT). METHODS: A qualitative analysis of the supportive...

  1. GMP-compliant, large-scale expanded allogeneic natural killer cells have potent cytolytic activity against cancer cells in vitro and in vivo.

    Directory of Open Access Journals (Sweden)

    Okjae Lim

    Full Text Available Ex vivo-expanded, allogeneic natural killer (NK cells can be used for the treatment of various types of cancer. In allogeneic NK cell therapy, NK cells from healthy donors must be expanded in order to obtain a sufficient number of highly purified, activated NK cells. In the present study, we established a simplified and efficient method for the large-scale expansion and activation of NK cells from healthy donors under good manufacturing practice (GMP conditions. After a single step of magnetic depletion of CD3(+ T cells, the depleted peripheral blood mononuclear cells (PBMCs were stimulated and expanded with irradiated autologous PBMCs in the presence of OKT3 and IL-2 for 14 days, resulting in a highly pure population of CD3(-CD16(+CD56(+ NK cells which is desired for allogeneic purpose. Compared with freshly isolated NK cells, these expanded NK cells showed robust cytokine production and potent cytolytic activity against various cancer cell lines. Of note, expanded NK cells selectively killed cancer cells without demonstrating cytotoxicity against allogeneic non-tumor cells in coculture assays. The anti-tumor activity of expanded human NK cells was examined in SCID mice injected with human lymphoma cells. In this model, expanded NK cells efficiently controlled lymphoma progression. In conclusion, allogeneic NK cells were efficiently expanded in a GMP-compliant facility and demonstrated potent anti-tumor activity both in vitro and in vivo.

  2. Different effects of lansoprazole and rabeprazole on the plasma voriconazole trough levels in allogeneic hematopoietic cell transplant recipients.

    Science.gov (United States)

    Yasu, Takeo; Konuma, Takaaki; Kato, Seiko; Kurokawa, Yosuke; Takahashi, Satoshi; Tojo, Arinobu

    2016-10-01

    Voriconazole (VRC) is widely used as prophylaxis and in the treatment of invasive fungal disease (IFD) after allogeneic hematopoietic cell transplantation (HCT). We retrospectively examined the results of VRC therapeutic drug monitoring (TDM) in allogeneic HCT recipients. A total of 474 samples were obtained from 59 adult patients who received VRC during the first 100 days following HCT between 2009 and 2014 in our institute. Seventeen patients received VRC for prophylaxis of IFD, and 42 received VRC for the empirical or preemptive therapy for IFD. A total of 299 samples (63 %) were obtained during the administration of the intravenous form of VRC. The median VRC daily dose based on the actual body weight was 6.68 mg/kg/day (range, 1.92-10.41 mg/kg/day). The median VRC trough level was 0.99 mg/l (range, lansoprazole as compared to rabeprazole (P lansoprazole and rabeprazole have different effects on the plasma VRC trough levels in the allogeneic HCT recipients.

  3. Complications of allogeneic hematopoietic stem cell transplantation.

    Science.gov (United States)

    Arnaout, Karim; Patel, Nihar; Jain, Maneesh; El-Amm, Joelle; Amro, Farah; Tabbara, Imad A

    2014-08-01

    Infection, graft-versus-host disease (GVHD), and to a lesser extent sinusoidal obstructive syndrome (SOS) represent the major causes of morbidity and mortality in patients undergoing allogeneic hematopoietic stem cell transplantation (AHSCT). During the last decade, progress in prevention and treatment of these complications led to improvement in the outcome of these patients. Despite the fact that nonmyeloablative regimens have been increasingly used in elderly patients and in patients with co-morbidities, the nonrelapse related mortality remains a challenge and long-term follow-up is required. The objective of this manuscript is to provide an updated concise review of the complications of AHSCT and of the available treatment interventions.

  4. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  5. Gastrointestinal toxicity, systemic inflammation, and liver biochemistry in allogeneic hematopoietic stem cell transplantation

    DEFF Research Database (Denmark)

    Jordan, Karina; Pontoppidan, Peter; Uhlving, Hilde Hylland

    2017-01-01

    Liver toxicity is frequently seen in relation to allogeneic hematopoietic stem cell transplantation (HSCT), but pathogenesis and the risk factors are poorly understood. The purpose of this study was to investigate associations between liver toxicity, gastrointestinal toxicity, and levels of immun...

  6. Method for producing an isoplanatic aspheric monofocal intraocular lens, and resul ting lens

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    [EN] The invention can be used to obtain isoplanatic aspheric mono focal intraocular lenses in a viewing range of up to 25° (preferably up to 10°). The method comprises the following steps: l. mathematical defmition of an aphakic eye model; 2. mathematical definition of an intraocular lens model; 3. mathematical defmition of the implantation of the lens; 4. mathematical defmition of the merit function; 5. definition of the contour conditions; 6. defmition of a measurement for charact...

  7. Allogeneic stem cell transplantation for acute myeloid leukemia with del(7q) following untreated chronic lymphocytic leukemia.

    Science.gov (United States)

    DeFilipp, Zachariah; Huynh, Donny V; Fazal, Salman; Sahovic, Entezam

    2012-01-01

    The development of hematologic malignancy in the presence of chronic lymphocytic leukemia (CLL) is rare. We present a case of acute myeloid leukemia (AML) with del(7q) occurring in a patient with a 4-year history of untreated CLL. Application of flow cytometry and immunohistochemistry allowed for characterization of two distinct coexisting malignant cell populations. After undergoing induction and consolidation chemotherapy, the patient achieved complete remission of AML with the persistence of CLL. Allogeneic transplantation was pursued given his unfavorable cytogenetics. Subsequent matched unrelated donor allogeneic stem cell transplantation resulted in full engraftment and complete remission, with no evidence of AML or CLL. Due to a scarcity of reported cases, insight into treatment and prognosis in cases of concurrent AML and CLL is limited. However, prognosis seems dependent on the chemosensitivity of AML. CLL did not have a detrimental effect on treatment or transplant outcome in our case. This is the first reported case of concomitant de novo AML and CLL to undergo allogeneic transplantation. The patient remained in complete hematologic and cytogenetic remission of both malignancies over a year after transplantation.

  8. Perioperative Allogeneic Red Blood-Cell Transfusion Associated with Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Everhart, Joshua S; Sojka, John H; Mayerson, Joel L; Glassman, Andrew H; Scharschmidt, Thomas J

    2018-02-21

    Perioperative allogeneic red blood-cell transfusion is a suspected risk factor for surgical site infection (SSI) after total joint arthroplasty (TJA), but the interrelationships among SSI risk, transfusion dose, preoperative anemia, and the presence of coagulopathies have not been well described. Data on SSI within 1 year after surgery as well as on transfusion with blood products within 30 days after surgery were obtained for 6,788 patients who had undergone primary or revision total hip or knee arthroplasty from 2000 to 2011 in a single hospital system. Multivariate logistic regression modeling was used to determine the independent association between allogeneic red blood-cell transfusion and SSI. There was a dose-dependent association between allogeneic red blood-cell transfusion and SSI, with the infection rate increasing as the transfusion dose increased from 1 unit (odds ratio [OR] = 1.97; 95% confidence interval [CI] = 1.38, 2.79; p 3 units (OR = 7.40; CI = 4.91, 11.03; p conservation strategies. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  9. Analysis of the width ratio and wear rate of maxillary anterior teeth in the Korean population.

    Science.gov (United States)

    Oh, Yeon-Ah; Yang, Hong-So; Park, Sang-Won; Lim, Hyun-Pil; Yun, Kwi-Dug; Park, Chan

    2017-04-01

    The purpose of this study was to compare the width ratio of maxillary anterior teeth according to age in the Korean population and to evaluate the maxillary central incisor width-to-length (W/L) ratio, given differences in age and gender. Ninety-three Korean adults were divided into 3 groups (n = 31) by age. Group I was 20 - 39 years old, Group II was 40 - 59 years old, and Group III was over 60 years of age. After taking an impression and a cast model of the maxillary arch, the anterior teeth width ratio and central incisor W/L ratio were calculated from standard digital images of the cast models using a graph paper with a digital single lens reflex (DSLR) camera. The calculated ratios were compared among all groups and central incisor W/L ratio were analyzed according to age and gender. All comparative data were statistically analyzed with one-sample t-tests, one-way ANOVAs with Tukey tests, and independent t-tests. No significant differences in maxillary anterior teeth ratios were found among the age groups. The maxillary central incisor W/L ratios in Group III were the greatest and were significantly higher than those in the other groups. The central incisor W/L ratio of men was higher than that of women in Group II. Maxillary anterior teeth width ratios were similar in all age groups in the Korean population. The maxillary central incisor was observed as worn teeth in the group over 60 years of age, and a significant difference between genders was found in 40 to 50 year olds.

  10. Effects of T cell depletion in radiation bone marrow chimeras. II. Requirement for allogeneic T cells in the reconstituting bone marrow inoculum for subsequent resistance to breaking of tolerance

    International Nuclear Information System (INIS)

    Sykes, M.; Sheard, M.A.; Sachs, D.H.

    1988-01-01

    The ability of normal recipient-type lymphocytes to break tolerance in long-term allogenic radiation chimeras has been investigated. Reconstitution of lethally irradiated mice with a mixture of syngeneic and allogeneic T cell-depleted (TCD) bone marrow (BM) has previously been shown to lead to mixed chimerism and permanent, specific tolerance to donor and host alloantigen (3-5). If allogeneic T cells are not depleted from the reconstituting inoculum, complete allogeneic chimerism results; however, no clinical evidence for GVHD is observed, presumably due to the protective effect provided by syngeneic TCD BM. This model has now been used to study the effects of allogenic T cells administered in reconstituting BM inocula on stability of long-term tolerance. We have attempted to break tolerance in long-term chimeras originally reconstituted with TCD or non-TCD BM by challenging them with inocula containing normal, nontolerant recipient strain lymphocytes. tolerance was broken with remarkable ease in recipients of mixed marrow inocula in which both original BM components were TCD. In contrast, tolerance in chimeras originally reconstituted with non-TCD allogeneic BM was not affected by such inocula. Susceptibility to loss of chimerism and tolerance was not related to initial levels of chimerism per se, but rather to T cell depletion of allogeneic BM, since chimeras reconstituted with TCD allogeneic BM alone (mean level of allogeneic chimerism 98%) were as susceptible as mixed chimeras to the tolerance-breaking effects of such inocula. The possible contribution of GVH reactivity to this resistance was investigated using an F1 into parent strain combination. In these animals, the use of non-TCD F1 BM inocula for reconstitution did not lead to resistance to the tolerance-breaking effects of recipient strain splenocytes

  11. Nanoparticle delivery of donor antigens for transplant tolerance in allogeneic islet transplantation.

    Science.gov (United States)

    Bryant, Jane; Hlavaty, Kelan A; Zhang, Xiaomin; Yap, Woon-Teck; Zhang, Lei; Shea, Lonnie D; Luo, Xunrong

    2014-10-01

    Human islet cell transplantation is a promising treatment for type 1 diabetes; however, long-term donor-specific tolerance to islet allografts remains a clinically unmet goal. We have previously shown that recipient infusions of apoptotic donor splenocytes chemically treated with 1-ethyl-3-(3'-dimethylaminopropyl)-carbodiimide (donor ECDI-SP) can mediate long-term acceptance of full major histocompatibility complex (MHC)-mismatched murine islet allografts without the use of immunosuppression. In this report, we investigated the use of poly(lactide-co-glycolide) (PLG) particles in lieu of donor ECDI-SP as a synthetic, cell-free carrier for delivery of donor antigens for the induction of transplant tolerance in full MHC-mismatched murine allogeneic islet transplantation. Infusions of donor antigen-coupled PLG particles (PLG-dAg) mediated tolerance in ∼20% of recipient mice, and the distribution of cellular uptake of PLG-dAg within the spleen was similar to that of donor ECDI-SP. PLG-dAg mediated the contraction of indirectly activated T cells but did not modulate the direct pathway of allorecognition. Combination of PLG-dAg with a short course of low dose immunosuppressant rapamycin at the time of transplant significantly improved the tolerance efficacy to ∼60%. Furthermore, altering the timing of PLG-dAg administration to a schedule that is more feasible for clinical transplantation resulted in equal tolerance efficacy. Thus, the combination therapy of PLG-dAg infusions with peritransplant rapamycin represents a clinically attractive, biomaterials-based and cell-free method for inducing long-term donor-specific tolerance for allogeneic cell transplantation, such as for allogeneic islet transplantation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Multipoint photonic doppler velocimetry using optical lens elements

    Science.gov (United States)

    Frogget, Brent Copely; Romero, Vincent Todd

    2014-04-29

    A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

  13. Lichen striatus occurring after allogenic peripheral blood stem cell transplantation in an adult with aplastic anemia.

    Science.gov (United States)

    Mun, Je-Ho; Park, Hyun-Je; Kim, Hoon-Soo; Kim, Su-Han; Ko, Hyun-Chang; Kim, Byung-Soo; Kim, Moon-Bum

    2012-02-01

    Lichens striatus (LS) is an acquired, self-limiting inflammatory dermatosis that follows the lines of Blaschko. The etiology of the eruption is unknown, but several theories have been proposed with focus on environmental factors, viral infection, cutaneous injury, hypersensitivity, and genetic predisposition. We describe a 19-year-old woman who developed a unilateral linear eruption 17 months after allogenic peripheral blood stem cell transplantation. Histopathology revealed features, which were consistent with LS. To the best of our knowledge, our patient is the first case describing the appearance of LS occurring after allogenic stem cell transplantation. We speculate that this condition represents an unusual form of localized, chronic graft-versus-host disease.

  14. Disassembly of the lens fiber cell nucleus to create a clear lens: the p27 descent

    Science.gov (United States)

    The eye lens is unique among tissues: it is transparent, does not form tumors, and the majority of its cells degrade their organelles, including their cell nuclei. A mystery for over a century, there has been considerable recent progress in elucidating mechanisms of lens fiber cell denucleation (LFC...

  15. The sloan lens acs survey. II. Stellar populations and internal structure of early-type lens galaxies

    NARCIS (Netherlands)

    Treu, Tommaso; Koopmans, Léon V.; Bolton, Adam S.; Burles, Scott; Moustakas, Leonidas A.

    2006-01-01

    We use HST images to derive effective radii and effective surface brightnesses of 15 early-type (E+S0) lens galaxies identified by the SLACS Survey. Our measurements are combined with stellar velocity dispersions from the SDSS database to investigate for the first time the distribution of lens

  16. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  17. Establishment of a murine graft-versus-myeloma model using allogeneic stem cell transplantation.

    Directory of Open Access Journals (Sweden)

    Marilène Binsfeld

    Full Text Available Multiple myeloma (MM is a malignant plasma cell disorder with poor long-term survival and high recurrence rates. Despite evidence of graft-versus-myeloma (GvM effects, the use of allogeneic hematopoietic stem cell transplantation (allo-SCT remains controversial in MM. In the current study, we investigated the anti-myeloma effects of allo-SCT from B10.D2 mice into MHC-matched myeloma-bearing Balb/cJ mice, with concomitant development of chronic graft-versus-host disease (GvHD.Balb/cJ mice were injected intravenously with luciferase-transfected MOPC315.BM cells, and received an allogeneic (B10.D2 donor or autologous (Balb/cJ donor transplant 30 days later. We observed a GvM effect in 94% of the allogeneic transplanted mice, as the luciferase signal completely disappeared after transplantation, whereas all the autologous transplanted mice showed myeloma progression. Lower serum paraprotein levels and lower myeloma infiltration in bone marrow and spleen in the allogeneic setting confirmed the observed GvM effect. In addition, the treated mice also displayed chronic GvHD symptoms. In vivo and in vitro data suggested the involvement of effector memory CD4 and CD8 T cells associated with the GvM response. The essential role of CD8 T cells was demonstrated in vivo where CD8 T-cell depletion of the graft resulted in reduced GvM effects. Finally, TCR Vβ spectratyping analysis identified Vβ families within CD4 and CD8 T cells, which were associated with both GvM effects and GvHD, whereas other Vβ families within CD4 T cells were associated exclusively with either GvM or GvHD responses.We successfully established an immunocompetent murine model of graft-versus-myeloma. This is the first murine GvM model using immunocompetent mice that develop MM which closely resembles human MM disease and that are treated after disease establishment with an allo-SCT. Importantly, using TCR Vβ spectratyping, we also demonstrated the presence of GvM unique responses

  18. Perubahan Sosial Berbasis Tasawuf: Studi Kasus Fethullah Gülen Dan Gülen Movement

    Directory of Open Access Journals (Sweden)

    Sulaiman Sulaiman

    2016-06-01

    Full Text Available Abstract: This article aims at analyzing Fethullah Gülen and the Gülen Movement which have succeeded in performing social change based on the teaching of Sufism. He did Sufism creativity in order that Sufism teaching was able to respond the changes that occur in the modernlife. He believed that, only by reinterpretation and contextualization of Sufism, the spiritual dimension of Islam would be able to perform the transformation or social change among the Muslims. Therefore, by using Max Weber’s theory of social action, this paper will analyze three key teachings of Sufism of Gülen: ascetic (zuhd, inbisat (expansion, and hizmet. Based on the Weber's theory, Gülen occupied a very central and authoritative position: agent/actor, action and meaning. As a source of meaning and interpreter of meaning, the key concepts of Sufism were transformed by Gülen to the internal and external communities so that they had made a move to do social movements and humanity. For the followers of Gülen, the movement was called the Gülen Movement or the Hizmet Movement which was engaged in the fields of education, health care, humanitarian assistance, and the mass media. All forms of movement were entirely based on the spiritual values of Islam that had been formulated by Gülen. الملخص: يهدف هذا البحث إلى تحليل شخصية فتح الله غولن وحركته الذي تمكن من القيام بالتغيير الاجتماعي على أساس التعاليم الصوفية. إن فتح الله غولن قام بإحياء التصوف في صورته الجدّية والحيوية في حياة الإنسان المعاصر. ويعتقد أن إعادة التفسير لتعاليم التصوف مع مراعاة الواقع قادرة على التغيير الاجتماعي بين المسلمين. من أجل ذلك، أن استخدام نظرية ويبر، يمكن تحليل تعاليم التصوف الثلاثة

  19. Characteristics of soft X-ray lens

    International Nuclear Information System (INIS)

    Qin Yi

    2007-12-01

    A soft X-lens was devised with waveguide X-ray optics of total external reflection (TER). The lens consists of a stack of 1 387 TER waveguides with inner diameter of 0.45 mm and outer diameter of 0.60 mm. With the help of plasma sources of soft X-ray radiation, high density of pure soft X-ray radiation (without plasma expansion fragments) with broad-band spectral range can be obtained at the focus of the lens. As laser-plasma is considered, the radiation density of 1.3 x 10 5 W/cm 2 is obtained, the transmission coefficient is 18.6%, the ratio of the density at the focus with and without the lens is 1000 and the radiation capture is 28.9 degree. The density of 0.5 TW/cm 2 can be obtained as far as Qiang-Guang I facility is considered. (authors)

  20. Development of an accommodating intra-ocular lens - In vitro prevention of re-growth of pig and rabbit lens capsule epithelial cells

    NARCIS (Netherlands)

    van Kooten, Theo G.; Koopmans, Steven; Terwee, Thom; Norrby, Sverker; Hooymans, J. M. M.; Busscher, Henk J.

    2006-01-01

    Cataract surgery is routinely performed to replace the clouded lens by a rigid polymeric intra-ocular lens unable to accommodate. By implanting a silicone gel into an intact capsular bag the accommodating properties of the natural lens can be maintained or enhanced. The implantation success of

  1. Effects of x-irradiation on lens reducing systems

    International Nuclear Information System (INIS)

    Giblin, F.J.; Chakrapani, B.; Reddy, V.N.

    1978-01-01

    Studies have been made of the effects of x ray on various lens reducing systems including the levels of NADPH and glutathione (GSH), the activity of the hexose monophosphate shunt (HMS), and the activities of certain enzymes including glutathion reductase, glutathione peroxidase, and glucose-6-phosphate dehydrogenase (G-6-PD). It was found that during several weeks following x irradiation but prior to cataract formation there was very little change in the number of reduced -SH groups per unit weight of lens protein but that, with the appearance of cataract, there was a sudden loss of protein -SH groups. In contrast, the concentration of GSH in the x-rayed lens decreased throughout the experimental period. Similarly, the concentration of NADPH in the x-rayed lens was found to decrease significantly relative to controls one week prior to cataract formation and the ratio of NADPH to NADP + in the lens shifted at this time period from a value greater than 1.0 in the control lens to less than 1.0 in the x-rayed lens. A corresponding decrease occurred in the activity of the HMS in x-rayed lenses as measured by culture in the presence of 1- 14 C-labelled glucose. G-6-PD was partially inactivated in the x-rayed lens. Of the eight enzymes studied, G-6-PD appeared to be the most sensitive to x-irradiation. The data indicate that x-irradiation results in a steady decrease in the effectiveness of lens reducing systems and that, when these systems reach a critically low point, sudden oxidation of protein -SH groups and formation of high molecular weight protein aggregates may be initiated

  2. Gastrointestinal toxicity, systemic inflammation, and liver biochemistry in allogeneic hematopoietic stem cell transplantation

    Science.gov (United States)

    Liver toxicity is frequently seen in relation to allogeneic hematopoietic stem cell transplantation (HSCT), but pathogenesis and the risk factors are poorly understood. The purpose of this study was to investigate associations between liver toxicity, gastrointestinal toxicity, and levels of immune-r...

  3. Photon nanojet lens: design, fabrication and characterization

    International Nuclear Information System (INIS)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Chen, Yifang; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin

    2016-01-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect. (paper)

  4. Protein synthesis in x-irradiated rabbit lens

    International Nuclear Information System (INIS)

    Garadi, R.; Foltyn, A.R.; Giblin, F.J.; Reddy, V.N.

    1984-01-01

    The present study deals with the incorporation of 35 S methionine into lens crystallins as a function of time after x-irradiation. Crystallin synthesis is first affected approximately 4 weeks following x-irradiation. This coincides with the time period at which the ratio of the two cations in the lens is affected, as shown in earlier studies. A greater decrease in 35 S-methionine incorporation into crystallins is observed between 5-7 weeks following x-irradiation in good agreement with a cation imbalance at these time intervals. These studies also revealed for the first time that the change in cation distribution can affect not only crystallin synthesis, but also the synthesis of certain polypeptides of lens membranes. No alteration in protein synthesis could be detected in lens epithelium even after 7 weeks following irradiation. In addition to the effect of Na+ and K+ levels on protein synthesis, an impaired transport of amino acids into the x-rayed lens was also found to be a factor in the observed reduction in synthesis of the crystallin, cytoskeletal and membrane proteins of the fiber cells. It is concluded that Na+/K+ ratio as well as the availability of amino acids in the lens are important factors in protein synthesis of x-ray cataracts

  5. Histomorhological and clinical evaluation of maxillary alveolar ridge reconstruction after craniofacial trauma by applying combination of allogeneic and autogenous bone graft

    Directory of Open Access Journals (Sweden)

    Francesco Saverio De Ponte

    2017-02-01

    Full Text Available A variety of techniques and materials for the rehabilitation and reconstruction of traumatized maxillary ridges prior to dental implants placement have been described in literature. Autogenous bone grafting is considered ideal by many researchers and it still remains the most predictable and documented method. The aim of this report is to underline the effectiveness of using allogeneic bone graft for managing maxillofacial trauma. A case of a 30-year-old male with severely atrophic maxillary ridge as a consequence of complex craniofacial injury is presented here. Augmentation procedure in two stages was performed using allogeneic and autogenous bone grafts in different areas of the osseous defect. Four months after grafting, during the implants placement surgery, samples of both sectors were withdrawn and submitted to histological evaluation. On the examination of the specimens, treated by hematoxylin and eosin staining, the morphology of integrated allogeneic bone grafts was revealed to be similar to the autologous bone. Our clinical experience shows how the allogeneic bone graft presented normal bone tissue architecture and is highly vascularized, and it can be used for reconstruction of severe trauma of the maxilla.

  6. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  7. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame. (a) Identification. An opthalmic trial lens frame is a mechanical device intended to hold trial lenses for vision...

  8. An adjustable electron achromat for cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M., E-mail: rtromp@us.ibm.com [IBM T.J. Watson Research Center, 1101 Kitchawan Road, Yorktown Heights, NY 10598 (United States); Leiden Institute of Physics, Kamerlingh Onnes Laboratory, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-12-15

    Chromatic aberration correction in light optics began with the invention of a two-color-corrected achromatic crown/flint lens doublet by Chester Moore Hall in 1730. Such color correction is necessary because any single glass shows dispersion (i.e. its index of refraction changes with wavelength), which can be counteracted by combining different glasses with different dispersions. In cathode lens microscopes (such as Photo Electron Emission Microscopy – PEEM) we encounter a similar situation, where the chromatic aberration coefficient of the cathode lens shows strong dispersion, i.e. depends (non-linearly) on the energy with which the electrons leave the sample. Here I show how a cathode lens in combination with an electron mirror can be configured as an adjustable electron achromat. The lens/mirror combination can be corrected at two electron energies by balancing the settings of the electron mirror against the settings of the cathode lens. The achromat can be adjusted to deliver optimum performance, depending on the requirements of a specific experiment. Going beyond the achromat, an apochromat would improve resolution and transmission by a very significant margin. I discuss the requirements and outlook for such a system, which for now remains a wish waiting for fulfilment. - Highlights: • The properties of cathode objective lens plus electron mirror are discussed. • In analogy with light-optical achromats, cathode lens plus mirror can be configured as an electron achromat. • Unlike light optics, the electron achromat can be adjusted to best fulfill experimental requirements.

  9. АВ0-INCOMPATIBILITY IN ALLOGENEIC HEMATOPOIETIC STEM CELL TRANSPLANTATION: 15-YEARS EXPERIENCE OF R.M. GORBACHEVA MEMORIAL RESEARCH INSTITUTE FOR CHILDREN ONCOLOGY, HEMATOLOGY AND TRANSPLANTATION

    Directory of Open Access Journals (Sweden)

    M. A. Kucher

    2016-01-01

    Full Text Available Introduction. AB0-incompatibility in different types of allogeneic hematopoietic stem cell transplantation (HSCT may be an additional aggravating factor for the development of immunological complications and decrease treatment efficacy.Materials and methods. From May 1999 to December 2015 in R.M. Gorbacheva Memorial Research Institute for Children Oncology, Hematology and Transplantation 1131 patients with malignancies and hereditary diseases were included to the study, which were performed 1428 allogeneic HSCT: allogeneic unrelated – 814 (57.0 %, allogeneic related – 344 (24.1 %, haploidentical – 267 (18.7 %, umbilical cord blood in 3 patients (0.2 %. Age was 0–76 years, median – 25 years.Results. In 54.6 % of cases (n = 780 АВ0-incompatibility was determined: major – 37.8 % (n = 295; minor – 45.4 % (n = 354; combined – 16.8 % (n = 131. АВ0-incompatibility in allogeneic HSCT did not influence overall survival (p = 0.56, frequency of acute graftversus-host disease (GVHD (p = 0.2. There was an increased frequency of acute GVHD in combination with reduced intensity conditioning regimens and АВ0-incompatibility (30.8 % compared with myeloablative regimens (15.3 %; p = 0.002.Conclusion. The presence of АВ0-incompatibility is not a limiting factor to perform allogeneic HSCT, however, it demands high quality prophylaxis and sophisticated transfusion therapy to prevent immune complications.

  10. Anterior segment parameters as predictors of intraocular pressure reduction after phacoemulsification in eyes with open-angle glaucoma.

    Science.gov (United States)

    Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C

    2017-07-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2  = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2  = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2  = 0.52), and lens vault (β = -0.002, P = .009, R 2  = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Fermat's least-time principle and the embedded transparent lens

    Science.gov (United States)

    Kantowski, R.; Chen, B.; Dai, X.

    2013-10-01

    We present a simplified version of the lowest-order embedded point mass gravitational lens theory and then make the extension of this theory to any embedded transparent lens. Embedding a lens effectively reduces the gravitational potential’s range, i.e., partially shields the lensing potential because the lens mass is made a contributor to the mean mass density of the Universe and not simply superimposed upon it. We give the time-delay function for the embedded point mass lens from which we can derive the simplified lens equation by applying Fermat’s least-time principle. Even though rigorous derivations are only made for the point mass in a flat background, the generalization of the lens equation to lowest order for any distributed lens in any homogeneous background is obvious. We find from this simplified theory that embedding can introduce corrections above the few percent level in weak lensing shears caused by large clusters but only at large impacts. The potential part of the time delay is also affected in strong lensing at the few percent level. Additionally we again confirm that the presence of a cosmological constant alters the gravitational deflection of passing photons.

  12. Allogeneic Umbilical Cord-Derived Mesenchymal Stem Cells as a Potential Source for Cartilage and Bone Regeneration: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    A. Marmotti

    2017-01-01

    Full Text Available Umbilical cord (UC may represent an attractive cell source for allogeneic mesenchymal stem cell (MSC therapy. The aim of this in vitro study is to investigate the chondrogenic and osteogenic potential of UC-MSCs grown onto tridimensional scaffolds, to identify a possible clinical relevance for an allogeneic use in cartilage and bone reconstructive surgery. Chondrogenic differentiation on scaffolds was confirmed at 4 weeks by the expression of sox-9 and type II collagen; low oxygen tension improved the expression of these chondrogenic markers. A similar trend was observed in pellet culture in terms of matrix (proteoglycan production. Osteogenic differentiation on bone-graft-substitute was also confirmed after 30 days of culture by the expression of osteocalcin and RunX-2. Cells grown in the hypertrophic medium showed at 5 weeks safranin o-positive stain and an increased CbFa1 expression, confirming the ability of these cells to undergo hypertrophy. These results suggest that the UC-MSCs isolated from minced umbilical cords may represent a valuable allogeneic cell population, which might have a potential for orthopaedic tissue engineering such as the on-demand cell delivery using chondrogenic, osteogenic, and endochondral scaffold. This study may have a clinical relevance as a future hypothetical option for allogeneic single-stage cartilage repair and bone regeneration.

  13. Lens regeneration in axolotl: new evidence of developmental plasticity

    Directory of Open Access Journals (Sweden)

    Suetsugu-Maki Rinako

    2012-12-01

    Full Text Available Abstract Background Among vertebrates lens regeneration is most pronounced in newts, which have the ability to regenerate the entire lens throughout their lives. Regeneration occurs from the dorsal iris by transdifferentiation of the pigment epithelial cells. Interestingly, the ventral iris never contributes to regeneration. Frogs have limited lens regeneration capacity elicited from the cornea during pre-metamorphic stages. The axolotl is another salamander which, like the newt, regenerates its limbs or its tail with the spinal cord, but up until now all reports have shown that it does not regenerate the lens. Results Here we present a detailed analysis during different stages of axolotl development, and we show that despite previous beliefs the axolotl does regenerate the lens, however, only during a limited time after hatching. We have found that starting at stage 44 (forelimb bud stage lens regeneration is possible for nearly two weeks. Regeneration occurs from the iris but, in contrast to the newt, regeneration can be elicited from either the dorsal or the ventral iris and, occasionally, even from both in the same eye. Similar studies in the zebra fish concluded that lens regeneration is not possible. Conclusions Regeneration of the lens is possible in the axolotl, but differs from both frogs and newts. Thus the axolotl iris provides a novel and more plastic strategy for lens regeneration.

  14. Frozen allogeneic human epidermal cultured sheets for the cure of complicated leg ulcers.

    Science.gov (United States)

    Bolívar-Flores, Y J; Kuri-Harcuch, W

    1999-08-01

    Skin ulcers due to venous stasis or diabetes are common among the elderly and are difficult to treat. Repeated applications of cell-based products have been reported to result in cure or improvement of leg ulcers of small size in a fraction of patients. To examine the effects of frozen human allogeneic epidermal cultures for the treatment of acute and chronic ulcers. We treated a series of 10 consecutive patients with leg ulcers of different etiology and duration with frozen human allogeneic epidermal cultures stored frozen and thawed for 5-10 minutes at room temperature before application. Three patients had ulcers with exposed Achilles or extensor tendon. The ulcers treated were as large as 160 cm2 in area and of up to 20-years' duration. After preliminary preparation of the wounds by debridement to remove necrotic tissue and application of silver sulfadiazine to control infection, thawed cultures were applied biweekly from 2 to 15 times depending on the size and complexity of the ulcer. All ulcers healed, including those with tendon exposure. After the first few applications, granulation tissue formed in the ulcer bed and on exposed tendons, and epidermal healing took place through proliferation and migration of cells from the margins of the wound. The time required for complete healing ranged from 1 to 31 weeks after the first application. The use of frozen human allogeneic epidermal cultures is a safe and effective treatment for venous or diabetic ulcers, even those with tendon exposure. It seems possible that any leg ulcer will be amenable to successful treatment by this method.

  15. Diurnal Alterations of Refraction, Anterior Segment Biometrics, and Intraocular Pressure in Long-Time Dehydration due to Religious Fasting.

    Science.gov (United States)

    Baser, Gonen; Cengiz, Hakan; Uyar, Murat; Seker Un, Emine

    2016-01-01

    To investigate the effects of dehydration due to fasting on diurnal changes of intraocular pressure, anterior segment biometrics, and refraction. The intraocular pressures, anterior segment biometrics (axial length: AL; Central corneal thickness: CCT; Lens thickness: LT; Anterior chamber depth: ACD), and refractive measurements of 30 eyes of 15 fasting healthy male volunteers were recorded at 8:00 in the morning and 17:00 in the evening in the Ramadan of 2013 and two months later. The results were compared and the statistical analyses were performed using the Rstudio software version 0.98.501. The variables were investigated using visual (histograms, probability plots) and analytical methods (Kolmogorov-Smirnov/Shapiro-Wilk test) to determine whether or not they were normally distributed. The refractive values remained stable in the fasting as well as in the control period (p = 0.384). The axial length measured slightly shorter in the fasting period (p = 0.001). The corneal thickness presented a diurnal variation, in which the cornea measured thinner in the evening. The difference between the fasting and control period was not statistically significant (p = 0.359). The major differences were observed in the anterior chamber depth and IOP. The ACD was shallower in the evening during the fasting period, where it was deeper in the control period. The diurnal IOP difference was greater in the fasting period than the control period. Both were statistically significant (p = 0.001). The LT remained unchanged in both periods. The major difference was shown in the anterior chamber shallowing in the evening hours and IOP. Our study contributes the hypothesis that the posterior segment of the eye is more responsible for the axial length alterations and normovolemia has a more dominant influence on diurnal IOP changes.

  16. Increased incidence of murine graft-versus-host disease after allogeneic bone marrow transplantation by previous infusion of syngeneic bone marrow cells

    International Nuclear Information System (INIS)

    Waer, M.; Ang, K.K.; van der Schueren, E.; Vandeputte, M.

    1984-01-01

    Different groups of BALB/c mice received supralethal total-body irradiation (TBI; 8.5 Gy, day 0). When 30 x 10(6) allogeneic (C57B1) bone marrow (BM) cells were infused with or without 10 x 10(6) syngeneic (BALB/c) bM cells on day 1, many animals (60%) died from graft-versus-host disease (GVHD). Typing of peripheral blood leukocytes for donor antigens showed that, respectively, 22/22 and 17/21 of the mice in both groups became chimeric. When syngeneic bone marrow was given on day 1 and allogeneic bone marrow on day 2 after TBI, a similar number of animals (21/23) became chimeric, but GVHD occurred more frequently in this group (25/26 mice, P less than 0.01). When the syngeneic bone marrow cells were replaced by spleen cells, or when the transplantation of allogeneic bone marrow was delayed till days 3 or 6 after TBI, almost all mice rejected the allogeneic BM graft and became long-term survivors. BALB/c mice receiving 30 x 10(6) C57B1 BM cells after 17 daily fractions of 0.2 Gy of total lymphoid irradiation (TLI), showed a high incidence of chimerism (15/17) and in none of the latter animals was GVHD observed. Despite the high incidence of GVHD in the mice receiving allogeneic BM after TBI and syngeneic BM transplantation, as compared with mice prepared with TLI which do not develop GVHD, suppressor cells were as easily induced after TBI and syngeneic BM transplantation as after TLI

  17. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric powers...

  18. Computer optimization of retarding lens systems for ESCA spectrometers

    International Nuclear Information System (INIS)

    Wannberg, B.; Skoellermo, A.

    1977-01-01

    The performance of four-element electrostatic lenses as retarding systems between source and analyzer in ESCA spectrometers is calculated. The potential distribution in the lens is defined by an axial potential of the type phi(z)=V 0 +Σ(Vsub(i)-Vsub(i-1))/2 - tanh (ω/asub(i)(z-zsub(i))). For a given general shape of the lens and a given retardation ratio, the potentials of the two middle electrodes are fitted to give a paraxial image with a prescribed magnification at the exit slit of the lens system. The equipotential surfaces forming the electrodes are found by calculating the potential in an off-axis point, using the series expansion. All third-order geometrical and first-order chromatic aberrations of the lenses are calculated and used together with the second-order aberrations of the analyzer to calculate optimum dimensions of the lens elements and of the emittance-defining slits. A computer program, of which one part calculates the lens properties and one the properties of the entire system lens-analyzer, is described. Two lens systems are presented in some detail. The first one is intended for use with a hemispherical electrostatic analyzer. The angular acceptance is here defined by an aperture stop inside the lens. In this system, the image position and magnification can be kept constant for retardation ratios at least between 1:2 and 60:1, with moderate potentials on the middle electrodes. The second lens system is designed for a magnetic spectrometer of the π√2-type. Here, the central trajectory in the lens is slightly curved by the magnetic field, and the angular acceptance is defined by a baffle after the lens. This system is optimized for a constant retardation ratio of 5:1. (Auth.)

  19. Candidate gravitational microlensing events for future direct lens imaging

    International Nuclear Information System (INIS)

    Henderson, C. B.; Gould, A.; Gaudi, B. S.; Park, H.; Han, C.; Sumi, T.; Koshimoto, N.; Udalski, A.; Tsapras, Y.; Bozza, V.; Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K.; Bennett, D. P.; Bond, I. A.; Ling, C. H.; Botzler, C. S.; Freeman, M.; Fukui, A.

    2014-01-01

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr –1 . Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  20. Candidate gravitational microlensing events for future direct lens imaging

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C. B.; Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Park, H.; Han, C. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Sumi, T.; Koshimoto, N. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Bozza, V. [Department of Physics, University of Salerno, I-84084 Fisciano (Italy); Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A.; Ling, C. H. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland 0745 (New Zealand); Botzler, C. S.; Freeman, M. [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Fukui, A. [School of Chemical and Physical Sciences, Victoria University, Wellington 6140 (New Zealand); Collaboration: MOA Collaboration; OGLE Collaboration; μFUN Collaboration; RoboNet Collaboration; and others

    2014-10-10

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr{sup –1}. Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  1. Antifungal prophylaxis with fluconazole in allogeneic stem cell transplantation recipients who had prior invasive aspergillosis with subsequent complete resolution by computed tomography.

    Science.gov (United States)

    Akahoshi, Yu; Kimura, Shun-Ichi; Gomyo, Ayumi; Hayakawa, Jin; Tamaki, Masaharu; Harada, Naonori; Kusuda, Machiko; Kameda, Kazuaki; Ugai, Tomotaka; Wada, Hidenori; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Sato, Miki; Terasako-Saito, Kiriko; Kikuchi, Misato; Nakasone, Hideki; Kako, Shinichi; Kanda, Yoshinobu

    2018-04-01

    Consensus has yet to be reached regarding secondary prophylaxis in allogeneic hematopoietic stem cell transplantation (HSCT) with a complete resolution of invasive aspergillosis (IA) confirmed by chest computed tomography (CT). We retrospectively evaluated the feasibility of antifungal prophylaxis with fluconazole in allogeneic HSCT recipients who had previously developed IA which showed complete resolution as confirmed by chest CT before HSCT. Consecutive adult patients who underwent allogeneic HSCT at our institution and who had received fluconazole as systemic antifungal prophylaxis from June 2007 to January 2015 were included. We compared the clinical outcomes between patients with a past history of IA who showed a complete resolution of chest CT abnormalities (n = 13) and those without a previous history of IA (n = 137). The cumulative incidence of proven or probable IA was 8.8% in the group without a past history of IA and 0.0% in the group with a past history of IA (p = .268). The cumulative incidence of proven or probable invasive fungal disease (IFD) within 100 days after allogeneic HSCT was 10.9% in the group without a past history of IA and 15.4% in the group with a past history of IA (p = .647). Fluconazole was switched to anti-mould agents in two-thirds of the patients in each group by day 100 after HSCT. Fluconazole was confirmed to be an acceptable prophylactic agent early after allogeneic HSCT in appropriately selected patients.

  2. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  3. Optofluidic lens actuated by laser-induced solutocapillary forces

    Science.gov (United States)

    Malyuk, A. Yu.; Ivanova, N. A.

    2017-06-01

    We demonstrate an adaptive liquid lens controlled by laser-induced solutocapillary forces. The liquid droplet serving as a lens is formed in a thin layer of binary liquid mixture by surface tension driven flows caused by the thermal action of laser irradiation. The shape of droplet, its aperture and the focal length are reversibly changed without hysteresis by varying the intensity of the laser beam. The focal length variation range of the droplet-lens lies in between infinity (a flat layer) to 15 mm (a curved interface). The droplet-lens is capable to adjust the in-plane lateral position in response to a displacement of the laser beam. The proposed laser controlled droplet-lens will enable to develop smart liquid optical devices, which can imitate the accommodation reflex and pupillary light reflex of the eye.

  4. The Sloan Lens ACS Survey. I. A large spectroscopically selected sample of massive early-type lens galaxies

    NARCIS (Netherlands)

    Bolton, AS; Burles, S; Koopmans, LVE; Treu, T; Moustakas, LA

    2006-01-01

    The Sloan Lens ACS (SLACS) Survey is an efficient Hubble Space Telescope (HST) Snapshot imaging survey for new galaxy-scale strong gravitational lenses. The targeted lens candidates are selected spectroscopically from the Sloan Digital Sky Survey (SDSS) database of galaxy spectra for having multiple

  5. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  6. Anterior ankle arthroscopy, distraction or dorsiflexion?

    Science.gov (United States)

    de Leeuw, Peter A J; Golanó, Pau; Clavero, Joan A; van Dijk, C Niek

    2010-05-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, whereas in ankle distraction the anterior neurovascular bundle is pulled tight towards the joint, thereby decreasing the safe anterior working area. Six fresh frozen ankle specimens, amputated above the knee, were scanned with computed tomography. Prior to scanning the anterior tibial artery was injected with contrast fluid and subsequently each ankle was scanned both in ankle dorsiflexion and in distraction. A special device was developed to reproducibly obtain ankle dorsiflexion and distraction in the computed tomography scanner. The distance between the anterior border of the inferior tibial articular facet and the posterior border of the anterior tibial artery was measured. The median distance from the anterior border of the inferior tibial articular facet to the posterior border of the anterior tibial artery in ankle dorsiflexion and distraction was 0.9 cm (range 0.7-1.5) and 0.7 cm (range 0.5-0.8), respectively. The distance in ankle dorsiflexion significantly exceeded the distance in ankle distraction (P = 0.03). The current study shows a significantly increased distance between the anterior distal tibia and the overlying anterior neurovascular bundle with the ankle in a slightly dorsiflexed position as compared to the distracted ankle position. We thereby conclude that the distracted ankle position puts the neurovascular structures more at risk for iatrogenic damage when performing anterior ankle arthroscopy.

  7. Gravitational lens effect and pregalactic halo objects

    International Nuclear Information System (INIS)

    Bontz, R.J.

    1979-01-01

    The changes in flux, position, and size of a distant extended (galaxy, etc.) source that result from the gravitational lens action of a massive opaque object are discussed. The flux increase is described by a single function of two parameters. One of these parameters characterizes the strength of the gravitational lens, the other describes the alignment of source and lens object. This function also describes the relative intensity of the images formed by lens. ( A similar formalism is discussed by Bourassa et al. for a point source). The formalism is applied to the problem of the galactic halo. It appears that a massive (10 1 2 M/sub sun/) spherical halo surrounding the visible part of the galaxy is consistent with the observable properties of extragalactic sources

  8. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  9. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  10. RENAL ALLOGENEIC TRANSPLANTATION IN PATIENT WITH HAEMOPHILIA B

    Directory of Open Access Journals (Sweden)

    N. V. Purlo

    2014-01-01

    Full Text Available We report the case of successful renal allogeneic transplantation and treatment in a 56-year-old patient with haemophilia B at Hematology Research Center. He has received replacement therapy by factor IX since 2010. The transplant is marked with good renal function during 13 post-transplant months without episodes of rejection or bleeding complications. The complicated surgical interventions are possible in patients with haemophilia В аnd end-stage chronic renal failure in the presence of replacement therapy of IX factor for the purpose of achievement of optimum hemostasis.

  11. Transplantation of islet cells across major histocompatibility barriers after total lymphoid irradiation and infusion of allogeneic bone marrow cells

    International Nuclear Information System (INIS)

    Britt, L.D.; Scharp, D.W.; Lacy, P.E.; Slavin, S.

    1982-01-01

    Diabetic Lewis rats (AgB1/L) were evaluated as recipients of allogeneic Wistar-Furth (AgB2/2) isolated adult islets without the use of standard recipient immunosuppression. One group was treated with fractionated total lymphoid irradiation (TLI) and Wistar-Furth bone marrow cell reconstitution to proven chimerism prior to islet transplantation. This group returned to a prediabetic state following Wistar-Furth islet transplantation without any evidence of rejection for 100 days posttransplant. A second group of Lewis rats received only TLI without bone marrow treatment. They gave a varying result following islet transplantation with one recipient showing evidence of prolonged islet survival. A third chimeric control group did not receive isolated islets and did not alter their diabetic state. A fourth group was not given TLI nor donor bone marrow cells and uniformly rejected their allogeneic islets by 7 days. Thus, allogeneic adult islets will survive across major rat histocompatibility barriers using TLI and donor bone marrow chimerism as the only form of immunosuppression

  12. Anterior ankle arthroscopy, distraction or dorsiflexion?

    OpenAIRE

    de Leeuw, P.A.J.; Golanó, P.; Clavero, J.A.; van Dijk, C.N.

    2010-01-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, where...

  13. The partial coherence modulation transfer function in testing lithography lens

    Science.gov (United States)

    Huang, Jiun-Woei

    2018-03-01

    Due to the lithography demanding high performance in projection of semiconductor mask to wafer, the lens has to be almost free in spherical and coma aberration, thus, in situ optical testing for diagnosis of lens performance has to be established to verify the performance and to provide the suggesting for further improvement of the lens, before the lens has been build and integrated with light source. The measurement of modulation transfer function of critical dimension (CD) is main performance parameter to evaluate the line width of semiconductor platform fabricating ability for the smallest line width of producing tiny integrated circuits. Although the modulation transfer function (MTF) has been popularly used to evaluation the optical system, but in lithography, the contrast of each line-pair is in one dimension or two dimensions, analytically, while the lens stand along in the test bench integrated with the light source coherent or near coherent for the small dimension near the optical diffraction limit, the MTF is not only contributed by the lens, also by illumination of platform. In the study, the partial coherence modulation transfer function (PCMTF) for testing a lithography lens is suggested by measuring MTF in the high spatial frequency of in situ lithography lens, blended with the illumination of partial and in coherent light source. PCMTF can be one of measurement to evaluate the imperfect lens of lithography lens for further improvement in lens performance.

  14. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  15. Nonmyeloablative and reduced-intensity conditioning for allogeneic hematopoietic stem cell transplantation: a clinical review.

    Science.gov (United States)

    Pollack, Seth M; O'Connor, Thomas P; Hashash, Jana; Tabbara, Imad A

    2009-12-01

    Allogeneic hematopoietic stem cell transplantation provides many patients, with hematological and malignant diseases, hope of remission and in some cases cure. Because the toxicities of this approach are severe, its use has been limited to younger healthier patients. Nonmyeloablative and reduced intensity conditioning regimens depend more on donor cellular immune effects and less on the cytotoxic effects of the conditioning regimen to eradicate the underlying disease. This approach is based on the induction of host tolerance to donor cells followed by the administration of scheduled donor T-lymphocytes infusions. Accumulated clinical data have been encouraging, and prospective studies are underway to compare this approach to conventional myeloablative allogeneic stem cell transplantation with regard to outcome, durability of responses, effects on the immune system, and the consequences of late complications such as chronic graft-versus-host disease.

  16. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  17. Effect of contact lens use on Computer Vision Syndrome.

    Science.gov (United States)

    Tauste, Ana; Ronda, Elena; Molina, María-José; Seguí, Mar

    2016-03-01

    To analyse the relationship between Computer Vision Syndrome (CVS) in computer workers and contact lens use, according to lens materials. Cross-sectional study. The study included 426 civil-service office workers, of whom 22% were contact lens wearers. Workers completed the Computer Vision Syndrome Questionnaire (CVS-Q) and provided information on their contact lenses and exposure to video display terminals (VDT) at work. CVS was defined as a CVS-Q score of 6 or more. The covariates were age and sex. Logistic regression was used to calculate the association (crude and adjusted for age and sex) between CVS and individual and work-related factors, and between CVS and contact lens type. Contact lens wearers are more likely to suffer CVS than non-lens wearers, with a prevalence of 65% vs 50%. Workers who wear contact lenses and are exposed to the computer for more than 6 h day(-1) are more likely to suffer CVS than non-lens wearers working at the computer for the same amount of time (aOR = 4.85; 95% CI, 1.25-18.80; p = 0.02). Regular contact lens use increases CVS after 6 h of computer work. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  18. The effect of compliance on contact lens case contamination.

    Science.gov (United States)

    Tilia, Daniel; Lazon de la Jara, Percy; Zhu, Hua; Naduvilath, Thomas J; Holden, Brien A

    2014-03-01

    To determine the efficacy of written instructions on contact lens case hygiene and to quantify the effect of noncompliance on contact lens case contamination. Data were retrospectively analyzed from 16 prospective, 3-month daily-wear studies during which six commercially available silicone hydrogel contact lenses and seven lens care solutions (LCS) were tested following a similar protocol. Verbal instructions regarding case hygiene (rinse case with LCS, not tap water) were given in nine studies, while the same instructions were given verbally and in written format in seven studies. A survey on contact lens, LCS, and lens case hygiene was completed at 1- and 3-month visits and compliance with case hygiene instructions was determined. Regular contact lens cases were used for 1 month and collected for microbial analysis at the 1- and 3-month visits. The rate of case contamination and the types of microbes contaminating cases were evaluated. Participants given verbal and written instructions were more likely to be compliant with case hygiene instructions than those just given verbal instructions (odds ratio [OR]: 2.19, p hygiene can be improved by effective communication of instructions. Contact lens wearers should be actively discouraged from rinsing contact lens cases with tap water because of the increased risk of GNB contamination.

  19. Lens dislocation has a possible relationship with laser iridotomy

    Directory of Open Access Journals (Sweden)

    Mutoh T

    2012-12-01

    Full Text Available Tetsuya Mutoh,1,2 Kevin F Barrette,2 Yukihiro Matsumoto,1 Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya City, Saitama, Japan; 2Department of Ophthalmology, Boston University School of Medicine, Boston, MA, USAAbstract: We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 months following laser iridotomy. All patients were male and two eyes were complicated with acute primary angle closure glaucoma preoperatively. Case 1 showed bilateral lens dislocation, while cases 2 and 3 involved unilateral lens dislocation. Cases 2 and 3 showed lenses completely dislocated into the vitreous cavity. All cases needed lens removal and scleral fixation of intraocular lenses. Final visual acuity was 1.2 in all cases. We suspect that laser iridotomy may induce localized zonular dialysis that results in progressive zonular weakness, leading to lens dislocation.Keywords: lens dislocation, laser iridotomy, primary angle closure glaucoma

  20. Lens transmission measurement for an absolute radiation thermometer

    International Nuclear Information System (INIS)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-01-01

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10 −3 at 633 nm and 900 nm, respectively